WorldWideScience

Sample records for da dose glandular

  1. Estimation of average glandular dose depending on the thickness of the breast; Estimativa da dose glandular media em funcao da espessura da mama

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: lessandra.pertile@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient.

  2. Estimating average glandular dose by measuring glandular rate in mammograms

    International Nuclear Information System (INIS)

    Goto, Sachiko; Azuma, Yoshiharu; Sumimoto, Tetsuhiro; Eiho, Shigeru

    2003-01-01

    The glandular rate of the breast was objectively measured in order to calculate individual patient exposure dose (average glandular dose) in mammography. By employing image processing techniques and breast-equivalent phantoms with various glandular rate values, a conversion curve for pixel value to glandular rate can be determined by a neural network. Accordingly, the pixel values in clinical mammograms can be converted to the glandular rate value for each pixel. The individual average glandular dose can therefore be calculated using the individual glandular rates on the basis of the dosimetry method employed for quality control in mammography. In the present study, a data set of 100 craniocaudal mammograms from 50 patients was used to evaluate our method. The average glandular rate and average glandular dose of the data set were 41.2% and 1.79 mGy, respectively. The error in calculating the individual glandular rate can be estimated to be less than ±3%. When the calculation error of the glandular rate is taken into consideration, the error in the individual average glandular dose can be estimated to be 13% or less. We feel that our method for determining the glandular rate from mammograms is useful for minimizing subjectivity in the evaluation of patient breast composition. (author)

  3. Evaluation of average glandular dose in digital and conventional systems of the mammography; Avaliacao da dose glandular media em sistemas digitais e convencionais de mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J., E-mail: alinecx90@gmail.com, E-mail: vsmdbarros@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Mello, Francisca A. de, E-mail: francissamello@yahoo.com.br [Hospital das Clinicas do Recife (HCR/UFPE), PE (Brazil)

    2014-07-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  4. Preliminary results of the average glandular dose to the breast with TLDS measure is computed as the conversion factors; Resultados preliminares da dose glandular media na mama medida com TLDS e calculada atraves de fatores de conversao

    Energy Technology Data Exchange (ETDEWEB)

    Sardo, Luiz T.L.; Almeida, Claudio D.; Coutinho, Celia M.C., E-mail: ltsardo@yahoo.com.br, E-mail: claudio@ird.gov.br, E-mail: celia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    At mammography exams there is a risk of a breast cancer induced from the absorbed dose by the glandular tissue. According to the National Institute of Cancer, INCA, breast cancer is the second type most frequent in the world and the most common among women, therefore the necessity of monitoring the mean glandular dose, D{sub G}. Measuring methods of D{sub G} were established by some authors. Among the established methods the method of Dance is one of the most known. In this study was utilized a measurement method realized with TL dosimeters inserted in a breast tissue equivalent phantom, BTE, with 46% of glandularity and exposed using Mo/Mo and Mo/Rh target/filter combination and 28kV. To ensure this measurement method the results were compared with a calculation method, used by Dance, of D{sub G} from the measurement of incident air kerma, K{sub i}, and conversion factors to consider mainly the beam quality, the compressed thickness and the glandularity of the breast. The results of the comparison of the D{sub G} measurement with the obtained dose by the method of Dance demonstrated that for the thickness of 4.0 and 6.0 cm the doses were consistent. For the thickness of 5.0 cm the difference was higher, indicating that the glandularity may influence, suggesting further investigation. (author)

  5. Comportamento da dose glandular versus contraste do objeto em mamografia: determinação de formalismo semi-empírico para diferentes combinações alvo-filtro Behavior of subject contrast versus glandular dose in mammography: determination of a semi-empirical formalism for different target-filter combinations

    Directory of Open Access Journals (Sweden)

    Gabriela Hoff

    2006-06-01

    Full Text Available OBJETIVO: Verificar o efeito da mudança no contraste do objeto, tempo de exposição e dose de radiação quando diferentes espessuras de filtração de molibdênio (Mo e ródio (Rh são empregadas em mamógrafos. MATERIAIS E MÉTODOS: Realizaram-se medidas da exposição na entrada da pele com uma câmara de ionização para diferentes espessuras para os filtros de Mo e Rh. Para determinar a dose glandular média foi utilizado simulador de BR12 (50% tecido adiposo e 50% tecido glandular de diferentes espessuras (4 cm e 8 cm. Energias na faixa de 24 kVp a 34 kVp foram empregadas e filmes Kodak MinR 2000 foram utilizados. RESULTADOS: Os resultados evidenciaram dados de contraste do objeto, dose glandular e tempo de exposição para diferentes espessuras de filtros adicionais e diferentes tensões. Esses dados indicaram aumento nos valores de contraste do objeto e tempo de exposição, com o aumento da espessura dos filtros. A dose glandular apresentou comportamento com diferentes tendências para cada caso analisado. Equações foram definidas para possibilitar a estimativa do contraste do objeto, dose glandular e tempo de exposição para os casos estudados. CONCLUSÃO: Os resultados possibilitaram a estimativa de equações que auxiliam na verificação do comportamento do contraste do objeto e da dose glandular para simuladores com espessura de 4 cm e 8 cm e para os filtros de Rh e Mo. Dessa forma, torna-se possível estimar a figura de mérito (razão entre o contraste do objeto e a dose glandular, podendo auxiliar na análise da relação risco-benefício dos casos estudados.OBJECTIVE: Our purpose was to verify the effect of changes in subject contrast, exposure time and radiation dose when different thicknesses of molybdenum (Mo and rhodium (Rh filters are used in mammography equipments. MATERIALS AND METHODS: Entrance skin exposure measurements were performed with an ionization chamber for different thicknesses of Mo and Rh filters

  6. Glandular dose and image quality control in mammography facilities with computerized radiography systems; Dose glandular e controle de qualidade da imagem em servicos de mamografia com sistema de radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Marcelino Vicente de Almeida

    2010-07-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  7. Average glandular dose in patients submitted to mammographic examinations

    International Nuclear Information System (INIS)

    Nogueira, M.S.; Silva, T.A. da; Oliveira, M. de; Joana, G.S.; Oliveira, A.L.K.

    2008-01-01

    Doses in mammography should be maintained as low as possible without reducing the high image quality needed to the early detection of the breast cancer. As the breast is composed of tissues with very soft composition and densities, it increases the difficulty to detect small changes in the normal anatomical structures that may be associated with breast cancer. To achieve the standards of resolution and contrast for mammography, the quality and intensity of the X-ray beam, the breast positioning and compression, the film screen system, and the film processing must be in optimal operational conditions. This study intended to evaluate the mean glandular dose of patients undergoing routine exams in one mammography unit. Patient image analyses were done by a radiologist doctor who took into account 10 evaluation criteria for each CC and MLO incidences. For estimating each patient glandular dose the radiographic technique parameters (kV and mAs) and the thickness of the compressed breast were recorded. European image quality criteria were adopted by the radiologist doctor to accept the image for diagnostic purpose. For breast densities of 50% adipose and 50% glandular tissues the incident air-kerma was measured and the glandular dose calculated considering the x-ray output during the exam. In the study of 50 patients the mean glandular dose varied from 0.90 to 3.27 mGy with a mean value of 1.98 mGy for CC incidences. For MLO incidences the mean glandular doses ranged from 0.97 to 3.98 mGy and a mean value of 2.60 mGy. (author)

  8. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  9. Development of an excel spreadsheet formean glandular dose in mammography

    International Nuclear Information System (INIS)

    Nagoshi, Kazuyo; Fujisaki, Tatsuya

    2008-01-01

    The purpose of this study was to develop an Excel spreadsheet to calculate mean glandular dose (D g ) in mammography using clinical exposure data. D g can be calculated as the product of incident air kerma (K a ) and D gN (i.e., D g =K a x D gN ). According to the method of Klein et al (Phys Med Biol 1997; 42: 651-671), K a was measured at the entrance surface with an ionization dosimeter. Normalized glandular dose (D gN ) coefficients, taking into account breast glandularity, were computed using Boone's method (Med Phys 2002; 29: 869-875). D gN coefficients can be calculated for any arbitrary X-ray spectrum. These calculation procedures were input into a Microsoft Excel spreadsheet. The resulting Excel spreadsheet is easy to use and is always applicable in the field of mammography. The exposure conditions concerning D g in clinical practice were also investigated in 22 women. Four exposure conditions (target/filter combination and tube voltage) were automatically selected in this study. This investigation found that average D g for each exposure was 1.9 mGy. Because it is recommended that quality control of radiation dose management in mammography is done using an American College of Radiology (ACR) phantom, information about patient dose is not obtained in many facilities. The present Excel spreadsheet was accordingly considered useful for optimization of exposure conditions and explanation of mammography to patients. (author)

  10. Evaluation of exposure in mammography: limitations of average glandular dose and proposal of a new quantity

    International Nuclear Information System (INIS)

    Geeraert, N.; Bosmans, H.; Klausz, R.; Muller, S.; Bloch, I.

    2015-01-01

    The radiation risk in mammography is traditionally evaluated using the average glandular dose. This quantity for the average breast has proven to be useful for population statistics and to compare exposure techniques and systems. However it is not indicating the individual radiation risk based on the individual glandular amount and distribution. Simulations of exposures were performed for six appropriate virtual phantoms with varying glandular amount and distribution. The individualised average glandular dose (iAGD), i.e. the individual glandular absorbed energy divided by the mass of the gland, and the glandular imparted energy (GIE), i.e. the glandular absorbed energy, were computed. Both quantities were evaluated for their capability to take into account the glandular amount and distribution. As expected, the results have demonstrated that iAGD reflects only the distribution, while GIE reflects both the glandular amount and distribution. Therefore GIE is a good candidate for individual radiation risk assessment. (authors)

  11. The study of mean glandular dose in mammography in Yazd and the factors affecting it

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Mostaar, A.; Ghasemi, A.; Ehramposh, M. H.; Khosravi, H.

    2006-01-01

    The objective of this study was to determine the mean glandular dose resulting from mammography examinations in Yazd, southeastern Iran and to identify the factors affecting it. Patients and Methods: This survey was conducted during May to December 2005 to estimate the mean glandular dose for women undergoing mammography and to report the distribution of dose. compressed breast thickness, glandular tissue content, and mammography technique used. The clinical data were collected from 946 mammograms taken from 246 women who were referred to four mammography centers. The mammography instruments in these centers were four modern units with a molybdenum anode and either molybdenum or rhodium filter. The exposure conditions of each mammogram were recorded. The breast glandular content of each mammogram was estimated by a radiologist. The mean glandular dose was calculated based on measuring the normalized entrance skin dose in air. half value layer, kVp, mAs, breast thickness and glandular content. Half value layer, kVp and entrance skin dose were measured by a solid-state detector. The analytical method of Sobol et al. was used for calculation of mean glandular dose . Results: The mean±SD mean glandular dose per film was.2±0.6 mGy for cranio caudal and 1.63±O.9 mGy for mediolateral oblique views. The mean±SD mean glandular dose per woman was 5.5 3.1.mGy. A positive correlation was found between the beam Half value layer with mean glandular dose (r=O.38) and the breast thickness with mean glandular dose (r=O.5). Conclusion: The mean±SD mean glandular dose per film of 1.42±0.8 mGy in present study was lower than most of similar reports. However, the mean mean glandular dose per woman was higher than that in other studies

  12. Average glandular dose in digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Olgar, T. [Ankara Univ. (Turkey). Dept. of Engineering Physics; Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2012-10-15

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  13. Average glandular dose in digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Olgar, T.; Universitaetsklinikum Leipzig AoeR; Kahn, T.; Gosch, D.

    2012-01-01

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  14. FORTRAN Code for Glandular Dose Calculation in Mammography Using Sobol-Wu Parameters

    Directory of Open Access Journals (Sweden)

    Mowlavi A A

    2007-07-01

    Full Text Available Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also has an effect on this calculation. Fatty or fibrous breasts would have a lower value for the glandular fraction than dense breasts. Breast tissue composed of half glandular and half adipose tissue would have a glandular fraction in between that of fatty and dense breasts. Therefore, the use of a computational code for average glandular dose calculation in mammography is a more effective means of estimating the dose of radiation, and is accurate and fast. Methods: In the present work, the Sobol-Wu beam quality parameters are used to write a FORTRAN code for glandular dose calculation in molybdenum anode-molybdenum filter (Mo-Mo, molybdenum anode-rhodium filter (Mo-Rh and rhodium anode-rhodium filter (Rh-Rh target-filter combinations in mammograms. The input parameters of code are: tube voltage in kV, half-value layer (HVL of the incident x-ray spectrum in mm, breast thickness in cm (d, and glandular tissue fraction (g. Results: The average glandular dose (AGD variation against the voltage of the mammogram X-ray tube for d = 4 cm, HVL = 0.34 mm Al and g=0.5 for the three filter-target combinations, as well as its variation against the glandular fraction of breast tissue for kV=25, HVL=0.34, and d=4 cm has been calculated. The results related to the average glandular absorbed dose variation against HVL for kV = 28, d=4 cm and g= 0.6 are also presented. The results of this code are in good agreement with those previously reported in the literature. Conclusion: The code developed in this study calculates the glandular dose quickly, and it is complete and

  15. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients

    International Nuclear Information System (INIS)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-01-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  16. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients; Dosis glandular en examenes de tomosintesis de mama: estudio preliminar con una muestra de pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-07-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  17. Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging

    International Nuclear Information System (INIS)

    Thacker, Samta C; Glick, Stephen J

    2004-01-01

    The development of new digital mammography techniques such as dual-energy imaging, tomosynthesis and CT breast imaging will require investigation of optimal camera design parameters and optimal imaging acquisition parameters. In optimizing these acquisition protocols and imaging systems it is important to have knowledge of the radiation dose to the breast. This study presents a methodology for estimating the normalized glandular dose to the uncompressed breast using the geometry proposed for flat-panel CT breast imaging. The simulation uses the GEANT 3 Monte Carlo code to model x-ray transport and absorption within the breast phantom. The Monte Carlo software was validated for breast dosimetry by comparing results of the normalized glandular dose (DgN) values of the compressed breast to those reported in the literature. The normalized glandular dose was then estimated for a range of breast diameters from 10 cm to 18 cm using an uncompressed breast model with a homogeneous composition of adipose and glandular tissue, and for monoenergetic x-rays from 10 keV to 120 keV. These data were fit providing expressions for the normalized glandular dose. Using these expressions for the DgN coefficients and input variables such as the diameter, height and composition of the breast phantom, the mean glandular dose for any spectra can be estimated. A computer program to provide normalized glandular dose values has been made available online. In addition, figures displaying energy deposition maps are presented to better understand the spatial distribution of dose in CT breast imaging

  18. Computation of the glandular radiation dose in digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Suryanarayanan, Sankararaman; Vedantham, Srinivasan; D'Orsi, Carl; Karellas, Andrew

    2007-01-01

    Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (D g N) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the D g N to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammographic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided

  19. Evaluation of average glandular dose in mammography services in 10 cities of Colombia; Avaliacao de dose glandular media em servicos de mamografia de 10 cidades de Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D. [Grupo de Prevencion Temprana Del Cancer, Instituto Nacional de Cancerologia, Bogota D.C. (Colombia)

    2016-07-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  20. Breast dose in mammography is about 30% lower when realistic heterogeneous glandular distributions are considered

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Andrew M., E-mail: amhern@ucdavis.edu [Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States); Seibert, J. Anthony; Boone, John M. [Departments of Radiology and Biomedical Engineering, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States)

    2015-11-15

    Purpose: Current dosimetry methods in mammography assume that the breast is comprised of a homogeneous mixture of glandular and adipose tissues. Three-dimensional (3D) dedicated breast CT (bCT) data sets were used previously to assess the complex anatomical structure within the breast, characterizing the statistical distribution of glandular tissue in the breast. The purpose of this work was to investigate the effect of bCT-derived heterogeneous glandular distributions on dosimetry in mammography. Methods: bCT-derived breast diameters, volumes, and 3D fibroglandular distributions were used to design realistic compressed breast models comprised of heterogeneous distributions of glandular tissue. The bCT-derived glandular distributions were fit to biGaussian functions and used as probability density maps to assign the density distributions within compressed breast models. The MCNPX 2.6.0 Monte Carlo code was used to estimate monoenergetic normalized mean glandular dose “DgN(E)” values in mammography geometry. The DgN(E) values were then weighted by typical mammography x-ray spectra to determine polyenergetic DgN (pDgN) coefficients for heterogeneous (pDgN{sub hetero}) and homogeneous (pDgN{sub homo}) cases. The dependence of estimated pDgN values on phantom size, volumetric glandular fraction (VGF), x-ray technique factors, and location of the heterogeneous glandular distributions was investigated. Results: The pDgN{sub hetero} coefficients were on average 35.3% (SD, 4.1) and 24.2% (SD, 3.0) lower than the pDgN{sub homo} coefficients for the Mo–Mo and W–Rh x-ray spectra, respectively, across all phantom sizes and VGFs when the glandular distributions were centered within the breast phantom in the coronal plane. At constant breast size, increasing VGF from 7.3% to 19.1% lead to a reduction in pDgN{sub hetero} relative to pDgN{sub homo} of 23.6%–27.4% for a W–Rh spectrum. Displacement of the glandular distribution, at a distance equal to 10% of the

  1. Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter

    International Nuclear Information System (INIS)

    Lee, In Ja

    2009-01-01

    The study examined the relationship between the compressed breast thickness and Average Glandular Dose (AGD) among 1,969 outpatients who went through breast X-ray in a university hospital for 10 months from July 1st, 2007 to April 30th, 2008. Then it analyzed the result acquired from 3,900 cases of Cranio-Caudal (CC) view, especially, when the breasts were compressed (13-15daN). The following is the conclusion driven from the relationship analysis. 1. The subjects aged in 40s and 50s were 2,679 out of 3,900 cases and this figure was 68.69% in all. 2. In terms of distribution depending on focus/filter, 41.0% was Mo/Mo, 34.8% was Mo/Rh, and 24.2% was Rh/Rh. 3. In terms of compressed breast thickness depending on focus/filter, the average thickness was 26.91 mm at Mo/Mo, 38.84 mm at Mo/Rh, and 48.80 mm at Rh/Rh. The average thickness of the entire cases was shown to be 36.27 mm. 4. AGD depending on focus/filter was 1.27 mGy at Mo/Mo, 1.55 mGy at Mo/Rh, and 1.42 mGy at Rh/Rh. The average glandular dose of the entire cases was shown to be 1.43 mGy. 5. The relationship of AGD depending on compressed breast thickness at Mo/Mo was y=0.0318x + 0.470 while it was y=0.0206x + 0.709 at Mo/Rh and y=0.0248x + 0.335 at Mo/Rh. It was highly influenced by the compressed breast thickness, however, more variation was detected at Mo/Mo depending on breast thickness.

  2. Investigation of mean glandular dose versus compressed breast thickness relationship for mammography

    International Nuclear Information System (INIS)

    Bor, D.; Tukel, S.; Olgar, T.; Toklu, T.; Aydin, E.; Akyol, O.

    2008-01-01

    The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The high data scattering from the best fit reduces the reliability of this technique. The aim of this study was to investigate the accuracy of this relationship using the data collected from a patient survey and phantom experiment. Patients were divided into three different groups according to their breast glandularities, which were predicted from the inspection of previous mammograms. X-ray beam qualities that will be used in patient examinations were determined according to breast thickness and predicted glandularities. The MGD versus CBT relationship for all the examined patients resulted in a poor correlation (R 2 = 0.28). This relationship was separately obtained for each glandularity group and also for sub-groups of specific beam qualities. The best correlation (R 2 = 0.73) was obtained for the fatty breast group and Mo/Mo combination. A low correlation (R 2 = 0.34) was observed in the mid-glandularity group due to inclusion of a wide range of glandularities in this group. In the case of the dense breast group, although the glandularity range was narrow, there were e still high data scattering (R 2 = 0.25). This was probably due to the use of Mo/Rh and Mo/Mo combinations. This is validated by obtaining the MGD-CBT relationship specific to Mo/Mo combination (R 2 = 0.61). (authors)

  3. Evaluation of subject contrast and normalized average glandular dose by semi-analytical models

    International Nuclear Information System (INIS)

    Tomal, A.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    In this work, two semi-analytical models are described to evaluate the subject contrast of nodules and the normalized average glandular dose in mammography. Both models were used to study the influence of some parameters, such as breast characteristics (thickness and composition) and incident spectra (kVp and target-filter combination) on the subject contrast of a nodule and on the normalized average glandular dose. From the subject contrast results, detection limits of nodules were also determined. Our results are in good agreement with those reported by other authors, who had used Monte Carlo simulation, showing the robustness of our semi-analytical method.

  4. Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data

    NARCIS (Netherlands)

    Bouwman, R. W.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Schopphoven, S.; Jeukens, C. R. L. P. N.; Veldkamp, W. J. H.; Dance, D. R.

    2015-01-01

    For the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT) phantoms simulating standard model breasts are used. These phantoms consist of slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE). In the last

  5. Glandular dose and image quality control in mammography facilities with computerized radiography systems

    International Nuclear Information System (INIS)

    Dantas, Marcelino Vicente de Almeida

    2010-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  6. Method for the evaluation of a average glandular dose in mammography

    International Nuclear Information System (INIS)

    Okunade, Akintunde Akangbe

    2006-01-01

    This paper concerns a method for accurate evaluation of average glandular dose (AGD) in mammography. At different energies, the interactions of photons with tissue are not uniform. Thus, optimal accuracy in the estimation of AGD is achievable when the evaluation is carried out using the normalized glandular dose values, g(x,E), that are determined for each (monoenergetic) x-ray photon energy, E, compressed breast thickness (CBT), x, breast glandular composition, and data on photon energy distribution of the exact x-ray beam used in breast imaging. A generalized model for the values of g(x,E) that is for any arbitrary CBT ranging from 2 to 9 cm (with values that are not whole numbers inclusive, say, 4.2 cm) was developed. Along with other dosimetry formulations, this was integrated into a computer software program, GDOSE.FOR, that was developed for the evaluation of AGD received from any x-ray tube/equipment (irrespective of target-filter combination) of up to 50 kVp. Results are presented which show that the implementation of GDOSE.FOR yields values of normalized glandular dose that are in good agreement with values obtained from methodologies reported earlier in the literature. With the availability of a portable device for real-time acquisition of spectra, the model and computer software reported in this work provide for the routine evaluation of AGD received by a specific woman of known age and CBT

  7. Evaluation of average glandular dose in mammography services in 10 cities of Colombia

    International Nuclear Information System (INIS)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D.

    2016-01-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  8. Assessment of mean glandular dose to patients from digital mammography systems

    International Nuclear Information System (INIS)

    Pwamang, Caroline K.

    2016-07-01

    Mean glandular dose assessment of patients undergoing digital mammography examination has been done. A total of 297 patient data was used for the study. Basic Quality Control tests were done to ascertain the performance of the equipment used. The results of Quality Control tests indicated that the three Mammography units used for this study were functioning within the internationally acceptable performance criteria. Patients with a breast thickness of 30 mm within the two age groups of 40-49 yrs and 50-64 yrs received doses slightly higher than the acceptable dose levels. A patient in the category 40-49 yrs with breast thickness of 30 mm received 1.83 mGy as calculated Mean Glandular Dose, 2.10 mGy was the recorded dose and 1.58 mGy was recorded under the age group 50-64 yrs. These values have deviated by -22%, -40%, and -5.33% respectively from 1.5 mGy which is the recommended dose for a breast thickness of 30 mm. Also patients with breast thickness of 70 mm under the age group 40–49 yrs had a recorded dose of 6.58 mGy, which deviated by -1.21% from the recommended value of 6.5 mGy for that breast thickness. Aside these values, all the other values were within the recommended dose values. The percentage deviation between the recommended values and the calculated values was within ±25% which was a working limit that was set for this work. Doses delivered by the Full-field Digital mammography equipment were higher than doses delivered by the Computered Radiography equipment. The calculated Mean Glandular Doses for the three facilities were within recommended dose values. (author)

  9. The effect of aluminium added filter on mean glandular dose using mammography machine in MINT Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Abd Aziz Mhd Ramli

    2005-01-01

    The effect of various thickness of aluminium added filter on mean glandular dose in mammography is investigated for a standard breast phantom, 4.2 cm Perspex. A mammography machine in Medical Physics Laboratory MINT, Bennett Model DMF-150 is used to provide radiation in various kV range under clinical condition. The mean glandular dose on the phantom were measured based on technique recommended by AAPM protocol (1990) report no 29. The mean glandular dose was found reducing with increasing thickness of added filter. A more detail results of this study is presented in this paper. (Author)

  10. Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system

    International Nuclear Information System (INIS)

    Rodrigues, Leonardo; Braz, Delson; Goncalves Magalhaes, Luis Alexandre

    2015-01-01

    Digital breast tomosynthesis (DBT) is a screening and diagnostic modality that acquires images of the breast at multiple angles during a short scan. The Selenia Dimensions (Hologic, Bedford, Mass) DBT system can perform both full-field digital mammography and DBT. The system acquires 15 projections over a 15 deg. angular range (from -7.5 deg. to +7.5 deg.). An important factor in determining the optimal imaging technique for breast tomosynthesis is the radiation dose. In breast imaging, the radiation dose of concern is that deposited in the glandular tissue of the breast because this is the tissue that has a risk of developing cancer. The concept of the normalised mean glandular dose (DgN) has been introduced as the metric for the dose in breast imaging. The DgN is difficult to measure. The Monte Carlo techniques offer an alternative method for a realistic estimation of the radiation dose. The purpose of this work was to use the Monte Carlo code MCNPX technique to generate monoenergetic glandular dose data for estimating the breast tissue dose in tomosynthesis for arbitrary spectra as well as to observe the deposited radiation dose by projection on the glandular portion of the breast in a Selenia Dimensions DBT system. A Monte Carlo simulation of the system was developed to compute the DgN in a craniocaudal view. Monoenergetic X-ray beams from 10 to 49 keV in 1-keV increments were used. The simulation utilised the assumption of a homogeneous breast composition and three compositions (0 % glandular, 50 % glandular and 100 % glandular). The glandular and adipose tissue compositions were specified according ICRU Report 44. A skin layer of 4 mm was assumed to encapsulate the breast on all surfaces. The breast size was varied using the chest wall-to-nipple distance (CND) and compressed breast thickness (t). In this work, the authors assumed a CND of 5 cm and the thicknesses ranged from 2 to 8 cm, in steps of 2 cm. The fractional energy absorption increases (up to 44

  11. Average glandular dose in routine mammography screening using a Sectra Microdose Mammography unit

    International Nuclear Information System (INIS)

    Hemdal, B.; Herrnsdorf, L.; Andersson, I.; Bengtsson, G.; Heddson, B.; Olsson, M.

    2005-01-01

    The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional system can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospitals of Helsingborg (Sweden)). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated than non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurement were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction. (authors)

  12. Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

    Directory of Open Access Journals (Sweden)

    Ali Asghar Mowlavi

    2011-03-01

    Full Text Available Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRAN code to calculate average glandular dose. Results: Average glandular dose variation was calculated against the voltage of the mammographic x-ray tube for d = 5 cm, HVL= 0.35 mm Al, and different value of g. Also, the results related to average glandular absorbed dose variation per unit roentgen radiation against the glandular fraction of breast tissue for kV = 28 and HVL = 0.400 mmAl and different values of d are presented. Finally, average glandular dose against d for g = 60% and three values of kV (23, 27, 35 kV with corresponding HVLs have been calculated. Discussion and Conclusion: The absorbed dose computational program is accurate, complete, fast and user friendly. This program can be used for optimization of exposure dose in mammography. Also, the results of this research are in good agreement with the computational results of others.

  13. Impact of digitalization of mammographic units on average glandular doses in the Flemish Breast Cancer Screening Program

    OpenAIRE

    De Hauwere, An; Thierens, Hubert

    2012-01-01

    The impact of digitalization on the average glandular doses in 49 mammographic units participating in the Flemish Breast Cancer Screening Program was studied. Screen-film was changed to direct digital radiography and computed radiography in 25 and 24 departments respectively. Average glandular doses were calculated before and after digitalization for different PMMA-phantom thicknesses and for groups of 50 successive patients. For the transition from screen-film to computed radiography both ph...

  14. Estimation of the average glandular dose on a team of tomosynthesis

    International Nuclear Information System (INIS)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-01-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  15. Estimate of average glandular dose (AGD) in national clinics of mammography

    International Nuclear Information System (INIS)

    Mora, Patricia; Segura, Helena

    2004-01-01

    The breast cancer represents the second cause of death by cancer in the femme population of our country. The specialized equipment for the obtaining of the mammographic images is higher every day and its use increases daily. The quality of the radiographic study is linked to the dose that this tissue intrinsically sensible receives to the ionizing radiations. The present work makes the first national study to quantify the average glandular doses and to connect them with the diagnostic quality and the recommendations to international scale. (Author) [es

  16. Effect of the glandular composition on digital breast tomosynthesis image quality and dose optimisation

    International Nuclear Information System (INIS)

    Marques, T.; Di Maria, S.; Vaz, P.; Ribeiro, A.; Belchior, A.; Cardoso, J.; Matela, N.; Oliveira, N.; Almeida, P.; Janeiro, L.

    2015-01-01

    In the image quality assessment for digital breast tomosynthesis (DBT), a breast phantom with an average percentage of 50 % glandular tissue is seldom used, which may not be representative of the breast tissue composition of the women undergoing such examination. This work aims at studying the effect of the glandular composition of the breast on the image quality taking into consideration different sizes of lesions. Monte Carlo simulations were performed using the state-of-the-art computer program PENELOPE to validate the image acquisition system of the DBT equipment as well as to calculate the mean glandular dose for each projection image and for different breast compositions. The integrated PENELOPE imaging tool (PenEasy) was used to calculate, in mammography, for each clinical detection task the X-ray energy that maximises the figure of merit. All the 2D cranial-caudal projections for DBT were simulated and then underwent the reconstruction process applying the Simultaneous Algebraic Reconstruction Technique. Finally, through signal-to-noise ratio analysis, the image quality in DBT was assessed. (authors)

  17. Estimation of the average glandular dose on a team of tomosynthesis; Estimacion de la dosis glandular media en un equipo de tomosintesis

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-07-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  18. Papel dos tricomas glandulares da folha do tomateiro na oviposição de Tuta absoluta Role of tomato leaf glandular trichomes on oviposition of Tuta absoluta

    Directory of Open Access Journals (Sweden)

    Elsa Gilardón

    2001-03-01

    Full Text Available Os tricomas glandulares presentes nas folhas e ramos das plantas do gênero Lycopersicon são responsáveis pela secreção de metabólitos de diferentes naturezas. A presença de alguns desses compostos tem sido associada à resistência do tomate a diferentes insetos. A traça-do-tomateiro, Tuta absoluta (Meyrick, é uma das pragas mais nocivas da América do Sul. O adulto oviposita sobre as folhas do tomate e suas larvas abrem galerias no mesófilo das folhas, ramos, flores e frutos. As espécies silvestres do tomate conservam a capacidade de biossintetizar compostos químicos que lhes conferem resistência a esta praga. No presente trabalho, foi avaliada a preferência para oviposição desse inseto sobre folhas com e sem tricomas glandulares de L. esculentum (Mill. cv. Uco Plata, suscetível, e de L. hirsutum f. glabratum (Mull. PI 134417, espécie silvestre afim ao tomate, e resistente à traça. Os resultados sugerem que as fêmeas ovipositam indistintamente sobre as folhas de ambas espécies, independentemente da presença, ou não, dos tricomas glandulares. E a presença destes e de seus exsudatos não têm efeito inibidor na oviposição do inseto.In the genus Lycopersicon, different metabolites are secreted by the glandular trichomes of leaves and stems. These compounds have been associated to different tomato pests resistance. The South American tomato pinworm, Tuta absoluta (Meyrick, is one of the most harmful pests in South America. The females oviposit on tomato leaves and the larvae mine the leaf mesophyl, stems, flowers and fruits. Some wild accessions of Lycopersicon keep their capacity to synthesize allelochemicals that protect them from the pest. In this paper a comparison was made between the tomato pinworm oviposition on leaves with and without trichomes of L. esculentum (Mill. cv. Uco Plata, a susceptible cultivar, and L. hirsutum f. glabratum (Mull. PI 134417, a resistant wild accession. Results suggest that the female

  19. Evaluation of average glandular dose in digital and conventional systems of the mammography

    International Nuclear Information System (INIS)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J.

    2014-01-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  20. A study on the image quality of mammography and the average glandular dose

    International Nuclear Information System (INIS)

    Lee, In Ja; Kim, Hak Sung; Kim, Sung Soo; Huh, Joon

    2002-01-01

    We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospital in Seoul. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospital. The unit at the B hospital exceeded the allowable limit by ± 0.15. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. The image quality of breast phantom photography was affected by the screen/film system among the hospital. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured 0.26 ∼ 1.39 mGy less than ACR standard 3.0 mGy

  1. Preliminary results of the average glandular dose to the breast with TLDS measure is computed as the conversion factors

    International Nuclear Information System (INIS)

    Sardo, Luiz T.L.; Almeida, Claudio D.; Coutinho, Celia M.C.

    2013-01-01

    At mammography exams there is a risk of a breast cancer induced from the absorbed dose by the glandular tissue. According to the National Institute of Cancer, INCA, breast cancer is the second type most frequent in the world and the most common among women, therefore the necessity of monitoring the mean glandular dose, D G . Measuring methods of D G were established by some authors. Among the established methods the method of Dance is one of the most known. In this study was utilized a measurement method realized with TL dosimeters inserted in a breast tissue equivalent phantom, BTE, with 46% of glandularity and exposed using Mo/Mo and Mo/Rh target/filter combination and 28kV. To ensure this measurement method the results were compared with a calculation method, used by Dance, of D G from the measurement of incident air kerma, K i , and conversion factors to consider mainly the beam quality, the compressed thickness and the glandularity of the breast. The results of the comparison of the D G measurement with the obtained dose by the method of Dance demonstrated that for the thickness of 4.0 and 6.0 cm the doses were consistent. For the thickness of 5.0 cm the difference was higher, indicating that the glandularity may influence, suggesting further investigation. (author)

  2. Mean glandular dose measurement on various breast phantom using mammography machine in MINT Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Asmaliza Hashim; Abd Aziz Mhd Ramli

    2005-01-01

    Until recently, mammography have been the primary means of detecting early breast cancer. Although there is a risk of radiation- induced carcinogenesis associated with the x-ray examination of the female breast, but this risk is small compared to its benefits with modern equipment and technique. Therefore, it is important to determine the dose of the tissue at risk from radiation exposure by measuring the mean glandular dose (MGD). This can help minimize the risk to the patient. This paper describe the MGD measurement done on various types and thickness of breast phantom using a Bennett mammography machine model DMF-150 in the Medical Physics laboratory at the Malaysian Institute for Nuclear Technology Research (MINT). Results of this study are discussed in this paper. (Author)

  3. Determination of mean glandular dose on patients and phantom in X-ray mammography

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Vassileva, J.

    2008-01-01

    The statistics of breast cancer rate in Bulgaria show a tendency towards increase of the morbidity from this disease. Last years campaigns against breast cancer are organized yearly. This leads to an increased number of screening and diagnostic mammograms that are made in the country. The dose associated with the examination is very low but not slightingly small. The glandular tissue in the breast is considered to be the most sensitive in relation to the radiation exposure. Several publications propose different methods, measurement set up or conversion coefficients for the calculation of the mean glandular dose (MGD) delivered to the breast during the X-ray examination. The question about the standardization of the measurement procedures arises since the differences in the results obtained using different methodologies may be quite big. The aim of this work is to develop a standard procedure for the measurement of MGD based on the recommendations mentioned in the European protocol on dosimetry in mammography, the European protocol for the quality control of the physical and technical aspects of mammography screening and the Code of practice: TRS 457 of the IAEA. Five contemporary film-screen mammography units were included in this study. Attention should be paid to the measurement set up. The reference point is chosen 6 cm from the chest wall edge laterally centered. If an ionization chamber is used for dose measurements the compression plate should be placed in close contact with it. If solid state detectors are used the compression plate should be put away from the detector and the output recalculated like if the plate is near the detector. The conversion coefficients for age dependence are not used in this study as not appropriate for the population included in it. PMMA measurements for the determination of diagnostic reference levels could be used but more correct results would be obtained with patient measurements

  4. Evaluation of mean glandular dose in a full-field digital mammography unit in Tabriz (IR)

    International Nuclear Information System (INIS)

    Riabi, H. A.; Mehnati, P.; Mesbahi, A.

    2010-01-01

    This study was aimed at evaluating the mean glandular dose (MGD) and affecting factors during mammography examinations by a full-field digital mammography unit. An extensive quality control program was performed to assure that the unit is properly working. Required information including compressed breast thickness (CBT), breast parenchymal pattern and technical factors used for imaging were recorded. An entrance skin exposure measurement was also performed using slabs of polymethylmethacrylate with 2-8 cm thickness. On the basis of recorded information and measured data, the MGD was estimated for 1145 mammography examinations obtained from 298 patients. Mean CBTs of 4.9 and 5.8 cm and MGDs of 2 and 2.4 mGy were observed for cranio-caudal and medio-lateral oblique views, respectively. Significant correlation was seen between MGD and CBT, breast parenchymal pattern and applied kVp and mAs. (authors)

  5. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    Science.gov (United States)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  6. Assessment of mean glandular dose for patients in mammography in some Hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Abu Elmola, Alaa Mahdi

    2016-12-01

    A mammography examination facilitates the early detection of breast cancer. However, the potential risk of radiation- induced carcinogenesis is also increased with such a procedure. Thus assessment of the breast dose is important. The objective of this study was to determine the mean glandular dose (MGD) resulting from cranio caudal(CC) and mediolateral oblique (MLO) views in one breast and the total dose per woman in Sudan, and to identify the factors affecting it. Measurements were performed to estimate mean glandular doses for 60 patients who underwent mammography examination in two clinics in Khartoum, Sudan.Doses were studied in RCH and NDC, centers which were using computed radiography(CR)devices. The piranha system was used for determining the MGD in this work. The characteristics of the radiographic equipment and the exposure data of each patient were recorded using designed format. The MGD was calculated from the measured incident Air kerma using appropriate conversion coefficients. The range of CBT was (1-7)cm for two projections. The respective averages for the CC and MLO projections were (4.55±1.38)mGy and (4.15±1.33) mGy, respectively. The average MGD per image was (4.3±1.35)mGy. The MGD per women was (8.6±1.35)mGy. The mean±SD MGD per image in the present study was lower than most of similar reports. The average MGD values recorded in this study were above the limiting value of the Institute of Physical Sciences in Medicine(2.0 mGy) and American College of Radiology (3.0 mGy recommendation. This suggests that mammography x-ray generators in this case are not capable of achieving acceptable dose levels for patients safety. Therefore, with consideration of all other factors, quality control program tests must be carried out periodically and frequently of the mammography equipment.(Author)

  7. Estimation of average glandular dose depending on the thickness of the breast

    International Nuclear Information System (INIS)

    Real, Jessica V.; Luz, Renata M. da; Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da

    2014-01-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient

  8. A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

    Science.gov (United States)

    Sarno, Antonio; Dance, David R; van Engen, Ruben E; Young, Kenneth C; Russo, Paolo; Di Lillo, Francesca; Mettivier, Giovanni; Bliznakova, Kristina; Fei, Baowei; Sechopoulos, Ioannis

    2017-07-01

    To characterize the dependence of normalized glandular dose (DgN) on various breast model and image acquisition parameters during spot compression mammography and other partial breast irradiation conditions, and evaluate alternative previously proposed dose-related metrics for this breast imaging modality. Using Monte Carlo simulations with both simple homogeneous breast models and patient-specific breasts, three different dose-related metrics for spot compression mammography were compared: the standard DgN, the normalized glandular dose to only the directly irradiated portion of the breast (DgNv), and the DgN obtained by the product of the DgN for full field irradiation and the ratio of the mid-height area of the irradiated breast to the entire breast area (DgN M ). How these metrics vary with field-of-view size, spot area thickness, x-ray energy, spot area and position, breast shape and size, and system geometry was characterized for the simple breast model and a comparison of the simple model results to those with patient-specific breasts was also performed. The DgN in spot compression mammography can vary considerably with breast area. However, the difference in breast thickness between the spot compressed area and the uncompressed area does not introduce a variation in DgN. As long as the spot compressed area is completely within the breast area and only the compressed breast portion is directly irradiated, its position and size does not introduce a variation in DgN for the homogeneous breast model. As expected, DgN is lower than DgNv for all partial breast irradiation areas, especially when considering spot compression areas within the clinically used range. DgN M underestimates DgN by 6.7% for a W/Rh spectrum at 28 kVp and for a 9 × 9 cm 2 compression paddle. As part of the development of a new breast dosimetry model, a task undertaken by the American Association of Physicists in Medicine and the European Federation of Organizations of Medical Physics

  9. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.

    Science.gov (United States)

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-10-01

    X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

  10. Comparison of anode/filter combinations in digital mammography with respect to the average glandular dose

    International Nuclear Information System (INIS)

    Uhlenbrock, D.F.; Mertelmeier, Thomas

    2009-01-01

    To investigate the average glandular dose (AGD) applied for clinical digital mammograms acquired with the anode/filter combinations molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh), and tungsten/rhodium (W/Rh). Using the method of Dance, the AGD was evaluated from the exposure data of 4867 digital mammograms at two sites equipped with a full-field digital mammography (FFDM) system based on an amorphous selenium detector. 1793 images were acquired and analyzed with Mo/Mo, 643 with Mo/Rh, and 2431 with W/Rh. In the Mo/Mo cases the mean compressed breast thickness was 46 ± 10 mm with an average AGD of 2.29 ± 1.31 mGy. For the Mo/Rh cases with a mean compressed thickness of 64 ± 9 mm, we obtained 2.76 ± 1.31 mGy. The W/Rh cases with a mean compressed thickness of 52 ± 13 mm resulted in 1.26 ± 0.44 mGy. The image quality was assessed as normal and adequate for diagnostic purposes in all cases. (orig.)

  11. Higher glandular trichome density in tomato leaflets and repellence to spider mites Alta densidade de tricomas glandulares em tomateiro e aumento da repelência a ácaros rajados

    Directory of Open Access Journals (Sweden)

    Wilson Roberto Maluf

    2007-09-01

    Full Text Available The objective of this work was to evaluate the feasibility of selection for higher glandular trichome densities, as an indirect criterion of selection for increasing repellence to spider mites Tetranychus urticae, in tomato populations derived from an interspecific cross between Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Trichome densities were evaluated in 19 genotypes, including 12 from advanced backcross populations, derived from the original cross L. esculentum x L. hirsutum var. glabratum PI 134417. Counts were made both on the adaxial and abaxial leaf surfaces, and trichomes were classified into glandular types IV and VI, other glandular types (types I+VII, and nonglandular types. Mite repellence was measured by distances walked by mites onto the tomato leaf surface after 20, 40 and 60 min. Spider mite repellence biotests indicated that higher densities of glandular trichomes (especially type VI decreased the distances walked by the mites onto the tomato leaf surface. Selection of plants with higher densities of glandular trichomes can be an efficient criterion to obtain tomato genotypes with higher resistance (repellence to spider mites.O objetivo deste trabalho foi avaliar a eficiência da seleção para maior densidade de tricomas glandulares na resistência (repelência ao ácaro Tetranychus urticae, em populações de tomate derivadas do cruzamento interespecífico Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Foram avaliados 19 genótipos quanto à densidade de tricomas, que incluíram 12 derivados de populações avançadas de retrocruzamentos, obtidos a partir do cruzamento original L. esculentum x L. hirsutum var. glabratum PI 134417. Nas faces abaxial e adaxial dos folíolos, realizaram-se as contagens e os tricomas foram classificados em glandulares tipo IV e VI, outros glandulares (tipo I e VII e não glandulares. A repelência aos ácaros foi medida pela distância média, percorrida pelo

  12. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  13. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    Science.gov (United States)

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  14. Validation of mean glandular dose values provided by a digital breast tomosynthesis system in Brazil

    International Nuclear Information System (INIS)

    Beraldo O, B.; Paixao, L.; Donato da S, S.; Araujo T, M. H.; Nogueira, M. S.

    2014-08-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality that provides quasi-three-dimensional structural information of the breast and has strong promise to improve the differentiation of normal tissue and suspicious masses reducing the tissue overlaps. DBT images are reconstructed from a sequence of low-dose X-ray projections of the breast acquired at a small number of angles over a limited angular range. The Ho logic Selen ia Dimensions system is equipped with an amorphous Selenium (a-Se) detector layer of 250 μm thickness and a 70 μm pixel pitch. Studies are needed to determine the radiation dose of patients that are undergoing this emerging procedure to compare with the results obtained in DBT images. The mean glandular dose (D G ) is the dosimetric quantity used in quality control of the mammographic systems. The aim of this work is to validate D G values for different breast thicknesses provided by a Ho logic Selen ia Dimensions system using a DBT mode in comparison with the same results obtained by a calibrated 90 X 5-6M-model Radcal ionization chamber. D G values were derived from the incident air kerma (K i ) measurements and tabulated conversion coefficients that are dependent on the half value layer (HVL) of the X-ray spectrum. Voltage and tube loading values were recorded in irradiations using W/Al anode/filter combination, automatic exposure control mode and polymethyl methacrylate (PMMA) slabs which simulate different breast thicknesses. For K i measurements, the ionization chamber was positioned at 655 mm from the focus and the same radiographic technique values were selected with the manual mode. D G values for a complete procedure ranged from 0.9 ± 0.1 to 3.7 ± 0.4 mGy. The results for different breast thicknesses are in accordance with values obtained by DBT images and with acceptable levels established by the Commission of the European Communities (Cec) and the International Atomic Energy Agency (IAEA). This work contributes to

  15. Validation of mean glandular dose values provided by a digital breast tomosynthesis system in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Beraldo O, B.; Paixao, L.; Donato da S, S. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Post-graduation in Sciences and Technology of Radiations Minerals and Materials, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil); Araujo T, M. H. [Dr Maria Helena Araujo Teixeira Clinic, Guajajaras 40, 30180-100 Belo Horizonte (Brazil); Nogueira, M. S., E-mail: bbo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil)

    2014-08-15

    Digital breast tomosynthesis (DBT) is an emerging imaging modality that provides quasi-three-dimensional structural information of the breast and has strong promise to improve the differentiation of normal tissue and suspicious masses reducing the tissue overlaps. DBT images are reconstructed from a sequence of low-dose X-ray projections of the breast acquired at a small number of angles over a limited angular range. The Ho logic Selen ia Dimensions system is equipped with an amorphous Selenium (a-Se) detector layer of 250 μm thickness and a 70 μm pixel pitch. Studies are needed to determine the radiation dose of patients that are undergoing this emerging procedure to compare with the results obtained in DBT images. The mean glandular dose (D{sub G}) is the dosimetric quantity used in quality control of the mammographic systems. The aim of this work is to validate D{sub G} values for different breast thicknesses provided by a Ho logic Selen ia Dimensions system using a DBT mode in comparison with the same results obtained by a calibrated 90 X 5-6M-model Radcal ionization chamber. D{sub G} values were derived from the incident air kerma (K{sub i}) measurements and tabulated conversion coefficients that are dependent on the half value layer (HVL) of the X-ray spectrum. Voltage and tube loading values were recorded in irradiations using W/Al anode/filter combination, automatic exposure control mode and polymethyl methacrylate (PMMA) slabs which simulate different breast thicknesses. For K{sub i} measurements, the ionization chamber was positioned at 655 mm from the focus and the same radiographic technique values were selected with the manual mode. D{sub G} values for a complete procedure ranged from 0.9 ± 0.1 to 3.7 ± 0.4 mGy. The results for different breast thicknesses are in accordance with values obtained by DBT images and with acceptable levels established by the Commission of the European Communities (Cec) and the International Atomic Energy Agency (IAEA

  16. Comparison of average glandular dose in screen-film and digital mammography using breast tissue-equivalent phantom

    International Nuclear Information System (INIS)

    Shin, Gwi Soon; Kim, Jung Min; Kim, You Hyun; Choi, Jong Hak; Kim, Chang Kyun

    2007-01-01

    In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate (IP). We measured average glandular doses (ADG) in screen-film mammography (SFM) system with slow screen-film combination, computed mammography (CM) system, indirect digital mammography (IDM) system and direct digital mammography (DDM) system using breast tissue-equivalent phantom (glandularity 30%, 50% and 70%). The results were shown as follows: AGD values for DDM system were highest than those for other systems. Although automatic exposure control (AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter (Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in order to estimate a patient radiation dose

  17. Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data

    International Nuclear Information System (INIS)

    Bouwman, R W; Van Engen, R E; Den Heeten, G J; Broeders, M J M; Veldkamp, W J H; Young, K C; Dance, D R; Schopphoven, S; Jeukens, C R L P N

    2015-01-01

    For the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT) phantoms simulating standard model breasts are used. These phantoms consist of slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE). In the last decades the automatic exposure control (AEC) increased in complexity and became more sensitive to (local) differences in breast composition. The question is how well the AGD estimated using these simple dosimetry phantoms agrees with the average patient AGD. In this study the AGDs for both dosimetry phantoms and for patients have been evaluated for 5 different x-ray systems in DM and DBT modes. It was found that the ratios between patient and phantom AGD did not differ considerably using both dosimetry phantoms. These ratios averaged over all breast thicknesses were 1.14 and 1.15 for the PMMA and PMMA-PE dosimetry phantoms respectively in DM mode and 1.00 and 1.02 in the DBT mode. These ratios were deemed to be sufficiently close to unity to be suitable for dosimetry evaluation in quality control procedures. However care should be taken when comparing systems for DM and DBT since depending on the AEC operation, ratios for particular breast thicknesses may differ substantially (0.83–1.96). Although the predictions of both phantoms are similar we advise the use of PMMA  +  PE slabs for both DM and DBT to harmonize dosimetry protocols and avoid any potential issues with the use of spacers with the PMMA phantoms. (paper)

  18. Image quality, threshold contrast and mean glandular dose in CR mammography

    International Nuclear Information System (INIS)

    Jakubiak, R R; Gamba, H R; Neves, E B; Peixoto, J E

    2013-01-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both

  19. Papel da 2-tridecanona e dos tricomas glandulares tipo VI na resistência do tomateiro a Tuta absoluta Role of 2-tridecanone and type VI glandular trichome on tomato resistance to Tuta absoluta

    Directory of Open Access Journals (Sweden)

    Elsa Gilardón

    2001-07-01

    Full Text Available O metabólito secundário 2-tridecanona, secretado pelos tricomas glandulares tipo VI das folhas de tomateiro silvestre, Lycopersicon hirsutum L., confere-lhe resistência a uma grande variedade de insetos, inclusive a traça-do-tomateiro, Tuta absoluta (Meyrick. O objetivo do trabalho foi avaliar a concentração de 2- tridecanona, a densidade de tricomas glandulares tipo VI e o grau de infestação da traça-do-tomateiro na cultivar suscetível 'Uco Plata' (Lycopersicon esculentum Mill., na linhagem resistente PI 134417 (L. hirsutum f. glabratum e em suas progênies F1 e F2. Foram avaliadas ainda as possíveis associações entre a concentração de 2-tridecanona, a densidade de tricomas glandulares tipo VI e o grau de infestação da traça-do-tomateiro. O grau médio de infestação da traça-do-tomateiro em 'Uco Plata' foi significativamente superior ao obtido em PI 134417. Ainda que a concentração de 2-tridecanona tenha sido significativamente superior no parental resistente, a presença deste metabólito somente explicaria parcialmente a resistência (R² = 8,17%. Não se detectaram diferenças significativas na densidade de tricomas tipo VI entre o parental suscetível e o resistente. Este comportamento ocorreu independentemente do conteúdo de 2-tridecanona e do grau de infestação da traça-do-tomateiro.The secondary metabolite 2-tridecanone, secreted by the type VI glandular trichomes present in the leaves of Lycopersicon hirsutum L., make it resistant to a great variety of insects, including the tomato pinworm, Tuta absoluta (Meyrick. The 2-tridecanone concentration, the type VI glandular trichome densities and the pinworm infestation degree were evaluated on the Lycopersicon esculentum Mill. susceptible cultivar 'Uco Plata', on the Lycopersicon hirsutum f. glabratum resistant accession PI 134417 and on their F1 and F2. The mean infestation degree with pinworm larvae was significantly higher in 'Uco Plata' than in PI 134417. The 2

  20. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, Biomedical Engeering Graduate Group, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered

  1. Comparative evaluation of average glandular dose and image of digital mammography and film mammography in Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Nogueira, M.; Leyton, F.; Rodrigue, L. L.C.; Oliveira, M.A.; Joana, G.S.; Silva, S.D.

    2015-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The purpose of our study was to compare the technical performance of digital mammographic and screen-film mammography. A PMMA phantom with objects to simulate breast structures. For the screen/film (SF) technique the results showed that 54% mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 67% services showed inadequate performance in their processing systems, which had significant influence on the image quality. At the mean glandular dose only 44% of digital systems evaluated were compliant in all thicknesses of PMMA. The average glandular dose AGD was 90 % higher than in screen/film systems. (authors)

  2. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.

    Science.gov (United States)

    Castillo-García, Maria; Chevalier, Margarita; Garayoa, Julia; Rodriguez-Ruiz, Alejandro; García-Pinto, Diego; Valverde, Julio

    2017-07-01

    The study aimed to compare the breast density estimates from two algorithms on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and to analyze the clinical implications. We selected 561 FFDM and DBT examinations from patients without breast pathologies. Two versions of a commercial software (Quantra 2D and Quantra 3D) calculated the volumetric breast density automatically in FFDM and DBT, respectively. Other parameters such as area breast density and total breast volume were evaluated. We compared the results from both algorithms using the Mann-Whitney U non-parametric test and the Spearman's rank coefficient for data correlation analysis. Mean glandular dose (MGD) was calculated following the methodology proposed by Dance et al. Measurements with both algorithms are well correlated (r ≥ 0.77). However, there are statistically significant differences between the medians (P density median values from FFDM are, respectively, 8% and 77% higher than DBT estimations. Both algorithms classify 35% and 55% of breasts into BIRADS (Breast Imaging-Reporting and Data System) b and c categories, respectively. There are no significant differences between the MGD calculated using the breast density from each algorithm. DBT delivers higher MGD than FFDM, with a lower difference (5%) for breasts in the BIRADS d category. MGD is, on average, 6% higher than values obtained with the breast glandularity proposed by Dance et al. Breast density measurements from both algorithms lead to equivalent BIRADS classification and MGD values, hence showing no difference in clinical outcomes. The median MGD values of FFDM and DBT examinations are similar for dense breasts (BIRADS d category). Published by Elsevier Inc.

  3. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors

    International Nuclear Information System (INIS)

    Costa, K.; Nogueira, M. S.

    2015-10-01

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  5. False positive reaction due to endogenous biotin activity in glandular epithelium of decidua Reação falso positiva em epitélio glandular da decídua devido a atividade endógena de biotina

    Directory of Open Access Journals (Sweden)

    Liliana Cruz Spano

    2005-06-01

    Full Text Available Biotin-labeled probe was used in an in situ hybridisation assay to localize virus infection in formalin-fixed, paraffin embedded tissues taken from eleven abortion cases. Probes for human cytomegalovirus (HCMV, human Parvovirus B19 (B19 and human adenovirus type 2 (HAd2, were labeled with biotin-11-dUTP by nick-translation reaction. Streptavidin-alkaline-phosphatase (SAP was used to detect biotin, followed by 4-nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP solution. Positive reaction was observed in nucleus of glandular ephitelium cells of decidua either in positive or in negative control at first and second gestational trimester. The reaction was not inhibited with blocking solution for alkaline phosphatase endogenous activity and it persisted even with probes omission. The use of adequate negative control permitted to reveal the presence of nuclear biotin in glandular epithelium of decidua, responsible for false positivity in detection systems involving streptavidin biotin system (StrepABC. The stained cells resembled to cytophatic effect due to herpesvirus, which could induce further misinterpretation. The results obtained in this study strongly recommend that DNA detection by in situ hybridisation reaction in gestational endometrium should be done without using StrepABC system.Sondas marcadas com biotina foram utilizadas neste trabalho para detecção de infecção viral por hibridização in situ em tecidos fixados com formalina e embebidos em parafina de 11 casos obtidos de abortamento. Sondas para citomegalovírus humano (HCMV, parvovírus B19 humano (B19 e adenovírus humano tipo 2 (HAd2, foram marcadas com biotina-11-dUTP através da reação de nick-translation. Estreptavidina conjugada com fosfatase alcalina (SAP seguida por solução de 4-nitro-azul de tetrazolio/5-bromo-4-cloro-3-indolil fosfato (NBT/BCIP foram utilizadas para detecção da biotina após a reação de hibridização. Reação positiva foi

  6. Quality control, mean glandular dose estimate and room shielding calculation in mammography

    International Nuclear Information System (INIS)

    Rakotomalala, H.M.

    2014-01-01

    This study focuses in the importance of Radiation Protection in mammography. A good control of the radiological risk depends on the dose optimization, room shielding calculation and the quality of equipment. The work was carried out in the three private medical centers called A, B, and C. Dosimetry estimates were made on the equipment of the three centers. Values has been compared with the Diagnostic Reference Levels established by the International Atomic Energy Agency (IAEA). Conformity control of the radiological devices has also been done with the Mammographic Quality Control Kit of the INSTN-Madagascar. Verifications of shields of the room containing the mammography equipment were done by theoretical calculations using the method provided by NCRP 147. [fr

  7. Forward-scattered radiation from the compression paddle should be considered in glandular dose estimations

    International Nuclear Information System (INIS)

    Hemdal, B.

    2011-01-01

    From major protocols on dosimetry in mammography, there is no doubt that the incident air kerma should be evaluated without backscattered radiation to the dosemeter. However, forward-scattered radiation from the compression paddle is neglected. The aim of this work was to analyse the contribution of forward-scattered radiation for typical air kerma measurements. Measurements of forward-scatter were performed with a plane-parallel ionisation chamber on four mammography units. The forward-scatter contribution to the air kerma was 2-10 % and increased with the compression paddle thickness, but also with the half-value layer value. For incident air kerma in mammography, it can be as important to consider forward scattered as backscattered radiation. If an ionisation chamber is used, the compression paddle should be in contact with the chamber; otherwise the air kerma and absorbed dose will be underestimated. If a dosemeter based on semiconductors with much less sensitivity to scattered radiation is used, it is suggested that a forward-scatter factor (FSF) is applied. Based on the results of this work, FSF=1.06 will lead to a maximum error of ∼4 %. (authors)

  8. Guideline for determining the mean glandular dose according to DIN 6868-162 and threshold contrast visibility according to the quality assurance guideline for digital mammography systems.

    Science.gov (United States)

    Sommer, A; Schopphoven, S; Land, I; Blaser, D; Sobczak, T

    2014-05-01

    As part of the physico-technical quality assurance of the German breast cancer screening program, the threshold contrast visibility and the average glandular dose of every digital mammography system have to fulfill the requirements of the "European guidelines for quality assurance in breast cancer screening and diagnosis" (4th Edition). To accomplish uniform measurements in all federal states of Germany, the physical board of the reference centers developed a special guideline in 2009. Due to recent changes in the guidelines and standards, a second version of the guideline was developed by the reference centers. This guideline describes the determination of the average glandular dose as well as the CDMAM image acquisition and the CDMAM image evaluation. The determination of the threshold contrast visibility can be performed visually or automatically. The determination of the average glandular dose is based on DIN 6868 - 162 and the threshold contrast visibility test is based on the German "Quality Assurance Guideline". © Georg Thieme Verlag KG Stuttgart · New York.

  9. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C; Zhong, Y; Wang, T; Shaw, C [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

  10. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    International Nuclear Information System (INIS)

    Lai, C; Zhong, Y; Wang, T; Shaw, C

    2015-01-01

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor

  11. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors; Evaluacion de la influencia de los parametros que determinan la dosis glandular media en Mamografia utilizando diferentes detectores

    Energy Technology Data Exchange (ETDEWEB)

    Costa, K.; Nogueira, M. S., E-mail: katicostabh@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear, Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  12. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    Science.gov (United States)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  13. Plant Glandular Trichomes

    Indian Academy of Sciences (India)

    landing on the plant. Glandular trichomes in catmint (Nepeta sp.) produce nepetalactone, closely related to the aphid sex pheromone, nepetalactol. Nepetalactone can be reduced to the corresponding nepetalactol. ... Plant glandular trichomes function either as repositories or releasing sites of various chemicals. Interest in ...

  14. A comparison of mean glandular dose diagnostic reference levels within the all-digital irish national breast screening programme and the Irish symptomatic breast services

    International Nuclear Information System (INIS)

    O'Leary, D.; Rainford, L.

    2013-01-01

    Data on image quality, compression and radiation dose were collected from symptomatic breast units within the Republic of Ireland. Quantitative and qualitative data were analysed using SPSS. Recommendations of mean glandular dose (MGD) diagnostic reference levels were made at various levels for film-screen and full field digital mammography units to match levels published worldwide. MGDs received by symptomatic breast patients within Ireland are higher than those received in the all-digital Irish Breast Screening service; 55-65 mm breast: 1.75 mGy (screening) vs. 2.4 mGy (symptomatic) at the 95. percentile; various reasons are proposed for the differences. MGDs achieved in the screening service may be lower because of the exacting requirements for radiographer training, characteristics of the patients and equipment quality assurance levels. More precise imaging guidelines, standards and training of symptomatic radiographers performing mammography are suggested to remediate MGDs delivered to the breasts of Irish women attending the symptomatic breast services. (authors)

  15. A Survey On Mean Glandular Dose From Full-Field Digital Mammography Systems, Operate Using Mo/ Mo And W/Rh Target/ Filter Combinations

    International Nuclear Information System (INIS)

    Noriah Jamal; Siti Selina Abdul Hamid; Humairah Samad Cheung; Siti Kamariah Che Mohamed; Ellyda Muhammed Nordin; Radhiana Hassan; Rehir Dahalan

    2013-01-01

    We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/ Molybdenum (Mo/ Mo) and Tungsten/ Rhodium (W/ Rh) target/ filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/ Rh, while the second centre operates using an Mo/ Mo target/ filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/ Mo and W/ Rh target/ filter combinations present the same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the increasing of CBT. However, FFDM system operates using Mo/ Mo gives higher MGD as compared with FFDM system operates using W/ Rh. (author)

  16. Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose

    International Nuclear Information System (INIS)

    Berns, Eric A.; Hendrick, R. Edward; Cutter, Gary R.

    2003-01-01

    Contrast-detail experiments were performed to optimize technique factors for the detection of low-contrast lesions using a silicon diode array full-field digital mammography (FFDM) system under the conditions of a matched average glandular dose (AGD) for different techniques. Optimization was performed for compressed breast thickness from 2 to 8 cm. FFDM results were compared to screen-film mammography (SFM) at each breast thickness. Four contrast-detail (CD) images were acquired on a SFM unit with optimal techniques at 2, 4, 6, and 8 cm breast thicknesses. The AGD for each breast thickness was calculated based on half-value layer (HVL) and entrance exposure measurements on the SFM unit. A computer algorithm was developed and used to determine FFDM beam current (mAs) that matched AGD between FFDM and SFM at each thickness, while varying target, filter, and peak kilovoltage (kVp) across the full range available for the FFDM unit. CD images were then acquired on FFDM for kVp values from 23-35 for a molybdenum-molybdenum (Mo-Mo), 23-40 for a molybdenum-rhodium (Mo-Rh), and 25-49 for a rhodium-rhodium (Rh-Rh) target-filter under the constraint of matching the AGD from screen-film for each breast thickness (2, 4, 6, and 8 cm). CD images were scored independently for SFM and each FFDM technique by six readers. CD scores were analyzed to assess trends as a function of target-filter and kVp and were compared to SFM at each breast thickness. For 2 cm thick breasts, optimal FFDM CD scores occurred at the lowest possible kVp setting for each target-filter, with significant decreases in FFDM CD scores as kVp was increased under the constraint of matched AGD. For 2 cm breasts, optimal FFDM CD scores were not significantly different from SFM CD scores. For 4-8 cm breasts, optimum FFDM CD scores were superior to SFM CD scores. For 4 cm breasts, FFDM CD scores decreased as kVp increased for each target-filter combination. For 6 cm breasts, CD scores decreased slightly as k

  17. Dose Vocal: uma revisão integrativa da literatura

    Directory of Open Access Journals (Sweden)

    Joana Perpétuo Assad

    Full Text Available RESUMO O objetivo da pesquisa foi realizar uma revisão da literatura referente aos tipos de dose vocal e aos resultados destas medidas em diferentes situações comunicativas. Houve levantamento da literatura nacional e internacional, publicada nos idiomas Inglês, Espanhol ou Português, utilizando-se as bases de dados MEDLINE, LILACS, IBECS e ISI (Web of Science, dos últimos 21 anos, cujos artigos estavam disponíveis na íntegra. Quinze estudos contemplaram os critérios propostos. A maioria dos artigos estudou professores, visto que são mais vulneráveis para a ocorrência de disfonia. Os tipos de dose encontrados foram porcentagem de fonação, dose temporal, dose cíclica, dose de distância, dose de energia radiada e dose de energia dissipada. O aumento da dose vocal está associado ao uso excessivo e prolongado da voz na atividade docente, principalmente entre os professores da educação infantil e os de canto. As altas doses vocais correlacionam-se também à presença de disfonia, ao maior nível de ruído ambiental, à grande variação prosódica na fala e à autopercepção de fadiga vocal. Pacientes com disfonia comportamental (nódulos e pólipos apresentam maiores doses vocais que pacientes com outros quadros disfônicos. Fatores como repouso de voz e uso do amplificador vocal indicam a diminuição da dose da voz.

  18. Evaluation of absorbed radiation dose in mammography using Monte Carlo simulation; Avaliacao da dose absorvida em mamografia usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Bruno L.; Tomal, Alessandra [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin

    2016-07-01

    Mammography is the main tool for breast cancer diagnosis, and it is based on the use of X-rays to obtain images. However, the glandular tissue present within the breast is highly sensitive to ionizing radiation, and therefore requires strict quality control in order to minimize the absorbed dose. The quantification of the absorbed dose in the breast tissue can be done by using Monte Carlo simulation, which allows a detailed study of the deposition of energy in different regions of the breast. Besides, the results obtained from the simulation can be associated with experimental data and provide values of dose interest, such as the dose deposited in glandular tissue. (author)

  19. Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography

    International Nuclear Information System (INIS)

    Jansen, J T M; Veldkamp, W J H; Thijssen, M A O; Woudenberg, S van; Zoetelief, J

    2005-01-01

    The nationwide breast cancer screening programme using mammography has been in full operation in the Netherlands since 1997. Quality control of the screening programme has been assigned to the National Expert and Training Centre for Breast Cancer Screening. Limits are set to the mean glandular dose and the centre monitors these for all facilities engaged in the screening programme. This procedure is restricted to the determination of the entrance dose on a 5 cm thick polymethylmethacrylate (PMMA) phantom. The mean glandular dose for a compressed breast is estimated from these data. Individual breasts may deviate largely from this 5 cm PMMA breast model. Not only may the compressed breast size vary from 2 to 10 cm, but breast composition varies also. The mean glandular dose is dependent on the fraction of glandular tissue (glandularity) of the breast. To estimate the risk related to individual mammograms requires the development of a method for determination of the glandularity of individual breasts. A method has been developed to derive the glandularity using the attenuation of mammography x-rays in the breast. The method was applied to a series of mammograms at a screening unit. The results, i.e., a glandularity of 93% within the range of 0 to 1, were comparable with data in the literature. The glandularity as a function of compressed breast thickness is similar to results from other investigators using differing methods

  20. Comparative evaluation of average glandular dose and breast cancer detection between single-view digital breast tomosynthesis (DBT) plus single-view digital mammography (DM) and two-view DM: correlation with breast thickness and density

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Ui; Chang, Jung Min; Bae, Min Sun; Lee, Su Hyun; Cho, Nariya; Seo, Mirinae; Kim, Won Hwa; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2015-01-15

    To compare the average glandular dose (AGD) and diagnostic performance of mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus cranio-caudal (CC) digital mammography (DM) with two-view DM, and to evaluate the correlation of AGD with breast thickness and density. MLO and CC DM and DBT images of both breasts were obtained in 149 subjects. AGDs of DBT and DM per exposure were recorded, and their correlation with breast thickness and density were evaluated. Paired data of MLO DBT plus CC DM and two-view DM were reviewed for presence of malignancy in a jack-knife alternative free-response ROC (JAFROC) method. The AGDs of both DBT and DM, and differences in AGD between DBT and DM (ΔAGD), were correlated with breast thickness and density. The average JAFROC figure of merit (FOM) was significantly higher on the combined technique than two-view DM (P = 0.005). In dense breasts, the FOM and sensitivity of the combined technique was higher than that of two-view DM (P = 0.003) with small ΔAGD. MLO DBT plus CC DM provided higher diagnostic performance than two-view DM in dense breasts with a small increase in AGD. (orig.)

  1. Comparative evaluation of average glandular dose and breast cancer detection between single-view digital breast tomosynthesis (DBT) plus single-view digital mammography (DM) and two-view DM: correlation with breast thickness and density

    International Nuclear Information System (INIS)

    Shin, Sung Ui; Chang, Jung Min; Bae, Min Sun; Lee, Su Hyun; Cho, Nariya; Seo, Mirinae; Kim, Won Hwa; Moon, Woo Kyung

    2015-01-01

    To compare the average glandular dose (AGD) and diagnostic performance of mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus cranio-caudal (CC) digital mammography (DM) with two-view DM, and to evaluate the correlation of AGD with breast thickness and density. MLO and CC DM and DBT images of both breasts were obtained in 149 subjects. AGDs of DBT and DM per exposure were recorded, and their correlation with breast thickness and density were evaluated. Paired data of MLO DBT plus CC DM and two-view DM were reviewed for presence of malignancy in a jack-knife alternative free-response ROC (JAFROC) method. The AGDs of both DBT and DM, and differences in AGD between DBT and DM (ΔAGD), were correlated with breast thickness and density. The average JAFROC figure of merit (FOM) was significantly higher on the combined technique than two-view DM (P = 0.005). In dense breasts, the FOM and sensitivity of the combined technique was higher than that of two-view DM (P = 0.003) with small ΔAGD. MLO DBT plus CC DM provided higher diagnostic performance than two-view DM in dense breasts with a small increase in AGD. (orig.)

  2. Glandularity estimation in Japanese women by using a breast model made from mammographic findings of European women

    International Nuclear Information System (INIS)

    Kawaguchi, Ai; Matsunaga, Yuta; Chida, Koichi; Asada, Yasuki; Suzuki, Shoichi

    2016-01-01

    This study aimed to estimate breast glandularity in Japanese women using patient exposure conditions and tissue-equivalent materials by a conventional method. Typical glandularities in Japanese women were compared with those in European women to verify the validity of the average glandular dose estimation manual based on the EUREF protocol. Glandularity was estimated from the data of 600 patients and the model breast of the tissue-equivalent materials which had various amounts of glandular contents and thicknesses. The model breasts were measured to examine the relationships between the thickness of the glandular contents and tube loading by using an automatic exposure control system. Then, equations were established to determine glandularity from patient data. The mean glandularity in the highest compressed breast thickness (CBT) group of 36–45 mm was 72%. The mean CBT of the 184 (31%) patients with glandularities exceeding 100% was 31 mm. Glandularities in patients with CBT of 30–70 mm in the present study were higher compared to those in European women by approximately 10–20%. The results suggest that the model breast of European women might not be a suitable reference standard for more than 30% of Japanese women, who have breasts with lower CBT. (author)

  3. Comportamento da área foliar da videira “Isabel” submetida a diferentes tipos e doses de biofertilizantes

    Directory of Open Access Journals (Sweden)

    Olivânia dos Santos Nascimento

    2014-06-01

    Full Text Available Objetivou-se verificar o efeito da aplicação de diferentes tipos e doses de biofertilizante, na área foliar da videira ‘Isabel’ em cultivo orgânico nas condições edafoclimáticas de Catolé do Rocha-PB. Estudou-se os efeitos de 5 tipos de biofertilizante biofertilizante e 8 doses na área foliar da videira ‘Isabel’ após a primeira poda de produção. O experimento foi conduzido sob condições de campo, em área pertencente à Universidade Estadual da Paraíba, Campus IV. O delineamento adotado foi o de blocos casualizados, com 40 tratamentos, no esquema fatorial 5 x 8, com 4  repetições, totalizando 160 parcelas experimentais, os tratamentos consistiram em aplicações crescentes de diferentes biofertilizante, aplicados de forma independente. O valor da área foliar unitária da videira Isabel aumentou com o incremento da dose do biofertilizante B1 até um limite ótimo de 0,93 L/planta/aplicação; o valor da área foliar unitária diminuiu com o aumento da dose do biofertilizante B1 acima do limite ótimo de 0,93 L/planta/aplicação; a utilização de biofertilizante enriquecido com farinha de rocha e leguminosa (B3 proporcionou maior área foliar unitária e área foliar da planta da videira Isabel.

  4. Immunohistochemical characterization of glandular elements in glandular cardiac myxoma: Study of six cases

    Directory of Open Access Journals (Sweden)

    Devajit Nath

    2017-01-01

    Full Text Available Back ground: Glandular cardiac myxoma has varying clinical presentation with uncertain histogenesis and debatable immunohistochemical profile. Glandular epithelial differentiations are rare phenomenon known to be present as an intrinsic component of the tumor. The origin of the glands has been attributed to epithelial differentiation of a totipotent cardiomyogenic precursor cells or the entrapped foregut rests in the tumor. Materials and Methods: Retrospective study includes six cases of glandular cardiac myxoma collected over a perior of 4 years. Sections were examined to define the histogenesis, histological and immunohistochemical profile of the glandular elements. Results: Incidence of glandular cardiac myxoma was 6.6% with a male to female ratio of 1:2.Mean age was 49.9 years. Left atrium was the commonest site. Five were sporadic and one was familial. Chest pain and dyspnea were the commonest clinical symptoms. Histologically all myxoma showed well formed glandular structures with typical myxomatous area. No atypia, mitosis or necrosis was identified in the glandular elements. Markers in six cases of glandular cardiac myxoma were immunopositive for CK7, CK 19, EMA, CEA, focally for E-cadherin while immunonegative for CK20, Chromogranin, Synaptophysin, calretenin, vimentin, B-catenin, TTF-1 and GCDFP-15 favoring enteric differentiation. Conclusion: Glandular cardiac myxoma is a rare entity which shows characteristics similar to those of classical cardiac myxoma with benign glandular elements showing enteric differentiation. Complete surgical excision is the treatment of choice with good prognosis. It is important to recognize this entity to avoid an erroneous diagnosis of metastatic adenocarcinoma.

  5. Comportamento da área foliar da videira “Isabel” submetida a diferentes tipos e doses de biofertilizantes

    OpenAIRE

    Olivânia dos Santos Nascimento; Aldair Souza Medeiros; Atos Tavares Gomes; Fábio Itano dos Santos Alves; José Geraldo Rodrigues dos Santos

    2014-01-01

    Objetivou-se verificar o efeito da aplicação de diferentes tipos e doses de biofertilizante, na área foliar da videira ‘Isabel’ em cultivo orgânico nas condições edafoclimáticas de Catolé do Rocha-PB. Estudou-se os efeitos de 5 tipos de biofertilizante biofertilizante e 8 doses na área foliar da videira ‘Isabel’ após a primeira poda de produção. O experimento foi conduzido sob condições de campo, em área pertencente à Universidade Estadual da Paraíba, Campus IV. O delineamento adotado foi o d...

  6. Maxilary glandular odontogenic cyst: case report = Cisto odontogênico glandular em maxila: relato de caso

    Directory of Open Access Journals (Sweden)

    Cardoso, Juliana Andrade

    2015-01-01

    Full Text Available Objetivo: O presente trabalho objetiva relatar um caso clínico de cisto odontogênico glandular (COG em maxila, cisto de desenvolvimento raro que pode apresentar comportamento agressivo e recidivante, dando ênfase no tratamento e proservação desta doença. Relato de Caso: Paciente faioderma, gênero feminino, 36 anos, foi encaminhada pelo Ortodontista por apresentar aumento de volume em maxila com abaulamento e crepitação. Foram realizadas radiografias e punção aspirativa. Uma vez observado o conteúdo da lesão, foi realizada a biópsia incisional e iniciada a descompressão com colocação de dreno rígido. Tendo a confirmação do diagnóstico para COG, a paciente foi submetida à cirurgia para remoção do cisto maxilar, através da enucleação cirúrgica, curetagem e osteotomia periférica. Conclusões: O COG é uma patologia incomum, recentemente reconhecida, cujo comportamento biológico pouco ainda se sabe. Sugere-se, portanto, a realização de investigações futuras sobre critérios para classificação de variáveis comumente utilizadas em estudos epidemiológicos, na tentativa de padronizar e possibilitar comparação entre estudos, todavia, para auxiliar em um diagnóstico bem sucedido

  7. Caracterização e ontogenia dos tricomas glandulares de Ocimum selloi Benth. - Lamiaceae Characterization and ontogeny of the glandular trichomes of Ocimum selloi Benth. (Lamiaceae

    Directory of Open Access Journals (Sweden)

    Letícia de Almeida Gonçalves

    2010-12-01

    Full Text Available Ocimum selloi Benth. (Lamiaceae é uma espécie nativa da América do Sul e na medicina popular tem sido usada devido suas propriedades analgésica, anti-inflamatória e antiespasmódica. O objetivo do presente trabalho foi identificar os tipos de tricomas glandulares que ocorrem nos órgãos vegetativos e reprodutivos de O. selloi e determinar a ontogenia desses tricomas. Ramos laterais em início de formação, folhas totalmente expandidas, flores em diferentes estádios de diferenciação, amostras de caule e do eixo das inflorescências foram analisados em microscopias de luz e eletrônica de varredura. Tricomas glandulares do tipo peltado e capitado subséssil foram observados no caule, nas folhas, no eixo da inflorescência e na superfície adaxial das sépalas. Nas sépalas foi encontrado, além dos tricomas secretores peltados e capitados subsésseis, o tricoma glandular capitado pedunculado. A ontogenia inicia-se com a expansão de uma célula protodérmica que, de acordo com a seqüência de divisões periclinais e anticlinais (ora simétricas, ora assimétricas, dá origem aos tricomas. A diferenciação dos tricomas glandulares peltados e capitados não é sincrônica e ocorre muito cedo no desenvolvimento da folha, do caule e do eixo floral.Ocimum selloi Benth. (Lamiaceae is native to South America and in traditional medicine has been used due to its analgesic, anti-inflammatory, and antispasmodic properties. The aim of this study was to identify the types of glandular trichomes that occur on the vegetative and reproductive organs of O. selloi and to determine trichome ontogeny. Lateral branches at the initial formation phase, fully opened leaves, flowers at different differentiation stages, and stem and inflorescence axes were analyzed under light and scanning electron microscopy. Glandular trichomes of the peltate and subsessile capitate types were observed on the stem, leaves, inflorescence axis and the adaxial surface of the

  8. TU-F-18C-05: Evaluation of a Method to Calculate Patient-Oriented MGD Coefficients Using Estimates of Glandular Tissue Distribution

    International Nuclear Information System (INIS)

    Porras-Chaverri, M; Galavis, P; Bakic, P; Vetter, J

    2014-01-01

    Purpose: Evaluate mammographic mean glandular dose (MGD) coefficients for particular known tissue distributions using a novel formalism that incorporates the effect of the heterogeneous glandular tissue distribution, by comparing them with MGD coefficients derived from the corresponding anthropomorphic computer breast phantom. Methods: MGD coefficients were obtained using MCNP5 simulations with the currently used homogeneous assumption and the heterogeneously-layered breast (HLB) geometry and compared against those from the computer phantom (ground truth). The tissue distribution for the HLB geometry was estimated using glandularity map image pairs corrected for the presence of non-glandular fibrous tissue. Heterogeneity of tissue distribution was quantified using the glandular tissue distribution index, Idist. The phantom had 5 cm compressed breast thickness (MLO and CC views) and 29% whole breast glandular percentage. Results: Differences as high as 116% were found between the MGD coefficients with the homogeneous breast core assumption and those from the corresponding ground truth. Higher differences were found for cases with more heterogeneous distribution of glandular tissue. The Idist for all cases was in the [−0.8 − +0.3] range. The use of the methods presented in this work results in better agreement with ground truth with an improvement as high as 105 pp. The decrease in difference across all phantom cases was in the [9 − 105] pp range, dependent on the distribution of glandular tissue and was larger for the cases with the highest Idist values. Conclusion: Our results suggest that the use of corrected glandularity image pairs, as well as the HLB geometry, improves the estimates of MGD conversion coefficients by accounting for the distribution of glandular tissue within the breast. The accuracy of this approach with respect to ground truth is highly dependent on the particular glandular tissue distribution studied. Predrag Bakic discloses current

  9. Enhancement of lymphocyte proliferation by mouse glandular kallikrein.

    Science.gov (United States)

    Hu, Z Q; Murakami, K; Ikigai, H; Shimamura, T

    1992-03-01

    Mouse glandular kallikrein (mGK) strongly enhanced the spontaneous and mitogen-induced proliferation of lymphocytes. Both blast formation and 3H-TdR incorporation were dose-dependently enhanced at the same time many cells were killed. The enhancing activity was independent of EGF, because EGF-binding proteins (mGK-9 in mGK-6,9 mixture and mGK-13), renal kallikrein (mGK-6) and human kallikrein all displayed the same enhancement. A serine proteinase inhibitor, diisopropyl fluorophosphate, could block the enhancement by mGK. The new function suggests that mGK is important in the immune system as a regulatory molecule.

  10. Efeitos das isoflavonas em altas doses sobre o útero da rata Effects of high-dose isoflavones on rat uterus

    Directory of Open Access Journals (Sweden)

    Adriana Aparecida Ferraz Carbonel

    2011-10-01

    of eosinophils in the lamina propria were analyzed. ANOVA and the Tukey-Kramer test were used for statistical analyses. RESULTS: Uterine weight, endometrial glandular area, and number of glands and eosinophils were all higher in GES250 > G125 than in the other groups (GES250 > GES125 > GES42 = GCtrl; p < 0.05. Morphological data showed signs of endometrial proliferation upon treatment with genistein, especially in animals in GES125 and GES250 compared to other groups. In all animals in GES250, signs of uterine squamous metaplasia were observed. CONCLUSION: A short treatment period with high daily doses of isoflavones can promote endometrial squamous metaplasia in ovariectomized rats.

  11. Morphological differentiation of non-glandular and glandular trichomes on Marrubium vulgare L.

    Directory of Open Access Journals (Sweden)

    Marta Dmitruk

    2014-04-01

    Full Text Available Marrubium vulgare L., commonly known as a white horehound or common horehound, belongs to the plant family Lamiaceae. It is a perennial aromatic herb which grows naturally in Europe, Asia, and America. Since ancient Egypt, this species has been known as a remedy for upper respiratory tract ailments. Nowadays, horehound is used in herbal medicine for treatment of liver diseases, biliary tract disorders, and for increasing the appetite and supporting the function of the stomach. The main biologically active substances in M. vulgare organs are: marrubiin, tannins, essential oils, and ursolic acid. The paper presents micromorphological analyses of non-glandular and glandular trichomes of M. vulgare. The research material was sampled from the plant collection in the Botanical Garden of the Maria Curie-Sklodowska University in Lublin (51°14′ N, 22°34′ E. The above-ground parts of horehound were collected during the flowering period in July 2013. Using light microscopy (LM and scanning electron microscopy (SEM, the types and sizes of trichomes from the stem, leaf, calyx, and corolla were investigated. The results of the microscopic observations show that the surfaces of M. vulgare vegetative and reproductive organs are densely clothed with glandular and non-glandular trichomes. The glandular trichomes are of two main types: peltate and capitate. Peltate trichomes consist of a short stalk cell and a large head with secretory cells arranged in a circle. The height of a mature trichome is about 31.33 μm and the diameter of the head is 31.47 μm. The substance produced by secretory cells passes through the apical walls and accumulates within a space between the cuticle and the cell wall layer. Capitate long trichomes with a basal cell, long stalk, neck cell, and a unicellular head are 36.65 μm long and the diameter of the head is about 15.6 μm. There are two types of short capitate trichomes: with a bicellular head and a unicellular stalk and with

  12. Avaliação da medida do comprimento do colo e da ausência do eco glandular endocervical para predição do parto pré-termo Evaluation of risk for preterm delivery by measurement of uterine cervix and cervical gland area

    Directory of Open Access Journals (Sweden)

    Claudio Rodrigues Pires

    2004-04-01

    Full Text Available OBJETIVO: verificar a prevalência do sinal eco glandular endocervical (EGE e o comprimento cervical menor ou igual a 20 mm em gestantes entre a 21ª e a 24ª semana e comparar estes sinais ecográficos como fatores indicadores de parto pré-termo espontâneo. MÉTODOS: estudo prospectivo transversal no qual foram incluídas 361 gestantes da população geral, para realização de exame ultra-sonografico em idade gestacional entre a 21ª a 24ª semana. Os critérios de exclusão do estudo foram malformações müllerianas, gestações múltiplas, malformações fetais, óbito fetal, alterações da quantidade de líquido amniótico, placenta com inserção segmentar, antecedentes de cirurgia no colo uterino (conização, amputação, cerclagem e procedimentos cirúrgicos durante a gestação. Após a realização do exame ultra-sonográfico obstétrico morfológico efetuado por via abdominal, seguiu-se o exame ecográfico por via vaginal para observação de uma faixa hipoecóica ou hiperecóica adjacente ao canal endocervical correpondente às glândulas do epitélio endocervical (EGE e mensuração do comprimento cervical. As variáveis qualitativas são representadas por freqüência absoluta e relativa, ao passo que as variáveis quantitativas, por média, desvio-padrão, mediana e valores mínimo e máximo. A associação entre as variáveis qualitativas foi avaliada pelo teste c² ou teste exato de Fisher. Para cada variável estudada, foi calculado o risco relativo seguido do intervalo com 95% de confiança. A técnica de análise de regressão logística univariada foi utilizada para verificar, entre as variáveis estudadas, quais foram indicativas de parto pré-termo espontâneo. O nível de significância adotado foi de 95% (alfa = 5% e descritivos (p iguais ou inferiores a 0,05 foram considerados significantes. RESULTADOS: a incidência do parto pré-termo espontâneo foi de 5,0%. O comprimento do colo uterino revelou-se igual ou

  13. Calculation of dose equivalents for photon skyshine production; Calculo da dose equivalente para fotons decorrente da producao de skyshine

    Energy Technology Data Exchange (ETDEWEB)

    Frota, Marco A.; Kelecom, Alphonse [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Biologia Geral. Lab. de Radiobiologia e Radiometria (LARARA)]. E-mail: egbakel@vm.uff.br

    2005-07-01

    Some radiation facilities are designed with little shielding in the ceiling above the accelerator. A problem may then arise as a result of the radiation scattered by the atmosphere to points at ground level outside the treatment room. Stray radiation of this type is referred to as skyshine, and the National Council on Radiation Protection and Measurements Report No. 51 (NCRP 1977) gives methods for the calculation of skyshine for accelerator facilities. McGinley (1993) has compared skyshine measurements made at an 18 MeV medical accelerator facility with values calculated using the techniques presented in NCRP Report No. 51. Measurements were made of the photon levels outside a treatment room housing a Varian 2100 deg C. The roof above the accelerator was designed for weather protection only and offered little shielding for the primary beam and scattered radiation. The distance from the treatment room floor to the roof was 4.27 m, and the primary walls were constructed of concrete 2.0 m thick.The secondary walls were fabricated of concrete 0.99 m thick. The results for the photon skyshine rate dose as a function of distance from the isocenter using Monte Carlo code, are compared with those in NCRP publication 74 and measured obtained. The photon skyshine dose rates simulated for real clinic spectra transmitted through roof range from 4.7 to 14.6 nSv.s{sup -1}. (author)

  14. Estimation of glandular content rate and statistical analysis of the influence of age group and compressed breast thickness on the estimated value

    International Nuclear Information System (INIS)

    Ohmori, Naoki; Ashida, Kenji; Fujita, Osamu

    2003-01-01

    Because the glandular content rate is an important factor in evaluating breast cancer detection and average glandular dose, it is important in mammography research to estimate and analyze this rate. The purpose of this study was to obtain a formula for statistical estimation of the glandular content rate, to clarify statistically the influence of age group and compressed breast thickness (CBT) on estimating the glandular content rate, and to show statistically the general relation between glandular content rate and the factors of age and CBT. The subjects were 740 Japanese women aged 20-91 years (mean±SD: 48.3±12.8 years) who had undergone mammography. In our study, the glandular content rate was statistically estimated from age group, mAs-value, and CBT when subjects underwent mammography, from a phantom simulation, and from MR images of the breast. In addition, multivariate analysis was carried to examine statistically the influence of age group and CBT on glandular content rate. The mean glandular content rate as estimated by age group was as follows: 35.6% for those in their 20s, 33.4% in the 30s, 27.5% in the 40s, 23.8% in the 50s, and 21.8% in those 60 and over. The rate for the subjects as a whole was 27.1%. This study indicated that overestimation occurred if the estimated value of the glandular content rate was not corrected in the 3D-measurement by MRI. In addition, this study showed that the statistical influence on glandular content rate was significantly larger for CBT than age. (author)

  15. Structure and histochemistry of the glandular trichomes on the ...

    African Journals Online (AJOL)

    The glandular trichomes were classified into two subpopulations, namely the peltate and capitate glandular trichomes. The former was characterized by a short stalk and a large four-celled secretory head, while the latter was further subdivided into two groups; one has a short unicellular stalk and two-cellular head (type I), ...

  16. Elimination of salmonella from animal glandular products.

    Science.gov (United States)

    De Fiebre, C W; Burck, K T; Feldman, D

    1969-03-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin-a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination.

  17. Elimination of Salmonellae from Animal Glandular Products

    Science.gov (United States)

    De Fiebre, Conrad W.; Burck, Kenneth T.; Feldman, David

    1969-01-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin—a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination. PMID:5780395

  18. Glandular odontogenic cyst: A case report

    International Nuclear Information System (INIS)

    Tambawaia, Shahnaz S.; Karjodkar, Freny R.; Yadav, Archana; Sansare, Kaustubh; Sontakke, Subodh

    2014-01-01

    Glandular odontogenic cysts (GOCs) are rare intrabony solitary or multiloculated cysts of odontogenic origin. The importance of GOCs lies in the fact that they exhibit a propensity for recurrence similar to keratocystic odontogenic tumors and that they may be confused microscopically with central mucoepidermoid carcinoma. Thus, the oral and maxillofacial radiologists play an important role in definitive diagnosis of GOC based on distinctive cases; though they are rare. In large part, this is due to the GOC's complex and frequently non-specific histopathology. This report describes a case of GOC occurrence in the posterior mandibular ramus region in a 17-year-old female, which is a rare combination of site, age, and gender for occurrence.

  19. Glandular odontogenic cyst: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tambawaia, Shahnaz S.; Karjodkar, Freny R.; Yadav, Archana; Sansare, Kaustubh; Sontakke, Subodh [Nair Hospital Dental College, Mumbai (India)

    2014-03-15

    Glandular odontogenic cysts (GOCs) are rare intrabony solitary or multiloculated cysts of odontogenic origin. The importance of GOCs lies in the fact that they exhibit a propensity for recurrence similar to keratocystic odontogenic tumors and that they may be confused microscopically with central mucoepidermoid carcinoma. Thus, the oral and maxillofacial radiologists play an important role in definitive diagnosis of GOC based on distinctive cases; though they are rare. In large part, this is due to the GOC's complex and frequently non-specific histopathology. This report describes a case of GOC occurrence in the posterior mandibular ramus region in a 17-year-old female, which is a rare combination of site, age, and gender for occurrence.

  20. Os curiosos xenoimplantes glandulares do doutor Voronoff

    OpenAIRE

    Cuperschmid,Ethel Mizrahy; Campos,Tarcisio Passos Ribeiro de

    2007-01-01

    O presente artigo trata da visita do médico Serge Voronoff ao Brasil durante as Jornadas Médicas de 1928 e a subseqüente demonstração de sua técnica de xenotransplante diante da classe médica. Recorreu-se a jornais da época para ilustrar a natureza do imaginário popular em torno da cirurgia controversa e de seus pretensos milagres para a preservação da saúde e a manutenção da vida. A iniciativa de Voronoff abriu espaço para que outros profissionais da medicina relatassem sua prática cirúrgica...

  1. Dr. Voronoff's curious glandular xeno-implants

    OpenAIRE

    Cuperschmid, Ethel Mizrahy; Campos, Tarcisio Passos Ribeiro de

    2007-01-01

    O presente artigo trata da visita do médico Serge Voronoff ao Brasil durante as Jornadas Médicas de 1928 e a subseqüente demonstração de sua técnica de xenotransplante diante da classe médica. Recorreu-se a jornais da época para ilustrar a natureza do imaginário popular em torno da cirurgia controversa e de seus pretensos milagres para a preservação da saúde e a manutenção da vida. A iniciativa de Voronoff abriu espaço para que outros profissionais da medicina relatassem sua prática cirúrgica...

  2. Digital mammography screening: average glandular dose and first performance parameters

    International Nuclear Information System (INIS)

    Weigel, S.; Girnus, R.; Czwoydzinski, J.; Heindel, W.; Decker, T.; Spital, S.

    2007-01-01

    Purpose: The Radiation Protection Commission demanded structured implementation of digital mammography screening in Germany. The main requirements were the installation of digital reference centers and separate evaluation of the fully digitized screening units. Digital mammography screening must meet the quality standards of the European guidelines and must be compared to analog screening results. We analyzed early surrogate indicators of effective screening and dosage levels for the first German digital screening unit in a routine setting after the first half of the initial screening round. Materials and Methods: We used three digital mammography screening units (one full-field digital scanner [DR] and two computed radiography systems [CR]). Each system has been proven to fulfill the requirements of the National and European guidelines. The radiation exposure levels, the medical workflow and the histological results were documented in a central electronic screening record. Results: In the first year 11,413 women were screened (participation rate 57.5 %). The parenchymal dosages for the three mammographic X-ray systems, averaged for the different breast sizes, were 0.7 (DR), 1.3 (CR), 1.5 (CR) mGy. 7 % of the screened women needed to undergo further examinations. The total number of screen-detected cancers was 129 (detection rate 1.1 %). 21 % of the carcinomas were classified as ductal carcinomas in situ, 40 % of the invasive carcinomas had a histological size ≤ 10 mm and 61 % < 15 mm. The frequency distribution of pT-categories of screen-detected cancer was as follows: pTis 20.9 %, pT1 61.2 %, pT2 14.7 %, pT3 2.3 %, pT4 0.8 %. 73 % of the invasive carcinomas were node-negative. (orig.)

  3. Avaliacao da seguranca de diferentes doses de suplementos de acido folico em mulheres do Brasil

    Directory of Open Access Journals (Sweden)

    Quenia dos Santos

    2013-10-01

    Full Text Available OBJETIVO Avaliar a distribuição da ingestão de ácido fólico e a segurança de diferentes doses de suplementos em mulheres em idade reprodutiva. MÉTODOS Foram utilizados dados de consumo a partir de dois dias não consecutivos de registro alimentar de 6.837 mulheres em idade reprodutiva (19 a 40 anos participantes do Inquérito Nacional de Alimentação, módulo da Pesquisa de Orçamentos Familiares 2008-2009. Médias e percentis de consumo habitual de folato natural e ácido fólico foram estimados utilizando o método do National Cancer Institute . Cinco cenários foram simulados somando-se diferentes doses diárias de fortificação (400 mcg, 500 mcg, 600 mcg, 700 mcg e 800 mcg ao ácido fólico oriundo dos alimentos consumidos pelas mulheres. Comparou-se o total de ácido fólico (dieta + suplemento com o nível máximo de ingestão tolerável (UL = 1.000 mcg para definir a dose segura de suplementação. RESULTADOS Mulheres com ingestão habitual de ácido fólico acima do nível máximo de ingestão tolerável foram observadas para doses de suplemento de 800 mcg (7,0% das mulheres. Abaixo desse valor, qualquer dose de suplementação mostrou-se segura. CONCLUSÕES O uso de suplementos de até 700 mcg de ácido fólico mostrou-se seguro.

  4. Structure and distribution of glandular and non-glandular trichomes on above-ground organs in Inula helenium L. (Asteraceae

    Directory of Open Access Journals (Sweden)

    Aneta Sulborska

    2014-01-01

    Full Text Available Micromorphology and distribution of glandular and non-glandular trichomes on the above-ground organs of Inula helenium L. were investigated using light and scanning electron microscopy (SEM. Two types of biseriate glandular trichomes, i.e. sessile and stalk hairs, and non-glandular trichomes were recorded. Sessile glandular trichomes were found on all examined I. helenium organs (with their highest density on the abaxial surface of leaves and disk florets, and on stems, whereas stalk glandular trichomes were found on leaves and stems. Sessile trichomes were characterised by a slightly lower height (58–103 μm and width (32–35 μm than the stalk trichomes (62–111 μm x 31–36 μm. Glandular hairs were composed of 5–7 (sessile trichomes or 6–9 (stalk trichomes cell tiers. Apical trichome cell tiers exhibited features of secretory cells. Secretion was accumulated in subcuticular space, which expanded and ruptured at the top, and released its content. Histochemical assays showed the presence of lipids and polyphenols, whereas no starch was detected. Non-glandular trichomes were seen on involucral bracts, leaves and stems (more frequently on involucral bracts. Their structure comprised 2–9 cells; basal cells (1–6 were smaller and linearly arranged, while apical cells had a prozenchymatous shape. The apical cell was the longest and sharply pointed. Applied histochemical tests revealed orange-red (presence of lipids and brow colour (presence of polyphenols in the apical cells of the trichomes. This may suggest that beside their protective role, the trichomes may participate in secretion of secondary metabolites.

  5. Radiation doses in mammography as planning parameters for premature breast cancer tracking programs; Doses de radiacao em mamografias como parametros de planejamento para programas de rastreamento do cancer precoce da mama

    Energy Technology Data Exchange (ETDEWEB)

    Souza Ferreira, Rubemar de

    1994-12-31

    Radiation doses are the main parameters applied to the evaluation of mammographic radiological impact. This study, for a sample of 407 women, were analyzed, through the thermoluminescent dosimetry, radiation doses in the surface of skin and glandular absorbed doses for cranio-caudal view. The results show the presence of a large dose range to the same mammographic procedure, which, analyzed enclosed with 585 facilities, suggest be necessary the standardization of the mammographic technique. From that results, with the additive model, the excess of breast cancer (radioinduced) and lifetime loss risk, for age groups between 30 and 70 years were estimated. Is demonstrated that the benefits from dedicated mammography, overcome the relationship among the epidemiological aspects of breast cancer and ionizing radiation as an harmful agent, which may show an important correlation for large exposed populations, point out the importance of the continuous risk and benefit evaluation to the new technologies introduced. (author). 86 refs., 40 figs., 14 tabs.

  6. Tratamento da esquitossomose mansoni pela oxamniquine em dose única, pela via oral

    Directory of Open Access Journals (Sweden)

    Aluizio Prata

    1976-06-01

    Full Text Available A oxamniquine em cápsulas foi usada no tratamento de 132 doentes com esquistossomose mansoni crônica, sendo 129 com a forma hepato-intestinal e 3 com a forma hepato-esplênica. A dose foi de 10 mg por quilo de peso corporal em 34 pacientes, 12.5 mg em 35 e 15 mg em 63. A tolerância foi excelente em 43,2% dos tratados, boa em 48,5% e satisfatória em 8,3%. As queixas mais freqüentes foram tonturas e sonolência, que aparecem logo após a ingestão da droga e são fugazes. Os exames de laboratório mostraram em um ou outro paciente somente discreta retenção de bromosulfaleina, aumento de transaminase e da bilirrubina, insuficientes para caracterizar uma hepatoxicidade evidente. O seguimento dos pacientes se prolongou por mais de quatro meses e constou de pelo menos cinco exames de fezes pelo método de sedimentação. Todos os exames foram negativos em 20 (66,66% pacientes que tomaram 10 mg, em 13 (56,52% que tomaram 12.5 mg e em 41 (89,13% que tomaram 15 mg. Excluindo-se os menores de 16 anos subiu a 95% a negatividade entre os que foram tratados com 15 mg.

  7. Estudo de dose adequada da droga RO42-1611 (Arteflene) no tratamento da malária por Plasmodium falciparum

    OpenAIRE

    SILVA, Rita do Socorro Uchôa

    1997-01-01

    A resistência crescente do P. falciparum aos antimaláricos habitualmente empregados, torna urgente a avaliação de novas drogas. O Ro 42-1611 é um antimalárico derivado da planta chinesa Arlabotrys uncinatus. Usado apenas na África em três trabalhos no tratamento da malária por P. falciparum, tem sua ação desconhecida em sul-americanos com esta doença. Apesar do efeito antimalárico ter sido comprovado, ainda não se encontrou a dose adequada para o tratamento supressivo do P. falciparum. Avalia...

  8. Resposta da soja e do eucalipto ao aumento da densidade do solo e a doses de fósforo Soybean and eucalyptus response to increased soil density and phosphorus doses

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Vitorino Ribeiro

    2010-08-01

    Full Text Available O uso agrícola e o manejo de solos de Cerrado frequentemente causam sua compactação, reduzindo sua porosidade e disponibilidade de água e nutrientes, com efeito negativo sobre o crescimento e o desenvolvimento das culturas. O presente trabalho teve por objetivo avaliar os efeitos da densidade do solo e de doses de P no crescimento da soja e do eucalipto em solos com diferentes texturas: um Latossolo Vermelho (LV muito argiloso e outro Latossolo Vermelho-Amarelo (LVA textura média. Em vasos plásticos de 1,8 L, com 1,6 dm³ de solo, foram testadas, para o LV, as densidades de 0,90, 1,10 e 1,30 kg dm-3 e as doses de 0, 100, 200, 400 e 800 mg dm-3 de P, e para o LVA, as densidades de 1,30, 1,50 e 1,70 kg dm-3 e as doses de 0, 75, 150, 300 e 600 mg dm-3 de P. As plantas de soja e de eucalipto foram colhidas 40 e 80 dias após a semeadura, respectivamente. Foram avaliadas: matéria seca da parte aérea (MSPA e de raízes (MSR, acúmulo de P na MSPA (P-PA e MSR (P-R, nas duas espécies, e altura do eucalipto. Os resultados mostraram que o aumento da densidade do solo influenciou negativamente no crescimento da soja e do eucalipto, especialmente no solo LV e nas maiores doses de P; a resposta das plantas às doses de P aplicadas foi menor com o aumento da densidade do solo; e o aumento da densidade foi mais prejudicial ao crescimento do eucalipto - espécie mais eficiente na recuperação do P aplicado aos solos. De modo geral, o efeito negativo do aumento da densidade dos solos sobre a produção de MSPA das espécies, nas doses menores de P, é compensado quando as maiores doses de P são aplicadas.Agriculture and soil management in the Cerrado can cause soil compaction, resulting in decreased porosity and water and nutrient availability, with a negative impact on plant growth and development. The objective of this study was to evaluate the effect of soil density and phosphorus doses (P on soybean and eucalyptus grown in two Cerrado oxisols with

  9. Glandular Trichomes and Essential Oil of Thymus quinquecostatus

    Directory of Open Access Journals (Sweden)

    Ping Jia

    2013-01-01

    Full Text Available The distribution and types of glandular trichomes and essential oil chemistry of Thymus quinquecostatus were studied. The glandular trichomes are distributed on the surface of stem, leaf, rachis, calyx and corolla, except petiole, pistil and stamen. Three morphologically distinct types of glandular trichomes are described. Peltate trichomes, consisting of a basal cell, a stalk cell and a 12-celled head, are distributed on the stem, leaf, corolla and outer side of calyx. Capitate trichomes, consisting of a unicellular base, a 1–2-celled stalk and a unicellular head, are distributed more diffusely than peltate ones, existing on stem, leaf, rachis and calyx. Digitiform trichomes are just distributed on the outer side of corolla, consisting of 1 basal cell, 3 stalk cells and 1 head cell. All three types of glandular trichomes can secrete essential oil, and in small capitate trichomes of rachis, all peltate trichomes and digitiform trichomes, essential oil is stored in a large subcuticular space, released by cuticle rupture, whereas, in other capitate trichomes, essential oil crosses the thin cuticle. The essential oil of T. quinquecostatus is yellow, and its content is highest in the growth period. 68 constituents were identified in the essential oils. The main constituent is linalool.

  10. Cloning of a sesquiterpene synthase from Lavandula x intermedia glandular trichomes.

    Science.gov (United States)

    Sarker, Lukman S; Demissie, Zerihun A; Mahmoud, Soheil S

    2013-11-01

    The essential oil (EO) of Lavandula is dominated by monoterpenes, but can also contain small amounts of sesquiterpenes, depending on species and environmental conditions. For example, the sesquiterpene 9-epi-caryophyllene can make up to 8 % of the EO in a few species, including those commercially propagated for EO production. Here, we report the cloning and functional characterization of 9-epi-caryophyllene synthase (LiCPS) from the glandular trichomes of Lavandula x intermedia, cv. Grosso. The 1,617 bp open reading frame of LiCPS, which did not encode a transit peptide, was expressed in Escherichia coli and the recombinant protein purified by Ni-NTA agarose affinity chromatography. The ca. 60 kDa recombinant protein specifically converted farnesyl diphosphate to 9-epi-caryophyllene. LiCPS also produced a few monoterpenes when assayed with the monoterpene precursor geranyl diphosphate (GPP), but--unlike most monoterpene synthases--was not able to derive detectable amounts of any products from the cis isomer of GPP, neryl diphosphate. The LiCPS transcripts accumulated in developing L. x intermedia flowers and were highly enriched in glandular trichomes, but were not detected in leaves suggesting that the transcriptional expression of this gene is spatially and developmentally regulated.

  11. Molecular cloning and functional characterization of borneol dehydrogenase from the glandular trichomes of Lavandula x intermedia.

    Science.gov (United States)

    Sarker, Lukman S; Galata, Mariana; Demissie, Zerihun A; Mahmoud, Soheil S

    2012-12-15

    Several varieties of Lavandula x intermedia (lavandins) are cultivated for their essential oils (EOs) for use in cosmetic, hygiene and personal care products. These EOs are mainly constituted of monoterpenes including camphor, which contributes an off odor reducing the olfactory appeal of the oil. We have recently constructed a cDNA library from the glandular trichomes (the sites of EO synthesis) of L. x intermedia plants. Here, we describe the cloning of a borneol dehydrogenase cDNA (LiBDH) from this library. The 780 bp open reading frame of the cDNA encoded a 259 amino acid short chain alcohol dehydrogenase with a predicted molecular mass of ca. 27.5 kDa. The recombinant LiBDH was expressed in Escherichia coli, purified by Ni-NTA agarose affinity chromatography, and functionally characterized in vitro. The bacterially produced enzyme specifically converted borneol to camphor as the only product with K(m) and k(cat) values of 53 μM and 4.0 × 10(-4) s(-1), respectively. The LiBDH transcripts were specifically expressed in glandular trichomes of mature flowers indicating that like other Lavandula monoterpene synthases the expression of this gene is regulated in a tissue-specific manner. The cloning of LiBDH has far reaching implications in improving the quality of Lavandula EOs through metabolic engineering. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Células glandulares atípicas em esfregaços cervicovaginais: significância e aspectos atuais Atypical glandular cells in cervical smears: significance and current aspects

    Directory of Open Access Journals (Sweden)

    Adriana Bittencourt Campaner

    2007-02-01

    Full Text Available Células glandulares atípicas (AGC em esfregaços cervicovaginais são achados citológicos raros, porém de significado representativo. Sua incidência varia, na literatura, de 0,08% a 0,81%. O sistema Bethesda de 2001 classifica estas lesões glandulares como AGCs sem outras especificações, AGCs provavelmente neoplásicas, adenocarcinoma cervical in situ (AIS e adenocarcinoma invasivo. Das mulheres portadoras de AGC, grande parte não apresentará qualquer tipo de alteração histológica em avaliação subseqüente. Entretanto, em 17,4% a 62,2% dos casos serão encontradas lesões histológicas significativas, como neoplasias intra-epiteliais cervicais, AIS, neoplasias escamosas e glandulares, cervicais e endometriais, bem como neoplasias de outras localizações. O risco de doença significativa está relacionado à subdivisão de AGC encontrada. Em virtude da elevada probabilidade de anormalidades histológicas significativas em casos de AGC, a simples repetição citológica é insuficiente para o seguimento dessa condição. Esta atualização descreve a epidemiologia, a avaliação e a conduta das pacientes portadoras dessa anormalidade citológica.Atypical glandular cells (AGC on cervical smears are unusual but important cytologic diagnosis. The incidence of AGC ranges from 0.08% to 0.81 % of all cervical smears tests. The 2001 Bethesda System nomenclature classifies these glandular lesions as AGC not otherwise specified, AGC favor neoplasia, endocervical adenocarcinoma in situ (AIS and invasive adenocarcinoma. Of women with AGC smears, a great number will have no histologic abnormalities on further evaluation. However, 17.4% to 62.2% are found to have significant histologic lesions such as cervical intraepithelial neoplasia, AIS, squamous and glandular cancers from sites farther the cervix and endometrium. The risk of significant disease is related to the AGC subclassification that was found. Because of the high likelihood that AGC

  13. Tratamento da esquitossomose mansoni pela oxamniquine em dose única, pela via oral

    Directory of Open Access Journals (Sweden)

    Aluizio Prata

    1976-06-01

    Full Text Available A oxamniquine em cápsulas foi usada no tratamento de 132 doentes com esquistossomose mansoni crônica, sendo 129 com a forma hepato-intestinal e 3 com a forma hepato-esplênica. A dose foi de 10 mg por quilo de peso corporal em 34 pacientes, 12.5 mg em 35 e 15 mg em 63. A tolerância foi excelente em 43,2% dos tratados, boa em 48,5% e satisfatória em 8,3%. As queixas mais freqüentes foram tonturas e sonolência, que aparecem logo após a ingestão da droga e são fugazes. Os exames de laboratório mostraram em um ou outro paciente somente discreta retenção de bromosulfaleina, aumento de transaminase e da bilirrubina, insuficientes para caracterizar uma hepatoxicidade evidente. O seguimento dos pacientes se prolongou por mais de quatro meses e constou de pelo menos cinco exames de fezes pelo método de sedimentação. Todos os exames foram negativos em 20 (66,66% pacientes que tomaram 10 mg, em 13 (56,52% que tomaram 12.5 mg e em 41 (89,13% que tomaram 15 mg. Excluindo-se os menores de 16 anos subiu a 95% a negatividade entre os que foram tratados com 15 mg.Oxamniquine in capsules was used in the treatment of 132 patients with chronic Schistosoma mansoni infections. 129 having the hepato intestinal form and 3 the hepato splenic form. The dose was 10mg per kiio body weight in 34 patients, 12.5mg in 35 and 15mg ip 63. The tolerance was excellent in 43.2% of those treated, good in 48.5% and satisfactory in 8.3%. The most frequent complaints were dizziness and somnolence which appear soon after ingestion and was transitory. Laboratory investigations showed in a few patients bromosutphalein retention, raised transaminases or biiirubin but insufficient to constitute hepatoxicity. The follow-up of the patients continued for more than 4 months and consisted of five or more examinations by a sedimentation method. AH the examinations were negative in 20 (66.66% patients who took lOmg, in 13 (56.52% who took 12.5mg and in 41 (89.13% who took 15mg

  14. Genetic architecture of capitate glandular trichome density in florets of domesticated sunflower (Helianthus annuus L.)

    Science.gov (United States)

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. Capitate glandular trichomes can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resist...

  15. Preliminary characterization of dose in personnel of interventional radiology; Caracterizacao preliminar da dose em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil)

    2016-07-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  16. Os curiosos xenoimplantes glandulares do doutor Voronoff Dr. Voronoff's curious glandular xeno-implants

    Directory of Open Access Journals (Sweden)

    Ethel Mizrahy Cuperschmid

    2007-09-01

    Full Text Available O presente artigo trata da visita do médico Serge Voronoff ao Brasil durante as Jornadas Médicas de 1928 e a subseqüente demonstração de sua técnica de xenotransplante diante da classe médica. Recorreu-se a jornais da época para ilustrar a natureza do imaginário popular em torno da cirurgia controversa e de seus pretensos milagres para a preservação da saúde e a manutenção da vida. A iniciativa de Voronoff abriu espaço para que outros profissionais da medicina relatassem sua prática cirúrgica de xenotransplante e também levou à popularização do tema, como o demonstram marchinhas de carnaval e comentários picantes da imprensa, por exemplo. Uma análise baseada em parâmetros científicos atuais é apresentada com a sugestão do possível envolvimento dos xenotransplantes na epidemiologia do HIV.Dr. Serge Voronoff visited Brazil during the Jornadas Médicas of 1928, where he demonstrated his xenotransplantation technique to the local medical community. The present article uses newspaper clippings from that time to illustrate how this controversial surgery and Voronoff's alleged miraculous preservation of good health and longevity was viewed in the popular imagination. Voronoff's initiative paved the way for other health professionals to report on their surgical experiences with xenotransplantation and also popularized the topic, which became the subject of Carnival songs and sardonic jokes in the press. An analysis is offered, based on current scientific parameters, along with a suggestion concerning the possible involvement of xenotransplantation in HIV epidemiology.

  17. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  18. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  19. Micromorphology of glandular structures in Echium vulgare L. flowers

    Directory of Open Access Journals (Sweden)

    Elżbieta Weryszko-Chmielewska

    2012-12-01

    Full Text Available The micromorphology of selected elements of Echium vulgare L. flowers was investigated, with special attention to the structure of the nectaries and the stigma of the pistil as well as types of trichomes occurring on the surface of the calyx. The nectary had the shape of an uneven disc located around the lower region of the four-parted ovary of the pistil. The glandular cells formed a tier with a height of 330 μm and a radial width of 144 μm. Nectar was secreted onto the nectary surface through anomocytic stomata located at the level of other epidermal cells. Most of the stomata were open, with a different dimension of the pore. Their largest number was observed at the base of the nectary, and 462 stomata were noted on the whole surface of the nectary. The cuticle on the surface of the guard cells formed fine, circular striae. The subsidiary cells formed striated cuticular ornamentation, with the striae arranged radially in the direction of the stoma, whereas on the surface of other epidermal cells the striae formed an arrangement with different directions. The epidermis on the surface of the stigma formed regularly arranged papillae with a fan-shaped, expanded upper part which had corrugated outer walls, whereas the base of the cell formed a widened small column. The epidermis of the abaxial part of the calyx was covered by numerous non-glandular trichomes of different length which were made up of one or several cells. The glandular trichomes in the epidermis of the calyx grew with smaller density compared to the protective trichomes, and they were composed of a 1-2-celled stalk and a glandular head.

  20. Valdose program: methodologies for dose assessment in internal contamination, 1997 census; Programma valdose: metodologie di valutazione della dose da contaminazione interna, censimento 1997

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni, G. [ENEA, Centro Ricerche `Ezio Clementel`, Bologna (Italy). Dip. Ambiente

    1998-12-31

    Dose assessment in internal dosimetry needs computational and interpretative tools that allow carrying out, as a first step, an evaluation of intake on the base of bioassay measurements or WBC measurements, and as a second step, dose evaluation on the base of estimated intake. In the frame of the MIDIA Co-ordination (WBC operating in Italy), in the first months of 1997 a census on methodologies for dose evaluation in internal contamination has been proposed. A technical form has been sent to all the WBC Centres allowing an accurate description of modalities used in each centre. 9 out of 17 centres sent the answers to the technical form in time. In this paper all the forms filled in are reported. A careful comparative evaluation of the answers has been made both for routine monitoring and for special monitoring. The various radionuclides present in the Italian reality, calculation methodologies both for intake and dose, hypotheses adopted for date, path and modalities of contaminations are also presented. Proposals for conforming to the methodology in Italy after the introduction of the models following ICRP 60 publication that are the base of the Euratom 96/29 Directive are also discussed. [Italiano] La valutazione di dose in contaminazione interna necessita di strumenti interpretativi che permettano di effettuare in una prima la valutazione dell`intake sulla base delle misure dei campioni biologici o del corpo intero (WBC), ed in una seconda fase la valutazione della dose sulla base dell`intake. All`interno del coordinamento MIDIA dei WBC operanti in Italia e` stato proposto, nel primo trimestre del 1997, un censimento sulle metodologie di valutazione di dose da contaminazione interna. Ai diversi centri e` stato inviato una scheda tecnica che, mediante un particolareggiato schema di domande, aiutava i diversi centri nella esposizione delle modalita` di valutazione di dose che ogni centro segue. 9 au 17 centri WBC operanti al momemnto in Italia hanno inviato la

  1. Produção da bananeira nanica (1º ciclo em função da aplicação de doses de biofertilizantes líquidos

    Directory of Open Access Journals (Sweden)

    Juliara dos Santos Silva Araujo

    2014-05-01

    Full Text Available Objetivou-se com este trabalho, estudar os efeitos de 5 tipos e 10 doses de biofertilizantes na produção da bananeira Nanica (1º ciclo. O experimento foi conduzido, em condições de campo, no CCHA, pertencente a Universidade Estadual da Paraíba-UEPB, Campus Catolé do Rocha-PB. O delineamento experimental adotado foi o de blocos casualizados, com 50 tratamentos, no esquema fatorial 5 x 10, com quatro repetições, totalizando 200 parcelas experimentais. O valor do número de frutos por planta aumentou com o incremento da dose do biofertilizante B4 até um limite ótimo; o peso total de pencas por cacho aumentou linearmente com o incremento da dose de biofertilizante, atingindo o valor maior máximo na dose máxima; o peso médio de penca aumentou linearmente com o incremento da dose do biofertilizante B2, atingindo o maior valor na dose máxima; o peso médio do fruto e o peso do fruto médio aumentaram linearmente com o aumento da dose do biofertilizante B5, atingindo os maiores valores na dose máxima; a aplicação de (B5 proporcionou maior peso médio do fruto e peso do fruto médio.

  2. Avaliação do efeito da partição de comprimidos de furosemida sobre a uniformidade da dose

    Directory of Open Access Journals (Sweden)

    AMANDA APARECIDA DE ANDRADE FERREIRA

    2011-06-01

    Full Text Available Buscando avaliar a uniformidade da dose unitária de comprimidos submetidos ao procedimento de partição, este trabalho avaliou a dureza, friabilidade, variação de peso e uniformidade de conteúdo em quatro amostras de comprimidos de furosemida de 40 mg, obtidas de diferentes fornecedores. Todas as amostras estudadas atendiam às especificações oficiais antes de serem submetidas ao procedimento de partição; porém, após serem partidas, o teor de fármaco nas metades apresentou excessiva variação, mostrando que esse procedimento pode ser terapeuticamente desaconselhável. Palavras-chave: Partição de comprimidos. Uniformidade de dose. Comprimidos. Terapia oral. ABSTRACT Influence of tablet splitting on dose uniformity In order to assess the uniformity of the dose of active ingredient in the halves of tablets subjected to splitting, the hardness, friability, weight variability and uniformity of content were studied in four samples of 40 mg tablets of furosemide obtained on the Brazilian market, both whole and split into two parts. All the tablets complied with the official specifications before splitting, but, after this procedure, the drug content in the halves showed excessive variation, indicating that this procedure is inadvisable. Keywords: Tablet fractioning. Uniformity of dose. Tablets. oral therapy.

  3. Otimização agroeconômica da cenoura fertilizada com diferentes doses de jitirana

    Directory of Open Access Journals (Sweden)

    Francisco Bezerra Neto

    Full Text Available A utilização de espécies espontâneas do bioma Caatinga como adubo verde tem-se constituído opção importante na produção de hortaliças com o intuito de alcançar o equilíbrio entre aumento na produtividade das culturas e exploração do meio ambiente. O objetivo deste trabalho foi avaliar o uso de diferentes doses de jitirana como adubo verde no desempenho agroeconômico da cenoura em cultivo solteiro. O estudo foi conduzido na Fazenda Rafael Fernandes, distrito de Alagoinha, Estado do Rio Grande do Norte, no período de novembro de 2010 a fevereiro de 2011. O delineamento experimental foi de blocos ao acaso com quatro tratamentos repetidos quatro vezes. Os tratamentos consistiram das seguintes doses de jitirana: 7,5; 15; 22,5 e 30 t ha-1 em base seca. A cultivar de cenoura semeada foi a Brasília. As características avaliadas foram: altura de plantas, número de hastes por planta, massa seca da parte aérea e de raízes, produtividades comercial e total de raízes, produtividade classificada de raízes e os indicadores econômicos: renda bruta, renda líquida, taxa de retorno e índice de lucratividade. A otimização do desempenho agroeconômico da cenoura em cultivo solteiro é viabilizada com a incorporação de 13 t ha-1 de jitirana ao solo. O cultivo da cenoura é viável agroeconomicamente com o uso da jitirana como adubo verde.

  4. Optimization of the therapeutic dose of {sup 131}I for thyroid differentiated carcinoma; Otimizacao da dose terapeutica com {sup 131}I para carcinoma diferenciado da tiroide

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Fabiana Farias de

    2002-09-01

    I-131 thyroid cancer therapy is based on the strategy of concentrating radioactive iodine in the thyroid tissue, to completetly eliminate thyroid tissue and functioning thyroid cancer metastases remaining after thyroidectomy. In Brazil, fixed activities of {sup 131} I generally are given, sometimes either delivering insufficient activities to ablate all of the remnants, or unnecessarily high activities, with patients remaining in the hospital for some period of time. This investigation proposes a protocol of individualized planning of ablative doses, based on individual patients metabolisms and measured thyroid remnant masses. Simulated thyroid remnants were fabricated in various forms, volumes and activities, and optimum image acquisition parameters were determined using Single-Photon Emission Computed Tomography 9SPECT). Resultant images were evaluated, to determine the apparent volumes and the {sup 131} I concentrations. I-131 metabolism was studied in 9 patients who had undergone thyroidectomies. Their thyroid remnant masses were determined applying the same parameters used in SPECT simulation studies, and the optimum activity for their therapy was calculated and compared to the established fixed activity of 3.7 GBq (100 mCi), which would have normally been assigned. Background subtraction using the method of percent maximum counts, using a value of 67.5%, combined with scatter correction (triple energy window method), was shown to be optimum for SPECT quantification of volumes between 3-10 ml. Errors in the method were below 9% for sources with regular geometries and around 11% for sources with irregular geometries. In the patient studies, it was observed that 78% of patients could have received reduced activities of {sup 131} (from 0.8-3-2. GBq (20-87 nCi). In addition, 33% of these patients could have received low enough activities to have discharged from the hospital, using an individualized administration scheme. This could also have resulted in a dose

  5. Contribution of the height in the ambient dose equivalent; Contribuicao da altitude no equivalente de dose ambiente

    Energy Technology Data Exchange (ETDEWEB)

    de Campos, Vicente de P.; Manzoli, Jose E.; Alipio, Osvaldo C.; Carneiro, Janete C.G.; Rodrigues Junior, Orlando, E-mail: vpcampos@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The aim of this study is to evaluate the contribution of natural sources in the ambient dose equivalent. The evaluation of the levels of environmental radiation was performed using thermoluminescent dosimeters CaSO{sub 4} of doped C, which have high sensitivity and little fading. The dosimeters were placed in five locations at different altitudes, covering the period from three to nine years depending on their location. The results were grouped according to the use and occupation of land in the vicinity of the measurement point.

  6. Botulinum toxin for treatment of glandular hypersecretory disorders.

    LENUS (Irish Health Repository)

    Laing, T A

    2012-02-03

    SUMMARY: The use of botulinum toxin to treat disorders of the salivary glands is increasing in popularity in recent years. Recent reports of the use of botulinum toxin in glandular hypersecretion suggest overall favourable results with minimal side-effects. However, few randomised clinical trials means that data are limited with respect to candidate suitability, treatment dosages, frequency and duration of treatment. We report a selection of such cases from our own department managed with botulinum toxin and review the current data on use of the toxin to treat salivary gland disorders such as Frey\\'s syndrome, excessive salivation (sialorrhoea), focal and general hyperhidrosis, excessive lacrimation and chronic rhinitis.

  7. Optimization of dose in computerized radiology exams of the hands; Otimizacao da dose em exames de radiologia computadorizada de mao

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, Ana Luiza Menegatti; Alvarez, Matheus; Alves, Allan Felipe Fattori; Dela Rosa, Maria Eugenia; Miranda, Jose Ricardo de Arruda, E-mail: analuiza@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (IBB/UNESP), Botucatu, SP (Brazil). Inst. de Biofisica. Departamento de Fisica e Biofisica; Pina, Diana Rodrigues de; Ribeiro, Sergio Marrone [Universidade Estadual Paulista Julio de Mesquita Filho (FMB/UNESP), Botucatu, SP (Brazil). Fac. de Medicina. Dept. de Doencas Tropicais e Diagnostico por Imagem; Duarte, Sergio Barbosa [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fractures and dislocations of the hand are some of the most frequently encountered injuries of the musculoskeletal system traumas. To evaluate these lesions radiography is the investigation of choice, and is rarely needed the help of other images to establish the diagnosis and treatment. The image quality of the X-ray examination is therefore essential. In this study a homogeneous phantom hand was developed for use in the hand image optimization process. In this procedure were quantified for different tissue thicknesses which are an anthropomorphic hand phantom. To perform the classification and quantification of tissue was applied membership functions in histograms of CT scans. The same procedure was adopted for 30 retrospective examinations of patients in the Hospital of the Faculty of Medicine of Botucatu UNESP (HCFMB-UNESP). The homogeneous phantom built was used to calibrate the techniques used in clinical routine (RC). Such calibrated techniques were used to acquire images of anthropomorphic phantom. These images were analyzed by Visual Grading Method (VFA) by experienced radiologists in the area. The image with better grade in AGV and lower dose was chosen as the Gold Standard. The results showed concordance between the tissue thicknesses which constitute the anthropomorphic phantom and the sample evaluated patients, with variations between 12.63% and 6.48% for soft tissue and bone, respectively. The Gold Technical Standard compared with the technique normally used in the CR reduces dose charge 41.28% and 33.18% in the tube.

  8. Diagnóstico sorológico da brucelose bovina em animais adultos vacinados com dose reduzida da cepa 19 de Brucella abortus Serological diagnosis of bovine brucellosis in adult herd vaccinated with Brucella abortus strain 19 reduced dose

    Directory of Open Access Journals (Sweden)

    Gustavo Coelho Jardim

    2006-09-01

    Full Text Available Com o presente trabalho avaliou-se o uso de dose reduzida da vacina produzida com a amostra 19 de Brucella abortus, em rebanho adulto negativo para a enfermidade, por meio de técnicas de diagnóstico sorológico preconizadas pelo Programa Nacional de Controle e Erradicação da Brucelose e Tuberculose Animal e por um ensaio indireto de imunoadsorção enzimática (ELISA ID. A prova de fixação de complemento detectou 46,77% de positivos, o antígeno acidificado tamponado 67,74%, o 2-mercaptoetanol com soroaglutinação lenta 87,09% e o ELISA ID 100%. A dose reduzida interferiu no diagnóstico sorológico. Nenhuma das técnicas apresentou especificidade adequada para uso em rebanho nestas condições, até 3 meses após a vacinação.The study evaluated the use of a reduced dose of the Brucella abortus strain 19 vaccine, in an adult herd negative for the disease, by serological diagnostic techniques, advocated by the Brazilian Program for Animal Brucellosis and Tuberculosis Control and Eradication, and by an indirect ELISA. The complement fixation test detecteed 46.77% positives, the rose bengal test 67.74%, the mercaptoethanol with standard agglutination test 87.09% and the ELISA ID 100%. The reduced dose influenced the serological diagnosis. None of the techniques reached a suitable specificity for use in the herd under those conditions, up to 3 months after vaccination.

  9. Measurement of the radiation dose and assessment of the risk in mammography screening for early detection of cancer of the breast, in Israel

    International Nuclear Information System (INIS)

    Broisman, A.; Schlesinger, T.; Alfassi, Z. B.

    2011-01-01

    The mean glandular doses to samples of women attending for mammographic screening are measured routinely at screening centres in Israel. As at present, no detailed and systematic data have been collected regarding the average glandular dose in mammography screening procedures carried out in Israel for the last 20 y. Especially data are lacking related to the glandular dose (GD) involved in mammography with the new digital mammography systems. In this work, partial results of the measurements are presented to asses the radiation dose to the breast and to the glandular tissue within the Israeli national mammography programme updated to year 2009. (authors)

  10. Lodo de esgoto e sistema radicular da pupunheira Sewage sludge doses and the root system of peach palm

    Directory of Open Access Journals (Sweden)

    Fernando Vinicio Armas Vega

    2005-04-01

    Full Text Available Os efeitos do lodo de esgoto sobre o sistema radicular da pupunheira foram estudados em experimento em campo, em blocos casualizados, instalado em Ubatuba (SP, em julho 2001, na densidade de 5.000 plantas ha-1. As doses de lodo de esgoto fresco (79,7 % de umidade utilizadas foram de 0, 38, 76 e 152 t ha-1, equivalentes a 0, 100, 200 e 400 kg ha-1 de N. Os tratamentos foram aplicados no sulco de plantio, adicionando-se 15 g por planta de KCl como fonte de K. A análise do sistema radicular foi efetuada doze meses após, por meio de trado e de trincheiras e com o auxílio de fotos digitais. Detectou-se que o sistema radicular de pupunheiras com um ano de campo estava concentrado nas camadas superficiais (acima de 75 % nos primeiros 20 cm, assim como em distâncias de até 0,5 m da base da planta. O lodo de esgoto modificou positivamente a densidade do solo, alterando também favoravelmente a densidade das raízes. Houve aumento na biomassa radicular proporcional às doses de lodo de esgoto, existindo uma relação direta daquela com a fitomassa aérea. Doses de lodo equivalentes a 200 e 400 kg de N contribuíram para aprofundar o sistema radicular e proporcionaram maior quantidade relativa de raízes finas.The effects of sewage sludge doses on the root system of peach palm were studied in a field experiment, in randomized complete blocks, carried out in Ubatuba, state of São Paulo, Brazil. The trial was set up in July 2001, with a density of 5,000 plants ha-1. The sewage sludge doses (79.7 % water content were 0, 38, 76, and 152 t ha-1, which were equivalent to doses of 0, 100, 200, and 400 kg ha-1 of N. The treatments were applied in the planting furrow, and every plant was provided with K by a dose of 15 g potassium chloride. The root system was analyzed one year after planting using soil auger and digging of trenches and with the help of digital images. It was concluded that the root system of one-year old peach palm was concentrated in the

  11. Uso de diferentes doses de manipueira na cultura da alface em substituição à adubação mineral Use of different doses of cassava wastewater in lettuce crop in substitution of mineral fertilizer

    Directory of Open Access Journals (Sweden)

    Anamaria de S. Duarte

    2012-01-01

    Full Text Available Objetivou-se, neste trabalho, verificar o efeito ocasionado pelo uso de diferentes doses de manipueira nas características agronômicas da alface em substituição à adubação mineral. O referido estudo foi desenvolvido em uma área pertencente ao Departamento de Tecnologia Rural da Universidade Federal Rural de Pernambuco, Recife, PE, no período de maio a agosto de 2010. O experimento foi conduzido em ambiente protegido em delineamento inteiramente casualizado, com seis tratamentos compostos das seguintes doses: 0, 5, 15, 25, 45, 65 m³ ha-1 e cinco repetições. Utilizou-se a cultivar de alface Regina 2000, dispondo-se uma planta por vaso de 4 L. Foram avaliadas, em função das doses aplicadas, as seguintes características agronômicas da alface: área foliar, altura de planta, número de folhas, matéria fresca e matéria seca da alface. Ao final do experimento constatou-se que a dose de 45 m³ ha-1 foi a que propiciou maior ganho de altura de planta, área foliar e, consequentemente, também maior produção de matéria fresca e seca. Assim sendo, o uso da manipueira serviu como fonte de adubação para a cultura da alface, dependendo da dose aplicada.The main goal of this work was to evaluate the effect on agronomic characteristics of the lettuce when using different doses of cassava wastewater instead of mineral fertilizer. This study was conducted at the Departamento de Tecnologia Rural da Universidade Rural de Pernambuco, Recife, PE, from May to August 2010. The experiment was carried out under greenhouse conditions in a completely randomized blocks, with six treatments and five repetitions. Following doses were used: 0, 5, 15, 25, 45 and 65 m³ ha-1. The lettuce cultivar Regina 2000 was used (one plant per pot and leaf area, plant height, number of leaves, fresh leaf mass and dry leaf mass were evaluated for each dose of cassava wastewater. At the end of the experiment, the dose of 45 m³ ha-1 provided the best results by

  12. Evaluation of occupational exposure in intraoral radiography; Avaliacao da dose ocupacional em radiografia intraoral

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C., E-mail: miguel_cristianoch@yahoo.com.br, E-mail: saicla@utfpr.edu.br, E-mail: annarocha@yahoo.com, E-mail: walmor.godoi@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Federal do Parana (HC/UFPR), Curitiba, PR (Brazil). Hospital das Clinicas

    2014-07-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  13. DESENVOLVIMENTO INICIAL DA MAMONEIRA SOB DIFERENTES FONTES E DOSES DE MATÉRIA ORGÂNICA

    Directory of Open Access Journals (Sweden)

    Francisco de Assis de Oliveira

    2009-01-01

    Full Text Available The culture of the castor bean comes as a promising alternative for the producing of the semi-arid Northeasterner, mainly for to present characteristics as adaptation to the climatic conditions and to present in seeds they nourish chemistries of addition importance for production of Biodiesel, however, they are still scarce studies on techniques handling of this culture, mainly as the manuring This work driven with the objective of evaluating the initial development of the castor bean submitted to different sources and doses of organic matter. The used design was it entirely randomized in factorial outline 2 x 5, with three replications. The treatments were composed by the combination of two sources (manure bovine and manure ovine and five tenors of organic matter in the composition of the substratum (0, 10, 20, 30 and 40. The appraised growth indexes were: plant height, number of leaves, stem diameter and fitomassa of the aerial part. The castor bean answered the sources and the studied doses significantly, as well as the interaction among these factors. Answer was verified forms quadratic the doses of bovine and lineal manure to the doses of manure ovine. The largest development of the plants was verified with bovine manure, in close tenors of 30%.

  14. Breast Glandularity in Malaysian Women from a Full-Field Digital Mammography System

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung; Siti Selina Abdul Hamid; Juliana Mahamad Napiah

    2014-01-01

    This study is undertaken to estimate breast glandularity in Malaysian women from a Full-Field Digital mammography System. This study involved 223 women (Malay=100;Chinese=101 and Indian=22) underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia (IIUM Breast Centre) for the first quarter of year 2009. Those are women aged between 31 to 69 years old (median age, 49 years). Data on miliampere-seconds, kilo voltage and compressed breast thickness for each cranio caudal view are used to estimate breast glandularity for an individual breast. Breast glandularity is calculated using the fitted equation reported earlier. The difference in breast glandularity among ethnic groups was tested for significance using the nonparametric Kruskal-Wallis test. The average breast glandularity estimated in our study, using FFDM system is 52.94±27.63 %. No significant difference was seen in breast glandularity among the ethnic groups (p>0.05, Kruskan Wallis test). Breast glandularity decrease as age increases, up to 60 years old. (author)

  15. DOSES DE LODO DE ESGOTO SOBRE O DESENVOLVIMENTO DA GRAMA BERMUDA (Cynodon dactylon)

    OpenAIRE

    NOBILE, Fabio Olivieri de; NUNES, Hugo Dias; NEVES, Jéssica Caroline

    2014-01-01

    Population growth occurred rapidly, resulting in cities with poor infrastructure on the sanitation sector. So, there was the introduction of sanitary treatment, causing difficulty in choosing alternatives for the proper disposal of sewage sludge, rich in essential nutrients for the plants. The experiment was conducted to determine the best dose of sewage sludge to Grass Cynodon dactylon. It was conducted in greenhouse in the University Center of Educational Foundation of Barretos-SP. The expe...

  16. Análise da dose do laser de baixa potência em equipamentos nacionais Analysis of low-level laser therapy doses in Brazilian equipment

    Directory of Open Access Journals (Sweden)

    TY Fukuda

    2008-02-01

    Full Text Available CONTEXTUALIZAÇÃO: A laserterapia de baixa potência vem sendo cada vez mais utilizada, e o crescente interesse por seus efeitos relaciona-se com a grande quantidade de publicações científicas. Muitos terapeutas e pesquisadores têm-se baseado na definição da dose do laser pela densidade energética (deltaE; porém, a grande variedade de equipamentos de laser pode levar a diferença nos resultados terapêuticos encontrados, por fornecerem parâmetros que variam de acordo com o fabricante. OBJETIVO: Analisar a energia final transmitida ao tecido ao aplicar-se a mesma deltaE em equipamentos de diferentes marcas nacionais. MATERIAIS E MÉTODOS: Foram avaliados sete equipamentos nacionais, com potência média (Pm diferentes, e foram realizadas simulações aplicando deltaE de 1J/cm² em cada aparelho, para avaliar possíveis diferenças na energia final. RESULTADOS: A mesmadeltaE aplicada em diferentes aparelhos nacionais forneceu energia final que variou entre 10 e 90mJ. Esta variação na energia deveu-se principalmente a diferenças na Pm, sendo encontrados valores entre 5,4 e 75mW. CONCLUSÃO: Esta variabilidade na energia final, que é transmitida ao tecido, indica que a deltaE parece não ser o parâmetro que melhor descreve a dose a ser utilizada. É preciso mencionar não só a deltaE, mas também a energia final, para que se possa estabelecer a dose para obtenção do melhor resultado terapêutico.INTRODUCTION: Low-level laser therapy is becoming more popular and there is a growing interest in its effects, as reflected in the increased number of articles published about the subject. Many therapists and researchers have used a laser dose definition based on energy density (deltaE. However, the variety of laser equipments may lead to differences in the therapeutic results found, since the parameters supplied by these equipments vary according to the manufacturer. OBJECTIVE: To analyze the final energy transmitted to the tissue when

  17. Telomerase reverse transcriptase promoter mutations in glandular lesions of the urinary bladder.

    Science.gov (United States)

    Vail, Eric; Zheng, Xiaoyong; Zhou, Ming; Yang, Ximing; Fallon, John T; Epstein, Jonathan I; Zhong, Minghao

    2015-10-01

    Glandular lesions of the urinary bladder include a broad spectrum of entities ranging from completely benign to primary and secondary malignancies. The accurate diagnosis of these lesions is both important and challenging. Recently, studies suggest that telomerase reverse transcriptase (TERT) promoter mutations could be a biomarker for urothelial carcinoma (UC). We hypothesized that these mutations can distinguish UC with glandular differentiation from nephrogenic adenoma, primary adenocarcinoma of the urinary bladder (PAUB), or secondary malignancies. Twenty-five cases of benign glandular lesions (including nephrogenic adenoma); 29 cases of UC with glandular differentiation; 10 cases of PAUB; and 10 cases each of metastatic colon cancer, prostatic carcinoma, and carcinoma from Mullerian origin were collected. Slides were reviewed and selected to make sure the lesion was at least 10% to 20% of all tissue. Macrodissection was performed in some of cases, and genomic DNA was extracted from the tissue. Telomerase reverse transcriptase promoter mutations were determined by standard polymerase chain reaction sequencing. Twenty-one cases (72%) of UC with glandular differentiation were positive for TERT promoter mutations. However, none of the remaining cases (total 65 cases of benign lesions, PAUB, and metastatic carcinomas) was positive for TERT promoter mutation. Telomerase reverse transcriptase promoter mutations were highly associated with UC including UC with glandular differentiation but not other glandular lesions of bladder. Therefore, in conjunction with morphologic features, Immunohistochemistry stain profile, and clinical information, TERT promoter mutations could distinguish UC with glandular differentiation from other bladder glandular lesions. In addition, lack of TERT promoter mutations in primary adenocarcinoma of bladder suggests that this entity may have different origin or carcinogenesis from those of UC. Published by Elsevier Inc.

  18. Cocleotoxicidade da gentamicina por doses habituais para neonatos - estudo funcional A functional study on gentamicin-related cochleotoxicity in its conventional dose in newborns

    Directory of Open Access Journals (Sweden)

    Carla Luiza Baggio

    2010-02-01

    Full Text Available A identificação precoce das alterações auditivas possibilita a intervenção ainda no "período crítico" e ideal de estimulação da linguagem e da audição. A ototoxicidade infantil é um tema bastante controverso. Têm sido relatadas percentagens variáveis de casos de ototoxicidade em crianças com vários antibióticos aminoglicosídeos. Os principais grupos pediátricos que recebem antibióticos aminoglicosídeos são recém-nascidos com infecções graves na UTI neonatal. OBJETIVOS: Verificar o aspecto funcional das células ciliadas externas da cóclea a esquemas terapêuticos utilizados para o tratamento de infecções no período neonatal. FORMA DE ESTUDO: Experimental. MATERIAL E MÉTODO: Foram estudadas 26 cobaias albinas, através das emissões otoacústicas por produto de distorção, prévia e posteriormente a aplicação de gentamicina. RESULTADOS: Em todas as avaliações, o estado funcional das células ciliadas externas, estudadas pelas emissões otoacústicas por produto de distorção, mostraram-se preservadas. CONCLUSÃO: Neste experimento não foram observadas alterações no funcionamento das células ciliadas externas de cobaias albinas sob tratamento com gentamicina nas doses de 4 mg/Kg/dia e 2,5 mg/Kg/dia a cada 12 horas, por 10 e 14 dias.The early identification of hearing impairment allows for an intervention still in the "critical" and ideal period of hearing and language stimulation. Pediatric ototoxicity is a very controversial topic. There have been variable percentages of ototoxicity cases in children with different aminoglycosides antibiotics. The main pediatric groups whom receive aminoglycosides are newborns with severe infections on the neonatal ICU. AIM: to check the functional aspect of the cochlear external hair cells and treatment regimens used to treat infections during the neonatal period. STUDY DESIGN: Experimental. Materials and Methods: we studied 26 albino guinea pigs, through distortion

  19. Diagnostic and therapeutic dilemma associated with atypical glandular cells on liquid-based cervical cytology.

    LENUS (Irish Health Repository)

    Chummun, K

    2012-12-01

    In 2008, the management of women in Ireland with atypical glandular cells changed to immediate referral to colposcopy. The optimal management of these women is unclear. A balance between the detection of occult disease and overtreatment is required.

  20. Morfoanatomia, tricomas glandulares e fitoquímica de Lomatozona artemisiifolia Baker (ASTERACEAE - EUPATORIEAE) - uma planta endêmica do Cerrado de Goiás

    OpenAIRE

    Trindade, Luma Mota Palmeira

    2013-01-01

    Morfoanatomia, tricomas glandulares e fitoquímica de Lomatozona artemisiifolia Baker (Asteraceae - Eupatorieae) – Uma planta endêmica do cerrado de Goiás - A família Asteraceae é amplamente distribuída, possuindo 24.000 espécies e 1.600 a 1700 gêneros, constituindo uma das maiores famílias de fanerógamas. No Cerrado, dentre as fanerógamas, é a segunda maior família em quantidade de espécies. Dentre as inúmeras espécies de Asteraceae está presente Lomatozona artemisiifolia Baker, pertence à tr...

  1. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives; Primo interconfronto italiano sulle metodiche di valutazione di dose da contaminazione interna: risultati e prospettive

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1998-07-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated. [Italian] Vengono riportati i risultati delle valutazioni di Intake e di equivalente di dose nei centri MIDIA (coordinamento dei WBC operanti in Italia) per effettuare un interconfronto sui metodi di valutazione di dose da contaminazione interna utilizzando casi di studio reperiti in ambiente europeo. Vengono indicate le prospettive per la valutazione della qualita' della stima di dose in dosimetria interna.

  2. Mineral nutrient uptake from prey and glandular phosphatase activity as dual test of carnivory in semidesert plants with glandular leaves suspected of carnivory

    Czech Academy of Sciences Publication Activity Database

    Plachno, B.J.; Adamec, Lubomír; Huet, H.

    2009-01-01

    Roč. 104, č. 4 (2009), s. 649-654 ISSN 0305-7364 Institutional research plan: CEZ:AV0Z60050516 Keywords : mineral nutrient uptake * phosphatases * glandular leaves Subject RIV: EF - Botanics Impact factor: 3.501, year: 2009

  3. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  4. Estudo dos efeitos de diferentes tipos e doses de biofertilizantes na produção e na qualidade da produção da videira “Isabel”

    Directory of Open Access Journals (Sweden)

    Atos Tavares Gomes

    2014-06-01

    Full Text Available Objetivou-se, com este trabalho, avaliar a produção e as características químicas dos frutos da videira ‘Isabel’ sob aplicação de biofertilizantes líquidos. O experimento foi realizado, em condições de campo, no Centro de Ciências Humanas e Agrárias da Universidade Estadual da Paraíba, localizado no município de Catolé do Rocha/PB. Estudou­-se 5 tipos de biofertilizante  e 8 doses (0; 0,35; 0,7; 1,05; 1,4; 1,75; 2,1e 2,45 L/aplicação na produção e qualidade da produção da videira “Isabel”. O delineamento experimental adotado foi de blocos casualizados com 40 tratamentos no esquema fatorial 5 x 8 com quatro repetições totalizando 160 plantas experimentais. O número de cachos por plantas aumentou com o incremento das doses de biofertilizantes B1, B2 e B5  até os limites ótimos de 1,28. 1,20 e 1,50 L/aplicação, havendo redução a partir desses valores; O número de cachos por planta diminuiu com o aumento das doses de biofertilizantes B1, B2 e B5 acima dos limites ótimos de biofertilizantes; número de cachos por plantas aumentou de forma linear com o incremento das doses de biofertilizantes B3 e B4, otimizando ao máximo com a dose de 2,45 L/aplicação; Os tipos e as doses de biofertilizantes não afetaram de forma significativa os sólidos solúveis totais (ºBrix, a acidez total titulável e a relação ºBrix/acidez total do fruto da videira Isabel. 

  5. EFEITO DE FONTES E DOSES DE NITROGÊNIO NA REAÇÃO DA CULTIVAR DE TRIGO BR 14 À Septoria nodorum

    Directory of Open Access Journals (Sweden)

    Eduardo Dânia Ugalde

    1993-04-01

    Full Text Available O experimento foi conduzido em casa de vegetação da UFSM no período de maio a outubro de 1989. Três plantas de trigo, cultivar BR 14, foram cultivadas em cada vaso (6 litros com Solo Podzólico Vermelho Amarelo (Unidade de Mapeamento São Pedro, com 70% da capacidade de campo, constituindo a unidade experimental. O delineamento experimental foi inteiramente casualizado, sendo que os tratamentos foram fontes e doses de N, e inoculação das plantas com Septoria nodorum, constituindo um trifatorial com três repetições. As fontes de nitrogênio utilizadas foram uréia e salitre do Chile nas doses de 30, 60, 90 e 120kg/ha de N, sendo parte aplicado na semeadura (30% e o restante (70% no estádio 2 (início do afilhamento da escala proposta por LARGE (1956. Os tratamentos que não foram inoculados com Septoria nodorum apresentaram maior percentagem de N no tecido, o que parece não ter sido afetado tanto com relação a fonte de nitrogênio nem quanto a dose utilizada. O teor de matéria seca, sendo consideradas plantas inoculadas e não inoculadas, não diferiu tanto para fontes como para doses de nitrogênio (kg/ha. A severidade da doença foi maior em plantas que receberam maiores doses de adubação nitrogenada.

  6. A calibration approach to glandular tissue composition estimation in digital mammography

    International Nuclear Information System (INIS)

    Kaufhold, J.; Thomas, J.A.; Eberhard, J.W.; Galbo, C.E.; Trotter, D.E. Gonzalez

    2002-01-01

    The healthy breast is almost entirely composed of a mixture of fatty, epithelial, and stromal tissues which can be grouped into two distinctly attenuating tissue types: fatty and glandular. Further, the amount of glandular tissue is linked to breast cancer risk, so an objective quantitative analysis of glandular tissue can aid in risk estimation. Highnam and Brady have measured glandular tissue composition objectively. However, they argue that their work should only be used for 'relative' tissue measurements unless a careful calibration has been performed. In this work, we perform such a 'careful calibration' on a digital mammography system and use it to estimate breast tissue composition of patient breasts. We imaged 0%, 50%, and 100% glandular-equivalent phantoms of varying thicknesses for a number of clinically relevant x-ray techniques on a digital mammography system. From these images, we extracted mean signal and noise levels and computed calibration curves that can be used for quantitative tissue composition estimation. In this way, we calculate the percent glandular composition of a patient breast on a pixelwise basis. This tissue composition estimation method was applied to 23 digital mammograms. We estimated the quantitative impact of different error sources on the estimates of tissue composition. These error sources include compressed breast height estimation error, residual scattered radiation, quantum noise, and beam hardening. Errors in the compressed breast height estimate contribute the most error in tissue composition--on the order of ±7% for a 4 cm compressed breast height. The spatially varying scattered radiation will contribute quantitatively less error overall, but may be significant in regions near the skinline. It is calculated that for a 4 cm compressed breast height, a residual scatter signal error is mitigated by approximately sixfold in the composition estimate. The error in composition due to the quantum noise, which is the limiting

  7. Higher glandular trichome density in tomato leaflets and repellence to spider mites

    International Nuclear Information System (INIS)

    Maluf, Wilson Roberto; Inoue, Irene Fumi; Ferreira, Raphael de Paula Duarte; Gomes, Luiz Antonio Augusto; Castro, Evaristo Mauro de; Cardoso, Maria das Gracas

    2007-01-01

    The objective of this work was to evaluate the feasibility of selection for higher glandular trichome densities, as an indirect criterion of selection for increasing repellence to spider mites Tetranychus urticae, in tomato populations derived from an interspecific cross between Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Trichome densities were evaluated in 19 genotypes, including 12 from advanced backcross populations, derived from the original cross L. esculentum x L. hirsutum var. glabratum PI 134417. Counts were made both on the adaxial and abaxial leaf surfaces, and trichomes were classified into glandular types IV and VI, other glandular types (types I+VII), and nonglandular types. Mite repellence was measured by distances walked by mites onto the tomato leaf surface after 20, 40 and 60 min. Spider mite repellence biotests indicated that higher densities of glandular trichomes (especially type VI) decreased the distances walked by the mites onto the tomato leaf surface. Selection of plants with higher densities of glandular trichomes can be an efficient criterion to obtain tomato genotypes with higher resistance (repellence) to spider mites. (author)

  8. Avaliação da produção e qualidade de frutos de melancia sob diferentes doses de potássio em cobertura

    Directory of Open Access Journals (Sweden)

    Joel Carlos Alves Rodrigues

    2016-12-01

    Full Text Available O potássio desempenha várias funções na bioquímica e fisiologia das plantas, como nos processos de fotossíntese, transporte e armazenamento de assimilados. O objetivo do trabalho foi avaliar a produção e qualidade da melancia cv. ‘Crimson Select Plus’ em função de doses de potássio como cobertura. O delineamento experimental utilizado foi o de blocos ao acaso, com cinco tratamentos, quatro repetições e 20 plantas por parcela. Os tratamentos consistiram de cinco doses de potássio (0, 60, 120, 180 e 240 kg ha-1. A fonte de potássio utilizada foi o cloreto de potássio (60% de K2O, aplicado de forma parcelada em cobertura. Foram realizadas avaliações de produção e qualidade de frutos: diâmetro do fruto - DF (cm, comprimento de fruto - CF (cm, massa fresca - MF e seca do fruto - MS (kg fruto-1, espessura da polpa - EP (cm, espessura casca - EC (cm e produtividade – PRODU (t ha-1. Para avaliação de qualidade, foram realizadas as análises de sólidos solúveis - SS (ºbrix, pH, acidez titulável - AT e índice de maturação - IM (SS/AT. A espessura de casca, pH, acidez titulável e índice  de maturação não foi alterada pelas doses de potássio. A dose que apresentou melhores resultados para a cultura da melancia da cultivar “Crimson Select Plus” em cobertura foi de 209,39 kg de K2O ha-1

  9. Influência da dependência energética de dosímetros termoluminescentes na medida da dose na entrada da pele em procedimentos radiográficos Influence of thermoluminescent dosimeters energy dependence on the measurement of entrance skin dose in radiographic procedures

    Directory of Open Access Journals (Sweden)

    Mércia Liane de Oliveira

    2010-04-01

    Full Text Available OBJETIVO: O objetivo do presente trabalho foi avaliar a influência da dependência energética de materiais termoluminescentes na determinação da dose na entrada da pele de pacientes submetidos a exames radiográficos (radiologia geral, mamografia e radiologia odontológica. MATERIAIS E MÉTODOS: Três diferentes materiais termoluminescentes foram utilizados: LiF:Mg,Ti, LiF:Mg,Cu,P e CaSO4:Dy. Estes materiais foram expostos a fontes padronizadas de radiação X e gama, e a feixes clínicos de raios X. RESULTADOS: As curvas de calibração e de dependência energética foram obtidas. Todos os materiais apresentaram resposta linear em função do kerma no ar. Com relação à dependência energética, as amostras de CaSO4:Dy e LiF:Mg,Ti mostraram maior variação da resposta termoluminescente em função da energia efetiva do feixe de radiação. CONCLUSÃO: Os materiais testados mostraram desempenho adequado para a detecção da radiação X em feixes padronizados e clínicos. Embora as amostras de CaSO4:Dy e LiF:Mg,Ti apresentem dependência energética significativa no intervalo de energia considerado, este materiais podem ser utilizados para medição da dose de entrada na pele se fatores de correção apropriados forem utilizados.OBJECTIVE: This study was aimed at evaluating the influence of the energy dependence of thermoluminescent materials on the determination of entrance skin dose in patients submitted to conventional radiographic studies (general radiology, mammography and dental radiology. MATERIALS AND METHODS: Three different thermoluminescent materials were utilized: LiF:Mg,Ti, LiF:Mg,Cu,P and CaSO4:Dy. These materials were exposed to standardized sources of X and gamma radiation and clinical X-ray beams. RESULTS: Calibration and energy dependence curves were obtained. All the materials showed a linear response as a function of the air kerma. As far as energy dependence is concerned, the CaSO4:Dy and LiF:Mg,Ti samples showed the

  10. Cadmium induced changes in subcellular glutathione contents within glandular trichomes of Cucurbita pepo L.

    Science.gov (United States)

    Kolb, Dagmar; Müller, Maria; Zellnig, Günther; Zechmann, Bernd

    2010-07-01

    Plants cope with cadmium (Cd) stress by complexation with phytochelatins (Pc), metallothioneins and glutathione and sequestration within vacuoles. Especially glutathione was found to play a major role in Cd detoxification as Cd shows a high binding affinity towards thiols and as glutathione is a precursor for Pc synthesis. In the present study, we have used an immunohistochemical approach combined with computer-supported transmission electron microscopy in order to measure changes in the subcellular distribution of glutathione during Cd-stress in mesophyll cells and cells of different glandular trichomes (long and short stalked) of Cucurbita pepo L. subsp. pepo var. styriaca GREB: . Even though no ultrastructural alterations were observed in leaf and glandular trichome cells after the treatment of plants with 50 microM cadmium chloride (CdCl(2)) for 48 h, all cells showed a large decrease in glutathione contents. The strongest decrease was found in nuclei and the cytosol (up to 76%) in glandular trichomes which are considered as a major side of Cd accumulation in leaves. The ratio of glutathione between the cytosol and nuclei and the other cell compartments was strongly decreased only in glandular trichomes (more than 50%) indicating that glutathione in these two cell compartments is especially important for the detoxification of Cd in glandular trichomes. Additionally, these data indicate that large amounts of Cd are withdrawn from nuclei during Cd exposure. The present study gives a detailed insight into the compartment-specific importance of glutathione during Cd exposure in mesophyll cells and glandular trichomes of C. pepo L. plants.

  11. Dose estimation in CT exams of the abdomen based on values of DLP; Estimativa da dose em exames de tomografia de abdome com base nos valores de DLP

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F.; Medeiros, R.B.; Salvadori, P.S.; Costa, D.M.C; D' lppolito, G., E-mail: kikuticf@gmail.com, E-mail: rbitelli2011@gmail.com [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Coordenadoria de Fisica e Higiene das Radiacoes. Departamento de Diagnostico por Imagem

    2013-10-01

    One of the challenges of multidetector computerized tomography is to minimize the risk of ionizing radiation using optimized protocols since higher doses are necessary to obtain high image quality. It was also noted that, due to the geometry in image acquisition using MDCT becomes necessary to estimate dose values consistent with the hypothesis clinically and with the specificities of the tomographic equipment. The aim of this study was to estimate the doses in abdomen exams from the data recorded on the MDCT console and dimensions obtained from DICOM images of patients undergoing different clinical protocols. Were collected, from the image DICOM of 101 exams, values of the dose length product (DLP) provided by Philips Health Care - Brilliance 64 equipment console, in order to relate them with the dose values obtained by means of thermoluminescent dosimeters ( TLD ) of CasSo{sub 4}:Mn placed on the surface of a cylindrical simulator abdomen acrylic manufactured under the technical - operational conditions for a typical abdomen exam. From the data obtained, it was possible to find a factor of 1.16 ( 5 % ) indicating that the DLP values Brilliance 64 console underestimate the doses and this should be used with correction factor to estimate the total dose of the patient. (author)

  12. Avaliação da atividade "in vivo" da fosfatase ácida e do crescimento de progênies de pupunheira cultivadas em duas doses de nitrogênio e fósforo

    Directory of Open Access Journals (Sweden)

    M. L. A. Bovi

    1998-09-01

    Full Text Available O presente trabalho, realizado em janeiro de 1995, visou avaliar a atividade da enzima fosfatase ácida em folhas de quatro progênies de pupunheira (Bactris gasipaes Kunth, cultivadas em duas doses de nitrogênio e duas de fósforo. Para tanto, utilizou-se a porção média da segunda folha mais jovem de perfilhos de palmeiras com quatro anos de idade. As plantas analisadas representam parcelas submetidas a duas doses de nitrogênio (N1 = 0, N2 = 400 kg ha-1 ano-1 de N e duas doses de fósforo (P1 = 0, P2 = 200 kg ha-1 ano-1 de P2O5. A dose de potássio foi 200 kg ha-1 ano-1 de K2O. Análises dos elementos no solo e nas folhas foram efetuadas e correlações foram estimadas entre as características avaliadas e o crescimento e a produção de palmito dos quatro tratamentos. Foram observados valores médios de atividade da fosfatase ácida de 8,35; 4,58; 10,84, e 11,05 µmol h-1 g-1, para os tratamentos N2P2, N2P1, N1P2 e N1P1, respectivamente. Houve diferenças significativas de atividade entre doses de nitrogênio (10,95 e 6,47 µmol h-1 g-1, para N1 e N2, respectivamente e entre progênies (variando de 6,18 (G3 a 10,10 (G1 µmol h-1 g-1, indicando que esses dois fatores devem ser levados em conta em estudos dessa natureza. A atividade da fosfatase ácida apresentou correlação negativa com as características que avaliam o crescimento (biomassa aérea e radicular e a produção de palmito (peso e diâmetro das plantas estudadas, não se correlacionando com os teores de fósforo no solo ou no tecido foliar.

  13. Doses de fósforo e potássio no desenvolvimento da cultura de Crambe abyssinica

    Directory of Open Access Journals (Sweden)

    Lucia Helena Garófalo Chaves

    2016-04-01

    Full Text Available A cultura do crambe (Crambe abyssinica é uma alternativa para produção de biodisel recebendo este enfoque por sua rusticidade, precocidade, alto teor de óleo e adaptabilidade. Os nutrientes minerais possuem funções essenciais e específicas no metabolismo das plantas. A aplicação de fertilizantes minerais é feita para repor sua perda, pois a cada ciclo as plantas extraem nutrientes dos solos. O manejo adequado do uso de fertilizantes no cultivo do crambe é pouco conhecido, não havendo recomendações específicas para a adubação. Portanto, objetivou-se estudar os efeitos da adubação mineral relativa aos elementos fósforo e potássio, no crescimento e na produção do crambe. O experimento foi instalado em casa de vegetação, com delineamento inteiramente casualizado em esquema fatorial 4 x 4 + 1, com três repetições, totalizando 51 unidades experimentais. As doses de fósforo e potássio utilizadas foram 50; 75; 100 e 125 kg ha-1. Aos 60 dias após o semeio (DAS foram analisadas altura das plantas, diâmetro caulinar e número de ramificações. As plantas foram colhidas em fase de maturação aos 90 DAS, quando foram avaliadas a massa seca total das plantas, número de grãos por planta e massa de mil grãos. O crescimento e a produção do crambe, nestas condições, foram pouco influenciados pela aplicação de fósforo e potássio, provavelmente, porque a cultura foi prejudicada pela falta de adubação nitrogenada.Phosphorus and potassium doses in the development of Crambe abyssinica  cultureAbstract: Mineral nutrients have essential and specific roles in plant metabolism. The application of mineral fertilizers is made to replenish its loss, for every cycle of the plant extract soil nutrients. The crambe culture is an alternative for the production of biodiesel getting this approach for its rusticity, precocity, high oil content and adaptability. Proper management of fertilizer use in crambe cultivation is little known

  14. Produção da banana nanicão (musa sp. em função de tipos e doses de biofertilizantes

    Directory of Open Access Journals (Sweden)

    Fábio Itano dos S. Alves

    2014-04-01

    Full Text Available  O uso de biofertilizantes na fruticultura vem sendo estudado em diferentes regiões do Brasil, por serem consideradas fontes de nutrientes para as culturas de fácil acesso e de baixo custo. O trabalho teve como objetivo avaliar o crescimento vegetativo da bananeira (Musa sp. 'Nanica' submetida à aplicação via radicular de diferentes tipos e dosagens de biofertilizantes. O experimento foi conduzido, em condições de campo no Centro de Ciências Humanas e Agrárias (CCHA da Universidade Estadual da Paraíba (UEPB, Campus Catolé do Rocha. O delineamento experimental foi de blocos casualizados no esquema fatorial 5 x 10, sendo 5 tipos de biofertilizantes (B1 = Esterco bovino (EB; B2 = EB+ farinha de rocha (FR; B3 = EB + FR+ leguminosa (L; B4 = EB+FR+ cinza de madeira (C; e B5 = EB+FR +L+C e 10 doses (0; 0,3; 0,6; 0,9; 1,2; 1,5; 1,8; 2,1; 2,4 e 2,7 L planta-1 aplicação-1 com quatro repetições.Foramavaliado duranteo 1º e o 2º ciclodacultura, a altura da planta, o diâmetro do caule, o número de folhas ea área foliar unitária e total. Para as variáveis estudadas as dosagens de biofertilizantes não apresentaram efeitos significativos, porém os tipos de biofertilizantes foram significativos colaborando ao aumento da área foliar da planta.

  15. Committed effective dose determination in cereal flours by gamma-ray spectrometry; Determinacao das doses efetivas por ingestao de farinhas de cereais atraves da espectrometria de raios gama

    Energy Technology Data Exchange (ETDEWEB)

    Scheibel, Viviane

    2006-07-01

    The health impact from radionuclides ingestion of foodstuffs was evaluated by the committed effective doses determined in commercial samples of South-Brazilian cereal flours (soy, wheat, corn, manioc, rye, oat, barley and rice flour). The radioactivity traces of {sup 228}Th, {sup 228}Ra, {sup 226}Ra, {sup 40}K, {sup 7}Be and {sup 137}Cs were measured by gamma-ray spectrometry employing a 66% relative efficiency HPGe detector. The energy resolution for the 1332.46 keV line of {sup 60}Co was 2.03 keV. The committed effective doses were calculated with the activities analyzed in the present flour samples, the foodstuff rates of consumption (Brazilian Institute of Geography and Statistics) and the ingestion dose coefficients (International Commission of Radiological Protection). The reliability median activities were verified with {chi}{sup 2} tests, assuring the fittings quality. The highest concentration levels of {sup 228}Th and {sup 40}K were 3.5 {+-} 0.4 and 1469 {+-} 17 Bq.kg{sup -1} for soy flour, respectively, with 95% of confidence level. The lower limit of detection for {sup 137}Cs ranged from 0.04 to 0.4 Bq.kg{sup -1}. The highest committed effective dose was 0.36 {mu}Sv.y{sup -1} for {sup 228}Ra in manioc flour (adults). All committed effective doses determined at the present work were lower than the UNSCEAR limits of 140 {mu}Sv.y{sup -1} and much lower than the ICRP (1991) limits of 1 mSv.y{sup -1}, for general public. There are few literature references for natural and artificial radionuclides in foodstuffs and mainly for committed effective doses. This work brings the barley flour data, which is not present at the literature and {sup 7}Be data which is not encountered in foodstuffs at the literature, besides all the other flours data information about activities and committed effective doses. (author)

  16. Phenylpropanoid biosynthesis in leaves and glandular trichomes of basil (Ocimum basilicum L.).

    Science.gov (United States)

    Deschamps, Cícero; Simon, James E

    2010-01-01

    Basil (Ocimum basilicum L.) essential oil phenylpropenes are synthesized and accumulate in peltate glandular trichomes and their content and composition depend on plant developmental stage. Studies on gene expression and enzymatic activity indicate that the phenylpropene biosynthetic genes are developmentally regulated. In this study, the methylchavicol accumulation in basil leaves and the enzyme activities and gene expression of both chavicol O-methyltransferase (CVOMT) and eugenol O-methyltransferase (EOMT) were investigated in all leaves at four plant developmental stages. Methylchavicol accumulation decreased over time as leaves matured. There was a significant correlation between methylchavicol accumulation and CVOMT (r(2) = 0.88) enzyme activity, suggesting that the levels of biosynthetic enzymes control the essential oil content. CVOMT and EOMT transcript expression levels, which decreased with leaf age, followed the same pattern in both whole leaves and isolated glandular trichomes, providing evidence that CVOMT transcript levels are developmentally regulated in basil glandular trichomes themselves and that differences in CVOMT expression observed in whole leaves are not solely the result of differences in glandular trichome density.

  17. Honey bee males and queens use glandular secretions to enhance sperm viability before and after storage

    DEFF Research Database (Denmark)

    Den Boer, Susanne Petronella A; Boomsma, Jacobus Jan; Baer, Boris

    2009-01-01

    Internal fertilization requires live sperm to be transferred from male to female before egg fertilization. Both males and females assist the insemination process by providing sperm with glandular secretions, which have been inferred to contain subsets of proteins that maintain sperm viability. He...

  18. Severe glandular tularemia in a patient treated with anti-tumour necrosis factor for psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Ruxandra Calin

    2017-07-01

    Full Text Available A case of severe glandular tularemia in a patient receiving anti-tumour necrosis factor (TNF therapy is reported here. The patient required prolonged treatment with doxycycline–ciprofloxacin due to early relapse after ciprofloxacin was stopped. Tularemia may have a more severe course in patients receiving anti-TNF. This may thus be an indication for more aggressive treatment.

  19. A Stochastic Polygons Model for Glandular Structures in Colon Histology Images.

    Science.gov (United States)

    Sirinukunwattana, Korsuk; Snead, David R J; Rajpoot, Nasir M

    2015-11-01

    In this paper, we present a stochastic model for glandular structures in histology images of tissue slides stained with Hematoxylin and Eosin, choosing colon tissue as an example. The proposed Random Polygons Model (RPM) treats each glandular structure in an image as a polygon made of a random number of vertices, where the vertices represent approximate locations of epithelial nuclei. We formulate the RPM as a Bayesian inference problem by defining a prior for spatial connectivity and arrangement of neighboring epithelial nuclei and a likelihood for the presence of a glandular structure. The inference is made via a Reversible-Jump Markov chain Monte Carlo simulation. To the best of our knowledge, all existing published algorithms for gland segmentation are designed to mainly work on healthy samples, adenomas, and low grade adenocarcinomas. One of them has been demonstrated to work on intermediate grade adenocarcinomas at its best. Our experimental results show that the RPM yields favorable results, both quantitatively and qualitatively, for extraction of glandular structures in histology images of normal human colon tissues as well as benign and cancerous tissues, excluding undifferentiated carcinomas.

  20. Fluxo difusivo de fósforo em função de doses e da umidade do solo Influence of phosphorus doses and soil moisture on diffusion flow

    Directory of Open Access Journals (Sweden)

    José P. V. da Costa

    2006-12-01

    Full Text Available A difusão é o mecanismo mais expressivo do transporte do fósforo no solo e depende de vários fatores, como o conteúdo volumétrico de água, a interação fósforo-colóide do solo, a distância da fonte às raízes, o teor e a temperatura do solo. Avaliaram-se os efeitos do conteúdo volumétrico de água e de doses de fósforo no seu fluxo difusivo no solo, em amostras da camada superficial de cinco solos. O experimento consistiu do arranjo fatorial 5 x 8 x 5, referente a cinco materiais de solo, oito níveis de umidade e cinco doses de fósforo, dispostos em blocos ao acaso, com quatro repetições. Como unidade experimental foram utilizados anéis de PVC com volume útil de 360 cm³, que serviram como câmara de difusão. Para avaliação do fluxo difusivo de fósforo nas amostras foram utilizadas lâminas de resina de troca aniônica (IONICS 204UZRA. Pelos resultados, constatou-se que o fluxo difusivo sofre influência da umidade do solo e das doses de fósforo aplicadas.The main phosphorus transport mechanism in the soil is diffusion, which is influenced by several soil factors, such as volumetric water content, phosphorus-colloid interaction, distance between source and roots, content and temperature. The effects of the soil water content and phosphorus doses on the diffusion flow into soil were assessed in samples from the superficial layers of five soils. The treatments were arranged in a 5 x 8 x 5 factorial design corresponding, respectively, to five soils, eight moisture levels and five phosphorus doses. A completely randomized block design with four replications was used. The experimental unit was a PVC ring with a volume of 360 cm³, which acted as a diffusion chamber. Anionic exchange resin slides (IONICS 204UZRA were utilized to assess the phosphorus diffusion flow. Results indicated that the diffusion flow was influenced by phosphorus doses and moisture content.

  1. Evaluation of homogeneity and dose conformity in IMRT planning in prostate radiotherapy; Avaliacao da homogeneidade e conformidade de dose em planejamentos de IMRT de prostata em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Juliane S.; Leidens, Matheus; Estacio, Daniela R., E-mail: juliane.lopes@pucrs.br [Hospital Sao Lucas (PUC-RS), Porto Alegre, RS (Brazil). Servico de Radioterapia; Razera, Ricardo A.Z.; Streck, Elaine E.; Silva, Ana M.M. da [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Faculdade de Fisica

    2015-12-15

    The goal of this study was to evaluate the dose distribution homogeneity and conformity of radiation therapy plans of prostate cancer using IMRT. Data from 34 treatment plans of Hospital Sao Lucas of PUCRS, where those plans were executed, were retrospectively analyzed. All of them were done with 6MV X-rays from a linear accelerator CLINAC IX, and the prescription doses varied between 60 and 74 Gy. Analyses showing the homogeneity and conformity indices for the dose distribution of those plans were made. During these analyses, some comparisons with the traditional radiation therapy planning technic, the 3D-CRT, were discussed. The results showed that there is no correlation between the prescribed dose and the homogeneity and conformity indices, indicating that IMRT works very well even for higher doses. Furthermore, a comparison between the results obtained and the recommendations of ICRU 83 was carried out. It has also been observed that the indices were really close to the ideal values. 82.4% of the cases showed a difference below 5% of the ideal value for the index of conformity, and 88.2% showed a difference below 10% for the homogeneity index. Concluding, it is possible to confirm the quality of the analyzed radiation therapy plans of prostate cancer using IMRT. (author)

  2. Uncertainty analysis in the determination of absorbed dose in water by Fricke chemical dosimetry; Analise das incertezas na determinacao da dose absorvida na agua por dosimetria quimica Fricke

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Fabia; Aguirre, Eder Aguirre, E-mail: fabiavasco@hotmail.com, E-mail: ederuni01@gmail.com [Fundacao do Cancer, Rio de Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2016-07-01

    This work studies the calculations of uncertainties and the level of confidence that involves the process for obtaining the dose absorbed in water using the method of Fricke dosimetry, developed at Laboratorio de Ciencias Radiologicas (LCR). Measurements of absorbance of samples Fricke, irradiated and non-irradiated is going to use in order to calculate the respective sensitivity coefficients, along with the expressions of the calculation of Fricke dose and the absorbed dose in water. Those expressions are used for calculating the others sensitivity coefficients from the input variable. It is going to use the combined uncertainty and the expanded uncertainty, with a level of confidence of 95.45%, in order to report the uncertainties of the measurement. (author)

  3. Dose evaluation in medical staff during diagnostics procedures in interventional radiology; Avaliacao da dose na equipe medica durante procedimentos diagnoticos de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, Fernando A.; Alves, Allan F.F.; Rosa, Maria E.D.; Miranda, Jose R.A. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Moura, Regina [Faculdade de Medicina de Botucatu, SP (Brazil). Departamento de Cirurgia e Ortopedia; Pina, Diana R., E-mail: bacchim@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2014-08-15

    Studies show that personal dosimeters may underestimate the dose values in interventional physicians, especially in extremities and crystalline. The objective of this work was to study the radiation exposure levels of medical staff in diagnostic interventional radiology procedures. For this purpose LiF:Mg,Ti (TLD-100) dosimeters were placed in different regions of the physician body. When comparing with reference dose levels, the maximum numbers of annual procedures were found. This information is essential to ensure the radiological protection of those professionals. (author)

  4. Uncertainties associated to the using of alanine/EPR for the dose interval in the radiotherapy; Incertezas associadas na utilizacao da alanina/RPE para o intervalo de dose da radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, O.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2004-07-01

    The High Doses Laboratory of IPEN is developing a dosimetric system for high doses based on Electron Paramagnetic Resonance (EPR) of free radical radiation induced on alanine. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The main problem for routine implantation is the calibration and the traceability of the system and many errors sources affects the accuracy of the measurements. In this work are discussed same aspects related on the uncertainty evaluation associated with high dose measurement using alanine and EPR. (author)

  5. Criteria for calculation of effective dose from the individual monitoring; Criterios para calculo de dose efetiva a partir da monitoracao individual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-11-15

    This Regulation refers to the requirements of the Regulation CNEN-NN.3.01. 'Basic Act of Radiological Protection', as expressed in the section 5.9, and its application to the effective dose calculation for individual occupationally exposed. from the internal and external individual monitoring data

  6. Study of dose distribution in dental radiology using the Monte Carlo Simulation; Estudo da distribuicao de dose em radiologia odontologica usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S P.J.; Braz, D; Lopes, R T [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Anjos, M J [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica; Barroso, R C.S. [Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica

    2003-11-15

    Full text: The purpose of this study was to study the absorbed dose in mouth due to scattering in teeth in dental radiography using the monte carlo simulation. The Electron Gamma Shower (EGS-4) system of computer codes was used, which is a general purpose package for monte carlo simulation of the coupled transport of electrons and photons in an arbitrary geometry for particles with energies above a few keV up to several TeV. In the case of a X ray dental the low energy photons beam, are removed of the spectrum by the filtration. These low energy photons beam do not contribute in the obtaining of the radiographic image, but they will be contribute in the dose to the patient, however when the incident radiation crosses the tooth it generates a scattering radiation that contributes in the dose received by the patient in the oral cavity (cheek, tooth and oral cavity). Dental radiography is one of the largest single groups of radiographic examination accounting for 32% of radiographs taken in the Brazil. A number of relatively recent improvements in technology, equipment and techniques have the potential to reduce patient radiation dose and improve image quality. To optimize radiation protection all reasonable means should be employed to minimize the dose of each exposure. Dentists therefore need to keep up to date with changes in techniques and equipment and modify their own practice. In preliminary analysis could be notice that the energy below the 30 keV (low energy) is deposited in the cheek. To 30 keV photons there is the maximum absorbed energy in the tooth (about 60%). In 40 keV could be notice that deposited energy is same to teeth and cheek, but up to 40 keV just a small part of energy is deposited, e.g., the great part of energy is transmitted to the inner mouth (oral cavity). (orig.)

  7. Metrological aspects in estimating of radiation dose in patients of nuclear medicine; Aspectos metrologicos na estimativa da dose efetiva de pacientes em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, Anelise

    2015-06-01

    In order to investigate the performance of routine measurements in nuclear medicine services, LNMRI/IRD has been conducting, since 1998, a comparison program of activity measurements of radiopharmaceuticals administered to patients in nuclear medicine. Correction factors are determined from the result of performance analysis in order to determine with better accuracy the activity to be administered to the patients. The present study shows how the correction factor is determined by the ratio between the measurement of the activity at the nuclear medicine center and the activity determined by the LNMRI, which is adopted as reference. It is essential that the dose calibrator be calibrated with standards traceable to national metrology laboratories, so that the activity administered to the patient is neither greater nor smaller than the appropriate value. The corrected values of the activities can be used to calculate with greater accuracy the effective doses received by the patients as well as the risk of cancer. Information related to radiopharmaceuticals and administered activities, type of exams and patient data of three Brazilian hospitals were collected for 1496 adults and 134 children submitted to diagnostic exams employing {sup 99m}Tc and {sup 131}I. Results showed up to a considerable difference between the administered activity and the corrected activity until 30% and 13% above the reference value, respectively, for the {sup 131}I and {sup 99m}Tc was detected. The consequences of these differences were not very critical in this study since the activity measured in dose calibrator before administration was lower than the corrected activity, thus causing a lower effective dose in patients. However, this reduction in activity may result in problems in obtaining the image and consequently, failure diagnosis, delaying correct diagnosis. On the other hand, the overestimation would be worse, mainly in therapeutic applications, because an unnecessarily high absorbed

  8. Procedures, activities and doses in nuclear medicine cycle in Brazil; Procedimentos, atividades e doses no ciclo da medicina nuclear no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Silvia Maria Velasques de

    2005-07-01

    With the aim of characterizing nuclear medicine procedures performed in Brazil, activities of radiopharmaceuticals used and effective doses to patients, data was collected from nuclear medicine institutions in three regions of the country, namely the Southeast, the Northeast and the South regions, representing public hospitals, university hospitals, private and philanthropic institutions with low, medium and high levels of consumption of radiopharmaceuticals. The three chosen regions are responsible for 92% of radiopharmaceutical consumption and imaging equipment in the country. Accordingly, it was requested of some participating institutions to fulfill manually from individual patients data, to record gender, age, weight, height and activities used, for each type of exam as well as the equipment used. In others, the researcher collected data personally. Per institution, nuclear medicine diagnostic procedures ranged from 700 to 13,000 per year, most of which are myocardial and bone imaging procedures, and imaging equipment ranged, from 1 to 8 machines, one or two head SPECT's (hybrid or not). 26.782 patients protocols were analysed, 24.371 adults and 2.411 children and teenagers. For adult patients, differences were observed in the amount of activities used in diagnostic procedures between public and private institutions, with lower average activities used in public institutions. Activities administered to children and their effective doses were difficult to evaluate due to the incompleteness of individual records. Appropriate individual patient records could be adopted without affecting hospitals routine and contributing for a comprehensive evaluation of the radiation protection of nuclear medicine patients. Data from 8.881 workers were analysed, 346 working at nuclear medicine institutions. For monitored workers and measurably exposed workers in nuclear medicine, the values 2.3 mSv and 5.4 mSv, respectively, for effective annual doses are greater than data

  9. Monitoring and studies of environmental cumulative dose of Guangdong Da Ya Bay nuclear-power station by thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Wan Yusong; Li Shili; Yang Lin; Feng Zhanglin; Kong Lingfeng; Yu Jinglan

    1999-01-01

    The author presents the environmental γ radiation routine monitoring by TLD in Guangdong Da Ya Bay Nuclear Power Station and its peripheral 50 km area, which has been put into commercial operation since 1994. The year's monitoring result indicates that there is no obvious change of the total environmental γ radiation in Da Ya Bay Nuclear Power Station and its peripheral 50 km area. But the influence of gas release γ radiation was monitored in 1995 at the monitoring points in the area of 0∼1 km from the nuclear power station

  10. Localization of a defensive volatile 4-hydroxy-4-methylpentan-2-one in the capitate glandular trichomes of Oenothera glazioviana

    Institute of Scientific and Technical Information of China (English)

    Yanyun Tan; Desen Li; Juan Hua; Shihong Luo; Yan Liu; Shenghong Li

    2017-01-01

    Glandular trichomes of plants produce a wide variety of secondary metabolites which are considered as major defensive chemicals. The capitate glandular trichomes of Oenothera glazioviana (Onagraceae) were collected with laser microdissection and analyzed by gas chromatography-mass spectrometry. The volatile compound 4-hydroxy-4-methylpentan-2-one (1) was identified. We found that compound 1 displays antimicrobial, insecticidal, and phytotoxic activities. These results suggest that compound 1 might function as a defensive compound in the capitate glandular trichomes of O. glazioviana against pathogens, insect herbivores, and presumably competitive plants as well.

  11. Localization of a defensive volatile 4-hydroxy-4-methylpentan-2-one in the capitate glandular trichomes of Oenothera glazioviana

    Directory of Open Access Journals (Sweden)

    Yanyun Tan

    2017-06-01

    Full Text Available Glandular trichomes of plants produce a wide variety of secondary metabolites which are considered as major defensive chemicals. The capitate glandular trichomes of Oenothera glazioviana (Onagraceae were collected with laser microdissection and analyzed by gas chromatography–mass spectrometry. The volatile compound 4-hydroxy-4-methylpentan-2-one (1 was identified. We found that compound 1 displays antimicrobial, insecticidal, and phytotoxic activities. These results suggest that compound 1 might function as a defensive compound in the capitate glandular trichomes of O. glazioviana against pathogens, insect herbivores, and presumably competitive plants as well.

  12. Eficácia da dose reduzida de gonadorelina e diferentes prostaglandinas no protocolo ovsynch em vacas holandesas Efficacy of decreasing dose of gonadorelin and comparison between different prostaglandins on ovsynch protocol in lactating Holstein cows

    Directory of Open Access Journals (Sweden)

    R.M. Santos

    2008-12-01

    Full Text Available Avaliou-se a eficácia da dose de 0,10 ou de 0,25mg de gonadorelina nas taxas de ovulação e de sincronização no protocolo Ovsynch e de 150mcg de D-cloprostenol ou 0,530mg de cloprostenol sódico na regressão do corpo lúteo (CL de sete dias e de todos os CL. Foram utilizadas 136 vacas lactantes da raça Holandesa, com média de produção de leite de 23,75,8kg/dia, com 138,4±72,0 dias em lactação. As vacas foram distribuídas aleatoriamente em quatro grupos, de acordo com a dose de gonadorelina e o tipo da prostaglandina. As taxas de ovulação e de sincronização foram de 52,9% e 80,9% para 0,10mg de gonadorelina e de 57,4% e 80,9% para 0,25mg de gonadorelina, respectivamente. A taxa de regressão do CL de sete dias foi de 97,1% para o D-cloprostenol e de 97,5% para o cloprostenol sódico. A taxa de prenhez não foi influenciada pelos tratamentos, mas foi influenciada pela taxa de ovulação à primeira aplicação de gonadorelina, 16,0% vs. 6,6% para as vacas que ovularam e não ovularam, respectivamente. Conclui-se que 0,10mg de gonadorelina foi eficiente e ambas prostaglandinas podem ser usadas em protocolos de sincronização da ovulação.The efficacy of 150mcg D-cloprostenol or 0.530mg cloprostenol sodium on the 7- day corpus luteum (CL regression rate, and of two doses of gonadorelin, 0.10mg vs. 0.25mg, on the ovulation and synchronization rates during the Ovsynch protocol were evaluated. Lactating Holstein cows (n=136, producing 23.75.8kg milk/d and 138.4±72.0 days in milk were randomly assigned to four groups, according to dose of gonadorelin and prostaglandin type. No effect of the products and doses tested on conception rate were observed. The ovulation and synchronization rates using 0.10mg or 0.25mg of gonadorelin were 52.9% and 80.9% vs. 57.4% and 80.9%, respectively. The CL regression rates in cows ovulating after the first GnRH using D-cloprostenol or cloprostenol sodium were 97.1% and 97.5%, respectively. The

  13. Evaluation of absorbed radiation dose rate in a didactic X-ray equipment; Avaliacao da taxa de dose absorvida em um equipamento de raios-X didatico

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Phelipe Amaral Ferreira; Perini, Ana Paula; Neves, Lucio Pereira, E-mail: lucio.neves@ufu.br [Universidade Federal de Uberlandia (UFU), MG (Brazil). Instituto de Fisica

    2016-07-01

    This work was performed in order to create a new didactic experiment in the X-ray apparatus of PHYWE, where the saturation current was obtained through a free air ionization chamber. The values of saturation currents were obtained in two ways. Initially, the anodic DDP was kept constant and the anodic current was varied. In the second way, the anodic current was kept constant while the anodic DDP was varied. Therefore, we were able to evaluate the dependence of the absolved dose rate in relation to the DDP and the tube current. (author)

  14. EFEITO DO TEOR DE GORDURA, VÁCUO E DOSE DE RADIAÇÃO GAMA NA SOBREVIVÊNCIA DE Salmonella TYPHIMURIUM ATCC 14028 EM CARNE BOVINA MOÍDA RESFRIADA

    Directory of Open Access Journals (Sweden)

    C. S. COSTA

    2008-09-01

    Full Text Available

    O trabalho avaliou a sobrevivência de Salmonella Typhimurium ATCC 14028 em carnes bovinas, moída crua e resfriada (2 ºC, através do tratamento com radiação gama (Co60, utilizando doses de 0; 1,5; 2,5 e 3,5 kGy. Além do fator dose de radiação foram avaliadas as influências do emprego de vácuo e de dois teores de gordura da carne bovina moída: baixo (2-4% e alto (11-13%, bem como a interação dos fatores, na redução ou eliminação da bactéria patogênica inoculada. Os resultados demonstraram que os teores de gordura da carne e o emprego de vácuo não influenciaram significativamente a sobrevivência da Salmonella. A dose de radiação gama influenciou a inativação de Salmonella de forma dose dependente até 2,5 kGy, com reduções de 4 ciclos logarítmicos. A dose de 2,5 kGy é suficiente para exercer um controle efetivo de Salmonella em carne bovina moída independentemente do seu teor de gordura e da presença de oxigênio.

  15. Second-harmonic generation as a DNA malignancy indicator of prostate glandular epithelial cells

    International Nuclear Information System (INIS)

    Zheng-Fei, Zhuang; Han-Ping, Liu; Zhou-Yi, Guo; Xiao-Yuan, Deng; Shuang-Mu, Zhuo; Bi-Ying, Yu

    2010-01-01

    This paper first demonstrates second-harmonic generation (SHG) in the intact cell nucleus, which acts as an optical indicator of DNA malignancy in prostate glandular epithelial cells. Within a scanning region of 2.7 μm×2.7 μm in cell nuclei, SHG signals produced from benign prostatic hyperplasia (BPH) and prostate carcinoma (PC) tissues (mouse model C57BL/6) have been investigated. Statistical analyses (t test) of a total of 405 measurements (204 nuclei from BPH and 201 nuclei from PC) show that SHG signals from BPH and PC have a distinct difference (p < 0.05), suggesting a potential optical method of revealing very early malignancy in prostate glandular epithelial cells based upon induced biochemical and/or biophysical modifications in DNA. (geophysics, astronomy and astrophysics)

  16. Treatment of trigeminal neuralgia with low doses of topiramate Tratamento da neuralgia do trigêmeo com baixas doses de topiramato

    Directory of Open Access Journals (Sweden)

    Renan Barros Domingues

    2007-09-01

    Full Text Available Topiramate was administered to eight patients with classical trigeminal neuralgia with or without previous symptomatic therapy with other antiepileptic drugs. The topiramate doses ranged from 50 to 100 mg a day, according to the clinical response and the reported side effects. Three patients had complete symptoms remission, three reported moderate improvement, and the treatment was not effective in two. The most frequently registered side effects were dizziness, somnolence and weight loss. Topiramate can be considered an alternative treatment for patients with trigeminal neuralgia.Oito pacientes com neuralgia do trigêmeo, com ou sem tratamentos prévios com anticonvulsivantes, foram submetidos a tratamento com topiramato. As doses de topiramato variaram de 50 a 100 mg ao dia, de acordo com a resposta clínica e com os efeitos colaterais relatados. Três pacientes obtiveram remissão completa, três relataram melhora parcial e o tratamento com topiramato foi ineficaz em dois pacientes. Os efeitos colaterais mais frequentemente citados foram tontura, sonolência e perda de peso. O topiramato pode ser considerado uma alternativa potencialmente eficaz para o tratamento de pacientes com neuralgia do trigêmeo.

  17. Dedicated breast CT: radiation dose for circle-plus-line trajectory

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; Noo, Frederic

    2012-01-01

    Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD g N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD g N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD g N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2π for the circular scan, the addition of a line trajectory with equal

  18. Ultrastructure of the apical glandular region of the scolex of Proteocephalus torulosus (Cestoda: Proteocephalidae)

    Czech Academy of Sciences Publication Activity Database

    Žďárská, Zdeňka; Scholz, Tomáš; Nebesářová, Jana

    2004-01-01

    Roč. 51, č. 4 (2004), s. 333-338 ISSN 0015-5683 R&D Projects: GA ČR GA524/04/0342; GA AV ČR KSK6005114 Institutional research plan: CEZ:AV0Z6022909 Keywords : Cestoda * Proteocephalus torulosus * apical glandular region Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 0.837, year: 2004

  19. Severe glandular tularemia in a patient treated with anti-tumour necrosis factor for psoriatic arthritis.

    Science.gov (United States)

    Calin, Ruxandra; Caumes, Eric; Reibel, Florence; Ali Mohamed, Anzime; Brossier, Florence; Foltz, Violaine; Boussouar, Samia; Fautrel, Bruno; Maurin, Max; Katlama, Christine; Pourcher, Valérie

    2017-07-01

    A case of severe glandular tularemia in a patient receiving anti-tumour necrosis factor (TNF) therapy is reported here. The patient required prolonged treatment with doxycycline-ciprofloxacin due to early relapse after ciprofloxacin was stopped. Tularemia may have a more severe course in patients receiving anti-TNF. This may thus be an indication for more aggressive treatment. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. MORPHOLOGIC CONSIDERATIONS ABOUT THE WALL OF THE GLANDULAR STOMACH OF YOUNG RABBITS (Oryctolagus cuniculus)

    OpenAIRE

    de Oliveira, Larissa Renata; Molinari, Sonia Lucy; Natali, Maria Raquel Marçal; Michelan, Andrea Cristiane; Scapinello, Claúdio

    2001-01-01

    The morphology of the stomach may vary between species as a function of feeding habits, differences on the cellular composition of the mucosa of the stomach wall and the different functions it carries out. Morphofunctional variations of the stomach of several animals along phylogeny led us to investigate the morphology of the wall of the glandular stomach of rabbits. We used the stomachs of 32 young rabbits (Oryctolagus cuniculus) from the White New Zealand strain, coming from the Experimenta...

  1. Long acting β2-agonist and corticosteroid restore airway glandular cell function altered by bacterial supernatant

    Directory of Open Access Journals (Sweden)

    Nawrocki-Raby Béatrice

    2010-01-01

    Full Text Available Abstract Background Staphylococcus aureus releases virulence factors (VF that may impair the innate protective functions of airway cells. The aim of this study was to determine whether a long-acting β2 adrenergic receptor agonist (salmeterol hydroxynaphthoate, Sal combined with a corticosteroid (fluticasone propionate, FP was able to regulate ion content and cytokine expression by airway glandular cells after exposure to S. aureus supernatant. Methods A human airway glandular cell line was incubated with S. aureus supernatant for 1 h and then treated with the combination Sal/FP for 4 h. The expression of actin and CFTR proteins was analyzed by immunofluorescence. Videomicroscopy was used to evaluate chloride secretion and X-ray microanalysis to measure the intracellular ion and water content. The pro-inflammatory cytokine expression was assessed by RT-PCR and ELISA. Results When the cells were incubated with S. aureus supernatant and then with Sal/FP, the cellular localisation of CFTR was apical compared to the cytoplasmic localisation in cells incubated with S. aureus supernatant alone. The incubation of airway epithelial cells with S. aureus supernatant reduced by 66% the chloride efflux that was fully restored by Sal/FP treatment. We also observed that Sal/FP treatment induced the restoration of ion (Cl and S and water content within the intracellular secretory granules of airway glandular cells and reduced the bacterial supernatant-dependent increase of pro-inflammatory cytokines IL8 and TNFα. Conclusions Our results demonstrate that treatment with the combination of a corticosteroid and a long-acting β2 adrenergic receptor agonist after bacterial infection restores the airway glandular cell function. Abnormal mucus induced by defective ion transport during pulmonary infection could benefit from treatment with a combination of β2 adrenergic receptor agonist and glucocorticoid.

  2. Effect of nitrogen doses on disease severity and watermelon yield Influência de doses de nitrogênio na severidade de doenças e na produtividade da melancia

    Directory of Open Access Journals (Sweden)

    Gil R dos Santos

    2009-09-01

    Full Text Available Nitrogen fertilization is an important step for watermelon (Citrullus lanatus production due to its influence over yield, fruit quality, and disease severity. Currently, the gummy stem blight (Didymella bryoniae and the downy mildew (Pseudoperonospora cubensis can be taken as the most important watermelon diseases, since they impose severe impairment to the crop. Furthermore, studies focusing on plant responses to nitrogen fertilization regarding fruit yield and quality, and disease resistance are rare. Hence, the present study aimed at evaluating the effect of nitrogen doses on fruit yield and quality, and on disease prevalence in watermelon. Two experiments were carried out at the Universidade Federal de Tocantins, employing sprinkler irrigation, in an area previously used to grow watermelon. The experimental design was blocks at random, with five treatments (N doses, applied twice as side-dressing, in kg ha-1, as follows: T1= control treatment without N, T2= 20, T3= 40, T4= 80, and T5= 120, and four replications. Urea (45% N was used as the N source. In the first assay, the highest fruit yield and average weight were observed when 40 kg ha-1 of N were applied. The highest severity of the gummy stem blight was observed when the highest nitrogen doses were applied (80 and 120 kg ha-1. In the second assay, the highest severity levels of the gummy stem blight, as well as of mildew, were observed again when N doses were the highest (80 and 120 kg ha-1. The lowest severity levels for both diseases were observed in the control treatment.A adubação nitrogenada é importante para a cultura da melancia (Citrullus lanatus por afetar diretamente a produtividade, a qualidade dos frutos e a severidade de doenças. Atualmente, o crestamento gomoso (Didymella bryoniae e o míldio (Pseudoperonospora cubensis podem ser consideradas as doenças mais importantes da melancia devido aos prejuízos que podem causar na lavoura. Estudos envolvendo a aplicação de

  3. Crescimento e marcha de absorção de nutrientes da melancieira fertirrigada com diferentes doses de N e K

    Directory of Open Access Journals (Sweden)

    Fabiola Pascoal de Nogueira

    2014-07-01

    Full Text Available 800x600 Na cultura da melancia, a nutrição mineral é um dos fatores mais importante que contribui diretamente na produtividade e qualidade dos frutos. O nitrogênio e o potássio são os dois nutrientes mais exigidos, e deve ser aplicado de acordo com as exigências de cada cultivar.O trabalho teve como objetivo avaliar o crescimento e a marcha de absorção de cultivares de melancia sob diferentes doses de nitrogênio e potássio. O experimento, com as duas variedades de melancia, foi conduzido no delineamento experimental em blocos casualizados no esquema de parcelas subdivididas 13 x 2, sendo o primeiro fator representado pela combinação de doses de nitrogênio (N e potássio (K em arranjo definido segundo o modelo: 2 x 2k+ 2k + 1, sendo k o número de fatores estudados (N e K.  Os totais de N, P e K acumulados no tecido vegetal não variaram com as doses de N ou K aplicadas em fertirrigação.Os máximos valores acumulados de N total foram aos 62 (10,9 g planta-1 e 61 DAT (13,31 g planta-1, para as cultivares Quetzali e Leopard. Para P total o valor máximo ocorreu aos 57 DAT (1,88 g planta-1 e para o K aos 64 DAT (15,15 g planta-1, independentes da cultivar. Normal 0 21 false false false PT-BR X-NONE X-NONE

  4. Evaluation of the dose absorbed by the thyroid of patients undergoing treatment of Graves disease;Avaliacao da dose absorvida pela tireoide de pacientes submetidos ao tratamento da doenca de Graves

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Tiago L.; Filho, Joao A. [Universidade Catolica de Pernambuco (UNICAP), Recife, PE (Brazil). Dept. de Fisica; Silva, Jose M.F. da [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2009-07-01

    The radioiodine is used as complementary treatment of thyroid cancer and as first choice for the treatment of Graves' disease, being efficient, safe and easy administration, but without there is a protocol defined. This work was evaluated the thyroid absorbed dose from its mass and maximum uptake of I-131 obtained in the examination of diagnostic radiology of radiotherapeutic patients undergoing treatment of Graves' disease. Based on the results, it is observed that the thyroid absorbed dose, as much in terms of mass as the maximum uptake of I-131 for different values of administered activity, varies significantly. The analysis of these parameters is an excellent indicator for the pre-define quantity of radionuclide that is administered to the patient in terms of the radiation dose required to achieve an efficient therapeutic treatment. Moreover, it was observed that the thyroid absorbed dose depends on the degree of pathology of the disease, its mass and of the maximum uptake of I-131. (author)

  5. Evaluation of radiological protection and dose of skin entrance in paediatric dentistry examinations; Avaliacao da protecao radiologica e da dose de entrada na pele em exames de odontologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, Helen Jamil [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Vasconcelos, Flavia Maria Nassar de [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Silveira, Marcia Maria Fonseca da [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Fac. de Odontologia; Couto, Geraldo Bosco Lindoso [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Fac. de Odontopediatria; Brasileiro, Izabela Vanderley

    2005-07-01

    In this work the radiological protection conditions and dose at the entrance of pediatric patients undergoing dental intraoral radiographs were evaluated. The study was conducted in two clinics of the dentistry course at the Federal University of Pernambuco, Recife, PB, Brazil, equipped with conventional X-ray apparatus, with 60 and 70 kV. 254 exams of 113 patients between the ages of 3 to 12 years were evaluated. The skin entrance dose was estimated using TLD-100 thermoluminescent dosemeters. During the examination were also recorded information regarding the time of exposure, radiographic technique used, use of thyroid protectors and lead apron, angle and distance of the cone Locator to the patient's skin. The results showed that the input skin doses ranged from 0.3 mGy to 10mGy. The lead apron was used in 71% of exams while the thyroid shield was only used in 58% of the exams. The exposure times ranged from 0,5s to 1,5s. From the results it can be concluded that the radiological procedures are not optimized and that in some cases the patient dose is high.

  6. Granulometric determinations and inhalation dose assessment for atmospheric aerosol contaminated by {sup 137}Cs; Determinazioni granulometriche e valutazioni di dose da inalazione per aerosol atmosferico contaminato da {sup 137}CS

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Luciani, A. [ENEA, Centro Ricerche `E. Clementel`, Bologna (Italy). Dip. Ambiente; Oliviero, L.; Donato, R. [ENEA, Centro Ricerche Saluggia, Vercelli (Italy). Dip. Ambiente

    1996-07-01

    During the redevelopment of Brescia freight-yard a measurement campaign of atmospheric aerosol was carried out: in fact a {sup 137}Cs ground contamination, caused by the permanence of wagons carrying iron materials contaminated by this radionuclide, had been found out. During the redevelopment phases of excavation and can filling the workers were exposed to the danger of radioactive aerosol inhalation. The aim of the measurement campaign was to test the aerosol sampling and granulometric analysis methodologies with their sensitivity related to the inhalation dose assessments. The results of both aerosuspended mass and activity, evaluated by means of a portable cascade impactor, are presented. The granulometries have been interpolated with a log normal distribution using an iterative routine minimizing the square deviation between the calculated and experimental data. The results related to the dose assessments are also presented. These evaluations have been carried out using both the granulometric information obtained and the more recent models (ICRP 66) both the total concentration data and the dose coefficients referring to the standard conditions of ICRP 68 and of the Italian law (D.Lgs. 230/95). Furthermore the significance and the reliability of the dose assessments referring to the different methodologies are discussed, also in relation to the possibility of using this sampling methodologies for other radionuclides and different exposure conditions.

  7. Atypical squamous and glandular cells of undetermined significance (ASCUS and AGUS) of the uterine cervix.

    Science.gov (United States)

    Cenci, M; Vecchione, A

    2000-01-01

    ASCUS (Atypical Squamous Cells of Undetermined Significance) and AGUS (Atypical Glandular Cells of Undetermined Significance), or AGCUS, are two acronyms introduced in 1988 by The Bethesda System (TBS) for reporting borderline cytological changes in cervical cytology. ASCUS and AGUS categories should be subclassified. Five ASCUS subgroups were proposed: 1) ASCUS due to processing defects, 2) with "mature" cytoplasm, 3) in post-menopausal women (a--in the setting of atrophy and b--with estrogen stimulation), 4) atypical metaplasia, and 5) ASCUS with keratinized cytoplasm. AGUS subgroups may be subcategorized in endometrial or endocervical on the basis of origin. Endocervical AGUS should be further qualified, but the analysis of atypical glandular cells may be really difficult and the conclusive diagnosis is frequently "AGUS not otherwise specified". The subclassification of ASCUS and AGUS is useful for an appropriate clinical management, but pertinent patient information (such as age, date of last menstrual period, mechanical therapies, tamoxifen therapy, and others) is needed to avoid an overdiagnosis and consequently an overtreatment. In fact various subgroups require different clinical management. Therefore, an effective communication between cytopathologists and referring physicians is essential in the analysis of squamous and glandular atypias.

  8. Genetic Architecture of Capitate Glandular Trichome Density in Florets of Domesticated Sunflower (Helianthus annuus L.).

    Science.gov (United States)

    Gao, Qing-Ming; Kane, Nolan C; Hulke, Brent S; Reinert, Stephan; Pogoda, Cloe S; Tittes, Silas; Prasifka, Jarrad R

    2017-01-01

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. CGT can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resistance is effective to combat the specialist pest, sunflower moth. However, the genetic basis of CGT density is not well understood in sunflower. In this study, we identified two major QTL controlling CGT density in sunflower florets by using a F 4 mapping population derived from the cross HA 300 × RHA 464 with a genetic linkage map constructed from genotyping-by-sequencing data and composed of 2121 SNP markers. One major QTL is located on chromosome 5, which explained 11.61% of the observed phenotypic variation, and the second QTL is located on chromosome 6, which explained 14.06% of the observed phenotypic variation. The QTL effects and the association between CGT density and QTL support interval were confirmed in a validation population which included 39 sunflower inbred lines with diverse genetic backgrounds. We also identified two strong candidate genes in the QTL support intervals, and the functions of their orthologs in other plant species suggested their potential roles in regulating capitate glandular trichome density in sunflower. Our results provide valuable information to sunflower breeding community for developing host resistance to sunflower insect pests.

  9. CT measurement of breast glandular tissue and its association with testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel); The Chaim Sheba Medical Center, Tel Hashomer (Israel); Rozendorn, Noa; Raskin, Steve; Portnoy, Orith; Sklair, Miri; Marom, Edith M.; Konen, Eli; Amitai, Michal M. [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel)

    2017-02-15

    To evaluate the associations between breast glandular tissues diameters as determined by CT and b-hCG levels, histological types, tumour spread and prognosis in patients with testicular germ cell tumour. Ninety-four patients with pre-treatment CT scan and markers (b-hCG, AFP, LDH) were retrospectively collected. A radiologist measured diameters in all CT examinations and correlation between diameters and log (b-hCG) was assessed (Pearson's coefficient). The ability of measured diameters to predict lymphatic and distant haematogenous metastatic spread was evaluated (ROC curves). The associations between measured diameter cut-off values of 20 and 25 mm and International Germ Cell Cancer Collaborative Group (IGCCCG) classification, lymphatic and distant haematogenous metastatic spread and histological subtypes were evaluated (chi squared test). Breast glandular diameters correlated to log(b-hCG) (r = 0.579) and predicted distant haematogenous metastatic spread (AUC = 0.78). Worse prognosis (intermediate or poor IGCCCG) was shown for 20 mm (27.3 vs. 4.2 %, p = 0.005) and 25 mm (33.3 vs. 6.1 %, p = 0.014). A diameter of 25 mm was associated with non-seminoma (91.7 vs. 48.8 %, p = 0.005). Breast glandular tissue diameters correlated with log(b-hCG) and predicted distant haematogenous metastases. Twenty and 25 mm were associated with worse prognosis and 25 mm was able to distinguish between seminoma and non-seminoma. (orig.)

  10. Antibacterial, modulatory activity of antibiotics and toxicity from Rhinella jimi (Stevaux, 2002) (Anura: Bufonidae) glandular secretions.

    Science.gov (United States)

    Sales, Débora Lima; Morais-Braga, Maria Flaviana Bezerra; Santos, Antonia Thassya Lucas Dos; Machado, Antonio Judson Targino; Araujo Filho, João Antonio de; Dias, Diógenes de Queiroz; Cunha, Francisco Assis Bezerra da; Saraiva, Rogério de Aquino; Menezes, Irwin Rose Alencar de; Coutinho, Henrique Douglas Melo; Costa, José Galberto Martins; Ferreira, Felipe Silva; Alves, Rômulo Romeu da Nóbrega; Almeida, Waltécio de Oliveira

    2017-08-01

    The increase in microorganisms with resistance to medications has caused a strong preoccupation within the medical and scientific community. Animal toxins studies, such as parotoid glandular secretions from amphibians, possesses a great potential in the development of drugs, such as antimicrobials, as these possess bioactive compounds. It was evaluated Rhinella jimi (Stevaux, 2002) glandular secretions against standard and multi-resistant bacterial strains; the effect of secretions combined with drugs; and determined the toxicity using two biologic in vivo models, and a in vitro model with mice livers. Standard strains were used for the determination of the Minimum Inhibitory Concentration (MIC), while for the modulatory activity of antibiotics, the clinical isolates Escherichia coli 06, Pseudomonas aeruginosa 03 and Staphylococcus aureus 10 were used. Modulatory activity was evaluated by the broth microdilution method with aminoglycosides and β-lactams as target antibiotics. The secretions in association with the antibiotics have a significant reduction in MIC, both the aminoglycosides and β-lactams. The toxicity and cytotoxicity results were lower than the values used in the modulation. R. jimi glandular secretions demonstrated clinically relevant results regarding the modulation of the tested antimicrobials. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Radioimmunoassay of glandular kallikrein in human plasma after partial purification by immunoaffinity column

    International Nuclear Information System (INIS)

    Nishimura, Kazutaka; Inoue, Yoshikazu; Kokubu, Tatsuo

    1987-01-01

    Glandular kallikrein in human plasma was partially purified by immunoaffinity column and was measured by a radioimmunoassay (RIA). Plasma was diluted with an equal volume of 10 mmol/l sodium phosphate buffer, pH 7.4, containing 0.9% NaCl (PBS) and was applied to an immunoaffinity column from which glandular kallikrein was eluted with 3 mol/l NaSCN (20 ml). The enzymic fraction was concentrated with an Amicon PM 10 filter and dialyzed against PBS. The final recovery of the enzyme was 51.6 ± 1.6%, determined by using [ 125 I]kallikrein. The usable range of the standard curve covered 2.5-100 ng/tube. The coefficient of variation within the series was 5.9%, and the coefficient of variation between the series was 7.6%. In healthy controls, the plasma content of glandular kallikrein was 1.36 ± 0.39 ng/ml. In patients with acute pancreatitis, the plasma concentration was 8.02 ± 6.15 ng/ml, significantly different from the control group. (Auth.)

  12. Interferência do intervalo de administração da droga sobre a nefrotoxicidade da gentamicina em ratos Influence of the dose regimen on the gentamicin nephrotoxicity in rats

    Directory of Open Access Journals (Sweden)

    Verônica Cunha Rodrigues Oliveira

    2001-06-01

    Full Text Available A insuficiência renal aguda (IRA que apresenta índice de mortalidade em torno de 50%, pode ser definida como um abrupto declínio da filtração glomerular, resultante de isquemia ou toxicidade. A nefrotoxicidade por drogas é uma das etiologias mais freqüentes (27% e sugere-se que o intervalo de administração da droga pode interferir neste efeito colateral, entretanto o melhor regime de administração ainda não está bem estabelecido. Este conhecimento proporcionaria uma atuação mais direcionada de enfermagem na prevenção desta IRA hospitalar. Os resultados obtidos nesta pesquisa, indicam que a infusão única de gentamicina determina menor nefrotoxicidade, provavelmente devido à redução da sua concentração plasmática nas 24hs, diminuindo o acúmulo intracelular deste fármaco, um dos principais mecanismos celulares deste tipo de lesão. Este regime de tratamento mostra portanto vantagens quanto ao custo, efeito nefrotóxico e segurança quanto à eficácia terapêutica.The acute renal failure (ARF, that still presents a righ mortality rate (50% can be defined as an abrupt decline of the glomerular filtration, resultant of isquemic or toxicity event. The drugs nephrotoxicity is one of the most frequent cause (27% of ARF and it is suggested that the interval of administration of the drug can interfere in this side effect, however the best administration regimen is not very well established. This study evaluated the renal function of rats that received gentamicin (100mg/kg in one dose or in two doses (2x 50mg/kg,by intraperitoneal infusion. The results obtained in this research, indicated that the single infusion of gentamicin determined smaller nephrotoxicity by the reduction of serum concentration of this drug in 24 hours, decreasing the intracelular accumulation of this gentamicin, which is one of the main cellular mechanisms of this renal injury. The single dose treatment regime, otherwise, showes advantages not only related

  13. Fungicidas, doses e volumes de calda no controle químico da ferrugem da folha da aveia (Puccinia coronata f. sp. avenae Fungicides, rates and spray volumes in the chemical control of oats crown rust (Puccinia coronata f. sp. avenae

    Directory of Open Access Journals (Sweden)

    Ana R. de Oliveira

    2007-01-01

    Full Text Available A ferrugem da folha (Puccinia coronata f. sp. avenae é a doença mais destrutiva da aveia, e aplicações de fungicidas com volumes baixos de calda podem reduzir a eficácia do controle químico. O objetivo do trabalho foi avaliar a eficiência técnica e econômica de fungicidas, doses e volumes de calda no controle da ferrugem da folha da aveia. O experimento foi conduzido no ano de 2003, na área experimental da FAMV/UPF, com a cultivar de aveia UPFA-20. Os tratamentos foram compostos pelas combinações entre dois fungicidas (tebuconazole, Folicur, 0,75 L ha-1 e epoxiconazole + piraclostrobim, Opera, 0,5 L ha-1, quatro doses (40; 60; 80 e 100% da dose recomendada e dois volumes de calda (100 e 200 L ha-1. O delineamento experimental foi o de blocos casualizados, com esquema fatorial (2x4x2 e quatro repetições. Avaliaram-se a severidade, o controle da ferrugem, a massa do hectolitro, a massa de mil grãos e o rendimento de grãos, realizando-se análise econômica. O volume de calda de 200 L ha-1 proporcionou maiores níveis de controle da doença. As aplicações dos fungicidas com volume de 200 L ha-1 e meia dose ou com 100 L ha-1 e dose cheia proporcionam níveis de controle da ferrugem equivalentes. O resultado econômico difere entre fungicidas e independe do volume de calda. Os efeitos de doses dependem do fungicida.Crown rust (Puccinia coronata f. sp. avenae is the most important disease of oats in Brazil. In susceptible oat cultivars, fungicides are needed to control the disease efficiently. However, spray at low volumes may reduce fungicide performance significantly. A field experiment with the oat cultivar UPFA-20 was carried out at the FAMV/UPF to evaluate the influence of fungicides, rates, and spray volumes on the efficacy of the chemical control for crown rust. The tested treatments combined two fungicides (tebuconazole, Folicur, 0,75 L ha-1; epoxiconazole + pyraclostrobin, Opera, 0,5 L ha-1, four rates (40; 60; 80 and 100

  14. Characterization of fibrillar collagens and extracellular matrix of glandular benign prostatic hyperplasia nodules.

    Directory of Open Access Journals (Sweden)

    Tyler M Bauman

    Full Text Available Recent studies have associated lower urinary tract symptoms (LUTS in men with prostatic fibrosis, but a definitive link between collagen deposition and LUTS has yet to be demonstrated. The objective of this study was to evaluate ECM and collagen content within normal glandular prostate tissue and glandular BPH, and to evaluate the association of clinical parameters of LUTS with collagen content.Fibrillar collagen and ECM content was assessed in normal prostate (48 patients and glandular BPH nodules (24 patients using Masson's trichrome stain and Picrosirius red stain. Second harmonic generation (SHG imaging was used to evaluate collagen content. Additional BPH tissues (n = 47 were stained with Picrosirius red and the association between clinical parameters of BPH/LUTS and collagen content was assessed.ECM was similar in normal prostate and BPH (p = 0.44. Total collagen content between normal prostate and glandular BPH was similar (p = 0.27, but a significant increase in thicker collagen bundles was observed in BPH (p = 0.045. Using SHG imaging, collagen content in BPH (mean intensity = 62.52; SEM = 2.74 was significantly higher than in normal prostate (51.77±3.49; p = 0.02. Total collagen content was not associated with treatment with finasteride (p = 0.47 or α-blockers (p = 0.52, pre-TURP AUA symptom index (p = 0.90, prostate-specific antigen (p = 0.86, post-void residual (PVR; p = 0.32, prostate size (p = 0.21, or post-TURP PVR (p = 0.51. Collagen content was not associated with patient age in patients with BPH, however as men aged normal prostatic tissue had a decreased proportion of thick collagen bundles.The proportion of larger bundles of collagen, but not total collagen, is increased in BPH nodules, suggesting that these large fibers may play a role in BPH/LUTS. Total collagen content is independent of clinical parameters of BPH and LUTS. If fibrosis and overall ECM deposition are

  15. Morphology and histochemistry of glandular trichomes of Orobanche alba Stephan ex Willd

    Directory of Open Access Journals (Sweden)

    Aneta Sulborska

    2014-04-01

    Full Text Available Orobanche alba Stephan ex Willd is an achlorophyllous root parasite rare in Poland. It prefers dry and sunny slopes, xerothermic grasslands and pastures, mountain pastures, light scrubs, and rock fissures and ledges. The hosts of O. alba include Thymus polytrichus A. ern. ex Borbás, Clinopodium vulgare L. and Origanum vulgare L. The tick and fleshy 10-70 cm high stem in this species bears an inflorescence composed of zygomorphic, white or yellow “spotted” flowers covered by purple glandular trichomes. Glandular trichomes of this type are also borne on other parts of the plant, i.e. on the stem, scaly leaves, sepals, filaments, and the style. The secondary metabolites secreted by the glandular trichomes are related to defense of plants against the attack of herbivores and pathogens or act as attractants to pollinators or for fruit dispersal. The micromorphology and histochemistry of the glandular trichomes in O. alba were examined using scanning electron and light microscopes. In order to determine the type of secondary metabolites produced by the trichomes, the flowing histochemical assays were used: Sudan III and neutral red for detection of lipophilic compounds, IKI for detection of starch, and FeCl3 for detection of phenolic compounds. The peltate glandular trichomes of O. alba were characterised by a varied length (0.15‑0.48 mm and different activity phases. The trichome was composed of one larger basal epidermal cell, 1-3 hyaline stalk cells with a striated cuticle, a neck cell with a smooth cuticle on the surface, and a globose head formed of 8-18 secretory cells arranged in a circle. Many stalk cells of the trichomes, particularly those located on the corolla, contained anthocyanins, which give the trichomes dark carmine colour. In turn, the colour of the heads was dependent on trichome age: the heads were brown in older trichomes and yellow in younger hairs. Secretion was produced by both young and older trichomes. It penetrated

  16. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Science.gov (United States)

    Chen, Fangfang; Hao, Fuhua; Li, Changfu; Gou, Junbo; Lu, Dayan; Gong, Fujun; Tang, Huiru; Zhang, Yansheng

    2013-01-01

    Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin) were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  17. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Directory of Open Access Journals (Sweden)

    Fangfang Chen

    Full Text Available Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  18. Produtividade da cultura da melancia em função de fontes e doses de potássio Yield of watermelon fruits as a function of sources and doses of potassium

    Directory of Open Access Journals (Sweden)

    Arthur Bernardes Cecílio Filho

    2004-06-01

    Full Text Available Foram conduzidos dois experimentos em propriedades rurais próximas à cidade de Borborema - SP, nos períodos de outubro a dezembro de 2001 e de fevereiro a abril de 2002, com o objetivo de avaliar a produtividade de melancia (Citrullus lanatus (Thumb. Matsum. & Nakai, híbrido Tide, em função de fontes e doses de potássio. O delineamento experimental utilizado foi o de blocos casualizados completos, em esquema fatorial 3 x 4, com três repetições, sendo utilizadas as fontes: cloreto KCl, nitrato (KNO3 e sulfato de potássio (K2SO4 e as doses: 50; 100; 200 e 300 kg de K2O ha-1. Foram avaliados o peso médio de fruto, o número de frutos e produção por planta e produtividade. O maior número de frutos por planta estimado foi obtido nas doses de 190 e 300 kg K2O ha-1, respectivamente, nas fontes KNO3 e KCl. Não houve diferença significativa entre as doses para K2SO4. Para o peso médio de fruto, houve diferença significativa entre as fontes apenas no cultivo de fevereiro a abril de 2002, quando o KCl proporcionou maior peso. A maior produção por planta foi obtida com K2SO4, seguido por KNO3 e KCl. Entretanto, as doses de potássio para as máximas produtividades foram de 132, 193 e 205 kg K2O ha-1, respectivamente, para as fontes K2SO4, KNO3 e KCl. O plantio de outubro a dezembro de 2001 proporcionou maior peso médio, produção de frutos por planta e produtividade, ao passo que o maior número de frutos por planta foi obtido no cultivo de fevereiro a abril de 2002.Two field experiments were conducted in Borborema, State of São Paulo, from periods of October to December of the 2001 and February to April of 2002, with the objective of evaluate the yield of watermelon (Tide hybrid (Citrullus lanatus (Thumb. Matsum. & Nakai in function of sources and doses of potassium. The experimental design was a randomized complete block, with three replications, in a 3 x 4 factorial scheme, being evaluated sources: potassium chloride, nitrate and

  19. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology;Analise preliminar das doses para avaliacao da qualidade da imagem em exames radiograficos na radiologia veterinaria

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Melo, Camila S.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  20. Study of the heterogeneity effects of lung in the evaluation of absorbed dose in radiotherapy; Estudo dos efeitos da heterogeneidade de pulmao na avaliacao da dose absorvida em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho

    2006-02-15

    The main objective of radiotherapy is to deliver the highest possible dose to the tumour, in order to destroy it, reducing as much as possible the doses to healthy tissues adjacent to the target volume. Therefore, it is necessary to do a planning of the treatment. The more complex is the treatment, the more difficult the planning will be, demanding computation sophisticated methods in its execution, in order to consider the heterogeneities present in the human body. Additionally, with the appearing of new radiotherapeutic techniques, that used irradiation fields of small area, for instance, the intensity modulated radiotherapy, the difficulties for the execution of a reliable treatment planning, became still larger. In this work it was studied the influence of the lung heterogeneity in the planning of the curves of percentage depth dose, PDP, obtained with the Eclipse{sup R} planning system for different sizes of irradiation fields, using the correction algorithms for heterogeneities available in the planning system: modified Batho, general Batho and equivalent tissue-air ratio. A thorax phantom, manufactured in acrylic, containing a region made of cork to simulate the lung tissue, was used. The PDP curves generated by the planning system were compared to those obtained by Monte Carlo simulation and with the use of thermoluminescent, TL, dosimetry. It was verified that the algorithms used by the Eclipse{sup R} system for the correction of heterogeneity effects are not able to generate correct results for PDP curves in the case of small fields, occurring differences of up to 100%, when the 1x1 cm{sup 2} treatment field is considered. These differences can cause a considerable subdosage in the lung tissue, reducing the possibility of the patient cure. (author)

  1. Análise da distribuição espacial de dose absorvida em próton terapia ocular Spatial distribution analysis of absorbed dose in ocular proton radiation therapy

    Directory of Open Access Journals (Sweden)

    Marília Tavares Christóvão

    2010-08-01

    Full Text Available OBJETIVO: Propõe-se avaliar os perfis de dose em profundidade e as distribuições espaciais de dose para protocolos de radioterapia ocular por prótons, a partir de simulações computacionais em código nuclear e modelo de olho discretizado em voxels. MATERIAIS E MÉTODOS: As ferramentas computacionais empregadas foram o código Geant4 (GEometry ANd Tracking Toolkit e o SISCODES (Sistema Computacional para Dosimetria em Radioterapia. O Geant4 é um pacote de software livre, utilizado para simular a passagem de partículas nucleares com carga elétrica através da matéria, pelo método de Monte Carlo. Foram executadas simulações computacionais reprodutivas de radioterapia por próton baseada em instalações pré-existentes. RESULTADOS: Os dados das simulações foram integrados ao modelo de olho através do código SISCODES, para geração das distribuições espaciais de doses. Perfis de dose em profundidade reproduzindo o pico de Bragg puro e modulado são apresentados. Importantes aspectos do planejamento radioterápico com prótons são abordados, como material absorvedor, modulação, dimensões do colimador, energia incidente do próton e produção de isodoses. CONCLUSÃO: Conclui-se que a terapia por prótons, quando adequadamente modulada e direcionada, pode reproduzir condições ideais de deposição de dose em neoplasias oculares.OBJECTIVE: The present study proposes the evaluation of the depth-dose profiles and the spatial distribution of radiation dose for ocular proton beam radiotherapy protocols, based on computer simulations in nuclear codes and an eye model discretized into voxels. MATERIALS AND METHODS: The employed computational tools were Geant4 (GEometry ANd Tracking Toolkit and SISCODES (Sistema Computacional para Dosimetria em Radioterapia - Computer System for Dosimetry in Radiotherapy. Geant4 is a toolkit for simulating the passage of particles through the matter, based on Monte Carlo method. Computer simulations

  2. Glandular trichomes in Connarus suberosus (Connaraceae: distribution, structural organization and probable functions

    Directory of Open Access Journals (Sweden)

    João Donizete Denardi

    2012-03-01

    Full Text Available Connarus suberosus is a typical species of the Brazilian Cerrado biome, and its inflorescences and young vegetative branches are densely covered by dendritic trichomes. The objective of this study was to report the occurrence of a previously undescribed glandular trichome of this species. The localization, origin and structure of these trichomes were investigated under light, transmission and scanning electron microscopy. Collections were made throughout the year, from five adult specimens of Connarus suberosus near Botucatu, São Paulo, Brazil, including vegetative and reproductive apices, leaves and fruits in different developmental stages, as well as floral buds and flowers at anthesis. Glandular trichomes (GTs occurred on vegetative and reproductive organs during their juvenile stages. The GTs consisted of a uniseriate, multicellular peduncle, whose cells contain phenolic compounds, as well as a multicellular glandular portion that accumulates lipids. The glandular cell has thin wall, dense cytoplasm (with many mitochondria, plastids and dictyosomes, and a large nucleus with a visible nucleolus. The starch present in the plastids was hydrolyzed during the synthesis phase, reducing the density of the plastid stroma. Some plastids were fused to vacuoles, and some evidence suggested the conversion of plastids into vacuoles. During the final activity stages of the GTs, a darkening of the protoplasm was observed in some of the glandular cells, as a programmed cell death; afterwards, became caducous. The GTs in C. suberosus had a temporal restriction, being limited to the juvenile phase of the organs. Their presence on the exposed surfaces of developing organs and the chemical nature of the reserve products, suggest that these structures are food bodies. Field observations and detailed studies of plant-environment interactions, as well as chemical analysis of the reserve compounds, are still necessary to confirm the role of these GTs as feeding

  3. Efeito da filtração adicional nas doses de radiação e na qualidade das imagens nos exames videofluoroscópicos Effect of additional filtration on radiation doses and image quality in videofluoroscopic studies

    Directory of Open Access Journals (Sweden)

    Milton Melciades Barbosa Costa

    2009-12-01

    Full Text Available OBJETIVO: Investigar o efeito da adição de filtros de alumínio (1 mm e cobre (0,4 mm na redução das doses efetivas de radiação e na qualidade das imagens em exames videofluoroscópicos. MATERIAIS E MÉTODOS: Ao tubo de raios X adicionou-se câmara de ionização conectada a um eletrômetro para medir o produto kerma-área, com técnica de 65 kVp e 0,7 mA, sem e com adição dos filtros. Foi medida resolução espacial, a de baixo contraste e tons de cinza, utilizando os objetos de teste de Leeds. Quinze voluntários tiveram o produto kerma-área/minuto do estudo faríngeo comparados, dez com filtração e base e cinco com adição dos filtros associados. RESULTADOS: A adição dos filtros separados ou associados produziu expressiva redução do produto kerma-área, com ganho na qualidade das imagens videofluoroscópicas determinado pela maior separação dos tons de cinza e aumento da relação brilho/contraste da curva de cinza. CONCLUSÃO: A interposição adicional de filtros de alumínio e cobre, em especial quando associados, melhora a qualidade das imagens, com expressiva redução das doses de radiação necessárias à sua geração.OBJECTIVE: The purpose of thys study was to investigate the effect of the addition of aluminum (1 mm and copper (0.4 mm filters on effective radiation doses and image quality in videofluoroscopy. MATERIALS AND METHODS: An ionization chamber coupled with an electrometer was added to x-ray tube to measure the kerma area product with 65 kV and 0.7 mA technique, without and with additional filtration. Low contrast, gray scale and spatial resolution were measured utilizing Leeds test objects. Fifteen volunteers underwent pharynx study, ten without and five with aluminum and cooper filters associated, and had the kerma area product/minute compared. RESULTS: The specified filters addition, either separated or associated, allowed an expressive decrease in kerma area product besides an actual improvement in the

  4. In vitro study of dose-response relationship of fluoride with dental enamel = Estudo in vitro da relação dose-resposta do fluoreto com esmalte dental

    Directory of Open Access Journals (Sweden)

    Arthur, Rodrigo Alex

    2007-01-01

    Full Text Available Modelos in vitro para avaliação da reatividade do fluoreto (F devem apresentar resposta dose-efeito. Dessa forma, o objetivo desse estudo foi avaliar a relação dose-resposta do fluoreto presente em solução aquosa com o esmalte dental bovino. Cento e vinte blocos de esmalte bovino (5 × 5 × 2 mm, 60 hígidos e 60 com lesão artificial de cárie, foram submetidos durante 10 minutos à água destilada e deionizada (controle negativo e soluções aquosas contendo 50, 100, 200 ou 400 µg F/mL. Cada grupo experimental recebeu 12 blocos hígidos e 12 blocos com lesão artificial de cárie. Duas camadas consecutivas de esmalte dental foram removidas de todos os blocos dentais por meio de ataque ácido e o fluoreto extraído foi determinado com eletrodo específico. Os resultados de fluoreto incorporado foram expressos em µg por g de esmalte removido, considerando a quantidade total das duas camadas. A incorporação de fluoreto pelo esmalte hígido mostrou uma relação dose-resposta linear (p = 0,0001, enquanto que os blocos com lesão de cárie mostraram relação polinomial quadrática (p < 0,0001. Os resultados sugerem que o modelo in vitro de reatividade empregado no presente estudo é apropriado para avaliar a relação doseresposta entre o fluoreto em solução aquosa e aquele incorporado pelo esmalte dental bovino hígido ou com lesão artificial de cárie

  5. Capitate glandular trichomes in Aldama discolor (Heliantheae - Asteraceae): morphology, metabolite profile and sesquiterpene biosynthesis.

    Science.gov (United States)

    Bombo, A B; Appezzato-da-Glória, B; Aschenbrenner, A-K; Spring, O

    2016-05-01

    The capitate glandular trichome is the most common type described in Asteraceae species. It is known for its ability to produce various plant metabolites of ecological and economic importance, among which sesquiterpene lactones are predominant. In this paper, we applied microscopy, phytochemical and molecular genetics techniques to characterise the capitate glandular trichome in Aldama discolor, a native Brazilian species of Asteraceae, with pharmacological potential. It was found that formation of trichomes on leaf primordia of germinating seeds starts between 24 h and 48 h after radicle growth indicates germination. The start of metabolic activity of trichomes was indicated by separation of the cuticle from the cell wall of secretory cells at the trichome tip after 72 h. This coincided with the accumulation of budlein A, the major sesquiterpene lactone of A. discolor capitate glandular trichomes, in extracts of leaf primordia after 96 h. In the same timeframe of 72-96 h post-germination, gene expression studies showed up-regulation of the putative germacrene A synthase (pGAS2) and putative germacrene A oxidase (pGAO) of A. discolor in the transcriptome of these samples, indicating the start of sesquiterpene lactone biosynthesis. Sequencing of the two genes revealed high similarity to HaGAS and HaGAO from sunflower, which shows that key steps of this pathway are highly conserved. The processes of trichome differentiation, metabolic activity and genetic regulation in A. discolor and in sunflower appear to be typical for other species of the subtribe Helianthinae. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  6. Efeitos de algumas características do solo na resposta da planta a doses de herbicidas Effect of some soil characteristics on plant response to herbicide dosis

    Directory of Open Access Journals (Sweden)

    E. M. Paulo

    1991-01-01

    Full Text Available Foram estudados em casa de vegetação o tempo de sobre vivência de oito espécies olerícolas a aplicação de atrazina nas doses correspondentes a 1,8 e 3,2 kg/ha, e de diuron nas doses de 1,2 e 2,0 kg/ ha, em três tipos de solos ácidos tropicais. Os resultados mostraram alta correlação linear entre o tempo médio de vida das plântulas com teores de matéria orgânica, capacidade de troca catiônica (CTC efetiva e pH do solo; e baixas correlações com teores de argila mais silte. Os resultados indicam ser mais adequado tomar como base a característica CTC do solo em lugar da sua classificação textural para fins de recomendação das doses dos herbicidas.A study was conducted in green house to determine the survival time of eight vegetable plant species to soil application of 1,8 and 3,2 kg/ha of atrazine, and 1,2 and 2,0 kg/ha of diuron, in three tropical soils. High line ar correlation was obtained betwe en avera ge survi val time and organic matter content, cation exchange capacity (CEC and soil pH; and low correlation with clay or clay plus silt content. The results lead to the conclusion that it seems more consistent to consider CEC inste ad of soil texture on dosis recommendation fow both herbicides.

  7. Componentes da Produção de Forragem em Pastagens dos Capins Tanzânia e Mombaça Adubadas com Quatro Doses de NPK

    Directory of Open Access Journals (Sweden)

    Quadros Danilo Gusmão de

    2002-01-01

    Full Text Available O trabalho foi conduzido na FCAV-Unesp, em Jaboticabal-SP, para avaliar os efeitos de quatro doses combinadas de NPK sobre os componentes da produção e das perdas de matéria seca (MS em pastagens dos cultivares Tanzânia e Mombaça de Panicum maximum Jacq., manejadas com 28 dias de descanso e com altura média de 30 cm de resíduo pós-pastejo. As avaliações foram realizadas em parcelas de 96 m² segundo um fatorial 2 (cultivares x 4 (doses de NPK, em blocos completos ao acaso, com três repetições. As adubações estudadas corresponderam ao decréscimo em 30 % e aos acréscimos em 30 e 60 % de uma dose "padrão" com 145; 21,6 e 180 kg/ha de N, P2O5 e K2O, respectivamente (referente a 1,2; a 0,08; e a 1,2 % de N, P e K na MS, com produção estimada em 12000 kg/ha. A MS verde (MSV em pré-pastejo e no resíduo aumentou linearmente com a adubação, com maiores valores obtidos para o cv. Mombaça (9183 e 5227 kg/ha, respectivamente do que para o cv. Tanzânia (6275 e 3808 kg/ha, respectivamente. A participação de lâminas foliares na MSV em pré-pastejo foi menor no cv. Tanzânia (51 % do que no cv. Mombaça (54 %. A densidade de perfilhos não variou com a adubação. O aumento do peso de perfilho com a elevação das doses de NPK resultou em maiores produções de MSV. A MS senescida (média de 3108 kg/ha de MS não diferiu entre cultivares. De modo geral, quanto maior a dose de adubo aplicado, maiores foram a taxa de acúmulo diário de MSV e a MSV perdida por pisoteio. O cv. Mombaça apresentou maior potencial de resposta à adubação do que o cv. Tanzânia, com taxas de lotação de 6,2 e 4,0 UA/ha, respectivamente.

  8. Radiation doses from mammography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Young, B.F.; Young, J.G.; Tingey, D.R.C.

    1991-05-01

    During 1989-90 the Australian Radiation Laboratory conducted a postal survey of at least 90% of the mammographic facilities in Australia. The primary aim of the survey was to measure the mean glandular dose (MGD) and the X-ray beam half value layer (HVL) for a typical mammograph. The MGD and HVL were measured with a specially designed tissue equivalent monitor. In all, 258 mammographic centres were surveyed. It was found that for centres using film-screen imaging, the average mean glandular dose was 1.83 mGy for centres using grids and 0.84 mGy for centres not using grids. In addition to the MGD and HVL, comprehensive statistical information was collected and data is presented on the types of equipment and techniques used, the number and age of patients and demographic distribution of centres. Results indicate that the use of a grid is the major factor determining dose and several other factors appear to have minor effects. In view of the distribution of MGD, it is recommended that the mean glandular dose per image, for a 5 cm compressed breast thickness, should not exceed 2.0 mGy when a grid is used and 1.0 mGy without a grid. 63 refs., 11 tabs., 15 figs

  9. Produção e qualidade da moranga híbrida em resposta a doses de nitrogênio Yield and quality of hybrid squash (pumpkin in response to nitrogen doses

    Directory of Open Access Journals (Sweden)

    Marinalva W Pedrosa

    2012-06-01

    Full Text Available Foram avaliados os efeitos de doses de N na produção e qualidade da moranga hibrida cv. Tetsukabuto (Takaima F1 em experimento na EPAMIG Centro Oeste, Prudente de Morais (MG, de 25/08 a 03/12/2008. Foram avaliadas cinco doses de nitrogênio (0; 37,5; 75; 150; 300 kg ha-1, na forma de uréia, divididas em quatro aplicações (30% no plantio, 20% aos 20 dias, 30% aos 40 dias e 20% aos 60 dias após a emergência, num delineamento experimental de blocos casualizados com quatro repetições. As doses de N influenciaram significativamente as características avaliadas. O número de frutos aumentou de 2.498 ao ponto de máximo de 6.794 frutos ha-1 com a aplicação de 219 kg ha-1 de N. O diâmetro e a espessura da polpa do fruto aumentaram de 14,97 e 2,33 cm, até atingirem os pontos máximos de 17,74 e 2,80 cm nas doses de 171 e 128 kg ha-1 de N, respectivamente. O teor de sólidos solúveis na polpa de frutos de moranga híbrida aumentou com o aumento das doses de N observando-se com a aplicação de 300 kg ha-1 de N teor de 8ºBrix. A produtividade de frutos foi também influenciada pelas doses de N estimando-se como valor máximo 11,55 t ha-1 de frutos com a aplicação de 300 kg ha-1 de N. A dose estimada de N relativa à máxima eficiência econômica foi obtida com a aplicação de 262 kg ha-1, considerando os preços de R$ 2,41 kg-1 de N e de R$ 560,00 t-1 de moranga.An experiment was carried out at EPAMIG Centro Oeste, Prudente de Morais, Minas Gerais state, Brazil, from August 25 to December 2, 2008, to evaluate the effects of N rates on production and quality of hybrid squash cv. Tetsukabuto (Takaima F1. The treatments were five N rates (0, 37.5, 75, 150, 300 kg ha-1, as urea, split in four applications (30% at planting date, 20% at 20 days, 30% at 40 days and 20% at 60 days after emergence in a randomized complete block design, with four replications. The N rates significantly affected the characteristics evaluated. The number of fruits

  10. Comparação da eficácia de doses iguais de acetaminofeno retal e oral em crianças Comparison of antipyretic effectiveness of equal doses of rectal and oral acetaminophen in children

    Directory of Open Access Journals (Sweden)

    Sedigha Akhavan Karbasi

    2010-06-01

    Full Text Available OBJETIVO: Comparar uma dose de acetaminofeno oral e retal e avaliar a aceitabilidade do acetaminofeno retal, uma vez que o acetaminofeno oral e retal é amplamente usado como agente antipirético em crianças com febre e a eficiência comparativa dessas duas preparações não está bem estabelecida. MÉTODOS: Neste estudo prospectivo de grupos paralelos, foram incluídas 60 crianças admitidas na emergência ou clínica ambulatorial pediátrica em um hospital terciário, com idade entre 6 meses e 6 anos e com temperatura retal acima de 39 °C. Os pacientes foram distribuídos aleatoriamente em dois grupos de mesmo tamanho. O grupo 1 recebeu 15 mg/kg de acetaminofeno retal, e o grupo 2 recebeu a mesma dose oralmente. A temperatura foi registrada no tempo zero e 1 e 3 horas após administração da droga. RESULTADOS: No primeiro grupo, a redução média de temperatura, 1 e 3 horas após administração do acetaminofeno, foi de 1,07±0,16 (p 0,05. CONCLUSÃO: As preparações oral e retal de acetaminofeno têm eficácia antipirética equivalente em crianças. A via retal mostrou ser tão aceitável quanto a oral entre os pais.OBJECTIVE: To compare a dose of oral and rectal acetaminophen and to evaluate acceptability of rectal acetaminophen, since oral and rectal acetaminophen is widely used as an antipyretic agent in febrile children and the comparative effectiveness of these two preparations is not well established. METHODS: In this prospective parallel group designed study, 60 children who presented to the emergency department or outpatient pediatric clinic at a tertiary hospital and aged from 6 months to 6 years with rectal temperature over 39 °C were enrolled. Patients were randomly assigned to two equal-sized groups. Group 1 received 15 mg/kg acetaminophen rectally and group 2 received the same dose orally. Temperature was recorded at baseline and 1 and 3 hours after drug administration. RESULTS: In the first group, mean decrease in

  11. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  12. Glandular differentiation in dedifferentiated chondrosarcoma: molecular evidence of a rare phenomenon.

    Science.gov (United States)

    Jour, George; Liu, Yajuan; Ricciotti, Robert; Pritchard, Colin; Hoch, Benjamin L

    2015-09-01

    Epithelial glandular differentiation in dedifferentiated chondrosarcoma has not been described. Our patient was a 64-year-old man with a history of prostate cancer status post-radiation and hormonal therapy. On screening bone scan, he was found to have increased uptake in his right femoral shaft. Biopsy revealed intermediate-grade conventional chondrosarcoma. Subsequent femoral resection was remarkable for an intermediate-grade chondrosarcomatous component juxtaposed to an area composed of anastomosing nests and cords of malignant epithelial cells showing nuclear atypia and increased mitotic activity. A fibroblastic-appearing spindle cell population was intimately associated with the epithelial cells. The epithelial cells labeled with 34bE12, AE1/AE3, EMA, and Vimentin (both spindled and epithelial components) while being negative for prostate-specific antigen, prostate specific acid phosphatase, cytokeratin 20, thyroid transcription factor-1, and CDX2. The patient developed local recurrence 9 months after the initial resection but has had no metastatic disease and consistently undetectable prostate-specific antigen levels. Deep parallel sequencing of the dedifferentiated component showed a nonsynonymous mutation at exon 4 of IDH1 gene at codon R132 leading to a substitution of arginine, with serine confirming glandular differentiation in dedifferentiated chondrosarcoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Development and Structure of Internal Glands and External Glandular Trichomes in Pogostemon cablin

    Science.gov (United States)

    Guo, Jiansheng; Yuan, Yongming; Liu, Zhixue; Zhu, Jian

    2013-01-01

    Pogostemon cablin possesses two morphologically and ontogenetically different types of glandular trichomes, one type of bristle hair on the surfaces of leaves and stems and one type of internal gland inside the leaves and stems. The internal gland originates from elementary meristem and is associated with the biosynthesis of oils present inside the leaves and stems. However, there is little information on mechanism for the oil biosynthesis and secretion inside the leaves and stems. In this study, we identified three kinds of glandular trichome types and two kinds of internal gland in the Pogostemon cablin. The oil secretions from internal glands of stems and leaves contained lipids, flavones and terpenes. Our results indicated that endoplasmic reticulum and plastids and vacuoles are likely involved in the biosynthesis of oils in the internal glands and the synthesized oils are transported from endoplasmic reticulum to the cell wall via connecting endoplasmic reticulum membranes to the plasma membrane. And the comparative analysis of the development, distribution, histochemistry and ultrastructures of the internal and external glands in Pogostemon cablin leads us to propose that the internal gland may be a novel secretory structure which is different from external glands. PMID:24205002

  14. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    Science.gov (United States)

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  15. CE e RAS do extrato de saturação do solo sob diferentes níveis de salinidade e doses de nitrogênio no cultivo da abobora

    Directory of Open Access Journals (Sweden)

    Max Venicius Teixeira da Silva

    2014-07-01

    Full Text Available 800x600 A agricultura irrigada depende tanto da quantidade como da qualidade da água; no entanto, o aspecto qualidade tem sido desprezado devido ao fato de que, no passado, em geral as fontes de água, eram abundantes, de boa qualidade. O trabalho teve como objetivo estudar a condutividade elétrica e razão de adsorção do sódio no extrato de saturação do solo no cultivo da abobora sob diferentes níveis salinos da água de irrigação e doses de nitrogênio. A água de irrigação disponível na Fazenda Experimental é proveniente de um poço perfurado do aqüífero Arenito Açu, com profundidade aproximada de 800 m, com água de boa qualidade, e condutividade elétrica da água (CEa em torno de0,5 dS m-1. Adotou-se o delineamento experimental em blocos ao acaso, em esquema de parcelas subdivididas 5 x 3, com quatro repetições. Os tratamentos foram constituídos dos cinco níveis de salinidade (0,5, 1,5, 2,5, 3,5 e 4,5 dS m-1, e três níveis de nitrogênio: N1 = 27,37; N2 = 91,25 e N3 = 155,12 kg ha-1 correspondente a 30%, 100% e 170%, da recomendação de nitrogênio. Houve um aumento da salinidade do extrato de saturação com incremento dos níveis salinos da água e adubação nitrogenada. Os maiores valores de CEes foram verificados na CE (4,5 dS.m-1 e 170% da dose  de nitrogênio recomendada pelos produtores de abobora. A razão de adsorção de Sódio (RASes cresceu proporcional com os valores da condutividade elétrica da água de irrigação Normal 0 21 false false false PT-BR X-NONE X-NONE

  16. Mammographic dose survey in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Leos [National Radiation Protection Institute, Prague (Czech Republic); Rada, Jiri [National Radiation Protection Institute, Ostrava (Czech Republic)

    2006-07-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  17. Mammographic dose survey in the Czech Republic

    International Nuclear Information System (INIS)

    Novak, Leos; Rada, Jiri

    2006-01-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  18. Human papillomavirus prevalence and type-distribution in cervical glandular neoplasias

    DEFF Research Database (Denmark)

    Holl, Katsiaryna; Nowakowski, Andrzej M; Powell, Ned

    2015-01-01

    Cervical glandular neoplasias (CGN) present a challenge for cervical cancer prevention due to their complex histopathology and difficulties in detecting preinvasive stages with current screening practices. Reports of human papillomavirus (HPV) prevalence and type-distribution in CGN vary, providing...... uncertain evidence to support prophylactic vaccination and HPV screening. This study [108288/108290] assessed HPV prevalence and type-distribution in women diagnosed with cervical adenocarcinoma in situ (AIS, N = 49), adenosquamous carcinoma (ASC, N = 104), and various adenocarcinoma subtypes (ADC, N = 461...... of CGN are HPV16/18/45-positive, the incorporation of prophylactic vaccination and HPV testing in cervical cancer screening are important prevention strategies. Our results suggest that special attention should be given to certain rarer ADC subtypes as most appear to be unrelated to HPV....

  19. Increased adrenocortical response to adrenocorticotropic hormone (ACTH) in sport horses with equine glandular gastric disease (EGGD).

    Science.gov (United States)

    Scheidegger, M D; Gerber, V; Bruckmaier, R M; van der Kolk, J H; Burger, D; Ramseyer, A

    2017-10-01

    This study tested the hypothesis that adrenocortical function would be altered in horses with equine gastric ulcer syndrome (EGUS). Twenty-six sport horses competing at national or international levels in eventing (n=15) or endurance (n=11) were subjected to a gastroscopic examination and an adrenocorticotropic hormone (ACTH) stimulation test. Salivary cortisol concentrations were measured before (baseline) and after (30, 60, 90, 120 and 150min) IV ACTH injection (1μg/kg bodyweight). Within EGUS, two distinct diseases, equine squamous gastric disease (ESGD) and equine glandular gastric disease (EGGD), can be distinguished. ESGD was diagnosed in 8/11 (73%; 95% confidence intervals [95%CI], 43-92%) endurance horses and 5/15 (33%; 95% CI, 14-58%) eventing horses. EGGD was observed in 9/11 (82%; 95% CI, 53-96%) endurance horses and 9/15 (60%; 95% CI, 35-81%) eventing horses. The presence or severity of ESGD was unrelated to the presence or severity of EGGD. ACTH stimulation induced a larger increase in cortisol concentration in horses with moderate EGGD than in horses with mild EGGD. Cortisol concentration during the entire sampling period (total increase in cortisol concentration during the entire sampling period [dAUC], 31.1±6.4ng/mL) and the highest measured concentration at a single time point (maximal increase in cortisol concentration [dMAX], 10.3±2.3ng/mL) were increased (P=0.005 and P=0.038, respectively), indicating that horses with glandular gastric disease exhibited increased adrenocortical responses to ACTH stimulation. These results suggest that EGGD might be associated with an enhanced adrenocortical sensitivity. Further investigations are warranted to confirm the association between adrenocortical sensitivity and EGGD and to elucidate the pathophysiological mechanisms involved. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. PTEN phosphatase-independent maintenance of glandular morphology in a predictive colorectal cancer model system.

    Science.gov (United States)

    Jagan, Ishaan C; Deevi, Ravi K; Fatehullah, Aliya; Topley, Rebecca; Eves, Joshua; Stevenson, Michael; Loughrey, Maurice; Arthur, Kenneth; Campbell, Frederick Charles

    2013-11-01

    Organotypic models may provide mechanistic insight into colorectal cancer (CRC) morphology. Three-dimensional (3D) colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN) coupling of cell division cycle 42 (cdc42) to atypical protein kinase C (aPKC). This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM) orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3) were ineffective. The isolated PTEN C2 domain (C2) accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na(+)/H(+) exchanger regulatory factor-1 (NHERF-1) in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  1. PTEN Phosphatase-Independent Maintenance of Glandular Morphology in a Predictive Colorectal Cancer Model System

    Directory of Open Access Journals (Sweden)

    Ishaan C. Jagan

    2013-11-01

    Full Text Available Organotypic models may provide mechanistic insight into colorectal cancer (CRC morphology. Three-dimensional (3D colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN coupling of cell division cycle 42 (cdc42 to atypical protein kinase C (aPKC. This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3 were ineffective. The isolated PTEN C2 domain (C2 accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na+/H+ exchanger regulatory factor-1 (NHERF-1 in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  2. Correlação dos aspectos laparoscópicos com as alterações histológicas glandulares das lesões endometrióticas peritoneais Correlation between laparoscopic aspects and glandular hystological findings of peritoneal endometriotic lesions

    Directory of Open Access Journals (Sweden)

    Francesco Antonio Viscomi

    2004-09-01

    Full Text Available OBJETIVOS: Correlacionar os aspectos laparoscópicos com os achados histológicos na endometriose peritoneal para facilitar a compreensão da teoria evolutiva da endometriose. MÉTODOS: Foram selecionadas aleatoriamente para o presente estudo prospectivo 67 pacientes submetidas a laparoscopia, com diagnóstico de endometriose peritoneal. A avaliação laparoscópica foi baseada no aspecto visual do implante suspeito de endometriose peritoneal, submetido a estudo anatomopatológico. De acordo com o aspecto laparoscópico, as lesões foram agrupadas em: grupo V - vermelhas, grupo N - negras, grupo B - brancas. A avaliação histológica foi realizada observando-se as características funcionais do epitélio glandular, a presença de debris intraluminais, o número de mitoses e a relação estroma/glândula. RESULTADOS: As características funcionais do epitélio glandular mostraram associação estatisticamente significante entre os grupos, sendo o epitélio com carcterística secretora encontrado em 68,4% das lesões do grupo V, 15,8% do grupo N e B, enquanto que o epitélio incaracterístico foi encontrado em 19,4% das lesões vermelhas, 38,7% das lesões negras e 41,9% das brancas e o epitélio proliferativo foi observado em 50% das pacientes do grupo B e em 25% dos grupos V e N (p=0,011. Em relação à presença de debris intraluminais, também houve diferença significante entre os grupos, estando presentes em 58,4% das lesões negras, 33,3% das lesões brancas e 8,3% das lesões vermelhas (p=0,016. Quanto ao número de mitoses, não houve diferença significante nos três grupos de estudo (p=0,428. O mesmo foi observado na relação estroma/glândula, não havendo diferença significante nos grupos de estudo (p=0,159. CONCLUSÃO: A associação entre atividade funcional nas lesões vermelhas e baixa atividade funcional nas lesões negras e brancas, bem como a presença de debris intraluminais nos diferentes grupos, reforçam a teoria

  3. Minimal effective dose of phosphine to control the cashew root borer, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae Dose mínima efetiva de fosfina no controle da broca-da-raiz do cajueiro, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae

    Directory of Open Access Journals (Sweden)

    Ervino Bleicher

    2010-06-01

    Full Text Available The objective of this research was to determine, in field conditions, the minimal of phosphine effective dose for the cashew root borer control. Three experiments were set up at three different periods: August, October and November, 1994, to control the cashew root borer, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae, in Piaui State, Brazil. One, two, three and six phosphine tablets of three gram each, per plant were tested. In the August essay, phosphine was inefficient to control the borer. In the October essay, control was achieved using as little as 2 tablets per plant and in November with one tablet per plant to control the adult borers in the soil. Higher efficiency was achieved when treatment was applied far away from the last rain, in other words, as soil dries out.Objetivou-se determinar, em condições de campo, a dose mínima de fosfina para o controle da broca da raiz do cajueiro. Foram instalados 3 experimentos em épocas distintas, sendo o primeiro em agosto, o segundo em outubro e o terceiro em novembro de 1994 para o controle de Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae em cajueiro, Anacardium occidentale L. no município de Pio IX, Estado do Piauí. Foram testadas 1; 2; 3 e 6 pastilhas de fosfina na forma de fosfeto de alumínio, de 3 gramas cada, por planta. No ensaio conduzido em agosto nenhum tratamento foi eficiente para o controle de brocas adultas no solo. No ensaio instalado em outubro, a fosfina foi eficiente a partir de duas pastilhas por planta e no ensaio de novembro a partir de uma pastilha por planta para o controle de adultos no solo. A eficiência foi tanto maior quanto maior foi o tempo decorrido após a última chuva, estando, portanto, o solo mais seco.

  4. Dual-energy digital mammography: Calibration and inverse-mapping techniques to estimate calcification thickness and glandular-tissue ratio

    International Nuclear Information System (INIS)

    Kappadath, S. Cheenu; Shaw, Chris C.

    2003-01-01

    Breast cancer may manifest as microcalcifications in x-ray mammography. Small microcalcifications, essential to the early detection of breast cancer, are often obscured by overlapping tissue structures. Dual-energy imaging, where separate low- and high-energy images are acquired and synthesized to cancel the tissue structures, may improve the ability to detect and visualize microcalcifications. Transmission measurements at two different kVp values were made on breast-tissue-equivalent materials under narrow-beam geometry using an indirect flat-panel mammographic imager. The imaging scenario consisted of variable aluminum thickness (to simulate calcifications) and variable glandular ratio (defined as the ratio of the glandular-tissue thickness to the total tissue thickness) for a fixed total tissue thickness--the clinical situation of microcalcification imaging with varying tissue composition under breast compression. The coefficients of the inverse-mapping functions used to determine material composition from dual-energy measurements were calculated by a least-squares analysis. The linear function poorly modeled both the aluminum thickness and the glandular ratio. The inverse-mapping functions were found to vary as analytic functions of second (conic) or third (cubic) order. By comparing the model predictions with the calibration values, the root-mean-square residuals for both the cubic and the conic functions were ∼50 μm for the aluminum thickness and ∼0.05 for the glandular ratio

  5. Glandular trichome density and essential oil composition in leaves and inflorescences of Lippia origanoides Kunth (Verbenaceae in the Brazilian Cerrado

    Directory of Open Access Journals (Sweden)

    Luiz R.S. Tozin

    2015-06-01

    Full Text Available The essential oils from leaves and inflorescences of Lippia origanoides Kunth present aromatic and medicinal potential and have been used to treat several diseases, including melanoma. In Brazil, L. origanoides is commonly found in campo cerrado and cerrado stricto sensu, physiognomies featured mainly by the differential light conditions to which short and medium-sized plants are subjected. Our aim was to investigate the glandular trichome density and the yield and chemical composition of the essential oils in leaves and inflorescences of L. origanoides from campo cerrado and cerrado stricto sensu. For glandular density analysis, leaves and inflorescences were processed according to conventional techniques for scanning electron microscopy. The essential oils of leaves and inflorescences were obtained by hydrodistillation and identified with gas chromatography. Bracts and sepals showed the highest glandular density, followed by petals and leaves. The glandular density in the abaxial leaf surface was higher in individuals from the campo cerrado. In both populations the essential oil yield was higher in inflorescences than in leaves. The chemical composition of the essential oils varied among individuals from different areas and inside a same population. Our results demonstrated the chemical plasticity of L. origanoides suggesting the importance of monitoring its popular use.

  6. Detection of cervical intraepithelial neoplasia in women with atypical squamous or glandular cells of undetermined significance cytology: a prospective study

    NARCIS (Netherlands)

    Wensveen, Celesta; Kagie, Marjolein; Veldhuizen, Roel; de Groot, Christianne; Denny, Lynette; Zwinderman, Koos; Trimbos, Baptist

    2003-01-01

    (1) To assess the prevalence of histologically confirmed cervical intraepithelial neoplasia in patients with cervical smears diagnosed as atypical squamous or glandular cells of undetermined significance. (2) To evaluate the role of colposcopy and the presence of human papillomavirus in detecting

  7. Monte Carlo simulation studies for the determination of microcalcification thickness and glandular ratio through dual-energy mammography

    Science.gov (United States)

    Del Lama, L. S.; Godeli, J.; Poletti, M. E.

    2017-08-01

    The majority of breast carcinomas can be associated to the presence of calcifications before the development of a mass. However, the overlapping tissues can obscure the visualization of microcalcification clusters due to the reduced contrast-noise ratio (CNR). In order to overcome this complication, one potential solution is the use of the dual-energy (DE) technique, in which two different images are acquired at low (LE) and high (HE) energies or kVp to highlight specific lesions or cancel out tissue background. In this work, the DE features were computationally studied considering simulated acquisitions from a modified PENELOPE Monte Carlo code. The employed irradiation geometry considered typical distances used in digital mammography, a CsI detection system and an updated breast model composed of skin, microcalcifications and glandular and adipose tissues. The breast thickness ranged from 2 to 6 cm with glandularities of 25%, 50% and 75%, where microcalcifications with dimensions from 100 up to 600 μm were positioned. In general, results pointed an efficiency index better than 87% for the microcalcification thicknesses and better than 95% for the glandular ratio. The simulations evaluated in this work can be used to optimize the elements from the DE imaging chain, in order to become a complementary tool for the conventional single-exposure images, especially for the visualization and estimation of calcification thicknesses and glandular ratios.

  8. Glandular trichome density and essential oil composition in leaves and inflorescences of Lippia origanoides Kunth (Verbenaceae) in the Brazilian Cerrado.

    Science.gov (United States)

    Tozin, Luiz R S; Marques, Marcia O M; Rodrigues, Tatiane M

    2015-01-01

    The essential oils from leaves and inflorescences of Lippia origanoides Kunth present aromatic and medicinal potential and have been used to treat several diseases, including melanoma. In Brazil, L. origanoides is commonly found in campo cerrado and cerrado stricto sensu, physiognomies featured mainly by the differential light conditions to which short and medium-sized plants are subjected. Our aim was to investigate the glandular trichome density and the yield and chemical composition of the essential oils in leaves and inflorescences of L. origanoides from campo cerrado and cerrado stricto sensu. For glandular density analysis, leaves and inflorescences were processed according to conventional techniques for scanning electron microscopy. The essential oils of leaves and inflorescences were obtained by hydrodistillation and identified with gas chromatography. Bracts and sepals showed the highest glandular density, followed by petals and leaves. The glandular density in the abaxial leaf surface was higher in individuals from the campo cerrado. In both populations the essential oil yield was higher in inflorescences than in leaves. The chemical composition of the essential oils varied among individuals from different areas and inside a same population. Our results demonstrated the chemical plasticity of L. origanoides suggesting the importance of monitoring its popular use.

  9. Abnormal ion content, hydration and granule expansion of the secretory granules from cystic fibrosis airway glandular cells

    International Nuclear Information System (INIS)

    Baconnais, S.; Delavoie, F.; Zahm, J.M.; Milliot, M.; Terryn, C.; Castillon, N.; Banchet, V.; Michel, J.; Danos, O.; Merten, M.; Chinet, T.; Zierold, K.; Bonnet, N.; Puchelle, E.; Balossier, G.

    2005-01-01

    The absence or decreased expression of cystic fibrosis transmembrane conductance regulator (CFTR) induces increased Na + absorption and hyperabsorption of the airway surface liquid (ASL) resulting in a dehydrated and hyperviscous ASL. Although the implication of abnormal airway submucosal gland function has been suggested, the ion and water content in the Cystic Fibrosis (CF) glandular secretory granules, before exocytosis, is unknown. We analyzed, in non-CF and CF human airway glandular cell lines (MM-39 and KM4, respectively), the ion content in the secretory granules by electron probe X-ray microanalysis and the water content by quantitative dark field imaging on freeze-dried cryosections. We demonstrated that the ion content (Na + , Mg 2+ , P, S and Cl - ) is significantly higher and the water content significantly lower in secretory granules from the CF cell line compared to the non-CF cell line. Using videomicroscopy, we observed that the secretory granule expansion was deficient in CF glandular cells. Transfection of CF cells with CFTR cDNA or inhibition of non-CF cells with CFTR inh -172, respectively restored or decreased the water content and granule expansion, in parallel with changes in ion content. We hypothesize that the decreased water and increased ion content in glandular secretory granules may contribute to the dehydration and increased viscosity of the ASL in CF

  10. Ulceração das placas psoriáticas - efeito cutâneo adverso do metotrexato em altas doses no tratamento da psoríase: relato de três casos

    Directory of Open Access Journals (Sweden)

    Ataíde Deborah Skusa de Torre

    2003-01-01

    Full Text Available Os autores relatam três casos de pacientes portadores de psoríase que utilizaram inadvertidamente doses elevadas de metotrexato e apresentaram ulceração das lesões cutâneas de psoríase. Os efeitos adversos cutâneos do metotrexato são raros, algumas vezes dose-dependentes, outras idiossincrásicos ou relacionados com alteração de metabolização da droga, ou, ainda, interações medicamentosas

  11. Índice orientador do tratamento sistêmico da gravidez ectópica íntegra com dose única de metotrexato Index for the systemic treatment of unruptured ectopic pregnancy with a single dose of methotrexate

    Directory of Open Access Journals (Sweden)

    Julio Elito Junior

    1998-04-01

    Full Text Available Foi realizado estudo longitudinal em 42 pacientes com diagnóstico de gravidez ectópica íntegra, com o intuito de se elaborar um índice orientador do uso sistêmico de metotrexato em dose única (50 mg/m² por via intramuscular. O acompanhamento se fez através de dosagens de beta-hCG (fração beta do hormônio gonadotrópico coriônico realizadas no 1º, 4º e 7º dias após o emprego do quimioterápico. Quando ocorreu queda de 15% ou mais nos títulos de beta-hCG, apurados no 4º e no 7º dia, as pacientes receberam alta hospitalar e seguimento ambulatorial com dosagens semanais de beta-hCG até que se atingissem níveis inferiores a 5 mUI/ml. Foi elaborado um índice orientador do tratamento sistêmico com metotrexato baseado nos seguintes parâmetros: (1 valores iniciais de beta-hCG; (2 aspecto da imagem à ultra-sonografia (hematossalpinge, anel tubário, embrião vivo; (3 maior diâmetro da massa anexial; (4 quantidade de líquido livre; (5 fluxo vascular medido por meio do doppler colorido. Cada parâmetro recebeu pontuação de 0 a 2. A nota zero significa elemento de mau prognóstico, a nota dois indica parâmetros favoráveis e a nota um, situações intermediárias. O índice de sucesso com dose única foi de 69,0% (29/42 pacientes. A ultra-sonografia transvaginal com doppler colorido foi realizada em 20 das 42 pacientes do estudo. Neste grupo de 20 pacientes o sucesso do tratamento ocorreu em 75,0% dos casos (15/20. Entre as 22 pacientes que não foram avaliadas com doppler colorido a média das notas do índice nos casos de sucesso foi de 6,6, nas de insucesso 3,1. No grupo de pacientes avaliadas por doppler (20 pacientes as médias foram de 7,9 (sucesso e 4,2 (fracasso. No presente estudo a nota de corte foi estabelecida levando-se em conta o valor abaixo do qual o tratamento não foi efetivo e correspondeu a cinco, pois 93,75% das pacientes com nota superior a 5 evoluíram com sucesso (15/16, ao passo que notas inferiores ou

  12. Cervical squamous and glandular intraepithelial neoplasia: identification and current management approaches Neoplasia intraepitelial cervical escamosa y glandular: identificación y estrategias de manejo

    Directory of Open Access Journals (Sweden)

    V Cecil Wright

    2003-01-01

    realiza mediante la biopsia de cono, y el espécimen debe tener márgenes negativos para enfermedad. La histerectomía es un tratamiento probable, a menos que la fertilidad esté siendo buscada. La escisión, particularmente por electrocirugía (loop, puede interferir con la interpretación histológica en algunos casos o de ambos, particularmente en enfermedades escamosas y adenocarcinoma in situ. En este artículo se describe ampliamente el manejo de la neoplasia intraepitelial escamosa y glandular.

  13. Differentiating between endocervical glandular neoplasia and high grade squamous intraepithelial lesions in endocervical crypts: cytological features in ThinPrep and SurePath cervical cytology samples.

    Science.gov (United States)

    Thiryayi, Sakinah A; Marshall, Janet; Rana, Durgesh N

    2009-05-01

    A recent audit at our institution revealed a higher number of cases diagnosed as endocervical glandular neoplasia on ThinPrep (TP) cervical cytology samples (9 cases) as opposed to SurePath (SP) (1 case), which on histology showed only high-grade cervical intraepithelial neoplasia (CIN) with endocervical crypt involvement (CI). We attempted to ascertain the reasons for this finding by reviewing the available slides of these cases, as well as slides of cases diagnosed as glandular neoplasia on cytology and histology; cases diagnosed as high-grade squamous intraepithelial lesions (HSIL) on cytology which had CIN with CI on histology and cases with mixed glandular and squamous abnormalities diagnosed both cytologically and histologically. Single neoplastic glandular cells and short pseudostratified strips were more prevalent in SP than TP with the cell clusters in glandular neoplasia 3-4 cells thick, in contrast to the dense crowded centre of cell groups in HSIL with CI. The cells at the periphery of groups can be misleading. Cases with HSIL and glandular neoplasia have a combination of the features of each entity in isolation. The diagnosis of glandular neoplasia remains challenging and conversion from conventional to liquid based cervical cytology requires a period of learning and adaptation, which can be facilitated by local audit and review of the cytology slides in cases with a cytology-histology mismatch. (c) 2009 Wiley-Liss, Inc.

  14. Doses de boro e crescimento radicular e da parte aérea de cultivares de arroz de terras altas Influence of boron addition on growth of roots and shoot of upland rice crops

    Directory of Open Access Journals (Sweden)

    Juliano Corulli Corrêa

    2006-12-01

    Full Text Available O crescimento radicular é favorecido em condições adequadas de disponibilidade de boro no solo e, por isto, a aplicação da dose correta desse micronutriente é de grande importância, para que não ocorra prejuízo no desenvolvimento e na produtividade da cultura de arroz de terras altas, de acordo com a variedade e tipo de solo. O presente trabalho teve como objetivo avaliar a influência das doses de boro no crescimento radicular e da parte aérea, em três cultivares de arroz de terras altas. O experimento foi realizado em casa de vegetação, em vaso com capacidade de 10 L, que continha 8 dm³ de solo Latossolo Vermelho distrófico, sendo o delineamento experimental inteiramente casualizado, em esquema fatorial 3 x 3, com quatro repetições. Os tratamentos consistiram de três cultivares (Caiapó, Primavera e Maravilha e três doses de boro (0, 3 e 6 mg dm-3, usando, como fonte, o bórax. A dose de 6 mg dm-3 foi prejudicial tanto à produção de matéria seca da parte aérea como de raiz para o arroz de terras altas. Além de apresentar maior capacidade de absorção de boro, o cultivar Maravilha apresentou-se mais tolerante à elevação da disponibilidade de B no solo, não ocorrendo alterações de comprimento, diâmetro e superfície radicular.Appropriate boron (B availability in soils favors root growth, and a sufficient supply of this micronutrient is very important for adequate rice development and yield in upland fields, depending on the cultivars and soil type. This study aimed at evaluating the influence of B addition on growth of roots and shoot of three upland rice cultivars. The experiment was carried out in a greenhouse, in 10 L pots containing 8 kg of an Hapludox; the experiment was in a completely random 3 x 3 factorial design, with four replications. The treatments consisted of three rice cultivars (Caiapó, Primavera, and Maravilha and three B rates (0, 3 and 6 mg dm-3, as borax. The B rate of 6 mg dm-3 boron was

  15. Identification, functional characterization and developmental regulation of sesquiterpene synthases from sunflower capitate glandular trichomes

    Directory of Open Access Journals (Sweden)

    Ro Dae-Kyun

    2009-07-01

    Full Text Available Abstract Background Sesquiterpene lactones are characteristic metabolites of Asteraceae (or Compositae which often display potent bioactivities and are sequestered in specialized organs such as laticifers, resin ducts, and trichomes. For characterization of sunflower sesquiterpene synthases we employed a simple method to isolate pure trichomes from anther appendages which facilitated the identification of these genes and investigation of their enzymatic functions and expression patterns during trichome development. Results Glandular trichomes of sunflower (Helianthus annuus L. were isolated, and their RNA was extracted to investigate the initial steps of sesquiterpene lactone biosynthesis. Reverse transcription-PCR experiments led to the identification of three sesquiterpene synthases. By combination of in vitro and in vivo characterization of sesquiterpene synthase gene products in Escherichia coli and Saccharomyces cerevisiae, respectively, two enzymes were identified as germacrene A synthases, the key enzymes of sesquiterpene lactone biosynthesis. Due to the very low in vitro activity, the third enzyme was expressed in vivo in yeast as a thioredoxin-fusion protein for functional characterization. In in vivo assays, it was identified as a multiproduct enzyme with the volatile sesquiterpene hydrocarbon δ-cadinene as one of the two main products with α-muuorlene, β-caryophyllene, α-humulene and α-copaene as minor products. The second main compound remained unidentified. For expression studies, glandular trichomes from the anther appendages of sunflower florets were isolated in particular developmental stages from the pre- to the post-secretory phase. All three sesquiterpene synthases were solely upregulated during the biosynthetically active stages of the trichomes. Expression in different aerial plant parts coincided with occurrence and maturity of trichomes. Young roots with root hairs showed expression of the sesquiterpene synthase genes

  16. Doses in mammography. Preliminary study

    International Nuclear Information System (INIS)

    Marquez P, F.; Acosta R, N.; Universidad Nacional Mayor de San Marcos, Lima; Benavente, T.; Universidad Nacional Mayor de San Marcos, Lima; Poma, M.

    2002-01-01

    Mammography is the most important method to detect lesions in the breast with this technique one can detect small tumours before clear clinical symptoms appear. Mammographic image of require high quality standards due that the extremely low contrast between the normal and pathological areas in the breast, eg.g., they have similar attenuation and absorption coefficient. The x-ray mammographic systems, used in this study are Senographe 500t and Senographe DMR, a detector with a RadCal ionization chambers calibrated to the qualities of mammographic x-ray beams, and a breast simulator that is a phantoms of polymethylmethacrylate (PMMA) of several thicknesses with the equivalence of 50% of the glandular tissue. The results obtained indicate that the values of doses at the entrance surface of a breast (DES) are greater the reference value 20 mGy to 5,0 cm of PMMA and the values of the mean glandular dose (MGD) exceed the reference value of 2,1 mGy for 5,1 cm of compressed thick breast. We consider that the values high of the EDS and MGD are due that the x-ray systems no meeting in good condition or for used of x-ray spectra no suitable, so is recommendable be carried out test of quality control to the x-ray systems and also realize studies, or characterize the of x-ray mammographic spectra

  17. Estudo da circulação hepatomesentérica pela angiografia por ressonância magnética com gadolínio: comparação entre doses simples e dupla no estudo de pacientes esquistossomóticos Gadolinium-enhanced magnetic resonance angiography for hepatomesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients

    Directory of Open Access Journals (Sweden)

    Rogério Pedreschi Caldana

    2006-08-01

    Full Text Available OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla. MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA em 21 pacientes e dose simples (0,1 mmol/kg em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p OBJECTIVE: To evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses. MATERIALS AND METHODS: A prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T, with body coil and power injector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg and

  18. Células glandulares atípicas e câncer de colo uterino: revisão sistemática Atypical glandular cells and cervical cancer: systematic review

    Directory of Open Access Journals (Sweden)

    Juliana Pedrosa de Holanda Marques

    2011-04-01

    Full Text Available Atipias de células glandulares em esfregaços cervicovaginais é um achado citológico na rotina de rastreamento do câncer cervical, que aumentou nas últimas décadas. Sua constatação é importante clinicamente, pois é alta a percentagem de casos associados com doença cervical e endometrial de alto grau e câncer. Este trabalho avaliou, por meio de uma revisão sistemática, estudos que investigaram o perfil das lesões de colo uterino em avaliações histológicas de seguimento de pacientes já diagnosticadas com células glandulares atípicas. Foram excluídos os estudos cuja investigação diagnóstica não incluísse o diagnóstico histopatológico. Realizou-se uma busca abrangente de publicações no período de 1966 a 2009, nas bases do LILACS, SciELO, PubMed/Medline e Old Medline. Os artigos omitidos na busca eletrônica também foram incluídos. Estavam de acordo com os critérios de inclusão 19 artigos, que foram selecionados. Este estudo tem como objetivo avaliar se a atipia celular glandular observada inicialmente na citologia relacionava-se histologicamente com a presença de lesões benignas, pré-neoplásicas ou neoplásicas. Dos 19 estudos selecionados, 11 mostraram maior correlação entre atipia glandular com patologias benignas e seis com lesões escamosas pré-malignas.Atypical glandular cells are a common finding in cervical cytology in cervical cancer screening and its occurrence has increased in the last decades. The identification of these cells is clinically very important due to its association with cervical and endometrial dysplasic lesions and cancer. Using a systematic approach, this article reviewed studies investigating cervical lesions that are characteristic in patients previously diagnosed as having atypical glandular cells. Studies in which diagnostic investigation did not include histopathological diagnosis were excluded. A comprehensive search for available material in LILACS, SciELO, PubMed/ Medline

  19. Variabilidade clínica na determinação da dose tóxica oral em intoxicação experimental por fluoroacetato de sódio em gatos

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Collicchio-Zuanaze

    2006-02-01

    Full Text Available O fluoroacetato de sódio (FAS ou composto 1080 é um potente rodenticida utilizado no controle de roedores e predadores mamíferos. Sua utilização está proibida por lei em diversos países devido à sua alta toxicidade, mas no Brasil há evidências do uso ilegal e sem critérios causando intoxicações, principalmente em crianças e animais domésticos. O FAS age por meio do seu metabólito tóxico, o fluorocitrato, no bloqueio do ciclo de Krebs com conseqënte diminuição da produção de energia do organismo, provocando principalmente manifestações clínicas neurológicas e cardíacas. No presente estudo compararam quatro doses orais tóxicas do fluoroacetato de sódio, descritas em gatos, na literatura, observando-se o aparecimento dos sinais clínicos predominantes da intoxicação, as diferenças entre as doses quanto a variabilidade clínica em relação ao período de latência para o aparecimento dos sinais clínicos e sua respectiva intensidade. A dose oral tóxica que melhor caracterizou o quadro clínico da intoxicação por FAS em gatos, sem causar a letalidade aguda, foi de 0,45mg/kg. As diferenças entre as manifestações clínicas foram dose-dependentes e em ordem crescente de intensidade, caracterizando-se como sinais leves (dose 1: 0,3mg/kg, leves a moderados (dose 2: 0,4mg/kg, moderados a graves (dose 3: 0,45mg/kg e graves (dose 4: 0,5mg/kg. Houve também variabilidade clínica individual entre animais intoxicados com a mesma dosagem do tóxico.

  20. Dose estimative in operators during petroleum wells logging with nuclear wireless probes through computer modelling; Estimativa da dose em operadores durante procedimentos de perfilagem de pocos de petroleo com sondas wireless nucleares atraves de modelagem computacional

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo T., E-mail: emonteiro@nuclear.ufrj.b, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Lima, Inaya C.B., E-mail: inaya@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Instituto Politecnico do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil); Correa, Samanda Cristine Arruda, E-mail: scorrea@cnen.gov.b [Comissao Nacional de Energia Nuclear (DIAPI/CGMI/CNEN), Rio de Janeiro, RJ (Brazil); Rocha, Paula L.F., E-mail: ferrucio@acd.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ)., RJ (Brazil). Dept. de Geologia

    2011-10-26

    This paper evaluates the absorbed dose and the effective dose on operators during the petroleum well logging with nuclear wireless that uses gamma radiation sources. To obtain the data, a typical scenery of a logging procedure will be simulated with MCNPX Monte Carlo code. The simulated logging probe was the Density Gamma Probe - TRISOND produced by Robertson Geolloging. The absorbed dose values were estimated through the anthropomorphic simulator in male voxel MAX. The effective dose values were obtained using the ICRP 103

  1. Efeito de doses de metribuzin no crescimento e na conversão da energia solar em plantas de soja (Glycine max (L . merrill Effect of metribuzin doses on the growth and solar energy conversion in soybean (Glycine max (L. merrill plants

    Directory of Open Access Journals (Sweden)

    P. J. Silva Neto

    1991-01-01

    Full Text Available O crescimento e a eficiência na conversão da energia solar foram estudados em soja (Glycine max (L. Merri ll, cv. 'Uberaba', cultivada em condições de campo, sob quatro doses de metribuzin (0, 0,35; 0,70 e 1,05 kg i.a.ha-1. O valor máximo da conversão da energia solar foi de 0,75%, para as plantas cultiva das na maior dose do herbicida. Os valores da conversão da energia solar média durante o ciclo da cultura foram 0,32 ; 0,31 ; 0,32 e 0,33%. em ordem crescente de dose do metribuzin. De modo geral, na fase vegetativa as plantas controle apresentaram valores inferiores em todos os valores de crescimento determinados, superando as tratadas com metribuzin somente na fase reprodutiva, mostrando que no período crítico de competição o dano causado pelas plantas daninhas é maior que a possível fitotoxicida de causada pelo metribuzin.Growth analysis and evaluation of solar energy conversion in soybean (Glycine max (L. Merrill, Uberaba unver field conditions and four doses of metribuzin (0,0;0,35; 0,70 and 1,05 kg i.a.ha-1 were performed in this study. Maximum solar energy conversion was 0,75% for pla nts tre ate d wit h 1,05 kg i.a.ha -1 metribuzin. The aver age of solar energy conversion throughout the entire crop cycle were 0,32, 0,31 , 0,32 and 0,33% for the increasing metribuzin doses. In general, the control showed lower figures for all growth values studied than the treated during the vegetative phase. During the reproductive phase, however, they surpassed those tre ated with metribuzin, showing that in the critical period of competition weeds were more harmful than the phytotoxicity produced by metribuzin.

  2. Volatiles and Nonvolatiles in Flourensia campestris Griseb. (Asteraceae), How Much Do Capitate Glandular Trichomes Matter?

    Science.gov (United States)

    Piazza, Leonardo A; López, Daniela; Silva, Mariana P; López Rivilli, Marisa J; Tourn, Mónica G; Cantero, Juan J; Scopel, Ana L

    2018-03-01

    The distribution and ultrastructure of capitate glandular trichomes (GTs) in Flourensia species (Asteraceae) have been recently elucidated, but their metabolic activity and potential biological function remain unexplored. Selective nonvolatile metabolites from isolated GTs were strikingly similar to those found on leaf surfaces. The phytotoxic allelochemical sesquiterpene (-)-hamanasic acid A ((-)-HAA) was the major constituent (ca. 40%) in GTs. Although GTs are quaternary ammonium compounds (QACs)-accumulating species, glycine betaine was not found in GTs; it was only present in the leaf mesophyll. Two (-)-HAA accompanying surface secreted products: compounds 4-hydroxyacetophenone (piceol; 1) and 2-hydroxy-5-methoxyacetophenone (2), which were isolated and fully characterized (GC/MS, NMR), were present in the volatiles found in GTs. The essential oils of fresh leaves revealed ca. 33% monoterpenes, 26% hydrocarbon- and 30% oxygenated sesquiterpenes, most of them related to cadinene and bisabolene derivatives. Present results suggest a main role of GTs in determining the volatile and nonvolatile composition of F. campestris leaves. Based on the known activities of the compounds identified, it can be suggested that GTs in F. campestris would play key ecological functions in plant-pathogen and plant-plant interactions. In addition, the strikingly high contribution of compounds derived from cadinene and bisabolene pathways, highlights the potential of this species as a source of high-valued bioproducts. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  3. 20-year Follow-up of Recurrent Glandular Odontogenic Cyst Mimicking a Periapical Lesion.

    Science.gov (United States)

    de Freitas Silva, Brunno Santos; Yamamoto-Silva, Fernanda Paula; Sena-Filho, Marcondes; Silva Sant'Ana, Simone Sousa; Mariano-Júnior, Wilson José; de Almeida, Oslei Paes; Estrela, Carlos

    2017-11-01

    Periapical lesions usually are caused by root canal infection; nevertheless, other pathologies may eventually involve the tooth apex, making the correct diagnosis more difficult. Glandular odontogenic cysts (GOCs) are uncommon and, despite their cystic nature, may present an aggressive behavior and a high recurrence rate. This report describes a recurrent GOC mimicking a periapical lesion that was followed up for 20 years. A 45-year-old woman described tooth discomfort for several years in the anterior region of the mandible that was not exacerbated during eating or occlusion. Clinical examination revealed no signs of swelling, redness, or inflammation in the gingival or surrounding soft tissue. Nevertheless, periapical radiography showed a well-defined large radiolucent lesion in the periapical region of teeth #22, #23, #24, and #25. The pulp test confirmed that all these teeth were vital. An incisional biopsy was performed, and with the histopathological diagnosis of an odontogenic cyst, the lesion was enucleated surgically. After recurrence, the extensive periapical multilocular lesions were again surgically removed. Based on the microscopic findings, the final diagnosis was GOC. One year later, there were no signs of recurrence. GOCs associated with the root apex may mimic periapical inflammatory diseases. Clinical, radiographic, and histopathological findings are essential for the diagnosis of inconclusive radiolucent findings in the periapical region. Biopsy specimens should be sent to a specialized oral pathology laboratory. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Glandular odontogenic cyst mimicking ameloblastoma in a 78 year old female: A case report

    International Nuclear Information System (INIS)

    Lee, Byung Do; Lee, Wan; Kwon, Kyung Hwan; Choi, Moon Ki; Choi, Eun Joo; Yoon, Jung Hoon

    2014-01-01

    Glandular odontogenic cyst (GOC) is a rare, potentially aggressive jaw lesion. The common radiographic features include a well-defined radiolucency with distinct borders, presenting a uni- or multilocular appearance. A cystic lesion in the posterior mandible of a 78-year-old female was incidentally found. Radiographs showed a unilocular lesion with a scalloped margin, external root resorption of the adjacent tooth, and cortical perforation. This lesion had changed from a small ovoid shape to a more expanded lesion in a period of four years. The small lesion showed unilocularity with a smooth margin and a well-defined border, but the expanded lesion produced cortical perforation and a lobulated margin. The provisional diagnosis was an ameloblastoma, whereas the histopathological examination revealed a GOC. This was a quite rare case, given that this radiographic change was observed in the posterior mandible of an elderly female. This case showed that a GOC can grow even in people in their seventies, changing from the unilocular form to an expanded, lobulated lesion. Here, we report a case of GOC with characteristic radiographic features.

  5. Glandular odontogenic cyst mimicking ameloblastoma in a 78 year old female: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Do; Lee, Wan; Kwon, Kyung Hwan; Choi, Moon Ki; Choi, Eun Joo [College of Dentistry, Wonkwang University, Iksan (Korea, Republic of); Yoon, Jung Hoon [Dept. of Oral and Maxillofacial Pathology, College of Dentistry, Daejeon Dental Hospital, Wonkwang University, Daejeon (Korea, Republic of)

    2014-09-15

    Glandular odontogenic cyst (GOC) is a rare, potentially aggressive jaw lesion. The common radiographic features include a well-defined radiolucency with distinct borders, presenting a uni- or multilocular appearance. A cystic lesion in the posterior mandible of a 78-year-old female was incidentally found. Radiographs showed a unilocular lesion with a scalloped margin, external root resorption of the adjacent tooth, and cortical perforation. This lesion had changed from a small ovoid shape to a more expanded lesion in a period of four years. The small lesion showed unilocularity with a smooth margin and a well-defined border, but the expanded lesion produced cortical perforation and a lobulated margin. The provisional diagnosis was an ameloblastoma, whereas the histopathological examination revealed a GOC. This was a quite rare case, given that this radiographic change was observed in the posterior mandible of an elderly female. This case showed that a GOC can grow even in people in their seventies, changing from the unilocular form to an expanded, lobulated lesion. Here, we report a case of GOC with characteristic radiographic features.

  6. Verificação do fator de calibração e indicador da qualidade do feixe de aceleradores lineares Verification of dose output and beam quality indicator in linear accelerators

    Directory of Open Access Journals (Sweden)

    Maria da Penha Silva

    2001-10-01

    Full Text Available Um programa de garantia da qualidade é um pré-requisito obrigatório para a exatidão necessária em radioterapia. Este trabalho relata parte dos testes de rotina mensal do controle da qualidade dos aceleradores lineares do Instituto Nacional do Câncer, relativos à calibração dos feixes de fótons e elétrons, no período de dois anos. Os resultados foram comparados com as recomendações do protocolo AAPM TG-40. Na análise do fator de calibração para o feixe de fótons foi encontrado um desvio máximo de 12%; para o feixe de elétrons o maior desvio encontrado foi 10%. A flutuação observada no indicador da qualidade do feixe para os feixes de elétrons foi maior que para os feixes de fótons. Os resultados confirmam a importância de um programa de garantia da qualidade em um serviço de radioterapia, permitindo correções rápidas da dose administrada ao paciente.A quality assurance program is a mandatory prerequisite for obtaining the high level of accuracy required for radiotherapy. This paper reports the results of part of the routine quality control tests for linear accelerators at the National Cancer Institute, Brazil, performed monthly over a period of two years. These tests included dose output and beam quality indicator. The results were compared with the guidelines of the AAPM TG-40 protocol. The results for the photon beams have shown dose output variations of up to 12%; for electron beams, the largest deviation found was 10%. The fluctuations observed in the beam quality indicator for the electron beams were greater than for the photon beams. These results strongly emphasize the importance of a quality assurance program in radiotherapy services in order to allow prompt corrections of the dose delivered to the patient.

  7. [Treatment of gynecomastia by a combined method of liposuction and semicircular periareolar incision glandular organ partial resection].

    Science.gov (United States)

    Liu, Su; Kuang, Ruixia; Chen, Zhenyu; Li, Huichao; Zhang, Weina; Wang, Zhiguo; Miao, Yuanxin; Chen, Lu

    2008-12-01

    To evaluate the effect of the combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia. From June 2004 to June 2006, 40 patients, aged 11-41 years old, were treated, with no-nodule (n = 10), nodule (n = 22) and female-breast-like with nodules (n = 8). Three patients were unilateral and 37 ones were bilateral. The levels of serum prolactin, luteinizing hormone, follicle stimulating hormone, estradiol, testosterone and cortisol were normal in 38 patients, while in the other 2 patients, the levels of serum prolactin, luteinizing hormone, follicle stimulating hormone and estradiol were higher than normal, and the testosterone level was lower. Liposuction alone was performed in 10 no-nodule patients (lipo-type), and combined liposuction and semicircular periareolar incision glandular organ partial resection were conducted in the other 30 patients (lipo-glandular type). RESULTS; Except for 2 cases in which hematoma and a small amount of effusion were found on the first and second day postoperatively and then obtained healing by first intention right after hematoma removal in time, all the other patients incisions obtained healing by first intention. Nipple numbness occurred in 3 cases on the first day postoperatively and no special treatment was conducted. There was still nipple hypesthesia in these 3 cases after 6-month follow-up. There were no complications such as hematoma, effusion, nipple and mammary areola necrosis, and nipple hypesthesia in other patients. All the 40 patients were followed up for 6-24 months (13 months on average). They were satisfied with their chest figures and no recurrence was observed. The combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia has many advantages, such as safe, micro-scars, natural and beautiflhl male breast figures as well as high patients' satisfaction.

  8. Fibroblast growth factor 10-fibroblast growth factor receptor 2b mediated signaling is not required for adult glandular stomach homeostasis.

    Directory of Open Access Journals (Sweden)

    Allison L Speer

    Full Text Available The signaling pathways that are essential for gastric organogenesis have been studied in some detail; however, those that regulate the maintenance of the gastric epithelium during adult homeostasis remain unclear. In this study, we investigated the role of Fibroblast growth factor 10 (FGF10 and its main receptor, Fibroblast growth factor receptor 2b (FGFR2b, in adult glandular stomach homeostasis. We first showed that mouse adult glandular stomach expressed Fgf10, its receptors, Fgfr1b and Fgfr2b, and most of the other FGFR2b ligands (Fgf1, Fgf7, Fgf22 except for Fgf3 and Fgf20. Fgf10 expression was mesenchymal whereas FGFR1 and FGFR2 expression were mostly epithelial. Studying double transgenic mice that allow inducible overexpression of Fgf10 in adult mice, we showed that Fgf10 overexpression in normal adult glandular stomach increased epithelial proliferation, drove mucous neck cell differentiation, and reduced parietal and chief cell differentiation. Although a similar phenotype can be associated with the development of metaplasia, we found that Fgf10 overexpression for a short duration does not cause metaplasia. Finally, investigating double transgenic mice that allow the expression of a soluble form of Fgfr2b, FGF10's main receptor, which acts as a dominant negative, we found no significant changes in gastric epithelial proliferation or differentiation in the mutants. Our work provides evidence, for the first time, that the FGF10-FGFR2b signaling pathway is not required for epithelial proliferation and differentiation during adult glandular stomach homeostasis.

  9. CINtec PLUS immunocytochemistry as a tool for the cytologic diagnosis of glandular lesions of the cervix uteri.

    Science.gov (United States)

    Ravarino, Alberto; Nemolato, Sonia; Macciocu, Elena; Fraschini, Matteo; Senes, Giancarlo; Faa, Gavino; Negri, Giovanni

    2012-11-01

    Cytologic findings of glandular lesions of the cervix uteri are often difficult to evaluate. We studied the usefulness of CINtec PLUS p16/Ki-67 double stain (mtm laboratories, Heidelberg, Germany) for the diagnosis of glandular lesions. The study included 47 abnormal results on liquid-based cytologic tests with a subsequent histologic diagnosis of adenocarcinoma in situ or with early invasion, and 16 samples with negative results on follow-up. All samples were stained with CINtec PLUS p16/Ki-67 double stain. Of the neoplastic samples, 7 were excluded because of insufficient residual cellularity or loss of neoplastic cells. Of the samples that were adequate, 92.5% were stained with CINtec PLUS, whereas 7.5% were judged inconclusive. All inconclusive cases were at least 3 years old. Of the 16 negative samples, 15 (93.8%) stained negative and only 1 (6.2%) showed several positive clusters of cells. Our study shows that CINtec PLUS is a robust and useful tool for the diagnosis of glandular lesions of the cervix uteri.

  10. [Markers of stromal invasion during background and precancerous changes of the glandular epithelium and in adenocarcinoma of the cervix uteri].

    Science.gov (United States)

    Danilova, N V; Andreeva, Iu Iu; Zavalishina, L É; Mal'kov, P G

    2012-01-01

    It is very difficult to identify stromal invasion when the glandular epithelium of the cervix uteri is involved. It is necessary to draw a clear distinction between its glandular structures and adenocarcinoma in situ, involving the preexisting crypts and invasive glands. An attempt was made to assess the possibilities of using as markers of invasion the following stromal proteins and adhesion molecules: CD44, E-cadherin, beta-catenin, tenascin, and laminin. Fifty-three cases of benign glandular changes, 66 cases of dysplasias and adenocarcinomas in situ, and 47 cases of invasive adenocarcinoma were examined. An immunohistochemical study was performed according to the standard protocol using the antibodies to CD44, laminin, tenascin, E-cadherin, and beta-catenin and a semiquantitative assessment of results was made. CD44 was found to be redistributed from the cells to the tumor stroma. CD44 was not detected in the stroma surrounding the intact glands, so were benign epithelial changes. In the tumor environment, there was, on the contrary, a reaction with CD44 in 74.5% of invasive adenocarcinomas cases (p 0.05). CD44 and tenascin are of great diagnostic value in examining invasive and microinvasive adenocarcinomas of the cervix uteri. E-cadherin and beta-catenin are of no diagnostic value in the study groups of pathological processes. Laminin is a potential marker of stromal invasion; however, its expression calls for further investigation.

  11. Genetics and biochemistry of collagen binding-triggered glandular differentiation in a human colon carcinoma cell line

    International Nuclear Information System (INIS)

    Pignatelli, M.; Bodmer, W.F.

    1988-01-01

    The authors have examined the interaction between collagen binding and epithelial differentiation by using a human colon carcinoma cell line (SW1222) that can differentiate structurally when grown in a three-dimensional collagen gel to form glandular structures. As much as 66% inhibition of glandular differentiation can be achieved by addition to the culture of a synthetic peptide containing the Arg-Gly-Asp-Thr (RGDT) sequence, which is a cell recognition site found in collagen. Arg-Gly-Asp-Thr also inhibited the cell attachment to collagen-coated plates. Chromosome 15 was found in all human-mouse hybrid clones that could differentiate in the collagen gel and bind collagen. Both binding to collagen and glandular differentiation of the hybrid cells were also inhibited by Arg-Gly-Asp-Thr as for the parent cell line SW1222. The ability of SW1222 cells to express the differentiated phenotype appears, therefore, to be determined by an Arg-Gly-Asp-directed collagen receptor on the cell surface that is controlled by a gene on chromosome 15

  12. Patient radiation dose during mammography procedures

    International Nuclear Information System (INIS)

    Mohamed, Swsan Awd Elkriem

    2015-11-01

    The objectives of this study were to estimate the patient dose in term of mean glandular dose and assist in optimization of radiation protection in mammographic procedures in Sudan. A total number of 107 patients were included. Four mammographic units were participated. Only one center was using automatic exposure control (AEC). The mean doses in (mGy) for the CC projection were 3.13, 1.24, 2.45 and 0.98 and for the MLO projection was 2.13, 1.26, 1.99 and 1.02 for centers A, B, C, and D, respectively. The total mean dose per breast from both projections was 5.26, 2.50, 4.44 and 1.99 mGy for centers A, B, C and D, respectively. The minimum mean glandular dose was found between the digital system which was operated under AEC and one of the manual selected exposure factors systems, this highlight possible optimization of radiation protection in the other manual selected systems. The kilo volt and the tube current time products should be selected correctly according to the breast thickness in both centers A and C. (author)

  13. Validation of dose-response curve of CRCN-NE - Regional Center for Nuclear Sciences from Northeast Brazil for {sup 60}Co: preliminary results; Validacao da curva dose-resposta do CRCN-NE para {sup 60}Co: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Hwang, Suy F.; Lima, Fabiana F. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Santos, Neide, E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (CCB/UFPE), Recife, PE (Brazil). Departamento de Genetica

    2014-07-01

    The cytogenetic study has the chromosomal alterations as biomarkers in absorbed dose estimation by the body of individuals involved in exposure to ionizing radiation by interpreting a dose response calibration curve. Since the development of the technique to the analysis of data, you can see protocol characteristics, leading the International Atomic Energy Agency indicate that any laboratory with intention to carry out biological dosimetry establish their own calibration curves. The Biological Dosimetry Laboratory of the Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN), Brazil, recently established the calibration curve related to gamma radiation ({sup 60}Co). Thus, this work aimed to start the validation of this calibration curve from samples of three different blood donors which were irradiated with an absorbed known single dose of 1 Gy. Samples were exposed to {sup 60}Co source (Glaucoma 220) located in the Department of Nuclear Energy (DEN/UFPE). After fixation with methanol and acetic acid and 5% Giemsa staining, the frequency of chromosomal alterations (dicentric chromosomes, acentric rings and fragments) were established from reading of 500 metaphases per sample and doses were estimated using Dose Estimate program. The results showed that, using the dose-response curve calibration for dicentrics, the dose absorbed estimated for the three individuals ranged from 0.891 - 1,089Gy, taking into account the range of confidence of 95%. By using the dose-response curve for dicentrics added to rings and for the same interval of confidence the doses ranged from 0,849 - 1,081Gy. Thus, the estimative encompassed known absorbed dose the three individuals in confidence interval of 95%. These preliminary results seems to demonstrate that dicentric dose-response curves and dicentrics plus rings established by CRCN-NE / CNEN are valid for dose estimation in exposed individuals. This validation will continue with samples from different individuals at different doses.

  14. Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment

    NARCIS (Netherlands)

    Bouwman, R. W.; Diaz, O.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Veldkamp, W. J. H.; Dance, D. R.

    2013-01-01

    The recent introduction of digital breast tomosynthesis into clinical practice requires quality control procedures. In this study we have investigated whether the assessment of the average glandular dose for modelled standard breasts can be performed using a combination of polymethyl methacrylate

  15. Estudo comparativo da qualidade de imagem dos modos de aquisição da PET: validação de um protocolo para reduzir a dose de radiação Comparative study on imaging quality in PET acquisition modes: validation of a protocol for reducing the radiation dose

    Directory of Open Access Journals (Sweden)

    Solange Amorim Nogueira

    2009-04-01

    Full Text Available OBJETIVO: O presente experimento visa a validar um protocolo de aquisição em 3D na tomografia por emissão de pósitrons, em substituição ao modo 2D, de forma a reduzir a dose de radiação nos pacientes, sem perda da qualidade de imagens. MATERIAIS E MÉTODOS: Foram realizadas 27 simulações em equipamento Discovery ST, nos modos 2D com quatro minutos de aquisição e 3D com dois e quatro minutos. Utilizou-se um simulador do protocolo da National Electrical Manufacturers Association. No interior deste simulador estão inseridas seis esferas com diferentes diâmetros para a determinação da qualidade de imagem. As aquisições foram comparadas por três médicos nucleares, sem que eles identificassem o modo de aquisição. Cada observador atribuiu o valor igual a 1 quando alguma esfera não foi identificada ou valor 2 para esferas visíveis. RESULTADOS: A análise qualitativa pelo kappa generalizado demonstrou que a frequência de esferas visíveis foi maior no modo 3D com quatro minutos (85% e a porcentagem de concordância também foi maior (88,9%, com kappa generalizado = 0,725 [0,507;0,942]. CONCLUSÃO: O modo 3D com quatro minutos de aquisição e com menores atividades de FDG-18F pode ser utilizado em pacientes com biótipo equivalente ao simulador, sem perda de qualidade de imagem.OBJECTIVE: The present study is aimed at validating a 3D acquisition protocol for positron emission tomography as a replacement for the 2D mode, to reduce the radiation dose delivered to patients, without any loss in the quality of images. MATERIALS AND METHODS: The study comprised 27 simulations in a Discovery ST equipment with four-minute 2D acquisitions, and two-minute and four-minute 3D acquisitions, utilizing a chest phantom according to the National Electrical Manufacturers Association protocol. Six spheres with different diameters were inserted into this phantom as a means for determining the images quality. The images were blindly reviewed by three

  16. Negative ion 'chip-based' nanospray tandem mass spectrometry for the analysis of flavonoids in glandular trichomes of Lychnophora ericoides Mart. (Asteraceae).

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Gates, Paul J; Lopes, Norberto P

    2008-12-01

    This paper reports a method for the analysis of secondary metabolites stored in glandular trichomes, employing negative ion 'chip-based' nanospray tandem mass spectrometry. The analyses of glandular trichomes from Lychnophora ericoides, a plant endemic to the Brazilian 'cerrado' and used in traditional medicine as an anti-inflammatory and analgesic agent, led to the identification of five flavonoids (chrysin, pinocembrin, pinostrobin, pinobanksin and 3-O-acetylpinobanksin) by direct infusion of the extracts of glandular trichomes into the nanospray ionisation source. All the flavonoids have no oxidation at ring B, which resulted in a modification of the fragmentation pathways compared with that of the oxidised 3,4-dihydroflavonoids already described in the literature. The absence of the anti-inflammatory and antioxidant di-C-glucosylflavone vicenin-2, or any other flavonoid glycosides, in the glandular trichomes was also demonstrated. The use of the 'chip-based' nanospray QqTOF apparatus is a new fast and useful tool for the identification of secondary metabolites stored in the glandular trichomes, which can be useful for chemotaxonomic studies based on metabolites from glandular trichomes.

  17. Avaliação da classificação histológica da endometriose observada em implantes de mulheres portadoras de endometriose pélvica superficial e profunda Evaluation of the endometriosis histological classification observed in specimens of women affected by superficial and deeply infiltrating pelvic endometriosis

    Directory of Open Access Journals (Sweden)

    Gil Kamergorodsky

    2007-11-01

    Full Text Available OBJETIVO: avaliar o padrão de diferenciação histológica em lesões de peritônio superficial e lesões de endometriose pélvica profunda (EPP, localizadas em ligamentos úteros-sacros, intestino (reto e sigmóide e septo retovaginal. MÉTODOS: estudo prospectivo não randomizado, que incluiu 139 pacientes. Foram obtidas 234 biópsias (179 com EPP - Grupo Profundas - e 55 com endometriose superficial - Grupo Superficiais. Das 179 lesões de EPP (Grupo Profundas, 15 foram obtidas do septo retovaginal, 72 de nódulos do reto e sigmóide e 92 de ligamentos útero-sacrais. As biópsias foram classificadas em glandulares bem diferenciadas, glandulares indiferenciadas, glandulares mistas e estromal, com base em uma classificação morfológica específica. RESULTADOS: no Grupo Profundas, 33,5% das biópsias apresentaram padrão glandular indiferenciado e 46,9%, padrão glandular misto. No Grupo Superficiais, houve predominância do padrão glandular diferenciado (41,8%. Comparando especificamente as diferentes localizações das biópsias de lesão de EPP (Grupo Profundas, notou-se que o padrão glandular misto foi predominante nos nódulos intestinais (61,1%. CONCLUSÕES: foi possível concluir que há predomínio de endometriose glandular bem diferenciada na endometriose superficial, predomínio da doença mista e indiferenciada na EPP e, especificamente estudando a endometriose de reto e sigmóide, houve predomínio da endometriose glandular mista.PURPOSE: to evaluate the histological differentiation pattern in superficial peritoneum lesions and in deeply infiltrating endometriosis (DIE in utero-sacral ligament, bowel (rectum and sigmoid colon and rectovaginal septum. METHODS: this prospective non-randomized study included 139 patients. Of the total, 234 biopsies were obtained (179 with DIE - Deeply Group - and 55 superficial endometriosis - Superficial Group. From the 179 DIE lesions (Depply Group, 15 were obtained from rectovaginal septum, 72

  18. Oncoplastic Resection of Retroareolar Breast Cancer: Central Quadrantectomy and Reconstruction by Local Skin-Glandular Flap

    International Nuclear Information System (INIS)

    Naguib, S.F.

    2006-01-01

    Background: Patients with central breast neoplasms account for 5 to 20% of breast cancer cases and, for a long time, they have been denied Breast Conservation Surgery (BCS) and conventionally treated with mastectomy. The high incidence of Nipple-Areola-Complex (NAC) involvement usually associated with these tumors necessitates nipple and areolar resection together with an adequate safety margin around the tumor, which yields an unacceptable cosmetic result. With the help of Oncoplastic Surgical Techniques, BCS can be offered to these patients. In this study central quadrantectomy and breast reconstruction by an infero-Iaterally based pedicled flap were evaluated. Patients and Methods: This study comprised 23 women with central breast tumors treated at the National Cancer Institute (NC]), Cairo University and at the Aswan Cancer Center, Egyptian Ministry of Health. Their ages ranged from 31 to 62 years (mean: 48.4±10.2 years). Twenty-two had a palpable mass, while only I had Paget's disease of the nipple without mass. The size of their tumors ranged from 4 to 33mm (mean: 16.9±8.6mm). Only 9 women showed clinical suspicion of NAC involvement in the form of nipple retraction. Seventeen cases had their tumors strictly in the retro-areolar region, while 5 had tumors extending for a maximum of I.5Cm beyond the areolar edge. All patients underwent central quadrantec-tomy with NAC resection removing a cylinder of breast tissue reaching down to the pectoral muscle together with axillary dissection. Advancement of an infero-Iaterally based skin-glandular flap was then carried out. All patients received adjuvant radiotherapy with or without chemotherapy or hormonal therapy. Results: Fourteen patients showed pathological evidence of nipple infiltration (60.8%). The free safety margin (SM) ranged from 9 to 13mm (mean: 10. 0.9mm). This could be accomplished from the first attempt in 18 patients; however, in 5 patients a second wider excision was needed to obtain an adequate

  19. Crescimento e teores de clorofila em mudas de bananeira em função da supressão do pseudocaule, de doses de nitrogênio e de boro Growth and chlorophyll content of banana suckers in function of pseudostem suppression and doses of nitrogen and boron

    Directory of Open Access Journals (Sweden)

    Walter Esfrain Pereira

    2010-12-01

    Full Text Available O objetivo deste experimento foi avaliar a influência da eliminação da gema apical do rizoma e de doses de nitrogênio e boro, sobre a produção e o crescimento de mudas de bananeira. O experimento foi realizado no Centro de Formação de Tecnólogos da UFPB. O delineamento foi em blocos casualizados, com quatro blocos e nove plantas matrizes por parcela, sendo duas plantas úteis. Os fatores avaliados foram doses de N (0 a 240 g/planta e de B (0 a 2,2 g/planta combinados com a matriz experimental Composto Central de Box, originando nove combinações, arranjados fatorialmente com e sem eliminação da gema apical da planta matriz. Os dados foram submetidos à análise de variância e de regressão. A supressão do pseudocaule da planta principal, com a eliminação da gema apical do rizoma aumentou o número de perfilhos, com maior crescimento, exceto do diâmetro do rizoma, o qual diminuiu. Os teores foliares de clorofila total e de B também foram diminuídos, nos perfilhos das bananeiras amputadas. Para a produção de mudas da bananeira ‘Pacovan’, recomenda-se a supressão do pseudocaule da planta principal, com eliminação da gema apical do rizoma e aplicação do N.The objective of this research was to evaluate the influence of the removal in the pseudostem with elimination of the meristem apical of the rhizome and doses of nitrogen and boron, about the production and growth of banana suckers. The experiment was carried out at Centro de Formação de Tecnólogos - UFPB, State of Paraíba. The experimental design was in randomized blocks, with four replications and nine mother plants for experimental unit, being two useful plants. The evaluated valued factors were doses of N (0 to 240 g plant-1 and of B (0 to 240 g plant-1 combined in agreement with the experimental matrix ‘Central Composite’, originating nine combinations, which were arranged factorially with suppression and without suppression of the pseudostem of the mother

  20. Caracterização da dose letal mínima por irradiação gama para Penicillium citrinum Characterization of minimum lethal dosis of gama irradiation to Penicillium citrinum

    Directory of Open Access Journals (Sweden)

    A. N. Norberg

    1993-12-01

    Full Text Available O uso das radiações ionizantes na destruição de microrganismos responsáveis pela deterioração de alimentos ou causadores de infecções ou toxinfecções alimentares, constituiu-se aplicação da energia nuclear, para fins verdadeiramente pacíficos. Penicillium citrinum é um fungo produtor de micotoxinas, responsáveis por intoxicações em humanos e animais que se utilizam de alimentos contaminados. Há escassez de informações sobre a resistência do P. citrinum à irradiação gama; assim esta pesquisa objetivou determinar a dose letal por irradiação gama para esse microrganismo. Foram irradiadas 76 suspensões, contendo aproximadamente 100.000 esporos por mililitro, com doses entre 0,2 e 2,2 KGy (KiloGray, sendo os sobreviventes re-irradiados com doses até 3,0 KGy. O fungo foi totalmente destruído com dose de 2,2 KGy. P. citrinum descendentes dos sobreviventes de 2,0 KGy, quando re-irradiados também foram totalmente destruídos com dose de 2,2 KGy. Observou-se um aumento da resistência às doses mais baixas em relação ao fungo não irradiadoThe use of nuclear power through radiation for the destruction of microrganisms which cause food decay, and toxicosis, is specifically for peaceful purposes. Penicillium citrinum is a fungus which produce mycotoxins responsible for intoxication in humans and animals as a result of eating contaminated food. There is little informations on the resistance of P. citrinum to radiation. The objective of this research is to determine the lethal dose of gama radiation for these microrganisms. Seventy six suspensions containing approximately 100,000 spores/ml received a dose of radiation between 0.2 and 2.2 KGy (KiloGray, being one sample still alive re-irradiated with doses up to 3.0 KGy. The fungus were totally destroyed with a 2.2 KGy. Seventy six suspensions containing approximately 100,000 spores/ml received a dose of radiation between 0.2 and 2.2 KGy, being one sample still alive re

  1. Radiochromic film use to record dose profile variations in chest CT scan; Utilizacao do filme radiocromico para registro da variacao do perfil de dose em varredura de TC de torax

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P.; Santana, Priscila C., E-mail: aprata@des.cefetmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Silva, Teogenes A. da; Alonso, Thessa C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-12-15

    The CT scans generate higher doses in patients than those caused by other types of diagnostic radiology using the attenuation of X-ray beams. Technological advances have increased the clinical applications of computed tomography (CT) and consequently the demand for these exams. Dose reduction strategies are difficult to implement because of a lack of proper guidance on the CT scanning. However, CT offers the possibility of adjusting the image acquisition parameters according to the patient physical profile and the diagnostic application for which it is intended to scan. Knowledge of the dose distribution is important when thinking about varying the acquisition parameters to reduce the dose. In this work was used a PMMA chest phantom to observe the dose deposition in 5 areas. Radiochromic film strips were placed inside the chest phantom, in peripheral and in the central region. The phantom was placed in the scanner isocenter and it was performed the irradiation of its central region using a chest acquisition protocol. After the phantom CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were reworked to obtain the dose variation profiles for each position. The results showed a wide variation in absorbed dose by the phantom, either within a same position along the length of the film strip, as in the comparison among the five regions which the strips are placed. In this second case the dose variations were even greater. (author)

  2. Evaluation of the image quality criteria and study of doses in a mammography department

    International Nuclear Information System (INIS)

    Alcantara, Marcela Costa

    2009-01-01

    The mammographic image quality criteria published by European Commission were implemented in three mammography equipment of a same radiology department in a hospital of Sao Paulo city. Among the mammography equipment, two use the screen-film system and one of them uses the indirect digital system. During the data collection, it was noted the need to conduct a study about image rejection in each mammography equipment. Therefore, this study was realized and, after that, the results in each mammography equipment of image rejection and image percentage that present each quality criterion it were compared. At the same time of this studies, it was realized other study about surface entrance dose and average glandular dose. These doses it was estimated based on different methods published by different groups of researcher, for all combinations anode filter available in the equipment. To estimate the surface entrance dose following the methodology published in Avenue's' guide and the average glandular dose following the Wu' methodology, it was developed a phantom, in different thicknesses of acrylic, to simulate a breast. Finally, the image quality it was associated with the dose received by patient. The digital equipment shows better results in the evaluation of quality criteria, lower rate of image rejection and lower values of average glandular dose and surface entrance dose in all methods studied. But it is not sufficient, because is not adequate for patients with great breast. (author)

  3. Influência da irrigação, da densidade de plantio e da adubação nitrogenada nas características morfogênicas, estruturais e de produção do capim-tanzânia Morphogenesis and structural characteristics and production of guinea grass irrigated under different plants density and nitrogen doses

    Directory of Open Access Journals (Sweden)

    Marcela de Azevedo Magalhães

    2011-11-01

    Full Text Available O experimento foi conduzido com os objetivos de avaliar a altura do dossel com 95% de interceptação luminosa e quantificar a influência da adubação nitrogenada e da densidade de plantas nas características morfogênicas e estruturais de capim-tanzânia. Quatro doses de nitrogênio, N (0, 80, 160 e 320 kg.ha-1, foram combinadas com três densidades de plantas (9, 25 e 49 plantas.m-2, em um arranjo fatorial 4 × 3, em delineamento inteiramente casualizado com três repetições, para avaliação da produção de biomassa, e duas repetições, para avaliação das características morfogênicas e estruturais. O acúmulo de MS total durante o período experimental foi influenciado pela adubação nitrogenada e pela densidade de plantas. No período das águas, as maiores doses de nitrogênio diminuíram o intervalo de colheitas e, consequentemente, aumentaram o número de colheitas. A altura do dossel de capim-tanzânia com 95% de IL foi positivamente influenciada pela densidade de plantas nos períodos das águas e de transição água-seca e seca. A altura do capim-tanzânia com 95% de IL apresentou variações ao longo das avaliações, de modo que os valores foram maiores (próximos a 70 cm no período das águas, seguido pelos períodos de transição água-seca e seca.This experiment was carried out to evaluate canopy height of guinea grass with 95% of photosynthetic active radiation interception and quantify the nitrogen fertilization influence and plants' density on the morphogenesis and structural characteristics of Tanzania grass. Four doses of N (0, 80, 160 e 320 kg.ha-1, were arranged with three plant densities (9, 25 and 49 plants.m-2, according to 4 × 3 completely randomized design, with three repetitions. Total dry matter (DM accumulation throughout the experimental period was influenced by nitrogen fertilization and plants' density. In the rainy period, the higher nitrogen fertilization decreased the harvesting intervals, and

  4. Assessment of influence of OSL dosimeters in the skin dose in radiotherapy: study for Monte Carlo simulation; Avaliacao da influencia de dosimetros OSL na dose na pele em radioterapia: estudo por simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Schuch, Franciely F.; Nicolucci, Patricia, E-mail: franschuch@yahoo.com.br [Universidade de Sao Paulo (USP), Ribeiraoo Preto, SP (Brazil)

    2017-11-01

    The interest in optically stimulated luminescence (OSL) dosimetry materials is growing due to its potential use in quality control in Radiotherapy. The use of these dosimeters for in vivo dosimetry, however, may influence the dose to the skin and deeper tissues in the patient. The goal of this study is to evaluate the influence of the OSL Al{sub 2}O{sub 3} material in dose deposited in the skin and deep in Radiotherapy. Monte Carlo simulation is used to evaluate this purpose when OSL dosimeters of Al{sub 2}O{sub 3} are positioned on the skin surface of the patient. Percentage depth dose curves for clinical beams of 6 and 10 MV were simulated with and without the presence of the dosimeter on the surface of a water phantom. The results showed a decrease of doses in regions close to the surface of the skin. In the build-up region, the maximum decreases of dose produced by the presence of the dosimeters were 52,5% and 47,5% for the 6 and 10 MV beams, respectively. After the build-up region, there are not significant changes in the doses for any of the used beams. The differences of doses found are due to the influence of the dosimetric material on the relative fluence of electrons near the end surface of the dosimeter. Thus, the results showed that the presence of the dosimetric material on the surface interferes on the skin dose. However, these dosimeters do not cause dose variations in depths of clinical interest, allowing its application in routine in vivo dosimetry in Radiotherapy. (author)

  5. Radiation dose evaluation in pediatric urethrocystography professionals, patients and companions of patients; Avaliação da dose em profissionais, pacientes e acompanhantes de pacientes em exames de uretrocistografia pediátrica

    Energy Technology Data Exchange (ETDEWEB)

    Just, W.; Lykawka, R.; Anés, M.; Cunha, R.; Goulart, J.M.; Bacelar, A., E-mail: rlykawka@hcpa.edu.br [Hospital de Clínicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil). Laboratório de Imagens Médicas e Radioproteção

    2017-07-01

    Urinary urethrocystography is suggested as the second stage in the diagnosis of urinary tract infection, according to the ACR Adequacy Criteria. When performed in pediatric patients, it may be necessary to contain the patient, increasing the risk of exposure of the professionals involved. To assess the exposure levels of those involved in this test, we estimated the radiation doses in patients, companions and professionals. A total of 56 pediatric urethrocystography examinations were performed on the SHIMADZU Sonialvision fluoroscopy equipment. We measured the DAP with the VacuDAP Duo equipment. The effective dose of radiologist and companion were estimated using RaySafe i2 dosimeters; the equivalent dose received on the radiologist's pulse was estimated with optically stimulated dosimeters. The results of the collected data are expressed by median [first quartile - third quartile]. The exposure time was 5.38 [3.00 - 9.64] s; or DAP 119.58 [76.62 - 350.88] μGym²; the dose for the radiologist physician in the thorax 0.01 [0.00 - 0.02] mSv and in the pulse 0.05 [0.03 - 0.14] mSv; the companion dose 0.00 [0.00 - 0.01] mSv. Despite the radiologist's proximity to the primary X-ray beam, his dose to the wrist and chest does not reach the limit of annual doses established in Brazilian legislation. The dose of the companion is less than the effective dose condition established in national legislation.

  6. Optimization of the dose versus noise in the image on protocols for computed tomography of pediatric head;Otimizacao da relacao dose versus ruido na imagem em protocolos de tomografia computadorizada de cranio pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Saint' Yves, T.L.A.; Travassos, P.C.; Goncalves, E.A.S.; Mecca, F.A.; Silveira, T.B. [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This article aims to establish protocols optimized for computed tomography of pediatric skull, to the Picker Q 2000 tomography of the Instituto Nacional de Cancer, through the analysis of dose x noise on the image with the variation of values of m As and k Vp. We used a water phantom to measure the noise, a pencil type ionization chamber to measure the dose in the air and the Alderson Randon phantom for check the quality of the image. We found values of m As and k Vp that reduce the skin dose of the original protocol used in 35.9%, maintaining the same image quality at a safe diagnosis. (author)

  7. Acúmulo e repartição da matéria seca da planta de pepino tipo conserva sob três doses de nutrientes minerais Dry matter accumulation and distribution of pickling cucumber plants under three mineral nutrient levels

    Directory of Open Access Journals (Sweden)

    Hugo Nicasio Rodríguez Espínola

    2001-06-01

    Full Text Available Determinou-se o efeito de três doses de nutrientes minerais sobre o acúmulo e distribuição da matéria seca da planta de pepino tipo conserva, híbrido Crispina. As plantas foram cultivadas em sacolas plásticas com 4,6kg de substrato composto por uma mistura de 40% de casca de arroz e 60% de solo, no interior de uma estufa de polietileno, na primavera de 1998 e no verão de 1999. Foi empregado um delineamento experimental de blocos casualizados, com três repetições e 15 plantas por parcela. Os tratamentos foram constituídos por três níveis múltiplos de uma dose padrão de nutrientes aplicada para cada planta, contendo N-P-K-Ca e Mg nas quantidades de 0,8-0,12-0,8-0,46-0,086g.pl-1, com 0,33m de solução de micronutrientes e 0,07m de quelato de ferro. Os níveis corresponderam às quantidades de 50%, 100% e 150% da dose padrão, denominados de tratamentos T1, T2 e T3, respectivamente, aplicados semanalmente através da fertirrigação em todas as plantas de uma mesma parcela. Determinou-se a matéria seca dos diferentes órgãos da parte aérea da planta a intervalos semanais. Houve efeito significativo dos tratamentos no acúmulo da matéria seca, nos dois experimentos. A maior fração foi alocada para os frutos, atingindo o valor mais elevado de 0,64 na primavera. Concluiu-se que a distribuição da matéria seca desse material vegetal não é constante, sofrendo interações com as variáveis do ambiente.It was determined the effect of three mineral nutrient levels on dry matter accumulation and distribution of pickling cucumber plants, hybrid Crispina, grown inside a polyethylene greenhouse, in spring 1998 and in summer 1999. Planting was made in bags filled with 4.6kg of a substrate mixture composed by 40% rice husks and 60% soil. A randomized block experimental design was used, with three replications and15 plants per plot. A reference nutrient dose was supplied weekly to each one of the plants, with the following composition

  8. Incidência e severidade do "furo de bala" em folhas da ameixeira sob doses de nitrogênio e potássio Incidence and severity of 'shot hole' in plum´s leaves related into nitrogen and potassium doses

    Directory of Open Access Journals (Sweden)

    Inês Tutida

    2007-10-01

    Full Text Available A produção integrada (PI vem suprir uma demanda crescente de frutos de qualidade, garantir segurança alimentar, produção com qualidade ambiental e rastreabilidade. Na visão da PI, as práticas da adubação e do controle de doenças estão intimamente relacionadas; no entanto, tem sido negligenciadas e pouco estudadas, principalmente para a doença "furo de bala" (Wilsonomyces carpophilus em folhas de ameixeira (Prunus salicina. O objetivo deste trabalho foi avaliar a incidência e severidade dessa doença em doses combinadas de adubação com N e K em dois ciclos de cultivo comercial de ameixeira cv "Reubennel", no município de Araucária (PR. Foram utilizadas cinco doses de N (40, 80, 120, 160 e 200kg ha-1ano-1 e duas de K (55 e 110kg ha-1ano-1. Realizaram-se sete avaliações para incidência e severidade a cada 20 dias, no período de novembro/2004 a março/2005 e em data única em outubro/2005. Os dados da primeira safra foram integralizados no tempo, constituindo a área abaixo da curva de progresso da doença (AACPD da incidência e severidade, e os dados foram analisados estatisticamente pela teoria dos modelos lineares generalizados para dados longitudinais. A doença foi mais severa no segundo ano de avaliação, sendo observado o máximo de 0,70 e 2,25 para o primeiro e o segundo ano, respectivamente. A incidência e a severidade de "furo de bala" em folhas de ameixeira são superiores nas doses de 160 e 200kg ha-1ano-1 de nitrogênio. O potássio não interfere na incidência e severidade da doença devido ao seu elevado teor encontrado no solo e na planta.Integrated Production (IP can provide the growing demand for quality fruit, food safety, environmental protection, and product traceability. In IP, fertilization practices and disease control are viewed as being closely related. However, this linkage has been mostly ignored and few studies are available concerning the 'shot hole' phytopathogen (Wilsonomyces carpophilus in

  9. Produção e composição químico-bromatológica da aveia preta fertilizada com doses crescentes de dejeto líquido suíno Production and chemical composition of the common black oats fertilized with growing doses of liquid swine manure

    Directory of Open Access Journals (Sweden)

    Daniela Mondardo

    2011-06-01

    Full Text Available O trabalho teve como objetivo avaliar o efeito da aplicação de doses crescentes de dejeto líquido suíno sobre a produção e composição químico-bromatológica da parte aérea da aveia preta. O experimento foi conduzido em sistema de plantio direto sob o delineamento em blocos casualizados com quatro repetições e os tratamentos constituídos pela aplicação de 0; 10; 20; 30; 40 e 50 m³ ha-1 de dejeto líquido suíno. Foram determinados a produção de MS da parte aérea, a relação folha:colmo e os teores de proteína bruta (PB, fibra em detergente ácido (FDA, fibra em detergente neutro (FDN, matéria mineral (MM, matéria orgânica (MO, nitrogênio (N, fósforo (P, potássio (K, cálcio (Ca, magnésio (Mg, cobre (Cu, zinco (Zn, manganês (Mn e ferro (Fe. A aplicação de dejeto líquido suíno não promoveu efeitos significativos sobre a produção de MS e teores de FDN, MM e MO, mas promoveu aumento linear da relação folha:colmo e do teor de PB e redução linear no teor de FDA. Quanto aos minerais, as doses de dejeto líquido suíno promoveram aumento linear nos teores de N, P, K, Ca e Zn, sem efeitos sobre os demais minerais estudados. A utilização de dejeto líquido suíno na fertilização da cultura da aveia até a dose de 50 m³ ha-1 não aumenta a produção de forragem mas eleva o valor nutricional.The work has as objective evaluate the effect of application of increasing doses of pig slurry under yield and chemical composition of black oat shoot. The experiment was carried out in no-tillage system under experimental design of randomized blocks with four replications and the treatments composed by application of 0; 10; 20; 30; 40; 50 m³ ha-1 of pig slurry. Were determined the yield of total dry mass, the leaf-stem ratio and content of crude protein (CP, acid detergent fiber (ADF, neutral detergent fiber (NDF, mineral matter (MM, organic matter (OM, nitrogen (N, phosphorus (P, potassium (K, calcium (Ca, magnesium (Mg

  10. Optimization in the nuclear fuel cycle I: Temporal variation of dose rate; Optimização no ciclo do combustível nuclear I: variação temporal da taxa de dose

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S., E-mail: pereiras@gmail.com [Universidade Veiga de Ameida (UVA), Rio de Janeiro, RJ (Brazil); Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Fernandes, T.S.; Mello, C.R., E-mail: lararapls@hotmail.com, E-mail: Ademir@nuclear.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Kelecom, A. [Universidade Federal Fluminense (UFF), Niterói, RJ (Brazil)

    2017-07-01

    Radioprotection aims to protect man and the environment from the harmful effects of radiation. Radioprotection is based on three fundamental principles: justification, dose limitation and optimization. Optimization is a complementary principle to dose limitation and should be applied in all phases of development, and even in unregulated situations. The aim of this work is to use the exposure rate as a tool to optimize radioprotection. The exposure rate at a nuclear facility was monitored at 15 points for one year and statistical tools for data analysis were proposed as auxiliary tools for the process of optimizing the dose rates measured at the facility. A total of 9,125 exposure-rate measures were performed during 2014. The monthly averages were organized by sampling point and by month of the year. No statistical difference was observed in the monthly variation of the dose rate. Therefore, this variable can not be used in the optimization process in this nuclear installation.

  11. Dose rate range extension of the calibration of dosemeters at LNMRI, Rio de Janeiro, Brazil; Expansao da faixa de taxas de dose para a calibracao de instrumentos de medir radiacao no LNMRI, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, T.S.; Carlos, M.T.; Ramos, M.M.O., E-mail: tschirn@ird.gov.b, E-mail: marcia@ird.gov.b, E-mail: mmoramos@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The present work has an objective the implantation of a experimental arrange for application of essays of instrument calibration for measurement of low dose rate, which measure rate less than 10 {mu}Sv/h

  12. Analysis of dose in heterogeneity adjuvant radiotherapy after surgical treatment of cases of breast cancer; Analise da heterogeneidade de dose em radioterapia adjuvante apos tratamento cirurgico de casos de cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Grechi, Bruna E.; Schwarz, Ana Paula, E-mail: anapaulaschwarz@yahoo.com.br [Centro Universitario Franciscano (UNIFRA), Santa Maria, RS (Brazil); Teston, Adriano; Rodrigues, Joanilso S. [Clinica de Radioterapia Santa Maria, Santa Maria, RS (Brazil)

    2013-12-15

    Assuming the systems planning radiotherapy recognize all body structures of the same density (d=1 g/cm³), variations in electron density within the irradiated area, as is the case of patients who undergo reconstruction mammary processes and use tissue expanders, may influence the dose distribution in the treatment and may produce heterogeneities which are not measured by changing its actual distribution into healthy tissues or in the target volume to be irradiated. Through the calculation of the algorithms' dose distribution of the XiO® planning system (Fast Fourier Transform, Convolution, Superposition, Fast Superposition e Clarkson), when using correction of heterogeneity between tissues of different densities, there was obtained a percentage ratio of dose increase in the structures of interest, and of the amount of absorbed dose by healthy organs adjacent to the target volume. (author)

  13. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE; Um sistema dosimetrico de referencia para o intervalo de doses da radioterapia baseado na alanina/RPE

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rodrijr@net.ipen.br

    2001-07-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10{sup 5} Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  14. Evaluation of radioiodine therapy with fixed doses of 10 and 15 mCi in patients with Graves disease; Avaliacao da radioiodoterapia com doses fixas de 10 e 15 mCi em pacientes com doenca de Graves

    Energy Technology Data Exchange (ETDEWEB)

    Canadas, Viviane; Vilar, Lucio; Moura, Eliane; Brito, Ana; Castellar, Enio [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Hospital das Clinicas. Servico de Endocrinologia]. E-mail: vivi2207@ig.com.br

    2007-10-15

    The treatment options for the hyperthyroidism of Graves' disease are antithyroid drugs, surgery and radioiodine, none of which is considered ideal, as they do not act directly on the etiopathogenesis of the disease. Radioiodine has been increasingly used as the treatment of choice because it is a safe and definitive therapy whose administration is very easy. Some authors prefer to administer higher doses in order to deliberately induce hypothyroidism, while others recommend lower doses that result in a lower incidence of hypothyroidism and a greater incidence of euthyroidism. There is no consensus for the optimal regimen of fixed doses to be used and this is the main focus of the present study, where doses of 10 and 15 mCi of {sup 131}I were compared. Among the 164 patients analyzed, 61 (37.2%) were submitted to 10 mCi and 103 (62.8%) to 15 mCi. In the longitudinal analysis it was observed that remission of the hyperthyroidism was statistically different in the sixth month (p < 0.001), being higher in the group that used the dose of 15 mCi, but similar in both groups at 12 and 24 months. It may be concluded that the administration of fixed doses of 10 and 15 mCi of {sup 131}I brought about a similar remission of the hyperthyroidism after 12 months of treatment. Moreover, the remission rate of the hyperthyroidism had no association with age, sex or previous therapy with antithyroid drugs. (author)

  15. Effect of 935-MHz phone-simulating electromagnetic radiation on endometrial glandular cells during mouse embryo implantation.

    Science.gov (United States)

    Liu, Wenhui; Zheng, Xinmin; Qu, Zaiqing; Zhang, Ming; Zhou, Chun; Ma, Ling; Zhang, Yuanzhen

    2012-10-01

    This study examined the impact of 935MHz phone-simulating electromagnetic radiation on embryo implantation of pregnant mice. Each 7-week-old Kunming (KM) female white mouse was set up with a KM male mouse in a single cage for mating overnight after induction of ovulation. In the first three days of pregnancy, the pregnant mice was exposed to electromagnetic radiation at low-intensity (150 μW/cm(2), ranging from 130 to 200 μW/cm(2), for 2- or 4-h exposure every day), mid-intensity (570 μW/cm(2), ranging from 400 to 700 μW/cm(2), for 2- or 4-h exposure every day) or high-intensity (1400 μW/cm(2), ranging from 1200 to 1500 μW/cm(2), for 2- or 4-h exposure every day), respectively. On the day 4 after gestation (known as the window of murine embryo implantation), the endometrium was collected and the suspension of endometrial glandular cells was made. Laser scanning microscopy was employed to detect the mitochondrial membrane potential and intracellular calcium ion concentration. In high-intensity, 2- and 4-h groups, mitochondrial membrane potential of endometrial glandular cells was significantly lower than that in the normal control group (Pelectromagnetic radiation and longer length of the radiation are required to inflict a remarkable functional and structural damage to mitochondrial membrane. Our data demonstrated that electromagnetic radiation with a 935-MHz phone for 4 h conspicuously decreased mitochondrial membrane potential and lowered the calcium ion concentration of endometrial glandular cells. It is suggested that high-intensity electromagnetic radiation is very likely to induce the death of embryonic cells and decrease the chance of their implantation, thereby posing a high risk to pregnancy.

  16. Biological effects in lymphocytes irradiated with {sup 99m}Tc: determination of the curve dose-response; Efeitos biologicos em linfocitos irradiados com {sup 99m}Tc: determinacao da curva dose-resposta

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Romero Marcilio Barros Matias de

    2002-08-01

    Biological dosimetry estimates the absorbed dose taking into account changes in biological parameters. The most used biological indicator of an exposition to ionizing radiation is the quantification of chromosomal aberrations of lymphocytes from irradiated individuals. The curves of dose versus induced biological effects, obtained through bionalyses, are used in used in retrospective evaluations of the dose, mainly in the case of accidents. In this research, a simple model for electrons and photons transports was idealized to simulate the irradiation of lymphocytes with {sup 99m} Tc, representing a system used for irradiation of blood cells. The objective of the work was to establish a curve of dose versus frequencies of chromosomal aberrations in lymphocytes of human blood. For the irradiation of blood samples micro spheres of human serum of albumin (HSAM) market with {sup 99m} Tc were used, allowing the irradiation of blood with different administered activities of {sup 99m} Tc, making possible the study the cytogenetical effects as a function of such activities. The conditions of irradiation in vivo using HSAM spheres marked with {sup 99m} Tc were simulated with MCNP 4C (Monte Carlo N-Particle) code to obtain the dose-response curve. Soft tissue composition was employed to simulate blood tissue and the analyses of the curve of dose versus biological effect showed a linear quadratic response of the unstable chromosomal aberrations. As a result, the response of dose versus chromosomal aberrations of blood irradiation with {sup 99m} Tc was best fitted by the curve Y=(8,99 {+-}2,06) x 1-{sup -4} + (1,24 {+-}0,62) x 10{sup -2} D + (5,67 {+-} 0,64) x 10{sup -2} D{sup 2}. (author)

  17. The key role of peltate glandular trichomes in symbiota comprising clavicipitaceous fungi of the genus periglandula and their host plants.

    Science.gov (United States)

    Steiner, Ulrike; Kucht, Sabine Hellwig neé; Ahimsa-Müller, Mahalia A; Grundmann, Nicola; Li, Shu-Ming; Drewke, Christel; Leistner, Eckhard

    2015-04-16

    Clavicipitaceous fungi producing ergot alkaloids were recently discovered to be epibiotically associated with peltate glandular trichomes of Ipomoea asarifolia and Turbina corymbosa, dicotyledonous plants of the family Convolvulaceae. Mediators of the close association between fungi and trichomes may be sesquiterpenes, main components in the volatile oil of different convolvulaceous plants. Molecular biological studies and microscopic investigations led to the observation that the trichomes do not only secrete sesquiterpenes and palmitic acid but also seem to absorb ergot alkaloids from the epibiotic fungal species of the genus Periglandula. Thus, the trichomes are likely to have a dual and key function in a metabolic dialogue between fungus and host plant.

  18. Study of distribution dose for chest radiography using the computational model ALDERSON/EGSnrc; Estudo da distribuição de dose para radiografia de tórax utilizando o modelo computacional ALDERSON/EGSnrc

    Energy Technology Data Exchange (ETDEWEB)

    Muniz, B.C., E-mail: bianca.cm95@gmail.com [Instituto de Educação, Ciência e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil). Lab. de Dosimetria Numérica; Menezes, C.J.M. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil). Lab. de Física Médica

    2017-07-01

    Numerical dosimetry uses Computational Exposure Models (MCE) to perform dose studies in situations of radiation exposure without the need for individuals to be exposed. MCEs are essentially composed of a simulator of the radioactive source, a Monte Carlo code, and a phantom of voxels representing the human anatomy. The objective of this work was to perform a study of the dose distribution in the thoracic region in radiographic exams using the MCE ALDERSON / EGSnrc. For that, virtual simulations were performed using Monte Carlo Method techniques to calculate the dose in the simulator of voxels representative of the thoracic region. The results show that most beam energy was deposited in the skeleton for all simulated radiological techniques, while smaller fractions were deposited in the lungs and soft tissue. For example, at 90 kV voltage, 14% of the energy was deposited in the bone medium, while lungs and soft tissue receive only 5 and 3%, respectively. It is concluded that the ALDERSON / EGSnrc MCE can be used for studies of the dose distribution on chest radiographs used in radiodiagnosis practice, thus optimizing dose absorbed in the patient in clinical exams.

  19. Evaluation of occupational radiation dose in nuclear medicine: radiopharmaceutical administration to scintiscanning exams of myocardial perfusion; Avaliacao da dose de radiacao ocupacional em medicina nuclear: administracao de radiofarmacos em exames de cintilografria de perfusao miocardica

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, Cassio V., E-mail: cassiok@yahoo.com [Medicina Nuclear do Triangulo (MNT), Uberlandia, MG (Brazil); Michelin, Charlie A.; Jakubiak, Rosangela R., E-mail: charlie@utfpr.edu.br, E-mail: requi@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Lemes, Alyne O.; Silva, Juliana L.M., E-mail: alyne275@gmail.com, E-mail: jujumontesdocinho@gmail.com [Faculdade do Trabalho (FATRA), Uberlandia, MG (Brazil)

    2013-11-01

    In nuclear medicine, workers directly involved in exams are constantly exposed to ionizing radiation. The procedure for administration of the radiopharmaceutical to the patient is one of the most critical times of exposure. In tests of myocardial perfusion scintigraphy (MPS) administration of radiopharmaceutical repeats the steps of rest and cardiac stress. In this study, we used a Geiger -Mueller detector for measuring occupational radiation doses for during the administration of technetium- {sup 99m}- sestamibi in MPS tests. In the evaluation, discriminated the stages of examination and related professional experience time to doses measures at home. It were followed 110 procedures at home (55 conducted by professionals with over 5 years experience and 55 conducted by professionals with less than 1 year of experience) and 55 effort procedures. The results showed that the rest of the procedure time and dose are related to the experience of the worker. More experienced workers were faster (mean: 43 {+-} 16 vs 67 {+-} 25 seconds / procedure), and therefore received lower doses (mean 0.57 {+-} 0.16 versus 0.80 {+-} 0.24 {mu}Sv / procedure), both with statistical significance (p <0.001). In step effort, there were procedures lasting longer (mean: 19 {+-} 2 minutes / procedure), which resulted in higher doses (mean 3.0 {+-} 0.6 {mu}Sv / procedure)

  20. Quantification of micronuclei in blood lymphocytes of patients exposed to gamma radiation for dose absorbed assessment; Quantificacao de micronucleos em linfocitos de pacientes expostas a radiacao gama para a avaliacao da dose absorvida

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Isvania Maria Serafim da Silva

    2003-02-15

    Dose assessment in an important step to evaluate biological effects as a result of individual exposure to ionizing radiation. The use of cytogenetic dosimetry based on the quantification of micronuclei in lymphocytes is very important to complement physical dosimetry, since the measurement of absorbed dose cannot be always performed. In this research, the quantification of micronuclei was carried out in order to evaluate absorbed dose as a result of radiotherapy with {sup 60}Co, using peripheral blood samples from 5 patients with cervical uterine cancer. For this purpose, an aliquot of whole blood from the individual patients was added in culture medium RPMI 1640 supplemented with fetal calf serum and phytohaemagglutinin. The culture was incubated for 44 hours. Henceforth, cytochalasin B was added to block the dividing lymphocytes in cytokinesis. The culture was returned to the incubator for further of 28 hours. Thus, cells were harvested, processed and analyzed. Values obtained considering micronuclei frequency after pelvis irradiation with absorption of 0,08 Gy and 1,8 Gy were, respectively, 0,0021 and 0,052. These results are in agreement with some recent researches that provided some standard values related to micronuclei frequency induced by gamma radiation exposure in different exposed areas for the human body. The results presented in this report emphasizes biological dosimetry as an important tool for dose assessment of either total or partial-body exposure to ionizing radiation, mainly in retrospective dose investigation. (author)

  1. Optimization on the dose versus noise in the image on protocols for computed tomography of pediatric head; Otimizacao da relacao dose versus ruido na imagem em protocolos de tomografia computadorizada de cranio pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Saint' Yves, Thalis L.A.; Travassos, Paulo Cesar B.; Goncalves, Elicardo A.S.; Mecca A, Fernando; Silveira, Thiago B. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)], e-mail: fmecca@inca.gov.br, e-mail: thalis09@yahoo.com.br

    2010-03-15

    This article aims to establish protocols optimized for computed tomography of pediatric skull, to the Picker Q2000 tomography of the Instituto Nacional de Cancer, through the analysis of dose x noise on the image with the variation of values of mAs and kVp. We used a water phantom to measure the noise, a pencil type ionization chamber to measure the dose in the air and the Alderson Randon phantom for check the quality of the image. We found values of mAs and kVp that reduce the skin dose of the original protocol used in 35.9%, maintaining the same image quality at a safe diagnosis. (author)

  2. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources; Aplicabilidade de um prototipo para determinacao da dose absorvida utilizando equipamentos de braquiterapia com fontes de IR-192

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila, E-mail: vlsouza@cnen.gov.br, E-mail: mayaradqf@hotmail.com, E-mail: rodriguesss@hootmail.com, E-mail: waldecy@cnen.gov.br, E-mail: riziakeila@hotmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.

  3. Comparison of absorbed dose in the cervix carcinoma therapy by brachytherapy of high dose rate using the conventional planning and Monte Carlo simulation; Comparacao da dose absorvida no tratamento do cancer ginecologico por braquiterapia de alta taxa de dose utilizando o planejamento convencional do tratamento e simulacao de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aneli Oliveira da

    2010-07-01

    This study aims to compare the doses received for patients submitted to brachytherapy High Dose Rate (HDR) brachytherapy, a method of treatment of the cervix carcinoma, performed in the planning system PLATO BPS with the doses obtained by Monte Carlo simulation using the radiation transport code MCNP 5 and one female anthropomorphic phantom based on voxel, the FAX. The implementation of HDR brachytherapy treatment for the cervix carcinoma consists of the insertion of an intrauterine probe and an intravaginal probe (ring or ovoid) and then two radiographs are obtained, anteroposterior (AP) and lateral (LAT) to confirm the position of the applicators in the patient and to allow the treatment planning and the determination of the absorbed dose at points of interest: rectum, bladder, sigmoid and point A, which corresponds anatomically to the crossings of the uterine arteries with ureters The absorbed doses obtained with the code MCNP 5, with the exception of the absorbed dose in the rectum and sigmoid for the simulation considering a point source of {sup 192}Ir, are lower than the absorbed doses from PLATO BPS calculations because the MCNP 5 considers the chemical compositions and densities of FAX body, not considering the medium as water. When considering the Monte Carlo simulation for a source with dimensions equal to that used in the brachytherapy irradiator used in this study, the values of calculated absorbed dose to the bladder, to the rectum, to the right point A and to the left point A were respectively lower than those determined by the treatment planning system in 33.29, 5.01, 22.93 and 19.04%. These values are almost all larger than the maximum acceptable deviation between patient planned and administered doses (5 %). With regard to the rectum and bladder, which are organs that must be protected, the present results are in favor of the radiological protection of patients. The point A, that is on the isodose of 100%, used to tumor treatment, the results

  4. Disponibilidade de nitrato em solos brasileiros sob efeito da calagem e de fontes e doses de nitrogênio Nitrate availability in Brazilian soils under effect of liming and sources and amounts of nitrogen

    Directory of Open Access Journals (Sweden)

    CARLOS ALBERTO SILVA

    2000-12-01

    Full Text Available Este trabalho objetivou avaliar os efeitos da calagem e de fontes e doses de N sobre a disponibilidade de nitrato, em amostras (020 cm de solos brasileiros. Foram conduzidos dois experimentos: um com cinco solos da Bahia e o outro com cinco solos de Minas Gerais. Os materiais de solo foram previamente umedecidos e incubados por sete dias, a 26°C, visando ativar a flora microbiana. Nas amostras de solo da Bahia, aplicou-se a uréia ou o sulfato de amônio nas concentrações de 50, 100, 150 e 200 mg de N por kg de solo e nas de Minas Gerais, foi avaliado o efeito da calagem sobre a nitrificação. Os materiais de solo foram incubados a 26°C por 15 dias. Independentemente da dose de N aplicada, auréia nitrificou mais rapidamente do que o sulfato de amônio. Na Areia Quartzosa não foi observada nitrificação líquida do Nsulfato de amônio, sendo constatada, porém, a oxidação do Nuréia. A calagem afetou a nitrificação, notando-se nos solos que receberam calcário maior disponibilidade de nitrato. A saturação por bases e o teor de matéria orgânica apresentaram, respectivamente, a melhor correlação com o nitrato formado e os teores de uréia presentes no solo ao término da incubação.The aim of this work was to evaluate the effect of liming and sources and doses of nitrogen on nitrate availability in Brazilian soils. Two experiments were carried out: one with five soils from Bahia State and the other with five soils from Minas Gerais State. Soil samples were previously moistened and incubated at 26°C in order to activate the microorganism population. Soil samples from Bahia State were incubated with50, 100, 150 e 200 mg of N per kg of soil as ammonium sulfate or urea and in the Minas Gerais soils it was evaluated the effect of liming on nitrification. Soil samples were incubated at 26°C during 15 days. Urea nitrified faster than ammonium sulfate. The sandy soil did not exhibit net nitrification following ammonium application, but

  5. Evaluation of skin entrance radiation dose in pediatric patients undergoing chest X-rays exams; Avaliacao da dose de entrada na pele em pacientes pediatricos submetidos a exames radiograficos do torax

    Energy Technology Data Exchange (ETDEWEB)

    Gabardo, Farly Piantini

    2016-07-01

    The aim of this work was to estimate the incident air kerma of lateral (LAT) and anterior-posterior (AP) together with posterior-anterior (PA) projection chest X-ray exams in one of the largest pediatric hospitals in Brazil. Dosimetric results are accompanied with the detailed analysis of patient characteristics and radiographer strategy. The exams of 225 (119 male and 106 female) patients were studied and 389 X-ray exams (200 AP/PA projections and 189 LAT projections) of pediatric patients were acquired. Patient thickness can be restored from age, height or weight with the uncertainty of ∼20-30%. Very slight correlation between the patient dose and thickness was observed with the difference in dose for patients of the same thickness reaching 4 times. By standardization of radiological protocols, it should be possible to keep dose within the intervals 50-100 μGy for LAT projection and 40-80 μGy for AP/PA projection. The dose values are lower than those recommended by major European guidelines to good practice. (author)

  6. Impact of electromechanical parameter variations in treatment volume doses and adjacent structures; Impacto da variacao dos parametros eletro-mecanicos nas doses do volume de tratamento e nas estruturas adjacentes

    Energy Technology Data Exchange (ETDEWEB)

    Morais, M.E.; Campos, A.M. [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil). Programa de Qualidade em Radioterapia]. E-mails: memorais@yahoo.com.br; amcampos@inca.gov.br; Goncalves, J. F. [Instituto de Oncologia e Radioterapia GV, Governador Valadares, MG (Brazil)]. E-mail: joelfgoncalves@yahoo.com.br; Ferreira, M.L. [Centro Radioterapico Gavea, Rio de Janeiro, RJ (Brazil)]. E-mail: mluciaf@yahoo.com

    2003-07-01

    ICRU Report 62 recommends that radiotherapy treatment dose should be prescribed in such a way that the dose to the target volume varies no more than 10%. In order to keep this goal, a very important role is played by the quality assurance (QA) of the treatment unit associated to the high level work of the personnel involved in planning and patient treatment. This paper shows the influence of the main electrical and mechanical linear accelerator parameters: field size, source-skin distance, gantry angle and light x radiation field coincidence in tumor volume and adjacent organ doses. We simulated a cubic tumor and a cubic adjacent critical organ in a cubic phantom and used a 3D Prowess system for planning. The treatment has been simulated for a 6 MV linear accelerator. We simulated two treatment planning: one using all the parameters inside their tolerance limits and another doubling these limits. The final results have show that, if the irradiation machine operates out of the tolerance limits, the dose variation in the planning target volume (PTV) can goes till {+-} 5,8% and in the critical adjacent organ till {+-} 7,7%. Therefore we concluded that, according to the complexity of the treatment, it can be necessary to reduce the tolerance levels advised by the IAEA/TECDOC - 1151. (author)

  7. Ionizing radiation dose control for workers in a nuclear plant working with unsealed sources; Controle da dose de radiacao ionizante para trabalhadores em uma instalacao radiativa com fontes nao seladas

    Energy Technology Data Exchange (ETDEWEB)

    Gerulis, Eduardo

    2006-07-01

    With the liberation of the use of the nuclear energy for peaceful applications, International Commission Radiological Protection, ICRP, founded in 1928, created a system of protection of the undesirable doses of ionizing radiation in 1958. This has been received by workers, members of the public and environment and hence it became possible for the introduction of these applications. This protection system is adopted by the International Agency of Energy Atomic, IAEA, that publishes recommendations in safety series, 88 and by the Comissao Nacional de Energia Nuclear, CNEN, which publishes these regulations. The international recommendations and national regulations were adapted and they need to be applied in this way. The present paper uses recommendations of the publication 75 from ICRP, of the publication 115 from 88 and regulations of the regulation NN 3.01 from CNEN to present, through radiological protection measures, the ionizing radiation dose control for workers in a nuclear plant that works in the research, production, division and packing of unsealed sources to be used in clinical applications. In that way it is possible to prevent appropriately the undesirable doses and to confirm the received doses. (author)

  8. Determination of gamma radiation dose for destruction of Salmonella spp. in chicken flesh.; Determinacao da dose de radiacao gama para a destruicao de Salmonella spp. em carne de frango

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Andreia Ferreira dos

    1997-07-01

    The aim of this study was to determinate: 1) the radio sensibility of Salmonella typhimurium ATCC 14028 in soy trypticase broth; 2) the radio sensibility of Salmonella typhimurium ATCC 14028 in chicken thigh and; 3) to recommend a radiation dose which can be non hazardous for human consumption

  9. Trans-nipple removal of fibro-glandular tissue in gynaecomastia surgery without additional scars: An innovative approach

    Directory of Open Access Journals (Sweden)

    R K Mishra

    2014-01-01

    Full Text Available Context: The established techniques that have been used to treat gynaecomastia are said to have relatively less patient satisfaction rate as they leave some visible scars or mild elevation over the nipple areola complex, resulting in aesthetically unsatisfactory results. Even the slightest elevation or smallest scar over nipple areola complex leave patients extremely self conscious and in a dilemma of having a second intervention to get rid of that blemish. Aims: The aim of the study is to achieve - A flat chest without adding a scar and with no chances of re-occurrence of the condition. This article suggests an innovative approach to address the problem. Materials and Methods: The author presents trans-nipple incision approach for the delivery of fibro-glandular tissue component following liposuction for maximum patient satisfaction. This method consists of a unique small criss-cross incision right on the nipple itself for retrieving any volume of tough fibro-glandular tissues. Between the duration of January 2012 to October 2013, 28 male patients of different ages were operated with this technique. Results: The surgery resulted in well-shaped, symmetric chest contour without any visible elevation or additional scars on nipple areola complex. No complications were noticed in any of the patients. Conclusions: The presented technique is proved to have a high patient satisfaction rate and to be promising method to achieve good aesthetic results in gynaecomastia surgery.

  10. Correlação entre métodos de avaliação da qualidade da dose de diálise La correlación entre los métodos de evaluación de la calidad de la dosis de diálisis Comparison between two methods for evaluation of the dialysis dose quality

    Directory of Open Access Journals (Sweden)

    Kelly Cristina Inoue

    2009-01-01

    Full Text Available OBJETIVO: Verificar a correlação entre o Kt/V calculado e o Kt/V-OCM. MÉTODOS: Estudo transversal, retrospectivo, com 14 pacientes submetidos a 106 hemodiálises com a máquina Fresenius 4008S, realizado numa Unidade de Terapia Intensiva para adultos, de um Hospital de Ensino do noroeste do Paraná, no período de novembro/2007 a abril/2008. RESULTADOS: Através do teste de Shapiro-Wilk, (p>0,05, foi constatado que não houve distribuição normal entre o "Kt/V calculado" e o "Kt/V da máquina". CONCLUSÃO: Pelo teste de Wilcoxon concluiu-se que houve diferença significativa (pOBJETIVO: Verificar la correlación entre el Kt/V calculado y el Kt/V-OCM. MÉTODOS: Estudio transversal, retrospectivo, con 14 pacientes sometidos a 106 hemodiálisis con la máquina Fresenius 4008S, realizado en una Unidad de Cuidados Intensivos para adultos, de un Hospital Docente del noroeste del Paraná, en el período de noviembre/2007 a abril/2008. RESULTADOS: A través del test de Shapiro-Wilk, (p>0,05, se constató que no hubo distribución normal entre el "Kt/V calculado" y el "Kt/V de la máquina". Por el test de Wilcoxon hubo diferencia significativa (pPURPOSE: To compare calculated Kt/V and Kt/V-OCM methods of dialysis dose. METHODS: This was a cross-sectional retrospective study with 14 patients who underwent 106 hemodialysis using Fresenius 4008S dialysis machine in the critical care unit of the "Noroeste Parana Teaching Hospital" from November 2007 to April 2008. RESULTS: Shapiro-Wilk test indicated that there was no normal distribution between the calculated Kt/V and the machine Kt/V (p>0.05. Wilcoxon test showed a statistically significant difference between the two measurements (p <.0001. CONCLUSION: There is a need for further studies that consider all factors involved with the online calculation of the urea depuration for the utilization of the Kt/V-OCM.

  11. Produtividade da biomassa de melissa em função de intervalo de cortes e doses de nitrogênio Biomass production of Lemon balm as a result of cutting interval and nitrogen levels

    Directory of Open Access Journals (Sweden)

    André May

    2008-09-01

    Full Text Available A espécie Melissa officinalis tem crescido em importância econômica no setor produtivo de plantas medicinais, contudo o nível de informações agronômicas a cerca da espécie é limitado. Dessa forma, foi instalado um experimento visando avaliar a influência do intervalo de cortes e de doses de nitrogênio sobre a produção de biomassa dessa espécie. O delineamento experimental utilizado foi o de blocos ao acaso, com três repetições, em esquema fatorial 4 x 4, sendo os fatores estudados o intervalo de cortes (30; 42; 54 e 66 dias e dose de nitrogênio (0; 60; 120 e 180 kg ha-1 de N. Foram avaliadas a altura da planta e massa seca da parte aérea. Observou-se maior altura da planta para maior intervalo entre corte. Maiores rendimentos de massa seca foram observados com a aplicação de 180 kg ha-1 de N, havendo uma resposta linear para a produção de massa seca com a aplicação de N.Cultivation of Melissa officinalis is increasing in economic importance in the market of medicinal plants, although the level of agronomic information concerning the specie is limited. To achieve those objectives, a trial was carried out to study the influence of cutting intervals and nitrogen levels in biomass production. The experimental design was in blocks with three replications in a 4 x 4 factorial cheme: cutting intervals (30; 42; 54 and 66 days and nitrogen (0; 60; 120 and 180 kg ha-1 of N. The characteristics of plant height and aerial part and accumulated dry mater were evaluated. Increasing the cutting intervals resulted in higher plants. The highest dry matter value was observed using 180 kg ha-1 of N, having a linear reply for the production of dry mass with the application of N.

  12. Use of the gamma radiation, in a dose of 0,4 kGy, on the storage temperature reduction of the banana nanica;Utilizacao da radiacao gama, na dose de 0,4kGy, na reducao da temperatura de armazenamento da banana nanica

    Energy Technology Data Exchange (ETDEWEB)

    Manoel, Luciana, E-mail: luciana_manoel@yahoo.com.b [Universidade Estadual Paulisa (UNESP), Botucatu, SP (Brazil). Fac. de Ciencias Agronomicas. Programa de Pos-graduacao em Energia na Agricultura; Vieites, Rogerio Lopes, E-mail: vieites@fca.unesp.b [Universidade Estadual Paulisa (UNESP), Botucatu, SP (Brazil). Fac. de Ciencias Agronomicas. Dept. de Gestao e Tecnologia Agroindustrial

    2009-07-01

    The aim was to evaluate the use of gamma radiation, in a dose of 0,4 kGy, on the storage temperature reduction of the banana 'Nanica'. The bananas 'Nanica' were harvested in the Arm Taperao, Brotas (SP) town, and sent to CBE (Companhia Brasileira de Esterilizacao-Cotia-SP) for irradiation and constitution of the following treatments: T1 (fruits irradiated at 0,4 kGy and stored at 16 +-1 deg C); T2 (fruits irradiated at 0,4 kGy and stored at 14 +-1 deg C); T3 (fruit irradiated ata 0,4 kGy and stored at 12+-1 deg C); T4 (fruits non-irradiated and stored at 16+-1 deg C); T5 (fruits non-irradiated and stored at 14+-1 deg C) and T6 (fruits non-irradiated and stored at 12+-1 deg C). The fruits were stored in B.O.Ds. of the Agroindustrial Management and Technology Department, with a relative humidity of 80+-5%. The experiment was divided in two groups: control group (post harvest conservation and disease incidence) and parcel group (soluble solids and pulp/peel). The analyses were performed in intervals of five days during a period of 25 days. The experimental design employed was completely randomized (DIC) by applying a factor of 2 x 3 x 6 (irradiation x temperature x time). The Tukey test with 5% of probability was used for comparison between means. The storage temperature of the bananas 'Nanica' was not reduce by irradiation. (author)

  13. Production and bromatologic composition of grass-mombaça (Panicum maximum Jacq., submitted to different sources and doses of acidity corrective / Produção e composição bromatológica da forragem do capim-mombaça (Panicum maximum Jacq., submetidos a diferentes fontes e doses de corretivo de acidez

    Directory of Open Access Journals (Sweden)

    Francisco Maximino Fernandes

    2010-04-01

    Full Text Available The experiment was carried in protected (greenhouse atmosphere, in University of Engineering, UNESP of Ilha Solteira-SP, with the objective of evaluating sources (limestone and calcium silicate slag and doses (0,0 – 0,5 – 1,0 – 1,5 – 2,0 times the recommended dose of corrective in the bromatologic composition, tillering and production of dry matter of the grass mombaça (Panicum maximum Jacq.. The lineation was completely randomized design, with four repetitions. It was evaluated the tiller number, the production of dry matter, the gross protein, neutral detergent fiber (NDF and acid detergent fiber (ADF. The corrective influenced the tillering in almost all of the countings. The limestone provided larger production of dry matter in the doses of 1,5 and 2,0 times the recommended dose. The bromatologic composition of the forage was not influenced by the corrective and doses.O experimento foi conduzido em ambiente protegido (estufa, na Faculdade de Engenharia, UNESP de Ilha Solteira, com o objetivo de avaliar fontes (calcário e escória silicatada e doses (0,0 – 0,5 – 1,0 – 1,5 – 2,0 vezes a dose recomendada de corretivos na composição bromatológica, perfilhamento e produção de matéria seca do capim-mombaça (Panicum maximum Jacq.. O delineamento experimental utilizado foi inteiramente casualizado, com quatro repetições. Avaliou-se o número de perfilhos, a produção de matéria seca e os teores de proteína bruta (PB, fibra em detergente neutro (FDN e fibra em detergente ácido (FDA. Os corretivos influenciaram o perfilhamento em quase todas as contagens. O calcário proporcionou maior produção de matéria seca nas doses de 1,5 e 2,0 vezes a dose recomendada. A composição bromatológica da forragem não foi influenciada pelos corretivos e doses utilizadas.

  14. Evaluation of repeated dose micronucleus assays of the liver and gastrointestinal tract using potassium bromate: a report of the collaborative study by CSGMT/JEMS.MMS.

    Science.gov (United States)

    Okada, Emiko; Fujiishi, Yohei; Narumi, Kazunori; Kado, Shoichi; Wako, Yumi; Kawasako, Kazufumi; Kaneko, Kimiyuki; Ohyama, Wakako

    2015-03-01

    The food additive potassium bromate (KBrO3) is known as a renal carcinogen and causes chromosomal aberrations in vitro without metabolic activation and in vivo in hematopoietic and renal cells. As a part of a collaborative study by the Mammalian Mutagenicity Study group, which is a subgroup of the Japanese Environmental Mutagen Society, we administered KBrO3 to rats orally for 4, 14, and 28 days and examined the micronucleated (MNed) cell frequency in the liver, glandular stomach, colon, and bone marrow to confirm whether the genotoxic carcinogen targeting other than liver and gastrointestinal (GI) tract was detected by the repeated dose liver and GI tract micronucleus (MN) assays. In our study, animals treated with KBrO3 showed some signs of toxicity in the kidney and/or stomach. KBrO3 did not increase the frequency of MNed cells in the liver and colon in any of the repeated dose studies. However, KBrO3 increased the frequency of MNed cells in the glandular stomach and bone marrow. Additionally, the MNed cell frequency in the glandular stomach was not significantly affected by the difference in the length of the administration period. These results suggest that performing the MN assay using the glandular stomach, which is the first tissue to contact agents after oral ingestion, is useful for evaluating the genotoxic potential of chemicals and that the glandular stomach MN assay could be integrated into general toxicity studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Safety analysis for the Abadia de Goias repository: alternative evaluation of the ingestion dose rate critical distance; Analise de seguranca para o repositorio de Abadia de Goias: avaliacao alternativa da distancia critica de taxa de dose de ingestao

    Energy Technology Data Exchange (ETDEWEB)

    Martin Alves, A.S. de; Passos, E.M. dos [NUCLEN, Rio de Janeiro, RJ (Brazil)

    1995-12-31

    An alternative calculation of the ingestion dose rate critical distance due to a hypothetical release of Cs-137 from the structure of the Repository of Abadia de Goias is presented. The release pathway considers the repository - groundwater region - well - and food chain. The main adopted modification comparing to the previous work is the inclusion of the convective and molecular diffusion terms in the radionuclide transport equation in addition to the radioactive decay term. (author). 6 refs, 1 tab.

  16. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams; Comparação da dose absorvida de dois protocolos de varredura tomográfica em exame de PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G., E-mail: fgpaiva92@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Santana, P.C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Mourão Filho, A.P. [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification.

  17. Development of methodology for assessment of absorbed dose and stopping power for low energy conversion electrons; Desenvolvimento de uma metodologia para estimativa da dose absorvida e do poder de freamento para eletrons de conversao de baixa energia

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ivan Pedro Salati de

    1995-08-01

    The evaluation of absorbed dose in the case of external and internalcontamination due to radionuclides is sometimes hard, because of the difficulties in the assessment of the absorbed dose caused by electrons with energy less than 100 KeV in mucous membrane. In this work, a methodology for assessment of absorbed dose and stopping power in VYNS (co-polymer of polivinyl chloride - acetate) absorbers, for the 62.5 KeV and 84-88 KeV energy {sup 109} Cd conversion electrons, working with a 4 {pi} proportional pressurized detector, is presented. In order to assure the reproducibility of measurement conditions, one of the detector halves has been used to obtain a spectrum of a thin {sup 109} Cd source, without absorber. The other half of the detector was used in concomitance to obtain spectra with different thicknesses if absorber. The absorbed energy was obtained subtracting each spectrum with absorber from the spectrum without absorber, which were stored in a microcomputer connected to signal processing systems by ACE type interface. The VYNS weight and thickness were evaluated using common radionuclide metrology procedures. As VYNS has characteristics similar to a tissue equivalent material, the results obtained are consistent with dosimetric concepts and have a good agreement with those of the literature. (author)

  18. Collective dose estimation in Portuguese population due to medical exams of diagnostic radiology and nuclear medicine; Estimativa da dose coletiva na populacao portuguesa devido a exames medicos de radiologia de diagnostico e de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Pedro; Vaz, Pedro [Instituto Tecnologico e Nuclear, Sacavem (Portugal). Instituto Superior Tecnico; Sousa, M. Carmen de [Instituto Portugues de Oncologia de Coimbra (Portugal); Paulo, Graciano; Santos, Joana [Escola Superior de Tecnologia da Saude de Coimbra (Portugal); Pascoal, Ana [Kings College Hospital, London (United Kingdom). Kings Health Partners; Cardoso, Gabriela; Santos, Ana isabel [Hospital Garcia de Orta, Almada (Portugal); Lanca, Isabel [Administracao Regional de Saude, Coimbra (Portugal); Matela, Nuno [Universidade de Lisboa (Portugal). Fac. de Ciencias. Instituto de Biofisica e Engenharia Biomedica; Janeiro, Luis [Escola superior de Saude da Cruz Vermelha Portuguesa, Lisboa (Portugal); Sousa, Patrick [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, Lisboa (Portugal); Carvoeiras, Pedro; Parafita, Rui [Medical Consult, SA, Lisboa (Portugal); Simaozinho, Paula [Administracao Regional de Saude, Faro (Portugal)

    2013-11-01

    In order to assess the exposure of the Portuguese population to ionizing radiation due to medical examinations of diagnostic radiology and nuclear medicine, a working group, consisting of 40 institutions, public and private, was created to evaluation the coletive dose in the Portuguese population in 2010. This work was conducted in collaboration with the Dose Datamed European consortium, which aims to assess the exposure of the European population to ionizing radiation due to 20 diagnostic radiology examinations most frequent in Europe (the 'TOP 20') and nuclear medicine examinations. We obtained an average value of collective dose of Almost-Equal-To 1 mSv/caput, which puts Portugal in the category of countries medium to high exposure to Europe. We hope that this work can be a starting point to bridge the persistent lack of studies in the areas referred to in Portugal, and to enable the characterization periodic exposure of the Portuguese population to ionizing radiation in the context of medical applications.

  19. The effect of prophylactic dose of a low molecular weight heparin on skin wound healing of rats Efeito da dose profilática de heparina de baixo peso molecular na cicatrização de feridas na pele de ratos

    Directory of Open Access Journals (Sweden)

    Ozdamar Fuad Oken

    2009-12-01

    Full Text Available PURPOSE: To investigate the effect of prophylactic dose of a low molecular weight heparin, enoxaparin, on skin wound healing of rats. METHODS: Forty rats were used for the study. Rats were randomly assigned to two equal groups. Experimental group received prophylactic dose of enoxaparin. Physiologic saline was administered to the control group. Parameters of wound healing of experimental and control groups were compared. For comparison of the groups in terms of fibrosis, vascularization, inflammation, epithelization, and tensile strength test (Newton. Mann-Whitney-U test was used because variables were categorical data (fibrosis, vascularization, inflammation and epithelization. Differences between groups were analyzed with independent samples t-test (tensile strength. Significance was set at pOBJETIVO: Investigar o efeito de dose profilática da heparina de baixo peso molecular, enoxaparina, na cicatrização de feridas na pele de ratos. MÉTODOS: Quarenta ratos foram utilizados para o estudo. Ratos foram distribuídos aleatoriamente a dois grupos iguais. O grupo experimental recebeu profilática de enoxaparina. Solução salina fisiologica foi administrada ao grupo controle. Foram comparados parâmetros de cicatrização dos grupos experimental e controle.Os grupos foram comparados em termos de fibrose, vascularização, inflamação, epitelização e força tensil (teste de Newton. Foi realizado o teste de Mann-Whitney-U para variáveis com dados categóricos (fibrose, cicatrização, inflamação e epitelização. Diferenças entre os grupos foram analisadas como amostras independentes pelo t-teste (força tensil. Significância foi fixada para p < 0,05. RESULTADOS: A ferida do grupo experimental apresentou força tensil diminuída significativamente (p < 0,001, o exame histopatológico revelou um significativo (p < 0,001 retardo na epitelização e diminuição na fibrose, cicatrização, inflamação (p < 0,001 no grupo experimental

  20. Radiolesão vascular como efeito deletério da braquiterapia intra-arterial com dose elevada de Samário-153 em coelhos hipercolesterolêmicos Vascular radiolesion as a deleterious effect of high-dose-rate intraarterial brachytherapy with Samarium-153 in hypercholesterolemic rabbits

    Directory of Open Access Journals (Sweden)

    Dalton Bertolim Précoma

    2006-10-01

    Full Text Available OBJETIVO: Este estudo tem por objetivo avaliar as alterações vasculares morfológicas e morfométricas induzidas pela braquiterapia com Samário-153 (153 Sm em coelhos hipercolesterolêmicos, com doses elevadas. MÉTODOS: Foram analisados 43 coelhos hipercolesterolêmicos, brancos, da raça New Zealand, e o total de 86 artérias ilíacas submetidas a lesão por balão de angioplastia. Divididos em três grupos: dois (GI irradiados com as doses de 15Gy (n=14 e 60Gy (n=36 e um grupo controle (n=36. Foram realizadas avaliação histológica morfométrica e análise histológica qualitativa para análise tecidual. RESULTADOS: Foram observadas uma redução significativa da neoproliferação intimal (NPI no GI 15 Gy (pOBJECTIVE: This study was designed to evaluate vascular morphological and morphometric changes induced by brachytherapy with samarium-153 (Sm-153 at high doses in hypercholesterolemic rabbits. METHODS: Forty-three New Zealand White hypercholesterolemic rabbits were analyzed, and the total of 86 iliac arteries underwent balloon angioplasty injury. The rabbits were divided into three different groups: two irradiation groups (IG assigned to 15 Gy (n=14 and 60 Gy (n=36 irradiation doses, respectively, and a control group (n = 36. Histomorphometric and qualitative histological analyses were performed for tissue evaluation. RESULTS: Significant reductions were found in neointimal proliferation (NIP (p< 0.0001, media area (MA (p<0.0001 and percent stenosis (p<0.0001 in the 15-Gy IG, compared to the other groups. The 60-Gy IG had the higher rate of NIP, increase in media and vessel areas (VA and percent stenosis. The 60-Gy IG also showed the greatest number of xanthomatous cells (60-Gy IG: 86.11% and 15-Gy IG: 14.29%, p<0.0001 and the highest amount of hyaline amorphous tissue (60-Gy IG:58.33% and 15-Gy IG:0%, p=0.0001 and vascular proliferation (60-Gy IG:30.56% and 15-Gy IG:0%, p=0.0221. No statistically significant differences were found

  1. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  2. Severidade da mela da soja causada por Rhizoctonia solani AG-1 IA em função de doses de potássio Severity of hte foliar blight of the soylean caused by Rhizoctonia solani AG-1 IA infunction of doses of potassium

    Directory of Open Access Journals (Sweden)

    Marco Antonio Basseto

    2007-03-01

    Full Text Available O fungo Rhizoctonia solani pertencente ao grupo de anastomose 1 IA (AG-1 IA é um dos patógenos mais importantes afetando a cultura da soja no Brasil. Este fungo causa queima da folha e/ou mela em soja, para a qual medidas de manejo cultural são consideradas alternativas importantes para controle antes do estabelecimento da doença. Há evidências de que a adubação potássica diminui substancialmente a severidade dos sintomas de várias doenças da soja como a queima foliar (Cercospora kikuchii, a seca da haste e da vagem (Phomopsis phaseoli var. sojae e o cancro da haste (Diaporthe phaseolorum f. sp. meridionalis. Apesar das evidências do efeito do potássio no controle de várias doenças da soja, não há informação na literatura sobre o efeito desse nutriente no controle da mela. A hipótese testada foi que a mela da soja pode ser controlada através de incrementos na adubação potássica. De maneira geral, concluiu-se que, sob condições de casa de vegetação, o incremento de K no solo não resultou no controle da mela da soja. É necessário, entretanto, confirmar esta observação conduzindo-se experimentos sob condições de campo, podendo-se incluir a avaliação do efeito da doença sob aspectos da produção.The fungus Rhizoctonia solani, belonging to anastomosis group 1IA (AG-1 IA is one of the most important pathogens affecting soybean in Brazil. This fungus causes aerial or foliar blight of soybean, and cultural measures are thought as important choices for the control before the establishment of the disease. Based on evidences that potassium amendments can substantially reduce the severity of several soybean diseases such as Cercospora leaf blight (Cercospora kikuchii, pod and stem blight (Phomopsis phaseoli var. sojae and stem canker (Diaporthe phaseolorum f. sp. meridionalis. Despite all evidence, there is no information in the literature about the effect of potassium controlling the soybean foliar blight. The

  3. Comportamento da alface americana em função do uso de doses e épocas de aplicação de boro em cultivo de inverno Behavior of crisp head lettuce as a result of doses and application times of boron in winter crop

    Directory of Open Access Journals (Sweden)

    Jony E. Yuri

    2004-09-01

    Full Text Available Avaliou-se a influência de doses de bórax sobre o rendimento e qualidade pós-colheita da alface americana (Lactuca sativa L., em três ensaios distintos conduzidos de junho a agosto/2002, no município de Três Pontas (MG. Utilizou-se o delineamento de blocos ao acaso com cinco doses de bórax (0,00; 0,75; 1,50; 2,25 e 3,00 kg ha-1 e quatro repetições, aplicadas em três diferentes épocas via foliar (14; 21 e 28 dias após o transplantio. A massa fresca total apresentou efeito quadrático no qual a dose de 1,58 kg ha-1 de bórax resultou em maior rendimento. Verificou-se variação de 795 a 829 g planta-1 entre as épocas de aplicação, sem diferirem estatisticamente entre si. A aplicação de 1,71 kg ha-1 de bórax possibilitou a obtenção de maior massa fresca comercial. O melhor resultado (563 g planta-1 foi obtido na aplicação aos 21 dias. Esta data também contribuiu na obtenção de maior circunferência da cabeça (41,7 cm, sendo significativamente superior à aplicação aos 28 dias (40,6 cm. Não foram observados efeitos significativos para o comprimento de caule entre os tratamentos. A dose de 1,55 kg ha-1 de bórax proporcionou uma melhor conservação da alface mantida durante 20 dias em câmara-fria.The influence of doses of borax on yield and post harvest quality of crisp head lettuce (Lactuca sativa L. was evaluated. Three distinct trials were conducted in Tres Pontas, Minas Gerais State, Brazil, from June to August 2002. The randomized block design with five doses of borax (0.00; 0.75; 1.50; 2.25 and 3.00 kg.ha-1 and four replicates, applied foliarly at different times (14; 21 and 28 days after transplanting was evaluated. The total fresh matter presented a quadratic effect, where the dose of 1.58 kg ha-1 of borax resulted in a greater yield. A range of 795 to 829 g plant-1 between different application times, with no statistical significant differences was observed. The application of 1.71 kg ha-1 of borax resulted in

  4. A double-blind randomized controlled trial of low doses of propranolol, nortriptyline, and the combination of propranolol and nortriptyline for the preventive treatment of migraine Estudo controlado, randomizado e duplo cego do uso de baixas doses de propranolol, nortriptilina e a combinação destas duas drogas no tratamento preventivo da migrânea

    Directory of Open Access Journals (Sweden)

    Renan B. Domingues

    2009-12-01

    Full Text Available Few trials have evaluated combination of two or more drugs in the preventive treatment of migraine. In this study three therapeutic regimens were compared: (a propranolol, at a dose of 40 mg per day, (b nortriptyline, at a dose of 20 mg per day, and (c the combination of these two drugs in these dosages. The groups were matched according to age, gender, and frequency of migraine attacks prior to treatment. The period of treatment was two months and the frequency and intensity of headache attacks of the 30 days pre-treatment period were compared with the frequency of headaches in the treatment period. Fourteen patients in groups A and B and sixteen patients in group C have completed the study. Treatment with propranolol, alone or in combination, was shown to be effective. Treatment with nortriptyline alone was not effective. All three therapeutic regimens were safe and side effects were minimal. The frequency of discontinuation of the study was the same in the 3 groups but no patient left the study due to adverse reactions. The combined therapy proved to be as safe as the monotherapy. Further studies evaluating this and other possible combinations of drugs in higher doses and for longer periods, should more clearly elucidate the role of combined therapy in the treatment of migraine.Poucos ensaios clínicos têm avaliado o tratamento preventivo da migrânea através da combinação de drogas. Neste estudo, três regimes terapêuticos foram comparados: (a popranolol, na dose de 40 mg por dia, (b nortriptilina, na dose de 20 mg por dia e (c combinação destas duas drogas nestas dosagens. Os grupos foram pareados de acordo com idade, sexo e freqüência de crises previamente ao tratamento. O período de tratamento foi de dois meses e a frequência e a intensidade das crises de cefaléia do período pré-tratamento foram comparadas com as do período de tratamento. Concluíram o estudo 14 pacientes do grupo A, 14 do grupo B e 16 do grupo C. Os

  5. Doses mammography: from phantom to the patient

    Energy Technology Data Exchange (ETDEWEB)

    Cross, P [Gammasonic Radiological Services, Pty., Ltd., Five Dock, NSW (Australia)

    1994-02-01

    While the use of a reference phantom is essential for dosimetry in acceptance testing and in regular quality control checks of a mammographic X-ray unit, it is also of importance to be able to estimate the patient dose in each individual investigation. Radiographic and physical data were analysed for a total of 212 women who were screened at three locations participating in a breast screening programme. The radiologists made estimates of the individual breast composition (%glandular/adipose ratio) at the film reporting sessions, and then the glandular doses were calculated by the auditor according to the NCRP 85 methodology. Arising from the data analysis of this dosimetry survey, a method is proposed to determine objectively patient breast composition from the photo-timed mAs for a given film optical density setting. This permits the NCRP calculations to be extended from breasts of 'average' (50/50) composition to breasts of individually determined composition. The diversity of the results between the three locations emphasises the need for regular audits of a mammographic X-ray unit's performance by an experienced radiological physicists, at least annually or after any major interventional service on the unit. 11 refs., 6 tabs., 4 figs.

  6. Radiation doses from radiation sources of neutrons and photons by different computer calculation; Tecniche di calcolo di intensita` di dose da sorgenti di radiazione neutronica e fotonica con l`uso di codici basati su metodologie diverse

    Energy Technology Data Exchange (ETDEWEB)

    Siciliano, F.; Lippolis, G.; Bruno, S.G. [ENEA, Centro Ricerche Trisaia, Rotondella (Italy)

    1995-11-01

    In the present paper the calculation technique aspects of dose rate from neutron and photon radiation sources are covered with reference both to the basic theoretical modeling of the MERCURE-4, XSDRNPM-S and MCNP-3A codes and from practical point of view performing safety analyses of irradiation risk of two transportation casks. The input data set of these calculations -regarding the CEN 10/200 HLW container and dry PWR spent fuel assemblies shipping cask- is frequently commented as for as connecting points of input data and understanding theoretic background are concerned.

  7. Study of noise sources of image for optimization of radiation doses in skull computerized tomography; Estudo das fontes de ruido da imagem para fins de otimizacao das doses na tomografia computadorizada de cranio

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, R.B.; Garos, K.A.C. [UNIFESP - Universidade Federal de Sao Paulo, SP (Brazil)]. E-mail: rbitelli@cfrh.epm.br

    2001-07-01

    Our goal was to evaluate the exposure factors that can change the image noise of head CT in different slices thicknesses. We have evaluated the images noise at several mAs varying from 50 to 800 mAs for 100, 120 and 140 kVp as tension values. The images uniformity were determined for all technical exposure conditions. We did not observed any important noise reduction for values up 200 mAs which can justify the increase of radiation doses through the increase of mAs. (author)

  8. Produtividade, qualidade e estado nutricional da beterraba de mesa em função de doses de nitrogênio Yield, quality and nutritional status of table beet affected by nitrogen rates

    Directory of Open Access Journals (Sweden)

    Leonardo A de Aquino

    2006-06-01

    Full Text Available O N é fundamental para a produtividade e a qualidade das hortaliças, todavia há carência de informações sobre seu uso em beterraba de mesa. Neste trabalho objetivou-se avaliar a produtividade, a qualidade e o estado nutricional nitrogenado da beterraba em função do N aplicado. Foram utilizadas quatro doses de N (0; 100; 200 e 400 kg ha-1de N, no delineamento blocos casualizados, com quatro repetições. Aos 28 dias após o transplante (dat, avaliou-se o estado nutricional nitrogenado por meio do teor de N-NO-3 nas folhas e clorofilômetro (SPAD. Na colheita (56 dat, foram avaliados: área foliar, produção de massas fresca (MF e seca (MS e teores de N-NO-3 e N-total nas folhas e raizes tuberosas e de sólidos solúveis totais nas raizes tuberosas. Com o incremento das doses de N, observaram-se aumentos para todas as características avaliadas. Aos 28 dias após o transplantio, o teor de N-NO-3 e unidades SPAD, correspondentes a 95% da produção máxima foram, respectivamente, de 2.575 mg kg-1 de MS e 44,7 unidades SPAD. Considerando-se apenas os aspectos quantitativo e econômico da produtividade de raizes, a dose de máxima eficiência econômica é de 343 kg ha-1 de N; todavia, ao serem considerados os aspectos quantitativo e qualitativo, a dose recomendada é de 193 kg ha-1 de N.Nitrogen is a fundamental element for the yield and quality of vegetables, but there is little information about its application to table beet crop. This work aimed to evaluate the yield, quality and nutritional status of N of the table beet as affected by the rate of N. Four rates of nitrogen were applied (0; 100; 200 and 400 kg ha-1 N in a randomized block design with four replicates. 28 days after the transplant (dat, the nutritional N status was evaluated through the leaves content of NO-3-N and chlorophyll by the SPAD meter. At harvest (56 dat, the traits evaluated were: leaf area, yield of fresh (FW and dry weight (DW of storage roots and leaves

  9. Emprego de altas doses de amiodarona via oral na reversão da fibrilação atrial no pós-operatório de cirurgia cardíaca High dose amiodarone for the reversion of atrial fibrillation during the postoperative period of cardiac surgery

    Directory of Open Access Journals (Sweden)

    João Carlos Vieira da Costa Guaragna

    1997-12-01

    Full Text Available OBJETIVO: Relatar a experiência no emprego de altas doses de amiodarona via oral (1800mg/d na reversão da fibrilação atrial (FA em pacientes submetidos à cirurgia cardíaca. MÉTODOS: Analisados, retrospectivamente, 80 pacientes que apresentaram FA no pós operatório de cirurgia cardíaca, constituindo 2 grupos: grupo A com 28 pacientes em uso de amiodarona e grupo B recebendo digital, sendo que este grupo foi subdividido no grupo C com 21 pacientes onde foi associada amiodarona, quando não houvesse reversão da arritmia em 48h. As diferenças foram consideradas significativas para um valor de PPURPOSE: To report our experience using high dose oral amiodarone (1,800mg/day for the reversion of atrial fibrillation to sinus rhythm in patients submitted to cardiac surgery. METHODS: We retrospectively analyzed the records of 80 patients who had atrial fibrillation during the postoperative period after cardiac surgery, initially divided in two groups: group A, 28 patients that used amiodarone, and group B composed of patients receiving digoxin. The latter group was divided further in a third group (C, with 21 patients in which amiodarone was associated with digoxin if there was no reversion of the arrhythmia after 48 hours of treatment. The observed differences were considered significant at P<0.05. RESULTS: Atrial fibrillation occurred in 19.4% of the patients submitted to surgery, predominating in males, 60 to 69 years-old. In group A there was reversion to sinus rhythm in 78.6% of the cases. In group B digoxin succeeded in 60%, and in group C 90% of the patients reverted to sinus rhythm. CONCLUSION: High dose oral amiodarone, alone or combined to digoxin, can be safe and effective for the treatment of atrial fibrillation after cardiac surgery.

  10. Doses de nitrogênio no acúmulo de nitrato e na produção da alface em hidroponia Nitrogen rates on nitrate accumulation and lettuce production in hydroponic system

    Directory of Open Access Journals (Sweden)

    Mônica LA Pôrto

    2012-09-01

    Full Text Available A produção da alface em hidroponia apresenta crescente expansão no Brasil, mas ainda ocorrem problemas de qualidade e risco de acúmulo de nitrato. O objetivo desse trabalho foi avaliar a produção da alface (cv. Elba e acúmulo de nitrato em hidroponia em função de níveis crescentes de N na solução nutritiva. Plantas de alface foram cultivadas em estufa telada da UFPB em Areia (PB, em solução nutritiva que continha níveis crescentes de N (11, 13, 15, 17, 19 e 21 mmol L-1 por 25 dias. O delineamento utilizado foi inteiramente casualizado com quatro repetições. Foram avaliadas a produção total (PTT, produção comercial (PCM e os teores de nitrato na matéria fresca da raiz, caule e folhas da alface. Não foram verificados efeitos significativos do incremento dos níveis de N na solução sobre a PTT e PCM, sendo obtidos valores médios de 357,3 e 352,5 g/planta, respectivamente. A elevação dos níveis de N em solução resultou em incrementos nos teores de nitrato em todas as partes da alface, obtendo-se na dose máxima teores de 659, 623 e 615 mg kg-1 de matéria fresca, para raiz, caule e folhas, respectivamente. Os máximos teores foliares de nitrato obtidos se encontraram abaixo do limite de risco para saúde humana.Lettuce production in hydroponic system presents growing expansion in Brazil, but still there are problems of quality and risk of nitrate accumulation. This work was carried out to evaluate the lettuce production and nitrate accumulation in hydroponic system depending on the increasing levels of nitrogen in the nutrient solution. The experiment was conducted in greenhouse of the Universidade Federal da Paraíba, Brazil. The lettuce plants were grown in nutrient solution containing increasing levels of N (11, 13, 15, 17, 19 and 21 mmol L-1 during a 25-day period. An entirely randomized design with four replications was used. Plant total yield (PTT, plant commercial yield (PCM and nitrate contents in the fresh

  11. Produtividade e componentes de produção da soja adubada com diferentes doses de fósforo, potássio e zinco Yield and production components of soybean fertilized with different doses of phosphorus, potassium and zinc

    Directory of Open Access Journals (Sweden)

    Affonso Celso Gonçalves Júnior

    2010-06-01

    Full Text Available O correto incremento da produtividade agrícola deve estar aliado ao avanço tecnológico no conhecimento das exigências nutricionais de cada cultura, proporcionando, dessa forma, o correto uso de insumos na propriedade agrícola. Com o objetivo de estudar a resposta de plantas de soja ao zinco (Zn em relação a diferentes doses de fósforo (P e potássio (K, foi realizado este experimento no município de Palotina-PR. O solo foi classificado como Argissolo Vermelho-Amarelo eutrófico. Os tratamentos foram arranjados em esquema fatorial 3x3, constituindo três formas de adubação com P2O5 e K2O: sem adubação, uma vez e duas vezes a recomendação de adubação pela análise de solo e três doses de Zn (0; 2 e 4 kg ha-1. Como fonte de nutrientes, foram utilizados fosfato bicálcico para P, cloreto de potássio para K e sulfato de zinco para Zn. As doses de Zn aplicadas não influenciaram, significativamente, a produtividade, não sendo justificada a sua suplementação na forma de adubação de base. Já a adubação com P2O5 e K2O provocou significativo aumento da produtividade e aumento do número de legumes por planta, com aumento das doses desses nutrientes no solo.The correct productivity increment must be allied to the technological advance in the knowledge of the nutritional requirements of each culture, thus allowing for the correct use of the inputs in the agricultural property. With the objective of studying the plants of soybean reply to zinc (Zn in relation to the different doses of phosphorus (P and potassium (K, this experiment was performed in the municipality of Palotina-PR. The soil was classified as typic hapludalf. The treatments were arranged in a 3x3 factorial scheme, constituting three fertilization forms with P2O5 e K2O: without fertilization, recommended dose and twice the recommended fertilization dose by the soil analysis and three Zn doses (0; 2 and 4 kg ha-1. Nutrient sources used were bicalcic phosphate for P

  12. Salivary gland acinar cells regenerate functional glandular structures in modified hydrogels

    Science.gov (United States)

    Pradhan, Swati

    Xerostomia, a condition resulting from irradiation of the head and neck, affects over 40,000 cancer patients each year in the United States. Direct radiation damage of the acinar cells that secrete fluid and protein results in salivary gland hypofunction. Present medical management for xerostomia for patients treated for upper respiratory cancer is largely ineffective. Patients who have survived their terminal diagnosis are often left with a diminished quality of life and are unable to enjoy the simple pleasures of eating and drinking. This project aims to ultimately reduce human suffering by developing a functional implantable artificial salivary gland. The goal was to create an extracellular matrix (ECM) modified hyaluronic acid (HA) based hydrogel culture system that allows for the growth and differentiation of salivary acinar cells into functional acini-like structures capable of secreting large amounts of protein and fluid unidirectionally and to ultimately engineer a functional artificial salivary gland that can be implanted into an animal model. A tissue collection protocol was established and salivary gland tissue was obtained from patients undergoing head and neck surgery. The tissue specimen was assessed by histology and immunohistochemistry to establish the phenotype of normal salivary gland cells including the native basement membranes. Hematoxylin and eosin staining confirmed normal glandular tissue structures including intercalated ducts, striated ducts and acini. alpha-Amylase and periodic acid schiff stain, used for structures with a high proportion of carbohydrate macromolecules, preferentially stained acinar cells in the tissue. Intercalated and striated duct structures were identified using cytokeratins 19 and 7 staining. Myoepithelial cells positive for cytokeratin 14 were found wrapped around the serous and mucous acini. Tight junction components including ZO-1 and E-cadherin were present between both ductal and acinar cells. Ductal and acinar

  13. Evaluation of the population dose to the UK population from the National Health Service breast screening programme

    International Nuclear Information System (INIS)

    Faulkner, K.; Wallis, M. G.; Neilson, F.; Whitaker, C. J.

    2008-01-01

    In the United Kingdom National Health Service Breast Screening Programme (NHSBSP), women aged between 50 and 70 y are invited for mammography every 3 y. Screening histories for each woman, over four screening rounds, were analysed. Data from five screening programmes were used to select 57 425 women into the study. Cases were selected on the basis of being between the ages of 50 and 53 at the start of the NHSBSP (i.e. between 1989 and 1992). Assessment of the outcome for each screening round for each woman involved assigning a simple outcome code. Each of the possible pathways through the four screening rounds was analysed. This comprises of 500 possible pathways. This data enabled the following information to be determined: (i) The number of times a woman attended the screening programme. (ii) The number of women referred for assessment at each screening round. This information may be used to deduce the population dose to this group of women averaged over four screening rounds. Patient doses have been monitored since the programme's inception and are typically 4.5 mGy for two-view screening. It is possible to determine the mean glandular dose received by this cohort of women over four screening rounds by multiplying the number of examinations by the mean glandular dose for a typical woman. Allowance has to be made for the number of projections taken at each screening round. Once a woman has been screened, she may be invited back for further assessment if an abnormality is found on her mammogram. A stereotactic attachment is used to determine where to place the biopsy device. Although the dose received during a normal screening mammogram is well known, the dose for a stereotactic procedure and other assessment procedures is less well known, partly because only a small part of the breast is directly irradiated during stereo-taxis. However, the woman may have multiple exposures during this stage. A prospective survey of doses was completed to deduce the mean

  14. Ensaio terapêutico com o pamoato de pirantel na ascaridíase e enterobíase em dose única: estudo da atividade sôbre demais helmintos

    Directory of Open Access Journals (Sweden)

    Lino Dias Rodrigues

    1970-12-01

    Full Text Available Os autores apresentam estudo de 90 pacientes medicados pelo Pamoato de Pirantel (Trans-1,4,5,6-Tetraidro-1-metil-1-2/2- (2-Tienil vinil/pirimidina. todos portadores de parasitoses intestinais, principalmente Ascaris lumbricoides e Enterobius vermicularis. Os pacientes foram divididos em dois grupos; o primeiro, constituído de 25 pacientes, recebeu a dosagem de 5mg/kg, dose única, numa só tomada e neste grupo apenas se estudou a atividade terapêutica na ascaridiase e enterobiase. No segundo grupo, de 65 pacientes, empregou-se a dose única de 10mg/kg numa só tomada e foi estudada, além da ação terapêutica na ascaridiase e enterobiase, possível atividade também sôbre outras helmintiases. Todos os pacientes após a medicação eram submetidos a 3 exames proctoparasitoscópicos de controle (no 7º, 15º, e 30º dia e nos casos prèviamente positivos para Enterobius vermicularis também se fêz controle no 7º e 15º dia pelo "Anal-swab". Comprovaram os autores no primeiro grupo, cura proctoparasitológica de 13 dos 18 casos de ascaridiase (72,2%; na enterobiase obtiveram cura de 61,5%, e na associação Ascaris-Enterobius obtiveram cura de 50,0% de ambos os parasitas, não havendo, entretanto, nenhum caso de falha total nos casos restantes. No segundo grupo, os resultados que obtiveram foram os seguintes: ascaridiase, 50 casos; curados, 40 (80,0%. Enterobiase, 22 casos; curados, 16 (72,7%. Necaturiase, 8 casos; curados, 5 (17,8%. Tricuríase, 41 casos; curados, 5 (12,1%. Estrongiloidiase, 5 casos; curado, 1 caso (20,0%. Associação Enterobius-Ascaris, 14 casos; cura total de ambos os parasitas em 10 casos (71,4%; 4 casos com cura parcial de um ou do outro parasita, não havendo falha total em nenhum caso. Empregaram comprimidos contendo 100 e 300mg da substância ativa, e forma liquida contendo 10mg da substância ativa por cm³. Efeitos colaterais reduzidos em número e em intensidade; o primeiro grupo 12,0% dos casos (epigastralgia

  15. Stability of the response and dependence of the optical signal as function of dose rate of the alanine gel dosimeter for electron clinic beams; Estabilidade da resposta e dependencia do sinal optico em funcao da taxa de dose do dosimetro alanina gel para feixes clinicos de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo; Dias, Daniel Menezes; Campos, Leticia Lucente, E-mail: cfsilva@ipen.b, E-mail: dmdias@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    This work evaluates the stability of response and the dependence on the optical response of dose rate of the alanine gel solution developed at the IPEN, Sao Paulo, Brazil, for possible future usage as 3D dosemeter in the medical area, as the area is lack of measure instrumentation for three dimension dose

  16. An audit of cervicovaginal cytology in a teaching hospital: Are atypical glandular cells under-recognised on cytological screening?

    Directory of Open Access Journals (Sweden)

    Crasta Julian

    2009-01-01

    Full Text Available Background: Cervical cytology screening for carcinoma of the cervix in India is mainly opportunistic in nature and is practiced mainly in urban centres. The effectiveness of cervical cytology screening depends on various factors. The quality of cervicovaginal cytology service is assessed by various quality indices and by cyto-histology correlation, which is the most important quality assurance measure. Aims: To describe the cervical cytology diagnoses, estimate the quality indices, and evaluate the discrepant cases on cytohistological correlation. Settings and Design: Retrospective observational study from a tertiary care centre in South India. Materials and Methods: Using a database search, all the cervicovaginal cytology reported during the period of 2002-2006 was retrieved and various diagnoses were described. The data was analysed to assess the quality indices. The cytohistologically discrepant cases were reviewed. Results: A total of 10,787 cases were retrieved, of which 98.14% were labeled negative and 1.36% were unsatisfactory for evaluation. A few (0.81% of the cases were labeled as squamous intraepithelial lesions and 0.38% as atypical squamous cells. The ASCUS: SIL ratio was 0.5. Cytohistological correlation revealed a total of ten cases with significant discrepancy. The majority of these were carcinomas that were misdiagnosed as atypical glandular cells. These cytology smears and the subsequent biopsies were reviewed to elucidate the reasons for the discrepancies. Conclusions: The cervical cytology service at our centre is well within the accepted standards. An increased awareness of cytological features, especially of glandular lesions, a good clinician-laboratory communication and a regular cytohistological review would further improve the diagnostic standards.

  17. An audit of cervicovaginal cytology in a teaching hospital: Are atypical glandular cells under-recognised on cytological screening?

    Science.gov (United States)

    Crasta, Julian A; Chaitra, V; Simi, Cm; Correa, Marjorie

    2009-04-01

    Cervical cytology screening for carcinoma of the cervix in India is mainly opportunistic in nature and is practiced mainly in urban centres. The effectiveness of cervical cytology screening depends on various factors. The quality of cervicovaginal cytology service is assessed by various quality indices and by cyto-histology correlation, which is the most important quality assurance measure. To describe the cervical cytology diagnoses, estimate the quality indices, and evaluate the discrepant cases on cytohistological correlation. Retrospective observational study from a tertiary care centre in South India. Using a database search, all the cervicovaginal cytology reported during the period of 2002-2006 was retrieved and various diagnoses were described. The data was analysed to assess the quality indices. The cytohistologically discrepant cases were reviewed. A total of 10,787 cases were retrieved, of which 98.14% were labeled negative and 1.36% were unsatisfactory for evaluation. A few (0.81%) of the cases were labeled as squamous intraepithelial lesions and 0.38% as atypical squamous cells. The ASCUS: SIL ratio was 0.5. Cytohistological correlation revealed a total of ten cases with significant discrepancy. The majority of these were carcinomas that were misdiagnosed as atypical glandular cells. These cytology smears and the subsequent biopsies were reviewed to elucidate the reasons for the discrepancies. The cervical cytology service at our centre is well within the accepted standards. An increased awareness of cytological features, especially of glandular lesions, a good clinician-laboratory communication and a regular cytohistological review would further improve the diagnostic standards.

  18. Evaluation of patient dose in some mammography centres in Iran

    International Nuclear Information System (INIS)

    Paknyat, A.; Samarin, E. R. P.; Jeshvaghane, N. A.; Paydar, R.; Fasaei, B.; Karamloo, A.; Khosravi, H. R.; Deevband, M. R.

    2011-01-01

    High diagnostic sensitivity and specificity while maintaining the least dose to the patient is the ideal mammography. The objective of this work was to evaluate patient dose and image quality of mammograms to propose corrective actions. The image quality for 1242 patient in 7 mammography facilities in Tehran city was evaluated based on selected image quality criteria using a three-point scale. Clinical image quality, the entrance surface air kerma, the average glandular dose and optical density of films for standard PMMA phantom of 4.5 cm thickness were evaluated. The results showed that up to 72 % of mammograms were in good condition to be diagnosed, and only about 3.4 % of the images were unacceptable or with suboptimal quality. The entrance surface air kerma values were in the range of 3.8-10.5 mGy, average glandular dose 0.5-1.8 mGy and optical density of films 0.74-2.03. The image quality evaluation after correction actions, periodic image quality evaluation and using the correct equipment certainly will improve patient dose. (authors)

  19. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    International Nuclear Information System (INIS)

    Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J; Cagnon, Christopher H; Goldin, Jonathan G; McNitt-Gray, Michael F; Primak, Andrew N; McCollough, Cynthia H; Stevens, Donna M; Cody, Dianna D

    2009-01-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  20. Metastatic Urothelial Carcinoma with Glandular Differentiation That Confirmed the Response by Autopsy Specimen to Second-Line mFOLFOX6 (Fluorouracil, Oxaliplatin, and Leucovorin plus Bevacizumab Chemotherapy

    Directory of Open Access Journals (Sweden)

    Taku Naiki

    2017-11-01

    Full Text Available The prognostic significance of glandular differentiation in urothelial carcinoma (UC is controversial, and thus far there is no established treatment strategy against metastasis of glandular component. We describe here a case of metastatic UC with glandular differentiation that had histological disappearance of adenocarcinoma components at autopsy after sequential chemotherapy with S-1 and cisplatin (CDDP and with mFOLFOX6 (fluorouracil, oxaliplatin, and leucovorin plus bevacizumab (mFOLFOX6+Bev. A 62-year-old Asian male was diagnosed with invasive UC with glandular differentiation (T2N0M0 by radical cystectomy and ileal conduit, and careful follow-up observation was made. Eight years after radical operation, peritoneal metastases occurred, and a biopsy specimen using colon fiber revealed high-grade adenocarcinomas with an immunohistochemical profile that included positivity for cytokeratin 7 (CK7 and negativity for cytokeratin 20 (CK20 and uroplakin, which was identical to the radical cystectomy specimen. Thus, he received combination chemotherapy consisting of S-1 and CDDP; however, the peritoneal metastasis worsened after 2 cycles. Therefore, second-line mFOLFOX6+Bev chemotherapy was performed for a total of 5 courses. In spite of this, the patient died, and the final diagnosis by autopsy was multiple metastases of infiltrating pure UC to the lung, bone, and peritoneum. Interestingly, there were no pathological findings of adenocarcinoma, and the immunohistochemical profile of the metastatic lesions was identical to that of the previous specimens from the bladder and colon. This suggests that sequential chemotherapy of S-1 and CDDP and second-line mFOLFOX6+Bev might be a feasible option in metastatic UC with glandular differentiation.

  1. Alterações nos atributos químicos de um Latossolo distroférrico decorrentes da granulometria e doses de calcário em sistemas plantio direto e convencional Changes of chemical soil characteristics due to doses and particle sizes of limestone in no-tillage and conventional systems

    Directory of Open Access Journals (Sweden)

    J. C. A. Mello

    2003-06-01

    Full Text Available Atualmente, percebe-se o interesse na calagem superficial, sem prévia incorporação, para instalação do sistema plantio direto (SPD. Dessa forma, objetivou-se determinar os efeitos de granulometria e doses de calcários no SPD, em fase de implantação, e no sistema de plantio convencional (SPC sobre o pH, H + Al, Ca2+ e Mg2+. O experimento foi realizado no ano agrícola de 1998/99, na FCA/UNESP-Botucatu (SP, em Latossolo Vermelho. O delineamento experimental foi de blocos ao acaso, com parcelas subsubdivididas e quatro repetições. As parcelas representaram os sistemas de plantio (SPD e SPC; as subparcelas, a granulometria dos calcários [grosso (PRNT = 56 % e fino (PRNT = 90 %], e as subsubparcelas, as doses de 2, 4 e 6 t ha-1 (calcário grosso e 1,2; 2,4 e 3,6 t ha-1 (fino. O solo foi amostrado, a 0-5, 5-10, 10-20 e 20-40 cm de profundidade, 1, 3 e 12 meses após a aplicação dos corretivos. A análise de variância não detectou interação tripla entre os fatores. A aplicação de calcário superficial no SPD, independentemente da granulometria e da dose, alterou positivamente os atributos químicos do solo (0-5 e 5-10 cm, 12 meses após a calagem. O corretivo continuou reagindo, independentemente do sistema de plantio, de forma intensa, mesmo após três meses. A aplicação de doses mais elevadas de calcário, com maior granulometria, sugeriu efeito residual prolongado.The interest of surface liming of soils on no-tillage system is increasing. The objective of this work was to evaluate the effects of different lime particle sizes and doses applied during the implantation phase of no-tillage and in conventional tillage systems on soil pH and H + Al, Ca2+, and Mg2+ contents. The experiment was carried out in 1998/99, on the experimental farm of São Paulo State University in Botucatu, São Paulo, Brazil, on a Red Distroferric Latossol (Oxisol. A split plot experimental design with four replications was used. The number of plots

  2. Induction of carcinomas in rat glandular stomach by direct X-irradiation of the stomach wall

    International Nuclear Information System (INIS)

    Kondratenko, A.G.; Bykorez, A.I.

    1980-01-01

    To induce carcinoma in rat stomach the direct irradiation of the organ wall with X-rays in a dose of 16.22 Gy has been used. In the period from the 8-th to the 15-th month after irradiation in mucous membrane of stomach foci of atrophy, sections of regenerating hyperplasia of glands and methaplasia of stomach gland cells in the epithelium of the intestine type have been observed. Highly differentiated adenocarcinomas growing through all the walls of stomach are found in 18.5% rats [ru

  3. Patient dose in digital mammography

    International Nuclear Information System (INIS)

    Chevalier, Margarita; Moran, Pilar; Ten, Jose I.; Fernandez Soto, Jose M.; Cepeda, T.; Vano, Eliseo

    2004-01-01

    In the present investigation, we analyze the dose of 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography system. Also, we evaluate the system calibration by analyzing the exposure factors as a function of breast thickness. The information relevant to this study has been extracted from the image DICOM header and stored in a database during a 3-year period (March 2001-October 2003). Patient data included age, breast thickness, kVp, mAs, target/filter combination, and nominal dose values. Entrance surface air kerma (ESAK) without backscatter was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs) included in the DICOM header. Mean values for the patient age and compressed breast thickness were 56 years (SD: 11) and 52 mm (SD: 13), respectively. The majority of the images was acquired using the STD (for standard) automatic mode (98%). The most frequent target/filter combination automatically selected for breast smaller than 35 mm was Mo/Mo (75%); for intermediate thicknesses between 35 and 65 mm, the combinations were Mo/Rh (54%) and Rh/Rh (38.5%); Rh/Rh was the combination selected for 91% of the cases for breasts thicker than 65 mm. A wide kVp range was observed for each target/filter combination. The most frequent values were 28 kVp for Mo/Mo, 29 kVp for Mo/Rh, and 29 and 30 kV for Rh/Rh. Exposure times ranged from 0.2 to 4.2 s with a mean value of 1.1 s. Average glandular doses (AGD) per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance for women in the age groups 50 to 64 and 40 to 49. This approach is based on the dependence of breast glandularity on breast thickness and age. The total mean average glandular dose (AGD T ) was calculated by summing the values associated with the pre-exposure and with the main exposure. Mean AGD T per exposure was 1.88 mGy (CI 0.01) and the mean AGD T per

  4. Dose surveys in two digital mammography units using DICOM headers

    International Nuclear Information System (INIS)

    Tsalafoutas, I.; Michalaki, C.; Papagiannopoulou, C.; Efstathopoulos, E.

    2012-01-01

    Background and objective: Digital mammography units store images in DICOM format. Thus, data regarding the acquisition parameters are available within DICOM headers, including among others, the anode/filter combination, tube potential and tube current exposure time product, compressed breast thickness, entrance surface air kerma (ESAK) and mean glandular dose (MGD). However, manual extraction of these data for the verification of the displayed values' accuracy and for dose survey purposes is time consuming. Our objective was to develop a method that enables the automation of such procedures. Materials and methods: Two hundred mammographic examinations (800 mammograms) performed in two digital units (GE, Essential) were recorded on CD-roms. Using appropriate software (DICOM Info Extractor) all dose related DICOM headers were extracted into a Microsoft Excel based spreadsheet, containing embedded algorithms for the calculation of ESAK and MGD according to Dance et al (Phys. Med. Biol. 45, 2000) methodology. Results: The ESAK and MGD values stored in the DICOM headers were compared with those calculated and in most cases were within ±10%. The basic difference among the two mammographic units is that, the older one calculates MGD assuming a breast composition 50% glandular-50% adipose tissue, while the newer one calculates the actual breast glandularity and stores this value in a DICOM header. The average MGD values were 1.21 mGy and 1.38 mGy, respectively. Conclusion: For the units studied, the ESAK and MGD values stored in DICOM headers are reliable. Utilizing tools for their automatic extraction provides an easy way to perform dose surveys. (authors)

  5. Nitrogen doses and weed control via intercropping with gliricidia for corn production Doses de nitrogênio e controle de plantas daninhas, através da consorciação com gliricídia, para produção de milho

    Directory of Open Access Journals (Sweden)

    P.S.L. Silva

    2010-01-01

    Full Text Available Many studies have demonstrated the beneficial influence of nitrogen doses on corn dry grain yield and green ear yield. Due to a growing concern with environmental degradation, many agricultural practices, adopted in the past, are being reexamined. With regard to weed control, strategies that employ mechanical control, including intercrops, are being the object of renewed interest. The purpose of this study was to evaluate the effects of the application of nitrogen doses (0, 40, 80, and 120 kg N ha-1; as ammonium sulfate and weed control on the growth, green ear yield, and grain yield of the AG 1051 corn cultivar. A randomized block experimental design with split-plots and nine replications was adopted. In addition to nitrogen rates, the AG 1051 cultivar was submitted to the following treatments, applied to subplots: no weeding, two hoeings (at 20 and 40 days after sowing, and intercropping with gliricídia (Gliricidia sepium. Gliricidia was sowed at corn planting, between the corn rows, using two seedlings per pit, in pits spaced 0.30 m apart. Gliricidia did not provide weed control, and gave plant growth, green ear yield and grain yield values similar to the no weeding treatment. However, regarding the number of mature ears got, intercropping with gliricidia did not differ from the two-hoeing treatment. Weed control did not have an effect on plant height and number of marketable, husked green ears, with the application of 120 kg N ha-1; indicating that nitrogen improved the corn's competitive ability. The two-hoeing treatment provided the best means for total green ears weight, number of marketable husked ears, both unhusked and husked marketable ear weight, grain yield and its components than the other treatments. Nitrogen application increased corn growth, green ear yield, and grain yield, as well as weed green biomass, but reduced the stand and growth of gliricidia.Muitos estudos demonstraram a influência benéfica da aplicação de doses

  6. Masculinização da tilápia do Nilo, Oreochromis niloticus, utilizando diferentes rações e diferentes doses de 17 a-metiltestosterona Masculinization of Nile tilapia, Oreochromis niloticus, using different diets and different doses of 17 a-methyltestosterone

    Directory of Open Access Journals (Sweden)

    Cleide Schmidt Romeiro Mainardes-Pinto

    2000-06-01

    Full Text Available Os objetivos deste estudo foram comparar a eficiência de duas rações 1 (NUTRAVIT e 2 (IP, ambas com 40% de proteína bruta, contendo o andrógeno sintético 17 a-metiltestosterona (MT, e analisar a dosagem mais efetiva desse hormônio na reversão sexual da Tilápia do Nilo, Oreochromis niloticus, por intermédio da análise histológica das gonadas e da sexagem dos exemplares. Foram utilizadas 9600 larvas de tilápia do Nilo, com 7 dias de vida, recebendo os seguintes tratamentos, por um período de 45 dias: A - 30 mg MT/kg de ração 1; B - 60 mg MT/kg de ração 1; C - 30 mg MT/kg ração 2; D - 60 mg MT/kg ração 2 e dois grupos controle: E e F, rações 1 e 2, respectivamente, sem hormônio. Os resultados dos testes qui-quadrado das freqüências de indivíduos machos e fêmeas analisados histológica e macroscopicamente mostram que o número de machos obtidos nos tratamentos A, B, C e D foi maior que o dos grupos controle e a dosagem de 60 mg MT/kg de ração, nas rações 1 e 2, foi mais eficiente, resultando em 98% de machos. Entre as rações, o tratamento com a ração 1 apresentou o melhor resultado, para a dosagem de 30 mg MT/ kg de ração, não havendo, pois, diferença entre rações para a dose de 60 mg MT/kg de ração.The objectives of the present study were to compare the efficiency of two diets: 1 (NUTRAVIT and 2 (IP, both with 40% of crude protein, containing the synthetic androgen hormone 17 a-methyltestosterone (MT and to analyze the most effective dose of this hormone on the sex reversal of Nile tilapia Oreochromis niloticus, throughout histological analysis of the gonads and sex determination of the samples. A total of 9600 Nile tilapia fries with seven days posthatching received the following treatments, per 45 days period: A- 30 mg MT/kg diet 1; B- 60 mg MT/kg diet 1; C- 30 mg MT/kg diet 2; D- 60 mg MT/kg diet 2 and two control groups, E and F with diets 1 and 2 hormone free, respectively. The results of chi

  7. Comparative study of dose estimation in the change a conventional mammography to digital mammography

    International Nuclear Information System (INIS)

    Vazquez Vazquez, R.; Otero Martinez, C.; Soto Bua, M.; Santamarina Vazquez, F.; Carril Iglesias, S.; Lobato Busto, R.; Luna Vega, V.; Mosquera Sueiro, J.; Sqanchez Garcia, M.; Pombar Camean, M.

    2011-01-01

    Mammographic studies are now one of the most demanding radiological because of its effectiveness in detecting breast cancer early. The introduction of digital mammography has been a major advance because it has overcome some of the limitations of conventional systems. Due to the nature of the radiosensitive glandular tissue becomes very important control of the dose given to patients. In the present study is to analyze the variations in dosimetry that can exist between a conventional mammography and digital mammography.

  8. Dose absorbed in adults and children thyroid due to the I123 using the dosimetry MIRD and Marinelli

    International Nuclear Information System (INIS)

    Vasquez, M.; Castillo, C.; Cabrera, C.; Sarachaga, R.; Castaneda, J.; Diaz, E.

    2014-08-01

    Using the dosimetry MIRD, and representation Cristy-Eckerman in the thyroid gland and organs of their bio-kinetics when I 123 (Iodine) is used, the study demonstrates that the absorbed dose by the gland of an adult, children, and newly born, is their auto-dose, independent of the compartments number of their bio-kinetics. The dosimetric contributions of the organs of their bio-kinetics are insignificant. Their results are not significantly different to those obtained by the formalism MARINELLI (auto-dose) when it uses a sphere like glandular representation. In consequence, the kinetic model corresponding to the glandular representation decreases to a compartment, where the gland can also be represented like a sphere. (Author)

  9. Segurança, imunogenicidade e eficácia protetora de duas doses da vacina RIX4414 contendo rotavírus atenuado de origem humana Safety, immunogenicity, and protective efficacy of two doses of RIX4414 live attenuated human rotavirus vaccine in healthy Brazilian infants

    Directory of Open Access Journals (Sweden)

    Eliete C. Araujo

    2007-06-01

    Full Text Available OBJETIVO: Determinar a segurança, imunogenicidade e eficácia de duas doses da vacina contra o rotavírus em lactentes brasileiros saudáveis. MÉTODOS: Foi realizado um estudo randomizado, multicêntrico, duplo-cego e controlado por placebo no Brasil, México e Venezuela. Os lactentes receberam duas doses orais de vacina ou placebo aos 2 e 4 meses de idade, juntamente com as imunizações de rotina, exceto a vacina oral contra poliomielite (VOP. O presente estudo relata apenas os resultados obtidos em Belém, Brasil, onde o número de indivíduos por grupo e os títulos da vacina viral foram os seguintes: 194 (104,7 unidades formadoras de focos - UFF, 196 (10(5,2 UFF, 194 (10(5,8 UFF e 194 (placebo. A resposta de anticorpos anti-rotavírus (anti-RV foi avaliada em 307 indivíduos. A gravidade clínica dos episódios de gastroenterite (GE foi determinada através de um escore com 20 pontos, onde um valor > 11 foi considerado como GE grave. RESULTADOS: As taxas de sintomas gerais solicitados foram semelhantes tanto nos indivíduos que receberam a vacina como naqueles a quem se administrou placebo. Aos 2 meses após a segunda dose, ocorreu resposta em termos de IgA sérica para RV em 54,7 a 74,4% dos vacinados. Não houve interferência na imunogenicidade das vacinas de rotina. A eficácia da vacina contra qualquer gastroenterite por rotavírus (GERV foi de 63,5% (IC95% 20,8-84,4 para a maior concentração (10(5,8 UFF. A eficácia foi de 81,5% (IC95% 44,5-95,4 contra GERV grave. Em sua maior concentração (10(5,8 UFF, a RIX4414 conferiu uma proteção de 79,8% (IC95% 26,4-96,3 contra GERV grave causada pela amostra G9. CONCLUSÕES: A RIX4414 foi altamente imunogênica com baixa reatogenicidade, e não interferiu na resposta sérica à difteria, tétano, coqueluche, hepatite B e antígenos Hib. Duas doses da RIX4414 conferiram proteção significativa contra a GE grave causada pelo RV.OBJECTIVE: To determine the safety, immunogenicity and

  10. The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl [Radiotherapiegroep, Arnhem (Netherlands); Smits, Geert A.H.J. [Department of Urology, Rijnstate Hospital, Arnhem (Netherlands); Oosterveld, Bernard J.; Janssen, Theo; Visser, Andries G. [Radiotherapiegroep, Arnhem (Netherlands)

    2016-08-01

    Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.

  11. Effect of lime levels and cultivars on yield and agroindustrial quality of sugarcane under Amazonic Oxisol = Efeito de doses de calcário e cultivares na produtividade e qualidade agroindustrial da cana-de-açúcar em solo da Amazônia.

    Directory of Open Access Journals (Sweden)

    Sílvio Vieira da Silva

    2014-12-01

    Full Text Available The cultivation of sugarcane in areas with acid soils and low fertility limits the potential yield and agroindustrial quality. The predominant soils in the Amazon region belong to the class of Oxisols and Ultisols, characterized by its high degree of weathering and low natural fertility. The objective of this study was evaluate the effect of different levels of limestone in phosphorus (P availability, yield and agroindustrial quality of different cultivars of sugarcane in very clayey Red-Yellow Oxisol under field conditions, in the Presidente Figueiredo region, State of Amazon. A randomized block design with three replications was used, the treatments were arranged in a split-plot, involving seven levels of liming (0, 1, 2, 3, 4, 5 and 6 t ha-1 and four cultivars of sugarcane (CO 997, RB 72454, RB 835019 and RB 835486. The yield and quality of agroindustrial sugarcane were not influenced by an interaction between liming and cultivars. Higher levels of liming contributed to increased levels of P in the soil and in the plant, and also for higher cane yield of sugarcane. Between cultivars, the RB 835486 presented the largest sugarcane yield and sugar content. = O cultivo da cana-de-açúcar em áreas de solos com características ácidas e de baixa fertilidade limita o potencial da produtividade e qualidades de seus produtos. Os solos predominantes na região Amazônica pertencem à classe dos Latossolos e Argissolos, caracterizados por seu alto grau de intemperismo, acidez e baixa fertilidade natural. Objetivou-se com o presente estudo avaliar o efeito de níveis de calcário na disponibilidade de fósforo (P, o rendimento e a qualidade agroindustrial de cultivares de cana-de-açúcar em um Latossolo Vermelho-Amarelo distrófico, na região de Presidente Figueiredo, no estado do Amazonas. Adotou-se o delineamento de parcelas subdivididas com três repetições, sendo as parcelas constituídas por sete doses de calcário (0, 1, 2, 3, 4, 5 e 6 t ha

  12. Radioproteção, dose e risco em exames radiográficos nos seios da face de crianças, em hospitais de Belo Horizonte, MG Radioprotection, doses and risks in the radiological assessment of paranasal sinuses in children, in hospitals of Belo Horizonte, MG

    Directory of Open Access Journals (Sweden)

    Marco Aurélio de Sousa Lacerda

    2007-12-01

    Full Text Available OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was

  13. The dose and image quality in mammography in Macedonia

    International Nuclear Information System (INIS)

    Gershan, V.

    2007-01-01

    Complete test of publication follows. Mean Glandular Dose (MGD), dose distribution, phantom and quality of the real mammogram were studied for the first time in Macedonia. The study was conducted to review the condition of mammography equipment, to access the dose and image quality in mammography practices in Macedonia.. The purpose was to find out the weak points in the mammography practices in order to suggest improvements in the practices and establish quality control procedures. Under evaluation were 12 monographic machines. MGD was estimated using Entrance Surface Air KERMA at the breast surface K f measured free in air and appropriate conversion factors. Dose survey was curried by measurement and calculated of the HVLs and radiation output for 25-32 kVp and keeping record of the clinical parameters (breast thickness, kVp, mAs). Image quality was evaluated using the Mammographic Accreditation Phantom Gammex 156, PMMA plates and test tool for film processing.

  14. Monoterpenes in the glandular trichomes of tomato are synthesized from a neryl diphosphate precursor rather than geranyl diphosphate.

    Science.gov (United States)

    Schilmiller, Anthony L; Schauvinhold, Ines; Larson, Matthew; Xu, Richard; Charbonneau, Amanda L; Schmidt, Adam; Wilkerson, Curtis; Last, Robert L; Pichersky, Eran

    2009-06-30

    We identified a cis-prenyltransferase gene, neryl diphosphate synthase 1 (NDPS1), that is expressed in cultivated tomato (Solanum lycopersicum) cultivar M82 type VI glandular trichomes and encodes an enzyme that catalyzes the formation of neryl diphosphate from isopentenyl diphosphate and dimethylallyl diphosphate. mRNA for a terpene synthase gene, phellandrene synthase 1 (PHS1), was also identified in these glands. It encodes an enzyme that uses neryl diphosphate to produce beta-phellandrene as the major product as well as a variety of other monoterpenes. The profile of monoterpenes produced by PHS1 is identical with the monoterpenes found in type VI glands. PHS1 and NDPS1 map to chromosome 8, and the presence of a segment of chromosome 8 derived from Solanum pennellii LA0716 causes conversion from the M82 gland monoterpene pattern to that characteristic of LA0716 plants. The data indicate that, contrary to the textbook view of geranyl diphosphate as the "universal" substrate of monoterpene synthases, in tomato glands neryl diphosphate serves as a precursor for the synthesis of monoterpenes.

  15. Identification and characterization of two bisabolene synthases from linear glandular trichomes of sunflower (Helianthus annuus L., Asteraceae).

    Science.gov (United States)

    Aschenbrenner, Anna-Katharina; Kwon, Moonhyuk; Conrad, Jürgen; Ro, Dae-Kyun; Spring, Otmar

    2016-04-01

    Sunflower is known to produce a variety of bisabolene-type sesquiterpenes and accumulates these substances in trichomes of leaves, stems and flowering parts. A bioinformatics approach was used to identify the enzyme responsible for the initial step in the biosynthesis of these compounds from its precursor farnesyl pyrophosphate. Based on sequence similarity with a known bisabolene synthases from Arabidopsis thaliana AtTPS12, candidate genes of Helianthus were searched in EST-database and used to design specific primers. PCR experiments identified two candidates in the RNA pool of linear glandular trichomes of sunflower. Their sequences contained the typical motifs of sesquiterpene synthases and their expression in yeast functionally characterized them as bisabolene synthases. Spectroscopic analysis identified the stereochemistry of the product of both enzymes as (Z)-γ-bisabolene. The origin of the two sunflower bisabolene synthase genes from the transcripts of linear trichomes indicates that they may be involved in the synthesis of sesquiterpenes produced in these trichomes. Comparison of the amino acid sequences of the sunflower bisabolene synthases showed high similarity with sesquiterpene synthases from other Asteracean species and indicated putative evolutionary origin from a β-farnesene synthase. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Comparative glandular trichome transcriptome-based gene characterization reveals reasons for differential (-)-menthol biosynthesis in Mentha species.

    Science.gov (United States)

    Akhtar, Md Qussen; Qamar, Nida; Yadav, Pallavi; Kulkarni, Pallavi; Kumar, Ajay; Shasany, Ajit Kumar

    2017-06-01

    The genes involved in menthol biosynthesis are reported earlier in Mentha × piperita. But the information on these genes is not available in Mentha arvensis. To bridge the gap in knowledge on differential biosynthesis of monoterpenes leading to compositional variation in the essential oil of these species, a comparative transcriptome analysis of the glandular trichome (GT) was carried out. In addition to the mevalonic acid (MVA) and methylerythritol phosphate (MEP) pathway genes, about 210 and 196 different terpene synthases (TPSs) transcripts were identified from annotation in M. arvensis and M. × piperita, respectively, and correlated to several monoterpenes present in the essential oil. Six isoforms of (-)-menthol dehydrogenases (MD), the last enzyme of the menthol biosynthetic pathway, were identified, cloned and characterized from the transcriptome data (three from each species). Varied expression levels and differential enzyme kinetics of these isoforms indicated the nature and composition of the product, as these isoforms generate both (-)-menthol and (+)-neomenthol from (-)-menthone and converts (-)-menthol to (-)-menthone in the reverse reaction, and hence together determine the quantity of (-)-menthol in the essential oil in these two species. Several genes for high value minor monoterpenes could also be identified from the transcriptome data. © 2017 Scandinavian Plant Physiology Society.

  17. Patient doses and radiation risks in film-screen mammography in Finland

    International Nuclear Information System (INIS)

    Servomaa, A.; Parviainen, T.; Komppa, T.

    1995-01-01

    Screen-film mamography is the most sensitive method for the early detection of breast cancer. Breast doses in mamography should be measured for several reasons, especially for the evaluation of patient risk in a screening programme, but also for the assessment and comparison of imaging techniques and equipment performance. In this study, the factors affecting patient doses were assessed by making performance and patient dose measurements; about 50 mammographic units used for screening were included in the study. The lifetime risk as a function of age at exposure was calculated using the average glandular dose, the relative risk model shown in the BEIR V report, and the breast cancer mortality in Finland. The mean surface dose of a 4.5 cm thick phantom was 6.3 mGy, and the mean glandular dose 1.0 mGy. Analysis of the surface dose with respect to film optical density, relative speed of film processing, sensitivity of image receptors, and antiscatter grid showed that the mean surface dose could be decreased by more than 50%. For the screened age group of 50 to 59 years, the risk of exposure-induced death (REID) of breast cancer is about 1.4 x 10 -6 mSv -1 , and the average loss of life expectancy due to the radiation-induced breast cancer deaths (LLE/REID) is about 9.5 years. (Author)

  18. Determinação da dose de radiação gama para reduzir a população de Salmonella spp em carne de frango Determination of gamma radiation doses to reduce Salmonella spp in chiken meat

    Directory of Open Access Journals (Sweden)

    A.F. Santos

    2003-08-01

    Full Text Available O consumo de carne de frango contaminada com Salmonella é uma causa importante de salmonelose em todo o mundo. Essa doença transmitida por alimentos, é um problema de saúde pública e causa de perdas econômicas substanciais. O processo de irradiação é um método eficiente de conservação de alimentos por reduzir o número de microrganismos patogênicos e deteriorantes, sem que as características organolépticas e nutricionais do alimento sejam alteradas significativamente. Os objetivos desta pesquisa foram determinar o valor D10 de Salmonella Typhimurium ATCC 14028, inoculada em sobrecoxas de frango, e recomendar uma dose de radiação para ser aplicada a esse alimento a fim de torná-lo seguro do ponto de vista microbiológico. O valor D10 foi calculado a partir da curva de sobreviventes dessa bactéria em sobrecoxas de frango, após terem sido expostas às doses de 0kGy; 0,1kGy; 0,2kGy; 0,3kGy; 0,5kGy; 0,6kGy; 0,7kGy e 0,8kGy. O valor D10 variou de 0,241kGy a 0,480kGy. Considerando o maior valor D10 e o maior nível de contaminação de Salmonella spp encontrado em sobrecoxas de frango - 0,4NMP/g - adquiridas em feiras livres da cidade de São Paulo, a dose de radiação gama recomendada para garantir a segurança do produto em relação à presença de Salmonella spp é de 3,8kGy.The consumption of chicken meat contaminated with Salmonella spp is an important cause of salmonellosis worldwide. This food-borne disease is a public health problem and causes substantial economical loss. Irradiation process is an effective method for food preservation because it causes no significant change in organoleptic and nutritional food characteristics and destroys pathogenic and spoilage microorganisms. D10 values were calculated through the number of survivors for S. Typhimurium ATCC 14028, inoculated in chicken thighs, after being irradiated with different doses of gamma radiation - 0.0kGy; 0.1kGy; 0.2kGy; 0.3kGy; 0.5kGy; 0.7kGy and 0.8kGy . D10

  19. Efeito de doses de torta de filtro e modo de aplicação sobre a produtividade e qualidade tecnológica da soqueira de cana-de-açúcar Effect of filter cake doses and methol of application on yield and technologycal quality of sugar cane ratoon

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Fávero de Fravet

    2010-06-01

    Full Text Available A expansão do setor sucroalcooleiro aumenta áreas de plantio, assim como volumes de resíduos (como a torta de filtro que podem ser utilizados na agricultura como fonte de nutrientes, reduzindo a contaminação ambiental e os custos com adubação, entretanto, faltam informações sobre modos de aplicação. Nesse contexto, conduziu-se este trabalho, com o objetivo de avaliar doses de torta de filtro e modos de aplicação (superficial na linha e incorporado na entrelinha sobre as variáveis tecnológicas e produtividade da cana soca. O experimento foi instalado em soqueira de cana-de-açúcar (SP 81-3250, cultivada em solo de textura argilosa, localizado no município de Goianésia/GO. O delineamento experimental utilizado foi em blocos ao acaso (DBC, com onze tratamentos e 5 repetições, em esquema fatorial 5 X 2 + 1 que correspondem a 5 doses crescentes de torta de filtro (0, 10, 20, 40 e 80 t ha-1, combinadas a 2 modos de aplicação (na linha superficial e na entre linha incorporada e um tratamento adicional correspondente à adubação mineral da Usina Jalles Machado S.A.. A aplicação de torta de filtro na cana-soca na dose de 70 t ha-1 proporcionou a maior produção de colmos de cana-de-açúcar, independentemente do modo de aplicação.The expansion of sugarcane (Saccharum officinarum L. cultivation for the production of sugar or ethanol has increased cultivated land as well as the volume of residues (such as filter cake that may be used in agriculture as a nutrient source, reducing environmental contamination and fertilization costs. However, there is a lack of information about the best way of application. In this way, the objective of the present work was to evaluate the effect of the filter cake dose and the application method (on the ground in the row and incorporated between rows on the technological variables and ratoon yield. The experiment was installed on a sugar cane ratoon (SP 81-3250, cultivated in clay soil in the

  20. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis.

    Science.gov (United States)

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21-24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis.

  1. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis

    OpenAIRE

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21-24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined w...

  2. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis.

    Directory of Open Access Journals (Sweden)

    Rongyan Fan

    Full Text Available The medicinal plant Xanthium strumarium L. (X. strumarium is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs are a class of 21-24 nucleotide (nt non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis.

  3. Evaluation of radon and their daughters concentration and estimative of effective dose in a waste deposits at the ore treatment unity of INB/Pocos de Caldas, Brazil; Avaliacao da concentracao de radonio e seus filhos e estimativa de dose efetiva em um deposito de rejeitos na unidade de tratamento de minerios da INB/Caldas

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Marcelino V.A.; Garcia Filho, Oswaldo; Antunes, Marcos M.; Junior, Joao V.S.; Py Junior, Delcy A., E-mail: marcelino@inb.gov.b, E-mail: wspereira@inb.gov.b, E-mail: ogarcia@inb.gov.b, E-mail: antunes@inb.gov.b, E-mail: Joao@inb.gov.b, E-mail: delcy@inb.gov.b [Industrias Nucleares do Brasil (UTM/INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Pereira, Wagner S. [Industrias Nucleares do Brasil (UTM/INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Universidade Federal Fluminense (IB/UFF), Niteroi, RJ (Brazil). Inst. de Biologia. Lab. de Radiobiologia e Radiometria Pedro Lopes dos Santos

    2011-10-26

    This paper conducts a surveillance of radon and their short half-life daughters gas concentration, inside the warehouse due to these gas inhalation. The results showed that the average concentration inside the warehouse ix approximately 700 Bq/m{sup 3} and the effective dose of an IOE, related to that concentration would be 5.0 mSv/year, therefore being 4 times lower than the established limit of 20 mSv/year

  4. Aerial gamma spectrometry of the uranium province of Lagoa Real (Caetite, BA, Brazil): go environmental aspects and distribution of the absorbed dose in the air; Espectrometria gama aerea da provincia uranifera de Lagoa Real (Caetite, BA): aspectos geoambientais e distribuicao da dose absorvida no ar

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Esau Francisco Sena

    2006-07-01

    In the present study, it was analyzed the surface concentrations of the natural radioelements K, U and Th, as well as the absorbed dose rate in air caused by gamma radiation from the Lagoa Real uranium province, which is located at the center southern portion of Bahia State and comprises an area of approximately 4.600 Km{sup 2}. Data from the airborne gamma ray spectrometric survey of the region (Sao Timoeo Project) carried out in 1979, was used in this study. Besides, recent data of U, Th and absorbed dose rates from the Environmental Monitoring Program of the uranium concentration plant (URA), operated in the region by the Brazilian Nuclear Industries (INB), were used with the aim of inter compare the sampling points in the same geo referenced area. Imaging geo processing software's give support to frame maps of surface concentrations and ternary maps, as well as allow the integration of these with other themes (e.g. hydrology, geology, pedology) favouring the interpretation of geo environmental process from the radioactive cartography. Considering the whole study area, it was obtained the following mean values: absorbed dose rate in air (61,08 nGy.h{sup -1}), Potassium (1,65 % K) , Uranium (3,02 ppm eU) and thorium (18,26 ppm eTh). The geological unities bounding the uranium anomalies were placed in the areas characterized by the highest values of radioelements and, as expected, the major dose levels. The use of ternary maps coupled with the geology and hydrology allowed distinguishing the relationship between the surface distribution of natural radioelements and the geo environmental aspects, including the influence of the catchment in their transport and migration. (author)

  5. Aerial gamma spectrometry of the uranium province of Lagoa Real (Caetite, BA, Brazil): go environmental aspects and distribution of the absorbed dose in the air; Espectrometria gama aerea da provincia uranifera de Lagoa Real (Caetite, BA): aspectos geoambientais e distribuicao da dose absorvida no ar

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Esau Francisco Sena

    2006-07-01

    In the present study, it was analyzed the surface concentrations of the natural radioelements K, U and Th, as well as the absorbed dose rate in air caused by gamma radiation from the Lagoa Real uranium province, which is located at the center southern portion of Bahia State and comprises an area of approximately 4.600 Km{sup 2}. Data from the airborne gamma ray spectrometric survey of the region (Sao Timoeo Project) carried out in 1979, was used in this study. Besides, recent data of U, Th and absorbed dose rates from the Environmental Monitoring Program of the uranium concentration plant (URA), operated in the region by the Brazilian Nuclear Industries (INB), were used with the aim of inter compare the sampling points in the same geo referenced area. Imaging geo processing software's give support to frame maps of surface concentrations and ternary maps, as well as allow the integration of these with other themes (e.g. hydrology, geology, pedology) favouring the interpretation of geo environmental process from the radioactive cartography. Considering the whole study area, it was obtained the following mean values: absorbed dose rate in air (61,08 nGy.h{sup -1}), Potassium (1,65 % K) , Uranium (3,02 ppm eU) and thorium (18,26 ppm eTh). The geological unities bounding the uranium anomalies were placed in the areas characterized by the highest values of radioelements and, as expected, the major dose levels. The use of ternary maps coupled with the geology and hydrology allowed distinguishing the relationship between the surface distribution of natural radioelements and the geo environmental aspects, including the influence of the catchment in their transport and migration. (author)

  6. Entomology contribution in animal immunity: Determination of the crude thoraxial glandular protein extract of Stomoxys calcitrans as an antibody production enhancer in young horses

    Directory of Open Access Journals (Sweden)

    L. Rumokoy

    2017-12-01

    Full Text Available This experiment was conducted to evaluate the level of antigens protein contained in the crude thoraxial glandular protein (TGP extract of Stomoxys calcitrans which function as immunity enhancer in young horses. The detection of protein content of the thoraxial glandular samples was performed by using a spectrophotometer Nano Drop-1000. This result showed that the lowest level of antigen protein was 0.54 mg/mL, the highest was 72 mg/mL, and the average was 0.675 mg/mL. Six foals were used and divided into two groups. The first group was treated with a solution of 100 μg of TGP by subcutaneous injection, the other group acted as control. The TGP extract was injected on the first day of the experiment. Three ml of blood were sampled from the jugular vein on the 14th day after TGP injection. The blood sampled was centrifuged and its serum placed in micro-tubes to observe the IgG level. The injection of TGP had a significant effect on the IgG level of the experiment animals (P<0.05. This experiment emphasized an important relation between entomology and animal husbandry; health improvement in the young animals was observed after the injection of the insect antigen, so it can be concluded that crude thoraxial glandular proteins of S. calcitrans can be used to improve the immunoglobulin-G circulation in foals.

  7. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme.

    Science.gov (United States)

    Timmermans, Lore; De Hauwere, An; Bacher, Klaus; Bosmans, Hilde; Lemmens, Kim; Bleyen, Luc; Van Limbergen, Erik; Martens, Patrick; Van Steen, Andre; Mortier, Griet; Van Herck, Koen; Thierens, Hubert

    2014-08-01

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30% in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. • Performance parameters showed no major differences after digitalisation to CR or DR. • Transition from SFM to CR results in a higher mean glandular dose. • Transition from SFM to DR results in a lower mean glandular dose.

  8. Dose reduzida de clethodim no controle de papua na cultura da soja, em função da época de aplicação Reduced rate of clethodim for alexandergrass: control in soybeans as a function of application time

    Directory of Open Access Journals (Sweden)

    Nilson G. Fleck

    1997-01-01

    Full Text Available Foi realizado um experimento a campo em Eldorado do Sul, RS, no ano agrícola de 19 94 /9 5, para avaliar o controle de papuã (Brachiaria plantaginea (Linck Hitchc., que ocorreu numa população média de 95 plantas/m2. Foi avaliado o herbicida clethodim à dose-plena (120g/ ha e à meia-dose (60g/ha. A cultivar de soja utilizada foi RS-7 Jacuí e usado o delineamento experimental em blocos casualizados com quatro repetições. Os tratamentos foram aplicados aos 14, 21, 28 e 35 dias após a emergência da soja (DAE. Foram mantidas testemunhas capinadas, com operações iniciadas nas mesmas épocas de aplicação do herbicida, e uma testemunha infestada durante todo o ciclo da cultura. O controle foi avaliado visualmente, em três ocasiões, através de escala percentual. Os graus de controle de papua obtidos à dose-plena foram equivalentes entre si quando aplicado nas três primeiras épocas, com eficiência entre 95 e 98% na última avaliação. A meia-dose mostrou, para as três primeiras épocas de aplicação, resultados semelhantes aos de doseplena, porém em níveis um pouco inferiores, situando-se entre 85 e 95% o controle obtido na última avaliação. O controle do papuã foi mediano quando clethodim foi aplicado aos 35 DAE, tanto par a dose-plena quanto para meiadose. Quanto ao rendimento de grãos, não houve diferença estatística significativa entre os tratamentos em suas várias modalidades, embora todos tenham superado a testemunha infestada, com incrementos na produtividade de grãos entre 73 e 10 5% . O experimento permite concluir pela viabilidade da utilização de meiadose de clethodim para o controle de papua em soja, realizando as aplicações preferencialmente até a quarta semana após a emergência da cultura.A field trial was carried out in Eldorado do Sul, RS, during the 1994/95 growing season to evaluate Alexandergrass (Brachiaria plantaginea (Linck Hitchc control, that occurred with na average population of 95

  9. Use of different simulators to quality evaluation of image quality in digital mammography; Utilizacao de diferentes simuladores na avaliacao da qualidade da imagem em mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Leslie S.; Coutinho, Celia M.C., E-mail: leslie@ird.gov.br, E-mail: celia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Magalhaes, Luis A.G.; Almeida, Carlos Eduardo de, E-mail: luisalexandregm@hotmail.com, E-mail: cea71@yahoo.com.br [Universidade do Estado do Rio de Janeiro (LCR/UERJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Ciencias Radiologicas

    2013-11-01

    In this study, the digital images were acquired with different exposure simulators to evaluate the quality of the image, noting the tumor mass detection, microcalcification fiber and representing regions of interest during mammography. The technical parameters of exposure depends on the thickness and composition of the breast, thus affecting the dose and image quality. The simulators were used: ACR, SBP 1054, BREAST PHANTOM CIRS and for evaluation of image quality, as well as measures kerma incident on the entrance surface (Ki) and calculating the mean glandular dose (MGD)

  10. Mobilidade de potássio em solos decorrente da adição de doses de cloreto de potássio Potassium movement in soils as related to potassium chloride application

    Directory of Open Access Journals (Sweden)

    Lisiane Silva das Neves

    2009-02-01

    Full Text Available Em solos recentemente fertilizados, as plantas absorvem os nutrientes que estão principalmente nas adjacências dos grânulos, cuja composição química é pouco conhecida. Este trabalho teve como objetivo avaliar o gradiente de concentração de K e a concentração eletrolítica a partir da região fertilizada com KCl em cinco solos, que tinham quantidades variáveis de argila (95 a 569 g kg-1 e de matéria orgânica (13 a 54 g kg-1. Os tratamentos consistiram de doses de KCl equivalentes a 0, 50, 100 e 200 kg ha-1 de K2O. Para obter as quantidades a serem aplicadas, considerou-se que essas doses seriam adicionadas sobre a superfície do solo, em linhas distanciadas de 0,70 m, e atingiria uma faixa de 2,5 cm, ou seja, entrariam em contato com 357 m² ha-1 de solo. Cada unidade experimental foi formada pela união de dois tubos horizontais de PVC, cada um com 7,0 cm de diâmetro e 9,0 cm de comprimento, preenchida com solo. Os grânulos de KCl foram distribuídos uniformemente entre duas folhas circulares de papel-filtro (7,0 cm de diâmetro, que foram colocadas na superfície de junção dos dois tubos. O gradiente de concentração de K nos solos foi quantificado por meio da concentração do K trocável (Mehlich-1 em diferentes distâncias a partir do local de aplicação dos grânulos. A movimentação de K variou com o tipo de solo, aumentou com a dose de KCl e foi menor no solo que tinha mais areia e menos matéria orgânica. Após 7 dias, com a maior dose de KCl aplicada (200 mg kg-1 K2O, a movimentação de K foi maior no Cambissolo Húmico léptico CHat (8,4 cm e menor no Latossolo Vermelho distrófico LVd (6,4 cm. A amplitude de concentração de K no centímetro mais próximo do adubo variou de 9.800 a 16.475 mg kg-1; na camada distante de 4,0 a 5,0 cm dos grânulos, o K variou de 244 a 2.254 mg kg-1. A condutividade elétrica não atingiu valores prejudiciais ao processo germinativo de espécies com média tolerância a sais

  11. The Cellient automated cell block system is useful in the differential diagnosis of atypical glandular cells in Papanicolaou tests.

    Science.gov (United States)

    Xing, Wei; Hou, April Y; Fischer, Andrew; Owens, Christopher L; Jiang, Zhong

    2014-01-01

    Atypical glandular cells (AGC) is a very important diagnosis in gynecological cytology. In the current study, the authors investigated the usefulness of Cellient cell blocks (CB) for characterizing AGC on Papanicolaou (Pap) tests. A total of 148 patients with an AGC diagnosis based on Pap tests by cytotechnologists and referred to cytopathologists were studied. Among these patients, there were 68 patients with CB preparations and 80 patients with Pap tests only (TP-AGC group). Follow-up results by Pap tests or biopsies were obtained in 117 of 148 patients. The median follow-up was 13 months (range, 1 month-36 months). Of the 68 patients with CBs, 31 (46%) were reclassified as negative for dysplasia or low-grade intraepithelial lesion; 30 patients (44%) retained a diagnosis of AGC (CB-AGC group); and 7 patients (10%) were given specific diagnoses of high-grade intraepithelial lesion (3 patients), endocervical adenocarcinoma in situ (1 patient), and invasive adenocarcinoma (3 patients). On follow-up, the CB-AGC group was found to have a significantly lower rate of negative/low-grade squamous intraepithelial lesion diagnoses compared with the TP-AGC group (55% vs 85%; P= .006). The CB-AGC group had a significantly higher rate of endocervical or endometrial adenocarcinoma compared with the TP-AGC group (36% vs 8%; P= .003) at the time of follow-up. The rates of high-grade squamous intraepithelial lesion were not found to be statistically different between these 2 groups (9% vs 7%; P= .66). The Cellient CB is a useful technique to further categorize a diagnosis of AGC on Pap tests. Using the Cellient CB system, the pathologist has the ability to improve the diagnostic accuracy of AGC so that unnecessary colposcopic evaluation or biopsies can be avoided. © 2013 American Cancer Society.

  12. Staying at the crossroads: assessment of the potential of serum lithium monitoring in predicting an ideal lithium dose Em uma encruzilhada: potencial do nível plasmático de lítio como preditor da dose ideal

    Directory of Open Access Journals (Sweden)

    Thiago Zaqueu Lima

    2008-09-01

    ção normal. Coletou-se amostras de sangue para dosagem plasmática do lítio. RESULTADOS: Os animais alimentados com a ração com 0,255% de cloreto de lítio fizeram mais rearing no campo aberto e tiveram uma maior freqüência de entradas nos braços do labirinto elevado que os animais que ingeriram a dose mais alta. Apesar disso, verificou-se níveis plasmáticos de lítio semelhantes em ambos os grupos. DISCUSSÃO: A variação nos comportamentos destarte a presença de níveis plasmáticos semelhantes sugere que as diferentes doses produziram diferentes concentrações cerebrais não detectadas pela medida plasmática. CONCLUSÃO: Medidas da concentração plasmática de lítio não permitem prever de forma completa seus efeitos comportamentais.

  13. Componentes da Produção de Forragem em Pastagens dos Capins Tanzânia e Mombaça Adubadas com Quatro Doses de NPK Components of Herbage Production of Tanzania and Mombaça Pastures Fertilized with Four Doses of NPK

    Directory of Open Access Journals (Sweden)

    Danilo Gusmão de Quadros

    2002-06-01

    Full Text Available O trabalho foi conduzido na FCAV-Unesp, em Jaboticabal-SP, para avaliar os efeitos de quatro doses combinadas de NPK sobre os componentes da produção e das perdas de matéria seca (MS em pastagens dos cultivares Tanzânia e Mombaça de Panicum maximum Jacq., manejadas com 28 dias de descanso e com altura média de 30 cm de resíduo pós-pastejo. As avaliações foram realizadas em parcelas de 96 m² segundo um fatorial 2 (cultivares x 4 (doses de NPK, em blocos completos ao acaso, com três repetições. As adubações estudadas corresponderam ao decréscimo em 30 % e aos acréscimos em 30 e 60 % de uma dose "padrão" com 145; 21,6 e 180 kg/ha de N, P2O5 e K2O, respectivamente (referente a 1,2; a 0,08; e a 1,2 % de N, P e K na MS, com produção estimada em 12000 kg/ha. A MS verde (MSV em pré-pastejo e no resíduo aumentou linearmente com a adubação, com maiores valores obtidos para o cv. Mombaça (9183 e 5227 kg/ha, respectivamente do que para o cv. Tanzânia (6275 e 3808 kg/ha, respectivamente. A participação de lâminas foliares na MSV em pré-pastejo foi menor no cv. Tanzânia (51 % do que no cv. Mombaça (54 %. A densidade de perfilhos não variou com a adubação. O aumento do peso de perfilho com a elevação das doses de NPK resultou em maiores produções de MSV. A MS senescida (média de 3108 kg/ha de MS não diferiu entre cultivares. De modo geral, quanto maior a dose de adubo aplicado, maiores foram a taxa de acúmulo diário de MSV e a MSV perdida por pisoteio. O cv. Mombaça apresentou maior potencial de resposta à adubação do que o cv. Tanzânia, com taxas de lotação de 6,2 e 4,0 UA/ha, respectivamente.The experiment was conducted at the FCAV-Unesp, Jaboticabal-SP, to evaluate the effects of the fertilization with four doses of NPK on the components of dry matter (DM and losses by trampling of two cultivars of Panicum maximum Jacq. (Tanzania and Mombaça under grazing, having a rest period of 28 days and an average

  14. Methodology for correlations between doses and detectability in standard mammographic images: application in Sao Paulo state

    International Nuclear Information System (INIS)

    Furquim, Tania Aparecida Correia

    2005-01-01

    Measurements using mammography units were performed in loco in 50 health establishments, randomly sampled from an equipment list of the Cadastro Nacional de Estabelecimentos de Saude (Health Establishments Brazilian Catalog). For the measurements six phantoms were utilized to establish different quality criteria and to evaluate doses in different breast thicknesses. Two different methods of measuring average glandular doses (AGD) were applied, and measurements of entrance surface doses (ESD) were also realized, in order to obtain mean values to Sao Paulo State. A study relating distribution and properties of different mammography trademarks with doses was performed. The sensitometry of processors allowed a quantification of the film-processing contrast index, A g , establishing a state mean value. The phantom images allowed the evaluation of detection limits of structures as microcalcifications, fibers, and masses, and state mean values were established for: spatial resolution (on surface and glandular breast position); image contrast; and detection expert ability from phantom images in two situations: before knowing the image targets and after viewing of a target map. Then, the results were compared to target detections in laboratory environment. Based on dose results, A g , image contrast, maximum contrast, and detection ratio, a relationship between them was determined. The results show that, in Sao Paulo State, mean glandular doses were lower than reference levels considering the Wu method, and close to or above reference levels for ail phantoms considering the Dance method. The ESD was always close to or above reference levels. The A g presented a mean value of (10,42 ± 0,20) for Sao Paulo State, and the image contrast was lower than the required limits established by the phantom manufacturers. The high contrast resolution showed that mammography units presented the expected values of line pair per mm in the State. The detectability evaluation of local

  15. Estudo da circulação retrobulbar e do campo visual após dose única oral de citrato de sildenafil (Viagra® The effects of a single dose of sildenafil citrate (Viagra® on the retrobulbar circulation and visual field

    Directory of Open Access Journals (Sweden)

    Alessandra Kurahashi

    2001-08-01

    Full Text Available Objetivo: Estudar os efeitos na circulação retrobulbar e no campo visual de uma dose oral única de 100 mg de citrato de sildenafil (Viagra®. Métodos: Um estudo duplo-mascarado e controlado por placebo foi realizado em 10 voluntários do sexo masculino, com idade média de 27,7 + 5,68 anos. O olho direito de cada voluntário foi submetido aos exames de Doppler colorido de órbita e análise de campo visual por meio de perimetria computadorizada (Humphrey, programa 30-2, estratégia "Full Threshold" em 3 ocasiões: "baseline", 1 hora após placebo e 1 hora após 100 mg de sildenafil via oral. No campo visual, analisaram-se o limiar foveal e o "mean deviation" (MD nas 3 ocasiões. No Doppler colorido, medimos a velocidade sistólica máxima (VSM, a velocidade diastólica final (VDF e o índice de resistência (IR da artéria central da retina (ACR e da artéria oftálmica (AO nas 3 ocasiões. Resultados: A administração do sildenafil não alterou significativamente o limiar foveal e o "mean deviation" em relação ao "baseline" e ao placebo. Houve um aumento significativo da velocidade sistólica máxima e velocidade diastólica final na artéria oftálmica após a administração do citrato de sildenafil (pPurpose: To analyze the effects of 100 mg of sildenafil citrate (Viagra® on the retrobulbar circulation and visual field. Methods: A double masked, placebo controlled study was conducted in 10 males with a mean age of 27.7 + 5.68 years. The right eye of each volunteer underwent orbital color Doppler imaging and automated perimetry (Humphrey, program 30-2, Full-Threshold Strategy at 3 occasions: baseline, 1 hour after placebo and 1 hour after 100 mg of sildenafil. The foveal threshold and the mean deviation (MD were analyzed by automated perimetry on the three occasions. Color Doppler imaging allowed the measurement of the peak systolic velocity (PSV, end diastolic velocity (EDV and Pourcelot index (PI in the central retinal artery and

  16. Normalization of lymphocyte count after high ablative dose of I-131 in a patient with chronic lymphoid leukemia and secondary papillary carcinoma of the thyroid: case report; Normalizacao da contagem de linfocitos apos dose ablativa de I-131 em um paciente com leucemia linfoide cronica e carcinoma papilifero da tireoide: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Thom, Anneliese Rosmarie Gertrud Fischer; Hamerschlak, Nelson; Osawa, Akemi; Santos, Fabio Pires de Souza; Pasqualin, Denise da Cunha; Wagner, Jairo; Yamaga, Lilian Yuri Itaya; Cunha, Marcelo Livorsi da; Campos Neto, Guilherme de Carvalho; Funari, Marcelo Buarque de Gusmao, E-mail: afthom@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Teles, Veronica Goes [Sociedade Brasileira de Diabetes, Sao Paulo, SP (Brazil)

    2014-07-01

    The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and paraaortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells. (author)

  17. Breast compression and radiation dose in two different mammographic oblique projections: 45 and 60 deg

    International Nuclear Information System (INIS)

    Brnic, Zoran; Hebrang, Andrija

    2001-01-01

    Introduction: Standard mammography includes two views, craniocaudal and medio-lateral oblique. Depending on patient's body constitution, central beam angle in mediolateral oblique projection may vary, with 45 deg. being suitable for the majority of patients in routine daily practice. With continuous improvement in X-ray technology and radiographers' training, the risk of radiation induced cancerogenesis is considerably reduced and acceptable when compared to benefit. However, the risk still exists, being cumulative and directly related to absorbed glandular dose. There is no minimal dose of radiation which is absolutely harmless, and every effort to reduce the dose is welcome. In this retrospective study two different angles (45 vs. 60 deg.) of mediolateral oblique view were compared according to radiation dose and efficacy of breast compression. Patients and methods: In 52 women, additional 60 deg. oblique films were done after craniocaudal and mediolateral oblique 45 deg.-films, with the same kVp and positioning technique. Breast thickness, time-current products (mA s) and absorbed doses were compared between 45 deg. - and 60 deg.-films. Subgroups of women with large, small, prominent and pendulous breasts were analyzed separately, following the same methodology as for the whole group. Results: mA s were 11.5% lower and compression 7% better with an angle of 60 deg. than with 45 deg. In the subgroup of women with small breasts, mA s values were 13% lower and compression 9% better with 60 deg. than with 45 deg., while in the subgroup with large breasts, mA s were 9% lower and compression 5% better. In the subgroup of patients with pendulous breasts, mA s values were 12% lower and compression 10% better with 60 deg. than with 45 deg., while in the subgroup with prominent breasts, mA s values were 4% lower and compression 3% better. Absorbed glandular dose was estimated to be approximately 20% lower when an oblique mammogram was done with 60 deg. instead of 45 deg

  18. Efeitos hemodinâmicos e renais da injeção de doses elevadas de clonidina no espaço peridural do cão Efectos hemodinámicos y renales de la inyección de dosis elevadas de clonidina en el espacio peridural del perro Hemodynamic and renal effects of high epidural clonidine doses in dogs

    Directory of Open Access Journals (Sweden)

    Nilson Camargo Roso

    2005-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10, que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10, que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC: bat.min-1; pressão arterial média (PAM: mmHg; pressão da artéria pulmonar ocluida (PAOP: mmHg; débito cardíaco (DC: L.min-1; volume sistólico (VS: mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR: mL.min-1; resistência vascular renal (RVR: mmHg.mL-1.min; volume urinário minuto (VUM: mL.min-1; depuração de creatinina (D Cr: mL.min-1; depuração de para-aminohipurato (D PAH: mL.min-1; fração de filtração (FF; depuração de sódio (D Na: mL.min-1; depuração de potássio (D K: mL.min-1; excreção fracionária de sódio (EF Na: %; excreção urinária de sódio (U NaV: µEq.min-1; excreção urinária de potássio (U K V: µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do d

  19. Antibodies against Escherichia coli O24 and O56 O-Specific Polysaccharides Recognize Epitopes in Human Glandular Epithelium and Nervous Tissue

    Science.gov (United States)

    Korzeniowska-Kowal, Agnieszka; Kochman, Agata; Gamian, Elżbieta; Lis-Nawara, Anna; Lipiński, Tomasz; Seweryn, Ewa; Ziółkowski, Piotr; Gamian, Andrzej

    2015-01-01

    Lipopolysaccharide (LPS), the major component of the outer membrane of Gram-negative bacteria, contains the O-polysaccharide, which is important to classify bacteria into different O-serological types within species. The O-polysaccharides of serotypes O24 and O56 of E. coli contain sialic acid in their structures, already established in our previous studies. Here, we report the isolation of specific antibodies with affinity chromatography using immobilized lipopolysaccharides. Next, we evaluated the reactivity of anti-O24 and anti-O56 antibody on human tissues histologically. The study was conducted under the assumption that the sialic acid based molecular identity of bacterial and tissue structures provides not only an understanding of the mimicry-based bacterial pathogenicity. Cross-reacting antibodies could be used to recognize specific human tissues depending on their histogenesis and differentiation, which might be useful for diagnostic purposes. The results indicate that various human tissues are recognized by anti-O24 and anti-O56 antibodies. Interestingly, only a single specific reactivity could be found in the anti-O56 antibody preparation. Several tissues studied were not reactive with either antibody, thus proving that the presence of cross-reactive antigens was tissue specific. In general, O56 antibody performed better than O24 in staining epithelial and nervous tissues. Positive staining was observed for both normal (ganglia) and tumor tissue (ganglioneuroma). Epithelial tissue showed positive staining, but an epitope recognized by O56 antibody should be considered as a marker of glandular epithelium. The reason is that malignant glandular tumor and its metastasis are stained, and also epithelium of renal tubules and glandular structures of the thyroid gland are stained. Stratified epithelium such as that of skin is definitely not stained. Therefore, the most relevant observation is that the epitope recognized by anti-O56 antibodies is a new marker

  20. Effect of a booster-dose of rabies vaccine on the duration of virus neutralizing antibody titers in bovines Efeito de uma dose de reforço da vacina anti-rábica sobre a duração de títulos de anticorpos neutralizantes do vírus, em bovinos

    Directory of Open Access Journals (Sweden)

    Avelino Albas

    1998-08-01

    Full Text Available Humoral immune response using inactivated rabies vaccine was studied in 35 nelore cross-bred bovines of western region of São Paulo state. Ninety days after vaccination, 13 (92.8% animals presented titers 30.5IU/ml, through mouse neutralization test. After 180 days, 9 (64.3% sera showed titers 30.5IU/ml, after 270 days, only one (7.1% showed a titer of 0.51IU/ml, and after 360 days, all animals showed titers 0.5IU/ml. At 180 days, 17 (80.9% sera presented titers > 0.5IU/ml; at 270 days, 15 (71.4%, with titers 30.5IU/ml and at 360 days, 4 (19.0%, with titers 30.5IU/ml. Booster-dose ensured high levels of neutralizing antibodies for at least three months, and 240 days after revaccination, 71.4% of animals were found with titers 30.5IU/ml.A resposta humoral com vacina anti-rábica inativada foi estudada em 35 bovinos mestiços de raça nelore, na região oeste do estado de São Paulo. Noventa dias após a primo-vacinação, 13 (92,8% animais apresentaram títulos 30,5UI/ml, através da prova de soroneutralização em camundongos. Após 180 dias, 9 (64,3% soros evidenciaram títulos 30,5UI/ml; após 270 dias, apenas 1 (7,1% soro demonstrou título = 0,51 UI/ml. O grupo que recebeu dose de reforço 30 dias após primo-vacinação apresentou, dois meses depois, 21 animais com títulos > 0,5UI/ml. Aos 180 dias, 17 (80,9% soros apresentaram títulos > 0,5UI/ml; aos 270 dias, 15 (71,4% soros com títulos 30,5UI/ml; aos 360 dias, 4 (19,0% com títulos 30,5UI/ml. O reforço proporcionou nível elevado de anticorpos, por um período de três meses ou mais e, 240 dias após a revacinação, 71,4% dos animais apresentou títulos 30,5UI/ml.

  1. Terapia com inibidor da ECA com dosagens relativamente altas e risco de agravamento renal na insuficiência cardíaca crônica ACE-inhibitor therapy at relatively high doses and risk of renal worsening in chronic heart failure

    Directory of Open Access Journals (Sweden)

    Renato De Vecchis

    2011-12-01

    Full Text Available FUNDAMENTO: O efeito renoprotetor dos inibidores da ECA vem sendo questionado no caso de diminuição do volume circulante efetivo, como na insuficiência cardíaca crônica direita ou biventricular. Objetivo: Detectar os preditores clínicos de agravamento renal na população de pacientes com ICC, caracterizado por dois tipos de regime de dosagem de inibidores da ECA. MÉTODOS: De acordo com um desenho de coorte retrospectiva, seguimos dois grupos de pacientes com ICC - tanto direita quanto biventricular -, todos na classe III da NYHA, tratados com inibidores da ECA (enalapril ou lisinopril, e com fração de ejeção do ventrículo esquerdo (FEVE 10 mg por dia de enalapril ou lisinopril. A disfunção renal agravada (ARD foi definida pelo aumento de Cr > 30% com relação ao segmento basal. O modelo de risco proporcional de Cox foi utilizado para identificar os preditores da ARD entre as seguintes variáveis: os inibidores da ECA com "alta" dosagem, idade, FEVE basal, histórico de repetidas terapias intensivas com diuréticos de alça por via intravenosa (diurético intravenoso, diabete, Cr basal, histórico de hipertensão, pressão arterial sistólica BACKGROUND: Renoprotective effect of ACE-inhibitors has been questioned in case of decreased effective circulating volume, like in right or biventricular chronic heart failure. OBJECTIVE: To detect clinical predictors of renal worsening in CHF patient population characterized by two types of ACE-inhibitor dosing regimens. METHODS: According to a retrospective cohort design, we followed 2 groups of patients with CHF - whether right or biventricular -, all in III NYHA class treated with ACE-inhibitors (enalapril or lisinopril, and with left ventricular ejection fraction (LVEF 10 mg per day of enalapril or lisinopril. Worsened renal failure (ARD was defined by Cr increase >30% from baseline. Cox proportional hazards model was used to identify the predictors of ARD among the following variables

  2. Radiation doses and some aspects of image quality in mammography facilities in New Zealand

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; Poletti, J.L.

    1990-02-01

    Until recently, mammography in New Zealand was performed largely with adapted conventional x-ray machines with tungsten anode x-ray tubes. Over the last several years these have virtually all been replaced by dedicated mammography machines with molybdenum anode x-ray tubes. To assess current trends in radiation doses to patients and central aspects of image quality, some 37 mammography x-ray machines were surveyed during 1988-89. The mean glandular dose per film for 30 and 45 mm thick breast-equivalent phantoms was determined using thermoluminescent dosimetry. Imagings of simulated microcalcifications (specks) and a contrast-detail phantom were assessed. Accuracy of calibration of the x-ray machines and quality of film processing were also tested. Details of the survey results are given. Mean glandular tissue doses per cranio-caudal films were generally well within the recommended guidelines. Mammography facilities differed in their ability to delete simulated calcification specks. Mammographic equipment was found to be generally well adjusted. Speed and contrast of film processing were found to vary widely implying that this is a major cause of the variations in dose and image quality. An annex outlines a quality assurance programme for maintenance of optimal physical image quality and control of radiation doses. 55 refs., 21 tabs., 17 figs., 2 ills

  3. Patient Safety in Drug Therapy and the Influence of the Prescription in Dose Errors Seguridad del paciente en la terapéutica medicamentosa y la influencia de la prescripción médica en los errores de dosis Segurança do paciente na terapêutica medicamentosa e a influência da prescrição médica nos erros de dose

    Directory of Open Access Journals (Sweden)

    Fernanda Raphael Escobar Gimenes

    2010-12-01

    ineficiencia del tratamiento, comprometiendo así, la calidad de la asistencia prestada a los pacientes hospitalizados.Os objetivos foram analisar a redação da prescrição médica nos erros de doses, ocorridos em unidades de clínica médica de cinco hospitais brasileiros, e identificar as classes farmacológicas envolvidas nesses erros. Este é estudo descritivo que utilizou dados secundários, obtidos de pesquisa multicêntrica, realizada em 2005. A população foi composta por 1425 erros de medicação e a amostra por 215 erros de doses. Desses, 44,2% ocorreram no hospital E. Verificou-se presença de siglas e/ou abreviaturas em 96,3% das prescrições, ausência do registro do paciente em 54,4%, falta de posologia em 18,1% e omissão da data em 0,9%. Com relação ao tipo de medicamento, 16,8% eram broncodilatadores, 16,3% eram analgésicos, 12,1%, anti-hipertensivos e 8,4% eram antimicrobianos. A ausência da posologia nas prescrições pode favorecer a administração de doses erradas, resultando em ineficiência do tratamento, comprometendo a qualidade da assistência prestada aos pacientes hospitalizados.

  4. Trend of patient radiation doses in medical examination in Japan

    International Nuclear Information System (INIS)

    Suzuki, Shoichi

    2013-01-01

    We have investigated radiation doses to patients in selected types of examinations in Japan since 1974 and have analyzed the trend of patient radiation doses during a period of 37 years. This study covered regular plain X-ray scanning (including mammography) and computed tomography (CT) scanning. Dose evaluation was performed in terms of entrance skin dose (ESD) for regular plain X-ray scanning, average glandular dose (AGD) for mammography, and volume CT dose index (CTDIvol) for CT scanning. Evaluation was performed in 26 orientations at 21 sites for regular plain X-rays, and for cranial, thoracic, and abdominal scans of children and adults for CT scanning. With the exception of chest X-rays, the dose during regular plain X-ray scanning had decreased by approximately 50% compared with scans performed in 1974. The dose during mammography had decreased to less than 10% of its former level. In scans performed in 2011, dose at all sites were within International Atomic Energy Authority (IAEA) guidance levels. The increasing use of multiple detectors in CT scanning devices was evident in CT scanning. A comparison of doses from cranial non-helical scans performed in 2007 and 2011 found that the latter were higher. An examination of changes in doses between 1997 and 2011 revealed that doses had tended to increase in cranial scans of adults, but had hardly changed at all in abdominal scans. Doses during CT scanning of children were around half those for adults in cranial, thoracic, and abdominal scans. We have ascertained changes in the doses to which patients have been exposed during X-ray scanning in Japan. (author)

  5. Inalador dosimetrado com espaçador artesanal versus nebulizador no tratamento da crise de sibilância na criança Metered-dose inhaler with home-made spacer versus nebulizers to treat moderate wheezing attacks in children

    Directory of Open Access Journals (Sweden)

    Liana Consuelo Santana Vilarinho

    2003-10-01

    Full Text Available OBJETIVO: Realizou-se um ensaio clínico objetivando comparar duas modalidades de administração de salbutamol na crise de sibilância em crianças - através de nebulizador de jato e através de inalador dosimetrado acoplado a um espaçador artesanal. MATERIAL E MÉTODOS: Foi estudada uma amostra de conveniência de crianças em crise moderada de sibilância, alocadas aleatoriamente em dois grupos de tratamento, de acordo com o dispositivo inalatório utilizado para a administração de salbutamol (nebulizador - grupo NEB, ou inalador dosimetrado com espaçador - grupo IDE. Os parâmetros utilizados para comparação entre os grupos foram agrupados em tabela de pontos e consistiram em sinais clínicos habitualmente usados na avaliação da gravidade da crise asmática (nível de consciência, coloração da pele, intensidade da dispnéia, intensidade da tiragem, tempo expiratório, entrada de ar e sibilância e a saturação transcutânea de oxigênio, obtidos antes do tratamento e 15 minutos após cada administração do salbutamol. Como dados adicionais, mediram-se os tempos de preparo e de uso das medicações, computaram-se os custos envolvidos nas duas formas de tratamento, e interrogaram-se os acompanhantes sobre o grau de satisfação em relação aos tratamentos. Cada criança usou salbutamol em doses repetidas a cada 20 minutos, interrompendo-se a administração quando a crise passava de moderada a leve. Quando a crise persistia moderada, após a segunda dose de salbutamol, acrescentava-se corticóide oral. A participação das crianças era concluída quando elas passavam à crise leve, ou após a terceira dose de salbutamol. A dose de salbutamol usada no grupo IDE foi 1/3 da dose usada no grupo NEB. RESULTADOS: Participaram do estudo 54 crianças com idades que variaram de 22 dias a 11,7 anos. Cada grupo abrangeu 27 crianças. Os grupos não diferiram demograficamente e em relação à pontuação clínica e aos valores de

  6. A unique case of a huge mixed squamous cell and glandular papilloma of non-endobronchial origin with a peripheral growth

    Directory of Open Access Journals (Sweden)

    Kei Yabuki

    Full Text Available We report a case of a huge solitary non-endobronchial pulmonary tumor in a 76-year-old male smoker. The tumor measured 11 × 10 × 8 cm. It was ill-defined, and it was located periphery of the right lower lobe with the subpleural cystic spaces. He underwent right lower lobectomy with mediastinal lymph node dissection and is free from tumor 30 months after surgery. Microscopically, it was composed of a proliferation of squamous and ciliated columnar epithelial cells with a few mucous cells. These cells were arranged in a papillary growth fashion extending along the fibrously thickened alveolar septa together with metaplastic bronchiolar and squamous epithelia displaying an usual interstitial pneumonia-pattern. Although the histologic features of the tumor were that of a mixed squamous cell and glandular papilloma (MSCGP, it was peripherally located and showed a lepidic growth, and it was much larger than previously reported MSCGPs. It is possible that the tumor developed in association with bronchial metaplasia in the periphery of the lung, and then extended along the surface of the reconstructed air spaces, which resulted in its unique histologic appearance. Further investigations of respiratory papilloma are needed to clarify the pathogenesis of these lesions. Keywords: Mixed squamous cell and glandular papilloma, Non-endobronchial, Cytology, Interstitial pneumonia, Pulmonary tumor

  7. Brain tissue oxidative damage as a possible mechanism for the deleterious effect of a chronic high dose of estradiol on learning and memory in ovariectomized rats Dano oxidativo ao tecido cerebral como possível mecanismo de efeito deletério da alta dose crônica de estradiol no aprendizado e memória de ratas ooforectomizadas

    Directory of Open Access Journals (Sweden)

    Fatimeh Khodabandehloo

    2013-05-01

    Full Text Available In addition to antioxidative effects, estrogens also exert pro-oxidative actions. The effect of chronic administration of a high dose of estradiol valerate on Morris water maze tasks and brain tissues oxidative damage was investigated. The Sham-Est and OVX-Est groups were treated with estradiol valerate (4 mg/kg for 12 weeks. Escape latency and traveled path in the Sham-Est and OVX-Est groups were significantly higher than in the Sham and OVX groups (p≪0.01 and p≪0.001. In the probe trial, the animals of the Sham-Est and OVX-Est groups spent lower time in Q1 compared to Sham and OVX groups (p≪0.05 and p≪0.001. In Sham-Est and OVX-Est groups, the brain tissue total thiol concentration was significantly lower, and malondialdehyde (MDA concentrations were higher than in the Sham and OVX groups (p≪0.05 and p≪0.001. It is concluded that administration of high exogenous levels of estradiol impairs performance and enhances oxidative stress.Além dos efeitos antioxidantes, os estrógenos também têm ação pró-oxidativa. Foi investigado o efeito da administração crônica de alta dose de valereato de estradiol no desempenho do labirinto aquático de Morris e o dano oxidativo ao tecido cerebral. Os grupos Sham-Est e OVX-Est foram tratados com valereato de estradiol (4 mg/kg por 12 semanas. O tempo de latência para escapada e o caminho percorrido foram significativamente maiores nos grupos Sham-Est e OVX-Est em relação aos grupos Sham e OVX (p≪0,01 e p≪0,001. No estudo probe, os animais dos grupos Sham-Est e OVX-Est levaram menos tempo no Q1 em comparação aos grupos Sham e OVX (p≪0,05 e p≪0,001. Nos grupos Sham-Est e OVX-Est, a concentração total de tiol foi significativamente menor, enquanto a concentração de malondialdehydo (MDA for maior do que aquela dos grupos Sham e OVX (p≪0,05 e p≪0,001. Concluiu-se que a administração de altas doses de estradiol exógeno compromete o desempenho e aumenta o estresse oxidativo

  8. Different doses of exogenous surfactant for treatment of meconium aspiration syndrome in newborn rabbits Estudo dos efeitos de diferentes doses de surfactante exógeno para o tratamento da síndrome de aspiração de mecônio em coelhos recém-nascidos

    Directory of Open Access Journals (Sweden)

    João Cesar Lyra

    2004-01-01

    Full Text Available OBJECTIVE: To evaluate the effects of 2 different doses of exogenous surfactant on pulmonary mechanics and on the regularity of pulmonary parenchyma inflation in newborn rabbits. METHOD: Newborn rabbits were submitted to tracheostomy and randomized into 4 study groups: the Control group did not receive any material inside the trachea; the MEC group was instilled with meconium, without surfactant treatment; the S100 and S200 groups were instilled with meconium and were treated with 100 and 200 mg/kg of exogenous surfactant (produced by Instituto Butantan respectively. Animals from the 4 groups were mechanically ventilated during a 25-minute period. Dynamic compliance, ventilatory pressure, tidal volume, and maximum lung volume (P-V curve were evaluated. Histological analysis was conducted using the mean linear intercept (Lm, and the lung tissue distortion index (SDI was derived from the standard deviation of the means of the Lm. One-way analysis of variance was used with a = 0.05. RESULTS: After 25 minutes of ventilation, dynamic compliance (mL/cm H2O · kg was 0.87 ± 0.07 (Control; 0.49 ± 0.04 (MEC*; 0.67 ± 0.06 (S100; and 0.67 ± 0.08 (S200, and ventilatory pressure (cm H2O was 9.0 ± 0.9 (Control; 16.5 ± 1.7 (MEC*; 12.4 ± 1.1 (S100; and 12.1 ± 1.5 (S200. Both treated groups had lower Lm values and more homogeneity in the lung parenchyma compared to the MEC group: SDI = 7.5 ± 1.9 (Control; 11.3 ± 2.5 (MEC*, 5.8 ± 1.9 (S100; and 6.7 ± 1.7 (S200 (*P OBJETIVO: Avaliar os efeitos de duas diferentes doses de surfactante exógeno sobre a mecânica pulmonar e sobre a regularidade da expansão do parênquima pulmonar em coelhos recém-nascidos. MÉTODO: Coelhos recém-nascidos foram traqueostomizados e randomizados em quatro grupos de estudo: grupo-Controle, sem aspiração de mecônio; grupo MEC, com aspiração de mecônio e sem tratamento com surfactante exógeno; grupos S100 e S200, ambos com aspiração de mecônio e tratados

  9. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  10. Dose absorbed in adults and children thyroid due to the I{sup 123} using the dosimetry MIRD and Marinelli; Dosis absorbida en tiroides de adultos y ninos debido al I{sup 123} utilizando las dosimetrias MIRD y Marinelli

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.; Castillo, C.; Cabrera, C.; Sarachaga, R.; Castaneda, J. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Ciudad Universitaria, Trujillo (Peru); Diaz, E., E-mail: marvva@hotmail.com [Universidade Federal do Rio Grande do Sul, Av. Paulo Gamma 110, Bairro Farropilhas, Porto Alegre, RS 90040-060 (Brazil)

    2014-08-15

    Using the dosimetry MIRD, and representation Cristy-Eckerman in the thyroid gland and organs of their bio-kinetics when I{sup 123} (Iodine) is used, the study demonstrates that the absorbed dose by the gland of an adult, children, and newly born, is their auto-dose, independent of the compartments number of their bio-kinetics. The dosimetric contributions of the organs of their bio-kinetics are insignificant. Their results are not significantly different to those obtained by the formalism MARINELLI (auto-dose) when it uses a sphere like glandular representation. In consequence, the kinetic model corresponding to the glandular representation decreases to a compartment, where the gland can also be represented like a sphere. (Author)

  11. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R [Durham, NC (United States); Lakshmanan, M; Fong, G; Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States); Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to

  12. Image Quality and Radiation Dose Assessment of a Digital Mammography System

    International Nuclear Information System (INIS)

    Isa, N. M.; Hassan, W. M. S. W.; Abdullah, W. A. K. W.; Othman, F.; Ramli, A. A. M.

    2010-01-01

    Image quality and radiation dose of a direct amorphous selenium digital mammography system were considered in terms of contrast to noise ratio (CNR) and average glandular dose (AGD). They were measured for various qualities and breast phantom thicknesses with different types of breast tissue composition to determine optimal radiation quality and dose. Three sets of breast tissue equivalent slabs (30%:70%, 50%:50% and 70%:30% glandular-adipose) with thickness of 2 cm to 7 cm and 0.2 mm aluminum foil were used to provide certain CNR. Two different combinations of anode/ilter material and a wide range of tube voltages were employed for each phantom thickness. Phantom images with grid were acquired using automatic exposure control (AEC) mode for each thickness. Phantom images without grid were also obtained in manual exposure mode by selecting the same anode/filter combination and kVp as the image obtained with grid at the same thickness, but varying mAs of 10 to 200 mAs. Optimization indicated that relatively high energy beam qualities should be used with a greater dose to compensate for lower energy x-rays. The results also indicate that current AEC setting for a fixed detector is not optimal.

  13. Desfechos clínicos do tratamento de tuberculose utilizando o esquema básico recomendado pelo Ministério da Saúde do Brasil com comprimidos em dose fixa combinada na região metropolitana de Goiânia Clinical treatment outcomes of tuberculosis treated with the basic regimen recommended by the Brazilian National Ministry of Health using fixed-dose combination tablets in the greater metropolitan area of Goiânia, Brazil

    Directory of Open Access Journals (Sweden)

    Anna Carolina Galvão Ferreira

    2013-02-01

    Full Text Available OBJETIVO: Descrever as taxas de cura, falência e abandono do tratamento da tuberculose com o esquema básico preconizado pelo Ministério da Saúde (tratamento com rifampicina, isoniazida, pirazinamida e etambutol por dois meses seguido de isoniazida e rifampicina por quatro meses utilizando comprimidos em dose fixa combinada em regime autoadministrado e descrever os eventos adversos e seus possíveis impactos nos desfechos do tratamento. MÉTODOS: Estudo descritivo utilizando dados coletados prospectivamente dos prontuários médicos de pacientes com tuberculose (idade > 18 anos tratados com o esquema básico em duas unidades básicas de saúde da região metropolitana de Goiânia, GO. RESULTADOS: A amostra foi composta por 40 pacientes com tuberculose. A taxa de cura foi de 67,5%, a taxa de abandono foi de 17,5%, e não ocorreram casos de falência. Nessa amostra, 19 pacientes (47% relataram reações adversas aos medicamentos. Essas foram leves e moderadas, respectivamente, em 87% e 13% dos casos. Em nenhum caso houve necessidade de mudança do esquema ou suspensão do tratamento. CONCLUSÕES: A taxa de cura do esquema básico com o uso de comprimidos em dose fixa combinada sob regime autoadministrado foi semelhante às taxas históricas do esquema anterior. A taxa de abandono, na amostra estudada, foi muito acima da taxa preconizada como adequada (até 5%.OBJECTIVE: To describe the rates of cure, treatment failure, and treatment abandonment obtained with the basic regimen recommended by the Brazilian National Ministry of Health (rifampin, isoniazid, pyrazinamide, and ethambutol for two months, followed by isoniazid and rifampin for four months involving the use of fixed-dose combination tablets (self-administered treatment, as well as to describe adverse events and their potential impact on treatment outcomes. METHODS: This was a descriptive study based on prospective data obtained from the medical records of tuberculosis patients (> 18

  14. Weldon Spring dose calculations

    International Nuclear Information System (INIS)

    Dickson, H.W.; Hill, G.S.; Perdue, P.T.

    1978-09-01

    In response to a request by the Oak Ridge Operations (ORO) Office of the Department of Energy (DOE) for assistance to the Department of the Army (DA) on the decommissioning of the Weldon Spring Chemical Plant, the Health and Safety Research Division of the Oak Ridge National Laboratory (ORNL) performed limited dose assessment calculations for that site. Based upon radiological measurements from a number of soil samples analyzed by ORNL and from previously acquired radiological data for the Weldon Spring site, source terms were derived to calculate radiation doses for three specific site scenarios. These three hypothetical scenarios are: a wildlife refuge for hunting, fishing, and general outdoor recreation; a school with 40 hr per week occupancy by students and a custodian; and a truck farm producing fruits, vegetables, meat, and dairy products which may be consumed on site. Radiation doses are reported for each of these scenarios both for measured uranium daughter equilibrium ratios and for assumed secular equilibrium. Doses are lower for the nonequilibrium case

  15. Fixação biológica de nitrogênio e aspectos agronômicos da soja (Glycine max (L. Merr. sob diferentes doses de inoculante

    Directory of Open Access Journals (Sweden)

    Alessandro Pedrozo

    2018-04-01

    Full Text Available A soja é uma das oleaginosas mais importantes no mundo e possui grande versatilidade. O objetivo deste estudo foi estudar o efeito da inoculação de 600 e 1200 mL ha–1 de um inoculante líquido com Bradyrhizobium japonicum e com ou sem adição de 1 L de cálcio ha–1 (Ca 41% e de 0,4 L de boro ha–1 (B 14% na cultura da soja. As plantas foram crescidas por 90 dias em potes plásticos com 3 kg de areia: vermiculita (v:v autoclavados (121ºC, 1 h. O experimento foi conduzido em delineamento inteiramente casualizado, com 5 repetições em casa de vegetação. Foram determinados parâmetros relacionados com o desenvolvimento e produtividade da soja, como: a massa seca da parte aérea, de raízes e total, nitrogênio da parte aérea, número e massa seca de nódulos, índice de clorofila das folhas, número de vagens por planta (NVPL, número de grãos por vagens (NGV e número de grãos por planta (NGPL. A adição de Ca+B aumentou significantemente NVPL, NGPL e NGV. O NVPL, NGPL foram aumentados significantemente com a adição de 600 mL ha–1 inoculante. A adição de 600 mL ha–1 inoculante juntamente com a adição de Ca+B estimulou significativamente o NVPL, NGPL e NGV. Conclui- se que a produtividade da cultura da soja foi aumentada com a adição de 600 mL ha–1 inoculante juntamente com a adição de Ca e B.

  16. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  17. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A. [Federal University of Minas Gerais, Program of Nuclear Science and Techniques, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  18. Radiation doses in mammography as planning parameters for premature breast cancer tracking programs

    International Nuclear Information System (INIS)

    Souza Ferreira, Rubemar de.

    1994-01-01

    Radiation doses are the main parameters applied to the evaluation of mammographic radiological impact. This study, for a sample of 407 women, were analyzed, through the thermoluminescent dosimetry, radiation doses in the surface of skin and glandular absorbed doses for cranio-caudal view. The results show the presence of a large dose range to the same mammographic procedure, which, analyzed enclosed with 585 facilities, suggest be necessary the standardization of the mammographic technique. From that results, with the additive model, the excess of breast cancer (radioinduced) and lifetime loss risk, for age groups between 30 and 70 years were estimated. Is demonstrated that the benefits from dedicated mammography, overcome the relationship among the epidemiological aspects of breast cancer and ionizing radiation as an harmful agent, which may show an important correlation for large exposed populations, point out the importance of the continuous risk and benefit evaluation to the new technologies introduced. (author). 86 refs., 40 figs., 14 tabs

  19. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    International Nuclear Information System (INIS)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A.

    2015-10-01

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  20. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  1. Distinct Ezrin Truncations Differentiate Metastases in Sentinel Lymph Nodes from Unaffected Lymph Node Tissues, from Primary Breast Tumors, and from Healthy Glandular Breast Tissues

    Directory of Open Access Journals (Sweden)

    Claudia Röwer

    2018-02-01

    Full Text Available BACKGROUND: Lymph node metastasis status is a prognostic factor for further lymph node involvement and for patient survival in breast cancer patients. Frozen section analysis of lymph nodes is a reliable method for detection of macro-metastases. However, this method is far less effective in detecting micro-metastases, requesting improved diagnostic procedures. METHODS: We investigated expression and truncation of ezrin in (i sentinel lymph node metastases, (ii unaffected axillary lymph nodes, (iii primary breast tumors, and (iv healthy glandular breast tissues using 2D gel electrophoresis, SDS-PAGE, and mass spectrometry in addition to Western blotting. RESULTS: Full-length ezrin (E1; amino acids 1–586 is present in all four investigated tissues. Two truncated ezrin forms, one missing about the first hundred amino acids (E2a and the other lacking about 150 C-terminal amino acids (E2b were detectable in primary tumor tissues and in sentinel lymph node metastases but not in glandular tissues. Strikingly, an ezrin truncation (E3 which consists approximately of amino acids 238–586 was found strongly expressed in all sentinel lymph node metastases. Moreover, an N-terminal ezrin fragment (E4 that consists approximately of amino acids 1–273 was identified in sentinel lymph node metastases as well. CONCLUSIONS: We show for the first time the existence of tissue-dependent specific ezrin truncations. The distinguished strong Western blot staining of ezrin E3 in sentinel lymph node metastases underlines its capability to substantiate the occurrence of lymph node (micrometastases in breast cancer patients.

  2. Usefulness of p16ink4a, ProEX C, and Ki-67 for the diagnosis of glandular dysplasia and adenocarcinoma of the cervix uteri.

    Science.gov (United States)

    Negri, Giovanni; Bellisano, Giulia; Carico, Elisabetta; Faa, Gavino; Kasal, Armin; Antoniazzi, Sonia; Egarter-Vigl, Eduard; Piccin, Andrea; Dalla Palma, Paolo; Vittadello, Fabio

    2011-07-01

    Although the diagnostic criteria of in-situ and invasive adenocarcinomas of the cervix uteri are well established, the differentiation from benign mimics may be difficult and the morphologic features of the precursors of endocervical adenocarcinoma are still debated. In this study, we evaluated the usefulness of p16ink4a (p16), ProEX C, and Ki-67 for the diagnosis of endocervical adenocarcinoma and its precursors. Immunohistochemistry with p16, ProEX C, and Ki-67 was performed in 82 glandular lesions including 15 invasive adenocarcinomas, 29 adenocarcinomas in situ (AIS), 22 non-neoplastic samples, and 16 cases of glandular dysplasia (GD), which showed significant nuclear abnormalities but did not meet the diagnostic criteria for AIS. The immunohistochemical expression pattern was scored according to the percentage of the stained cells (0, 1+, 2+, and 3+ when 0% to 5%, 6% to 25%, 26% to 50%, and more than 50% of the cells were stained, respectively) and was evaluated for each antibody. p16 was at least focally expressed (1+ or more) in 14 of 15 invasive adenocarcinomas, in all AIS and in 7 negative samples. ProEX C and Ki-67 both scored 1+ or more in all adenocarcinomas and AIS and in 8 and 6 negative samples, respectively. Of the GD 15, 14, and 15 expressed p16, ProEX C, and Ki-67, respectively. The score differences between neoplastic and non-neoplastic samples were highly significant for each marker (Pcervix uteri and may also improve the diagnostic accuracy of endocervical GD. In particularly problematic cases, the combination of p16 and a proliferation marker can provide additional help for the interpretation of these lesions.

  3. Plasminogen-independent initiation of the pro-urokinase activation cascade in vivo. Activation of pro-urokinase by glandular kallikrein (mGK-6) in plasminogen-deficient mice

    DEFF Research Database (Denmark)

    List, K; Jensen, Ole Nørregaard; Bugge, T H

    2000-01-01

    )-antitrypsin. We suggest that mouse glandular kallikrein mGK-6 is an activator of pro-uPA in the mouse urinary tract in vivo. Since this kallikrein is expressed in a number of tissues and also occurs in plasma, it can also be considered a candidate for a physiological pro-uPA activator in other locations....

  4. Determination of photon contamination dose of clinical electron beams using the generalized simulated annealing method; Determinação da dose dos fótons contaminantes de feixes de elétrons clínicos usando o Método de Recozimento Simulado Generalizado

    Energy Technology Data Exchange (ETDEWEB)

    Visbal, Jorge H. Wilches; Costa, Alessandro M. da, E-mail: jhwilchev@gmail.com [Universidade de Sao Paulo (USP), Ribeirão Preto, SP (Brazil). Faculdade de Filosofia, Ciências e Letras

    2017-07-01

    Clinical electron beams are composed of a mixture of pure electrons and Bremsstrahlung photons produced in the structures of the accelerator head as well as in the air. Accurate knowledge of these components is important for calculating the dose and for treatment planning. There are at least two approaches to deter-mine the contribution of the photons in the percentage depth dose of clinical electrons: a) Analytical Method that calculates the dose of the photons from the previous determination of the spectrum of the incident Bremsstrahlung photons; b) Adjustment method based on a semi-empirical biexponential formula where four parameters must be established from optimization methods. The results show that the generalized simulated annealing method can calculate the photon contamination dose by overestimating the dose in the tail no more than 0.6% of the maximum dose (electrons and photons). (author)

  5. Produção e composição mineral da beterraba sob doses de sódio e potássio, em solução nutritiva

    OpenAIRE

    Carvalho, Karina Fernandes

    2014-01-01

    Altas concentrações de sódio podem diminuir o rendimento de diversas culturas. Entretanto o sódio é um elemento benéfico à beterraba, podendo substituir as funções do potássio. Estudos mostraram que o sódio é responsável pelo aumento da produção de beterraba açucareira e hortícola. O presente trabalho objetivou verificar a resposta da nutrição com sódio em substituição e em adição à nutrição potássica sobre o crescimento, produção, composição mineral e a relação do sódio com os macronutriente...

  6. Investigation of absorbed radiation dose in refraction-enhanced breast tomosynthesis by a Laue case analyser

    International Nuclear Information System (INIS)

    Sato, H.; Ando, M.; Shimao, D.

    2011-01-01

    An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50 deg., in increments of 1 deg., by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. (authors)

  7. Determination of dose levels for chest (PA), lumbar spine (AP and LAT) and mammography (CC and MLO) for Latin america

    International Nuclear Information System (INIS)

    Mora, P.; Ramirez, R.; Blanco, D. E.; Benavente, T. A.; Ortiz Lopez, P.; Giannone, C. A.; Gherco, J. T.; Mecca, F.; Kodlulovich, S.; Ramirez, A.; Anselmo Puerta, J. A.; Fonseca, L.; Cardenas, J.; Martinez, A.; Zorin, F. J.; Roas, N.; Garcia, F.; Caldeira, M. E.; Salazar, G.

    2006-01-01

    Under the auspices of the ARCAL Technical Cooperation Program of the IAEA, 11 countries in Latin American (Argentina, Brazil, Chile, Costa Rica, Cuba, Mexico, Nicaragua, Peru, Uruguay and Venezuela) motivated by the necessity to optimize the doses in diagnostic procedures, started the first regional pilot study to determine the guidance dose levels for chest (PA), lumbar spine (AP and LAT) and mammography (CC and MLO) procedures. A total of 33 hospitals participated with 54 diagnostic X-ray equipment and 18 mammography units. The entrance kerma and mean glandular doses were obtained through the output of the X-rays. A TLD intercomparison was carried out as a means to do quality control of all the process. A total of 2120 doses were estimated with the information of each patient (kVp, mAs, distance, etc.). Parallel to this, the image quality of the studies was evaluated using the criteria established by the European Community. The values of the entrance kerma an mean glandular doses for the 75% percentile are in general very compatible with the ones in Schedule III of the NBS. Although this study did not allow the establishment of guidance levels for the region, it did lay the foundations for optimization processes and the necessity of making better efforts that will improve medical practices. (Author)

  8. Crescimento, desenvolvimento e retardamento da senescência foliar em girassol de vaso (Helianthus annuus L.: fontes e doses de nitrogênio Growth, development and delay of leaf senescence in pot-grown sunflower (Helianthus annuus L.: sources and rates of nitrogen

    Directory of Open Access Journals (Sweden)

    Joelma Dutra Fagundes

    2007-08-01

    Full Text Available O girassol é a quarta oleaginosa em produção de grãos no mundo e alguns genótipos são usados com finalidade ornamental para flor de corte e de vaso (girassol de vaso. O objetivo do trabalho foi avaliar o efeito de diferentes fontes e doses de nitrogênio sobre alguns parâmetros de crescimento, desenvolvimento e no retardamento da senescência das folhas basais em girassol de vaso. Um experimento foi conduzido em casa de vegetação, em Santa Maria, RS. Os tratamentos foram: uréia, nitrato de amônio e nitrato de cálcio nas doses de 0, 50, 100 e 150mg L-1 de N na solução de fertirrigação, com duas aplicações semanais. O experimento foi um bi-fatorial (fontes e doses de N no delineamento inteiramente casualizado, com seis repetições. Cada repetição foi um vaso no 15 (1,3L, 15cm de altura com uma planta por vaso. As variáveis analisadas foram: número final de folhas, altura final de plantas, porcentagem de folhas senescentes no ponto de venda, porcentagem de folhas senescentes no final de vida de vaso, área foliar total da planta, filocrono e a soma térmica acumulada da emergência ao botão visível e da emergência ao ponto de venda. A fonte de N tem influência sobre a área foliar do girassol de vaso, sendo a uréia recomendável para o maior crescimento das folhas. A dose de N em torno de 100mg L-1 aplicada duas vezes por semana via fertirrigação favorece características desejáveis para a comercialização, como precocidade e retardamento da senescência das folhas.Sunflower is the fourth oil grain crop grown worldwide and some genotypes are used with ornamental purpose as cut and pot-grown flower. The objective of this study was to evaluate the effect of different sources and rates of nitrogen on some growth and developmental parameters, and on the delay of leaf senescence in pot-grown sunflower. An experiment was carried out inside a greenhouse in Santa Maria, RS, Brazil. Treatments were: urea, ammonium nitrate and

  9. Investigation on 3D dose distribution in digital breast tomosynthesis

    Science.gov (United States)

    Masi, M.

    2017-03-01

    Monte Carlo calculations for dosimetry in digital breast tomosynthesis (DBT) require experimental validations. We measured the 3D dose distribution in a breast phantom in a DBT scan, using XR-QA2 radiochromic films. We positioned film pieces at the entrance surface, at the bottom surface and at four depths between adjacent slabs in the 5-slabs, 5-cm-thick phantom simulating a compressed breast with 50% glandular fraction. We irradiated the phantom at 40kV (half value layer 1.1mm Al) for three angular tilting of the beam central axis ( {±}25° and 0° normal incidence). We determined the transverse and longitudinal distributions of the average dose in the phantom (in terms of air kerma normalized to the entrance air kerma), showing the angular dependence of the depth-resolved 3D dose distributions. In transverse planes the maximum dose variations were between 5.0% and 14.8% for normal incidence, and by 8.6% from the central to the tilted view. In the direction of the beam axis, the dose decreases up to about 71% from the entrance to the exit value. The extimated backscatter fraction was between 3% and 8%.

  10. Dose preparatória de atracúrio: aferição da fadiga no músculo orbicular do olho e condições de intubação orotraqueal Dosis preparatoria de atracurio: comparación de la fatiga en el músculo orbicular del ojo y condiciones de intubación orotraqueal Priming dose of atracurium: measuring orbicularis oculi muscle fade and tracheal intubation conditions

    Directory of Open Access Journals (Sweden)

    Giovani de Figueiredo Locks

    2003-12-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: O método da dose preparatória (priming principle consiste na injeção de uma pequena dose do bloqueador neuromuscular, minutos antes da administração do restante da dose preconizada para intubação traqueal, para encurtar o início de ação dos bloqueadores neuromusculares (BNM adespolarizantes. Existe, porém, possibilidade de fadiga muscular e broncoaspiração. De interesse especial para as manobras de intubação orotraqueal e proteção das vias aéreas, são os músculos da laringe. Como sua monitorização direta impõe dificuldades técnicas, foi demonstrado que o músculo orbicular do olho apresenta correlação com os músculos laríngeos quanto à sensibilidade aos BNM. O objetivo desta pesquisa é avaliar se há fadiga do músculo orbicular ocular após o uso da dose preparatória de atracúrio e comparar as condições clínicas de intubação traqueal após dois intervalos entre as doses. MÉTODO: Foram selecionados 35 pacientes adultos, estado físico ASA I ou II, sem fatores de risco para broncoaspiração, submetidos à cirurgia eletiva. Foi induzida anestesia geral com alfentanil e propofol e os pacientes foram ventilados manualmente sob máscara. Em seguida, foram posicionados os eletrodos para estimular o ramo temporal do nervo facial e o transdutor de aceleração no músculo orbicular do olho. Administrou-se a dose preparatória de atracúrio (0,02 mg.kg-1 e a relação T4/T1 foi avaliada a cada minuto durante 5 minutos em 20 casos (G1 e 7 minutos em 13 casos (G2. Após este intervalo, administrou-se a dose complementar de atracúrio (0,5 mg.kg-1 e procedeu-se a intubação orotraqueal após um minuto. Foi considerada fadiga clinicamente importante a relação T4/T1 inferior a 0,9. RESULTADOS: Nenhum paciente apresentou fadiga durante o intervalo de monitorização. Em 80% e 69% dos pacientes de G1 ou G2, respectivamente, as condições de intubação traqueal foram consideradas

  11. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  12. An inter-hospital comparison of patient dose based on clinical indications

    International Nuclear Information System (INIS)

    Teeuwisse, W.; Geleijns, J.; Veldkamp, W.

    2007-01-01

    Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 μSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals. (orig.)

  13. Preliminary study of the distribution of dose in patients with Graves' disease undergoing examination of uptake of iodine-131 using Monte Carlo simulation; Estudo preliminar da distribuicao de dose em pacientes com doenca de Graves submetidos a exame de captacao de iodo-131 utilizando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Schwarcke, Marcelo; Marques, Tatiana; Nicolucci, Patricia; Baffa, Oswaldo, E-mail: mschwarcke@usp.b [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica; Bornemann, Clarissa [Hospital de Caridade Astrogildo de Azevedo, Santa Maria, RS (Brazil). Servico de Medicina Nuclear de Santa Maria

    2010-06-15

    Patients with Graves disease have a high hormonal disorder, which causes behavioral changes. One way to treat this disease is the use of high doses of {sup 131} Iodine, requiring that the patient carries out the examination of {sup 131}I uptake to estimate the activity to be administered. Using these data capture and compared with the simulated data using the Monte Carlo code PENELOPE is possible to determine a distribution of dose to the region surrounding the thyroid. As noted the difference between the simulated values and the experimentally obtained were 10.36%, thus showing the code of simulation for accurate determination of absorbed dose in tissue near the thyroid. (author)

  14. Dose and induction to cancer risk evaluation associated to use of X ray body scanners by transmission at airports; Avaliacao da dose e do risco de inducao ao cancer associados ao uso de escaneres corporais de raios X por transmissao em aeroportos

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Samanda Cristine Arruda; Aquino, Josilto Oliveira de, E-mail: scorrea@cnen.gov.b, E-mail: josilto@cnen.gov.b [Comissao Nacional de Energia Nuclear (DIAPI/CGMI/CNEN), Rio de Janeiro, RJ (Brazil). Coordenacao Geral de Instalacoes Medicas e Industriais. Div. de Aplicacoes Industriais; Souza, Edmilson Monteiro de, E-mail: emonteiro@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CAPI/UEZO), Campo Grande, RJ (Brazil). Colegiado da Area de Producao Industrial; Silva, Ademir Xavier da, E-mail: ademir@nuclear.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    This paper uses the Monte Carlo MCNPX and the phantoms in male voxel and female voxel to evaluate the absorbed doses effective doses and the induction risk and the mortality due to cancer associated to exposures of individual submitted to X ray body scanners by transmission at various projections. The values of effective dose were calculated according to the recommended by the new ICRP 103 and the values of induction risks and mortality due to cancer were estimated through the document BEIR VII. (author)

  15. Evaluation of the use of a Business Intelligence system for management of patient radiation dose undergone to nuclear medicine exams; Avaliação do uso de um sistema de Business Intelligence para gerenciamento da dose de pacientes submetidos a exames de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, A.C.F.S.; Capaverde, A.S.; Moreira, M.N.; Moraes, A.L.; Andrade, J.R.M.; Bacelar, A., E-mail: acfischer@hcpa.edu.br [Hospital de Clínicas de Porto Alegre (HCPA), RS (Brazil). Serviço de Física Médica e Radioproteção

    2017-07-01

    The feasibility of using a Business Intelligence (BI) system, IMPAX BI (Agfa), to manage the effective radiation dose of patients undergoing Nuclear Medicine exams was evaluated. The evaluation was divided into four stages, using retrospective data from the activity administered to adult patients in the year 2016. It was possible with the system to create panels to filter the data by date and display them in table and / or graphs, indicating the estimated doses and established limits. The IMPAX BI system proved to be a tool capable of assisting in dose management in Nuclear Medicine since it facilitates the identification of cases in which the patient is submitted to doses higher than those defined in the protocols of exams.

  16. Study of the equivalent dose distribution in organs and tissues using periapical odontological radiography; Estudo da distribuição de dose equivalente em órgãos e tecidos em procedimento de radiografia odontológica periapical

    Energy Technology Data Exchange (ETDEWEB)

    Santos, H.F.S.; Cipeli, J.F.; Fortes, M.A.B.; Federico, C.A., E-mail: hannasantana.f@gmail.com [Instituto de Estudos Avançados (IEAv), São José dos Campos, SP (Brazil). Divisão de Física Aplicada; Bissoli, C.F. [Universidade Paulista (UNIP), São José dos Campos, SP (Brazil)

    2017-07-01

    In this article presents a study of the doses obtained in periapical odontological radiography in main tissues of the head, using thermoluminescent dosemeters of type TLD-700H applied to a anthropomorphic simulator. The results indicate that the skin and salivary glands received the highest doses and the risk of calculated injury was 1.44 x 10{sup -6} Sv{sup -1} per radiograph.

  17. Avaliação da tolerância e nefrotoxicidade do antimonial pentavalente administrado na dose de 40mg Sb v/kg/dia, de 12/12h, por 30 dias na forma cutaneo-mucosa de leishmaniose

    Directory of Open Access Journals (Sweden)

    Raimunda N.R. Sampaio

    1997-12-01

    Full Text Available Foi avaliada a função renal de 11 pacientes com leishmaniose cutâneo-mucosa tratados com antimonial pentavalente na dose de 40mg SbV/kg/dia aplicada de 12/12 horas, em esquema contínuo, durante trinta dias. No estudo, um paciente apresentou insuficiência renal reversível e dois desenvolveram alterações enzimáticas hepáticas e eletrocardiográficas sendo o esquema terapêutico interrompido. Nos demais pacientes observou-se efeitos nefrotóxicos tais como diminuição da taxa de filtração glomerular, diminuição da capacidade de concentração urinária, avaliada por um jejum hídrico de 16 horas e aumento na fração de excreção de sódio. No exame do sedimento urinário observou-se um aumento no número de leucócitos e cilindros. Os resultados encontrados neste estudo sugerem que o tratamento com antimonial pentavalente na dose de 40mg SbV/kg/dia foi menos tolerado em virtude de seus efeitos tóxicos, não parecendo apresentar índice de cura superior ao esquema atualmente preconizado de 20mg SbV/kg/dia.The renal function of eleven patients with mucocutaneous leishmaniasis was analyzed in a prospective study realized at the School Hospital of University of Brasília. The patients were treated with doses of 40mg/kg/day of pentavalent antimony (SbV, in a continuous scheme during thirty days. In this study three patients were excluded, one patient with reversible renal failure and two patients with hepatic and cardiac malfunctions. In the other eight patients, severe nephrotoxics effects were observed, like reduction of glomerular filtration rate, reduction of the urinary concentration capacity, evaluated by a sixteen hours hydric fasting and an increase of sodium fractional excretion. An increase in the number of leucocytes and cylinders were observed at the urinary sediment exam. Finally, the results shows that the treatment with pentavalent antimony in doses of 40mg Sb/kg/day was less tolerated on account of its renal toxics

  18. Avaliação da resposta bioquímica no câncer inicial de próstata: experiência uninstitucional comparando teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose Evaluation of biochemical response on early prostate cancer: comparison between treatment with external beam radiation alone and in combination with high-dose rate conformal brachytherapy boost

    Directory of Open Access Journals (Sweden)

    Douglas Guedes de Castro

    2004-08-01

    Full Text Available OBJETIVO: Análise comparativa da resposta bioquímica em pacientes submetidos à teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose para tumores localizados da próstata. MATERIAIS E MÉTODOS: De novembro de 1997 a janeiro de 2000, 74 pacientes foram submetidos à teleterapia com 45 Gy e reforço com braquiterapia de alta taxa de dose com irídio-192 e dose de 16 Gy em quatro inserções (BT. Estes foram comparados a 29 pacientes submetidos à teleterapia com 45 Gy e reforço com arcoterapia e dose mediana de 24 Gy (RT entre outubro de 1996 e fevereiro de 2000. Nos dois grupos houve associação ocasional de hormonioterapia neoadjuvante. Sobrevida atuarial livre de doença em três anos (SB3 e fatores prognósticos pré-tratamento da resposta bioquímica, como o antígeno prostático-específico inicial (PSAi, escore de Gleason da biópsia de próstata (EG e estádio clínico (EC, foram analisados. RESULTADOS: O seguimento mediano foi de 25 meses para o grupo RT e 37 meses para o BT. Na análise atuarial, a SB3 foi de 51% e 73% (p = 0,032 para RT e BT, respectivamente. Na análise estratificada pelo PSAi, a SB3 para RT e BT foi de 85,7% e 79,1% (p = 0,76 para PSAi 10 ng/mL, respectivamente. Quando estratificado pelo EG, a SB3 para RT e BT foi de 37% e 80% (p = 0,001 para EG 6 (p = 0,58; estratificando-se pelo EC, a SB3 para RT e BT foi de 36% e 74% (p = 0,018 para EC T2a (p = 0,692, respectivamente. O risco relativo bruto de recidiva bioquímica foi de 2,3 (95% IC: 1,0-5,1 para os pacientes tratados com RT, em relação à BT; quando ajustado pelo PSAi e EG, o risco relativo de recidiva bioquímica foi de 2,4 (95% IC: 1,0-5,7. CONCLUSÃO: A modalidade de tratamento foi fator prognóstico independente de recidiva bioquímica, com maior controle bioquímico associado à BT. Nossos resultados preliminares sugerem que o maior benefício com BT foi obtido nos pacientes com PSAi > 10 ng/mL, EC OBJECTIVE: To compare the

  19. COMPORTAMENTO DOS PARÂMETROS INDICATIVOS DE PRODUÇÃO DA BANANEIRA PACOVAN SUBMETIDA A DIFERENTES LÂMINAS DE IRRIGAÇÃO E DOSES DE POTÁSSIO NA CHAPADA DO APODI - LIMOEIRO DO NORTE-CE

    Directory of Open Access Journals (Sweden)

    SOLERNE CAMINHA COSTA

    2009-01-01

    Full Text Available The study was to evaluate the effect of the combination of different irrigation levels and rates of potassium applied drip on parameters indicative of the banana production Pacovan Apodi (var. SH3640. The experimental design was a randomized complete block with split plot and 3 replications. The treatments consisted of a combination of five layers of irrigation and drainage lysimeter by means for four doses of potassium applied by fertirrigation. The variables were the weight of the bunch without stalk, the number of hands in the bunch, the weight of the hand of the central cluster and the number of fruits of the central cluster of the bunch. The data were obtained from the harvest of the first two cycles of the experiment, from March 2006 to September 2007. The treatments with irrigation levels influenced in all tested parameters of production, while the doses of potassium only influenced the weight of the bunch without stalk.

  20. Thyroid absorbed dose using TLDs during mammography

    International Nuclear Information System (INIS)

    Gonzalez A, M.; Melendez L, M.; Davila M, P.

    2015-10-01

    Full text: In this study, the mean glandular dose (MGD) and the thyroid dose (D Thy) were measured in 200 women screened with mammography in Cranio caudal (Cc) and mediolateral oblique projections. All mammograms were performed with Giotto-Ims (6000-14-M2 Model) equipment, which was verified to meet the criteria of quality of NOM-229-Ssa-2002. During audits performance and HVL, for each anode filter combinations was measured with the camera Radcal mammography equipment 10 X 6-6M (HVL = 0.26 mm Al). D Thy measurements were performed with TLD dosimeters (LiF:Mn) , that were read with the Harshaw 3500 TLD reader. The MGD, was obtained according to the UK and European protocols for mammographic dosimetry using a plane parallel chamber (Standard Imaging, Model A-600) calibrated by a radiation beam UW-23-Mo (= 0.279 mm Al HVL). A comparative statistical analysis was carried out with the measured MGD and D thy. The thyroid mean dose was 0.063 mGy and 0.078 mGy for Cc and mediolateral oblique respectively. There is a linear correlation between the MGD and the D Thy slightly influenced by the anode-filter combination. Using a 95% for the confidence interval in MGD (1.07 mGy), the 90% of measurements are in agreement with the established uncertainty limits. The D Thy are lower than the MGD. There is no risk for cancer induction in thyroid in women due to mammography screening. (Author)

  1. Financial impact of outpatient clinic radioiodine therapy with sodium iodide I-131 for the treatment of patients with differentiated low-risk thyroid carcinoma in relation to hospital doses; Impacto financeiro da radioiodoterapia ambulatorial com iodeto de sódio I-131 para tratamento de pacientes com carcinoma diferenciado da tireóide de baixo risco em relação às doses hospitalares

    Energy Technology Data Exchange (ETDEWEB)

    Berenguer, P.F.; Chang, T.M.C.; Silva, R.A.M.; Neto, A.H.D.; Belo, I.B., E-mail: pricilaberenguer@gmail.com [Instituto de Medicina Integral Professor Fernando Figueira, Recife, PE (Brazil). Serviço de Medicina Nuclear; Santos, M.A.P. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife (Brazil). Coordenação de Radioproteção

    2017-07-01

    Differential thyroid carcinoma (CDT) is the most prevalent endocrine malignancy in the world, with an excellent prognosis and a 10-year survival rate of over 95%. By 2013, the lowest activity of I-131 authorized by the Brazilian Unified Health System (SUS) in the therapy of patients with low-risk CDT was 3,700 MBq, requiring hospitalization. Recent studies have shown similar effectiveness between low and high doses of I-131 in the treatment of low-risk CDT. In 2014, the Ministry of Health included in the list of SUS procedures the use of lower activities (1,110 MBq and 1,850 MBq) for this purpose. The Brazilian National Nuclear Energy Commission (CNEN) also authorized the outpatient use of activity up to 1,850 MBq of I-131. Objective: To evaluate the financial impact of the adoption of ambulatory radioiodine therapy in patients with CDT of low-risk when compared to the hospital dose. Methods: Analysis of patients with CDT low-risk who were treated with an outpatient dose of I-131 from August / 2014 to January / 2017 at a nuclear medicine service in Recife, PE, Brazil. The cost of outpatient versus hospital doses was calculated. Results: A total of 289 patients underwent low doses of iodine therapy were evaluated, resulting in a savings of R$227,793.80. Conclusion: Outpatient radioiodine therapy in the treatment of patients with CDT of low-risk resulted in a 61.10% reduction in SUS expense, in addition to enabling faster care.

  2. Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

    International Nuclear Information System (INIS)

    Afsharpour, Hossein; Beaulieu, Luc; Pignol, Jean-Philippe; Keller, Brian; Carrier, Jean-Francois; Reniers, Brigitte; Verhaegen, Frank

    2010-01-01

    The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast 103 Pd seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D 90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D 10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.

  3. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  4. Two-dose strategies for human papillomavirus vaccination: how well do they need to protect?

    Science.gov (United States)

    Jit, Mark; Choi, Yoon Hong; Laprise, Jean-François; Boily, Marie-Claude; Drolet, Mélanie; Brisson, Marc

    2014-05-30

    Two-dose human papillomavirus (HPV) vaccine schedules may provide short-term protection but their long-term population impact is unknown. Two models of HPV transmission and associated cervical disease (squamous and glandular, neoplasia and cancer) were fitted to data from England and Canada on HPV epidemiology, sexual behaviour, cervical screening outcomes and cervical cancer incidence. Models suggest that at 40-80% coverage, if two-dose schedules protect vaccinees for 20 years, then the benefits of the third dose are small. If two doses protect for 10 years, then the third dose may prevent as many cancers as the first two. At 80% coverage, numbers needed to receive a third dose to prevent an additional cancer are 5900-110,000 (England), 3000-5100 (Canada) with 20 years two-dose protection, and 2000-5300 (England), 760-950 (Canada) with 10 years two-dose protection. Results enable decision makers to quantify risks associated with two-dose schedules despite remaining uncertainties in vaccine duration and cross-protection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Avaliação da eficácia e segurança da associação de budesonida e formoterol em dose fixa e cápsula única no tratamento de asma não controlada: ensaio clínico randomizado, duplo-cego, multicêntrico e controlado Evaluation of the efficacy and safety of a fixed-dose, single-capsule budesonide-formoterol combination in uncontrolled asthma: a randomized, double-blind, multicenter, controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Roberto Stirbulov

    2012-08-01

    Full Text Available OBJETIVO: Avaliar a eficácia e a segurança da associação de budesonida e formoterol em dose fixa e cápsula única, em comparação ao uso de budesonida isolada em pacientes com asma não controlada. MÉTODOS: Ensaio clínico randomizado, duplo-cego, multicêntrico, de fase III, com grupos paralelos, comparando a eficácia de curto prazo e a segurança da formulação em pó de budesonida (400 µg e formoterol (12 µg com a formulação em pó de budesonida (400 µg em 181 participantes com asma não totalmente controlada. A idade dos participantes variou de 18-77 anos. Após um período de run-in de 4 semanas, durante o qual todos os participantes receberam budesonida duas vezes por dia, houve a randomização para um dos tratamentos do estudo. O tratamento foi administrado duas vezes ao dia por 12 semanas. Os principais desfechos foram VEF1, CVF e PFE matinal. Os dados foram analisados por intenção de tratar. RESULTADOS: O grupo tratado com a associação, quando comparado ao grupo budesonida isolado, teve uma melhora significativa no VEF1 (0,12 L vs. 0,02 L; p = 0.0129 e no PFE matinal (30,2 L/min vs. 6,3 L/min; p = 0,0004. Esses efeitos foram acompanhados por boa tolerabilidade e segurança, como demonstrado pela baixa frequência de eventos adversos menores. CONCLUSÕES: A associação em cápsula única de budesonida e formoterol mostrou ser eficaz e segura. Os resultados demonstram que essa formulação é uma opção terapêutica válida para a obtenção e manutenção do controle da asma.OBJECTIVE: To evaluate the efficacy and safety of a fixed-dose, single-capsule budesonide-formoterol combination, in comparison with budesonide alone, in patients with uncontrolled asthma. METHODS: This was a randomized, double-blind, multicenter, phase III, parallel clinical trial, comparing the short-term efficacy and safety of the combination of budesonide (400 µg and formoterol (12 µg, with those of budesonide alone (400 µg, both delivered

  6. Relative Composition of Fibrous Connective and Fatty/Glandular Tissue in Connective Tissue Grafts Depends on the Harvesting Technique but not the Donor Site of the Hard Palate.

    Science.gov (United States)

    Bertl, Kristina; Pifl, Markus; Hirtler, Lena; Rendl, Barbara; Nürnberger, Sylvia; Stavropoulos, Andreas; Ulm, Christian

    2015-12-01

    Whether the composition of palatal connective tissue grafts (CTGs) varies depending on donor site or harvesting technique in terms of relative amounts of fibrous connective tissue (CT) and fatty/glandular tissue (FGT) is currently unknown and is histologically assessed in the present study. In 10 fresh human cadavers, tissue samples were harvested in the anterior and posterior palate and in areas close to (marginal) and distant from (apical) the mucosal margin. Mucosal thickness, lamina propria thickness (defined as the extent of subepithelial portion of the biopsy containing ≤25% or ≤50% FGT), and proportions of CT and FGT were semi-automatically estimated for the entire mucosa and for CTGs virtually harvested by split-flap (SF) preparation minimum 1 mm deep or after deepithelialization (DE). Palatal mucosal thickness, ranging from 2.35 to 6.89 mm, and histologic composition showed high interindividual variability. Lamina propria thickness (P >0.21) and proportions of CT (P = 0.48) and FGT (P = 0.15) did not differ significantly among the donor sites (anterior, posterior, marginal, apical). However, thicker palatal tissue was associated with higher FGT content (P tissue composition in the hard palate, DE-harvested CTG contains much larger amounts of CT and much lower amounts of FGT than SF-harvested CTG, irrespective of the harvesting site.

  7. Expression of podoplanin and TGF-beta in glandular odontogenic cyst and its comparison with developmental and inflammatory odontogenic cystic lesions.

    Science.gov (United States)

    Alaeddini, Mojgan; Eshghyar, Nosratollah; Etemad-Moghadam, Shahroo

    2017-01-01

    The number of studies investigating the immunohistochemical characteristics of glandular odontogenic cysts (GOCs) is limited, due to its rarity. TGF-beta has been suggested to induce podoplanin expression in some lesions. We aimed to evaluate and compare podoplanin and TGF-beta expression in GOC and other odontogenic cystic lesions. A total of 43 samples including five GOCs, 10 dentigerous cysts (DCs), eight unicystic ameloblastoma (UAs), and 20 radicular cysts (RCs) were selected and subjected to immunohistochemical staining using monoclonal antibodies against podoplanin and TGF-beta. Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis along with Bonferroni for adjusting P-values (P < 0.05). Podoplanin immunoreactivity was observed in 80%, 70%, and 100% of DCs, RCs, and UAs, respectively, while none of the GOCs were positive for this marker (P = 0.004). Significant differences were only found in the GOC specimens. TGF-beta positivity occurred in the capsule and epithelium of all GOCs and DCs, while RCs and UAs demonstrated different expression percentages in the capsular and epithelial tissues. Epithelial TGF-beta showed significant differences among the studied lesions (P = 0.007) with the main difference found between DCs with RCs and DCs with UAs. Lack of podoplanin expression might be involved in the characteristic histologic and behavioral features of GOC, which seems to be unrelated to TGF-beta expression. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Development of an Expert System as a Diagnostic Support of Cervical Cancer in Atypical Glandular Cells, Based on Fuzzy Logics and Image Interpretation

    Directory of Open Access Journals (Sweden)

    Karem R. Domínguez Hernández

    2013-01-01

    Full Text Available Cervical cancer is the second largest cause of death among women worldwide. Nowadays, this disease is preventable and curable at low cost and low risk when an accurate diagnosis is done in due time, since it is the neoplasm with the highest prevention potential. This work describes the development of an expert system able to provide a diagnosis to cervical neoplasia (CN precursor injuries through the integration of fuzzy logics and image interpretation techniques. The key contribution of this research focuses on atypical cases, specifically on atypical glandular cells (AGC. The expert system consists of 3 phases: (1 risk diagnosis which consists of the interpretation of a patient’s clinical background and the risks for contracting CN according to specialists; (2 cytology images detection which consists of image interpretation (IM and the Bethesda system for cytology interpretation, and (3 determination of cancer precursor injuries which consists of in retrieving the information from the prior phases and integrating the expert system by means of a fuzzy logics (FL model. During the validation stage of the system, 21 already diagnosed cases were tested with a positive correlation in which 100% effectiveness was obtained. The main contribution of this work relies on the reduction of false positives and false negatives by providing a more accurate diagnosis for CN.

  9. Efeitos da associação entre pequenas doses subaracnóideas de morfina e cetoprofeno venoso e oral em pacientes submetidas à cesariana Efectos de la asociación entre pequeñas dosis subaracnóideas de morfina y cetoprofeno venoso y oral en pacientes sometidas a cesariana Effects of low spinal morphine doses associated to intravenous and oral ketoprofen in patients submitted to cesarean sections

    Directory of Open Access Journals (Sweden)

    Eliana Marisa Ganem

    2003-08-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Pequenas doses subaracnóideas de morfina são eficazes em reduzir a dor pós-operatória de pacientes submetidas à cesariana, com menor incidência de efeitos colaterais. O objetivo desta pesquisa foi avaliar a qualidade da analgesia pós-operatória e a ocorrência de efeitos colaterais em pacientes submetidas a cesarianas, sob anestesia subaracnóidea com bupivacaína hiperbárica e morfina nas doses de 0,05 mg e 0,1 mg, associadas ao cetoprofeno pelas vias venosa e oral. MÉTODO: Participaram do estudo 60 gestantes de termo, estado físico ASA I e II, que foram submetidas à cesariana eletiva. As pacientes foram divididas em dois grupos: grupo 1 - morfina 0,1 mg, grupo 2 - 0,05 mg, associada a 15 mg de bupivacaína hiperbárica. Todas receberam cetoprofeno (100 mg por via venosa no per-operatório e por via oral a cada 8 horas no primeiro dia de pós-operatório. As pacientes foram avaliadas 6, 12 e 24 horas após o término da cirurgia, com relação à intensidade da dor e presença de efeitos colaterais (sedação, prurido, náusea e vômito. A presença destes últimos também foi avaliada no per-operatório. RESULTADOS: Ambos os grupos foram idênticos quanto aos dados antropométricos e à duração da cirurgia e da anestesia. Também foram homogêneos com relação à intensidade da dor pós-operatória e à presença de prurido, sedação, náusea e vômito. CONCLUSÕES: A morfina, nas doses de 0,05 mg e 0,1 mg administradas no espaço subaracnóideo, associada ao cetoprofeno pelas vias venosa e oral, apresentou a mesma qualidade de analgesia pós-operatória e determinou a mesma ocorrência de efeitos colaterais.JUSTIFICATIVA Y OBJETIVOS: Pequeñas dosis subaracnóideas de morfina son eficaces en reducir el dolor pos-operatorio de pacientes sometidas a cesariana, con menor incidencia de efectos colaterales. El objetivo de esta pesquisa fue evaluar la calidad de la analgesia pos-operatoria y la ocurrencia

  10. Alternative Approach to Traumatic Stensen’s Duct Injuries Accompanied by Glandular Involvement: Botulinum Toxin Injection to the Gland in Conjunction with Microsurgical Repair of the Duct in an Acute Setting

    OpenAIRE

    Mert Çalış; Zeynep Öz; Hakan Uzun; Burçe Özgen; Alp Çetin3; Ali Emre Aksu

    2017-01-01

    Objective: The aim of this study was to evaluate the long-term results of a simultaneous application of botulinum toxin to the parotid gland in conjunction with the microsurgical repair of the duct in an acute setting and to encourage using botulinum toxin as a first-line option to prevent future complications associated with glandular involvement. Material and Methods: Three patients who were referred to the Plastic Surgery Clinic by the emergency room of the Hacettepe University Hospita...

  11. Evaluation of rate of unstable chromosomal changes in human blood irradiated by X-rays: establishment of dose-response curve; Avaliação da taxa de alterações cromossômicas instáveis em sangue humano irradiado por Raios x: estabelecimento de curva dose-resposta

    Energy Technology Data Exchange (ETDEWEB)

    Mendonça, J.C.G.; Mendes, M.E.; Melo, A.M.M.A., E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Silva, L.M.; Andrade, A.M.G.; Hwang, S.F.; Lima, F.F. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil). Lab. de Dosimetria Biológica

    2017-07-01

    Since the discovery of ionizing radiation, and consequently of its properties, there has been an increasing in its use, which in turn has raised concerns about the biological damage that it could cause in exposed individuals. As a result, cytogenetic dosimetry has emerged: a method that can be used as a complement or, in the absence of physical dosimetry, relating the frequency of chromosomal changes found in the blood of the exposed individual and the dose absorbed through dose-response calibration curves. This work aimed to verify the frequencies of the unstable chromosomal changes in human blood lymphocytes irradiated by X-rays of 250 kVp with different absorbed doses and later establish the dose-response calibration curves. The irradiation was performed at the CRCN-NE/CNEN-PE, Brazil metrology service on a PANTAK X-ray machine, model HF 320. The blood samples had their lymphocytes cultured in culture media and, after the processing, the metaphases were obtained. The chromosomal alterations analyzed were chromosomes dicentric, ring and isolated actinic fragments. There was an increase in frequencies of all chromosomal changes with increased absorbed dose. The calibration curves of dicentric and dicentric + rings presented good adjustments with the values of the coefficients Y = 0.0013 + 0.0271D + 0.0556D{sup 2} (X{sup 2} = 10.36 / GL = 6) and Y = 0.0013 + 0.0263D + 0.0640D{sup 2} (X{sup 2} = 7.43 / GL = 6), respectively. The establishment of these curves enables the Laboratory of Biological Dosimetry of the CRCN/NE/CNEN-PE to estimate the dose absorbed by occupationally exposed individuals and in cases of radiological accidents.

  12. Image quality and dose assessment in digital breast tomosynthesis: A Monte Carlo study

    International Nuclear Information System (INIS)

    Baptista, M.; Di Maria, S.; Oliveira, N.; Matela, N.; Janeiro, L.; Almeida, P.; Vaz, P.

    2014-01-01

    Mammography is considered a standard technique for the early detection of breast cancer. However, its sensitivity is limited essentially due to the issue of the overlapping breast tissue. This limitation can be partially overcome, with a relatively new technique, called digital breast tomosynthesis (DBT). For this technique, optimization of acquisition parameters which maximize image quality, whilst complying with the ALARA principle, continues to be an area of considerable research. The aim of this work was to study the best quantum energies that optimize the image quality with the lowest achievable dose in DBT and compare these results with the digital mammography (DM) ones. Monte Carlo simulations were performed using the state-of-the-art computer program MCNPX 2.7.0 in order to generate several 2D cranio-caudal (CC) projections obtained during an acquisition of a standard DBT examination. Moreover, glandular absorbed doses and photon flux calculations, for each projection image, were performed. A homogeneous breast computational phantom with 50%/50% glandular/adipose tissue composition was used and two compressed breast thicknesses were evaluated: 4 cm and 8 cm. The simulated projection images were afterwards reconstructed with an algebraic reconstruction tool and the signal difference to noise ratio (SDNR) was calculated in order to evaluate the image quality in DBT and DM. Finally, a thorough comparison between the results obtained in terms of SDNR and dose assessment in DBT and DM was performed. - Highlights: • Optimization of the image quality in digital breast tomosynthesis. • Calculation of photon energies that maximize the signal difference to noise ratio. • Projections images and dose calculations through the Monte Carlo (MC) method. • Tumor masses and microcalcifications included in the MC model. • A dose saving of about 30% can be reached if optimal photon energies are used

  13. Comparison between dose calculation in XiO Registered-Sign and dosimetric measurements in virtual wedge photon beams; Comparacao entre o calculo da dose no XiO Registered-Sign e medidas dosimetricas em feixes de fotons com filtro virtual

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Laila G.; Amaral, Leonardo L.; Oliveira, Harley F., E-mail: lailagalmeida@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia; Maia, Ana F. [Universidade Federal de Sergipe (UFS), Sao Cristovao (Sweden), (Brasil) Departamento de Fisica

    2012-08-15

    The virtual wedge is useful tool in the radiation treatment planning since it has series of advantages over the hard wedge. Quality control tests ensure correct performance of the planning done in treatment planning systems (TPS). This study aimed to compare doses calculated by TPS and doses measured by ionization chamber (CI) and an ionization chambers array in virtual wedge photon beams of 6 MV. Measures carried out in Primus linear accelerator with a solid water phantom and dosimeter positioned at 10 cm depth with gantry at 0 Degree-Sign in many fields sizes and angles in the virtual wedge. Measurements on the central axis used as dosimeter an IC and on off-axis used an IC array. The simulation in CMS-XiO used the CT images of the phantom in the same configuration of the irradiation. Maximum and minimum values of the percentage differences between the doses provided by TPS and measurements with ionization chamber on the central axis were 1.43 and -0.10%, respectively, with average percentage difference of 0.08% and confidence limit of {Delta}=1.72%. In the region off-axis, the average percentage difference was 0.04%, with a maximum of 1.9%, minimum of 0% and confidence limit of {Delta}=1.91%. All values for dose percentage differences were below 2% and lower confidence limit of 3% are thus, according to the recommendations of the Technical Report Series - TRS-430. (author)

  14. Study of the radiation scattered and produced by concrete shielding of radiotherapy rooms and its effects on equivalent doses in patients' organs; Estudo da radiacao espalhada e produzida pela blindagem de concreto de salas de radioterapia e seus efeitos sobre doses equivalentes nos orgaos dos pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Braga, K.L.; Rebello, W.F.; Andrade, E.R.; Gavazza, S.; Medeiros, M.P.C.; Mendes, R.M.S.; Gomes, R.G.; Silva, M.G., E-mail: kelmo.lins@gmail.com, E-mail: rebello@ime.eb.br, E-mail: fisica.dna@gmail.com, E-mail: sergiogavazza@yahoo.com, E-mail: eng.cavaliere@gmail.com, E-mail: raphaelmsm@gmail.com, E-mail: ggrprojetos@gmail.com, E-mail: maglosilva15@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear; Thalhofer, J.L.; Silva, A.X., E-mail: jardellt@yahoo.com.br, E-mail: ademir@con.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Energia Nuclear; Santos, R.F.G., E-mail: raphaelfgsantos@gmail.com [Centro Universitario Anhanguera, Niteroi, RJ (Brazil). Departamento de Engenharia

    2015-07-01

    Within a radiotherapy room, in addition to the primary beam, there is also secondary radiation due to the leakage of the accelerator head and the radiation scattering from room objects, patient and even the room's shielding itself, which is projected to protect external individuals disregarding its effects on the patient. This work aims to study the effect of concrete shielding wall over the patient, taking into account its contribution on equivalent doses. The MCNPX code was used to model the linear accelerator Varian 2100/2300 C/D operating at 18MeV, with MAX phantom representing the patient undergoing radiotherapy treatment for prostate cancer following Brazilian Institute of Cancer four-fields radiation application protocol (0°, 90°, 180° and 270°). Firstly, the treatment was patterned within a standard radiotherapy room, calculating the equivalent doses on patient's organs individually. In a second step, this treatment was modeled withdrawing the walls, floor and ceiling from the radiotherapy room, and then the equivalent doses calculated again. Comparing these results, it was found that the concrete has an average shielding contribution of around 20% in the equivalent dose on the patient's organs. (author)

  15. Quantitative model of evaluation of the contribution of each radioactive source in the individual external dose Hx in nuclear medicine service personnel; Modelo quantitativo de avaliacao da contribuicao de cada fonte radioativa na dose individual externa Hx em trabalhador de servico de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Nathalie Canhameiro; Tinois, Eduardo; Koga, Katia Hiromoto; Bezerra, Aline da Silva; Ferreira, Vinicius Capistrano; Azevedo, Thaisa Resende; Moriguchi, Sonia Marta, E-mail: soniamoriguchi@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2016-07-01

    Assess whether the activities performed in the Nuclear Medicine service are significant in the total dose received by the workers and their relative contributions. Methods: measured independent variables: number of scintigraphies remaining in the examination room (N); eluted activity (E); Total activity marked in pharmaceuticals kits (K); num-ber of times that was scheduled to work in the Hot room (Q); Variable dependent measured: cumulative effective dose in the period 10/2012 to 04/2013 added to each worker, obtained by information registered daily and monthly on activities and doses received in the period. Held Multiple Linear Regression (D = a + β{sub 1} N + E + β{sub 2} β{sub 3} K + β{sub 4} Q) with α = 0.05 significance level. It was concluded that the independent variables N (p = 0.097) and E (p = 0.086) did not significantly interfere with the Cumulative dose in the period. The K variables (p = 0.017) and Q (p = 0.028) were significant in the proposed model. (author)

  16. Study of distribution of doses in maintenance operations and interventions in restricted areas of IPEN's radiopharmacy center, Brazil; Estudo da distribuicao de doses em operacoes de manutencao e intervencao em areas restritas no Centro de Radiofarmacia do IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Jessica S.; Souza, Daiane C.; Rodrigues Junior, Orlando; Gerulis, Eduardo; Todo, Alberto S., E-mail: jsmachado@ipen.br, E-mail: dcsouza@ipen.br, E-mail: rodrijr@ipen.br, E-mail: egerulis@ipen.br, E-mail: astodo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (lPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    This research was developed at the Radiopharmacy Center of the Nuclear and Energy Research Institute - IPEN/CNEN/SP, Brazil, that performs the production of radiopharmaceuticals with isotopes of the {sup 131}I, {sup 123}I, {sup 201}Tl, {sup 67}Ga, {sup 18}F and {sup 99}Mo for use in nuclear medicine. The radioisotopes are produced on an industrial scale and the installation was designed to meet radiation safety standards and quality control requirements. To ensure the production, there are skilled professionals who perform the tasks of maintenance of the equipment and instruments, installed in the cells of processing of radiopharmaceuticals, without which it is not possible to conduct the work with safety and quality. This study was done a survey called Survey of Variables, based on the maintenance operations and interventions in restricted areas of the Centre of Radiopharmacy and in the survey of the distribution of doses in these tasks, carried out during the period from 2005 to 2011. This research aims to identify and determine the main variables that have an impact on the worker's dose. The results are presented for the Occupationally Exposed Individual variable, variable operation, variable area/Cell, task and Feature variable and variable duration of operation, depending on the Dose variable. It is intended in this way to contribute to improvements in operations in restricted areas that may result in lower individual doses without causing significant changes in the routine of work.

  17. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield; Emprego da radiacao gama do cobalto 60 em sementes de beterraba (Beta vulgaris L.), cenoura (Daucus carota L.) e rabanete (Raphanus sativus L.) para estimular o aumento da producao

    Energy Technology Data Exchange (ETDEWEB)

    Bovi, Jose Eduardo

    2000-07-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  18. Crescimento, trocas gasosas e potencial osmótico da bananeira-'Prata', submetida a diferentes doses de sódio e cálcio em solução nutritiva Growth, gaseous exchange and osmotic potential of banana 'Prata' plants, exposed to different concentrations of sodium and calcium in nutritive solution

    Directory of Open Access Journals (Sweden)

    LUDMILA LAFETÁ DE MELO NEVES

    2002-08-01

    Full Text Available O cálcio vem sendo utilizado com o intuito de incrementar tolerância a sais nas plantas, pois sabe-se que a salinidade restringe o crescimento e a produtividade de muitas culturas. Este estudo teve por objetivo avaliar os efeitos da aplicação de sódio e cálcio sobre o crescimento inicial, trocas gasosas e potencial osmótico da bananeira (Musa spp. 'Prata' (AAB. Foi utilizado o delineamento experimental em blocos casualizados, com arranjo fatorial 4 x 4 [ 4 doses de sódio ( 0; 5; 10; 15 mmol L-1 e 4 de cálcio ( 2; 4; 8; 12 mmol L-1] e 3 repetições. A emissão total de folhas e o potencial osmótico das plantas não foram influenciados pelos tratamentos. O aumento dos níveis de sódio na solução promoveu redução significativa na massa fresca da parte aérea, altura, área foliar, diâmetro do pseudocaule e massa seca das plantas. A presença de 5 mmol L-1 de Na na solução favoreceu as trocas gasosas. O aumento dos níveis de cálcio na solução promoveu a redução da massa fresca da parte aérea, altura e área foliar da bananeira-'Prata'.The Calcium has been used to increase salt tolerance in plants since salinity restricts growth and productivity in many crops. This study was conducted with the objective of evaluating the effects of sodium and calcium application on the initial growth, gaseous exchange and osmotic potential of banana (Musa spp. 'Prata' plants (AAB. The experimental layout was a 4 x 4 factorial with three replicates in a randomized complete block design. The factors tested were concentrations of sodium (0; 5; 10; 15 mmol L-1 and calcium (2; 4; 8; 12 mmol L-1. The total emition of leaves and the osmotic potential of the plants were not influenced by the treatments. However, the increase in concentrations of sodium in the nutritive solution resulted in significant reduction of the fresh weight of aerial plant parts, height and leaf area of the plants, diameter of the pseudostem, and dry weight of the plants. The

  19. Determination of the equivalent doses due to the ingestion of radionuclides from the uranium and thorium series presents in drinking waters of the region of Santa Luzia, Paraiba state, Brazil; Determinacao das doses equivalentes devido a ingestao de radionuclideos das series do uranio e torio presentes em aguas de consumo do municipio de Santa Luzia, estado da Paraiba

    Energy Technology Data Exchange (ETDEWEB)

    Pastura, Valeria F. da S., E-mail: vpastura@cnen.gov.b [Comissao Nacional de Energia Nuclear (DRSN/CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioprotecao e Seguranca Nuclear. Coordenacao de Materias Primas e Minerais; Campos, Thomas F. da C.; Petta, Reinaldo A., E-mail: thomascampos@geologia.ufrn.b, E-mail: petta@geologia.ufrn.b [Universidade Federal do Rio Grande do Norte (LARANA/UFRN), Natal, RN (Brazil). Lab. de Radioatividade Natural

    2011-10-26

    This paper determined the original dose equivalents from radionuclides of uranium and thorium series in a drinking water of well which is supplied to the population of Santa Luzia, Paraiba state, Brazil. The collected waters are near to the mineralized phlegmatic bodies in rose quartz and amazonite feldspar. Radiometric measurements performed on the feldspar vein point out counting ratios surrounding 30000 cps and the analysis of collected samples of minerals presented tenors for the {sup 226}Ra and {sup 219}Pb varying from 0.50 to 2.30 Bq/sw. For determination of concentration of radionuclides U{sub Total}, {sup 226}Ra, {sup 228}Ra and {sup 219}Pb, found in the not desalinated, two methods were used, spectrophotometry with arsenazo and radiochemistry, both realized in the CNEN-LAPOC laboratories. For the calculation of dose equivalent it was taken into consideration the following parameters: the dose coefficients for incorporation by ingestion for public individuals with ages over 17 years (Norma CNEN-NN-3.01, Regulatory Position 3.01/011) and daily ingestion of 4 liters of water, which is over the recommended by the WHO of 2L/day - 1993. The obtained values were compared with the reference value for compromised dose equivalent established by WHO for evaluate the risk potential to the health of population, by ingestion. The radionuclide concentrations in the wells varies from 0.054 to 0.21 Bq/L, resulting dose equivalents of 3.94 x 10{sup -3} mSv/year and 0.17 mSv/year in the studied population

  20. Alteration in the absorption cell dose arising from the use of gold nanoparticle associated with the radionuclides of clinical application: simulate study; Alteracao na absorcao de dose celular decorrente da utilizacao de nanoparticulas de ouro associadas a radionuclideos de aplicacao clinica: estudo simulado

    Energy Technology Data Exchange (ETDEWEB)

    Culik, Lucas; Schwarcke, Marcelo, E-mail: mschwarcke@unifra.br [Centro Universitario Franciscano (UNIFRA), Santa Maria, RS (Brazil)

    2015-12-15

    The present work is a proposal to assess, which is the efficiency in the use of radionuclides of clinical application in nuclear medicine service conjugated system with gold nanoparticles.To obtain the results needed for the interpretation of this combination, was using the Monte Carlo simulation code PENELOPE, where was the main structures of a simulated eukaryote cell. To simulate irradiation on cellular structures was used the emission spectrum of main radionuclide clinical use in nuclear medicine service. The material containing gold nanoparticles was modeled according the stoichiometric proportions found in the literature. The results obtained, present for the simulated energies to smaller bodies than 2,0μm, no substantial response to the use of nanoparticles in the reinforcement of locally absorbed dose. Is observed a small decrease in locally dose absorbed due to emission of charged particles, it is believed that causes an increase in the emission secondary range to be placed outside the study body. But this effect is small when comparing to the increase of energy absorbed due to interaction with the bodies containing nanoparticles, so demonstrating an increase in the locally dose absorbed. Being observed that there is an increase in dose absorbed locally due to the use of nanoparticles. For protocols based on the principle of target radionuclide therapy, the imaging of the treaty sit will be affected in their statistical accuracy, since the gamma radiation will be attenuated by the nanoparticles present in the material. Being necessary to know if this increase in the locally absorbed dose has greater importance in the treatment protocol than the image of the absorption of the radioactive material in the target organ. (author)