WorldWideScience

Sample records for densitometry

  1. Bone densitometry

    DEFF Research Database (Denmark)

    Ravn, Pernille; Alexandersen, P; Møllgaard, A

    1999-01-01

    The bisphosphonates have been introduced as alternatives to hormone replacement therapy (HRT) for the treatment and prevention of postmenopausal osteoporosis. The expected increasing application in at clinical practice demands cost-effective and easily handled methods to monitor the effect on bone....... The weak response at the distal forearm during antiresorptive treatment has restricted the use of bone densitometry at this region. We describe a new model for bone densitometry at the distal forearm, by which the response obtained is comparable to the response in other regions where bone densitometry...... is much more expensive and technically complicated. By computerized iteration of single X-ray absorptiometry forearm scans we defined a region with 65% trabecular bone. The region was analyzed in randomized, double-masked, placebo- controlled trials: a 2-year trial with alendronate (n = 69), a 1-year...

  2. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Lampmann, L.E.H.

    1982-01-01

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  3. Nuclear medicine and densitometry

    International Nuclear Information System (INIS)

    Mazess, R.B.; Wahner, H.M.

    1988-01-01

    Several reports and books over the past decade have summarized bone measurement methods. This chapter serves as an update on those with particular reference to nuclear medicine approaches to bone density and skeletal uptake. Bone densitometry approaches include singe-photon absorptiometry(SPA) and dual-photon absortiometry neutron activation (DPA) of calcium, Compton scattering, ultrasound measurements and uptake of diphosphonates. Of these only SPA and DPA are used clinically; the other methods are largely experimental or investigational. Radiographic morphometry, radiographic indices, and X-ray QCT are dealt with

  4. Dual modality densitometry

    International Nuclear Information System (INIS)

    Tjugum, Stein-Arild

    2003-01-01

    Different measurement principles and design issues for gamma-ray densitometry for pipe flow are investigated. The dual modality densitometry (DMD) principle for salinity measurement and flow regime identification by multibeam densitometry are tested and verified. The measurement principles are implemented in a compact instrument design with low energy source and compact detectors. The DMD principle is experimentally verified for 3 inch and 2 inch pipes. These measurements are done on homogenous brine/gas mixtures. Both salinity independent GVF measurements and salinity measurements are obtained. The standard deviation of the salinity measurements are about 2 percent. This measurement inaccuracy is mainly caused by inhomogeneity in the liquid/gas distribution, and measurements are thus sensitive to changes in the flow regime. Models for the generation of scattered radiation are developed, and these have been used in the data-analysis and for producing special sensitivity maps for the generation of scattered radiation. The models are a useful tool for further development of the DMD principle. The work on multibeam gamma-ray densitometry has shown that flow regimes can be identified with as few as two detectors. This is verified in the flow-loop tests. Unambiguous flow regime identification will often require that the multibeam measurements are combined with other flow measurements. With a higher number of detectors more detailed information is found, and from the 9-beam measurements with the University of Bergen (UoB) gamma-ray tomography different flow regimes could clearly be identified from time series plots of the data. A laboratory prototype compact gamma-ray densitometer, the MiniGamma, has been built up and tested. Both the DMD measurement principle and the multibeam arrangement for flow regime identification are implemented in the instrument, and are successfully tested. The detector-types tested are CdZnTe semiconductor detectors, a miniature scintillation

  5. New radiochroic film densitometry system

    International Nuclear Information System (INIS)

    Tran, T.; Freeman, N.; Johnston, P.

    2004-01-01

    Full text: The advantages of radiochromic film in radiation dosimetry are well known. They include dosimetry with high spatial resolution, response less dependent on incident beam energy than common radiotherapy films (such as the Kodak XV films), tissue equivalence and the ability to be handled and developed in room light. This study entails the design and testing of a new radiochromic densitometry system. The system consists of a single light emitting diode (LED), opaque 'diffuser' and digital camera. Customised software was developed to analyse images obtained from the digital camera. Standard characteristics of a commercially available super bright red LED (peak wavelength 625nm) was analysed in order to determine the voltage, current and intensity settings. Various methods in diffusing the single LED light source were investigated and it was determined that an opaque transmission 'diffuser' was the best alternative. While the intensity of the LED was kept constant, the digital camera exposure times were varied in order to determine a setting which would produce the best image exposure. The system was designed and built and preliminary tests were carried using the standard radiochromic film GafChromic MD-55-2. LED current vs. voltage curves were characteristically exponential for positive voltage. Studies into LED intensity versus camera exposure produced an unexpected result. At high exposures the camera saturates and if even higher exposures are used the LED intensity apparently decreases. This was thought to be due to the pixels in the charge couple device (CCD) saturating and eventually electronically 'bleeding' into adjacent pixels. Using the opaque transmission 'diffuser' enabled successful use of the single LED light producing an area of homogenous light intensity in which images of radiochromic films can be obtained. Preliminary results from radiochromic film characteristic studies show no unusual results. The single LED, diffuser and digital camera

  6. Diagnosis of osteoporosis through two photon densitometry

    International Nuclear Information System (INIS)

    Marone, M.M.S.; Lewin, S.; Bianco, A.C.; Correa, P.H.S.

    1989-01-01

    Osteoporosis is often diagnosed after fracture occurrence, when therapy is less effective. The dual photon densitometry has been the proposed method for osteoporosis early diagnosis. In the present study is presented our experience on the lumbar vertebral and femoral neck bone mass measurement by utilizing a Lunar DP-3 densitometer in normal young 82 volunteers and 103 women with radiologically and clinically diagnosed osteoporosis. The values found in osteoporotical patients were significantly lower when compared to those normals either in lumbar vertebrae (L2-L4) or in the femoral neck. The method's coefficient of variation was [pt

  7. Role of bone photonic densitometry in uremic osteodystrophy

    International Nuclear Information System (INIS)

    Specchi Bighi, E.; Baldelli, S.; Argalia, G.

    1987-01-01

    The aim of this investigation is to evaluate the role of bone photonic densitometry in uremic osteodystrophy. Bone mineral contenent (BMC) and bone density (BD) have been measured in 80 hemodialyzed patients by double photonic emission densitometry. Photonic densitometry shows an higher sensibility to quantitative changes in bone mineral contenent than metacarpal index (IM). Photonic densitometry is unable to differentiate osteoporosis from osteomalacia; this differential diagnosis can be obtained by radiological analysis: low BD and low IM means osteoporosis, low BD and resorptive changes in cortical bone means osteomalacia and/or hyperparathyroidism. Photonic densitometry is particulary suitable for uremic osteodystrophy follow-up because of its easy ripetibility and innocuousness and for its close correlation with iPTH variations

  8. Bone densitometry with the computer tomograph

    International Nuclear Information System (INIS)

    Weiss, T.

    1978-01-01

    This work tests the usefulness of the EMI head scanner MARK I for a quantitative detection of ossary mineral content. Twenty-three concentration levels of a aqueous K 2 HPO 4 -solution were positioned by means of a special clamping device at the EMI-scanner and examined at tubevoltages of 100, 120 and 140 kV. This produces an almost linear dependence between CT-unit and sample concentration, whereby it shows that the measured special element densities of samples with the same densities vary in dependence with the voltage. The examination of an anotomical fore-arm preperate served as a statement for the reproductability of computer tomographic densitometry at non-moving biological objects. The test of reproductability of bone densitometry measurements under clinical conditions was made on the occation of the six time examinations of the right hand fore-arm bone of a young dummy. Furthermore densitometric examination were made at the fore-arm shelton of 40 long-time dialysis patients in the age levels between 17 and 67 years. The reproductability of the technique presented here is at least not better with the EMI-head-scanner MARK I used here. A change is possible by using the new whole body tomographs. (orig./MG) [de

  9. Bone densitometry in dogs using gamma radiation

    International Nuclear Information System (INIS)

    Oliveira, A.L.B.; Costa, V.E.; Rezende, M.A.; Grossklauss, D.B.B.F.; Oliveira, T.B.

    2010-01-01

    Full text. The purpose of this work came from the possibility of joining similar methodologies for determination of density, used in different areas, and provide more precise values of bone density by analyzing the mass attenuation coefficient. For over 20 years, The Applied Physics Laboratory, Department of Physics and Biophysics, IBB- UNESP, Botucatu campus, has been working in the determination of density in different areas, using the methods of immersion and gamma radiation attenuation. The results presented have excellent precision, due to the facility in obtaining and preparing samples, coupled to the large experience in the area. This study aims to determine the bone density of samples of mongrel dogs (dogs without defined breed) by the immersion method; to determine the mass attenuation coefficient of bones samples of mongrel dogs with a gamma radiation source; to discuss and to evaluate the methodological aspects involved in the optic densitometry used nowadays, presenting its advantages and disadvantages and, finally, to examine the effect of animal weight, age and sex on bone densitometry of medium-sized dogs. For this study, we use upper limbs samples, at the joint region humerus-radio-ulnar of after death mongrel dogs, assigned by the Department of Pathology, Faculty of Animal Science and Veterinary Medicine (UNESP-Botucatu) and by the Kennel of the city of Araras, Sao Paulo. This work is performed in three stages. In the first step is determined the density by the method of immersion in water, in the second step, is obtained the mass coefficient attenuation and, finally, in the third step are discussed the implemented methods and evaluate the density bone samples to establish correlations with the age, weight and sex parameters of each group of animals. Based on this methodology , we can find the average value for the mass attenuation coefficient of gamma radiation with energy 59,6, find variations in the values of bone densitometry in the same bone

  10. Intrinsic densitometry: In-plant evaluation

    International Nuclear Information System (INIS)

    Nishida, K.; Kurosawa, A.; Masui, J.; Hsue, S.T.

    1994-11-01

    A measurement of the plutonium concentration in a sample is always necessary for nuclear material control and accounting. This report describes the testing of the intrinsic densitometry (ID) technique for implant applications. The authors found that the ID method can determine the plutonium concentrations to between 2 and 3% at concentrations of 100 g/l to 200 g/l with quartz cells and a measurement time of 3600 s. The precision can be improved to 1 to 2% with a higher counting rate. The authors also found that nitric acid concentration and the impurity level of uranium in the product plutonium solution do not affect the concentration measurement. When this technique is applied to plutonium solutions in stainless steel pipes, they found that similar precision in plutonium concentration can be achieved using a high-count-rate detector. The precision, however, is reduced with aged plutonium solutions

  11. Blood flow determinations utilizing digital densitometry

    International Nuclear Information System (INIS)

    Lois, F.; Mankovich, N.J.; Gomes, A.S.

    1987-01-01

    A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512 2 and 1024 2 mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024 2 and 512 2 imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024 2 matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512 2 and 1024 2 imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512 2 or 1024 2 imaging. The increased accuracy in vessel size determination with 1024 2 imaging makes this high resolution system potentially perferable to determine absolute blood flow. (orig.)

  12. Whole-lung densitometry versus visual assessment of emphysema

    International Nuclear Information System (INIS)

    Cavigli, Edoardo; Orlandi, Ilaria; Grassi, Luca; Farfalla, Carmela; Mascalchi, Mario; Camiciottoli, Gianna; Meoni, Eleonora; Pistolesi, Massimo; Diciotti, Stefano; Spinelli, Cheti; Falaschi, Fabio

    2009-01-01

    We compared whole-lung densitometry with visual evaluation of pulmonary emphysema. Thirty patients with chronic obstructive pulmonary disease underwent multi-detector CT (150 mAs and 0.75 collimation) with double reconstruction: thick (5-mm) slices with smooth filter for whole-lung densitometry and thin (1 mm) slices with sharp filter for visual assessment (one of every ten slices). Densitometry and visual assessment were performed by three operators each, and the time required for assessment, the inter-observer agreement and the correlation with the results of the diffusion capacity of carbon monoxide (DL CO ) in the same patients were computed. The average time for densitometry (8.49 ± 0.13 min) was significantly longer (p CO with relative area at -960 and -970 Hounsfield units (HU) (both r = -0.66) and of the first percentile point of lung density (r = 0.66) were slightly stronger than that of the visual score (r = -0.62). Densitometry should be preferred to visual assessment because it enables a more reproducible evaluation of the extent of pulmonary emphysema, which can be carried out on the entire lung in a reasonable amount of time. (orig.)

  13. Edge detection versus densitometry for assessing coronary stenting quantitatively

    NARCIS (Netherlands)

    B.H. Strauss (Bradley); Y. Juilliere; B.J.W.M. Rensing (Benno); J.H.C. Reiber (Johan); P.W.J.C. Serruys (Patrick)

    1991-01-01

    textabstractThe optimal method used to analyze quantitatively the immediate angiographic results of coronary stenting in the coronary arteries has not been studied. Accordingly, minimal luminal cross-sectional area was determined by 2 methods, edge detection and densitometry, in 19 patients who

  14. Assessment of regional progression of pulmonary emphysema with CT densitometry

    DEFF Research Database (Denmark)

    Bakker, M Els; Putter, Hein; Stolk, Jan

    2008-01-01

    BACKGROUND: Lung densitometry is an effective method to assess overall progression of emphysema, but generally the location of the progression is not estimated. We hypothesized that progression of emphysema is the result of extension from affected areas toward less affected areas in the lung....... To test this hypothesis, a method was developed to assess emphysema severity at different levels in the lungs in order to estimate regional changes. METHODS: Fifty subjects with emphysema due to alpha(1)-antitrypsin deficiency (AATD) [AATD deficiency of phenotype PiZZ (PiZ) group] and 16 subjects...... with general emphysema (general emphysema without phenotype PiZZ [non-PiZ] group) were scanned with CT at baseline and after 30 months. Densitometry was performed in 12 axial partitions of equal volumes. To indicate predominant location, craniocaudal locality was defined as the slope in the plot of densities...

  15. Bone density determination using I125 densitometry with idiopathic scoliosis

    International Nuclear Information System (INIS)

    Weinberger, N.

    1984-01-01

    Based on the assumption that radiographs from patients with idiopathic scoliosis show osteoporotic changes in the curved area, investigation with I 125 -densitometry were made, and specifically with measurement points at the ulna and the calcaneus. A difference in the bone density between patients with scoliosis and normal controls could not be proven. The mineral-salt content of the scoliosis patients lay on the average 6.5 to 9.3% lower than the normal controls. No relation could be found between the degree of curvature of the scoliosis and the peripheral bone density, from which it can be concluded that no generalized mineral-salt deficiency exists. Radiographs show only local changes (photo densitometry, computed tomography). (TRV) [de

  16. Nuclear safeguards applications of energy-dispersive absorption edge densitometry

    International Nuclear Information System (INIS)

    Russo, P.A.; Hsue, S.T.; Langner, D.G.; Sprinkle, J.K. Jr.

    1980-01-01

    The principles and techniques of absorption edge densitometry in the energy-dispersive mode are summarized as they apply to the nondestructive assay of special nuclear materials. Five existing field instruments, designed for special nuclear materials accounting measurements, are described. Results of the testing of these instruments as well as recent laboratory results are used to define the capabilities of the technique for special nuclear materials accounting. Possibilities for future applications are reviewed. 14 figures

  17. Knowledge about osteoporosis prevention among women screened by bone densitometry

    Directory of Open Access Journals (Sweden)

    Mariola Janiszewska

    2016-07-01

    Full Text Available Introduction : Osteoporosis is an illness characterized by the handicapped endurance of the bones, causing an increased risk of fracture. Aim of the study was to establish the level of knowledge about osteoporosis prevention among women screened by bone densitometry and to answer the question whether the level of knowledge is dependent on socio-demographic factors. Material and methods: The research was realized by means of a survey method, a poll technique in 2014. The study involved 292 women aged 51-83. The examined women were patients undergoing bone densitometry in the healthcare centres in Lublin. The osteoporosis knowledge test (OKT, revised 2011 by Phyllis Gendler was used as a research tool. Gathered material was subject to descriptive and statistical analysis. Tukey’s test, t-Student test and variance analysis (ANOVA were all applied. A statistical significance level was set at  = 0.05. Results and conclusions : Respondents presented the basic exercise knowledge (M = 9.97 and low knowledge concerning risk factors, screening and treatment of osteoporosis (M = 7.87. The calcium knowledge remained on an average level (M = 14.03. Better educated women, city inhabitants as well as women having very good or good social and welfare conditions showed a significantly higher level of knowledge about osteoporosis prevention. Even women undergoing bone densitometry examination present insufficient knowledge about osteoporosis prevention.

  18. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction.

    Science.gov (United States)

    Garzón, Nuria; Poyales, Francisco; Illarramendi, Igor; Mendicute, Javier; Jáñez, Óscar; Caro, Pedro; López, Alfredo; Argüeso, Francisco

    2017-12-01

    To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p  0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.

  19. Corneal Densitometry as a Tool to Measure Epithelial Ingrowth After Laser In Situ Keratomileusis.

    Science.gov (United States)

    Adran, Daniel; Vaillancourt, Louis; Harissi-Dagher, Mona; Kruh, Jonathan N; Syed, Zeba A; Robinson, Steven; Melki, Samir

    2017-04-01

    This study evaluates the correlation between corneal densitometry and epithelial ingrowth (EI) after laser in situ keratomileusis (LASIK). Corneal densitometry of 3 patients who developed EI after LASIK was measured with the Oculus Pentacam. Corneal densitometry readings of each patient were obtained preoperatively and postoperatively after ingrowth was discovered. Densitometry was recorded at the central nest of opacity and at the leading edges of EI. For all patients, the most severe stages of EI observed on slit-lamp photographs correlated with the highest densitometry readings, with peak densitometry ranging from 73.3 to 95.1. These values were much higher than preoperative densitometry readings, which ranged from 21.8 to 27.2. In 2 cases, the Pentacam densitometry map revealed progression of EI toward the visual axis that was only faintly detectable or not detectable at all on the corresponding slit-lamp photographs. Corneal densitometry seems to be an objective measure of the severity and progression of EI after LASIK.

  20. Changes in distribution of bone densitometry equipment from 1996 to 2006 in Japan.

    Science.gov (United States)

    Yamauchi, Hirose; Fukunaga, Masao; Nishikawa, Akira; Orimo, Hajime

    2010-01-01

    Many types of bone densitometry equipment are available in Japan, but the numbers of such machines and the numbers of institutions that offer bone densitometry have not been clarified. We analyzed the data from annual surveys conducted by the Japan Osteoporosis Foundation from 1996 to 2006, and we obtained the following results on the use of densitometry equipment: (1) In 1996 there were 6,687 units of bone densitometry equipment in 6,483 institutions in Japan; in 2006 there were 16,371 units in 15,020 institutions. (2) In 2006, of the types of institutions with bone densitometry equipment, the number of clinics was the highest, followed in order by general hospitals, other types of institutions, screening institutions and university hospitals. Rates of increase in the installation of equipment in clinics and other types of institutions were high during the 11-year period from 1996. (3) From 1996 to 2006 the region of interest most frequently used for bone densitometry was the radius. However, during the 11-year period, the proportion of radial densitometry equipment in all institutions with bone densitometry equipment decreased, whereas the proportion of calcaneal densitometry equipment increased. (4) The number of dual-energy X-ray absorptiometry (DXA) units was the highest from 1996 to 2006. However, the proportion of DXA machines in all institutions with bone densitometry equipment decreased over the 11-year period, whereas the proportion of quantitative ultrasound (QUS) machines increased. (5) In 2006, bone densitometry equipment was available in 118 institutions per million Japanese people. Central DXA (spine/hip) equipment was available in 15 per million, radial DXA equipment in 63 per million, and calcaneal QUS equipment in 44 per million. (6) In 2006, among those places with bone densitometry equipment, 46% of university hospitals, 14% of general hospitals, 12% of screening institutions, 5% of clinics, and 6% of other types of institutions possessed more

  1. Quantitative determination of alpha-tocopherol in Arbutus unedo by TLC-densitometry and colorimetry.

    Science.gov (United States)

    Kivçak, B; Mert, T

    2001-08-01

    A quantitative determination of alpha-tocopherol in Arbutus unedo leaves was established by TLC-densitometry and colorimetry. Data obtained by TLC-densitometry were compared with those obtained by colorimetry. Also, the alpha-tocopherol content in leaves collected at different times of the year was studied comparatively. The highest amount of alpha-tocopherol was found in the March collection.

  2. Bone densitometry in the Feminine Climacteric routine study or election?

    International Nuclear Information System (INIS)

    Miranda, C.; Estrella, A.; Bozzolo, A.; Sasson, A.; Berterreche, A.

    2002-01-01

    A descriptive and cross-sectional study was conducted, on the basis of a systematic review of the clinical histories of the database, between July 1999 and July 2001.Strategy consisted of reviewing at random clinical data up to obtaining a sample of 100 patients with bone densitometry by mains of dual energy X ray absorbtiometry (DEXA) device. The standard number was statistically significant and representative of the population under study.Results: It is emphasized that more of a hal of the patients studied presented loss of the bone mineral density and 11% with and altered morphometry of the column, similar to other national and international studies. the risk factors for osteoporosis were presented in 71% of the cases, having those patients older densitometric alterations.Conclusions:considering the results and the situation that generates risk of fracture with its high socioeconomic costs, the authors recommend the routine use of the densitometry in the Feminine Climateric or in its absence, a selective screening, reserving the study for patients with given risk factors.It is proposed a guideline to select patients in which conducting the study ia a priority

  3. Mobile bone densitometry service in rural South Australia

    International Nuclear Information System (INIS)

    Tucker, K.N.; Schultz, C.G.; Chatterton, B.E.

    1997-01-01

    Full text: Twenty per cent of South Australia's population live rurally, with limited access to modern medical services. The Mobile Bone Densitometry Unit was established to address this problem. The Unit began in 1994 with cooperation from private industry. In fostering the service, many issues were addressed, including choice of appropriate sites; selection of a liaison person at each site; towing of the Unit; transportation and accommodation of staff; education of local health professionals and community members; promotion of the service to the community: and timely reporting of results to referring doctors. The scanner is an Hologic ODR-1000+ densitometer, housed in a 5.9 1.8 metre, 2200 kg caravan. It is necessary to reduce vibration and motion during travel, control the internal environment, and have an electrically clean power supply. Addressing these parameters result in the critical value for quality control being 2500 patients, averaging 13 patients/working day. The mean age of the patients was 64 y (range 30-90 y), with 93 % of patients being >50 y. Results show a normally distributed Z score, suggesting that non-selected 'normal' population is being studied and the Hologic normal range matches that of the South Australian rural community. Local communities have utilised the service to full capacity resulting in future visits being extended. In conclusion, it is possible to provide a high quality, reliable bone densitometry service to rural communities

  4. Dynamic study of DSA by video-densitometry

    International Nuclear Information System (INIS)

    Imamura, Keiko; Tsukamoto, Hiroshi; Ashida, Hiroshi; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    A system was developed for the dynamic study of DSA by video-densitometric technique. As subtraction images are stored to VTR in our DSA examinations, a frame counter was designed to select images on VTR at an arbitrary interval. ROI setting and video-densitometry were performed using a TV image processor and its host computer. Images were sampled at the rate of 3 frames per second, and clear time-density curves were obtained from brain DSA examinations. Although it takes about 30 minutes to analyse one examination, it is also possible to analyse previous data stored on VTR. For DSA systems having no additional digital storage unit, this method will be helpful. Reduction in image quality through VTR storage had no problem in video-densitometry. Phantom studies have been made concerning the temporal variation of the image brightness during the 20 second-exposure and also the effect of the subjects thickness on the contrast. Filtering for low-grade averaging is preferable for dynamic studies. (author)

  5. Evaluation of surviving fraction using nonclonogenic staining densitometry method

    International Nuclear Information System (INIS)

    Nishiguchi, Iku; Ogawa, Koichi; Ito, Hisao; Hashimoto, Shozo

    1994-01-01

    This study was performed to compare our nonclonogenic survival assay (densitometry assay, DM assay) with the widely used clonogenic assay. The established cell lines (HaLa, RMUG, IMR, GOTO) were grown in F 10 medium. The cells were spread in 24-well plates, irradiated with different doses, cultured for about one week and stained with crystal violet after the culture period. Taking the transparent images of the stained well on the light source with the CCD camera, the images were collected with the matrix size 64 x 64, and the integrated optical density of the entire surface of each well was determined by computer with our original program. As the number of cells in the well is reflected by its staining density, the surviving fraction was calculated as the fraction of growth in the irradiated wells relative to controls. The survival curves obtained by the densitometry method showed good correlations with those obtained by clonogenic assay. It is possible to predict intrinsic radiosensitivity with this assay, even if the cells do not form good colonies. However, this method is based on measurements in cultures which depend on the metabolism and growth kinetics of the irradiated cells. Cells should grow exponetially in the same manner in any well to obtain a result similar to that of clonogenic assay, although growth kinetics may be altered by irradiation. This, the endpoint must be strictly standardized. (author)

  6. Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery

    Directory of Open Access Journals (Sweden)

    Txomin Alberdi

    2018-04-01

    Full Text Available AIM: To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo: anterior capsule (AC, and posterior capsule (PC area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS: This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO and PC opacification (PCO density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS: Using Pearson correlation coefficient (PCC, we found no correlation (r=-0.091, P=0.46 in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43 between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION: Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the

  7. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  8. Patient Doses and Risk Evaluation in Bone Mineral Densitometry

    International Nuclear Information System (INIS)

    Angelucci, M.; Borio, R.; Chiocchini, S.; Degli Esposti, P.; Dipilato, A.C.; Policani, G.

    1999-01-01

    The aim of this work was to evaluate the equipment dose to the organs and tissues and the effective dose of patients undergoing the most frequent examinations carried out in bone mineral densitometry (BMD): lumbar spine and femur. Experimental measurements of absorbed doses on a Rando phantom, allow comparison of the performances of three different photon emitter facilities. The comparison of the entrance and exit doses measured on a Rando phantom and on 50 female non-obese patients show that entrance doses on Rando can be used as 'diagnostic reference levels' for patients. A quantitative estimate of the stochastic risk due to BMD procedures was made: the results obtained show that the stochastic risk is very low and that the BMD is, at present, the most confirmed procedure for osteoporosis diagnosis and management. (author)

  9. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  10. Modifying a Rodenstock scanning laser ophthalmoscope for imaging densitometry.

    Science.gov (United States)

    Tornow, R P; Beuel, S; Zrenner, E

    1997-08-01

    The necessary modifications and technical requirements are described for using a commercially available scanning laser ophthalmoscope (Rodenstock Model 101 SLO) as an imaging densitometer to assess human photopigment distribution. The main requirements are a linear detector amplifier, fast shutters for the laser beams, and a trigger unit. Images must be compensated for varying laser intensity. Both rod and cone photopigments are measured with the 514-nm argon laser of the SLO. Discrimination is possible owing to the different spatial distribution. The cone pigment density peaks in the foveal center (D = 0.40) with a steep decrease with increasing eccentricity E (full width at half-maximum, 2.5 degrees ). Rod photopigment increases with increasing eccentricity (D = 0.23 for E = 11 degrees ). These values are in agreement with previous reported results obtained with scanning laser ophthalmoscopes specially designed for retinal densitometry and high stability.

  11. The analysis of hydrocarbons by dual-energy gamma-ray densitometry

    International Nuclear Information System (INIS)

    Taylor, T.; Reynolds, P.W.; Lipsett, J.J.

    1985-11-01

    Various hydrocarbons have been analyzed noninvasively by dual-energy gamma-ray densitometry. The hydrogen/carbon atomic ratio was deduced for pure hydrocarbons while for heavy oil process samples, the ash content was inferred

  12. Radiation densitometry in tree-ring analysis: a review and procedure manual

    Energy Technology Data Exchange (ETDEWEB)

    Parker, M.L.; Taylor, F.G.; Doyle, T.W.; Foster, B.E.; Cooper, C.; West, D.C.

    1985-01-01

    An x-ray densitometry of wood facility is being established by the Environmental Sciences Division, Oak Ridge Natioanl Laboratory (ORNL). The objective is to apply tree-ring data to determine whether or not there is a fertilizer effect on tree growth from increased atmospheric carbon dioxide since the beginning of the industrial era. Intra-ring width and density data, including ring-mass will be detemined from tree-ring samples collected from sites located throughout the United States and Canada. This report is designed as a guide to assist ORNL scientists in building the x-ray densitometry system. The history and development of x-ray densitometry in tree-ring research is examined and x-ray densitometry is compared with other techniques. Relative wood and tree characteristics are described as are environmental and genetic factors affecting tree growth responses. Methods in x-ray densitometry are examined in detail and the techniques used at four operating laboratories are described. Some ways that dendrochronology has been applied in dating, in wood quality, and environmental studies are presented, and a number of tree-ring studies in Canada are described. An annotated bibliography of radiation densitometry in tree-ring analysis and related subjects is included.

  13. Radiation densitometry in tree-ring analysis: a review and procedure manual

    International Nuclear Information System (INIS)

    Parker, M.L.; Taylor, F.G.; Doyle, T.W.; Foster, B.E.; Cooper, C.; West, D.C.

    1985-01-01

    An x-ray densitometry of wood facility is being established by the Environmental Sciences Division, Oak Ridge Natioanl Laboratory (ORNL). The objective is to apply tree-ring data to determine whether or not there is a fertilizer effect on tree growth from increased atmospheric carbon dioxide since the beginning of the industrial era. Intra-ring width and density data, including ring-mass will be detemined from tree-ring samples collected from sites located throughout the United States and Canada. This report is designed as a guide to assist ORNL scientists in building the x-ray densitometry system. The history and development of x-ray densitometry in tree-ring research is examined and x-ray densitometry is compared with other techniques. Relative wood and tree characteristics are described as are environmental and genetic factors affecting tree growth responses. Methods in x-ray densitometry are examined in detail and the techniques used at four operating laboratories are described. Some ways that dendrochronology has been applied in dating, in wood quality, and environmental studies are presented, and a number of tree-ring studies in Canada are described. An annotated bibliography of radiation densitometry in tree-ring analysis and related subjects is included

  14. Clinical Conformity Between Heel Ultrasound and Densitometry in Postmenopausal Women: A Systematic Review.

    Science.gov (United States)

    Tabor, Elżbieta; Pluskiewicz, Wojciech; Tabor, Kamil

    2018-02-01

    To assess the conformity between heel ultrasound and densitometry, and the clinical application of densitometry T-score "gold standard" in quantitative ultrasound as a method of osteoporosis diagnosis in postmenopausal women. The study is a systematic review of studies published in the last 17 years in PubMed, NLM Gateway, Medline, Embase, and Cochrane Library. Calcaneal quantitative ultrasound sensitivity and specificity were analyzed with regard to densitometry measurements in postmenopausal women. In addition, we summarized the values of ultrasound T-scores, for which their accuracy in osteoporosis diagnosis is the highest. The inclusion criteria met 15 research studies conducted on postmenopausal women. In 11 of them, the authors concluded that clinical conformity between heel ultrasound and densitometry is good. The recommended quantitative ultrasound T-score for osteoporosis diagnosis ranged between -1 and -3.65. Heel ultrasound should be considered to be as accurate as densitometry in diagnosing osteoporosis. Nevertheless, it needs to have separate T-score ranges determined, because those used in densitometry are not adequate. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Generalized Multi-Edge Analysis for K-Edge Densitometry

    International Nuclear Information System (INIS)

    Collins, M.

    1998-01-01

    In K-edge densitometry (KED), a continuous-energy x-ray beam is transmitted through a liquid sample. The actinide content of the sample can be measured through analysis of the transmitted portion of the x-ray beam. Traditional methods for KED analysis allow the simultaneous calculation of, at most, two actinide concentrations. A generalized multi-edge KED analytical method is presented, allowing up to six actinide concentrations to be calculated simultaneously. Applications of this method for hybrid KED/x-ray fluorescence (HKED) systems are discussed. Current HKED systems require the operator to know the approximate actinide content of each sample, and manually select the proper analysis mode. The new multi-edge KED technique allows rapid identification of the major actinide components in a sample, independent of actinide content. The proper HKED analysis mode can be selected automatically, without requiring sample content information from the user. Automatic HKED analysis would be especially useful in an analytical laboratory setting, where samples with truly unknown characteristics are encountered. Because this technique requires no hardware modifications, several facilities that use HKED may eventually benefit from this approach

  16. Quantitative evaluation of catheter radiopacity by fiber optic scanning densitometry

    International Nuclear Information System (INIS)

    Solomon, D.D.; Byron, M.P.; Lipton, M.J.

    1989-01-01

    A rapid accurate method has been developed utilizing fiber optic scanning densitometry to quantify the radiopacity of vascular catheters. The technique provides for computerized calculation of relative catheter radiopacity and an appropriate control standard. A densitometer with a 180 degree collection angle for diffuse transmission density measurements was selected based on the diffusing nature of X-ray film (Q-factor 1.80). A benchmark catheter and 2 mil thick brass shim stock were selected as control standards for evaluation of mono-and multilumen tubing using standard X-ray conditions and an aluminum block attenuator. The authors present results from reproducibility studies which show scan-to-scan repeatability is within ±1%, and day-to-day variability is less than 5%. Application studies demonstrate a linear relationship between percent barium sulfate loading and the radiopaqueness of 16 gauge monolumen tubing. Results were also obtained from a clinical chest X-ray film showing good in-vivo/in-vitro correlation

  17. National protocol for quality assurance in DXA-bone densitometry

    Science.gov (United States)

    Slavchev, A.; Avramova-Cholakova, S.; Vassileva, J.

    2008-01-01

    Osteoporosis becomes largely one of the most important socially significant and costly diseases. Modern techniques (DXA, US) are applied for bone densitometry. The paper presents a protocol for quality assurance especially of DXA-bone densitometers including quality control made in compliance with international standards (ISCD, IOF). The methodology has been tested in practice by measurements on site-functional assessment, entrance dose, radiation protection, calibration, in-vitro precision. It is expected to raise the quality of the diagnostic process in concert with the EU Medical Directive 97/43 particularly for population screening and sensitive groups. The protocol is an essential part of the National Program for constraining osteoporosis which has been elaborated at the Ministry of Health and at present under implementation throughout the country. It aims at reducing the risk, factors spreading, at diminishing the fracture risk the morbidity and the mortality from osteoporosis. An integral multidisciplinary approach to the problem solving is applied as well as training on three levels — doctors, patients, population, which effectively will contribute for obtaining real results in preventing osteoporosis.

  18. Evaluation of a compact portable DEXA unit for wrist densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Mares, T.; Bonovas, G.; Larcos, G. [Westmead Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: Recently, a number of manufacturers have introduced compact, portable DEXA units in order to facilitate osteoporosis screening in remote communities and on an in-office basis. The purposes of this study were to evaluate the accuracy and reproducibility of the Norland-Stratec (pDEXA) compared to measurements obtained using a conventional densitometer (Norland XR-36). We recruited 61 adults (3 men, 58 women) with mean age 54 years (range: 19-76) referred for clinical assessment of BMD. Most patients had medications (n=39; 64%) or disorders (n=48;79%) known to interfere with bone mineral metabolism. Subjects underwent bone densitometry of the lumbar spine, (AP; L2-4) femoral neck and distal radius/ulna of the nondominant forearm using the Norland XR-36, with the wrist subsequently re-scanned on pDEXA. Four subjects also underwent 5 scans each on the pDEXA. Mean BMD for the distal radius/ulna was 0.30g/cm2 (range: 0.17 - 0.539/cm2; XR-36) vs 0.319/cm2 (range: 0.18-0.56 g/cm2; pDEXA), r = 0.98 (SEE = 0.07). Mean BMC for the distal radius/ulna was 1.229 (range: 0.67-2.59; XR-36) vs 1.289 (range:0.74-2.69; pDEXA), r = 0.97 (SEE= 0.08). The CV for pDEXA was 0.8% (BMD) and 2.5% (BMC). Thus, we conclude that pDEXA has excellent in-vivo reproducibility, with good correlation of BMD and BMC with standard densitometers

  19. GEANT4 simulation study of a gamma-ray detector for neutron resonance densitometry

    International Nuclear Information System (INIS)

    Tsuchiya, Harufumi; Harada, Hideo; Koizumi, Mitsuo; Kitatani, Fumito; Takamine, Jun; Kureta, Masatoshi; Iimura, Hideki

    2013-01-01

    A design study of a gamma-ray detector for neutron resonance densitometry was made with GEANT4. The neutron resonance densitometry, combining neutron resonance transmission analysis and neutron resonance capture analysis, is a non-destructive technique to measure amounts of nuclear materials in melted fuels of the Fukushima Daiichi nuclear power plants. In order to effectively quantify impurities in the melted fuels via prompt gamma-ray measurements, a gamma-ray detector for the neutron resonance densitometry consists of cylindrical and well type LaBr 3 scintillators. The present simulation showed that the proposed gamma-ray detector suffices to clearly detect the gamma rays emitted by 10 B(n, αγ) reaction in a high environmental background due to 137 Cs radioactivity with its Compton edge suppressed at a considerably small level. (author)

  20. The value of scintimetry compared with histomorphology, parathormone assay, densitometry and radiology in renal osteopathy

    International Nuclear Information System (INIS)

    Lingg, G.; Nebel, G.; Dorr, S.; Allgemeines Krankenhaus Barmbek, Hamburg

    1982-01-01

    The value of scintimetry compared with histomorphology, parathormone assay, densitometry and radiology in renal osteopathy. The distribution of sup(99m)Tc-Sn-MDP in the thigh was estimated according to two different indices 60 normal patients, 21 patients undergoing haemodialysis and one who had had a renal transplant. Deviation of the indices in these patients from the normal are significant. The indices were correlated with respect to their accuracy in detecting renal osteopathy with histomorphometry (as the reference method), radiological diagnosis, densitometry, parathormone assay and other laboratory tests. Accuracy of the method is high and, like histomorphometry, is over 9O%. (orig.) [de

  1. Value of scintimetry compared with histomorphology, parathormone assay, densitometry and radiology in renal osteopathy

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Nebel, G.; Dorr, S.

    1982-01-01

    The value of scintimetry is compared with histomorphology, parathormone assay, densitometry and radiology in renal osteopathy. The distribution of sup(99m)Tc-Sn-MDP in the thigh was estimated according to two different indices in 60 normal patients, 21 patients undergoing haemodialysis and one who had had a renal transplant. Deviation of the indices in these patients from the normal are significant. The indices were correlated with respect to their accuracy in detecting renal osteopathy with histomorphometry (as the reference method), radiological diagnosis, densitometry, parathormone assay and other laboratory tests. Accuracy of the method is high and, like histomorphometry, is over 9O%.

  2. Determination of bone density via /sup 125/I-densitometry in idiophathic scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Matzen, K.A.; Milachowski, K.A.; Weinberger, N.; Rohloff, R.

    1984-12-01

    The aim of the present study was to find out whether idiopathic scoliosis is associated with a general reduction of the calcium salt content of the bones. The study was conducted in a scoliosis patient group of 48 individuals, using /sup 125/I densitometry.

  3. Area densitometry using rotating Scheimpflug photography for posterior capsule opacification and surface light scattering analyses.

    Science.gov (United States)

    Minami, Keiichiro; Honbo, Masato; Mori, Yosai; Kataoka, Yasushi; Miyata, Kazunori

    2015-11-01

    To compare area densitometry analysis using rotating Scheimpflug photography in quantifications of posterior capsule opacification (PCO) and surface light scattering with previous anterior-segment analyzer measurement. Miyata Eye Hospital, Miyazaki, Japan. Prospective observational case series. Scheimpflug images of eyes with foldable intraocular lenses (IOLs) were obtained using rotating and fixed Scheimpflug photography. Area densitometry on the posterior and anterior surfaces was conducted for PCO and surface light scattering analyses, respectively, with an identical area size. Correlation between two measurements was analyzed using linear regression. The study included 105 eyes of 74 patients who received IOLs 1 to 18 years (mean, 4.9 ± 4.5 years) postoperatively. In the PCO analysis on the posterior IOL surface, there was a significant correlation between the two measurements (P photography exhibited saturation due to intensive scatterings. Area densitometry combined with a rotating Scheimpflug photography was exchangeable to previously established densitometry measurement, and allowed successive evaluation in longer-term observations. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Application of X-ray K-edge densitometry in D and D operations

    International Nuclear Information System (INIS)

    Jensen, T.; Aljundi, T.; Gray, J.N.; Iowa State Univ., Ames, IA

    1998-01-01

    K-edge densitometry is a nondestructive assay technique which provides accurate measurement of heavy metal contamination in pipes, containers, and other items encountered in D and D operations. A prototype mobile K-edge instrument has been built and demonstrated in several applications. Results from measurements of uranium in pipes and spent reactor fuel plates, and quantification of mercury and lead in waste drums are presented. In this report the authors briefly describe the theory behind K-edge densitometry. They follow that with a description of the prototype system they have developed, and a presentation of results from demonstrations of this system. They conclude with a discussion of the potential for application of K-edge analysis in D and D operations

  5. Application of gamma-ray densitometry in developing primary upgrading processes

    International Nuclear Information System (INIS)

    Liu, D.D.S.; Patmore, D.J.

    1990-01-01

    Gamma-ray densitometry has been applied in developing processes for upgrading heavy oils, refinery residua, tar sand bitumen and coal into synthetic crudes. These processes normally operate at high temperatures and pressures, thus non-invasive monitors are highly desirable. Examples of applications at CANMET are given for the following three areas: gas-liquid and gas-liquid-solid multiphase flow hydrodynamic studies, monitoring of ash concentration and measurement of thermal expansion coefficient of liquids. (author)

  6. Reconciling competing priorities in commissioning: the future of bone densitometry service for North Wales

    Directory of Open Access Journals (Sweden)

    Russell Ian

    2007-01-01

    Full Text Available Abstract Background Osteoporosis creates brittle bones susceptible to fracture, with resulting high levels of morbidity and mortality. Poor access to bone densitometry services for the residents of North Wales led to the Welsh Assembly Government offering capital to purchase a dual-energy X-ray absorptiometry (DXA scanner, used to diagnose osteoporosis, for the region. The commissioning question for the six Local Health Boards across North Wales was where to site the new scanner. This decision needed to reflect current inequalities in access to services and concerns over inappropriate prescribing relative to Welsh norms. Methods Epidemiological, corporate and comparative healthcare needs assessments were performed. In addition, two cross-sectional surveys were conducted to determine the views of general practices and users of bone densitometry services resident in North Wales. An option appraisal and sensitivity analysis of 13 costed options for DXA scanning was conducted. Results We estimated that only 31% of the people in North Wales who met national guidelines were receiving DXA scans. There was definite inequity of access to the current service provided by area of residence. There was also evidence of inequity of access by age and sex. The most suitable option identified in the option appraisal was a bone densitometry service based in the central location of Llandudno. Conclusion The assessment identified significant unmet need for DXA scanning. A recommendation was made to improve access through the introduction of a new bone densitometry service based at Llandudno. This would double scanning provision provided and reduce travel costs and time for many North Wales residents. This recommendation was adopted by a joint commissioning group established by the six Local Health Boards in North Wales at the end of 2004 – evidence based commissioning in practice.

  7. An evaluation on the accuracy of the indirect digital images densitometry by modified Photoshop software

    Directory of Open Access Journals (Sweden)

    Bashizadeh Fakhar H.

    2004-06-01

    Full Text Available Statement of Problem: One of the major goals, in most dental researches, is to measure bone destruction or deposition due to the progression or regression of disease. Failure of human eyes to detect minor radiographic density changes resulted in more accurate methods such as optical densitometry and direct or indirect digital densitometry."nPurpose: The aim of this study was to determine the accuracy of a newly proposed method of indirect digital densitometry using modified Photoshop software."nMaterials and Methods: Radiographs from 37 samples of urografin solution with three concentrations (12.5%, 25% and 37.5% were taken on dental radiographic films no.2 and digitized by a scanner. A region with 800*800 pixels was cropped from each image and compressed with the Joint Photographic Experts Group (JPEG compression algorithm and saved. These new images were then put into registration with new algorithm using MATLAB software version 6.1. This algorithm assigned each image and average pixel value (between 0 and 255. The association between concentration and calculated values for each image was tested with regression analysis and the meaning fullness of differences between calculated values was also analysis by ANOVA test. Tukey HSD and Alpha Krunbach were used whenever needs."nResults: Regression analysis revealed significant correlation between concentration and calculated average pixel value (r=0.883. The differences between average of pixels value for different concentration was significant (P=0.0001. Pixel values showed a good intra- sample and intra-group repeatability (Alpha Krunbach: a=99.96%, a=99.68%."nConclusion: This method due to its high accuracy, easy usage and densitometer independency can be considered as a suitable alternative for conventional densitometry methods.

  8. Radiodense concretions in maxillary sinus aspergillosis: pathogenesis and the role of CT densitometry

    International Nuclear Information System (INIS)

    Lenglinger, F.X.; Krennmair, G.; Mueller-Schelken, H.; Artmann, W.

    1996-01-01

    The purpose of this study was to investigate by CT the origin of radiodense maxillary sinus concretions and whether CT densitometry is effective in the prediction of maxillary sinus aspergillosis and in the differentiation of the origin of these concretions. In a prospective study in 21 patients with radiodense maxillary sinus concretions detected by radiography, a preoperative CT study of the paranasal sinuses and the concretions was undertaken. Additional scans of the upper alveolar ridge were also performed. Radiological findings were compared with clinical symptoms and with CT findings, especially CT densitometry of the sinus concretions and dental root-filling material. All patients underwent a functional Caldwell-Luc operation; histological and microbiological examinations were performed. Fifteen of the 21 patients (71.4%) with radiodense concretions had a histological and microbiological diagnosis of sinus aspergillosis. The sinus concretions had CT densities higher than 2000 HU (Housfield units) in 15 patients and lower than 2000 HU in 6. Fourteen of 15 patients (93.3%) with concretions ahving CT densities higher than 2000 HU had a postoperative diagnosis of maxillary sinus aspergillosis. The mean CT density of the sinus concretions in patients with maxillary sinus aspergillosis was 2868 HU (range 1870-3070 HU), and in patients without aspergiollosis was 778 HU (range 228-2644 HU). The mean CT density of the dental root-filling material was 2866 HU (range 2156-3070 HU). Paranasal sinus CT with CT densitometry of a sinus concretion has a higher accuracy than standard radiogrpahy and clinical findings in the prediction of maxillary sinus aspergillosis (93.3% vs 71.4%). CT densitometry helps to confirm the dental origin of maxillary sinus concretions and to explain a possible dental pathogenesis of maxillary sinus aspergillosis. (orig.)

  9. Wood density variation in Gmelina arborea trees using X-ray densitometry

    International Nuclear Information System (INIS)

    Roque, Roger Moya; Tomazello, Mario

    2005-01-01

    The wood density constitutes the main wood quality parameter by its relationship with anatomical, physical and chemical properties and wood utilization. The modern and accurate methods - like X-ray densitometry - are applied to determine the density spatial distribution in wood sections and pith-bark direction. On the other hand, emphasis to wood utilization from fast growing plantations, like Gmelina arborea in Costa Rica, has been done. The objectives of this study were to determinate the influence of 2 climatic conditions of Costa Rica on radial wood density variation of gmelina trees form fast growing plantations using the X-ray densitometry method. Wood samples were cut at DBH of gmelina trees and transversal thin laths were selected at north-south direction and conditioned at 12% moisture content equilibrium and X-rayed. The radiographic films were revealed and scanned a 256 gray scale with 1000 dpi resolution and the intra tree-ring density were determined by CRAD and CERD software. The results demonstrated that the climatic and forest management affects the wood density variability and the distinctness of tree-ring boundaries of gmelina trees, as well as, the applicability of X-ray densitometry in wood quality analysis. (author)

  10. Optic densitometry in radiographic images to evaluate nutritional secondary hyperparathyroidism in kittens

    International Nuclear Information System (INIS)

    Rahal, S.C.; Mortari, A.C.; Caporali, E.H.G.; Vulcano, L.C.; Santos, F.A.M. dos; Takahira, R.K.; Crocci, A.J.

    2002-01-01

    The aim of this study was to evaluate the modification of bone mineral density, as well as the serum biochemistry variation in the nutritional secondary hyperparathyroidism. Ten crossbreed cats, initial aging between 2 and 3 months, and weighing 820 grams were used. After 10 days of adaptation, they were fed with raw beef heart for 60 days. At the end of adaptation time and every 15 days, exams were realized. The method of optical densitometry in radiographic images of the right radius and ulna was used. There was no statistical difference in the bone mineral densitometry between the end of adaptation period and with 15 days of consuming a diet of beef heart. At 30 days the bone density decreased statistically, and it was in the same level at 45 and 60 days. There was no statistical difference in the serum calcium and phosphorus concentrations in all observation time. Serum alkaline phosphatase concentration varied and it was increased above normal variation in the 45 th and 60 th day of the diet. It was possible to conclude that bone densitometry in radiographic images is an efficient method to evaluate bone demineralization, and calcium, phosphorus and alkaline phosphatase serum biochemistry analysis are limited value [pt

  11. QUANTITATIVE ULTRASOUND BONE DENSITOMETRY IN CHILDREN WITH THALASSAEMIA IN NORTH EAST INDIA

    Directory of Open Access Journals (Sweden)

    Chao Rochek Buragohain

    2016-11-01

    Full Text Available BACKGROUND Thalassaemic children who are on regular blood transfusion are at increased risk of hypothyroidism, growth hormone deficiency, hypoparathyroidism, diabetes mellitus and osteoporosis because of deposition of iron in various endocrine glands with age. Low bone mineral density is a significant problem in these children, which may lead to increased risk for fractures and suboptimal peak bone mass. The aim of the study is to determine the bone health status of children with thalassaemia using quantitative ultrasound densitometry. MATERIALS AND METHODS A case control study was done at Department of Paediatrics, Jorhat Medical College and Hospital, which included 32 regularly transfused thalassaemic children. Age and sex matched healthy controls were included. Quantitative ultrasound bone densitometry was done in both the groups and compared with each other. RESULTS Broadband Ultrasound Attenuation (BUA and Speed of Sound (SOS measurements were found to be independent of sex. BUA values in boys showed increasing trend with age, which was not observed in girls. SOS values did not show any increasing trend with age in both sexes. In both the groups, the BUA and SOS increased continuously with increasing age. The values of BUA were more in control group compared to case group while opposite was noticed with SOS values. BUA values were more when ferritin level was >2000 ng/dL and increased number of blood transfusion, whereas SOS values decreased with increase in serum ferritin level and number of transfusion, which was statistically significant (P=0.0125. Both BUA and SOS values decreased with increased severity of malnutrition, which was statistically significant for SOS (P=0.0266. CONCLUSION Quantitative ultrasound bone densitometry can be used as a screening method to assess the bone health status in children, particularly those with thalassaemia, but requires further studies in large groups.

  12. Comparison of instruments for dual-energy X-ray bone mineral densitometry

    International Nuclear Information System (INIS)

    Vainio, P.; Koski, E.; Ahonen, E.; Leinonen, K.; Sievaenen, H.

    1992-01-01

    While bone mineral densitometry has become a common laboratory test, it is important to pay attention to the compatability of the results from different instruments. In this study results from three commercially available bone densitometers are compared using both patient and phantom studies. Overall correlation between instruments was good but there were systematic discrepancies in the results. The three instruments provided bone mineral density (BMD) values that differed by as much as 13.5% due to differences as large as 6% in bone mineral content and as large as 7% in bone area. Thus, the BMD values obtained from different manufacturers' instruments are not directly comparable. (author)

  13. Accommodating brightness and exposure levels in densitometry of stained polyacrylamide electrophoresis gels

    International Nuclear Information System (INIS)

    Tan, Han Yen; Ng, Tuck Wah; Liew, Oi Wah

    2010-01-01

    Flatbed scanner densitometers can be operated under various illumination and recording exposure levels. In this work, we show that optical density measurement accuracy, sensitivity, and stability of stained polyacrylamide electrophoresis gel densitometry are crucially dependent on these two factors (brightness and exposure level), notwithstanding that the source is monochromatic, spatially uniform, and the measurements are made using an accurately calibrated step wedge in tandem. We further outline a method to accommodate the intensity deviations over a range of illumination and exposure levels in order to maintain sensitivity and repeatability in the computed optical densities. Comparisons were also made with results from a commercial densitometer.

  14. Application of preparations on the basis of a metal complex for the production of a contrast medium for utilization in tomo-densitometry

    International Nuclear Information System (INIS)

    Dietlin, F.; Heitz, F.

    1994-01-01

    The present invention relates to measurements by tomo-densitometry. It relates in particular to compositions usable in tomo-densitometry which are comprised of a solution consisting at least of a salt or a complex of metal of which the atomic weight is comprised between 24 and 66 associated with an appropriate solvent or vehicle

  15. Utilization of bone densitometry for prediction and administration of bisphosphonates to prevent osteoporosis in patients with prostate cancer without bone metastases receiving antiandrogen therapy

    International Nuclear Information System (INIS)

    Holt, Abby; Khan, Muhammad A; Gujja, Swetha; Govindarajan, Rangaswmy

    2014-01-01

    Prostate cancer subjects with prostate-specific antigen (PSA) relapse who are treated with androgen deprivation therapy (ADT) are recommended to have baseline and serial bone densitometry and receive bisphosphonates. The purpose of this community population study was to assess the utilization of bone densitometry and bisphosphonate therapy in men receiving ADT for non-metastatic prostate cancer. A cohort study of men aged 65 years or older with non-metastatic incident diagnoses of prostate cancer was obtained from the Surveillance Epidemiology End Results (SEER)-linked Medicare claims between 2004 and 2008. Claims were used to assess prescribed treatment of ADT, bone densitometry, and bisphosphonates. A total of 30,846 incident prostate cancer cases receiving ADT and aged 65 years or older had no bone metastases; 87.3% (n=26,935) on ADT did not receive either bone densitometry or bisphosphonate therapy. Three percent (n=931) of the cases on ADT received bisphosphonate therapy without ever receiving bone densitometry, 8.8% (n=2,702) of the cases on ADT received bone densitometry without receiving intravenous bisphosphonates, while nearly 1% (0.90%, n=278) of the cases on ADT received both bone densitometry and bisphosphonates. Analysis showed treatment differed by patient characteristics. Contrary to the recommendations, bone densitometry and bisphosphonate therapy are underutilized in men receiving ADT for non-metastatic prostate cancer

  16. The diagnostic value of densitometry in CT differentiation of space-occupying growths in the near of the cranial vault

    International Nuclear Information System (INIS)

    Schmitt, W.G.H.; Voigt, K.

    1983-01-01

    Hardening of the beam is a major disturbing effect in densitometry close to the calotte. This phenomenon is demonstrated in a phantom, and its theoretical base is discussed. If possible sources of error are considered and reduced by means of appropriate measuring conditions, measurement of density will furnish useful additional data in CT examination. The value of CT densitometry is demonstrated via follow-up observations; after an operation of a glioma of the optic nerve, a child developed hygromas complicated by superinfection which subsequently became horny or calcified. (orig.) [de

  17. A Comparison of Radiographic Film Densitometry Using a New Computerized Tool with a Digital Densitometer

    Directory of Open Access Journals (Sweden)

    Hoorieh Bashizadeh Fakhar

    2016-11-01

    Full Text Available Objectives: The purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge.Materials and Methods: We reviewed 50 Kodak E-speed intraoral films. An aluminum step wedge consisting of 16 steps was constructed. Each step was 1mmx3mx10mm. The step wedge was exposed to varying exposure times, ranging from 0.05 second to 0.5 second, increasing in 0.05 second increments. Films were digitalized after processing and the MATLAB software algorithm was ran subsequently. Density of the films was measured again using a digital densitometer. In order to compare the two imaging techniques, three steps were selected. Output data from the MATLAB algorithm were compared with data obtained from the digital densitometer.Results: The new method could detect significant differences between subsequent exposure times in step 7, while the densitometer did that in steps 7 and 12. The new method’s sensitivity in determining density changes was 5.26%, 84.1% and 93.02% in steps 2, 7, and 12 respectively.Conclusions: Our new method has an acceptable sensitivity for determining density changes of at least 7 mmEq/Al.Keywords: Densitometry; Image Processing, Computer-Assisted; Aluminum; Phantoms, Imaging

  18. Using X-ray, K-edge densitometry in spent fuel characterization

    International Nuclear Information System (INIS)

    Jensen, T.; Aljundi, T.; Gray, J.N.

    1998-01-01

    There are instances where records for spent nuclear fuel are incomplete, as well as cases where fuel assemblies have deteriorated during storage. To bring these materials into compliance for long term storage will require determination of parameters such as enrichment, total fissionable material, and burnup. To obtain accurate estimates of these parameters will require the combination of information from different inspection techniques. A method which can provide an accurate measure of the total uranium in the spent fuel is X-ray K-edge densitometry. To assess the potential for applying this method in spent fuel characterization, the authors have measured the amount of uranium in stacks of reactor fuel plates containing nuclear materials of different enrichments and alloys. They have obtained good agreement with expected uranium concentrations ranging from 60 mg/cm 2 to 3,000 mg/cm 2 , and have demonstrated that these measurements can be made in a high radiation field (> 200 mR/hr)

  19. Analisis pestisida karbaril dengan metode KLT-Densitometri dalam matriks kedelai dan validasi metodenya

    Directory of Open Access Journals (Sweden)

    Sugijanto Erma Sugijanto

    2012-02-01

    Full Text Available A simple and rapid densitometric method has been developed for determination of low levels of carbaryl in soy bean matrix samples.Sample carbaryl in the soybean matrix was extracted with acetonitril, chloroform and NaCl 0.2 % solution, and the resulting chloroformlayer was separated, added sodium sulphate anhydrous to get free of water than evaporated. After dissolution in methanol, the solutionswere spotted on silica gel GF254 plates which were then eluted with toluene: ethyl acetate = 3:1 (v/v. Quantitative evaluation wasperformed by measuring the absorbance reflectance of the analyte spots at λ 280 nm. This densitometric method is selective, precise,accurate and can be used for the determination carbaryl in soy bean matrix.Key words: carbaryl, TLC-densitometry, validation methode, soy bean

  20. Sequential analysis of biochemical markers of bone resorption and bone densitometry in multiple myeloma

    DEFF Research Database (Denmark)

    Abildgaard, Niels; Brixen, K; Eriksen, E.F

    2004-01-01

    BACKGROUND AND OBJECTIVES: Bone lesions often occur in multiple myeloma (MM), but no tests have proven useful in identifying patients with increased risk. Bone marker assays and bone densitometry are non-invasive methods that can be used repeatedly at low cost. This study was performed to evaluate...... 6 weeks, DEXA-scans performed every 3 months, and skeletal radiographs were done every 6 months as well as when indicated. RESULTS: Serum ICTP and urinary NTx were predictive of progressive bone events. Markers of bone formation, bone mineral density assessments, and M component measurements were...... changes, and our data do not support routine use of sequential DEXA-scans. However, lumbar DEXA-scans at diagnosis can identify patients with increased risk of early vertebral collapses. Sequential analyses of serum ICTP and urinary NTx are useful for monitoring bone damage....

  1. Densitometria clínica: posições oficiais 2006 Clinical densitometry: official positions 2006

    Directory of Open Access Journals (Sweden)

    Cristiano A. F. Zerbini

    2007-02-01

    Full Text Available Descrevemos as posições oficiais da Sociedade Brasileira de Densitometria Clínica (SBDens para a realização e o relato do exame de densitometria óssea. Essas posições foram obtidas por consenso em encontro realizado em São Paulo no ano de 2006. A SBDens contou com o apoio de várias sociedades científicas descritas no texto.We describe the official positions of the Brazilian Society for Clinical Densitometry (SBDens for the performance and report of the bone mineral density testing. These positions were obtained by consensus in a meeting at São Paulo in 2006. SBDens positions were supported by other scientific societies described in the text.

  2. Full-field optical thickness profilometry of semitransparent thin films with transmission densitometry

    International Nuclear Information System (INIS)

    Johnson, Jay; Harris, Tequila

    2010-01-01

    A novel bidirectional thickness profilometer based on transmission densitometry was designed to measure the localized thickness of semitransparent films on a dynamic manufacturing line. The densitometer model shows that, for materials with extinction coefficients between 0.3 and 2.9 D/mm, 100-500 μm measurements can be recorded with less than ±5% error at more than 10,000 locations in real time. As a demonstration application, the thickness profiles of 75 mmx100 mm regions of polymer electrolyte membrane (PEM) were determined by converting the optical density of the sample to thickness with the Beer-Lambert law. The PEM extinction coefficient was determined to be 1.4 D/mm, with an average thickness error of 4.7%.

  3. Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction

    Directory of Open Access Journals (Sweden)

    Faria-Correia F

    2016-04-01

    Full Text Available Fernando Faria-Correia,1–5 Bernardo T Lopes,5,6 Isaac C Ramos,5,6 Tiago Monteiro,1,2 Nuno Franqueira,1 Renato Ambrósio Jr5–8 1Ophthalmology Department, Hospital de Braga, Braga, Portugal; 2Life and Health Sciences Research Institute (ICVS, School of Health Sciences, University of Minho, Braga, Portugal; 3ICVS/3B’s - PT Government Associate Laboratory, Braga, Portugal; 4ICVS/3B’s - PT Government Associate Laboratory, Guimarães, Portugal; 5Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil; 6Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil; 7VisareRio, Rio de Janeiro, Brazil; 8Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo, Brazil Purpose: To evaluate the correlations between preoperative Scheimpflug-based lens densitometry metrics and phacodynamics. Methods: The Lens Opacities Classification System III (LOCS III was used to grade nuclear opalescence (NO, along with different methods of lens densitometry evaluation (absolute scale from 0% to 100%: three-dimensional (3D, linear, and region of interest (ROI modes. Cumulative dissipated energy (CDE and total ultrasound (US time were recorded and correlated with the different methods of cataract grading. Significant correlations were evaluated using Pearson or Spearman correlation coefficients according to data normality. Results: A positive correlation was detected between the NO score and the average density and the maximum density derived from the 3D mode (r=0.624, P<0.001; r=0.619, P<0.001, respectively and the ROI mode (r=0.600, P<0.001; r=0.642, P<0.001, respectively. Regarding the linear mode, only the average density parameter presented a significant relationship with the NO score (r=0.569, P<0.001. The 3D-derived average density and maximum density were positively correlated with CDE (rho =0.682, P<0.001; rho =0.683, P<0.001, respectively and total US time (rho =0.631 and rho =0

  4. Lung structure and function relation in systemic sclerosis: Application of lung densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Ninaber, Maarten K., E-mail: m.k.ninaber@lumc.nl [Department of Pulmonology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Stolk, Jan; Smit, Jasper; Le Roy, Ernest J. [Department of Pulmonology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Kroft, Lucia J.M. [Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Els Bakker, M. [Division of Image Processing, Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Vries Bouwstra, Jeska K. de; Schouffoer, Anne A. [Department of Rheumatology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands); Staring, Marius; Stoel, Berend C. [Division of Image Processing, Radiology, Leiden University Medical Center, Albinusdreef 2, 2333ZA Leiden (Netherlands)

    2015-05-15

    Highlights: • A quantitative CT parameter of lung parenchyma in systemic sclerosis is presented. • We examine the optimal percentage threshold for the percentile density. • The 85th percentile density threshold correlated significantly with lung function. • A lung structure–function relation is confirmed. • We report applicability of Perc85 in progression mapping of interstitial lung disease. - Abstract: Introduction: Interstitial lung disease occurs frequently in patients with systemic sclerosis (SSc). Quantitative computed tomography (CT) densitometry using the percentile density method may provide a sensitive assessment of lung structure for monitoring parenchymal damage. Therefore, we aimed to evaluate the optimal percentile density score in SSc by quantitative CT densitometry, against pulmonary function. Material and methods: We investigated 41 SSc patients by chest CT scan, spirometry and gas transfer tests. Lung volumes and the nth percentile density (between 1 and 99%) of the entire lungs were calculated from CT histograms. The nth percentile density is defined as the threshold value of densities expressed in Hounsfield units. A prerequisite for an optimal percentage was its correlation with baseline DLCO %predicted. Two patients showed distinct changes in lung function 2 years after baseline. We obtained CT scans from these patients and performed progression analysis. Results: Regression analysis for the relation between DLCO %predicted and the nth percentile density was optimal at 85% (Perc85). There was significant agreement between Perc85 and DLCO %predicted (R = −0.49, P = 0.001) and FVC %predicted (R = −0.64, P < 0.001). Two patients showed a marked change in Perc85 over a 2 year period, but the localization of change differed clearly. Conclusions: We identified Perc85 as optimal lung density parameter, which correlated significantly with DLCO and FVC, confirming a lung parenchymal structure–function relation in SSc. This provides

  5. CT Densitometry of the Lung in Healthy Nonsmokers with Normal Pulmonary Function

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tack Sun; Chae, Eun Jin; Seo, Joon Beom; Jung, Young Ju; Oh, Yeon Mok; Lee, Sang Do [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-09-15

    To investigate the upper normal limit of low attenuation area in healthy nonsmokers. A total of 36 nonsmokers with normal pulmonary function test underwent a CT scan. Six thresholds (-980 --930 HU) on inspiration CT and two thresholds (-950 and -910 HU) on expiration CT were used for obtaining low attenuation area. The mean lung density was obtained on both inspiration CT and expiration CT. Descriptive statistics of low attenuation area and the mean lung density, evaluation of difference of low attenuation area and the mean lung density in both sex and age groups, analysis of the relationship between demographic information and CT parameters were performed. Upper normal limit for low attenuation area was 12.96% on inspiration CT (-950 HU) and 9.48% on expiration CT (-910 HU). Upper normal limit for the mean lung density was -837.58 HU on inspiration CT and 686.82 HU on expiration CT. Low attenuation area and the mean lung density showed no significant differences in both sex and age groups. Body mass index (BMI) was negatively correlated with low attenuation area on inspiration CT (-950 HU, r = -0.398, p = 0.016) and positively correlated with the mean lung density on inspiration CT (r 0.539, p = 0.001) and expiration CT (r = 0.432, p = 0.009). Age and body surface area were not correlated with low attenuation area or the mean lung density. Low attenuation area on CT densitometry of the lung could be found in healthy nonsmokers with normal pulmonary function, and showed negative association with BMI. Reference values, such as range and upper normal limit for low attenuation area in healthy subjects could be helpful in quantitative analysis and follow up of early emphysema, using CT densitometry of the lung.

  6. Quantitative applications of gamma densitometry in the coal industry: a critique

    International Nuclear Information System (INIS)

    Shea, P.; Sher, R.; Gozani, T.

    1982-01-01

    This paper discusses the use of gamma densitometry to quantitatively assay bulk samples of coal on a continuous basis. Devices using these principles to determine mass flows are on the market, and work is progressing in several countries on instruments to determine ash content. The theoretical limits of applicability and inherent assumptions of these techniques are discussed, primarily as applied to dry bulk coal, but with some discussion of the more complicated problems of slurried coal. Gamma rays are generated by sources, usually a single radioactive element. These have several advantages over XRF, the main one being that no power is required to generate gammas. However, there are a limited number of gamma sources with useful energies, long enough half-lives to be economically useful, and clean spectra (that is, relatively few energies emitted by the source in question). Gamma densitometry measurements by single and multiple-energy transmission and backscatter measurements are discussed. A general formalism for analyzing multiple-energy systems is presented. While multi-energy systems can, in principle, pick out as many groups of elements as energies used, the matrices involved are ill-conditioned and thus require accurate measures of count rate (i.e., long counting times or high source intensities) to achieve acceptable errors. Changes in coal composition and profile of coal on a belt were also seen to be important sources of error. Transmission measurements are more amenable to analysis than backscatter, which are essentially transmission measurements made on a distributed source. In addition, transmission measurements are not restricted to low energy gamma sources, and can survey the entire bulk of coal rather than just the upper portion. The special problems of slurried coal measurements are briefly discussed

  7. MicroCT Bone Densitometry: Context Sensitivity, Beam Hardening Correction and the Effect of Surrounding Media

    Directory of Open Access Journals (Sweden)

    Philip L. Salmon

    2014-12-01

    Full Text Available The context-sensitivity of microCT bone densitometry due to beam hardening artefacts was assessed. Bones and teeth are scanned with varying thickness of surrounding media (water, alcohol, biological tissue and it is important to understand how this affects reconstructed attenuation (“density” of the mineralized tissue. Aluminium tubes and rods with thickness 0.127mm–5mm were scanned both in air or surrounded by up to 2cm of water. Scans were performed with different energy filters and degrees of software beam hardening correction (BHC. Also tested were the effects of signal-to-noise ratio, magnification and truncation. The thickness of an aluminium tube significantly affected its mean reconstructed attenuation. This effect of thickness could be reduced substantially by BHC for scans in air, but not for scans in water. Varying thickness of surrounding water also changed the mean attenuation of an aluminium tube. This artefact could be almost eliminated by an optimal BHC value. The “cupping” artefact of heterogeneous attenuation (elevated at outer surfaces could be corrected if aluminium was scanned in air, but in water BHC was much less effective. Scan truncation, changes to magnification and signal-to-noise ratio also caused artificial changes to measured attenuation. Measurement of bone mineral density by microCT is highly context sensitive. A surrounding layer of liquid or biological tissue reduces the ability of software BHC to remove bone density artefacts. Sample thickness, truncation, magnification and signal to noise ratio also affect reconstructed attenuation. Thus it is important for densitometry that sample and calibration phantom dimensions and mounting materials are standardised.

  8. Radiotherapy film densitometry using a slow-scan, cooled, digital CCD imaging system

    International Nuclear Information System (INIS)

    Burch, S.E.

    1993-01-01

    A method of performing high-resolution two-dimensional film densitometry for full size radiographic film (35 x 43 cm) using a cooled CCD camera was proposed. Studies were performed to evaluate the physical characteristics of the camera system and recommendations were made to assure maximum accuracy of density measurement. Test films of various sizes and densities, as well as clinical dosimetry films, were measured with the CCD densitometer and the reference transmission densitometer. The measured densities agreed within the stated accuracy of the transmission densitometer for all films with maximum density less than or equal to 1.5 optical density units. The 0.2 mm spatial resolution with 4096 shades of gray made it possible to study dose distributions even for films containing areas of high dose gradients. Patient verification radiographs were used to study exit beam dose distributions to detect errors in beam placement, patient position, and proper placement of beam modifying devices such as wedges and compensators. For studying photon beam dose distributions within phantoms, a method was developed using lead foils placed lateral to the film plane to filter very low energy scattered photons. The error in measurement of central axis percentage depth dose from film for 4 MV x-rays, 25 x 25 cm field was decreased from 65% to 4%. The method requires only two calibration films for density to dose conversion and represents an important advance in the field of film densitometry for radiotherapy. The technique was applied to the study of dynamic wedge dose distribution from a 6 MV linear accelerator. The phantom modification decreased the error in percentage depth dose from 21% to 1% for the 15 x 15 cm beam with 60 degree wedge angle. Profile off-axis errors for the same beam were decreased from 8% to 3%. The film dosimetry system provides fast, high resolution film density data for use in radiotherapy imaging and quality assurance

  9. Detection of somatic mosaicism in DMD using computer-assisted laser densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J.E.; Allingham-Hawkins, D.J.; MacKenzie, J. [Hospital for Sick Children, Toronto (Canada)] [and others

    1994-09-01

    Approximately two-thirds of Duchenne muscular dystrophy (DMD) patients have a deletion in the dystrophin gene located at Xp21.1. Two PCR-based multiplex systems have been developed which detect 98% of deletions in affected males. Diagnosis of carrier females requires densitometry of PCR products following gel electrophoresis to calculate dosage of specific exons. We have developed a system in which fluorescently labelled PCR products are analysed using a GENESCANNER automated fragment analyser (ABI). Dosage is determined using computer-assisted laser densitometry (CALD). Recently, we diagnosed somatic mosaicism in the mother of an affected boy using this method. PCR analysis showed that the patient had a deletion that included exons 47-51 of his dystrophin gene. CALD analysis on the patient`s 36-year-old mother revealed a 29-34% reduction in the intensity of the bands corresponding to the deleted region of the gene rather than the 50% reduction normally seen in carrier females. A skin biopsy was obtain and monoclonal fibroblast colonies were tested by CALD for the deletion. Four of the twenty colonies screened were found to be deleted while the remaining colonies had two intact copies of the gene. We conclude that this patient is a somatic mosaic for DMD and that the mutation was the result of a post-zygotic event. This is the only case of somatic mosaicism detected among 800 women from 400 DMD families tested using CALD in our laboratory. At least one other case of possible somatic mosaicism has been reported but not confirmed. Germinal mosaicism is thought to occur in approximately 10% of mothers of sporadic DMD patients. Our findings indicate that somatic mosaicism is a much rarer condition among DMD carriers, thus suggesting that mitotic mutations in the dystrophin gene are more likely to occur later in embryogenesis after differentiation of the germline.

  10. Lung structure and function relation in systemic sclerosis: Application of lung densitometry

    International Nuclear Information System (INIS)

    Ninaber, Maarten K.; Stolk, Jan; Smit, Jasper; Le Roy, Ernest J.; Kroft, Lucia J.M.; Els Bakker, M.; Vries Bouwstra, Jeska K. de; Schouffoer, Anne A.; Staring, Marius; Stoel, Berend C.

    2015-01-01

    Highlights: • A quantitative CT parameter of lung parenchyma in systemic sclerosis is presented. • We examine the optimal percentage threshold for the percentile density. • The 85th percentile density threshold correlated significantly with lung function. • A lung structure–function relation is confirmed. • We report applicability of Perc85 in progression mapping of interstitial lung disease. - Abstract: Introduction: Interstitial lung disease occurs frequently in patients with systemic sclerosis (SSc). Quantitative computed tomography (CT) densitometry using the percentile density method may provide a sensitive assessment of lung structure for monitoring parenchymal damage. Therefore, we aimed to evaluate the optimal percentile density score in SSc by quantitative CT densitometry, against pulmonary function. Material and methods: We investigated 41 SSc patients by chest CT scan, spirometry and gas transfer tests. Lung volumes and the nth percentile density (between 1 and 99%) of the entire lungs were calculated from CT histograms. The nth percentile density is defined as the threshold value of densities expressed in Hounsfield units. A prerequisite for an optimal percentage was its correlation with baseline DLCO %predicted. Two patients showed distinct changes in lung function 2 years after baseline. We obtained CT scans from these patients and performed progression analysis. Results: Regression analysis for the relation between DLCO %predicted and the nth percentile density was optimal at 85% (Perc85). There was significant agreement between Perc85 and DLCO %predicted (R = −0.49, P = 0.001) and FVC %predicted (R = −0.64, P < 0.001). Two patients showed a marked change in Perc85 over a 2 year period, but the localization of change differed clearly. Conclusions: We identified Perc85 as optimal lung density parameter, which correlated significantly with DLCO and FVC, confirming a lung parenchymal structure–function relation in SSc. This provides

  11. Determination of strain concentration by microfluorescent densitometry of X-ray topography: a bridge between microfracture and continuum mechanics

    International Nuclear Information System (INIS)

    Kalman, Z.H.; Chaudhuri, J.; Weng, G.J.; Weissmann, S.

    1980-01-01

    The strain distribution in the vicinity of the notches of a double-notched, elastically bent silicon crystal was determined by measuring the diffracted X-ray intensities. The measurements were carried out on traverse-oscillation topographs of a crystal section extending through both notches. Strain distributions were determined by measuring the local densities of silver deposits (measurements of 'opacities') with a scanning electron microscope. It was shown that both the density range and spatial resolution of X-ray densitometry were larger by an order of magnitude than those of optical densitometry. The strain concentration factors associated with the notches were measured experimentally and calculated by continuum mechanics. The results were in satisfactory agreement. Also, the experimentally found rise of strains, to a maximum in the critical area adjacent to the notch root, followed the trend predicted by continuum mechanics. (Auth.)

  12. Application of genomic densitometry for calculating the relative population of Escherichia Coli in the intestine of broiler chicks

    Directory of Open Access Journals (Sweden)

    A.R Seidavi

    2009-05-01

    Full Text Available In this study, the densitometry technique for calculating of the relative population of Escherichia coli in various segments of the intestine of broiler chicks was evaluated. Following preparation of the intestinal contents, the process of extraction and purification of DNA from the contents of duodenum, jejunum, ileum and cecum was undertaken. A specific polymerase chain reaction (PCR using two pairs of primers was employed to detect Escherichia coli and total bacteria present in the gastrointestinal tract of the chicks. Specific bands of E.coli were obtained using densitometry and Gel Proc Analyzer software based on linear regression with extrapolation. E.coli populations at different ages were also determined in various segments of the gastrointestinal tract of the chicks. The Results of this experiment indicated that 0.000004%, 0.07%, 0.64% and 2.51% of total bacteria present in the duodenum, jejunum, ileum and cecum respectively consisted of E.coli. Also, E.coli constitutes 1.76, 0.01 and 0.80% of the total intestinal bacteria of chicks at 4, 14 and 30 days of age respectively. Furthermore, it was shown that at 4 days of age, 0.30, 2.05 and 3.97% of the total bacteria present in the jejunum, ileum and cecum respectively were from E.coli species and this bacteria was absent in the duodenum. At 14 days of age these figures were 0.000009%, 0.00011% and 0.08% respectively while at 30 days of age 0.00011%, 0.009% and 2.40% of all bacteria in the duodenum, ileum and cecum were E.coli species and this bacteria was absent in the jejunum. In conclusion, the densitometry method based on PCR results can be regarded as a useful tool for densitometry the relative population E.coli in the gastrointestinal tract of poultry.

  13. Quantitative determination of bone mineral concentrations using quotient densitometry in patients under long-term anticonvulsant therapy

    International Nuclear Information System (INIS)

    Schulz, H.

    1980-01-01

    The effect on bone mineral concentration of anticonvulsive long-term therapy was investigated in order to find out if there is a relation between the occurence and extent of osteomalacial lesions on the one hand and the type and time of application of anticonvulsants. The hydroxyl apatite content was determined by X-ray densitometry. The method is considered to be suitable for yearly skeletal monitoring of epilepticians treated with anticonvulsants. (orig./HP) [de

  14. Scanning laser densitometry and color perimetry demonstrate reduced photopigment density and sensitivity in two patients with retinal degeneration.

    Science.gov (United States)

    Tornow, R P; Stilling, R; Zrenner, E

    1999-10-01

    To test the feasibility of scanning laser densitometry with a modified Rodenstock scanning laser ophthalmoscope (SLO) to measure the rod and cone photopigment distribution in patients with retinal diseases. Scanning laser densitometry was performed using a modified Rodenstock scanning laser ophthalmoscope. The distribution of the photopigments was calculated from dark adapted and bleached images taken with the 514 nm laser of the SLO. This wavelength is absorbed by rod and cone photopigments. Discrimination is possible due to their different spatial distribution. Additionally, to measure retinal sensitivity profiles, dark adapted two color static perimetry with a Tübinger manual perimeter was performed along the horizontal meridian with 1 degree spacing. A patient with retinitis pigmentosa had slightly reduced photopigment density within the central +/- 5 degrees but no detectable photopigment for eccentricities beyond 5 degrees. A patient with cone dystrophy had nearly normal pigment density beyond +/- 5 degrees, but considerably reduced photopigment density within the central +/- 5 degrees. Within the central +/- 5 degrees, the patient with retinitis pigmentosa had normal sensitivity for the red stimulus and reduced sensitivity for the green stimulus. There was no measurable function beyond 7 degrees. The patient with cone dystrophy had normal sensitivity for the green stimulus outside the foveal center and reduced sensitivity for the red stimulus at the foveal center. The results of color perimetry for this patient with a central scotoma were probably influenced by eccentric fixation. Scanning laser densitometry with a modified Rodenstock SLO is a useful method to assess the human photopigment distribution. Densitometry results were confirmed by dark adapted two color static perimetry. Photopigment distribution and retinal sensitivity profiles can be measured with high spatial resolution. This may help to measure exactly the temporal development of retinal

  15. Application of radial basis function in densitometry of stratified regime of liquid-gas two phase flows

    International Nuclear Information System (INIS)

    Roshani, G.H.; Nazemi, E.; Roshani, M.M.

    2017-01-01

    In this paper, a novel method is proposed for predicting the density of liquid phase in stratified regime of liquid-gas two phase flows by utilizing dual modality densitometry technique and artificial neural network (ANN) model of radial basis function (RBF). The detection system includes a 137 Cs radioactive source and two NaI(Tl) detectors for registering transmitted and scattered photons. At the first step, a Monte Carlo simulation model was utilized to obtain the optimum position for the scattering detector in dual modality densitometry configuration. At the next step, an experimental setup was designed based on obtained optimum position for detectors from simulation in order to generate the required data for training and testing the ANN. The results show that the proposed approach could be successfully applied for predicting the density of liquid phase in stratified regime of gas-liquid two phase flows with mean relative error (MRE) of less than 0.701. - Highlights: • Density of liquid phase in stratified regime of two phase flows was predicted. • Combination of dual modality densitometry technique and ANN was utilized. • Detection system includes a 137 Cs radioactive source and two NaI(Tl) detectors. • MCNP simulation was done to obtain the optimum position for the scattering detector. • An experimental setup was designed to generate the required data for training the ANN.

  16. Variation of densitometry on computed tomography in COPD--influence of different software tools.

    Directory of Open Access Journals (Sweden)

    Mark O Wielpütz

    Full Text Available Quantitative multidetector computed tomography (MDCT as a potential biomarker is increasingly used for severity assessment of emphysema in chronic obstructive pulmonary disease (COPD. Aim of this study was to evaluate the user-independent measurement variability between five different fully-automatic densitometry software tools.MDCT and full-body plethysmography incl. forced expiratory volume in 1s and total lung capacity were available for 49 patients with advanced COPD (age = 64±9 years, forced expiratory volume in 1 s = 31±6% predicted. Measurement variation regarding lung volume, emphysema volume, emphysema index, and mean lung density was evaluated for two scientific and three commercially available lung densitometry software tools designed to analyze MDCT from different scanner types.One scientific tool and one commercial tool failed to process most or all datasets, respectively, and were excluded. One scientific and another commercial tool analyzed 49, the remaining commercial tool 30 datasets. Lung volume, emphysema volume, emphysema index and mean lung density were significantly different amongst these three tools (p<0.001. Limits of agreement for lung volume were [-0.195, -0.052 l], [-0.305, -0.131 l], and [-0.123, -0.052 l] with correlation coefficients of r = 1.00 each. Limits of agreement for emphysema index were [-6.2, 2.9%], [-27.0, 16.9%], and [-25.5, 18.8%], with r = 0.79 to 0.98. Correlation of lung volume with total lung capacity was good to excellent (r = 0.77 to 0.91, p<0.001, but segmented lung volume (6.7±1.3-6.8±1.3 l were significantly lower than total lung capacity (7.7±1.7 l, p<0.001.Technical incompatibilities hindered evaluation of two of five tools. The remaining three showed significant measurement variation for emphysema, hampering quantitative MDCT as a biomarker in COPD. Follow-up studies should currently use identical software, and standardization efforts should encompass software as

  17. Pulmonary Emphysema in Cystic Fibrosis Detected by Densitometry on Chest Multidetector Computed Tomography

    Science.gov (United States)

    Wielpütz, Mark O.; Weinheimer, Oliver; Eichinger, Monika; Wiebel, Matthias; Biederer, Jürgen; Kauczor, Hans-Ulrich; Heußel, Claus P.

    2013-01-01

    Background Histopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF. Methods Volumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subjected to dedicated software. The lung was segmented, low attenuation volumes below a threshold of -950 Hounsfield units were assigned to emphysema volume (EV), and the emphysema index was computed (EI). Results were correlated with forced expiratory volume in 1 s percent predicted (FEV1%), residual volume (RV), and RV/total lung capacity (RV/TLC). Results We show that EV was increased in CF (457±530 ml) compared to non-CF controls (78±90 ml) (PEmphysema in CF was detected from early adolescence (~13 years) and increased with age (rs=0.67, Pemphysema detected by densitometry on chest MDCT is a characteristic pathology that contributes to airflow limitation and may serve as a novel endpoint for monitoring lung disease in CF. PMID:23991177

  18. Relationship between metabolic syndrome and its components with bone densitometry in postmenopausal women.

    Science.gov (United States)

    Abbasi, Mahnaz; Farzam, Seyed Amir; Mamaghani, Zahra; Yazdi, Zohreh

    2017-11-01

    Prevention of osteoporosis and bone fracture and the relationship between metabolic syndrome and bone density are controversial issues. The aim of this study was to evaluate the association between metabolic syndrome and its components with bone mineral density in post menopausal women referred for bone mineral density (BMD) test. A total of 143 postmenopausal women with at least one year of menopause experience participated in this cross-sectional study. Demographic and anthropometric characteristics for all participants were collected. Also, biochemical parameters including fasting blood sugar, Cholesterol (HDL and LDL), triglyceride were measured. Association between the components of metabolic syndrome and bone densitometry were analyzed by statistical methods. In this study, 72% of participants did not have metabolic syndrome. Among them, 43.4% and 28.7% had osteoporosis and normal density, respectively. Of remaining participants with metabolic syndrome, 12.6% and 15.4% had osteoporosis and normal density, respectively. Among the metabolic syndrome components, waist circumference, HDL cholesterol, and waist to hip ratio were significantly associated with bone mass (Pmetabolic syndrome did not have significant differences than women without metabolic syndrome in terms of lumbar and femoral neck density (P>0.05). Results from this study showed that metabolic syndrome and its components did not induce bone mass loss. The discrepancies of the studies in this area call for more large scale studies in population so as to prevent women problems in this area. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  19. The study of the precision and accuracy of quality control in DXA bone mineral densitometry

    International Nuclear Information System (INIS)

    Gong Jian; Xu Hao

    2005-01-01

    Objective: To study the precision and accuracy of quality control (QC) in dual-energy X-ray absorptiometry (DXA) bone mineral densitometry so as to raise the reliability and necessity of the results. Methods: 1) Short-term precision trial: 30 people and 30 SD male rats were chosen, and a precision trail was performed. Each people was scanned twice and reposited in next study. The precision and the least significant change (LSC) of each examinated region were calculated. The short-term precision trail of the rats was performed in the similar way. 2) Accuracy trial: measured the body phantom supplied by factor daily, and compared the results with real value, then calculated the accuracy and correction factor. A Shewhart chart was set up based on average values. Results: 1) People's coefficient of variation (CV) and LSC in the lumbar and proximal femur were 0.7%-2.2% and 0.018-0.048 g/cm 2 . Rats' whole body short-term precision was 0.9%. 2) The average accuracy of DXA densitometer was -0.81%, the correction factor was 0.992. The average bone mineral density measured in successive 25 d was 1.244 g/cm 2 , the standard deviation (SD) was 0.008. Conclusion: The precision and accuracy trail can help to get the information about the working state of the instrument and to analyze the measured results, and can effectively raise the reliability of the measure. (authors)

  20. Comparative determination of sibutramine as an adulterant in natural slimming products by HPLC and HPTLC densitometry.

    Science.gov (United States)

    Ariburnu, Etil; Uludag, Mehmet Fazli; Yalcinkaya, Huseyin; Yesilada, Erdem

    2012-05-01

    A new validated method for the identification and quantification of the sibutramine was developed by HPTLC-densitometry at 225 nm and advantages and disadvantages compared with HPLC-FLD at 225 nm emission and 316 nm excitation. Both methods were applied to the analysis of three natural slimming products in the market for the quantitative analysis of illegally added sibutramine. HPTLC separations were performed on (20 cm × 10 cm) glass HPTLC plates coated with silica gel 60 F(254) using a mobile phase, n-hexane-acetone-ammonia (10:1:0.1, v/v/v). For HPLC analysis, a phenyl column (5.0 μm, 150 mm × 4.6 mm, i.d.) and an isocratic mobile phase of acetonitrile-water-formic acid (pH 3.0; 0.19M) (45:55:0.78, v/v/v) was used. The calibration curve area versus concentration was found to be linear in the range of 250-2000 ng/spot(-1) and 5-200 μg/ml for HPTLC and HPLC, respectively. Both methods were validated for accuracy, precision, linearity, selectivity, recovery and short term stability. As a conclusion, these methods were found to be useful for the routine analysis of illegally added sibutramine in the marketed products. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Analysis of multiphase flows using dual-energy gamma densitometry and neural networks

    International Nuclear Information System (INIS)

    Bishop, C.M.; James, G.D.

    1993-01-01

    Dual-energy gamma densitometry offers a powerful technique for the non-intrusive analysis of multiphase flows. By employing multiple beam lines, information on the phase configuration can be obtained. Once the configuration is known, it then becomes possible in principle to determine the phase fractions. In practice, however, the extraction of the phase fractions from the densitometer data is complicated by the wide variety of phase configurations which can arise, and by the considerable difficulties of modelling multiphase flows. In this paper we show that neural network techniques provide a powerful approach to the analysis of data from dual-energy gamma densitometers, allowing both the phase configuration and the phase fractions to be determined with high accuracy, whilst avoiding the uncertainties associated with modelling. The technique is well suited to the determination of oil, water and gas fractions in multiphase oil pipelines. Results from linear and non-linear network models are compared, and a new technique for validating the network output is described. (orig.)

  2. Wood density variation and tree ring distinctness in Gmelina arborea trees by x-ray densitometry

    Directory of Open Access Journals (Sweden)

    Roger Moya

    2009-03-01

    Full Text Available Due to its relationship with other properties, wood density is the main wood quality parameter. Modern, accuratemethods such as X-ray densitometry - are applied to determine the spatial distribution of density in wood sections and to evaluatewood quality. The objectives of this study were to determinate the influence of growing conditions on wood density variation andtree ring demarcation of gmelina trees from fast growing plantations in Costa Rica. The wood density was determined by X-raydensitometry method. Wood samples were cut from gmelina trees and were exposed to low X-rays. The radiographic films weredeveloped and scanned using a 256 gray scale with 1000 dpi resolution and the wood density was determined by CRAD and CERDsoftware. The results showed tree-ring boundaries were distinctly delimited in trees growing in site with rainfall lower than 2510 mm/year. It was demonstrated that tree age, climatic conditions and management of plantation affects wood density and its variability. Thespecific effect of variables on wood density was quantified by for multiple regression method. It was determined that tree yearexplained 25.8% of the total variation of density and 19.9% were caused by climatic condition where the tree growing. Wood densitywas less affected by the intensity of forest management with 5.9% of total variation.

  3. A field-to-desktop toolchain for X-ray CT densitometry enables tree ring analysis.

    Science.gov (United States)

    De Mil, Tom; Vannoppen, Astrid; Beeckman, Hans; Van Acker, Joris; Van den Bulcke, Jan

    2016-06-01

    Disentangling tree growth requires more than ring width data only. Densitometry is considered a valuable proxy, yet laborious wood sample preparation and lack of dedicated software limit the widespread use of density profiling for tree ring analysis. An X-ray computed tomography-based toolchain of tree increment cores is presented, which results in profile data sets suitable for visual exploration as well as density-based pattern matching. Two temperate (Quercus petraea, Fagus sylvatica) and one tropical species (Terminalia superba) were used for density profiling using an X-ray computed tomography facility with custom-made sample holders and dedicated processing software. Density-based pattern matching is developed and able to detect anomalies in ring series that can be corrected via interactive software. A digital workflow allows generation of structure-corrected profiles of large sets of cores in a short time span that provide sufficient intra-annual density information for tree ring analysis. Furthermore, visual exploration of such data sets is of high value. The dated profiles can be used for high-resolution chronologies and also offer opportunities for fast screening of lesser studied tropical tree species. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Compton-scatter tissue densitometry: calculation of single and multiple scatter photon fluences

    International Nuclear Information System (INIS)

    Battista, J.J.; Bronskill, M.J.

    1978-01-01

    The accurate measurement of in vivo electron densities by the Compton-scatter method is limited by attenuations and multiple scattering in the patient. Using analytic and Monte Carlo calculation methods, the Clarke tissue density scanner has been modelled for incident monoenergetic photon energies from 300 to 2000 keV and for mean scattering angles of 30 to 130 degrees. For a single detector focussed to a central position in a uniform water phantom (25 x 25 x 25 cm 3 ) it has been demonstrated that: (1) Multiple scatter contamination is an inherent limitation of the Compton-scatter method of densitometry which can be minimised, but not eliminated, by improving the energy resolution of the scattered radiation detector. (2) The choice of the incident photon energy is a compromise between the permissible radiation dose to the patient and the tolerable level of multiple scatter contamination. For a mean scattering angle of 40 degrees, the intrinsic multiple-single scatter ratio decreases from 64 to 35%, and the radiation dose (per measurement) increases from 1.0 to 4.1 rad, as the incident photon energy increases from 300 to 2000 keV. These doses apply to a sampled volume of approximately 0.3 cm 3 and an electron density precision of 0.5%. (3) The forward scatter densitometer configuration is optimum, minimising both the dose and the multiple scatter contamination. For an incident photon energy of 1250 keV, the intrinsic multiple-single scatter ratio reduces from 122 to 27%, and the dose reduces from 14.3 to 1.2 rad, as the mean scattering angle decreases from 130 to 30 degrees. These calculations have been confirmed by experimental measurements. (author)

  5. Influence of fuel composition on the spent fuel verification by Self‑Interrogation Neutron Resonance Densitometry

    International Nuclear Information System (INIS)

    Rossa, Riccardo; Borella, Alessandro; Van der Meer, Klaas; Labeau, Pierre‑Etienne; Pauly, Nicolas

    2015-01-01

    The Self‑Interrogation Neutron Resonance Densitometry (SINRD) is a passive Non‑Destructive Assay (NDA) that is developed for the safeguards verification of spent nuclear fuel. The main goal of SINRD is the direct quantification of 239Pu by estimating the SINRD signature, which is the ratio between the neutron flux in the fast energy region and in the region close to the 0.3 eV resonance of 239 Pu. The resonance region was chosen because the reduction of the neutron flux within 0.2-0.4 eV is due mainly to neutron absorption from 239 Pu, and therefore the SINRD signature can be correlated to the 239Pu mass in the fuel assembly. This work provides an estimate of the influence of 239 Pu and other nuclides on the SINRD signature. This assessment is performed by Monte Carlo simulations by introducing several nuclides in the fuel material composition and by calculating the SINRD signature for each case. The reference spent fuel library developed by SCK CEN was used for the detailed fuel compositions of PWR 17x17 fuel assemblies with different initial enrichments, burnup, and cooling times. The results from the simulations show that the SINRD signature is mainly correlated to the 239 Pu mass, with significant influence by 235 U. Moreover, the SINRD technique is largely insensitive to the cooling time of the assembly, while it is affected by the burnup and initial enrichment of the fuel. Apart from 239 Pu and 235 U, many other nuclides give minor contributions to the SINRD signature, especially at burnup higher than 20 GWd/tHM.

  6. Comparative study between optical densitometry and spectrophotometry for evaluation of PMMA dosimeters

    International Nuclear Information System (INIS)

    Louback, Luana Trevenzoli; Meira-Belo, Luiz C.

    2011-01-01

    The use of dosimetric systems based on color changes in PMMA is standardized by ISO/ASTM 51276:2002(E). In a general way, the evaluation of doses in these materials is done correlating the optical absorbance of the material and the absorbed dose. Usually, the absorbance is measured using a spectrophotometer at a wavelength suitably chosen. In the present work, it was performed a comparative study between the techniques of spectrophotometry and optical densitometry in dyed PMMA dosimeters type Harwell RED 4034 and PMMA samples commercially available in Brazil. The main results of this study were the determination of the radiochromic response for different samples of PMMA and the determination of the calibration conditions using a 60 Co beam. The studied materials are suitable for use as routine dosimeters, covering the range of the 500Gy to 100kGy. A direct comparison between the red dyed PMMA and the Harwell RED 4034 Perspex showed that the stabilization time and the fading of the radiochromic information in red dyed PMMA samples is higher than in RED 4034. However, both effects occur on period of weeks, which does not preclude its routine use. Furthermore, the increase in absorbance due to exposure to radiation, determined by the difference between specific absorbance of the irradiated sample and a non-irradiated one, is significantly higher in PMMA with red dyed that the RED 4034. In fact, the amplitude of absorbance peak of a sample irradiated with red dyed PMMA 2kGy and read at 602nm has the same order of magnitude from a peak of RED 4034 irradiated with 10 kGy and read at 640nm. A direct consequence of this fact is the real possibility of using simpler equipment (optical densitometer in this case) to measure the optical absorbance and evaluates the absorbed dose. (author)

  7. Comparison of bone densitometry of the phalanges, distal forearm and axial skeleton in early postmenopausal women participating in the EPIC Study

    DEFF Research Database (Denmark)

    Ravn, Pernille; Overgaard, K; Huang, C

    1996-01-01

    We present baseline bone densitometry from the Early Postmenopausal Interventional Cohort study (EPIC, sponsored by Merck, Sharp & Dohme) for the first time, in which 1609 women from England, Oregon, Hawaii and Denmark are participating to investigate the efficacy of daily oral alendronate...... forearm. In a random subgroup of 308 women, aged 45-60 years, on average 6 years since menopause (YSM), bone densitometry was measured once at baseline by RA of the phalanges besides the mandatory measurements by DXA. Bone densitometry was furthermore measured by SXA at the Danish site (89 women). Sixty......-eight of the women had duplicate measurements performed within 1-3 weeks to evaluate the short-term precision error (CV%). One hundred and one healthy premenopausal women, aged 25-48 years, were recruited at the Danish and Hawaiian sites to establish a reference group. The precision error was 1.5% for RA...

  8. Cost-effectiveness of bone densitometry among Caucasian women and men without a prior fracture according to age and body weight.

    Science.gov (United States)

    Schousboe, J T; Gourlay, M; Fink, H A; Taylor, B C; Orwoll, E S; Barrett-Connor, E; Melton, L J; Cummings, S R; Ensrud, K E

    2013-01-01

    We used a microsimulation model to estimate the threshold body weights at which screening bone densitometry is cost-effective. Among women aged 55-65 years and men aged 55-75 years without a prior fracture, body weight can be used to identify those for whom bone densitometry is cost-effective. Bone densitometry may be more cost-effective for those with lower body weight since the prevalence of osteoporosis is higher for those with low body weight. Our purpose was to estimate weight thresholds below which bone densitometry is cost-effective for women and men without a prior clinical fracture at ages 55, 60, 65, 75, and 80 years. We used a microsimulation model to estimate the costs and health benefits of bone densitometry and 5 years of fracture prevention therapy for those without prior fracture but with femoral neck osteoporosis (T-score ≤ -2.5) and a 10-year hip fracture risk of ≥3%. Threshold pre-test probabilities of low BMD warranting drug therapy at which bone densitometry is cost-effective were calculated. Corresponding body weight thresholds were estimated using data from the Study of Osteoporotic Fractures (SOF), the Osteoporotic Fractures in Men (MrOS) study, and the National Health and Nutrition Examination Survey (NHANES) for 2005-2006. Assuming a willingness to pay of $75,000 per quality adjusted life year (QALY) and drug cost of $500/year, body weight thresholds below which bone densitometry is cost-effective for those without a prior fracture were 74, 90, and 100 kg, respectively, for women aged 55, 65, and 80 years; and were 67, 101, and 108 kg, respectively, for men aged 55, 75, and 80 years. For women aged 55-65 years and men aged 55-75 years without a prior fracture, body weight can be used to select those for whom bone densitometry is cost-effective.

  9. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  10. Performance assessment of self-interrogation neutron resonance densitometry for spent nuclear fuel assay

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianwei, E-mail: huj1@ornl.gov [Reactor and Nuclear Systems Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, PO Box 2008, MS-6172, Oak Ridge, TN 37831-6172 (United States); Tobin, Stephen J.; LaFleur, Adrienne M.; Menlove, Howard O.; Swinhoe, Martyn T. [Nuclear Engineering and Nonproliferation Division, Los Alamos National Laboratory (United States)

    2013-11-21

    Self-Interrogation Neutron Resonance Densitometry (SINRD) is one of several nondestructive assay (NDA) techniques being integrated into systems to measure spent fuel as part of the Next Generation Safeguards Initiative (NGSI) Spent Fuel Project. The NGSI Spent Fuel Project is sponsored by the US Department of Energy's National Nuclear Security Administration to measure plutonium in, and detect diversion of fuel pins from, spent nuclear fuel assemblies. SINRD shows promising capability in determining the {sup 239}Pu and {sup 235}U content in spent fuel. SINRD is a relatively low-cost and lightweight instrument, and it is easy to implement in the field. The technique makes use of the passive neutron source existing in a spent fuel assembly, and it uses ratios between the count rates collected in fission chambers that are covered with different absorbing materials. These ratios are correlated to key attributes of the spent fuel assembly, such as the total mass of {sup 239}Pu and {sup 235}U. Using count rate ratios instead of absolute count rates makes SINRD less vulnerable to systematic uncertainties. Building upon the previous research, this work focuses on the underlying physics of the SINRD technique: quantifying the individual impacts on the count rate ratios of a few important nuclides using the perturbation method; examining new correlations between count rate ratio and mass quantities based on the results of the perturbation study; quantifying the impacts on the energy windows of the filtering materials that cover the fission chambers by tallying the neutron spectra before and after the neutrons go through the filters; and identifying the most important nuclides that cause cooling-time variations in the count rate ratios. The results of these studies show that {sup 235}U content has a major impact on the SINRD signal in addition to the {sup 239}Pu content. Plutonium-241 and {sup 241}Am are the two main nuclides responsible for the variation in the count

  11. Expected count rate for the Self- Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium); Borella, Alessandro; Van der Meer, Klaas [SCK.CEN, Belgian Nuclear Research Centre, Boeretang, 200 - B2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in the fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron flux integrated over the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach considered in this study consists in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types are used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the count rate that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of count rate and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the count rate by increasing the detector size. The study shows that the highest count rate is achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the count rate associated to each detector type

  12. Simultaneous determination of five active compounds in chimonanthus nitens by double-development HPTLC and scanning densitometry

    Directory of Open Access Journals (Sweden)

    Zhou Bin

    2012-05-01

    Full Text Available Abstract Background Chimonanthus nitens (family Calycanthaceae, Shanlamei in Chinese, is an unique species in China. The extract of dried leaves of Chimonanthus nitens has anti-inflammatory, antipyretic and antitussive effects. Terpenes, coumarins, and flavonoids are usually regarded as the main active components. Therefore, simultaneous determination of these compounds is very important to control the quality of Chimonanthus nitens. Results A double-development TLC method was developed for simultaneous analysis of five compounds in Chimonanthus nitens. The chromatography was performed on silica gel 60 plate with chloroform-methanol (9∶1, v/v and petroleum ether-ethyl acetate (10∶1, v/v as mobile phase for twice development. Their characteristic TLC profiles were observed under UV light at 365 nm and the bands were then revealed by reaction with 1% vanillin-H2SO4 solution. Quantification of three monoterpenes was achieved by densitometry at 545 nm (β-caryophyllene or 606 nm (cineole and linalool. Two coumarins (scopoletin and scoparone were determined by densitometry at 340 nm with filter wavelength of 370 nm. The investigated compounds had good linearity (R2 >0.99 within test ranges. Conclusions The developed double-development TLC method is helpful to control the quality of Chimonanthus nitens, which is simple and accurate.

  13. Dual-modality and dual-energy gamma ray densitometry of petroleum products using an artificial neural network

    International Nuclear Information System (INIS)

    Roshani, G.H.; Feghhi, S.A.H.; Setayeshi, S.

    2015-01-01

    The prediction of volume fractions in order to measure the multiphase flow rate is a very important issue and is the key parameter of multi-phase flow meters (MPFMs). Currently, the gamma ray attenuation technique is known as one of the most precise methods for obtaining volume fractions. The gamma ray attenuation technique is based on the mass attenuation coefficient, which is sensitive to density changes; density is sensitive in turn to temperature and pressure fluctuations. Therefore, MPFM efficiency depends strongly on environmental conditions. The conventional solution to this problem is the periodical recalibration of MPFMs, which is a demanding task. In this study, a method based on dual-modality densitometry and artificial intelligence (AI) is presented, which offers the advantage of the measurement of the oil–gas–water volume fractions independent of density changes. For this purpose, several experiments were carried out and used to validate simulated dual modality densitometry results. The reference density point was established at a temperature of 20 °C and pressure of 1 bar. To cover the full range of likely density fluctuations, four additional density sets were defined (at changes of ±4% and ±8% from the reference point). An annular regime with different percentages of oil, gas and water at different densities was simulated. Four features were extracted from the transmission and scattered detectors and were applied to the artificial neural network (ANN) as inputs. The input parameters included the "2"4"1Am full energy peak, "1"3"7Cs Compton edge, "1"3"7Cs full energy peak and total scattered count, and the outputs were the oil and air percentages. A multi-layer perceptron (MLP) neural network was used to predict the volume fraction independent of the oil and water density changes. The obtained results show that the proposed ANN model achieved good agreement with the real data, with an estimated root mean square error (RMSE) of less than 3

  14. Effect of chronic smoking on lens nucleus as assessed by Pentacam HR lens densitometry in young adults.

    Science.gov (United States)

    Pekel, Gökhan; Cetin, Ebru Nevin; Acer, Semra; Yagci, Ramazan; Altintas, Seher; Ongun, Gülin Tugba

    2014-06-01

    To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Prospective cross-sectional case series. Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (≥10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Mean age of the patients for both groups was 28.90 ± 8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean "peak" LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67 ± 0.61, Group 2: 8.44 ± 0.70, p = 0.04). The mean Schirmer test value was 12.43 ± 5.60 mm in Group 1 and 13.00 ± 4.26 mm in Group 2 (p = 0.55). The mean central corneal thickness (CCT) value was 564.23 ± 34.61 µm in Group 1 and 550.47 ± 32.94 µm in Group 2 (p = 0.03). The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group.

  15. Changes in dynamic embryonic heart wall motion in response to outflow tract banding measured using video densitometry

    Science.gov (United States)

    Stovall, Stephanie; Midgett, Madeline; Thornburg, Kent; Rugonyi, Sandra

    2016-11-01

    Abnormal blood flow during early cardiovascular development has been identified as a key factor in the pathogenesis of congenital heart disease; however, the mechanisms by which altered hemodynamics induce cardiac malformations are poorly understood. This study used outflow tract (OFT) banding to model increased afterload, pressure, and blood flow velocities at tubular stages of heart development and characterized the immediate changes in cardiac wall motion due to banding in chicken embryo models with light microscopy-based video densitometry. Optical videos were used to acquire two-dimensional heart image sequences over the cardiac cycle, from which intensity data were extracted along the heart centerline at several locations in the heart ventricle and OFT. While no changes were observed in the synchronous contraction of the ventricle with banding, the peristaltic-like wall motion in the OFT was significantly affected. Our data provide valuable insight into early cardiac biomechanics and its characterization using a simple light microscopy-based imaging modality.

  16. Investigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function

    Directory of Open Access Journals (Sweden)

    Reza Moghadam-Drodkhani

    2011-03-01

    Full Text Available Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. Therefore, in this study, the spatial resolution of two systems of film densitometry and polymer gel dosimetry based on MRI has been evaluated by using the dose modulation transfer function (DMTF.   Material and Methods: Kodak therapy verification films and MAGICA polymer gel samples were positioned below a brass absorption grid with different periodic slices (a/2= 280, 525, 1125 μm, which was placed in a water bath container to avoid regions of dose build-up just below the absorption grid and then irradiated with Cobalt-60 photons on a Theratron external-beam treatment unit. Dose variation under the brass grid was determined using a calibration curve, while transverse relaxation time (T2 as the selective parameter in a dose image based on multiple echo MRI with 1.5 Tesla GE Signa Echo Speed system (FOV=10 cm, matrix size=512 ×512, pixel size =0.199×0.199 mm2, TE = 20, 40, 60, 80 ms, TR=4200 ms, NEX = 4, slice thickness=2 mm, gap=1 mm was calculated. DMTF from the modulation depths of T2 and variation in film optical density after calibration would be achieved. The results of polymer gel were compared with film. Results: After deriving the dose distribution profile under the absorption grid, minima and maxima at the smallest period of a = 560 μm could scarcely be resolved, but the modulations due to a=2250 μm and a = 1050 μm grids could be discerned. The modulation depth for a=2250 μm grid was set to 100% and the other modulations were subsequently referred to this maximum modulation. For film densitometry at a = 1050 μm, the modulation depth was

  17. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    International Nuclear Information System (INIS)

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-01-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients

  18. Odds ratios for hip- and lower forearm fracture using peripheral bone densitometry; a case-control study of postmenopausal women

    DEFF Research Database (Denmark)

    Saleh, M M A; Jørgensen, H L; Lauritzen, J B

    2002-01-01

    concern when using peripheral densitometry is the poor correlation with the central measurements. The main aim of this study is, therefore, to assess the possibility of expressing ultrasound measurements at the heel and bone mineral density (BMD) measured at the distal forearm as fracture odds ratios...... rather than an absolute measure of bone mass. METHODS: A total of 76 women with lower forearm fracture, 47 women with hip fracture and 231 age-matched women (controls) were included. All had broadband ultrasound attenuation (BUA) and speed of sound (SOS) measured at the heel using the DTU-one ultrasound.......8; 5.2) for heel-BUA (T-score cutoff: -2.3), 4.1 (2.3; 7.4) for heel-SOS (-2.1) and 2.2 (1.3; 3.7) for lower forearm BMD (-2.7). The odds ratio for hip fracture was 3.4 (1.5-7.7) for heel-BUA (-2.7), 3.6 (1.6; 8.1) for heel-SOS (-2.6) and 3.2 (1.4; 7.4) for lower forearm BMD (-2.9). CONCLUSION...

  19. Determination of bone mineral density of the distal extremity of the radio in Rottweiller, by radiographic optic densitometry

    International Nuclear Information System (INIS)

    Alves, Jefferson Douglas Soares; Sterman, Franklin de Almeida

    2010-01-01

    This study allowed the standardization of the bone mineral density (BMD) of the distal extremity of the radio of 36 dogs adults in Rottweiler breed by radiographic optic densitometry. The limbs of the animals were radiographed with scale of aluminum that served as a reference. The radiographs images were digitalized and analyzed by a computer program for comparison of gray tones between the standard image and the image of the reference scale radiographed with the bone. Afterwards the values of density were expressed in millimeters of aluminum. Also studied the correlations between BMD and the sex, weight and external measures as the length of spine, height of the animal and circumference the distal extremity of the limb in study. The mean values and standard deviations of the bone mineral density of the distal extremity of the radio were: for the metaphyseal region the average of BMD of 7,88±0,89 mmAl, the diaphyseal region 1 the average of BMD of 8,58±0,80 mmAl and for diaphyseal region 2 of BMD of 9,00±0,74 mmAl. (author)

  20. Experiments at the GELINA facility for the validation of the self-indication neutron resonance densitometry technique

    Directory of Open Access Journals (Sweden)

    Rossa Riccardo

    2017-01-01

    Full Text Available Self-Indication Neutron Resonance Densitometry (SINRD is a passive non-destructive method that is being investigated to quantify the 239Pu content in a spent fuel assembly. The technique relies on the energy dependence of total cross sections for neutron induced reaction. The cross sections show resonance structures that can be used to quantify the presence of materials in objects, e.g. the total cross-section of 239Pu shows a strong resonance close to 0.3 eV. This resonance will cause a reduction of the number of neutrons emitted from spent fuel when 239Pu is present. Hence such a reduction can be used to quantify the amount of 239Pu present in the fuel. A neutron detector with a high sensitivity to neutrons in this energy region is used to enhance the sensitivity to 239Pu. This principle is similar to self-indication cross section measurements. An appropriate detector can be realized by surrounding a 239Pu-loaded fission chamber with appropriate neutron absorbing material. In this contribution experiments performed at the GELINA time-of-flight facility of the JRC at Geel (Belgium to validate the simulations are discussed. The results confirm that the strongest sensitivity to the target material was achieved with the self-indication technique, highlighting the importance of using a 239Pu fission chamber for the SINRD measurements.

  1. Social determinants of bone densitometry uptake for osteoporosis risk in patients aged 50yr and older: a systematic review.

    Science.gov (United States)

    Brennan, Sharon L; Wluka, Anita E; Gould, Haslinda; Nicholson, Geoffrey C; Leslie, William D; Ebeling, Peter R; Oldenburg, Brian; Kotowicz, Mark A; Pasco, Julie A

    2012-01-01

    The World Health Organization identifies that osteoporosis is one of the leading health problems in the Western world. An increased risk of fragility fracture is observed in more socially disadvantaged individuals in most Western countries. Dual-energy X-ray absorptiometry (DXA) is currently the procedure of choice to diagnose osteoporosis and assess fracture risk. We systematically reviewed the literature regarding social determinants of DXA utilization for osteoporosis detection in patients aged 50yr and older using a computer-aided search of MEDLINE, EMBASE, CINAHL, and PsychINFO from January 1994 to December 2010. Five cross-sectional studies, incorporating 16 separate analyses, were identified for inclusion in this review. The best evidence analysis identified limited evidence for a positive association between either income or education with DXA utilization; furthermore, the best evidence analysis found no evidence for an association between either marital status or working status and DXA utilization. Further research is required to identify whether a relationship exists and elucidate reasons for disparities in DXA utilization between different social groups, such as choice and referral processes, as a necessary precursor in identifying modifiable determinants and appropriate strategies to promote preventive screening to identify fracture risk. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  2. IDENTIFIKASI DAN PENETAPAN KADAR SENYAWA KUMARIN DALAM EKSTRAK METANOL Artemisia Annua L. SECARA KROMATOGRAFI LAPIS TIPIS - DENSITOMETRI

    Directory of Open Access Journals (Sweden)

    Sukmayati Alegantina

    2012-08-01

    Full Text Available Abstract. Artemisia annua L. contain the active compounds include: terpenoids, flavonoids, kumarin, artemisinin acid, artennuin B, phenols, saponins, and fat. Kumarin and its derivatives have biological activity that can stimulate skin pigment, blood anticoagulation and can inhibit the effects of carcinogens. With this biological activity of kumarin, the research is done to ensure there is kumarin by identification and measure kumarin level which is contained in the Artemisia annua L. herb. The analysis methods include the extraction and fractionation. Identification and determination of level with Thin-Layer Chromatography (TLC using a Densitometer CS-9301 PC. From the result of TLC identification of kumarin standard known that Artemisia annua L extract contain kumarin compound which marked by a blue spot flouresense on standards and methanol extract of artemisia annua L. seeing under UV light at a wavelength of 366 nm with Rf value of standard and sample is 0.31, the measurement of kumarin spot with Densitometer known that kumarin concentration in the extract of Artemisia annua L. is 10.5 ul/ ml with 105% RecoveryKeywords: Artemisia annua L, kumarin, TLC-Densitometry

  3. Neutron absorbers and detector types for spent fuel verification using the self-interrogation neutron resonance densitometry

    International Nuclear Information System (INIS)

    Rossa, Riccardo; Borella, Alessandro; Labeau, Pierre-Etienne; Pauly, Nicolas; Meer, Klaas van der

    2015-01-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive non-destructive assay (NDA) technique that is proposed for the direct measurement of 239 Pu in a spent fuel assembly. The insertion of neutron detectors wrapped with different neutron absorbing materials, or neutron filters, in the central guide tube of a PWR fuel assembly is envisaged to measure the neutron flux in the energy region close to the 0.3 eV resonance of 239 Pu. In addition, the measurement of the fast neutron flux is foreseen. This paper is focused on the determination of the Gd and Cd neutron filters thickness to maximize the detection of neutrons within the resonance region. Moreover, several detector types are compared to identify the optimal condition and to assess the expected total neutron counts that can be obtained with the SINRD measurements. Results from Monte Carlo simulations showed that ranges between 0.1–0.3 mm and 0.5–1.0 mm ensure the optimal conditions for the Gd and Cd filters, respectively. Moreover, a 239 Pu fission chamber is better suited to measure neutrons close to the 0.3 eV resonance and it has the highest sensitivity to 239 Pu, in comparison with a 235 U fission chamber, with a 3 He proportional counter, and with a 10 B proportional counter. The use of a thin Gd filter and a thick Cd filter is suggested for the 239 Pu and 235 U fission chambers to increase the total counts achieved in a measurement, while a thick Gd filter and a thin Cd filter are envisaged for the 3 He and 10 B proportional counters to increase the sensitivity to 239 Pu. We concluded that an optimization process that takes into account measurement time, filters thickness, and detector size is needed to develop a SINRD detector that can meet the requirement for an efficient verification of spent fuel assemblies

  4. Analytical Method Validation and Determination of Pyridoxine, Nicotinamide, and Caffeine in Energy Drinks Using Thin Layer Chromatography-Densitometry

    Directory of Open Access Journals (Sweden)

    Florentinus Dika Octa Riswanto

    2015-03-01

    Full Text Available Food supplement which contains vitamins and stimulants such as caffeine were classified as energy drink. TLC-densitometry method was chosen to determine the pyridoxine, nicotinamide, and caffeine in the energy drink sample. TLC plates of silica gel 60 F254 was used as the stationary phase and methanol : ethyl acetate : ammonia 25% (134:77:10 was used as the mobile phase. The correlation coefficient for each pyridoxine, nicotinamide, and caffeine were 0.9982, 0.9997, and 0.9966, respectively. Detection and quantitation limits of from the three analytes were 4.05 and 13.51 µg/mL; 13.15 and 43.83 µg/mL; 5.43 and 18.11 µg/mL, respectively. The recovery of pyridoxine, nicotinamide, and caffeine were within the required limit range of 95-105%. The percent of RSD were below the limit value of 5.7% for caffeine and nicotinamide and 8% for pyridoxine. The content amount of pyridoxine in the sample 1 and 2 were 33.59 ± 0.981 and 30.29 ± 2.061 µg/mL, respectively. The content amount of nicotinamide in the sample 1 and 2 were 106.53 ± 3.521 and 98.20 ± 3.648 µg/mL, respectively. The content amount of caffeine in the sample 1 and 2 were 249.50 ± 5.080 and 252.80 ± 2.640 µg/mL, respectively. Robustness test results showed that the most optimal method conditions should be applied for the analysis.

  5. Analysis of experimental measurements of PWR fresh and spent fuel assemblies using Self-Interrogation Neutron Resonance Densitometry

    Energy Technology Data Exchange (ETDEWEB)

    LaFleur, Adrienne M., E-mail: alafleur@lanl.gov; Menlove, Howard O., E-mail: hmenlove@lanl.gov

    2015-05-01

    Self-Interrogation Neutron Resonance Densitometry (SINRD) is a new NDA technique that was developed at Los Alamos National Laboratory (LANL) to improve existing nuclear safeguards measurements for LWR fuel assemblies. The SINRD detector consists of four fission chambers (FCs) wrapped with different absorber filters to isolate different parts of the neutron energy spectrum and one ion chamber (IC) to measure the gross gamma rate. As a result, two different techniques can be utilized using the same SINRD detector unit and hardware. These techniques are the Passive Neutron Multiplication Counter (PNMC) method and the SINRD method. The focus of the work described in this paper is the analysis of experimental measurements of fresh and spent PWR fuel assemblies that were performed at LANL and the Korea Atomic Energy Research Institute (KAERI), respectively, using the SINRD detector. The purpose of these experiments was to assess the following capabilities of the SINRD detector: 1) reproducibility of measurements to quantify systematic errors, 2) sensitivity to water gap between detector and fuel assembly, 3) sensitivity and penetrability to the removal of fuel rods from the assembly, and 4) use of PNMC/SINRD ratios to quantify neutron multiplication and/or fissile content. The results from these simulations and measurements provide valuable experimental data that directly supports safeguards research and development (R&D) efforts on the viability of passive neutron NDA techniques and detector designs for partial defect verification of spent fuel assemblies. - Highlights: • Experimental measurements of PWR fresh and spent FAs were performed with SINRD. • Good agreement of MCNPX and measured results confirmed accuracy of SINRD model. • For fresh fuel, SINRD and PNMC ratios were not sensitive to water gaps of ≤5-mm. • Practical use of SINRD would be in Fork detector to reduce systematic uncertainties.

  6. Quantitative analysis of Curcuminoid collected from different location in Indonesia by TLC-Densitometry and its antioxidant capacity

    Science.gov (United States)

    Wahyuni, D. S. C.; Artanti, A. N.; Rinanto, Y.

    2018-04-01

    Curcuminoid, consisting of curcumin, demethoxycurcumin and bis demethoxycurcumin, is the active compound in Curcuma longa L. rhizome. It yielded vary depend on the environment and varieties. Curcumin has been known to have a potent antioxidants activity. The present work was conducted to assess the curcuminoid content and antioxidant capacity in the crude extracts of C. longa L. collected from eight different locations in Indonesia. Samples were collected from eight locations including Java island, Sumatera island and Nusa Tenggara island. All samples were extracted using 96% ethanol and analyzed quantitatively using TLC-Densitometry. Antioxidant activity was assessed using diphenylpicrylhydrazyl (DPPH) radical scavenging assay and analyzed at 517 nm using a spectrophotometer. Curcuminoid content in C. longa varied among eight different locations (0.53±0.05 - 5.33±0.12 % w/w). The highest curcumin, demethoxycurcumin and bisdemethoxycurcumin yield were found in the samples from Magetan (5.33±0.12%, 1.54±0.05%, 0.46±0.02% w/w, respectively). In contrast, the lowest curcumin, demethoxycurcumin and bisdemethoxycurcumin yield were found in the sample from Demak (0.53±0.05%, 0.17±0.05%, 0.17±0.05% w/w, respectively). Antioxidant capacity showed similar for all places unless sample from Magetan which exhibited two times lower than other locations. It is apparently curcuminoid content and antioxidant activity varied among places. These results are useful information for curcuminoid standardization method in pharmaceutical products.

  7. Quality initiatives: improving patient flow for a bone densitometry practice: results from a Mayo Clinic radiology quality initiative.

    Science.gov (United States)

    Aakre, Kenneth T; Valley, Timothy B; O'Connor, Michael K

    2010-03-01

    Lean Six Sigma process improvement methodologies have been used in manufacturing for some time. However, Lean Six Sigma process improvement methodologies also are applicable to radiology as a way to identify opportunities for improvement in patient care delivery settings. A multidisciplinary team of physicians and staff conducted a 100-day quality improvement project with the guidance of a quality advisor. By using the framework of DMAIC (define, measure, analyze, improve, and control), time studies were performed for all aspects of patient and technologist involvement. From these studies, value stream maps for the current state and for the future were developed, and tests of change were implemented. Comprehensive value stream maps showed that before implementation of process changes, an average time of 20.95 minutes was required for completion of a bone densitometry study. Two process changes (ie, tests of change) were undertaken. First, the location for completion of a patient assessment form was moved from inside the imaging room to the waiting area, enabling patients to complete the form while waiting for the technologist. Second, the patient was instructed to sit in a waiting area immediately outside the imaging rooms, rather than in the main reception area, which is far removed from the imaging area. Realignment of these process steps, with reduced technologist travel distances, resulted in a 3-minute average decrease in the patient cycle time. This represented a 15% reduction in the initial patient cycle time with no change in staff or costs. Radiology process improvement projects can yield positive results despite small incremental changes.

  8. Exploring the optimum approach to the use of CT densitometry in a randomised placebo-controlled study of augmentation therapy in alpha 1-antitrypsin deficiency

    DEFF Research Database (Denmark)

    Parr, David G; Dirksen, Asger; Piitulainen, Eeva

    2009-01-01

    lung assessment. The EXAcerbations and CT scan as Lung Endpoints (EXACTLE) trial aimed to clarify the optimum approach to the use of CT densitometry data for the assessment of alpha 1-antitrypsin (AAT) augmentation therapy on the progression of emphysema in AAT deficiency (AATD). METHODS: Patients...... with AATD (n = 77) were randomised to weekly infusions of 60 mg/kg human AAT (Prolastin) or placebo over 2 to 2.5 years. Lung volume was included as a covariate in an endpoint analysis and a comparison was made of different CT densitometric indices (15th percentile lung density [PD15], mean lung density...

  9. Normal values of bone mineral density of the accessory carpus bone in Brasileiro de Hipismo (BH) horse breed using optical densitometry in radiographic image

    International Nuclear Information System (INIS)

    Godoy, C.L.B. de; Vulcano, L.C.; Santos, F.A.M.; Soares, J.C.M.

    2005-01-01

    Physiologic values of the bone mineral density (BMD) of the accessory carpal bone in Brasileiro de Hipismo (BH) horse breed were determined by radiographic optic densitometry (ROD), expressed in milimiters of alumminun (mmAl). Lateromedial radiographs of the carpus were taken from 12 intact males and 12 females, from 20 and up to 30 months of age. No significant difference was found in the average mineral bone density of the accessory carpal bone between males (4.7 ± 0.1mmAl) and females (4.,6 ± 0,1mmAl) from 20 to 30 months of age [pt

  10. Neutron absorbers and detector types for spent fuel verification using the self-interrogation neutron resonance densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo, E-mail: rrossa@sckcen.be [SCK-CEN, Belgian Nuclear Research Centre, Boeretang, 200, B2400 Mol (Belgium); Université libre de Bruxelles, Ecole polytechnique de Bruxelles, Service de Métrologie Nucléaire (CP 165/84), Avenue F.D. Roosevelt, 50, B1050 Brussels (Belgium); Borella, Alessandro, E-mail: aborella@sckcen.be [SCK-CEN, Belgian Nuclear Research Centre, Boeretang, 200, B2400 Mol (Belgium); Labeau, Pierre-Etienne, E-mail: pelabeau@ulb.ac.be [Université libre de Bruxelles, Ecole polytechnique de Bruxelles, Service de Métrologie Nucléaire (CP 165/84), Avenue F.D. Roosevelt, 50, B1050 Brussels (Belgium); Pauly, Nicolas, E-mail: nipauly@ulb.ac.be [Université libre de Bruxelles, Ecole polytechnique de Bruxelles, Service de Métrologie Nucléaire (CP 165/84), Avenue F.D. Roosevelt, 50, B1050 Brussels (Belgium); Meer, Klaas van der, E-mail: kvdmeer@sckcen.be [SCK-CEN, Belgian Nuclear Research Centre, Boeretang, 200, B2400 Mol (Belgium)

    2015-08-11

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive non-destructive assay (NDA) technique that is proposed for the direct measurement of {sup 239}Pu in a spent fuel assembly. The insertion of neutron detectors wrapped with different neutron absorbing materials, or neutron filters, in the central guide tube of a PWR fuel assembly is envisaged to measure the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. In addition, the measurement of the fast neutron flux is foreseen. This paper is focused on the determination of the Gd and Cd neutron filters thickness to maximize the detection of neutrons within the resonance region. Moreover, several detector types are compared to identify the optimal condition and to assess the expected total neutron counts that can be obtained with the SINRD measurements. Results from Monte Carlo simulations showed that ranges between 0.1–0.3 mm and 0.5–1.0 mm ensure the optimal conditions for the Gd and Cd filters, respectively. Moreover, a {sup 239}Pu fission chamber is better suited to measure neutrons close to the 0.3 eV resonance and it has the highest sensitivity to {sup 239}Pu, in comparison with a {sup 235}U fission chamber, with a {sup 3}He proportional counter, and with a {sup 10}B proportional counter. The use of a thin Gd filter and a thick Cd filter is suggested for the {sup 239}Pu and {sup 235}U fission chambers to increase the total counts achieved in a measurement, while a thick Gd filter and a thin Cd filter are envisaged for the {sup 3}He and {sup 10}B proportional counters to increase the sensitivity to {sup 239}Pu. We concluded that an optimization process that takes into account measurement time, filters thickness, and detector size is needed to develop a SINRD detector that can meet the requirement for an efficient verification of spent fuel assemblies.

  11. Gross Mal distribution Identification and Effect of Inlet Distributor on the Phase Holdup in a Trickle Bed Reactor Using Gamma-Ray Densitometry (GRD)

    International Nuclear Information System (INIS)

    Mohd Fitri Abdul Rahman; Alexander, V.; Al-Dahhan, M.

    2016-01-01

    Local liquid and gas mal distribution and their holdups in a packed column are difficult to identify due to multiphase properties and other design factors. Good liquid and gas flow distribution important to determine to get high performance of Trickle Bed Reactor (TBR). Gross mal distribution indicates some faulty or bad flow distribution of liquid and gas. In this work, gross mal distribution of phases has been identified using Gamma Ray Densitometry (GRD) technique with three types of inlet distributors (single inlet towards the wall, single inlet at the center, and proper shower) by measuring line average diameter profile of phases (Liquid, Gas, and Solids) holdups. Gamma-ray densitometry is a non-invasive technique which can be implemented at the laboratory, pilot plant, and industrial scales reactors. Experiments were performed on 0.14 m diameter reactor made of Plexiglas filled with 0.003 m glass bead which acts as the solid. The superficial velocities for both gas and liquid were in the range 0.03 m/s to 0.27 m/s and 0.004 m/s to 0.014 m/s respectively. Proper shower distributor showed early liquid spreading than compared with other distributors. The effect of superficial gas velocity on liquid spread was seen to be non-significant, and liquid distribution is found to be almost uniform at the center region of the catalyst bed. (author)

  12. Bone densitometry by dual-energy X-ray absorptiometry (DXA in preterm newborns compared with full-term peers in the first six months of life

    Directory of Open Access Journals (Sweden)

    Virginia S. Quintal

    2014-12-01

    Full Text Available OBJECTIVES: To longitudinally assess bone mineral content (BMC, bone mineral density (BMD, and whole-body lean mass obtained through bone densitometry by dual-energy X-ray absorptiometry (DXA in preterm newborns (PTNs and compare them with full-term newborns (FTNs from birth to 6 months of corrected postnatal age. METHODS: A total of 28 adequate for gestational age (AGA newborns were studied: 14 preterm and 14 full-term newborns. DXA was used to determine BMC, BMD, and lean mass in three moments: 40 weeks corrected post-conceptual age, as well as 3 and 6 months of corrected postnatal age. PTNs had gestational age ≤ 32 weeks at birth and were fed their mother's own milk or milk from the human milk bank. RESULTS: All infants had an increase in BMC, BMD, and lean body mass values during the study. PTNs had lower BMC, BMD, and lean mass at 40 weeks of corrected post-conceptual age in relation to FTNs (p < 0.001, p < 0.001, p = 0.047, respectively. However, there was an acceleration in the mineralization process of PTNs, which was sufficient to achieve the normal values of FTNs at 6 months of corrected age. CONCLUSIONS: This study suggests that bone densitometry by dual-energy X-ray absorptiometry is a good method for the assessment of body composition parameters at baseline, and at the follow-up of these PTNs.

  13. Immobilisation-induced changes in forearm bone quantity and quality: radiographic fourier image analysis vs bone densitometry

    International Nuclear Information System (INIS)

    Moore, G.; Price, R.I.; Buck, A.M.; University of Western Australia, Nedlands, WA; Price, R.L.; University of Western Australia, Nedlands, WA; Sweetman, I.M.; Ho, S.

    1996-01-01

    (including water-immersion of the forearm, plus image calibration) and results of the bone densitometry study have been published (Prince RL et al, J Bone and Min Res, 3: 305-310, 1988). In the present study, the original radiographs from a subset of 30 patients (16M and 14F) were re-analysed by specifically-designed software (IMS). Radiographs were digitised and a square (128 x 128 pixels, 256 grey levels) was extracted centrally from the image of the UD radius, with its distal side perpendicular to the forearm long axis and lined up with the base of the ulnar styloid process, representing an area of 16x16 mm 2 on the unmagnified image. Following thresholding using a value derived from sampling of the bone-free image, a 2-D FT was derived. It is reasonable to expect that there is (at least) a qualitative relationship between the sizes and orientations of the image elements identified by the FT and those of the trabeculae generating them by superposition. The general orientations (or sizes) of these periodic elements were analysed by dividing up the Fourier plane (described by polar coordinates ν, θ) into contiguous sectors (or annuli) and summing the normalised intensities within each sector (or annulus) (eg Lendaris GG et al, Proc IEEE 58: 198-216, 1970). Principal Components Analysis using all 8 annuli produced a complete separation of male and female non-hemi forearms, marked separation of male hemi and male non-hemi, and no separation in women. We conclude from this preliminary study that FT analysis of in-vivo forearm radiographs reveals gender dimorphism and detects immobilisation-induced changes in bone structure (ie 'quality') in males but not females. Thus the pattern of trabecular bone loss in males may differ from that of women, in a manner not discernible by conventional bone densitometry, which addresses bone 'quantity' only

  14. Densitometry By Acoustic Levitation

    Science.gov (United States)

    Trinh, Eugene H.

    1989-01-01

    "Static" and "dynamic" methods developed for measuring mass density of acoustically levitated solid particle or liquid drop. "Static" method, unknown density of sample found by comparison with another sample of known density. "Dynamic" method practiced with or without gravitational field. Advantages over conventional density-measuring techniques: sample does not have to make contact with container or other solid surface, size and shape of samples do not affect measurement significantly, sound field does not have to be know in detail, and sample can be smaller than microliter. Detailed knowledge of acoustic field not necessary.

  15. Bone densitometry in infants

    International Nuclear Information System (INIS)

    Barden, H.S.; Mazess, R.B.

    1988-01-01

    Bone mineral mass and density can be measured noninvasively by various absorptiometric procedures. Two methods, dual-photon absorptiometry (DPA) and quantitative computed tomography, have widespread application in adults but only limited use in children. One method, single-photon absorptiometry (SPA), has been used extensively in adults and children and has been modified for use in infants. The radius shaft has been used for most research on infants. However, the difficulty of using older SPA methods on this small bone (4 to 7 mm width) has led a few investigators to measure the shaft of the humerus. The typical precision of measurement in a newborn is about 5% with the use of computerized rectilinear scanners for the radius; older linear scanners have a precision error of 5% to 10% on the humerus. Linear scanners cannot measure precisely the radius in individual neonates. The SPA scans typically take about 5 minutes. The DPA technique using 153 Gd has been modified for use on smaller animals (5 to 10 kg monkeys and dogs), but it has not been used on infants because DPA scans take 20 minutes. New methods using x-ray absorptiometry allow rapid (1 minute), precise (1%) measurements in the perinate. The need for a soft tissue bolus is eliminated, and both the axial and peripheral skeletons can be measured with dual-energy x-ray absorptiometry. Ultrasonic measurements do not yet offer adequate precision in the neonate, given the limited biologic range of values. 83 references

  16. Qualitative and quantitative analyses of the morphological-dynamics of early cardiac pumping function using video densitometry and optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Happel, C.; Männer, J.; Thommes, J.

    has become a matter of dispute. Uncovering of the pumping mechanism of tubular embryonic hearts requires detailed information about the hemodynamics as well as morphological dynamics of the pump action. We have analyzed the morphological dynamics of cardiac pump action in chick embryos (HH-stage 16......) of the embryonic heart segments (common atrium, AV-canal, embryonic ventricles, outflow tract). Video densitometric M-mode curves show remarkable similarities to OCT M-mode recordings. OCT M-mode recordings can only be taken at one site at a time whereas video densitometry allows simultaneous recordings at any...... striking differences in contraction behavior of different heart segments of the tubular embryonic heart. These findings are important for the understanding of the pumping mechanism of the developing valveless embryonic heart....

  17. Investigation of the profile and kinetics of degradation of rivaroxaban using HPLC, TLC-densitometry and LC/MS/MS: Application to pre-formulation studies

    Directory of Open Access Journals (Sweden)

    Mohamed A. Abdallah

    2015-06-01

    Full Text Available Rivaroxaban (RIVA, an amide group-containing oral anticoagulant was subjected to stress conditions commonly required for the registration of pharmaceuticals: base and acid-catalyzed hydrolysis (0.1 M, 60 °C, 3–6 h, oxidation (10% H2O2, 24 h, photodegradation (300–800 nm, 24 h and thermal decomposition (50 °C, 6 h. Two major degradation products were separated and identified using TLC and LC/MS/MS, respectively. An orthogonal stability-indicating testing protocol (RP-HPLC and NP-TLC-densitometry was developed and validated according to ICH guidelines. Both assays enabled the determination of RIVA in the presence of its degradation products as well as the kinetics of degradation. Determination was carried out over a concentration range of (5.00–50.00 μg/mL and (0.40–12.00 μg/band with an accuracy of (100.81% ± 1.03 and (100.29% ± 1.08 for HPLC and TLC-densitometry, respectively. Results indicated that RIVA was stable towards oxidation, photodegradation and thermal decomposition but extremely sensitive to hydrolysis. Two major degradation products were detected in the case of base-catalyzed hydrolysis while only one degradation product was detected upon acid-catalyzed hydrolysis. This could be attributed to the presence of amide groups in RIVA structure of different stability profiles. The kinetics of hydrolysis was investigated in more detail and the reaction was found to follow the pseudo first order kinetics, as confirmed by the results of both HPLC and TLC-densitometric assays. The applicability of the assay for the determination of RIVA content and dissolution pattern of the innovator product as well as three generic formulations was demonstrated.

  18. Effects of Different Levels of Echinostoma caproni Miracidial Dose on Glucose and Maltose Composition of Biomphalaria glabrata Snails as Determined by High Performance Thin-Layer Chromatography-Densitometry

    Directory of Open Access Journals (Sweden)

    Dolcie DeGrandchamp

    2015-04-01

    Full Text Available The effects of 5, 25, and 40 Echinostoma caproni miracidia on the sugar content of young adult and mature adult Biomphalaria glabrata were studied using high performance thin layer chromatography (HPTLC-densitometry. Analysis was done on the snail’s digestive gland gonad complex (DGG at two and four weeks postmiracidial exposure. The sugars were extracted from the DGG using 70% ethanol and analyzed on silica gel HPTLC plates with a preadsorbent zone using 1-butanol-glacial acetic acid-diethyl ether-deionized water (27:18:5:3 mobile phase. The separated bands were then detected using alpha-naphthol-sulfuric reagent and quantified by densitometry at 515 nm. Significant differences were found in the maltose content between two and four weeks post exposure for both age groups. Additionally, significantly lower maltose and glucose levels were observed in the high exposure groups of both ages.

  19. Wood densitometry in 17th and 18th century Dutch, German, Austrian and French violins, compared to classical Cremonese and modern violins.

    Directory of Open Access Journals (Sweden)

    Berend C Stoel

    Full Text Available Classical violins produced by makers such as Antonio Stradivari and Guarneri del Gesu have long been considered the epitome of the luthier's art and the expressive tool of choice for the most celebrated violinists. It has been speculated these makers had access to wood that was unique in some way and that this was responsible for their acclaimed tonal characteristics. In an attempt to discern whether the above conjecture is true, we analyzed 17 modern and classical Dutch, German, Austrian and French violins by wood densitometry using computed tomography and correlated these results with our previous study of modern and Cremonese violins; in all studying 30 instruments of the violin family. In order to make this comparison possible we developed methods to cross calibrate results from different CT manufacturers using calibration wood pieces. We found no significant differences in median densities between modern and classical violins, or between classical violins from different origins. These results suggest that it is unlikely classical Cremonese makers had access to wood with significantly different wood density characteristics than that available to contemporaneous or modern makers.

  20. Ventilation abnormalities in obstructive airways disorder. Detection with pulmonary dynamic densitometry by means of spinal CT versus dynamic Xe-133 SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Nishigauchi, Kazuya; Kume, Norihiko; Takana, Katsuyuki; Koike, Shinji; Shimizu, Kensaku; Matsunaga, Naofumi

    1999-01-01

    The usefulness of pulmonary dynamic densitometry (PDD) acquired by spiral computed tomography (CT) to detect ventilation abnormalities in obstructive airway disorders was evaluated in comparison with dynamic xenon-133 (Xe-133) SPECT. Eight-second, continuous spiral CT scan was performed over 2-3 respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data set were reconstructed as 36 one-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by Xe-133 clearance-time on Xe-133 SPECT. Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9+24.5 HU; whereas, obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6+20.1 HU, P<0.0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In total 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance-time (r=842). PDD acquired by spiral CT is acceptable for detecting ventilation abnormalities in obstructive airways disorder. (author)

  1. Wood densitometry in 17th and 18th century Dutch, German, Austrian and French violins, compared to classical Cremonese and modern violins.

    Science.gov (United States)

    Stoel, Berend C; Borman, Terry M; de Jongh, Ronald

    2012-01-01

    Classical violins produced by makers such as Antonio Stradivari and Guarneri del Gesu have long been considered the epitome of the luthier's art and the expressive tool of choice for the most celebrated violinists. It has been speculated these makers had access to wood that was unique in some way and that this was responsible for their acclaimed tonal characteristics. In an attempt to discern whether the above conjecture is true, we analyzed 17 modern and classical Dutch, German, Austrian and French violins by wood densitometry using computed tomography and correlated these results with our previous study of modern and Cremonese violins; in all studying 30 instruments of the violin family. In order to make this comparison possible we developed methods to cross calibrate results from different CT manufacturers using calibration wood pieces. We found no significant differences in median densities between modern and classical violins, or between classical violins from different origins. These results suggest that it is unlikely classical Cremonese makers had access to wood with significantly different wood density characteristics than that available to contemporaneous or modern makers.

  2. Simulated Performance of the Integrated Passive Neutron Albedo Reactivity and Self-Interrogation Neutron Resonance Densitometry Detector Designed for Spent Fuel Measurement at the Fugen Reactor in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Timothy J. II [Los Alamos National Laboratory; Lafleur, Adrienne M. [Los Alamos National Laboratory; Menlove, Howard O. [Los Alamos National Laboratory; Swinhoe, Martyn T. [Los Alamos National Laboratory; Tobin, Stephen J. [Los Alamos National Laboratory; Seya, Michio [Los Alamos National Laboratory; Bolind, Alan M. [Los Alamos National Laboratory

    2012-07-16

    An integrated nondestructive assay instrument, which combined the Passive Neutron Albedo Reactivity (PNAR) and the Self-Interrogation Neutron Resonance Densitometry (SINRD) techniques, is the research focus for a collaborative effort between Los Alamos National Laboratory (LANL) and the Japanese Atomic Energy Agency as part of the Next Generation Safeguard Initiative. We will quantify the anticipated performance of this experimental system in two physical environments: (1) At LANL we will measure fresh Low Enriched Uranium (LEU) assemblies for which the average enrichment can be varied from 0.2% to 3.2% and for which Gd laced rods will be included. (2) At Fugen we will measure spent Mixed Oxide (MOX-B) and LEU spent fuel assemblies from the heavy water moderated Fugen reactor. The MOX-B assemblies will vary in burnup from {approx}3 GWd/tHM to {approx}20 GWd/tHM while the LEU assemblies ({approx}1.9% initial enrichment) will vary from {approx}2 GWd/tHM to {approx}7 GWd/tHM. The estimated count rates will be calculated using MCNPX. These preliminary results will help the finalization of the hardware design and also serve a guide for the experiment. The hardware of the detector is expected to be fabricated in 2012 with measurements expected to take place in 2012 and 2013. This work is supported by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.

  3. The usefulness of whole body bone mineral densitometry in the osteopenia of preterm infants: comparison with the wrist radiography and biochemical parameters

    International Nuclear Information System (INIS)

    Cheon, Bong Jin; Huh, Jin Do; Shin, Sang Bum; Cheon, Byung Kook; Joh, Young Duk; Kwon, Jeong Mi; Jeon, Seong Sook

    1997-01-01

    To evaluate the usefulness of whole body bone mineral densitometry in the diagnosis of frequent osteopenia of preterm infants by comparison with the wrist radiographs and biochemical parameters. From January 1995 to January 1996, we obtained whole body bone mineral density(BMD) studies using dual energy X-ray absorptiometry(DXA) and wrist radiographs of 39 preterm infants. They were divided into three groups according to birth weight, under 1500g, 1501g to 2000g and above 2000g, and four grades of skeletal change, as seen on wrist radiography, according to the scoring method of Koo et al. Groups of birth weight and grades of skeletal change were then correlated with whole body BMD and biochemical parameters. For comparison, normal data were obtained from 13 infants born at full term. Data were analyzed by one way analysis of variation(ANOVA) and correlation and regression analysis. A p-value of less than 0.05 was considered significant. Whole body BMDs were significantly lower in the more premature and smaller birth weight infants(r=0.77, p=0.0000), and in the higher grade of skeletal change(r-0.5276, p=0.0000). Aggravated skeletal changes were found in infants with lower birth weight(r= -0.3822, p=0.01). Interobserver variation in grading skeletal change was 42.9%, and intraobserver variation was 18.4%. Biochemical parameters such as serum calcium, phosphate, alkaline phosphatase, parathromone, calcitonin and 25-hydroxy-vitamine D did not vary significantly according to either birth weight or skeletal change(p > 0.05). Premature osteopenia is more effectively diagnosed by measuring whole body BMD using DXA than by grading radiographical skeletal change or by biochemical parameters

  4. The usefulness of whole body bone mineral densitometry in the osteopenia of preterm infants: comparison with the wrist radiography and biochemical parameters

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Bong Jin; Huh, Jin Do; Shin, Sang Bum; Cheon, Byung Kook; Joh, Young Duk [Kosin Univ. Gospel Hospital, Pusan (Korea, Republic of); Kwon, Jeong Mi; Jeon, Seong Sook [Ilsin Christian Hospital, Pusan (Korea, Republic of)

    1997-02-01

    To evaluate the usefulness of whole body bone mineral densitometry in the diagnosis of frequent osteopenia of preterm infants by comparison with the wrist radiographs and biochemical parameters. From January 1995 to January 1996, we obtained whole body bone mineral density(BMD) studies using dual energy X-ray absorptiometry(DXA) and wrist radiographs of 39 preterm infants. They were divided into three groups according to birth weight, under 1500g, 1501g to 2000g and above 2000g, and four grades of skeletal change, as seen on wrist radiography, according to the scoring method of Koo et al. Groups of birth weight and grades of skeletal change were then correlated with whole body BMD and biochemical parameters. For comparison, normal data were obtained from 13 infants born at full term. Data were analyzed by one way analysis of variation(ANOVA) and correlation and regression analysis. A p-value of less than 0.05 was considered significant. Whole body BMDs were significantly lower in the more premature and smaller birth weight infants(r=0.77, p=0.0000), and in the higher grade of skeletal change(r-0.5276, p=0.0000). Aggravated skeletal changes were found in infants with lower birth weight(r= -0.3822, p=0.01). Interobserver variation in grading skeletal change was 42.9%, and intraobserver variation was 18.4%. Biochemical parameters such as serum calcium, phosphate, alkaline phosphatase, parathromone, calcitonin and 25-hydroxy-vitamine D did not vary significantly according to either birth weight or skeletal change(p > 0.05). Premature osteopenia is more effectively diagnosed by measuring whole body BMD using DXA than by grading radiographical skeletal change or by biochemical parameters.

  5. Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Jonna Elizabeth [Iowa State Univ., Ames, IA (United States)

    2016-10-25

    This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

  6. Differences in distribution of T-scores and Z-scores among bone densitometry tests in postmenopausal women (a comparative study)

    International Nuclear Information System (INIS)

    Wendlova, J.

    2002-01-01

    To determine the character of T-score and Z-score value distribution in individually selected methods of bone densitometry and to compare them using statistical analysis. We examined 56 postmenopausal women with an age between 43 and 68 years with osteopenia or osteoporosis according to the WHO classification. The following measurements were made in each patient: T-score and Z-score for: 1) Stiffness index (S) of the left heel bone, USM (index). 2) Bone mineral density of the left heel bone (BMDh), DEXA (g of Ca hydroxyapatite per cm 2 ). 3) Bone mineral density of trabecular bone of the L1 vertebra (BMDL1). QCT (mg of Ca hydroxyapatite per cm 3 ). The densitometers used in the study were: ultrasonometer to measure heel bone, Achilles plus LUNAR, USA: DEXA to measure heel bone, PIXl, LUNAR, USA: QCT to measure the L1 vertebra, CT, SOMATOM Plus, Siemens, Germany. Statistical analysis: differences between measured values of T-scores (Z-scores) were evaluated by parametric or non-parametric methods of determining the 95 % confidence intervals (C.I.). Differences between Z-score and T-score values for compared measurements were statistically significant; however, these differences were lower for Z-scores. Largest differences in 95 % C.I., characterizing individual measurements of T-score values (in comparison with Z-scores), were found for those densitometers whose age range of the reference groups of young adults differed the most, and conversely, the smallest differences in T-score values were found when the differences between the age ranges of reference groups were smallest. The higher variation in T-score values in comparison to Z-scores is also caused by a non-standard selection of the reference groups of young adults for the QCT, PIXI and Achilles Plus densitometers used in the study. Age characteristics of the reference group for T-scores should be standardized for all types of densitometers. (author)

  7. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... made of metal. Objects such as keys or wallets that would be in the area being scanned should be removed. You will ... and are often available in drugstores and on mobile health vans in the community. The pDEXA device is much smaller than ...

  8. Quantitative densitometry of neurotransmitter receptors

    International Nuclear Information System (INIS)

    Rainbow, T.C.; Bleisch, W.V.; Biegon, A.; McEwen, B.S.

    1982-01-01

    An autoradiographic procedure is described that allows the quantitative measurement of neurotransmitter receptors by optical density readings. Frozen brain sections are labeled in vitro with [ 3 H]ligands under conditions that maximize specific binding to neurotransmitter receptors. The labeled sections are then placed against the 3 H-sensitive LKB Ultrofilm to produce the autoradiograms. These autoradiograms resemble those produced by [ 14 C]deoxyglucose autoradiography and are suitable for quantitative analysis with a densitometer. Muscarinic cholinergic receptors in rat and zebra finch brain and 5-HT receptors in rat brain were visualized by this method. When the proper combination of ligand concentration and exposure time are used, the method provides quantitative information about the amount and affinity of neurotransmitter receptors in brain sections. This was established by comparisons of densitometric readings with parallel measurements made by scintillation counting of sections. (Auth.)

  9. Determination of bone mineral density of the distal extremity of the radio in Rottweiller, by radiographic optic densitometry;Determinacao da densidade mineral ossea da extremidade distal do radio de caes da raca Rottweiller, por meio da densitometria optica radiografica

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Jefferson Douglas Soares, E-mail: radiologia@unifeob.edu.b [Fundacao de Ensino Octavio Bastos (UNIFEOB), Sao Joao da Boa Vista, SP (Brazil). Fac. de Medicina e Veterinaria; Sterman, Franklin de Almeida [Universidade de Sao Paulo (USP), Butanta, SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia

    2010-06-15

    This study allowed the standardization of the bone mineral density (BMD) of the distal extremity of the radio of 36 dogs adults in Rottweiler breed by radiographic optic densitometry. The limbs of the animals were radiographed with scale of aluminum that served as a reference. The radiographs images were digitalized and analyzed by a computer program for comparison of gray tones between the standard image and the image of the reference scale radiographed with the bone. Afterwards the values of density were expressed in millimeters of aluminum. Also studied the correlations between BMD and the sex, weight and external measures as the length of spine, height of the animal and circumference the distal extremity of the limb in study. The mean values and standard deviations of the bone mineral density of the distal extremity of the radio were: for the metaphyseal region the average of BMD of 7,88+-0,89 mmAl, the diaphyseal region 1 the average of BMD of 8,58+-0,80 mmAl and for diaphyseal region 2 of BMD of 9,00+-0,74 mmAl. (author)

  10. Effect of combined treatment with calcitonin on bone densitometry of patients with treated hypothyroidism Influência da terapêutica associada com calcitonina sobre a densitometria óssea de pacientes com hipotiroidismo tratado

    Directory of Open Access Journals (Sweden)

    F. J. da C. Stamato

    2000-06-01

    Full Text Available INTRODUCTION: Thyroid hormones (TH may affect bone metabolism and turnover, inducing a loss of bone mass among hyperthyroid and in hypothyroid patients under hormone replacement treatment. Thyroid dysfunction leads to changes in the dynamics of parathyroid hormone (PTH and calcitonin (CT secretion. OBJECTIVE: The objective of the study was to determine the usefulness of CT as adjuvant therapy in the prevention of bone loss during the treatment of hypothyroidism. MATERIAL AND METHODS: We studied 16 female patients with recently diagnosed primary hypothyroidism, divided into two groups: group G1 (n=8 submitted to treatment with thyroxine (L-T4, and Group 2 (n=8 that, in addition to being treated with L-T4, received a nasal CT spray. All patients were submitted to determination of TSH, free T4, bone mineral densitometry (BMD and total bone calcium (TBC at the time of diagnosis, after 6 to 9 months of treatment, and after 12 months of treatment. RESULTS: No statistical significant differences were detected in either group between the total BMD values obtained for the femur and lumbar spine before and after treatment. However, group G1 presented a statistical significant TBC loss after 12 months of treatment compared to initial values. In contrast, no TBC loss was observed in the group treated with LT-4 in combination with CT, a fact that may suggest that CT was responsible for the lower bone reabsorption during treatment of hypothyroidism.INTRODUÇÃO: Os hormônios tiroidianos (HT podem influenciar o metabolismo e o "turnover" ósseo, induzindo perda de massa óssea em hipertiróideos e em hipótiroideos na vigência de reposição hormonal. As disfunções tiroidianas levam a alterações na dinâmica de secreção de paratormônio (PTH e de calcitonina (CT. OBJETIVO: Esclarecer a utilidade da CT como terapêutica coadjuvante na prevenção de perda óssea durante o tratamento do hipotiroidismo. MATERIAL E MÉTODOS: Dezeseis pacientes do sexo

  11. Study of bone densitometry of mongrel dogs comparing the methods of immersion and radiological densitometry

    International Nuclear Information System (INIS)

    Grossklauss, D.B.B.S.; Hormaza, J.M.; Rezende, M.A.; Costa, V.E.; Lima, A.; Machado, V.M.V.

    2011-01-01

    Bone quality is related to the effects of skeletal factors that contribute to resistance, however, can not be judged by measures of mass, but rather by its density. Bone density (BD) is a biophysical parameter of paramount importance, experimental clinic, because it assesses the process of bone mineralization. Calcium is the most abundant mineral in the skeletal system and this is associated with several metabolic functions, such as bone growth. Several pathologies in vertebrates are associated with bone structure that directly affects the locomotor system. Being an endoskeleton, the diagnosis of these diseases becomes abstruse in vivo. Physical characterization of the bone structure of healthy animals post mortem is a valuable tool for comparative diagnosis of animals in vivo. On this basis the project aims to evaluate, discuss and compare the methodologies of radiological density and immersion in water. Concomitantly, the immersion method (IM) is used to evaluate the effect of weight, sex, age and calcium content in bone tissue of the canine strain, correlating with the bone density of the right forelimb region of the humerus-radio-ulnar. (Author)

  12. Utilização da densitometria óssea como método de avaliação dos resultados da utilização de BMP bovina em artrodese de coluna em coelhos Bone densitometry in the evaluation of the results obtained with the use of bovine BMP in spine arthrodesis in rabbits

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Moura Machado

    2005-01-01

    do osso normal nos dois grupos.The object of this study is to evaluate the use of the bone densitometry as an evaluation method of the bone increment observed when we used bovine BMP in intertransverse arthrodesis of the rabbits' lumbar spine. Since the discovery of the BMP bone inductive properties, countless experimental models have been proposed. This caused the need of setting up evaluation methods to make possible a better understanding of the found results. Twenty female rabbits from New Zealand, divided in two groups, were submitted to the intertransverse arthrodesis of the lumbar column, segment L5/L6, posterior side. In the first group it was used autologous graft and in the second an association of autologous graft with biocompound (bovine BMP, 1.0 mg and hydroxyapatite, 9.0 mg. The animals were maintained in captivity, isolated and after 15 weeks submitted to the execution of bone densitometry by computerized tomography. 268 bone density measures of the normal bone, 134 measures of the newly formed bone by the association of the isolated autologous graft and 134 measures of the newly formed bone by the association autologous graft and BMP were obtained, what demonstrated a significant bone increment after statistical analysis (p=0.034 of the BMP/HAP group, when compared to the control group. We found this same variation of bone density analyzing the normal bone. The bone densitometry accomplished by the computerized tomography is an alternative method to assess the results when the BMP is used in experimental studies. Further studies should be accomplished for better understanding of the bone density variation found when the measures of the normal bone in the two groups are compared.

  13. Correlação entre a ultrassonometria óssea do calcâneo e a densitometria em mulheres pós-menopausadas com fraturas por fragilidade óssea Correlation between calcaneal bone ultrasound measurements and densitometry among postmenopausal women with fractures caused by bone fragility

    Directory of Open Access Journals (Sweden)

    Frederico Barra Moraes

    2011-04-01

    Full Text Available OBJETIVO: Avaliar a correlação entre a ultrassonometria (US do calcâneo e a densitometria (DEXA em mulheres pós-menopausadas que já apresentavam uma fratura por fragilidade. MÉTODOS: Realizada coorte retrospectiva em 35 mulheres com fraturas osteoporóticas (punho ou coluna, deambulando, acima dos 40 anos, pós-menopausadas, sem tratamento prévio para osteoporose. Dessas, 16 com menos de 60 anos e 19 acima. Foram comparadas a Broadband Ultrasound Attenuation (BUA e a Speed of Sound (SOS com os sítios de DEXA (L1-L4, fêmur total, colo de fêmur e punhos, sendo utilizados dois valores de BUA diferentes como ponto de corte para osteoporose: BUA OBJECTIVE: To assess the correlation between ultrasound (US measurement on the calcaneus and bone densitometry (DEXA, among postmenopausal women who already presented fragility fractures. METHODS: 35 postmenopausal women over 40 years of age, with the ability to walk and presenting osteoporotic fractures of the wrist or spine, without previous treatment for osteoporosis, were analyzed in a retrospective cohort. Of these, 16 were under 60 and 19 were over 60. The broadband ultrasound attenuation (BUA and speed of sound (SOS were compared using DEXA (L1-L4, total femur, femoral neck and wrist. Two different values of BUA were used as cutoff points for osteoporosis: BUA < 60 dB/MHz and BUA < 64 dB/MHz (P < 0.05; and SOS < 1600 m/s. The confidence interval was 95%. The DEXA and US data were plotted on dispersion graphs and, through linear regression, it was possible to establish correlations. Following this, the sample was stratified according to age (up to 60 years and 60 years and over. Thus, the values were again compared and correlated. RESULTS: The best correlation obtained between DEXA and US was between the T-score of the wrist and BUA < 64 dB/ MHz, with 92% sensitivity and 95% specificity. Better sensitivity at all DEXA sites was obtained when US was performed on patients over 60 years of age

  14. Comparison of bone densitometry methods in healthy and osteoporotic women

    International Nuclear Information System (INIS)

    Reinbold, W.D.; Dinkel, E.; Genant, H.K.

    1988-01-01

    To compare methods of noninvasive measurement of bone mineral content, 40 healthy early postmenopausal women and 68 postmenopausal women with osteoporosis were studied. The methods included mono- and dual-energy quantitative computed tomography (QCT) and dual-photon absorptiometry (DPA) of the lumbar spine, single-photon absorptiometry (SPA) of the distal third of the radius, and combined cortical thickness (CCT) of the second metacarpal shaft. Lateral thoracolumbar radiographic studies were performed and the spinal fracture index calculated. There was good correlation between QCT and DPA methods in early postmenopausal women and moderate correlation in postmenopausal osteoporotic women. Correlations between spinal measurements (QCT or DPA) and appendicular cortical measurements (SPA or CCT) were moderate in healthy women and poor in osteoporotic women. Measurements resulting from one method were not predictive of measurements obtained by another method for individual patients. The strongest correlation with severity of vertebral fracture was provided by QCT and the weakest by SPA. There was good correlation between single- and dual-energy QCT results. Osteoporotic women and younger healthy women can be distinguished by the measurement of spinal trabecular bone density using QCT, and this method is more sensitive than the measurement of spinal integral bone by DPA or of appendicular cortical bone by SPA or CCT. (orig.) [de

  15. Importance of lateral spine view in DEXA bone densitometry

    International Nuclear Information System (INIS)

    Hussain, R.; Khan, A.S.M.H.; Momtaz, S.; Rahman, M.U.; Jehan, A.H.

    2002-01-01

    Aim: Bone Mineral Density (BMD) measurement is an invaluable technique for assessing fracture risk in suspected cases of osteoporosis. The routine procedure includes AP spine and hip views. But quite often there are discordant results between them, bone mineral concentration (BMC) in the AP spine appears higher than hip. Our study was done to establish the importance of lateral spine view. The lateral view would provide better scope to draw the ROI perfectly and so BMC would be more accurately measured. Materials and Methods: In a prospective study a total of 60 consecutive patients (48F, 12M) were evaluated for bone densitometric measurements. The age group was 35 - 80 years (Mean 59 years). None of the patients received estrogen, biphosphonates or steroid therapy. Bone density of the hip and lumbar spine were measured with Norland XR 36. The T-score, which measures the difference between patient's BMD and young-normal was computed and age-matched Z-score were calculated. X-ray correlation was also done in most of the cases. Results: When we analyzed the femoral neck values, 30 cases were osteoporotic and 23 were osteopenic whereas according to AP spine views only 20 were osteoporotic and 30 were osteopenic. So, clearly a significant number of patients having osteoporosis were interpreted as osteopenia (P 0.05). But in the same vertebra there were significant differences (P<0.05) of BMC measured with AP and lateral views. Conclusion: The lateral view can exclude the posterior element of the vertebra as well as the aorta anteriorly, where a high incidence of calcified atherosclerotic plaques are present. AP view includes these drawbacks resulting in falsely higher BMC. Lateral spine view can eliminate these problems and so it provides an important role in BMD measurements. The authors recommend that it should be included in routine practice

  16. Bone densitometry in pediatric patients treated with pamidronate

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, Leslie E.; Kecskemethy, Heidi H.; Harcke, H.Theodore [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Department of Medical Imaging, P.O. Box 269, Wilmington, DE (United States); Bachrach, Steven J. [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Division of General Pediatrics, P.O. Box 269, Wilmington, DE (United States); McKay, Charles [Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Division of Nephrology, P.O. Box 269, Wilmington, DE (United States)

    2005-05-01

    To determine the effect of intravenous pamidronate on the bone mineral density of children with osteogenesis imperfecta and spastic quadriplegic cerebral palsy. Charts of 38 children with osteogenesis imperfecta (n=20) and spastic quadriplegic cerebral palsy (n=18) treated with pamidronate were retrospectively reviewed. Patients were selected for treatment because of prior fracture and/or abnormally low bone mineral density. All received intravenous pamidronate at two-month to eight-month intervals and were periodically examined using dual energy X-ray absorptiometry. All patients had abnormally low bone mineral density prior to treatment. Lumbar spine bone mineral density and z-scores showed serial improvement in 31 of 32 patients. Spine bone mineral density increased 78{+-}38.1% in OI and 47.4{+-}39.0% in children with cerebral palsy. The area of greatest lateral distal femur bone mineral density improvement was in the metaphysis adjacent to the growth plate, with a 96{+-}87.8% improvement in the osteogenesis imperfecta group and 65.7{+-}55.2% improvement in the cerebral palsy group. Increases in bone mineral density exceeded that expected for age-specific growth. This was demonstrated by improvement in both spine and femur z-scores for both groups. No children with spastic quadriplegic cerebral palsy experienced fractures after the first week of treatment, whereas patients with osteogenesis imperfecta continued to have fractures but at a decreased rate. (orig.)

  17. Bone densitometry in pediatric patients treated with pamidronate

    International Nuclear Information System (INIS)

    Grissom, Leslie E.; Kecskemethy, Heidi H.; Harcke, H.Theodore; Bachrach, Steven J.; McKay, Charles

    2005-01-01

    To determine the effect of intravenous pamidronate on the bone mineral density of children with osteogenesis imperfecta and spastic quadriplegic cerebral palsy. Charts of 38 children with osteogenesis imperfecta (n=20) and spastic quadriplegic cerebral palsy (n=18) treated with pamidronate were retrospectively reviewed. Patients were selected for treatment because of prior fracture and/or abnormally low bone mineral density. All received intravenous pamidronate at two-month to eight-month intervals and were periodically examined using dual energy X-ray absorptiometry. All patients had abnormally low bone mineral density prior to treatment. Lumbar spine bone mineral density and z-scores showed serial improvement in 31 of 32 patients. Spine bone mineral density increased 78±38.1% in OI and 47.4±39.0% in children with cerebral palsy. The area of greatest lateral distal femur bone mineral density improvement was in the metaphysis adjacent to the growth plate, with a 96±87.8% improvement in the osteogenesis imperfecta group and 65.7±55.2% improvement in the cerebral palsy group. Increases in bone mineral density exceeded that expected for age-specific growth. This was demonstrated by improvement in both spine and femur z-scores for both groups. No children with spastic quadriplegic cerebral palsy experienced fractures after the first week of treatment, whereas patients with osteogenesis imperfecta continued to have fractures but at a decreased rate. (orig.)

  18. Aging and bone. X-ray bone densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Rikushi (Shiga Univ. of Medical Sciences, Otsu (Japan))

    1994-01-01

    Bone mass at all ages of the individuals is the integration of genetic factors, nutrition, physical exercise, hormonal environments, and other factors influencing the bone. It is also a measurable risk factor for osteoporosis which may subsequently cause bone fractures. Thus measuring bone mass is required to predict the probability of developing bone fractures subsequent to osteoporosis, and to diagnose osteoporosis, and to manage the osteoporosis patient. This paper discusses bone mineral measurements according to their characteristics and clinical application. Methodology for measuring bone mass has rapidly progressed during the past 15 years, which covers photodensitometry, photon absorptiometry (single energy X-ray absorptiometry and dual energy X-ray absorptiometry), quantitative CT, and ultrasound. These techniques have allowed noninvasive measurement of bone mineral density in any site of the skeleton with high accuracy and precision, although a single use of the technique cannot satisfy the complete clinical requirements. Thus the most appropriate method for measuring bone mineral density is important to monitor bone mass change and according to the specific site. (N.K.).

  19. Methods and application of bone densitometry in clinical diagnosis

    International Nuclear Information System (INIS)

    Wahner, H.W.; Riggs, B.L.

    1986-01-01

    With the awareness of osteoporosis as a major health problem for an aging population, there is great interest in early recognition and treatment of abnormal bone loss. Effective prevention of bone loss has to occur prior to the occurrence of irreparable damage. Standard radiographic procedures are not sensitive enough for the task. Therefore, a number of alternative procedures to estimate bone loss have been developed over the years, ranging from efforts to quantitate information obtained from radiographic images to sophisticated procedures such as neutron activation analysis or procedures based on the Compton scatter phenomenon. Only two procedures, photon absorptiometry and computed tomography (CT), have emerged as applicable for routine clinical use. In photon absorptiometry the entire bone mineral (cortical and trabecular bone) of a specific skeletal site is measured. CT allows measuring of bone mineral of trabecular or cortical bone alone. Normally, bone mass reaches a maximum in the third decade and then continuously declines. This age-related bone loss is greater in women in whom an accelerated rate of loss occurs at the menopause. When bone density reaches a critical fracture threshold, skeletal fractures occur (spine, hip, and distal long bones). The age at which this critical fracture threshold is reached depends on the maximal bone mass achieved in early adulthood and the rate of loss with increasing age. With the exception of NaF, present-day therapeutic efforts only retard or prevent bone loss but do not significantly add bone mineral to the skeleton. Recognition of high-risk groups and early treatment are therefore required. 79 references

  20. Osteoporosis in clinical practice – bone densitometry and fracture risk

    African Journals Online (AJOL)

    Osteoporosis is a condition of decreased bone mass and bone density associated with an increase in fracture risk. Bone mineral density (BMD) of the lumbar spine and femur can be reliably measured by double-beam X-ray absorptiometry (DEXA), which provides a measure of bone strength. Reduction in BMD is a ...

  1. Bone densitometry in healthy cats by quantitative computed tomography

    International Nuclear Information System (INIS)

    Oliveira, D.C.; Costa, L.A.V.S.; Teixeira, M.W.; Costa, F.S.; Cardoso, M.J.L.

    2012-01-01

    The radiodensity of the trabecular bone of the lumbar vertebrae in 16 healthy adult cats was studied using quantitative computed tomography (QCT). The average radiodensity of the trabecular bone of the second lumbar vertebra was 436.1 +- 42.1 Hounsfield units. However, there was a nonhomogeneous radiodensity distribution of the vertebral body. (author)

  2. Testing of massive lead containers by gamma densitometry

    International Nuclear Information System (INIS)

    Janardhanan, S.; Dabhadkar, S.B.; Subbaratnam, T.

    1977-01-01

    A non-destructive method of testing the shielding adequacy of transport and hold-up containers for radioactive sources and waste is described. The method involves measurement of the gamma intensity transmitted through the shield by a radioactive gamma source located inside. The data obtained is used to correlate the intensity with the lead thickness and thereby detect, locate and assess the extent of damage or faults if any so that corrective action can be taken in time. Factors influencing the choice of the gamma source, its strength and means of detection are described. Methods of checking the results of measurement with calculated values are outlined. The advantages of the method, its reliability and expediency with which the method can be adopted to varying applications make it an unique application in reactor and isotopes technology. (author)

  3. Aging and bone. X-ray bone densitometry

    International Nuclear Information System (INIS)

    Morita, Rikushi

    1994-01-01

    Bone mass at all ages of the individuals is the integration of genetic factors, nutrition, physical exercise, hormonal environments, and other factors influencing the bone. It is also a measurable risk factor for osteoporosis which may subsequently cause bone fractures. Thus measuring bone mass is required to predict the probability of developing bone fractures subsequent to osteoporosis, and to diagnose osteoporosis, and to manage the osteoporosis patient. This paper discusses bone mineral measurements according to their characteristics and clinical application. Methodology for measuring bone mass has rapidly progressed during the past 15 years, which covers photodensitometry, photon absorptiometry (single energy X-ray absorptiometry and dual energy X-ray absorptiometry), quantitative CT, and ultrasound. These techniques have allowed noninvasive measurement of bone mineral density in any site of the skeleton with high accuracy and precision, although a single use of the technique cannot satisfy the complete clinical requirements. Thus the most appropriate method for measuring bone mineral density is important to monitor bone mass change and according to the specific site. (N.K.)

  4. A study of densitometry comparison among three radiographic processing solutions

    International Nuclear Information System (INIS)

    Changizi, V.; Jazayeri, E.; Talaeepour, A.

    2006-01-01

    The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and processing conditions may lead to incorrect diagnosis and re-exposure of the patient. Therefore, we studied the performance of the three different available processing solutions with dental X-ray film. Materials and Methods: Dental intraoral E-speed films, size 2 (Kodak company, USA) were used in this study. These films were developed in a manual processor using three different brands of processing solution: 1) Taifsaz (Iran), 2) Darutasvir (Iran) and 3) Agfa (Germany) for temperatures of 25 d ig C , 28 d ig C and 30 d ig C at the three different exposure times, 0.2 s, 0.25 s and 0.35 s. Performance was evaluated with respect to base plus fog, relative contrast and relative speed. Results: Darutasvir processing solution as the cheapest one showed higher base plus fog density at 25 d ig C and 30 d ig C than that of Taifsaz and Agfa solutions. Also, Darutasvir solution was found to have better relative contrast than that of the others, except for 30 d ig C at 0.25 s. Relative speed was higher in Darutsavir solution than Agfa for 25 d ig C at three exposure times used in this study, for 28 d ig C at 0.2 s and for 30 d ig C at 0.35 s. Taifsaz Processing solution was in the second order with respect to tested conditions. Conclusion: Comparison among available X-ray film processing solutions for different temperatures at different exposure times can help to maintain image quality while patient exposure and film cost are kept considerably low

  5. Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

    Science.gov (United States)

    Hinghofer-Szalkay, H.

    1986-01-01

    Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

  6. Nuclear instrumentation in Cuba and for osseous densitometry

    International Nuclear Information System (INIS)

    Marrero, M.; Lopez, B.; Bolanos, L.; Fernandez, J.L.; Cabal, A.; Medina, D.; Laria, J.; Alonso, D.

    1997-01-01

    The present job describes the technical characteristics and operation of two clinical equipment designed in Cuba, for the determination in vivo of the osseous mineral content in forearm, based on the of gamma absorption technique of a single photon. The development of these equipment and the measurements done with one of them are the first intents carried out in the country to diagnose osseous illnesses by means of this method. (author) [es

  7. Evaluation of the renal blood flow by densitometry using cine-angiograms

    International Nuclear Information System (INIS)

    Nikolaev, G.G.; Slobodzyan, B.M.; Mikhajlov, V.A.

    1983-01-01

    A method of the quantitative determination of the blood flow in the renal artery and the arterial bed of the renal parenchyma was developed basing on roentgenocinematography and subsequent densitometric analysis of a roentgenocinefilm. Advantages of the utilization of this method are considered with reference to two groups of patients with chronic pyelonephritis and hypertension without change of a vascular pattern on the angiograms. They are associated with a possibility of separate determination of the hemodynamics on topographycatly Definite zones of the renal arterial bed and hemodynamic disturbances in morphological changes of the renal vessels that are invisible on the angiogra

  8. Effect of constituent elements in wood on X-ray densitometry measurements

    International Nuclear Information System (INIS)

    Kouris, K.; Tout, R.E.; Gilboy, W.B.; Spyrou, N.M.

    1981-01-01

    Small concentrations of elements introduced into a wood matrix have been shown by calculation to measurably influence the photon mass attenuation coefficient although the corresponding changes in the physical density are negligible. This has implications in dendrochronology where the interpretation of densitometric data is based on X-ray radiographs of wood. The magnitude of such effects has been evaluated for selected elements by simulating various botanical matrices. Significant matrix to matrix differences in the mass attenuation coefficient, in the energy range of interest (5 to 25 keV), have been established as being due to variations in the mineral composition. (author)

  9. Three-dimensional densitometry imaging of diatom cells using STIM tomography

    International Nuclear Information System (INIS)

    Habchi, C.; Nguyen, D.T.; Deves, G.; Incerti, S.; Lemelle, L.; Van Vang, P. Le; Moretto, Ph.; Ortega, R.; Seznec, H.; Sakellariou, A.; Sergeant, C.; Simionovici, A.; Ynsa, M.D.; Gontier, E.; Heiss, M.; Pouthier, T.; Boudou, A.; Rebillat, F.

    2006-01-01

    Scanning transmission ion microscopy tomography (STIM-T) was carried out on diatom cells with the aim of displaying their 3D structure and performing density measurements on their silica skeleton. Two software packages were compared for data reduction: TomoRebuild, based on a simple filtered backprojection algorithm, and DISRA, an iterative program. Silicon carbide microfibres of known density were also analysed as reference specimens. Similar results were obtained with both algorithms, demonstrating the ability of STIM-T to provide density measurements at the cell level without requiring any standard calibration samples. This unique feature stresses the interest of STIM-T to accurately normalise X ray emission micro-tomography data from synchrotron radiation (SXRF: synchrotron radiation X-ray fluorescence) or ion beam sources (PIXE: particle induced X-ray emission). Possible enhancements of the DISRA code are discussed in order to facilitate its use for the reconstruction of future PIXE/STIM tomography data. A 'nanoprobe' coupled to a Singletron[reg] accelerator, allowing a spatial resolution of a few tens of nanometers, is going to be built in the coming months at the Centre d'Etudes Nucleaires de Bordeaux Gradignan (CENBG). This new facility will bring promising applications in imaging and analysis at the sub-cellular level

  10. Fundamental evaluation of bone densitometry using dual energy X-ray absorptiometry (DEXA)

    Energy Technology Data Exchange (ETDEWEB)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu (Yamanashi Medical Coll., Tamaho (Japan)) (and others)

    1990-02-01

    A newly developed instrument based on dual energy X-ray absorptiometry (DEXA), Hologic QDR-1000, was evaluated fundamentally and clinically. Image quality was quite satisfactory though radiation exposure was minimal, 780.2 nC/kg (3.024 mR) for lumbar measurement. Reproducibility of the repeated measurement of a phantom was fairly good; 0.343 CV% in a same day and 0.520 CV% in a long period. Accuracy determined by measurement of potassium phosphate solution was also satisfactory. Bone mineral densities measured by this instrument were fairly correlated with those measured by single energy quantitative CT; coefficient was 0.740 for 17 patients. Mix-DP plates of more than 10 cm thick overestimated the bone mineral densities of a phantom. Bone mineral densities of Japanese normal volunteers were in the normal range (mean {plus minus} 2SD) of the Americans though mostly lower than the mean. In patients with spondylosis deformans or prominent aortic calcification, bone mineral densities might be overestimated. Lateral view was obtainable though its reproducibility was not good. Positioning especially for measuring femoral neck was quite critical for reproducible measurement. In conclusion, this new instrument is quite accurate and satisfactory for clinical application to measuring bone mineral densities. (author).

  11. Fundamental evaluation of bone densitometry using dual energy X-ray absorptiometry (DEXA)

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Uchiyama, Guio; Araki, Tsutomu

    1990-01-01

    A newly developed instrument based on dual energy X-ray absorptiometry (DEXA), Hologic QDR-1000, was evaluated fundamentally and clinically. Image quality was quite satisfactory though radiation exposure was minimal, 780.2 nC/kg (3.024 mR) for lumbar measurement. Reproducibility of the repeated measurement of a phantom was fairly good; 0.343 CV% in a same day and 0.520 CV% in a long period. Accuracy determined by measurement of potassium phosphate solution was also satisfactory. Bone mineral densities measured by this instrument were fairly correlated with those measured by single energy quantitative CT; coefficient was 0.740 for 17 patients. Mix-DP plates of more than 10 cm thick overestimated the bone mineral densities of a phantom. Bone mineral densities of Japanese normal volunteers were in the normal range (mean ± 2SD) of the Americans though mostly lower than the mean. In patients with spondylosis deformans or prominent aortic calcification, bone mineral densities might be overestimated. Lateral view was obtainable though its reproducibility was not good. Positioning especially for measuring femoral neck was quite critical for reproducible measurement. In conclusion, this new instrument is quite accurate and satisfactory for clinical application to measuring bone mineral densities. (author)

  12. High-throughput film-densitometry: An efficient approach to generate large data sets

    Energy Technology Data Exchange (ETDEWEB)

    Typke, Dieter; Nordmeyer, Robert A.; Jones, Arthur; Lee, Juyoung; Avila-Sakar, Agustin; Downing, Kenneth H.; Glaeser, Robert M.

    2004-07-14

    A film-handling machine (robot) has been built which can, in conjunction with a commercially available film densitometer, exchange and digitize over 300 electron micrographs per day. Implementation of robotic film handling effectively eliminates the delay and tedium associated with digitizing images when data are initially recorded on photographic film. The modulation transfer function (MTF) of the commercially available densitometer is significantly worse than that of a high-end, scientific microdensitometer. Nevertheless, its signal-to-noise ratio (S/N) is quite excellent, allowing substantial restoration of the output to ''near-to-perfect'' performance. Due to the large area of the standard electron microscope film that can be digitized by the commercial densitometer (up to 10,000 x 13,680 pixels with an appropriately coded holder), automated film digitization offers a fast and inexpensive alternative to high-end CCD cameras as a means of acquiring large amounts of image data in electron microscopy.

  13. Evaluation of the normal values of bone densitometry in brazilian women population

    International Nuclear Information System (INIS)

    Alonso, G.; Martins, L.R.F.; Alonso, C.R.; Blomer, E.

    1992-01-01

    The bone mineral density (BMD) can vary according with color, sex, feed and knowing the miscegenation and nutritional state of the Brazilian people; it is obvious that the fixed values of Caucasian females BMD cannot be employed to the Brazilian women. We have studied 158 Brazilian women with average age of 42 ± 14 years in whom it was settled the BMD over the lumbar vertebral column (L2, L3 and L4) and the femoral neck with a gadolinium-153 source double-photon densitometer and analyzed images in a IBM/PC/AT 286 processor computer. It was determined the linear regression equation corresponding to the variation of the bone mineral density as a function of age. The results were: BMD-lumbar column = 1.405 - 0.0086 x age ± 0.013 g/cm 2 and BMD-femoral neck = 0.909 - 0.0034 x age ± 0.11 g/cm 2 preferred to the age group between 25 to 80 years old. The results analysis shows that the Brazilian women BMD is lesser than the Caucasian. (author)

  14. Application of the active shape model in a commercial medical device for bone densitometry

    DEFF Research Database (Denmark)

    Thodberg, Hans Henrik; Rosholm, Anders

    2003-01-01

    Osteoporosis is a common disorder characterised mainly by low bone mineral density (BMD), and leading to an increased risk of fracture. We have developed a new device that estimates BMD from ordinary hand radiographs. A crucial element of this method is the reconstruction of the metacarpals...

  15. Dosimetry and bone densitometry. Comparison between lunar 1Q and Hologic 4500A

    International Nuclear Information System (INIS)

    Philippon, B.; Duboeuf, F.; Itti, R.

    2002-01-01

    Patient dosimetry related to two bone densitometer units from different manufacturers (LUNAR IQ and HOLOGIC 4500A) were evaluated using the parallel beam technique and thermoluminescence from Ca (SO4)/Dy. The radiation dose measured for a phantom of 18 cm in thickness was 0,11 mGy (+/- 0,004) at a maximum current of 3 mA for the LUNAR IQ unit in the high-resolution mode. The radiation dose is 0,28 mGy (+/- 0,011) for the HOLOGIC 4500A unit used at 2,5 mA in the high resolution-mode. These results obtained by thermoluminescence of the Ca (SO4)/Dy are in favor of the LUNAR IQ unit. However, dosimetry must be weighted against image quality. (author)

  16. Comparison between femoral bone mineral parameters assessed by QCT and dual X-ray densitometry

    International Nuclear Information System (INIS)

    Hoeiseth, A.; Stroemsoee, K.; Alho, A.

    1995-01-01

    The aim of this study was to assess the agreement between different femoral bone mineral measures and their agreement with some biomechanical parameters. By means of quantitative CT (QCT) and dual X-ray absorptiometry (DXA), measurements were made in different locations of 33 pairs of human femur specimens. There was a principal distinction between bone density as measured by QCT and bone mass as measured by QCT and DXA. Bone mass measured by QCT and the bone mineral content (BMC) measured by DXA are true mass parameters. However, bone mineral density (BMD) as measured by DXA agreed substantially better with the mass measures than with the densities. The mass measures, including the BMD, had good agreements with each other, with a common reference parameter and with the biomechanical parameters. The QCT densities had, on the average, poor agreements with each other, with the other bone mineral measures (including the MBDs), and with the mechanical parameters. The gender differences were less for the QCT densities than for the mass parameters, whereas in this regard the BMDs were intermediate. All measures had approximately similar reproducibilities. (orig.)

  17. Estimation of capsaicin through scanning densitometry and evaluation of different varieties of capsicum in India.

    Science.gov (United States)

    Gantait, Arunava; Maji, Amal; Barman, Tapu; Banerji, Pratim; Venkatesh, P; Mukherjee, Pulok K

    2012-01-01

    Capsicum annuum L. (family: Solanaceae) possesses therapeutic benefits for the treatment of rheumatism, neuropathy, psoriasis, flatulence and so on. In this study fruits of four different varieties of C. annuum from four different geographical regions in India were evaluated based on their total content of capsaicin. Ethanol extracts of the fruits were used. HPTLC plates were developed in a mobile phase containing benzene, ethyl acetate and methanol (75:20:5). Densitometric scanning was performed at a wavelength of 283 nm in the absorbance mode. The calibration curve was described by the equation Y=393.587+3.836*X with a correlation coefficient (r) of 0.99890. The content of capsaicin in Nagaland, Manipur, West Bengal and Shimla varieties was found to be 3.71%, 1.78%, 0.54% and 0.06%, respectively. The developed densitometric method was found to be specific, accurate and precise. A recovery study and precision showed low levels of %RSD values. The linearity range of the curve for capsaicin was found to be 300-900 ng per spot. The limit of detection and the limit of quantification values were determined to be 31 and 94 ng, respectively, proving the sensitivity of the method. Thus the method can be used to control the total content of capsaicin on an industrial scale.

  18. Ultrasound and X-ray-based bone densitometry in patients with anorexia nervosa.

    Science.gov (United States)

    Resch, H; Newrkla, S; Grampp, S; Resch, A; Zapf, S; Piringer, S; Hockl, A; Weiss, P

    2000-05-01

    In 20 patients (mean age 23+/-5 years) with anorexia nervosa (AN), bone mass was evaluated by broadband ultrasound attenuation (BUA) of the calcaneus, peripheral quantitative computed tomography (pQCT) of the distal radius, and dual X-ray absorptiometry (DXA) of the lumbar spine and the hip. Compared with 20 age- and sex- matched healthy controls, patients with AN showed marked osteopenia at all measuring sites. Values of BUA (33.0+/-9 dB/MHz vs. 51.0+/-5.7 dB/MHz; P<0.0001) and of BMD of all regions of the hip (e.g., femoral neck: 0.71+/-0.13 g/cm(2) versus 0.89+/-0.07 g/cm(2); P<0.001), lumbar spine (0.82+/-0.15 g/cm(2) versus 1.24+/-0.06 g/cm(2); P<0.003) and total BMD of the peripheral radius (303.2+/-75 g/cm(3) versus 369.4+/-53.2 g/cm(3), P<0.001) were significantly reduced. Calculating a Z-score we found the most prominent differences between AN and controls by BUA of the calcaneus (-3.2+/-1.6), followed by DXA at the lumbar spine (-2.9+/-2.2) and the hip (femoral neck -2.1+/-1.7) and by pQCT at the distal radius (total BMD -1.2+/-2.0). There were highly significant correlations between BUA of the calcaneus and BMD of the femoral neck (r = 0.78, P<0.0001) and lumbar spine (r = 0.75, P<0.0001) as well as between BMD values of the femoral neck and lumbar spine (r = 0.95; P<0.0001). In addition, there were significant correlations (P<0.001) between body mass index (BMI) and the three different measuring sites and between the duration of the disease and BUA (r = 0.5, P<0.05). Our data suggest that BUA of the calcaneus is a valuable tool in the management of osteoporosis. Being a fast, radiation-free investigation method of good acceptance, it may be well suited for an assessment of the skeletal status in patients with AN.

  19. Osteoporosis pharmacotherapy following bone densitometry: importance of patient beliefs and understanding of DXA results

    DEFF Research Database (Denmark)

    Brask-Lindemann, Dorthe; Cadarette, S M; Eskildsen, P

    2011-01-01

    . Quadratic weighted kappa was used to estimate agreement between self-report and actual DXA results. Multivariable logistic regression was used to evaluate predictors of understanding of diagnosis, and correlates of treatment initiation and persistence. Results A total of 717 patients responded (72...

  20. Bone Densitometry of the Femoral Midshaft the Protein-Deprived Rat*

    African Journals Online (AJOL)

    rats, has shown a significant loss of total bone density in the protein-deprived group. This reduction is no greater than can be accounted for by the loss of cortical bone surface area, suggesting that while bone mass is reduced as a result of protein deprivation, the mineral composition of the residual bone is likely to be ...

  1. Utilization of DXA Bone Mineral Densitometry in Ontario: An Evidence-Based Analysis.

    Science.gov (United States)

    2006-01-01

    Systematic reviews and analyses of administrative data were performed to determine the appropriate use of bone mineral density (BMD) assessments using dual energy x-ray absorptiometry (DXA), and the associated trends in wrist and hip fractures in Ontario. DUAL ENERGY X-RAY ABSORPTIOMETRY BONE MINERAL DENSITY ASSESSMENT: Dual energy x-ray absorptiometry bone densitometers measure bone density based on differential absorption of 2 x-ray beams by bone and soft tissues. It is the gold standard for detecting and diagnosing osteoporosis, a systemic disease characterized by low bone density and altered bone structure, resulting in low bone strength and increased risk of fractures. The test is fast (approximately 10 minutes) and accurate (exceeds 90% at the hip), with low radiation (1/3 to 1/5 of that from a chest x-ray). DXA densitometers are licensed as Class 3 medical devices in Canada. The World Health Organization has established criteria for osteoporosis and osteopenia based on DXA BMD measurements: osteoporosis is defined as a BMD that is >2.5 standard deviations below the mean BMD for normal young adults (i.e. T-score related fragility fractures occur most often in the wrist, femur and pelvis. These fractures, particularly those in the hip, are associated with increased mortality, and decreased functional capacity and quality of life. A Canadian study showed that at 1 year after a hip fracture, the mortality rate was 20%. Another 20% required institutional care, 40% were unable to walk independently, and there was lower health-related quality of life due to attributes such as pain, decreased mobility and decreased ability to self-care. The cost of osteoporosis and osteoporotic fractures in Canada was estimated to be $1.3 billion in 1993. With 2 exceptions, almost all guidelines address only women. None of the guidelines recommend blanket population-based BMD testing. Instead, all guidelines recommend BMD testing in people at risk of osteoporosis, predominantly women aged 65 years or older. For women under 65 years of age, BMD testing is recommended only if one major or two minor risk factors for osteoporosis exist. Osteoporosis Canada did not restrict its recommendations to women, and thus their guidelines apply to both sexes. Major risk factors are age greater than or equal to 65 years, a history of previous fractures, family history (especially parental history) of fracture, and medication or disease conditions that affect bone metabolism (such as long-term glucocorticoid therapy). Minor risk factors include low body mass index, low calcium intake, alcohol consumption, and smoking. The Ontario Health Insurance Program (OHIP) Schedule presently reimburses DXA BMD at the hip and spine. Measurements at both sites are required if feasible. Patients at low risk of accelerated bone loss are limited to one BMD test within any 24-month period, but there are no restrictions on people at high risk. The total fee including the professional and technical components for a test involving 2 or more sites is $106.00 (Cdn). This review consisted of 2 parts. The first part was an analysis of Ontario administrative data relating to DXA BMD, wrist and hip fractures, and use of antiresorptive drugs in people aged 65 years and older. The Institute for Clinical Evaluative Sciences extracted data from the OHIP claims database, the Canadian Institute for Health Information hospital discharge abstract database, the National Ambulatory Care Reporting System, and the Ontario Drug Benefit database using OHIP and ICD-10 codes. The data was analyzed to examine the trends in DXA BMD use from 1992 to 2005, and to identify areas requiring improvement. The second part included systematic reviews and analyses of evidence relating to issues identified in the analyses of utilization data. Altogether, 8 reviews and qualitative syntheses were performed, consisting of 28 published systematic reviews and/or meta-analyses, 34 randomized controlled trials, and 63 observational studies. Analysis of administrative data showed a 10-fold increase in the number of BMD tests in Ontario between 1993 and 2005.OHIP claims for BMD tests are presently increasing at a rate of 6 to 7% per year. Approximately 500,000 tests were performed in 2005/06 with an age-adjusted rate of 8,600 tests per 100,000 population.Women accounted for 90 % of all BMD tests performed in the province.In 2005/06, there was a 2-fold variation in the rate of DXA BMD tests across local integrated health networks, but a 10-fold variation between the county with the highest rate (Toronto) and that with the lowest rate (Kenora). The analysis also showed that:With the increased use of BMD, there was a concomitant increase in the use of antiresorptive drugs (as shown in people 65 years and older) and a decrease in the rate of hip fractures in people age 50 years and older.Repeat BMD made up approximately 41% of all tests. Most of the people (>90%) who had annual BMD tests in a 2-year or 3-year period were coded as being at high risk for osteoporosis.18% (20,865) of the people who had a repeat BMD within a 24-month period and 34% (98,058) of the people who had one BMD test in a 3-year period were under 65 years, had no fracture in the year, and coded as low-risk.Only 19% of people age greater than 65 years underwent BMD testing and 41% received osteoporosis treatment during the year following a fracture.Men accounted for 24% of all hip fractures and 21 % of all wrist fractures, but only 10% of BMD tests. The rates of BMD tests and treatment in men after a fracture were only half of those in women.In both men and women, the rate of hip and wrist fractures mainly increased after age 65 with the sharpest increase occurring after age 80 years. SERIAL BONE MINERAL DENSITY TESTING FOR PEOPLE NOT RECEIVING OSTEOPOROSIS TREATMENT: A systematic review showed that the mean rate of bone loss in people not receiving osteoporosis treatment (including postmenopausal women) is generally less than 1% per year. Higher rates of bone loss were reported for people with disease conditions or on medications that affect bone metabolism. In order to be considered a genuine biological change, the change in BMD between serial measurements must exceed the least significant change (variability) of the testing, ranging from 2.77% to 8% for precisions ranging from 1% to 3% respectively. Progression in BMD was analyzed, using different rates of baseline BMD values, rates of bone loss, precision, and BMD value for initiating treatment. The analyses showed that serial BMD measurements every 24 months (as per OHIP policy for low-risk individuals) is not necessary for people with no major risk factors for osteoporosis, provided that the baseline BMD is normal (T-score ≥ -1), and the rate of bone loss is less than or equal to 1% per year. The analyses showed that for someone with a normal baseline BMD and a rate of bone loss of less than 1% per year, the change in BMD is not likely to exceed least significant change (even for a 1% precision) in less than 3 years after the baseline test, and is not likely to drop to a BMD level that requires initiation of treatment in less than 16 years after the baseline test. Seven published meta-analysis of randomized controlled trials (RCTs) and 2 recent RCTs on BMD monitoring during osteoporosis therapy showed that although higher increases in BMD were generally associated with reduced risk of fracture, the change in BMD only explained a small percentage of the fracture risk reduction.Studies showed that some people with small or no increase in BMD during treatment experienced significant fracture risk reduction, indicating that other factors such as improved bone microarchitecture might have contributed to fracture risk reduction.There is conflicting evidence relating to the role of BMD testing in improving patient compliance with osteoporosis therapy.Even though BMD may not be a perfect surrogate for reduction in fracture risk when monitoring responses to osteoporosis therapy, experts advised that it is still the only reliable test available for this purpose.A systematic review conducted by the Medical Advisory Secretariat showed that the magnitude of increases in BMD during osteoporosis drug therapy varied among medications. Although most of the studies yielded mean percentage increases in BMD from baseline that did not exceed the least significant change for a 2% precision after 1 year of treatment, there were some exceptions. A review of 3 published pooled analyses of observational studies and 12 prospective population-based observational studies showed that the presence of any prevalent fracture increases the relative risk for future fractures by approximately 2-fold or more. (ABSTRACT TRUNCATED)

  2. Single- versus dual-energy quantitative computed tomography for spinal densitometry in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Laan, R.F.J.M.; Erning, L.J.Th.O. van; Lemmens, J.A.M.; Putte, L.B.A. van de; Ruijs, S.H.J.; Riel, P.L.C.M. van

    1992-01-01

    Lumbar bone mineral density was measured by both single- and dual-energy quantitative computed tomography in 109 patients with rheumatoid arthritis. The results were corrected for the age-related increase in vertebral fat content by converting them to percentages of expected densities, using sex and energy-level specific regression equations obtained in a normal reference population. The percentages of expected density are approximately 10% lower in the single- than in the dual-energy mode, both in the patients with and without prednisone therapy. This difference is statistically highly significant, and is positively correlated with the duration of the disease and with the degree of radiological joint destruction. The data suggest that the vertebral fat content may be increased in patients with rheumatoid arthritis, as a consequence of disease-dependent mechanisms. (Author)

  3. Quantitative determination of anticonvulsant-induced bone demineralization by an improved x-ray densitometry technique

    Energy Technology Data Exchange (ETDEWEB)

    Wolschendorf, K.; Vanselow, K.; Schulz, H.; Moeller, W.D.

    1983-10-01

    Quantitative studies of the influence of anticonvulsant drugs on bone mineral content of 88 epileptics were performed by a microcomputer-aided densitometer system. The results showed that the mineral content decreases significantly with the duration of the therapy. This decrease was found to be approximately 1.2% per year for a Diphenylhydantoin (DPH) monotherapy and 1.8% per year and 2.0% per year for a DPH plus Phenobarbital and DPH plus Carbamazepin combination therapy.

  4. ANALISIS KUANTITATIF ISOFLAVON TEMPE SECARA CEPAT DAN SEDERHANA MENGGUNAKAN METODE KROMATOGRAFI LAPIS TIPIS- DENSITOMETRI

    Directory of Open Access Journals (Sweden)

    Agustina Setiawati

    2014-05-01

    Full Text Available Abstract: Rapid and simple quantitative analysis isoflavones tempe using densitometric TLC has been done. The mobile phase of the system was chloroform: methanol: ethylacetate (45: 5: 0.75. Thin layer chromatography was performed on aluminium TLC plates.Ascending distance of 1 μL sample was performanced 10 cm. Then the plate was scanned at 261 nm. A linear relationship obtained at 0.08 - 2 μg/spot with r= 0.9986. The LOD and LOQ of isoflavone were 0.014 μg/spot and 0.048 μg/spot. Genistein contained in tempe was 0.151± 0.005 % b/b. Keywords: tempe, isoflavon, TLC

  5. Alveolar bone healing process in spontaneously hypertensive rats (SHR). A radiographic densitometry study.

    Science.gov (United States)

    Manrique, Natalia; Pereira, Cassiano Costa Silva; Garcia, Lourdes Maria Gonzáles; Micaroni, Samuel; Carvalho, Antonio Augusto Ferreira de; Perri, Sílvia Helena Venturoli; Okamoto, Roberta; Sumida, Doris Hissako; Antoniali, Cristina

    2012-01-01

    Hypertension is one of the most important public health problems worldwide. If undiagnosed or untreated, this pathology represents a systemic risk factor and offers unfavorable conditions for dental treatments, especially those requiring bone healing. The purpose of this study was to demonstrate, by analysis of bone mineral density (BMD), that the alveolar bone healing process is altered in spontaneously hypertensive rats (SHRs). Wistar rats and SHRs were submitted to extraction of the upper right incisor and were euthanized 7, 14, 21, 28 and 42 days after surgery. Right maxillae were collected, radiographed and analyzed using Digora software. BMD was expressed as minimum (min), middle (med) and maximum (max) in the medium (MT) and apical (AT) thirds of the dental alveolus. The results were compared across days and groups. Wistar showed difference in med and max BMD in the MT between 7 and 28 and also between 14 and 28 days. The AT exhibited significant difference in med and min BMD between 7 and 28 days, as well as difference in min BMD between 28 and 42 days. SHRs showed lower med BMD in the MT at 28 days when compared to 21 and 42 days. Differences were observed across groups in med and min BMD at day 28 in the MT and AT; and in max BMD at 14, 21 and 42 days in the MT. These results suggest that the alveolar bone healing process is delayed in SHRs comparing with Wistar rats.

  6. Assessment of age and sex by means of DXA bone densitometry: application in forensic anthropology.

    Science.gov (United States)

    Castillo, Rafael Fernández; Ruiz, Maria del Carmen López

    2011-06-15

    Today we are witnessing a genuine revolution in diagnostic imaging techniques. Dual X-ray absorptiometry (DEXA) quantifies bone mineral density (BMD) and bone mineral content (BMC). This technique has rarely been used in Forensic Anthropology, although its practical application has been demonstrated by various authors. In this article, we look into the conduct of bone mineral density in the femoral neck, the trochanter, the intertrochanter, the proximal femur and Ward's triangle, in relation to anthropometric age and sex parameters. The research was carried out on 70 persons - 38 men and 32 women - and the results obtained show significant correlations between bone mineral density measurements and anthropometric values. The research demonstrates bone mineral density to be a useful technique for sex and age data in forensic anthropology, particularly in the measurements observed in the Ward's triangle area. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Assessment of bone in Ehlers Danlos syndrome by ultrasound and densitometry.

    Science.gov (United States)

    Dolan, A L; Arden, N K; Grahame, R; Spector, T D

    1998-10-01

    Ehlers Danlos syndrome (EDS) is an inherited disorder of connective tissue characterised by hyperextensible skin, joint laxity, and easy bruising. There are phenotypic similarities with osteogenesis imperfecta, but in EDS a tendency to fracture or altered bone mass has not previously been considered to be a cardinal feature. This case-control design study investigates whether 23 patients with EDS had differences in fracture rates, bone mass, and calcaneal ultrasound parameters compared with age and sex matched controls. 23 cases of EDS (mean (SD) age 38.5 (15.5)) were compared with 23 controls (mean age 37.8 (14.5)). A significant reduction in bone density measured by dual energy x ray absorptiometry was found at the neck of femur by 0.9 SD, p = 0.05, and lumbar spine by 0.74 SD, p = 0.02. At the calcaneum, broad band ultrasound attenuation and speed of sound were significantly reduced compared with controls by 0.95 SD (p = 0.004) and 0.49 SD (p = 0.004) for broad band ultrasound attenuation and speed of sound respectively. Broad band ultrasound attenuation and speed of sound remained significantly reduced after adjusting for bone mineral density (BMD). After adjusting for functional status (HAQ), age and sex, hypermobility was inversely correlated with broad band ultrasound attenuation and SOS, but not BMD at hip or spine. Previous fracture was 10 times more common in EDS (p exercise. This is one of the first clinical studies to suggest ultrasound can detect structural differences in bone, independent of dual energy x ray absorptiometry.

  8. Utility of radius bone densitometry for the treatment of osteoporosis with once-weekly teriparatide therapy

    Directory of Open Access Journals (Sweden)

    Harumi Nakayama

    2018-03-01

    Full Text Available Objectives: As clinics that treat patients with osteoporosis do not usually have central dual-energy X-ray absorptiometry (DXA, bone density is often measured with radial DXA. However, no long-term evidence exists for radius bone density outcomes following treatment with once-weekly teriparatide in actual medical treatment. Methods: We evaluated changes in bone density at 6-, 12-, and 18-month intervals using radial DXA in patients treated with once-weekly teriparatide for more than 6 months. Results: A significant increase in bone mineral density (BMD was observed at the 1/3 and 1/10 radius sites 12 months after the initiation of once-weekly teriparatide. We also observed that the rate of change in BMD was greater at the distal 1/10 radius than at the 1/3 radius. Conclusions: Considering these points, the effect of once-weekly teriparatide therapy can be observed at the radius. In clinics that do not have central DXA, but instead have radial DXA, these findings can help to evaluate the effect of once-weekly teriparatide treatment on osteoporosis. Keywords: Once-weekly teriparatide, Osteoporosis, Radius, Dual-energy X-ray absorptiometry

  9. Recovery of high purity proteins from polyacrylamide gels using ultraviolet scanning densitometry

    International Nuclear Information System (INIS)

    Bartolini, P.; Arkaten, R.; Ribela, M.T.C.P.

    1988-07-01

    We present here a technique for the purification of proteins carried out by a quantitative analytical method used in conjunction with a preparative gel electrophoresis. Both methods employ densitometric ultraviolet scanning of unstained protein bands, a procedure wich is particulary suitable for the purification and recovery of biologically active polypeptides. In short, the purified extracted protein, isolated in a segment cut out from a preparative gel, is recovered by a second (reversed) electrophoresis. We performed the extractions and recoveries of different amounts of two standard proteins (BSA and STI) and a polypeptide hormone (hGH). Our main interest, especially for the hormone is the complete protein recovery with retention of bio and immunoactivity and high purity. For the proteins tested, the mean recovery was of 93 + - 5% obtaining a mean purity of 95 + - 7%. We conclude that the proposed method should have interesting applications, particularly in the obtention of very pure hormones, as are needed for radioligand assays, for radiolabelling and specific antibody raising. We emphasize the simplicity and rapidity of the method (the entire preparative process: first electrophoresis, UV scanning and reversed electrophoresis can be performed in approximately six hours) and its efficiency in recovering pure proteins even on a milligram scale. We thank the support from the IAEA (4299/RB) and FINEP (43.86.0351.00) and CENE (Brazil). (author) [pt

  10. Use of Radiographic Densitometry to Predict the Bone Healing Index in Distraction Osteogenesis

    Directory of Open Access Journals (Sweden)

    A Saw

    2008-04-01

    Full Text Available Bone lengthening with distraction osteogenesis involves prolonged application of an external fixator frame. Qualitative and quantitative evaluation of callus has been described using various imaging modalities but there is no simple reliable and readily available method. This study aims to investigate the use of a densitometer to analyze plain radiographic images and correlate them with the rate of new bone formation as represented by the bone healing index. A total of 34 bone lengthening procedures in 29 patients were retrospectively reviewed. We used an X-Rite 301 densitometer to measure densities of new callus on plain radiographs taken at 4 and 8 weeks after surgery. Patients aged below 16y had significantly lower BHIs indicating faster bone healing and shorter duration of treatment. The ratio of radiographic densities between centre and edge of the new bone measured from plain radiographs taken at 8 weeks correlated positively with the eventual BHI of the patient. This method provides a simple and easy way to predict the rate of bone healing at an early stage of treatment and may also allow remedial action to be taken for those with poor progress in bone formation.

  11. Comparison between wire mesh sensor and gamma densitometry void measurements in two-phase flows

    Science.gov (United States)

    Sharaf, S.; Da Silva, M.; Hampel, U.; Zippe, C.; Beyer, M.; Azzopardi, B.

    2011-10-01

    Wire mesh sensors (WMS) are fast imaging instruments that are used for gas-liquid and liquid-liquid two-phase flow measurements and experimental investigations. Experimental tests were conducted at Helmholtz-Zentrum Dresden-Rossendorf to test both the capacitance and conductance WMS against a gamma densitometer (GD). A small gas-liquid test facility was utilized. This consisted of a vertical round pipe approximately 1 m in length, and 50 mm internal diameter. A 16 × 16 WMS was used with high spatial and temporal resolutions. Air-deionized water was the two-phase mixture. The gas superficial velocity was varied between 0.05 m s-1 and 1.4 m s-1 at two liquid velocities of 0.2 and 0.7 m s-1. The GD consisted of a collimated source and a collimated detector. The GD was placed on a moving platform close to the plane of wires of the sensor, in order to align it accurately using a counter mechanism, with each of the wires of the WMS, and the platform could scan the full section of the pipe. The WMS was operated as a conductivity WMS for a half-plane with eight wires and as a capacitance WMS for the other half. For the cross-sectional void (time and space averaged), along each wire, there was good agreement between WMS and the GD chordal void fraction near the centre of the pipe.

  12. Comparison between wire mesh sensor and gamma densitometry void measurements in two-phase flows

    International Nuclear Information System (INIS)

    Sharaf, S; Azzopardi, B; Da Silva, M; Hampel, U; Zippe, C; Beyer, M

    2011-01-01

    Wire mesh sensors (WMS) are fast imaging instruments that are used for gas–liquid and liquid–liquid two-phase flow measurements and experimental investigations. Experimental tests were conducted at Helmholtz-Zentrum Dresden-Rossendorf to test both the capacitance and conductance WMS against a gamma densitometer (GD). A small gas–liquid test facility was utilized. This consisted of a vertical round pipe approximately 1 m in length, and 50 mm internal diameter. A 16 × 16 WMS was used with high spatial and temporal resolutions. Air–deionized water was the two-phase mixture. The gas superficial velocity was varied between 0.05 m s −1 and 1.4 m s −1 at two liquid velocities of 0.2 and 0.7 m s −1 . The GD consisted of a collimated source and a collimated detector. The GD was placed on a moving platform close to the plane of wires of the sensor, in order to align it accurately using a counter mechanism, with each of the wires of the WMS, and the platform could scan the full section of the pipe. The WMS was operated as a conductivity WMS for a half-plane with eight wires and as a capacitance WMS for the other half. For the cross-sectional void (time and space averaged), along each wire, there was good agreement between WMS and the GD chordal void fraction near the centre of the pipe

  13. Use of Radiographic Densitometry to Predict the Bone Healing Index in Distraction Osteogenesis

    OpenAIRE

    A Saw; S Manimaran; S Faizal; AM Bulgiba

    2008-01-01

    Bone lengthening with distraction osteogenesis involves prolonged application of an external fixator frame. Qualitative and quantitative evaluation of callus has been described using various imaging modalities but there is no simple reliable and readily available method. This study aims to investigate the use of a densitometer to analyze plain radiographic images and correlate them with the rate of new bone formation as represented by the bone healing index. A total of 34 bone lengthening pro...

  14. Bone densitometry by gamma ray attenuation measurement. Development of an apparatus for use on medullary casualties

    International Nuclear Information System (INIS)

    Berard, E.J.-J.

    1975-01-01

    We proposed to follow changes in the bone mineral content of medullary damage cases by measuring the attenuation of a monoenergetic gamma ray according to the Cameron and Sorenson technique. Apart from their high cost, existing instruments are not designed for this bedside observation of patients. Our aim was therefore to design and develop an easily portable, inexpensive apparatus. The γ radiation is supplied by a sealed 125 I source fitted with a narrow collimator. The battery-operated scintillation detector is that used to detect post-operative phlebites after injection of radio-fibrinogen. The source-detector unit can move to allow a transverse bone mineral content measurement. Data from the detector are processed electronically and the results given: - either graphically on a tracing board which gives an area proportional to the bone mineral content, - or numerically by means of an integrator computing this area and supplying the linear bone density directly. Experiments carried out in vivo showed the apparatus to be sensitive and the measurements reproducible, the results obtained being comparable with those of other authors. Using pieces of embalmed bone moreover an excellent correlation was observed between the bone mineral content obtained after incineration and the results displayed by our apparatus, which can therefore be calibrated [fr

  15. Screening and determination of sibutramine in adulterated herbal slimming supplements by HPTLC-UV densitometry.

    Science.gov (United States)

    Mathon, Caroline; Ankli, Anita; Reich, Eike; Bieri, Stefan; Christen, Philippe

    2014-01-01

    The adulteration of herbal supplements is of growing importance, especially when they contain undeclared compounds like sibutramine that are unsafe drugs. Sibutramine was withdrawn from US and European markets in 2010. In this study, an HPTLC-UV densitometric method was developed for the quantification of sibutramine in herbal diet foods. Sample extracts were directly applied onto HPTLC silica gel plates and separated with a mobile phase made of a toluene-methanol mixture. Sibutramine was quantified at 225 nm and its unequivocal identification was confirmed by MS using a TLC-MS interface. During two surveys, 52 weight loss supplements obtained via the Internet were screened. Half of those were adulterated with sibutramine at amounts reaching up to 35 mg per capsule. The results of this validated HPTLC method were compared with those obtained by HPLC-UV and HPLC-MS/MS. The results were not significantly different with the three methods.

  16. In-vivo precision - a crucial factor in bone densitometry. First results from the clinical practice

    International Nuclear Information System (INIS)

    Slavchev, A.

    2008-01-01

    The good densitometric practice should include assessment of the measurement accuracy and precision as a warranty for the timely recognition and assessment of the disease and particularly important for the monitoring and assessment of its development as well as for the choice of the adequate therapy. First results from a large-scale study of the performance of DXA densitometers under operation throughout the country prove that one of the main characteristics - precision has prevalent importance for the clinical practice than the other one - accuracy, namely in diagnostics and therapy particularly the long term monitoring of the patients. The quality control especially in its part of radiation protection measurements exhibits high specificity concerning both operator and patient. The procedure of determining of the in-vivo precision error and the least significant change, respectively, and the screening as well are interconnected with a higher degree of radiation exposure for the operator staff. The in-vivo precision (errors) obtained from the clinical practice in the most of the osteoporosis centres is inferior to the values recommended by the ISCD and by this represent a warranty for a high degree of objectivity and reducing the subjective and stochastic factors in diagnostics and following-up of osteoporosis. (author)

  17. Bone densitometry in normal women of reproductive age: Correlation with reference values and anthropometric variables

    International Nuclear Information System (INIS)

    Lobo, G.; Palma, T.; Ladron de Guevara, D.

    2002-01-01

    Bone mass density measurements using X rays is considered to be the non-invasive reference method to measure bone mineral density. Even though the technology has reached a high level of development, precision and reproducibility must be optimised to assure that the observed variations are due solely to the variations in bone mineral content, and not to other associated variables, either technical or biological. The main factors affecting bone density measurements are those that depend on the technique used and those which depend on characteristics of the individuals. The variability associated with the technique can be minimised by an adequate standardisation and quality control. Among those characteristics of the individuals, which have been mentioned as a source of variability, the most important are related to the anthropomorphic characteristics such as size and depth of osseous structures, and thickness and characteristics of soft tissues. These factors may be especially important because the interpretation of bone mass density measurements depends on values obtained for reference normal populations, which are incorporated into the bone mass densitometers as reference value databases. Usually the anthropomorphic characteristics of this reference population are unknown and can be different from those of the local population, independently of genetic or ethnic factors. This situation leads to error both in the definition of basic concepts such as osteopenia and osteoporosis, and in the interpretation of individual results for population studies. The purpose of this study is to correlate bone density measurements of normal Chilean women with reference value databases and with parameters, which depend on body size

  18. Lens densitometry after corneal cross-linking in patients with keratoconus using a Scheimpflug camera

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafii

    2015-01-01

    Conclusion: In this short term study with six months' follow-up, we observed no significant impact on lens density following exposure of the crystalline lens to ultraviolet A and riboflavin free radicals in the CXL procedure.

  19. Exploring the role of CT densitometry: a randomised study of augmentation therapy in alpha1-antitrypsin deficiency

    DEFF Research Database (Denmark)

    Dirksen, A; Piitulainen, E; Parr, D G

    2009-01-01

    for the assessment of the therapeutic effect of augmentation therapy in subjects with alpha(1)-antitrypsin (alpha(1)-AT) deficiency. In total, 77 subjects (protease inhibitor type Z) were randomised to weekly infusions of 60 mg x kg(-1) human alpha(1)-AT (Prolastin) or placebo for 2-2.5 yrs. The primary end...... was unaltered by treatment, but a reduction in exacerbation severity was observed. In patients with alpha(1)-AT deficiency, CT is a more sensitive outcome measure of emphysema-modifying therapy than physiology and health status, and demonstrates a trend of treatment benefit from alpha(1)-AT augmentation....

  20. Precision of bone densitometry measurements: When is change true change and does it vary across bone density values?

    International Nuclear Information System (INIS)

    Wong, J.C.H.; Griffiths, M.R.

    2003-01-01

    The precision error of the bone densitometer is used to interpret significant change in bone mineral density (BMD) in serial studies. The precision error can be expressed as standard deviation (SD) or coefficient of variation (CV). The aims of this study are to determine the precision error over a range of BMD values and to demonstrate the application of the precision error in clinical practice. A bone phantom was used consisting of a perspex block with eight compartments containing varying amounts of hydroxyapatite powder to simulate a range of bone densities. The block was scanned 21 times and manual regions placed over each compartment to measure the BMD in each compartment. There were no significant differences in the variances or SD for all eight compartments, that is, over the range of BMD normally encountered in clinical practice. However, the calculated CV show a progressive fall in values as the BMD rises. Therefore, the SD should be used to calculate significant BMD change. In a practise with quality control procedures in place to detect calibration drift and with appropriately trained personnel, a change of approximately 0.05 g/cm 2 is generally regarded as being a significant change at a 95% confidence level. Copyright (2003) Blackwell Science Pty Ltd

  1. Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

    International Nuclear Information System (INIS)

    Peña, Jaime A.; Damm, Timo; Bastgen, Jan; Barkmann, Reinhard; Glüer, Claus C.; Thomsen, Felix; Campbell, Graeme M.

    2016-01-01

    Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm 3 corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

  2. Distribution and densitometry mapping of L1-CAM Immunoreactivity in the adult mouse brain – light microscopic observation

    Directory of Open Access Journals (Sweden)

    Yamasaki Hironobu

    2003-04-01

    Full Text Available Abstract Background The importance of L1 expression in the matured brain is suggested by physiological and behavioral studies showing that L1 is related to hippocampal plasticity and fear conditioning. The distribution of L1 in mouse brain might provide a basis for understanding its role in the brain. Results We examined the overall distribution of L1 in the adult mouse brain by immunohistochemistry using two polyclonal antibodies against different epitopes for L1. Immunoreactive L1 was widely but unevenly distributed from the olfactory bulb to the upper cervical cord. The accumulation of immunoreactive L1 was greatest in a non-neuronal element of the major fibre bundles, i.e. the lateral olfactory tract, olfactory and temporal limb of the anterior commissure, corpus callosum, stria terminalis, globus pallidus, fornix, mammillothalamic tract, solitary tract, and spinal tract of the trigeminal nerve. High to highest levels of non-neuronal and neuronal L1 were found in the grey matter; i.e. the piriform and entorhinal cortices, hypothalamus, reticular part of the substantia nigra, periaqueductal grey, trigeminal spinal nucleus etc. High to moderate density of neuronal L1 was found in the olfactory bulb, layer V of the cerebral cortex, amygdala, pontine grey, superior colliculi, cerebellar cortex, solitary tract nucleus etc. Only low to lowest levels of neuronal L1 were found in the hippocampus, grey matter in the caudate-putamen, thalamus, cerebellar nuclei etc. Conclusion L1 is widely and unevenly distributed in the matured mouse brain, where immunoreactivity was present not only in neuronal elements; axons, synapses and cell soma, but also in non-neuronal elements.

  3. Identification and determination of oxytetracycline, tiamulin, lincomycin, and spectinomycin in veterinary preparations by thin-layer chromatography/densitometry.

    Science.gov (United States)

    Krzek, J; Kwiecień, A; Starek, M; Kierszniewska, A; Rzeszutko, W

    2000-01-01

    A thin-layer chromatographic/densitometric method was developed for the identification and quantitation of oxytetracycline, tiamulin, lincomycin, and spectinomycin in veterinary preparations. Silica gel-coated thin layer chromatography plates and 2 mobile phases were used to separate these constituents. The appropriate compositions of the suitable mobile phases were established: 10% citric acid solution-n-hexane-ethanol (80 + 1 + 1, v/v) and n-butanol-ethanol-chloroform-25% ammonia (4 + 5 + 2 + 5, v/v). Along with Rf values and spot colors, direct UV and visual densitometric measurements were used for identification. Similar measuring ranges were used for quantitative analysis to obtain repeatable and reliable results for the preparations examined. The results of the quantitative analysis are characterized by a small confidence interval and are close to the declared contents of active constituents: oxytetracycline 30.01 +/- 0.38 g at lambda = 350 nm and 30.24 +/- 0.86 g at lambda = 430 nm; tiamulin, 10.19 +/- 0.86 g at lambda = 450 nm; lincomycin, 2.27 +/- 0.08 g at lambda = 278 nm; and spectinomycin, 2.18 +/- 0.07 g at lambda = 421 nm. The recoveries for all antibiotics ranged from 100.01 to 102.54%.

  4. A quantitative determination of anticonvulsant-induced bone demineralization by an improved x-ray densitometry technique

    International Nuclear Information System (INIS)

    Wolschendorf, K.; Vanselow, K.; Schulz, H.; Moeller, W.D.

    1983-01-01

    Quantitative studies of the influence of anticonvulsant drugs on bone mineral content of 88 epileptics were performed by a microcomputer-aided densitometer system. The results showed that the mineral content decreases significantly with the duration of the therapy. This decrease was found to be approximately 1.2% per year for a Diphenylhydantoin (DPH) monotherapy and 1.8% per year and 2.0% per year for a DPH plus Phenobarbital and DPH plus Carbamazepin combination therapy. (orig.)

  5. Bone densitometry as an indicator of percentage tibia ash in broiler chicks fed varying dietary calcium and phosphorus levels.

    Science.gov (United States)

    Onyango, E M; Hester, P Y; Stroshine, R; Adeola, O

    2003-11-01

    The relative sensitivity of tibia bone mineral content (BMC) and density (BMD), percentage ash (ash), and shear force as indicators for dietary Ca and P was compared in 3-wk-old broiler chicks. One hundred eight 7-d-old chicks were grouped by weight into 6 blocks of 3 cages each with 6 birds per cage. Three corn-soybean meal-based diets were randomly assigned to cages within each block. The diets were low P, medium P, and adequate P and were formulated to contain 4.0, 5.1, and 7.8 g of total P/kg feed, respectively; and 5.1, 6.7, and 10.0 g of Ca/kg feed, respectively. The chicks were fed the experimental diets for 14 d. On d 22, chicks were killed, and tibiae were removed from 3 birds/cage. Weight gain, feed intake, feed efficiency, BMC, BMD, shear force, and ash were determined. The BMC and BMD were determined using dual energy x-ray absorptiometry. Correlations among the various bone status variables and dietary Ca and P were determined. Growth performance criteria and ash increased linearly, and BMC and BMD increased linearly and quadratically as dietary concentrations of Ca and P increased. The correlation coefficient between dietary Ca and BMC, BMD, shear force, or ash was 0.89, 0.91, 0.50, or 0.89, respectively; and between dietary P and BMC, BMD, shear force, or ash was 0.88, 0.91, 0.48, or 0.89, respectively. The correlation coefficient between ash and BMC, BMD, or shear force was 0.92, 0.93, or 0.67, respectively. The correlation coefficients for linear regression between shear force and BMC or BMD was 0.56. The regression model for predicting percentage ash using BMD was as follows: percentage ash = 24 + (240 x BMD) with an r2 of 86%. It is concluded that in broiler chicks, tibia ash, BMC, and BMD may be more sensitive than shear force as indicators of dietary Ca and P concentrations and that BMD as measured by dual energy x-ray absorptiometry may be used to predict percentage of tibia ash.

  6. Quantification of Sunscreen Ethylhexyl Triazone in Topical Skin-Care Products by Normal-Phase TLC/Densitometry

    Directory of Open Access Journals (Sweden)

    Anna W. Sobanska

    2012-01-01

    Full Text Available Ethylhexyl triazone (ET was separated from other sunscreens such as avobenzone, octocrylene, octyl methoxycinnamate, and diethylamino hydroxybenzoyl hexyl benzoate and from parabens by normal-phase HPTLC on silica gel 60 as stationary phase. Two mobile phases were particularly effective: (A cyclohexane-diethyl ether 1 : 1 (v/v and (B cyclohexane-diethyl ether-acetone 15 : 1 : 2 (v/v/v since apart from ET analysis they facilitated separation and quantification of other sunscreens present in the formulations. Densitometric scanning was performed at 300 nm. Calibration curves for ET were nonlinear (second-degree polynomials, with R > 0.998. For both mobile phases limits of detection (LOD were 0.03 and limits of quantification (LOQ 0.1 μg spot−1. Both methods were validated.

  7. Quantification of sunscreen ethylhexyl triazone in topical skin-care products by normal-phase TLC/densitometry.

    Science.gov (United States)

    Sobanska, Anna W; Pyzowski, Jaroslaw

    2012-01-01

    Ethylhexyl triazone (ET) was separated from other sunscreens such as avobenzone, octocrylene, octyl methoxycinnamate, and diethylamino hydroxybenzoyl hexyl benzoate and from parabens by normal-phase HPTLC on silica gel 60 as stationary phase. Two mobile phases were particularly effective: (A) cyclohexane-diethyl ether 1 : 1 (v/v) and (B) cyclohexane-diethyl ether-acetone 15 : 1 : 2 (v/v/v) since apart from ET analysis they facilitated separation and quantification of other sunscreens present in the formulations. Densitometric scanning was performed at 300 nm. Calibration curves for ET were nonlinear (second-degree polynomials), with R > 0.998. For both mobile phases limits of detection (LOD) were 0.03 and limits of quantification (LOQ) 0.1 μg spot(-1). Both methods were validated.

  8. Quantification of Sunscreen Ethylhexyl Triazone in Topical Skin-Care Products by Normal-Phase TLC/Densitometry

    OpenAIRE

    Sobanska, Anna W.; Pyzowski, Jaroslaw

    2012-01-01

    Ethylhexyl triazone (ET) was separated from other sunscreens such as avobenzone, octocrylene, octyl methoxycinnamate, and diethylamino hydroxybenzoyl hexyl benzoate and from parabens by normal-phase HPTLC on silica gel 60 as stationary phase. Two mobile phases were particularly effective: (A) cyclohexane-diethyl ether 1 : 1 (v/v) and (B) cyclohexane-diethyl ether-acetone 15 : 1 : 2 (v/v/v) since apart from ET analysis they facilitated separation and quantification of other sunscreens present ...

  9. Bone densitometry in healthy cats by quantitative computed tomography; Densitometria ossea em gatos higidos por tomografia computadorizada quantitativa

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, D.C. [Universidade Federal do Parana - Curitiba, PR (Brazil); Costa, L.A.V.S.; Teixeira, M.W.; Costa, F.S. [Universidade Federal Rural de Pernambuco - Recife, PE (Brazil); Cardoso, M.J.L. [Universidade Estadual do Norte do Parana - Campus Luiz Meneghel - Bandeirantes, PR (Brazil)

    2012-06-15

    The radiodensity of the trabecular bone of the lumbar vertebrae in 16 healthy adult cats was studied using quantitative computed tomography (QCT). The average radiodensity of the trabecular bone of the second lumbar vertebra was 436.1 +- 42.1 Hounsfield units. However, there was a nonhomogeneous radiodensity distribution of the vertebral body. (author)

  10. Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Peña, Jaime A.; Damm, Timo; Bastgen, Jan; Barkmann, Reinhard; Glüer, Claus C., E-mail: glueer@rad.uni-kiel.de [Sektion Biomedizinische Bildgebung, Klinik für Radiologie und Neuroradiologie, Christian-Albrechts-Universität zu Kiel, Campus Kiel, Kiel 24118 (Germany); Thomsen, Felix [Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad Nacional del Sur, Bahía Blanca 8000 (Argentina); Campbell, Graeme M. [Sektion Biomedizinische Bildgebung, Klinik für Radiologie und Neuroradiologie, Christian-Albrechts-Universität zu Kiel, Campus Kiel, Kiel 24118, Germany and Institut für Biomechanik, Technische Universität Hamburg-Harburg (TUHH), Hamburg 21073 (Germany)

    2016-07-15

    Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

  11. RELATIONSHIPS BETWEEN ANATOMICAL FEATURES AND INTRA-RING WOOD DENSITY PROFILES IN Gmelina arborea APPLYING X-RAY DENSITOMETRY

    Directory of Open Access Journals (Sweden)

    Mario Tomazelo-Filho

    2007-12-01

    Full Text Available Four annual tree-rings (2 of juvenile wood and 2 of mature wood were sampled from fast-growth plantations ofGmelina arborea in two climatic conditions (dry and wet tropical in Costa Rica. Each annual tree-ring was divided in equal parts ina radial direction. For each part, X-ray density as well as vessel percentage, length and width fiber, cell wall thickness and lumendiameter were measured. Wood density and profile patterns of cell dimension demonstrated inconsistency between juvenile andmature wood and climatic conditions. The Pearson correlation matrix showed that intra-ring wood density was positively correlatedwith the cell wall thickness and negatively correlated with vessel percentage, fiber length, lumen diameter and width. The forwardstepwise regressions determined that: (i intra-ring wood density variation could be predicted from 76 to 96% for anatomicalvariation; (ii cell wall thickness was the most important anatomical feature to produce intra-ring wood density variation and (iii thevessel percentage, fiber length, lumen diameter and width were the second most statically significant characteristics to intra-ring wooddensity, however, with low participation of the determination coefficient of stepwise regressions.

  12. Analysis of the static pressure volume curve of the lung in experimentally induced pulmonary damage by CT-densitometry

    International Nuclear Information System (INIS)

    David, M.; Karmrodt, J.; Herwelling, A.; Bletz, C.; David, S.; Heussel, C.P.; Markstaller, K.

    2005-01-01

    Purpose: To study quantitative changes of lung density distributions when recording in- and expiratory static pressure-volume curves by single slice computed tomography (CT). Materials and Methods: Static in- and expiratory pressure volume curves (0 to 1000 ml, increments of 100 ml) were obtained in random order in 10 pigs after induction of lung damage by saline lavage. Simultaneously, CT acquisitions (slice thickness 1 mm, temporal increment 2 s) were performed in a single slice (3 cm below the carina). In each CT image lung segmentation and planimetry of defined density ranges were achieved. The lung density ranges were defined as: hyperinflated (-1024 to -910 HU), normal aerated (-910 to -600 HU), poorly aerated (-600 to -300 HU), and non aerated (-300 to 200 HU) lung. Fractional areas of defined density ranges in percentage of total lung area were compared to recorded volume increments and airway pressures (atmospheric pressure, lower inflection point (LIP), LIP*0.5, LIP*1.5, peak airway pressure) of in- and expiratory pressure-volume curves. Results: Quantitative analysis of defined density ranges showed no differences between in- and expiratory pressure-volume curves. The amount of poorly aerated lung decreased and normal aerated lung increased constantly when airway pressure and volume were increased during inspiratory pressure-volume curves and vice versa during expiratory pressure-volume loops. Conclusion: Recruitment and derecruitment of lung atelectasis during registration of static in- and expiratory pressure-volume loops occurred constantly, but not in a stepwise manner. CT was shown to be an appropriate method to analyse these recruitment process. (orig.)

  13. Quantitative assessment of radiation-induced lung changes by computerized optical densitometry of routine chest x-rays

    International Nuclear Information System (INIS)

    Bentzen, Soeren M.; Skoczylas, Jerzy Z.; Overgaard, Marie; Overgaard, Jens; Nielsen, Ole G.; Madsen, Erik Hjoellund

    1996-01-01

    Purpose: To develop a quantitative assay of radiological lung changes after postmastectomy radiotherapy applicable for analysis of routine chest x-rays. Methods and Materials: The assay relies on measurement of the optical density of chest x-rays by means of a standard personal computer-controlled film densitometer used for scanning dosimetry films. Density profiles were recorded at 1 mm steps along two reference lines in each lung. The crossing between the clavicula and the first rib in the x-ray projection was used as an easily identifiable anatomical landmark and was used to establish two parallel cranio-caudal reference lines separated by 20 mm. The starting point for recording optical densities was 5 mm below a line perpendicular to the reference lines and tangent to the top of the lung. Data were stored in a computer file for subsequent processing. The optical film densities in the apex of the lungs were converted into equivalent absorber thickness (EAT). To minimize the dependency on technical factors, the unirradiated lung was used as a control. Lung density changes were quantified by the relative change in EAT (REAT), which was evaluated as the difference between the summed EATs along the reference lines in the two lungs, corrected for any pretreatment difference in lung density, and taken as a percentage of the pretreatment EAT value of the lung. Results: Four different tests were carried out to investigate the reproducibility and validity of the proposed assay. (a) An anthropomorphic phantom was used to test the relationship between REAT and the layer of plastic absorber placed in front of one lung. A linear relationship was found with a correlation coefficient of 0.9993. (b) A series of 10 repeat measurements of the same arbitrarily chosen x-ray showed a mean REAT value of 9.8%, with a standard deviation of 0.21%. (c) Forty-three chest x-rays exposed on the same day were available from the clinical series. These were treated as double determinations of REAT values, and the standard deviation was estimated at 1.35%. (d) REAT values estimated with this assay were significantly correlated with the scores of two experienced specialists, an oncologist and a radiologist (Spearman's rank correlation coefficient being 0.065, p -8 ). Conclusion: This assay quantifies radiation-induced lung injury from routine chest x-rays. Thus, it is possible to take advantage of the very large retrospective materials available in most oncological institutions. The assay has been validated in a phantom experiment and shown to be reproducible. Furthermore, it is technically easy to perform

  14. Uni-dimensional double development HPTLC-densitometry method for simultaneous analysis of mangiferin and lupeol content in mango (Mangifera indica) pulp and peel during storage.

    Science.gov (United States)

    Jyotshna; Srivastava, Pooja; Killadi, Bharti; Shanker, Karuna

    2015-06-01

    Mango (Mangifera indica) fruit is one of the important commercial fruit crops of India. Similar to other tropical fruits it is also highly perishable in nature. During storage/ripening, changes in its physico-chemical quality parameters viz. firmness, titrable acidity, total soluble solid content (TSSC), carotenoids content, and other biochemicals are inevitable. A uni-dimensional double-development high-performance thin-layer chromatography (UDDD-HPTLC) method was developed for the real-time monitoring of mangiferin and lupeol in mango pulp and peel during storage. The quantitative determination of both compounds of different classes was achieved by densitometric HPTLC method. Silica gel 60F254 HPTLC plates and two solvent systems viz. toluene/EtOAC/MeOH and EtOAC/MeOH, respectively were used for optimum separation and selective evaluation. Densitometric quantitation of mangiferin was performed at 390nm, while lupeol at 610nm after post chromatographic derivatization. Validated method was used to real-time monitoring of mangiferin and lupeol content during storage in four Indian cultivars, e.g. Bombay green (Bgreen), Dashehari, Langra, and Chausa. Significant correlations (pacidity and TSSC with mangiferin and lupeol in pulp and peel during storage were also observed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Advanced imaging of the musculoskeletal system: Standard, three-dimensional, and contrast-enhanced CT and MR imaging, and quantitative bone densitometry

    International Nuclear Information System (INIS)

    Resnick, D.; Sartoris, D.J.

    1987-01-01

    This course reviews the application of advanced imaging techniques to a broad spectrum of musculoskeletal disorders. The indications for and utility of standard CT in both the axial and the appendicular skeleton is explored. The combined use of CT with air and contrast arthrography at sites including the hip, knee, and shoulder is discussed. A summary of the proved and potential applications of MR imaging in osseous, articular, bone marrow, and soft-tissue disorders is provided. The utility of intraarticular contrast agents in enhancing the diagnostic capabilities of MR imaging for disorders of hyaline cartilage and and fibrocartilage is demonstrated. The advantages of multiplanar reformation and three-dimensional image reconstruction of cross-sectional imaging data are described in conjunction with the fundamental technological principles of these strategies. Accepted methods as well as investigative techniques for the diagnosis and follow-up of metabolic bone disease are contrasted with regard to relative indications, advantages, and limitations

  16. Dosimetric implications of shifts in linear accelerator electron beam energy detected in routine constancy checks: a scanning film densitometry detection method

    International Nuclear Information System (INIS)

    Cross, P.; Wang, Y.

    1993-01-01

    The effects of change in electron beam energy are primarily manifest by changes in the range parameters of the depth ionisation/dose curve. Even for a change of up to 10% in the mean energy at the surface, E O , the dose to the depth of maximum on the central axis changes by less than 1%. Using as a limit of acceptability that the change in the therapeutic range (R 85 ) should not be more than ±1.5 mm, the precision required by beam energy checking is that a change of 0.4 MeV in E O should be detectable for all electron beams provided by the accelerator. To satisfy this criterion a routine method is proposed that uses therapy verification film exposed to the electron beam under a perspex wedge. The automatically processed film is then scanned with the densitometer of a beam data acquisition system (BDAS). The optical density versus distance plot is analysed using the BDAS computer that converts it to a quasi-depth dose curve and then calculates E O and E p,0 from the range parameters. The results for electron beams from console energies of 5 to 14 MeV show that the test criterion is within the capability of the method, and that the method is very practical for routine use in a quality assurance program. 9 refs., 5 tab., 2 figs

  17. Evaluation of femur of orchiectomized Guinea pigs by bone densitometry using dual-energy X-ray absorptiometry (DXA) and mechanical testing

    Energy Technology Data Exchange (ETDEWEB)

    Estanislau, Cristiane de Abreu; Rahal, Sheila Canavese; Araujo, Fabio Andre Pinheiro de, E-mail: crisestanislau@hotmail.co, E-mail: sheilacr@fmvz.unesp.b, E-mail: fabioandre@fmvz.unesp.b [Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina, Veterinaria e Zootecnia. Dept. de Cirurgia e Anestesiologia Veterinaria; Sergio Swain Muller, E-mail: diretoria@fmb.unesp.b [Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina, Veterinaria e Zootecnia. Dept. de Cirurgia e Ortopedia; Louzada, Mario Jefferson Quirino, E-mail: louzada@fmva.unesp.b [Universidade Estadual Paulista (UNESP), Aracatuba, SP (Brazil). Faculdade de Medicina Veterinaria; Estanislau, Caroline de Abreu, E-mail: caestanis@hotmail.co

    2010-03-15

    The aim of this study was to evaluate the effects of castration on bones in the male guinea pigs and to observe whether mechanical testing correlates with dual-energy X-ray absorptiometry (DXA). Twelve male guinea pigs (Cavia porcellus), aged 21-27 days, and with average initial weight of 279 grams were used. The animals were equally allocated to two groups: GI - orchiectomized animals and GII - intact control animals. They underwent euthanasia at seven months following surgery. DXA measurement was performed at the mid third of the right femoral diaphysis in the cortical region and at the left femoral neck in order to verify its correlation with results of mechanical testing. Three-point bending test of right femur and axial compression test of left femur were performed. Bone mineral density of GI was significantly lower only at femoral neck. No differences were observed in the maximum load values between GI and GII for both bending and axial compression tests. The bending test revealed lower bone stiffness in GI compared to GII, but in the axial compression test no differences between groups were observed. Only left femur showed positive correlation coefficient between maximum load and bone mineral density according to Pearson's correlation coefficient. The results suggest that hormonal deprivation in guinea pigs induces reduction of bone mineral density, especially in the femoral neck area and reduction of bone stiffness in the mid-femoral diaphysis. (author)

  18. Prospective analysis of a first MTP total joint replacement. Evaluation by bone mineral densitometry, pedobarography, and visual analogue score for pain

    DEFF Research Database (Denmark)

    Wetke, Eva; Zerahn, Bo; Kofoed, Hakon

    2012-01-01

    We hypothesized that a total replacement of the first metatarsophalangeal joint (MTP-1) would alter the walking pattern with medialisation of the ground reaction force (GRF) of the foot and subsequently cause an increase in bone mineral density (BMD) in the medial metatarsal bones and a decline o...

  19. Femur morphometry, densitometry, geometry and mechanical properties in young pigs fed a diet free of inorganic phosphorus and supplemented with phytase.

    Science.gov (United States)

    Skiba, Grzegorz; Sobol, Monika; Raj, Stanisława

    2017-02-01

    The study investigated in piglets the effect of replacing dietary inorganic P by addition of microbial phytase and its impact on performance, nutrient digestibility and on the geometrical characteristics and mineralisation of the femur. Sixteen pigs on day 58 of age were divided into two groups and fed either a diet free of additional inorganic phosphorus (P) and supplemented with phytase (Diet LP, 4.23 g total P/kg diet) or a diet with a mineral source of P and not supplemented with phytase (Diet SP, 5.38 g total P/kg diet). Performance data and the apparent total tract digestibility of nutrients were estimated between days 58 and 114, and 72 and 86 of age, respectively. On day 114 of age, the pigs were slaughtered, the femur was dissected and the mineral content and mineral density, maximum strength and maximum elastic strength, cortical wall thickness, cross-sectional area and cortical index were analysed. The growth performance and digestibility of nutrient fractions (with exception of P) did not differ between treatment groups. The P-digestibility was significantly higher in Group LP. The femur of pigs in Group LP had significantly greater cortical wall thickness, cortical index, bone mineral content, bone mineral density, maximum strength and maximum elastic strength than Group SP. Femur maximum strength and maximum elastic strength were correlated with cortical wall thickness and cortical index. Resulting from the different supply of digestible P, the femur geometrical, densitometric and mechanical properties of Group LP were better than those of Group SP. The mechanical properties of the femur of pigs depended more on its geometrical characteristics than on the degree of its mineralisation.

  20. The impact of slice-reduced computed tomography on histogram-based densitometry assessment of lung fibrosis in patients with systemic sclerosis.

    Science.gov (United States)

    Nguyen-Kim, Thi Dan Linh; Maurer, Britta; Suliman, Yossra A; Morsbach, Fabian; Distler, Oliver; Frauenfelder, Thomas

    2018-04-01

    To evaluate usability of slice-reduced sequential computed tomography (CT) compared to standard high-resolution CT (HRCT) in patients with systemic sclerosis (SSc) for qualitative and quantitative assessment of interstitial lung disease (ILD) with respect to (I) detection of lung parenchymal abnormalities, (II) qualitative and semiquantitative visual assessment, (III) quantification of ILD by histograms and (IV) accuracy for the 20%-cut off discrimination. From standard chest HRCT of 60 SSc patients sequential 9-slice-computed tomography (reduced HRCT) was retrospectively reconstructed. ILD was assessed by visual scoring and quantitative histogram parameters. Results from standard and reduced HRCT were compared using non-parametric tests and analysed by univariate linear regression analyses. With respect to the detection of parenchymal abnormalities, only the detection of intrapulmonary bronchiectasis was significantly lower in reduced HRCT compared to standard HRCT (P=0.039). No differences were found comparing visual scores for fibrosis severity and extension from standard and reduced HRCT (P=0.051-0.073). All scores correlated significantly (Phistogram parameters derived from both, standard and reduced HRCT. Significant higher values of kurtosis and skewness for reduced HRCT were found (both Phistogram parameters from reduced HRCT showed significant discrimination at cut-off 20% fibrosis (sensitivity 88% kurtosis and skewness; specificity 81% kurtosis and 86% skewness; cut-off kurtosis ≤26, cut-off skewness ≤4; both Phistogram parameters derived from the approach of reduced HRCT could discriminate at a threshold of 20% lung fibrosis with high sensitivity and specificity. Hence it might be used to detect early disease progression of lung fibrosis in context of monitoring and treatment of SSc patients.

  1. Hptlc-densitometry mass spectrometric utilization in the chemical finger printing of herbal drugs-a case study on commiphora mukul (abstract)

    International Nuclear Information System (INIS)

    Musharaf, S.G.; Iqbal, N.; Gulzar, U.; Ali, A.; Choudhary, M.I.; Rahman, A.

    2011-01-01

    In Asia, particularly in the Indo-Pak sub-continent, plants have been used as sources of indigenous drugs for thousands of years. However, at the global level the traditional herbal medicines couldn't achieve significance in medical and scientific communities due to the lack of quantitative standardization and consistency. The quantitative analysis of medical plants by using TLC and HPTLC methods is increasingly popular as manufacturers, researchers, and drug regulatory authorities are recognizing their versatility and cost effectiveness. It has been demonstrated that these techniques can analyze even a mixture of 15 plants in a single analytical run. We have recently developed a HPTLC-densitometric method based on ICH (International Conference on Harmonization) recommendations for the analysis of hypolipidemic agents, E- and Z-guggulsterones and capable to separate both isomers from their conger, 17, (20)-dihydroguggulsterone (non-hypolipidemic agent) and therefore quantify the biomarker compounds precisely and equally applicable for the varieties of guggulsterone samples including resins, guggulipid and marketed formulations, for the first time. E- and Z-guggulsterones are the constituents of guggul or guggulu (Sanskrit), sticky gum resin obtained from the Mukul myrrh tree (Commiphora mukul), widely used in the traditional medicines, particularly in Ayurveda for the treatment of gout, arthritis, rheumatism, obesity and inflammation. Pharmacological studies showed that guggul lipid (45% ethyl acetate extract of guggul) lowers the blood lipids in patients and possessed clinically proved hypolipidemic activity. Moreover, Guggul helps to reduce high cholesterol, because it lowers harmful low density lipoproteins (LDL-proteins) while elevating the beneficial high density lipoproteins. It is well documented that the E- and Z-isomers of guggulsterones are the biomarker compounds, responsible the hypolipidemic activity. (author)

  2. Physicochemical data on aqueous polymeric systems of methyl cellulose and lambda- and kappa-carrageenan: SAXS, rheological, densitometry, and sound velocity measurements

    Directory of Open Access Journals (Sweden)

    Jure Cerar

    2017-12-01

    Full Text Available General as well as more specific physicochemical data obtained by studying the structure and various dynamical properties of aqueous polymer systems of methyl cellulose, λ−carrageenan, and κ−carrageenan are presented in graphical and numeric tabular form. The data provide basic polymer characterization info as also a specific structural and dynamical info for aqueous solutions of three industrially very important polymers (food additives that are available commercially. The commercial availability has much bigger impact to applications, research and connected advances, when the basic substances are well characterized – a feature that is still missing for many commercially available polymers unfortunately. Keywords: Food-grade polymers, Basic polymer characterization, Methyl cellulose, kappa-Carrageenan, lambda-Carrageenan

  3. Evaluation of femur of orchiectomized Guinea pigs by bone densitometry using dual-energy X-ray absorptiometry (DXA) and mechanical testing

    International Nuclear Information System (INIS)

    Estanislau, Cristiane de Abreu; Rahal, Sheila Canavese; Araujo, Fabio Andre Pinheiro de; Sergio Swain Muller; Louzada, Mario Jefferson Quirino; Estanislau, Caroline de Abreu

    2010-01-01

    The aim of this study was to evaluate the effects of castration on bones in the male guinea pigs and to observe whether mechanical testing correlates with dual-energy X-ray absorptiometry (DXA). Twelve male guinea pigs (Cavia porcellus), aged 21-27 days, and with average initial weight of 279 grams were used. The animals were equally allocated to two groups: GI - orchiectomized animals and GII - intact control animals. They underwent euthanasia at seven months following surgery. DXA measurement was performed at the mid third of the right femoral diaphysis in the cortical region and at the left femoral neck in order to verify its correlation with results of mechanical testing. Three-point bending test of right femur and axial compression test of left femur were performed. Bone mineral density of GI was significantly lower only at femoral neck. No differences were observed in the maximum load values between GI and GII for both bending and axial compression tests. The bending test revealed lower bone stiffness in GI compared to GII, but in the axial compression test no differences between groups were observed. Only left femur showed positive correlation coefficient between maximum load and bone mineral density according to Pearson's correlation coefficient. The results suggest that hormonal deprivation in guinea pigs induces reduction of bone mineral density, especially in the femoral neck area and reduction of bone stiffness in the mid-femoral diaphysis. (author)

  4. Stress degradation studies and development of stability-indicating TLC-densitometry method for determination of prednisolone acetate and chloramphenicol in their individual and combined pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Musharraf Syed

    2012-01-01

    Full Text Available Abstract A rapid and reproducible stability indicating TLC method was developed for the determination of prednisolone acetate and chloramphenicol in presence of their degraded products. Uniform degradation conditions were maintained by refluxing sixteen reaction mixtures for two hours at 80°C using parallel synthesizer including acidic, alkaline and neutral hydrolysis, oxidation and wet heating degradation. Oxidation at room temperature, photochemical and dry heating degradation studies were also carried out. Separation was done on TLC glass plates, pre-coated with silica gel 60F-254 using chloroform: methanol (14:1 v/v. Spots at Rf 0.21 ± 0.02 and Rf 0.41 ± 0.03 were recognized as chloramphenicol and prednisolone acetate, respectively. Quantitative analysis was done through densitometric measurements at multiwavelength (243 nm, λmax of prednisolone acetate and 278 nm, λmax of chloramphenicol, simultaneously. The developed method was optimized and validated as per ICH guidelines. Method was found linear over the concentration range of 200-6000 ng/spot with the correlation coefficient (r2 ± S.D. of 0.9976 ± 3.5 and 0.9920 ± 2.5 for prednisolone acetate and chloramphenicol, respectively. The developed TLC method can be applied for routine analysis of prednisolone acetate and chloramphenicol in presence of their degraded products in their individual and combined pharmaceutical formulations.

  5. Periprosthetic bone densitometry of the hip: Influence of design and hydroxyapatite coating on regional bone remodeling; 5 year follow-up

    International Nuclear Information System (INIS)

    Rosenthall

    2002-01-01

    Aim: To determine bone mineral density changes surrounding two differently designed titanium alloy porous-coated femoral hip prostheses (S-ROM and Multilock) as a function of time. Materials and Methods: The periprosthetic bone regions were defined by the seven Gruen zones. Measurements were obtained by DXA utilizing a dedicated software program (LUNAR ORTH). Inclusion criteria required that the patients were asymptomatic with Harris hip scores >95, showed no radiographic evidence of loosening and that they had primary implants. The protocol specified that bone measurements be obtained within one week after implantation as a baseline reference and at 6 months, 12 months and yearly thereafter. 111 consecutive S-ROM and 65 consecutive Multilock patients were enrolled in this ongoing prospective study. Of the 65 patients with Multilock implants, 25 had a 50 micron thick coating of hydroxyapatite-tricalcium phosphate (HA) sprayed over the porous surface and 40 were without coating. Results: At 6 months the mean BMD of all zones showed a significant decrease relative to the baseline measurement, varying from 6% to 17%. Gruen zones 2 to 6 exhibited variable degrees of recovery by 60 months. The maximum mineral losses were registered proximally in zone 1 (greater trochanter) and zone 7 (calcar and lesser trochanter), which are recognized sites of prosthetic stress shielding. The detailed results at 60 months are presented. In Gruen zone 1 the mineral loss in the S-ROM implant is significantly less the than either Multilock type. Also, mineral loss with Multilock-HA is about 55% less than the Multilock-uncoated. In Gruen zone 7 there is no difference between S-ROM and Multilock-uncoated, but Multilock-HA lost 44% less density than Multilock-uncoated. Conclusion: Regional bone remodeling appears to be related to prosthesis design. HA coating substantially and significantly reduces mineral loss in the proximal porous area; the mechanism is speculative

  6. Determination of volume fraction in biphasic flows oil-gas and water-gas using artificial neural network and gamma densitometry

    International Nuclear Information System (INIS)

    Peixoto, Philippe Netto Belache

    2016-01-01

    This study presents a methodology based on the principles of gamma ray attenuation to identify volume fractions in biphasic systems composed of oil-gas-water and gas which are found in the offshore oil industry. This methodology is based on the acknowledgment counts per second on the photopeak energy using a detection system composed of a NaI (Tl) detector, a source of 137 Cs without collimation positioned at 180 ° relative to the detector on a smooth stratified flow regime. The mathematical modeling for computational simulation using the code MCNP-X was performed using the experimental measurements of the detector characteristics (energy resolution and efficiency), characteristics of the material water and oil (density and coefficient attenuation) and measurement of the volume fractions. To predict these fractions were used artificial neural networks (ANNs), and to obtain an adequate training the ANNs for the prediction of volume fractions were simulated a larger number of volume fractions in MCNP-X. The experimental data were used in the set data necessary for validation of ANNs and the data generated using the computer code MCNP-X were used in training and test sets of the ANNs. Were used ANNs of type feed-forward Multilayer Perceptron (MLP) and analyzed two functions of training, Levenberg-Marquardt (LM) and gradient descent with momentum (GDM), both using the Backpropagation training algorithm. The ANNs identified correctly the volume fractions of the multiphase system with mean relative errors lower than 1.21 %, enabling the application of this methodology for this purpose. (author)

  7. A technique to identify annual growth rings in Eucalyptus grandis using annual measurements of diameter at breast height and gamma ray densitometry

    CSIR Research Space (South Africa)

    Naidoo, Sasha

    2010-06-01

    Full Text Available A technique was developed to identify annual growth rings in E. grandis using a combination of annual measurements of diameter at breast height (DBH) from permanent sample plot (PSP) datasets and bark-pith density profiles. By assessing the pattern...

  8. Absolute lung densitometer incorporating a Gd-153 source and CdTe detectors

    International Nuclear Information System (INIS)

    Kaufman, L.; Gamsu, G.; Savoca, C.; Swann, S.

    1976-01-01

    A low-cost portable non-invasive densitometer is described. While the present system is optimized for lung densitometry, similar configurations can be used for bone densitometry and in industrial applications

  9. Three-dimensional lung densitometer using CdTe detectors for diagnosis and evaluation of the progress of pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, L; Gamsu, G; Savoca, C; Swann, S [California Univ., San Francisco (USA)

    1977-02-01

    A low-cost portable non-invasive densitometer is described. While the present system is optimized for lung densitometry, similar configurations can be used for bone densitometry and in industrial applications.

  10. Clinical value of bone densitometry in partial androgen deficiency in aging male patients%中老年男性雄激素部分缺乏患者骨密度测定的临床价值

    Institute of Scientific and Technical Information of China (English)

    尹纪军; 王建然; 杨荣; 王青; 单文辉; 高波

    2011-01-01

    Objective To explore the characteristics of bone mineral density (BMD) and the incidence of osteoporosis in partial androgen deficiency in aging male (PADAM) patients.Methods Fifty-six PADAM patients (PADAM group) and 51 healthy persons (control group) were selected according to their age and body mass index (BMI),and measured their BMD in the second to fourth lumber and the neck of femur with the dual-energy C X-ray BMD measuring instrument.MES-01S20 muscle function analyzer was used to determinate the distribution and mechanical properties of muscle.The biochemical and bone metabolic markers and sexual hormones were collected and observed by multivariate stepwise regression analysis.Results Compared with control group,BMD significantly decreased in the Ward triangle,femoral neck and big rotor (P < 0.01 ) and no significant change in lumbar in PADAM group (P > 0.05 ),and the fracture strength of femoral neck (FS) and the lower-limb muscular strength (MS) also significantly decreased (P < 0.01 ).The incidence of osteopenia were 48.2% (27/56) and 35.3% ( 18/51 ),osteoporosis were 30.4% (17/56) and 21.6% ( 11/51 ) respectively in PADAM group and control group.There was significant difference between two groups (P<0.05).The BMD was positively correlated to BMI at the first to fourth lumber and negatively correlated to age,positively correlated to BMI and serum level of andrusol at the proximal left femur in the patients with PADAM.Conclusion BMD and the resistance to fracture aresignificantly lower in PADAM patients,and aging lower BMI and androgen deficiency are the risk factors of low BMD in PADAM patients.There is the potential of osteoporotic fracture risk,and it is important to strengthening the prevention and treatment of fractures in elderly PADAM patients.%目的 探讨中老年男性雄激素部分缺乏(PADAM)患者的骨密度(BMD)特点和骨质疏松的发生率.方法 采用双能X线骨密度仪对56例PADAM患者(PADAM组)和与之年龄、体重指数(BMI)相匹配的51例健康中老年人(对照组)进行腰椎及股骨颈等部位的BMD测定,采用MES-01S20肌肉功能分析仪测定肌肉分布和力学特性,并收集相关生化指标、激素水平及部分骨代谢指标进行多元逐步回归分析.结果 与对照组比较,PADAM组腰椎BMD无显著改变(P>0.05),而股骨颈、Ward三角区和大转子的BMD显著降低(P<0.01),且其抗骨折能力和下肢最大肌力显著降低(P<0.01).PADAM组和对照组的骨量减少发生率分别为48.2%(27/56)和35.3%(18/51),骨质疏松患病率分别为30.4%(17/56)和21.6%(11/51),两组比较差异有统计学意义(P<0.05).PADAM患者的腰椎BMD与BMI呈正相关,而股骨颈、Ward三角区、大转子的BMD与年龄呈负相关,与BMI、血清总睾酮呈正相关(P<0.05).结论 PADAM患者的BMD及抗骨折能力明显降低,存在骨质疏松性骨折的潜在危险,加强PADAM患者骨折的预防和治疗有重要意义.

  11. Standards and measurements for assessing bone health-workshop report co-sponsored by the International Society for Clinical Densitometry (ISCD) and the National Institute of Standards and Technology (NIST).

    Science.gov (United States)

    Bennett, Herbert S; Dienstfrey, Andrew; Hudson, Lawrence T; Oreskovic, Tammy; Fuerst, Thomas; Shepherd, John

    2006-01-01

    This article reports and discusses the results of the recent ISCD-NIST Workshop on Standards and Measurements for Assessing Bone Health. The purpose of the workshop was to assess the status of efforts to standardize and compare results from dual-energy X-ray absorptiometry (DXA) scans, and then to identify and prioritize ongoing measurement and standards needs.

  12. Official Positions for FRAX® clinical regarding falls and frailty: can falls and frailty be used in FRAX®? From Joint Official Positions Development Conference of the International Society for Clinical Densitometry and International Osteoporosis Foundation on FRAX®

    DEFF Research Database (Denmark)

    Masud, Tahir; Binkley, Neil; Boonen, Steven

    2011-01-01

    into the FRAX® model or, alternatively, to provide guidance to assist clinicians in clinical decision-making for patients with a falls history. It is clear that falls are a risk factor for fracture. Fracture probability may be underestimated by FRAX® in individuals with a history of frequent falls...... in addition to bone directed therapy. Clinicians should recognize that patients with frequent falls are at higher fracture risk than currently estimated by FRAX® and include this in decision-making. However, quantitative adjustment of the FRAX® estimated risk based on falls history is not currently possible......Risk factors for fracture can be purely skeletal, e.g., bone mass, microarchitecture or geometry, or a combination of bone and falls risk related factors such as age and functional status. The remit of this Task Force was to review the evidence and consider if falls should be incorporated...

  13. Quantitative analysis of the IgG and IgG subclass immune responses to chromosomal Pseudomonas aeruginosa beta-lactamase in serum from patients with cystic fibrosis by western blotting and laser scanning densitometry

    DEFF Research Database (Denmark)

    Petersen, T D; Ciofu, O; Pressler, T

    1996-01-01

    BACKGROUND: Antibodies against chromosomal beta-lactamase of Pseudomonas aeruginosa (a beta ab) are markers of the development of resistance of P aeruginosa to beta-lactam antibiotics in patients with cystic fibrosis and chronic lung infection. The role of these antibodies in patients with chronic...... of the chronic infection the a beta ab titres were higher in patients with good lung function than in those with poor lung function. CONCLUSIONS: The association of a weak IgG3 and a strong IgG4 a beta ab response suggests that the contribution of a beta ab antibodies to lung diseases mediated by immune...... complexes might be less important than other antipseudomonal antibodies. A beneficial neutralising effect of the a beta ab antibodies on the antibiotic destroying enzymes may be an additional factor....

  14. Determination of fat tissue area in the abdomen and evaluation of degree of obesity. Pt. 2. Clinical application of a unique densitometry CT technique for determination of fat tissue areas

    International Nuclear Information System (INIS)

    Nakayama, Fumie

    1995-01-01

    Abdominal CT scanning was performed to establish normal spectra of abdominal tissue areas on 291 subjects. Using the data file of measurements of abdominal fat tissue areas of 133 normal subjects, means and their standard deviations (S.D.) were calculated for each fat tissue area at the four levels for each gender. On 158 persons with abnormal body mass index (BMI) values, S.D.-distance of each fat tissue area from the mean of the control in each age group of each gender was compared with each other. Ratios of visceral fat tissue area to subcutaneous fat tissue area (V/S ratio) were also calculated. The visceral fat tissue area of normal male subjects was significantly larger at all the four levels than those of female ones, while the subcutaneous fat tissue area were smaller at all levels. Although the area of entire and subcutaneous fat tissues of female subjects showed a peak at the age of 50 years old, those in male subjects did not show any peak at any age group. Although there was a statistically significant correlation between values of BMI and S.D.-distance of each fat tissue area at each level, the coefficient between BMI and S.D.-distance of subcutaneous fat tissue area was very low at the level of 60 mm in female. Seven of 74 female subjects with abnormal BMI had more than 10 S.D.-distance of subcutaneous fat tissue area at all levels and 8 of them had more S.D.-distance than of all fat tissue area at any level. The V/S ratio of the male subjects was significantly larger than that in female. Besides, there was no correlation between V/S ratio and S.D.-distance of visceral fat tissue area in both male and female subjects. These findings indicate that the V/S ratio does not reflect the size of fat tissue area. The determination of fat tissue areas by the abdominal CT at several levels is quite a useful way for accurate evaluation of obesity. (S.Y.)

  15. Determination of fat tissue area in the abdomen and evaluation of degree of obesity. Pt. 2. Clinical application of a unique densitometry CT technique for determination of fat tissue areas

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Fumie [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1995-06-01

    Abdominal CT scanning was performed to establish normal spectra of abdominal tissue areas on 291 subjects. Using the data file of measurements of abdominal fat tissue areas of 133 normal subjects, means and their standard deviations (S.D.) were calculated for each fat tissue area at the four levels for each gender. On 158 persons with abnormal body mass index (BMI) values, S.D.-distance of each fat tissue area from the mean of the control in each age group of each gender was compared with each other. Ratios of visceral fat tissue area to subcutaneous fat tissue area (V/S ratio) were also calculated. The visceral fat tissue area of normal male subjects was significantly larger at all the four levels than those of female ones, while the subcutaneous fat tissue area were smaller at all levels. Although the area of entire and subcutaneous fat tissues of female subjects showed a peak at the age of 50 years old, those in male subjects did not show any peak at any age group. Although there was a statistically significant correlation between values of BMI and S.D.-distance of each fat tissue area at each level, the coefficient between BMI and S.D.-distance of subcutaneous fat tissue area was very low at the level of 60 mm in female. Seven of 74 female subjects with abnormal BMI had more than 10 S.D.-distance of subcutaneous fat tissue area at all levels and 8 of them had more S.D.-distance than of all fat tissue area at any level. The V/S ratio of the male subjects was significantly larger than that in female. Besides, there was no correlation between V/S ratio and S.D.-distance of visceral fat tissue area in both male and female subjects. These findings indicate that the V/S ratio does not reflect the size of fat tissue area. The determination of fat tissue areas by the abdominal CT at several levels is quite a useful way for accurate evaluation of obesity. (S.Y.).

  16. Primary Outcomes of Accelerated Epithelium-Off Corneal Cross-Linking in Progressive Keratoconus in Children: A 1-Year Prospective Study

    Directory of Open Access Journals (Sweden)

    Sherif A. Eissa

    2017-01-01

    Full Text Available Purpose. To evaluate corneal transparency following accelerated collagen cross-linking (ACXL in pediatric keratoconus. Design. A prospective interventional case series. Methods. This study included 47 eyes (25 patients, aged 9–14 years, with documented progressive keratoconus. After applying 0.1% riboflavin drops, ACXL was performed. Assessment included corrected distance visual acuity (CDVA, uncorrected visual acuity (UCVA, corneal haze, and corneal densitometry in grayscale units (GSU. Result. The mean baseline and corneal densitometry peaked at 3 months post-ACXL while central and posterior densitometry showed a statistically significant increase (P<0.05 and peaked at 8 months postoperatively. By 12 months, densitometry in all corneal layers (P≥0.99 and concentric zones (P≥0.97 reached near baseline values. Slit-lamp graded haze peaked at 1 month to 1.82 ± 0.65 (P<0.05 and declined to near baseline at 12 months (0.39 ± 0.58. There was a statistically significant increase in the mean UCVA and CDVA at 12 months. Conclusion. Total and anterior corneal densitometry peaked after 3 months, while central and posterior densitometry peaked after 8 months. Maximum haze was at 1 month post-ACXL. All corneal layers, concentric zone densitometry and haze reached near baseline values after 1 year. Scheimpflug densitometry showed weak correlation with CDVA over the 12-month follow-up period (r=−0.193.

  17. Determination of volume fraction in biphasic flows oil-gas and water-gas using artificial neural network and gamma densitometry; Determinacao de fracoes de volume em fluxos bifasicos oleo-gas e agua-gas utilizando redes neurais artificiais e densitometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Peixoto, Philippe Netto Belache

    2016-07-01

    This study presents a methodology based on the principles of gamma ray attenuation to identify volume fractions in biphasic systems composed of oil-gas-water and gas which are found in the offshore oil industry. This methodology is based on the acknowledgment counts per second on the photopeak energy using a detection system composed of a NaI (Tl) detector, a source of {sup 137}Cs without collimation positioned at 180 ° relative to the detector on a smooth stratified flow regime. The mathematical modeling for computational simulation using the code MCNP-X was performed using the experimental measurements of the detector characteristics (energy resolution and efficiency), characteristics of the material water and oil (density and coefficient attenuation) and measurement of the volume fractions. To predict these fractions were used artificial neural networks (ANNs), and to obtain an adequate training the ANNs for the prediction of volume fractions were simulated a larger number of volume fractions in MCNP-X. The experimental data were used in the set data necessary for validation of ANNs and the data generated using the computer code MCNP-X were used in training and test sets of the ANNs. Were used ANNs of type feed-forward Multilayer Perceptron (MLP) and analyzed two functions of training, Levenberg-Marquardt (LM) and gradient descent with momentum (GDM), both using the Backpropagation training algorithm. The ANNs identified correctly the volume fractions of the multiphase system with mean relative errors lower than 1.21 %, enabling the application of this methodology for this purpose. (author)

  18. Densitometria da vértebra dorsal, osso pleural e osso neural em tartarugas verdes hígidas por tomografia computadorizada quantitativa Densitometry of dorsal vertebrae, pleural bone and neural bone in healthy green sea turtles by quantitative computed tomography

    Directory of Open Access Journals (Sweden)

    Jannine Forattini de Oliveira

    2012-08-01

    Full Text Available A tomografia computadorizada quantitativa (TCQ é uma técnica com alta sensibilidade, aplicabilidade e precisão no diagnóstico de perda de massa óssea, entretanto a falta de valores de normalidade para animais silvestres limita a sua aplicação clínica. O presente estudo objetiva estabelecer valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural de tartarugas marinhas juvenis hígidas utilizando a TCQ. Para isso, utilizou-se um grupo experimental de cinco animais que foram submetidos a exames de tomografia computadorizada helicoidal, sendo as mensurações da radiodensidade óssea realizadas ao nível da terceira, quarta e quinta vértebras dorsais. Os valores médios de radiodensidade do osso trabecular das vértebras dorsais, osso pleural e osso neural foram, respectivamente, de 287,4±39,1, 1093,74±100,4 e 1089,6±86,5 unidades Hounsfield (HU. Estudos complementares devem ser realizados em diferentes espécies e faixas etárias de quelônios para favorecer a aplicação clínica desta técnica.Quantitative computed tomography (QCT is a technique with high sensitivity, applicability and accuracy in the diagnosis of bone loss; however the lack of normal values for wild animals limits their clinical application. This study aims to establish medium values radiodensity trabecular bone of the dorsal vertebrae, bone pleural and neural bone in healthy juvenile sea turtles using the QTC. For this we used an experimental group of five animals that underwent helical computed tomography, and measurements of bone radiodensity conducted at the level of the third, fourth and fifth dorsal vertebrae. The medium values of radiodensity trabecular bone of the dorsal vertebrae, pleural bone, and neural bone were respectively 287.4±39.1, 1093.74±100.4, and 1089.6±86.5 Hounsfield units (HU. Further studies should be performed in different species and ages of turtles to encourage the clinical application of this technique.

  19. Mass determination based on electron scattering in electron probe X-ray microanalysis of thin biological specimens

    International Nuclear Information System (INIS)

    Linders, P.W.J.

    1984-01-01

    This thesis describes the development of a method for mass determination of thin biological objects by quantitative electron microscopy. The practical realization of the mass determination consists of photographical recording with subsequent densitometry. (Auth.)

  20. [Computed tomography semiotics of osteonecrosis and sequestration in chronic hematogenic osteomyelitis].

    Science.gov (United States)

    D'iachkova, G V; Mitina, Iu L

    2007-01-01

    Based on the data of computed tomography, radiography and densitometry in 39 patients the authors describe in detail the signs of osteonecrosis and sequestration of different localization and extension.

  1. Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling

    NARCIS (Netherlands)

    Kerner, J.; Huiskes, H.W.J.; Lenthe, van G.H.; Weinans, H.; Rietbergen, van B.; Engh, C.A.; Amis, A.A.

    1999-01-01

    Periprosthetic adaptive bone remodelling after total hip arthroplasty can be simulated in computer models, combining bone remodelling theory with finite element analysis. Patient specific three-dimensional finite element models of retrieved bone specimens from an earlier bone densitometry (DEXA)

  2. Association between some CT characteristics of renal stones and extracorporeal shockwave lithotripsy success rate

    Directory of Open Access Journals (Sweden)

    Saedi D

    2012-06-01

    Conclusion: We strongly suggest performing densitometry in bone window for renal stones on pre-ESWL NCCT scanning and using an alternative treatment other than ESWL for stone densities greater than 740 HU.

  3. Bone mineral density test

    Science.gov (United States)

    BMD test; Bone density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis - BMD ... need to undress. This scan is the best test to predict your risk of fractures, especially of ...

  4. From bone biology to bone analysis.

    NARCIS (Netherlands)

    Schoenau, E.; Saggese, G.; Peter, F.; Baroncelli, G.I.; Shaw, N.J.; Crabtree, N.J.; Zadik, Z.; Neu, C.M.; Noordam, C.; Radetti, G.; Hochberg, Z.

    2004-01-01

    Bone development is one of the key processes characterizing childhood and adolescence. Understanding this process is not only important for physicians treating pediatric bone disorders, but also for clinicians and researchers dealing with postmenopausal and senile osteoporosis. Bone densitometry has

  5. X-ray evaluation of bone tissue density in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kotlubej, O.V.; Kamenets'kij, M.S.; Tkachenko, G.D.; Momot, N.V.

    1998-01-01

    Densitometry of hand and foot films of 111 patients with rheumatoid arthritis was performed. Twelve patients underwent CT of lumbar vertebra with tomodensitometry followed by analysis of the obtained graphic histograms. Photo densitometry of plain x-ray films and histographic analysis of CT scans allows to perform quantitative evaluation of the bone tissue density in rheumatoid arthritis and to reveal osteoporosis at early stages when x-ray features of the disease are absent

  6. DETERMINATION OF PROTOPINE IN FUMARIA DENSIFLORA DC. BY TLC- DENSITOMETRIC AND SPECTROPHOTOMETRIC METHOD

    OpenAIRE

    FAFAL, Tuğçe; ÖNÜR, Mustafa Ali

    2007-01-01

    The isoquinoline alkaloid protopine in Fumaria densiflora DC. (Fumariaceae) was quantitatively determined by TLC-densitometry and spectrophotometry. In TLC-densitometry two different solvent systems as toluene : chloroform : methanol : % 25 ammonium hydroxide (5:3:1:1) and cyclohexane : diethylamine (9:1) were used and protopine was detected as 0.351 and 0.352 % respectively. The content of protopine in Fumaria densiflora DC. was estimated as 0.366 % in spectrophotometric method. The quantita...

  7. Comparison and validation of methods to quantify Cry1Ab toxin from Bacillus thuringiensis for standardization of insect bioassays.

    Science.gov (United States)

    Crespo, André L B; Spencer, Terence A; Nekl, Emily; Pusztai-Carey, Marianne; Moar, William J; Siegfried, Blair D

    2008-01-01

    Standardization of toxin preparations derived from Bacillus thuringiensis (Berliner) used in laboratory bioassays is critical for accurately assessing possible changes in the susceptibility of field populations of target pests. Different methods were evaluated to quantify Cry1Ab, the toxin expressed by 80% of the commercially available transgenic maize that targets the European corn borer, Ostrinia nubilalis (Hübner). We compared three methods of quantification on three different toxin preparations from independent sources: enzyme-linked immunosorbent assay (ELISA), sodium dodecyl sulfate-polyacrylamide gel electrophoresis and densitometry (SDS-PAGE/densitometry), and the Bradford assay for total protein. The results were compared to those obtained by immunoblot analysis and with the results of toxin bioassays against susceptible laboratory colonies of O. nubilalis. The Bradford method resulted in statistically higher estimates than either ELISA or SDS-PAGE/densitometry but also provided the lowest coefficients of variation (CVs) for estimates of the Cry1Ab concentration (from 2.4 to 5.4%). The CV of estimates obtained by ELISA ranged from 12.8 to 26.5%, whereas the CV of estimates obtained by SDS-PAGE/densitometry ranged from 0.2 to 15.4%. We standardized toxin concentration by using SDS-PAGE/densitometry, which is the only method specific for the 65-kDa Cry1Ab protein and is not confounded by impurities detected by ELISA and Bradford assay for total protein. Bioassays with standardized Cry1Ab preparations based on SDS-PAGE/densitometry showed no significant differences in LC(50) values, although there were significant differences in growth inhibition for two of the three Cry1Ab preparations. However, the variation in larval weight caused by toxin source was only 4% of the total variation, and we conclude that standardization of Cry1Ab production and quantification by SDS-PAGE/densitometry may improve data consistency in monitoring efforts to identify changes in

  8. Investigation on liver fast metabolism with CT

    International Nuclear Information System (INIS)

    Huebener, K.H.; Schmitt, W.G.H.

    1981-01-01

    Measurements of the density of normal and diffusely diseased liver parenchyma show a significant difference only in fatty liver. A linear relationship between the fat content and physical density has been demonstrated. Computed tomographic densitometry of liver tissue correlates well with physical in vitro measurements of fat content and is sufficiently accurate for clinical use. Other types of liver diseases cannot be differentiated by densitometry, Lipolisis in fatty liver in chronic alcoholism alcohol withdrawal has been investigated. It has been found that a rate of decrease of the fatty degeneration of the liver equals to 1 percent/day. Fatty degeneration of the liver in acute pancreatitis and other diseases have been also investigated. CT densitometry of the liver should be considered as a useful routine clinical method to determine the fat content of liver. (author)

  9. An experimental study on the change of bone mineral metabolism after irradiation

    International Nuclear Information System (INIS)

    Chin, Hae Yun; Lee, Sang Rae

    1988-01-01

    Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The bone densitometry and bone scintigraphy and valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absorptiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before presentation of the osteoradionecrosis can be developed at low dose irradiation and confirmed by bone densitometry, bone scanning, and histopathology.

  10. Investigation on liver fast metabolism with CT

    Energy Technology Data Exchange (ETDEWEB)

    Huebener, K.H.; Schmitt, W.G.H. (Heidelberg Univ. (Germany, F.R.). Pathologisches Inst.)

    1981-01-01

    Measurements of the density of normal and diffusely diseased liver parenchyma show a significant difference only in fatty liver. A linear relationship between the fat content and physical density has been demonstrated. Computed tomographic densitometry of liver tissue correlates well with physical in vitro measurements of fat content and is sufficiently accurate for clinical use. Other types of liver diseases cannot be differentiated by densitometry, Lipolisis in fatty liver in chronic alcoholism alcohol withdrawal has been investigated. It has been found that a rate of decrease of the fatty degeneration of the liver equals to 1 percent/day. Fatty degeneration of the liver in acute pancreatitis and other diseases have been also investigated. CT densitometry of the liver should be considered as a useful routine clinical method to determine the fat content of liver.

  11. Tokai densitometer manual

    International Nuclear Information System (INIS)

    Sprinkle, J.K. Jr.; Hsue, S.T.; Junck, K.

    1987-01-01

    In 1979, the Tokai densitometer was installed at the Tokai Reprocessing Plant in Tokai, Japan. It uses a nondestructive active technique (K-edge absorption densitometry) to assay solutions for plutonium content. The original hardware was upgraded in 1984 and 1985. This manual describes the instrument's operation after the upgrade. 2 refs

  12. Seeded emulsion polymerization of butadiene. 2. Effects of persulfate and tert-dodecyl mercaptan

    NARCIS (Netherlands)

    Verdurmen, E.M.F.J.; Geurts, J.M.; Verstegen, J.M.; Maxwell, I.A.; German, A.L.

    1993-01-01

    The kinetics of the emulsion polymn. of butadiene at 60 Deg in Smith-Ewart interval III were investigated using sodium persulfate as initiator. Monomer conversion was based on gravimetrically calibrated online densitometry. Plots of the product of the propagation rate coeff., Kp, and the av. no. of

  13. Seeded emulsion polymerization of butadiene. 1. The propagation rate coefficient

    NARCIS (Netherlands)

    Verdurmen, E.M.F.J.; Dohmen, E.H.M.; Verstegen, J.M.; Maxwell, I.A.; German, A.L.; Gilbert, R.G.

    1993-01-01

    The kinetics of the emulsifier-free, seeded polymn. of butadiene (I) at 60 Deg in Smith-Ewart interval III were studied in presence of Na peroxodisulfate initiator and tert-dodecyl mercaptan. The fractional conversion was based on gravimetrically calibrated online densitometry and was highly

  14. Modeling corewood-outerwood transition in loblolly pine using wood specific gravity

    Science.gov (United States)

    Christian R. Mora; H. Lee Allen; Richard F. Daniels; Alexander Clark

    2007-01-01

    A modified logistic function was used for modeling specific-gravity profiles obtained from X-ray densitometry analysis in 675 loblolly pine (Pinus taeda L.) trees in four regeneration trials. Trees were 21 or 22 years old at the time of the study. The function was used for demarcating corewood, transitional, and outerwood zones. Site and silvicultural effects were...

  15. Basic strategies for valid cytometry using image analysis

    NARCIS (Netherlands)

    Jonker, A.; Geerts, W. J.; Chieco, P.; Moorman, A. F.; Lamers, W. H.; van Noorden, C. J.

    1997-01-01

    The present review provides a starting point for setting up an image analysis system for quantitative densitometry and absorbance or fluorescence measurements in cell preparations, tissue sections or gels. Guidelines for instrumental settings that are essential for the valid application of image

  16. Response of cortical bone to antiresorptive treatment

    DEFF Research Database (Denmark)

    Hyldstrup, Lars; Jørgensen, J T; Sørensen, T K

    2001-01-01

    of the spine, hip, and forearm. Longitudinal changes in bone densitometry were compared with changes captured by DXR: BMD evaluated by DXR (BMDDXR), cortical thickness of the second metacarpal (CTMC2), and porosity of cortical bone. The expected annual postmenopausal reduction in BMD in the control group...... treatment regimens used in the prevention of osteoporosis....

  17. The second highest chromosome count among vertebrates is observed in cultured sturgeon and is associated with genome plasticity

    Czech Academy of Sciences Publication Activity Database

    Havelka, M.; Bytyutskyy, D.; Symonová, R.; Ráb, Petr; Flajšhans, M.

    2016-01-01

    Roč. 48, č. 12 (2016) ISSN 0999-193X R&D Projects: GA ČR GA14-02940S Institutional support: RVO:67985904 Keywords : sturgeon * spontaneous autopolyploidy * image-analysis densitometry Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.964, year: 2016

  18. Sex and age specific prediction formulas for estimating body composition from bioelectrical impedance : a cross-validation study

    NARCIS (Netherlands)

    Deurenberg, P.; van der Kooy, K; Leenen, R; Weststrate, J A; Seidell, J C

    In 827 male and female subjects, with a large variation in body composition and an age range of 7-83 years, body composition was measured by densitometry, anthropometry and bioelectrical impedance. The relationship between densitometrically determined fat free mass (FFM) with body impedance (R),

  19. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  20. A Review on Chiral Chromatography and its Application to the ...

    African Journals Online (AJOL)

    MoZarD

    amounts of material and is for measuring the relative proportions of ... the stationary phase must themselves be made chiral, giving differing ... electrophoretic medium that change it to chiral mobile phase (Eliel, et ... column containing a chiral stationary phase is also called a chiral ... densitometry, and a TLC method for the.

  1. Radiophotometric diagnostics of osteodystrophy in cows during early milking period

    International Nuclear Information System (INIS)

    Samotaev, A.A.

    1988-01-01

    Dynamic standard induced of the fifth caudal vertebra in practically healthy caws, on the base of which evaluation of skeletal clinical state is performed, are presented. It is ascertained that improved roentgena densitometry methods can be applied by specialists in diagnostics of diseases accompanied by a change in mineral saturation of bone tissue, for a more objective opinion concerning the skeletal state

  2. Response of cortical bone to antiresorptive treatment

    DEFF Research Database (Denmark)

    Hyldstrup, Lars; Jørgensen, J T; Sørensen, T K

    2001-01-01

    A total of 113 postmenopausal women (69 controls, 33 using hormone replacement therapy (HRT), and 11 using bisphosphonate) were evaluated twice over 2 years with a new noninvasive, radiogrammetry-based technique called digital X-ray radiogrammetry (DXR) and conventional bone densitometry of the s...

  3. System for the chemical professing and evaluation gives the residual thickness the gives detecting for gives appearances LR115 type 2

    International Nuclear Information System (INIS)

    Carrazana Gonzalez, J.A.; Tomas Zerquera, J.; Prendes Alonso, M.

    1998-01-01

    In this work the system is described built in the CPHR for the homogeneous chemical processing gives detecting gives nuclear appearances. A new developed method is exposed, based on the application gives the technique optical densitometry, for the precise estimate gives the residual thickness, gives detecting, gives nuclear appearances LR115 type 2 after the process gives chemical engraving

  4. X-ray L/sub III/-edge densitometer for assay of mixed S.N.M. solutions

    International Nuclear Information System (INIS)

    Russo, P.A.; Canada, T.R.; Langner, D.G.; Tape, J.W.; Hsue, S.T.; Cowder, L.R.; Mosley, W.C.; Reynolds, L.; Thompson, M.C.

    1979-01-01

    Simultaneous nondestructive analysis of uranium and plutonium in coprocessed solutions is accomplished using L/sub III/-edge densitometry in at-line instrumentation. The densitometer measures the transmission through solutions of a continuous x-ray spectrum, and gives accuracies of approximately one-half percent and three percent for uranium and plutonium concentrations respectively

  5. Body fat measurement among Singaporean Chinese, Malays and Indians: a comparative study using a four-compartment model and different two-compartment models

    NARCIS (Netherlands)

    Deurenberg-Yap, M.; Schmidt, G.; Staveren, van W.A.; Hautvast, J.G.A.J.; Deurenberg, P.

    2001-01-01

    This cross-sectional study compared body fat percentage (BF€obtained from a four-compartment (4C) model with BF␏rom hydrometry (using 2H2O), dual-energy X-ray absorptiometry (DXA) and densitometry among the three main ethnic groups (Chinese, Malays and Indians) in Singapore, and determined the

  6. Assessment of local changes of cerebral perfusion and blood concentration by ultrasound harmonic B-mode contrast measurement in piglet.

    NARCIS (Netherlands)

    Wijk, M.C. van; Klaessens, J.H.G.M.; Hopman, J.C.W.; Liem, K.D.; Thijssen, J.M.

    2003-01-01

    This study tested the hypothesis that changes in the blood concentration, and possibly in the perfusion, of different areas in the brain can be assessed by the use of ultrasound contrast agent (CA) and (linear) echo densitometry. The experiments were performed with piglets (n=3) under general

  7. Ion exchange synthesis and thermal characteristics of some [N

    Indian Academy of Sciences (India)

    These ionic liquids (ILs) were characterized using thermal methods, infrared spectroscopy and densitometry. Thermophysical properties such as density, coefficient of volume expansion, heat of fusion, heat capacity and thermal energy storage capacity were determined. Thermal conductivity of the samples was determined ...

  8. A comparison between composition and density of the fat-free mass of young adult Singaporean Chinese and Dutch Caucasians

    NARCIS (Netherlands)

    Werkman, A.; Deurenberg-Yap, M.; Schmidt, G.; Deurenberg, P.

    2000-01-01

    The body composition was measured in 30 female Singapore Chinese and 34 female Dutch Caucasians aged (mean ± SD) 22.7 ± 3.6 years and in 39 male Singapore Chinese and 39 male Dutch Caucasians aged 23.3 ± 3.2 years. Methods: The body fat percentage (BF€was measured using densitometry and deuterium

  9. Direct X-ray radiogrammetry versus dual-energy X-ray absorptiometry: assessment of bone density in children treated for acute lymphoblastic leukaemia and growth hormone deficiency

    NARCIS (Netherlands)

    van Rijn, Rick R.; Boot, Annemieke; Wittenberg, Rianne; van der Sluis, Inge M.; van den Heuvel-Eibrink, Marry M.; Lequin, Maarten H.; de MuinckKeizer-Schrama, Sabine M. P. F.; van Kuijk, Cornelis

    2006-01-01

    BACKGROUND: In recent years interest in bone densitometry in children has increased. OBJECTIVE: To evaluate the clinical application of digital X-ray radiogrammetry (DXR) and compare the results with those of dual-energy X-ray absorptiometry (DXA). MATERIALS AND METHODS: A total of 41 children with

  10. Experimental investigations on the weakening of pulsed X-radiation by contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Moldenhauer, K

    1973-07-25

    In order to be able to carry out a videodensitometry simultaneously with the cineangiocardiography with pulsed X-rays, the weakening of the X-radiation by contrast media is more closely examined and a calibration of the amplitudes is carried out. The determination of the extinction curves for different parts of the X-ray pulses show that under unfavourable conditions (high voltage, low tube current, no Cu filtration) the spectrum is displaced to larger wavelengths, white an influence on the weakness coefficient only occurs after the intensity has fallen to 10% of the impulse maximum. On the other hand, the quantity depedence of the extinction coefficient is significant. The densitometry simulations performed with a digital computer using empirically gained calibration curves show that a quantitative densitometry is possible even if the Lambert-Beer law is not valid.

  11. Predictors of bone mineral density reduction in adolescents with anorexia nervosa.

    Science.gov (United States)

    Castro, J; Lázaro, L; Pons, F; Halperin, I; Toro, J

    2000-11-01

    To determine which variables are associated with a significant reduction in bone mineral density (BMD) in adolescent anorexia nervosa and to establish guidelines for indication of bone densitometry. One hundred seventy patients (treated from 1997 until 1999), aged 10 to 17 years, with a DSM-IV diagnosis of anorexia nervosa were evaluated by dual-energy-x-ray absorptiometry in the lumbar spine (L2-L4) and the femoral neck. The results were compared with the normative data for BMD values by age and sex in Spanish adolescents. 44.1% of patients had osteopenia at the lumbar spine and 24.7% at the femoral neck. The following variables were related to osteopenia: more than 12 months since onset of the disorder (p anorexia nervosa patients with the characteristics outlined above are at high risk of reduced BMD, and densitometry is recommended to determine the degree of osteopenia.

  12. A status report on dual energy x-ray absorptiometry quality control in Korea

    International Nuclear Information System (INIS)

    Kim, Jung Su; Ro, Young Hoon; Lee, In Ju; Kim, Jung Min; Kim, Sung Su; Kim, Kyoung Ah

    2016-01-01

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude

  13. An Experimental Study on the Change of Bone Mineral Metabolism After Irradiation

    International Nuclear Information System (INIS)

    Hong, Sung Woon; Lim, Sang Moo; Jang, Ja June; Lee, Jin Oh; Kang, Tae Woong

    1990-01-01

    Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of Cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absorptiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before the presentation of the osteoradionecrosis can be diagnosed early with the dual photon absorptiometry and bone scintigraphy.

  14. Experimental investigations on the weakening of pulsed X-radiation by contrast media

    International Nuclear Information System (INIS)

    Moldenhauer, K.

    1973-01-01

    In order to be able to carry out a videodensitometry simultaneously with the cineangiocardiography with pulsed X-rays, the weakening of the X-radiation by contrast media is more closely examined and a calibration of the amplitudes is carried out. The determination of the extinction curves for different parts of the X-ray pulses show that under unfavourable conditions (high voltage, low tube current, no Cu filtration) the spectrum is displaced to larger wavelengths, white an influence on the weakness coefficient only occurs after the intensity has fallen to 10% of the impulse maximum. On the other hand, the quantity depedence of the extinction coefficient is significant. The densitometry simulations performed with a digital computer using empirically gained calibration curves show that a quantitative densitometry is possible even if the Lambert-Beer law is not valid. (ORU/LH) [de

  15. A status report on dual energy x-ray absorptiometry quality control in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su [Dept. of Radiogic Technology, Chungbuk Health and Science University, Cheongju (Korea, Republic of); Ro, Young Hoon; Lee, In Ju; Kim, Jung Min [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); Kim, Sung Su [Dept. of Healthcare Management, Cheongju University, Cheongju (Korea, Republic of); Kim, Kyoung Ah [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-12-15

    Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

  16. Changes in fat-free mass in obese subjects after weight loss : a comparison of body composition measures

    NARCIS (Netherlands)

    van der Kooy, K; Leenen, R; Deurenberg, P.; Seidell, J C; Westerterp, K R; Hautvast, J.G.A.J.

    Estimates of body composition by densitometry were made in 84 apparently healthy subjects (42 men, 42 women) with a mean age of 40 +/- 6 years (mean +/- s.d.), before and after weight loss. The initial body mass index (BMI) was 30.7 +/- 2.3 kg/m2 and the achieved weight loss on a 4.2 MJ/day energy

  17. Seven year follow-up after advanced surface ablation with excimer laser for treatment of myopia: Long-term outcomes of cooling PRK and LASEK.

    OpenAIRE

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob; Vestergaard, Anders Højslet

    2014-01-01

    Purpose: To evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA and CDVA), corneal haze, corneal densitometry and patient satisfaction up to 7 years after Photorefractive Keratectomy with cooling (cPRK) and Laser-Assisted Sub-epithelial Keratectomy (LASEK) for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Methods: Retrospective follow-up study of eyes t...

  18. Localization of 125I-insulin binding sites in the rat hypothalamus by quantitative autoradiography

    International Nuclear Information System (INIS)

    Corp, E.S.; Woods, S.C.; Figlewicz, D.P.; Porte, D. Jr.; Baskin, D.G.; Dorsa, D.M.

    1986-01-01

    In vitro autoradiography and computer video densitometry were used to localize and quantify binding of 125 I-insulin in the hypothalamus of the rat brain. Highest specific binding was found in the arculate, dorsomedial, suprachiasmatic, paraventricular and periventricular regions. Significantly lower binding was present in the ventromedial nucleus and median eminence. The results are consistent with the hypothesis that insulin modulates the neural regulation of feeding by acting at sites in the hypothalamus. (author)

  19. Hybrid KED/XRF measurement of minor actinides in reprocessing plants

    International Nuclear Information System (INIS)

    Hsue, S.T.; Collins, M.L.

    1996-01-01

    Minor actinides have received considerable attention recently in the nuclear power industry. Because of their potential value as recycle fuels in thermal and breeder reactors, reprocessing plants may have an economic incentive to extract Np, Am, and Cm from their waste streams. This report discusses the technique of hybrid densitometry and its potential to measure Np and Am in reprocessing plants. Precision estimates are made for the hybrid analysis of Np and Am in two types of dissolver solutions

  20. Nutritional risk factors for postmenopausal osteoporosis

    OpenAIRE

    Olfa Berriche; Amrouche Chiraz; Rym Ben Othman; Hamdi Souheila; Ines Lahmer; Chaabani Wafa; Imen Sebai; Haifa Sfar; Feten Mahjoub; Henda Jamoussi

    2017-01-01

    Background: Osteoporosis is a bone disease that combines both a decrease in bone density and its internal architecture changes. Nutrition is one of the major determinants of osteoporosis. Aim: The purpose of our study was to identify nutritional risk factors of osteoporosis of two groups of osteoporotic women and witnesses. Methods: We conducted a comparative cross-sectional study including 60 postmenopausal women and screening for osteoporosis by a bone densitometry, recruited the outp...

  1. The influence of high gravity in PbSn eutectic alloy

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, F.E.; Toledo, R.C.; Poli, A.K.S.; An, C.Y.; Bandeira, I.N., E-mail: filipe.estevao@gmail.com, E-mail: chen@las.inpe.br [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)

    2014-07-01

    The study of materials processed in centrifuges improves the understanding of the acceleration influence in the convection behavior in materials processing. This work aims to study the influence of high gravity in PbSn eutectic alloy solidification using a small centrifuge designed and built in the Associate Laboratory of Sensors and Materials of the Brazilian Space Research Institute (LAS/INPE). The samples were analyzed by densitometry and scanning electron microscopy (SEM). (author)

  2. Digital imaging with a pressurized Xenon filled MWPC working at a high data rate

    International Nuclear Information System (INIS)

    Bellazzini, R.; Brez, A.; Del Guerra, A.; Massai, M.M.; Torquati, M.R.; Franchi, M.; Perri, G.

    1984-01-01

    A multiwire proportional chamber based detection system for medical imaging is presented. The system consists of a pressurized xenon filled MWPC and of a monochromatic fluorescent, X-ray source using a conventional diagnostic tube with various target filter combinations. The main performance of the system are: 10% efficiency, 30% energy resolution 500 micro m spatial resolution, +-5 uniformity. The preliminary results of the application of this system to bone densitometry are presented

  3. Proposal to evaluate the use of ERTS-A imagery in mapping and managing soil and range resources in the Sand Hills Region of Nebraska

    Science.gov (United States)

    Drew, J. V. (Principal Investigator)

    1973-01-01

    The author has identified the following significant results. There appears to be a direct relationship between densitometry values obtained with MSS band 5 imagery and forage density for those range sites measured on the imagery, provided site category identification is indicated by other forms of imagery or ground truth. Overlap of density values for different site categories with differing forage condition classes does not allow assigning a given forage density value for a given densitometer value unless the range site category is known.

  4. Heavy water standards. Qualitative analyses, sample treating, stocking and manipulation

    International Nuclear Information System (INIS)

    Pavelescu, M.; Steflea, D.; Mihancea, I.; Varlam, M.; Irimescu, R.

    1995-01-01

    This paper presents methods and procedures for measuring heavy water concentration, and also sampling, stocking and handling of samples to be analysed. The main concentration analysis methods are: mass spectrometry, for concentrations less then 1%, densitometry, for concentrations within the range 1% - 99% and infrared spectrometry for concentrations above 99%. Procedures of sampling, processing and purification appropriate to these measuring methods were established. 1 Tab

  5. Digital imaging with a pressurized xenon filled MWPC working at a high data rate

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R; Brez, A; Del Guerra, A; Massai, M M; Torquati, M R; Franchi, M; Perri, G

    1985-12-15

    A MWPC based detection system for medical imaging is presented. The system consists of a pressurized Xenon filled MWPC and of a monochromatic, fluorescent, X-ray source using a conventional diagnostic tube with various target/filter combinations. The main performance of the system are: 10% efficiency, 30% energy resolution, 500 m spatial resolution, +-5 uniformity. The preliminary results of the application of this system to bone densitometry are presented. (orig.).

  6. Digital imaging with a pressurized xenon filled MWPC working at a high data rate

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R; Brez, A; Del Guerra, A; Massai, M M; Torquati, M R [Pisa Univ. (Italy). Ist. di Fisica; Istituto Nazionale di Fisica Nucleare, Pisa (Italy)); Franchi, M; Perri, G [Pisa Univ. (Italy). Ist. di Radiologia

    1984-12-15

    A MWPC based detection system for medical imaging is presented. The system consists of a pressurized Xenon filled MWPC and of a monochromatic, fluorescent, X-ray source using a conventional diagnostic tube with various target/filter combinations. The main performance of the system are: 10% efficiency, 30% energy resolution, 500 ..mu..m spatial resolution, +-5 uniformity. The preliminary results of the application of this system to bone densitometry are presented.

  7. New procedures in nuclear medicine

    International Nuclear Information System (INIS)

    Spencer, R.P.

    1989-01-01

    The authors review the recent emergence of functional studies in nuclear medicine in this critical and informative text. The new procedures are presented in terms of their underlying physiology, indications, contraindications, methodology, results, interpretation and relationship to other evaluations. The volume includes discussions on the central nervous system, interventional studies, cardiac studies, bone densitometry, plus radiolabeled antibodies, radiolabeling of blood elements and flow and distribution

  8. Chemometric Analysis of High Molecular Mass Glutenin Subunits and Image Data of Bread Crumb Structure from Croatian Wheat Cultivars

    OpenAIRE

    Zorica Jurković; Rezica Sudar; Damir Magdić; Daniela Horvat; Želimir Kurtanjek

    2002-01-01

    The aim of this work is to investigate functional relationships among wheat properties, high molecular mass (weight) (HMW) glutenin subunits and bread quality produced from eleven Croatian wheat cultivars by chemometric analysis. HMW glutenin subunits were fractionated by sodium dodecylsulfate polyacrylamid gel electrophoresis (SDS-PAGE) and subsequently analysed by scanning densitometry in order to quantify HMW glutenin fractions. Wheat properties are characterised by four variables: protein...

  9. Neural Plasticity and Neurorehabilitation Following Traumatic Brain Injury

    Science.gov (United States)

    2011-04-01

    of Theresa Jones for sectioning and staining . To date, the brains have been sectioned and one set stained for Nissl . Using the Nissl stained ...three rehabilitations decreases contusion size compared to CCI-Yoked (#p=0.051). The remaining sets of brain sections have been stained with...optical densitometry, as appropriate, given staining patterns. Sample locations will be the remaining sensorimotor cortex around the injury, in the

  10. Calcium homestasis markers of bone metabolism in feline hyperthyroidism - A review

    OpenAIRE

    Cardoso, M. J L; Muniz, L. M R [UNESP; Gasparini, T. J.; Melussi, M.

    2007-01-01

    Hyperthyroidism is the most frequent endocrine disease in old-aged cats. It is a illness provoked by the excess of circulating thyroid hormones. Hyperthyroidism causes alteration in bone metabolism with predominance of activity resorption. The evaluation of bone metabolism can be made by measuring serum and urinary markers of bone metabolism or bone mineral densitometry. Osteoblasts are responsible cells for bone formation while the osteoclasts are for resorption. In physiological situation o...

  11. Physical- chemical changes in irradiated sodium alginate algimar

    International Nuclear Information System (INIS)

    Rapado Paneque, Manuel; Alazanes, Sonia; Sainz Vidal, Dianelys; Wandrey, Christine

    2003-01-01

    The effect of gamma radiation on the physical-chemical properties of sodium alginate Algimar has been investigated. dilution viscometric, densitometry FTIR spectroscopy served to identify modifications. Decreasing intrinsic, viscosities clearly revealed chain cleavage for both solid alginate indicate that chain degradation occurs without significant change of the chemical structure, The obtained results have practical implication change of the chemical structure. The obtained results have practical implication in the field of radiation modification and sterilization of sodium alginate used for microcapsule formation

  12. Corneal clarity measurements in healthy volunteers across different age groups: Observational study.

    Science.gov (United States)

    Alzahrani, Khaled; Carley, Fiona; Brahma, Arun; Morley, Debbie; Hillarby, M Chantal

    2017-11-01

    The aim of this study was to standardize and investigate the changes in corneal clarity with age. Densitometry software for the Oculus Pentacam was used to examine corneal clarity at different age groups.A total of 192 eyes from 97 healthy participants were included in this cohort comparative nonrandomized, cross-sectional study. An Oculus Pentcam was used to image the cornea of healthy participants grouped by age (between 10 and 70 years old). Data from the densitometry output have been used to determine clarity in concentric zones and different depths of the cornea.Corneal densitometry (CD) across all ages showed significant differences between groups when divided into the following layers: anterior, central, and posterior or divided into 0 to 2, 2 to 6, and 6 to 10 mm concentric zones (P age in all 3 layers of the periphery (6-10 mm) (P age group had lower clarity than the 20 to 30-age group (P age is differed when the cornea is divided into layers and zones. This study suggests that there are other factors that may play an essential role in corneal clarity as well as age.

  13. Comparative analysis on arthroscopic sutures of large and extensive rotator cuff injuries in relation to the degree of osteopenia

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2015-02-01

    Full Text Available OBJECTIVE: To analyze the results from arthroscopic suturing of large and extensive rotator cuff injuries, according to the patient's degree of osteopenia.METHOD: 138 patients who underwent arthroscopic suturing of large and extensive rotator cuff injuries between 2003 and 2011 were analyzed. Those operated from October 2008 onwards formed a prospective cohort, while the remainder formed a retrospective cohort. Also from October 2008 onwards, bone densitometry evaluation was requested at the time of the surgical treatment. For the patients operated before this date, densitometry examinations performed up to two years before or after the surgical treatment were investigated. The patients were divided into three groups. Those with osteoporosis formed group 1 (n = 16; those with osteopenia, group 2 (n = 33; and normal individuals, group 3 (n = 55.RESULTS: In analyzing the University of California at Los Angeles (UCLA scores of group 3 and comparing them with group 2, no statistically significant difference was seen (p = 0.070. Analysis on group 3 in comparison with group 1 showed a statistically significant difference (p = 0.027.CONCLUSION: The results from arthroscopic suturing of large and extensive rotator cuff injuries seem to be influenced by the patient's bone mineral density, as assessed using bone densitometry.

  14. [Evaluation of bone mineral density in children with sickle cell disease].

    Science.gov (United States)

    Garrido Colino, C; Beléndez Bieler, C; Pérez Díaz, M; Cela de Julián, E

    2015-04-01

    To evaluate bone mineral density (BMD) in children with sickle cell disease (SCD) in the Community of Madrid. The BMD was estimated in 40 children with SCD, and with an age range between 3 and 16 years, using densitometry (DXA), as recommended by the International Society for Clinical Densitometry (ISCD). The mean age at the time of the study was 7.97±3.95 years, the mean value of the DXA expressed in Z -score was -0.91±1.46 with a range of minimum values - 5.30 and 2.30 maximum. More than half (57.5%) of all the children had normal BMD (Z>-1), 25% had low BMD (Z between -1 and -2), and 17.5% showed an abnormal Z -score values of osteoporosis (Z -score<-2). The Pearson linear correlation was statistically significant between Z -score value and the haemoglobin level (r=0.368, p=.019), finding no correlation with the levels of 25 (OH) vitamin D. Prospective studies are needed with a larger number of patients to understand the future implications of bone densitometry changes and associated risk factors. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  15. Study and qualification of solid and gaseous captors designated to X imaging at around 60 keV; Etude et qualification de capteurs solide et gazeux en vue de leur utilisation en imagerie X autour de 60 keV

    Energy Technology Data Exchange (ETDEWEB)

    Ismaili, Y. [Caen Univ., 14 (France). Lab. de Physique Corpusculaire

    1996-09-01

    X ray detection techniques are used in numerous fields: industrial applications, security systems, scientific research and medicine. Among the medical applications, the dual energy detection of X-rays around 60 keV is used for bone densitometry. This thesis presents the design, realization and characterization of several kinds of detectors that could be suitable for X-ray imaging around 60 keV, bone densitometry being one the possible applications. The first part of this thesis is devoted to the realization of an original three-step gaseous detector coupled with a microchannel plate converter. The operating principle, the characteristics and the performance of such a bi-dimensional detector are discussed. Our study has allowed us to improve the efficiency by a factor of two, as compared to other systems based on the same principle. The obtained images have an excellent spatial resolution and can also be used to discriminate materials with different compositions. The work related to the study of a mono-dimensional detector constitutes the second part of the thesis. It is about the evaluation and optimization of a 8 element array made of Cd Te (Cadmium Telluride) which is a semi-conductor operating at room temperature. The tests carried-out with this detector show that it is a promising candidate for bone densitometry measurements. (author) 48 refs.

  16. Study and qualification of solid and gaseous captors designated to X imaging at around 60 keV

    International Nuclear Information System (INIS)

    Ismaili, Y.

    1996-09-01

    X ray detection techniques are used in numerous fields: industrial applications, security systems, scientific research and medicine. Among the medical applications, the dual energy detection of X-rays around 60 keV is used for bone densitometry. This thesis presents the design, realization and characterization of several kinds of detectors that could be suitable for X-ray imaging around 60 keV, bone densitometry being one the possible applications. The first part of this thesis is devoted to the realization of an original three-step gaseous detector coupled with a microchannel plate converter. The operating principle, the characteristics and the performance of such a bi-dimensional detector are discussed. Our study has allowed us to improve the efficiency by a factor of two, as compared to other systems based on the same principle. The obtained images have an excellent spatial resolution and can also be used to discriminate materials with different compositions. The work related to the study of a mono-dimensional detector constitutes the second part of the thesis. It is about the evaluation and optimization of a 8 element array made of Cd Te (Cadmium Telluride) which is a semi-conductor operating at room temperature. The tests carried-out with this detector show that it is a promising candidate for bone densitometry measurements. (author)

  17. Quantification of breast arterial calcification using full field digital mammography

    International Nuclear Information System (INIS)

    Molloi, Sabee; Xu Tong; Ducote, Justin; Iribarren, Carlos

    2008-01-01

    Breast arterial calcification is commonly detected on some mammograms. Previous studies indicate that breast arterial calcification is evidence of general atherosclerotic vascular disease and it may be a useful marker of coronary artery disease. It can potentially be a useful tool for assessment of coronary artery disease in women since mammography is widely used as a screening tool for early detection of breast cancer. However, there are currently no available techniques for quantification of calcium mass using mammography. The purpose of this study was to determine whether it is possible to quantify breast arterial calcium mass using standard digital mammography. An anthropomorphic breast phantom along with a vessel calcification phantom was imaged using a full field digital mammography system. Densitometry was used to quantify calcium mass. A calcium calibration measurement was performed at each phantom thickness and beam energy. The known (K) and measured (M) calcium mass on 5 and 9 cm thickness phantoms were related by M=0.964K-0.288 mg (r=0.997 and SEE=0.878 mg) and M=1.004K+0.324 mg (r=0.994 and SEE=1.32 mg), respectively. The results indicate that accurate calcium mass measurements can be made without correction for scatter glare as long as careful calcium calibration is made for each breast thickness. The results also indicate that composition variations and differences of approximately 1 cm between calibration phantom and breast thickness introduce only minimal error in calcium measurement. The uncertainty in magnification is expected to cause up to 5% and 15% error in calcium mass for 5 and 9 cm breast thicknesses, respectively. In conclusion, a densitometry technique for quantification of breast arterial calcium mass was validated using standard full field digital mammography. The results demonstrated the feasibility and potential utility of the densitometry technique for accurate quantification of breast arterial calcium mass using standard digital

  18. Impact of degenerative radiographic abnormalities and vertebral fractures on spinal bone density of women with osteoporosis

    Directory of Open Access Journals (Sweden)

    Lúcia Costa Paiva

    2002-01-01

    Full Text Available CONTEXT: Measurements of bone density taken by dual-energy x-ray absorptiometry are the most accurate procedure for the diagnosis of osteoporosis. This procedure has the disadvantage of measuring the density of all mineral components, including osteophytes, vascular and extra vertebral calcifications. These alterations can influence bone density results and densitometry interpretation. OBJECTIVE: To correlate radiography and densitometry findings from women with osteoporosis, analyzing the influence of degenerative processes and vertebral fractures on the evaluation of bone density. DESIGN: Retrospective study. SETTING: Osteoporosis outpatients' clinic at Hospital das Clínicas, Universidade Estadual de Campinas. PARTICIPANTS: Ninety-six postmenopausal women presenting osteoporosis diagnosed by bone density. MAIN MEASUREMENTS: Bone mineral density of the lumbar spine and femoral neck were measured by the technique of dual-energy x-ray absorptiometry, using a LUNAR-DPX densitometer. Fractures, osteophytes and aortic calcifications were evaluated by simple x-rays of the thoracic and lumbar spine. RESULTS: The x-rays confirmed vertebral fractures in 41.6%, osteophytes in 33.3% and calcifications of the aorta in 30.2%. The prevalence of fractures and aortic calcifications increased with age. The mean bone mineral density was 0.783g/cm² and the mean T-score was --3.47 DP. Neither fractures nor aortic calcifications had significant influence on bone mineral density (P = 0.36 and P = 0.09, respectively, despite the fractured vertebrae having greater bone mineral density (P < 0.02. Patients with lumbar spine osteophytes showed greater bone mineral density (P = 0.04. Osteophytosis was associated with lumbar spine bone mineral density after adjustment for fractures and aortic calcifications by multiple regression (P = 0.01. CONCLUSION: Osteophytes and lumbar spine fractures can overestimate bone density interpretation. The interpretation of densitometry

  19. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300); Intravenoese Kontrastmittel-Applikation bei aelteren Patienten - Anwendungsbeobachtung von Iopentol (Imagopaque trademark 300)

    Energy Technology Data Exchange (ETDEWEB)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D. [Zentrum fuer Klinische Radiologie, Kliniken Essen-Sued (Germany)

    2004-12-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  20. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  1. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Marchiori, Edson; Oliveira, Hugo

    2010-01-01

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  2. Accuracy of measurement of pulmonary emphysema with computed tomography: relevant points

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno, E-mail: brunohochhegger@googlemail.co [Hospital Moinhos de Vento, Porto Alegre, RS (Brazil); Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Dept. de Radiologia; Irion, Klaus L. [Liverpool Heart and Chest Hospital, Liverpool (United Kingdom); Oliveira, Hugo [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil)

    2010-07-15

    Some technical aspects should be taken into consideration in order to guarantee the reliability of the assessment of pulmonary emphysema with lung computed tomography densitometry. Changes in lung density associated with variations in lungs inspiratory and expiratory levels, computed tomography slice thickness, reconstruction algorithm and type of computed tomography apparatus make tomographic comparisons more difficult in follow-up studies of pulmonary emphysema. Nevertheless, quantitative computed tomography has replaced the visual assessment competing with pulmonary function tests as a sensitive method to measure pulmonary emphysema. The present review discusses technical variables of lung computed tomography and their influence on measurements of pulmonary emphysema. (author)

  3. Two views of functional mapping and autoradiography

    International Nuclear Information System (INIS)

    McEachron, D.L.; Adler, N.T.; Tretiak, O.J.

    1986-01-01

    This chapter is meant to serve as an initial introduction into the use and analysis of functional mapping with radiotracers and film autoradiography. The first section describes functional autoradiography from a biologist's point of view, reviewing the advantages of radiotracers for bridging the gap between behavior and neurophysiology. The physical and chemical assumptions underlying the use of radiotracers in biological systems are then examined. The second section looks at the autoradiogram from an engineering standpoint and investigates how the basic physics of radioactive decay influences the measured parameters of autoradiographs. The problems of video densitometry and the quantification of optical density and isotope concentrations are discussed

  4. Numerical Simulation of Fluid Dynamics in a Monolithic Column

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2017-01-01

    Full Text Available As for the measurement of polycyclic aromatic hydrocarbons (PAHs, ultra-performance liquid chromatography (UPLC is used for PAH identification and densitometry. However, when a solvent containing a substance to be identified passes through a column of UPLC, a dedicated high-pressure-proof device is required. Recently, a liquid chromatography instrument using a monolithic column technology has been proposed to reduce the pressure of UPLC. The present study tested five types of monolithic columns produced in experiments. To simulate the flow field, the lattice Boltzmann method (LBM was used. The velocity profile was discussed to decrease the pressure drop in the ultra-performance liquid chromatography (UPLC system.

  5. Developing radiographer roles in the context of advanced and consultant practice

    International Nuclear Information System (INIS)

    Field, Lisa J; Snaith, Beverly A

    2013-01-01

    Skill-mix initiatives have provided opportunities for radiographers to develop roles and achieve their potential, thus contributing to radiographer retention rates and increased job satisfaction. This reflective article explores two radiographic roles within an interprofessional context including the implications for confidence, competence, and future sustainability. These were reporting roles which extended into two modalities, one into bone densitometry and another into ultrasound. This article discusses how successful skill mix can benefit the individual, their department, and NHS organization and that role expansion can develop a more dynamic and resourceful workforce with transferability of skills and attributes

  6. Remote sensing of St. Augustine Decline (SAD) disease. [spectral reflectance of healthy and diseased grass

    Science.gov (United States)

    Odle, W. C.

    1976-01-01

    Laboratory and field spectral reflectance measurements of healthy and infected St. Augustine grass were made using several different instruments. Spectral differences between healthy and infected grass occured in the visible and near infrared regions. Multiband and color infrared photographs were taken of healthy and diseased turf from ground-based platforms and low altitude aircraft. Qualitative (density slicing) and quantitative (transmission densitometry) analyses revealed distinct tonal differences between healthy and St. Augustine disease (SAD) infected grass. Similar experiments are described for determining if healthy and diseased grass can be distinguished from waterstressed grass and grass deficient in either nitrogen or iron.

  7. Relationships between metacarpal morphometry, fore-arm and vertebral bone density and fractures in post-menopausal women

    International Nuclear Information System (INIS)

    Wishart, J.M.; Horowitz, M.; Bochner, M.; Need, A.G.; Nordin, B.E.C.

    1993-01-01

    The relationships between metacarpal morphometric, vertebral and forearm density measurement and the prevalence of vertebral and peripheral fractures were examined in 239 postmenopausal women (median age 63, range 32-84 years). Metacarpal cortical area/total area ratio (CA/TA) was measured with needle calipers forearm mineral density (FMD) by single photon absorptiometry and vertebral mineral density (VMD) by single energy quantitative computed tomography. The authors suggest that metacarpal morphometry, which is widely available at relatively low cost, yields cross-sectional information about bone density and fracture risk, comparable with that obtained by forearm and vertebral densitometry. (Author)

  8. Visualisation of bony and vascular structures via digital subtraction images upon the amount of anatomic background

    International Nuclear Information System (INIS)

    Hinz, A.; Scholz, A.; Zwicker, C.

    1992-01-01

    We examined the loss of contrast leaving a part of the anatomic background in digital subtraction angiography by visual analysis and densitometry. We observed a greater loss of the quality at the representation of the bone below than above an amount of anatomic background of 60%. The loss of quality at the representation of the vessels decreases more above than below an anatomical background of 45%. We think that, depending on the clinical problem, an anatomical background between 15 and 30% should be left. (orig.) [de

  9. Two-Dimensional Zymography of Proteases from Steatotic Duck Liver.

    Science.gov (United States)

    Wilkesman, Jeff; Padrón, María Fernanda; Kurz, Liliana; Rémignon, Hervé

    2017-01-01

    Protease activity present in liver cells with steatosis can be electrophoretically characterized. Zymographic techniques allow semi-quantitative results, successfully detecting cathepsin and metalloprotease activity using polyacrylamide gels copolymerized with gelatin and quantified by densitometry. By using specific inhibitors, the identity of the proteases can be confirmed. 2D zymography allows the determination of both M r. and pI of the metalloprotease and cathepsin activity present in the homogenates. The analysis of liver proteases activities in force fed ducks may elucidate the mechanisms behind steatosis development.

  10. Irradiation of parametria by double-wedge

    International Nuclear Information System (INIS)

    Weisz, Csaba; Katona, Ernoe; Zarand, Pal; Polgar, Istvan; Nemeth, Gyoergy

    1984-01-01

    The dose distribution of a cobalt unit modified with a double-wedge as well as its combination with intracavitary radiotherapy was investigated. The measurements were made in both Alderson-Rando and wather phantom by using film densitometry, thermoluminescence dosimetry and ionization chambers. The dose distribution calculated on the basis of the Van de Geij program was in good agreement with the measurements. A homogeneous irradiation of the parametria can be obtained by using a combination of intracavitary and external double-wedge irradiation. (author)

  11. Levodopa in Mucuna pruriens and its degradation

    OpenAIRE

    Haridas Pulikkalpura; Rajani Kurup; Paravanparampil Jacob Mathew; Sabulal Baby

    2015-01-01

    Mucuna pruriens is the best known natural source of L-dopa, the gold standard for treatment of Parkinsonism. M. pruriens varieties are protein rich supplements, and are used as food and fodder worldwide. Here, we report L-dopa contents in seeds of fifty six accessions of four M. pruriens varieties, M. pruriens var. pruriens, M. pruriens var. hirsuta, M. pruriens var. utilis and M. pruriens var. thekkadiensis, quantified by HPTLC-densitometry. L-dopa contents varied between 0.58 to 6.42 (%, dr...

  12. Effects of anticonvulsants and inactivity on bone disease in epileptics

    Science.gov (United States)

    Murchison, Lilian E.; Bewsher, P. D.; Chesters, Marion; Gilbert, J.; Catto, G.; Law, Elizabeth; McKay, E.; Ross, H. S.

    1975-01-01

    No significant biochemical or radiological features of vitamin D deficiency were found in groups of juvenile and adult epileptics and control groups of non-epileptic patients in hospitals for the mentally retarded. There was evidence of hepatic enzyme induction in patients on anticonvulsants, in that urinary D-glucaric acid concentration and excretion were raised. No effect was found of prolonged anticonvulsant therapy on bone densitometry, but in children immobility was closely associated with decreased bone density. The evidence suggests that disuse osteoporosis is the major bone disease in these mentally retarded children. PMID:1161672

  13. Finite Element Simulation of the Compaction and Springback of Alumix 321 PM Alloy

    Directory of Open Access Journals (Sweden)

    Stanley G. Selig

    2015-01-01

    Full Text Available A finite element simulation of the compaction and springback of an aluminum-based powder metallurgy alloy (Alumix 321 was developed and validated using the LS-DYNA hydrocode. The present work aims to directly address the current scarcity of modeling works on this popular alloy system. The Alumix 321 constitutive material parameters are presented. The model can predict the results of single-action compaction as well as the amount of springback experienced by a compact upon ejection from the die. The model has been validated using a series of experiments including powder compaction, optical densitometry, and the creation of a compaction curve.

  14. Kappa opioid receptors in rat spinal cord vary across the estrous cycle.

    Science.gov (United States)

    Chang, P C; Aicher, S A; Drake, C T

    2000-04-07

    Kappa opioid receptors (KORs) were immunocytochemically localized in the lumbosacral spinal cord of female rats in different stages of the estrous cycle to examine the influence of hormonal status on receptor density. KOR labeling was primarily in fine processes and a few neuronal cell bodies in the superficial dorsal horn and the dorsolateral funiculus. Quantitative light microscopic densitometry of the superficial dorsal horn revealed that rats in diestrus had significantly lower KOR densities than those in proestrus or estrus. This suggests that female reproductive hormones regulate spinal KOR levels, which may contribute to variations in analgesic effectiveness of KOR agonists across the estrous cycle.

  15. Developing radiographer roles in the context of advanced and consultant practice.

    Science.gov (United States)

    Field, Lisa J; Snaith, Beverly A

    2013-03-01

    Skill-mix initiatives have provided opportunities for radiographers to develop roles and achieve their potential, thus contributing to radiographer retention rates and increased job satisfaction. This reflective article explores two radiographic roles within an interprofessional context including the implications for confidence, competence, and future sustainability. These were reporting roles which extended into two modalities, one into bone densitometry and another into ultrasound. This article discusses how successful skill mix can benefit the individual, their department, and NHS organization and that role expansion can develop a more dynamic and resourceful workforce with transferability of skills and attributes.

  16. A validated HPTLC method for estimation of moxifloxacin hydrochloride in tablets.

    Science.gov (United States)

    Dhillon, Vandana; Chaudhary, Alok Kumar

    2010-10-01

    A simple HPTLC method having high accuracy, precision and reproducibility was developed for the routine estimation of moxifloxacin hydrochloride in the tablets available in market and was validated for various parameters according to ICH guidelines. moxifloxacin hydrochloride was estimated at 292 nm by densitometry using Silica gel 60 F254 as stationary phase and a premix of methylene chloride: methanol: strong ammonia solution and acetonitrile (10:10:5:10) as mobile phase. Method was found linear in a range of 9-54 nanograms with a correlation coefficient >0.99. The regression equation was: AUC = 65.57 × (Amount in nanograms) + 163 (r(2) = 0.9908).

  17. Experimental investigations of single and two-phase flow in a heated rod bundle

    International Nuclear Information System (INIS)

    Barthel, Frank; Franz, Ronald; Hampel, Uwe; Technische Univ. Dresden

    2013-01-01

    An experimental facility for the study of boiling flows in a 3 x 3 rod bundle geometry was setup. The bundle resembles in essential geometrical parts the geometry in a pressurized water reactor fuel element. The facility is operated with a refrigerant fluid. Beside standard instrumentation for temperature, pressure and flow rate we employed particle image velocimetry for single phase flow studies, gamma ray densitometry for integral gas fraction measurement sand ultrafast X-ray tomography for the study of the void dynamics in the cross-section. Moreover extensive thermo-instrumentation allows axial rod surface temperature measurements for the central heated rod. First results will be discussed in this article. (orig.)

  18. DNA Measurement of Overlapping Cell Nuclei in Thick Tissue Sections

    Directory of Open Access Journals (Sweden)

    Liang Ji

    1997-01-01

    Full Text Available The paper describes an improved image analysis procedure for measuring the DNA content of cell nuclei in thick sections of liver tissue by absorption densitometry. Whereas previous methods only permitted the analysis of isolated nuclei, the new technique enables both isolated and overlapping nuclei to be measured. A 3D segmentation procedure determines whether each object is an isolated nucleus or a pair of overlapping nuclei; in the latter case the combined optical density is redistributed to the individual nuclei. A selection procedure ensures that only complete nuclei are measured.

  19. Role of clinical indications of bone mass measurement with bi-photonic X-ray absorptiometry. Interet et indications cliniques des mesures de masse osseuse par absorptiometrie biphotonique a rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    Bone densitometry by precise, reliable and non-traumatic methods such as X-ray bi-phonon absorptiometry, is the only way to predict osteoporosis fractures risks. The whole epidemiological studies establish that bone mass loss and osteoporosis risk are directly linked. The measurement of the bone mass is the basis of osteoporosis prevention for elderly women, and of other clinical situations. This paper gives, by a critical analysis of available data, advantages and limits of bone mass measurements by X-ray bi-phonon absorptiometry, and essential clinical indications. (A.B.). 181 refs.

  20. How to simplify the analytics for input-output accountability measurements in a reprocessing plant

    International Nuclear Information System (INIS)

    Ottmar, H.; Eberle, H.; Matussek, P.; Michel-Piper, I.

    1986-02-01

    An analytical approach to high-performance uranium and plutonium accountancy measurements in reprocessing input and output solutions is presented, which provides larger operational simplicity than the conventionally applied chemical methods. The proposed alternative is based on energy-dispersive absorption edge and fluorescence X-ray spectrometry, using the proven and reliable K-edge densitometry technique as reference method. Two X-ray densitometers developed for accurate and reliable uranium and plutonium analysis in both the feed and product solutions are described. Practical experiences and results from their performance evaluation on actual process solutions from a reprocessing plant are presented and discussed. (orig.) [de

  1. Flow measurement in two-phase (gas-liquid) systems

    International Nuclear Information System (INIS)

    Hewitt, G.F.; Whalley, P.B.

    1980-01-01

    The main methods of measuring mass flow and quality in gas-liquid flows in industrial situations are reviewed. These include gamma densitometry coupled with differential pressure devices such as crifice plates, turbine flow meters and drag screens. For each method the principle of operation, and the advantages and disadvantages, are given. Some further techniques which are currently being investigated and developed for routine use are also described briefly. Finally the detailed flow measurements possible on a particular flow pattern - annular flow - is examined. (author)

  2. Nondestructive assay measurements applied to reprocessing plants

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lee, R. Stephen; Ottmar, Herbert; Guardini, Sergio

    1999-01-01

    Nondestructive assay for reprocessing plants relies on passive gamma-ray spectrometry for plutonium isotopic and plutonium mass values of medium-to-low-density samples and holdup deposits; on active x-ray fluorescence and densitometry techniques for uranium and plutonium concentrations in solutions; on calorimetry for plutonium mass in product; and passive neutron techniques for plutonium mass in spent fuel, product, and waste. This paper will describe the radiation-based nondestructive assay techniques used to perform materials accounting measurements. The paper will also discuss nondestructive assay measurements used in inspections of reprocessing plants [ru

  3. Influence of Hyperthyroidism and the State of Female Reproductive System on the Development of Osteopenic Syndrome

    Directory of Open Access Journals (Sweden)

    L.V. Herasymenko

    2015-04-01

    Full Text Available The study was focused on determining the impact of hyperthyroidism due to Graves’ disease on the state of skeletal system in women. According to the ultrasound densitometry data, pathological changes in the state of skeletal system were revealed in both reproductive age and menopause. Hyperthyroidism had especially pronounced effect on the state of skeletal system in menopausal women, who were characterized by the presence of severe osteopenia and systemic osteoporosis (75 and 25 %, respectively. These findings indicate the need for treatment of osteoporotic syndrome, which complicates Graves’ disease course in women and increases the risk of pathological fractures.

  4. Developing radiographer roles in the context of advanced and consultant practice

    Energy Technology Data Exchange (ETDEWEB)

    Field, Lisa J; Snaith, Beverly A [Radiology Department, Mid Yorkshire Hospitals NHS Trust, Pinderfields Hospital, Aberford Road, Wakefield, WF1 4DG (United Kingdom)

    2013-03-15

    Skill-mix initiatives have provided opportunities for radiographers to develop roles and achieve their potential, thus contributing to radiographer retention rates and increased job satisfaction. This reflective article explores two radiographic roles within an interprofessional context including the implications for confidence, competence, and future sustainability. These were reporting roles which extended into two modalities, one into bone densitometry and another into ultrasound. This article discusses how successful skill mix can benefit the individual, their department, and NHS organization and that role expansion can develop a more dynamic and resourceful workforce with transferability of skills and attributes.

  5. Chest X-ray and computed tomography in the evaluation of pulmonary emphysema

    International Nuclear Information System (INIS)

    Irion, Klaus Loureiro; Porto, Nelson da Silva; Santana, Pablo Rydz

    2007-01-01

    Emphysema is a condition of the lung, characterized by the abnormal increase in the size of the airspace distal to the terminal bronchioles. Currently, emphysema is the fourth leading cause of death in the USA, affecting 14 million people. The present article describes the principal tools in the imaging diagnosis of emphysema, from the early days until the present. We describe traditional techniques, such as chest X-ray, together with the evolution of computed tomography (CT) to more advanced forms, such as high resolution CT, as well as three-dimensional CT densitometry and volumetric assessment. (author)

  6. Deterioration and conservation of plasticized poly (vinyl chloride) objects

    DEFF Research Database (Denmark)

    Shashoua, Yvonne

    2002-01-01

    and after accelerated thermal ageing in various environments. Weight loss was used to quantify total loss of plasticizer. Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy was used to quantify the concentration of di (2-ethylhexyl) phthalate plasticizer (DEHP) at the surfaces...... of samples. Optical densitometry was used to quantify darkening of the PVC component of samples. Degradation of new and deteriorated PVC was inhibited by enclosing it in a non-adsorbent material, such as glass containing non-agitated air. Such storage inhibited migration and loss of DEHP....

  7. Inhibiting the deterioration of plasticized poly (vinyl chloride)-a museum perspective

    DEFF Research Database (Denmark)

    Shashoua, Yvonne

    for at least 50 years. The present study outlines a strategy for prolonging the useful lifetime of plasticized PVC objects with di-2-ethylhexyl phthalate (DEHP). Examination of deteriorated PVC in museums suggested that migration, loss and chemical breakdown of plasticizer were the major mechanisms....... Weight loss was used to quantify total loss of plasticizer. Changes in the distribution of DEHP were mapped using low-vacuum scanning electron microscopy (LV-SEM). Densitometry was used to quantify darkening of the PVC component of samples. Degradation of model formulations and naturally degraded objects...

  8. Determination of bone demineralization in cats after experimental thyrotoxicosis

    Directory of Open Access Journals (Sweden)

    Fabiano Séllos Costa

    2006-10-01

    Full Text Available Hyperthyroidism can result in serious effects on the bone metabolism in humans as well as animals. For a better characterization of thyrotoxicosis effects, 16 cats were induced into thyrotoxicosis by intaking a dose of 150 µg/kg of sodium L-thyroxine every 24 hours during 42 days. The hormonal levels were evaluated by radioimmunoassay technique and the bone mineral density of the right distal radius extremity was measured through the radiographic optical densitometry. Was verified significant bone demineralization seven days of hormonal intake as weel as radius demineralization.

  9. Raman spectroscopy of DNA-metal complexes. II. The thermal denaturation of DNA in the presence of Sr2+, Ba2+, Mg2+, Ca2+, Mn2+, Co2+, Ni2+, and Cd2+.

    OpenAIRE

    Duguid, J G; Bloomfield, V A; Benevides, J M; Thomas, G J

    1995-01-01

    Differential scanning calorimetry, laser Raman spectroscopy, optical densitometry, and pH potentiometry have been used to investigate DNA melting profiles in the presence of the chloride salts of Ba2+, Sr2+, Mg2+, Ca2+, Mn2+, Co2+, Ni2+, and Cd2+. Metal-DNA interactions have been observed for the molar ratio [M2+]/[PO2-] = 0.6 in aqueous solutions containing 5% by weight of 160 bp mononucleosomal calf thymus DNA. All of the alkaline earth metals, plus Mn2+, elevate the melting temperature of ...

  10. Fast and Convenient NIR Spectroscopy Procedure for Determination of Metformin Hydrochloride in Tablets

    Science.gov (United States)

    Pyzowski, J.; Lenartowicz, M.; Sobańska, A. W.; Brzezińska, E.

    2017-09-01

    A rapid and convenient near-infrared (NIR) reflectance spectroscopic procedure for the determination of metformin hydrochloride in tablets is presented. Determination was based on calibration curves that were obtained using a range of standards containing different concentrations of metformin hydrochloride blended with polyvinylpyrrolidone. The raw spectra of the standards, neat PVP, metformin hydrochloride, and powdered tablets were processed using a Multiplicative Scatter Correction filter as well as by the derivative spectroscopy method to give a basis for the calibration curve construction. The results were validated by thin-layer chromatography followed by UV-densitometry.

  11. Digital image processing in the nuclear field with ImaWin 5.0

    International Nuclear Information System (INIS)

    Marajofsky, A.; Trafelati, A.A.; Lavagnino, C.E.

    2000-01-01

    ImaWin is a software project designed to cover a broad set of applications of Digital Image Processing in the Nuclear Field. Since 1994 the system has evolved in a complete tool that helped to face problems like densitometry calculus, quality control in pellets, deposit administration and surveillance. Neural network kernel and ImaScript scripting language are included within the package. The open and incremental development of ImaWin software has been allowing easy expansion upon a common re-engineering framework. (author)

  12. Foveal cone spacing and cone photopigment density difference: objective measurements in the same subjects.

    Science.gov (United States)

    Marcos, S; Tornow, R P; Elsner, A E; Navarro, R

    1997-07-01

    Foveal cone spacing was measured in vivo using an objective technique: ocular speckle interferometry. Cone packing density was computed from cone spacing data. Foveal cone photopigment density difference was measured in the same subjects using retinal densitometry with a scanning laser ophthalmoscope. Both the cone packing density and cone photopigment density difference decreased sharply with increasing retinal eccentricity. From the comparison of both sets of measurements, the computed amounts of photopigment per cone increased slightly with increasing retinal eccentricity. Consistent with previous results, decreases in cone outer segment length are over-compensated by an increase in the outer segment area, at least in retinal eccentricities up to 1 deg.

  13. Overview and outlook on muon survey tomography based on micromegas detectors for unreachable sites technology

    Directory of Open Access Journals (Sweden)

    Roche I. Lázaro

    2016-01-01

    Full Text Available The present document describes the functioning principles of the Muon Survey Tomography based on Micromegas detectors for Unreachable Sites Technology and its distinguishing features from other Micromegas-like detectors. Additionally, it addresses the challenges found while operating the first generation and the resulting improvements. Currently, the project Temporal Tomography of the Densitometry by the Measurement of Muons is focused on obtaining a reliable pulse from the micromesh, associated to the passing of a muon, in order to trigger the acquisition and operate in standalone mode. An outlook of the future steps of the project is provided as well.

  14. Radiological diagnosis of osteoporosis

    International Nuclear Information System (INIS)

    Heuck, F.H.W.

    1990-01-01

    The roentgen-morphologic findings of 'osteoporosis' in the different regions of the skeleton are demonstrated. A combination of osteoporosis and osteomalacia induced by hormonal and metabolic bone diseases occur frequently. The results of sequential studies are discussed. Diagnostic informations obtained by quantitative radiology, especially by different methods like x-ray morphometry, densitometry with gamma-rays of isotopes of different energies, quantitative computed tomography, and imaging analysis with electronic methods are described. The sequential use of diagnostic imaging techniques in cases of suspected osteoporosis are explained. (Author)

  15. Colour thresholding and objective quantification in bioimaging

    Science.gov (United States)

    Fermin, C. D.; Gerber, M. A.; Torre-Bueno, J. R.

    1992-01-01

    Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

  16. Quantification of Emphysema with a Three-Dimensional Chest CT Scan: Correlation with the Visual Emphysema Scoring on Chest CT, Pulmonary Function Tests and Dyspnea Severity

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Jeong; Hwang, Jung Hwa [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2011-09-15

    We wanted to prospectively evaluate the correlation between the quantification of emphysema using 3D CT densitometry with the visual emphysema score, pulmonary function tests (PFT) and the dyspnea score in patients with chronic obstructive pulmonary disease (COPD). Non-enhanced chest CT with 3D reconstruction was performed in 28 men with COPD (age 54-88 years). With histogram analysis, the total lung volume, mean lung density and proportion of low attenuation lung volume below predetermined thresholds were measured. The CT parameters were compared with the visual emphysema score, the PFT and the dyspnea score. A low attenuation lung volume below -950 HU was well correlated with the DLco and FEV{sub 1}/FVC. A Low attenuation lung volume below -950 HU and -930 HU was correlated with visual the emphysema score. A low attenuation lung volume below -950 HU was correlated with the dyspnea score, although the correlations between the other CT parameters and the dyspnea score were not significant. Objective quantification of emphysema using 3D CT densitometry was correlated with the visual emphysema score. A low attenuation lung volume below -950 HU was correlated with the DLco, the FEV{sub 1}/FVC and the dyspnea score.

  17. [In vitro study with techniques of imaging of the composition of urinary calculi].

    Science.gov (United States)

    Tellez Martínez-Fornés, M; Burgos Revilla, F J; Sáez Garrido, J C; Soria Descalzo, J; Barbero González, J; Sánchez Corral, J; Minaya Minaya, A; Vallejo Herrador, J

    1997-02-01

    Pre-treatment knowledge of the lithiasic composition can be useful to design the most appropriate therapeutic scheme for each kind of stone. The relationship between the stone's densitometry information provided by the different imaging techniques, conventional radiology (RX), computerized axial tomography (CAT) and dual energy radiographic densitometry (DO) is analyzed, as well as the elemental composition determined by the microanalysis of fragments obtained post-lithotrity using a scanning electronic microscope (SEM) associated to X-ray dispersion energy (XDE). 60 stones, 12 for each pure composition selected (calcium oxalate mono and dihydro, phosphocarbonate, magnesium ammonium phosphate and uric acid), were studied with XR, CAT and DO and were later subjected to lithofragmentation in vitro. Fragments analysis was carried out post-lithotrity with SEM associated to XDE. The X-ray does not allow to establish the composition of some calculi. CAT quantifies the mineral contents of the oxalocalcic and infective calculi and differentiates the uric acid from the other compositions because the mean density values are under 500 Hounsfield Units. DO evaluates the lithiasic content in phosphocarbonate salts which are structurally similar to bone hydroxyapatite.

  18. Determination of Flavonoids, Phenolic Acids, and Xanthines in Mate Tea (Ilex paraguariensis St.-Hil.

    Directory of Open Access Journals (Sweden)

    Mirza Bojić

    2013-01-01

    Full Text Available Raw material, different formulations of foods, and dietary supplements of mate demands control of the content of bioactive substances for which high performance thin layer chromatography (TLC, described here, presents simple and rapid approach for detections as well as quantification. Using TLC densitometry, the following bioactive compounds were identified and quantified: chlorogenic acid (2.1 mg/g, caffeic acid (1.5 mg/g, rutin (5.2 mg/g, quercetin (2.2 mg/g, and kaempferol (4.5 mg/g. The results obtained with TLC densitometry for caffeine (5.4 mg/g and theobromine (2.7 mg/g show no statistical difference to the content of total xanthines (7.6 mg/g obtained by UV-Vis spectrophotometry. Thus, TLC remains a technique of choice for simple and rapid analysis of great number of samples as well as a primary screening technique in plant analysis.

  19. [Digitalization of histological images as a method of quantifying the demyelinating process].

    Science.gov (United States)

    Stojiljković, G; Tasić, M; Budakov, B

    1996-01-01

    The basic aim of this paper was to check the hypothesis whether after head trauma the brain tissue looses myelinic membrane which surrounds the axon, and if this possibly established loss can be quantified, that is if it is possible to determine the degree of disintegration. One of the aims was to examine this method itself. The gathered results show that both the hypothesis and the aims were justified. It has been established that the diffuse axonal lesion in the examined samples reflects in a loss of axon's myelinic membrane. The loss was 50% greater in the test group in regard to the control group. To digitalize histologic pictures we have used Laser Scanner Densitometry Station and software by Biomed. In regard to medical jurisprudence, the laser scanner densitometry offers more relevant data in cases apparently unclear and in sudden deaths after head injuries. Application of this method and further investigations will be directed to further attempts to clear up connections between the mechanism of injury and degree of biologic response of the brain tissue.

  20. Use of Competitive PCR to Detect and Quantify Haplosporidium nelsoni Infection (MSX disease) in the Eastern Oyster (Crassostrea virginica).

    Science.gov (United States)

    Day, J Michael; Franklin, Dean E.; Brown, Bonnie L.

    2000-09-01

    This study was undertaken to develop a quantitative polymerase chain reaction assay that would improve the utility of PCR for detecting Haplosporidium nelsoni (MSX), a serious parasite of the eastern oyster Crassostrea virginica. A competitive PCR sequence was generated from the H. nelsoni small subunit ribosomal DNA fragment, originally described by Stokes and colleagues, that was amplified by the same PCR primers and had similar amplification performance. Assays performed using competitor dilutions ranging from 0.05 to 500 pg/µl DNA were used to test oyster samples designated using histological techniques as having "light" or "heavy" MSX infections. Visual diagnoses were confirmed equally well with three methods: densitometry of ethidium-bromide-stained agarose, densitometry of SYBRGreen-stained polyacrylamide gels, and analysis by GeneScan 3.0 of fluorescent products detected in ultrathin gels. Oysters diagnosed as negative for MSX tested as negative or light by PCR. Oysters with light MSX infections generally had less than 5 pg/µl infectious DNA. Oysters with heavy infections generally corresponded to 5 pg/µl or greater competitor dilutions.

  1. Quality control of nuclear fuel plates using digital image processing techniques

    International Nuclear Information System (INIS)

    Salinas, Renato; Radd, Ulrich; Coronado, Harold; Olivares, Luis

    2003-01-01

    The Chilean Atomic Energy Commission (CCHEN) has developed the technology requires to manufacture low enriched uranium-235 nuclear fuel elements used in non-power reactor applications and in research. These fuel plates are assembled in two nuclear facilities located at La Reina (RECH-1) and Lo Aguirre where the present work was developed. Furthermore since high quality standards have been met, these facilities are able to export these nuclear fuel plates to foreign countries. Each MTR fuel elements consists of 16 low enriched uranium silicide (U 3 Si 2 ) fuel plates. A stringent quality assurance program requires among others, homogeneity measurements of uranium surface density values of these fuel plates, which are traditionally accomplished with optical densitometry methods. We have implemented and alternative technique which uses computer vision to determine uranium surface density values in these fuel plates. Both techniques are compared. Advantages of machine vision methods include considerable time saving and a complete quantitative evaluation of uranium densities as compared to the sparse technique involved in the optical densitometry method (Au)

  2. Hardware and software design considerations in engineering an image processing workstation

    International Nuclear Information System (INIS)

    Feingold, E.; Seshadri, S.B.; Tretiak, O.J.

    1986-01-01

    The use of densitometry in autoradiography is not novel, but computer-assisted video densitometry is gaining increasing popularity. This is because functional mapping with radionuclides, such as the 2-deoxyglucose (2-DG) technique, produces enormous numbers of images which require quite detailed analysis and quantification. Effective use of the data contained in 2-DG autoradiograms is almost unfeasible if computer assisted image analysis is not utilized, and a video densitometric system (one that uses a television camera to scan the autoradiogram) is both suitable and economical. This paper will describe the software and hardware design and implementation of one such image analysis system: the DUMAs system and the BRAIN software package. This chapter describes the results of the authors' development effort. Since the user interface is paramount, the next section describes the BRAIN software. In the following section, they describe the issues relevant to selecting the DUMAS hardware and some of the alternatives considered. In the concluding section, they summarize the status of the DUMAS/BRAIN project and look at future developments

  3. Quantification of Emphysema with a Three-Dimensional Chest CT Scan: Correlation with the Visual Emphysema Scoring on Chest CT, Pulmonary Function Tests and Dyspnea Severity

    International Nuclear Information System (INIS)

    Park, Hyun Jeong; Hwang, Jung Hwa

    2011-01-01

    We wanted to prospectively evaluate the correlation between the quantification of emphysema using 3D CT densitometry with the visual emphysema score, pulmonary function tests (PFT) and the dyspnea score in patients with chronic obstructive pulmonary disease (COPD). Non-enhanced chest CT with 3D reconstruction was performed in 28 men with COPD (age 54-88 years). With histogram analysis, the total lung volume, mean lung density and proportion of low attenuation lung volume below predetermined thresholds were measured. The CT parameters were compared with the visual emphysema score, the PFT and the dyspnea score. A low attenuation lung volume below -950 HU was well correlated with the DLco and FEV 1 /FVC. A Low attenuation lung volume below -950 HU and -930 HU was correlated with visual the emphysema score. A low attenuation lung volume below -950 HU was correlated with the dyspnea score, although the correlations between the other CT parameters and the dyspnea score were not significant. Objective quantification of emphysema using 3D CT densitometry was correlated with the visual emphysema score. A low attenuation lung volume below -950 HU was correlated with the DLco, the FEV 1 /FVC and the dyspnea score.

  4. Low-level dosimetry based on activation analysis of badge film, 1

    International Nuclear Information System (INIS)

    Morikawa, Kaoru; Yamashita, Kazuya; Inamoto, Kazuo; Maeda, Masayuki; Sato, Takashi; Ono, Koichi.

    1988-01-01

    Underexposed badge film contains a minor quantity of silver which corresponds to the low radiation dose even after completion of the photographic densitometry ; however, it cannot be detected with a photographic densitometer. We intended to clarify the minor silver content based on radioactivation analysis with thermal neutrons at KUR (Kyoto University Research Reactor). The natural silver consists of two stable nuclides, i.e., 107 Ag and 109 Ag. These can be activated with irradiation of thermal neutrons to two radionuclides, i.e., 108 Ag and 110 Ag. In this paper, through the activation analysis of an underexposed badge film, methods of measurements are shown regarding both 108 Ag produced by the 107 Ag (n, γ) reaction and 110 Ag by the 109 Ag (n, γ). After underexposed badge films were irradiated with thermal neutrons, some gamma-rays emitted from the radionuclides in the activated films were measured with a high pure Ge detector or a NaI (Tl) scintillation detector. The following results were obtained: (1) several elements such as silver, iodine, gold, antimony, manganese and copper were detected by activation analyses of films exposed to low level 60 Co gamma-rays, (2) the exposure vs 108 Ag or 110 Ag activity curve was linear in the lower dose range of 60 Co gamma-rays. These data indicate that low level radiation doses, which is indeterminable by ordinary photographic densitometry, can be estimated by activation analysis of silver atoms in badge films. (author)

  5. Performance of X-ray absorptiometry in post-menopausal vertebral osteoporosis. Discriminant value of vertebral and femoral measurements, fracture threshold, reproducibility. Performances de l'absorptiometrie a rayons X dans l'osteoporose vertebrale post-menopausique

    Energy Technology Data Exchange (ETDEWEB)

    Pouilles, J.M.; Tremollieres, F.; Ribot, C. (Hopital Purpan, 31 - Toulouse (FR))

    1990-12-01

    The aim of this study was to assess the performance of a new bone densitometry technique, X-ray absorptiometry, in vertebral osteoporosis with fracture(s). Vertebral and femoral (neck, Ward's triangle and trochanter) bone density was measured in 60 women with at least one vertebral compression fracture of osteoporotic origin (mean age: 61), 100 controls of the same age and in 40 young adults (mean age: 30). Osteoporosis patients had significantly (p<0.0005) low bone density values in comparison with the young adults. Measurements using the spine and Ward's triangle had the best discriminant values assessed by the ROC (Receiver Operating Characteristics) technique (areas under the curve: 95% and 84% respectively). The fracture threshold was fixed at a vertebral bone density of 0.78 g/cm{sup 2}, this value giving the best compromise between sensitivity (83%) and specificity (95%) with 91% of subjects appropriately classifed. Reproducibility was assessed in the short term in 9 osteoporosis patients. The mean standard deviation of measurements was 0.017 g/cm{sup 2} (coefficient of variation: 2.6%) as compared with 0.010 g/cm{sup 2} (coefficient of variation: 0.8%) in the young adult. These results emphasise the true advance represented by X-ray absorptiometry in the area of bone densitometry, notably in the assessment and monitoring of demineralisation disorders.

  6. Outcomes of bone density measurements in coeliac disease.

    Science.gov (United States)

    Bolland, Mark J; Grey, Andrew; Rowbotham, David S

    2016-01-29

    Some guidelines recommend that patients with newly diagnosed coeliac disease undergo bone density scanning. We assessed the bone density results in a cohort of patients with coeliac disease. We searched bone density reports over two 5-year periods in all patients from Auckland District Health Board (2008-12) and in patients under 65 years from Counties Manukau District Health Board (2009-13) for the term 'coeliac.' Reports for 137 adults listed coeliac disease as an indication for bone densitometry. The average age was 47 years, body mass index (BMI) 25 kg/m(2), and 77% were female. The median time between coeliac disease diagnosis and bone densitometry was 261 days. The average bone density Z-score was slightly lower than expected (Z-score -0.3 to 0.4) at the lumbar spine, total hip and femoral neck, but 88-93% of Z-scores at each site lay within the normal range. Low bone density was strongly related to BMI: the proportions with Z-score 30 kg/m(2) were 28%, 15%, 6% and 0% respectively. Average bone density was normal, suggesting that bone density measurement is not indicated routinely in coeliac disease, but could be considered on a case-by-case basis for individuals with strong risk factors for fracture.

  7. Effects of Chronic Exposure to Sodium Arsenite on Expressions of VEGF and VEGFR2 Proteins in the Epididymis of Rats

    Directory of Open Access Journals (Sweden)

    Dai Yan-Ping

    2017-01-01

    Full Text Available Objective. To study the expressions of VEGF and VEGFR2 at protein level in the epididymis of rats with arsenism. Methods. Forty male Sprague-Dawley rats were randomly divided into four groups: the high dose arsenic infected group (60.0 mg/L in water, the middle dose arsenic infected group (12.0 mg/L in water, the low dose arsenic infected group (2.4 mg/L in water, and the control group (distilled water. Rats were treated with arsenic through drinking water for 6 consecutive months. At the end of the experiment, the average densitometry values of apoptotic cells in epididymis tubules were determined by TUNEL method; the protein and mRNA levels of VEGF and VEGFR2 were observed by immunohistochemistry, Western blot, and real time fluorescent quantitative PCR, respectively. Results. Compared with the control group, in each infected group, the average densitometry values of apoptotic cells in the epididymis tubules were significantly lower. Compared with control group, protein and mRNA levels of VEGF and VEGFR2 in each infected group were obviously declined. The correlations between protein and mRNA levels of VEGF and VEGFR2 were positively exhibited (r = 0.843, 0.869, p < 0.05. Conclusions. Arsenism affects the expressions of VEGF and VEGFR2 in the epididymis of rats and results in apoptosis of pathophysiology of male infertility.

  8. [Transversal study on the prevalence of Metabolic Bone Disease (MBD) and Home Parenteral Nutrition (HPN) in Spain: data from NADYA group].

    Science.gov (United States)

    Martínez, C; Virgili, N; Cuerda, C; Chicharro, L; Gómez, P; Moreno, J M; Álvarez, J; Martí, E; Matía, P; Penacho, M A; Garde, C; De Luis, D; Gonzalo, M; Lobo, G

    2010-01-01

    Patients with intestinal failure who receive HPN are at high risk of developing MBD. The origin of this bone alteration is multifactorial and depends greatly on the underlying disease for which the nutritional support is required. Data on the prevalence of this disease in our environment is lacking, so NADYA-SEMPE group has sponsored this transversal study with the aim of knowing the actual MBD prevalence. Retrospective data from 51 patients from 13 hospitals were collected. The questionnaire included demographic data as well as the most clinically relevant for MBD data. Laboratory data (calciuria, PTH, 25 -OH -vitamin D) and the results from the first and last bone densitometry were also registered. Bone mineral density had only been assessed by densitometry in 21 patients at the moment HPN was started. Bone quality is already altered before HPN in a significant percentage of cases (52%). After a mean follow up of 6 years, this percentage increases up to 81%. Due to retrospective nature of the study and the low number of subjects included it has not been possible to determine the role that HPN plays in MBD etiology. Only 35% of patients have vitamin D levels above the recommended limits and the majority of them is not on specific supplementation. HPN is associated with very high risk of MBD, therefore, management protocols that can lead to early detection of the problem as well as guiding for follow up and treatment of these patients are needed.

  9. Comparative functional investigations of the lungs in children suffering from mucoviscidosis

    International Nuclear Information System (INIS)

    Lorenz, R.

    1978-01-01

    22 children suffering from mucoviscidosis - 15 boys and 7 girls-, aged between 1 and 12 years, were examined twice in a period of 8 months. In nearly all children older than 5 years, vital capacity, one-second values, resistance, intrathoracic gas volume, and strength of the hands could be determined. The thorax was X-rayed in ap and lateral radiation direction, and the pictures were analyzed by two experts (Schuster and Lorenz) according to the score set up by Chrispin and Norman. Using a 10Ci 137 Cs source, 8 measuring volumes of a few cm 3 each were investigated densitometrically (principle: measurement of Compton backscattering) during inhalation and exhalation, thus obtaining a picture of their role in ventilation. From unpublished data material, standard values of lung density were determined in dependence of age, sex, and measuring volume. Variations were high, especially in the youngest age group. The densitometric findings were correlated with other results (score of anamnetic findings, strength of the two hands, vital capacities, IGV, resistance of the respiratory tract, one-second value, Chrispin-Norman score). A correlation at 1% level was found between one-second value (sample: 6; coefficient of correlation: 0.8624) and densitometry as well as between the score of the anamnetic findings (sample: 22; coefficient of correlation: -0.5681) and densitometry. There were no significant correlations in the rest of the cases. Radiation exposure is low. (orig./AJ) 891 AJ/orig.- 892 MKO [de

  10. Variation in sensitivity, absorption and density of the central rod distribution with eccentricity.

    Science.gov (United States)

    Tornow, R P; Stilling, R

    1998-01-01

    To assess the human rod photopigment distribution and sensitivity with high spatial resolution within the central +/-15 degrees and to compare the results of pigment absorption, sensitivity and rod density distribution (number of rods per square degree). Rod photopigment density distribution was measured with imaging densitometry using a modified Rodenstock scanning laser ophthalmoscope. Dark-adapted sensitivity profiles were measured with green stimuli (17' arc diameter, 1 degrees spacing) using a T ubingen manual perimeter. Sensitivity profiles were plotted on a linear scale and rod photopigment optical density distribution profiles were converted to absorption profiles of the rod photopigment layer. Both the absorption profile of the rod photopigment and the linear sensitivity profile for green stimuli show a minimum at the foveal center and increase steeply with eccentricity. The variation with eccentricity corresponds to the rod density distribution. Rod photopigment absorption profiles, retinal sensitivity profiles, and the rod density distribution are linearly related within the central +/-15 degrees. This is in agreement with theoretical considerations. Both methods, imaging retinal densitometry using a scanning laser ophthalmoscope and dark-adapted perimetry with small green stimuli, are useful for assessing the central rod distribution and sensitivity. However, at present, both methods have limitations. Suggestions for improving the reliability of both methods are given.

  11. Influences of transplantation on metabolic bone diseases in dialysis patients. Measurement of bone density with multiple X-ray photodensitometry

    International Nuclear Information System (INIS)

    Hida, Miho

    1994-01-01

    Renal osteodystrophy is a grave complication in dialysis patients. In this study, we evaluated the effect of renal transplantation (Txp) on metabolic bone diseases in renal transplant recipients (RTR), by multiple scanning X-ray photodensitometry (MD/MS). In only about 10% of RTR, bone metabolism recovered following improvement of renal function 1-2 years after Txp. Most cases showed decreased ΣGS and μ' scores on the MD/MS 1-2 years after Txp. Then ΣGS and μ' gradually increased over a long period. In seven of ten RTR with long-term graft survival (10 years<), ΣGS and μ' scores were within normal limits and densitometry bone patterns were normal. In four of five cases that received ciclosporin and had undergone Txp more than five years before, densitometry bone patterns were normal. Treatment with high doses of steroids due to acute rejection caused a sharp decline of ΣGS and μ' scores. In FK506-medicated RTR, ΣGS and μ' scores 1-2 years after Txp were decreased. In a 21-year-old female patient who had undergone Txp as the age of 13-year-old, there was little bone growth and ΣGS and μ' scores were significantly decreased. (author)

  12. Void fraction prediction in two-phase flows independent of the liquid phase density changes

    International Nuclear Information System (INIS)

    Nazemi, E.; Feghhi, S.A.H.; Roshani, G.H.

    2014-01-01

    Gamma-ray densitometry is a frequently used non-invasive method to determine void fraction in two-phase gas liquid pipe flows. Performance of flow meters using gamma-ray attenuation depends strongly on the fluid properties. Variations of the fluid properties such as density in situations where temperature and pressure fluctuate would cause significant errors in determination of the void fraction in two-phase flows. A conventional solution overcoming such an obstacle is periodical recalibration which is a difficult task. This paper presents a method based on dual modality densitometry using Artificial Neural Network (ANN), which offers the advantage of measuring the void fraction independent of the liquid phase changes. An experimental setup was implemented to generate the required input data for training the network. ANNs were trained on the registered counts of the transmission and scattering detectors in different liquid phase densities and void fractions. Void fractions were predicted by ANNs with mean relative error of less than 0.45% in density variations range of 0.735 up to 0.98 gcm −3 . Applying this method would improve the performance of two-phase flow meters and eliminates the necessity of periodical recalibration. - Highlights: • Void fraction was predicted independent of density changes. • Recorded counts of detectors/void fraction were used as inputs/output of ANN. • ANN eliminated necessity of recalibration in changeable density of two-phase flows

  13. [Normocalcemic primary hyperparathyroidism].

    Science.gov (United States)

    Spivacow, Francisco R; Sapag Durán, Ana; Zanchetta, María B

    2014-01-01

    This report shows our conclusions on the clinical, biochemical and densitometry characteristics of 35 normocalcemic primary hyperparathyroidism (PHPT) patients. This condition is defined by a high level of intact parathyroid hormone (iPTHI) with persistently normal serum and ionized calcium in the absence of secondary hyperparathyroidism. Our selection consisted of 30 women (90%) and 5 men (10%). The control group of 55 hypercalcemic patients with primary hyperparathyroidism included 51 women (93%) and 4 men (7%). The average age at diagnosis of normocalcemic PHPT was 61.4 ± 11.7 years and 56.4 ± 11.3 years in hypercalcemic PHPT. Besides the expected differences in serum calcium, ionized calcium, phosphorus and 24 h urinary calcium, we found no significant changes in other biochemical variables, and no differences in densitometry evaluations such as the presence of osteopenia or osteoporosis and the number of fractures in the two types of PHPT. But there was a significant difference in the presence of renal lithiasis between normocalcemic PHPT (11.4%) and clasic PHPT (49.1%) p < 0.0005, to some extent associated to the presence of hypercalciuria in classic PHPT. Two of the 35 patients with normocalcemic PHPT became classic hypercalcemic PHPT over a 4 year follow-up period. Our findings support the hypothesis that the normocalcemic PHPT could be an early stage of the classic PHPT, both having similar clinical effects to metabolic renal and bone levels.

  14. Validated electrochemical and chromatographic quantifications of some antibiotic residues in pharmaceutical industrial waste water.

    Science.gov (United States)

    Ibrahim, Heba K; Abdel-Moety, Mona M; Abdel-Gawad, Sherif A; Al-Ghobashy, Medhat A; Kawy, Mohamed Abdel

    2017-03-01

    Realistic implementation of ion selective electrodes (ISEs) into environmental monitoring programs has always been a challenging task. This could be largely attributed to difficulties in validation of ISE assay results. In this study, the electrochemical response of amoxicillin trihydrate (AMX), ciprofloxacin hydrochloride (CPLX), trimethoprim (TMP), and norfloxacin (NFLX) was studied by the fabrication of sensitive membrane electrodes belonging to two types of ISEs, which are polyvinyl chloride (PVC) membrane electrodes and glassy carbon (GC) electrodes. Linear response for the membrane electrodes was in the concentration range of 10 -5 -10 -2  mol/L. For the PVC membrane electrodes, Nernstian slopes of 55.1, 56.5, 56.5, and 54.0 mV/decade were achieved over a pH 4-8 for AMX, CPLX, and NFLX, respectively, and pH 3-6 for TMP. On the other hand, for GC electrodes, Nernstian slopes of 59.1, 58.2, 57.0, and 58.2 mV/decade were achieved over pH 4-8 for AMX, CPLX, and NFLX, respectively, and pH 3-6 for TMP. In addition to assay validation to international industry standards, the fabricated electrodes were also cross-validated relative to conventional separation techniques; high performance liquid chromatography (HPLC), and thin layer chromatography (TLC)-densitometry. The HPLC assay was applied in concentration range of 0.5-10.0 μg/mL, for all target analytes. The TLC-densitometry was adopted over a concentration range of 0.3-1.0 μg/band, for AMX, and 0.1-0.9 μg/band, for CPLX, NFLX, and TMP. The proposed techniques were successfully applied for quantification of the selected drugs either in pure form or waste water samples obtained from pharmaceutical plants. The actual waste water samples were subjected to solid phase extraction (SPE) for pretreatment prior to the application of chromatographic techniques (HPLC and TLC-densitometry). On the other hand, the fabricated electrodes were successfully applied for quantification of the antibiotic residues in actual

  15. The Relevance of Osteoclastic and Osteoblastic Activity Markers Follow-Up in Patients on Antiresorptive Osteoporosis Treatment.

    Science.gov (United States)

    Smilic, Tanja N; Novakovic, Tatjana R; Markovic-Jovanovic, Snezana R; Smilic, Ljiljana L J; Mitic, Javorka S; Radunovic, Miodrag L

    2017-11-02

    In general, markers of bone formation and markers of bone resorption are changing synergistically, so the monitoring of any osteoclastic and any osteoblastic marker should reflect the rate of bone transformation. The aim of the study is to monitor the bone metabolism markers in postmenopausal women with osteoporosis and osteopenia along with the variations caused by the effects of bisphosphonate therapy. The study involved 55 women of average age of 57.95 years, with osteopenia or osteoporosis. The patients with osteoporosis were treated with bisphosphonates (75 mg once a week); the laboratory tests were performed before the treatment and 6 months later. Patients with osteopenia were evaluated at the first assessment and 6 months later. The tests included bone densitometry, dual-energy X-ray absorptiometry, osteocalcin, alkaline phosphatase, collagen 1 N-terminal pro-peptide (P1NP), and beta C telopeptide of type I collagen (CTX). The mean T-score was -2.80 ± 0.63 before therapy and -2.64 ± 0.45 6 months later (p < 0.001). Women with osteoporosis had elevated levels of osteocalcin and P1NP at the first assessment, whereas the alkaline phosphatase level did not change with the treatment. After the introduction of antiresorptive therapy, the levels of osteocalcin and P1NP significantly decreased (p < 0.001). In the group with osteopenia, the biochemical markers activity were increased in both assessments. In patients with osteoporosis, Beta-CTX was increased in the first evaluation, and decreased after treatment (p = 0.001). The results indicate that the assessment of biochemical markers of bone metabolism show excellent results in the assessment of prognosis, monitoring the course and the response to various treatment regimens of osteoporosis and evince strong correlation with standard densitometry and dual-energy X-ray absorptiometry procedures. P1NP and CTX show better diagnostic applicability compared with osteocalcin and alkaline phosphatase

  16. Ethnic Differences in Bone Health

    Directory of Open Access Journals (Sweden)

    Ayse eZengin

    2015-03-01

    Full Text Available There are differences in bone health between ethnic groups in both men and in women. Variations in body size and composition are likely to contribute to reported differences. Most studies report ethnic differences in areal bone mineral density (aBMD which do not consistently parallel ethnic patterns in fracture rates. This suggests that other parameters beside aBMD should be considered when determining fracture risk between and within populations, including other aspects of bone strength: bone structure and microarchitecture as well muscle strength (mass, force generation, anatomy and fat mass. We review what is known about differences in bone-densitometry derived outcomes between ethnic groups and the extent to which they account for the differences in fracture risk. Studies are included that were published primarily between 1994 – 2014. A ‘one size fits all approach’ should not be used to understand better ethnic differences in fracture risk.

  17. Radiology of osteoporosis

    International Nuclear Information System (INIS)

    Grampp, S.

    2008-01-01

    This second edition of Radiology of Osteoporosis has been fully updated so as to represent the current state of the art. It provides a comprehensive overview of osteoporosis, the pathologic conditions that give rise to osteoporosis, and the complications that are frequently encountered. After initial chapters devoted to pathophysiology, the presentation of osteoporosis on conventional radiographs is illustrated and discussed. Thereafter, detailed consideration is given to each of the measurement methods employed to evaluate osteoporosis, including dual x-ray absorptiometry, vertebral morphometry, spinal and peripheral quantitative computed tomography, quantitative ultrasound, and magnetic resonance imaging. The role of densitometry in daily clinical practice is appraised. Finally, a collection of difficult cases involving pitfalls is presented, with guidance to their solution. The information contained in this volume will be invaluable to all with an interest in osteoporosis. (orig.)

  18. Quantifying emphysema extent from weakly labeled CT scans of the lungs using label proportions learning

    DEFF Research Database (Denmark)

    Ørting, Silas Nyboe; Petersen, Jens; Wille, Mathilde

    2016-01-01

    Quantification of emphysema extent is important in diagnosing and monitoring patients with chronic obstructive pulmonary disease (COPD). Several studies have shown that emphysema quantification by supervised texture classification is more robust and accurate than traditional densitometry. Current...... techniques require highly time consuming manual annotations of patches or use only weak labels indicating overall disease status (e.g, COPD or healthy). We show how visual scoring of regional emphysema extent can be exploited in a learning with label proportions (LLP) framework to both predict presence...... of emphysema in smaller patches and estimate regional extent. We evaluate performance on 195 visually scored CT scans and achieve an intraclass correlation of 0.72 (0.65–0.78) between predicted region extent and expert raters. To our knowledge this is the first time that LLP methods have been applied...

  19. Volume adjustment of lung density by computed tomography scans in patients with emphysema

    DEFF Research Database (Denmark)

    Shaker, S B; Dirksen, A; Laursen, Lars Christian

    2004-01-01

    of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. RESULTS: The coefficients for volume adjustment for PD were...... relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. CONCLUSION: Volume adjustment is mandatory in repeated CT densitometry......PURPOSE: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. MATERIAL AND METHODS: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software...

  20. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  1. Predicting vertebral bone strength by vertebral static histomorphometry

    DEFF Research Database (Denmark)

    Thomsen, Jesper Skovhus; Ebbesen, Ebbe Nils; Mosekilde, Lis

    2002-01-01

    of the entire vertebral bodies (L-2) were used for histomorphometry. The other iliac crest biopsies and the L-3 were destructively tested by compression. High correlation was found between BV/TV or Tb.Sp and vertebral bone strength (absolute value of r = 0.86 in both cases). Addition of Tb.Th significantly....... No gender-related differences were found in any of the relationships. Neither static histomorphometry nor biomechanical testing of iliac crest bone biopsies is a good predictor of vertebral bone strength.......The study investigates the relationship between static histomorphometry and bone strength of human lumbar vertebral bone. The ability of vertebral histomorphometry to predict vertebral bone strength was compared with that of vertebral densitometry, and also with histomorphometry and bone strength...

  2. Thailand: fertile ground for nuclear technology

    International Nuclear Information System (INIS)

    Innes, R.

    1990-01-01

    Thailand's Office of Atomic Energy for Peace (OAEP) is bringing the benefits of food irradiation and nuclear-based agricultural techniques to the population. One of the most successful OAEP programs involves irradiating a popular Thai delicacy, 'nham' (fermented raw pork) which is otherwise often contaminated with salmonella, and sometimes with trichinella. Irradiated nham has proven popular with Thai consumers. Other nuclear techniques are being applied as follows: neutron densitometry and isotope tracer techniques are providing a better understanding of the relationships between soil, fertilizer and plants; radioimmunoassay of progesterone is improving breeding of cattle and buffaloes; seed irradiation is producing improved varieties of plants; irradiation is being used to sterilize control fruit flies

  3. Packing properties 1-alkanols and alkanes in a phospholipid membrane

    DEFF Research Database (Denmark)

    Westh, Peter

    2006-01-01

    We have used vibrating tube densitometry to investigate the packing properties of four alkanes and a homologous series of ten alcohols in fluid-phase membranes of dimyristoyl phosphatidylcholine (DMPC). It was found that the volume change of transferring these compounds from their pure states int...... into the membrane core, which is loosely packed. In this region, they partially occupy interstitial (or free-) volume, which bring about a denser molecular packing and generate a negative contribution to Vm(puremem)....... into the membrane, Vm(puremem), was positive for small (C4-C6) 1-alkanols while it was negative for larger alcohols and all alkanes. The magnitude of Vm(puremem) ranged from about +4 cm3/mol for alcohols with an alkyl chain about half the length of the fatty acids of DMPC, to -10 to -15 cm3/mol for the alkanes...

  4. Neutron dosimetry by UV and IR spectrophotometry of the newly developed dyed ECE tracks

    International Nuclear Information System (INIS)

    Sohrabi, M.; Sadeghi Bajd, S.

    1990-01-01

    New, large and high-contrasted dyed ECE recoil tracks have been successfully developed. The chief reason for this development has been the provision of large photon-absorbing sites on a non-absorbing unaffected polymer surface for UV and IR spectrophotometry. In this approach, ECE recoil tracks in polycarbonate were dyed using our optimised conditions; sensitisation in 20% by weight acrylic acid at 75 0 C for 3.5 h and dyeing in 3% by weight eosin at 95 0 C for 4 h. Spectrophotometry by UV and IR, track counting and optical densitometry were applied to the samples. These preliminary studies showed some promise for UV absorbance measurements for routine large-scale applications. the results of which are presented and discussed. (author)

  5. Study of the UV-sensitivity of the morphological Salmonella typhimurium mutant

    Energy Technology Data Exchange (ETDEWEB)

    Sakanyan, V A; Dombrovskii, A M; Belokrysenko, S S; Levashev, V S [Vtoroj Moskovskij Gosudarstvennyj Meditsinskij Inst. (USSR)

    1975-05-01

    As regards sensitivity to ultraviolet radiation, the morphological mutant S. typhimurium LT2 WT ED 143 is similar to the ion-mutants E. coli K12. Data are presented on the sensitivity of the mutant and initial strains to ultraviolet radiation at various phases of growth, on the capacity for restoring the bacteriophages P22 and Felix O after irradiation and on the influence of various treatments after ultraviolet irradiation (incubation in minimum media and at 42/sup 0/ C) on the irradiated strains. The results of densitometry of the membrane proteins of the initial and mutant strains point to a connection between unusual morphology, the disruption of division and the enhanced sensitivity to ultraviolet radiation on one hand and the state of the membrane components of the bacterial cell on the other.

  6. Features of integrated ultrasound research of the orbit in the evaluation of the forecast results of prosthetics in subatrophy and microphthalmia

    Directory of Open Access Journals (Sweden)

    E. N. Verigo

    2014-07-01

    Full Text Available A comprehensive echographic study of the orbit using an immersion environment, including high-gray-scale scanning, echo densitometry, volumetric ultrasound scan and color Doppler mapping in 19 patients with post-traumatic subatrophy and 7 patients with congenital microphthalmia. Found that low rates of eye prosthesis in anophthalmia in the late periods is due to insufficient volume of the musculoskeletal stump; if in the orbit exist a reduced in size eye (anteroposterior axis of 10.0 mm or more, the using of prosthesis does not develop deformation of the facial skeleton; the visualization of bloodstream in the great vessels at 2nd — 3rd stages ofsubatrophy and microphthalmia testifies the preservation of blood supply of the structures of the eye and orbit, presence of trophic.

  7. Features of integrated ultrasound research of the orbit in the evaluation of the forecast results of prosthetics in subatrophy and microphthalmia

    Directory of Open Access Journals (Sweden)

    E. N. Verigo

    2012-01-01

    Full Text Available A comprehensive echographic study of the orbit using an immersion environment, including high-gray-scale scanning, echo densitometry, volumetric ultrasound scan and color Doppler mapping in 19 patients with post-traumatic subatrophy and 7 patients with congenital microphthalmia. Found that low rates of eye prosthesis in anophthalmia in the late periods is due to insufficient volume of the musculoskeletal stump; if in the orbit exist a reduced in size eye (anteroposterior axis of 10.0 mm or more, the using of prosthesis does not develop deformation of the facial skeleton; the visualization of bloodstream in the great vessels at 2nd — 3rd stages ofsubatrophy and microphthalmia testifies the preservation of blood supply of the structures of the eye and orbit, presence of trophic.

  8. Use of 5-(4-dimethylaminobenzylidene)rhodanine in quantitating silver grains eluted from autoradiograms of biological material

    International Nuclear Information System (INIS)

    Ludlow, J.W.; Guikema, J.A.; Consigli, R.A.

    1986-01-01

    5-(4-Dimethylaminobenzylidene)rhodanine, a silver-specific dye, was used in a colorimetric assay to quantitate the autoradiographic deposition of silver onto X-ray film after exposure to sodium dodecyl sulfate-polyacrylamide gels of radiolabeled biological material. Silver grains were eluted from autoradiograms with 5 N potassium hydroxide, dissolved in nitric acid, and neutralized with 1 M Trizma Base. The concentration of silver was measured spectrophotometrically owing to the chelation properties of the dye. After corrections for background exposure were made, the silver contents of excised bands were then determined by comparison to a standard curve generated with silver nitrate. We have used this silver assay to quantitate the relative amount of each polypeptide band comprising the polyomavirus structural protein VP2 doublet. The method reported here has proven useful when densitometry is inconvenient (i.e., short distance between bands, irregular shape of bands, very faint bands) in addition to being inexpensive and simple to perform

  9. KARAKTERISASI DAUN MIANA (Plectranthus scutellarioides (L. Bth. DAN BUAH SIRIH (Piper betle L. SECARA FISIKO KIMIA DARI RAMUAN LOKAL ANTIMALARIA DAERAH SULAWESI UTARA

    Directory of Open Access Journals (Sweden)

    Vivi Lisdawati

    2012-10-01

    Full Text Available Multidrug-resistant Plasmodium falciparum strains are an increasing problem in endemic areas and are partly responsible for the worsening malaria situation around the world. New cheap and efftctive compounds active in combination with available drug in the field, such as indegenous traditional medicine, are urgently needed. The aim of this work was to characterize the simplitia and extracts of an indegenous traditional medicine which usually used in North Sulawesi. Since this indigenous traditional medicine has been largely used and well-tolerated in humans, secondary metabolites derivatives of the plants could be in the near future associated with already available drugs in order to delay the spread of P. falciparum resistance. Non polar, semi polar and polar extracts of P. scutellarioides folium and P. bette fruit are prepared of each plants part obtained, then evaluated by using chromatography and densitometry methods following identification.   Keywords: P. falciparum, antimalarial activity, P. scutellarioides folium, P. betle fruit, secondary metabolites

  10. Raman spectroscopy for DNA quantification in cell nucleus.

    Science.gov (United States)

    Okotrub, K A; Surovtsev, N V; Semeshin, V F; Omelyanchuk, L V

    2015-01-01

    Here we demonstrate the feasibility of a novel approach to quantify DNA in cell nuclei. This approach is based on spectroscopy analysis of Raman light scattering, and avoids the problem of nonstoichiometric binding of dyes to DNA, as it directly measures the signal from DNA. Quantitative analysis of nuclear DNA contribution to Raman spectrum could be reliably performed using intensity of a phosphate mode at 1096 cm(-1) . When compared to the known DNA standards from cells of different animals, our results matched those values at error of 10%. We therefore suggest that this approach will be useful to expand the list of DNA standards, to properly adjust the duration of hydrolysis in Feulgen staining, to assay the applicability of fuchsines for DNA quantification, as well as to measure DNA content in cells with complex hydrolysis patterns, when Feulgen densitometry is inappropriate. © 2014 International Society for Advancement of Cytometry.

  11. Osteoporosis: diagnosis and treatment

    International Nuclear Information System (INIS)

    Valino, J.; Mendoza, B.; Bozzola, J.; Vignolo, J.

    1997-01-01

    Osteoporosis represents an important problem in Public Health. It is defined a decrease in bone mass with changes in its microstructure and increased rich of fracture. This bone mass is under the influence of genetic, ethnic, nutrition environment and cultural factors. Usually, osteoporosis is asymptomatic until the occurrence of fracture that are the main morbidity element. Its study implies conventional radiologic methods, bone densitometry, bone remodelation markers and bone biopsy. The importance of prevention must be noted, as well as its treatment on the basis of exercise, calcium and hormonal substitution in the post menopause woman. Other drugs are vitamin D, bifosfonates, calcitonin and fluorine; the factors involved in bone growth on the course of experimentation [es

  12. Multiplex Cathepsin Zymography to Detect Amounts of Active Cathepsins K, L, S, and V.

    Science.gov (United States)

    Platt, Manu O

    2017-01-01

    Cysteine cathepsins are powerful proteases that can degrade other proteins, among which are the extracellular matrix proteins collagen and elastin. Multiplex cathepsin zymography is an assay that can quantify the amount of active cathepsins in a cell or tissue preparation. This method works for measuring the amounts of active cathepsins K, L, S, and V in a cell or tissue preparation without requiring the use of antibodies for specific identification which tremendously reduces cost. This chapter will demonstrate the utility and interpretation of this method with mammalian cells and tissue to quantify amounts of active cathepsins K, L, S, and V without complicating signals of the procathepsin. Multiplex cathepsin zymography has many advantages: (1) it separates cathepsins K, L, S, and V by electrophoretic migration distance, (2) allows visual confirmation of cathepsin identity, (3) does not detect procathepsins, and (4) can be quantified with densitometry.

  13. Status of prompt gamma neutron activation analysis (PGAA) at TRR-1/M1 (Thai Research Reactor-1/Modified 1)

    International Nuclear Information System (INIS)

    Asvavijnijkulchai, Chanchai; Dharmavanij, Wanchai; Siangsanan, Pariwat; Ratanathongchai, Wichian; Chongkum, Somporn

    1999-01-01

    The first prompt gamma activation analysis (PGAA) was designed, constructed and installed at a 6 inch diameter neutron beam port of the Thai Research Reactor-1/Modified 1 (TRR-1/M1) since 1989. Beam characteristic were made by Gd foil irradiation, X-ray film exposing and densitometry scanning consequently. The thermal neutron flux at sample position was measured by Au foil activation, and was about 1 x 10 7 n.cm 2 .sec -1 at 700 kW operating power. The experiments have been conducted successfully. In 1998, the PGAA facility has been developed for the reactor operating power at 1.2 MW. The new PGAA system, e.g., beam shutter, gamma collimator and biological shields have been designed to reduce the leakage of neutrons and gamma radiation to the acceptance levels in accordance with the International Commission on Radiation Protection Publication 60 (ICRP 60). The construction and installation will be completed in April 1999. (author)

  14. Physical exercise can influence local levels of matrix metalloproteinases and their inhibitors in tendon-related connective tissue

    DEFF Research Database (Denmark)

    Koskinen, S O A; Heinemeier, K M; Olesen, J L

    2004-01-01

    Microdialysis studies indicate that mechanical loading of human tendon tissue during exercise or training can affect local synthesis and degradation of type I collagen. Degradation of collagen and other extracellular matrix proteins is controlled by an interplay between matrix metalloproteinases...... (MMPs) and their tissue inhibitors (TIMPs). However, it is unknown whether local levels of MMPs and TIMPs are affected by tendon loading in humans in vivo. In the present experiment, six healthy young men performed 1 h of uphill (3%) treadmill running. Dialysate was collected from microdialysis probes...... (placed in the peritendinous tissue immediately anterior to the Achilles tendon) before, immediately after, 1 day after, and 3 days after an exercise bout. MMP-2 and MMP-9 were measured in dialysate by gelatin zymography, and amounts were quantified by densitometry in relation to total protein...

  15. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  16. Methodology to evaluation of the density in radiographic image

    International Nuclear Information System (INIS)

    Louzada, M.J.Q.; Pela, C.A.; Belangero, W.D.; Santos-Pinto, R.

    1998-01-01

    This study was designed in order to optimize the optical densitometry technique in radiographic images by the setorization of the characteristic curves of the radiographic films. We used 24 radiographs of a stepped aluminium wedge that were taken without rigorous control development and manually revealed. The densitometric values of the steps images and its thickness, for each radiographic, was utilized to generate its particular mathematics expressions that represent its characteristic densitometric curves and then it were used for setorization. The densitometric values were obtained by a Macbeth TD528 densitometer. The study showed an optimization in the representation of the relationship between the optical density of the steps images of the wedge and its correspondent thickness, provided by the setorization, with mean square error around 10 -5 . This optimization will allow the use of this methodology in quantitative evaluations of bone mass, by radiographic images. (author)

  17. Molecular and component volumes of N,N-dimethyl-N-alkylamine N-oxides in DOPC bilayers

    DEFF Research Database (Denmark)

    Belicka, Michal; Klacsova, Maria; Karlovska, Janka

    2014-01-01

    The volumetric properties of fluid bilayers formed of dioleoylphosphatidylcholine (DOPC) with incorporated N ,N -dimethyl-N -alkylamine N -oxides (Cn NO, n = 6, 10–18 is the even number of carbons in alkyl chain) were studied by vibrating tube densitometry in the temperature interval from 20 °C...... to 50 °C. It was found that the DOPC and Cn NO mixed ideally in the investigated composition range and hence the molecular volumes of DOPC (V DOPC) and incorporated Cn NO (V CnNO) were constant and additive within error limits. From the temperature dependencies of the molecular volumes of DOPC and Cn...... NO their coefficients of isobaric thermal expansivities in the investigated temperature interval were obtained. The V CnNO volumes of Cn NO incorporated into DOPC bilayers showed linear dependencies on the Cn NO alkyl chain length at all measured temperatures. This allowed to calculate the component volume of the Cn...

  18. Osteodensitometry and osteoporosis. Current concepts and strategies for the future

    International Nuclear Information System (INIS)

    Restrepo U, Santiago

    1991-01-01

    The osteoporosis is a disease of universal distribution that affects millions of adults in the whole world, producing a high number of fractures, due to insufficiency that generates a significant morbidity and mortality. This condition is especially frequent in post menopause women. Some concepts about the bone structure, and the principal characteristics of the different methods to quantify the bone mass (conventional radiology, radiogrametry, photo densitometry, single photon absorbitometry, dual photon absorbitometry are reviewed. Finally, the advantages, disadvantages, levels of sensibility, precision, of the different techniques are established. An emphasis is made on the special capacity of the quantitative computed axial tomography to detect as a selective way the alterations of the spongiest bone

  19. [Clinical observation on corneal transparency after small incision lenticule extraction surgery].

    Science.gov (United States)

    Zhang, L; Wang, Y; Cui, T; Zhao, W; Cheng, W B

    2018-01-11

    Objective: To evaluate the changes of corneal transparency over the 1-year period after small incision lenticule extraction (SMILE) according to corneal Scheimpflug densitometry. Methods: Prospective cohort study. Fifty-five patients (100 eyes) with myopia (19 male and 36 female, aged 18 to 39 years with average of 24) who underwent SMILE and regular follow-up for at least 1 year at Tianjin Eye Hospital were enrolled. Examinations took place before SMILE and postoperatively at 1 day, 1 week, and 1, 3, 6, and 12 months. The preoperative spherical equivalent of surgical refractive correction was (-5.75±1.64) D. Corneal densitometry (CD) data were calculated automatically by the Pentacam Scheimpflug system and expressed in gray scale units (GSU), from 0 (completely transparent) to 100 (completely opaque). During the analysis of corneal densitometry, the average corneal optical density of three concentric radial zones centered on the apex of the cornea ≤2 mm, >2 mm and ≤6 mm, >6 mm and ≤10 mm diameter) were applied, and three layers were defined according to different corneal depths (the anterior 120 μm as 1st layer, and the posterior 60 μm as 3rd layer, and the center part between them of the cornea as 2nd layer). The automatic release mode was applied in order to avoid operator-induced errors. The preoperative and postoperative values in different corneal layers and different concentric radial zones were compared using Kruskal-Wallis. Results: Ninty-three eyes(93%) of all eyes achieved uncorrected distance visual acuity (UCVA) of 0.8 or better on the first day postoperatively, and 96% (96 of 100 eyes) achieved UCVA of 0.8 or better in the first week postoperatevely, and all eyes 100% (100 of 100 eyes) achieved UCVA 0.8 or better until the end of our follow-up (in 1 year postoperatively). In general, the difference preoperative and postoperative corneal average optical density is of no statistical significance (χ(2)=8.446, P =0.207), specifically, the

  20. Postpartum osteoporosis associated with proximal tibial stress fracture

    Energy Technology Data Exchange (ETDEWEB)

    Clemetson, I.A.; Anderson, S.E. [Department of Radiology, University Hospital of Bern, Inselspital, 3010, Bern (Switzerland); Popp, A.; Lippuner, K. [Department of Osteology, University Hospital of Bern, Inselspital, 3010, Bern (Switzerland); Ballmer, F. [Knee and Sports Medicine Unit, Lindenhofspital Bern, 3012, Bern (Switzerland)

    2004-02-01

    A 33-year-old woman presented with acute nonspecific knee pain, 6 months postpartum. MR imaging, computed tomography and radiography were performed and a proximal tibia plateau insufficiency fracture was detected. Bone densitometry demonstrated mild postpartum osteoporosis. To our knowledge these findings have not been described in this location and in this clinical setting. The etiology of the atraumatic fracture of the tibia is presumed to be due to a low bone mineral density. The bone loss was probably due to pregnancy, lactation and postpartum hormonal changes. There were no other inciting causes and the patient was normocalcemic. We discuss the presence of a postpartum stress fracture in a hitherto undescribed site in a patient who had lactated following an uncomplicated pregnancy and had no other identifiable cause for a stress fracture. (orig.)

  1. NaI(Tl) detectors modeling in MCNP-X and Gate/Geant4 codes

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Salgado, Cesar Marques, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    NaI (Tl) detectors are widely used in gamma-ray densitometry, but their modeling in Monte Carlo codes, such as MCNP-X and Gate/Geant4, needs a lot of work and does not yield comparable results with experimental arrangements, possibly due to non-simulated physical phenomena, such as light transport within the scintillator. Therefore, it is necessary a methodology that positively impacts the results of the simulations while maintaining the real dimensions of the detectors and other objects to allow validating a modeling that matches up with the experimental arrangement. Thus, the objective of this paper is to present the studies conducted with the MCNPX and Gate/Geant4 codes, in which the comparisons of their results were satisfactory, showing that both can be used for the same purposes. (author)

  2. Computed-tomographic determination of mineral content of bones

    International Nuclear Information System (INIS)

    Delov, I.; Tabakov, S.

    1988-01-01

    The problem of precise computed-tomographic densitometry of the mineral content of bones is pointed out. A method is proposed including the use of standard density and observance of definite radiation, scanning and image estimation parameters. A good correlation of the results obtained for the mineral content of the lumbar vertebrae with literature data are reported. A method is also described for determining the mineral content of tubular bones based on densiprofile check-up of the computed-tomographic density. The procedure takes 10-15 minutes and includes 1 or 2 scans. It might therefore gain wide acceptance for the diagnosis and tracing of osteoporosis and other osteopathies associated with distrorted calcium metabolism

  3. Osteoporosis: primary prevention in the community.

    Science.gov (United States)

    Loh, K Y; Shong, H K

    2007-10-01

    The incidence of osteoporosis is increasing worldwide. It has great impact on the life of the elderly population. The most significant medical consequence of osteoporosis is fragility fracture which without proper treatment will cause severe medical and psychosocial complications. The overall cost in managing osteoporosis and its related fractures is escalating. Using bone densitometry to measure bone mineral density is useful in the diagnosis of osteoporosis but it is costly and not feasible in the community. Drugs such as estrogen replacement, raloxifene and calcitonin are effective in prevention and treatment of osteoporosis but they are also expensive. Identifying modifiable risk factors such as smoking, lack of exercise, low dietary calcium and vitamin D intake and healthy life style remain strategy in the primary prevention of osteoporosis in the community.

  4. Assessment of bone density in patients with scoliosis neuromuscular secondary to cerebral palsy

    Directory of Open Access Journals (Sweden)

    Charbel Jacob Júnior

    2014-09-01

    Full Text Available OBJECTIVE: To evaluate bone mineral density in patients with neuromuscular scoliosis secondary to spastic quadriplegic cerebral palsy. METHODS: A prospective descriptive study in which, in addition to bone densitometry, the anthropometric data of the patients were assessed. As inclusion criterion we adopted patients with spastic quadriplegic cerebral palsy, wheelchair users, aged between 10 and 20 years and with neuromuscular scoliosis. RESULTS: We evaluated 31 patients, 20 female, whose average age was 14.2 years. The mean bone density was -3.2 standard deviation (Z-score, with mean biceps circumference of 19.4 cm, calf circumference 18.6 cm and BMI of 13.6 kg/m². CONCLUSION: There is a high incidence of osteoporosis in patients with neuromuscular scoliosis secondary to spastic quadriplegic cerebral palsy.

  5. Seven year follow-up after advanced surface ablation with excimer laser for treatment of myopia: Long-term outcomes of cooling PRK and LASEK

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    Purpose: To evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA and CDVA), corneal haze, corneal densitometry and patient satisfaction up to 7 years after Photorefractive Keratectomy with cooling (cPRK) and Laser-Assisted Sub-epithelial Keratectomy...... (LASEK) for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Methods: Retrospective follow-up study of eyes treated with cPRK or LASEK for all degrees of myopia from 2007 to 2009 at the Department of Ophthalmology...... laser with eye-tracker (Carl Zeiss Meditec AG, Jena, Germany) was used for photoablation in both procedures. Optical zone size ranged from 5.50 to 6.00 mm in both procedures, and maximum attempted spherical correction was -8.50 D. cPRK was performed as a standard PRK procedure, but with immediately...

  6. Total skeletal uptake of diphosphonate in Paget's bone disease and rheumatoid arthritis

    International Nuclear Information System (INIS)

    Cabrejas, M.J.; Mautclen, C.A.; Fromm, G.

    1982-01-01

    Sup(99m) Technetium-diphosphonates (99m-Tc-DP) are very satifactory agents to quantify total skeletal uptake (TSU) in normal and pathological conditions. Although the intimate mechanism of skeletal localization of 99m-Tc-DP is not completely understood the test appears to be a very sensitive index of increased bone turnover. TSU can be determined by several methods: urine collection, whole body counter retention and gamma camara body retention studies. The urine collection method seems to be an easy and reliable method, having the advantage that no expensive device is needed. Further studies on the skeletal uptake of 99m-Tc-DP, in normal subjects and pathological conditions, with special emphasis on patients with rheumatoid arthritis, are reported. Correlation of these data with other tests indicating bone turnover, such as cortical bone loss determined by densitometry or urinary hydroxyproline excretion, supports previous reports that the TSU is a useful parameter to evaluate bone metabolism

  7. Document Examination: Applications of Image Processing Systems.

    Science.gov (United States)

    Kopainsky, B

    1989-12-01

    Dealing with images is a familiar business for an expert in questioned documents: microscopic, photographic, infrared, and other optical techniques generate images containing the information he or she is looking for. A recent method for extracting most of this information is digital image processing, ranging from the simple contrast and contour enhancement to the advanced restoration of blurred texts. When combined with a sophisticated physical imaging system, an image pricessing system has proven to be a powerful and fast tool for routine non-destructive scanning of suspect documents. This article reviews frequent applications, comprising techniques to increase legibility, two-dimensional spectroscopy (ink discrimination, alterations, erased entries, etc.), comparison techniques (stamps, typescript letters, photo substitution), and densitometry. Computerized comparison of handwriting is not included. Copyright © 1989 Central Police University.

  8. Partial molar volumes of proteins: amino acid side-chain contributions derived from the partial molar volumes of some tripeptides over the temperature range 10-90 degrees C.

    Science.gov (United States)

    Häckel, M; Hinz, H J; Hedwig, G R

    1999-11-15

    The partial molar volumes of tripeptides of sequence glycyl-X-glycine, where X is one of the amino acids alanine, leucine, threonine, glutamine, phenylalanine, histidine, cysteine, proline, glutamic acid, and arginine, have been determined in aqueous solution over the temperature range 10-90 degrees C using differential scanning densitometry . These data, together with those reported previously, have been used to derive the partial molar volumes of the side-chains of all 20 amino acids. The side-chain volumes are critically compared with literature values derived using partial molar volumes for alternative model compounds. The new amino acid side-chain volumes, along with that for the backbone glycyl group, were used to calculate the partial specific volumes of several proteins in aqueous solution. The results obtained are compared with those observed experimentally. The new side-chain volumes have also been used to re-determine residue volume changes upon protein folding.

  9. Definition of a facility for experimental studies of two-phase flows and heat transfer in porous materials

    International Nuclear Information System (INIS)

    Reda, D.C.; Eaton, R.R.

    1981-01-01

    A facility-development effort is currently underway at Sandia National Laboratories in order to create an experimental capability for the study of two-phase, steam/water flows through a variety of porous media. The facility definition phase of this project is described. Equations are derived for the steady, adiabatic, macroscopically-linear two-phase flow of a single-component fluid through a porous medium, including energy transfer both by convection and conduction. These equations are then solved to give relative permeabilities for the steam and water phases as functions of known and/or measurable quantities. A viable experimental approach was thereby formulated, leading to the definition of facility components and instrumentation requirements, including the application of gamma-beam densitometry for the measurement of liquid-saturation distributions in porous media. Finally, a state-of-the-art computer code was utilized to numerically simulate the proposed experiments, providing an estimate of the facility operating envelope

  10. Current state of diagnostic and treatment of osteoporosis in real-life clinical practice (a pilot study

    Directory of Open Access Journals (Sweden)

    O.A. Nikitinskaya

    2014-01-01

    Full Text Available We report the results of a pilot study on physician awareness of modern diagnostic methods and drug therapy of osteoporosis (OP and the use of this knowledge in daily practice. A pilot survey among physicians demonstrated that experts (rheumatologists, endocrinologists, etc. have a high level of awareness of the OP problem and successfully use this knowledge in daily practice (modern diagnosis, prevention, and treatment methods. They widely prescribe original drugs and certain generics that were shown to be effective in post-marketing surveillance. Limitations of the study: 1 only physicians dealing with diagnosis and treatment of OP were surveyed; hence, the conclusions of this study are valid only for this group of physicians; 2 only physicians working in large cities who can use modern diagnosis methods (densitometry; determination of bone turnover markers participated in the study; 3 Prolia medication, which has been used in Russia since 2013, was not taken into account in the questionnaire. 

  11. Characterisation of cerebral blood flow via determining the vascular mean transit time

    International Nuclear Information System (INIS)

    Lindner, P.; Thelen, M.

    1987-01-01

    By using a recently developed algorithm it is possible to quantify the dynamic information of a DSA sequence of the brain. The theory of algorithm allows to calculate vascular mean transit from time density curves. The algorithm minimizes the problems of densitometry with regard to 'quantitative DSA'. There is a strong correlation between vascular mean transit times and cerebral blood flow values, and therefore the results for mean transit times also correspond to the results obtained for cerebral blood flow. By computerized postprocessing of DSA-images it is possible to generate functional images of the brain with a spatial resolution that had not been attainable so far. The images represent the distribution pattern of reverse vascular mean transit times. The results from 36 patients with proven stenoses of the cervical vessels are reported. (orig.) [de

  12. Effect of clofibric acid on desmin and vimentin contents in rat myocardiocytes.

    Science.gov (United States)

    Sampayo-Reyes, Adriana; Narro-Juárez, Antonio; Saíd-Fernández, Salvador; Lozano-Garza, Héctor G; Vargas-Villarreal, Javier; Mata-Cárdenas, Benito D; Morales-Aguilera, Antonio; González-Garza, María Teresa; Cortés-Gutiérrez, Elva I; Cerda-Flores, Ricardo M; Martínez-Rodríguez, Herminia G

    2006-01-01

    The aim of this experimental study was to analyze in vitro effects of clofibric acid on vimentin and desmin contents in rat myocardiocytes, which was carried out in primary myocardiocyte cells that were treated only with clofibric acid at 0.1 mM. The measurement of vimentin and desmin were done by Western blotting and densitometry. This study showed that myocardiocytes exposed to clofibric acid exhibit a 26.3% decrease in vimentin and a 42.1% decrease in desmin. Considering the role that these intermediate filaments play in the anchorage and cellular organization of myocardiocytes, the decrease of desmin and vimentin observed in cells treated with clofibric acid may be partially responsible for the adverse effects observed in patients. In conclusion, the alteration of cytoskeletal proteins may be a cause of cardiopathy in patients treated with these compounds.

  13. Testosterone is an independent determinant of bone mineral density in men with type 2 diabetes mellitus.

    Science.gov (United States)

    Vasilkova, Olga; Mokhort, Tatiana; Sanec, Igor; Sharshakova, Tamara; Hayashida, Naomi; Takamura, Noboru

    2011-01-01

    Although many reports have elucidated pathophysiological characteristics of abnormal bone metabolism in patients with type 2 diabetes mellitus (DT2), determinants of bone mineral density (BMD) in patients with DT2 are still controversial. We examined 168 Belarussian men 45-60 years of age. Plasma total cholesterol (TC), high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, very low-density lipoprotein cholesterol, triglycerides, hemoglobin A(1c) (HbA(1c)), immunoreactive insulin, and C-reactive protein concentrations were assessed. BMD was measured using dual energy X-ray densitometry of the lumbar spine (L(1)-L(4)). Total testosterone (TT) and sex hormone-binding globulin were measured, and free testosterone (FT) was calculated. Using univariate linear regression analysis, BMD of the lumbar spine was significantly correlated with FT (r=0.32, pDT2.

  14. Preparation and characterisation of high-density ionic liquids incorporating halobismuthate anions.

    Science.gov (United States)

    Cousens, Nico E A; Taylor Kearney, Leah J; Clough, Matthew T; Lovelock, Kevin R J; Palgrave, Robert G; Perkin, Susan

    2014-07-28

    A range of ionic liquids containing dialkylimidazolium cations and halobismuthate anions ([BiBr(x)Cl(y)I(z)](-) and [Bi2Br(x)Cl(y)I(z)](-)) were synthesised by combining dialkylimidazolium halide ionic liquids with bismuth(III) halide salts. The majority were room temperature liquids, all with very high densities. The neat ionic liquids and their mixtures with 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide were characterised using Densitometry, Viscometry, NMR Spectroscopy, Electrospray Ionisation Mass Spectrometry (ESI), Liquid Secondary Ion Mass Spectrometry (LSIMS), Matrix-assisted Laser Desorption/Ionization Mass Spectrometry (MALDI), X-Ray Photoelectron Spectroscopy (XPS) and Thermogravimetric Analysis (TGA), to establish their speciation and suitability for high-temperature applications.

  15. Interfacial shear modeling in two-phase annular flow

    International Nuclear Information System (INIS)

    Kumar, R.; Edwards, D.P.

    1996-11-01

    A new interfacial shear stress model called the law of the interface model, based on the law of the wall approach in turbulent flows, has been developed and locally applied in a fully developed, adiabatic, two-phase annular flow in a duct. Numerical results have been obtained using this model in conjunction with other models available in the literature that are required for the closure of the continuity and momentum equations. These results have been compared with droplet velocity data (using laser Doppler velocimetry and hot film anemometry), void fraction data (using gamma densitometry) and pressure drop data obtained in a R-134A refrigerant test facility. Droplet velocity results match the experimental data well, however, the prediction of the void fraction is less accurate. The poor prediction of void fraction, especially for the low void fraction cases, appears to be due to the lack of a good mechanistic model for entrainment

  16. Interfacial shear modeling in two-phase annular flow

    International Nuclear Information System (INIS)

    Kumar, R.; Edwards, D.P.

    1996-07-01

    A new interfacial shear stress model called the law of the interface model, based on the law of the wall approach in turbulent flows, has been developed and locally applied in a fully developed, adiabatic, two-phase annular flow in a duct. Numerical results have been obtained using this model in conjunction with other models available in the literature that are required for the closure of the continuity and momentum equations. These results have been compared with droplet velocity data (using laser Doppler velocimetry and hot film anemometry), void fraction data (using gamma densitometry) and pressure drop data obtained in a R-134A refrigerant test facility. Droplet velocity results match the experimental data well, however, the prediction of the void fraction is less accurate. The poor prediction of void fraction, especially for the low void fraction cases, appears to be due to the lack of a good mechanistic model for entrainment

  17. Induction of CD3 delta epsilon omega by phorbol 12-myristate 13-acetate

    DEFF Research Database (Denmark)

    Vangsted, A; Neisig, A; Wallin, H

    1993-01-01

    The effect of phorbol 12-myristate 13-acetate (PMA) on the synthesis, assembly and processing of the components of the T cell receptor (TcR) was studied with special focus on the CD3 omega chain. Treatment of the human leukemic T cell line Jurkat with PMA increased the synthesis of the Ti alpha, CD......3 gamma and CG3 zeta chains two- to threefold and the synthesis of Ti beta and CD3 delta epsilon omega complexes five- to sevenfold as assessed by metabolic labeling, immunoprecipitation and sodium dodecyl sulfate-polyacrylamide gel electrophoresis followed by scanning densitometry. The amount...... of TcR complexes expressed on the cell surface was decreased after 16 h of PMA treatment. Based on these results we propose a role of CD3 omega in retention of TcR complexes. From PMA-treated CEM cells more than 50-fold the amount of CD3 delta epsilon omega complexes was immunoprecipitated as compared...

  18. Analysis of correlation between initial alveolar bone density and apical root resorption after 12 months of orthodontic treatment without extraction

    Directory of Open Access Journals (Sweden)

    Paula Cabrini Scheibel

    2014-10-01

    Full Text Available OBJECTIVE: The aim of the present study was to investigate the correlation between initial alveolar bone density of upper central incisors (ABD-UI and external apical root resorption (EARR after 12 months of orthodontic movement in cases without extraction. METHODS: A total of 47 orthodontic patients 11 years old or older were submitted to periapical radiography of upper incisors prior to treatment (T1 and after 12 months of treatment (T2. ABD-UI and EARR were measured by means of densitometry. RESULTS: No statistically significant correlation was found between initial ABD-UI and EARR at T2 (r = 0.149; p = 0.157. CONCLUSION: Based on the present findings, alveolar density assessed through periapical radiography is not predictive of root resorption after 12 months of orthodontic treatment in cases without extraction.

  19. Analysis of correlation between initial alveolar bone density and apical root resorption after 12 months of orthodontic treatment without extraction

    Science.gov (United States)

    Scheibel, Paula Cabrini; Ramos, Adilson Luiz; Iwaki, Lilian Cristina Vessoni; Micheletti, Kelly Regina

    2014-01-01

    OBJECTIVE: The aim of the present study was to investigate the correlation between initial alveolar bone density of upper central incisors (ABD-UI) and external apical root resorption (EARR) after 12 months of orthodontic movement in cases without extraction. METHODS: A total of 47 orthodontic patients 11 years old or older were submitted to periapical radiography of upper incisors prior to treatment (T1) and after 12 months of treatment (T2). ABD-UI and EARR were measured by means of densitometry. RESULTS: No statistically significant correlation was found between initial ABD-UI and EARR at T2 (r = 0.149; p = 0.157). CONCLUSION: Based on the present findings, alveolar density assessed through periapical radiography is not predictive of root resorption after 12 months of orthodontic treatment in cases without extraction. PMID:25715722

  20. Heavy-Ion Imaging Applied To Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Fabrikant, J. I.; Tobias, C. A.; Capp, M. P.; Benton, E. V.; Holley, W. R.; Gray, Joel E.; Hendee, William R.; Haus, Andrew G.; Properzio, William S.

    1980-08-18

    Heavy particle radiography is a newly developed noninvasive low dose imaging procedure with increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high energy ions, primarily carbon and neon, at the BEVALAC accelerator at the Lawrence Berkeley Laboratory. The research program applied to medicine utilizes heavy-ion radiography for low dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures and brain and spinal neoplasms. The presentation will be illustrated with clinical cases under study. Discussion will include the potential of heavy-ion imaging, and particularly reconstruction tomography, as an adjunct to existing diagnostic imaging procedures in medicine, both for the applications to the diagnosis, management and treatment of clinical cancer in man, but also for the early detection of small soft tissue tumors at low radiation dose.

  1. Quantitative film detection of 3H and 14C in polyacrylamide gels by fluorography

    International Nuclear Information System (INIS)

    Laskey, R.A.; Mills, A.D.

    1975-01-01

    Methods which use the scintillator PPO to record film images of 3 H in chromatograms and polyacrylamide gels (fluorography) have been described elsewhere. This paper demonstrates that pre-exposure of the film to a brief flash of light greatly increases the sensitivity of fluorography. Pre-exposure also permits quantitative interpretation of the film image, because it corrects the non-linear relationship between redioactivity of the sample and absorbance of the film image. Therefore the distribution of radioactivity in the sample is accurately represented by micro-densitometry of the image obtained on pre-exposed film. Using pre-exposed film 300 dis. 3 H/min or 30 dis. 14 C/min can be detected in a band in a gel in a 24-h exposure. The appendix describes revisions and extensions of existing fluorographic procedures, including application to agarose gels and a rapid procedure for recovering PPO for re-use. (orig.) [de

  2. HPTLC-FLD-SERS as a facile and reliable screening tool: Exemplarily shown with tyramine in cheese.

    Science.gov (United States)

    Wang, Liao; Xu, Xue-Ming; Chen, Yi-Sheng; Ren, Jie; Liu, Yun-Tao

    2018-04-01

    The serious cytotoxicity of tyramine attracted marked attention as it induced necrosis of human intestinal cells. This paper presented a novel and facile high performance thin-layer chromatography (HPTLC) method tailored for screening tyramine in cheese. Separation was performed on glass backed silica gel plates, using methanol/ethyl acetate/ammonia (6/4/1 v/v/v) as the mobile phase. Special efforts were focused on optimizing conditions (substrate preparation, laser wavelength, salt types and concentrations) of surface enhanced Raman spectroscopy (SERS) measurements directly on plates after derivatization, which enabled molecule-specific identification of targeted bands. In parallel, fluorescent densitometry (FLD) scanning at 380SERS provided a new horizon in fast and reliable screening of sophisticated samples like food and herb drugs, striking an excellent balance between specificity, sensitivity and simplicity. Copyright © 2017. Published by Elsevier B.V.

  3. X-ray and visible light transmission as two-dimensional, full-field moisture-sensing techniques: A preliminary comparison

    International Nuclear Information System (INIS)

    Tidwell, V.C.; Glass, R.J.

    1992-01-01

    Two independent high-resolution moisture-sensing techniques, x-ray absorption and light transmission, have been developed for use in two-dimensional, thin-slab experimental systems. The techniques yield full-field measurement capabilities with exceptional resolution of moisture content in time and space. These techniques represent powerful tools for the experimentalist to investigate processes governing unsaturated flow and transport through fractured and nonfractured porous media. Evaluation of these techniques has been accomplished by direct comparison of data obtained by means of the x-ray and light techniques as well as comparison with data collected by gravimetric and gamma-ray densitometry techniques. Results show excellent agreement between data collected by the four moisture-content measurement techniques. This program was established to support the Yucca Mountain Site Characterization Project

  4. Characterization and visualization of cholecystokinin receptors in rat brain using [3H]pentagastrin

    International Nuclear Information System (INIS)

    Gaudreau, P.; Quirion, R.; St Pierre, S.; Pert, C.B.

    1983-01-01

    [ 3 H]Pentagastrin binds specifically to an apparent single class of CCK receptors on slide-mounted sections of rat brain (KD . 5.6 nM; Bmax . 36.6 fmol/mg protein). This specific binding is temperature-dependent and regulated by ions and nucleotides. The relative potencies of C-terminal fragments of CCK-8(SO 3 H), benzotript and proglumide in inhibiting specific [ 3 H]pentagastrin binding to CCK brain receptors reinforce the concept of different brain and pancreas CCK receptors. CCK receptors were visualized by using tritium-sensitive LKB film analyzed by computerized densitometry. CCK receptors are highly concentrated in the cortex, dentate gyrus, granular and external plexiform layers of the olfactory bulb, anterior olfactory nuclei, olfactory tubercle, claustrum, accumbens nucleus, some nuclei of the amygdala, thalamus and hypothalamus

  5. OSTEOPOROSIS IN SYSTEMIC LUPUS ERYTHEMATOSUS

    Directory of Open Access Journals (Sweden)

    N V Seredavkina

    2009-01-01

    Full Text Available Patients with systemic lupus erythematosus (SLE form a high risk group osteoporosis (OP. Its main causes are autoimmune inflammation, concomitant pathology, and their treatment. When OP occurs in SLE, bone mass loss is shown to occur early and is associated with the use of glucocorticosteroids (GC. To prevent OP, all patients with SLE should modify their lifestyle. To verify bone changes, densitometry is performed in patients who have risk factors of OP and/or a menopause. Calcium preparations and vitamin D are used to prevent OP; bisphosphonates that significantly reduce the risk of fractures of the vertebral column and femoral neck are employed for therapy of OP. A SLE patient with gluco-corticoid-induced OP and a good effect of bisphophonate treatment is described.

  6. Cold flow study of liquid cooled pebble bed reactor (LC-PBR) through radioisotope techniques

    International Nuclear Information System (INIS)

    Verma, Rupesh; Upadhyay, Rajesh K.; Pant, H.J.

    2017-01-01

    As the world's demand for energy continues to increase burning of coal, oil and natural gases continue to increase which will eventually cause build-up in emission of greenhouse gasses. To overcome this challenge worldwide effort is in progress to develop an economical, more efficient and safer nuclear power. Higher thermal efficiency and enhances safety feature of Generation IV liquid cooled pebble bed reactor (LC-PBR) makes it viable option to replace existing nuclear reactor. However, this reactor is still in research stage and need detailed study before commercialization. In current work, hydrodynamics of LC-PBR is studied by using radioisotope based techniques, radioactive particle tracking and gamma-ray densitometry. Pebble flow profile and distribution are measured for different operating conditions. Optimal operating parameters are identified for operating LC-PBR based on hydrodynamics. (author)

  7. Studies on osteoporosis in Chile using isotope-related techniques

    International Nuclear Information System (INIS)

    Lobo, G.; Palma, T.; Cortes-Toro, E.

    1996-01-01

    Several studies on bone densitometry measurements in healthy individuals have been performed in Chile. However due to the fact that different techniques and no uniform protocols have been used to select patients, the results obtained are not suitable as reference values for a normal chilean population. Therefore, foreign reference values are used. This study will select healthy normal individuals, typical urban chilean residents, and measure bone density using the DEXA technique. The selection will be made according to a well defined protocol. Serum osteocalcin, a marker of bone remodeling, will be measured in all subjects as a means-a assessing bone metabolism. Bone trace element composition will be measured in selected subjects. Samples will be obtained by biopsy or through normal surgical procedures and will be analyzed by neutron activation analysis. (author)

  8. Severe bone demineralisation is associated with higher mortality in children with cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Reilly, R

    2009-02-01

    Decreased bone mineral density (BMD) is an emerging problem for clinicians who care for children with Cystic fibrosis (CF). The aim of this study was to determine prevalence and assess risk factors for reduced BMD in our adolescent population with CF. All bone densitometry scans (n=99) performed on children (n=79) with a mean age 13.6 (10-19.2) years over a 7 year period (2000-2007) were reviewed. Patient records were reviewed for correlating clinical data. Low BMD is frequently present in adults and children with variable reports (36-66%). In our study, BMD expressed as z score of L2-L4 spine was reduced in a total of 50% children with a preponderance of males. Bone demineralization was strongly associated with increasing age (p=0.03), diminished lung function (p=0.027), reduced body mass index (p=0.001) and treatment with oral corticosteroids (p=0.02).

  9. Current Approaches to Diagnosis and Classification Features of Neuroosteoarthropathy Charcot (literature review

    Directory of Open Access Journals (Sweden)

    Balatiuk Irina

    2016-12-01

    Full Text Available The article provides the analysis of the publications of domestic and foreign authors on such complication of diabetes as diabetic Charcot osteoarthropathy. It formulates modern domestic classification of diabetic foot syndrome. It has been stated that diabetic foot syndrome is a serious medical and social problem, due to the high level of disability of patients, it causes significant social and economic losses to society. Pathogenetic basis for the development of diabetic osteoarthropathy is a combination of uncontrolled bone resorption and the lack of sensitivity of the defense, which leads to the destruction of joints. The gold standard for diagnosis of Charcot osteoarthropathy is X-ray densitometry that allows you to objectively assess the state of bone mineral density.

  10. Experimental studies for the development of a new method for stroke volume measuring using X-ray videodensitometry

    International Nuclear Information System (INIS)

    Odenthal, H.J.

    1982-01-01

    Quantitative videodensitometry was studied with a view to its possible application as a new, non-invasive method of measuring cardiac stroke volume. To begin with, the accuracy of roentgen volumetric measurements was determined. After this, blood volume variations were measured by densitometry in five animal experiments. The findings were compared with the volumes measured by a flowmeter in the pulmonary artery. The total stroke volume was found to be proportional to the difference between the maximum and mean densitometric volume. A comparison between videodensitometry and other non-invasive methods showed that, in a stable circulatory system, the results of videodensitometry are equally reliable as, or even more reliable than, those of the conventional methods. (orig./MG) [de

  11. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Lindsey, J.S.

    1990-01-01

    One of our long-term goals is to develop robotic workstations for automated synthetic chemistry. Toward that goal we have constructed a 2nd generation instrument for performing TLC analysis. TLC has important advantages (over HPLC and GC) in analysis of crude reaction samples and parallel sample development. The TLC instrument consist of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) plate densitometry. A robot is used to move plates among stations. The combination of fixed automation and robotics gives high sample throughout (up to 10 samples per hour). A second robot performs reaction chemistry and feeds samples to the TLC instrument, thus enabling TLC analysis at the same time as synthetic reactions proceed on the workstation

  12. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Haynes, E.; Kline, S.; Lindsey, J.S.

    1991-01-01

    We have constructed a second generation instrument for performing automated thin layer chromatography (TLC), The TLC instrument Consists of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) densitometry. A robot is used to move TLC plates among stations. The TLC instrument functions either as a stand-alone unit or as one analytical module in a robotic workstation for synthetic chemistry. An integrated hardware and software architecture enables automatic TLC analysis of samples produced concurrently from synthetic reactions in progress on the workstation. The combination of fixed automation and robotics gives a throughput of 12 TLC samples per hour. From these results a blueprint has emerged for an advanced automated TLC instrument with far greater throughput and analytical capabilities

  13. The procedure of ethanol determination in wine by enzyme amperometric biosensor

    Directory of Open Access Journals (Sweden)

    Dzyadevych S. V.

    2009-08-01

    Full Text Available Aim. Development of the procedure of ethanol determination in wine by an enzyme amperometric biosensor. Methods. The amperometric biosensor method of ethanol analysis has been used in this work. Results. The paper presents comparative analysis of two methods of alcohol oxidase (AO immobilization for development of amperometric biosensor for ethanol determination in wine. The method of AO immobilization in glutaraldehyde vapour was chosen as optimal for this purpose. The selectivity, operational and storage stability, and pH-optimum for operation of the created biosensor were determined. The procedure of ethanol determination in wine by amperometric biosensor on the basis of platinum printed electrode SensLab and AO was optimized. The analysis of ethanol concentration in wine and must samples was carried out using the developed high-stable biosensor. A good correlation between the data obtained by the biosensor and densitometry methods was shown. Conclusion. The proposed method of ethanol analysis could be used in wine production

  14. Postpartum osteoporosis associated with proximal tibial stress fracture

    International Nuclear Information System (INIS)

    Clemetson, I.A.; Anderson, S.E.; Popp, A.; Lippuner, K.; Ballmer, F.

    2004-01-01

    A 33-year-old woman presented with acute nonspecific knee pain, 6 months postpartum. MR imaging, computed tomography and radiography were performed and a proximal tibia plateau insufficiency fracture was detected. Bone densitometry demonstrated mild postpartum osteoporosis. To our knowledge these findings have not been described in this location and in this clinical setting. The etiology of the atraumatic fracture of the tibia is presumed to be due to a low bone mineral density. The bone loss was probably due to pregnancy, lactation and postpartum hormonal changes. There were no other inciting causes and the patient was normocalcemic. We discuss the presence of a postpartum stress fracture in a hitherto undescribed site in a patient who had lactated following an uncomplicated pregnancy and had no other identifiable cause for a stress fracture. (orig.)

  15. Requirements for near-real-time accounting of strategic nuclear materials in nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Hakkila, E.A.; Cobb, D.D.; Dietz, R.J.; Shipley, J.P.; Smith, D.B.

    1978-01-01

    A Purex-based nuclear fuel reprocessing plant has been studied for possible incorporation of near-real-time accounting to supplement conventional accounting procedures. Near-real-time accounting of special nuclear materials relies on in-line or at-line flow measurements and plutonium assay of product and waste streams, complemented by conventional analytical chemistry for daily instrument calibrations. In-line alpha monitors could be used for waste stream measurements of plutonium, even in the presence of high beta-gamma fluxes from fission products. X-ray absorption edge densitometry using either K- or L-absorption edges could be used for plutonium concentration measurements in main product streams. Some problem areas identified in waste stream measurements include measurements of leached hulls and of centrifuge sludge. Conventional analytical chemical methods for measuring plutonium in weapons grade material can be modified for reprocessed plutonium. Analytical techniques requiring special precautions will be reviewed

  16. Partial hypopituitarism and Langerhans cell histiocytosis

    Science.gov (United States)

    Balaguruswamy, S; Chattington, P D

    2011-01-01

    A case of multisystem Langerhans cell histiocytosis with pituitary involvement nearly 20 years after initial presentation. A 48-year-old man had histiocytosis X 22 years ago initially involving the groin; subsequently his external auditory meatus, scalp, gum, mandibular bone, perineum and axilla were involved and treated. The pituitary gland was involved 4 years ago. A thyrotropin-releasing hormone test showed delayed response suggestive of hypothalamic disease. Prolactin levels were normal. A gonadotropin-releasing hormone test showed impaired testosterone and gonadotrophin response in keeping with pituitary disease. A glucagon stimulation test showed an impaired growth hormone response but a normal cortisol increase. MRI pituitary showed an empty sella. There was no evidence of diabetes insipidus. Bone mineral densitometry was normal. He has partial hypopituitarism needing thyroxine and testosterone replacement. He also developed type 2 diabetes mellitus 9 years ago. He is closely monitored for any development of diabetes insipidus and the need for growth hormone supplementation. PMID:22715201

  17. Secondary and tertiary hyperparathyroidism.

    Science.gov (United States)

    Jamal, Sophie A; Miller, Paul D

    2013-01-01

    We reviewed the etiology and management of secondary and tertiary hyperparathyroidism. Secondary hyperparathyroidism is characterized by an increase in parathyroid hormone (PTH) that is appropriate and in response to a stimulus, most commonly low serum calcium. In secondary hyperparathyroidism, the serum calcium is normal and the PTH level is elevated. Tertiary hyperparathyroidism is characterized by excessive secretion of PTH after longstanding secondary hyperparathyroidism, in which hypercalcemia has ensued. Tertiary hyperparathyroidism typically occurs in men and women with chronic kidney disease usually after kidney transplant. The etiology and treatment of secondary hyperparathyroidism is relatively straightforward whereas data on the management of tertiary hyperparathyroidism is limited to a few small trials with short follow-up. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  18. PROCEDURES FOR ACCURATE PRODUCTION OF COLOR IMAGES FROM SATELLITE OR AIRCRAFT MULTISPECTRAL DIGITAL DATA.

    Science.gov (United States)

    Duval, Joseph S.

    1985-01-01

    Because the display and interpretation of satellite and aircraft remote-sensing data make extensive use of color film products, accurate reproduction of the color images is important. To achieve accurate color reproduction, the exposure and chemical processing of the film must be monitored and controlled. By using a combination of sensitometry, densitometry, and transfer functions that control film response curves, all of the different steps in the making of film images can be monitored and controlled. Because a sensitometer produces a calibrated exposure, the resulting step wedge can be used to monitor the chemical processing of the film. Step wedges put on film by image recording machines provide a means of monitoring the film exposure and color balance of the machines.

  19. [Features of the periodontal pathology at patients with metabolic syndrome].

    Science.gov (United States)

    Ermolaeva, L A; Shishkin, A N; Sheveleva, N A; Penkovoi, E A; Sheveleva, M A; Sokolovich, N A; Khabarova, O V; Mihailova, E S

    2016-01-01

    The purpose of this article is to familiarize readers on the relationship between metabolic syndrome and periodontitis, as well as common pathogenetic processes underlying these diseases. The data of modern researches, devoted to the correlation of lesions of periodontal and systemic diseases associated with metabolic syndrome. In the article analyzed also the data of the original study of the interaction of periodontitis and metabolic syndrome, which also used special methods of examination like Doppler ultrasound microcirculatory vasculature of the periodontal tissues and ultrasound densitometry. The possible methods of diagnostics of a condition of periodontal tissues in patients with metabolic syndrome are considered. Conclusions about the relationship of each component of metabolic syndrome with periodontitis are made.

  20. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT

    International Nuclear Information System (INIS)

    Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio

    2012-01-01

    Background. Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. Purpose. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Material and Methods. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. Results. In three of six operator pairs and in one of two intra-operator pairs the Kendall t test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). Conclusion. The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent

  1. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT.

    Science.gov (United States)

    Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio

    2012-02-01

    Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. In three of six operator pairs and in one of two intra-operator pairs the Kendall τ test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent.

  2. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT

    Energy Technology Data Exchange (ETDEWEB)

    Mascalchi, Mario; Diciotti, Stefano (Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Florence (Italy)), Email: m.mascalchi@dfc.unifi.it; Sverzellati, Nicola (Department of Radiology, University of Parma, Parma (Italy)); Camiciottoli, Gianna (Department of Critical Care, University of Florence, Florence (Italy)); Ciccotosto, Cesareo (Division of Radiology, Arezzo Hospital, Arezzo (Italy)); Falaschi, Fabio (Second Division of Radiology, Cisanello Hospital, Azienda Ospedaliero Universitaria Pisana, Pisa (Italy)); Zompatori, Maurizio (Department of Radiology, S Orsola Hospital of Bologna, University of Bologna, Bologna (Italy))

    2012-02-15

    Background. Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. Purpose. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Material and Methods. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 +- 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. Results. In three of six operator pairs and in one of two intra-operator pairs the Kendall t test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). Conclusion. The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent

  3. Study of relation between Neck Shaft Angle (NSA and mineral density of the femoral head among old post menopausal women in east part of mazandaran province

    Directory of Open Access Journals (Sweden)

    Majid Malekzadeh Shafaroudi

    2016-09-01

    Full Text Available Background: Diversity in Proximal Femur Geometric Parameters (PFGPs will be led to frequency changes in hip fractures. The purpose of the present study is to investigate of the relation between Bone Mineral Density (BMD in proximal femur with Neck Shaft Angle (NSA in both of osteoporotic and normal groups among old postmenopausal women in eastern part of Mazandaran province as a appropriate indicator to predict hip fractures occurance. Materials and Methods: Among 5103 postmenopausal women reffered to bone densitometry center, for 221 postmenopausal women who had inclusion criteria to this study, simultaneously by using densitometry system and completing a standard questionnaire, history of disease and demographic information including body mass index (BMI were recorded for each patient. Obtained information from densitometers was analyzed by the statistical software SPSS version 16 and Pearson correlation coefficient test was used. Results: Geometric parameters of 221 post-menopausal women aged 50 to 60 were analyzed. The mean of neck shaft angle (NSA were recorded for osteoporotic group 121.55 and for control group 121.44. Pearson correlation coefficient t-test results showed a negative significant correlation between mineral density in the femoral neck in osteoporotic group and NSA (P<0.05. Considering the effect of weight and BMI in strength and bone density in the femoral neck, the mean of BMI and weight in osteoporotic group was lower compared to control group. Conclusion: according to the findings of this study, NSA is effective in predicting of the proximal femur BMD in osteoporotic group.

  4. Computed tomographic evaluation of pulmonary mass lesion in chest radiography

    International Nuclear Information System (INIS)

    Choe, Kyu Ok

    1984-01-01

    Until recently, solitary coin lesion of pulmonary disease has been a conspicuous problem in radiologic diagnosis. It is now well informed that CT has offered high resolution with its objective CT numbers to provide additional information in terms of anatomic and pathologic changes. Here by the aid of CT, the authors has retrospectively patients with various shape of round masses thus illustrating the advantage of it over conventional X-ray in diagnosis. 1. Total 53 patients, including 34 males and 19 females, aging between 19 to 76 years old with nodule or mass of any size ranging 1 to 13 cm in diameter were observed. 2. On plain chest X-ray they were identified where 50 patients has single round nodular or mass, only one had two masses which were ecchinococcal cysts, and the rest two had invisible lesions, only detected by CT. 3. With philips tomoscan 310, CT scan was taken 12 mm thicken slice during quiet respiration. Using the ROI cursor the average CT number of the central area was calculated 1.0 cm in side the outer border of the mass. 4. As a consequence of their pathologic features, they were itemized to 4 group as 36 solid, 9 cystic, 4 consolidative and 4 cavitary lesions. 5. Correct diagnosis of 3 cystic lesions, 4 diffuse calcification, 1 A-V malformation were available by CT densitometry. 6. By the aid of better resolution and additional cross-sectional orientation of CT, 3 extrapulmonary lesions, 3 segmental consolidations, 2 bronchocele, and 2 solitary metastasis, were helpful in diagnosis. 7. Also helpful in determining the extent of intrathoracic extent of bronchogenic carcinoma for the same reason but given clues were not more than the ordinary. 8. However, the limitation of the CT densitometry led to miss diagnosis of 3 examples of cystic vs.solid lesions, and CT density of noncalcified granuloma together with bronchogenic carcinoma, did not have a clear cut separation in between.

  5. Formulation of Oil-in-Water Cream from Mangosteen (Garcinia mangostana L. Pericarp Extract Preserved by Gamma Irradiation

    Directory of Open Access Journals (Sweden)

    E. Isabella

    2013-12-01

    Full Text Available The aim of this research was to formulate mangosteen (Garcinia mangostana L. pericarp extract into oil-in-water (O/W cream which stable and durable. In order to improve the shelf life durability of the formula, the irradiation of formula using gamma rays from cobalt-60 was done. The concentrations of extract were varied to 1, 2 and 3% and were irradiated by gamma rays with doses of 5, 7.5 and 10 kGy. Physicochemical and microbiological properties of these formulas were carried out for 90 days stored at 30 ± 2°C and 40 ± 2°C. It was found that both of physicochemical and microbiological properties of the formulas were changed by extract concentrations and after irradiation. The irradiated formulas with dose up to 7.5 kGy, which were stored at 30 ± 2°C and 40 ± 2°C, presented acceptable physicochemical and microbiological stability for at least 90 days. Analysis by TLC (Thin Layer Chromatography-densitometry to study decomposition of G. mangostana pericarp extract cream formulas was carried out 24 h after preparation and 90 day after storage. The result of TLC-densitometry analysis showed that G. mangostana pericarp extract in the cream formulas did not develope significant decomposition after 90 days of storage. Decontamination dose for all formulas was found to be about 7.5 kGy. At this condition, the bacteria and mold-yeast have been killed, without reducing the antioxidant activity

  6. Cough-induced rib fractures.

    Science.gov (United States)

    Hanak, Viktor; Hartman, Thomas E; Ryu, Jay H

    2005-07-01

    To define the demographic, clinical, and radiological features of patients with cough-induced rib fractures and to assess potential risk factors. For this retrospective, single-center study, we identified all cases of cough-induced rib fractures diagnosed at the Mayo Clinic in Rochester, Minn, over a 9-year period between January 1, 1996, and January 31, 2005. Bone densitometry data from patients' medical records were analyzed, and T scores were used to classify patients into bone density categories. The mean +/- SD age of the 54 study patients at presentation was 55+/-17 years, and 42 patients (78%) were female. Patients presented with chest wall pain after onset of cough. Rib fracture was associated with chronic cough (> or =3 weeks' duration) in 85% of patients. Rib fractures were documented by chest radiography, rib radiography, computed tomography, or bone scan. Chest radiography had been performed in 52 patients and revealed rib fracture in 30 (58%). There were 112 fractured ribs in 54 patients. One half of patients had more than one fractured rib. Right-sided rib fractures alone were present in 17 patients (26 fractured ribs), left-sided in 23 patients (35 fractured ribs), and bilateral in 14 patients (51 fractured ribs). The most commonly fractured rib on both sides was rib 6. The fractures were most common at the lateral aspect of the rib cage. Bone densitometry was done in 26 patients and revealed osteopenia or osteoporosis in 17 (65%). Cough-induced rib fractures occur primarily in women with chronic cough. Middle ribs along the lateral aspect of the rib cage are affected most commonly. Although reduced bone density is likely a risk factor, cough-induced rib fractures can occur in the presence of normal bone density.

  7. Use of coffee (Coffea arabica pulp for the production of briquettes and pellets for heat generation

    Directory of Open Access Journals (Sweden)

    Robert Cubero-Abarca

    2014-10-01

    Full Text Available Coffee bean (Coffea arabica processing generates high amount of residues that are sources of environmental pollution. Therefore, an appropriate solution is needed. The objective of this study was to determine the potential of coffee pulp to produce briquettes and pellets. The study included pulp drying (using air, solar and hot air methods; the production of briquettes and pellets; the evaluation of their energy, physical and mechanical properties; and the evaluation of pellet quality using X-ray densitometry. The results showed that the pulp presented an initial moisture content of 90%, resulting in drying times of 699, 308 and 55 hours for air, solar and hot air drying, respectively, and the calorific values of the pellets and briquettes were 12,501 kJ kg-1 and 11,591 kJ kg-1, respectively. The ash content was 8.68% for the briquettes and 6.74% for the pellets. The density of the briquettes was 1,110 kg m-3, compared with 1,300 kg m-3 for the pellets. The apparent densities were 1,000 kg m-3 and 600 kg m-3 for the briquettes and pellets, respectively, and the water absorptions by the briquettes were 7.90% and 8.10% by the pellets. The maximum horizontal compression effort was 26.86 kg cm-2, measured in the pellets, compared with 4.52 kg cm-2 in the briquettes. The maximum horizontal load was 93.24 kg, measured in the briquettes, compared with 33.50 kg in the pellets. The value of the pellet durability test was 75.54%. X-ray densitometry showed that the pellet was uniform and a few cracks were observed on the pellet surface.

  8. The selective neurotoxin DSP-4 impairs the noradrenergic projections from the locus coeruleus to the inferior colliculus in rats.

    Directory of Open Access Journals (Sweden)

    Sebastián eHormigo

    2012-06-01

    Full Text Available The inferior colliculus (IC and the locus coeruleus (LC are two midbrain nuclei that integrate multimodal information and play a major role in novelty detection to elicit an orienting response. Despite the reciprocal connections between these two structures, the projection pattern and target areas of the LC within the subdivisions of the rat IC are still unknown. Here, we used tract-tracing approaches combined with immunohistochemistry, densitometry and confocal microscopy analysis to describe a projection from the LC to the IC. Biotinylated dextran amine (BDA injections into the LC showed that the LC-IC projection is mainly ipsilateral (90% and reaches, to a major extent, the dorsal and lateral part of the IC and the intercollicular commissure. Additionally, some LC fibers extend into the central nucleus of the IC. The neurochemical nature of this projection is noradrenergic, given that tyrosine hydroxylase (TH and dopamine beta hydroxylase (DBH colocalize with the BDA-labeled fibers from the LC. To determine the total field of the LC innervations in the IC, we destroyed the LC neurons and fibers using a highly selective neurotoxin, DSP-4, and then studied the distribution and density of TH- and DBH-immunolabeled axons in the IC. In the DSP-4 treated animals, the number of axonal fibers immunolabeled for TH and DBH were deeply decreased throughout the entire rostrocaudal extent of the IC and its subdivisions compared to controls. Our densitometry results showed that the IC receives up to 97% of its noradrenergic innervations from the LC neurons and only 3% from non-coeruleus neurons. Our results also indicate that TH immunoreactivity in the IC was less impaired than the immunoreactivity for DBH after DSP-4 administration. This is consistent with the existence of an important dopaminergic projection from the substantia nigra to the IC. In conclusion, our study demonstrates and quantifies the noradrenergic projection from the LC to the IC and its

  9. Advanced glycation end product (AGE) modified proteins in tears of diabetic patients.

    Science.gov (United States)

    Zhao, Zhenjun; Liu, Jingfang; Shi, Bingyin; He, Shuixiang; Yao, Xiaoli; Willcox, Mark D P

    2010-08-11

    High glucose level in diabetic patients may lead to advanced glycation end product (AGE) modified proteins. This study investigated AGE modified proteins in tears and compared their levels in diabetic patients (DM) with non-diabetic controls (CTL). Basal tears were collected from DM with (DR) or without (DNR) retinopathy and CTL. Total AGE modified proteins were detected quantitatively by a dot immunobinding assay. The AGE modified proteins were separated in 1D- and 2D-SDS gels and detected by western-blotting. The individual AGE modified proteins were also compared between groups using densitometry. Compared with the CTL group, tear concentrations of AGE modified proteins were significantly elevated in DR and DNR groups. The concentration of AGE modified proteins in diabetic tears were positively correlated with AGE modified hemoglobin (HbA1c) and postprandial blood glucose level (PBG). Western blotting of AGE modified proteins from 1D-SDS gels showed several bands, the major one at around 60 kDa. The intensities of AGE modified protein bands were higher in DM tears than in CTL tears. Western blotting from 2D-SDS gels showed a strongly stained horizontal strip, which corresponded to the major band in 1D-SDS gels. Most of the other AGE modified protein species were within molecular weight of 30-60 kDa, PI 5.2-7.0. Densitometry analysis demonstrated several AGE modified proteins were elevated in DR or DNR tears. Total and some individual AGE modified proteins were elevated in DM tears. AGE modified proteins in tears may be used as biomarkers to diagnose diabetes and/or diabetic retinopathy.

  10. Effects of Curcumin on Bone Loss and Biochemical Markers of Bone Turnover in Patients with Spinal Cord Injury.

    Science.gov (United States)

    Hatefi, Masoud; Ahmadi, Mohammad Reza Hafezi; Rahmani, Asghar; Dastjerdi, Masoud Moghadas; Asadollahi, Khairollah

    2018-06-01

    Osteoporosis is one of the most common problems of patients with spinal cord injuries (SCIs). The current study aimed to evaluate the antiosteoporotic effects of curcumin on densitometry parameters and biomarkers of bone turnovers among patients with SCI. The current controlled clinical trial was conducted among 100 patients with SCI referred to an outpatient clinic of rehabilitation in Ilam City, Iran, in 2013-2015. The intervention group received 110/mg/kg/day curcumin for 6 months and the control group received placebo. Bone mineral density (BMD) was measured in all patients. The level of procollagen type I N-terminal propeptide, serum carboxy-terminal telopeptide of type I collagen, osteocalcin, and bone-specific alkaline phosphates were compared before and after study. BMD indicators of lumbar, femoral neck, and total hip in the control group significantly decreased compared with the beginning of study. However, in the curcumin group, a significant increase was observed in BMD indicators of lumbar, femoral neck, and hip at the end of study compared with the beginning. There was also a significant difference between interventional and control groups for the mean BMD of femoral neck and hip at the end of study (0.718 ± 0.002 g/cm 2 vs. 0.712 ± 0.003 g/cm 2 and 0.742 ± 0.031 g/cm 2 vs. 0.692 ± 0.016 g/cm 2 , respectively). Curcumin, via modulation of densitometry indices and bone resorption markers, showed inhibitory effects on the process of osteoporosis. Treatment with curcumin was significantly associated with a decrease in the osteoporosis progression and bone turnover markers of patients with SCI after 6 months. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Effect of post crosslinking haze on the repeatability of Scheimpflug-based and slit-scanning imaging devices

    Directory of Open Access Journals (Sweden)

    Rohit Shetty

    2017-01-01

    Full Text Available Purpose: The aim of this study was to analyze the effect of postcollagen crosslinking (CXL haze on the measurement and repeatability of pachymetry and mean keratometry (Km of four corneal topographers. Materials and Methods: Sixty eyes of sixty patients with progressive keratoconus who had undergone accelerated CXL (ACXL underwent imaging with a scanning slit imaging device (Orbscan II and three Scheimpflug imaging devices (Pentacam HR, Sirius, and Galilei. Post-ACXL haze was measured using the densitometry software on the Pentacam HR. Readings of the thinnest corneal thickness (TCT and Km from three scans of each device were analyzed. Effect of haze on the repeatability of TCT and Km measurements was evaluated using regression models. Repeatability was assessed by coefficient of variation. Results: Corneal densitometry in different zones affected the repeatability of TCT measurement of Orbscan (P < 0.05 significantly but not the repeatability of TCT with Pentacam HR and Sirius (P = 0.03 and 0.05, respectively. Km values were affected by haze when measured with the Pentacam HR (P < 0.05. The repeatability of Km readings for all devices was unaffected by haze. In the anterior 0–2 mm and 2–6 mm zone, TCT (P = 0.43 and 0.45, respectively, Km values (P = 0.4 and 0.6, respectively, repeatability of TCT (P = 0.1 in both zones, and Km (P = 0.5 and 0.1, respectively with Galilei were found to be the most reliable. Conclusion: Galilei measurements appear to be least affected by post-ACXL haze when compared with other devices. Hence, topography measurements in the presence of haze need to be interpreted with caution.

  12. Quantitative digital radiography with two dimensional flat panels

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Darboux, M.

    2003-01-01

    Purpose: Attenuation law relates radiographic images to irradiated object thickness and chemical composition. Film radiography exploits qualitatively this property for diagnosis. Digital radiographic flat panels present large dynamic range, reproducibility and linearity properties which open the gate for quantification. We will present, through two applications (mammography and bone densitometry), an approach to extract quantitative information from digital 2D radiographs. Material and method: The main difficulty for quantification is X-rays scatter, which superimposes to acquisition data. Because of multiple scatterings and 3D geometry dependence, it cannot be directly exploited through an exact analytical model. Therefore we have developed an approach for its estimation and subtraction from medical radiographs, based on approximations and derivations of analytical models of scatter formation in human tissues. Results: In digital mammography, the objective is to build a map of the glandular tissue thickness. Its separation from fat tissue is based on two equations: height of compression and attenuation. This last equation needs X-Rays scatter correction. In bone densitometry, physicians look for quantitative bone mineral density. Today, clinical DEXA systems use collimated single or linear detectors to eliminate scatter. This scanning technology induces poor image quality. By applying our scatter correction approach, we have developed a bone densitometer using a digital flat panel (Lexxos, DMS). It provides with accurate and reproducible measurements while presenting radiological image quality. Conclusion: These applications show how information processing, and especially X-Rays scatter processing, enables to extract quantitative information from digital radiographs. This approach, associated to Computer Aided Diagnosis algorithms or reconstructions algorithms, gives access to useful information for diagnosis. (author)

  13. CONSENSUS STATEMENT BY THE AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY ON THE QUALITY OF DXA SCANS AND REPORTS.

    Science.gov (United States)

    Licata, Angelo A; Binkley, Neil; Petak, Steven M; Camacho, Pauline M

    2018-02-01

    High-quality dual-energy X-ray absorptiometry (DXA) scans are necessary for accurate diagnosis of osteoporosis and monitoring of therapy; however, DXA scan reports may contain errors that cause confusion about diagnosis and treatment. This American Association of Clinical Endocrinologists/American College of Endocrinology consensus statement was generated to draw attention to many common technical problems affecting DXA report conclusions and provide guidance on how to address them to ensure that patients receive appropriate osteoporosis care. The DXA Writing Committee developed a consensus based on discussion and evaluation of available literature related to osteoporosis and osteodensitometry. Technical errors may include errors in scan acquisition and/or analysis, leading to incorrect diagnosis and reporting of change over time. Although the International Society for Clinical Densitometry advocates training for technologists and medical interpreters to help eliminate these problems, many lack skill in this technology. Suspicion that reports are wrong arises when clinical history is not compatible with scan interpretation (e.g., dramatic increase/decrease in a short period of time; declines in previously stable bone density after years of treatment), when different scanners are used, or when inconsistent anatomic sites are used for monitoring the response to therapy. Understanding the concept of least significant change will minimize erroneous conclusions about changes in bone density. Clinicians must develop the skills to differentiate technical problems, which confound reports, from real biological changes. We recommend that clinicians review actual scan images and data, instead of relying solely on the impression of the report, to pinpoint errors and accurately interpret DXA scan images. AACE = American Association of Clinical Endocrinologists; BMC = bone mineral content; BMD = bone mineral density; DXA = dual-energy X-ray absorptiometry; ISCD = International

  14. BONE MINERAL DENSITY IN PHYSICALLY ACTIVE WOMEN ASSESSED BY ULTRASOUND DESINTOMETRY

    Directory of Open Access Journals (Sweden)

    Ana Marijanac

    2015-05-01

    Full Text Available Osteoporosis is a disease characterized by low bone mass and density. Physical activity has a positive effect on bone tissue, and it is recommended to prevent bone loss which comes with age. Methods: In purpose of determining bone mineral density in women who are physically active we examined 35 women divided into two groups – subjects who are premenopausal (n=20, 43.52 ± 7.56 years, and subjects who are postmenopausal (n=15, 55.89 ± 5.48. The subjects exercised Pilates method twice a week for one hour. Bone mineral density measurements were done by ultrasound densitometer „Sahara“ through the calcaneus. We get the data of the estimated bone density and T-score for right and left foot separate. Results: According to results premenopausal women have normal bone density, and postmenopausal values represent osteopenia, according to the WHO. There is no subjects who established osteoporosis. Discussion: Previous investigations have confirmed that physical activity is important for the preservation of the bone quality. Increasing steps, using simple everyday tasks, can prevent decrease in BMD in postmenopausal women (Muir et al., 2013, Ashe et al, 2008. There’s difference in the density of the calcaneus between physically active and those who are not, measured by ultrasound densitometry (Vainionpää et al, 2005. We use quantitative ultrasound densitometry to describe BMI of women who exercise Pilates and support the finding that physical activity is one of the ways that may prevent the BMD loss. These research was done as a part of long-term project entitled „Impact of physical activity of the working population“ which is co-financed by Provincial Secretariat for Science and Technological Development.

  15. Employing Response Surface Methodology for the Optimization of Ultrasound Assisted Extraction of Lutein and β-Carotene from Spinach

    Directory of Open Access Journals (Sweden)

    Ammar Altemimi

    2015-04-01

    Full Text Available The extraction of lutein and β-carotene from spinach (Spinacia oleracea L. leaves is important to the dietary supplement industry. A Box-Behnken design and response surface methodology (RSM were used to investigate the effect of process variables on the ultrasound-assisted extraction (UAE of lutein and β-carotene from spinach. Three independent variables, extraction temperature (°C, extraction power (% and extraction time (min were studied. Thin-layer chromatography (TLC followed by UV visualization and densitometry was used as a simple and rapid method for both identification and quantification of lutein and β-carotene during UAE. Methanol extracts of leaves from spinach and authentic standards of lutein and β-carotene were separated by normal-phase TLC with ethyl acetate-acetone (5:4 (v/v as the mobile phase. In this study, the combination of TLC, densitometry, and Box–Behnken with RSM methods were effective for the quantitative analysis of lutein and β-carotene from spinach extracts. The resulting quadratic polynomial models for optimizing lutein and β-carotene from spinach had high coefficients of determination of 0.96 and 0.94, respectively. The optimal UAE settings for output of lutein and β-carotene simultaneously from spinach extracts were an extraction temperature of 40 °C, extraction power of 40% (28 W/cm3 and extraction time of 16 min. The identity and purity of each TLC spot was measured using time-of-flight mass spectrometry. Therefore, UAE assisted extraction of carotenes from spinach can provide a source of lutein and β-carotene for the dietary supplement industry.

  16. Prevalence of low bone mineral density in children and adolescents with celiac disease under treatment

    Directory of Open Access Journals (Sweden)

    Maria Eugênia Farias Almeida Motta

    Full Text Available CONTEXT AND OBJECTIVE: Low bone mineral density may be a finding among children and adolescents with celiac disease, including those undergoing treatment with a gluten-free diet, but the data are contradictory. The aim of this study was to determine the frequency of bone mineral density abnormalities in patients on a gluten-free diet, considering age at diagnosis and duration of dietary treatment. DESIGN AND SETTING: Cross-sectional prevalence study at the Pediatric Gastroenterology Outpatient Clinic of Instituto Materno Infantil Professor Fernando Figueira. METHODS: Thirty-one patients over five years of age with celiac disease and on a gluten-free diet were enrolled. Bone mineral density (in g/cm² was measured in the lumbar spine and whole body using bone densitometry and categorized using the criteria of the International Society for Clinical Densitometry, i.e. low bone mineral density for chronological age < -2.0 Z-scores. Age at diagnosis and duration of dietary treatment were confirmed according to the date of starting the gluten-free diet. RESULTS: Low bone density for chronological age was present in 3/31 patients in the lumbar spine and 1/31 in the whole body (also with lumbar spine abnormality. At diagnosis, three patients with low bone mineral density for the chronological age were more than 7.6 years old. These patients had been on a gluten-free diet for six and seven months and 3.4 years. CONCLUSION: Pediatric patients with celiac disease on long-term treatment are at risk of low bone mineral density. Early diagnosis and long periods of gluten-free diet are directly implicated in bone density normalization.

  17. 30years of DXA technology innovations.

    Science.gov (United States)

    Glüer, Claus-C

    2017-11-01

    As the successor of Dual Photon Absorptiometry (DPA), Dual X-ray Absorptiometry (DXA) has seen 30years of continuous technological innovations. Implementation of measures for standardization and quality assurance made DXA a reliable and clinically useful approach. Its use in clinical multicenter drug studies in osteoporosis lead to general acceptance as the standard technique of bone densitometry. The limitations of DXA are well established. As a measure of areal bone mineral density (aBMD) it depends on bone size and is biased by overlaying soft tissue and calcified structures. To some extent these errors can be reduced by estimation of bone depth and/or lateral imaging. DXA based aBMD can be supplemented by additional information obtainable from DXA scans: geometric indices such as hip axis length or complex models like 2-D finite element analysis have been developed and tested. Given the drastic improvement in image quality current DXA scans can be used for Vertebral Fracture Analysis (VFA) or grading of Abdominal Aortic Calcifications. A textural measure, Trabecular Bone Score (TBS) provides independent information on fracture risk. DXA devices can also be used for assessments beyond bone density. Periprosthetic aBMD changes can be monitored to study the mechanical fitting of bone implants. Total body composition measurements are increasingly being used in studies on nutrition, obesity, and sarcopenia. 30years after its inception DXA is the undisputed standard imaging technique for the assessment of osteoporotic fracture risk with new applications beyond bone densitometry adding to its value. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Usefulness of the Trabecular Bone Score for assessing the risk of osteoporotic fracture.

    Science.gov (United States)

    Redondo, L; Puigoriol, E; Rodríguez, J R; Peris, P; Kanterewicz, E

    2018-04-01

    The trabecular bone score (TBS) is an imaging technique that assesses the condition of the trabecular microarchitecture. Preliminary results suggest that TBS, along with the bone mineral density assessment, could improve the calculation of the osteoporotic fracture risk. The aim of this study was to analyse TBS values and their relationship with the clinical characteristics, bone mineral density and history of fractures of a cohort of posmenopausal women. We analysed 2,257 posmenopausal women from the FRODOS cohort, which was created to determine the risk factors for osteoporotic fracture through a clinical survey and bone densitometry with vertebral morphometry. TBS was applied to the densitometry images. TBS values ≤1230 were considered indicative of degraded microarchitecture. We performed a simple and multiple linear regression to determine the factors associated with this index. The mean TBS value in L1-L4 was 1.203±0.121. Some 55.3% of the women showed values indicating degraded microarchitecture. In the multiple linear regression analysis, the factors associated with low TBS values were age, weight, height, spinal T-score, glucocorticoid treatment, presence of type 2 diabetes and a history of fractures due to frailty. TBS showed microarchitecture degradation values in the participants of the FRODOS cohort and was associated with anthropometric factors, low bone mineral density values, the presence of fractures, a history of type 2 diabetes mellitus and the use of glucocorticoids. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Medicina Interna (SEMI). All rights reserved.

  19. Soluble scute proteins of healthy and ill desert tortoises (Gopherus agassizii)

    Science.gov (United States)

    Homer, B.L.; Li, C.; Berry, K.H.; Denslow, N.D.; Jacobson, E.R.; Sawyer, R.H.; Williams, J.E.

    2001-01-01

    Objectives - To characterize protein composition of shell scute of desert tortoises and to determine whether detectable differences could be used to identify healthy tortoises from tortoises with certain illnesses. Animals - 20 desert tortoises. Procedures - Complete postmortem examinations were performed on all tortoises. Plastron scute proteins were solubilized, scute proteins were separated by use of sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), and proteins were analyzed, using densitometry. Two-dimensional immobilized pH gradient-PAGE (2D IPG-PAGE) and immunoblot analysis, using polyclonal antisera to chicken-feather ?? keratin and to alligator-scale ?? keratin, were conducted on representative samples. The 14-kd proteins were analyzed for amino acid composition. Results - The SDS-PAGE and densitometry revealed 7 distinct bands, each with a mean relative protein concentration of > 1 %, ranging from 8 to 47 kd, and a major protein component of approximately 14 kd that constituted up to 75% of the scute protein. The 2D IPG-PAGE revealed additional distinct 62-and 68-kd protein bands. On immunoblot analysis, the 14-, 32-, and 45-kd proteins reacted with both antisera. The 14-kd proteins had an amino acid composition similar to that of chicken ?? keratins. There was a substantial difference in the percentage of the major 14-kd proteins from scute of ill tortoises with normal appearing shells, compared with 14-kd proteins of healthy tortoises. Conclusions and Clinical Relevance - The major protein components of shell scute of desert tortoises have amino acid composition and antigenic features of ?? keratins. Scute protein composition may be altered in tortoises with certain systemic illnesses.

  20. Immunoaffinity column clean-up and thin layer chromatography for determination of ochratoxin A in green coffee.

    Science.gov (United States)

    Santos, E A; Vargas, E A

    2002-05-01

    An immunoaffinity clean-up-based method for determining ochratoxin A (OTA) in green coffee aiming at one-dimensional thin layer chromatography (TLC) analysis was established. OTA was extracted with a mixture of methanol and aqueous sodium hydrogen carbonate solution, purified through an immunoaffinity column, separated on normal or reversed-phase (RP) TLC plates and detected and quantified by visual and densitometric analysis. The linear equation of the standard calibration curve by densitometric analysis gave R(2) > 0.999 (0.04-84 ng). The mean recovery (R) of OTA from spiked samples (1.8-109 microg kg(-1)) by densitometric and visual analyses were 98.4 and 103.8%, respectively. The relative standard deviations (RSD) for densitometric and visual analysis varied from 1.1 to 24.9% and from 0.0 to 18.8%, respectively. The RSD for naturally contaminated samples by densitometry (three levels of contamination, n = 3) varied from 11.1 to 18.1%. The correlation (R(2)) between high-performance liquid chromatography (HPLC) and densitometry, and between visual and densitometric analysis for spiked samples were > 0.99. The limit of detection (LOD) of the method was 0.5 microg kg(-1) for normal TLC. Toluene-ethyl acetate-88% formic acid (6:3:1 v/v/v) and acetonitrile-methanol-water-glacial acetic acid (35:35:29:10 v/v/v/v) were regarded as the suitable TLC solvents for eluting both standards and samples on normal and RP TLC plates, respectively. Toluene-acetic acid (99:1 v/v) was chosen as the spotting solvent among several others for giving the best sensitivity and resolution of OTA on TLC plates as well as the best recovery of OTA from standard and sample extract residues. Preliminary studies were carried out to investigate the reuse of the immunoaffinity column and the interference of caffeine in the OTA recovery.

  1. Test and evaluation of the in-line plutonium solution K-absorption-edge densitometer at the Savannah River Plant. Phase I. Off-line testing results

    International Nuclear Information System (INIS)

    Smith, H.A. Jr.; Marks, T.; Johnson, S.S.

    1982-04-01

    An in-line, plutonium-solution, K-edge absorption densitometer has been developed at Los Alamos and is currently undergoing test and evaluation at the Savannah River Plant (SRP). The first phase of the test and evaluation (off-line instrument calibration and solution assays) was completed, and preparations are under way to install the instrument in-line, as soon as process schedules permit. Calibration data in the design concentration range of 25 to 40 g Pu/L demonstrate routine achievement of densitometry assay precisions of 0.5% or better in 40 min. Plutonium assays at concentrations outside the calibration range were investigated in an effort to define better the limitations of the instrument and address other possible assay situations at SRP. Densitometry precisions obtained for 40-min assays range from 3% to 5 g Pu/L down to 0.4% at 70 g Pu/L. At higher plutonium concentrations, the precision deteriorated due to increasing gamma-ray absorption by the solution. In addition, with actinide concentrations above approximately 100 g/L, the assay accuracy also suffered because of enhanced small-angle scattering effects in the large sample cell. Measurements on mixed U/Pu solutions demonstrated the feasibility of accurate plutonium assays with correction for the large uranium matrix contributions being determined from the measurement data. The 239 240 Pu weight fractions and 241 Pu/ 239 Pu and 238 Pu/ 239 Pu isotopic ratios can be determined. In a mockup of the in-line solution plumbing system, all assay sequences, error conditions, and interlock criteria were exercised and verified to be working properly

  2. Osteoporose Osteoporosis

    Directory of Open Access Journals (Sweden)

    Julio Cesar Gali

    2001-06-01

    Full Text Available A osteoporose é uma doença ósteo-metabólica que atinge especialmente mulheres após a menopausa. Segundo a Organização Mundial de Saúde 1/3 das mulheres brancas acima dos 65 anos são portadoras de osteoporose. Entretanto estima-se que um homem branco de 60 anos tenha 25 % de chance de ter uma fratura osteoporótica. O diagnóstico e planejamento terapêutico são baseados na densitometria óssea e na dosagem laboratorial dos marcadores de formação e reabsorção óssea. A densitometria também é o melhor preditor de fraturas. Os medicamentos atualmente disponíveis atuam mais na inibição da reabsorção óssea. A principal forma de tratamento da osteoporose é a prevenção: deve-se evitar o fumo; álcool e café devem ser consumidos com moderação; a atividade física e ingestão adequada de cálcio são fundamentais; o treinamento proprioceptivo pode colaborar para prevenir quedas e, conseqüentemente, as fraturas.Osteoporosis is an osteometabolic disease affecting mainly postmenopausal women. According to the World Health Organization, 1/3 of older than 65 white women are affected by osteoporosis. Notwithstanding, the estimates say that 60-year old white males have a 25% chance of osteoporotic fractures. Diagnosis and the therapeutic design are based on bone densitometry and laboratory determinations of formation and bone reabsorption markers. Densitometry is the best fracture predictor. Currently available drugs act inhibiting bone reabsorption. The main form of treatment of osteoporosis is prevention: smoking must be avoided; alcohol and coffee drinking must be moderate; physical activity and adequate calcium intake are fundamental; proprioceptive training can prevent falls and, consequently, fractures.

  3. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    New densitometer installation requires cross-calibration for accurate longitudinal assessment. When replacing a unit with the same model, the International Society for Clinical Densitometry recommends cross-calibrating by scanning phantoms 10 times on each instrument and states that spine bone mineral density (BMD) should be within 1%, whereas total body lean, fat, and %fat mass should be within 2% of the prior instrument. However, there is limited validation that these recommendations provide adequate total body cross-calibration. Here, we report a total body cross-calibration experience with phantoms and humans. Cross-calibration between an existing and new Lunar iDXA was performed using 3 encapsulated spine phantoms (GE [GE Lunar, Madison, WI], BioClinica [BioClinica Inc, Princeton, NJ], and Hologic [Hologic Inc, Bedford, MA]), 1 total body composition phantom (BioClinica), and 30 human volunteers. Thirty scans of each phantom and a total body scan of human volunteers were obtained on each instrument. All spine phantom BMD means were similar (within 1%; g/cm2 bias) between the existing and new dual-energy X-ray absorptiometry unit. The BioClinica body composition phantom (BBCP) BMD and bone mineral content (BMC) values were within 2% with biases of 0.005 g/cm2 and -3.4 g. However, lean and fat mass and %fat differed by 4.6%-7.7% with biases of +463 g, -496 g, and -2.8%, respectively. In vivo comparison supported BBCP data; BMD and BMC were within ∼2%, but lean and fat mass and %fat differed from 1.6% to 4.9% with biases of +833 g, -860 g, and -1.1%. As all body composition comparisons exceeded the recommended 2%, the new densitometer was recalibrated. After recalibration, in vivo bias was lower (g, respectively. Similarly, BBCP lean and fat agreement improved. In conclusion, the BBCP behaves similarly, but not identical, to human in vivo measurements for densitometer cross-calibration. Spine phantoms, despite good BMD and BMC agreement, did not detect

  4. Vitamin D and nutritional status are related to bone fractures in alcoholics.

    Science.gov (United States)

    González-Reimers, Emilio; Alvisa-Negrín, Julio; Santolaria-Fernández, Francisco; Candelaria Martín-González, M; Hernández-Betancor, Iván; Fernández-Rodríguez, Camino M; Viña-Rodríguez, J; González-Díaz, Antonieta

    2011-01-01

    Bone fractures are common in alcoholics. To analyse which factors (ethanol consumption; liver function impairment; bone densitometry; hormone changes; nutritional status, and disrupted social links and altered eating habits) are related to bone fractures in 90 alcoholic men admitted to our hospitalization unit because of organic problems. Bone homoeostasis-related hormones were measured in patients and age- and sex-matched controls. Whole-body densitometry was performed by a Hologic QDR-2000 (Waltham, MA, USA) densitometer, recording bone mineral density (BMD) and fat and lean mass; nutritional status and liver function were assessed. The presence of prevalent fractures was assessed by anamnesis and chest X-ray film. Forty-nine patients presented at least one fracture. We failed to find differences between patients with and without fractures regarding BMD parameters. Differences regarding fat mass were absent, but lean mass was lower among patients with bone fracture. The presence of fracture was significantly associated with impaired subjective nutritional evaluation (χ² = 5.79, P = 0.016), lower vitamin D levels (Z = 2.98, P = 0.003) and irregular eating habits (χ² = 5.32, P = 0.02). Reduced lean mass and fat mass, and altered eating habits were more prevalent among patients with only rib fractures (n = 36) than in patients with multiple fractures and/or fractures affecting other bones (n = 13). These last were more closely related to decompensated liver disease. Serum vitamin D levels showed a significant relationship with handgrip strength (ρ = 0.26, P = 0.023) and lean mass at different parts of the body, but not with fat mass. By logistic regression analysis, only vitamin D and subjective nutritional evaluation were significantly, independently related with fractures. Prevalent fractures are common among heavy alcoholics. Their presence is related more closely to nutritional status, lean mass and vitamin D levels than to BMD. Lean mass is more reduced

  5. A histerectomia simples realizada no menacme e a densidade mineral óssea da mulher na pós-menopausa Pre-menopausal simple hysterectomy and post-menopausal female bone mineral density

    Directory of Open Access Journals (Sweden)

    João Daniel Hobeika

    2002-12-01

    Full Text Available O objetivo foi avaliar a densidade mineral óssea de mulheres na pós-menopausa, com o antecedente de histerectomia com conservação ovariana bilateral, realizada no menacme, comparadas a um grupo de mulheres com menopausa natural, não histerectomizadas. Tratou-se de um estudo de corte transversal, com trinta mulheres na pós-menopausa e histerectomizadas no menacme e 102 mulheres menopausadas naturalmente, comparando-se as respectivas densitometrias ósseas, em nível do fêmur e coluna lombar. A análise mostrou que as variáveis idade e índice de massa corporal estavam fortemente associadas à densidade mineral óssea do fêmur e da coluna lombar, sendo o índice de massa corporal diretamente e a idade inversamente associados. Posteriormente, as trinta mulheres histerectomizadas, foram pareadas por idade e índice de massa corporal, com trinta mulheres não-histerectomizadas, não apresentando diferenças estatisticamente significantes da densidade mineral óssea. Esses resultados sugerem que a histerectomia com conservação ovariana bilateral, realizada em mulheres no menacme, não parece ocasionar redução adicional da massa óssea, quando avaliadas na pós-menopausa.This study aimed to evaluate the bone mineral density (BMD of post-menopausal women with previous pre-menopausal hysterectomy including bilateral ovarian conservation compared to a group of non-hysterectomized women with natural menopause. Data from a cross-sectional study of 30 pre-menopausally hysterectomized women evaluated in the post-menopause were compared with 102 naturally post-menopausal women, analyzing their respective bone densitometry, measuring the femoral and lumbar spinal BMD. Multiple regression analysis of the 132 women showed that age and body mass index (BMI were heavily associated with femoral and lumbar spinal BMD, BMI directly associated, and age inversely associated with BMD. In addition, 30 hysterectomized women were matched by age and BMI to the

  6. Pulmonary nodule characterization: A comparison of conventional with quantitative and visual semi-quantitative analyses using contrast enhancement maps

    International Nuclear Information System (INIS)

    Petkovska, Iva; Shah, Sumit K.; McNitt-Gray, Michael F.; Goldin, Jonathan G.; Brown, Matthew S.; Kim, Hyun J.; Brown, Kathleen; Aberle, Denise R.

    2006-01-01

    Purpose: To determine whether conventional nodule densitometry or analysis based on contrast enhancement maps of indeterminate lung nodules imaged with contrast-enhanced CT can distinguish benign from malignant lung nodules. Materials and method: Thin section, contrast-enhanced CT (baseline, and post-contrast series acquired at 45, 90,180, and 360 s) was performed on 29 patients with indeterminate lung nodules (14 benign, 15 malignant). A thoracic radiologist identified the boundary of each nodule using semi-automated contouring to form a 3D region-of-interest (ROI) on each image series. The post-contrast series having the maximum mean enhancement was then volumetrically registered to the baseline series. The two series were subtracted volumetrically and the subtracted voxels were quantized into seven color-coded bins, forming a contrast enhancement map (CEM). Conventional nodule densitometry was performed to obtain the maximum difference in mean enhancement values for each nodule from a circular ROI. Three thoracic radiologists performed visual semi-quantitative analysis of each nodule, scoring each map for: (a) magnitude and (b) heterogeneity of enhancement throughout the entire volume of the nodule on a five-point scale. Receiver operator characteristic (ROC) analysis was conducted on these features to evaluate their diagnostic efficacy. Finally, 14 quantitative texture features were calculated for each map. A statistical analysis was performed to combine the 14 texture features to a single factor. ROC analysis of the derived aggregate factor was done as an indicator of malignancy. All features were analyzed for differences between benign and malignant nodules. Results: Using 15 HU as a threshold, 93% (14/15) of malignant and 79% (11/14) of benign nodules demonstrated enhancement. The ROC curve when higher values of enhancement indicate malignancy was generated and area under the curve (AUC) was 0.76. The visually scored magnitude of enhancement was found to be

  7. Dual-energy imaging of bone marrow edema on a dedicated multi-source cone-beam CT system for the extremities

    Science.gov (United States)

    Zbijewski, W.; Sisniega, A.; Stayman, J. W.; Thawait, G.; Packard, N.; Yorkston, J.; Demehri, S.; Fritz, J.; Siewerdsen, J. H.

    2015-03-01

    Purpose: Arthritis and bone trauma are often accompanied by bone marrow edema (BME). BME is challenging to detect in CT due to the overlaying trabecular structure but can be visualized using dual-energy (DE) techniques to discriminate water and fat. We investigate the feasibility of DE imaging of BME on a dedicated flat-panel detector (FPD) extremities cone-beam CT (CBCT) with a unique x-ray tube with three longitudinally mounted sources. Methods: Simulations involved a digital BME knee phantom imaged with a 60 kVp low-energy beam (LE) and 105 kVp high-energy beam (HE) (+0.25 mm Ag filter). Experiments were also performed on a test-bench with a Varian 4030CB FPD using the same beam energies as the simulation study. A three-source configuration was implemented with x-ray sources distributed along the longitudinal axis and DE CBCT acquisition in which the superior and inferior sources operate at HE (and collect half of the projection angles each) and the central source operates at LE. Three-source DE CBCT was compared to a double-scan, single-source orbit. Experiments were performed with a wrist phantom containing a 50 mg/ml densitometry insert submerged in alcohol (simulating fat) with drilled trabeculae down to ~1 mm to emulate the trabecular matrix. Reconstruction-based three-material decomposition of fat, soft tissue, and bone was performed. Results: For a low-dose scan (36 mAs in the HE and LE data), DE CBCT achieved combined accuracy of ~0.80 for a pattern of BME spherical lesions ranging 2.5 - 10 mm diameter in the knee phantom. The accuracy increased to ~0.90 for a 360 mAs scan. Excellent DE discrimination of the base materials was achieved in the experiments. Approximately 80% of the alcohol (fat) voxels in the trabecular phantom was properly identified both for single and 3-source acquisitions, indicating the ability to detect edemous tissue (water-equivalent plastic in the body of the densitometry insert) from the fat inside the trabecular matrix

  8. Study of vitamin D status of rheumatoid arthritis patients Rationale and design of a cross-sectional study by the osteoporosis and metabolic bone diseases study group of the Italian Society of Rheumatology (SIR

    Directory of Open Access Journals (Sweden)

    M. Antonelli

    2011-09-01

    Full Text Available The fundamental role of Vitamin D has been long known in regulating calcium homeostasis and bone metabolism. An increased contribution of Vitamin D was recently described in association with a lower incidence of Rheumatoid Arthritis (RA. This must not be surprising, as the immunomodulating effects of Vitamin D are clear, which have been attributed protective effects in autoimmune disorders such as some chronic inflammatory bowel diseases, multiple sclerosis and type I diabetes. An interaction was suggested between Vitamin D metabolism and inflammation indexes through mediation of TNF-a which is also especially involved in osteoclastic resorption and therefore in bone loss processes. Some preliminary data would indicate an association between seasonal changes of Vitamin D serum levels, latitude and disease activity (DAS28 in RA patients. Consequently, the Osteoporosis and Metabolic Bone Diseases Study Group of SIR believes that there are grounded reasons for assessing the Vitamin D status of RA patients in order to investigate whether this is to be related to physiopathological and clinical aspects of disease other than those of bone involvement. Primary end point of the study will be to assess the levels of 25 OH Vitamin D in RA patients. Secondary endpoints will include correlation with disease activity, densitometry values and bone turnover. The cross-sectional study will enrol patients of both sex genders, age ranging between 30 and 75 years according to the 1988 ACR criteria, onset of symptoms at least 2 years prior to study enrollment. Patients will be excluded suffering from osteometabolic diseases, liver and kidney insufficiency and those administered Vitamin D boli in the previous 12 months. Disease activity will be evaluated with the HAQ. Haematochemical tests and femoral and lumbar bone densitometry will be performed, unless recently undergone by patients. Blood levels of 25 OH C Vitamin D and PHT and of the two bone remodeling markers

  9. Avaliação clínica, radiográfica e laboratorial de pacientes com osteogênese imperfeita Clinical, radiographic and laboratory evaluation of patients with osteogenesis imperfecta

    Directory of Open Access Journals (Sweden)

    Cláudio Santili

    2005-08-01

    Full Text Available OBJETIVOS: A osteogênese imperfeita (OI é uma doença genética, caracterizando-se por alterações no colágeno do tipo I, que determinam um espectro amplo de alterações clínicas, como a dentinogênese imperfeita e escleras azuladas. O objetivo deste estudo é estabelecer uma correlação prática no diagnóstico diferencial intergrupos dentro da classificação de Sillence et al. (1979. MÉTODOS: Foram avaliados 22 pacientes mediante critérios clínicos e radiográficos. Após, a subdivisão de acordo com os tipos de Sillence et al. (1979, os pacientes foram também submetidos à avaliação laboratorial e à densitometria óssea. RESULTADOS: Os dados significantes para diferenciação entre os tipos da doença foram a estatura, o número total de fraturas por indivíduo e a densitometria óssea. O cálcio sérico não diferencia os tipos da doença. CONCLUSÕES: Características como a deambulação, a estatura e a densitometria óssea podem auxiliar na diferenciação entre os subtipos dos portadores da doença, repercutindo diretamente no estabelecimento do seu prognóstico.BACKGROUND: Osteogenesis imperfecta is a genetic disorder characterized by defects in type I collagen. The main symptom is bone fragility and susceptibility to fractures. Other clinical findings are dentinogenesis imperfecta, blue sclera, early deafness and joint laxity. The purpose of this paper is to establish a practical relationship of the clinical differences between the Sillence's groups. METHODS: 22 patients were classified according to Sillence et al criteria and submitted to laboratory tests including blood calcium level and bone densitometry. RESULTS: All clinical and laboratory differences were discussed in the text. CONCLUSIONS: Differences such as results that were found in walking ability, height and bone densitometry were significant and may help to classify patients and to establish prognosis.

  10. Ductal carcinoma in situ of the breast (DCIS) with heterogeneity of nuclear grade: prognostic effects of quantitative nuclear assessment

    International Nuclear Information System (INIS)

    Chapman, Judith-Anne W; Miller, Naomi A; Lickley, H Lavina A; Qian, Jin; Christens-Barry, William A; Fu, Yuejiao; Yuan, Yan; Axelrod, David E

    2007-01-01

    Previously, 50% of patients with breast ductal carcinoma in situ (DCIS) had more than one nuclear grade, and neither worst nor predominant nuclear grade was significantly associated with development of invasive carcinoma. Here, we used image analysis in addition to histologic evaluation to determine if quantification of nuclear features could provide additional prognostic information and hence impact prognostic assessments. Nuclear image features were extracted from about 200 nuclei of each of 80 patients with DCIS who underwent lumpectomy alone, and received no adjuvant systemic therapy. Nuclear images were obtained from 20 representative nuclei per duct, from each of a group of 5 ducts, in two separate fields, for 10 ducts. Reproducibility of image analysis features was determined, as was the ability of features to discriminate between nuclear grades. Patient information was available about clinical factors (age and method of DCIS detection), pathologic factors (DCIS size, nuclear grade, margin size, and amount of parenchymal involvement), and 39 image features (morphology, densitometry, and texture). The prognostic effects of these factors and features on the development of invasive breast cancer were examined with Cox step-wise multivariate regression. Duplicate measurements were similar for 89.7% to 97.4% of assessed image features. For the pooled assessment with ~200 nuclei per patient, a discriminant function with one densitometric and two texture features was significantly (p < 0.001) associated with nuclear grading, and provided 78.8% correct jackknifed classification of a patient's nuclear grade. In multivariate assessments, image analysis nuclear features had significant prognostic associations (p ≤ 0.05) with the development of invasive breast cancer. Texture (difference entropy, p < 0.001; contrast, p < 0.001; peak transition probability, p = 0.01), densitometry (range density, p = 0.004), and measured margin (p = 0.05) were associated with

  11. STUDY OF EFFECTIVE TIME OF UNDILUTED FIXINGSOLUTIONS INLIGHTENING OF THE HIGH DENSITY PERIAPICAL RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2003-12-01

    Full Text Available Introduction: Dental radiographs are occationally too dark because of different reasons such as over exposure, high concen-tration of developing solution and over development. Different chemicals are used to lighten these radiographs. In this research the undiluted fixed solution for the first time are tested and efficiency time of this solution in reducing the density of dark radiographs were evaluated. Method: Use of a dry mandible containing some teeth and 98 E speed periapical radiographs were prepared as foolow: A film wasexposed with 0.4 S... as positive control (ideal. 97 films were exposed with 1.8 S (dark and unreadable. Out of 97, one radiograph kept as positive control and remaining films prepared for study. All of radiographs developed and fixed with automatic processor in the same conditio. Out of 96 dark radiograph, 3 was used for pilot study and inserted in the undiluted fixing solution in different time. (2.5, 3 and 3.5 hrs. The result of pilot study showed that aii3 radiographs showed reductionin density and radiographs with her reduction time was closest to positive control for density and diognostic quality and radiograph with 2.5 hrs reduction time and 3.5 hre became darker and lighter as compared to positive control. The remaining 93 high density radiographs were divided into 3 groups, 31 in each group (group 1,2 and 3 first group 2.5 hrs, second 3 hrs and the third group 3.5 hrs were kept in undiluted fixed solution. for this, disposable glasses were used and in each glass a radiograph were inserted. The research time was spring and the temperature was about 2609 (without coolant. Evaluation of radiographs: For evaluation of radiographs 2 methods were used: First method used was: Densitometry: By this method the density of total lightened radiographs, positive control and negative control were determined. Another method was determined diagnostic quality of radiographs visually by radiologists, throng this way: Special

  12. Survival Fraction at 2 Gy and γH2AX Expression Kinetics in Peripheral Blood Lymphocytes From Cancer Patients: Relationship With Acute Radiation-Induced Toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Pouliliou, Stamatia E. [Department of Radiotherapy/Oncology, Radiobiology and Radiopathology Unit, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Lialiaris, Theodoros S. [Department of Medical Genetics, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Dimitriou, Thespis [Department of Anatomy, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Giatromanolaki, Alexandra [Department of Pathology, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Papazoglou, Dimitrios [Department of Internal Medicine, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Pappa, Aglaia [Department of Molecular Biology and Genetics, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Pistevou, Kyriaki [Department of Radiotherapy/Oncology, Aristotle University of Thessalonica, Thessalonica (Greece); Kalamida, Dimitra [Department of Radiotherapy/Oncology, Radiobiology and Radiopathology Unit, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece); Koukourakis, Michael I., E-mail: targ@her.forthnet.gr [Department of Radiotherapy/Oncology, Radiobiology and Radiopathology Unit, School of Health Sciences, Democritus University of Thrace, Alexandroupolis (Greece)

    2015-07-01

    Purpose: Predictive assays for acute radiation toxicities would be clinically relevant in radiation oncology. We prospectively examined the predictive role of the survival fraction at 2 Gy (SF2) and of γH2AX (double-strand break [DSB] DNA marker) expression kinetics in peripheral blood mononuclear cells (PBMCs) from cancer patients before radiation therapy. Methods and Materials: SF2 was measured with Trypan Blue assay in the PBMCs from 89 cancer patients undergoing radiation therapy at 4 hours (SF2{sub [4h]}) and 24 hours (SF2{sub [24h]}) after ex vivo irradiation. Using Western blot analysis and band densitometry, we further assessed the expression of γH2AX in PBMC DNA at 0 hours, 30 minutes, and 4 hours (33 patients) and 0 hour, 4 hours, and 24 hours (56 patients), following ex vivo irradiation with 2 Gy. Appropriate ratios were used to characterize each patient, and these were retrospectively correlated with early radiation therapy toxicity grade. Results: The SF2{sub (4h)} was inversely correlated with the toxicity grade (P=.006). The γH2AX-ratio{sub (30min)} (band density of irradiated/non-irradiated cells at 30 minutes) revealed, similarly, a significant inverse association (P=.0001). The DSB DNA repair rate from 30 minutes to 4 hours, calculated as the relative RγH2AX-ratio (γH2AX-ratio{sub (4h)}/γH2AX-ratio{sub (30min)}) showed a significant direct association with high toxicity grade (P=.01). Conclusions: Our results suggest that SF2 is a significant radiation sensitivity index for patients undergoing radiation therapy. γH2AX Western blot densitometry analysis provided 2 important markers of normal tissue radiation sensitivity. Low γH2AX expression at 30 minutes was linked with high toxicity grade, suggesting that poor γH2AX repair activity within a time frame of 30 minutes after irradiation predicts for poor radiation tolerance. On the other hand, rapid γH2AX content restoration at 4 hours after irradiation, compatible with

  13. Survival Fraction at 2 Gy and γH2AX Expression Kinetics in Peripheral Blood Lymphocytes From Cancer Patients: Relationship With Acute Radiation-Induced Toxicities

    International Nuclear Information System (INIS)

    Pouliliou, Stamatia E.; Lialiaris, Theodoros S.; Dimitriou, Thespis; Giatromanolaki, Alexandra; Papazoglou, Dimitrios; Pappa, Aglaia; Pistevou, Kyriaki; Kalamida, Dimitra; Koukourakis, Michael I.

    2015-01-01

    Purpose: Predictive assays for acute radiation toxicities would be clinically relevant in radiation oncology. We prospectively examined the predictive role of the survival fraction at 2 Gy (SF2) and of γH2AX (double-strand break [DSB] DNA marker) expression kinetics in peripheral blood mononuclear cells (PBMCs) from cancer patients before radiation therapy. Methods and Materials: SF2 was measured with Trypan Blue assay in the PBMCs from 89 cancer patients undergoing radiation therapy at 4 hours (SF2 [4h] ) and 24 hours (SF2 [24h] ) after ex vivo irradiation. Using Western blot analysis and band densitometry, we further assessed the expression of γH2AX in PBMC DNA at 0 hours, 30 minutes, and 4 hours (33 patients) and 0 hour, 4 hours, and 24 hours (56 patients), following ex vivo irradiation with 2 Gy. Appropriate ratios were used to characterize each patient, and these were retrospectively correlated with early radiation therapy toxicity grade. Results: The SF2 (4h) was inversely correlated with the toxicity grade (P=.006). The γH2AX-ratio (30min) (band density of irradiated/non-irradiated cells at 30 minutes) revealed, similarly, a significant inverse association (P=.0001). The DSB DNA repair rate from 30 minutes to 4 hours, calculated as the relative RγH2AX-ratio (γH2AX-ratio (4h) /γH2AX-ratio (30min) ) showed a significant direct association with high toxicity grade (P=.01). Conclusions: Our results suggest that SF2 is a significant radiation sensitivity index for patients undergoing radiation therapy. γH2AX Western blot densitometry analysis provided 2 important markers of normal tissue radiation sensitivity. Low γH2AX expression at 30 minutes was linked with high toxicity grade, suggesting that poor γH2AX repair activity within a time frame of 30 minutes after irradiation predicts for poor radiation tolerance. On the other hand, rapid γH2AX content restoration at 4 hours after irradiation, compatible with efficient DSB repair ability

  14. Characterization of the dose perturbation in tissue by stents as a function of external beam energy

    International Nuclear Information System (INIS)

    Schell, M.C.; Rosenzweig, D.P.; Weaver, K.A.; Rubin, P.

    1997-01-01

    Purpose: External beam irradiation of coronary arteries was shown to be detrimental in an animal model for the prevention of neointimal hyperplasia in the presence of stents when orthovoltage x-ray beams are used. This present study investigated the effect of beam energy on the dose distribution in the wall of the artery as a function of energy in the presence of stents in order to ascertain the effect on the dose due to beam energy. Materials and Methods: 250 kVp x-rays and 6-MV x rays were used to irradiate a stent placed in an homogeneous phantom. Radiochromic film densitometry and Monte Carlo calculations were used to measure and to simulate the dose distribution in the proximity of the stent. Result: External beam irradiation was reported to not only fail to prevent neointimal hyperplasia, but actually accentuate the neointimal response to a prompt mechanical injury in the artery. The photoelectric effect, which dominates low-energy x-ray interactions, produces recoil electrons in the stent which enhance the dose surrounding intima. The photoelectrons generated in nickel and iron have an extremely short range in normal tissue, approximately 0.1 mm. Initial estimates of orthovoltage x-ray interactions with the stent indicate a dose enhancement in the orthovoltage range by a factor of 2 to 3 due to the rise in the photoelectric cross section in this energy range depending on the elemental composition of the stent. Film densitometry verifies this dose enhancement. The Monte Carlo calculations yield a dose enhancement and the dose fall off with distance from the stent when irradiated with orthovoltage x-rays. Conversely when the tissue and stent are irradiated with megavoltage x-rays, the dose enhancement in this region is a factor of 1.15 in close proximity to the stent and 1.0 at distances greater than 0.1 mm. 6-MV photon interactions in tissue and iron are predominantly through Compton scattering. The Compton effect is dependent on the electron density in the

  15. Localization by whole-body autoradiography of intact and fragmented radiolabeled antibodies in a metastatic human colonic cancer model

    International Nuclear Information System (INIS)

    Fand, Irwin; Sharkey, R.M.; Grundy, J.P.; Goldenberg, D.M.

    1992-01-01

    In this report, we have employed macroautoradiography to compare the tumor targeting of 125 I-labeled anti-carcinoembryonic antigen (CEA) MAb (NP-4) to 125 I-labeled anti-colon-specific antigen-p (CSAp) MAb (Mu-9) and their labeled F(ab') 2 and Fab' fragments, in nude mice each bearing large dorsal human colonic tumor xenografts, and small nodular tumors in the liver and lungs. Using intact MAbs (NP-4 and Mu-9), clearance of background radioactivity was delayed to 3-7 days post-treatment. Treatment with F(ab') 2 and Fab' fragments of both NP-4 and Mu-9 MAbs, however, promoted clearance of background 125 I-radioactivity which was well advanced by 6-24 h and complete by 24-48 h after injection. Localization of 125 I-radioactivity in large and micrometastatic tumor perimeters was the most characteristic uptake pattern observed for both intact and fragmented MAbs. Qualitative analysis of macroautoradiographic images and quantitative densitometry indicated that the higher tumor-to-blood ratios achieved with labeled F(ab') 2 and Fab' fragments at early time points, compared to labeled whole immunoglobulin, appeared to be more a function of rapid plasma clearance, tumor mass, location of xenografts and specific tumor growth patterns than increased tumor penetrance by lower molecular weight univalent and bivalent immune fragments. (Author)

  16. The Role of Concentration and Solvent Character in the Molecular Organization of Humic Acids

    Directory of Open Access Journals (Sweden)

    Martina Klučáková

    2016-10-01

    Full Text Available The molecular organization of humic acids in different aqueous solutions was studied over a wide concentration range (0.01–10 g·dm−3. Solutions of humic acids were prepared in three different media: NaOH, NaCl, and NaOH neutralized by HCl after dissolution of the humic sample. Potentiometry, conductometry, densitometry, and high resolution ultrasound spectrometry were used in order to investigate conformational changes in the humic systems. The molecular organization of humic acids in the studied systems could be divided into three concentration ranges. The rearrangements were observed at concentrations of ~0.02 g·dm−3 and ~1 g·dm−3. The first “switch-over point” was connected with changes in the hydration shells of humic particles resulting in changes in their elasticity. The compressibility of water in the hydration shells is less than the compressibility of bulk water. The transfer of hydration water into bulk water increased the total compressibility of the solution, reducing the ultrasonic velocity. The aggregation of humic particles and the formation of rigid structures in systems with concentrations higher than 1 g·dm−3 was detected.

  17. Radiochromic film and polarization effects

    International Nuclear Information System (INIS)

    Yu, P.K.N.; Cheung, T.; Butson, M.J.; Cancer Services, Wollongong, NSW; Inwood, D.

    2004-01-01

    Full text: A new high sensitivity radiochromic film has been tested for its polarization properties. Gafchromic HS film has been shown to produce a relatively small (less than 3%) variation in measured optical density measured at 660nm wavelength when the light source is fully linear polarized and the film is rotated through 360 deg angle. Similar variations are seen when the detector is linearly polarized. If both light source and detector is linearly polarised variations in measured optical density can reach 15% when the film is rotated through 360 deg angle. This seems to be due to a phase shift in polarised light caused by the radiochromic film resulting in the polarised light source becoming out of phase with the polarised detector. Gafchromic HS radiochromic film produces a minimal polarization response with varying angle of rotation however we recommend that a polarization test be performed on a densitometry system to establish the extent of its polarization properties before accuracy dosimetry is performed with radiochromic HS film. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  18. Serum lipid and lipoprotein patterns of Iranian horses.

    Science.gov (United States)

    Asadi, F; Asadian, P; Shahriari, A; Pourkabir, M; Kazemi, A

    2011-12-01

    Patterns of serum biochemical parameters vary among horse breeds. The objective of the present study was to compare serum lipoproteins of Iranian Caspian ponies with those of other horses (Arabs and Thoroughbreds) in the Iranian region. Serum lipoprotein values were determined by agar-agarose gel electrophoresis and measured by scan densitometry. Moreover, serum triglyceride and cholesterol concentrations were determined and the results were analysed by one-way analysis of variance. Serum triglyceride and cholesterol values were 1.13 +/- 0.23 and 2.38 +/- 0.18 mmol/l in Caspian ponies, 1.96 +/- 0.49 and 1.92 +/- 0.25 mmol/l in Arab horses and 1.38 +/- 0.26 and 2.17 +/- 0.53 mmol/l in Thoroughbred horses. The relative percentages of alpha- (72.63 +/- 17.76%) and beta-lipoproteins (29.10 +/- 5.49%) in serum electrophoretic tracings from Caspian ponies were not significantly different from those of other horses (p > 0.05). The lipoprotein phenotype in Caspian ponies may be useful for evaluating metabolic diseases.

  19. Volume Adjustment of Lung Density by Computed Tomography Scans in Patients with Emphysema

    International Nuclear Information System (INIS)

    Shaker, S.B.; Dirksen, A.; Laursen, L.C.; Skovgaard, L.T.; Holstein-Rathlou, N.H.

    2004-01-01

    Purpose: To determine how to adjust lung density measurements for the volume of the lung calculated from computed tomography (CT) scans in patients with emphysema. Material and Methods: Fifty patients with emphysema underwent 3 CT scans at 2-week intervals. The scans were analyzed with a software package that detected the lung in contiguous images and subsequently generated a histogram of the pixel attenuation values. The total lung volume (TLV), lung weight, percentile density (PD), and relative area of emphysema (RA) were calculated from this histogram. RA and PD are commonly applied measures of pulmonary emphysema derived from CT scans. These parameters are markedly influenced by changes in the level of inspiration. The variability of lung density due to within-subject variation in TLV was explored by plotting TLV against PD and RA. Results: The coefficients for volume adjustment for PD were relatively stable over a wide range from the 10th to the 80th percentile, whereas for RA the coefficients showed large variability especially in the lower range, which is the most relevant for quantitation of pulmonary emphysema. Conclusion: Volume adjustment is mandatory in repeated CT densitometry and is more robust for PD than for RA. Therefore, PD seems more suitable for monitoring the progression of emphysema

  20. Separation and identification of DNA-carcinogen adduct conformers by polyacrylamide gel electrophoresis with laser-induced fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, G.A.; Jankowiak, R.; Farhat, J.H.; Small, G.J. (Ames Lab., IA (United States) Iowa State Univ., Ames (United States))

    1992-12-01

    The authors have developed a separation protocol utilizing high-resolution polyacrylamide gel electrophoresis (PAGE) to isolate stable anti-benzo[a]pyrene diol epoxide adducts of oligodeoxynucleotides. Both enantiomers produced multiple adduct species. The distribution of adduct types could be quantitated by densitometry of autoradiograms or Cerenkov counting of eluted oligomers modified by anti-BPDE isomers. Laser-induced fluorescence (LIF) spectra of eluted adducts at 4.2 K (fluorescence line-narrowing spectroscopy) and 77 K revealed that bands corresponded to pure conformers of pyrene chromophore. Carcinogen-modified oligodeoxynucleotides were single-stranded, but there were often considerable stacking interactions between the pyrenyl residues and the oligonucleotide bases, indicating that electrophoresed oligomers were single-stranded but in a native, versus random-coil conformation. The ability to identify and quantitate adducts by PAGE-LIF, coupled with the high resolution and sensitivity of both techniques, makes PAGE and LIF in tandem a potentially powerful tool in the study of chemical carcinogenesis or other ligand-DNA interactions. 43 refs., 7 figs., 1 tab.

  1. Neutron radiography applied to qualitative and quantitative non-destructive testing of metals and alloys

    International Nuclear Information System (INIS)

    Laporte, A.; Bayon, G.; Thierry, D.

    1981-01-01

    The radiation-material interaction between X-rays, gamma rays and neutrons is compared. The different possibilities of image detection are enumerated. The industrial testing installations associated with the Triton experimental reactor of the Fontenay-aux-Roses Nuclear Research Centre is described. A high performance testing unit is presented -the use of an intense flux of cold neutrons in a special building designed for neutrons radiographic testing- which will enter service in the second half of 1980, in association with the Orphee basic physics reactor of the Saclay Nuclear Research Centre. Concrete examples of manufacturing control on metal parts are given such as: testing of bonds between two metals of comparable density, testing of the homogeneity of high density alloys, testing of the homogeneity of low density alloys, testing of materials with high neutron contrast. Neutron radiographic testing not only achieves qualitative but also quantitative analysis of the films, on two levels, dimensional measurement and homogeneity and/or concentration measurement, by densitometry. Testing methods used for complete quantitative analysis of boronated aluminium plates used in the nuclear industry are examined. Perspectives concerning routine tests, by dealing with fundamental aspects of standardization and the knowledge of the phenomena involved in this testing technique are given [fr

  2. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  3. Hyperdense dots mimicking microcalcifications : Mammographic findings

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Park, Jeong Mi; Goo, Hyun Woo; Bang, Sun Woo

    1996-01-01

    To differentiate fine hyperdense dots mimicking microcalcifications from true microcalcifications on mammography. Mammograms showing hyperdense dots in ten patients (mean age, 59 years) were evaluated. Two radiologists were asked to differentiate with the naked eye the hyperdense dots seen on ten mammograms and proven microcalcifications seen on ten mammograms. Densitometry was also performed for all lesions and the contrast index was calculated. The shape and distribution of the hyperdense dots were evaluated and enquires were made regarding any history of breast disease and corresponding treatment. Biopsies were performed for two patients with hyperdense dots. Two radiologists made correct diagnoses in 19/20 cases(95%). The contrast index was 0.10-0.88 (mean 0.58) for hyperdense dots and 0.02-0.45 (mean 0.17) for true microcalcifications. The hyperdense dots were finer and homogeneously rounder than the microcalcifications. Distribution of the hyperdense dots was more superficial in subcutaneous fat (seven cases) and subareolar area (six cases). All ten patients with hyperdense dots had history of mastitis and abscesses and had been treated by open drainage (six cases) and/or folk remedy (four cases). In eight patients, herb patches had been attached. Biopsies of hyperdense dots did not show any microcalcification or evidence of malignancy. These hyperdense dots were seen mainly in older patients. Their characteristic density, shape, distribution and clinical history makes differential diagnosis from true microcalcifications easy and could reduce unnecessary diagnostic procedures such as surgical biopsy

  4. Studies of osteoporosis within the Debrecen Regional Osteoporosis Program (DROP) in Hungary using isotope related techniques. Progress report and plans for the completion

    International Nuclear Information System (INIS)

    Balogh, A.

    2000-01-01

    The aim of the research carried out within the above CRP was during a four-year period devoted to measuring bone density in the lumbar spine and the femoral neck in 15-50 year old normal subjects of both sexes, and studying the bone composition of selected bone biopsy and autopsy specimens. These activities were planned in conformity with the guidelines issued for this coordinated research programme. Mean DXA bone densitometry results appear to be slightly lower than a typical European standard e.g. used by Lunar as population reference database originating from Germany, however it is unlikely that the difference will be statistically significant. Further number of measurements will make it possible to establish our own regional database for comparison. This would be especially use for the population status below 20 years of age. Additionally, the Questionnaires fulfil similar task giving a chance to take regional Hungarian data on the variables included in the questionnaires. At the time of this report there is a depth of our centre concerning some components of the research plan. It seems however realistic to catching up by the end of the 5 year research plan with the most important components of the original proposal. Some of the imbalance of the detailed work can be rectified only during the planned extra year beyond the completion of the 4 calendar year calculated from the start-up date of 1 December 1994. This is proposed according to the original study plan

  5. Errors in dual-energy X-ray scanning of the hip because of nonuniform fat distribution.

    Science.gov (United States)

    Tothill, Peter; Weir, Nicholas; Loveland, John

    2014-01-01

    The variable proportion of fat in overlying soft tissue is a potential source of error in dual-energy X-ray absorptiometry (DXA) measurements of bone mineral. The effect on spine scanning has previously been assessed from cadaver studies and from computed tomography (CT) scans of soft tissue distribution. We have now applied the latter technique to DXA hip scanning. The CT scans performed for clinical purposes were used to derive mean adipose tissue thicknesses over bone and background areas for total hip and femoral neck. The former was always lower. More importantly, the fat thickness differences varied among subjects. Errors because of bone marrow fat were deduced from CT measurements of marrow thickness and assumed fat proportions of marrow. The effect of these differences on measured bone mineral density was deduced from phantom measurements of the bone equivalence of fat. Uncertainties of around 0.06g/cm(2) are similar to those previously reported for spine scanning and the results from cadaver measurements. They should be considered in assessing the diagnostic accuracy of DXA scanning. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  6. Autoradiographic localization of GABA-regulated chloride ionophore binding site using t-[3H]butylbicycloorthobenzoate (TBOB)

    International Nuclear Information System (INIS)

    O'Connor, L.H.; McEwen, B.S.

    1986-01-01

    t-Butylbicycloorthobenzoate (TBOB) has been shown to bind with high affinity to sites on or near the chloride ionophore in rat brain membrane preparations. The present study used in vitro quantitative autoradiography to localize the regional distribution of [ 3 H]TBOB binding sites in rat forebrain. Receptors were labelled with 10 nM [ 3 H]TBOB. Nonspecific binding was determined by adding 10 μM picrotoxin to the incubation. Autoradiograms were generated using LKB Ultrofilm and then quantitated using computer-assisted spot-densitometry. The highest specific binding was found in frontal cortex layer 4, islands of Calleja, and ventral palladium. High binding was also found in many regions including anterior hypothalamic n., ventromedial hypothalamic n., dentate gyrus, stratum oriens and stratum lacunosum moleculare of hippocampus, and substantia nigra. Nonspecific binding represented 5 to 15% of total binding and was uniformly low throughout all brain regions. Thus, this selective probe for GABA-regulated chloride ionophore binding sites should provide a useful tool for characterizing this system and its relationship to convulsant and depressant drug action

  7. BODY COMPOSITION AND BONE MINERAL DENSITY IN WOMEN WITH RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    S. E. Myasoedova

    2016-01-01

    Full Text Available Objective: to establish specific features of body composition, skeletal muscle changes and bone mineral density (BMD in middle-aged and elderly female patients with rheumatoid arthritis (RA as compared to female subjects without RA.Materials and methods. The study included 86 female patients with RA aged 59.06 ± 7.52 years and 81 female subjects without RA aged 57.4 ± 5.3 years. Body composition and BMD in spine and femur was assessed using Lunar Prodidgy device (General Electric. Sarcopenia was defined as lean mass index (LMI of < 5.64 kg/m2 .Results. We have detected statistically significant decrease in fat, muscle and femoral BMD in female patients with RA as compared to their non-RA counterparts. Sarcopenia in the form of osteopenic sarcopenia and osteosarcopenia obesity was detected in 13.95 % RA patients vs 4.94 % non-RA subjects based on LMI findings. Both groups had high prevalence of osteopenia obesity.Conclusions. Assessment of the body composition by radiographic densitometry in female RA patients with osteopenia or osteoporosis may be used to detect sarcopenia and its phenotypes in order to inform prognosis and adjust the management plan.

  8. Electrophoretic mobility patterns of collagen following laser welding

    Science.gov (United States)

    Bass, Lawrence S.; Moazami, Nader; Pocsidio, Joanne O.; Oz, Mehmet C.; LoGerfo, Paul; Treat, Michael R.

    1991-06-01

    Clinical application of laser vascular anastomosis in inhibited by a lack of understanding of its mechanism. Whether tissue fusion results from covalent or non-covalent bonding of collagen and other structural proteins is unknown. We compared electrophoretic mobility of collagen in laser treated and untreated specimens of rat tail tendon (>90% type I collagen) and rabbit aorta. Welding was performed, using tissue shrinkage as the clinical endpoint, using the 808 nm diode laser (power density 14 watts/cm2) and topical indocyanine green dye (max absorption 805 nm). Collagen was extracted with 8 M urea (denaturing), 0.5 M acetic acid (non-denaturing) and acetic acid/pepsin (cleaves non- helical protein). Mobility patterns on gel electrophoresis (SDS-PAGE) after urea or acetic acid extraction were identical in the lasered and control tendon and vessel (confirmed by optical densitometry), revealing no evidence of formation of novel covalent bonds. Alpha and beta band intensity was diminished in pepsin incubated lasered specimens compared with controls (optical density ratio 0.00 +/- 9 tendon, 0.65 +/- 0.12 aorta), indicating the presence of denatured collagen. With the laser parameters used, collagen is denatured without formation of covalent bonds, suggesting that non-covalent interaction between denatured collagen molecules may be responsible for the weld. Based on this mechanism, welding parameters can be chosen which produce collagen denaturation without cell death.

  9. Radiograma de tórax e tomografia computadorizada na avaliação do enfisema pulmonar Chest X-ray and computed tomography in the evaluation of pulmonary emphysema

    Directory of Open Access Journals (Sweden)

    Klaus Loureiro Irion

    2007-12-01

    Full Text Available O enfisema é uma condição do pulmão, caracterizada pelo aumento acima do normal no tamanho dos espaços aéreos distais ao bronquíolo terminal. Atualmente, o enfisema é a quarta causa de morte nos EUA, afetando 14 milhões de pessoas. O presente artigo descreve as principais ferramentas no diagnóstico por imagem do enfisema, desde o início até os dias de hoje. Relata as técnicas tradicionais, como radiograma de tórax, e as evoluções no campo da tomografia computadorizada (TC, como a TC de alta resolução e a densitovolumetria pulmonar por TC tridimensional.Emphysema is a condition of the lung, characterized by the abnormal increase in the size of the airspace distal to the terminal bronchioles. Currently, emphysema is the fourth leading cause of death in the USA, affecting 14 million people. The present article describes the principal tools in the imaging diagnosis of emphysema, from the early days until the present. We describe traditional techniques, such as chest X-ray, together with the evolution of computed tomography (CT to more advanced forms, such as high resolution CT, as well as three-dimensional CT densitometry and volumetric assessment.

  10. Factors responsible for formation of severity of inflammatory parodontal diseases in adolescent girls with menstrual dysfunction

    Directory of Open Access Journals (Sweden)

    Ye. A. Kliuchka

    2017-06-01

    Full Text Available Determining the factors of formation of severity of parodontal inflammatory diseases (PID in adolescent girls with menstrual dysfunction (MD makes it possible to determine the predictors of severity of PID and, on this basis, to develop differentiated methods for their prevention. The aim. To determine the factors responsible for formation of PID severity in adolescent girls with MD. The materials and methods. The following data were studied in adolescent girls with MD with varying severity of PID: obstetric and genealogical anamnesis, lifestyles of adolescents, indices of oral hygiene, dental status, densitometry, content of CA ++ and sIgA in saliva, lysozyme and urease activity in saliva, cytobiophysical potential of buccal epithelium nuclei. The findings. In patients with more severe course of PID, in comparison to milder course of PID, there was determined a more significant degree of weakened heredity in relation to chronic dental and somatic pathology, unfavorable course of pregnancy and childbirth, violations of a healthy lifestyle and oral hygiene in adolescents, anomalies in the development of dentoalveolar system, dysbiosis of oral cavity, reduced local and systemic immunoresistance. Conclusion: The determined predictors of the severity of PID in adolescent girls with MD make it possible to develop differentiated methods for their prevention.

  11. Pediatric dual-energy X-ray absorptiometry: interpretation and clinical and research application

    Directory of Open Access Journals (Sweden)

    Jung Sub Lim

    2010-03-01

    Full Text Available Peak bone mass is established predominately during childhood and adolescence. It is an important determinant of future resistance to osteoporosis and fractures to gain bone mass during growth. The issue of low bone density in children and adolescents has recently attracted much attention and the use of pediatric dual-energy X-ray absorptiometry (DXA is increasing. The process of interpretation of pediatric DXA results is different from that of adults because normal bone mineral density (BMD of children varies by age, body size, pubertal stage, skeletal maturation, sex, and ethnicity. Thus, an appropriate normal BMD Z-score reference value with Z-score should be used to detect and manage low BMD. Z-scores below -2.0 are generally considered a low BMD to pediatrician even though diagnoses of osteoporosis in children and adolescents are usually only made in the presence of at least one fragility fracture. This article will review the basic knowledge and practical guidelines on pediatric DXA based on the International Society for Clinical Densitometry (ISCD Pediatric Official Positions. Also discussed are the characteristics of normal Korean children and adolescents with respect to BMD development. The objective of this review is to help pediatricians to understand when DXA will be useful and how to interpret pediatric DXA reports in the clinical practice for management of children with the potential to develop osteoporosis in adulthood.

  12. Total lymphoid irradiation in the Wistar rat: technique and dosimetry

    International Nuclear Information System (INIS)

    Hoogenhout, J.; Kazem, I.; de Jong, J.

    1983-01-01

    The technical and dosimetric aspects of total lymphoid irradiation (TLI) in the Wistar rat were evaluated as part of a set-up to develop a new model for tumor xenotransplantation. Information obtained from anatomical dissections, radionuclide imaging of the spleen, lymphography and chromolymphography was used to standardize the localization portals cut out in a lead plate. The two portals encompassed the lymphoid tissue above and below the diaphragm. A specially designed masonite phantom was used to measure the dose distribution in the simulated target volumes. Ionization chamber dosimetery, thermoluminescence dosimetry and film densitometry were used for measuring exposure and absorbed dose. Irradiation was performed with 250 kV X rays (HVL 3.1 mm Cu). The dose rate was regulated by adjusting the treatment distance. The dose inhomogeneity measured in the target volumes varied between 80-100%. The side scatter dose to non target tissues under the shielded area between the two portals ranged between 20-30%. The technique and dosimetry of total lymphoid irradiation in Wistar rats are now standardized and validated and pave the way for tumor xenotransplantation experiments

  13. Characterization of the Ljubljana TRIGA thermal column neutron radiographic facility

    International Nuclear Information System (INIS)

    Nemec, T.; Rant, J.; Kristof, E.; Glumac, B.

    1995-01-01

    An extensive characterization of the neutron beam of the existing neutron radiographic facility in the thermal column of the Ljubljana Triga Mark II research reactor is in progress. Neutron beam characteristics are needed to determine the effect of various neutron and gamma radiation on the neutron radiographic image. Commercially available medical scintillator converter screens based on Gd dioxy sulphite as well as Gd metal neutron converters are used to record neutron radiographic image. Thermal, epithermal and fast neutron fluxes were measured using Au and In activation detectors and cadmium ratio is determined. Neutron beam flux profiles are measured by film densitometry and by Au activation detector wires. By exposing films shielded by boral or lead plates individual contributions of thermal, epithermal neutrons and gamma radiation are estimated by densitometric measurements. By recording images of neutron image quality indicators BPI (Beam Purity Indicator) and SI (Sensitivity Indicator) produced by Riso, standard neutron radiography image characteristic are established. In gamma dosimetric measurements thermoluminescent detectors (CaF 2 Mn) are used. (author)

  14. Ocular forward light scattering and corneal backward light scattering in patients with dry eye.

    Science.gov (United States)

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Asonuma, Sanae; Mitamura, Hayato; Oie, Yoshinori; Soma, Takeshi; Tsujikawa, Motokazu; Kawasaki, Satoshi; Nishida, Kohji

    2014-09-18

    To evaluate ocular forward light scattering and corneal backward light scattering in patients with dry eye. Thirty-five eyes in 35 patients with dry eye and 20 eyes of 20 healthy control subjects were enrolled. The 35 dry eyes were classified into two groups according to whether superficial punctate keratopathy in the central 6-mm corneal zone (cSPK) was present or not. Ocular forward light scattering was quantified with a straylight meter. Corneal backward light scattering from the anterior, middle, and posterior corneal parts was assessed with a corneal densitometry program using the Scheimpflug imaging system. Both dry eye groups had significantly higher intraocular forward light scattering than the control group (both Pdry eye group with cSPK had significantly higher values in anterior and total corneal backward light scattering than the other two groups. Moderate positive correlations were observed between the cSPK score and corneal backward light scattering from the anterior cornea (R=0.60, Pdry eyes than in normal eyes. Increased corneal backward light scattering in dry eye at least partially results from cSPK overlying the optical zone. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  15. Heterologous expression of Homo sapiens alpha-folate receptors in E. coli by fusion with a trigger factor for enhanced solubilization.

    Science.gov (United States)

    Miranda, Beatriz Nogueira Messias; Fotoran, Wesley Luzetti; Canduri, Fernanda; Souza, Dulce Helena Ferreira; Wunderlich, Gerhard; Carrilho, Emanuel

    2018-02-01

    The role of Alpha folate receptors (FRα) in folate metabolism and cancer development has been extensively studied. The reason for this is not only associated to its direct relation to disease development but also to its potential use as a highly sensitive and specific biomarker for cancers therapies. Over the recent years, the crystal structures of human FRα complexed with different ligands were described relying on an expensive and time-consuming production process. Here, we constructed an efficient system for the expression and purification of a human FRα in E. coli. Unlike a conventional expression method we used a specific protein fusion expressing the target protein together with a trigger factor (TF). This factor is a chaperone from E. coli that assists the correct folding of newly synthesized polypeptide chains. The activity of rTFFRα was comparable to glycosylphosphatidylinositol (GPI) anchored proteins extracted from HeLa tumor cells. Our work demonstrates a straightforward and versatile approach for the production of active human FRα by heterologous expression; this approach further enhances the development of inhibition studies and biotechnological applications. The purified product was then conjugated to liposomes, obtaining a 35% higher signal from densitometry measurement on the immunoblotting assay in the contruct containing the Ni-NTA tag, as a mimesis of an exosome, which is of vital importance to nanotherapeutic techniques associated to treatment and diagnosis of tumors. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Effect of a carbonated HAP/β-glucan composite bone substitute on healing of drilled bone voids in the proximal tibial metaphysis of rabbits

    International Nuclear Information System (INIS)

    Borkowski, Leszek; Pawłowska, Marta; Radzki, Radosław P.; Bieńko, Marek; Polkowska, Izabela; Belcarz, Anna; Karpiński, Mirosław; Słowik, Tymoteusz; Matuszewski, Łukasz; Ślósarczyk, Anna; Ginalska, Grażyna

    2015-01-01

    A novel elastic hydroxyapatite-based composite of high surgical handiness has been developed. Its potential application in orthopedics as a filler of bone defects has been studied. The biomaterial was composed of carbonated hydroxyapatite (CHAP) granules and polysaccharide polymer (β-1,3-glucan). Cylinders of 4 mm in diameter and 6 mm in length were implanted into bone cavities created in the proximal metaphysis of tibiae of 24 New Zealand white rabbits. 18 sham-operated animals were used as controls. After 1, 3 or 6 months, the rabbits were euthanized, the bones were harvested and subjected to analysis. Radiological images and histological sections revealed integration of implants with bone tissue with no signs of graft rejection. Peripheral quantitative computed tomography (pQCT) indicated the stimulating effect of the biomaterial on bone formation and mineralization. Densitometry (DXA) analysis suggested that biomineralization of bones was preceded by bioresorption and gradual disappearance of porous ceramic granules. The findings suggest that the CHAP–glucan composite material enables regeneration of bone tissue and could serve as a bone defect filler. - Highlights: • Highly porous carbonate HAP granules and β-1,3-glucan were used to fill bone voids. • Critical size defects of rabbit tibiae were filled with the composite scaffolds. • Biocompatibility, mineralization and osseointegration of implants were examined. • Histological analysis indicated a high biocompatibility of composite grafts. • We report penetration of bony tissue into implants and advanced osseointegration

  17. Cohort Profile: The JS High School study (JSHS): a cohort study of Korean adolescents.

    Science.gov (United States)

    Choi, Dong Phil; Lee, Joo Young; Kim, Hyeon Chang

    2017-04-01

    Major aetiologies of atherosclerotic cardiovascular diseases begin in childhood and atherosclerotic vascular abnormalities can be observed among children and adolescents. Adolescent cohort studies have important advantages because they can observe earlier changes in vascular structure and function. The purpose of the JS High School study (JSHS) is to identify biomarkers predicting or indicating early structural and functional vascular change in adolescents. The JSHS is a prospective cohort study of a Korean adolescent population. The target population of the JSHS was first-graders (aged 14 to17 years) at a high school of South Korea. Enrolment and baseline examinations were conducted in years 2007, 2010, 2011 and 2012. Among the total eligible population of 1115 students, 1071 (96.1%) participated in the study and completed all baseline examinations. Informed consent forms were obtained from each participant and his/her parent or guardian. Baseline examinations include: questionnaires on demographics, health behaviours, medical history, and depression symptoms; fasting blood analysis; anthropometric measurement; body impedance analysis; blood pressure measurement; radial artery tonometry; bone densitometry; pulmonary function tests; and carotid ultrasonography. Participants enrolled from 2007 through 2012 were re-examined after 30 months of follow-up, and those who enrolled in 2012 were re-examined after 24 months of follow-up. The corresponding author may be contacted for potential collaboration and data access. © The Author 2015; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  18. Functional Effects of Prebiotic Fructans in Colon Cancer and Calcium Metabolism in Animal Models.

    Science.gov (United States)

    Rivera-Huerta, Marisol; Lizárraga-Grimes, Vania Lorena; Castro-Torres, Ibrahim Guillermo; Tinoco-Méndez, Mabel; Macías-Rosales, Lucía; Sánchez-Bartéz, Francisco; Tapia-Pérez, Graciela Guadalupe; Romero-Romero, Laura; Gracia-Mora, María Isabel

    2017-01-01

    Inulin-type fructans are polymers of fructose molecules and are known for their capacity to enhance absorption of calcium and magnesium, to modulate gut microbiota and energy metabolism, and to improve glycemia. We evaluated and compared the effects of Chicory inulin "Synergy 1®" and inulin from Mexican agave "Metlin®" in two experimental models of colon cancer and bone calcium metabolism in mice and rats. Inulins inhibited the development of dextran sulfate sodium-induced colitis and colon cancer in mice; these fructans reduced the concentration of tumor necrosis factor alpha and prevented the formation of intestinal polyps, villous atrophy, and lymphoid hyperplasia. On the other hand, inulin treatments significantly increased bone densitometry (femur and vertebra) in ovariectomized rats without altering the concentration of many serum biochemical parameters and urinary parameters. Histopathology results were compared between different experimental groups. There were no apparent histological changes in rats treated with inulins and a mixture of inulins-isoflavones. Our results showed that inulin-type fructans have health-promoting properties related to enhanced calcium absorption, potential anticancer properties, and anti-inflammatory effects. The use of inulin as a prebiotic can improve health and prevent development of chronic diseases such as cancer and osteoporosis.

  19. Functional Effects of Prebiotic Fructans in Colon Cancer and Calcium Metabolism in Animal Models

    Directory of Open Access Journals (Sweden)

    Marisol Rivera-Huerta

    2017-01-01

    Full Text Available Inulin-type fructans are polymers of fructose molecules and are known for their capacity to enhance absorption of calcium and magnesium, to modulate gut microbiota and energy metabolism, and to improve glycemia. We evaluated and compared the effects of Chicory inulin “Synergy 1®” and inulin from Mexican agave “Metlin®” in two experimental models of colon cancer and bone calcium metabolism in mice and rats. Inulins inhibited the development of dextran sulfate sodium-induced colitis and colon cancer in mice; these fructans reduced the concentration of tumor necrosis factor alpha and prevented the formation of intestinal polyps, villous atrophy, and lymphoid hyperplasia. On the other hand, inulin treatments significantly increased bone densitometry (femur and vertebra in ovariectomized rats without altering the concentration of many serum biochemical parameters and urinary parameters. Histopathology results were compared between different experimental groups. There were no apparent histological changes in rats treated with inulins and a mixture of inulins-isoflavones. Our results showed that inulin-type fructans have health-promoting properties related to enhanced calcium absorption, potential anticancer properties, and anti-inflammatory effects. The use of inulin as a prebiotic can improve health and prevent development of chronic diseases such as cancer and osteoporosis.

  20. Effect of Clothing on Measurement of Bone Mineral Density.

    Science.gov (United States)

    McNamara, Elizabeth A; Feldman, Anna Z; Malabanan, Alan O; Abate, Ejigayehu G; Whittaker, LaTarsha G; Yano-Litwin, Amanda; Dorazio, Jolene; Rosen, Harold N

    2016-01-01

    It is unknown whether allowing patients to have BMD (bone mineral density) studies acquired while wearing radiolucent clothing adlib contributes appreciably to the measurement error seen. To examine this question, a spine phantom was scanned 30 times without any clothing, while draped with a gown, and while draped with heavy winter clothing. The effect on mean BMD and on SD (standard deviation) was assessed. The effect of clothing on mean or SD of the area was not significant. The effect of clothing on mean and SD for BMD was small but significant and was around 1.6% for the mean. However, the effect on BMD precision was much more clinically important. Without clothing the spine phantom had an least significant change of 0.0077 gm/cm(2), while when introducing variability of clothing the least significant change rose as high as 0.0305 gm/cm(2). We conclude that, adding clothing to the spine phantom had a small but statistically significant effect on the mean BMD and on variance of the measurement. It is unlikely that the effect on mean BMD has any clinical significance, but the effect on the reproducibility (precision) of the result is likely clinically significant. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  1. Effect of smoking cessation on quantitative computed tomography in smokers at risk in a lung cancer screening population

    Energy Technology Data Exchange (ETDEWEB)

    Jobst, Bertram J.; Eichinger, Monika; Wielpuetz, Mark O. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Centre Heidelberg (TLRC), Member of the German Lung Research Centre (DZL), Heidelberg (Germany); Thoraxklinik at the University of Heidelberg, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Weinheimer, Oliver; Trauth, Mila; Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Centre Heidelberg (TLRC), Member of the German Lung Research Centre (DZL), Heidelberg (Germany); Thoraxklinik at the University of Heidelberg, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Becker, Nikolaus; Motsch, Erna; Gross, Marie-Luise; Eigentopf, Anke [German Cancer Research Centre (DKFZ Heidelberg), Division of Cancer Epidemiology, Heidelberg (Germany); Tremper, Jan; Delorme, Stefan [German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany)

    2018-02-15

    To longitudinally evaluate effects of smoking cessation on quantitative CT in a lung cancer screening cohort of heavy smokers over 4 years. After 4 years, low-dose chest CT was available for 314 long-term ex-smokers (ES), 404 continuous smokers (CS) and 39 recent quitters (RQ) who quitted smoking within 2 years after baseline CT. CT acquired at baseline and after 3 and 4 years was subjected to well-evaluated densitometry software, computing mean lung density (MLD) and 15th percentile of the lung density histogram (15TH). At baseline, active smokers showed significantly higher MLD and 15TH (-822±35 and -936±25 HU, respectively) compared to ES (-831±31 and -947±22 HU, p<0.01-0.001). After 3 years, CS again had significantly higher MLD and 15TH (-801±29 and -896±23 HU) than ES (-808±27 and -906±20 HU, p<0.01-0.001) but also RQ (-813±20 and -909±15 HU, p<0.05-0.001). Quantitative CT parameters did not change significantly after 4 years. Importantly, smoking status independently predicted MLD at baseline and year 3 (p<0.001) in multivariate analysis. On quantitative CT, lung density is higher in active smokers than ex-smokers, and sustainably decreases after smoking cessation, reflecting smoking-induced inflammation. Interpretations of quantitative CT data within clinical trials should consider smoking status. (orig.)

  2. Studies of osteoporosis in Singapore using isotope related technique. Progress report: June 1997 - June 1998

    International Nuclear Information System (INIS)

    Bose, K.

    2000-01-01

    Osteoporosis is one of the common medical problems facing an aging population. It is projected that the number of hip fractures occurring worldwide will increase from 1.66 million in 1990 to 6.26 million by the year 2050. Many studies have shown a strong relationship between low bone density and increased fracture risk. The World Health Organization (WHO) has proposed a threshold of bone mineral density (BMD) based on peak bone mass, with osteoporosis denoting a value of BMD that is 2.5 standard deviations or more below the peak bone mass. The interpretation of bone mineral densitometry results for a particular individual relies on valid reference data from a representative population sample. Recent studies have suggested that apart from bone density, there are racial differences in hip axis length. A longer hip axis length is associated with an increased risk of fracture. The hip axis length of Asian and black women were reported to be significantly shorter than white women. Japanese women were found to have a shorter hip axis length and a lower hip fracture incidence than American women despite lower bone density values. The main objectives of this study was to a) determine the age of peak bone density in each study group, b) quantify differences in bone density as functions of age and sex. The hip axis length was also measured

  3. Evaluation of dose distributions in gamma chamber using glass plate detector

    Directory of Open Access Journals (Sweden)

    Narayan Pradeep

    2008-01-01

    Full Text Available A commercial glass plate of thickness 1.75 mm has been utilized for evaluation of dose distributions inside the irradiation volume of gamma chamber using optical densitometry technique. The glass plate showed linear response in the dose range 0.10 Kilo Gray (kGy to 10 kGy of cobalt-60 gamma radiation with optical sensitivity 0.04 Optical Density (OD /kGy. The change in the optical density at each identified spatial dose matrix on the glass plate in relation to the position in the irradiation volume has been presented as dose distributions inside the gamma chamber. The optical density changes have been graphically plotted in the form of surface diagram of color washes for different percentage dose rate levels as isodose distributions in gamma chamber. The variation in dose distribution inside the gamma chamber unit, GC 900, BRIT India make, using this technique has been observed within ± 15%. This technique can be used for routine quality assurances and dose distribution validation of any gamma chamber during commissioning and source replacement. The application of commercial glass plate for dose mapping in gamma chambers has been found very promising due to its wider dose linearity, quick measurement, and lesser expertise requirement in application of the technique.

  4. Cartilage Degeneration, Subchondral Mineral and Meniscal Mineral Densities in Hartley and Strain 13 Guinea Pigs

    Science.gov (United States)

    Sun, Yubo; Scannell, Brian P; Honeycutt, Patrick R; Mauerhan, David R; H, James Norton; Hanley Jr, Edward N

    2015-01-01

    Osteoarthritis is a joint disease involved in articular cartilage, subchondral bone, meniscus and synovial membrane. This study sought to examine cartilage degeneration, subchondral bone mineral density (BMD) and meniscal mineral density (MD) in male Hartley, female Hartley and female strain 13 guinea pigs to determine the association of cartilage degeneration with subchondral BMD and meniscal MD. Cartilage degeneration, subchondral BMD and meniscal MD in 12 months old guinea pigs were examined with histochemistry, X-ray densitometry and calcium analysis. We found that male Hartley guinea pigs had more severe cartilage degeneration, subchondral BMD and meniscal MD than female Hartley guinea pigs, but not female strain 13 guinea pigs. Female strain 13 guinea pigs had more severe cartilage degeneration and higher subchondral BMD, but not meniscal MD, than female Hartley guinea pigs. These findings indicate that higher subchondral BMD, not meniscal MD, is associated with more severe cartilage degeneration in the guinea pigs and suggest that abnormal subchondral BMD may be a therapeutic target for OA treatment. These findings also indicate that the pathogenesis of OA in the male guinea pigs and female guinea pigs are different. Female strain 13 guinea pig may be used to study female gender-specific pathogenesis of OA. PMID:26401159

  5. Regional osteoporosis in western Sydney women

    International Nuclear Information System (INIS)

    Larcos, G.; Lawson-Smith, R.

    1998-01-01

    Full text: Recently, 15% of elderly Japanese-American women have been shown to have marked heterogeneity of bone mineral density (BMD) between measured sites. The purposes of this study were to determine (1 ) the prevalence of this finding in an Australian population; and (2) potential association with clinical factors such as age, years since menopause (YSM), alcohol, smoking, family history, exercise, and body mass index. One hundred and fourteen peri-or post- menopausal Caucasian women (mean age 55 + 8.8 years) were referred for osteoporotic (OP) fracture risk assessment. Patients (pts) had no disorders or drugs known to affect BMD and no evidence of scoliosis or arthritic change. Bone densitometry of the lumbar spine (PA), hip and distal radius were measured using a Norland XR-26. According to WHO criteria, 30 pts (26%) were normal (T score > -1) at all sites; no pts (0%) had generalised OP (T score < -2.5); 29 (25%) had OP in one or two sites only (hip = 25, spine = 13, wrist = 1); the remaining 55 pts (48%) were osteogenic (-2.5 < T score < -1) in at least one site. Using multivariate logistic regression analysis, only YSM predicted regional OP (odds ratio = 1.14; p< O.001) Thus, clinically important heterogeneity of BMD occurs in about 25% of Western Sydney women; of clinical factors only YSM is independently associated with regional OP. Fracture risk classification may be improved by BMD measurement of multiple sites

  6. Evaluation of regional pulmonary ventilation by videodensitometry using a new X-ray image processor

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Kanai, Hisakata; Handa, Kenjiro; Takizawa, Masaomi

    1988-01-01

    A new video image processing device has been produced in order to assess regional pulmonary ventilation. This device consists of a microcomputer, digital frame memory, digitizer, videomonitor, joystick and videotape recorder. The changing radiographic density of the lungs during deep respiration and forced expiration is recorded by the videotape recorder, which is connected to an image intensifier television system. This device allows the examining physician to place 6 rectangular windows of variable size over any portion of the video image using the joystick, and to measure the brightness level within these windows simultaneously. It is very characteristic that the video-densitometric curve and marks of the windows are superimposed on the frozen final frame of the sampled images. By this procedure, fair videodensigrams were obtained in various respiratory diseases, and reduction of ventilatory amplitude was shown in the hypoventilatory regions. The joint use of video-densitometry and perfusion lung scintigraphy provided helpful information concerning the regional ventilation/perfusion relationship. The videodensitometry of the lung the new X-ray image processor offers routine screening evaluation of regional pulmonary ventilation abnormalities over the entire video image of the lungs without more effort required of the patients. (author)

  7. Diagnostic relevance of a questionnaire for osteoporosis risk assessment - comparison with osteodensitometry data

    International Nuclear Information System (INIS)

    Boyanov, M.

    2001-01-01

    The early detection of osteoporosis is a key factor for reducing associated costs. Clinical risk factors have been used for selection of subjects suitable for bone densitometry. Questionnaires for preliminary osteoporosis risk assessment have already been implemented. The purpose of this study is to apply an original questionnaire for risk assessment and to assess its diagnostic value by comparison to forearm bone mineral density data (BMD). 285 females were included - mean age 53.5 ±8.8 years, 82% were menopausal. The osteoporosis risk was assessed by an original score system based on a questionnaire. Forearm BMD was measured by single-energy x-ray absorptiometry using own reference ranges. Two diagnosis models were tested by 'cluster analysis' - classifications with 3 or 2 diagnostic items. The second proved better. Sensitivity in detecting women with forearm osteoporosis was 86.7%, specificity - 16.5% and 75.8% of all women were correctly classified. The total score distribution in the study population is skewed to the right which reflects the two subgroups - at high and low risk for osteoporosis. The value of a similar questionnaire in the overall strategy for diagnosis and treatment of low BMD is discussed. (author)

  8. CT scans in studies of the dynamics of liposynthesis and lipolysis of the human liver

    International Nuclear Information System (INIS)

    Huebener, K.H.; Schmitt, W.G.H.

    1981-01-01

    Following an analysis of the most important metabolic disturbances and other diseases associated ith fatty degeneration of the liver, it is shown, basing on a previous study, by means of examples, that subtle diagnosis of changes of the fatty content of the liver can be achieved via CT density measurement. Lipolysis in alcoholic fatty liver is quantified during abstention from alcohol, and a lipolysis factor of 1% fatty decomposition per day is determined from the measurements. Observations in pancreatitis with liver lipid storage during the course of the disease, point to an enzymatic weakness in lipid metabolism. Case histories show fatty degeneration associated with an enhanced cortisone serum level (in adrenal adenoma and cortisone therapy) and in poorly stabilized diabetes mellitus. It is concluded from the studies that determination of the relative fatty content by CT densitometry should be conducted as a routine procedure and that pathological lipid content should stimulate subtle diagnosis of the pancreas and the adrenals. In addition, examinations repeated during the course of the disease with assessment of changes in fatty content, will be useful for assessing the value of the therapy employed. (orig.) [de

  9. Increased levels of metallothionein in placenta of smokers

    International Nuclear Information System (INIS)

    Ronco, Ana Maria; Arguello, Graciela; Suazo, Myriam; Llanos, Miguel N.

    2005-01-01

    Experiments were designed to evaluate and compare metallothionein (MT), zinc and cadmium levels in human placentas of smoking and non-smoking women. Smoking was assessed by self-reported cigarette consumption and urine cotinine levels before delivery. Smoking pregnant women with urine cotinine levels higher than 130 ng/ml were included in the smoking group. Determination of placental MT was performed by western blot analysis after tissue homogenization and saturation with cadmium chloride (1000 ppm). Metallothionein was analyzed with a monoclonal antibody raised against MT-1 and MT-2 and with a second anti mouse antibody conjugated to alkaline phosphatase. Zinc and cadmium were determined by neutron activation analysis and atomic absorption spectrometry respectively. Smokers showed higher placental MT and cadmium levels, together with decreased newborn birth weights, as compared to non-smokers. The semi-quantitative analysis of western blots by band densitometry indicated that darker bands corresponded to MT present in smokers' samples. This study confirms that cigarette smoking increases cadmium accumulation in placental tissue and suggests that this element has a stimulatory effect on placental MT production

  10. Differences in bone mineral density between mildly and definitively osteoporotic women

    International Nuclear Information System (INIS)

    Heuck, A.F.; Steiger, P.; Block, J.E.; Glueer, C.C.; Steiger, S.; Genant, H.K.

    1988-01-01

    The authors studied 68 postmenopausal women to determine the ability of three bone densitometry techniques (QCT and DPA of the spine and SPA of the radius) for discriminating patients with mild wedge deformities (20%-25% wedge) from definitive compression fractures (≥25% wedge or crush fracture). Decrements of bone density between mildly osteoporotic women and osteoporotic women were -20% (P<.001) for QCT, -11% (P<.01) for DPA, and -5.5% (not significant) for SPA. Z-scores were -0.7 (P<.001) for QCT, -0.6 (P<.01) for DPA, and -0.4 (not significant) for SPA. The group was divided into quartiles of bone density with odds ratios calculated and the highest quartile acting as the reference group (risk=1). Odds ratios for the lower quartiles were 2.3, 5.3, and 10.7 for QCT; 0.4, 2.9, and 3.7 for DPA; and 0.7, 0.7, and 2.7 for SPA, respectively. Only the odds ratio for the lowest quartile of QCT (10.7) was found to be significant (P<.01). Receiver operating characteristic curves were calculated for each modality, with QCT showing the greatest area under the curve (0.70), followed by DPA (0.67) and SPA (0.60). The authors' results show that QCT and DPA are sensitive in discriminating mild from advanced forms of osteoporosis, whereas SPA has limited discriminatory capability

  11. A validated and densitometric HPTLC method for the simultaneous quantification of reserpine and ajmalicine in Rauvolfia serpentina and Rauvolfia tetraphylla

    Directory of Open Access Journals (Sweden)

    Devendra Kumar Pandey

    Full Text Available ABSTRACT High performance thin layer chromatographic method (HPTLC has been developed for the quantification of reserpine and ajmalicine in root part of two different population of Rauvolfia serpentina (L. Benth. ex Kurz and Rauvolfia tetraphylla L., Apocynaceae, collected from Punjab and Uttarakhand. HPTLC of methanolic extract of root containing indole alkaloids, i.e., reserpine and ajmalicine, was performed on TLC Silicagel 60 F254 (10 cm × 10 cm plates with toluene:ethyl acetate:formic acid (7:2:1, as mobile phase. Quantification of the reserpine and ajmalicine was performed in the absorption–reflection mode at 268 nm. The recovery of reserpine and ajmalicine were 99.3 and 98.7% respectively. The calibration curves were linear for both the reserpine and ajmalicine, in the range of 200–1200 ng. HPTLC densitometry has been performed for the estimation of reserpine and ajmalicine in root part of R. serpentina and R. tetraphylla for the first time. The method is simple, rapid and cost effective and can be used for routine analysis of ajmalicine and reserpine in different Rauvolfia species as well as for quality control of herbal drugs containing Rauvolfia species.

  12. ST6Gal1, Cox-2 and HB-EGF mRNA Expression in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Aliakbar Taherian

    2015-01-01

    Full Text Available Background: ST6Gal1, Cox-2 and HB-EGF genes are involved in different tumors and their enhanced expressions often correlate with poor prognosis. In this study we assay the expressions of these genes by reverse transcriptase-PCR in 54 breast cancer samples. Methods: Tissue samples were either formalin-fixed for histopathological examination or frozen for reverse transcriptase-PCR. Image program was used for the densitometry of the image of the gels and the expression of different genes was normalized with beta actin expression. The student's t-test and correlation matrix were used for data analyses. Results: We observed significantly higher expressions of ST6Gal1 (P= 0.040, Cox- 2 (P= 0.001 and HB-EGF (P= 0.009 in the tumor region compared to the margin samples. A significant correlation was found between HB-EGF and Cox-2 expression (P= 0.001. There was a positive correlation between total score, tumor size, histology grade and nuclear grade but there was a reverse correlation between age and tumor size, histology grade and total score. Conclusion: Expressions of ST6Gal1, Cox-2 and HB-EGF in breast tumor samples in this and a number of other studies emphasize their role as important markers in breast cancer. The use of medications to inhibit either their individual expressions or the possible inhibition of all three genes may improve patient survival and prevent metastasis.

  13. THE DIFFERENCES OF BONE METABOLISM IN MALES WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE AND POSTMENOPAUSAL FEMALES

    Directory of Open Access Journals (Sweden)

    O. A. Mardanova

    2014-07-01

    Full Text Available Aim — to compare bone metabolism activity in males with chronic obstructive pulmonary disease (COPD and postmenopausal females.Materials and methods. The prospective cohort study was conducted. 33 male patients with COPD over 55 years old and 33 female patients without respiratory diseases over 55 were included. General examination, clinical and biochemical blood analyses, densitometry of lumbar spine and proximal part of left femoral bone, respiratory function, osteocalcin and C-telopeptids blood levels have been performed to the patients.Results. Male patients with COPD had lower T-score for the femoral neck than postmenopausal female patients without pulmonary disorders,(–1.05 ± 0.85 SD and –0.36 ± 1.24 SD respectively, р < 0.05. Osteocalcin level in males with COPD was significantly higher and C‑telopeptids level was significantly lower than in postmenopausal females (р < 0.05.Conclusion. Male patients with COPD have lower T‑score for the femoral neck than postmenopausal females without pulmonary disorders of the same age. Furthermore osteoclasts in COPD patients seem to be more activated than in postmenopausal females, on the contrary osteoblasts activity is significantly depressed. Therefore it is necessary to use another approach of prevention and treatment of osteoporosis in patients with COPD.

  14. Nutrition in inflammatory bowel disease

    Science.gov (United States)

    Martínez Gómez, María Josefa; Melián Fernández, Cristóbal; Romeo Donlo, María

    2016-07-12

    Inflammatory bowel disease (IBD) is a chronic pathology that has an outbreaks course that in recent years have seen an increase in incidence, especially at younger ages. Malnutrition is frequently associated with this condition, therefore, it is very important to ensure a right nutritional intervention, especially in pediatric patients, to ensure an optimal growth and also an improvement in the clinic. Our goal will be updated the role of nutrition in this disease and in its treatment based on the published evidence. Malnutrition in these patients is frequent and is influenced by various factors such as, decreased food intake, increased nutrient requirements, increased protein loss and malabsorption of nutrients. Therefore there should be a nutritional monitoring of all of them, in which anthropometric measurements, laboratory tests and densitometry were made to establish the needs and sufficient caloric intake tailored to each patient. The use of enteral nutrition as a treatment in Crohn’s disease with mild to moderate outbreak in child population, is amply demonstrated, has even shown to be superior to the use of corticosteroids. Therefore we can conclude by stressing that nutritional intervention is a mainstay in the management of patients with IBD, which aims to prevent and / or control disease-related malnutrition to decrease morbidity and mortality and improve quality of life.

  15. A case of pathological rib fractures: focal osteolysis or osteoporosis?

    Science.gov (United States)

    Vrbanić, T S L; Novak, S; Sestan, B; Tudor, A; Gulan, G

    2008-03-01

    This paper reports on a unique, previously unreported, successful outcome in the case of a patient with focal osteolytic lesions of the ribs as a first sign of osteoporosis. The lesions were detected by chance after acute cough-induced rib fractures were seen on plain chest radiographs. The diagnosis had to be approached as a diagnosis of exclusion since known causes of the osteolytic process had to be eliminated. The authors describe multiple focal osteolytic lesions with rib fractures appearing in a pattern that could be confused with metastases. Laboratory results were normal. Final diagnosis was based on plain radiography, bone scan and bone densitometry. Pharmacomedical treatments for osteoporosis were applied. The patient was observed between the year 2000 and 2005. Five years later radiological and bone scintigraphy revealed resolution of the lesion. We conclude that osteoporosis should be included in the differential diagnosis of asymptomatic focal osteolysis of the ribs with rib fractures as a complication of acute cough. The case suggests that focal osteolytic lesions of the ribs may regress over time and become scintigraphically inactive.

  16. Assessment of multi-wavelength pulse photometry for non-invasive dose estimation of circulating drugs and nanoparticles

    Science.gov (United States)

    Adhikari, Pratik; Eklund, Wakako; Sherer, Eric A.; O'Neal, D. Patrick

    2016-03-01

    The feasibility of multi-wavelength photoplethysmography for the real-time sensing of absorptive and scattering agents in pulsatile blood is discussed. The use of pulsatile signals extracted from trans-illumination of an accessible section of tissue allows us to calculate the concentration of the optically extinctive species in the pulsatile blood. This technology, initially used for pulse oximetry and dye densitometry, can be applied to monitor in vivo concentration and clearance of various absorptive species. Recently, our prototype has been used monitor the concentration of therapeutic gold nanoparticles, antimalarial quinine, and the antifungal agent amphotericin B. The assessment of the optical properties, device specifications, and signal quality for each compound are presented. We observe that this technology can be used to monitor numerous extinctive drug and nano-materials that present features in the 350-1100 nm range. The rationale for using this technology in a clinical setting would be to improve outcomes by real-time pharmacological feedback and/or control at point of care in addition to the elimination of invasive blood draws for collection of data.

  17. Simultaneous HPTLC determination of strychnine and brucine in strychnos nux-vomica seed

    Directory of Open Access Journals (Sweden)

    Abid Kamal

    2012-01-01

    Full Text Available Objective: A simple, sensitive, and specific thin layer chromatography (TLC densitometry method has been developed for the simultaneous quantification of strychnine and brucine in the seeds of Strychnos nux-vomica. Materials and Methods: The method involved simultaneous estimation of strychnine and brucine after resolving it by high performance TLC (HPTLC on silica gel plate with chloroform-methanol-formic acid (8.5:1.5:0.4 v/v/v as the mobile phase. Results: The method was validated as per the ICH guidelines for precision (interday, intraday, intersystem, robustness, accuracy, limit of detection, and limit of quantitation. The relationship between the concentration of standard solutions and the peak response was linear within the concentration range of 50-1000 ng/spot for strychnine and 100-1000 ng/spot for brucine. The method precision was found to be 0.58-2.47 (% relative standard deviation [RSD] and 0.36-2.22 (% RSD for strychnine and brucine, respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.75% for strychnine and 100.52% for brucine, respectively. Conclusions: The HPTLC method for the simultaneous quantification of strychnine and brucine was found to be simple, precise, specific, sensitive, and accurate and can be used for routine analysis and quality control of raw material of S. nux-vomica and several unani and ayurvedic formulations containing this as an ingredient.

  18. Mutiple Spontaneous Rib Fractures in Patient with Cushing's Syndrome.

    Science.gov (United States)

    Lee, Hyun Jung; Je, Ji Hye; Seo, Ji Hye; Na, Young Ju; Yoo, Hye Jin

    2014-11-01

    Glucocorticoid (GC) excess, including Cushing's syndrome, is a common cause of secondary osteoporosis. Thirty to fifty percent of Cushing's syndrome patients experience non-traumatic fractures, which is often the presenting manifestation of Cushing's syndrome. However, there have been rare cases of Cushing's syndrome diagnosed only based upon bone manifestations. We describe a case of Cushing's syndrome that was diagnosed in a 44-year-old woman who initially visited our hospital due to multiple non-traumatic rib fractures. She did not exhibit any other manifestations of Cushing's syndrome such as moon face, buffalo hump or abdominal striae. Initially, we evaluated her for bone metastases from a cancer of unknown origin, but there was no evidence of metastatic cancer. Instead, we found a left adrenal incidentaloma. As a result of the hormone study, she was diagnosed as having Cushing's syndrome. Interestingly, her bony manifestation of Cushing's syndrome, which was evident in the bone scan and bone mineral densitometry, completely recovered after a left adrenalectomy. Therefore, the possibility of Cushing's syndrome as a cause of secondary osteoporosis should be considered in young patients with non-traumatic multiple fractures, with or without any other typical features of Cushing's syndrome.

  19. Spontaneous rib fractures.

    Science.gov (United States)

    Katrancioglu, Ozgur; Akkas, Yucel; Arslan, Sulhattin; Sahin, Ekber

    2015-07-01

    Other than trauma, rib fracture can occur spontaneously due to a severe cough or sneeze. In this study, patients with spontaneous rib fractures were analyzed according to age, sex, underlying pathology, treatment, and complications. Twelve patients who presented between February 2009 and February 2011 with spontaneous rib fracture were reviewed retrospectively. The patients' data were evaluated according to anamnesis, physical examination, and chest radiographs. The ages of the patients ranged from 34 to 77 years (mean 55.91 ± 12.20 years), and 7 (58.4%) were male. All patients had severe cough and chest pain. The fractures were most frequently between 4th and 9th ribs; multiple rib fractures were detected in 5 (41.7%) patients. Eight (66.7%) patients had chronic obstructive pulmonary disease, 2 (16.7%) had bronchial asthma, and 2 (16.7%) had osteoporosis. Bone densitometry revealed a high risk of bone fracture in all patients. Patients with chronic obstructive pulmonary disease or bronchial asthma had been treated with high-dose steroids for over a year. Spontaneous rib fracture due to severe cough may occur in patients with osteoporosis, chronic obstructive pulmonary disease, or bronchial asthma, receiving long-term steroid therapy. If these patients have severe chest pain, chest radiography should be performed to check for bone lesions. © The Author(s) 2015.

  20. Hyperdense dots mimicking microcalcifications : Mammographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nam Hyeon; Park, Jeong Mi; Goo, Hyun Woo; Bang, Sun Woo [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1996-12-01

    To differentiate fine hyperdense dots mimicking microcalcifications from true microcalcifications on mammography. Mammograms showing hyperdense dots in ten patients (mean age, 59 years) were evaluated. Two radiologists were asked to differentiate with the naked eye the hyperdense dots seen on ten mammograms and proven microcalcifications seen on ten mammograms. Densitometry was also performed for all lesions and the contrast index was calculated. The shape and distribution of the hyperdense dots were evaluated and enquires were made regarding any history of breast disease and corresponding treatment. Biopsies were performed for two patients with hyperdense dots. Two radiologists made correct diagnoses in 19/20 cases(95%). The contrast index was 0.10-0.88 (mean 0.58) for hyperdense dots and 0.02-0.45 (mean 0.17) for true microcalcifications. The hyperdense dots were finer and homogeneously rounder than the microcalcifications. Distribution of the hyperdense dots was more superficial in subcutaneous fat (seven cases) and subareolar area (six cases). All ten patients with hyperdense dots had history of mastitis and abscesses and had been treated by open drainage (six cases) and/or folk remedy (four cases). In eight patients, herb patches had been attached. Biopsies of hyperdense dots did not show any microcalcification or evidence of malignancy. These hyperdense dots were seen mainly in older patients. Their characteristic density, shape, distribution and clinical history makes differential diagnosis from true microcalcifications easy and could reduce unnecessary diagnostic procedures such as surgical biopsy.

  1. A DICOM based PACS for nuclear medicine

    International Nuclear Information System (INIS)

    Lassmann, M.; Reiners, C.

    2002-01-01

    The installation of a radiology information system (RIS) connected to a hospital information system (HIS) and a picture archiving and communications system (PACS) seems mandatory for a nuclear medicine department in order to guarantee a high patient throughput. With these systems a fast transmission of reports, images to the in- and out-patients' wards and private practitioners is realized. Therefore, since April 2000, at the department of nuclear medicine of the university of Wuerzburg a completely DICOM based PACS has been implemented in addition to the RIS. With this system a DICOM based workflow is realized throughout the department of nuclear medicine for reporting and archiving. The PACS is connected to six gamma-cameras, a PET scanner, a bone densitometry system and an ultrasound device. The volume of image data archived per month is 4 GByte. Patient demographics are provided to the modalities via DICOM-Worklist. With these PACS components a department specific archive purely based on DICOM can be realized. During the installation process problems occurred mainly because of the complex DICOM standard for nuclear medicine. Related to that is the problem that most of the software implementations still contain bugs or are not adapted to the needs of a nuclear medicine department (particularly for PET). A communication software for the distribution of nuclear medicine reports and images based on techniques used for the worldwide web is currently tested. (orig.) [de

  2. Serum protein identification and quantification of the corona of 5, 15 and 80 nm gold nanoparticles

    International Nuclear Information System (INIS)

    Schäffler, Martin; Semmler-Behnke, Manuela; Takenaka, Shinji; Wenk, Alexander; Schleh, Carsten; Johnston, Blair D; Kreyling, Wolfgang G; Sarioglu, Hakan; Hauck, Stefanie M

    2013-01-01

    When nanoparticles (NP) enter the body they come into contact with body fluids containing proteins which can adsorb to their surface. These proteins may influence the NP interactions with the biological vicinity, eventually determining their biological fate inside the body. Adsorption of the most abundantly binding proteins was studied after an in vitro 24 hr incubation of monodisperse, negatively charged 5, 15 and 80 nm gold spheres (AuNP) in mouse serum by a two-step analysis: proteomic protein identification and quantitative protein biochemistry. The adsorbed proteins were separated from non-adsorbed proteins by centrifugation and gel electrophoresis and identified using a MALDI-TOF-MS-Proteomics-Analyzer. Quantitative analysis of proteins in gel bands by protein densitometry, required the focus on predominantly binding serum proteins. Numerous proteins adsorbed to the AuNP depending on their size, e.g. apolipoproteins or complement C3. The qualitative and quantitative amount of adsorbed proteins differed between 5, 15 and 80 nm AuNP. Band intensities of adsorbed proteins decreased with increasing AuNP sizes based not only on their mass but also on their surface area. Summarizing, the AuNP surface is covered with serum proteins containing transport and immune related proteins among others. Hence, protein binding depends on the size, surface area and curvature of the AuNP. (paper)

  3. Preparation of a homogeneous extract of human growth hormone, isohormone B, and its 125I-labelling for utilization in radioligand assays

    International Nuclear Information System (INIS)

    Santos, A.J. dos.

    1985-01-01

    Non-destructive polyacrylamide gel electrophoretic (PAGE) tecnique, with direct UV-densitometry, was set up to permit both qualitative and quantitative studies of human growth hormone (hGH) isohormone purification is presented. This tecnique was used on a preparative scale to obtain milligram amounts of the fundamental form of hGH, isohormone B(Ih-B). Reversed electrophoresis was employed to elute the protein band form the gel. Retention of bio-and immunoactivity was demonstrated via two separate experiments. An 'in vivo' bioassay, based on the weight increase of hypophysectomized rats with a 2 x 2 factorial assay design, was used to compare the true somatotrophic activity of an hGH preparation submitted to the purification process with that of a single control preparation. Retention of immunoactivity was confirmed by studying the antibody binding properties of purified and radioiodinated Ih-B and by determination of its absolute immunopotency against a calibrated secondary standard. Radioimmuno assay curves, determined using Ih-B, as a standard and labelled preparation, showed its applicability in setting up assays based on more homogeneous reagents. (Author) [pt

  4. Effect of the menstrual cycle in ethanol pharmacokinetics.

    Science.gov (United States)

    Haddad, L; Milke, P; Zapata, L; de la Fuente, J R; Vargas-Vorácková, F; Lorenzana-Jiménez, M; Corte, G; Tamayo, J; Kaplan, M; Márquez, M; Kershenobich, D

    1998-01-01

    Differences in ethanol pharmacokinetics within the menstrual cycle have previously been reported and attributed to variations in body composition, hormonal influences and gastric emptying. To establish the role of the menstrual cycle in ethanol pharmacokinetics associated with changes in body composition, ethanol blood concentrations were measured in nine healthy women during the midfollicular (P1, days 8-10) and midluteal (P2, days 22-24) phases of the menstrual cycle after a postprandial oral ethanol dose (0.3 g kg(-1)). Total body water was assessed by dual-energy x-ray densitometry (DEXA) on both occasions. Median total body water did not vary during either phase of the menstrual cycle (P1 = 54.54%, P2 = 54.66%; P = 0.9296). Median area under the ethanol concentration-time curve (AUC) was lower during P1 (215.33 mg.h dl(-1)) than during P2 (231.33 mg.h dl(-1))(P = 0.8253). No significant differences were found on ethanol pharmacokinetics in either phase of the menstrual cycle.

  5. Status of prompt gamma neutron activation analysis (PGAA) at TRR-1/M1 (Thai Research Reactor-1/Modified 1)

    Energy Technology Data Exchange (ETDEWEB)

    Asvavijnijkulchai, Chanchai; Dharmavanij, Wanchai; Siangsanan, Pariwat; Ratanathongchai, Wichian; Chongkum, Somporn [Physics Division, Office of Atomic Energy for Peace, Vibhavadi Rangsit Road, Chatuchak, Bangkok (Thailand)

    1999-08-01

    The first prompt gamma activation analysis (PGAA) was designed, constructed and installed at a 6 inch diameter neutron beam port of the Thai Research Reactor-1/Modified 1 (TRR-1/M1) since 1989. Beam characteristic were made by Gd foil irradiation, X-ray film exposing and densitometry scanning consequently. The thermal neutron flux at sample position was measured by Au foil activation, and was about 1 x 10{sup 7} n.cm{sup 2}.sec{sup -1} at 700 kW operating power. The experiments have been conducted successfully. In 1998, the PGAA facility has been developed for the reactor operating power at 1.2 MW. The new PGAA system, e.g., beam shutter, gamma collimator and biological shields have been designed to reduce the leakage of neutrons and gamma radiation to the acceptance levels in accordance with the International Commission on Radiation Protection Publication 60 (ICRP 60). The construction and installation will be completed in April 1999. (author)

  6. The clinical determination of absolute density in bone utilizing single and dual energy compton scattering

    International Nuclear Information System (INIS)

    Huddleston, A.L.; Weaver, J.

    1980-01-01

    Several methods important in the clinical diagnosis of skeletal diseases have been proposed for the determination of bone mass, such as photon absorptiometry, computed tomography, and neutron activation. None of these present methods provides for the determination of the physical density of bone. In the Radiological Physics Research Laboratory at the University of Virginia, the principles of Compton scattering are being investigated with the intent of determining the electron density and the physical density of human bone. A Compton-scatter densitometer has been constructed for the in vivo density determination of the femoral head. This technique utilizes of collimated low energy gamma source and detector system. The method has been tested in cadavers and in known density samples and has an accuracy of 2 %. A second densitometer has been designed for the in vivo determination of electron density of the vertebrae based upon a new technique which employs dual energy Compton scattering in the spinal column. These systems will be discussed; and the principles of dual energy Compton scatter densitometry will be presented. The importance of these isotope techniques and the feasibility of in vivo density determination in the vertebrae and femoral head will be discussed as they relate to clinical diagnosis and research. (author)

  7. Effect of smoking cessation on quantitative computed tomography in smokers at risk in a lung cancer screening population

    International Nuclear Information System (INIS)

    Jobst, Bertram J.; Eichinger, Monika; Wielpuetz, Mark O.; Weinheimer, Oliver; Trauth, Mila; Kauczor, Hans-Ulrich; Becker, Nikolaus; Motsch, Erna; Gross, Marie-Luise; Eigentopf, Anke; Tremper, Jan; Delorme, Stefan

    2018-01-01

    To longitudinally evaluate effects of smoking cessation on quantitative CT in a lung cancer screening cohort of heavy smokers over 4 years. After 4 years, low-dose chest CT was available for 314 long-term ex-smokers (ES), 404 continuous smokers (CS) and 39 recent quitters (RQ) who quitted smoking within 2 years after baseline CT. CT acquired at baseline and after 3 and 4 years was subjected to well-evaluated densitometry software, computing mean lung density (MLD) and 15th percentile of the lung density histogram (15TH). At baseline, active smokers showed significantly higher MLD and 15TH (-822±35 and -936±25 HU, respectively) compared to ES (-831±31 and -947±22 HU, p<0.01-0.001). After 3 years, CS again had significantly higher MLD and 15TH (-801±29 and -896±23 HU) than ES (-808±27 and -906±20 HU, p<0.01-0.001) but also RQ (-813±20 and -909±15 HU, p<0.05-0.001). Quantitative CT parameters did not change significantly after 4 years. Importantly, smoking status independently predicted MLD at baseline and year 3 (p<0.001) in multivariate analysis. On quantitative CT, lung density is higher in active smokers than ex-smokers, and sustainably decreases after smoking cessation, reflecting smoking-induced inflammation. Interpretations of quantitative CT data within clinical trials should consider smoking status. (orig.)

  8. Enhanced biofilm formation and melanin synthesis by the oyster settlement-promoting Shewanella colwelliana is related to hydrophobic surface and simulated intertidal environment.

    Science.gov (United States)

    Mitra, Sayani; Gachhui, Ratan; Mukherjee, Joydeep

    2015-01-01

    A direct relationship between biofilm formation and melanogenesis in Shewanella colwelliana with increased oyster recruitment is already established. Previously, S. colwelliana was grown in a newly patented biofilm-cultivation device, the conico-cylindrical flask (CCF), offering interchangeable hydrophobic/hydrophilic surfaces. Melanization was enhanced when S. colwelliana was cultivated in a hydrophobic vessel compared with a hydrophilic vessel. In the present study, melanogenesis in the CCF was positively correlated with increased architectural parameters of the biofilm (mean thickness and biovolume obtained by confocal laser scanning microscopy) and melanin gene (melA) expression observed by densitometry. Niche intertidal conditions were mimicked in a process operated in an ultra-low-speed rotating disk bioreactor, which demonstrated enhanced biofilm formation, melanogenesis, exopolysaccharide synthesis and melA gene expression compared with a process where 12-h periodic immersion and emersion was prevented. The wettability properties of the settling plane as well as intermittent wetting and drying, which influenced biofilm formation and melA expression, may affect oyster settlement in nature.

  9. Electrospinning of Nano-Porous Cellulose Acetate Fibers Under Humidified Condition

    Directory of Open Access Journals (Sweden)

    Hamid Fattahi Juybari

    2016-01-01

    Full Text Available Electrospinning as a simple method was used to produce cellulose acetate porous fibers. Motivation for production of fibers with small diameter in the submicron and nano scales was to achieve the material with a large surfacearea with porosity formation in the structure of electrospun fibers. In this study, porous cellulose acetate (CA fibers were produced by electrospinning process from solution of CA/acetone/water. The porosity of the fiber was controlled by adjustment of the temperature and humidity of electrospinning chamber. Scanning electron microscopy (SEM and densitometry were employed to evaluate the morphology and porosity of the samples. The results showed that the morphology and porosity of cellulose acetate fibers depend on the polymer solution concentration and relative humidity of electrospinning atmosphere. Cellulose acetate fibers were electrospun best at the concentrations of 12 to 18 wt% and relative humidity range of 40 to 80%. The highest porosity was obtained at the relative humidity of 80% and concentration of 15 wt%. In addition, by increasing the relative humidity of electrospinning environment and polymer concentration, the average diameter of the fibers was increased. With increasing the polymer concentration, there was less likelihood in thermodynamic instability and phase separation. In contrast, increases in relative humidity led to diffusion of more water into the electrospinning jet, giving rise to phase separation. Our observations revealed that the skin of fibers was formed at the earlier stage of the process and prevented the stretch in electrospinning jet.

  10. Analysis of Wheat Prolamins, the Causative Agents of Celiac Sprue, Using Reversed Phase High Performance Liquid Chromatography (RP-HPLC and Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS

    Directory of Open Access Journals (Sweden)

    Jaime H. Mejías

    2014-04-01

    Full Text Available Wheat prolamins, commonly known as “gluten”, are a complex mixture of 71–78 proteins, which constitute ~80% of the proteins in the wheat grains and supply 50% of the global dietary protein demand. Prolamins are also responsible for numerous gluten-induced disorders and determine the unique visco-elastic properties of the wheat dough. These properties necessitate the reliable determination of the prolamin composition in wheat grains and their derived products. Therefore, this study examined the impact of HPLC conditions, including column type, column temperature, flow rate, and the gradient of polar and non-polar solvents in the mobile phase, to improve the analytical resolution of prolamins. The following conditions were found optimal for analyses: column temperature 60 °C, flow rate 1.0 mL/min and an elution gradient of 20%–60% of 0.1% trifluoroacetic acid + acetonitrile in 60 min. For further improvement of resolution, gliadin and glutenin extracts were analyzed using MALDI-TOF-MS in combination with HPLC fractionation. Two semi-quantitative methods, densitometry of stained polyacrylamide gels and HPLC, were used to determine relative prolamin quantities and the correspondence between the methods was established. The combinatorial gluten analyses approach developed during the present study was used to analyze prolamin profiles of wheat transformants expressing DEMETER silencing artificial microRNA, and the results are discussed.

  11. BIOCHEMICAL MARKERS OF BONE RESORPTION AND HORMONAL REGULATION OF BONE METABOLISM FOLLOWING LIVER TRANSPLANTATION

    Directory of Open Access Journals (Sweden)

    V. P. Buzulina

    2013-01-01

    Full Text Available Aim. Comparative evaluation of two biochemical markers of bone resorption and hormonal regulation of bone metabolism in liver recipients. Methods and results. Bоne densitometry of L2–L4 and neck of femur, serum level of some hormones (PTH, vitamin D3, estradiol, testosterone regulating osteoclastogenesis as well as com- parative analyses of two bone resorption markers β-crosslaps and tartrate-resistant acid phosphatase type 5b (TRAP-5b were fulfilled in patients after orthotopic liver transplantation (OLT. In 1 month after OLT bone density reduction of L2–L4 and neck of femur; decrease of vitamin D3, estradiol in women, testosterone in men and increase levels of bone resorption markers were observed. In 1 and 2 years after OLT the rise of bone density, increased levels of PTH, estradiol, testosterone and decreased β-crosslaps levels were revealed, while vitamin D3 and TRAP-5b levels remained stable. Conclusion. TRAP-5b was found to be a more speciffic marker of bone resorption, independent from collagen metabolism in liver. Osteoporosis defined in long-term period after OLT was associated with higher TRAP-5b and revialed in women with low estradiol level. 

  12. High prevalence of osteoporosis in Saudi men

    International Nuclear Information System (INIS)

    El-Desouki, Mahmoud I.; Sulimani, Riyadh A.

    2007-01-01

    Objective was to determine the prevalence of osteoporosis in healthy Saudi men. We randomly recruited 429 Saudi men from the community. The recruited Saudi men were subjected to an interview to reveal their lifestyle parameters, calcium intake and level of activity. Bone densitometry was assessed at lumbar spine (L-4) and the femoral neck. The dual x-ray absorptiometry (DXA) scan was carried out in the Nuclear Medicine at King Khalid University Hospital, Riyadh, Saudi Arabia from September 2002 to December 2004. The World Health Organization definition of low bone mineral density was used. Poor oral calcium intake and low level of daily activity were noted. The overall prevalence of osteopenia for the lumbar spine in the whole group was 35.7% while osteoporosis was present in 21.4% of the subjects. In the femoral neck, osteopenia was noted in 38% and osteoporosis in 11.4%. When either lumbar spine or femoral neck osteoporosis is used for diagnosis, the prevalence of osteoporosis rises to 23.5%. Within the whole group, osteopenia and osteoporosis were more common in individuals above the age of 50 than those below 50 years old. Low bone mineral density occurs with high frequency in Saudi men. Lumbar spine appears to be affected to a higher degree. The reason for the high prevalence of osteoporosis in Saudi men is unclear. Possible underlying causes include nutritional, life style and genetic factors. (author)

  13. Determination of peak bone mass density and composition in low-income urban residents of metro Manila using isotope techniques

    International Nuclear Information System (INIS)

    Lim-Abrahan, M.A.V.; Guanzon, L.V.V.; De Guzman, A.M.; Villaruel, C.M.; Santos, F.

    1996-01-01

    Filipinos are predisposed to osteoporosis because of inadequate calcium in their diet early on in life, confounded by malnutrition, susceptibility to infectious diseases and their generally small body frame. And yet the problem of osteoporosis has not been properly addressed. The incidence of osteoporosis is not known since oftentimes it is established only once complications have set in. It is believed that osteoporosis poses a public health concern but its extent is not realized at present because of lack of local epidemiological data. This study aims to determine the bone mass density as a function of age among 210 screened and healthy volunteers coming from urban poor communities of Metro Manila over a 3-year period. A LUNAR DPX-L bone densitometry for dual X-ray photon absorptiometry will be used, with measurements taken on the spine and femur. It also aims to correlate factors such as nutritional intake, physical activity, lifestyle, sex and body mass index with that of bone mass density. Blood and urine samples will be obtained for biochemistry and hormonal radioimmunoassay examination. Statistical analysis will be done to com are differences within the group and to determine rate of bone loss as a function of age and sex. Plans for future research include the determination of trace element content in cortical bone and tooth samples from healthy living subjects. (author)

  14. Primary hyperparathyroidism: recent advances.

    Science.gov (United States)

    Walker, Marcella D; Bilezikian, John P

    2018-07-01

    The purpose of this review is to describe recent advances and changes in the evaluation and management of primary hyperparathyroidism (PHPT). Although it has long been recognized that asymptomatic PHPT is associated with bone loss, particularly at cortical skeletal sites when evaluated with dual-energy X-ray absorptiometry, new imaging techniques suggest that trabecular skeletal deterioration as well as clinically silent vertebral fractures and nephrolithiasis are common. Nonclassical targets of asymptomatic PHPT as well as the effect of vitamin D deficiency and treatment upon PHPT presentation have been the subject of recent intense investigation. Randomized clinical trials are now available regarding the effect of parathyroidectomy (PTX) upon both classical and nonclassical target organs. They have confirmed results from observational studies with regard to the skeletal benefits of PTX but have not consistently shown improvements in nonclassical symptoms. These findings have led to recommendations for more extensive renal and skeletal evaluation and broader criteria for PTX in PHPT. In addition to dual-energy X-ray absorptiometry, vertebral and renal imaging is recommended. When available, trabecular imaging techniques may be helpful. PTX criteria now include subclinical kidney stones, vertebral fractures and hypercalciuria, in addition to those based on age, serum calcium, bone densitometry and renal function.

  15. Improving Materials Accountancy for Reprocessing using hiRX

    International Nuclear Information System (INIS)

    Cipiti, B.; McDaniel, M.; Havrilla, G.

    2015-01-01

    The High Resolution X-ray (hiRX) technology has the potential to replace K-Edge and Hybrid K-Edge Densitometry (HKED) for routine accountability measurements in reprocessing. This technology may significantly reduce plutonium measurement uncertainty in a simpler and less costly instrument. X-ray optics are used to generate monochromatic excitation of a sample and selectively collect emitted X-rays of the target elements. The result is a spectrum with a peak specific to one element with negligible background. Modeling was used to examine how safeguards could be improved through the use of hiRX at existing aqueous reprocessing plants. This work utilized the Separation and Safeguards Performance Model (SSPM), developed at Sandia National Laboratories, to examine how reduced measurement uncertainty decreases the overall inventory difference measurement error. Material loss scenarios were also modelled to determine the effect on detection probability for protracted diversion of nuclear material. Current testing of hiRX is being used to inform the modelling effort, but a 0.1% measurement uncertainty for uranium and plutonium concentration is an optimistic goal based on laboratory results. Modeling results showed that a three-fold improvement in the ability to detect a protracted diversion of plutonium may be possible if the 0.1% uncertainty goal can be achieved. The modelling results will be presented along with a discussion of the current experimental campaign results. In addition, a qualitative cost analysis will be presented to compare the use of hiRX with HKED. (author)

  16. STABILITAS EPIGALOKATEKIN GALAT DALAM KRIM EKSTRAK TEH HIJAU DENGAN VARIASI KONSENTRASI ANTIOKSIDAN VITAMIN C 1% DAN VITAMIN E 1%

    Directory of Open Access Journals (Sweden)

    Nining Sugihartini

    2016-11-01

    Full Text Available Epigallocatechingallate (EGCG in green tea extract has activity as an anti-inflammatory agent. On the other hand the stability of EGCG is poor because of the oxidation. The aim of this study was to determine the influence of Vitamine C and Vitamine E in formulation of green tea extract cream to the stabiliy of EGCG. The green tea extract was obtained from the extraction process by infundation followed by fractination with ethyl acetate as the solvent. The three formulas were compiled in similar composition with the concentration of vitamine C 1% (FI, Vitamine E 1% (FII and there was no Vitamine C and Vitamine E (FIII as a control. The EGCG level was determinated by TLC-densitometry methode. The stability parameter was determinated by calculated of the Q10 of each formula. The result of this study showed that the parameter of t90 of EGCG with Vitamine C 1%, Vitamine E 1% and control addition were 0.0108 hours, 0.0087 hours, 0.0084 hours, respectively. Stability of EGCG in green tea leaf extract cream with addition of the vitamin C 1% was higher than it stability with the addition of vitamin E 1%. The concentration of Vitamin C 1% was the optimum concentration as antioxidant in formulation of green tea extract cream.

  17. Formation of plasmid DNA strand breaks induced by low-energy ion beam: indication of nuclear stopping effects

    International Nuclear Information System (INIS)

    Chen Yu; Jiang Bingyao; Chen Youshan; Ding Xingzhao; Liu Xianghuai; Chen Ceshi; Guo Xinyou; Yin Guanglin

    1998-01-01

    Plasmid pGEM 3zf(+) was irradiated by nitrogen ion beam with energies between 20 and 100 keV and the fluence kept as 1 x 10 12 ions/cm 2 . The irradiated plasmid was assayed by neutral electrophoresis and quantified by densitometry. The yields of DNA with single-strand and double-strand breaks first increased then decreased with increasing ion energy. There was a maximal yield value in the range of 20-100 keV. The relationship between DNA double-strand breaks (DSB) cross-section and linear energy transfer (LET) also showed a peak-shaped distribution. To understand the physical process during DNA strand breaks, a Monte Carlo calculation code known as TRIM (Transport of Ions in Matter) was used to simulate energy losses due to nuclear stopping and to electronic stopping. It can be assumed that nuclear stopping plays a more important role in DNA strand breaks than electronic stopping in this energy range. The physical mechanisms of DNA strand breaks induced by a low-energy ion beam are also discussed. (orig.)

  18. Flow regime identification methodology with MCNP-X code and artificial neural network

    International Nuclear Information System (INIS)

    Salgado, Cesar M.; Instituto de Engenharia Nuclear; Schirru, Roberto; Brandao, Luis E.B.; Pereira, Claudio M.N.A.

    2009-01-01

    This paper presents flow regimes identification methodology in multiphase system in annular, stratified and homogeneous oil-water-gas regimes. The principle is based on recognition of the pulse height distributions (PHD) from gamma-ray with supervised artificial neural network (ANN) systems. The detection geometry simulation comprises of two NaI(Tl) detectors and a dual-energy gamma-ray source. The measurement of scattered radiation enables the dual modality densitometry (DMD) measurement principle to be explored. Its basic principle is to combine the measurement of scattered and transmitted radiation in order to acquire information about the different flow regimes. The PHDs obtained by the detectors were used as input to ANN. The data sets required for training and testing the ANN were generated by the MCNP-X code from static and ideal theoretical models of multiphase systems. The ANN correctly identified the three different flow regimes for all data set evaluated. The results presented show that PHDs examined by ANN may be applied in the successfully flow regime identification. (author)

  19. Restoration of strength despite low stress and abnormal imaging after Achilles injury.

    Science.gov (United States)

    Trudel, Guy; Doherty, Geoffrey P; Koike, Yoichi; Ramachandran, Nanthan; Lecompte, Martin; Dinh, Laurent; Uhthoff, Hans K

    2009-11-01

    To determine the usefulness of clinical imaging in predicting the mechanical properties of rabbit Achilles tendons after acute injury. We created a 2 x 7-mm full-thickness central tendon defect in one Achilles tendon of healthy rabbits. Rabbits in groups of 10 were killed immediately and 4 and 8 wk after surgery (n = 30). We then performed magnetic resonance (MR) imaging, ultrasonography (US), bone mineral densitometry (BMD), and mechanical testing to failure using a dual-cryofixation assembly on experimental and contralateral tendons. The main outcome measures included tendon dimensions, optical density (OD) of T1-weighted, proton density (PD), and T2-weighted MR sequences, US focal abnormalities, BMD of the calcaneus, and stress and peak load to failure. On MR imaging and US, all dimensions of the injured tendons after 2 wk and more were greater than those of the contralateral tendons (P tendons at both 4 wk (39 +/- 9 vs 77 +/- 16 N x mm(-2)) and 8 wk (58 +/- 6 vs 94 +/- 26 N x mm(-2); P tendons, higher T1-weighted OD correlated with lower peak load (r = -0.46; P tendon of lower stress. These findings support progressive physical loading 4 wk after an Achilles tendon injury. T1-weighted OD constituted a marker of tendon mechanical recovery.

  20. Relationship Between BMD and Prevalent Vertebral Fractures in Indian Women Older Than 50 Yr.

    Science.gov (United States)

    Gupta, Yashdeep; Marwaha, Raman K; Kukreja, Subhash; Bhadra, Kuntal; Narang, Archana; Mani, Kalaivani; Mithal, Ambrish; Tandon, Nikhil

    2016-01-01

    The purpose of the study was to study the relationship of morphometric vertebral fractures with bone mineral density (BMD) in Indian women older than 50 yr. Four hundred fifteen healthy Indian women older than 50 yr (mean age: 62.8 yr) underwent lateral X-rays of the lumbar and thoracic spine. Genant's semiquantitative method was used to diagnose and classify morphometric vertebral fractures. BMD was measured by DXA at lumbar spine and total hip. Recruited subjects underwent anthropometric, biochemical, and hormonal evaluation. Vertebral fractures were present in 17.1% (95% confidence interval: 13.5, 20.8) subjects. Prevalence of osteoporosis based on BMD was 35.7%. By adding those with prevalent fractures, the number of women requiring therapy for osteoporosis would increase to 46.5%. The BMD measured at femur neck, total hip, and lumbar spine (L1eL4) was not found to be lower in women with vertebral fractures as compared with those without fractures. BMD was not found to be lower in women with vertebral fractures as compared with those without fractures. Significant number of additional subjects with BMD in the normal or osteopenic range become eligible for osteoporosis treatment when presence of vertebral fracture is used as an independent indication for such treatment. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.