WorldWideScience

Sample records for cyp1a2 activity mammographic

  1. Effect of diethyldithiocarbamate (DDC) and ticlopidine on CYP1A2 activity and caffeine metabolism: an in vitro comparative study with human cDNA-expressed CYP1A2 and liver microsomes.

    Science.gov (United States)

    Kot, Marta; Daniel, Władysława A

    2009-01-01

    The aim of the present study was to test the effect of diethyldithiocarbamate (DDC), which is regarded as a cytochrome P450 (CYP) CYP2A6 and CYP2E1 inhibitor, and ticlopidine, an efficient CYP2B6, CYP2C19 and CYP2D6 inhibitor, on the activity of human CYP1A2 and the metabolism of caffeine (1-N-, 3-N- and 7-N-demethylation, and C-8-hydroxylation). The experiment was carried out in vitro using human cDNA-expressed CYP1A2 (Supersomes) and human pooled liver microsomes. The effects of DDC and ticlopidine were compared to those of furafylline (a strong CYP1A2 inhibitor). A comparative in vitro study provides clear evidence that ticlopidine and DDC, applied at concentrations that inhibit the above-mentioned CYP isoforms, potently (as compared to furafylline) inhibit human CYP1A2 and caffeine metabolism, in particular 1-N- and 3-N-demethylation.

  2. Influence of the urine flow rate on some caffeine metabolite ratios used to assess CYP1A2 activity.

    Science.gov (United States)

    Sinués, Blanca; Fanlo, Ana; Bernal, María Luisa; Mayayo, Esteban; Soriano, María Antonia; Martínez-Ballarin, Enrique

    2002-12-01

    Five established metabolite ratios (MRs) to measure P450 CYP1A2 activity--MR1 (17X + 17U)/137X, MR2 (AFMU + 1X + 1U)/17U, MR3 (17X/137X), MR4 (AFMU + 1X + 1U + 17X + 17U)/137X, and MR5 (AFMU + 1X + 1U)/17X--were calculated in urine 4-5 hours after caffeine intake. First, to assess the potential of omeprazole to induce CYP1A2 activity, a caffeine test was performed in 27 subjects on two occasions: before and after 14 days on omeprazole (20 mg/day). Samples of urine were analyzed by high-performance liquid chromatography (HPLC) to quantify caffeine and metabolites used to calculate the different caffeine MRs. MR1, MR3, and MR4 were enhanced after treatment; the percentage of change was inversely associated with that of the urine flow, with r values of -0.48, -0.49, and -0.47, respectively. However, MR2 or MR5 were not modified. To determine the reason for these contradictory results, the authors analyzed data of metabolites, ratios, and their components (numerators and denominators) from 152 subjects (who underwent one caffeine test) and their relationship with the urinary flow. Caffeine concentration in urine was the only compound nondependent on the urine flow. Consistently, ratios containing caffeine (MR1, MR3, and MR4) were highly influenced by the rate of urine excretion, since the flow dependence of their numerators is not canceled out by that of caffeine in their denominators. The dependency of the caffeine excretion on renal factors may explain the opposite results found with the different ratios in the aforementioned prospective study of drug interaction, the absence of closer correlations of the five MRs to each other, the discrepancies about the type of frequency distribution of the different MRs (either normal or multimodal), and the higher sensitivity of MR2 to detect gender differences in CYP1A2 activity found in this study. In summary, the data clearly emphasize the need for a strict control of the liquid intake to avoid high urine flows when MRs

  3. Systemic uptake of miconazole during vaginal suppository use and effect on CYP1A2 and CYP3A4 associated enzyme activities in women

    DEFF Research Database (Denmark)

    Kjærstad, Mia Birkhøj; Nielsen, Flemming; Nøhr-Jensen, Lene

    2010-01-01

    To investigate if the ordinary use of a vaginal suppository containing miconazole results in systemic absorption that is sufficient to affect the activities of CYP1A2 and CYP3A4, which are major drug- and steroid-metabolising enzymes.......To investigate if the ordinary use of a vaginal suppository containing miconazole results in systemic absorption that is sufficient to affect the activities of CYP1A2 and CYP3A4, which are major drug- and steroid-metabolising enzymes....

  4. Inhibition of Procarcinogen Activating Enzyme CYP1A2 Activity and Free Radical Formation by Caffeic Acid and its Amide Analogues.

    Science.gov (United States)

    Narongchai, Paitoon; Niwatananun, Kanokporn; Narongchai, Siripun; Kusirisin, Winthana; Jaikang, Churdsak

    2016-01-01

    Caffeic acid (CAF) and its amide analogues, ethyl 1-(3',4'-dihydroxyphenyl) propen amide (EDPA), phenethyl 1-(3',4'-dihydroxyphenyl) propen amide (PEDPA), phenmethyl 1- (3',4'-dihydroxyphenyl) propen amide (PMDPA) and octyl 1-(3',4'-dihydroxyphenyl) propen amide (ODPA) were investigated for the inhibition of procarcinogen activating enzyme. CYP1A2 and scavenging activity on formation of nitric oxide, superoxide anion, DPPH radical and hydroxyl radical. It was found that they inhibited CYP1A2 enzyme by uncompetitive inhibition. Apparent Ki values of CAF, EDPA, PEDPA, PMDPA and ODPA were 0.59, 0.39, 0.45, 0.75 and 0.80 µM, respectively suggesting potent inhibitors of CYP1A2. Moreover, they potentially scavenged nitric oxide radical with IC 50 values of 0.12, 0.22, 0.28, 0.22 and 0.51 mM, respectively. The IC50 values of superoxide anion scavenging were 0.20, 0.22, 0.44, 2.18 and 2.50 mM, respectively. 1, 1- diphenyl-2- picrylhydrazyl (DPPH) radical-scavenging ability, shown as IC50 values, were 0.41, 0.29, 0.30, 0.89 and 0.84 mM, respectively. Moreover, the hydroxyl radical scavenging in vitro model was shown as IC50 values of 23.22, 21.06, 17.10, 17.21 and 15.81 µM, respectively. From our results, caffeic acid and its amide analogues are in vitro inhibitors of human CYP1A2 catalytic activity and free radical formation. They may be useful to be developed as potential chemopreventive agents that block CYP1A2-mediated chemical carcinogenesis.

  5. The influence of CYP1A2 genotype in the blood pressure response to caffeine ingestion is affected by physical activity status and caffeine consumption level.

    Science.gov (United States)

    Soares, Rogerio Nogueira; Schneider, Augusto; Valle, Sandra Costa; Schenkel, Paulo Cavalheiro

    2018-03-06

    This study aimed to investigate whether the influence of CYP1A2 genotype in the blood pressure (BP) response to caffeine ingestion was affected by physical activity status and habitual caffeine consumption. Thirty-seven participants (19-50 years old) took place in the study and were categorized according to i) genotype: CYP1A2 (AA) "fast metabolizer", and CYP1A2 (AC) "slow metabolizer"; ii) physical activity level: sedentary (S) and physically active (A); and iii) caffeine consumption level: non-habitual caffeine consumer (NC) and habitual heavy caffeine consumer (C). All groups had BP assessed before (basal) and 1 hourh after (post) caffeine ingestion (6 mg·kg -1 ). It was observed that AC genotype individuals had increased basal-DBP and post-caffeine SBP when compared to AA individuals. Additionally, acute caffeine ingestion increased SBP only in the AC group. It was also found that physical activity only modulated the BP responses to acute caffeine ingestion in AC individuals. Furthermore, the results indicated that the habitual heavy caffeine consumers AC individuals had increased basal-DBP when compared to the AA ones. Our results suggest that the influence of CYP1A2 genotype in the basal and post-caffeine BP response to caffeine ingestion is modified by physical activity status and caffeine consumption level. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Coffee and tea consumption, genotype-based CYP1A2 and NAT2 activity and colorectal cancer risk—Results from the EPIC cohort study

    NARCIS (Netherlands)

    Dik, V.K.; Bueno-de-Mesquita, H.B.; Oijen, van M.G.C.T.; Siersema, P.D.; Uiterwaal, C.S.P.M.; Gils, van C.H.; Duijnhoven, van F.J.B.

    2014-01-01

    Coffee and tea contain numerous antimutagenic and antioxidant components and high levels of caffeine that may protect against colorectal cancer (CRC). We investigated the association between coffee and tea consumption and CRC risk and studied potential effect modification by CYP1A2 and NAT2

  7. Evaluation of toxic equivalency factors for induction of cytochromes P450 CYP1A1 and CYP1A2 enzyme activity by dioxin-like compounds

    International Nuclear Information System (INIS)

    Toyoshiba, Hiroyoshi; Walker, Nigel J.; Bailer, A. John; Portier, Christopher J.

    2004-01-01

    The toxic equivalency factor (TEF) method has been used to characterize the toxicity of human mixtures of dioxin-like compounds and is being considered for use with other classes of potentially toxic agents. TEFs are estimated by examining the relative potencies of the various congeners for a series of biological and toxicological effects. In this paper, we consider changes in activity for two enzymes, cytochrome P450 1A1 (CYP1A1)-associated 7-ethoxyresorufin-O-deethylase (EROD) and CYP1A2-associated acetanilide-4-hydroxylase (A4H) activity, resulting from exposure to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 3,3',4,4',5-pentachlorobiphenyl (PCB), 2,3,4,7,8-pentachlorodibenzofuran (PeCDF) or a mixture of these agents. The ratio of median effective dose (ED 50 ) is one way to estimate the relative potencies, especially for gene expression and protein endpoints. ED 50 's were estimated with a nonlinear regression model in which dose-related changes in mean responses are described by a Hill function. ED 50 's along with other model parameters were estimated by fitting this model to a given data set. Significant differences in estimated model parameters were tested by likelihood ratio methods. The estimated parameters indicated that congener-specific dose-response shapes were significantly different, that additivity failed for these congeners, and that the ratios of ED 50 's did not predict the response seen for the mixture. These results indicate that for some biological responses, the use of a single relative potency factor (RPF) is not appropriate for the comparison of the dose response behavior of different dioxin-like congeners

  8. Genetic polymorphisms of cytochrome P450-1A2 (CYP1A2 among Emiratis.

    Directory of Open Access Journals (Sweden)

    Mohammad M Al-Ahmad

    Full Text Available Cytochrome P450 1A2 (CYP1A2 is one of the CYP450 mixed-function oxidase system that is of clinical importance due to the large number of drug interactions associated with its induction and inhibition. In addition, significant inter-individual differences in the elimination of drugs metabolized by CYP1A2 enzyme have been observed which are largely due to the highly polymorphic nature of CYP1A2 gene. However, there are limited studies on CYP1A2 phenotypes and CYP1A2 genotypes among Emiratis and thus this study was carried out to fill this gap. Five hundred and seventy six non-smoker Emirati subjects were asked to consume a soft drink containing caffeine (a non-toxic and reliable probe for predicting CYP1A2 phenotype and then provide a buccal swab along with a spot urine sample. Taq-Man Real Time PCR was used to determine the CYP1A2 genotype of each individual. Phenotyping was carried out by analyzing the caffeine metabolites using High Performance Liquid Chromatography (HPLC analysis. We found that 1.4%, 16.3% and 82.3% of the Emirati subjects were slow, intermediate and rapid CYP1A2 metabolizers, respectively. In addition, we found that 1.4% of the subjects were homozygote for derived alleles while 16.1% were heterozygote and 82.5% were homozygote for the ancestral allele. The genotype frequency of the ancestral allele, CYP1A2*1A/*1A, is the highest in this population, followed by CYP1A2 *1A/*1C and CYP1A2 *1A/*1K genotypes, with frequencies of 0.825, 0.102 and 0.058, respectively. The degree of phenotype/genotype concordance was equal to 81.6%. The CYP1A2*1C/*1C and CYP1A2*3/*3 genotypes showed significantly the lowest enzyme phenotypic activity. The frequency of slow activity CYP1A2 enzyme alleles is very low among Emiratis which correlates with the presence of low frequencies of derived alleles in CYP1A2 gene.

  9. Comparison of CYP1A2 and NAT2 phenotypes between black and white smokers.

    Science.gov (United States)

    Muscat, Joshua E; Pittman, Brian; Kleinman, Wayne; Lazarus, Philip; Stellman, Steven D; Richie, John P

    2008-10-01

    The lower incidence rate of transitional cell carcinoma of the urinary bladder in blacks than in whites may be due to racial differences in the catalytic activity of enzymes that metabolize carcinogenic arylamines in tobacco smoke. To examine this, we compared cytochrome P4501A2 (CYP1A2) and N-acetyltransferase-2 activities (NAT2) in black and white smokers using urinary caffeine metabolites as a probe for enzyme activity in a community-based study of 165 black and 183 white cigarette smokers. The paraxanthine (1,7-dimethylxanthine, 17X)/caffeine (trimethylxanthine, 137X) ratio or [17X+1,7-dimethyluric acid (17U)]/137X ratio was used as an indicator of CYP1A2 activity. The 5-acetyl-amino-6-formylamino-3-methyluracil (AFMU)/1-methylxanthine (1X) ratio indicated NAT2 activity. The odds ratio for the slow NAT2 phenotype associated with black race was 0.4; 95% confidence intervals 0.2-0.7. The putative combined low risk phenotype (slow CYP1A2/rapid NAT2) was more common in blacks than in whites (25% vs. 15%, Pwhites.

  10. Scutellarin inhibits cytochrome P450 isoenzyme 1A2 (CYP1A2) in rats.

    Science.gov (United States)

    Jian, Tun-Yu; He, Jian-Chang; He, Gong-Hao; Feng, En-Fu; Li, Hong-Liang; Bai, Min; Xu, Gui-Li

    2012-08-01

    Scutellarin is the most important flavone glycoside in the herbal drug Erigeron breviscapus (Vant.) Hand.-Mazz. It is used frequently in the clinic to treat ischemic vascular diseases in China. However, the direct relationship between scutellarin and cytochrome P450 (CYP450) is unclear. The present study investigated the in vitro and in vivo effects of scutellarin on cytochrome P450 1A2 (CYP 1A2) metabolism. According to in vitro experiments, scutellarin (10-250 µM) decreased the formation of 4-acetamidophenol in a concentration-dependent manner, with an IC₅₀ value of 108.20 ± 0.657 µM. Furthermore, scutellarin exhibited a weak mixed-type inhibition against the activity of CYP1A2 in rat liver microsomes, with a K(i) value of 95.2 µM. Whereas in whole animal studies, scutellarin treatment for 7 days (at 5, 15, 30 mg/kg, i.p.) decreased the clearance (CL), and increased the T(1/2) (at 15, 30 mg/kg, i.p.), it did not affect the V(d) of phenacetin. Scutellarin treatment (at 5, 15, 30 mg/kg, i.p.) increased the AUC(0-∞) by 14.3%, 67.3% and 159.2%, respectively. Scutellarin at 30 mg/kg also weakly inhibited CYP1A2 activity, in accordance with our in vitro study. Thus, the results indicate that CYP1A2 is inhibited directly, but weakly, by scutellarin in vivo, and provide useful information on the safe and effective use of scutellarin in clinical practice. Copyright © 2012 John Wiley & Sons, Ltd.

  11. The effect of lycopene on the total cytochrome P450, CYP1A2 and CYP2E1

    Directory of Open Access Journals (Sweden)

    Melva Louisa

    2009-12-01

    Full Text Available Aim: Some carotenoids such as canthaxantin, astaxanthin and beta apo-8’-carotenal were reported to have modulatoryeffect on the cytochrome P450. The present study was conducted to investigate the effects of lycopene, a nonprovitamin A carotenoid, on microsomal cytochrome P450, CYP1A2 and CYP2E1.Methods: Total cytochrome P450 levels, CYP1A2 and CYP2E1-catalyzed reactions (acetanilide 4-hydroxylation and p-nitrophenol hydroxylation were studied in the liver microsomes of male Sprague Dawley rats. Microsomes were prepared using differential centrifugation combined with calcium aggregation method. Lycopene was orally administered in the dosages of 0, 25, 50 or 100 mg/kgBW/day for 14 days in a repeated fashion. Data were analyzed using ANOVA test.Results: Total cytochrome P450 level and acetanilide 4-hydroxylase activity were unaffected by any of the treatments. The CYP2E1 probe enzyme (p-nitrophenol hydroxylase was significantly reduced by repeated administration of 100mg/ kgBW/day lycopene (7.88 + 2.04 vs 12.26 + 2.77 n mol/min/mg prot.Conclusion: The present results suggest that lycopene does not affect the total cytochrome P450 or CYP1A2 activity but it inhibits the activity of CYP2E1 (p-nitrophenol hydroxylase in the rat. (Med J Indones 2009; 18: 233-8Keywords: lycopene, cytochrome P450, CYP1A2, CYP2E1

  12. Hexachlorobenzene stimulates uroporphyria in low affinity AHR mice without increasing CYP1A2

    International Nuclear Information System (INIS)

    Gorman, Nadia; Trask, Heidi S.; Robinson, Susan W.; Sinclair, Jacqueline F.; Gerhard, Glenn S.; Smith, Andrew G.; Sinclair, Peter R.

    2007-01-01

    Hexachlorobenzene (HCB), a weak ligand of the aryl hydrocarbon receptor (AHR), causes hepatic uroporphyrin (URO) accumulation (uroporphyria) in humans and animals. CYP1A2 has been shown to be necessary in the development of uroporphyria in mice. Using mice expressing the low affinity form of the AH receptor (AHRd), we investigated whether the enhancement of uroporphyria by HCB involves an obligatory increase in CYP1A2 as measured by specific enzyme assays and immunoblotting. We compared the ability of HCB, in combination with iron dextran and the porphyrin precursor, 5-aminolevulinate (ALA), to cause uroporphyria in a strain of mice (C57BL/6) which expresses the high affinity form of the receptor (AHRb 1 ), with three strains of mice (SWR and two 129 sublines) expressing the low affinity AHRd. In C57BL/6 mice, HCB-enhanced uroporphyria was associated with a doubling of CYP1A2. HCB treatment produced uroporphyria in iron-loaded mice expressing AHRd, even though there was little or no increase in CYP1A2. Cyp1a2(-/-) mice in a 129 background were completely resistant to HCB-induced uroporphyria, and female Hfe(-/-) 129 mice, in which the levels of hepatic CYP1A2 were half of those of the male levels, responded poorly. The effect of exogenous iron, administered in the form of iron dextran, on HCB enhancement of uroporphryia could be replicated utilizing the endogenous hepatic iron accumulated in 129 Hfe(-/-) mice. In conclusion, some minimal basal expression of CYP1A2 is essential for HCB-mediated enhancement of uroporphyria, but increases in CYP1A2 above that level are not essential

  13. Upregulation of microRNA-320 decreases the risk of developing steroid-induced avascular necrosis of femoral head by inhibiting CYP1A2 both in vivo and in vitro.

    Science.gov (United States)

    Wei, Ji-Hua; Luo, Qun-Qiang; Tang, Yu-Jin; Chen, Ji-Xia; Huang, Chun-Lan; Lu, Ding-Gui; Tang, Qian-Li

    2018-06-20

    Steroid-induced avascular necrosis of femoral head (SANFH) occurs frequently in patients receiving high-dose steroid treatment for these underlying diseases. The target of this study is to investigate the effect of microRNA-320 (miR-320) on SANFH by targeting CYP1A2. CYP1A2 expression was detected using immunohistochemistry. Specimens were collected from patients with SANFH and femoral neck fracture. Seventy rats were assigned into seven groups. The targeting relationship between miR-320 and CYP1A2 was verified by bioinformatics website and dual luciferase reporter gene assay. RT-qPCR and Western blot analysis were used to detect miR-320 and CYP1A2 expressions. The enzymatic activity of CYP1A2 was detected by fluorescence spectrophotometry. Hemorheology and microcirculation were measured in rats. MiR-320 expression decreased and CYP1A2 expression and enzymatic activity increased in SANFH patients compared to those with femoral neck fracture. CYP1A2 was the target gene of miR-320. Hemorheology and microcirculation results showed that up-regulated expression of CYP1A2 promoted the development of SANFH while increased expression of miR-320 inhibited the development of SANFH. Compared with the SANFH group, the SANFH + miR-320 mimic group showed increased miRNA-320 expression, and decreased CYP1A2 expression and enzymatic activity. Opposite results were found in the SANFH + miR-320 inhibitor group. The SANFH + miR-320 inhibitor + pCR-CYP1A2_KO group showed decreased miRNA-320 expression and the SANFH + pCR-CYP1A2_KO group showed decreased CYP1A2 expression and enzymatic activity. Our findings provide evidences that miR-320 might inhibit the development of SANFH by targeting CYP1A2. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Gene-Environment Interaction in Parkinson's Disease: Coffee, ADORA2A, and CYP1A2.

    Science.gov (United States)

    Chuang, Yu-Hsuan; Lill, Christina M; Lee, Pei-Chen; Hansen, Johnni; Lassen, Christina F; Bertram, Lars; Greene, Naomi; Sinsheimer, Janet S; Ritz, Beate

    2016-01-01

    Drinking caffeinated coffee has been reported to provide protection against Parkinson's disease (PD). Caffeine is an adenosine A2A receptor (encoded by the gene ADORA2A) antagonist that increases dopaminergic neurotransmission and Cytochrome P450 1A2 (gene: CYP1A2) metabolizes caffeine; thus, gene polymorphisms in ADORA2A and CYP1A2 may influence the effect coffee consumption has on PD risk. In a population-based case-control study (PASIDA) in Denmark (1,556 PD patients and 1,606 birth year- and gender-matched controls), we assessed interactions between lifetime coffee consumption and 3 polymorphisms in ADORA2A and CYP1A2 for all subjects, and incident and prevalent PD cases separately using logistic regression models. We also conducted a meta-analysis combining our results with those from previous studies. We estimated statistically significant interactions for ADORA2A rs5760423 and heavy vs. light coffee consumption in incident (OR interaction = 0.66 [95% CI 0.46-0.94], p = 0.02) but not prevalent PD. We did not observe interactions for CYP1A2 rs762551 and rs2472304 in incident or prevalent PD. In meta-analyses, PD associations with daily coffee consumption were strongest among carriers of variant alleles in both ADORA2A and CYP1A2. We corroborated results from a previous report that described interactions between ADORA2A and CYP1A2 polymorphisms and coffee consumption. Our results also suggest that survivor bias may affect results of studies that enroll prevalent PD cases. © 2017 S. Karger AG, Basel.

  15. CYP1A2 Genotype Variations Do Not Modify the Benefits and Drawbacks of Caffeine during Exercise: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Juan J. Salinero

    2017-03-01

    Full Text Available Previous investigations have determined that some individuals have minimal or even ergolytic performance effects after caffeine ingestion. The aim of this study was to analyze the influence of the genetic variations of the CYP1A2 gene on the performance enhancement effects of ingesting a moderate dose of caffeine. In a double-blind randomized experimental design, 21 healthy active participants (29.3 ± 7.7 years ingested 3 mg of caffeine per kg of body mass or a placebo in testing sessions separated by one week. Performance in the 30 s Wingate test, visual attention, and side effects were evaluated. DNA was obtained from whole blood samples and the CYP1A2 polymorphism was analyzed (rs762551. We obtained two groups: AA homozygotes (n = 5 and C-allele carriers (n = 16. Caffeine ingestion increased peak power (682 ± 140 vs. 667 ± 137 W; p = 0.008 and mean power during the Wingate test (527 ± 111 vs. 518 ± 111 W; p < 0.001 with no differences between AA homozygotes and C-allele carriers (p > 0.05. Reaction times were similar between caffeine and placebo conditions (276 ± 31 vs. 269 ± 71 milliseconds; p = 0.681 with no differences between AA homozygotes and C-allele carriers. However, 31.3% of the C-allele carriers reported increased nervousness after caffeine ingestion, while none of the AA homozygotes perceived this side effect. Genetic variations of the CYP1A2 polymorphism did not affect the ergogenic effects and drawbacks derived from the ingestion of a moderate dose of caffeine.

  16. CYP1A2 Genotype Variations Do Not Modify the Benefits and Drawbacks of Caffeine during Exercise: A Pilot Study.

    Science.gov (United States)

    Salinero, Juan J; Lara, Beatriz; Ruiz-Vicente, Diana; Areces, Francisco; Puente-Torres, Carlos; Gallo-Salazar, César; Pascual, Teodoro; Del Coso, Juan

    2017-03-11

    Previous investigations have determined that some individuals have minimal or even ergolytic performance effects after caffeine ingestion. The aim of this study was to analyze the influence of the genetic variations of the CYP1A2 gene on the performance enhancement effects of ingesting a moderate dose of caffeine. In a double-blind randomized experimental design, 21 healthy active participants (29.3 ± 7.7 years) ingested 3 mg of caffeine per kg of body mass or a placebo in testing sessions separated by one week. Performance in the 30 s Wingate test, visual attention, and side effects were evaluated. DNA was obtained from whole blood samples and the CYP1A2 polymorphism was analyzed (rs762551). We obtained two groups: AA homozygotes ( n = 5) and C-allele carriers ( n = 16). Caffeine ingestion increased peak power (682 ± 140 vs. 667 ± 137 W; p = 0.008) and mean power during the Wingate test (527 ± 111 vs. 518 ± 111 W; p 0.05). Reaction times were similar between caffeine and placebo conditions (276 ± 31 vs. 269 ± 71 milliseconds; p = 0.681) with no differences between AA homozygotes and C-allele carriers. However, 31.3% of the C-allele carriers reported increased nervousness after caffeine ingestion, while none of the AA homozygotes perceived this side effect. Genetic variations of the CYP1A2 polymorphism did not affect the ergogenic effects and drawbacks derived from the ingestion of a moderate dose of caffeine.

  17. Coffee, ADORA2A, and CYP1A2: the caffeine connection in Parkinson's disease.

    Science.gov (United States)

    Popat, R A; Van Den Eeden, S K; Tanner, C M; Kamel, F; Umbach, D M; Marder, K; Mayeux, R; Ritz, B; Ross, G W; Petrovitch, H; Topol, B; McGuire, V; Costello, S; Manthripragada, A D; Southwick, A; Myers, R M; Nelson, L M

    2011-05-01

    In 1-methyl-4-phenyl 1,2,3,6-tetrahydropyridine animal models of Parkinson's disease (PD), caffeine protects neurons by blocking the adenosine receptor A2A (ADORA2A). Caffeine is primarily metabolized by cytochrome P450 1A2 (CYP1A2). Our objective was to examine whether ADORA2A and CYP1A2 polymorphisms are associated with PD risk or modify the caffeine-PD association. Parkinson's Epidemiology and Genetic Associations Studies in the United States (PEGASUS) included five population-based case-control studies. One laboratory genotyped four ADORA2A and three CYP1A2 polymorphisms in 1325 PD cases and 1735 age- and sex-matched controls. Information regarding caffeine (coffee) consumption and other lifestyle factors came from structured in-person or telephone interviews. Odds ratios (OR) and 95% confidence intervals (CI) were estimated using logistic regression. Two ADORA2A polymorphisms were inversely associated with PD risk - rs71651683, a 5' variant (adjusted allelic OR = 0.51, 95% CI 0.33-0.80, permutation-adjusted P = 0.015) and rs5996696, a promoter region variant (adjusted OR for AC and CC genotypes compared with the AA wild-type genotype were 0.76 (95% CI 0.57-1.02) and 0.37 (95% CI 0.13-1.01), respectively (permutation-adjusted P for trend = 0.04). CYP1A2 polymorphisms were not associated with PD risk; however, the coffee-PD association was strongest among subjects homozygous for either variant allele rs762551 (P(interaction) = 0.05) or rs2470890 (P(interaction) = 0.04). In this consortium study, two ADORA2A polymorphisms were inversely associated with PD risk, but there was weak evidence of interaction with coffee consumption. In contrast, the coffee-PD association was strongest among slow metabolizers of caffeine who were homozygous carriers of the CYP1A2 polymorphisms. © 2011 The Author(s). European Journal of Neurology © 2011 EFNS.

  18. Pilot Study on Genetic Polymorphisms CYP1A2*1F on Asthma Patients and Nonasthma in Indonesia

    Directory of Open Access Journals (Sweden)

    Doddy de Queljoe

    2015-03-01

    Full Text Available Genetic polymorphisms of CYP1A2 is related to the theophylline metabolism that may affect drug levels in the blood, which can also affect incidence of adverse drug reaction (ADR and clinical outcomes of asthma therapy. The frequency of CYP1A2 polymorphism is known to vary among ethnic. Allegedly the Indonesian population has high frequency of gene variants of CYP1A2*1F. This study aims to determine the profile of CYP1A2*1F gene polymorphism in a sample of nonasthma and asthma in Indonesia with other populations based on the literature. Data were taken on January–June 2014. Blood samples were obtained from 29 nonasthma samples and 16 patients with asthma. After extraction of genomic DNA, CYP1A2*1F gene polymorphisms determined by PCR-RFLP. The results of this study indicate that the CYP1A2*1F gene polymorphism in nonasthma samples was 10.35% (3/29 for C/C, 37.93% (11/29 for the C/A, and 51.72% (15/29 for A/A. The asthmatics genotype have a frequency distribution of C/A genotype of 81.25% (13/16 and A/A of 18.75% (3/16. There was no significant difference (p=0.276 allele frequencies between samples of nonasthma and asthma patients. The frequency of CYP1A2*1F gene in Indonesian population is higher than the population of Egypt, Japan, and UK, but lower compared to Malaysia. It can be concluded that there is no difference in frequency.

  19. Gene-environment interaction in Parkinson’s disease: coffee, ADORA2A, and CYP1A2

    Science.gov (United States)

    Chuang, Yu-Hsuan; Lill, Christina M.; Lee, Pei-Chen; Hansen, Johnni; Lassen, Christina Funch; Bertram, Lars; Greene, Naomi; Sinsheimer, Janet S.; Ritz, Beate

    2017-01-01

    Background and purpose Drinking caffeinated coffee has been reported to protect against Parkinson’s disease (PD). Caffeine is an adenosine A2A receptor (encoded by the gene ADORA2A) antagonist that increases dopaminergic neurotransmission and Cytochrome P450 1A2 (gene: CYP1A2) metabolizes caffeine, thus gene polymorphisms in ADORA2A and CYP1A2 may influence the effect coffee consumption has on PD risk. Methods In a population-based case control study (PASIDA) in Denmark (1,556 PD patients and 1,606 birth year- and sex- matched controls), we assessed interactions between lifetime coffee consumption and three polymorphisms in ADORA2A and CYP1A2 for all subjects and incident and prevalent PD cases separately using logistic regression models. We also conducted a meta-analysis combining our results with those from previous studies. Results We estimated statistically significant interactions for ADORA2A rs5760423 and heavy vs. light coffee consumption in incident (OR interaction=0.66 [0.46–0.94], p=0.02) but not prevalent PD. We did not observe interactions for CYP1A2 rs762551 and rs2472304 in incident or prevalent PD. In meta-analyses, PD associations with daily coffee consumption were strongest among carriers of variant alleles in both ADORA2A and CYP1A2. Conclusion We corroborated results from a previous report that described interactions between ADORA2A and CYP1A2 polymorphisms and coffee consumption. Our results also suggest that survivor bias may affect results of studies that enrol prevalent PD cases. PMID:28135712

  20. CYP1A1 and CYP1A2 expression: Comparing 'humanized' mouse lines and wild-type mice; comparing human and mouse hepatoma-derived cell lines

    International Nuclear Information System (INIS)

    Uno, Shigeyuki; Endo, Kaori; Ishida, Yuji; Tateno, Chise; Makishima, Makoto; Yoshizato, Katsutoshi; Nebert, Daniel W.

    2009-01-01

    Human and rodent cytochrome P450 (CYP) enzymes sometimes exhibit striking species-specific differences in substrate preference and rate of metabolism. Human risk assessment of CYP substrates might therefore best be evaluated in the intact mouse by replacing mouse Cyp genes with human CYP orthologs; however, how 'human-like' can human gene expression be expected in mouse tissues? Previously a bacterial-artificial-chromosome-transgenic mouse, carrying the human CYP1A1 C YP1A2 locus and lacking the mouse Cyp1a1 and Cyp1a2 orthologs, was shown to express robustly human dioxin-inducible CYP1A1 and basal versus inducible CYP1A2 (mRNAs, proteins, enzyme activities) in each of nine mouse tissues examined. Chimeric mice carrying humanized liver have also been generated, by transplanting human hepatocytes into a urokinase-type plasminogen activator(+/+) s evere-combined-immunodeficiency (uPA/SCID) line with most of its mouse hepatocytes ablated. Herein we compare basal and dioxin-induced CYP1A mRNA copy numbers, protein levels, and four enzymes (benzo[a]pyrene hydroxylase, ethoxyresorufin O-deethylase, acetanilide 4-hydroxylase, methoxyresorufin O-demethylase) in liver of these two humanized mouse lines versus wild-type mice; we also compare these same parameters in mouse Hepa-1c1c7 and human HepG2 hepatoma-derived established cell lines. Most strikingly, mouse liver CYP1A1-specific enzyme activities are between 38- and 170-fold higher than human CYP1A1-specific enzyme activities (per unit of mRNA), whereas mouse versus human CYP1A2 enzyme activities (per unit of mRNA) are within 2.5-fold of one another. Moreover, both the mouse and human hepatoma cell lines exhibit striking differences in CYP1A mRNA levels and enzyme activities. These findings are relevant to risk assessment involving human CYP1A1 and CYP1A2 substrates, when administered to mice as environmental toxicants or drugs.

  1. Glutathione S-transferase M1 and T1, CYP1A2-2467T/delT ...

    African Journals Online (AJOL)

    The present study investigated the impact of metabolic gene polymorphisms in modulating lung cancer risk susceptibility. Gene polymorphisms encoding Cytochrome 1A2 (CYP1A2) and Glutathione-S-transferases (GSTT1 and GSTM1) are involved in the bioactivation and detoxification of tobacco carcinogens and may ...

  2. Sequencing and characterization of mixed function monooxygenase genes CYP1A1 and CYP1A2 of Mink (Mustela vison) to facilitate study of dioxin-like compounds

    International Nuclear Information System (INIS)

    Zhang Xiaowei; Moore, Jeremy N.; Newsted, John L.; Hecker, Markus; Zwiernik, Matthew J.; Jones, Paul D.; Bursian, Steven J.

    2009-01-01

    As part of an ongoing effort to understand aryl hydrocarbon receptor (AhR) mediated toxicity in mink, cDNAs encoding for CYP1A1 and the CYP1A2 mixed function monooxygenases were cloned and characterized. In addition, the effects of selected dibenzofurans on the expression of these genes and the presence of their respective proteins (P4501A) were investigated, and then correlated with the catalytic activities of these proteins as measured by ethoxyresorufin O-deethylase (EROD) and methoxyresorufin O-deethylase (MROD) activities. The predicted protein sequences for CYP1A1 and CYP1A2 comprise 517 and 512 amino acid residues, respectively. The phylogenetic analysis of the mink CYP1As with protein sequences of other mammals revealed high sequence homology with sea otter, seals and the dog, with amino acid identities ranging from 89 to 95% for CYP1A1 and 81 to 93% for CYP1A2. Since exposure to both 2,3,7,8-Tetrachlorodibenzofuran (TCDF) and 2,3,4,7,8-Pentachlorodibenzofuran (PeCDF) resulted in dose-dependent increases of CYP1A1 mRNA, CYP1A2 mRNA and CYP1A protein levels an underlying AhR-mediated mechanism is suggested. The up-regulation of CYP1A mRNA in liver was more consistent to the sum adipose TEQ concentration than to the liver TEQ concentration in minks treated with TCDF or PeCDF. The result suggested that the hepatic-sequestered fraction of PeCDF was biologically inactive to the induction of CYP1A1 and CYP1A2

  3. Water pipe (Shisha, Hookah, Arghile) Smoking and Secondhand Tobacco Smoke Effects on CYP1A2 and CYP2A6 Phenotypes as Measured by Caffeine Urine Test.

    Science.gov (United States)

    Yılmaz, Şenay Görücü; Llerena, Adrián; De Andrés, Fernando; Karakaş, Ümit; Gündoğar, Hasan; Erciyas, Kamile; Kimyon, Sabit; Mete, Alper; Güngör, Kıvanç; Özdemir, Vural

    2017-03-01

    Public policies to stop or reduce cigarette smoking and exposure to secondhand smoke and associated diseases have yielded successful results over the past decade. Yet, the growing worldwide popularity of another form of tobacco consumption, water pipe smoking, has received relatively less attention. To the best of our knowledge, no study to date has evaluated the effects of water pipe smoking on cytochrome P450 (CYP450) activities and drug interaction potential in humans, whereas only limited information is available on the impact of secondhand smoke on drug metabolism. In a sample of 99 healthy volunteers (28 water pipe smokers, 30 secondhand tobacco smoke exposed persons, and 41 controls), we systematically compared CYP1A2 and CYP2A6 enzyme activities in vivo using caffeine urine test. The median self-reported duration of water pipe smoking was 7.5 h/week and 3 years of exposure in total. The secondhand smoke group had a median of 14 h of self-reported weekly exposure to tobacco smoke indoor where a minimum of five cigarettes were smoked/hour for a total of 3.5 years (median). Analysis of variance did not find a significant difference in CYP1A2 and CYP2A6 activities among the three study groups (p > 0.05). Nor was there a significant association between the extent of water pipe or secondhand smoke exposure and the CYP1A2 and CYP2A6 activities (p > 0.05). Further analysis in a subsample with smoke exposure more than the median values also did not reveal a significant difference from the controls. Although we do not rule out an appreciable possible impact of water pipe smoke and secondhand smoke on in vivo activities of these two drug metabolism pathways, variability in smoke constituents from different tobacco consumption methods (e.g., water pipe) might affect drug metabolism in ways that might differ from that of cigarette smoke. Further studies in larger prospective samples are recommended to evaluate water pipe and secondhand tobacco smoke effects

  4. The CYP1A2 -163C>A polymorphism does not alter the effects of caffeine on basketball performance.

    Science.gov (United States)

    Puente, Carlos; Abián-Vicén, Javier; Del Coso, Juan; Lara, Beatriz; Salinero, Juan José

    2018-01-01

    The aim of this investigation was to analyze the influence of the genetic variations of the -163C>A polymorphism of the CYP1A2 gene on the ergogenic effects of caffeine in elite basketball players. Nineteen elite basketball players (10 men and 9 women) ingested 3 mg⋅kg-1 of caffeine or a placebo 60 min before performing 10 repetitions of the following series: the Abalakov jump test followed by the Change-of-Direction and Acceleration Test (CODAT). The players then competed in a 20-min simulated basketball game. Self-perceived performance and side effects were recorded by questionnaires after the trials. The effects of caffeine on basketball performance were established according to players' CYP1A2 genotype (rs762551): AA homozygotes (n = 10) and C-allele carriers (n = 9). In the 10 repetitions, caffeine increased Abalakov jump height by a mean of 2.9±3.6% in AA homozygotes (p = 0.03) while this effect did not reach statistical significance for C-allele carriers (2.3 ± 6.8%; p = 0.33). Caffeine did not affect sprint time in the CODAT test in either genotype group but it increased the number of impacts performed during the simulated game in both AA homozygotes (4.1 ± 5.3%; p = 0.02) and C-allele carriers (3.3 ± 3.2%; p = 0.01). During the 24 h following the test, AA homozygotes tended to experience increased insomnia with caffeine while C-allele carriers did not present this effect. The remaining variables were unaffected by the genotype. The CYP1A2 -163C>A polymorphism minimally altered the ergogenicity derived from the consumption of a moderate dose of caffeine in elite basketball players.

  5. The CYP1A2 -163C>A polymorphism does not alter the effects of caffeine on basketball performance

    Science.gov (United States)

    Puente, Carlos; Abián-Vicén, Javier; Lara, Beatriz; Salinero, Juan José

    2018-01-01

    Purpose The aim of this investigation was to analyze the influence of the genetic variations of the -163C>A polymorphism of the CYP1A2 gene on the ergogenic effects of caffeine in elite basketball players. Methods Nineteen elite basketball players (10 men and 9 women) ingested 3 mg⋅kg-1 of caffeine or a placebo 60 min before performing 10 repetitions of the following series: the Abalakov jump test followed by the Change-of-Direction and Acceleration Test (CODAT). The players then competed in a 20-min simulated basketball game. Self-perceived performance and side effects were recorded by questionnaires after the trials. The effects of caffeine on basketball performance were established according to players’ CYP1A2 genotype (rs762551): AA homozygotes (n = 10) and C-allele carriers (n = 9). Results In the 10 repetitions, caffeine increased Abalakov jump height by a mean of 2.9±3.6% in AA homozygotes (p = 0.03) while this effect did not reach statistical significance for C-allele carriers (2.3 ± 6.8%; p = 0.33). Caffeine did not affect sprint time in the CODAT test in either genotype group but it increased the number of impacts performed during the simulated game in both AA homozygotes (4.1 ± 5.3%; p = 0.02) and C-allele carriers (3.3 ± 3.2%; p = 0.01). During the 24 h following the test, AA homozygotes tended to experience increased insomnia with caffeine while C-allele carriers did not present this effect. The remaining variables were unaffected by the genotype. Conclusion The CYP1A2 -163C>A polymorphism minimally altered the ergogenicity derived from the consumption of a moderate dose of caffeine in elite basketball players. PMID:29668752

  6. The interindividual differences in the 3-demthylation of caffeine alias CYP1A2 is determined by both genetic and environmental factors

    DEFF Research Database (Denmark)

    Rasmussen, Birgitte B; Brix, Thomas H; Kyvik, Kirsten O

    2002-01-01

    . The mean (+/- SD) caffeine ratio was 5.9 +/- 3.4. The caffeine ratio was statistically significantly higher in men compared to women, in smoking men and women compared to non-smoking persons of the same gender and in women not taking oral contraceptives compared with women on oral contraceptives. Thus, we...... confirmed that CYP1A2 is more active in men than in women, that it is induced by smoking and inhibited by oral contraceptives. In the subsequent analysis of heritability, we included 49 monozygotic twin pairs and 34 same gender dizygotic twin pairs concordant for non-smoking and non-use of oral...... contraceptives. The intraclass correlation coefficient was 0.798 (95% confidence interval, 0.696-0.900) and 0.394 (95% confidence interval, 0.109-0.680) in the monozygotic and dizygotic twins, respectively. The correlation was statistically significantly higher (P = 0.0015) in the former compared with the latter...

  7. ANTIBODIES TO BENZO[A]PYRENE AND POLYMORPHISMS OF CYP1A1*2A, CYP1A2*1F, GSTT1, AND GSTM1 GENES IN HEALTHY MEN AND LUNG CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    A. N. Glushkov

    2016-01-01

    Full Text Available Some genetic polymorphisms of CYP and GST enzymes metabolizing low-molecular weight xenobiotics may represent endogenous risk factors for carcinogenesis. However, possible relationships between the enzyme activities, amounts of carcinogen adducts and synthesis of anticarcinogen antibodies in humans (including cancer patients are still poorly studied. The purpose of this study was to identify possible associations between occurrence of antibodies against benzo[a]pyrene, and frequency of genetic polymorphisms of CYP1A1*2A, CYP1A2*1F, GSTT1, GSTM1 in healthy men and in lung cancer patients. Materials and methods. We have examined 203 men with non-small cell lung cancer and 267 apparently healthy donors without respiratory diseases. A non-competitive solid phase immunoassay of antibodies to benzo[a]pyrene was performed. Analysis of polymorphic loci within CYP1A1 (rs4646903, CYP1A2 (rs762551, GSTP1 (rs1695, rs1138272 was performed by means of real-time PCR using TaqMan technology. Null-alleles of GSTM1 (del, GSTT1 (del genes were detected by multiplex PCR with real-time fluorescent assay. Results. Among the lung cancer patients, the proportion of cases with a high level of IgG antibodies to benzo[a]pyrene in carriers of GSTT1+ and GSTM1+ in conjunction with the CYP1A2*1F C allele was significantly greater than in AA homozygotes CYP1A2*1F. The risk of lung cancer was increased to 5.5 in carriers of CYP1A2*1F C allele combined with GSTT1+ and GSTM1+ at high levels of IgG antibodies to benzo [a] pyrene. In healthy male donors, we have not found differences between the incidence of low and high levels of IgG anti-benzo[a]pyrene antibodies in the carriers of certain CYP1A1*2A, CYP1A2*1F, GSTT1 and GSTM1 genotypes. Conclusions. We have first reported a relationship between CYP1 and GST gene polymorphisms and specific immune response to chemical carcinogens in lung cancer patients. Immunoassays of IgG antibodies to benzo[a]pyrene combined with molecular

  8. Genome-wide meta-analysis identifies regions on 7p21 (AHR and 15q24 (CYP1A2 as determinants of habitual caffeine consumption.

    Directory of Open Access Journals (Sweden)

    Marilyn C Cornelis

    2011-04-01

    Full Text Available We report the first genome-wide association study of habitual caffeine intake. We included 47,341 individuals of European descent based on five population-based studies within the United States. In a meta-analysis adjusted for age, sex, smoking, and eigenvectors of population variation, two loci achieved genome-wide significance: 7p21 (P = 2.4 × 10(-19, near AHR, and 15q24 (P = 5.2 × 10(-14, between CYP1A1 and CYP1A2. Both the AHR and CYP1A2 genes are biologically plausible candidates as CYP1A2 metabolizes caffeine and AHR regulates CYP1A2.

  9. Paracetamol-induced spindle disturbances in V79 cells with and without expression of human CYP1A2

    DEFF Research Database (Denmark)

    Jensen, K G; Poulsen, H E; Doehmer, J

    1996-01-01

    Spindle disturbing effects in terms of c-mitosis and cytotoxicity of paracetamol were investigated in two Chinese hamster V79 cell lines, one of which (V79MZh1A2) was transfected with human CYP1A2. This enzyme catalyses the oxidative formation of the reactive paracetamol metabolite, NAPQI, believed...... to initiate hepatoxicity by covalent binding to proteins after overdose. In the native V79 cell line paracetamol increased c-mitosis frequency in a concentration dependent manner from 8.7 + or - 3.5% (control) to 66 + or - 18% at 20 mM. A significant increase to 13.3 + or - 3.5% was first seen at 2.5 m......M in the native cell line (Pparacetamol. At 5 mM paracetamol the c-mitosis frequency was 14.4 + or - 5.0% and 19.0 + or - 3...

  10. SNP genetic polymorphisms of MDR-1, CYP1A2 and CYPB11 genes in four canine breeds upon toxicological evaluation.

    Science.gov (United States)

    Gagliardi, Rosa; Llambí, Silvia; Arruga, M Victoria

    2015-01-01

    The fields of pharmacogenetics and pharmacogenomics have become increasingly promising regarding the clinical application of genetic data to aid in prevention of adverse reactions. Specific screening tests can predict which animals express modified proteins or genetic sequences responsible for adverse effects associated with a drug. Among the genetic variations that have been investigated in dogs, the multidrug resistance gene (MDR) is the best studied. However, other genes such as CYP1A2 and CYP2B11 control the protein syntheses involved in the metabolism of many drugs. In the present study, the MDR-1, CYP1A2 and CYP2B11 genes were examined to identify SNP polymorphisms associated with these genes in the following four canine breeds: Uruguayan Cimarron, Border Collie, Labrador Retriever and German Shepherd. The results revealed that several SNPs of the CYP1A2 and CYP2B11 genes are potential targets for drug sensitivity investigations.

  11. Dose-dependent inhibition of CYP1A2, CYP2C19 and CYP2D6 by citalopram, fluoxetine, fluvoxamine and paroxetine

    DEFF Research Database (Denmark)

    Jeppesen, U; Gram, L F; Vistisen, K

    1996-01-01

    OBJECTIVE: The purpose of this pharmacokinetic study was to investigate the dose-dependent inhibition of model substrates for CYP2D6, CYP2C19 and CYP1A2 by four marketed selective serotonin reuptake inhibitors (SSRIs): citalopram, fluoxetine, fluvoxamine and paroxetine. METHODS: The study...

  12. Characterization CYP1A2, CYP2C9, CYP2C19 and CYP2D6 polymorphisms using HRMA in Psychiatry patients with schizophrenia and bipolar disease for personalized medicine.

    Science.gov (United States)

    Yenilmez, Ebru Dundar; Tamam, Lut; Karaytug, Onur; Tuli, Abdullah

    2018-06-19

    The interindividual genetic variations in drug metabolizing enzymes effects the impact and toxicity in plenty of drugs. The CYP1A2, CYP2C9, CYP2C19 and CYP2D6 gene polymorphisms characterized using high resolution melting analysis (HRMA) in follow-up patients in psychiatry clinic as a preliminary preparation for personalized medicine. Genotyping of CYP1A2*1F, CYP2C9 *2, *3, CYP2C19 *2, *3 and *17 and CYP2D6 *3, *4 was conducted in 101 patients using HRMA. Genotype and allele frequencies of the CYP variants were found to be in equilibrium with the Hardy-Weinberg equation. The frequency of the CYP1A2*1F allele in schizophrenia and bipolar disease was 0.694 and 0.255, respectively. The CYP2C9 allele frequencies were 0.087 (CYP2C9*2), and 0.549 (CYP2C9*3) for bipolar; 0.278 (CYP2C9*2) and 0.648 (CYP2C9*3) in schizophrenias. The CYP2C19*2 and *17 allele frequencies was 0.111 and 0.185 in schizophrenia and variant *2 was 0.117 and variant *17 was 0.255 in bipolar group. The frequency of the CYP2D6*3 allele was 0.027 in schizophrenias. The frequencies for the CYP2D6*4 variant was 0.092 and 0.096 in schizophrenia and bipolar groups, respectively. The knowledge in pharmacogenomics and also the developments in molecular genetics are growing rapidly. In the future this can be expected to provide new methodologies in the prediction of the activity in drug metabolizing enzymes. The HRMA is a rapid and useful technique to identify the genotypes for drug dosage adjustment before therapy in psychiatry patients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. CYP1A2 – a novel genetic marker for early aromatase inhibitor response in the treatment of breast cancer patients

    International Nuclear Information System (INIS)

    Simonsson, Maria; Veerla, Srinivas; Markkula, Andrea; Rose, Carsten; Ingvar, Christian; Jernström, Helena

    2016-01-01

    Endocrine resistance is a major obstacle to optimal treatment effect in breast cancer. Some genetic markers have been proposed to predict response to aromatase inhibitors (AIs) but the data is insufficient. The aim of the study was to find new genetic treatment predictive markers of AIs. The ongoing population-based BC-blood study in Lund, Sweden includes women with primary breast cancer. This paper is based on AI-treated patients with estrogen receptor positive tumors who underwent breast cancer surgery in 2002–2008. First, an exploratory analysis of 1931 SNPs in 227 genes involved in absorption, distribution, metabolism, and elimination of multiple medications, using DMET™ chips, was conducted in a subset of the cohort with last follow-up in December 31 st 2011 (13 cases, 11 controls). Second, selected SNPs from the first analysis were re-analyzed concerning risk for early breast cancer events in the extended cohort of 201 AI-treated with last follow-up in June 30 th 2014. Clinical data were obtained from medical records and population registries. Only CYP1A2 rs762551 C-allele was significantly associated with increased risk for early events in the 24 patients (P = 0.0007) and in the extended cohort, adjusted Hazard ratio (HR) 2.22 (95 % CI 1.03–4.80). However, the main prognostic impact was found within five years, adjusted HR 7.88 (95 % CI 2.13–29.19). The impact of the CYP1A2 rs762551 C-allele was modified by a functional polymorphism in the regulator gene AhR Arg554Lys (G > A). Compared to patients who were homozygous for the major allele in both genes (CYP1A2 A/A and AhR G/G), a 9-fold risk for early events was found in patients who had at least one minor allele in both genes, adjusted HR 8.95 (95 % CI 2.55–31.35), whereas patients with at least one minor allele in either but not both genes had a 3-fold risk for early events, adjusted HR 2.81 (95 % CI 1.07–7.33). The impact of CYP1A2 rs762551 C-allele was also modified by the CYP19A1 rs4646 C

  14. CYP1A1, CYP1A2, SULT1A1 AND SULT1E1 ALLELIC POLYMORPHISM IN CASE OF GENITAL ENDOMETRIOSIS

    Directory of Open Access Journals (Sweden)

    Konstantin Sergeevich Kublinskiy

    2016-02-01

    Up-to-date molecular and genetic analyses reveal that women predisposed to genital endometriosis possess Allele G and Genotypes AG and GG of the polymorphic option A-4889G of the CYP1A1 gene and Allele A and Genotypes CA and AA of the polymorphic option C-734A of the CYP1A2 gene. The polymorphism of the promoter regions of the SULT1A1 (G-638A and SULT1E1 (C-174T genes is not associated with genital endometriosis in women.

  15. CYP1A2 rs762551 polymorphism contributes to cancer susceptibility: a meta-analysis from 19 case-control studies

    Directory of Open Access Journals (Sweden)

    Wang Hongge

    2012-11-01

    Full Text Available Abstract Background Genetic polymorphism (rs762551A>C in gene encoding cytochrome P450 1A2 (CYP1A2 has been shown to influence the inducibility of CYP1A2 expression and thus might be associated with risk of several types of human cancer. However, the results of previous studies on the associations of this polymorphism with risk of cancer are not all consistent. To clarify the potential contribution of CYP1A2 rs762551 to cancer risk, we performed a meta-analysis of the published case–control studies. Methods We used PubMed, Embase, OVID, ScienceDirect, and Chinese National Knowledge Infrastructure databases to identify the related publications for this meta-analysis. The pooled odds ratio (OR and 95% confidence interval (CI were calculated using random effect model to evaluate the association of rs762551 with cancer risk. A χ2-based Q-test was used to examine the heterogeneity assumption and the funnel plot and Egger’s test were used to examine the potential publication bias. The leave-one-out sensitivity analysis was conducted to determine whether our assumptions or decisions have a major effect on the results of the review. Results Our analysis of 19 eligible case–control studies showed a significant association between rs762551C variant with risk of cancer in the genetic model of CC versus AA (OR = 1.30, 95% CI = 1.02-1.64 and the dominant model (OR = 1.19, 95% CI = 1.04-1.36. In subgroup analysis based on ethnicity, the rs762551CC genotype was associated with increased cancer risk (OR = 1.29, 95% CI = 1.27-1.63 in co-dominate model and OR = 1.17, 95% CI = 1.02-1.34 in dominant model in Caucasians, but not in Asians and the mixed population. Conclusion These results suggested that CYP1A2 rs762551 polymorphism is likely to be associated with susceptibility to cancer in Caucasians.

  16. Minimization of annotation work: diagnosis of mammographic masses via active learning

    Science.gov (United States)

    Zhao, Yu; Zhang, Jingyang; Xie, Hongzhi; Zhang, Shuyang; Gu, Lixu

    2018-06-01

    The prerequisite for establishing an effective prediction system for mammographic diagnosis is the annotation of each mammographic image. The manual annotation work is time-consuming and laborious, which becomes a great hindrance for researchers. In this article, we propose a novel active learning algorithm that can adequately address this problem, leading to the minimization of the labeling costs on the premise of guaranteed performance. Our proposed method is different from the existing active learning methods designed for the general problem as it is specifically designed for mammographic images. Through its modified discriminant functions and improved sample query criteria, the proposed method can fully utilize the pairing of mammographic images and select the most valuable images from both the mediolateral and craniocaudal views. Moreover, in order to extend active learning to the ordinal regression problem, which has no precedent in existing studies, but is essential for mammographic diagnosis (mammographic diagnosis is not only a classification task, but also an ordinal regression task for predicting an ordinal variable, viz. the malignancy risk of lesions), multiple sample query criteria need to be taken into consideration simultaneously. We formulate it as a criteria integration problem and further present an algorithm based on self-adaptive weighted rank aggregation to achieve a good solution. The efficacy of the proposed method was demonstrated on thousands of mammographic images from the digital database for screening mammography. The labeling costs of obtaining optimal performance in the classification and ordinal regression task respectively fell to 33.8 and 19.8 percent of their original costs. The proposed method also generated 1228 wins, 369 ties and 47 losses for the classification task, and 1933 wins, 258 ties and 185 losses for the ordinal regression task compared to the other state-of-the-art active learning algorithms. By taking the

  17. CYP1A2 and NAT2 phenotyping and 3-aminobiphenyl and 4-aminobiphenyl hemoglobin adduct levels in smokers and non-smokers

    International Nuclear Information System (INIS)

    Sarkar, Mohamadi; Stabbert, Regina; Kinser, Robin D.; Oey, Jan; Rustemeier, Klaus; Holt, Klaus von; Schepers, Georg; Walk, Roger A.; Roethig, Hans J.

    2006-01-01

    Some aromatic amines are considered to be putative bladder carcinogens. Hemoglobin (Hb) adducts of 3-aminobiphenyl (3-ABP) and 4-aminobiphenyl (4-ABP) have been used as biomarkers of exposure to aromatic amines from cigarette smoke. One of the goals of this study was to determine intra- and inter-individual variability in 3-ABP and 4-ABP Hb adducts and to explore the predictability of ABP Hb adduct levels based on caffeine phenotyping. The study was conducted in adult smokers (S, n = 65) and non-smokers (NS, n 65). The subjects were phenotyped for CYP1A2 and NAT2 using urinary caffeine metabolites. Blood samples were collected twice within 6 weeks and adducts measured by GC/MS. The levels of 4-ABP Hb adducts were significantly (p < 0.0001) greater in S (34.5 ± 21.06 pg/g Hb) compared to NS (6.3 ± 3.02 pg/g Hb). The levels of 3-ABP Hb adducts were below the limit of quantification (BLOQ) in most (82%) of the NS and about 10-fold lower in S (3.6 ± 3.29 pg/g Hb) compared to 4-ABP Hb adducts. No differences were observed in the adduct levels between weeks 1 and 6 in the smokers, suggesting that a single sample would be adequate to monitor cigarette smoke exposure. The regression model developed with CYP1A2, NAT2 phenotype and number of cigarettes smoked (NCIG) accounted for 47% of the variability in 3-ABP adducts, whereas 32% variability in 4-ABP adducts was accounted by CYP1A2 and NCIG. The ratio of 4-ABP Hb adducts in adult S:NS was ∼ 5:1, whereas 3-ABP Hb adducts levels were BLOQ in some S, exhibited large interindividual variability (∼ 91% compared to 57% for 4-ABP Hb) and poor dose response relationship. Therefore, 4-ABP Hb adduct levels may be a more useful biomarker of aminobiphenyl exposure from cigarette smoke

  18. Caffeine intake and abstract reasoning among 1374 unselected men and women from general population. Role of the -163C>A polymorphism of CYP1A2 gene.

    Science.gov (United States)

    Casiglia, Edoardo; Tikhonoff, Valérie; Albertini, Federica; Favaro, Jacopo; Montagnana, Martina; Danese, Elisa; Finatti, Francesco; Benati, Marco; Mazza, Alberto; Dal Maso, Lucia; Spinella, Paolo; Palatini, Paolo

    2017-08-01

    The possible effect of caffeine as an enhancer of cognitive performance, particularly that on abstract reasoning, has never been studied in an epidemiological setting, especially in relation to -163C>A polymorphism of CYP1A2 gene, largely controlling caffeine metabolism. Aim of this study was to ascertain whether in general population free chronic caffeine intake modifies abstract reasoning, and if this effect is influenced by the above mentioned genotype, by age, schooling, ethanol intake and smoking habits. We studied 1374 unselected men and women aged 51 ± 15 years (range 18-89) from a general population. Daily caffeine intake deriving from coffee, tea, chocolate or cola was calculated from an anamnestic questionnaire and from a 7-day dietary diary. Abstract reasoning was measured in the frame of a neuropsychological assessment as the ability to find a concept linking two words indicating objects or actions and explaining how they were connected. In age-schooling-adjusted linear regression, the higher the caffeine intake, the better the abstraction score. Abstract reasoning depended on caffeine in the -163C>A CC homozygous only (so-called slow metabolizers), where it was higher in the 3rd tertile of caffeine intake. Age and ethanol reduced while smoking and schooling enhanced this association. The interaction term between caffeine and the -163C>A polymorphism was accepted in linear regressions. Caffeine consumption resulted innocuous for the A-carriers (so-called fast metabolizers). In general population, a positive association between caffeine intake and abstract reasoning exists in the CC homozygous of the -163C>A polymorphism of CYP1A2 gene. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  19. Coffee consumption and CYP1A2 genotype in relation to bone mineral density of the proximal femur in elderly men and women: a cohort study

    Directory of Open Access Journals (Sweden)

    Lind Lars

    2010-02-01

    Full Text Available Abstract Background Drinking coffee has been linked to reduced calcium conservation, but it is less clear whether it leads to sustained bone mineral loss and if individual predisposition for caffeine metabolism might be important in this context. Therefore, the relation between consumption of coffee and bone mineral density (BMD at the proximal femur in men and women was studied, taking into account, for the first time, genotypes for cytochrome P450 1A2 (CYP1A2 associated with metabolism of caffeine. Methods Dietary intakes of 359 men and 358 women (aged 72 years, participants of the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS, were assessed by a 7-day food diary. Two years later, BMD for total proximal femur, femoral neck and trochanteric regions of the proximal femur were measured by Dual-energy X-ray absorptiometry (DXA. Genotypes of CYP1A2 were determined. Adjusted means of BMD for each category of coffee consumption were calculated. Results Men consuming 4 cups of coffee or more per day had 4% lower BMD at the proximal femur (p = 0.04 compared with low or non-consumers of coffee. This difference was not observed in women. In high consumers of coffee, those with rapid metabolism of caffeine (C/C genotype had lower BMD at the femoral neck (p = 0.01 and at the trochanter (p = 0.03 than slow metabolizers (T/T and C/T genotypes. Calcium intake did not modify the relation between coffee and BMD. Conclusion High consumption of coffee seems to contribute to a reduction in BMD of the proximal femur in elderly men, but not in women. BMD was lower in high consumers of coffee with rapid metabolism of caffeine, suggesting that rapid metabolizers of caffeine may constitute a risk group for bone loss induced by coffee.

  20. Genome-wide association analysis of coffee drinking suggests association with CYP1A1/CYP1A2 and NRCAM.

    Science.gov (United States)

    Amin, N; Byrne, E; Johnson, J; Chenevix-Trench, G; Walter, S; Nolte, I M; Vink, J M; Rawal, R; Mangino, M; Teumer, A; Keers, J C; Verwoert, G; Baumeister, S; Biffar, R; Petersmann, A; Dahmen, N; Doering, A; Isaacs, A; Broer, L; Wray, N R; Montgomery, G W; Levy, D; Psaty, B M; Gudnason, V; Chakravarti, A; Sulem, P; Gudbjartsson, D F; Kiemeney, L A; Thorsteinsdottir, U; Stefansson, K; van Rooij, F J A; Aulchenko, Y S; Hottenga, J J; Rivadeneira, F R; Hofman, A; Uitterlinden, A G; Hammond, C J; Shin, S-Y; Ikram, A; Witteman, J C M; Janssens, A C J W; Snieder, H; Tiemeier, H; Wolfenbuttel, B H R; Oostra, B A; Heath, A C; Wichmann, E; Spector, T D; Grabe, H J; Boomsma, D I; Martin, N G; van Duijn, C M

    2012-11-01

    Coffee consumption is a model for addictive behavior. We performed a meta-analysis of genome-wide association studies (GWASs) on coffee intake from 8 Caucasian cohorts (N=18 176) and sought replication of our top findings in a further 7929 individuals. We also performed a gene expression analysis treating different cell lines with caffeine. Genome-wide significant association was observed for two single-nucleotide polymorphisms (SNPs) in the 15q24 region. The two SNPs rs2470893 and rs2472297 (P-values=1.6 × 10(-11) and 2.7 × 10(-11)), which were also in strong linkage disequilibrium (r(2)=0.7) with each other, lie in the 23-kb long commonly shared 5' flanking region between CYP1A1 and CYP1A2 genes. CYP1A1 was found to be downregulated in lymphoblastoid cell lines treated with caffeine. CYP1A1 is known to metabolize polycyclic aromatic hydrocarbons, which are important constituents of coffee, whereas CYP1A2 is involved in the primary metabolism of caffeine. Significant evidence of association was also detected at rs382140 (P-value=3.9 × 10(-09)) near NRCAM-a gene implicated in vulnerability to addiction, and at another independent hit rs6495122 (P-value=7.1 × 10(-09))-an SNP associated with blood pressure-in the 15q24 region near the gene ULK3, in the meta-analysis of discovery and replication cohorts. Our results from GWASs and expression analysis also strongly implicate CAB39L in coffee drinking. Pathway analysis of differentially expressed genes revealed significantly enriched ubiquitin proteasome (P-value=2.2 × 10(-05)) and Parkinson's disease pathways (P-value=3.6 × 10(-05)).

  1. Caffeine raises the serum melatonin level in healthy subjects: an indication of melatonin metabolism by cytochrome P450(CYP)1A2.

    Science.gov (United States)

    Ursing, C; Wikner, J; Brismar, K; Röjdmark, S

    2003-05-01

    Caffeine is metabolized in the liver by cytochrome P450(CYP)1A2. Recent findings imply that this enzyme may also be of importance for the metabolism of human melatonin (MT). If caffeine and MT are metabolized by the same enzyme, one may expect to find different serum MT levels after ingestion of coffee compared with placebo. Although coffee is consumed by people all over the world, few studies have focused on whether caffeine actually affects serum MT levels in normal subjects. We decided to study that particular topic. For that purpose 12 healthy individuals were tested on two occasions, one week apart. On one of these occasions they were given a capsule containing 200 mg caffeine in the evening. On the other, they received placebo. The experimental order was randomized. Serum MT levels were determined every second hour between 22:00 h and 08:00 h, and the melatonin areas under the curve (MT-AUCs) were calculated. After caffeine the serum MT level rose from 0.09 +/- 0.03 nmol/l at 22:00 h to 0.48 +/- 0.07 nmol/l at 04:00 h. The corresponding rise after placebo was less prominent (from 0.06 +/- 0.01 to 0.35 +/- 0.06 nmol/l). This was reflected by the MT-AUC which was 32% larger after ingestion of caffeine compared with placebo (MT-AUC(caffeine) 3.16 +/- 0.44 nmol/l x h vs MT-AUC(placebo) 2.39 +/- 0.40 nmol/l x h; p coffee, augments the nocturnal serum MT level, which in turn supports the notion that cytochrome P450(CYP)1A2 is involved in the hepatic metabolism of human MT.

  2. Coffee consumption and CYP1A2 genotype in relation to bone mineral density of the proximal femur in elderly men and women: a cohort study.

    Science.gov (United States)

    Hallström, Helena; Melhus, Håkan; Glynn, Anders; Lind, Lars; Syvänen, Ann-Christine; Michaëlsson, Karl

    2010-02-22

    Drinking coffee has been linked to reduced calcium conservation, but it is less clear whether it leads to sustained bone mineral loss and if individual predisposition for caffeine metabolism might be important in this context. Therefore, the relation between consumption of coffee and bone mineral density (BMD) at the proximal femur in men and women was studied, taking into account, for the first time, genotypes for cytochrome P450 1A2 (CYP1A2) associated with metabolism of caffeine. Dietary intakes of 359 men and 358 women (aged 72 years), participants of the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS), were assessed by a 7-day food diary. Two years later, BMD for total proximal femur, femoral neck and trochanteric regions of the proximal femur were measured by Dual-energy X-ray absorptiometry (DXA). Genotypes of CYP1A2 were determined. Adjusted means of BMD for each category of coffee consumption were calculated. Men consuming 4 cups of coffee or more per day had 4% lower BMD at the proximal femur (p = 0.04) compared with low or non-consumers of coffee. This difference was not observed in women. In high consumers of coffee, those with rapid metabolism of caffeine (C/C genotype) had lower BMD at the femoral neck (p = 0.01) and at the trochanter (p = 0.03) than slow metabolizers (T/T and C/T genotypes). Calcium intake did not modify the relation between coffee and BMD. High consumption of coffee seems to contribute to a reduction in BMD of the proximal femur in elderly men, but not in women. BMD was lower in high consumers of coffee with rapid metabolism of caffeine, suggesting that rapid metabolizers of caffeine may constitute a risk group for bone loss induced by coffee.

  3. Background risk of breast cancer and the association between physical activity and mammographic density.

    Science.gov (United States)

    Trinh, Thang; Eriksson, Mikael; Darabi, Hatef; Bonn, Stephanie E; Brand, Judith S; Cuzick, Jack; Czene, Kamila; Sjölander, Arvid; Bälter, Katarina; Hall, Per

    2015-04-02

    High physical activity has been shown to decrease the risk of breast cancer, potentially by a mechanism that also reduces mammographic density. We tested the hypothesis that the risk of developing breast cancer in the next 10 years according to the Tyrer-Cuzick prediction model influences the association between physical activity and mammographic density. We conducted a population-based cross-sectional study of 38,913 Swedish women aged 40-74 years. Physical activity was assessed using the validated web-questionnaire Active-Q and mammographic density was measured by the fully automated volumetric Volpara method. The 10-year risk of breast cancer was estimated using the Tyrer-Cuzick (TC) prediction model. Linear regression analyses were performed to assess the association between physical activity and volumetric mammographic density and the potential interaction with the TC breast cancer risk. Overall, high physical activity was associated with lower absolute dense volume. As compared to women with the lowest total activity level (association was seen for any type of physical activity among women with association between total activity and absolute dense volume was modified by the TC breast cancer risk (P interaction = 0.05). As anticipated, high physical activity was also associated with lower non-dense volume. No consistent association was found between physical activity and percent dense volume. Our results suggest that physical activity may decrease breast cancer risk through reducing mammographic density, and that the physical activity needed to reduce mammographic density may depend on background risk of breast cancer.

  4. A drug-drug interaction study to assess the effect of the CYP1A2 inhibitor fluvoxamine on the pharmacokinetics of dovitinib (TKI258) in patients with advanced solid tumors

    NARCIS (Netherlands)

    de Weger, Vincent A; Goel, Sanjay; von Moos, Roger; Schellens, Jan H M; Mach, Nicholas; Tan, Eugene; Anand, Suraj; Scott, Jeffrey W; Lassen, Ulrik N

    PURPOSE: Dovitinib is an orally available multi tyrosine kinase inhibitor which inhibits VEGFR 1-3, FGFR 1-3, and PDGFR. This study was performed to investigate the potential drug-drug interaction of dovitinib with the CYP1A2 inhibitor fluvoxamine in patients with advanced solid tumors. METHODS:

  5. A drug-drug interaction study to assess the effect of the CYP1A2 inhibitor fluvoxamine on the pharmacokinetics of dovitinib (TKI258) in patients with advanced solid tumors

    DEFF Research Database (Denmark)

    de Weger, Vincent A; Goel, Sanjay; von Moos, Roger

    2018-01-01

    PURPOSE: Dovitinib is an orally available multi tyrosine kinase inhibitor which inhibits VEGFR 1-3, FGFR 1-3, and PDGFR. This study was performed to investigate the potential drug-drug interaction of dovitinib with the CYP1A2 inhibitor fluvoxamine in patients with advanced solid tumors. METHODS: ...

  6. A COMPARISON OF THE METABOLISM OF METHOXYRESORUFIN, ACETANILIDE AND CAFFIENE IN RAT AND HUMAN CYP1A2 SUPERSOMES AND THEIR INHIBITION BY 2, 3, 7, 8-TETRACHLORODIBENZO-P-DIOXIN (TCDD)

    Science.gov (United States)

    A COMPARISON OF THE METABOLISM OF METHOXYRESORUFIN, ACETANILIDE AND CAFFIENE IN RAT AND HUMAN CYP1A2 SUPERSOMES AND THEIR INHIBITION BY 2,3,7,8-TETRACHLORODIBENZO-P-DIOXIN (TCDD). DF Staskal1, DG Ross2, LS Birnbaum2 and MJ DeVito2 1Curriculum In Toxicology, UNC-CH, Chapel Hill ...

  7. Fractal analysis of visual search activity for mass detection during mammographic screening.

    Science.gov (United States)

    Alamudun, Folami; Yoon, Hong-Jun; Hudson, Kathleen B; Morin-Ducote, Garnetta; Hammond, Tracy; Tourassi, Georgia D

    2017-03-01

    The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) from 10 readers (three board certified radiologists and seven Radiology residents), formed the corpus for this study. The fractal dimension of the readers' visual scanning pattern was computed with the Minkowski-Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the complexity of visual scanning pattern when screening for breast cancer. No higher order effects were found to be significant. Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics. © 2017 American Association of Physicists in Medicine.

  8. CYP1A2*1C, CYP2E1*5B, and GSTM1 polymorphisms are predictors of risk and poor outcome in head and neck squamous cell carcinoma patients

    DEFF Research Database (Denmark)

    Olivieri, Eloisa Helena Ribeiro; da Silva, Sabrina Daniela; Mendonça, Fernando Fernandes

    2009-01-01

    is performed by glutathione S-transferases (GSTs). It has been suggested that genetic alterations, such as polymorphisms, play an important role in tumorigenesis and HNSCC progression. The aim of this study was to investigate CYP1A1, CYP1A2, CYP2E1, GSTM1, and GSTT1 polymorphisms as risk factors in HNSCC...... and their association with clinicopathologic data. The patients comprised 153 individuals with HNSCC (cases) and 145 with no current or previous diagnosis of cancer (controls). Genotyping of the single nucleotide polymorphisms (SNPs) of the CYP1A1, CYP1A2, and CYP2E1 genes was performed by PCR-RFLP and the GSTM1...... for determining the parameters associated with tumor progression and poor outcomes in HNSCC....

  9. Polymorphisms in the cytochrome P450 genes CYP1A2, CYP1B1, CYP3A4, CYP3A5, CYP11A1, CYP17A1, CYP19A1 and colorectal cancer risk

    Directory of Open Access Journals (Sweden)

    Withey Laura

    2007-07-01

    Full Text Available Abstract Background Cytochrome P450 (CYP enzymes have the potential to affect colorectal cancer (CRC risk by determining the genotoxic impact of exogenous carcinogens and levels of sex hormones. Methods To investigate if common variants of CYP1A2, CYP1B1, CYP3A4, CYP3A5, CYP11A1, CYP17A1 and CYP19A1 influence CRC risk we genotyped 2,575 CRC cases and 2,707 controls for 20 single nucleotide polymorphisms (SNPs that have not previously been shown to have functional consequence within these genes. Results There was a suggestion of increased risk, albeit insignificant after correction for multiple testing, of CRC for individuals homozygous for CYP1B1 rs162558 and heterozygous for CYP1A2 rs2069522 (odds ratio [OR] = 1.36, 95% confidence interval [CI]: 1.03–1.80 and OR = 1.34, 95% CI: 1.00–1.79 respectively. Conclusion This study provides some support for polymorphic variation in CYP1A2 and CYP1B1 playing a role in CRC susceptibility.

  10. Induction of CYP1A1, CYP1A2, and CYP1B1 mRNAs by nitropolycyclic aromatic hydrocarbons in various human tissue-derived cells: chemical-, cytochrome P450 isoform-, and cell-specific differences

    Energy Technology Data Exchange (ETDEWEB)

    Iwanari, M.; Nakajima, M.; Yokoi, T. [Div. of Drug Metabolism, Kanazawa Univ., Kanazawa (Japan); Kizu, R.; Hayakawa, K. [Lab. of Hygienic Chemistry, Kanazawa Univ., Kanazawa (Japan)

    2002-06-01

    Nitropolycyclic aromatic hydrocarbons (NPAHs) are found in diesel exhaust and ambient air. NPAHs as well as polycyclic aromatic hydrocarbons (PAHs) are known to have mutagenicity, carcinogenicity, and endocrine-disruptive effects. In the present study, the inducibility of the human cytochrome P450-1 (CYP1) family by NPAHs was compared with those produced by their parent PAHs and some reductive metabolites, amino-PAHs. Furthermore, to investigate the differences in the inducibility of the CYP1 family in human tissues, various human tissue-derived cell lines, namely HepG2 (hepatocellular carcinoma), ACHN (renal carcinoma), A549 (lung carcinoma), MCF-7 (breast carcinoma), LS-180 (colon carcinoma), HT-1197 (bladder carcinoma), HeLa (cervix of uterus adenocarcinoma), OMC-3 (ovarian carcinoma), and NEC14 (testis embryonal carcinoma), were treated with NPAHs, PAHs, or amino-PAHs. The mRNA levels of CYP1A1, CYP1A2, and CYP1B1 were determined with reverse transcription-polymerase chain reaction (RT-PCR). The cell lines were classified into two groups: CYP1 inducible cell lines, comprising HepG2, MCF-7, LS-180, and OMC-3 cells, and CYP1 non-inducible cell lines, comprising ACHN, A549, HT-1197, HeLa, and NEC14 cells. In inducible cell lines, the induction profile of chemical specificity was similar for CYP1A1, CYP1A2, and CYP1B1, although the extent of induction differed among the cell lines and for the CYP isoforms. Pyrene, 1-nitropyrene, 1-aminopyrene, 1,3-, 1,6-, and 1,8-dinitropyrenes slightly induced CYP1 mRNAs, but 1,3-dinitropyrene produced a 6-fold induction of CYP1A1 mRNA in MCF-7 cells. 2-Nitrofluoranthene and 3-nitrofluoranthene exhibited stronger inducibility than fluoranthene in the inducible cell lines. 6-Nitrochrysene induced CYP1 mRNAs to the same extent or more potently than chrysene. The induction potencies of 6-nitrobenzo[a]pyrene and 7-nitrobenz[a]anthracene were weaker than those of their parents benzo[a]pyrene and benz[a]anthracene, respectively. This

  11. Metabolic Pathway of Icotinib In Vitro: The Differential Roles of CYP3A4, CYP3A5, and CYP1A2 on Potential Pharmacokinetic Drug-Drug Interaction.

    Science.gov (United States)

    Zhang, TianHong; Zhang, KeRong; Ma, Li; Li, Zheng; Wang, Juan; Zhang, YunXia; Lu, Chuang; Zhu, Mingshe; Zhuang, XiaoMei

    2018-04-01

    Icotinib is the first self-developed small molecule drug in China for targeted therapy of non-small cell lung cancer. To date, systematic studies on the pharmacokinetic drug-drug interaction of icotinib were limited. By identifying metabolite generated in human liver microsomes and revealing the contributions of major cytochromes P450 (CYPs) in the formation of major metabolites, the aim of the present work was to understand the mechanisms underlying pharmacokinetic and pharmacological variability in clinic. A liquid chromatography/UV/high-resolution mass spectrometer method was developed to characterize the icotinib metabolites. The formation of 6 major metabolites was studied in recombinant CYP isozymes and human liver microsomes with specific inhibitors to identify the CYPs responsible for icotinib metabolism. The metabolic pathways observed in vitro are consistent with those observed in human. Results demonstrated that the metabolites are predominantly catalyzed by CYP3A4 (77%∼87%), with a moderate contribution from CYP3A5 (5%∼15%) and CYP1A2 (3.7%∼7.5%). The contribution of CYP2C8, 2C9, 2C19, and 2D6 is insignificant. Based on our observations, to minimize drug-drug interaction risk in clinic, coprescription of icotinib with strong CYP3A inhibitors or inducers must be weighed. CYP1A2, a highly inducible enzyme in the smoking population, may also represent a determinant of pharmacokinetic and pharmacological variability of icotinib, especially in lung cancer patients with smoking history. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  12. Mammographic interpretation

    International Nuclear Information System (INIS)

    Tabor, L.

    1987-01-01

    For mammography to be an effective diagnostic method, it must be performed to a very high standard of quality. Otherwise many lesions, in particular cancer in its early stages, will simply not be detectable on the films, regardless of the skill of the mammographer. Mammographic interpretation consists of two basic steps: perception and analysis. The process of mammographic interpretation begins with perception of the lesion on the mammogram. Perception is influenced by several factors. One of the most important is the parenchymal pattern of the breast tissue, detection of pathologic lesions being easier with fatty involution. The mammographer should use a method for the systematic viewing of the mammograms that will ensure that all parts of each mammogram are carefully searched for the presence of lesions. The method of analysis proceeds according to the type of lesion. The contour analysis of primary importance in the evaluation of circumscribed tumors. After having analyzed the contour and density of a lesion and considered its size, the mammographer should be fairly certain whether the circumscribed tumor is benign or malignant. Fine-needle puncture and/or US may assist the mammographer in making this decision. Painstaking analysis is required because many circumscribed tumors do not need to be biopsied. The perception of circumscribed tumors seldom causes problems, but their analysis needs careful attention. On the other hand, the major challenge with star-shaped lesions is perception. They may be difficult to discover when small. Although the final diagnosis of a stellate lesion can be made only with the help of histologic examination, the preoperative mammorgraphic differential diagnosis can be highly accurate. The differential diagnostic problem is between malignant tumors (scirrhous carcinoma), on the one hand, and traumatic fat necrosis as well as radial scars on the other hand

  13. Mammographic screening programmes in Europe

    DEFF Research Database (Denmark)

    Giordano, Livia; von Karsa, Lawrence; Tomatis, Mariano

    2012-01-01

    To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe.......To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe....

  14. The impact of Cytochrome P450 CYP1A2, CYP2C9, CYP2C19 and CYP2D6 genes on suicide attempt and suicide risk-a European multicentre study on treatment-resistant major depressive disorder.

    Science.gov (United States)

    Höfer, Peter; Schosser, Alexandra; Calati, Raffaella; Serretti, Alessandro; Massat, Isabelle; Kocabas, Neslihan Aygun; Konstantinidis, Anastasios; Linotte, Sylvie; Mendlewicz, Julien; Souery, Daniel; Zohar, Joseph; Juven-Wetzler, Alzbeta; Montgomery, Stuart; Kasper, Siegfried

    2013-08-01

    Recently published data have reported associations between cytochrome P450 metabolizer status and suicidality. The aim of our study was to investigate the role of genetic polymorphisms of the cytochrome P450 genes on suicide risk and/or a personal history of suicide attempts. Two hundred forty-three major depressive disorder patients were collected in the context of a European multicentre resistant depression study and treated with antidepressants at adequate doses for at least 4 weeks. Suicidality was assessed using the Mini International Neuropsychiatric Interview and the Hamilton Rating Scale for Depression (HAM-D). Treatment response was defined as HAM-D ≤ 17 and remission as HAM-D ≤ 7 after 4 weeks of treatment with antidepressants at adequate dose. Genotyping was performed for all relevant variations of the CYP1A2 gene (*1A, *1F, *1C, *1 J, *1 K), the CYP2C9 gene (*2, *3), the CYP2C19 gene (*2, *17) and the CYP2D6 gene (*3, *4, *5, *6, *9, *19, *XN). No association between both suicide risk and personal history of suicide attempts, and the above mentioned metabolic profiles were found after multiple testing corrections. In conclusion, the investigated cytochrome gene polymorphisms do not seem to be associated with suicide risk and/or a personal history of suicide attempts, though methodological and sample size limitations do not allow definitive conclusions.

  15. Anxiety in mammography: mammographers' and clients' perspectives

    International Nuclear Information System (INIS)

    Galletta, S.; Joel, N.; Maguire, R.; Weaver, K.; Poulos, A.

    2003-01-01

    The aim of this study was to identify causes of anxiety experienced by mammographers and clients during mammography and strategies to decrease the anxiety generated by the mammographic procedure. Two questionnaires were distributed: one to mammographers in public and private centres within NSW, the other to women (clients) who have experienced mammography. Mammographers' and clients' rankings of causes of clients' anxiety demonstrated many similarities indicating the mammographers' acknowledgement of factors contributing to client anxiety. Thematic analysis provided important qualitative data concerning anxiety experienced by both mammographers and clients and the influence of mammographer and client behaviour on that anxiety. The results of this study have provided important new knowledge for mammographic practice and mammography education. By understanding the causes of anxiety experienced by clients, mammographers can provide an informed, empathetic approach to the mammographic process. By acknowledging factors which increase their own anxiety mammographers can reduce the impact of this on themselves and on their clients. Copyright (2003) Australian Institute of Radiography

  16. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  17. Influence of lifestyle factors on mammographic density in postmenopausal women.

    Directory of Open Access Journals (Sweden)

    Judith S Brand

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer. Apart from hormone replacement therapy (HRT, little is known about lifestyle factors that influence breast density. METHODS: We examined the effect of smoking, alcohol and physical activity on mammographic density in a population-based sample of postmenopausal women without breast cancer. Lifestyle factors were assessed by a questionnaire and percentage and area measures of mammographic density were measured using computer-assisted software. General linear models were used to assess the association between lifestyle factors and mammographic density and effect modification by body mass index (BMI and HRT was studied. RESULTS: Overall, alcohol intake was positively associated with percent mammographic density (P trend  = 0.07. This association was modified by HRT use (P interaction  = 0.06: increasing alcohol intake was associated with increasing percent density in current HRT users (P trend  = 0.01 but not in non-current users (P trend  = 0.82. A similar interaction between alcohol and HRT was found for the absolute dense area, with a positive association being present in current HRT users only (P interaction  = 0.04. No differences in mammographic density were observed across categories of smoking and physical activity, neither overall nor in stratified analyses by BMI and HRT use. CONCLUSIONS: Increasing alcohol intake is associated with an increase in mammography density, whereas smoking and physical activity do not seem to influence density. The observed interaction between alcohol and HRT may pose an opportunity for HRT users to lower their mammographic density and breast cancer risk.

  18. Ethnicity, Soybean Consumption, and Mammographic Densities

    National Research Council Canada - National Science Library

    Maskarinec, Gertraud

    1997-01-01

    The purpose of this study is to determine whether mammographic density patterns differ by ethnic background and to explore the possible association of a soy rich diet with mammographic density patterns...

  19. Force balancing in mammographic compression

    International Nuclear Information System (INIS)

    Branderhorst, W.; Groot, J. E. de; Lier, M. G. J. T. B. van; Grimbergen, C. A.; Neeter, L. M. F. H.; Heeten, G. J. den; Neeleman, C.

    2016-01-01

    Purpose: In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body during compression. This leads to unnecessary stretching of the skin and other tissues around the breast, which can make the imaging procedure more painful for the patient. The goal of this study was to implement a method to measure and minimize the force imbalance, and to assess its feasibility as an objective and reproducible method of setting the image receptor height. Methods: A trial was conducted consisting of 13 craniocaudal mammographic compressions on a silicone breast phantom, each with the image receptor positioned at a different height. The image receptor height was varied over a range of 12 cm. In each compression, the force exerted by the compression paddle was increased up to 140 N in steps of 10 N. In addition to the paddle force, the authors measured the force exerted by the image receptor and the reaction force exerted on the patient body by the ground. The trial was repeated 8 times, with the phantom remounted at a slightly different orientation and position between the trials. Results: For a given paddle force, the obtained results showed that there is always exactly one image receptor height that leads to a balance of the forces on the breast. For the breast phantom, deviating from this specific height increased the force imbalance by 9.4 ± 1.9 N/cm (6.7%) for 140 N paddle force, and by 7.1 ± 1.6 N/cm (17.8%) for 40 N paddle force. The results also show that in situations where the force exerted by the image receptor is not measured, the craniocaudal force imbalance can still be determined by positioning the patient on a weighing scale and observing the changes in displayed weight during the procedure. Conclusions: In mammographic breast

  20. Malignant Lesions as Mammographically Appearing Intramammary Ganglia

    International Nuclear Information System (INIS)

    Martinez-Miraveta, P.; Pons, M. J.; Pina, L. J.; Zornoza, G.

    2004-01-01

    Intramammary ganglia are frequent mammographic findings of no pathological importance. We present two cases of malignant breast lesions whose mammographic appearance could resemble that of intramammary ganglia. Although the mammographic appearance of a lesion is similar to that of intramammary ganglia, it should be carefully studied, especially if it presents a poorly defined border or is palpable. (Author)

  1. Mammographic features of breast carcinoma: mammographic-pathologic correlation

    International Nuclear Information System (INIS)

    Gu Yajia; Wang Jiuhua; Chen Tongzhen; Zhang Tingqiu; Zhou Kangrong

    2003-01-01

    Objective: To analyze the mammographic features of breast carcinoma and the correlation between the mammographic and pathologic findings. Methods: A prospective study of 397 consecutive mammograms in patients with breast carcinoma, including infiltrating ductal carcinoma (IDC, n=297), ductal carcinoma in situ (DCIS) and DCIS associated with small invasive foci (n=38), mucinous carcinoma (n=21), medullary carcinoma (n=22) and invasive lobular carcinoma (n=19), was performed to determine the correlations between the mammographic and pathologic findings. Results: (1) Microcalcifications appeared in 170 cases (42.8%), a mass in 258 cases (65.0%), and distortion in 33 cases (8.3%), respectively. (2) Microcalcifications were more commonly associated with DCIS and IDC (χ 2 =30.90, P 2 =30.87, P 2 =27.40, P 2 =6.22, P 2 =7.19, P < 0.01). Conclusion: The common features of breast carcinoma in mammography were microcalcifications, microcalcifications with a mass, a mass, and distortion IDC was the commonest in breast carcinoma, and could be considered when mammographic malignant features above mentioned were found except the appearance of microcalcifications alone, which was firstly suggestive of DCIS. A mass also appeared in medullary and mucinous carcinoma, and distortion appeared in invasive lobular carcinoma

  2. Task-Specific Optimization of Mammographic Systems

    National Research Council Canada - National Science Library

    Saunders, Robert

    2005-01-01

    .... This model was verified by a human observer performance experiment. The next objective explored the physical properties of a digital mammographic system, including resolution, noise, efficiency, and lag...

  3. Serum osteoprotegerin levels and mammographic density among high-risk women.

    Science.gov (United States)

    Moran, Olivia; Zaman, Tasnim; Eisen, Andrea; Demsky, Rochelle; Blackmore, Kristina; Knight, Julia A; Elser, Christine; Ginsburg, Ophira; Zbuk, Kevin; Yaffe, Martin; Narod, Steven A; Salmena, Leonardo; Kotsopoulos, Joanne

    2018-06-01

    Mammographic density is a risk factor for breast cancer but the mechanism behind this association is unclear. The receptor activator of nuclear factor κB (RANK)/RANK ligand (RANKL) pathway has been implicated in the development of breast cancer. Given the role of RANK signaling in mammary epithelial cell proliferation, we hypothesized this pathway may also be associated with mammographic density. Osteoprotegerin (OPG), a decoy receptor for RANKL, is known to inhibit RANK signaling. Thus, it is of interest to evaluate whether OPG levels modify breast cancer risk through mammographic density. We quantified serum OPG levels in 57 premenopausal and 43 postmenopausal women using an enzyme-linked immunosorbent assay (ELISA). Cumulus was used to measure percent density, dense area, and non-dense area for each mammographic image. Subjects were classified into high versus low OPG levels based on the median serum OPG level in the entire cohort (115.1 pg/mL). Multivariate models were used to assess the relationship between serum OPG levels and the measures of mammographic density. Serum OPG levels were not associated with mammographic density among premenopausal women (P ≥ 0.42). Among postmenopausal women, those with low serum OPG levels had higher mean percent mammographic density (20.9% vs. 13.7%; P = 0.04) and mean dense area (23.4 cm 2 vs. 15.2 cm 2 ; P = 0.02) compared to those with high serum OPG levels after covariate adjustment. These findings suggest that low OPG levels may be associated with high mammographic density, particularly in postmenopausal women. Targeting RANK signaling may represent a plausible, non-surgical prevention option for high-risk women with high mammographic density, especially those with low circulating OPG levels.

  4. Scattering influence in mammographic image

    International Nuclear Information System (INIS)

    Poletti, Martin Eduardo; Almeida, Adelaide de

    1996-01-01

    The quantification of mammographic images affected by scattered radiation is studied. The average glandular dose as a function of kVp and breast thickness for breast composition 50/50% is also evaluated. The results show that the contrast decreases with increasing of kVp and breast thickness, and the average glandular dose increase with increasing breast thickness and decreases with increasing kVp

  5. Ultrasound detection of nonpalpable mammographically occult malignancy

    International Nuclear Information System (INIS)

    Simpson, W.L.; Hermann, G.; Rausch, D.R.; Sherman, J.; Feig, S.A.; Bleiweiss, I.J.; Jaffer, S.

    2008-01-01

    To evaluate the prevalence of occult malignancy with screening breast ultrasound. All ultrasound-guided core needle breast biopsies performed between January 1, 1999, and June 30, 2001, were retrospectively reviewed. Lesions were identified during screening breast ultrasound in high-risk women with no mammographic or palpable abnormality in either breast, a unilateral mammographic or palpable abnormality in the contralateral breast, or a unilateral mammographic or palpable abnormality in a different quadrant of the same breast. All ultrasound-detected lesions were histologically verified. Six hundred and fifty-two women with a mean age of 49 years underwent 698 biopsies during the study period. Three hundred and forty-nine of these lesions were detected at screening breast ultrasound. Out of 349, 11 (3.2%) had a mammographically and clinically occult malignancy. Nine cancers were found in women with no mammographic or palpable abnormality. Two cancers were found in the same breast as the mammographic or palpable abnormality. None were found in the breast contralateral to a palpable or mammographic abnormality. Screening breast ultrasound of high-risk women has a similar detection rate for occult carcinoma as screening mammography, but has a low positive predictive value in cases where biopsy is performed. (author)

  6. Mammographic compression in Asian women.

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (pAsian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  7. Diagnostic implications of asymmetrical mammographic patterns

    International Nuclear Information System (INIS)

    Asenjo, M.; Ania, B.J.

    1997-01-01

    To analyze the effect of asymmetrical mammographic patterns of the diagnosis of breast cancer. In a series of 6, 476 patients referred to a Breast Imaging Diagnosis Unit, we excluded males, women with previous breast surgery, and cases in which mammography was not performed, which left 5,203 women included. Each breast was classified according to one of four patterns of mammographic parenchymal density. Asymmetry was considered to exist when a patient's breasts had different patterns. Breast cancer was confirmed histologically in 282 (5.4%) women. The mammographic pattern was asymmetrical in 8% of the women with cancer and in 2% of the women without cancer (p<0.001). Fine-needle aspiration biopsy was performed in 78% and 96% (p=0.04), respectively, of the women with and without mammographic asymmetry who had neoplasms, and in 33% and 22% (p=0.02), respectively, of the women with and without mammographic asymmetry who did not have neoplasms. Asymmetrical mammographic pattern was four times more frequent in the women with breast cancer. This asymmetry decreased the frequency of needle biopsy in women with cancer, but increased the frequency of needle biopsy in women without cancer. (Author) 11 refs

  8. Nonpalpable breast cancer : mammographic and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-08-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group.

  9. Nonpalpable breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan

    1998-01-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group

  10. CYP1A2 polymorphisms in slow melatonin metabolisers: a possible relationship with autism spectrum disorder?

    NARCIS (Netherlands)

    Braam, W.J.; Keijzer, H.; Struijker Boudier, H.S.; Didden, H.C.M.; Smits, M.G.; Curfs, L.M.G.

    2013-01-01

    Background In some of our patients with intellectual disabilities (ID) and sleep problems, the initial good response to melatonin disappeared within a few weeks after starting treatment. In these patients melatonin levels at noon were extremely high (>50pg/ml). We hypothesise that the disappearing

  11. Mammographic appearances of male breast disease.

    Science.gov (United States)

    Appelbaum, A H; Evans, G F; Levy, K R; Amirkhan, R H; Schumpert, T D

    1999-01-01

    Various male breast diseases have characteristic mammographic appearances that can be correlated with their pathologic diagnoses. Male breast cancer is usually subareolar and eccentric to the nipple. Margins of the lesions are more frequently well defined, and calcifications are rarer and coarser than those occurring in female breast cancer. Gynecomastia usually appears as a fan-shaped density emanating from the nipple, gradually blending into surrounding fat. It may have prominent extensions into surrounding fat and, in some cases, an appearance similar to that of a heterogeneously dense female breast. Although there are characteristic mammographic features that allow breast cancer in men to be recognized, there is substantial overlap between these features and the mammographic appearance of benign nodular lesions. The mammographic appearance of gynecomastia is not similar to that of male breast cancer, but in rare cases, it can mask malignancy. Gynecomastia can be mimicked by chronic inflammation. All mammographically lucent lesions of the male breast appear to be benign, similar to such lesions in the female breast.

  12. Epidemiologic Studies of Isoflavones & Mammographic Density

    Science.gov (United States)

    Maskarinec, Gertraud; Verheus, Martijn; Tice, Jeffrey A.

    2010-01-01

    Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density. PMID:22253990

  13. Epidemiologic Studies of Isoflavones & Mammographic Density

    Directory of Open Access Journals (Sweden)

    Jeffrey A. Tice

    2010-01-01

    Full Text Available Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density.

  14. Advanced techniques in digital mammographic images recognition

    International Nuclear Information System (INIS)

    Aliu, R. Azir

    2011-01-01

    Computer Aided Detection and Diagnosis is used in digital radiography as a second thought in the process of determining diagnoses, which reduces the percentage of wrong diagnoses of the established interpretation of mammographic images. The issues that are discussed in the dissertation are the analyses and improvement of advanced technologies in the field of artificial intelligence, more specifically in the field of machine learning for solving diagnostic problems and automatic detection of speculated lesions in digital mammograms. The developed of SVM-based ICAD system with cascade architecture for analyses and comparison mammographic images in both projections (CC and MLO) gives excellent result for detection and masses and microcalcifications. In order to develop a system with optimal performances of sensitivity, specificity and time complexity, a set of relevant characteristics need to be created which will show all the pathological regions that might be present in the mammographic image. The structure of the mammographic image, size and the large number of pathological structures in this area are the reason why the creation of a set of these features is necessary for the presentation of good indicators. These pathological structures are a real challenge today and the world of science is working in that direction. The doctoral dissertation showed that the system has optimal results, which are confirmed by experts, and institutions, which are dealing with these same issues. Also, the thesis presents a new approach for automatic identification of regions of interest in the mammographic image where regions of interest are automatically selected for further processing mammography in cases when the number of examined patients is higher. Out of 480 mammographic images downloaded from MIAS database and tested with ICAD system the author shows that, after separation and selection of relevant features of ICAD system the accuracy is 89.7% (96.4% for microcalcifications

  15. Indications and guidelines for mammographic examinations

    International Nuclear Information System (INIS)

    Kalisher, L.; Schaffer, D.

    1977-01-01

    The value of mammography in evaluating the asymptomatic patient has been clearly demonstrated by the HIP program, as well as the National Cancer Institute's breast demonstration projects. A one-third reduction in mortality from breast cancer in mammographically screened women has been substantiated. Nonetheless, questions concerning the long-term effects of repeated radiation exposure associated with mammography have been raised, and for this reason judicious selection of women is urged. In general, women who are asymptomatic or at high risk for breast carcinoma should be evaluated with a planned regimen. Mammographic guidelines and recommendations for attaining the greatest benefit at the lowest possible risk are suggested

  16. Mammographic varicosities indicative of a superior mediastinal ...

    African Journals Online (AJOL)

    In addition, an abnormal calibre of the superficial veins can reflect not only underrying breast pathology, but a collateral venous return resulting from an upper mediastinal obstruction. A case mammographically demonstrating mammary varicosities resulting from a superior mediastinal syndrome is described. S. Afr. Med.

  17. State supervision of SONS in the mammographic departments

    International Nuclear Information System (INIS)

    Jursikova, E.; Kodl, O.

    2008-01-01

    State Office for Nuclear Safety has been performed the state supervision over radiation protection at all mammographic centres in the Czech Republic. Inspections are carried out on the basis of requirements of: Act No. 18/1997 Coll., Atomic Act, subsequently amended; Act No. 552/1991 Coll., Supervision Act, subsequently amended; Decree No. 307 /2002 Coll., On radiation protection, as amended by Decree No. 499/2005 Coll. 137 mammography X-ray units have been used actively by 108 independent licensees since 1 September 2008. The mammography screening program started in September 2002. The screening program was carried out at 59 working places last year and already at 66 workplaces with accreditation from 1 up to 3 years this year. The activity of the centres is monitored and inspected continuously (not only by SONS). Inspections at 35 workplaces were carried out last year .The doses are significantly below guidance levels at major part of working places. Most of detected defects were eliminated after inspections. The quality of mammographic workplaces in the Czech Republic has been gradually increased and improved. (authors)

  18. Posterior breast cancer: Mammographic and ultrasonographic features

    Directory of Open Access Journals (Sweden)

    Janković Ana

    2013-01-01

    Full Text Available Background/Aim. Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers. Methods. The study included 40 women with palpable, histopathological confirmed posterior breast cancer. Mammographic and ultrasonographic features were defined according to Breast Imaging Reporting and Data System (BI-RADS lexicon. Results. Based on standard two-view mammography 87.5%, of the cases were classified as BI-RADS 4 and 5 categories, while after additional mammographic views all the cases were defined as BIRADS 4 and 5 categories. Among 96 mammographic descriptors, the most frequent were: spiculated mass (24.0%, architectural distortion (16.7%, clustered microcalcifications (12.6% and focal asymmetric density (12.6%. The differentiation of the spiculated mass was significantly associated with the possibility to visualize the lesion at two-view mammography (p = 0.009, without the association with lesion diameter (p = 0.083 or histopathological type (p = 0.055. Mammographic signs of invasive lobular carcinoma were significantly different from other histopathological types (architectural distortion, p = 0.003; focal asymmetric density, p = 0.019; association of four or five subtle signs of malignancy, p = 0.006. All cancers were detectable by ultrasonography. Mass lesions were found in 82.0% of the cases. Among 153 ultrasonographic descriptors, the most frequent were: irregular mass (15.7%, lobulated mass (7.2%, abnormal color Doppler signals (20.3%, posterior acoustic attenuation (18.3%. Ultrasonographic BI-RADS 4 and 5 categories were defined in 72.5% of the cases, without a significant difference among various histopathological types (p = 0

  19. A uniform system for mammographic reporting BI-RADS

    International Nuclear Information System (INIS)

    Masroor, I.; Ahmad, M. N.; Sheikh, M. Y.

    2001-01-01

    Breast image reporting and data system (BI-RADS) is a new system of categorizing and reporting mammographs and mammographic findings recommended by American College of Radiology. The importance of BI-RADS and final assessment categories are discussed. The purpose is to introduce the above-mentioned mammographic reporting system so that it becomes a standard terminology among the medical personnel, involved in the diagnosis and management of breast diseases. (author)

  20. Analysis of mammographic findings of breast cancer

    International Nuclear Information System (INIS)

    Park, Hyun Joo; Han, Heon; Yang, Dal Mo; Chung, Hyo Sun; Kim, Jee Eun; Kim, Young Chae

    1995-01-01

    This study is to describe authors' experience on mammographic findings of breast cancer and to know if there is difference between 35 years of age or younger and older groups. Mammograms of 72 patients with breast cancer detected from January, 1991 to December, 1993 were retrospectively analysed. Mammographic findings were classified into mass only, mass with microcalcifications, microcalcifications only and others. Marginal characteristics of mass were classified into spiculated, poorly marginated and well marginated. Shape of microcalcifications were classified into casting, granular and mixed types. These findings were compared between 35 years of age or younger and older groups. Mammogram showed mass only in 33 patients (46%), mass with microcalcifications in 26 patients (36%), microcalcifications only in seven (10%) and other findings in six (8%). Other findings were architectural distortion, asymmetric high density and incidental breast carcinoma from paraffinoma in one patient respectively, and dense breast in three patients. The margins of the breast mass were spiculated in ten (17%). poorly marginated in 30 (51%), well-marginated in 19 (32%). Shape of microcalcifications were casting type in 13 (40%). granular in 14 (42%) and mixed in six (18%) cases. 3 patients had dense breast with which mammography did not demonstrate the lesion. 3 patients without mammographically demonstrable lesions due to dense breasts were under 35 years in age, and there was statistically significant difference between the two groups (ρ -value < 0.05). Microcalcifications only was more common findings in 35 years of age or younger. The most important mammographic findings of breast cancer were mass and microcalcifications. Architectural distortion and asymmetric high density were additional findings. In 35 years of age or younger, microcalcifications only was an important finding because mass lesions are frequently masked by dense breast. Thus other imaging modalities, such as

  1. Ultrasonographic Findings of Mammographic Architectural Distortion

    International Nuclear Information System (INIS)

    Ma, Jeong Hyun; Kang, Bong Joo; Cha, Eun Suk; Hwangbo, Seol; Kim, Hyeon Sook; Park, Chang Suk; Kim, Sung Hun; Choi, Jae Jeong; Chung, Yong An

    2008-01-01

    To review the sonographic findings of various diseases showing architectural distortion depicted under mammography. We collected and reviewed architectural distortions observed under mammography at our health institution between 1 March 2004, and 28 February 2007. We collected 23 cases of sonographically-detected mammographic architectural distortions that confirmed lesions after surgical resection. The sonographic findings of mammographic architectural distortion were analyzed by use of the BI-RADS lexicon for shape, margin, lesion boundary, echo pattern, posterior acoustic feature and orientation. There were variable diseases that showed architectural distortion depicted under mammography. Fibrocystic disease was the most common presentation (n = 6), followed by adenosis (n = 2), stromal fibrosis (n = 2), radial scar (n = 3), usual ductal hyperplasia (n = 1), atypical ductal hyperplasia (n = 1) and mild fibrosis with microcalcification (n = 1). Malignant lesions such as ductal carcinoma in situ (DCIS) (n = 2), lobular carcinoma in situ (LCIS) (n = 2), invasive ductal carcinoma (n = 2) and invasive lobular carcinoma (n = 1) were observed. As observed by sonography, shape was divided as irregular (n = 22) and round (n = 1). Margin was divided as circumscribed (n = 1), indistinct (n = 7), angular (n = 1), microlobulated (n = 1) and sipculated (n = 13). Lesion boundary was divided as abrupt interface (n = 11) and echogenic halo (n = 12). Echo pattern was divided as hypoechoic (n = 20), anechoic (n = 1), hyperechoic (n = 1) and isoechoic (n = 1). Posterior acoustic feature was divided as posterior acoustic feature (n = 7), posterior acoustic shadow (n = 15) and complex posterior acoustic feature (n = 1). Orientation was divided as parallel (n = 12) and not parallel (n = 11). There were no differential sonographic findings between benign and malignant lesions. This study presented various sonographic findings of mammographic architectural distortion and that it is

  2. THE MAMMOGRAPHIC CALCIFICATIONS IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    Tang Ruiying; Liu Jingxian; Gaowen

    1998-01-01

    Objective: This study was performed to exam the relativeship between mammographic calcifications and breast cancer. Methods: All of the 184 patients with breast diseases underwent mammography before either an open biopsy or a mastectomy. The presence,morphology, and distribution of calcifications visualized on mammograms for breast cancer were compared with the controls who remained cancer free. Statistical comparisons were made by using the x2 test. Results:Of the 184 patients with breast diaeases, 93 malignant and 91 benign lesions were histologically confirmed.Calcifications were visualized on mammograms in 60(64%) of 93 breast cancers and 26 (28%) of 91 non breast cancers. The estimated odds ratio (OR) of breast cancer was 4.5 in women with calcifications seen on mammograms, compared with those having none (P<0.01). Of the 60 breast carcinomas having mammographic calcifications, 28 (47%) were infiltrating ductal carcinomas.There were only 8 (24%) cases with infiltrating ductal cancers in the group of without calcifications seen on the mammograms (P<0.05). Conclusion: Our finding suggests that mammographic calcification appears to be a risk factor for breast cancer. The granular and linear cast type calcification provide clues to the presence of breast cancer, especially when the carcinomas without associated masses were seen on mammograms.

  3. Bilateral breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Oh, Ki Keun; Jun, Hwang Yoon; Lee, Byung Chan; Lee, Kyong Sik; Lee, Yong Hee

    1997-01-01

    To evaluate the mammographic and clinical features of bilateral breast cancer. We retrospectively reviewed clinical records(n=23) and mammograms (n=15) of 23 patients with bilateral breast cancer. Patients' age, location of the tumor and pathologic staging were determined from clinical records. Mammographic features were classified as spiculated mass, nonspiculated mass, mass with microcalcification, microcalcification only, asymmetric density, and normal. Of the 23 cases of bilateral breast cancer, 8(34.8%) were synchronous and 15(65.2%) were metachronous. Age at diagnosis of cancer in the first breast was between 27 and 59(mean 43) years ; there was no statistically significant difference in mean age between patients with synchronous and metachronous cancer. The mean interval between the diagnosis of each lesion of the metachronous pairs was 9.1 years. In 11 of 23 cases(48%), tumors were locaated in the same quadrant, and in the other 12 cases(52%), they were in different quadrant. At mammography, five of 15 metachronous cancers(33%) were similar in appearance and 10 pairs(67%) were different. In 4 of 23 cases(17%), cancer in the first breast was at stage 0 and stage 1, and in 13 of 23(57%), cancer in the second breast was at this same stage. In bilateral breast cancer, the two breasts frequently show different mammographic features. Cancer of the second breast was at an early stage; this suggest that regular examination and mammography are important and can allow early detection of contralateral breast cancer

  4. Mammographic breast density patterns among a group of women in ...

    African Journals Online (AJOL)

    Introduction: Mammographic breast density is a measure of parenchymal breast patterns on film and in part a marker of cumulative exposure to oestrogen. The risk of breast cancer for women with increased density is up to six fold more than in women with less dense tissues. The pattern of mammographic breast density ...

  5. Changes in mammographic density and breast cancer risk

    NARCIS (Netherlands)

    Lokate, A.J.M.

    2012-01-01

    Breast cancer is the most frequently occurring cancer among women worldwide. One of the most important risk factors for breast cancer is high mammographic density. Mammographic density represents the amount of fibroglandular tissue relative to the fat tissue in the breast. Women with >75% of their

  6. Mammographic image enhancement using wavelet transform and homomorphic filter

    Directory of Open Access Journals (Sweden)

    F Majidi

    2015-12-01

    Full Text Available Mammography is the most effective method for the early diagnosis of breast cancer diseases. As mammographic images contain low signal to noise ratio and low contrast, it becomes too difficult for radiologists to analyze mammogram. To deal with the above stated problems, it is very important to enhance the mammographic images using image processing methods. This paper introduces a new image enhancement approach for mammographic images which uses the modified mathematical morphology, wavelet transform and homomorphic filter to suppress the noise of images. For performance evaluation of the proposed method, contrast improvement index (CII and edge preservation index (EPI are adopted. Experimental results on mammographic images from Pejvak Digital Imaging Center (PDIC show that the proposed algorithm improves the two indexes, thereby achieving the goal of enhancing mammographic images.

  7. Automated effect-specific mammographic pattern measures

    DEFF Research Database (Denmark)

    Raundahl, Jakob; Loog, Marco; Pettersen, Paola

    2008-01-01

    We investigate the possibility to develop methodologies for assessing effect specific structural changes of the breast tissue using a general statistical machine learning framework. We present an approach of obtaining objective mammographic pattern measures quantifying a specific biological effect......, such as hormone replacement therapy (HRT). We compare results using this approach to using standard density measures. We show that the proposed method can quantify both age related effects and effects caused by HRT. Age effects are significantly detected by our method where standard methodologies fail...

  8. Neural network recognition of mammographic lesions

    International Nuclear Information System (INIS)

    Oldham, W.J.B.; Downes, P.T.; Hunter, V.

    1987-01-01

    A method for recognition of mammographic lesions through the use of neural networks is presented. Neural networks have exhibited the ability to learn the shape andinternal structure of patterns. Digitized mammograms containing circumscribed and stelate lesions were used to train a feedfoward synchronous neural network that self-organizes to stable attractor states. Encoding of data for submission to the network was accomplished by performing a fractal analysis of the digitized image. This results in scale invariant representation of the lesions. Results are discussed

  9. Cigarette smoking and mammographic density in the Danish Diet, Cancer and Health cohort

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp; Lynge, Elsebeth; Vejborg, Ilse

    2016-01-01

    with MD. METHODS: For the 5,356 women (4,489 postmenopausal) from the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening in Copenhagen (1993-2001), we used MD (mixed/dense or fatty) assessed at the first screening after cohort entry. Active smoking (status, duration......PURPOSE: Smoking before first childbirth increases breast cancer risk, but the biological mechanism remains unknown and may involve mammographic density (MD), one of the strongest biomarkers of breast cancer risk. We aimed to examine whether active smoking and passive smoking were associated......, and intensity) and passive smoking were assessed at cohort baseline (1993-1997) via questionnaire, together with other breast cancer risk factors. Logistic regression was used to estimate associations (odds ratios, 95 % confidence intervals) between smoking and MD, adjusting for confounders. RESULTS: Two...

  10. Calcified trichinosis of pectoral muscle: mammographic appearance

    International Nuclear Information System (INIS)

    Apesteguia, L.; Murillo, A.; Biurrun, J.; Garcia-Rostan, G.; Reta, A.; Dominguez, F.

    1995-01-01

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients' diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  11. Calcified trichinosis of pectoral muscle: mammographic appearance

    Energy Technology Data Exchange (ETDEWEB)

    Apesteguia, L. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Murillo, A. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Biurrun, J. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Garcia-Rostan, G. [Servicio Anatomia Patologica, Hospital Virgen del Camino, Pamplona (Spain); Reta, A. [Servicio de Analisis Clinicos, Hospital Virgen del Camino, Pamplona (Spain); Dominguez, F. [Servicio Cirugia, Hospital Virgen del Camino, Pamplona (Spain)

    1995-12-31

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients` diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  12. Ultrasonographic and mammographic findings of gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Kyung; Choi, Gyo Chang; Hong, Hyun Sook; Kim, Young Beom; Lee, Hae Kyung; Kwon, Kui Hyang [Soonchunhyang Univ. College of Medicine, Asan (Korea, Republic of)

    1996-11-01

    The purpose of this study is to evaluate the radiologic features and clinical utility of ultrasonography and mammography in cases of gynecomastia. This study involved 40 men in whom gynecomastia had been pathologically diagnosed by surgical incision. In 21 cases, a retrospective analysis of ultrasonographic and mammographic findings was performed. Causative factors of gynecomastia among the 40 pathologically-proven cases were idiopathic or pubertal in 33 cases, related to male hormone deficiency in three cases and to chronic liver disease in four. Bi-lateral involvement was seen in 14 cases, and unilateral involvement in 26;among unilateral cases, right side was involved in 10 cases, and the left side in 16. Mammographically, a subareolar discoid lesion was present in 12 cases, diffuse increased breast density was seen in five cases and dendritic marginated subareolar lesion without microcalcification in one. Ultrasonographically, a round smooth marginated low echogenic lesion in the subareolar region was seen in five cases, a diffuse hyperechogenic pattern without definite mass in two cases and an ill defined low echogenic lesion in one. The male breast is small, so in cases of gynecomastia, ultrasonography is an effective diagnostic modality. Mamography will, however, be helpful in the detection of microcalcification in cases of gynecomastia seen on sonography.

  13. Tumor location and detectability in mammographic screening

    International Nuclear Information System (INIS)

    Schmitt, E.L.; Threatt, B.

    1982-01-01

    The adequacy of a film mammogram that does not visualize the retromammary space or ribs has concerned radiologists. The 79 prevalent cancers detected in the 10,000 self-referred woman at the University of Michigan Breast Cancer Detection Demonstration Project were analyzed for number of films required to detect the cancer, relationship of the cancer to the posterior edge of the film, number of occult lesions, tumor size, histologic type, sensitivity of detection method, and number of interval carcinomas. The mammograms were obtained using a dedicated mammographic machine and the upright position, with visualization of the anterior axillary fold on the mediolateral view. The ribs were not imaged. Of the 79 cancers, 76 were detectable on the mammogram. All were visualized on the mediolateral view, while three were not imaged on the craniocaudal view. Twelve percent of the cancers were within 1 cm of the posterior edge of the film. Only six ''interval'' carcinomas were found in the 10,000 patients within the year of the initial examinations; these women had dense P2 or DY mammographic parenchymal patterns. The detected cancers were smaller and had a significantly higher percentage of noninvasive cancers than in a symptomatic clinical population. Thus, properly exposed film mammograms using vigorous breast compression examine the breast adequately without visualizing the ribs

  14. Multiscale wavelet representations for mammographic feature analysis

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu

    1992-12-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet coefficients, enhanced by linear, exponential and constant weight functions localized in scale space. By improving the visualization of breast pathology we can improve the changes of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  15. Mammographic feature enhancement by multiscale analysis

    International Nuclear Information System (INIS)

    Laine, A.F.; Schuler, S.; Fan, J.; Huda, W.

    1994-01-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis by overcomplete multiresolution representations. The authors show that efficient representations may be identified within a continuum of scale-space and used to enhance features of importance to mammography. Methods of contrast enhancement are described based on three overcomplete multiscale representations: (1) the dyadic wavelet transform (separable), (2) the var-phi-transform (nonseparable, nonorthogonal), and (3) the hexagonal wavelet transform (nonseparable). Multiscale edges identified within distinct levels of transform space provide local support for image enhancement. Mammograms are reconstructed from wavelet coefficients modified at one or more levels by local and global nonlinear operators. In each case, edges and gain parameters are identified adaptively by a measure of energy within each level of scale-space. The authors show quantitatively that transform coefficients, modified by adaptive nonlinear operators, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. The results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. The authors demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology, they can improve chances of early detection while requiring less time to evaluate mammograms for most patients

  16. Contour tracing for segmentation of mammographic masses

    International Nuclear Information System (INIS)

    Elter, Matthias; Held, Christian; Wittenberg, Thomas

    2010-01-01

    CADx systems have the potential to support radiologists in the difficult task of discriminating benign and malignant mammographic lesions. The segmentation of mammographic masses from the background tissue is an important module of CADx systems designed for the characterization of mass lesions. In this work, a novel approach to this task is presented. The segmentation is performed by automatically tracing the mass' contour in-between manually provided landmark points defined on the mass' margin. The performance of the proposed approach is compared to the performance of implementations of three state-of-the-art approaches based on region growing and dynamic programming. For an unbiased comparison of the different segmentation approaches, optimal parameters are selected for each approach by means of tenfold cross-validation and a genetic algorithm. Furthermore, segmentation performance is evaluated on a dataset of ROI and ground-truth pairs. The proposed method outperforms the three state-of-the-art methods. The benchmark dataset will be made available with publication of this paper and will be the first publicly available benchmark dataset for mass segmentation.

  17. A prototype for a mammographic head and related developments

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L

    2004-02-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni.

  18. A prototype for a mammographic head and related developments

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L.

    2004-01-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni

  19. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    International Nuclear Information System (INIS)

    Annovazzi, A.; Amendolia, S.R.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M.E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-01-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18x24 cm 2 ), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%

  20. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Science.gov (United States)

    Annovazzi, A.; Amendolia, S. R.; Bigongiari, A.; Bisogni, M. G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M. E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-06-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18×24 cm 2), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma "La Sapienza", Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  1. Monte Carlo simulation of a mammographic test phantom

    International Nuclear Information System (INIS)

    Hunt, R. A.; Dance, D. R.; Pachoud, M.; Carlsson, G. A.; Sandborg, M.; Ullman, G.

    2005-01-01

    A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units. (authors)

  2. Enhancement and denoising of mammographic images for breast disease detection

    International Nuclear Information System (INIS)

    Yazdani, S.; Yusof, R.; Karimian, A.; Hematian, A.; Yousefi, M.

    2012-01-01

    In these two decades breast cancer is one of the leading cause of death among women. In breast cancer research, Mammographic Image is being assessed as a potential tool for detecting breast disease and investigating response to chemotherapy. In first stage of breast disease discovery, the density measurement of the breast in mammographic images provides very useful information. Because of the importance of the role of mammographic images the need for accurate and robust automated image enhancement techniques is becoming clear. Mammographic images have some disadvantages such as, the high dependence of contrast upon the way the image is acquired, weak distinction in splitting cyst from tumor, intensity non uniformity, the existence of noise, etc. These limitations make problem to detect the typical signs such as masses and microcalcifications. For this reason, denoising and enhancing the quality of mammographic images is very important. The method which is used in this paper is in spatial domain which its input includes high, intermediate and even very low contrast mammographic images based on specialist physician's view, while its output is processed images that show the input images with higher quality, more contrast and more details. In this research, 38 mammographic images have been used. The result of purposed method shows details of abnormal zones and the areas with defects so that specialist could explore these zones more accurately and it could be deemed as an index for cancer diagnosis. In this study, mammographic images are initially converted into digital images and then to increase spatial resolution power, their noise is reduced and consequently their contrast is improved. The results demonstrate effectiveness and efficiency of the proposed methods. (authors)

  3. Mammographic Breast Density in a Cohort of Medically Underserved Women

    Science.gov (United States)

    2015-12-01

    was a training year and during Years 2 through 4 a case-control study of obesity , insulin resistance and mammographic breast density was conducted. A...factors including health literacy, and to collect anthropometric measurements and fasting blood, 3) to assay blood for select hormones and growth...factors, 4) to perform statistical analyses to determine the associations between obesity and insulin resistance and mammographic breast density, and 5

  4. The mammographic spectrum of intraductal carcinoma

    International Nuclear Information System (INIS)

    Ikeda, D.M.; Andersson, I.

    1988-01-01

    To analyze the atypical radiographic spectrum of ductal carcinoma in situ (DCIS), the authors retrospectively reviewed the mammograms of 190 women who had biopsy-proved DCIS at Malmo General Hospital between January 1976 and March 1988. Of these, 117 (61.6%) showed clustered microcalcifications as the major abnormality, a finding often associated with DCIS. The remaining 73 women (38.4%) had either negative mammograms (30 women) or radiographic findings not usually associated with DCIS (43 women), including circumscribed masses (15 women) and focal conglomerates of prominent ducts and nodules (12 cases). Since treatment of DCIS may cure the disease, the radiologist should learn to recognize the more unusual mammographic manifestations of intraductal carcinoma

  5. The Mammographic Head Demonstrator Developed in the Framework of the “IMI” Project:. First Imaging Tests Results

    Science.gov (United States)

    Bisogni, Maria Giuseppina

    2006-04-01

    In this paper we report on the performances and the first imaging test results of a digital mammographic demonstrator based on GaAs pixel detectors. The heart of this prototype is the X-ray detection unit, which is a GaAs pixel sensor read-out by the PCC/MEDIPIXI circuit. Since the active area of the sensor is 1 cm2, 18 detectors have been organized in two staggered rows of nine chips each. To cover the typical mammographic format (18 × 24 cm2) a linear scanning is performed by means of a stepper motor. The system is integrated in mammographic equipment comprehending the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies in collaboration with the universities of Ferrara, Roma “La Sapienza”, Pisa and the INFN.

  6. Image quality analysis of digital mammographic equipments

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, P.; Pascual, A.; Verdu, G. [Valencia Univ. Politecnica, Chemical and Nuclear Engineering Dept. (Spain); Rodenas, F. [Valencia Univ. Politecnica, Applied Mathematical Dept. (Spain); Campayo, J.M. [Valencia Univ. Hospital Clinico, Servicio de Radiofisica y Proteccion Radiologica (Spain); Villaescusa, J.I. [Hospital Clinico La Fe, Servicio de Proteccion Radiologica, Valencia (Spain)

    2006-07-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  7. Image quality analysis of digital mammographic equipments

    International Nuclear Information System (INIS)

    Mayo, P.; Pascual, A.; Verdu, G.; Rodenas, F.; Campayo, J.M.; Villaescusa, J.I.

    2006-01-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  8. Overview of the breast cancer and mammographic status in Asia and in Japan

    International Nuclear Information System (INIS)

    Endo, Tokiko

    2017-01-01

    Breast cancer is the top cancer in women both in the most Western and Asian countries. The incidence of the breast cancer is lower in Asia than in the western countries, but, is increasing due to increase life expectancy, increase urbanization and adoption of western life styles. Mammography screening is the only method that has proved to be effective and cost-effective. In Japan, the mammographic breast cancer screening was started in 2004, and quality control has been done by the Japan Central Organization on Quality Assurance of Breast Cancer Screening, which is consisted with nine major societies concerning the breast cancer diagnosis and treatment. The Japanese Society of Radiological Technology and the Japan Society of Medical Physics are the members of this organization and play impotent roles in mammographic quality control. The main activities of this organization are the education for radiological technicians and interpreters and the insurance the mammographic facilities meet radiation dose and image quality standard. I'll introduce the state of the breast cancer and the efforts for breast cancer screening in Asian countries and in Japan

  9. Development of terminology for mammographic techniques for radiological technologists.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Tsuji, Shintaro; Nishimoto, Naoki; Uesugi, Masahito; Muto, Hiroshi; Ohba, Hisateru; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2011-07-01

    We are developing a mammographic ontology to share knowledge of the mammographic domain for radiologic technologists, with the aim of improving mammographic techniques. As a first step in constructing the ontology, we used mammography reference books to establish mammographic terminology for identifying currently available knowledge. This study proceeded in three steps: (1) determination of the domain and scope of the terminology, (2) lexical extraction, and (3) construction of hierarchical structures. We extracted terms mainly from three reference books and constructed the hierarchical structures manually. We compared features of the terms extracted from the three reference books. We constructed a terminology consisting of 440 subclasses grouped into 19 top-level classes: anatomic entity, image quality factor, findings, material, risk, breast, histological classification of breast tumors, role, foreign body, mammographic technique, physics, purpose of mammography examination, explanation of mammography examination, image development, abbreviation, quality control, equipment, interpretation, and evaluation of clinical imaging. The number of terms that occurred in the subclasses varied depending on which reference book was used. We developed a terminology of mammographic techniques for radiologic technologists consisting of 440 terms.

  10. Significant inhibitory impact of dibenzyl trisulfide and extracts of Petiveria alliacea on the activities of major drug-metabolizing enzymes in vitro: An assessment of the potential for medicinal plant-drug interactions.

    Science.gov (United States)

    Murray, J; Picking, D; Lamm, A; McKenzie, J; Hartley, S; Watson, C; Williams, L; Lowe, H; Delgoda, R

    2016-06-01

    Dibenzyl trisulfide (DTS) is the major active ingredient expressed in Petiveria alliacea L., a shrub widely used for a range of conditions, such as, arthritis, asthma and cancer. Given its use alone and concomitantly with prescription medicines, we undertook to investigate its impact on the activities of important drug metabolizing enzymes, the cytochromes P450 (CYP), a key family of enzymes involved in many adverse drug reactions. DTS and seven standardized extracts from the plant were assessed for their impact on the activities of CYPs 1A2, 2C19, 2C9, 2D6 and 3A4 on a fluorometric assay. DTS revealed significant impact against the activities of CYPs 1A2, 2C19 and 3A4 with IC50 values of 1.9, 4.0 and 3.2μM, respectively, which are equivalent to known standard inhibitors of these enzymes (furafylline, and tranylcypromine), and the most potent interaction with CYP1A2 displayed irreversible enzyme kinetics. The root extract, drawn with 96% ethanol (containing 2.4% DTS), displayed IC50 values of 5.6, 3.9 and 4.2μg/mL respectively, against the same isoforms, CYPs 1A2, 2C19 and 3A4. These investigations identify DTS as a valuable CYP inhibitor and P. alliacea as a candidate plant worthy of clinical trials to confirm the conclusions that extracts yielding high DTS may lead to clinically relevant drug interactions, whilst extracts yielding low levels of DTS, such as aqueous extracts, are unlikely to cause adverse herb-drug interactions. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Computational prediction of binding affinity for CYP1A2-ligand complexes using empirical free energy calculations

    DEFF Research Database (Denmark)

    Poongavanam, Vasanthanathan; Olsen, Lars; Jørgensen, Flemming Steen

    2010-01-01

    , and methods based on statistical mechanics. In the present investigation, we started from an LIE model to predict the binding free energy of structurally diverse compounds of cytochrome P450 1A2 ligands, one of the important human metabolizing isoforms of the cytochrome P450 family. The data set includes both...... substrates and inhibitors. It appears that the electrostatic contribution to the binding free energy becomes negligible in this particular protein and a simple empirical model was derived, based on a training set of eight compounds. The root mean square error for the training set was 3.7 kJ/mol. Subsequent......Predicting binding affinities for receptor-ligand complexes is still one of the challenging processes in computational structure-based ligand design. Many computational methods have been developed to achieve this goal, such as docking and scoring methods, the linear interaction energy (LIE) method...

  12. Hepatic Cyp1a2 Expression Reduction during Inflammation Elicited in a Rat Model of Intermittent Hypoxia

    Directory of Open Access Journals (Sweden)

    Li-Xia Shi

    2017-01-01

    Conclusions: These results indicate a decrease in expression of hepatic CYPs and their regulator GR in rats exposed to IH. Therefore, this should be noted for patients on medication, especially those on drugs metabolized via the hepatic system, and close attention should be paid to the liver function of patients with OSA-associated IH.

  13. Glutathione S-transferase M1 and T1, CYP1A2-2467T/delT ...

    African Journals Online (AJOL)

    Bв€™chir Fatma

    2012-06-16

    Jun 16, 2012 ... tion of tobacco carcinogens and may therefore affect lung cancer risk. In order to assess ... E-mail address: bchirfatma@hotmail.fr (B. Fatma). Peer review under .... rette smoked and the mean daily cigarettes smoked.

  14. Mammographic image restoration using maximum entropy deconvolution

    International Nuclear Information System (INIS)

    Jannetta, A; Jackson, J C; Kotre, C J; Birch, I P; Robson, K J; Padgett, R

    2004-01-01

    An image restoration approach based on a Bayesian maximum entropy method (MEM) has been applied to a radiological image deconvolution problem, that of reduction of geometric blurring in magnification mammography. The aim of the work is to demonstrate an improvement in image spatial resolution in realistic noisy radiological images with no associated penalty in terms of reduction in the signal-to-noise ratio perceived by the observer. Images of the TORMAM mammographic image quality phantom were recorded using the standard magnification settings of 1.8 magnification/fine focus and also at 1.8 magnification/broad focus and 3.0 magnification/fine focus; the latter two arrangements would normally give rise to unacceptable geometric blurring. Measured point-spread functions were used in conjunction with the MEM image processing to de-blur these images. The results are presented as comparative images of phantom test features and as observer scores for the raw and processed images. Visualization of high resolution features and the total image scores for the test phantom were improved by the application of the MEM processing. It is argued that this successful demonstration of image de-blurring in noisy radiological images offers the possibility of weakening the link between focal spot size and geometric blurring in radiology, thus opening up new approaches to system optimization

  15. Mammographic features of isolated tuberculous mastitis

    International Nuclear Information System (INIS)

    Al-Marri, Mohammed R.; Aref, Essam; Omar, Ahamed J.

    2005-01-01

    To present the mammography findings in 8 patients with tuberculosis (TB) of the breast, with a review of the literature. This study is a retrospective data collection. Each chart with confirmed breast TB based on bacteriology or pathologic findings was analyzed for clinical presentation, gender, nationality, demographic data, prior history of TB, investigation, management, mammographic findings and ultrasound, when available. Mammograms were reviewed by 2 consultant radiologists without knowing the previous diagnosis or the nature of the study. The study was carried out at The State Tuberculosis Registry and Radiology Department, Hamad General Hospital, State of Qatar, from 1990 to 2002. Out of 13 females with TB mastitis, only 8 cases had mammograms preoperatively. The incidence of breast TB in Qatar is rare (1/1000 mammograms per year). Three types of TB mastitis were identified in our study; the nodular (50%), the diffuse (37.5%) of which 77% were limited to one sector of the breast and the sclerosing (12.5%) mastitis. Three patients (43%) were reported as carcinoma. Although mammography identified 3 types of TB, it was not helpful in differentiating TB from carcinoma of the breast. However, the careful evaluation of the degree of density and trabecular thickening of the mass in relation to it size might reduce the number of false positive cases of carcinoma diagnosed with mammograms. Biopsy specimen remains the best diagnostic tool in TB mastitis. (author)

  16. Mammographic features of isolated tuberculous mastitis.

    Science.gov (United States)

    Al-Marri, Mohammed R; Aref, Essam; Omar, Ahamed J

    2005-04-01

    To present the mammography findings in 8 patients with tuberculosis (TB) of the breast, with a review of the literature. This study is a retrospective data collection. Each chart with confirmed breast TB based on bacteriology or pathologic findings was analyzed for clinical presentation, gender, nationality, demographic data, prior history of TB, investigation, management, mammographic findings and ultrasound, when available. Mammograms were reviewed by 2 consultant radiologists without knowing the previous diagnosis or the nature of the study. The study was carried out at The State Tuberculosis Registry and Radiology Department, Hamad General Hospital, State of Qatar, from 1990 to 2002. Out of 13 females with TB mastitis, only 8 cases had mammograms preoperatively. The incidence of breast TB in Qatar is rare (1/1000 mammograms per year). Three types of TB mastitis were identified in our study; the nodular (50%), the diffuse (37.5%) of which 77% were limited to one sector of the breast and the sclerosing (12.5%) mastitis. Three patients (43%) were reported as carcinoma. Although mammography identified 3 types of TB, it was not helpful in differentiating TB from carcinoma of the breast. However, the careful evaluation of the degree of density and trabecular thickening of the mass in relation to it size might reduce the number of false positive cases of carcinoma diagnosed with mammograms. Biopsy specimen remains the best diagnostic tool in TB mastitis.

  17. Circumscribed breast carcinoma: Mammographic and sonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Lee, Yul; Park, Ki Soon; Lee, Ke Sook [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1992-03-15

    Circumscribe breast cancer is a well demarcated mass with or without a lobulated border simulating a benign tumor like fibroadenoma on mammography or breast US and is reported as approximate 10% of the incidence among primary breast carcinoma(1.2). Pathologically medullary, colloid, papillary, intraductal and rarely invasive ductal carcinomas are included in this group which show the less intense desmoplastic reaction than the scirrhous type cancer, resulting in the most favorable prognosis of all carcinoma of the breast. Among 214 primary breast carcinoma during the past 8 years, we experienced 6 case of pathologically proven circumscribed breast cancer(2 cases of medullary carcinoma, 1 of colloid carcinoma, 1 of intracystic papillary carcinoma, 2 of comedo type intraductal carcinoma). Clinically 2 cases showed bloody nipple discharge from one hole of a unilateral nipple orifice. Mammography showed a well circumscribed nodule with or without partial lobular contour and no pathologic calcification. Breast sonographic findings were a well defined heterogeneous hypoechoic nodule with weak posterior acoustic enhancement. Characteristically a thin dilated lactiferous duct between the mass and the nipple on US could be detected in 2 cases which clinically was accompanied by bloody nipple discharge. Although the mammographic criteria is promising as benign tumor, the possibility of circumscribed as benign tumor, the possibility of circumscribed breast carcinoma must be considered in heterogeneous hypoechoic nodule with weak posterior acoustic enhancement in US, especially in the presence of a dilated lactiferous duct between the mass and the nipple with bloody nipple discharge.

  18. Red clover-derived isoflavones and mammographic breast density: a double-blind, randomized, placebo-controlled trial [ISRCTN42940165

    International Nuclear Information System (INIS)

    Atkinson, Charlotte; Warren, Ruth ML; Sala, Evis; Dowsett, Mitch; Dunning, Alison M; Healey, Catherine S; Runswick, Shirley; Day, Nicholas E; Bingham, Sheila A

    2004-01-01

    Isoflavones are hypothesized to protect against breast cancer, but it is not clear whether they act as oestrogens or anti-oestrogens in breast tissue. Our aim was to determine the effects of taking a red clover-derived isoflavone supplement daily for 1 year on mammographic breast density. Effects on oestradiol, follicle-stimulating hormone (FSH), luteinizing hormone (LH), lymphocyte tyrosine kinase activity and menopausal symptoms were also assessed. A total of 205 women (age range 49–65 years) with Wolfe P2 or DY mammographic breast patterns were randomly assigned to receive either a red clover-derived isoflavone tablet (26 mg biochanin A, 16 mg formononetin, 1 mg genistein and 0.5 mg daidzein) or placebo. Change in mammographic breast density, serum oestradiol, FSH, LH, menopausal symptoms and lymphocyte tyrosine kinase activity from baseline to 12 months were assessed. A total of 177 women completed the trial. Mammographic breast density decreased in both groups but the difference between the treatment and placebo was not statistically significant. There was a significant interaction between treatment group and oestrogen receptor (ESR1) PvuII polymorphism for the change in estimated percentage breast density (mean ± standard deviation): TT isoflavone 1.4 ± 12.3% and TT placebo -9.6 ± 14.2%; CT isoflavone -5.2 ± 12.0% and CT placebo -2.8 ± 10.3%; and CC isoflavone -3.4 ± 9.7% and CC placebo -1.1 ± 9.5%. There were no statistically significant treatment effects on oestradiol, FSH, or LH (assessed only in postmenopausal women), or on lymphocyte tyrosine kinase activity. Baseline levels of menopausal symptoms were low, and there were no statistically significant treatment effects on frequency of hot flushes or other menopausal symptoms. In contrast to studies showing that conventional hormone replacement therapies increase mammographic breast density, the isoflavone supplement did not increase mammographic breast density in this population of women

  19. Fibroadenomas Frequency in uncertain mammographic lesions: Histology Correlation

    International Nuclear Information System (INIS)

    Hincapie Uribe, Ana Lucia; Patino Pacheco, Jairo H; Restrepo Mejia, Ana Lucia

    1997-01-01

    Purpose was to determine the frequency of fibroadenomas in non-palpable mammographic lesions, histologically evaluated and describe its radiological characteristics according to the type of mammographic presentation and classification. 60 (8.6%) fibroadenomas were found in 692 biopsies performed. 50% of these were mammographicaly classified as category 3 and 50% in the category 4. 66.6% of them were nodules, 20% isolated calcifications and nodules with calcifications 13.3%. fibroadenomas were 26.4% of nodules in category 3 and 18.8% of them in category 4

  20. Mammographic dose survey in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Leos [National Radiation Protection Institute, Prague (Czech Republic); Rada, Jiri [National Radiation Protection Institute, Ostrava (Czech Republic)

    2006-07-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  1. A biomechanical model of mammographic compressions.

    Science.gov (United States)

    Chung, J H; Rajagopal, V; Nielsen, P M F; Nash, M P

    2008-02-01

    A number of biomechanical models have been proposed to improve nonrigid registration techniques for multimodal breast image alignment. A deformable breast model may also be useful for overcoming difficulties in interpreting 2D X-ray projections (mammograms) of 3D volumes (breast tissues). If a deformable model could accurately predict the shape changes that breasts undergo during mammography, then the model could serve to localize suspicious masses (visible in mammograms) in the unloaded state, or in any other deformed state required for further investigations (such as biopsy or other medical imaging modalities). In this paper, we present a validation study that was conducted in order to develop a biomechanical model based on the well-established theory of continuum mechanics (finite elasticity theory with contact mechanics) and demonstrate its use for this application. Experimental studies using gel phantoms were conducted to test the accuracy in predicting mammographic-like deformations. The material properties of the gel phantom were estimated using a nonlinear optimization process, which minimized the errors between the experimental and the model-predicted surface data by adjusting the parameter associated with the neo-Hookean constitutive relation. Two compressions (the equivalent of cranio-caudal and medio-lateral mammograms) were performed on the phantom, and the corresponding deformations were recorded using a MRI scanner. Finite element simulations were performed to mimic the experiments using the estimated material properties with appropriate boundary conditions. The simulation results matched the experimental recordings of the deformed phantom, with a sub-millimeter root-mean-square error for each compression state. Having now validated our finite element model of breast compression, the next stage is to apply the model to clinical images.

  2. Mammographic dose survey in the Czech Republic

    International Nuclear Information System (INIS)

    Novak, Leos; Rada, Jiri

    2006-01-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  3. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Energy Technology Data Exchange (ETDEWEB)

    Annovazzi, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Amendolia, S.R. [Str. Dip. di Matematica e Fisica dell' Universita, Sassari and Sezione I.N.F.N., Pisa (Italy); Bigongiari, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Catarsi, F. [CAEN S.p.A., Viareggio-Lucca (Italy); Cesqui, F. [AMS S.p.A, Rome (Italy); Cetronio, A. [AMS S.p.A, Rome (Italy); Colombo, F. [LABEN S.p.A., Vimodrone-Milan (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Gilberti, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Lanzieri, C. [AMS S.p.A, Rome (Italy); Lavagna, S. [AMS S.p.A, Rome (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Passuello, G. [CAEN S.p.A., Viareggio-Lucca (Italy); Paternoster, G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Pieracci, M. [CAEN S.p.A., Viareggio-Lucca (Italy); Poletti, M. [LABEN S.p.A., Vimodrone-Milan (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy)]. E-mail: arnaldo.stefanini@pi.infn.it; Testa, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Venturelli, L. [AMS S.p.A, Rome (Italy)

    2007-06-11

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm{sup 2} therefore to cover the typical irradiation field used in mammography (18x24 cm{sup 2}), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  4. Mammographic profiles of women with symptomatic breast diseases ...

    African Journals Online (AJOL)

    Methods: This was a prospective descriptive analytical study of women with symptomatic breast diseases who had mammography between January 2012 and December 2016 at our health facilities. Data sheet was developed to record the patients' biodata, indication for referral, and mammographic findings. Results: During ...

  5. Mammographic and sonographic spectrum of non-puerperal mastitis

    NARCIS (Netherlands)

    M.H. Lequin (Maarten); J. van Spengler (J.); R. van Pel; C.H.J. van Eijck (Casper); H. van Overhagen (H.)

    1995-01-01

    textabstractThe goal of this study was to explore possible specific mammographic and sonographic features in women with non-puerperal mastitis (NPM), in order to make an accurate diagnosis and prevent unnecessary surgical procedures. From a group of 93 patients with NPM diagnosed between 1987 and

  6. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  7. Mammographic classification of breast lesions amongst women in ...

    African Journals Online (AJOL)

    Objectives: The study was to classify lesions identified on mammograms using Breast Imaging Reporting and Data System (BIRADS) grading method. This was in view of ascertaining the rate of occurrence of breast malignancy of the studied population. Methods: A retrospective cohort study of 416 mammographic reports of ...

  8. Mucinous carcinoma of the breast: mammographic features with histologic correlation

    International Nuclear Information System (INIS)

    Cui Chunyan; Zhang Ling; Wu Yaopan; Li Shuqin

    2011-01-01

    Objective: To correlate the mammographic findings of mucinous carcinoma with histologic features. Methods: Retrospective analysis of the mammographic and pathologic findings of 37 patients with mucinous carcinomas of the breasts was performed. Results: Mammograms of ten (52.6%) women with mucinous carcinomas showed masses with well-defined, lobu-lated margins correlating well with the pure histologic type. Thirteen (81.3%) mixed type of mucinous carcinomas demonstrated poorly defined or spiculated margins (P<0.05). Most of the pure type carcinomas were hyperdense similar to most of mixed type carcinomas (P<0.05). Of 34 mucinous carcinomas tested, there were 25 ER-positive, 29 PR-positive, 24 C-erbB-2 negative expressions with pure type carcinomas accounting for 78.9%, 89.5% and 78.9%, respectively. Conclusion: The mammographic features of pure type are different from those of mixed type of mucinous breast carcinomas. The most common mammographic appearance of pure mucinous carcinoma is a well-defined mass without calcification whereas the mixed type carcinomas have more aggressive imaging characteristics. (authors)

  9. Mammographic CAD: Correlation of regions in ipsilateral views – a ...

    African Journals Online (AJOL)

    Background. Radiologists analyse both standard mammographic views of a breast to confirm the presence of abnormalities and reduce false-positives. However, at present, no computer-aided diagnosis system uses ipsilateral mammograms to confirm the presence of suspicious features. Aim. The aim of this study was to ...

  10. Mammographer personality traits – elements of the optimal ...

    African Journals Online (AJOL)

    2014-11-07

    Nov 7, 2014 ... competency, good communication skills and the ability to limit patient anxiety and ... personality traits in mammographers in order of importance .... 1 (trust) is high, with a Cronbach's alpha of 0.911 and inter- item reliability ...

  11. Mammographic Findings after Intraoperative Radiotherapy of the Breast

    International Nuclear Information System (INIS)

    Rivera, R.; Holmes, D.R.; Smith-Bronstein, V.S.; Villegas-Mendez, S.; Rayhanabad, J.; Sheth, P.; Rashtian, A.

    2012-01-01

    Intraoperative Radiotherapy (IORT) is a form of accelerated partial breast radiation that has been shown to be equivalent to conventional whole breast external beam radiotherapy (EBRT) in terms of local cancer control. However, questions have been raised about the potential of f IORT to produce breast parenchymal changes that could interfere with mammographic surveillance of cancer recurrence. The purpose of this study was to identify, quantify, and compare the mammographic findings of patients who received IORT and EBRT in a prospective, randomized controlled clinical trial of women with early stage invasive breast cancer undergoing breast conserving therapy between July 2005 and December 2009. Treatment groups were compared with regard to the 1, 2 and 4-year incidence of 6 post-operative mammographic findings: architectural distortion, skin thickening, skin retraction, calcifications, fat necrosis, and mass density. Blinded review of 90 sets of mammograms of 15 IORT and 16 EBRT patients demonstrated a higher incidence of fat necrosis among IORT recipients at years 1, 2, and 4. However, none of the subjects were judged to have suspicious mammogram findings and fat necrosis did not interfere with mammographic interpretation.

  12. Controlled exstirpation of clinically occult but mammographically suspicious findings

    Energy Technology Data Exchange (ETDEWEB)

    Grosse-Vorholt, R

    1981-03-01

    Breast-volume, size and mammographical findings near the chest wall have a great influence on the excision for histological examination. The excision should be done as an controled excision by preoperative marking with a mixture of blue colour and contrast-medium followed by an intraoperative radiography of the exstirpated tissue. We reached in 30 cases a sure excision without any postoperative complications.

  13. Overdiagnosis in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Puliti, Donella; Duffy, Stephen W; Miccinesi, Guido

    2012-01-01

    Overdiagnosis, the detection through screening of a breast cancer that would never have been identified in the lifetime of the woman, is an adverse outcome of screening. We aimed to determine an estimate range for overdiagnosis of breast cancer in European mammographic service screening programmes....

  14. COMBINED MAMMOGRAPHIC AND SONOGRAPHIC EVALUATION OF PALPABLE BREAST MASSES

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-10-01

    Full Text Available BACKGROUND Breast diseases are common in females. In developing countries like India, females are unaware of breast pathologies hence they are detected usually in advanced stages. We have studied 100 patients of palpable breast masses presenting to our department and evaluate the role of combined mammographic and sonographic imaging in patients with palpable abnormalities of the breast, which help in decision making by clinician as to lesion go for biopsy or follow up. MATERIALS AND METHODS The study was conducted at Department of Radiodiagnosis J. L.N. Medical College & Associated Groups of Hospitals, Ajmer. We included women equal to or more than 30 years referred to this centre with palpable abnormalities of breast during a period from March 2015 to August 2016. All these women underwent a combined mammographic and sonographic evaluation of breast. RESULTS 50 (50% of the 100 palpable abnormalities had benign assessment, 30 (60% of the benign lesions were visible both on mammography and sonography; 18 (36% of the 50 benign lesions were mammographically occult and identified at sonographic evaluation. 2 lesion was sonographically occult (4% and visualized on mammography. In 14 (14% of the 100 cases, imaging evaluation resulted in a suspicious assessment and all these lesions underwent biopsy and 4 were diagnosed as having malignancy. 36(36% of the 100 palpable abnormalities had negative imaging assessment finding: of these 14 patients underwent biopsy and all had benign findings. The sensitivity and negative predictive value for combined mammographic and sonographic assessment were 100%; the specificity was 78.26%. CONCLUSION Combined use of mammography and sonography plays an important role in the management of palpable breast lesions. It characterizes the palpable mass lesion, avoids unnecessary interventions in which imaging findings are unequivocally benign. Negative findings on combined mammographic and sonographic imaging have very high

  15. Characterization of mammographic masses based on level set segmentation with new image features and patient information

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan Heangping; Ge Jun; Hadjiiski, Lubomir; Helvie, Mark A.; Nees, Alexis; Wu Yita; Wei Jun; Zhou Chuan; Zhang Yiheng; Cui Jing

    2008-01-01

    Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A z value of 0.83±0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A z values were 0.85±0.01 and 0.87±0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening

  16. Body mass index and participation in organized mammographic screening

    DEFF Research Database (Denmark)

    Hellmann, Sophie Sell; Njor, Sisse Helle; Lynge, Elsebeth

    2015-01-01

    BACKGROUND: Breast cancer is the leading cancer among women, and early diagnosis is essential for future prognosis. Evidence from mainly cross-sectional US studies with self-reported exposure and outcome found positive association of body mass index (BMI) with non-participation in mammographic...... with normal weight. This association was limited to postmenopausal women (Wald test p = 0.08), with enhanced non-participation in underweight (2.83: 1.52-5.27) and obese women of class II and III (1.84: 1.15-2.95; 2.47: 1.20-5.06) as compared to normal weight postmenopausal women. There was no effect...... modification by HT, previous screening participation, or morbidities, besides suggestive evidence of enhanced non-participation in diabetic overweight and obese women. CONCLUSIONS: Underweight and very obese postmenopausal women were significantly less likely to participate in mammographic screening than women...

  17. Mammographic and sonographic features of fat necrosis of the breast

    International Nuclear Information System (INIS)

    Upadhyaya, Vidya S; Uppoor, Raghuraj; Shetty, Lathika

    2013-01-01

    Imaging features of fat necrosis vary depending on its stage of evolution and can mimic malignancy in late stages. Imaging may suffice to differentiate fat necrosis in the early stages from malignancy and thus avoid unnecessary biopsy. In this pictorial essay, we present combination of benign features in mammography and/or ultrasonography (USG) that can lead to imaging diagnosis of fat necrosis. The follow-up imaging features of fat necrosis which mirror its pathophysiological evolution have also been demonstrated. To summarize, in the appropriate clinical setting, no mammographic features suspicious for malignancy should be present. When the typical mammographic features are not present, USG can aid with the diagnosis and follow up USG can confirm it

  18. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  19. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  20. Agreement of mammographic measures of volumetric breast density to MRI.

    Science.gov (United States)

    Wang, Jeff; Azziz, Ania; Fan, Bo; Malkov, Serghei; Klifa, Catherine; Newitt, David; Yitta, Silaja; Hylton, Nola; Kerlikowske, Karla; Shepherd, John A

    2013-01-01

    Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  1. Mammographic screening practices among Chinese-Australian women.

    Science.gov (United States)

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-03-01

    To report mammographic screening practice among Chinese-Australian women, and to examine the relationship between demographic characteristics, acculturation factors (English proficiency and length of stay in Australia), cultural beliefs, and having a mammogram as recommended. Cross-sectional and descriptive. The study was conducted in 2009 in Sydney, Australia. Of 988 Chinese-Australian women over 18 years of age invited to participate in the study, 785 (79%) completed and returned the questionnaire. Of these women, 320 (40.8%) were in the target age range of 50 to 69 years. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was used as a data collection instrument. Analysis included descriptive statistics, bivariate analysis using chi-square and t tests, and logistic regression. Of the 320 women in the targeted age range of 50 to 69 years, 238 (74.4%) had a mammogram as recommended biannually. Being married-de facto, in the 60 to 69 age group, and speaking Cantonese at home were positively associated with women's mammographic screening practice. However, no statistically significant differences in acculturation factors and having a mammogram as recommended were found. In terms of CBCSB score, women who had mammograms as recommended had more positive attitudes toward health checkups and perceived fewer barriers to mammographic screening. Effort should be focused on specific subgroups of Chinese-Australian women in order to fully understand the barriers involved in participating in mammographic screening. Nurses can use the findings from the present study to design culturally sensitive breast cancer screening programs to encourage women's participation in mammography. © 2011 Sigma Theta Tau International.

  2. Mammographic density measurements are not affected by mammography system.

    Science.gov (United States)

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F

    2015-01-01

    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  3. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  4. The clinical and mammographic features of plasma cell mastitis

    International Nuclear Information System (INIS)

    Wu Xiurong; Luo Xiaohua; Yu Xuming; Zhong Shan; Huang Yufan; Wu Xinyi; Lin Yubin

    2007-01-01

    Objective: To investigate the clinical and mammographic features of plasma cell mastitis. Methods: Twenty-five patients (28 lesions) with histologically confirmed plasma cell mastitis, aged from 26 to 70 years (mean age 41 years), were examined with X-ray mammography. The clinical manifestations and imaging features were retrospectively reviewed. Results: No case was in lactation. The painful irregular masses, ranged from 1.3 to 8cm in size, were found in 22 patients, while 3 patients with acute episode. Recurrent episodes of breast masses were noted in 4 patients. Based on the mammographic appearances, the plasma cell mastitis were classified as the following four types: inflammation-like type (2/28), ductal ectasia type (3/28), focal infiltration type (10/28) and nodular type (13/28). The valuable radiographic signs: (1) An asymmetrically increased density along the lactiferous duct with a flame-like appearance, inhomogeneous low density tubular structures and scattered stick-shape calcifications. (2) Architectural distortion and oil cysts formation in adjacent area, (3) Subareolar ductal ectasia. Conclusions: The clinical and mammographic characteristics of plasma cell mastitis are critical to avoiding unnecessary surgery. Histopathological result is needed for the diagnosis in patients highly suspected of malignancy. (authors)

  5. Identification of simulated microcalcifications in white noise and mammographic backgrounds

    International Nuclear Information System (INIS)

    Reiser, Ingrid; Nishikawa, Robert M.

    2006-01-01

    This work investigates human performance in discriminating between differently shaped simulated microcalcifications embedded in white noise or mammographic backgrounds. Human performance was determined through two alternative forced-choice (2-AFC) experiments. The signals used were computer-generated simple shapes that were designed such that they had equal signal energy. This assured equal detectability. For experiments involving mammographic backgrounds, signals were blurred to account for the imaging system modulation transfer function (MTF). White noise backgrounds were computer generated; anatomic background patches were extracted from normal mammograms. We compared human performance levels as a function of signal energy in the expected difference template. In the discrimination task, the expected difference template is the difference between the two signals shown. In white noise backgrounds, human performance in the discrimination task was degraded compared to the detection task. In mammographic backgrounds, human performance in the discrimination task exceeded that of the detection task. This indicates that human observers do not follow the optimum decision strategy of correlating the expected signal template with the image. Human observer performance was qualitatively reproduced by non-prewhitening with eye filter (NPWE) model observer calculations, in which spatial uncertainty was explicitly included by shifting the locations of the expected difference templates. The results indicate that human strategy in the discrimination task may be to match individual signal templates with the image individually, rather than to perform template matching between the expected difference template and the image

  6. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings.

  7. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    International Nuclear Information System (INIS)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings

  8. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  9. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Broeders, Mireille; Moss, Sue; Nyström, Lennarth

    2012-01-01

    To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data.......To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data....

  10. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  11. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  12. Improved mammographic interpretation of masses using computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Leichter, I. [Dept. of Electro-Optics, Jerusalem College of Technology (Israel); Fields, S.; Novak, B. [Dept. of Radiology, Hadassah University Hospital, Mt. Scopus Jerusalem (Israel); Nirel, R. [Dept. of Statistics, Hebrew University of Jerusalem, Mt. Scopus, Jerusalem (Israel); Bamberger, P. [Dept. of Electronics, Jerusalem College of Technology, Jerusalem (Israel); Lederman, R. [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Buchbinder, S. [Department of Radiology, Montefiore Medical Center, University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States)

    2000-02-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A{sub z}) increased significantly (p < 0.001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A{sub z} for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that

  13. From a mammographic station to a federal mammalogic center

    International Nuclear Information System (INIS)

    Rozhkova, N.I.; Kharchenko, V.P.

    2000-01-01

    Using the history of mammalogy development in Russian Scientific Center of Roentgenoradiology of the Ministry of Public Health of Russian Federation as an example the evolution of above trend in Russia is retraced. It is shown that during 20 years (from 1978) in the department of mammary gland diseases diagnosis of the Centre the rational, economically expedient and highly efficient diagnostic system for combined examination of mammary glands is developing and introducing in medical prophylactic installations of Russian Federation. This system consists of women selection for risk group, stage of additional examination in special mammographic rooms and therapeutic stage. Directions of researches of the Centre (technical, organizational-methodical, medical) are considered [ru

  14. Quality Control and Dosimetry in Mammographic Units in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Flioni-Vysa, A; Xenofos, S; Stamatelatos, E; Georgolopoulou, P [Department of Medical Physics, Saint Savvas Hospital, 171 Alexandras Avenue, Athens 115 22, (Greece)

    1994-12-31

    Quality control measurements have been carried out on 29 mammographic units. It was found that a large percentage of users obtained Optical Densities outside the recommended values. Resolution under routine conditions was below the limit of 14 lp/mm in about 50% of the units. The skin entrance dose was in a few cases in excess of 10 micro Gray, but the mean value was well below this upper limit. Analysis of the results obtained has indicated that proper calibration of kilo voltage panel indications and automatic exposure control systems is of outmost importance and should be performed regularly. (authors). 11 refs, 2 figs 3 tabs.

  15. Classification of mammographic masses using geometric symmetry and fractal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Guo Qi; Ruiz, V.F. [Cybernetics, School of Systems Engineering, Univ. of Reading (United Kingdom); Shao Jiaqing [Dept. of Electronics, Univ. of Kent (United Kingdom); Guo Falei [WanDe Industrial Engineering Co. (China)

    2007-06-15

    In this paper, we propose a fuzzy symmetry measure based on geometrical operations to characterise shape irregularity of mammographic mass lesion. Group theory, a powerful tool in the investigation of geometric transformation, is employed in our work to define and describe the underlying mathematical relations. We investigate the usefulness of fuzzy symmetry measure in combination with fractal analysis for classification of masses. Comparative studies show that fuzzy symmetry measure is useful for shape characterisation of mass lesions and is a good complementary feature for benign-versus-malignant classification of masses. (orig.)

  16. Barriers and facillitators to compliance with routine mammographic screening

    International Nuclear Information System (INIS)

    Kessler, H.B.; Rimer, B.; Keintz, M.K.; Myers, R.E.; Engstrom, P.F.

    1988-01-01

    Six hundred one randomly selected women were interviewed to determine their reasons for compliance or noncompliance with free HMO-sponsored mammographic examinations. Noncompliers were significantly more likely to believe mammograms are unnecessary without symptoms, too much trouble, or inconvenient and to perceive their physicians as not recommending mammograms. Compliers were more likely to believe that early breast cancer can be cured and to recognize that breast screening is for asymptomatic individuals. When cost is eliminated as a barrier to screening, a variety of socioeconomic, psychological, and access barriers are exposed. Radiologists must be cognizant of these factors in planning and participating in breast cancer screening programs

  17. Mammographic follow-up after conservation therapy for breast cancer

    International Nuclear Information System (INIS)

    Gu Yajia; Xiao Qin; Zheng Xiaojing; Wu Jiong; Chen Jiayi; Gu Rongfeng; Feng Xiaoyuan

    2006-01-01

    Objective: To recognize the mammographic changes after conservation therapy for breast carcinoma. Methods: A total of 139 follow-up mammographic examinations in 85 cases were studied during the period between 1999 and 2004. Mammography was performed at intervals of 6 months for the first 2 years, then annually. Attention was paid to mammographic change patterns of conservation therapy for breast carcinoma, including breast edema, skin thickening, architectural disturbance, asymmetric density, architectural distortion retraction, and calcifications. SPSS version 11.0 for windows was used to perform all statistical tests. Kruskal-Wallis H test was used for calculating the overall statistical differences between difference periods. Categorical data were expressed as percentages and analyzed by using the X 2 test. The age of the patients ranged from 25 to 63 years (mediate, 44 years old). The time of follow-up observation ranged from 1 week to 72 months. Results: Two cases were normal on mammograms. High proportion of abnormal mammography was seen in the period of 12 month (40.3%, 56/139) and 24 month (21.6%, 30/139), respectively. Various findings appeared in various periods and the difference was statistically significant(X 2 =30.998, v=6, P=0.001). Mild edema appeared in the first 3 years. Moderately severe or marked breast edema may be present between 6 months to 12 months, then slowly resolved. The appearance and disappearance of skin thickening were similar to the process of breast edema. The changes of architectural disturbance did not correlate with time (X 2 =8.634, P>0.05), but on sequential mammograms for same patient, the extent of architectural disturbance relieved over time (17/19). Asymmetric density was found in only 5 patients, and disappeared in later period of follow-up in 3. Architectural distortion retraction got more and more obvious with time, and kept stable after certain period of time. Calcifications were shown in 2 patients, including 1

  18. Towards an automatic tool for resolution evaluation of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira, J. E. E. [FUMEC, Av. Alfonso Pena 3880, CEP 30130-009 Belo Horizonte - MG (Brazil); Nogueira, M. S., E-mail: juliae@fumec.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901, Belo Horizonte - MG (Brazil)

    2014-08-15

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  19. Towards an automatic tool for resolution evaluation of mammographic images

    International Nuclear Information System (INIS)

    De Oliveira, J. E. E.; Nogueira, M. S.

    2014-08-01

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  20. Glycemic index, glycemic load and mammographic breast density: the EPIC Florence longitudinal study.

    Directory of Open Access Journals (Sweden)

    Giovanna Masala

    Full Text Available A few studies have evaluated the association between diet and mammographic breast density (MBD and results are inconsistent. MBD, a well-recognized risk factor for breast cancer, has been proposed as a marker of cumulative exposure to hormones and growth factors. Diets with a high glycemic index (GI or glycemic load (GL may increase breast cancer risk, via an effect on the insulin-like growth factor axis. We have investigated the association between carbohydrate intake, GI, GL and MBD in a prospective study. We identified a large series of women, in the frame of the EPIC-Florence cohort, with a mammogram taken five years after enrolment, when detailed information on dietary and lifestyle habits and anthropometric measurements had been collected. Mammograms have been retrieved (1,668, 83% and MBD assessed according to Wolfe's classification. We compared women with high MBD (P2+DY Wolfe's categories with those with low MBD (N1+P1 through logistic models adjusted for age, education, body mass index, menopause, number of children, breast feeding, physical activity, non-alcohol energy, fibers, saturated fat and alcohol. A direct association between GL and high MBD emerged in the highest quintile of intake in comparison with the lowest quintile (OR = 1.73, 95%CI 1.13-2.67, p for trend = 0.048 while no association with glycemic index was evident. These results were confirmed after exclusion of women reporting to be on a diet or affected with diabetes, and when Hormone Replacement Therapy at the date of mammographic examination used to assess MBD was considered. The effect was particularly evident among leaner women, although no interaction was found. A positive association was suggested for increasing simple sugar and total carbohydrates intakes limited to the highest quintiles. In this Italian population we observed an association between glycemic load, total and rapidly absorbed carbohydrates and high MBD. These novel results warrant further

  1. CADx of mammographic masses and clustered microcalcifications: A review

    International Nuclear Information System (INIS)

    Elter, Matthias; Horsch, Alexander

    2009-01-01

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  2. CADx of mammographic masses and clustered microcalcifications: A review

    Energy Technology Data Exchange (ETDEWEB)

    Elter, Matthias; Horsch, Alexander [Fraunhofer Institute for Integrated Circuits (IIS), Am Wolfsmantel 33, 91058 Erlangen (Germany); Institute for Medical Statistics and Epidemiology, TU Muenchen, Ismaninger Strasse 22, 81675 Muenchen (Germany) and Department of Computer Science, University of Tromsoe Breivika, N-9037 Tromsoe (Norway)

    2009-06-15

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  3. Feature extraction from mammographic images using fast marching methods

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.

    2002-01-01

    Features extraction from medical images represents a fundamental step for shape recognition and diagnostic support. The present work faces the problem of the detection of large features, such as massive lesions and organ contours, from mammographic images. The regions of interest are often characterized by an average grayness intensity that is different from the surrounding. In most cases, however, the desired features cannot be extracted by simple gray level thresholding, because of image noise and non-uniform density of the surrounding tissue. In this work, edge detection is achieved through the fast marching method (Level Set Methods and Fast Marching Methods, Cambridge University Press, Cambridge, 1999), which is based on the theory of interface evolution. Starting from a seed point in the shape of interest, a front is generated which evolves according to an appropriate speed function. Such function is expressed in terms of geometric properties of the evolving interface and of image properties, and should become zero when the front reaches the desired boundary. Some examples of application of such method to mammographic images from the CALMA database (Nucl. Instr. and Meth. A 460 (2001) 107) are presented here and discussed

  4. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  5. Collaborating with Mammographers to Address Their Work-Related Musculoskeletal Discomfort

    Science.gov (United States)

    Sommerich, Carolyn M.; Lavender, Steven A.; Evans, Kevin D.; Sanders, Elizabeth; Joines, Sharon; Lamar, Sabrina; Umar, Radin Zaid Radin; Yen, Wei-Ting; Park, SangHyun

    2017-01-01

    Mammographers are an understudied group of healthcare workers, yet the prevalence of musculoskeletal (MSK) symptoms in mammographers appears to be elevated, similar to many occupations in healthcare. In this study, we used a participatory approach to identify needs and opportunities for developing interventions to reduce mammographers’ exposures to risk factors that lead to development of MSK symptoms. In this paper, we present a number of those needs and several intervention concepts along with evaluations of those concepts from experienced mammographers. We include findings from a preliminary field test of a novel intervention concept to reduce the need to adopt awkward postures while positioning patients for a screening or diagnostic mammogram. PMID:26794257

  6. Evaluation of the Effects of S-Allyl-L-cysteine, S-Methyl-L-cysteine, trans-S-1-Propenyl-L-cysteine, and Their N-Acetylated and S-Oxidized Metabolites on Human CYP Activities.

    Science.gov (United States)

    Amano, Hirotaka; Kazamori, Daichi; Itoh, Kenji

    2016-01-01

    Three major organosulfur compounds of aged garlic extract, S-allyl-L-cysteine (SAC), S-methyl-L-cysteine (SMC), and trans-S-1-propenyl-L-cysteine (S1PC), were examined for their effects on the activities of five major isoforms of human CYP enzymes: CYP1A2, 2C9, 2C19, 2D6, and 3A4. The metabolite formation from probe substrates for the CYP isoforms was examined in human liver microsomes in the presence of organosulfur compounds at 0.01-1 mM by using liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Allicin, a major component of garlic, inhibited CYP1A2 and CYP3A4 activity by 21-45% at 0.03 mM. In contrast, a CYP2C9-catalyzed reaction was enhanced by up to 1.9 times in the presence of allicin at 0.003-0.3 mM. SAC, SMC, and S1PC had no effect on the activities of the five isoforms, except that S1PC inhibited CYP3A4-catalyzed midazolam 1'-hydroxylation by 31% at 1 mM. The N-acetylated metabolites of the three compounds inhibited the activities of several isoforms to a varying degree at 1 mM. N-Acetyl-S-allyl-L-cysteine and N-acetyl-S-methyl-L-cysteine inhibited the reactions catalyzed by CYP2D6 and CYP1A2, by 19 and 26%, respectively, whereas trans-N-acetyl-S-1-propenyl-L-cysteine showed weak to moderate inhibition (19-49%) of CYP1A2, 2C19, 2D6, and 3A4 activities. On the other hand, both the N-acetylated and S-oxidized metabolites of SAC, SMC, and S1PC had little effect on the reactions catalyzed by the five isoforms. These results indicated that SAC, SMC, and S1PC have little potential to cause drug-drug interaction due to CYP inhibition or activation in vivo, as judged by their minimal effects (IC 50 >1 mM) on the activities of five major isoforms of human CYP in vitro.

  7. Dietary effect on mixed function P450 1A2 activity assayed by estimation of caffeine metabolism in man.

    Science.gov (United States)

    Kall, M A; Clausen, J

    1995-10-01

    Two studies were performed in order to evaluate cytochrome P450 1A2 mediated caffeine metabolism during different nutritional conditions. 1. In the first study, 23 healthy male non-smokers, mean age 25, changed from a customary mixed diet to a standard diet in 6 days. The 6 day's standard diet was based on bread, potatoes, rice and boiled meat. Thus, broccoli, cabbage and other cruciferous vegetables, spinach, leeks, onion, parsley, grapefruit, toasted bread, fried and charcoal grilled food, smoked fish and meat, ham and sausages were avoided. 2. In the second study, 33 healthy non-smoking subjects, 24 men and nine women mean age 25 years, volunteered. The study was designed to compare a customary home dietary period with the 6 day period of low dietary P450 induction and with a 5 day supplementary dietary period, i.e. ingestion of known dietary inducers. None of the women were using oral contraceptives or were pregnant during the experimental period. In the period of diet supplementation, the volunteers received charcoal grilled hamburger as a supplement to the standard low induction diet for lunch for 5 days. The hamburgers were made with 150 g beef (18-20% fat) and were grilled on charcoal for 10 min on each side until they were 'well done'. In the present study P450 1A2 activity was estimated from the caffeine metabolic ratio, the so-called CYP 1A2 index:(AFMU + 1-MX + 1-MU/ 17 -DMU) of the caffeine metabolites formed after oral ingestion of 200 mg caffeine. Urine was collected 4-8 h after caffeine ingestion in study 1 and 5 h after caffeine ingestion in study 2. In study 1 the CYP 1A2 index decreased from 4.28 +/- 0.98 in the customary home dietary period to 3.87 +/- 0.69 in the standard dietary period corresponding to 10.6% (P hamburgers as a dietary supplement, the CYP 1A2 index increased to almost the same level as in the customary home dietary period. The index increased to 4.45 +/- 1.57 in the whole group of volunteers, corresponding to a 14.1% (P < 0

  8. Evaluation of mammographic density patterns: reproducibility and concordance among scales

    Directory of Open Access Journals (Sweden)

    Garrido-Estepa Macarena

    2010-09-01

    Full Text Available Abstract Background Increased mammographic breast density is a moderate risk factor for breast cancer. Different scales have been proposed for classifying mammographic density. This study sought to assess intra-rater agreement for the most widely used scales (Wolfe, Tabár, BI-RADS and Boyd and compare them in terms of classifying mammograms as high- or low-density. Methods The study covered 3572 mammograms drawn from women included in the DDM-Spain study, carried-out in seven Spanish Autonomous Regions. Each mammogram was read by an expert radiologist and classified using the Wolfe, Tabár, BI-RADS and Boyd scales. In addition, 375 mammograms randomly selected were read a second time to estimate intra-rater agreement for each scale using the kappa statistic. Owing to the ordinal nature of the scales, weighted kappa was computed. The entire set of mammograms (3572 was used to calculate agreement among the different scales in classifying high/low-density patterns, with the kappa statistic being computed on a pair-wise basis. High density was defined as follows: percentage of dense tissue greater than 50% for the Boyd, "heterogeneously dense and extremely dense" categories for the BI-RADS, categories P2 and DY for the Wolfe, and categories IV and V for the Tabár scales. Results There was good agreement between the first and second reading, with weighted kappa values of 0.84 for Wolfe, 0.71 for Tabár, 0.90 for BI-RADS, and 0.92 for Boyd scale. Furthermore, there was substantial agreement among the different scales in classifying high- versus low-density patterns. Agreement was almost perfect between the quantitative scales, Boyd and BI-RADS, and good for those based on the observed pattern, i.e., Tabár and Wolfe (kappa 0.81. Agreement was lower when comparing a pattern-based (Wolfe or Tabár versus a quantitative-based (BI-RADS or Boyd scale. Moreover, the Wolfe and Tabár scales classified more mammograms in the high-risk group, 46.61 and 37

  9. Use of border information in the classification of mammographic masses

    International Nuclear Information System (INIS)

    Varela, C; Timp, S; Karssemeijer, N

    2006-01-01

    We are developing a new method to characterize the margin of a mammographic mass lesion to improve the classification of benign and malignant masses. Towards this goal, we designed features that measure the degree of sharpness and microlobulation of mass margins. We calculated these features in a border region of the mass defined as a thin band along the mass contour. The importance of these features in the classification of benign and malignant masses was studied in relation to existing features used for mammographic mass detection. Features were divided into three groups, each representing a different mass segment: the interior region of a mass, the border and the outer area. The interior and the outer area of a mass were characterized using contrast and spiculation measures. Classification was done in two steps. First, features representing each of the three mass segments were merged into a neural network classifier resulting in a single regional classification score for each segment. Secondly, a classifier combined the three single scores into a final output to discriminate between benign and malignant lesions. We compared the classification performance of each regional classifier and the combined classifier on a data set of 1076 biopsy proved masses (590 malignant and 486 benign) from 481 women included in the Digital Database for Screening Mammography. Receiver operating characteristic (ROC) analysis was used to evaluate the accuracy of the classifiers. The area under the ROC curve (A z ) was 0.69 for the interior mass segment, 0.76 for the border segment and 0.75 for the outer mass segment. The performance of the combined classifier was 0.81 for image-based and 0.83 for case-based evaluation. These results show that the combination of information from different mass segments is an effective approach for computer-aided characterization of mammographic masses. An advantage of this approach is that it allows the assessment of the contribution of regions rather

  10. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2000-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  11. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2001-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  12. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    1999-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  13. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2002-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  14. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density

    DEFF Research Database (Denmark)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My

    2014-01-01

    BACKGROUND: In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. PURPOSE: To compare the Danish...... dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. MATERIAL AND METHODS: The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive......, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. RESULTS...

  15. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    International Nuclear Information System (INIS)

    Guo, Q; Shao, J; Ruiz, V

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma

  16. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Q [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom); Shao, J [Department of Electronics, University of Kent at Canterbury, Kent CT2 7NT (United Kingdom); Ruiz, V [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom)

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma.

  17. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density.

    Science.gov (United States)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My; Vejborg, Ilse; Andersen, Zorana Jovanovic

    2014-06-01

    In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. To compare the Danish dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. Of the 120 women, 32 (26.7%) were classified as having fatty and 88 (73.3%) as mixed/dense mammographic density, according to Danish dichotomous classification. According to BI-RADS density classification, 12 (10.0%) women were classified as having predominantly fatty (BI-RADS code 1), 46 (38.3%) as having scattered fibroglandular (BI-RADS code 2), 57 (47.5%) as having heterogeneously dense (BI-RADS 3), and five (4.2%) as having extremely dense (BI-RADS code 4) mammographic density. The inter-rater variability assessed by weighted kappa statistic showed a substantial agreement (0.75). The dichotomous mammographic density classification system utilized in early years of Copenhagen's mammographic screening program (1991-2001) agreed well with the BI-RADS density classification system.

  18. Novel Associations between Common Breast Cancer Susceptibility Variants and Risk-Predicting Mammographic Density Measures

    OpenAIRE

    Stone, Jennifer; Thompson, Deborah J.; dos-Santos-Silva, Isabel; Scott, Christopher; Tamimi, Rulla M.; Lindstrom, Sara; Kraft, Peter; Hazra, Aditi; Li, Jingmei; Eriksson, Louise; Czene, Kamila; Hall, Per; Jensen, Matt; Cunningham, Julie; Olson, Janet E.

    2015-01-01

    Mammographic density measures adjusted for age and body mass index (BMI) are heritable predictors of breast cancer risk but few mammographic density-associated genetic variants have been identified. Using data for 10,727 women from two international consortia, we estimated associations between 77 common breast cancer susceptibility variants and absolute dense area, percent dense area and absolute non-dense area adjusted for study, age and BMI using mixed linear modeling. We found strong suppo...

  19. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Moss, S M; Nyström, L; Jonsson, H.

    2012-01-01

    Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value.......Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value....

  20. Evaluation of mammographic screen-film combinations in the clinic

    International Nuclear Information System (INIS)

    Shepard, J.

    1987-01-01

    Six commercially available mammographic film-screen combinations were evaluated in the authors department. Film speed and contrast was measured by obtaining H and D curves. Sensitivity to processing conditions was determined by analyzing changes in the H and D cures as a function of development time and temperature and by examining artifacts in a uniformly exposed film. Radiographs of a 0.5 0 star pattern show relative screen unsharpness. The speed of the film-screen combination is indicated by calculating patient dose necessary to produce optical densities of 1.5 through phantom thicknesses of 3.5 cm of acrylic. Images of a modified RMI detail phantom obtained with each film-screen combination were evaluated by 22 radiologist. Results indicate the physicians' overall preference

  1. Decision trees and integrated features for computer aided mammographic screening

    Energy Technology Data Exchange (ETDEWEB)

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  2. Decision aids for improved accuracy and standardization of mammographic diagnosis

    International Nuclear Information System (INIS)

    D'Orsi, C.J.; Getty, D.J.; Swets, J.A.; Pickett, R.M.; Seltzer, S.E.; McNeil, B.J.

    1990-01-01

    This paper examines the gains in the accuracy of mammographic diagnosis of breast cancer achievable from a pair of decision aids. Twenty-three potentially relevant perceptual features of mammograms were identified through interviews, psychometric tests, and consensus meetings with mammography specialists. Statistical analyses determined the 12 independent features that were most information diagnostically and assigned a weight to each according to its importance. Two decision aids were developed: a checklist that solicits a scale value from the radiologist for each feature and a computer program that merges those values optimally in an advisory estimate of the probability of malignancy. Six radiologists read a set of 150 cases, first in their usual way and later with the aids

  3. Mammographic compression – A need for mechanical standardization

    Energy Technology Data Exchange (ETDEWEB)

    Branderhorst, Woutjan, E-mail: w.branderhorst@amc.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands); Groot, Jerry E. de, E-mail: jerry.degroot@sigmascreening.com [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Highnam, Ralph, E-mail: ralph.highnam@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Chan, Ariane, E-mail: ariane.chan@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Böhm-Vélez, Marcela, E-mail: marcelabvelez@gmail.com [Weinstein Imaging Associates, 5850 Centre Avenue, Pittsburgh, PA 15206 (United States); Broeders, Mireille J.M., E-mail: mireille.broeders@radboudumc.nl [Radboud University Medical Center, Department for Health Evidence, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Heeten, Gerard J. den, E-mail: g.denheeten@lrcb.nl [Academic Medical Center, Department of Radiology, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Grimbergen, Cornelis A., E-mail: c.a.grimbergen@amc.uva.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands)

    2015-04-15

    Highlights: •We studied mechanical breast compression practice in two different clinical sites. •We visualized the distributions of not only the applied force but also the pressure. •The applied pressure was highly variable, both within and between the data sets. •The average applied pressure and the variation were higher for smaller breasts. •A proposal for improved individualization, by standardizing pressure, is discussed. -- Abstract: Background: A lack of consistent guidelines regarding mammographic compression has led to wide variation in its technical execution. Breast compression is accomplished by means of a compression paddle, resulting in a certain contact area between the paddle and the breast. This procedure is associated with varying levels of discomfort or pain. On current mammography systems, the only mechanical parameter available in estimating the degree of compression is the physical entity of force (daN). Recently, researchers have suggested that pressure (kPa), resulting from a specific force divided by contact area on a breast, might be a more appropriate parameter for standardization. Software has now become available which enables device-independent cross-comparisons of key mammographic metrics, such as applied compression pressure (force divided by contact area), breast density and radiation dose, between patient populations. Purpose: To compare the current compression practice in mammography between different imaging sites in the Netherlands and the United States from a mechanical point of view, and to investigate whether the compression protocols in these countries can be improved by standardization of pressure (kPa) as an objective mechanical parameter. Materials and methods: We retrospectively studied the available parameters of a set of 37,518 mammographic compressions (9188 women) from the Dutch national breast cancer screening programme (NL data set) and of another set of 7171 compressions (1851 women) from a breast imaging

  4. Male breast disease: clinical, mammographic, and ultrasonographic features

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-01-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination

  5. Male breast disease: clinical, mammographic, and ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Guenhan-Bilgen, Isil E-mail: isilbilgen@hotmail.com; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-09-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination.

  6. Development of breast phantom for quality assessment of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata, E-mail: jenifferarvelos00@gmail.com [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Biomedica; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Universidad Complutense de Madrid (UCM), Madrid (Spain). Faculdad de Medicina. Departmento de Radiologia

    2017-11-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  7. Fibrocystic disease of breast: variable mammographic and sonography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, the echogenicity was variable; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  8. Fibrocystic disease of breast: variable mammographic and sonography appearance

    International Nuclear Information System (INIS)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye

    1993-01-01

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, theechogenicity was variable ; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  9. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  10. Development of breast phantom for quality assessment of mammographic images

    International Nuclear Information System (INIS)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata; Universidade Federal de Minas Gerais; Universidad Complutense de Madrid

    2017-01-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  11. A comprehensive tool for measuring mammographic density changes over time.

    Science.gov (United States)

    Eriksson, Mikael; Li, Jingmei; Leifland, Karin; Czene, Kamila; Hall, Per

    2018-06-01

    Mammographic density is a marker of breast cancer risk and diagnostics accuracy. Density change over time is a strong proxy for response to endocrine treatment and potentially a stronger predictor of breast cancer incidence. We developed STRATUS to analyse digital and analogue images and enable automated measurements of density changes over time. Raw and processed images from the same mammogram were randomly sampled from 41,353 healthy women. Measurements from raw images (using FDA approved software iCAD) were used as templates for STRATUS to measure density on processed images through machine learning. A similar two-step design was used to train density measures in analogue images. Relative risks of breast cancer were estimated in three unique datasets. An alignment protocol was developed using images from 11,409 women to reduce non-biological variability in density change. The protocol was evaluated in 55,073 women having two regular mammography screens. Differences and variances in densities were compared before and after image alignment. The average relative risk of breast cancer in the three datasets was 1.6 [95% confidence interval (CI) 1.3-1.8] per standard deviation of percent mammographic density. The discrimination was AUC 0.62 (CI 0.60-0.64). The type of image did not significantly influence the risk associations. Alignment decreased the non-biological variability in density change and re-estimated the yearly overall percent density decrease from 1.5 to 0.9%, p density measures was not influenced by mammogram type. The alignment protocol reduced the non-biological variability between images over time. STRATUS has the potential to become a useful tool for epidemiological studies and clinical follow-up.

  12. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, Patricia, E-mail: p.mayo@titaniast.co [Titania Servicios Tecnologicos S.L., Grupo Dominguis, Apartado 46015, Valencia (Spain); Rodenas, Francisco [Departamento de Matematica Aplicada, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain); Manuel Campayo, Juan [Hospital Clinico Universitario de Valencia, Avda. Blasco Ibanez, Apartado 46017, Valencia (Spain); Verdu, Gumersido [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain)

    2010-07-21

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  13. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    International Nuclear Information System (INIS)

    Mayo, Patricia; Rodenas, Francisco; Manuel Campayo, Juan; Verdu, Gumersido

    2010-01-01

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  14. Cigarette smoking and mammographic density in the Danish Diet, Cancer and Health cohort.

    Science.gov (United States)

    Jacobsen, Katja Kemp; Lynge, Elsebeth; Vejborg, Ilse; Tjønneland, Anne; von Euler-Chelpin, My; Andersen, Zorana J

    2016-02-01

    Smoking before first childbirth increases breast cancer risk, but the biological mechanism remains unknown and may involve mammographic density (MD), one of the strongest biomarkers of breast cancer risk. We aimed to examine whether active smoking and passive smoking were associated with MD. For the 5,356 women (4,489 postmenopausal) from the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening in Copenhagen (1993-2001), we used MD (mixed/dense or fatty) assessed at the first screening after cohort entry. Active smoking (status, duration, and intensity) and passive smoking were assessed at cohort baseline (1993-1997) via questionnaire, together with other breast cancer risk factors. Logistic regression was used to estimate associations (odds ratios, 95 % confidence intervals) between smoking and MD, adjusting for confounders. Two thousand and twenty-six (56.5 %) women had mixed/dense MD, 2,214 (41.4 %) were current, and 1,175 (21.9 %) former smokers. Current smokers had significantly lower odds (0.86, 0.75-0.99) of having mixed/dense MD compared to never smokers, while former smoking was not associated with MD. Inverse association between smoking and MD was strongest in women who initiated smoking before age of 16 years (0.79, 0.64-0.96), smoked ≥15 cigarettes/day (0.83, 0.71-0.98), smoked ≥5 pack-years (0.62, 0.43-0.89), smoked >30 years (0.86, 0.75-0.99), and smoked ≥11 years before first childbirth (0.70, 0.51-0.96). Association between smoking and MD diminished after smoking cessation, with increased odds of having mixed/dense breasts in women who quit smoking >20 years ago as compared to current smokers (1.37, 1.01-1.67). There was no association between passive smoking and MD. We found an inverse association between active smoking and MD.

  15. Occupation and mammographic density: A population-based study (DDM-Occup).

    Science.gov (United States)

    García-Pérez, Javier; Pollán, Marina; Pérez-Gómez, Beatriz; González-Sánchez, Mario; Cortés Barragán, Rosa Ana; Maqueda Blasco, Jerónimo; González-Galarzo, María Carmen; Alba, Miguel Ángel; van der Haar, Rudolf; Casas, Silvia; Vicente, Cándida; Medina, Pilar; Ederra, María; Santamariña, Carmen; Moreno, María Pilar; Casanova, Francisco; Pedraz-Pingarrón, Carmen; Moreo, Pilar; Ascunce, Nieves; García, Montse; Salas-Trejo, Dolores; Sánchez-Contador, Carmen; Llobet, Rafael; Lope, Virginia

    2017-11-01

    High mammographic density is one of the main risk factors for breast cancer. Although several occupations have been associated with breast cancer, there are no previous occupational studies exploring the association with mammographic density. Our objective was to identify occupations associated with high mammographic density in Spanish female workers. We conducted a population-based cross-sectional study of occupational determinants of high mammographic density in Spain, based on 1476 women, aged 45-68 years, recruited from seven screening centers within the Spanish Breast Cancer Screening Program network. Reproductive, family, personal, and occupational history data were collected. The latest occupation of each woman was collected and coded according to the 1994 National Classification of Occupations. Mammographic density was assessed from the cranio-caudal mammogram of the left breast using a semi-automated computer-assisted tool. Association between mammographic density and occupation was evaluated by using mixed linear regression models, using log-transformed percentage of mammographic density as dependent variable. Models were adjusted for age, body mass index, menopausal status, parity, smoking, alcohol intake, educational level, type of mammography, first-degree relative with breast cancer, and hormonal replacement therapy use. Screening center and professional reader were included as random effects terms. Mammographic density was higher, although non-statistically significant, among secondary school teachers (e β = 1.41; 95%CI = 0.98-2.03) and nurses (e β = 1.23; 95%CI = 0.96-1.59), whereas workers engaged in the care of people (e β = 0.81; 95%CI = 0.66-1.00) and housewives (e β = 0.87; 95%CI = 0.79-0.95) showed an inverse association with mammographic density. A positive trend for every 5 years working as secondary school teachers was also detected (p-value = 0.035). Nurses and secondary school teachers were the occupations with the highest

  16. High mammographic density is associated with an increase in stromal collagen and immune cells within the mammary epithelium.

    Science.gov (United States)

    Huo, Cecilia W; Chew, Grace; Hill, Prue; Huang, Dexing; Ingman, Wendy; Hodson, Leigh; Brown, Kristy A; Magenau, Astrid; Allam, Amr H; McGhee, Ewan; Timpson, Paul; Henderson, Michael A; Thompson, Erik W; Britt, Kara

    2015-06-04

    Mammographic density (MD), after adjustment for a women's age and body mass index, is a strong and independent risk factor for breast cancer (BC). Although the BC risk attributable to increased MD is significant in healthy women, the biological basis of high mammographic density (HMD) causation and how it raises BC risk remain elusive. We assessed the histological and immunohistochemical differences between matched HMD and low mammographic density (LMD) breast tissues from healthy women to define which cell features may mediate the increased MD and MD-associated BC risk. Tissues were obtained between 2008 and 2013 from 41 women undergoing prophylactic mastectomy because of their high BC risk profile. Tissue slices resected from the mastectomy specimens were X-rayed, then HMD and LMD regions were dissected based on radiological appearance. The histological composition, aromatase immunoreactivity, hormone receptor status and proliferation status were assessed, as were collagen amount and orientation, epithelial subsets and immune cell status. HMD tissue had a significantly greater proportion of stroma, collagen and epithelium, as well as less fat, than LMD tissue did. Second harmonic generation imaging demonstrated more organised stromal collagen in HMD tissues than in LMD tissues. There was significantly more aromatase immunoreactivity in both the stromal and glandular regions of HMD tissues than in those regions of LMD tissues, although no significant differences in levels of oestrogen receptor, progesterone receptor or Ki-67 expression were detected. The number of macrophages within the epithelium or stroma did not change; however, HMD stroma exhibited less CD206(+) alternatively activated macrophages. Epithelial cell maturation was not altered in HMD samples, and no evidence of epithelial-mesenchymal transition was seen; however, there was a significant increase in vimentin(+)/CD45(+) immune cells within the epithelial layer in HMD tissues. We confirmed increased

  17. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  18. The mammographic correlations of a new immunohistochemical classification of invasive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taneja, S. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom)], E-mail: sheeba_taneja@yahoo.co.uk; Evans, A.J. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Rakha, E.A.; Green, A.R. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom); Ball, G. [Nottingham Trent University, School of Biomedical and Natural Sciences, Nottingham (United Kingdom); Ellis, I.O. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom)

    2008-11-15

    Aim: Recent protein expression profiling of breast cancer has identified specific subtypes with clinical, biological, and therapeutic implications. The aim of this study was to identify the mammographic correlates of these novel molecular classes of invasive breast cancer. Materials and methods: The mammographic findings of 415 patients with operable breast cancer were correlated with the previously described protein expression classes identified by our group using immunohistochemical (IHC) assessment of a large series of breast cancer cases prepared as tissue microarrays (TMAs). Twenty-five proteins of known relevance in breast cancer were assessed, including hormone receptors, HER-2 status, basal and luminal markers, p53 expression, and E-cadherin. Results: The mammographic background pattern and proportion of lesions that were mammographically occult were similar in all groups. Groups characterized by luminal and hormone receptor positivity had significantly more spiculate lesions at mammography. Groups characterized by HER-2 overexpression, basal characteristics, and E-cadherin positivity had a significantly higher proportion of ill-defined masses. These findings were independent of histological grade. Conclusion: The mammographic features of breast cancer show significant correlation with molecular classes of invasive breast cancer identified by protein expression IHC analysis. The biological reasons for the findings and implications of these regarding imaging protocols require further study and may provide mechanisms for improvement of detection of these lesions.

  19. Applying a new mammographic imaging marker to predict breast cancer risk

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin

    2018-02-01

    Identifying and developing new mammographic imaging markers to assist prediction of breast cancer risk has been attracting extensive research interest recently. Although mammographic density is considered an important breast cancer risk, its discriminatory power is lower for predicting short-term breast cancer risk, which is a prerequisite to establish a more effective personalized breast cancer screening paradigm. In this study, we presented a new interactive computer-aided detection (CAD) scheme to generate a new quantitative mammographic imaging marker based on the bilateral mammographic tissue density asymmetry to predict risk of cancer detection in the next subsequent mammography screening. An image database involving 1,397 women was retrospectively assembled and tested. Each woman had two digital mammography screenings namely, the "current" and "prior" screenings with a time interval from 365 to 600 days. All "prior" images were originally interpreted negative. In "current" screenings, these cases were divided into 3 groups, which include 402 positive, 643 negative, and 352 biopsy-proved benign cases, respectively. There is no significant difference of BIRADS based mammographic density ratings between 3 case groups (p cancer detection in the "current" screening. Study demonstrated that this new imaging marker had potential to yield significantly higher discriminatory power to predict short-term breast cancer risk.

  20. Mammographic breast density patterns in asymptomatic mexican women.

    Science.gov (United States)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ(2)) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns.

  1. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  2. Effects of repeated mammographic screening on breast cancer stage distribution

    International Nuclear Information System (INIS)

    Fagerberg, G.; Baldetorp, L.; Groentoft, O.; Lundstroem, B.; Maanson, J.C.; Nordenskjoeld, B.

    1985-01-01

    A randomised controlled trial of mass screening for breast cancer by single-view mammography was begun in Sweden in 1977. All women aged 40 and older and resident in the counties of Koppaberg and Oestergoetland were enrolled. The present report is confined to the Oestergoetland study, which started in 1978 and comprised 92934 women. After randomisation, which was done on the basis of communities rather than individuals, 47001 women were allocated to the study group and offered repeated mammographic screening; 45933 were allocated to the control group. As compliance among women over 74 years of age was poor these were excluded from the present report. The yearly incidence of stage II or more advanced breast cancers after the initial screening round up to and including the second was reduced by 40 per cent in the study group compared with the controls. This effect was less marked in the age group 40-49. After 5.5 years average from the date of entry the absolute number of women with stage II-IV disease in the control group exceeded that for the study group by 44, whereas there was a large excess of cancer in situ and stage I cancer in the study group. (orig.)

  3. Classification of mammographic masses using generalized dynamic fuzzy neural networks

    International Nuclear Information System (INIS)

    Lim, Wei Keat; Er, Meng Joo

    2004-01-01

    In this article, computer-aided classification of mammographic masses using generalized dynamic fuzzy neural networks (GDFNN) is presented. The texture parameters, derived from first-order gradient distribution and gray-level co-occurrence matrices, were computed from the regions of interest. A total of 343 images containing 180 benign masses and 163 malignant masses from the Digital Database for Screening Mammography were analyzed. A fast approach of automatically generating fuzzy rules from training samples was implemented to classify tumors. This work is novel in that it alleviates the problem of requiring a designer to examine all the input-output relationships of a training database in order to obtain the most appropriate structure for the classifier in a conventional computer-aided diagnosis. In this approach, not only the connection weights can be adjusted, but also the structure can be self-adaptive during the learning process. By virtue of the automatic generation of the classifier by the GDFNN learning algorithm, the area under the receiver-operating characteristic curve, A z , attains 0.868±0.020, which corresponds to a true-positive fraction of 95.0% at a false positive fraction of 52.8%. The corresponding accuracy is 70.0%, the positive predictive value is 62.0%, and the negative predictive value is 91.4%

  4. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  5. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Garciduenas, A.L.C.; Amador, N.; Mondragon, M.S.; Hernaan, L.; Cerda-Flores, R.M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (X 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  6. A study of mammographic and thermographic findings in breast diseases

    International Nuclear Information System (INIS)

    Cho, Won Sik; Jeon, Woo Ki; Kim, Jeong Sook; Han, Chang Yul

    1989-01-01

    The ideal diagnostic methods in breast diseases consist of the physical examination and complementary radiologic examination. In radiologic examination mammography is the most popular screening methods and the older simple complementary method is thermography which is efficient under the conditions of elevated skin temperature in inflammatory and malignant lesions. From Jan. 1st 1987 through Jan. 30th, 1988, 110 pts. with complaints of mammary problems were examined by mammography and thermography at Paik Hospital, Inje University. The authors selected and analyzed 97 cases had been pathologically proved through the operation and the fine needle aspiration biopsy. The results were as follows: 1. The most prevalent age group was 5th decade (40%) in cancer, 4th decade (47%) in mammary dysplasia and followed by fibroadenoma (63%) in 4th decade. 2. The mammographic and thermographic findings were compared between the mammary dysplasia and the infiltrating ductal cancer. In mammary dysplasia abnormal hot emissions were appeared in 9/44 (17%) correlated with atypical hyperchromatic cytoplasm relates to pre-malignant group. 3. We hope and expect the early detection of breast cancer through the follow-up study in pre-malignant group of mammary dysplasia

  7. Mammographically detected breast arterial calcifications: Indicators for arteriosclerotic diseases?

    International Nuclear Information System (INIS)

    Taskin, Fuesun; Akdilli, Alev; Karaman, Can; Unsal, Alparslan; Koeseoglu, Kutsi; Ergin, Filiz

    2006-01-01

    Purpose: To determine the prevalence of breast arterial calcifications (BAC) detected on mammography and search for conditions that may influence their existence. Materials and methods: The mammograms of 6156 consecutive patients were reevaluated for the presence of BAC. Four hundred eighty-five women having BAC were enrolled in the patient group. Additionally, randomly selected 500 women, without BAC constituted the control group. Hospital records of the participants were reviewed for parity, menopausal status, oral contraceptive agent (OCA) usage, hormone replacement therapy (HRT) usage, presence of diabetes, hypertension, hyperlipidemia, albuminuria and history of myocardial infarction (MI). Results: Prevalence of BAC was 7.9% on mammograms. Ninety-four women were aged between 40 and 49 years, 165 were aged between 50 and 59 years and 226 were over 60 years among BAC positive 485 women. A significant relationship was found for the frequency of BAC versus age and HRT usage in all age groups (p 0.05). Conclusion: Most benign findings like BAC are not routinely reported during mammographic evaluation. Our study showed that, presence of BAC on mammography was strongly related to advancing age. However, these findings may signify a systemic risk and can be used as precautious indicators for undocumented systemic diseases, especially in premenopausal women

  8. Breast Tissue Composition and Immunophenotype and Its Relationship with Mammographic Density in Women at High Risk of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Jia-Min B Pang

    Full Text Available To investigate the cellular and immunophenotypic basis of mammographic density in women at high risk of breast cancer.Mammograms and targeted breast biopsies were accrued from 24 women at high risk of breast cancer. Mammographic density was classified into Wolfe categories and ranked by increasing density. The histological composition and immunophenotypic profile were quantified from digitized haematoxylin and eosin-stained and immunohistochemically-stained (ERα, ERβ, PgR, HER2, Ki-67, and CD31 slides and correlated to mammographic density.Increasing mammographic density was significantly correlated with increased fibrous stroma proportion (rs (22 = 0.5226, p = 0.0088 and significantly inversely associated with adipose tissue proportion (rs (22 = -0.5409, p = 0.0064. Contrary to previous reports, stromal expression of ERα was common (19/20 cases, 95%. There was significantly higher stromal PgR expression in mammographically-dense breasts (p=0.026.The proportion of stroma and fat underlies mammographic density in women at high risk of breast cancer. Increased expression of PgR in the stroma of mammographically dense breasts and frequent and unexpected presence of stromal ERα expression raises the possibility that hormone receptor expression in breast stroma may have a role in mediating the effects of exogenous hormonal therapy on mammographic density.

  9. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye [Jeil Women' s Hospital, Seoul (Korea, Republic of)

    1997-06-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously.

  10. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    International Nuclear Information System (INIS)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye

    1997-01-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously

  11. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  12. Mammographic findings predicting an extensive intraductal component in early stage invasive breast cancer : analysis on microcalcification

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Kim, Mi Hye; Lee, Mi Kyung; Oh, Ki Keun; Kim, Eun Kyung

    2000-01-01

    To analyze the mammographic findings of extensive intraductal component (EIC)-positive early invasive breast carcinoma and to determine the mammographic features which predict an EIC positivity in an invasive carcinoma. The mammographic and pathologic findings in 71 patients aged 34-79 (mean 50) years in whom stage I or II invasive breast carcinoma had been diagnosed were retrospectively analysed. The mammographic findings were assigned to one of three groups: mass, mass with microcalcification, or microcalcification only. The shape and distribution of a calcification were classified according to the BI-RADS lexicon, and its extent was classified as either more or less than 3 cm. To detect the presence or absence of EIC and the type of ductal carcinoma in situ (DCIS), the findings were re-examined by means of slide mappings. Twenty-eight of 71 patients (39%) showed ECI positivity. The mammographic findings of EIC-positive invasive cancer (n=3D28) were mass with microcalcification (n=3D14), microcalcification only (n=3D7) and mass only (n=3D7). The mammographic finding which predicted EIC positivity was mass with microcalcification (PPV:0.67, NPV:0.33, p=3D0.02). A mammographic of mass only (n=3D39) showed a significantly high negative predictive value for EIC positivity. (PPV 0.18, NPV 0.82, P less than 0.01). A comparison of cases with or without calcification showed that those with microcalcifications (n=3D32) showed a significantly high PPV of 0.66 (NPV:0.34, p less than 0.01) while those without calcification (n=3D39) showed a significantly high NPV of 0.82 (PPV:0.18, p less than 0.01). There were no significant differences in positive predictive values for EIC between the shape, distribution and extent of calcifications. Whenever microcalcification with or without mass is seen on mammographs obtained during early breast cancer, we can predict EIC-positivity, regardless of shape or distribution according to the BI-RADS lexicon. (author)

  13. American College of Radiology Accreditation Program for mammographic screening sites: Physical evaluation criteria

    International Nuclear Information System (INIS)

    Hendrick, R.E.; Haus, A.G.; Hubbard, L.B.; Lasky, H.J.; McCrohan, J.; McLelland, R.; Rothenberg, L.N.; Tanner, R.L.; Zinninger, M.D.

    1987-01-01

    The American College of Radiology has initiated a program for the accreditation of mammographic screening sites, which includes evaluation by mail of image quality and average glandular breast dose. Image quality is evaluated by use of a specially designed phantom (a modified RMI 152D Mammographic Phantom) containing simulated microcalcifications, fibrils and masses. Average glandular dose to a simulated 4.5-cm-thick (50% glandular, 50% fat) compressed breast is evaluated by thermoluminescent dosimeter measurements of entrance exposure and half value layer. Standards for acceptable image quality and patient doses are presented and preliminary results of the accreditation program are discussed

  14. Mammographic and sonographic findings of breast cancer in women younger than 35 years

    International Nuclear Information System (INIS)

    Shaw de Paredes, E.; Marsteller, L.; Eden, B.

    1989-01-01

    Breast carcinoma is uncommon in women under 35 years of age and may be difficult to detect because clinically palpable masses are usually benign, and mammography may be limited by dense parenchyma. The purpose of this work was to evaluate the mammographic findings in young patients with breast cancer and the efficacy of mammography in identifying these lesions. During an 8-year period, 100 breast cancers were diagnosed mammography and sonography were performed in 678% and 19% of patients, respectively; mammography demonstrated the lesion in 90% of cases. Mammographic and sonographic findings are presented

  15. Automated mammographic breast density estimation using a fully convolutional network.

    Science.gov (United States)

    Lee, Juhun; Nishikawa, Robert M

    2018-03-01

    The purpose of this study was to develop a fully automated algorithm for mammographic breast density estimation using deep learning. Our algorithm used a fully convolutional network, which is a deep learning framework for image segmentation, to segment both the breast and the dense fibroglandular areas on mammographic images. Using the segmented breast and dense areas, our algorithm computed the breast percent density (PD), which is the faction of dense area in a breast. Our dataset included full-field digital screening mammograms of 604 women, which included 1208 mediolateral oblique (MLO) and 1208 craniocaudal (CC) views. We allocated 455, 58, and 91 of 604 women and their exams into training, testing, and validation datasets, respectively. We established ground truth for the breast and the dense fibroglandular areas via manual segmentation and segmentation using a simple thresholding based on BI-RADS density assessments by radiologists, respectively. Using the mammograms and ground truth, we fine-tuned a pretrained deep learning network to train the network to segment both the breast and the fibroglandular areas. Using the validation dataset, we evaluated the performance of the proposed algorithm against radiologists' BI-RADS density assessments. Specifically, we conducted a correlation analysis between a BI-RADS density assessment of a given breast and its corresponding PD estimate by the proposed algorithm. In addition, we evaluated our algorithm in terms of its ability to classify the BI-RADS density using PD estimates, and its ability to provide consistent PD estimates for the left and the right breast and the MLO and CC views of the same women. To show the effectiveness of our algorithm, we compared the performance of our algorithm against a state of the art algorithm, laboratory for individualized breast radiodensity assessment (LIBRA). The PD estimated by our algorithm correlated well with BI-RADS density ratings by radiologists. Pearson's rho values of

  16. Generation of CR mammographic image for evaluation quality parameters

    International Nuclear Information System (INIS)

    Flores, Mabel B.; Mourao, Arnaldo P.; Centro Federal de Educacao Tecnologica de Minas Gerais

    2017-01-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  17. A study of mammographic appearance of the breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik [College of Medicine, Yeung Nam University, Gyeongsan (Korea, Republic of)

    1985-08-15

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  18. A study of mammographic appearance of the breast disease

    International Nuclear Information System (INIS)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik

    1985-01-01

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  19. Mammographic and Ultrasonographic Findings of the Chemoport Insertion Site

    International Nuclear Information System (INIS)

    Kim, Seun Jung; Kang, Bong Joo; Cha, Eun Suk; Park, Hye Jung; Kim, Sung Hun; Choi, Jae Jeong; Lee, Ji Hye

    2010-01-01

    To describe mammographic and ultrasonographic findings of previous chemoport insertion sites. We included patients who had abnormal findings at chemoport insertion sites on mammography and ultrasonography from 224 patients who underwent chemoport insertion and breast imaging at our institution between January, 2005, and December, 2007. Abnormal findings were identified in 16 mammographies and 14 ultrasonographies in 10 patients. The mean age was 50.9 years and the age range was from 44 to 67 years. Abnormal findings on mammography and ultrasonography were retrospectively analyzed according to ACR/BI-RADS. All cases were followed up with imaging studies for 2 years to confirm changes after chemoport insertion. Of the abnormal findings identified on mammography, focal asymmetry (7/16) was the most common. Other abnormal findings included mass (6/16), skin retraction (2/16), residual chemoport tip (1/16), and trabecular thickening (1/16). Of the abnormal findings seen on ultrasonography, skin thickening (12/14) was the most common. Other abnormal findings included mass (5/14), diffuse increased echogenicity of subcutaneous tissue (1/14), and a localized skin nodule (1/14). Abnormal findings on mammography and ultrasonography were located in the upper outer quadrant in 5 patients, upper inner quadrant in 3 patients, and mid upper portion in 1 patient. In 1 patient, the abnormal finding was only identified in the mediolateral oblique view of her mammography. Radiologists should be aware of potential abnormal findings on mammography and ultrasonography following chemoport insertion. In particular, ultrasonography is a very useful modality for detecting skin complications after chemoport insertion

  20. Relevance analysis of mammographic parenchymal patterns and breast cancer

    International Nuclear Information System (INIS)

    Feng Rendong; Lv Xiangyang; Li Shaolin; Gao Ming; Miao Liqiong

    2009-01-01

    Objective: Discussing the relativity of Mammographic parenchymal patterns and breast cancer, implementing the intervention treatment and regularly traces to the breast high dangerous crowd, in order to reduce the occurrence rate of beast cancer and the mortality rate. Methods: Mammary gland type was marked according to X ray on 500 breast cancer subjects and 1000 control subjects. Peri-cancer histological sections of the subtypes of the breast cancer group and histological section of the subtypes of the control group were studied contrastively to analyze the breast cancer risk index in every subtype and the occurrence rate in every age group. The types and the occurrence rates were counted. Results: (1)The lowest risk group: the subtypes with OR 0.3 and the cancer incidence rate ranging from 5% to 10% were IV b, II b, III b. (4)High-risk group: the subtypes with OR> 1 and the cancer incidence rate above 10% were III c, IV c. High dangerous age sections of breast cancer: 35 to 55 years old in IVc and IIIc (the age section of IIIc may lengthen to 60 years old), 31 to 50 years old in IVb, 50 to 60 years old in IIIb and IIb. Conclusion: IIIc and IVc belong to the high dangerous subtypes. People of these subtypes reach 67.4% of all breast cancer examples, so these people are the main subjects of the mammary gland general survey and tracing. Patient aged from 35 to 55 should be reexamined once a year. When necessary, the intervention treatment may be carried out to prevent breast cancer and to reduce the occurrence rate of beast cancer. Discovery and treatment in early phase can improve the breast cancer's survival quality, and reduce the mortality rate. (authors)

  1. Spectral analysis of mammographic images using a multitaper method

    International Nuclear Information System (INIS)

    Wu Gang; Mainprize, James G.; Yaffe, Martin J.

    2012-01-01

    Purpose: Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum estimation of images, whose content deviates significantly from uniform white noise. The performance of the multitaper approach will be evaluated in terms of spectral stability, variance reduction, bias, and frequency precision. The ultimate goal is the development of a useful tool for image quality assurance. Methods: A multitaper approach uses successive data windows of increasing order. This mitigates spectral leakage allowing one to calculate a reduced-variance power spectrum. The multitaper approach will be compared with the conventional power spectrum method in several typical situations, including the noise power spectra (NPS) measurements of simulated projection images of a uniform phantom, NPS measurement of real detector images of a uniform phantom for two clinical digital mammography systems, and the estimation of the anatomic noise in mammographic images (simulated images and clinical mammograms). Results: Examination of spectrum variance versus frequency resolution and bias indicates that the multitaper approach is superior to the conventional single taper methods in the prevention of spectrum leakage and variance reduction. More than four times finer frequency precision can be achieved with equivalent or less variance and bias. Conclusions: Without any shortening of the image data length, the bias is smaller and the frequency resolution is higher with the multitaper method, and the need to compromise in the choice of regions of interest size to balance between the reduction of variance and the loss of frequency resolution is largely eliminated.

  2. Generation of CR mammographic image for evaluation quality parameters

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Mabel B.; Mourao, Arnaldo P., E-mail: mbustos@ufmg.br, E-mail: apratabhz@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Politecnica

    2017-11-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  3. Breast ultrasonographic and histopathological characteristics without any mammographic abnormalities

    International Nuclear Information System (INIS)

    Tamaki, Kentaro; Kamada, Yoshihiko; Uehara, Kano; Tamaki, Nobumitsu; Ishida, Takanori; Miyashita, Minoru; Amari, Masakazu; Ohuchi, Noriaki; Sasano, Hironobu

    2012-01-01

    We evaluated ultrasonographic findings and the corresponding histopathological characteristics of breast cancer patients with Breast Imaging Reporting and Data System (BI-RADS) category 1 mammogram. We retrospectively reviewed the ultrasonographic findings and the corresponding histopathological features of 45 breast cancer patients with BI-RADS category 1 mammogram and 537 controls with mammographic abnormalities. We evaluated the ultrasonographic findings including mass shape, periphery, internal and posterior echo pattern, interruption of mammary borders and the distribution of low-echoic lesions, and the corresponding histopathological characteristics including histological classification, hormone receptor and human epidermal growth factor receptor 2 status of invasive ductal carcinoma and ductal carcinoma in situ, histological grade, mitotic counts and lymphovascular invasion in individual cases of BI-RADS category 1 mammograms and compared with those of the control group. The ultrasonographic characteristics of the BI-RADS category 1 group were characterized by a higher ratio of round shape (P<0.001), non-spiculated periphery (P=0.021), non-interruption of mammary borders (P<0.001) and non-attenuation (P=0.011) compared with the control group. A total of 52.6% of low-echoic lesions were associated with spotted distribution in the BI-RADS 1 group, whereas 25.8% of low-echoic lesions were associated with spotted distribution in the control group (P=0.012). As for histopathological characteristics, there was a statistically higher ratio of triple-negative subtype (P=0.021), and this particular tendency was detected in histological grade 3 in the BI-RADS category 1 group (P=0.094). We evaluated ultrasonographic findings and the corresponding histopathological characteristics for BI-RADS category 1 mammograms and noted significant differences among these findings in this study. Evaluation of these ultrasonographic and histopathological characteristics may provide

  4. Birth weight, childhood body mass index, and height in relation to mammographic density and breast cancer

    DEFF Research Database (Denmark)

    Andersen, Zorana Jovanovic; Baker, Jennifer Lyn; Bihrmann, Kristine

    2014-01-01

    High breast density, a strong predictor of breast cancer may be determined early in life. Childhood anthropometric factors have been related to breast cancer and breast density, but rarely simultaneously. We examined whether mammographic density (MD) mediates an association of birth weight, child...

  5. International Consortium on Mammographic Density : Methodology and population diversity captured across 22 countries

    NARCIS (Netherlands)

    McCormack, Valerie A; Burton, Anya; Dos-Santos-Silva, Isabel; Hipwell, John H; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Lee, Charmaine Pei Ling; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H; Wanders, Johanna O P; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Won Lee, Jong; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J; Schüz, Joachim; Chiarelli, Anna M; Linton, Linda; Boyd, Norman F

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with

  6. Immediate and delayed effects of mammographic screening on breast cancer mortality and incidence in birth cohorts

    NARCIS (Netherlands)

    Ripping, T. M.; Verbeek, A. L. M.; van der Waal, D.; Otten, J. D. M.; den Heeten, G. J.; Fracheboud, J.; de Koning, H. J.; Broeders, M. J. M.

    2013-01-01

    Trend studies investigating the impact of mammographic screening usually display age-specific mortality and incidence rates over time, resulting in an underestimate of the benefit of screening, that is, mortality reduction, and an overestimate of its major harmful effect, that is, overdiagnosis.

  7. Immediate and delayed effects of mammographic screening on breast cancer mortality and incidence in birth cohorts

    NARCIS (Netherlands)

    Ripping, T.M.; Verbeek, A.L.M.; Waal, D. van der; Otten, J.D.M.; Heeten, G.J. den; Fracheboud, J.; Koning, H.J. de; Broeders, M.J.M.

    2013-01-01

    Background:Trend studies investigating the impact of mammographic screening usually display age-specific mortality and incidence rates over time, resulting in an underestimate of the benefit of screening, that is, mortality reduction, and an overestimate of its major harmful effect, that is,

  8. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    Science.gov (United States)

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Po-Hao, E-mail: howard_chen@post.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Department of Radiology, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadlephia, PA 19104 (United States); Slanetz, Priscilla J., E-mail: pslanetz@bidmc.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Beth Israel Deaconess Medical Center, Department of Radiology, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2014-01-15

    Purpose: To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Materials and Methods: Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. Results: A total of 353 mammograms were obtained from 327 unique patients (ages 18–95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Conclusion: Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management.

  10. Residential traffic noise and mammographic breast density in the Diet, Cancer, and Health cohort

    DEFF Research Database (Denmark)

    Roswall, Nina; Andersen, Zorana Jovanovic; von Euler-Chelpin, My

    2018-01-01

    OBJECTIVES: Traffic is the most important source of community noise, and it has been proposed to be associated with a range of disease outcomes, including breast cancer. As mammographic breast density (MD) is one of the strongest risk factors for developing breast cancer, the present study...

  11. Remote Patient Management in a Mammographic Screening Environment in Underserved Areas

    Science.gov (United States)

    2005-09-01

    of 4,945 paired examinations. Radiology 2001; 218:873-880. 10. Malich A, Marx C, Facius M, Boehm T, Fleck M, Kaiser WA. Tumour 24. Venta LA, Hendrick...218:873-880. KF, Sickles EA. Mammographic character- factor determining the quality of com- 15. Venta LA, Hendrick RE, Adler YT, et al. iSicks of 115

  12. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (pChinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (pChinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  13. A deep learning method for classifying mammographic breast density categories.

    Science.gov (United States)

    Mohamed, Aly A; Berg, Wendie A; Peng, Hong; Luo, Yahong; Jankowitz, Rachel C; Wu, Shandong

    2018-01-01

    Mammographic breast density is an established risk marker for breast cancer and is visually assessed by radiologists in routine mammogram image reading, using four qualitative Breast Imaging and Reporting Data System (BI-RADS) breast density categories. It is particularly difficult for radiologists to consistently distinguish the two most common and most variably assigned BI-RADS categories, i.e., "scattered density" and "heterogeneously dense". The aim of this work was to investigate a deep learning-based breast density classifier to consistently distinguish these two categories, aiming at providing a potential computerized tool to assist radiologists in assigning a BI-RADS category in current clinical workflow. In this study, we constructed a convolutional neural network (CNN)-based model coupled with a large (i.e., 22,000 images) digital mammogram imaging dataset to evaluate the classification performance between the two aforementioned breast density categories. All images were collected from a cohort of 1,427 women who underwent standard digital mammography screening from 2005 to 2016 at our institution. The truths of the density categories were based on standard clinical assessment made by board-certified breast imaging radiologists. Effects of direct training from scratch solely using digital mammogram images and transfer learning of a pretrained model on a large nonmedical imaging dataset were evaluated for the specific task of breast density classification. In order to measure the classification performance, the CNN classifier was also tested on a refined version of the mammogram image dataset by removing some potentially inaccurately labeled images. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to measure the accuracy of the classifier. The AUC was 0.9421 when the CNN-model was trained from scratch on our own mammogram images, and the accuracy increased gradually along with an increased size of training samples

  14. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    International Nuclear Information System (INIS)

    Zheng, Bin; Sumkin, Jules H.; Zuley, Margarita L.; Wang, Xingwei; Klym, Amy H.; Gur, David

    2012-01-01

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 ± 0.030, 0.535 ± 0.036, 0.567 ± 0.031, and 0.719 ± 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 ± 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  15. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    Energy Technology Data Exchange (ETDEWEB)

    Sala, E.; Solomon, L.; McCann, J. [Department of Community Medicine, Strangeways Research Laboratory, Worts Causeway, Cambridge (United Kingdom); Warren, R. [Cambridge and Huntingdon Breast Screening Service, Rosie Maternity Hospital, Robinson Way, Cambridge (United Kingdom); Duffy, S. [MRC-Biostatistics Unit, Institute of Public Health, Cambridge (United Kingdom); Luben, R. [Department of Clinical Gerontology, Strangeways Research Laboratory, Cambridge (United Kingdom); Day, N. [Department of Community Medicine, Institute of Public Health, Robinson Way, Cambridge, CB2 2SR (United Kingdom)

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  16. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Bin, E-mail: zhengb@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Sumkin, Jules H., E-mail: jsumkin@mail.magee.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Zuley, Margarita L., E-mail: zuleyml@upmc.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Wang, Xingwei, E-mail: wangx6@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Klym, Amy H., E-mail: klymah@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Gur, David, E-mail: gurd@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States)

    2012-11-15

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 {+-} 0.030, 0.535 {+-} 0.036, 0.567 {+-} 0.031, and 0.719 {+-} 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 {+-} 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  17. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    International Nuclear Information System (INIS)

    Sala, E.; Solomon, L.; McCann, J.; Warren, R.; Duffy, S.; Luben, R.; Day, N.

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  18. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  19. Feature extraction using convolutional neural network for classifying breast density in mammographic images

    Science.gov (United States)

    Thomaz, Ricardo L.; Carneiro, Pedro C.; Patrocinio, Ana C.

    2017-03-01

    Breast cancer is the leading cause of death for women in most countries. The high levels of mortality relate mostly to late diagnosis and to the direct proportionally relationship between breast density and breast cancer development. Therefore, the correct assessment of breast density is important to provide better screening for higher risk patients. However, in modern digital mammography the discrimination among breast densities is highly complex due to increased contrast and visual information for all densities. Thus, a computational system for classifying breast density might be a useful tool for aiding medical staff. Several machine-learning algorithms are already capable of classifying small number of classes with good accuracy. However, machinelearning algorithms main constraint relates to the set of features extracted and used for classification. Although well-known feature extraction techniques might provide a good set of features, it is a complex task to select an initial set during design of a classifier. Thus, we propose feature extraction using a Convolutional Neural Network (CNN) for classifying breast density by a usual machine-learning classifier. We used 307 mammographic images downsampled to 260x200 pixels to train a CNN and extract features from a deep layer. After training, the activation of 8 neurons from a deep fully connected layer are extracted and used as features. Then, these features are feedforward to a single hidden layer neural network that is cross-validated using 10-folds to classify among four classes of breast density. The global accuracy of this method is 98.4%, presenting only 1.6% of misclassification. However, the small set of samples and memory constraints required the reuse of data in both CNN and MLP-NN, therefore overfitting might have influenced the results even though we cross-validated the network. Thus, although we presented a promising method for extracting features and classifying breast density, a greater database is

  20. AhR Activation Underlies the CYP1A Autoinduction by A-998679 in Rats

    Directory of Open Access Journals (Sweden)

    Michael J. Liguori

    2012-10-01

    Full Text Available Xenobiotic-mediated induction of cytochrome P450 (CYP drug metabolizing enzymes (DMEs is frequently encountered in drug discovery and can influence disposition, pharmacokinetic, and toxicity profiles. The CYP1A subfamily of DMEs plays a central role in the biotransformation of several drugs and environmental chemicals. Autoinduction of drugs through CYP3A enzymes is a common mechanism for their enhanced clearance. However, autoinduction via CYP1A is encountered less frequently. In this report, an experimental compound, A-998679 (3-(5-pyridin-3-yl-1,2,4-oxadiazol-3-yl benzonitrile, was shown to enhance its own clearance via induction of CYP1A1 and CYP1A2. Rats were dosed for 5 days with 30, 100, and 200 mg/kg/day A-998679. During the dosing period, the compound’s plasma AUC decreased at 30 mg/kg (95% and 100 mg/kg (80%. Gene expression analysis and immunohistochemistry of the livers showed a large increase in the mRNA and protein levels of CYP1A, which was involved in the biotransformation of A-998679. Induction of CYP1A was confirmed in primary rat, human, and dog hepatocytes. The compound also weakly inhibited CYP1A2 in human liver microsomes. A-998679 activated the aryl hydrocarbon receptor (AhR in a luciferase gene reporter assay in HepG2 cells, upregulated expression of genes associated with AhR activation in rat liver, and enhanced nuclear migration of AhR in HepG2 cells. Collectively these results demonstrate that A-998679 is an AhR activator that induces CYP1A1 and CYP1A2 expression, resulting in an autoinduction phenomenon. The unique properties of A-998679, along with its novel structure distinct from classical polycyclic aromatic hydrocarbons, may warrant its further evaluation as a tool compound for use in studies involving AhR biology and CYP1A related mechanisms of drug metabolism and toxicity.

  1. The effects of gender, age, ethnicity, and liver cirrhosis on cytochrome P450 enzyme activity in human liver microsomes and inducibility in cultured human hepatocytes

    International Nuclear Information System (INIS)

    Parkinson, Andrew; Mudra, Daniel R.; Johnson, Cory; Dwyer, Anne; Carroll, Kathleen M.

    2004-01-01

    We have measured cytochrome P450 (CYP) activity in nearly 150 samples of human liver microsomes and 64 samples of cryopreserved human hepatocytes, and we have performed induction studies in over 90 preparations of cultured human hepatocytes. We have analyzed these data to examine whether the expression of CYP enzyme activity in liver microsomes and isolated hepatocytes or the inducibility of CYP enzymes in cultured hepatocytes is influenced by the gender, age, or ethnicity of the donor (the latter being limited to Caucasians, African Americans, and Hispanics due to a paucity of livers from Asian donors). In human liver microsomes, there were no statistically significant differences (P > 0.05) in CYP activity as a function of age, gender, or ethnicity with one exception. 7-Ethoxyresorufin O-dealkylase (CYP1A2) activity was greater in males than females, which is consistent with clinical observation. Liver microsomal testosterone 6β-hydroxylase (CYP3A4) activity was slightly greater in females than males, but the difference was not significant. However, in cryopreserved human hepatocytes, the gender difference in CYP3A4 activity (females = twice males) did reach statistical significance, which supports the clinical observation that females metabolize certain CYP3A4 substrates faster than do males. Compared with those from Caucasians and African Americans, liver microsomes from Hispanics had about twice the average activity of CYP2A6, CYP2B6, and CYP2C8 and half the activity of CYP1A2, although this apparent ethnic difference may be a consequence of the relatively low number of Hispanic donors. Primary cultures of hepatocytes were treated with β-naphthoflavone, an inducer of CYP1A2, phenobarbital or rifampin, both of which induce CYP2B6, CYP2C9, CYP2C19, and CYP3A4, albeit it to different extents. Induction of these CYP enzymes in freshly cultured hepatocytes did not appear to be influenced by the gender or age of the donor. Furthermore, CYP3A4 induction in

  2. Comparative analysis among X-ray mammographic findings, nuclear and histologic grading, and TNM staging of breast carcinoma

    International Nuclear Information System (INIS)

    Park, Jin Sook; Sung, Ki Joon; Cho, Mee Yon; Hong, In Soo; Kim, Myung Soon; Oh, Ki Keun

    1996-01-01

    The purpose of this study was to evaluate the prognosis of breast carcinoma by comparison with X-ray mammographic findings, nuclear and histologic grade, and TNM staging. We retrospectively reviewed 114 cases (113 patients) of breast carcinoma, analysing X-ray mammographic findings of all cases with regard to mass, calcification, and spiculation. In 80 cases of scirrhous invasive ductal breast carcinoma. Black's nuclear and Bloom-Richardson's histologic grade were also evaluated. Mammographic findings and nuclear and histologic grade were compared with TNM staging which might suggest the prognosis of breast carcinoma. X-ray mammographic findings (mass, calcification and spiculation) did not significantly correlate with T staging, but the clinical staging of the spiculation was advanced. These X-ray findings did not significantly correlate with the nuclear grading and the histologic grading. Nuclear grade did not correlate with T and M staging, but correlated significantly with N staging and clinical stage(p < 0.05). Histologic grade did not significantly correlate with TNM staging. The clinical staging of spiculation was advanced and nuclear grade correlated significantly with N stage and clinical staging. X-ray mammographic findings did not directly correlate with nuclear and histologic grading, but combined studies of the evaluation of mammographic findings and nuclear and histologic grade were useful for prognosing breast carcinoma

  3. Andrographolide Ameliorates Beta-Naphthoflavone-Induced CYP1A Enzyme Activity and Lipid Peroxidation in Hamsters with Acute Opisthorchiasis.

    Science.gov (United States)

    Udomsuk, Latiporn; Chatuphonprasert, Waranya; Jarukamjorn, Kanokwan; Sithithaworn, Paiboon

    2016-01-01

    Opisthorchis viverrini (OV) infection generates oxidative stress/free radicals and is considered as a primary cause ofcholangiocarcinoma since it primarily triggers sclerosing cholangitis. In this study, the impacts of andrographolide on acute opisthorchaisis in β-naphthoflavone (BNF)-exposed hamsters were investigated. Ethoxyresorufin O-deethylase (EROD) and methoxyresorufin O-demethylase (MROD) activities and Thiobarbituric acid reaction substances (TBARS) assay of andrographolide in acute opisthorchiasis in the BNF-exposed hamsters were assessed. The results showed that andrographolide ameliorated the hepatic CYP1A1 and CYP1A2 activities by decreases of the specific enzymatic reactions of EROD and MROD, respectively, in the BNF-exposed hamsters. Moreover, andrographolide lowered the formation of malondialdehyde in the livers and brains of the hamsters. These observations revealed the promising chemo-protective and antioxidant activities of andrographolide via suppression of the specific EROD and MROD reactions and lipid peroxidation against acute opisthorchiasis in the BNF-exposed hamsters.

  4. Unsupervised deep learning applied to breast density segmentation and mammographic risk scoring

    DEFF Research Database (Denmark)

    Kallenberg, Michiel Gijsbertus J.; Petersen, Peter Kersten; Nielsen, Mads

    2016-01-01

    Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used...... as the input to a simple classifier, two different tasks can be addressed: i) breast density segmentation, and ii) scoring of mammographic texture. The proposed model learns features at multiple scales. To control the models capacity a novel sparsity regularizer is introduced that incorporates both lifetime...... and population sparsity. We evaluated our method on three different clinical datasets. Our state-of-the-art results show that the learned breast density scores have a very strong positive relationship with manual ones, and that the learned texture scores are predictive of breast cancer. The model is easy...

  5. Positive predictive value of abnormal mammographic findings and role of assessment procedures

    International Nuclear Information System (INIS)

    Menna, S.; Marra, V.; Di Virgilio, M.R.; Macchia, G.; Frigerio, A.

    1999-01-01

    To investigate the positive predictive value for cancer of abnormal mammographic findings and the role of assessment, the authors reviewed a series of 962 patients recalled and examined in the first breast screening center of Turin (Italy), out of 18996 women aged 50-59 from 1991 to 1995, within a population-based mammography program. The results of this study confirm the accuracy of mammography in the early detection of breast cancer and the different role of assessment procedures in the various abnormal mammographic findings. The improvement in positive predictive value for screening demonstrates the importance of the learning curve within the screening team. Most of this improvement could be referred to refined diagnostic criteria for calcifications [it

  6. Breast calcifications. A standardized mammographic reporting and data system to improve positive predictive value

    International Nuclear Information System (INIS)

    Perugini, G.; Bonzanini, B.; Valentino, C.

    1999-01-01

    The purpose of this work is to investigate the usefulness of a standardized reporting and data system in improving the positive predictive value of mammography in breast calcifications. Using the Breast Imaging Reporting and Data System lexicon developed by the American College of Radiology, it is defined 5 descriptive categories of breast calcifications and classified diagnostic suspicion of malignancy on a 3-grade scale (low, intermediate and high). Two radiologists reviewed 117 mammographic studies selected from those of the patients submitted to surgical biopsy for mammographically detected calcifications from January 1993 to December 1997, and classified them according to the above criteria. The positive predictive value was calculated for all examinations and for the stratified groups. Defining a standardized system for assessing and describing breast calcifications helps improve the diagnostic accuracy of mammography in clinical practice [it

  7. Mammographic Texture Resemblance generalizes as an independent risk factor of breast cancer

    DEFF Research Database (Denmark)

    Chernoff, Konstantin; Christopher, S G; Karemore, Gopal

    PURPOSE Breast density has been established as a risk factor of breast cancer in numerous studies. Mammographic Texture Resemblance (MTR) has shown to be a density independent risk factor, but only on a single study. We examine if the statistics of the texture recorded in one study generalize...... as an independent risk factor in an unrelated cohort. METHOD AND MATERIALS The statistics of texture were recorded in digitalized film-mammograms of one 4-year prospective study (S1, Dutch screening program) of 245 breast cancers and 250 matched controls. From an independent cohort study (S2, Mayo Mammography...... Health Study cohort) 226 incident breast cancer cases diagnosed through 2008 and 442 matched controls (on age) were used for scoring screening digitized mammograms that were ascertained years prior to diagnosis 1993-2006. Mammographic percent density (PD), using Cumulus, and other major risk factors were...

  8. A novel and automatic mammographic texture resemblance marker is an independent risk factor for breast cancer

    DEFF Research Database (Denmark)

    Nielsen, Mads; Karemore, Gopal; Loog, Marco

    2011-01-01

    Objective: We investigated whether breast cancer is predicted by a breast cancer risk mammographic texture resemblance (MTR) marker. Methods: A previously published case-control study included 495 women of which 245 were diagnosed with breast cancer. In baseline mammograms, 2-4 years prior...... to diagnosis, the following mammographic parameters were analysed for relation to breast cancer risk: (C) categorical parenchymal pattern scores; (R) radiologist's percentage density, (P) computer-based percentage density; (H) computer-based breast cancer risk MTR marker; (E) computer-based hormone replacement...... treatment MTR marker; and (A) an aggregate of P and H. Results: Density scores, C, R, and P correlated (tau=0.3-0.6); no other pair of scores showed large (tau>0.2) correlation. For the parameters, the odds ratios of future incidence of breast cancer comparing highest to lowest categories (146 and 106...

  9. Regional trends in breast cancer incidence and mortality in Denmark prior to mammographic screening

    DEFF Research Database (Denmark)

    Andreasen, A H; Andersen, K W; Madsen, Mette

    1994-01-01

    To provide a basis for the evaluation of mammographic screening programmes in Denmark, a study was undertaken of the regional differences in breast cancer incidence and mortality. All 16 regions were followed for the 20 year period, 1970-89, before the start of the first population...... among women below age 60. The mortality was more stable, changing only from 24 to 28 (per 100,000 standardised WSP), but a significant increase occurred in the late 1980s. The study showed regional differences in both incidence and mortality of breast cancer in Denmark. Both the incidence......-based mammographic screening programme in the Copenhagen municipality in 1991. Multiplicative Poisson models were used for the analysis. In general, the incidence increased during this period from 55 to 70 [per 100,000 standardised world standard population (WSP)], and the analysis shows this to be most pronounced...

  10. Evaluation of the optimum region for mammographic system using computer simulation to study modulation transfer functions

    International Nuclear Information System (INIS)

    Oliveira, Isaura N. Sombra; Schiable, Homero; Porcel, Naider T.; Frere, Annie F.; Marques, Paulo M.A.

    1996-01-01

    An investigation of the 'optimum region' of the radiation field considering mammographic systems is studied. Such a region was defined in previous works as the field range where the system has its best performance and sharpest images. This study is based on a correlation of two methods for evaluating radiologic imaging systems, both using computer simulation in order to determine modulation transfer functions (MTFs) due to the X-ray tube focal spot in several field orientation and locations

  11. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  12. Vacuum-assisted breast biopsy of suspected mammographic breast diagnoses: predictive value of serum proteomic profile

    International Nuclear Information System (INIS)

    Schittulli, F.; Ventrella, V.

    2009-01-01

    The project planned a series of actions oriented to different scientific questions: to complete the prospective collection of serum samples for serum proteomic analysis according to SOPs needed for the Italy-USA program; the identification of different mammographic signs for prediction of histological diagnosis of breast lesions through mammotone; the analysis of relationship between serum proteomic profile and micro histology characteristics of breast lesions

  13. Fertility drug use and mammographic breast density in a mammography screening cohort of premenopausal women

    OpenAIRE

    Sprague, Brian L.; Trentham-Dietz, Amy; Terry, Mary Beth; Nichols, Hazel B.; Bersch, Andy J.; Buist, Diana S. M.

    2008-01-01

    The widespread use of ovulation-inducing drugs to enhance fertility has raised concerns regarding potential effects on breast cancer risk, as ovarian stimulation is associated with increases in estrogen and progesterone levels. We investigated the short-term relation between fertility drug use and mammographic breast density, a strong marker of breast cancer risk, among participants in the Group Health Breast Cancer Screening Program. Data linkage with Group Health’s automated pharmacy record...

  14. US and mammographic findings of myofibroblastoma in the female breast: a case report

    International Nuclear Information System (INIS)

    Ko, Seog Wan; Jeon, Soo Bin; Lee, Ji Shin; Kim, Dong Sug

    2005-01-01

    Myofibroblastoma is a rare benign mesenchymal tumor of the breast. It presents as a well circumscribed, solitary nodular mass, and it has been reported to mainly occur in male patients. To our knowledge, few reports have described the radiologic appearance of myofibroblastoma in the female breast and there has been no report from Korea. We describe the mammographic, sonographic and histologic findings of a case of myofibroblastoma that presented as a well defined mass mimicking fibroadenoma in a 44-year-old woman

  15. Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

    International Nuclear Information System (INIS)

    Yang, Tzu-I. J.; Yang Qifeng; Haffty, Bruce G.; Moran, Meena S.

    2010-01-01

    Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (p o histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.

  16. US and mammographic findings of myofibroblastoma in the female breast: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seog Wan; Jeon, Soo Bin [Chonbuk University Medical College, Jeonju (Korea, Republic of); Lee, Ji Shin [Chonnam University Medicine College, Gwangju (Korea, Republic of); Kim, Dong Sug [Yeungnam University Medicine College, Daegu (Korea, Republic of)

    2005-07-15

    Myofibroblastoma is a rare benign mesenchymal tumor of the breast. It presents as a well circumscribed, solitary nodular mass, and it has been reported to mainly occur in male patients. To our knowledge, few reports have described the radiologic appearance of myofibroblastoma in the female breast and there has been no report from Korea. We describe the mammographic, sonographic and histologic findings of a case of myofibroblastoma that presented as a well defined mass mimicking fibroadenoma in a 44-year-old woman.

  17. Patients Mammographic Dose Survey in a Sample of Slovak Mammography Departments

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Gbelcova, L.

    2008-01-01

    Breast cancer is the most frequent cancer and the most frequent cause of cancer induced deaths in Europe. Demographic trends indicate a continuing increase in this substantial public health problem. Systematic early detection, effective diagnostic pathways and high quality services have the ability for lowering the breast cancer mortality rates and for reducing the burden of this disease in the population The widespread use of mammography for early breast cancer detection is highly accepted all over the world. For achievement of a successful national mammography programme in Slovakia, a national QA/QC mammography system was introduced. Coming from alarming values of increase of malignant neoplasm of breast in Slovakia a national mammography audit has been initiated, performed in three runs and working in three phases: assessment of existing status of practice and equipment performance, as well as education and training of radiologists and radiographers of 42 mammography departments; implementation of technical quality programme and patient dose evaluation; clinical image evaluation. Preventive mammography in spite of being a reasonable examination, which represents health benefit for patient, exceed also the health risk. In 1991-1996 mammographic examination created 1.3% from all medical radiodiagnostic expositions made in Slovakia. In 2005 there were realized 241 208 mammographic examinations, 140 798 of them were noticed like preventive examinations. In 2006 the number of all mammographic examinations in Slovakia increased to 271 755 and of them 156 199 were preventive mammographic examinations. In our presentation we tried to establish the average absorbed glandular doses of patients undergoing mammography examinations in 10 selected departments and to compare the obtained results with European diagnostic reference values. The obtained values were used for the proposal of a new national diagnostic reference value for mammography examinations

  18. Correlation between mammographic findings and corresponding histopathology. Potential predictors for biological characteristics of breast diseases

    International Nuclear Information System (INIS)

    Tamaki, Kentaro; Ishida, Takanori; Miyashita, Minoru; Amari, Masakazu; Ohuchi, Noriaki; Tamaki, Nobumitsu; Sasano, Hironobu

    2011-01-01

    The present study retrospectively evaluated the mammographic findings of 606 Japanese women with breast cancer (median age 50 years; range 27-89 years) and correlated them with histopathological characteristics. Mammographic findings were evaluated with an emphasis on mass shape, margin, density, calcification, and the presence of architectural distortion; these findings were correlated with histopathological characteristics such as intrinsic subtype, histological grade, lymphovascular invasion, and the Ki-67 labeling index. An irregular mass shape and masses with a spiculated margin were significantly higher in the group of patients with luminal A breast cancer than in patients with masses that were lobular or round, or in tumors with an indistinct or microlobulated periphery (P=0.017, P=0.024, P<0.001, and P=0.001, respectively). Irregular mass shape and spiculated periphery were significantly lower in patients with Grade 3 cancer (P<0.001 for both). In terms of lymphovascular invasion, there were significant differences between oval and irregular or round mass shape (P=0.008 and P=0.034), between tumors with a microlobulated and indistinct periphery (P=0.014), between tumors with a punctate and amorphous or pleomorphic calcification shape (P=0.030 and 0.038), and between the presence and absence of architectural distortion (P=0.027). Equivalent or low-density masses were also higher in Grade 1 breast cancers (P=0.007). There were significant differences in the Ki-67 labeling index between irregular and lobular or round tumors (P<0.001 and P=0.014), as well as between spiculated and indistinct or microlobulated tumors (P<0.001 for both). Significant differences were noted in the mammographic features of different primary breast cancer subtypes. These proposed mammographic diagnostic criteria based on biological characteristics may contribute to a more accurate prediction of biological behavior of breast malignancies. (author)

  19. Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Giger, Maryellen L.; Li, Hui [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States); Duewer, Fred; Malkov, Serghei; Joe, Bonnie; Kerlikowske, Karla; Shepherd, John A. [Radiology Department, University of California, San Francisco, California 94143 (United States); Flowers, Chris I. [Department of Radiology, University of South Florida, Tampa, Florida 33612 (United States); Drukteinis, Jennifer S. [Department of Radiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida 33612 (United States)

    2014-03-15

    Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

  20. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Shivaani Mariapun

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. METHODS: A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. RESULTS: Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0% compared to Malay (24.2%; 95% CI 22.5%, 26.0% and Indian (24.3%; 95% CI 22.8%, 25.7% women (p<0.001, after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2 women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2 and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2 women (p<0.001, but dense area did not differ across the three ethnic groups. CONCLUSIONS: Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  1. Ethnic Differences in Mammographic Densities: An Asian Cross-Sectional Study

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Background Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. Methods A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Results Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (p<0.001), after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (p<0.001), but dense area did not differ across the three ethnic groups. Conclusions Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort. PMID:25659139

  2. Effect of strychnine hydrochloride on liver cytochrome P450 mRNA expression and monooxygenase activities in rat

    Directory of Open Access Journals (Sweden)

    Qian Gao

    2011-08-01

    Full Text Available Strychnos nux-vomica L. has been frequently used in traditional Chinese medicine but has high acute toxicity. It is commonly taken with Glycyrrhizae radix to decrease its toxicity but the mechanism of this interaction is unknown. In this work, the mRNA expression and the activity of four cytochrome P450 (CYP enzymes representative of four subfamilies (CYP1A, CYP3A, CYP2C and CYP2E were determined ex vivo in rat livers from groups of Wistar rats orally administered strychnine hydrochloride (SH at three doses (0.1, 0.3 and 0.9 mg/kg/day alone and, at the highest dose, in combination with glycyrrhetinic acid (GA, 25 mg/kg/day or liquiritin (LQ, 20 mg/kg/day once a day for 7 consecutive days. Compared to control, the mRNA expressions of CYP3A1, 1A2 and 2E1 were higher in rats receiving the highest dose of SH but lower for CYP3A1 and CYP2E1 in rats receiving the SH+GA and SH+LQ combinations. CYP2E1 activity was higher and CYP2C, CYP3A and CYP1A2 activities were lower in rats receiving the highest dose of SH. In contrast CYP1A2 and CYP2C activities were higher and CYP2E1 and CYP3A activities lower in rats receiving the SH+GA combination. CYP2E1 and CYP3A activities were also lower in rats receiving the SH+LQ combination. The results show that treatment with SH for 7 days affects the expression and the activity of CYP enzymes and that coadministration of GA and LQ modulates these effects. This modulation may explain the role of Glycyrrhizae radix in reducing the acute toxicity of Strychnos nux-vomica L.CYPs enzymes.

  3. Textural Classification of Mammographic Parenchymal Patterns with the SONNET Selforganizing Neural Network

    Directory of Open Access Journals (Sweden)

    Daniel Howard

    2008-01-01

    Full Text Available In nationwide mammography screening, thousands of mammography examinations must be processed. Each consists of two standard views of each breast, and each mammogram must be visually examined by an experienced radiologist to assess it for any anomalies. The ability to detect an anomaly in mammographic texture is important to successful outcomes in mammography screening and, in this study, a large number of mammograms were digitized with a highly accurate scanner; and textural features were derived from the mammograms as input data to a SONNET selforganizing neural network. The paper discusses how SONNET was used to produce a taxonomic organization of the mammography archive in an unsupervised manner. This process is subject to certain choices of SONNET parameters, in these numerical experiments using the craniocaudal view, and typically produced O(10, for example, 39 mammogram classes, by analysis of features from O(103 mammogram images. The mammogram taxonomy captured typical subtleties to discriminate mammograms, and it is submitted that this may be exploited to aid the detection of mammographic anomalies, for example, by acting as a preprocessing stage to simplify the task for a computational detection scheme, or by ordering mammography examinations by mammogram taxonomic class prior to screening in order to encourage more successful visual examination during screening. The resulting taxonomy may help train screening radiologists and conceivably help to settle legal cases concerning a mammography screening examination because the taxonomy can reveal the frequency of mammographic patterns in a population.

  4. Mammographic density in asymptomatic menopausal women: correlation with clinical and sonographic findings

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2012-06-01

    Full Text Available OBJECTIVE: To evaluate mammographic breast density in asymptomatic menopausal women in correlation with clinical and sonographic findings. MATERIALS AND METHODS: Mammograms and clinical and sonographic findings of 238 asymptomatic patients were retrospectively reviewed in the period from February/2022 to June/2006. The following variables were analyzed: mammographic density patterns, sonographic findings, patients' age, parity, body mass index and use of hormone replacement therapy. RESULTS: Age, parity and body mass index showed a negative correlation with breast density pattern, while use of hormone replacement therapy showed a positive correlation. Supplementary breast ultrasonography was performed in 103 (43.2% patients. Alterations which could not be visualized at mammography were found in 34 (33% of them, most frequently in women with breast density patterns 3 and 4. CONCLUSION: The authors concluded that breast density patterns were influenced by age, parity, body mass index and time of hormone replacement therapy. Despite not having found any malignant abnormality in the studied cases, the authors have observed a predominance of benign sonographic abnormalities in women with high breast density patterns and without mammographic abnormalities, proving the relevance of supplementary ultrasonography to identify breast lesions in such patients.

  5. International Consortium on Mammographic Density: Methodology and Population Diversity captured across 22 Countries

    Science.gov (United States)

    McCormack, Valerie A.; Burton, Anya; dos-Santos-Silva, Isabel; Hipwell, John H.; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Ling Lee, Charmaine Pei; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H.; Wanders, Johanna O.P.; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Lee, Jong Won; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M.; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J.; Schüz, Joachim; Chiarelli, Anna; Linton, Linda; Boyd, Norman F.

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with similar westernized lifestyles living in countries with high breast cancer incidence rates. To benefit from the heterogeneity in risk factors and their combinations worldwide, we created an International Consortium on Mammographic Density (ICMD) to pool individual-level epidemiological and MD data from general population studies worldwide. ICMD aims to characterize determinants of MD more precisely, and to evaluate whether they are consistent across populations worldwide. We included 11755 women, from 27 studies in 22 countries, on whom individual-level risk factor data were pooled and original mammographic images were re-read for ICMD by a core team to obtain standardized comparable MD data. In the present article, we present (i) the rationale for this consortium; (ii) characteristics of the studies and women included; and (iii) study methodology to obtain comparable MD data from original re-read films. We also highlight the risk factor heterogeneity captured by such an effort and, thus, the unique insight the pooled study promises to offer through wider exposure ranges, different confounding structures and enhanced power for sub-group analyses. PMID:26724463

  6. Effect of zolpidem on human cytochrome P450 activity, and on transport mediated by P-glycoprotein.

    Science.gov (United States)

    von Moltke, Lisa L; Weemhoff, James L; Perloff, Michael D; Hesse, Leah M; Harmatz, Jerold S; Roth-Schechter, Barbara F; Greenblatt, David J

    2002-12-01

    The influence of high concentrations of zolpidem (100 microM, corresponding to approximately 200 times maximum therapeutic concentrations) on the activity of six human Cytochrome P450 (CYP) enzymes was evaluated in a model system using human liver microsomes. Zolpidem produced negligible or weak inhibition of human CYP1A2, 2B6, 2C9, 2C19, 2D6, and 3A. Transport of rhodamine 123, presumed to be mediated mainly by the energy-dependent efflux transport protein P-glycoprotein, was studied in a cell culture system using a human intestinal cell line. High concentrations of zolpidem (100 microM), exceeding the usual therapeutic range by more than 100-fold, produced only modest impairment of rhodamine 123 transport. The findings indicate that zolpidem is very unlikely to cause clinical drug interactions attributable to impairment of CYP activity or P-gp mediated transport. Copyright 2002 John Wiley & Sons, Ltd.

  7. Anthropometric parameters: weight height, body mass index and mammary volume in relationship with the mammographic pattern

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Busto, C.; Avila, R.; Marrero, M. G.; Liminana, J. M.; Orengo, J. C.

    2001-01-01

    A prospective study to attempt to relate the anthropometric parameters of height, weight, body mass index as well as age with the mammographic patterns obtained for the patients and obtain an anthropometric profile was carried out. The study was performed in 1.000 women who underwent a mammography in cranial-caudal and medial lateral oblique projection of both breasts, independently of whether they were screened or diagnosed. Prior to the performance of the mammography, weight and height were obtained, and this was also performed by the same technicians, and the patient were asked their bra size to deduce breast volume. With the weight, the body mass index of Quetelet was calculated (weight [kg]/height''2 (ml). After reading the mammography, the patient was assigned to one of the four mammographic patterns considered in the BIRADS (Breast Imaging Reporting and Data System) established by the ACR (American College of Radiology): type I (fat). type II (disperse fibroglandular densities), type III (fibroglandular densities distributed heterogeneously), type 4 (dense). The results were introduced into a computer database and the SPSS 8.0 statistical program was applied, using the statistical model of multivariant logistic regression. In women under 40 years, with normal weight, the dense breast pattern accounted for 67.8% and as the body mass index (BMI) increased, this pattern decreased to 25.1%. The fat pattern is 20% and as the BMI increases, this increased to 80%. In 40-60 year old women with normal weight, the dense pattern accounts for 44% and decreases to 20.9% in the grades II, III and IV obese. The fat pattern is 11.1% and increases to 53.7% in the grade II, III and IV obese. In women over 60 with normal, the dense pattern accounts for 19.3% and and decreases to 13% in the grade III obese. The fat pattern is 5.3% and increases to 20.2% in the grade iii of obesity. As age increases, the probability of presenting a mammographic pattern with a fat image in the

  8. Sclerosing adenosis: mammographic and ultrasonographic findings with clinical and histopathological correlation

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Memis, Aysenur; Uestuen, Esin Emin; Oezdemir, Necmettin; Erhan, Yildiz

    2002-01-01

    Objective: To evaluate the mammographic and ultrasonographic findings of sclerosing adenosis, a relatively uncommon entity which may sometimes mimic carcinoma. Materials and methods: A retrospective review of the records of 33700 women, who have undergone mammographic examination at our institution between January 1985 and July 2001 revealed 43 histopathologically proven sclerosing adenosis. The history, physical examination, mammographic and ultrasonographic findings were analyzed in all patients. In 30 patients, the nonpalpable lesions were preoperatively localized by the needle-hookwire system under the guidance of mammography (n=22) or ultrasonography (US) (n=8). Radiological features were correlated with histopathological findings. Results: The age of the patients varied between 32 and 55 years (mean, 43.7 years). Only two patients had a family history of breast cancer. In six patients, the presenting complaint was mastalgia. A palpable mass was present in 13 cases. The mammographic findings were; microcalcifications in 24 (55.8%) (clustered in 22, diffuse in two), mass in five (11.6%), asymmetric focal density in three (6.9%), and focal architectural distortion in three (6.9%) patients. Four of the masses were irregularly contoured, while one was well-circumscribed. On US, focal acoustic shadowing without a mass configuration was noted in the three patients who showed asymmetrical focal density on mammography. In eight patients, who showed normal mammograms, a solid mass was detected on US. Two masses had discrete well-circumscribed oval or lobulated contours, while six showed microlobulation and irregularity. In one case, the irregularly contoured mass had marked posterior acoustic shadowing. Two of the three patients, who had focal architectural distortion on mammograms, had an irregularly contoured solid mass, while the third presented as focal acoustic shadowing without a mass configuration. Conclusion: Sclerosing adenosis mostly presents as a nonpalpable

  9. Mammographic surveillance in the follow up of early primary breast cancer in England: A cross-sectional survey

    International Nuclear Information System (INIS)

    Greenwood-Haigh, Lesley

    2009-01-01

    Purpose: The aim of this study was to determine current practice in the clinical setting at national and regional level of the use of mammographic surveillance in the follow up of patients surgically treated for early breast cancer. Method: A cross-sectional survey method was employed. Self-administered questionnaires were sent to a random selection of symptomatic breast imaging units representing all the cancer networks in England nationally, and all symptomatic breast imaging units in one cancer network regionally. Questions were designed to determine frequency and duration of mammographic surveillance for patients aged < 50 years and ≥50 years surgically treated by mastectomy or breast conserving surgery and the number of units with protocols based on the risk of local recurrence or development of a new primary breast cancer. Results: The protocols demonstrated a striking diversity in both the frequency and duration of mammographic surveillance; however the variation was less marked regionally. The duration of mammography for patient's aged ≥70 years surgically treated by mastectomy, demonstrated the greatest diversity (range: 0-15 years). Four protocols had regimes tailored to risk. Conclusion: The introduction of protocols based on risk of development of a local recurrence or new primary could prove cost effective by targeting mammographic surveillance to those who would benefit the most. The survey has demonstrated that a 'post-code lottery' exists for both the frequency and duration of mammographic surveillance in this patient group indicating an urgent need for evidence based national guidance.

  10. The implementation of an AR (augmented reality) approach to support mammographic interpretation training: an initial feasibility study

    Science.gov (United States)

    Tang, Qiang; Chen, Yan; Gale, Alastair G.

    2017-03-01

    Appropriate feedback plays an important role in optimising mammographic interpretation training whilst also ensuring good interpretation performance. The traditional keyboard, mouse and workstation technical approach has a critical limitation in providing supplementary image-related information and providing complex feedback in real time. Augmented Reality (AR) provides a possible superior approach in this situation, as feedback can be provided directly overlaying the displayed mammographic images so making a generic approach which can also be vendor neutral. In this study, radiological feedback was dynamically remapped virtually into the real world, using perspective transformation, in order to provide a richer user experience in mammographic interpretation training. This is an initial attempt of an AR approach to dynamically superimpose pre-defined feedback information of a DICOM image on top of a radiologist's view, whilst the radiologist is examining images on a clinical workstation. The study demonstrates the feasibility of the approach, although there are limitations on interactive operations which are due to the hardware used. The results of this fully functional approach provide appropriate feedback/image correspondence in a simulated mammographic interpretation environment. Thus, it is argued that employing AR is a feasible way to provide rich feedback in the delivery of mammographic interpretation training.

  11. Degree of urbanization and mammographic density in Dutch breast cancer screening participants: results from the EPIC-NL cohort.

    Science.gov (United States)

    Emaus, Marleen J; Bakker, Marije F; Beelen, Rob M J; Veldhuis, Wouter B; Peeters, Petra H M; van Gils, Carla H

    2014-12-01

    It has been observed that women living in urban areas have a higher mammographic density (MD) compared to women living in rural areas. This association might be explained by regional differences in reproductive and lifestyle factors or perhaps by variation in exposure to ambient air pollution as air pollution particles have been described to show estrogenic activity. We investigated the association between degree of urbanization and MD, and aimed to unravel the underlying etiology. 2,543 EPIC-NL participants were studied, and general linear models were used. Urbanization was categorized into five categories according to the number of addresses/km(2). Information on reproductive and lifestyle factors was obtained from the recruitment questionnaire. Air pollution exposure was estimated using land-use regression models. MD was expressed as percent density (PD) and dense area (DA), and was quantified using Cumulus. Women living in extremely urbanized areas had a higher PD (21.4%, 95% confidence interval (CI) 20.5-22.3%) compared to women living in not urbanized areas (16.1, 95% CI 14.5-17.8%, P trend air pollution (adjusted PDextremely_urbanized = 22.1%, 95% CI 18.0-26.5% versus adjusted PDnot_urbanized = 16.9%, 95% CI 13.0-21.2, P trend urbanization is associated with MD. The association could not be explained by differences in reproductive and lifestyle factors or by variation in air pollution exposure.

  12. AM-2201 Inhibits Multiple Cytochrome P450 and Uridine 5′-Diphospho-Glucuronosyltransferase Enzyme Activities in Human Liver Microsomes

    Directory of Open Access Journals (Sweden)

    Ju-Hyun Kim

    2017-03-01

    Full Text Available AM-2201 is a synthetic cannabinoid that acts as a potent agonist at cannabinoid receptors and its abuse has increased. However, there are no reports of the inhibitory effect of AM-2201 on human cytochrome P450 (CYP or uridine 5′-diphospho-glucuronosyltransferase (UGT enzymes. We evaluated the inhibitory effect of AM-2201 on the activities of eight major human CYPs (1A2, 2A6, 2B6, 2C8, 2C9, 2C19, 2D6, and 3A4 and six major human UGTs (1A1, 1A3, 1A4, 1A6, 1A9, and 2B7 enzymes in pooled human liver microsomes using liquid chromatography–tandem mass spectrometry to investigate drug interaction potentials of AM-2201. AM-2201 potently inhibited CYP2C9-catalyzed diclofenac 4′-hydroxylation, CYP3A4-catalyzed midazolam 1′-hydroxylation, UGT1A3-catalyzed chenodeoxycholic acid 24-acyl-glucuronidation, and UGT2B7-catalyzed naloxone 3-glucuronidation with IC50 values of 3.9, 4.0, 4.3, and 10.0 μM, respectively, and showed mechanism-based inhibition of CYP2C8-catalyzed amodiaquine N-deethylation with a Ki value of 2.1 μM. It negligibly inhibited CYP1A2, CYP2A6, CYP2B6, CYP2C19, CYP2D6, UGT1A1, UGT1A4, UGT1A6, and UGT1A9 activities at 50 μM in human liver microsomes. These in vitro results indicate that AM-2201 needs to be examined for potential pharmacokinetic drug interactions in vivo due to its potent inhibition of CYP2C8, CYP2C9, CYP3A4, UGT1A3, and UGT2B7 enzyme activities.

  13. Development of a sampling strategy and sample size calculation to estimate the distribution of mammographic breast density in Korean women.

    Science.gov (United States)

    Jun, Jae Kwan; Kim, Mi Jin; Choi, Kui Son; Suh, Mina; Jung, Kyu-Won

    2012-01-01

    Mammographic breast density is a known risk factor for breast cancer. To conduct a survey to estimate the distribution of mammographic breast density in Korean women, appropriate sampling strategies for representative and efficient sampling design were evaluated through simulation. Using the target population from the National Cancer Screening Programme (NCSP) for breast cancer in 2009, we verified the distribution estimate by repeating the simulation 1,000 times using stratified random sampling to investigate the distribution of breast density of 1,340,362 women. According to the simulation results, using a sampling design stratifying the nation into three groups (metropolitan, urban, and rural), with a total sample size of 4,000, we estimated the distribution of breast density in Korean women at a level of 0.01% tolerance. Based on the results of our study, a nationwide survey for estimating the distribution of mammographic breast density among Korean women can be conducted efficiently.

  14. Association of Catechol-O-methyltransferase polymorphism Val158Met and mammographic density: A meta-analysis.

    Science.gov (United States)

    Kallionpää, Roope A; Uusitalo, Elina; Peltonen, Juha

    2017-08-15

    The Val158Met polymorphism in catechol-O-methyltransferase (COMT) enzyme reduces the methylation of catechol estrogens, which may affect mammographic density. High mammographic density is a known risk factor of breast cancer. Our aim was to perform meta-analysis of the effect of COMT Val158Met polymorphism on mammographic density. Original studies reporting data on mammographic density, stratified by the presence of COMT Val158Met polymorphism, were identified and combined using genetic models Met/Val vs. Val/Val, Met/Met vs. Val/Val, Val/Met+Met/Met vs. Val/Val (dominant model) and Met/Met vs. Val/Met+Val/Val (recessive model). Subgroup analyses by breast cancer status, menopausal status and use of hormone replacement therapy (HRT) were also performed. Eight studies were included in the meta-analysis. The overall effect in percent mammographic density was -1.41 (CI -2.86 to 0.05; P=0.06) in the recessive model. Exclusion of breast cancer patients increased the effect size to -1.93 (CI -3.49 to -0.37; P=0.02). The results suggested opposite effect of COMT Val158Met for postmenopausal users of HRT versus premenopausal women or postmenopausal non-users of HRT. COMT Val158Met polymorphism may be associated with mammographic density at least in healthy women. Menopausal status and HRT should be taken into account in future studies to avoid masking of the underlying effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Impact of contra-lateral breast reshaping on mammographic surveillance in women undergoing breast reconstruction following mastectomy for breast cancer.

    Science.gov (United States)

    Nava, Maurizio B; Rocco, Nicola; Catanuto, Giuseppe; Falco, Giuseppe; Capalbo, Emanuela; Marano, Luigi; Bordoni, Daniele; Spano, Andrea; Scaperrotta, Gianfranco

    2015-08-01

    The ultimate goal of breast reconstruction is to achieve symmetry with the contra-lateral breast. Contra-lateral procedures with wide parenchymal rearrangements are suspected to impair mammographic surveillance. This study aims to evaluate the impact on mammographic detection of mastopexies and breast reductions for contralateral adjustment in breast reconstruction. We retrospectively evaluated 105 women affected by uni-lateral breast cancer who underwent mastectomy and immediate two-stage reconstruction between 2002 and 2007. We considered three groups according to the contra-lateral reshaping technique: mastopexy or breast reduction with inferior dermoglandular flap (group 1); mastopexy or breast reduction without inferior dermoglandular flap (group 2); no contra-lateral reshaping (group 3). We assessed qualitative mammographic variations and breast density in the three groups. Statistically significant differences have been found when comparing reshaped groups with non reshaped groups regarding parenchymal distortions, skin thickening and stromal edema, but these differences did not affect cancer surveillance. The surveillance mammography diagnostic accuracy in contra-lateral cancer detection was not significantly different between the three groups (p = 0.56), such as the need for MRI for equivocal findings at mammographic contra-lateral breast (p = 0.77) and the need for core-biopsies to confirm mammographic suspect of contra-lateral breast cancer (p = 0.90). This study confirms previous reports regarding the safety of mastopexies and breast reductions when performed in the setting of contra-lateral breast reshaping after breast reconstruction. Mammographic accuracy, sensitivity and specificity are not affected by the glandular re-arrangement. These results provide a further validation of the safety of current reconstructive paradigms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Association of mammographic image feature change and an increasing risk trend of developing breast cancer: an assessment

    Science.gov (United States)

    Tan, Maxine; Leader, Joseph K.; Liu, Hong; Zheng, Bin

    2015-03-01

    We recently investigated a new mammographic image feature based risk factor to predict near-term breast cancer risk after a woman has a negative mammographic screening. We hypothesized that unlike the conventional epidemiology-based long-term (or lifetime) risk factors, the mammographic image feature based risk factor value will increase as the time lag between the negative and positive mammography screening decreases. The purpose of this study is to test this hypothesis. From a large and diverse full-field digital mammography (FFDM) image database with 1278 cases, we collected all available sequential FFDM examinations for each case including the "current" and 1 to 3 most recently "prior" examinations. All "prior" examinations were interpreted negative, and "current" ones were either malignant or recalled negative/benign. We computed 92 global mammographic texture and density based features, and included three clinical risk factors (woman's age, family history and subjective breast density BIRADS ratings). On this initial feature set, we applied a fast and accurate Sequential Forward Floating Selection (SFFS) feature selection algorithm to reduce feature dimensionality. The features computed on both mammographic views were individually/ separately trained using two artificial neural network (ANN) classifiers. The classification scores of the two ANNs were then merged with a sequential ANN. The results show that the maximum adjusted odds ratios were 5.59, 7.98, and 15.77 for using the 3rd, 2nd, and 1st "prior" FFDM examinations, respectively, which demonstrates a higher association of mammographic image feature change and an increasing risk trend of developing breast cancer in the near-term after a negative screening.

  17. Inhibitory effects of cytostatically active 6-aminobenzo[c]phenanthridines on cytochrome P450 enzymes in human hepatic microsomes.

    Science.gov (United States)

    Zebothsen, Inga; Kunze, Thomas; Clement, Bernd

    2006-07-01

    Besides assays for the evaluation of efficacy new drug candidates have to undergo extensive testings for enhancement of pharmaceutical drug safety and optimization of application. The objective of the present work was to investigate the pharmacokinetic drug drug interaction potential for the cytostatically active 6-aminobenzo[c]phenanthridines BP-11 (6-amino-11,12-dihydro-11-(4-hydroxy-3,5-dimethoxyphenyl)benzo[c]phenanthridine) and BP-D7 (6-amino-11-(3,4,5-trimethoxyphenyl)benzo[c]phenanthridine) in vitro through incubation with human hepatic microsomes and marker substrates. For these studies the cytochrome P-450 isoenzymes and corresponding marker substrates recommended by the EMEA (The European Agency for the Evaluation of Medicinal Products) were chosen. In detail these selective substrates were caffeine (CYP1A2), coumarin (CYP2A6), tolbutamide (CYP2C9), S-(+)-mephenytoin (CYP2C19), dextromethorphane (CYP2D6), chlorzoxazone (CYP2E1) and testosterone (CYP3A4). Incubations with each substrate were carried out without a possible inhibitor and in the presence of a benzo[c]phenanthridine or a selective inhibitor at varying concentrations. Marker activities were determined by HPLC (high performance liquid chromatography). For the isoenzymes showing more than 50% inhibition by the addition of 20 microM BP-11 or BP-D7 additional concentrations of substrate and inhibitor were tested for a characterization of the inhibition. The studies showed a moderate risk for BP-11 for interactions with the cytochrome P-450 isoenzymes CYP1A2, CYP2C9, CYP2D6 and CYP3A4. BP-D7, the compound with the highest cytotstatic efficacy, showed only a moderate risk for interactions with drugs, also metabolized by CYP3A4.

  18. Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

    International Nuclear Information System (INIS)

    Malkov, Serghei; Wang, Jeff; Kerlikowske, Karla; Cummings, Steven R.; Shepherd, John A.

    2009-01-01

    Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a ±2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

  19. Mammographic density and breast cancer risk by family history in women of white and Asian ancestry.

    Science.gov (United States)

    Maskarinec, Gertraud; Nakamura, Kaylae L; Woolcott, Christy G; Conroy, Shannon M; Byrne, Celia; Nagata, Chisato; Ursin, Giske; Vachon, Celine M

    2015-04-01

    Mammographic density, i.e., the radiographic appearance of the breast, is a strong predictor of breast cancer risk. To determine whether the association of breast density with breast cancer is modified by a first-degree family history of breast cancer (FHBC) in women of white and Asian ancestry, we analyzed data from four case-control studies conducted in the USA and Japan. The study population included 1,699 breast cancer cases and 2,422 controls, of whom 45% reported white (N = 1,849) and 40% Asian (N = 1,633) ancestry. To standardize mammographic density assessment, a single observer re-read all mammograms using one type of interactive thresholding software. Logistic regression was applied to estimate odds ratios (OR) while adjusting for confounders. Overall, 496 (12%) of participants reported a FHBC, which was significantly associated with breast cancer risk in the adjusted model (OR 1.51; 95% CI 1.23-1.84). There was a statistically significant interaction on a multiplicative scale between FHBC and continuous percent density (per 10 % density: p = 0.03). The OR per 10% increase in percent density was higher among women with a FHBC (OR 1.30; 95% CI 1.13-1.49) than among those without a FHBC (OR 1.14; 1.09-1.20). This pattern was apparent in whites and Asians. The respective ORs were 1.45 (95% CI 1.17-1.80) versus 1.22 (95% CI 1.14-1.32) in whites, whereas the values in Asians were only 1.24 (95% CI 0.97-1.58) versus 1.09 (95% CI 1.00-1.19). These findings support the hypothesis that women with a FHBC appear to have a higher risk of breast cancer associated with percent mammographic density than women without a FHBC.

  20. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  1. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Mark, E-mail: marktknox@gmail.com; O’Brien, Angela, E-mail: angelaobrien@doctors.org.uk; Szabó, Endre, E-mail: endrebacsi@freemail.hu; Smith, Clare S., E-mail: csmith@mater.ie; Fenlon, Helen M., E-mail: helen.fenlon@cancerscreening.ie; McNicholas, Michelle M., E-mail: michelle.mcnicholas@cancerscreening.ie; Flanagan, Fidelma L., E-mail: fidelma.flanagan@cancerscreening.ie

    2015-06-15

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications.

  2. Smoking and high-risk mammographic parenchymal patterns: a case-control study

    International Nuclear Information System (INIS)

    Sala, Evis; Warren, Ruth; McCann, Jenny; Duffy, Stephen; Luben, Robert; Day, Nicholas

    2000-01-01

    Current smoking was strongly and inversely associated with high-risk patterns, after adjustment for concomitant risk factors. Relative to never smokers, current smokers were significantly less likely to have a high-risk pattern. Similar results were obtained when the analysis was confined to postmenopausal women. Past smoking was not related to the mammographic parenchymal patterns. The overall effect in postmenopausal women lost its significance when adjusted for other risk factors for P2/DY patterns that were found to be significant in the present study, although the results are still strongly suggestive. The present data indicate that adjustment for current smoking status is important when evaluating the relationship between mammographic parenchymal pattern and breast cancer risk. They also indicate that smoking is a prominent potential confounder when analyzing effects of other risk factors such as obesity-related variables. It appears that parenchymal patterns may act as an informative biomarker of the effect of cigarette smoking on breast cancer risk. Overall, epidemiological studies [1,2,3,4] have reported no substantial association between cigarette smoking and the risk of breast cancer. Some studies [5,6,7] reported a significant increase of breast cancer risk among smokers. In recent studies that addressed the association between breast cancer and cigarette smoking, however, there was some suggestion of a decreased risk [8,9,10], especially among current smokers, ranging from approximately 10 to 30% [9,10]. Brunet et al [11] reported that smoking might reduce the risk of breast cancer by 44% in carriers of BRCA1 or BRCA2 gene mutations. Wolfe [12] described four different mammographic patterns created by variations in the relative amounts of fat, epithelial and connective tissue in the breast, designated N1, P1, P2 and DY. Women with either P2 or DY pattern are considered at greater risk for breast cancer than those with N1 or P1 pattern [12

  3. Varying performance in mammographic interpretation across two countries: Do results indicate reader or population variances?

    Science.gov (United States)

    Soh, BaoLin P.; Lee, Warwick B.; Wong, Jill; Sim, Llewellyn; Hillis, Stephen L.; Tapia, Kriscia A.; Brennan, Patrick C.

    2016-03-01

    Aim: To compare the performance of Australian and Singapore breast readers interpreting a single test-set that consisted of mammographic examinations collected from the Australian population. Background: In the teleradiology era, breast readers are interpreting mammographic examinations from different populations. The question arises whether two groups of readers with similar training backgrounds, demonstrate the same level of performance when presented with a population familiar only to one of the groups. Methods: Fifty-three Australian and 15 Singaporean breast radiologists participated in this study. All radiologists were trained in mammogram interpretation and had a median of 9 and 15 years of experience in reading mammograms respectively. Each reader interpreted the same BREAST test-set consisting of sixty de-identified mammographic examinations arising from an Australian population. Performance parameters including JAFROC, ROC, case sensitivity as well as specificity were compared between Australian and Singaporean readers using a Mann Whitney U test. Results: A significant difference (P=0.036) was demonstrated between the JAFROC scores of the Australian and Singaporean breast radiologists. No other significant differences were observed. Conclusion: JAFROC scores for Australian radiologists were higher than those obtained by the Singaporean counterparts. Whilst it is tempting to suggest this is down to reader expertise, this may be a simplistic explanation considering the very similar training and audit backgrounds of the two populations of radiologists. The influence of reading images that are different from those that radiologists normally encounter cannot be ruled out and requires further investigation, particularly in the light of increasing international outsourcing of radiologic reporting.

  4. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    International Nuclear Information System (INIS)

    Knox, Mark; O’Brien, Angela; Szabó, Endre; Smith, Clare S.; Fenlon, Helen M.; McNicholas, Michelle M.; Flanagan, Fidelma L.

    2015-01-01

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications

  5. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  6. Risk stratification of women with false-positive test results in mammography screening based on mammographic morphology and density

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Lynge, Elsebeth

    2017-01-01

    a case-control study nested in the population-based screening programme in Copenhagen, Denmark. We included 288 cases and 288 controls based on a cohort of 4743 women with at least one FP-test result in 1991–2005 who were followed up until 17 April 2008. Film-based mammograms were assessed using...... the Breast Imaging-Reporting and Data System (BI-RADS) density classification, the Tabár classification, and two automated techniques quantifying percentage mammographic density (PMD) and mammographic texture (MTR), respectively. The association with breast cancer was estimated using binary logistic...

  7. Comparison of Mammographic Changes Across Three Different Fractionation Schedules for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Sibo [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Paster, Lina F. [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Kim, Sinae [Biometrics Division, Rutgers Cancer Institute of New Jersey, and Department of Biostatistics, Rutgers School of Public Health, Rutgers, New Jersey (United States); Kirstein, Laurie [Division of Surgical Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Haffty, Bruce G.; Ferro, Adam [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Amorosa, Judith [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Goyal, Sharad, E-mail: goyalsh@rutgers.edu [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States)

    2016-06-01

    Purpose: As the use of hypofractionated breast radiation therapy (RT) increases, so will the need for long-term data on post-RT mammographic changes. The purpose of the present study was to longitudinally compare the incidence of common mammographic sequelae seen after breast conserving surgery and RT in patients treated with accelerated partial breast irradiation (APBI), hypofractionated whole breast irradiation (HWBI), and conventionally fractionated whole breast irradiation (WBI). Methods and Materials: Patients treated with either APBI or HWBI after breast conserving therapy and with ≥3 mammograms of the treated breast were identified. They were matched 1:1 by age ±5 years to patients treated with WBI. The mammograms were evaluated for common post-RT breast findings by a mammographer who was unaware of the treatment. The outcomes were analyzed using a cumulative logistic regression model; P<.05 indicated statistically significance. Results: Of 89 patients treated with RT from 2006 to 2011, 29 had received APBI, 30 had received HWBI, and 30 had received WBI. Their median age was 60 years (range 33-83). A total of 605 mammograms were evaluated, with a median follow-up of 48 months. The treatment technique did not affect the severity of architectural distortion when the groups were evaluated longitudinally. The likelihood of finding skin thickening decreased with increasing follow-up duration (odds ratio 0.6; P<.001) adjusted for fractionation schemes. No differences were seen with respect to changes in skin thickening, fluid collections, or calcifications among the treatment groups, after adjustment for the follow-up time. The clinical characteristics, including age, race, T stage, and chemotherapy use, were not linked to the likelihood of finding several mammographic phenomena over time. Conclusions: Although specific post-treatment imaging findings evolved over time, RT fractionation did not alter the relative incidence or severity of architectural

  8. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  9. The combined effect of mammographic texture and density on breast cancer risk: a cohort study.

    Science.gov (United States)

    Wanders, Johanna O P; van Gils, Carla H; Karssemeijer, Nico; Holland, Katharina; Kallenberg, Michiel; Peeters, Petra H M; Nielsen, Mads; Lillholm, Martin

    2018-05-02

    Texture patterns have been shown to improve breast cancer risk segregation in addition to area-based mammographic density. The additional value of texture pattern scores on top of volumetric mammographic density measures in a large screening cohort has never been studied. Volumetric mammographic density and texture pattern scores were assessed automatically for the first available digital mammography (DM) screening examination of 51,400 women (50-75 years of age) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. The texture assessment method was developed in a previous study and validated in the current study. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. All screen-detected breast cancers diagnosed at the first available digital screening examination were excluded. During a median follow-up period of 4.2 (interquartile range (IQR) 2.0-6.2) years, 301 women were diagnosed with breast cancer. The associations between texture pattern scores, volumetric breast density measures and breast cancer risk were determined using Cox proportional hazard analyses. Discriminatory performance was assessed using c-indices. The median age of the women at the time of the first available digital mammography examination was 56 years (IQR 51-63). Texture pattern scores were positively associated with breast cancer risk (hazard ratio (HR) 3.16 (95% CI 2.16-4.62) (p value for trend <0.001), for quartile (Q) 4 compared to Q1). The c-index of texture was 0.61 (95% CI 0.57-0.64). Dense volume and percentage dense volume showed positive associations with breast cancer risk (HR 1.85 (95% CI 1.32-2.59) (p value for trend <0.001) and HR 2.17 (95% CI 1.51-3.12) (p value for trend <0.001), respectively, for Q4 compared to Q1). When adding texture measures to models with dense volume or percentage dense volume, c-indices increased from 0.56 (95% CI 0.53-0.59) to 0

  10. Mammographic texture resemblance generalizes as an independent risk factor for breast cancer

    DEFF Research Database (Denmark)

    Nielsen, Mads; Vachon, Celine M.; Scott, Christopher G.

    2014-01-01

    INTRODUCTION:Breast density has been established as a major risk factor for breast cancer. We have previously demonstrated that mammographic texture resemblance (MTR), recognizing the local texture patterns of the mammogram, is also a risk factor for breast cancer, independent of percent breast...... density. We examine if these findings generalize to another population.METHODS:Texture patterns were recorded in digitalized pre-diagnosis (3.7years) film mammograms of a nested case-control study within the Dutch screening program (S1) comprising of 245 breast cancers and 250 matched controls...

  11. Combining different views of mammographic texture resemblance (MTR) marker of breast cancer risk

    DEFF Research Database (Denmark)

    Sun, S.; Karemore, Gopal; Chernoff, Konstantin

    the subsequent 4 years whereas 245 cases had a diagnosis 2-4 years post mammography. We employed the MTR supervised texture learning framework to perform risk evaluation from a single mammography view. In the framework 20,000 pixels were sampled and classified by a kNN pixel classifier. A feature selection step......PURPOSE Mammographic density is a well established breast cancer risk factor. Texture analysis in terms of the Mammographoc Texture Resemblance (MTR) marker has recently shown to add to risk segregation. Hitherto only single view MTR analysis has been performed. Standard mammography examinations...

  12. A comparison of five methods of measuring mammographic density: a case-control study.

    Science.gov (United States)

    Astley, Susan M; Harkness, Elaine F; Sergeant, Jamie C; Warwick, Jane; Stavrinos, Paula; Warren, Ruth; Wilson, Mary; Beetles, Ursula; Gadde, Soujanya; Lim, Yit; Jain, Anil; Bundred, Sara; Barr, Nicola; Reece, Valerie; Brentnall, Adam R; Cuzick, Jack; Howell, Tony; Evans, D Gareth

    2018-02-05

    High mammographic density is associated with both risk of cancers being missed at mammography, and increased risk of developing breast cancer. Stratification of breast cancer prevention and screening requires mammographic density measures predictive of cancer. This study compares five mammographic density measures to determine the association with subsequent diagnosis of breast cancer and the presence of breast cancer at screening. Women participating in the "Predicting Risk Of Cancer At Screening" (PROCAS) study, a study of cancer risk, completed questionnaires to provide personal information to enable computation of the Tyrer-Cuzick risk score. Mammographic density was assessed by visual analogue scale (VAS), thresholding (Cumulus) and fully-automated methods (Densitas, Quantra, Volpara) in contralateral breasts of 366 women with unilateral breast cancer (cases) detected at screening on entry to the study (Cumulus 311/366) and in 338 women with cancer detected subsequently. Three controls per case were matched using age, body mass index category, hormone replacement therapy use and menopausal status. Odds ratios (OR) between the highest and lowest quintile, based on the density distribution in controls, for each density measure were estimated by conditional logistic regression, adjusting for classic risk factors. The strongest predictor of screen-detected cancer at study entry was VAS, OR 4.37 (95% CI 2.72-7.03) in the highest vs lowest quintile of percent density after adjustment for classical risk factors. Volpara, Densitas and Cumulus gave ORs for the highest vs lowest quintile of 2.42 (95% CI 1.56-3.78), 2.17 (95% CI 1.41-3.33) and 2.12 (95% CI 1.30-3.45), respectively. Quantra was not significantly associated with breast cancer (OR 1.02, 95% CI 0.67-1.54). Similar results were found for subsequent cancers, with ORs of 4.48 (95% CI 2.79-7.18), 2.87 (95% CI 1.77-4.64) and 2.34 (95% CI 1.50-3.68) in highest vs lowest quintiles of VAS, Volpara and Densitas

  13. Mammographic and sonographic findings of unilateral breast edema in congestive heart failure : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Lee, Seung Koo; Oh, Ki Keun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-06-01

    Unilateral breast edema has many causes, though among these, congestive heart failure is rare. We report mammographic and sonographic findings of unilateral breast edema due to congestive heart failure. Mammography showed diffuse increase density and skin thickening but no evidence of mass or calcification. Ultrasonography showed skin thickening and increased echogenicity in the subcutaneous fat layer, while in the dermal layer, with tubular and reticular anechoic structures suggestive of dilated lymphatics were seen. After treatment of the heart failure, resolution of the abnormalities seen on mammogram established that these were secondary findings.

  14. Mammographic and sonographic findings of unilateral breast edema in congestive heart failure : a case report

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Seung Koo; Oh, Ki Keun

    1997-01-01

    Unilateral breast edema has many causes, though among these, congestive heart failure is rare. We report mammographic and sonographic findings of unilateral breast edema due to congestive heart failure. Mammography showed diffuse increase density and skin thickening but no evidence of mass or calcification. Ultrasonography showed skin thickening and increased echogenicity in the subcutaneous fat layer, while in the dermal layer, with tubular and reticular anechoic structures suggestive of dilated lymphatics were seen. After treatment of the heart failure, resolution of the abnormalities seen on mammogram established that these were secondary findings

  15. Volumetric mammographic density: heritability and association with breast cancer susceptibility loci.

    Science.gov (United States)

    Brand, Judith S; Humphreys, Keith; Thompson, Deborah J; Li, Jingmei; Eriksson, Mikael; Hall, Per; Czene, Kamila

    2014-12-01

    Mammographic density is a strong heritable trait, but data on its genetic component are limited to area-based and qualitative measures. We studied the heritability of volumetric mammographic density ascertained by a fully-automated method and the association with breast cancer susceptibility loci. Heritability of volumetric mammographic density was estimated with a variance component model in a sib-pair sample (N pairs = 955) of a Swedish screening based cohort. Associations with 82 established breast cancer loci were assessed in an independent sample of the same cohort (N = 4025 unrelated women) using linear models, adjusting for age, body mass index, and menopausal status. All tests were two-sided, except for heritability analyses where one-sided tests were used. After multivariable adjustment, heritability estimates (standard error) for percent dense volume, absolute dense volume, and absolute nondense volume were 0.63 (0.06) and 0.43 (0.06) and 0.61 (0.06), respectively (all P associated with rs10995190 (ZNF365; P = 9.0 × 10(-6) and 8.9 × 10(-7), respectively) and rs9485372 (TAB2; P = 1.8 × 10(-5) and 1.8 × 10(-3), respectively). We also observed associations of rs9383938 (ESR1) and rs2046210 (ESR1) with the absolute dense volume (P = 2.6 × 10(-4) and 4.6 × 10(-4), respectively), and rs6001930 (MLK1) and rs17356907 (NTN4) with the absolute nondense volume (P = 6.7 × 10(-6) and 8.4 × 10(-5), respectively). Our results support the high heritability of mammographic density, though estimates are weaker for absolute than percent dense volume. We also demonstrate that the shared genetic component with breast cancer is not restricted to dense tissues only. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Mucinous (colloid) breast cancer: mammographic and US features with histologic correlation

    International Nuclear Information System (INIS)

    Memis, Aysenur; Ozdemir, Necmettin; Parildar, Mustafa; Ustun, Esin Emin; Erhan, Yildiz

    2000-01-01

    Objective: Mucinous carcinoma of the breast presents with different survival rates in pure and mixed types. The purpose of this study was to correlate the mammographic and ultrasonographic findings of mucinous carcinoma with histologic features in different types and mucin rates. Material and methods: Thirty-four patients (2.3%) had mucinous cancer after retrospective review of the 1439 breast cancers diagnosed between 1990 and 1996. Twenty-seven patients, 19 pure and eight mixed type of mucinous carcinomas of the breast, were included in this study to evaluate the imaging findings. In 22 of these, the microscopic slides were available and re-evaluated to estimate the volume of extracellular mucin. The volume of the extracellular mucin was classified histologically as: (+), less than 50% of mucin; (++), 50-80% of mucin; and (+++), more than 80% of mucin. Mammographic features with emphasis on margin characteristics and sonographic echo pattern of tumors were correlated with histologic findings. Results: Ten cases (53%) of pure mucinous type carcinomas had a circumscribed mass lesion on the mammograms. The well-defined, lobulated margins of the masses were well correlated with pure histologic type (P 2 analysis) Two-thirds of these tumors had high volume extracellular mucin. All mixed type mucinous carcinomas demonstrated poorly defined or spiculated margins with no relation to the mucin rates (P<0.01). The sonographic appearances of the tumors showed correlation with histologic types. Most of the pure type carcinomas (53%) were seen with isoechogenic echo texture relative to that of subcutaneous fat, while all of the mixed type carcinomas were hypoechogenic (P<0.01). Conclusion: The mammographic and sonographic features of mucinous breast carcinoma show differences in pure and mixed types of the tumor. The most common mammographic appearance of pure mucinous carcinomas with high percentages of mucin is a mass lesion having well-defined margins, which is

  17. In vitro inhibitory activities of the extract of Hibiscus sabdariffa L. (family Malvaceae) on selected cytochrome P450 isoforms.

    Science.gov (United States)

    Johnson, Showande Segun; Oyelola, Fakeye Titilayo; Ari, Tolonen; Juho, Hokkanen

    2013-01-01

    Literature is scanty on the interaction potential of Hibiscus sabdariffa L., plant extract with other drugs and the affected targets. This study was conducted to investigate the cytochrome P450 (CYP) isoforms that are inhibited by the extract of Hibiscus sabdariffa L. in vitro. The inhibition towards the major drug metabolizing CYP isoforms by the plant extract were estimated in human liver microsomal incubations, by monitoring the CYP-specific model reactions through previously validated N-in-one assay method. The ethanolic extract of Hibiscus sabdariffa showed inhibitory activities against nine selected CYP isoforms: CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1 and CYP3A4. The concentrations of the extract which produced 50% inhibition of the CYP isoforms ranged from 306 µg/ml to 1660 µg/ml, and the degree of inhibition based on the IC50 values for each CYP isoform was in the following order: CYP1A2 > CYP2C8 > CYP2D6 > CYP2B6 > CYP2E1 > CYP2C19 > CYP3A4 > CYP2C9 > CYP2A6. Ethanolic extract of Hibiscus sabdariffa caused inhibition of CYP isoforms in vitro. These observed inhibitions may not cause clinically significant herb-drug interactions; however, caution may need to be taken in co-administering the water extract of Hibiscus sabdariffa with other drugs until clinical studies are available to further clarify these findings.

  18. Clinicopathogical characteristics and mammographic features of breast cancer showing architectural distortion on a mammogram

    International Nuclear Information System (INIS)

    Kanzaki, Masao; Hirose, Naoko; Suwa, Kaori; Yoshida, Masayuki; Otuki, Yoshiro; Kobayashi, Hiroshi

    2012-01-01

    Seven hundred and twenty-seven cases of breast cancer were diagnosed in this clinic between January 2003 and December 2010. Of those, 97 patients who showed architectural distortion on mammography were examined regarding the clinicopathological characteristics and mammographic features. The overall rate of architectural distortion was 13.3%, which became higher with progression of the clinical stage. The rate of lymph node metastasis was 50.5% histologically, and the most common histological type was scirrhous carcinoma at 36.2%, papillotubular carcinoma at 33%, invasive lobular carcinoma at 12.1%, and ductal carcinoma in situ at 11%. Cases of extensive ductal spread beyond the breast quadrant, accompanied by microcalcifications or showing architectural distortion in two views on mammography, were present at significantly high rates. Cases showing architectural distortion in two views on mammography accounted for 66% of the total, and, when these cases were not associated with any other mammographic findings, the most suspected histology of the lesion was invasive lobular carcinoma or carcinoma in situ. (author)

  19. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    Science.gov (United States)

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  20. The power and the pain: Mammographic compression research from the service-users' perspective

    International Nuclear Information System (INIS)

    Robinson, Leslie; Hogg, Peter; Newton-Hughes, Ann

    2013-01-01

    Purpose: to explore the value service-users can add to our understanding of inter-practitioner compression variability in mammography. Imaging of the breast for the screening and detection of breast carcinoma is generally carried out by mammographic examination the technique for which includes compression of the breast. Evolving research calls into question compression practice in terms of practitioner consistency thus raising the possibility that strong compression may not be required. We were interested to know whether this was important to service-users and if such knowledge might influence their behaviour. Methods: and sample: A qualitative study involving 3 focus groups interviews (n = 4, 6 and 5). Participants were first asked to reflect on their own experiences of breast compression within the context of a breast screening examination, then interpret the results of the evolving research detailed above. We then explored whether these participants might behave differently during future mammography in light being appraised of these research findings. Results: A grounded approach was used to analyse the data into themes. The two overarching themes were i) Service-User Empowerment, which illustrates the difficulties participants believe women would encounter in exercising power in the breast screening mammographic examination; and ii) Service User Experience of Mammography, which unearthed unanticipated aspects of the examination, other than compression, that contribute to pain and discomfort and which therefore need investigation. Conclusion: Involving service-users more collaboratively in research can help investigators understand the impact of their work and highlight patient-relevant areas for further investigation

  1. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Image enhancement by using IDL for a mammographic x-ray image in Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Md Saion Salikin; Wan Hazlinda Ismail; Norriza Mohd Isa; Azuhar Ripin

    2004-01-01

    Digital image enhancement technique can have a significant impact on the diagnostic quality of a radiographic image. The main aim of image enhancement is to process the image so that the enhanced image is clearer and more useful for specific application. There are three types of image enhancement namely noise reduction, edge enhancement and contrast enhancement. The objective of this project is to enhance the mammographic image by using Interactive Data Language (IDL) software in spatial and frequency domain by using various methods. In spatial domain method, direct manipulation of pixel in an image is used whereas, in frequency domain method, modifying the spectral component or Fourier Transform of an image is used In order to obtain the good quality mammographic image, breast phantom Model 12A with 4.0 cm compressed thickness and Bennett Model DMF- 150 Mammography Machine with various kV and mA are employed. The results of enhanced image with selected technique by using IDL are presented in this paper. (Author)

  3. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  4. Mammographic features and misdiagnosed analysis on 92 cases with breast cancer

    International Nuclear Information System (INIS)

    Liu Mingjuan; Zhang Xiaoling; Guo Yan

    2010-01-01

    Objective: To investigate the atypical X-ray features in breast cancer and improve the accuracy of diagnosis. Methods: Mammographic features of 92 cases with pathologically confirmed breast cancer were analyzed retrospectively. Results: High-density mass with speculated margined, clusters of small calcification, stellate-like lesions were found in 51 cases, the rate of correct diagnosis was 96%-100%. Lobulated high-density mass were found in 17 cases, the correct diagnosis rate was about 88.3% cases with skin thickening were all correctly diagnosed. Round mass, focal parenchymal asymmetry and unidentified lesions were found in 20 cases, the diagnosing rate was less than 20%. Conclusion: Round mass, focal parenchymal asymmetry and unidentified lesions were atypical mammographic features of breast cancer. These lesions were misdiagnosed frequently. It is essential to find the indirect signs and associated finding to avoid misdiagnosis. On the other hand, further ultrasound or MRI were helpful to improve the diagnosis by detecting mass in breast, showing cystic lesions and blood supply. (authors)

  5. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  6. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    Science.gov (United States)

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  7. Identification of a novel percent mammographic density locus at 12q24.

    Science.gov (United States)

    Stevens, Kristen N; Lindstrom, Sara; Scott, Christopher G; Thompson, Deborah; Sellers, Thomas A; Wang, Xianshu; Wang, Alice; Atkinson, Elizabeth; Rider, David N; Eckel-Passow, Jeanette E; Varghese, Jajini S; Audley, Tina; Brown, Judith; Leyland, Jean; Luben, Robert N; Warren, Ruth M L; Loos, Ruth J F; Wareham, Nicholas J; Li, Jingmei; Hall, Per; Liu, Jianjun; Eriksson, Louise; Czene, Kamila; Olson, Janet E; Pankratz, V Shane; Fredericksen, Zachary; Diasio, Robert B; Lee, Adam M; Heit, John A; DeAndrade, Mariza; Goode, Ellen L; Vierkant, Robert A; Cunningham, Julie M; Armasu, Sebastian M; Weinshilboum, Richard; Fridley, Brooke L; Batzler, Anthony; Ingle, James N; Boyd, Norman F; Paterson, Andrew D; Rommens, Johanna; Martin, Lisa J; Hopper, John L; Southey, Melissa C; Stone, Jennifer; Apicella, Carmel; Kraft, Peter; Hankinson, Susan E; Hazra, Aditi; Hunter, David J; Easton, Douglas F; Couch, Fergus J; Tamimi, Rulla M; Vachon, Celine M

    2012-07-15

    Percent mammographic density adjusted for age and body mass index (BMI) is one of the strongest risk factors for breast cancer and has a heritable component that remains largely unidentified. We performed a three-stage genome-wide association study (GWAS) of percent mammographic density to identify novel genetic loci associated with this trait. In stage 1, we combined three GWASs of percent density comprised of 1241 women from studies at the Mayo Clinic and identified the top 48 loci (99 single nucleotide polymorphisms). We attempted replication of these loci in 7018 women from seven additional studies (stage 2). The meta-analysis of stage 1 and 2 data identified a novel locus, rs1265507 on 12q24, associated with percent density, adjusting for age and BMI (P = 4.43 × 10(-8)). We refined the 12q24 locus with 459 additional variants (stage 3) in a combined analysis of all three stages (n = 10 377) and confirmed that rs1265507 has the strongest association in the 12q24 region (P = 1.03 × 10(-8)). Rs1265507 is located between the genes TBX5 and TBX3, which are members of the phylogenetically conserved T-box gene family and encode transcription factors involved in developmental regulation. Understanding the mechanism underlying this association will provide insight into the genetics of breast tissue composition.

  8. Affinity proteomic profiling of plasma for proteins associated to area-based mammographic breast density.

    Science.gov (United States)

    Byström, Sanna; Eklund, Martin; Hong, Mun-Gwan; Fredolini, Claudia; Eriksson, Mikael; Czene, Kamila; Hall, Per; Schwenk, Jochen M; Gabrielson, Marike

    2018-02-14

    Mammographic breast density is one of the strongest risk factors for breast cancer, but molecular understanding of how breast density relates to cancer risk is less complete. Studies of proteins in blood plasma, possibly associated with mammographic density, are well-suited as these allow large-scale analyses and might shed light on the association between breast cancer and breast density. Plasma samples from 1329 women in the Swedish KARMA project, without prior history of breast cancer, were profiled with antibody suspension bead array (SBA) assays. Two sample sets comprising 729 and 600 women were screened by two different SBAs targeting a total number of 357 proteins. Protein targets were selected through searching the literature, for either being related to breast cancer or for being linked to the extracellular matrix. Association between proteins and absolute area-based breast density (AD) was assessed by quantile regression, adjusting for age and body mass index (BMI). Plasma profiling revealed linear association between 20 proteins and AD, concordant in the two sets of samples (p density and processes of tissue homeostasis, DNA repair, cancer development and/or progression in breast cancer. Further validation and follow-up studies of the shortlisted protein candidates in independent cohorts will be needed to infer their role in breast density and its progression in premenopausal and postmenopausal women.

  9. Mammographic breast density in recent and longer-standing ethiopian immigrants to israel.

    Science.gov (United States)

    Sklair-Levy, Miri; Segev, Anat; Sella, Tamar; Calderon-Margalit, Ronit; Zippel, Douglas

    2018-04-23

    High breast density is associated with an increased risk of breast cancer development. Little is known concerning ethnic variations in breast density and its relevant contributing factors. We aimed to study breast density among Ethiopian immigrants to Israel in comparison with Israeli-born women and to determine any effect on breast density of the length of residency in the immigrant population. Mammographic breast density using the BI-RADS system was estimated and compared between 77 women of Ethiopian origin who live in Israel and 177 Israeli-born controls. Logistic regression analysis was performed to estimate the odds ratios (OR) for high density (BI-RADS score ≥ 3) vs low density (BI-RADS score density compared with Israeli-born women. Adjustments for various cofounders did not affect the results. Time since immigration to Israel seemed to modify the relationship, with a stronger association for women who immigrated within 2 years prior to mammography (OR:0.07, 95% CI: 0.03-0.17) as opposed to women with a longer residency stay in Israel (OR:0.23, 95% CI:0.10-0.50). Adjustments of various confounders did not alter these findings. Breast density in Ethiopian immigrants to Israel is significantly lower than that of Israeli-born controls. Our study suggests a positive association between time since immigration and breast density. Future studies are required to define the possible effects of dietary change on mammographic density following immigration. © 2018 Wiley Periodicals, Inc.

  10. Mammographic Screening of Women Attending a Reference Service Center in Southern Brazil.

    Science.gov (United States)

    Romeiro Lopes, Tiara Cristina; Franca Gravena, Angela Andreia; Demitto, Marcela de Oliveira; Brischiliari, Sheila Cristina Rocha; Borghesan, Deise Helena Pelloso; Dell Agnolo, Catia Millene; Carvalho, Maria Dalva de Barros; Pelloso, Sandra Marisa

    2016-01-01

    To investigate the prevalence of and factors associated with performance of annual mammography by women above 40 years of age. This cross-sectional retrospective study was conducted at an oncology reference service in Southern Brazil from October 2013 to October 2014 with 525 women aged 40 years or older. The prevalence of annual mammography was 54.1%; annual mammographic screening was performed for women without private medical insurance, who were under hormone replacement therapy and who had used contraception in the past. An association was found between non-performance of breast clinical and self-examination and non-performance of mammographic screening. Use of mammography for breast cancer screening in the public health care setting proved to be accessible; nevertheless, the proportion of screened women was low, and they exhibited poor adherence to the basic measures of care recommended for breast assessment. Thus, control of breast cancer requires implementing actions targeting the population most vulnerable to non-adherence to screening in addition to continuously monitoring and assessing that population to reduce the prevalence of this disease.

  11. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  12. The significance of circumscribed malignant mammographic masses in the surveillance of BRCA 1/2 gene mutation carriers

    International Nuclear Information System (INIS)

    Kaas, R.; Kroger, R.; Besnard, A.P.E.; Koops, W.; Pameijer, F.A.; Prevoo, W.; Loo, C.E.; Muller, S.H.; Hendriks, J.H.C.L.

    2004-01-01

    Breast cancers in gene mutation carriers may escape mammographic detection because of rapid growth and tumor expansion. Therefore, they may mimic benign lesions on the mammogram. Twenty-nine BRCA 1/2 mutation carriers under surveillance developed 31 breast cancers between 1994 and 2001 at a mean age of 44.2 years. Controls were 63 women with 67 breast cancers in the same period at a mean age of 53.8 years, also under surveillance because of a life time risk of at least 15%. In 26% of the carriers vs. 48% of the controls, mammography was the method that first suspected a malignancy. Seven radiologists performed a retrospective review of the original mammograms to establish technical assessment, with special attention for circumscribed lesions and estimated probability of malignancy. In the mutation carriers seven (23%) circumscribed non-calcified mammographic masses were found and three in the controls (4.5%) P=0.01. These masses were proven to be malignant. In both groups around 70% of these fast-growing circumscribed lesions were detected by the patients. The masses were situated in breasts with a good interpretable breast pattern. BRCA 1/2 mutation carriers had a significantly higher percentage of circumscribed non-calcified mammographic masses that proved to be malignant. These mammographic lesions in women at high risk should be described as at least Birads 0 and worked-up with ultrasound and needle biopsy. (orig.)

  13. Mammographic density changes following discontinuation of tamoxifen in premenopausal women with oestrogen receptor-positive breast cancer.

    Science.gov (United States)

    Kim, Won Hwa; Cho, Nariya; Kim, Young-Seon; Yi, Ann

    2018-04-06

    To evaluate the changes in mammographic density after tamoxifen discontinuation in premenopausal women with oestrogen receptor-positive breast cancers and the underlying factors METHODS: A total of 213 consecutive premenopausal women with breast cancer who received tamoxifen treatment after curative surgery and underwent three mammograms (baseline, after tamoxifen treatment, after tamoxifen discontinuation) were included. Changes in mammographic density after tamoxifen discontinuation were assessed qualitatively (decrease, no change, or increase) by two readers and measured quantitatively by semi-automated software. The association between % density change and clinicopathological factors was evaluated using univariate and multivariate regression analyses. After tamoxifen discontinuation, a mammographic density increase was observed in 31.9% (68/213, reader 1) to 22.1% (47/213, reader 2) by qualitative assessment, with a mean density increase of 1.8% by quantitative assessment compared to density before tamoxifen discontinuation. In multivariate analysis, younger age (≤ 39 years) and greater % density decline after tamoxifen treatment (≥ 17.0%) were independent factors associated with density change after tamoxifen discontinuation (p density change with a mean density increase of 1.8%, which was associated with younger age and greater density change after tamoxifen treatment. • Increased mammographic density after tamoxifen discontinuation can occur in premenopausal women. • Mean density increase after tamoxifen discontinuation was 1.8%. • Density increase is associated with age and density decrease after tamoxifen.

  14. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  15. Mammographic Features of Local Recurrence after Conservative Surgery and Radiation Therapy: Comparison with that of the Primary Tumor

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, I.; Oktay, A.

    2007-01-01

    Purpose: To compare the mammographic features of recurrent breast cancer with those of the primary tumor and to determine whether certain mammographic features are associated with a higher risk of local recurrence after breast-conserving therapy. Material and Methods: A retrospective review of mammograms of 421 patients who were treated with conservative surgery and radiotherapy revealed 41 recurrent tumors. Mammographic findings, location, and histopathologic characteristics were retrospectively compared between primary and recurrent tumors. Results: Recurrent tumors were similar in mammographic appearance to primary tumors in 27 (66%) cases. Of 27 primary tumors that occurred as masses without calcifications, 19 (70%) recurred as a mass, and of the six isolated calcifications, five (83%) recurred with calcifications. Ten (53%) of the 19 recurrent masses and five (100%) of the five recurrent calcifications had morphologic features that were similar to those of the primary tumor. Ninety-two percent (11/12) of the recurrences containing microcalcifications (isolated or associated with a mass) had microcalcifications in their primary tumor. Of 27 masses that recurred, the morphology of the primary tumor was obscured in 13 (48%), ill defined in 10 (37%), and spiculated in four (15%) of the masses. Seventy-six percent (31/41) of recurrences were within the lumpectomy quadrant. In 25 (61%) cases, the histologic findings from the primary tumor and the recurrence were identical. Conclusion: The majority of recurrent tumors appear to be mammographically similar to primary tumors. Therefore, it is important to review preoperative mammograms during follow-up of these patients. Although the study population is small, it was noted that mass with spiculated contour is associated with a lower risk for local recurrence

  16. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    Science.gov (United States)

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Diagnostic imaging of lobular carcinoma of the breast. Mammographic, US and MR findings

    International Nuclear Information System (INIS)

    Bazzocchi, M.; Facecchia, I.; Zuiani, C.; Smania, S.; Puglisi, F.; Di Loreto, C.

    2000-01-01

    Purpose of this article is to evaluate the most frequent mammographic, US and MR findings of invasive lobular carcinoma and the role of MRI in defining multifocality and/or multi centricity of this tumor histotype. 45 lobular carcinomas in 39 patients were studied and selected from 421 breast cancers. Core biopsy with a 14G needle was performed in 39 cases, under US guidance in 36/39 and under mammographic guidance in 3/39 cases. Surgical biopsy was performed in 2 cases and the diagnosis could be made only after mastectomy in 5 cases. All patients were examined with mammography and US and (10-13 MHz) and 8 also with MRI. 28/46 palpable lesions (60.9%). Core biopsy correctly diagnosed 38/39 lesions (97.4%). The most frequent mammographic findings was that of a nodular opacity without microcalcifications (34.8%), followed by a mass with spiculate d borders (30.4%). Microcalcifications were seen in one case only (2.2%). Mammography detected no abnormalities in 15.2% of cases, but US showed a lesion in 2 of these cases. The most frequent US pattern was that of a hypoechoic lesion (43.5%), followed by posterior US beam attenuation. No US signs of abnormality were seen 15.2%. MRI correctly detected 13 lesions. Contrast enhancement was greater than 70% at one minute in 10 cases and greater than 40% in one case; two lesions exhibited atypical slow contrast enhancement, peaking at 5 minutes. MRI detected 5 lesions missed both mammography and US and showed multifocal (3 and 2) lesions where the other techniques had detected one lesion only. At mammography and US invasive lobular carcinoma exhibits no different features than ductal carcinoma but is difficult to identify especially in its early stages. US is a useful tool especially to characterize mammography-detected lesions but in the experience it also demonstrated 2 lesions missed at mammography. MRI is a precious examination to define the multifocal, multi centric or bilateral character of invasive lobular carcinoma

  18. Mammographic density and risk of breast cancer by tumor characteristics: a case-control study.

    Science.gov (United States)

    Krishnan, Kavitha; Baglietto, Laura; Stone, Jennifer; McLean, Catriona; Southey, Melissa C; English, Dallas R; Giles, Graham G; Hopper, John L

    2017-12-16

    In a previous paper, we had assumed that the risk of screen-detected breast cancer mostly reflects inherent risk, and the risk of whether a breast cancer is interval versus screen-detected mostly reflects risk of masking. We found that inherent risk was predicted by body mass index (BMI) and dense area (DA) or percent dense area (PDA), but not by non-dense area (NDA). Masking, however, was best predicted by PDA but not BMI. In this study, we aimed to investigate if these associations vary by tumor characteristics and mode of detection. We conducted a case-control study nested within the Melbourne Collaborative Cohort Study of 244 screen-detected cases matched to 700 controls and 148 interval cases matched to 446 controls. DA, NDA and PDA were measured using the Cumulus software. Tumor characteristics included size, grade, lymph node involvement, and ER, PR, and HER2 status. Conditional and unconditional logistic regression were applied as appropriate to estimate the Odds per Adjusted Standard Deviation (OPERA) adjusted for age and BMI, allowing the association with BMI to be a function of age at diagnosis. For screen-detected cancer, both DA and PDA were associated to an increased risk of tumors of large size (OPERA ~ 1.6) and positive lymph node involvement (OPERA ~ 1.8); no association was observed for BMI and NDA. For risk of interval versus screen-detected breast cancer, the association with risk for any of the three mammographic measures did not vary by tumor characteristics; an association was observed for BMI for positive lymph nodes (OPERA ~ 0.6). No associations were observed for tumor grade and ER, PR and HER2 status of tumor. Both DA and PDA were predictors of inherent risk of larger breast tumors and positive nodal status, whereas for each of the three mammographic density measures the association with risk of masking did not vary by tumor characteristics. This might raise the hypothesis that the risk of breast tumours with poorer prognosis

  19. Increased COX-2 expression in epithelial and stromal cells of high mammographic density tissues and in a xenograft model of mammographic density.

    Science.gov (United States)

    Chew, G L; Huo, C W; Huang, D; Hill, P; Cawson, J; Frazer, H; Hopper, J L; Haviv, I; Henderson, M A; Britt, K; Thompson, E W

    2015-08-01

    Mammographic density (MD) adjusted for age and body mass index is one of the strongest known risk factors for breast cancer. Given the high attributable risk of MD for breast cancer, chemoprevention with a safe and available agent that reduces MD and breast cancer risk would be beneficial. Cox-2 has been implicated in MD-related breast cancer risk, and was increased in stromal cells in high MD tissues in one study. Our study assessed differential Cox-2 expression in epithelial and stromal cells in paired samples of high and low MD human breast tissue, and in a validated xenograft biochamber model of MD. We also examined the effects of endocrine treatment upon Cox-2 expression in high and low MD tissues in the MD xenograft model. Paired high and low MD human breast tissue samples were immunostained for Cox-2, then assessed for differential expression and staining intensity in epithelial and stromal cells. High and low MD human breast tissues were separately maintained in biochambers in mice treated with Tamoxifen, oestrogen or placebo implants, then assessed for percentage Cox-2 staining in epithelial and stromal cells. Percentage Cox-2 staining was greater for both epithelial (p = 0.01) and stromal cells (p tissues. In high MD biochamber tissues, percentage Cox-2 staining was greater in stromal cells of oestrogen-treated versus placebo-treated tissues (p = 0.05).

  20. Mammographic detection of breast arterial calcification as an independent predictor of coronary atherosclerotic disease in a single ethnic cohort of African American women

    NARCIS (Netherlands)

    Newallo, Domnique; Meinel, Felix G.; Schoepf, U. Joseph; Baumann, Stefan; De Cecco, Carlo N.; Leddy, Rebecca J.; Vliegenthart, Rozemarijn; Moellmann, Helge; Hamm, Christian W.; Morris, Pamela B.; Renker, Matthias

    Objective: Accumulating data on predominantly Caucasian women suggests an association between breast arterial calcification (BAC) and coronary artery disease (CAD). We sought to comprehensively examine the correlation between mammographic BAC and CAD endpoints detected by cardiac computed tomography

  1. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  2. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  3. Diabetes, diabetes treatment, and mammographic density in Danish Diet, Cancer, and Health cohort

    DEFF Research Database (Denmark)

    Buschard, Karsten; Thomassen, Katrin; Lynge, Elsebeth

    2017-01-01

    PURPOSE: We examined whether diabetes and diabetes treatment are associated with MD in a cohort study of Danish women above age of 50 years. METHODS: Study cohort consisted of 5,644 women (4,500 postmenopausal) who participated in the Danish Diet, Cancer, and Health cohort (1993......-1997) and subsequently attended mammographic screening in Copenhagen (1993-2001). We used MD assessed at the first screening after the cohort entry, defined as mixed/dense or fatty. Diabetes diagnoses and diabetes treatments (diet, insulin, or oral antidiabetic agents) were self-reported at the time of recruitment (1993.......61; 0.40-0.92). Similar inverse associations were observed for 44 women who controlled diabetes by diet only and did not receive any medication (0.56; 0.27-1.14), and 62 who took oral antidiabetic agents only for diabetes (0.59; 0.32-1.09), while women taking insulin had increased odds of mixed...

  4. Mammographic manifestations of mammary hamartoma (with an analysis of 10 cases)

    International Nuclear Information System (INIS)

    Yu Cheng; Luo Zebin; Chen Yun; Lin Wenmiao; Diao Shenglin

    2006-01-01

    Objective: To analyze the mammographic characteristics and the pathological basis of mammary hamartoma. Methods: The mammogram of 10 cases of mammary hamartoma proved by pathology were retrospectively analyzed. The patients aged from 25 to 56 years with an average age of (40.1 ± 5.4 years ). Results: According to the fat/parenchyma ratio, the mammgraphic manifestations of mammary hamartoma were divided into three types. 2 highly radiolucent lesions were classified as fat type, 2 lesions with high density were classified as dense type and the rest 6 lesions were the mixed type composed of adipose and glandular tissue. The mixed type was the most distinctive, while the dense or rat type was easy to be misdiagnosed. Accurate diagnosis was made in 6 cases out of, and the overall diagnostic accuracy was 60%. Conclusion: Mammography is the choice of diagnosis, and an accurate diagnosis will help surgical planning. (authors)

  5. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  6. Evaluation of the observation of breast glands condition in mammographic early detection programme

    International Nuclear Information System (INIS)

    Kleszczewska, J.; Zomer-Drozda, J.; Tarlowska, L.; Romejko, M.

    1993-01-01

    The results of mammography tests were evaluated for 542 female employees of higher schools during an observation continued over 1 to 7.5 years, and they were compared with the results of the first test. Among 22 cancers detected and confirmed by macroscopic examination, mammography result turned out to be false negative in 2 cases. A positive error occurred in 7 cases. Cancer developed during observation in 8 women, that is, in 4 women from the group of 365 who earlier had correct mammography results (1.1%) and another 4 in the group of 154 women originally showing benign changes in their breast glands (2.6%). This work confirms the importance of regular checkups in the mammographic early detection programme. (author)

  7. Using Five Machine Learning for Breast Cancer Biopsy Predictions Based on Mammographic Diagnosis

    OpenAIRE

    Oyewola, David; Hakimi, Danladi; Adeboye, Kayode; Shehu, Musa Danjuma

    2017-01-01

    Breast cancer is one of thecauses of female death in the world. Mammography  is commonly  used for  distinguishing  malignant tumors  from benign  ones. In this research,  a mammographic  diagnostic method  is  presented for breast  cancer  biopsy outcome  predictions  using  fivemachine learning which includes: Logistic Regression(LR), Linear DiscriminantAnalysis(LDA), Quadratic Discriminant Analysis(QDA), Random Forest(RF) andSupport  Vector Machine(SVM)  classification.  The testing result...

  8. Mammographic and sonographic findings of steatocystoma multiplex presenting as breast lumps.

    Science.gov (United States)

    Wan, John Mun Chin; Wong, Jill Su Lin; Tee, Shang-Ian

    2012-12-01

    Steatocystoma multiplex (SM) is an uncommon cutaneous disorder characterised by multiple intradermal cysts distributed over the trunk and proximal extremities. This condition affects both genders and is often inherited as an autosomal dominant trait, although sporadic cases have been described. This report describes the mammographic and sonographic features of the cysts, which presented as breast lumps, for evaluation. The cysts appeared as numerous well-circumscribed, radiolucent nodules with thin radiodense rims on mammography. On sonography, the cysts could be hypoechoic, isoechoic or demonstrate mixed echoes containing debris-fluid levels, depending on the amount of clear oily liquid and keratinous material. SM can be diagnosed based on a clinical setting of multiple asymptomatic small intradermal nodules over the trunk and proximal extremities, positive family history and imaging findings.

  9. Mammographic Imaging Studies Using the Monte Carlo Image Simulation-Differential Sampling (MCMIS-DS) Code

    International Nuclear Information System (INIS)

    Kuruvilla Verghese

    2002-01-01

    This report summarizes the highlights of the research performed under the 1-year NEER grant from the Department of Energy. The primary goal of this study was to investigate the effects of certain design changes in the Fisher Senoscan mammography system and in the degree of breast compression on the discernability of microcalcifications in calcification clusters often observed in mammograms with tumor lesions. The most important design change that one can contemplate in a digital mammography system to improve resolution of calcifications is the reduction of pixel dimensions of the digital detector. Breast compression is painful to the patient and is though to be a deterrent to women to get routine mammographic screening. Calcification clusters often serve as markers (indicators ) of breast cancer

  10. Occult inflammatory breast cancer: review of clinical, mammographic, US and pathologic signs

    International Nuclear Information System (INIS)

    Cumo, Francesca; Gaioni, Maria Berenice; Bonetti, Franco; Manfrin, Erminia; Remo, Andrea; Pattaro, Christian; Policlinico G.B. Rossi, Verona

    2005-01-01

    Purpose: To examine the clinical, radiologic and pathologic findings of occult inflammatory breast cancer (OIBC) in order to identify features useful for diagnosis. Materials and methods: We retrospectively reviewed the records of 19 women with OIBC observed at our Department between 1992 and 2001. We analysed the clinical history, mammographic, ultrasonographic, and pathologic findings and investigated overall survival (OS), prognostic variables and radio-pathologic correlations. Results: The most common mammographic findings were: diffusely density (52.63%), trabecular thickening (42.1%), mass (36.84%). The most common US findings were axillary lymphadenopathy (68,75%), skin thickening (43.75%) and mass (56.25%). At least one inflammatory sign was found in 14 women (74%) at mammography (subcutaneous thickening, trabecular thickening, diffuse increase of density) or at US (subcutaneous thickening, diffuse increase in echogenicity due to oedema, lymph vessel dilatation). Estrogen receptors (ER) were present in 63.2% and Progesterone receptors (PgR) in 36.8%. Significant prognostic variables were ER and Ki 67. Conclusions: The typical radiological pattern of clinical inflammatory breast carcinoma is less frequently present in OIBC; nevertheless the radiologist must pay attention because frequently OIBC presents just one radiological sign and this should be enough for a diagnostic suspicion. Moreover, the absence of clinical and radiological inflammatory signs does not exclude inflammatory breasts cancer because OIBC can manifest at imaging as a mass or isolated calcification. ER and PgR are positive in a high percentage of patients and confirm that OIBC has a better prognosis that clinical inflammatory breast cancer [it

  11. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  12. Comparison of mammographic and sonographic findings in typical and atypical medullary carcinomas of the breast

    International Nuclear Information System (INIS)

    Yilmaz, E.; Lebe, B.; Balci, P.; Sal, S.; Canda, T.

    2002-01-01

    AIM: The aim of this study was to describe the contribution of mammographic and sonographic findings to the discrimination of typical and atypical histopathologic groups of medullary carcinomas of the breast. MATERIALS AND METHODS: Imaging findings were retrospectively assessed in 33 women with medullary carcinomas (15 typical medullary carcinomas and 18 atypical medullary carcinomas) identified during pre-operative mammography. Twenty-nine of these women also had ultrasound and these findings were reviewed. RESULTS: Mammography showed a well circumscribed mass in 10 of the 15 (67%) typical medullary carcinomas and in four of the 17 (24%) atypical medullary carcinomas (P < 0.02). One small tumour in a woman with atypical medullary carcinoma was missed on mammography and was shown only on sonography. Sonographically, an irregular margin surrounding the whole mass or part of it was seen in three out of 14 (21%) patients with typical medullary carcinoma and in nine out of 15 (60%) patients with atypical medullary carcinomas (P < 0.05). Posterior acoustic shadowing was more often observed in the typical medullary carcinoma group than in atypical medullary carcinoma and the difference was found to be statistically significant (P < 0.05). None of the other mammographic and sonographic findings were sufficiently characteristic to allow for a differentiation between two groups. CONCLUSION: When typical medullary carcinomas were compared with atypical medullary carcinomas according to imaging features, they tended to be well circumscribed masses on both mammography and sonography, and a posterior acoustic shadow was not found on sonography. However, the imaging findings in these two subgroups often resembled each other and histopathology will always be required to confirm the diagnosis. Yilmaz, E. et al. (2002)

  13. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions

  14. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions.

  15. Construction of mammographic examination process ontology using bottom-up hierarchical task analysis.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Jiang, Guoqian; Tsuji, Shintarou; Fukuda, Akihisa; Nishimoto, Naoki; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2018-03-01

    Describing complex mammography examination processes is important for improving the quality of mammograms. It is often difficult for experienced radiologic technologists to explain the process because their techniques depend on their experience and intuition. In our previous study, we analyzed the process using a new bottom-up hierarchical task analysis and identified key components of the process. Leveraging the results of the previous study, the purpose of this study was to construct a mammographic examination process ontology to formally describe the relationships between the process and image evaluation criteria to improve the quality of mammograms. First, we identified and created root classes: task, plan, and clinical image evaluation (CIE). Second, we described an "is-a" relation referring to the result of the previous study and the structure of the CIE. Third, the procedural steps in the ontology were described using the new properties: "isPerformedBefore," "isPerformedAfter," and "isPerformedAfterIfNecessary." Finally, the relationships between tasks and CIEs were described using the "isAffectedBy" property to represent the influence of the process on image quality. In total, there were 219 classes in the ontology. By introducing new properties related to the process flow, a sophisticated mammography examination process could be visualized. In relationships between tasks and CIEs, it became clear that the tasks affecting the evaluation criteria related to positioning were greater in number than those for image quality. We developed a mammographic examination process ontology that makes knowledge explicit for a comprehensive mammography process. Our research will support education and help promote knowledge sharing about mammography examination expertise.

  16. Comparison of mammographic and sonographic findings in typical and atypical medullary carcinomas of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, E.; Lebe, B.; Balci, P.; Sal, S.; Canda, T

    2002-07-01

    AIM: The aim of this study was to describe the contribution of mammographic and sonographic findings to the discrimination of typical and atypical histopathologic groups of medullary carcinomas of the breast. MATERIALS AND METHODS: Imaging findings were retrospectively assessed in 33 women with medullary carcinomas (15 typical medullary carcinomas and 18 atypical medullary carcinomas) identified during pre-operative mammography. Twenty-nine of these women also had ultrasound and these findings were reviewed. RESULTS: Mammography showed a well circumscribed mass in 10 of the 15 (67%) typical medullary carcinomas and in four of the 17 (24%) atypical medullary carcinomas (P < 0.02). One small tumour in a woman with atypical medullary carcinoma was missed on mammography and was shown only on sonography. Sonographically, an irregular margin surrounding the whole mass or part of it was seen in three out of 14 (21%) patients with typical medullary carcinoma and in nine out of 15 (60%) patients with atypical medullary carcinomas (P < 0.05). Posterior acoustic shadowing was more often observed in the typical medullary carcinoma group than in atypical medullary carcinoma and the difference was found to be statistically significant (P < 0.05). None of the other mammographic and sonographic findings were sufficiently characteristic to allow for a differentiation between two groups. CONCLUSION: When typical medullary carcinomas were compared with atypical medullary carcinomas according to imaging features, they tended to be well circumscribed masses on both mammography and sonography, and a posterior acoustic shadow was not found on sonography. However, the imaging findings in these two subgroups often resembled each other and histopathology will always be required to confirm the diagnosis. Yilmaz, E. et al. (2002)

  17. Identification of two novel mammographic density loci at 6Q25.1.

    Science.gov (United States)

    Brand, Judith S; Li, Jingmei; Humphreys, Keith; Karlsson, Robert; Eriksson, Mikael; Ivansson, Emma; Hall, Per; Czene, Kamila

    2015-06-03

    Mammographic density (MD) is a strong heritable and intermediate phenotype for breast cancer, but much of its genetic variation remains unexplained. We performed a large-scale genetic association study including 8,419 women of European ancestry to identify MD loci. Participants of three Swedish studies were genotyped on a custom Illumina iSelect genotyping array and percent and absolute mammographic density were ascertained using semiautomated and fully automated methods from film and digital mammograms. Linear regression analysis was used to test for SNP-MD associations, adjusting for age, body mass index, menopausal status and six principal components. Meta-analyses were performed by combining P values taking sample size, study-specific inflation factor and direction of effect into account. Genome-wide significant associations were observed for two previously identified loci: ZNF365 (rs10995194, P = 2.3 × 10(-8) for percent MD and P = 8.7 × 10(-9) for absolute MD) and AREG (rs10034692, P = 6.7 × 10(-9) for absolute MD). In addition, we found evidence of association for two variants at 6q25.1, both of which are known breast cancer susceptibility loci: rs9485370 in the TAB2 gene (P = 4.8 × 10(-9) for percent MD and P = 2.5 × 10(-8) for absolute MD) and rs60705924 in the CCDC170/ESR1 region (P = 2.2 × 10(-8) for absolute MD). Both regions have been implicated in estrogen receptor signaling with TAB2 being a potential regulator of tamoxifen response. We identified two novel MD loci at 6q25.1. These findings underscore the importance of 6q25.1 as a susceptibility region and provide more insight into the mechanisms through which MD influences breast cancer risk.

  18. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  19. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  20. [Modeling of a three-dimensional structure of cytochrome P-450 1A2 and search for its new ligands].

    Science.gov (United States)

    Belkina, N V; Skvortsov, V S; Ivanov, A S; Archakov, A I

    1998-01-01

    The substances inhibiting cytochrome P450 1A2 (CYP1A2) represent a perspective class of new drugs, which application in clinical practice can become the important part in preventive maintenance in oncology. The present work is devoted to computer modelling of 3-D structure of CYP1A2 and searching of new inhibitors by database mining. The modelling of CYP1A2 was done based on homology with 4 bacterial cytochromes P450 with known 3-D structure. For optimization of CYP1A2 active site structure the models of its complexes with characteristic substrates (caffeine and 7-ethoxyresorufin) were designed. These complexes were optimized by molecular dynamics simulation in water. The models of 24 complexes of CYP1A2 with known ligands with known Kd were designed by means of DockSearch and LeapFrog programs. 3D-QSAR model with good predictive force was created based on these complexes. On a final stage the search of knew CYP1A2 ligands in testing database (more than 23.000 substances from database Maybridge and 112 known CYP1A2 ligands from database Metabolite, MDL) was executed. 680 potential ligands of CYP1A2 with Kd values, comparable with known ones were obtained. This number has included 73 compounds from 112 known ligands, introduced in tested database as the internal control.

  1. Results of conservative surgery and radiation for mammographically detected ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Fowble, B.; Hanlon, A.L.; Fein, D.A.; Hoffman, J.P.; Sigurdson, E.R.; Patchefsky, A.; Kessler, H.

    1996-01-01

    Purpose: The role of conservative surgery and radiation for mammographically detected DCIS is controversial. In particular, there is a paucity of data for outcome with radiation in a group of patients comparable to those treated with local excision and surveillance (mammographically detected DCIS ≤2.5 cm, negative resection margins, negative post-biopsy mammogram). The purpose of this study is to report long term outcome of conservative surgery and radiation for mammographically detected DCIS with emphasis on the results in patients (pts.) considered candidates for excision alone. Materials and Methods: From 1983 to 1992, 110 women with mammographically detected DCIS (calcifications 72%, mass ± calcifications 27%) and no prior history of breast cancer underwent needle localization biopsy followed by radiation. The median age of the patient population was 56 yrs. (range 37-81). The median followup was 5.3 yrs. (range .5-12). Re-excision was performed in 55%. Final margins of resection were negative in 62%, positive 7%, close 11%, and unknown 20%. Axillary dissection was performed in 31 pts. and all had negative nodes. 31% had a positive family history of breast cancer (1 affected relative-25 pts., two-7 pts., three-2 pts.). The most common predominant histologic subtype was comedo (54%) followed by cribriform (22%). The median pathologic tumor size was 8 mm (range 2 mm to 5 cm). A post-biopsy mammogram prior to radiation was performed in 46% of the patients. Radiation consisted of treatment to the entire breast (median 5000 cGy) with a boost to the primary site (97%) of an additional 1000 cGy. The median total dose to the primary site was 6040 cGy (range 5000 to 6660). Results: Three patients developed a recurrence in the treated breast at 52, 106, and 107 months. All 3 recurrences were invasive ductal cancers and all were treated with mastectomy. The location of the recurrence was in the same quadrant as the primary in 1 pt. and in a separate quadrant in 2 pts

  2. Inter-observer agreement according to three methods of evaluating mammographic density and parenchymal pattern in a case control study

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Nielsen, Mads

    2015-01-01

    , Tabár's PIV and PV and the upper two quartiles (within density range) of PMD. The relative risk of breast cancer was estimated using logistic regression to calculate odds ratios (ORs) adjusted for age, which were compared between the two readers. RESULTS: Substantial inter-observer agreement was seen......, respectively. Inter-reader variability showed different impact on the relative risk of breast cancer estimated by the two readers on a multiple-category scale, however, not on a high/low-risk scale. Tabár's pattern IV demonstrated the highest ORs of all density patterns investigated. CONCLUSIONS: Our study......BACKGROUND: Mammographic breast density and parenchymal patterns are well-established risk factors for breast cancer. We aimed to report inter-observer agreement on three different subjective ways of assessing mammographic density and parenchymal pattern, and secondarily to examine what potential...

  3. Impact of digitalization of mammographic units on average glandular doses in the Flemish Breast Cancer Screening Program

    OpenAIRE

    De Hauwere, An; Thierens, Hubert

    2012-01-01

    The impact of digitalization on the average glandular doses in 49 mammographic units participating in the Flemish Breast Cancer Screening Program was studied. Screen-film was changed to direct digital radiography and computed radiography in 25 and 24 departments respectively. Average glandular doses were calculated before and after digitalization for different PMMA-phantom thicknesses and for groups of 50 successive patients. For the transition from screen-film to computed radiography both ph...

  4. Association between mammographic density and pregnancies relative to age and BMI: a breast cancer case-only analysis.

    Science.gov (United States)

    Hack, Carolin C; Emons, Julius; Jud, Sebastian M; Heusinger, Katharina; Adler, Werner; Gass, Paul; Haeberle, Lothar; Heindl, Felix; Hein, Alexander; Schulz-Wendtland, Rüdiger; Uder, Michael; Hartmann, Arndt; Beckmann, Matthias W; Fasching, Peter A; Pöhls, Uwe G

    2017-12-01

    Percentage mammographic density (PMD) is a major risk factor for breast cancer (BC). It is strongly associated with body mass index (BMI) and age, which are themselves risk factors for breast cancer. This analysis investigated the association between the number of full-term pregnancies and PMD in different subgroups relative to age and BMI. Patients were identified in the breast cancer database of the University Breast Center for Franconia. A total of 2410 patients were identified, for whom information on parity, age, and BMI, and a mammogram from the time of first diagnosis were available for assessing PMD. Linear regression analyses were conducted to investigate the influence on PMD of the number of full-term pregnancies (FTPs), age, BMI, and interaction terms between them. As in previous studies, age, number of FTPs, and BMI were found to be associated with PMD in the expected direction. However, including the respective interaction terms improved the prediction of PMD even further. Specifically, the association between PMD and the number of FTPs differed in young patients under the age of 45 (mean decrease of 0.37 PMD units per pregnancy) from the association in older age groups (mean decrease between 2.29 and 2.39 PMD units). BMI did not alter the association between PMD and the number of FTPs. The effect of pregnancies on mammographic density does not appear to become apparent before the age of menopause. The mechanism that drives the effect of pregnancies on mammographic density appears to be counter-regulated by other influences on mammographic density in younger patients.

  5. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  6. Tumor characteristics and family history in relation to mammographic density and breast cancer: The French E3N cohort.

    Science.gov (United States)

    Maskarinec, Gertraud; Dartois, Laureen; Delaloge, Suzette; Hopper, John; Clavel-Chapelon, Françoise; Baglietto, Laura

    2017-08-01

    Mammographic density is a known heritable risk factor for breast cancer, but reports how tumor characteristics and family history may modify this association are inconsistent. Dense and total breast areas were assessed using Cumulus™ from pre-diagnostic mammograms for 820 invasive breast cancer cases and 820 matched controls nested within the French E3N cohort study. To allow comparisons across models, percent mammographic density (PMD) was standardized to the distribution of the controls. Odds ratios (OR) and 95% confidence intervals (CI) of breast cancer risk for mammographic density were estimated by conditional logistic regression while adjusting for age and body mass index. Heterogeneity according to tumor characteristic and family history was assessed using stratified analyses. Overall, the OR per 1 SD for PMD was 1.50 (95% CI, 1.33-1.69). No evidence for significant heterogeneity by tumor size, lymph node status, grade, and hormone receptor status (estrogen, progesterone, and HER2) was detected. However, the association of PMD was stronger for women reporting a family history of breast cancer (OR 1SD =2.25; 95% CI, 1.67-3.04) than in women reporting none (OR 1SD =1.41; 95% CI, 1.24-1.60; p heterogeneity =0.002). Similarly, effect modification by FHBC was observed using categories of PMD (p heterogeneity =0.02) with respective ORs of 15.16 (95% CI, 4.23-54.28) vs. 3.14 (95% CI, 1.89-5.22) for ≥50% vs. breast cancer risk with a family history supports the hypothesis of shared genetic factors responsible for familial aggregation of breast cancer and the heritable component of mammographic density. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Double-blind randomized 12-month soy intervention had no effects on breast MRI fibroglandular tissue density or mammographic density

    Science.gov (United States)

    Wu, Anna H.; Spicer, Darcy; Garcia, Agustin; Tseng, Chiu-Chen; Hovanessian-Larsen, Linda; Sheth, Pulin; Martin, Sue Ellen; Hawes, Debra; Russell, Christy; McDonald, Heather; Tripathy, Debu; Su, Min-Ying; Ursin, Giske; Pike, Malcolm C.

    2015-01-01

    Soy supplementation by breast cancer patients remains controversial. No controlled intervention studies have investigated the effects of soy supplementation on mammographic density in breast cancer patients. We conducted a double-blind, randomized, placebo-controlled intervention study in previously treated breast cancer patients (n=66) and high-risk women (n=29). We obtained digital mammograms and breast magnetic resonance imaging (MRI) scans at baseline and after 12 months of daily soy (50 mg isoflavones per day) (n=46) or placebo (n=49) tablet supplementation. The total breast area (MA) and the area of mammographic density (MD) on the mammogram was measured using a validated computer-assisted method, and mammographic density percent (MD% = 100 × MD/MA) was determined. A well-tested computer algorithm was used to quantitatively measure the total breast volume (TBV) and fibroglandular tissue volume (FGV) on the breast MRI, and the FGV percent (FGV% = 100 × FGV/TBV) was calculated. On the basis of plasma soy isoflavone levels, compliance was excellent. Small decreases in MD% measured by the ratios of month 12 to baseline levels, were seen in the soy (0.95) and the placebo (0.87) groups; these changes did not differ between the treatments (P=0.38). Small decreases in FGV% were also found in both the soy (0.90) and the placebo (0.92) groups; these changes also did not differ between the treatments (P=0.48). Results were comparable in breast cancer patients and high-risk women. We found no evidence that soy supplementation would decrease mammographic density and that MRI might be more sensitive to changes in density than mammography. PMID:26276750

  8. Mammographic features and subsequent risk of breast cancer: a comparison of qualitative and quantitative evaluations in the Guernsey prospective studies.

    Science.gov (United States)

    Torres-Mejía, Gabriela; De Stavola, Bianca; Allen, Diane S; Pérez-Gavilán, Juan J; Ferreira, Jorge M; Fentiman, Ian S; Dos Santos Silva, Isabel

    2005-05-01

    Mammographic features are known to be associated with breast cancer but the magnitude of the effect differs markedly from study to study. Methods to assess mammographic features range from subjective qualitative classifications to computer-automated quantitative measures. We used data from the UK Guernsey prospective studies to examine the relative value of these methods in predicting breast cancer risk. In all, 3,211 women ages > or =35 years who had a mammogram taken in 1986 to 1989 were followed-up to the end of October 2003, with 111 developing breast cancer during this period. Mammograms were classified using the subjective qualitative Wolfe classification and several quantitative mammographic features measured using computer-based techniques. Breast cancer risk was positively associated with high-grade Wolfe classification, percent breast density and area of dense tissue, and negatively associated with area of lucent tissue, fractal dimension, and lacunarity. Inclusion of the quantitative measures in the same model identified area of dense tissue and lacunarity as the best predictors of breast cancer, with risk increasing by 59% [95% confidence interval (95% CI), 29-94%] per SD increase in total area of dense tissue but declining by 39% (95% CI, 53-22%) per SD increase in lacunarity, after adjusting for each other and for other confounders. Comparison of models that included both the qualitative Wolfe classification and these two quantitative measures to models that included either the qualitative or the two quantitative variables showed that they all made significant contributions to prediction of breast cancer risk. These findings indicate that breast cancer risk is affected not only by the amount of mammographic density but also by the degree of heterogeneity of the parenchymal pattern and, presumably, by other features captured by the Wolfe classification.

  9. Mammographic density and histopathologic characteristics of screen-detected tumors in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Moshina, Nataliia; Ursin, Giske; Hoff, Solveig Roth; Akslen, Lars A; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2015-01-01

    High mammographic density might mask breast tumors, resulting in delayed diagnosis or missed cancers. To investigate the association between mammographic density and histopathologic tumor characteristics (histologic type, size, grade, and lymph node status) among women screened in the Norwegian Breast Cancer Screening Program. Information about 1760 screen-detected ductal carcinoma in situ (DCIS) and 7366 invasive breast cancers diagnosed among women aged 50–69 years, 1996–2010, was analyzed. The screening mammograms were classified subjectively according to the amount of fibroglandular tissue into fatty, medium dense, and dense by breast radiologists. Chi-square test was used to compare the distribution of tumor characteristics by mammographic density. Odds ratio (OR) of tumor characteristics by density was estimated by means of logistic regression, adjusting for screening mode (screen-film and full-field digital mammography), and age. Mean and median tumor size of invasive breast cancers was 13.8 and 12 mm, respectively, for women with fatty breasts, and 16.2 and 14 mm for those with dense breasts. Lymph node positive tumors were identified among 20.6% of women with fatty breasts compared with 27.2% of those with dense breasts (P < 0.001). The proportion of DCIS was significantly lower for women with fatty (15.8%) compared with dense breasts (22.0%). Women with dense breasts had an increased risk of large (OR, 1.44; 95% CI, 1.18–1.73) and lymph node positive tumors (OR, 1.26; 95% CI, 1.05–1.51) compared with women with fatty and medium dense breasts. High mammographic density was positively associated with tumor size and lymph node positive tumors

  10. Radiologic-pathologic correlation of the mammographic findings retrospectively detected in inflammatory breast cancer. Usefulness in clinical practice

    International Nuclear Information System (INIS)

    Caumo, F.; Manfrin, E.; Bonetti, F.; Pinali, L.; Procacci, C.

    2002-01-01

    Background. The aim of this study was to describe the clinical, mammographical and pathological characteristics of inflammatory carcinoma. Patients and methods. Clinical, mammographical and histological sections of twenty-two women (age range 28-60 years) were reviewed. The examinations had been performed over a period of four years. Results. The clinical findings were: erythema, edema, thickening of the skin and breast heat in ten patients; palpable mass in nine patients; nipple discharge in one patient; absent in two patients. Pathological findings were: tumor emboli in the dermal lymphatics in eight patients; tumor emboli in the vessels in ten patients; tumor emboli both in the dermal lymphatics and in the vessels in four patients. The radiologic findings were: skin thickening, trabecular thickening and blurring of structure in ten patients (common presentation); mass in nine patients; malignant-type calcifications in two patients (uncommon presentation); absent in one patient. The follow-up examination (eighteen months) detected that only one patient with common presentation of inflammatory carcinoma had no local or systemic recurrence against eight patients with uncommon presentation. Conclusions. The clinical and mammographical aspects, which suggest the presence of an inflammatory carcinoma, occur only in 45.4% of the patients. The radiological aspect seems to correlate with the different prognosis of the tumour, resulting in a better prognosis in those with an uncommon aspect. (author)

  11. Genome-wide association study identifies multiple loci associated with both mammographic density and breast cancer risk

    Science.gov (United States)

    Lindström, Sara; Thompson, Deborah J.; Paterson, Andrew D.; Li, Jingmei; Gierach, Gretchen L.; Scott, Christopher; Stone, Jennifer; Douglas, Julie A.; dos-Santos-Silva, Isabel; Fernandez-Navarro, Pablo; Verghase, Jajini; Smith, Paula; Brown, Judith; Luben, Robert; Wareham, Nicholas J.; Loos, Ruth J.F.; Heit, John A.; Pankratz, V. Shane; Norman, Aaron; Goode, Ellen L.; Cunningham, Julie M.; deAndrade, Mariza; Vierkant, Robert A.; Czene, Kamila; Fasching, Peter A.; Baglietto, Laura; Southey, Melissa C.; Giles, Graham G.; Shah, Kaanan P.; Chan, Heang-Ping; Helvie, Mark A.; Beck, Andrew H.; Knoblauch, Nicholas W.; Hazra, Aditi; Hunter, David J.; Kraft, Peter; Pollan, Marina; Figueroa, Jonine D.; Couch, Fergus J.; Hopper, John L.; Hall, Per; Easton, Douglas F.; Boyd, Norman F.; Vachon, Celine M.; Tamimi, Rulla M.

    2015-01-01

    Mammographic density reflects the amount of stromal and epithelial tissues in relation to adipose tissue in the breast and is a strong risk factor for breast cancer. Here we report the results from meta-analysis of genome-wide association studies (GWAS) of three mammographic density phenotypes: dense area, non-dense area and percent density in up to 7,916 women in stage 1 and an additional 10,379 women in stage 2. We identify genome-wide significant (P<5×10−8) loci for dense area (AREG, ESR1, ZNF365, LSP1/TNNT3, IGF1, TMEM184B, SGSM3/MKL1), non-dense area (8p11.23) and percent density (PRDM6, 8p11.23, TMEM184B). Four of these regions are known breast cancer susceptibility loci, and four additional regions were found to be associated with breast cancer (P<0.05) in a large meta-analysis. These results provide further evidence of a shared genetic basis between mammographic density and breast cancer and illustrate the power of studying intermediate quantitative phenotypes to identify putative disease susceptibility loci. PMID:25342443

  12. False Negative Mammogram of Breast Cancer : Analysis of Mammographic and Sonographic Findings and Correlation with Clinical Findings

    International Nuclear Information System (INIS)

    Lee, Kil Jun; Lee, Ji Yeon; Han, Sung Nim; Jeong, Seong Ki; Tae, Seok; Shin, Kyoung Ja; Lee, Sang Chun

    1995-01-01

    Recent mammographic equipment have been of good quality and yielded high diagnostic accuracy for the detection of breast cancer. However, negative mammogram does not necessarily rule out breast cancer. Therefore were viewed cause of false negative mammography in confirmed breast cancer to improve diagnostic accuracy and for adequate clinical approach. We reviewed 19 cases of confirmed breast cancer, which showed false negative mammography with positive sonographic findings. Retrospective analysis was done by correlating the patient's age, sonographic finding and mass size, mammographic breast pattern and cause of false negative mammogram, and clinical symptoms. Among the 5 patients below 35 years in age, mass was not visible due to dense breast in 4 and due to small size in 1 case. In 14 patients over 35 years in age, 11 had normal mammographic findings, 4 had dense breast, and 7 had small sized mass. Remaining 3 cases showed asymmetric density in 2 and architecture distortion in 1 case. All showed mass lesion in sonography : ill defined malignant appearance in 14,well defined malignant appearance in 2, and well defined benign in 3 cases. Negative mammogram should be correlated with sonography in case of dense breast, below 35 years in age with palpable mass and under risk for breast cancer

  13. Mammographic Density Reduction as a Prognostic Marker for Postmenopausal Breast Cancer: Results Using a Joint Longitudinal-Survival Modeling Approach.

    Science.gov (United States)

    Andersson, Therese M-L; Crowther, Michael J; Czene, Kamila; Hall, Per; Humphreys, Keith

    2017-11-01

    Previous studies have linked reductions in mammographic density after a breast cancer diagnosis to an improved prognosis. These studies focused on short-term change, using a 2-stage process, treating estimated change as a fixed covariate in a survival model. We propose the use of a joint longitudinal-survival model. This enables us to model long-term trends in density while accounting for dropout as well as for measurement error. We studied the change in mammographic density after a breast cancer diagnosis and its association with prognosis (measured by cause-specific mortality), overall and with respect to hormone replacement therapy and tamoxifen treatment. We included 1,740 women aged 50-74 years, diagnosed with breast cancer in Sweden during 1993-1995, with follow-up until 2008. They had a total of 6,317 mammographic density measures available from the first 5 years of follow-up, including baseline measures. We found that the impact of the withdrawal of hormone replacement therapy on density reduction was larger than that of tamoxifen treatment. Unlike previous studies, we found that there was an association between density reduction and survival, both for tamoxifen-treated women and women who were not treated with tamoxifen. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  14. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect.

    Science.gov (United States)

    Napolitano, Mary E; Trueblood, Jon H; Hertel, Nolan E; David, George

    2002-09-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within +/-1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  15. Polymorphisms in genes involved in the estrogen pathway and mammographic density

    Directory of Open Access Journals (Sweden)

    Dumas Isabelle

    2010-11-01

    Full Text Available Abstract Background Single nucleotide polymorphisms (SNPs in genes involved in the estrogen pathway appear to be associated with breast cancer risk and possibly with mammographic density (MD, but little is known of these associations among premenopausal women. This study examines the association of 11 polymorphisms in five estrogen-related genes (estrogen receptors alpha and beta (ERα, ERβ, 17β-hydroxysteroid dehydrogenase 1 (HSD17B1, catechol-O-methyltransferase (COMT, cytochrome P450 1B1 (CYP1B1 with premenopausal MD. Effect modification of four estrogen-related factors (parity, age at menarche, hormonal derivatives use and body mass index (BMI on this relation is also assessed. Methods Polymorphisms were genotyped in 741 premenopausal Caucasian women whose MD was measured in absolute density (AD, cm2 and percent density using a computer-assisted method. Multivariate linear models were used to examine the associations (Ptrend and interactions (Pi. Results None of the SNPs showed a statistically significant association with AD. However, each additional rare allele of rs1056836 CYP1B1 was associated with a reduction in AD among nulliparous women (Ptrend = 0.004, while no association was observed among parous women (Ptrend = 0.62; Pi = 0.02. An increase in the number of rare alleles of the HSD17B1 SNP (rs598126 and rs2010750 was associated with an increase in AD among women who never used hormonal derivatives (Ptrend = 0.06 and Ptrend = 0.04, respectively, but with a decrease in AD among past hormonal derivatives users (Ptrend = 0.04; Pi = 0.02 and Ptrend = 0.08; Pi = 0.01, respectively. Moreover, a negative association of rs598126 HSD17B1 SNP with AD was observed among women with higher BMI (>median (Ptrend = 0.01; Pi = 0.02. A negative association between an increased number of rare alleles of COMT rs4680 SNP and AD was limited to women who never used hormonal derivatives (Ptrend = 0.02; Pi = 0.03 or with late age at menarche (>median

  16. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect

    International Nuclear Information System (INIS)

    Napolitano, Mary E.; Trueblood, Jon H.; Hertel, Nolan E.; David, George

    2002-01-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within ±1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  17. Digital Breast Tomosynthesis versus Supplemental Diagnostic Mammographic Views for Evaluation of Noncalcified Breast Lesions

    Science.gov (United States)

    Bandos, Andriy I.; Ganott, Marie A.; Sumkin, Jules H.; Kelly, Amy E.; Catullo, Victor J.; Rathfon, Grace Y.; Lu, Amy H.; Gur, David

    2013-01-01

    Purpose: To compare the diagnostic performance of breast tomosynthesis versus supplemental mammography views in classification of masses, distortions, and asymmetries. Materials and Methods: Eight radiologists who specialized in breast imaging retrospectively reviewed 217 consecutively accrued lesions by using protocols that were HIPAA compliant and institutional review board approved in 182 patients aged 31–60 years (mean, 50 years) who underwent diagnostic mammography and tomosynthesis. The lesions in the cohort included 33% (72 of 217) cancers and 67% (145 of 217) benign lesions. Eighty-four percent (182 of 217) of the lesions were masses, 11% (25 of 217) were asymmetries, and 5% (10 of 217) were distortions that were initially detected at clinical examination in 8% (17 of 217), at mammography in 80% (173 of 217), at ultrasonography (US) in 11% (25 of 217), or at magnetic resonance imaging in 1% (2 of 217). Histopathologic examination established truth in 191 lesions, US revealed a cyst in 12 lesions, and 14 lesions had a normal follow-up. Each lesion was interpreted once with tomosynthesis and once with supplemental mammographic views; both modes included the mediolateral oblique and craniocaudal views in a fully crossed and balanced design by using a five-category Breast Imaging Reporting and Data System (BI-RADS) assessment and a probability-of-malignancy score. Differences between modes were analyzed with a generalized linear mixed model for BI-RADS–based sensitivity and specificity and with modified Obuchowski-Rockette approach for probability-of-malignancy–based area under the receiver operating characteristic (ROC) curve. Results: Average probability-of-malignancy–based area under the ROC curve was 0.87 for tomosynthesis versus 0.83 for supplemental views (P tomosynthesis, the false-positive rate decreased from 85% (989 of 1160) to 74% (864 of 1160) (P tomosynthesis, more cancers were classified as BI-RADS category 5 (39% [226 of 576] vs 33% [188

  18. Index of film reject rates of mammographic service of Hospital Geral do Mexico. Strategies and results

    International Nuclear Information System (INIS)

    Jaimes, Uriel; Fabela, Arturo; Ramirez, Raul; Robledo, Rogelio; Verdejo, Maricela

    2001-01-01

    The reject of a radiographic film, not just means to do it again with the consequent increase in the dose to the patient, also means a failure in the service, as factors like fault in the equipment or by humans factors, like the selection of inadequate techniques or the bad positioning of the patient. In both cases, the analysis of the reject measures of radiographic studies, take special importance in the mammographic area, mainly if we consider the radiosensitivity of the tissues in study. This work, shows the methodology and the results of a study carried out in the Oncology Department of the General Hospital of Mexico, the biggest in the state, with the objective of knowing the principal causes of reject of films and establish through the respective analysis, the actions for correcting the detected failures, assuring so, low doses to patient, more precise diagnostic and the reduction of operating costs, that are the main objectives in a Program of Quality Assurance in Radiodiagnostic. (author)

  19. Ambient dose evaluation at mammographic installations through the spectrum of barrier transmitted beams

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Costa, Paulo R.; Herdade, Silvio B.; Furquim, Tania A.C.; Terini, Ricardo A.

    2001-01-01

    National regulations (Ministerial Rule 453, 1998) state that ambient dose equivalent (ADE) must be the operational quantity to verify the conformance with dose constraint levels in area surveys. It's difficulty to evaluate ADE's through conventional radiometric measurements performed in the neighbor areas of examination room because of the low energy levels utilized by mammographic equipment. Therefore, it is necessary to know the radiation spectrum incident in the area. Spectra of X-rays scattered by a breast tissue equivalent phantom have been measured in a controlled area adjacent to a mammography room, using a portable high resolution spectrometer, and taking into account typical workload distributions. The raw spectra was corrected for changes of detector efficiency with photon energy and converted to fluence units (photons/keV.m 2 ). After, air kerma values (in mGy/m As) was calculated for each corrected spectrum. The ADE's (in mSv/year) was obtained by two ways: firstly using the constant conversion factor 1.14 Sv/Gy, adopted by the Ministerial Rule 453 and used in ionization chambers; secondly, through the conversion factor (Sv/Gy) versus energy curve. Results show clearly that the ADE values are overestimated when adopting the usual methodology and that the proposed method furnishes more realistic data for the evaluation of protective shielding. (author)

  20. Mammographic findings after breast cancer treatment with local excision and definitive irradiation

    International Nuclear Information System (INIS)

    Dershaw, D.D.; Shank, B.; Reisinger, S.

    1987-01-01

    Following local excision and definitive irradiation of 163 breast cancers in 160 women, alterations in mammographic patterns were observed for up to 7 years. Skin thickening was observed in 96% of mammograms obtained within 1 year of completing therapy and was most pronounced in women treated with iridium implant, chemotherapy, or axillary dissection. In 76% of mammograms, alterations in the parenchymal pattern, including coarsening of stroma and increased breast density, were seen at 1 year. Neither skin nor parenchymal changes progressed after 1 year. Within 3 years of treatment the parenchymal density, which usually regressed, did not change in all patients. At 3 years skin thickness and the parenchymal pattern had returned to normal in less than 50% of the breasts of these women. Scars developed in approximately one-quarter of women. They were present on the initial post-treatment mammogram and remained unchanged on serial studies. Coarse, benign calcifications also developed in the breasts of about one-quarter of women. Microcalcifications developed in 11 breasts; biopsy specimens of six were benign. Benign microcalcifications may be related to therapy

  1. Predictive modeling of human perception subjectivity: feasibility study of mammographic lesion similarity

    Science.gov (United States)

    Xu, Songhua; Hudson, Kathleen; Bradley, Yong; Daley, Brian J.; Frederick-Dyer, Katherine; Tourassi, Georgia

    2012-02-01

    The majority of clinical content-based image retrieval (CBIR) studies disregard human perception subjectivity, aiming to duplicate the consensus expert assessment of the visual similarity on example cases. The purpose of our study is twofold: i) discern better the extent of human perception subjectivity when assessing the visual similarity of two images with similar semantic content, and (ii) explore the feasibility of personalized predictive modeling of visual similarity. We conducted a human observer study in which five observers of various expertise were shown ninety-nine triplets of mammographic masses with similar BI-RADS descriptors and were asked to select the two masses with the highest visual relevance. Pairwise agreement ranged between poor and fair among the five observers, as assessed by the kappa statistic. The observers' self-consistency rate was remarkably low, based on repeated questions where either the orientation or the presentation order of a mass was changed. Various machine learning algorithms were explored to determine whether they can predict each observer's personalized selection using textural features. Many algorithms performed with accuracy that exceeded each observer's self-consistency rate, as determined using a cross-validation scheme. This accuracy was statistically significantly higher than would be expected by chance alone (two-tailed p-value ranged between 0.001 and 0.01 for all five personalized models). The study confirmed that human perception subjectivity should be taken into account when developing CBIR-based medical applications.

  2. Digital mammographic tumor classification using transfer learning from deep convolutional neural networks.

    Science.gov (United States)

    Huynh, Benjamin Q; Li, Hui; Giger, Maryellen L

    2016-07-01

    Convolutional neural networks (CNNs) show potential for computer-aided diagnosis (CADx) by learning features directly from the image data instead of using analytically extracted features. However, CNNs are difficult to train from scratch for medical images due to small sample sizes and variations in tumor presentations. Instead, transfer learning can be used to extract tumor information from medical images via CNNs originally pretrained for nonmedical tasks, alleviating the need for large datasets. Our database includes 219 breast lesions (607 full-field digital mammographic images). We compared support vector machine classifiers based on the CNN-extracted image features and our prior computer-extracted tumor features in the task of distinguishing between benign and malignant breast lesions. Five-fold cross validation (by lesion) was conducted with the area under the receiver operating characteristic (ROC) curve as the performance metric. Results show that classifiers based on CNN-extracted features (with transfer learning) perform comparably to those using analytically extracted features [area under the ROC curve [Formula: see text

  3. Mammographic findings after reshaping with autoprosthesis in women undergoing contralateral breast reconstruction and mastectomy.

    Science.gov (United States)

    Scaperrotta, Gianfranco; Capalbo, Emanuela; Ferranti, Claudio; Falco, Giuseppe; Nava, Maurizio B; Di Leo, Gianni; Marchesini, Monica; Suman, Laura; Panizza, Pietro

    2016-01-01

    Breast reduction and mastopexy combined with inferior dermo-lipo-glandular flap (autoprosthesis) gives good breast shape, long-term projection, and upper pole fullness. We assess the impact on breast oncologic surveillance compared to other techniques. A total of 105 patients who underwent mastectomy and reconstruction were divided into 3 groups of 35 patients each: groups 1 and 2 include patients with contralateral breast symmetrization performed with and without autoprosthesis technique, respectively. Group 3 is a control group without contralateral breast reshaping. On mammography, edema, skin thickening, architectural distortion, and calcifications were recorded, as well as further diagnostic examinations, biopsies, and surgical treatments required. Statistically significant differences (p<0.001) in the first follow-up mammography between groups 1 and 2 were stromal edema (6% vs 51%) and architectural distortion (74% vs 63%). The latest findings meant architectural distortion also have significant difference (p<0.001) in the last mammography (79% vs 66%). Microcalcification has statistically significant difference (p<0.001) in the latest postsurgical mammography, increased in group 1. Skin thickening had a similar course in either group. Mammography follow-up was not impaired in most cases notwithstanding the parenchyma distortion as compared with mammography after breast-conserving surgery. Four core biopsies were performed in both groups: 3 new breast cancers and 1 benign epithelial hyperplasia were found. No difficulties were found impairing mammographic evaluation in patients treated with autoprosthesis as compared to other techniques.

  4. Mammographic Breast Density and Breast Cancer Molecular Subtypes: The Kenyan-African Aspect

    Directory of Open Access Journals (Sweden)

    Asim Jamal Shaikh

    2018-01-01

    Full Text Available Introduction. Data examining mammographic breast density (MBD among patients in Sub-Saharan Africa are sparse. We evaluated how MBD relates to breast cancer characteristics in Kenyan women undergoing diagnostic mammography. Methods. This cross-sectional study included women with pathologically confirmed breast cancers (n=123. Pretreatment mammograms of the unaffected breast were assessed to estimate absolute dense area (cm2, nondense area (cm2, and percent density (PD. Relationships between density measurements and clinical characteristics were evaluated using analysis of covariance. Results. Median PD and dense area were 24.9% and 85.3 cm2. Higher PD and dense area were observed in younger women (P<0.01. Higher dense and nondense areas were observed in obese women (P-trend < 0.01. Estrogen receptor (ER positive patients (73% had higher PD and dense area than ER-negative patients (P≤0.02. Triple negative breast cancer (TNBC patients (17% had lower PD and dense area (P≤0.01 compared with non-TNBCs. No associations were observed between MBD and tumor size and grade. Conclusions. Our findings show discordant relationships between MBD and molecular tumor subtypes to those previously observed in Western populations. The relatively low breast density observed at diagnosis may have important implications for cancer prevention initiatives in Kenya. Subsequent larger studies are needed to confirm these findings.

  5. Age as a predictive factor of mammographic breast density in Jamaican women

    International Nuclear Information System (INIS)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-01-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P -2 vs 26.0 ± 5.2 kg m -2 , P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  6. The effect of skin thickness determined using breast CT on mammographic dosimetry

    International Nuclear Information System (INIS)

    Huang Shihying; Boone, John M.; Yang, Kai; Kwan, Alexander L. C.; Packard, Nathan J.

    2008-01-01

    The effect of breast skin thickness on dosimetry in mammography was investigated. Breast computed tomography (CT) acquisition techniques, combined with algorithms designed for determining specific breast metrics, were useful for estimating skin thickness. A radial-geometry edge detection scheme was implemented on coronal reconstructed breast CT (bCT) images to measure the breast skin thickness. Skin thickness of bilateral bCT volume data from 49 women and unilateral bCT volume data from 2 women (10 healthy women and 41 women with BIRADS 4 and 5 diagnoses) was robustly measured with the edge detection scheme. The mean breast skin thickness (±inter-breast standard deviation) was found to be 1.45±0.30 mm. Since most current published normalized glandular dose (D gN ) coefficients are based on the assumption of a 4-mm breast skin thickness, the D gN values computed with Monte Carlo techniques will increase up to 18% due to the thinner skin layers (e.g., 6-cm 50% glandular breast, 28 kVp Mo-Mo spectrum). The thinner skin dimensions found in this study suggest that the current D gN values used for mammographic dosimetry lead to a slight underestimate in glandular dose

  7. Comparative study on mammographic findings between conventional mammography and digital mammography

    International Nuclear Information System (INIS)

    Gonzalez Calle, Aurelio; Saldarriaga Jaramillo, Ximena; Zapata Walliser, Luz Estela; Mejia Restrepo, Jorge Hernando; Arango Martinez, Adriana; Velez Arango, Jorge Mario

    2007-01-01

    We performed conventional-film mammograms in 180 patients between 35 and 6 years and additionally, we added 2 digital CR technique images to each patient, either craneocaudal (90 patients) or oblique (90 patients). All images were interpreted independently by four radiologists for a total of 720 evaluations, who compared film versus digital images through a 5 mega pixel monitor (soft-copy), using a score scale using the following parameters: mass visualization, detection of micro-calcifications, architectural distortion, visibility of the skin line, and image sharpness and noise. Additionally the tissue density was classified as well as the BIRADS score. The data was processed with the Teleform program and analyzed by de SPSSS program. Results: 52.6% of the micro-calcifications were equally visualized with both systems, in 13.5% of the cases they were better visualized with digital mammography. Similarly, in 50% of the cases, the skin line was better visualized with the digital CR modality. Conclusion: the sharpness of the image was also better seen with the digital CR technique in 48.2%. On the contrary, more noise was seen in digital CR images (63%). digital mammography is a diagnostic alternative that can improve mammographic findings detection and finally become a useful tool in breast cancer diagnosis

  8. Mammography and mammographic screening in the United Kingdom: Practices, regulations and radiation dosimetry

    International Nuclear Information System (INIS)

    Fitzgerald, M.

    1987-01-01

    The radiation-induced cancers due to mammography represent about 0.6 % of the natural incidence in this survey and would seem to be a very small risk. If the frequency or period of screening was increased, the risk would be enhanced. However, it should be possible to reduce the radiation dose to less than the mean value used here. For example, if film screen mammography alone was used for this population, the quoted risk would be reduced by 25%. The dose is also reduced by the use of a single view. The relatively low risk to the breast is a consequence partly of the low dose mammographic techniques that can now be practised, and partly of the acceptance of mean breast dose, which may be an order to magnitude less than the surface dose, as the measure of risk. The risk to other organs should be negligible provided that the X-ray field is carefully collimated and that the breast table incorporates a primary absorber

  9. Mammographic parenchymal patterns: value as a predictor of hormone dependency and survival in breast cancer

    International Nuclear Information System (INIS)

    Hinton, C.P.; Roebuck, E.J.; Williams, M.R.; Blamey, R.W.; Glaves, J.; Nicholson, R.I.; Griffiths, K.

    1985-01-01

    The relation between the parenchymal pattern of the breasts as demonstrated on a mammogram and the estrogen-receptor status of the primary tumor in 337 patients with operable invasive breast cancer has been studied. These factors have also been correlated with the response to endocrine therapy in 92 patients who subsequently developed secondary disease. It has been shown that patients with a DY pattern are more likely to develop tumors that are estrogen-receptor (ER) positive. Patients with secondary disease who have a DY pattern are more likely to respond to endocrine therapy. The DY pattern has been shown to be at least as good an indicator of the probability of response to endocrine therapy as the estrogen-receptor status, and a combination of the two factors better than either taken singly. In a series of 141 postmenopausal women, the DY pattern, as determined at the time of mastectomy, was associated with significantly improved survival. Mammographic parenchymal pattern could form the basis for selecting patients for endocrine therapy where no estrogen-receptor assay is available

  10. Pseudoangiomatous stromal hyperplasia: a study of the mammographic and sonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Celliers, L., E-mail: liesl.celliers@health.wa.gov.a [Department of Radiology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Wong, D.D. [PathWest Laboratory Medicine, Department of Anatomical Pathology, Nedlands, Western Australia (Australia); Bourke, A. [Department of Radiology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia)

    2010-02-15

    Aim: To review the imaging features on mammogram and ultrasound of pseudoangiomatous stromal hyperplasia (PASH) of the breast. Materials and methods: A systematic search of the breast cancer screening centre and pathology department database at a teaching hospital was performed to identify cases reported as PASH between 2000 and 2007. The findings on mammogram and ultrasound were reviewed. Information on demographics and clinical outcome were obtained from the patient's medical records. Results: Seventy-three cases of PASH were identified, which occurred in women with a mean age of 51.1 +- 10.5 years. The mean size of the lesion was 18 mm. Up to 70.8% of cases were radiologically detected and 29.2% presented as palpable masses. The most common appearance on mammography was of a solitary, non-calcified mass (30.4%) or localized increased stroma (30.4%). The distribution of mammographic findings differed in screen-detected patients compared with those presenting clinically (p = 0.015, Fisher's exact test). The most frequent sonographic appearance was of a well-defined hypoechoic mass (36.7%). Conclusion: Although there are emerging patterns associated with PASH on imaging, the features are not sufficiently specific to allow for a prospective diagnosis. Histological confirmation, preferably with core biopsy, should always be considered.

  11. Mammographic density and factors determining it from the point of view of high oncological risks

    Directory of Open Access Journals (Sweden)

    D. A. Vasilyev

    2011-01-01

    Full Text Available There is now extensive proof that high percentage of mammographic density (MD is an independent risk factor for breast cance.r Taking this into account, the research data are summarized with regard to relation of MD to anthropometric, as well as hormonal, genetic and genotoxic factors. There is a negative correlation between MD and such risk factors as age, number of deliveries, BMI and waist-hip ratio. Most inves- tigations show a direct connection between MD and prolactin level or insulin-like growth factor in blood, mostly in premenopaus al women. Relations of MD with blood estrogens, testosterone, sex hormone binding globulin prove to be too diverse to be taken in account of. It is pos- sible that the action of hormones, especially estrogens, is mediated through their metabolites catecholestrogens and / or reactive oxygen spe- cies. There is certain evidence that a genetic component plays a role in MD. It refers to COMT Val158Met, IGF-I rs6220 A> G and UGT1A1 in premenopausal women, and to ESR1 (XbaI и PvuII in menopausal cases.Although it is obvious that the risk of breast cancer related to MD is brought about by many factors, there is a necessity for studying addi- tional criteria modifying the process, as well as for searching means for preventing it.

  12. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeonok; Cho, Heemoon; Je, Uikyu; Cho, Hyosung, E-mail: hscho1@yonsei.ac.kr; Park, Chulkyu; Lim, Hyunwoo; Kim, Kyuseok; Kim, Guna; Park, Soyoung; Woo, Taeho; Choi, Sungil

    2015-12-21

    In this work, we have developed a prototype digital breast tomosynthesis (DBT) system which mainly consists of an x-ray generator (28 kV{sub p}, 7 mA s), a CMOS-type flat-panel detector (70-μm pixel size, 230.5×339 mm{sup 2} active area), and a rotational arm to move the x-ray generator in an arc. We employed a compressed-sensing (CS)-based reconstruction algorithm, rather than a common filtered-backprojection (FBP) one, for more accurate DBT reconstruction. Here the CS is a state-of-the-art mathematical theory for solving the inverse problems, which exploits the sparsity of the image with substantially high accuracy. We evaluated the reconstruction quality in terms of the detectability, the contrast-to-noise ratio (CNR), and the slice-sensitive profile (SSP) by using the mammographic accreditation phantom (Model 015, CIRS Inc.) and compared it to the FBP-based quality. The CS-based algorithm yielded much better image quality, preserving superior image homogeneity, edge sharpening, and cross-plane resolution, compared to the FBP-based one. - Highlights: • A prototype digital breast tomosynthesis (DBT) system is developed. • Compressed-sensing (CS) based reconstruction framework is employed. • We reconstructed high-quality DBT images by using the proposed reconstruction framework.

  14. Genotypes and haplotypes in the insulin-like growth factors, their receptors and binding proteins in relation to plasma metabolic levels and mammographic density

    Directory of Open Access Journals (Sweden)

    Chanock Stephen J

    2010-03-01

    Full Text Available Abstract Background Increased mammographic density is one of the strongest independent risk factors for breast cancer. It is believed that one third of breast cancers are derived from breasts with more than 50% density. Mammographic density is affected by age, BMI, parity, and genetic predisposition. It is also greatly influenced by hormonal and growth factor changes in a woman's life cycle, spanning from puberty through adult to menopause. Genetic variations in genes coding for hormones and growth factors involved in development of the breast are therefore of great interest. The associations between genetic polymorphisms in genes from the IGF pathway on mammographic density and circulating levels of IGF1, its binding protein IGFBP3, and their ratio in postmenopausal women are reported here. Methods Samples from 964 postmenopausal Norwegian women aged 55-71 years were collected as a part of the Tromsø Mammography and Breast Cancer Study. All samples were genotyped for 25 SNPs in IGF1, IGF2, IGF1R, IGF2R, IGFALS and IGFBP3 using Taqman (ABI. The main statistical analyses were conducted with the PROC HAPLOTYPE procedure within SAS/GENETICS™ (SAS 9.1.3. Results The haplotype analysis revealed six haploblocks within the studied genes. Of those, four had significant associations with circulating levels of IGF1 or IGFBP3 and/or mammographic density. One haplotype variant in the IGF1 gene was found to be associated with mammographic density. Within the IGF2 gene one haplotype variant was associated with levels of both IGF1 and IGFBP3. Two haplotype variants in the IGF2R were associated with the level of IGF1. Both variants of the IGFBP3 haplotype were associated with the IGFBP3 level and indicate regulation in cis. Conclusion Polymorphisms within the IGF1 gene and related genes were associated with plasma levels of IGF1, IGFBP3 and mammographic density in this study of postmenopausal women.

  15. [The effect of mammographic screening on tumor size, axillary node status and the degree of histologic anaplasia].

    Science.gov (United States)

    Garami, Zoltán; Benkó, Klára; Kósa, Csaba; Fülöp, Balázs; Lukács, Géza

    2006-10-01

    Breast cancer is the most frequent malignant tumor in women in Hungary. Significant reduction of mortality has been brought about not only by the increasing efficiency of complex therapy but also by regular mammographic screening. Of the histopathological data of 633 patients operated with primary breast tumor at the 1st Surgical Clinic of the Debrecen Medical University between January 1st 2000 and December 31st 2004, the authors analyzed tumor diameter, axillary node status and the degree of histologic anaplasia and compared them with the data of mammographic screening. Of the "screened"patients, 70.7% were diagnosed with T1 size tumors, 28.5% with T2 size, and 0.8% with tumors bigger than that. In the "unscreened" patients, our findings were 44.3%, 45.9% and 9.8% respectively. Within T1 tumors, Tla tumors were found in 11%, TIb in 37.6% and T1c in 51.4% in the "screened" group of patients, while the "unscreened" group's results were 2.3%, 12.6% and 85% respectively. 72.7% of the "screened" patients and 56.2% of the "unscreened" patients were found to be axillary node-negative. A study of the degree of histologic anaplasia showed G-I tumors in 15.6%, G-IIs in 62.1% and G-IIIs in 22.3% of the "screened" patients. The corresponding values for the "unscreened" patients were 6.1%, 53.8% and 40.1%, respectively. The differences were highly significant (p < 0.001) in all the parameters investigated. The authors have found a significant increase in the proportion of node-negative patients and patients with smaller tumors even after the first round of mammographic screening and at less than 50% participation. It is to be hoped that a 20% reduction in mortality can be achieved by further increasing the rate of participation.

  16. Improvement of Breast Cancer Detection Using Non-subsampled Contourlet Transform and Super-Resolution Technique in Mammographic Images

    Directory of Open Access Journals (Sweden)

    Fatemeh Pak

    2015-05-01

    Full Text Available Introduction Breast cancer is one of the most life-threatening conditions among women. Early detection of this disease is the only way to reduce the associated mortality rate. Mammography is a standard method for the early detection of breast cancer. Today, considering the importance of breast cancer detection, computer-aided detection techniques have been employed to increase the quality of mammographic images and help physicians reduce false positive rate (FPR. Materials and Methods In this study, a method was proposed for improving the quality of mammographic images to help radiologists establish a prompt and accurate diagnosis. The proposed approach included three major parts including pre-processing, feature extraction, and classification. In the pre-processing stage, the region of interest was determined and the image quality was improved by non-subsampled contourlet transform and super-resolution algorithm. In the feature extraction stage, some features of image components were extracted and skewness of each feature was calculated. Finally, a support vector machine was utilized to classify the features and determine the probability of benignity or malignancy of the disease. Results Based on the obtained results using Mammographic Image Analysis Society (MIAS database, the mean accuracy was estimated at 87.26% and maximum accuracy was 96.29%. Also, the mean and minimum FPRs were estimated at 9.55% and 2.87%, respectively.     Conclusion The results obtained using MIAS database indicated the superiority of the proposed method to other techniques. The reduced FPR in the proposed method was a significant finding in the present article.

  17. Polymorphisms in genes involved in the estrogen pathway and mammographic density

    International Nuclear Information System (INIS)

    Dumas, Isabelle; Diorio, Caroline

    2010-01-01

    Single nucleotide polymorphisms (SNPs) in genes involved in the estrogen pathway appear to be associated with breast cancer risk and possibly with mammographic density (MD), but little is known of these associations among premenopausal women. This study examines the association of 11 polymorphisms in five estrogen-related genes (estrogen receptors alpha and beta (ERα, ERβ), 17β-hydroxysteroid dehydrogenase 1 (HSD17B1), catechol-O-methyltransferase (COMT), cytochrome P450 1B1 (CYP1B1)) with premenopausal MD. Effect modification of four estrogen-related factors (parity, age at menarche, hormonal derivatives use and body mass index (BMI)) on this relation is also assessed. Polymorphisms were genotyped in 741 premenopausal Caucasian women whose MD was measured in absolute density (AD, cm 2 ) and percent density using a computer-assisted method. Multivariate linear models were used to examine the associations (P trend ) and interactions (P i ). None of the SNPs showed a statistically significant association with AD. However, each additional rare allele of rs1056836 CYP1B1 was associated with a reduction in AD among nulliparous women (P trend = 0.004), while no association was observed among parous women (P trend = 0.62; P i = 0.02). An increase in the number of rare alleles of the HSD17B1 SNP (rs598126 and rs2010750) was associated with an increase in AD among women who never used hormonal derivatives (P trend = 0.06 and P trend = 0.04, respectively), but with a decrease in AD among past hormonal derivatives users (P trend = 0.04; P i = 0.02 and P trend = 0.08; P i = 0.01, respectively). Moreover, a negative association of rs598126 HSD17B1 SNP with AD was observed among women with higher BMI (>median) (P trend = 0.01; P i = 0.02). A negative association between an increased number of rare alleles of COMT rs4680 SNP and AD was limited to women who never used hormonal derivatives (P trend = 0.02; P i = 0.03) or with late age at menarche (>median) (P trend = 0.03; P i

  18. Estimation of the prognostic value of some clinical factors and mammographical signs in breast cancer

    International Nuclear Information System (INIS)

    Luczynska, E.; Aniol, J.; Dyczek, S.; Mitus, J.; Stelmach, A.; Sokolowski, A.

    2006-01-01

    The aim of the work is to assess the probability of the breast cancer occurrence on the basis of analysis of the clinical and mammographical factors in women with unpalpable breast tumor. In the period from the 1 st February 1995 to the 31 st August 2000, 163 surgical procedures for the removal of any lesions in the breasts were conducted, after being previously marked by localized needle, in women who earlier underwent mammography exam.Following data was taken into consideration: patients age, type of the breast structure; side of the breast, where the lesion was localized in the mammography exam; localized lesions depending on the quadrant; shape of the lesion; size of the lesion in millimeters; presence and the type of microcalcifications. 1. The only one population factor, which can be distinguished as characteristic for the women suffering from the breast cancer impalpable in clinical testing, is the age of the patient, because the breast cancer in these women more frequently occurs after 53 years of age. 2. On the basis of our own material the following radiological symptoms characteristic for the breast cancer in mammography exam were stated: the breast cancer is more frequently found in the upper external quadrant; all lesions, which in mammography exam were identified as multifocal and radiologically suspected in histopathology exam turned out to be the cancer; pleomorphic microcalcifications are characteristic for the malignant lesions; external outline and the shape of the lesion are the features, which allow to differentiate malignant and benign lesions. 3. The analysis of the material indicates that the greatest probability of the breast cancer occurrence is in case of the four risk factors occurrence simultaneously, and the smallest in case of only one risk factor occurrence. (author)

  19. Mammographic and Ultrasonographic Findings of Oxidized Regenerated Cellulose in Breast Cancer Surgery: A 5-Year Experience.

    Science.gov (United States)

    Giuliani, Michela; Fubelli, Rita; Patrolecco, Federica; Rella, Rossella; Borelli, Cristina; Buccheri, Chiara; Di Giovanni, Silvia Eleonora; Belli, Paolo; Romani, Maurizio; Rinaldi, Pierluigi; Bufi, Enida; Franceschini, Gianluca; Bonomo, Lorenzo

    2015-10-01

    The purpose of this study was to describe the ultrasonographic (US) and mammographic (MX) findings in patients who underwent breast-conserving surgery followed by oxidized regenerated cellulose (ORC) implantation in the surgical cavity and their size variations in follow-up. We retrospectively reviewed 417 MX and 743 US images performed between January 2009 and January 2014 for 262 women who underwent breast-conserving surgery. All patients underwent US, only 203 women underwent MX examination. In 170 of 262 patients, US examinations showed abnormal findings. Three main US patterns were identified: (1) complex masses: well-encapsulated ipoisoechoic lesions with circumscribed margins with internal hyperechoic nodules (56%); (2) hypoanechoic lesions without internal hyperechoic nodules (24%); and (3) completely anechoic collections (20%). Moreover, Doppler ultrasound examination was performed on all of the patients. In 95 of 203 patients, MX examinations showed abnormalities. Four main MX patterns were identified: (1) round or oval opacity with circumscribed margins (58%); (2) round or oval opacity with indistinct or ill-defined margins (17%); (3) irregular opacity with indistinct or spiculated margins (9%); and (4) architectural distortion or focal asymmetry (15%). Most of the lesions showed a decrease in size at US and MX follow-up examination and the decrease was statistically significant (P < .01). When applied to the surgical residual cavity, ORC aids to control local hemorrhage and reduce the risk of postoperative infections, but can lead to alterations in surgical scar. Thus, knowledge of the radiological findings might allow avoidance of misdiagnosis of tumor recurrence or unnecessary diagnostic examinations. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. The effect of change in body mass index on volumetric measures of mammographic density

    Science.gov (United States)

    Hart, Vicki; Reeves, Katherine W.; Sturgeon, Susan R.; Reich, Nicholas G.; Sievert, Lynnette Leidy; Kerlikowske, Karla; Ma, Lin; Shepherd, John; Tice, Jeffrey A.; Mahmoudzadeh, Amir Pasha; Malkov, Serghei; Sprague, Brian L.

    2015-01-01

    Background Understanding how changes in body mass index (BMI) relate to changes in mammographic density is necessary to evaluate adjustment for BMI gain/loss in studies of change in density and breast cancer risk. Increase in BMI has been associated with a decrease in percent density, but the effect on change in absolute dense area or volume is unclear. Methods We examined the association between change in BMI and change in volumetric breast density among 24,556 women in the San Francisco Mammography Registry from 2007-2013. Height and weight were self-reported at the time of mammography. Breast density was assessed using single x-ray absorptiometry measurements. Cross-sectional and longitudinal associations between BMI and dense volume (DV), non-dense volume (NDV) and percent dense volume (PDV) were assessed using multivariable linear regression models, adjusted for demographics, risk factors, and reproductive history. Results In cross-sectional analysis, BMI was positively associated with DV (β=2.95 cm3, 95% CI 2.69, 3.21) and inversely associated with PDV (β=-2.03%, 95% CI -2.09, -1.98). In contrast, increasing BMI was longitudinally associated with a decrease in both DV (β=-1.01 cm3, 95% CI -1.59, -0.42) and PDV (β=-1.17%, 95% CI -1.31, -1.04). These findings were consistent for both pre- and postmenopausal women. Conclusion Our findings support an inverse association between change in BMI and change in PDV. The association between increasing BMI and decreasing DV requires confirmation. Impact Longitudinal studies of PDV and breast cancer risk, or those using PDV as an indicator of breast cancer risk, should evaluate adjustment for change in BMI. PMID:26315554

  1. Investigation of mammographic breast density as a risk factor for ovarian cancer.

    Science.gov (United States)

    Wernli, Karen J; O'Meara, Ellen S; Kerlikowske, Karla; Miglioretti, Diana L; Muller, Carolyn Y; Onega, Tracy; Sprague, Brian L; Henderson, Louise M; Buist, Diana S M

    2014-01-01

    Endogenous hormones and growth factors that increase mammographic breast density could increase ovarian cancer risk. We examined whether high breast density is associated with ovarian cancer risk. We conducted a cohort study of 724,603 women aged 40 to 79 years with 2,506,732 mammograms participating in the Breast Cancer Surveillance Consortium from 1995 to 2009. Incident epithelial ovarian cancer was diagnosed in 1373 women. We used partly conditional Cox regression to estimate the association between breast density and 5-year risk of incident epithelial ovarian cancer overall and stratified by 10-year age group. All statistical tests were two-sided. Compared with women with scattered fibroglandular densities, women with heterogeneously dense and extremely dense breast tissue had 20% and 18% increased 5-year risk of incident epithelial ovarian cancer (hazard ratio [HR] = 1.20, 95% confidence interval [CI] = 1.06 to 1.36; HR = 1.18, 95% CI = 0.93 to 1.50, respectively; P(trend) = .01). Among women aged 50 to 59 years, we observed a trend in elevated risk associated with increased breast density (P(trend) = .02); women with heterogeneously and extremely dense breast tissue had 30% (HR = 1.30; 95% CI = 1.03 to 1.64) and 65% (HR = 1.65; 95% CI = 1.12 to 2.44) increased risk, respectively, compared with women with scattered fibroglandular densities. The pattern was similar but not statistically significant at age 40 to 49 years. There were no consistent patterns of breast density and ovarian cancer risk at age 60 to 79 years. Dense breast tissue was associated with a modest increase in 5-year ovarian cancer risk in women aged 50 to 59 years but was not associated with ovarian cancer at ages 40 to 49 or 60 to 79 years.

  2. Role of ultrasonography in detecting mammographically occult breast carcinoma in women with dense breasts.

    Science.gov (United States)

    Corsetti, V; Ferrari, A; Ghirardi, M; Bergonzini, R; Bellarosa, S; Angelini, O; Bani, C; Ciatto, S

    2006-04-01

    The purpose of this study was to assess the usefulness of routine ultrasonography in women with negative mammography and dense breasts [Breast Imaging Reporting and Data System (BIRADS D3-4)]. We applied a protocol involving routine ultrasonography in a consecutive series of subjects with negative mammography and dense breasts. After evaluation by internal and external reviewers of cancers detected by ultrasonography performed to confirm negative mammography, we determined the additional cancer detection rate of ultrasonography and the cost of the protocol. Out of 17,883 total mammographies, 167 cancers were diagnosed (detection rate: 0.93%). Out of 257 suspicious mammographies, 138 cancers were detected. Out of 17,626 negative mammographies, 6,449 (36.5%) were classified as "dense breast" and underwent ultrasonography: 29 cancers were detected (detection rate: 0.44%, or 17.3% of total cancers). Out of 25 cancer cases reviewed, negative mammography and asymptomatic status was confirmed in 15 (detection rate 0.23%, or 8.9% of total cancers). The cancer detection rate was 0.11%, 0.22%, 0.32% and 0.14% for age groups 59, respectively. The cost per additional carcinoma detected by ultrasonography alone was euro 25,847.85 whereas that per examined woman was euro 21.68. The study confirms the possibility that ultrasonography can detect mammographically occult breast carcinoma in dense breasts. The evidence is insufficient to recommend this policy in routine screening practice but suggests that, at least in current clinical practice, adding ultrasonography in dense breasts may be useful despite the substantial costs.

  3. Age as a predictive factor of mammographic breast density in Jamaican women

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-06-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P < 0.001). Women with low breast density were heavier (81.3 {+-} 15.5 kg vs 68.4 {+-} 14.3 kg,P < 0.0001, mean {+-} standard deviation (SD)) and more obese (body mass index (BMI), 30.3 {+-} 5.8 kg m{sup -2} vs 26.0 {+-} 5.2 kg m{sup -2}, P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  4. Comparison of subjective and fully automated methods for measuring mammographic density.

    Science.gov (United States)

    Moshina, Nataliia; Roman, Marta; Sebuødegård, Sofie; Waade, Gunvor G; Ursin, Giske; Hofvind, Solveig

    2018-02-01

    Background Breast radiologists of the Norwegian Breast Cancer Screening Program subjectively classified mammographic density using a three-point scale between 1996 and 2012 and changed into the fourth edition of the BI-RADS classification since 2013. In 2015, an automated volumetric breast density assessment software was installed at two screening units. Purpose To compare volumetric breast density measurements from the automated method with two subjective methods: the three-point scale and the BI-RADS density classification. Material and Methods Information on subjective and automated density assessment was obtained from screening examinations of 3635 women recalled for further assessment due to positive screening mammography between 2007 and 2015. The score of the three-point scale (I = fatty; II = medium dense; III = dense) was available for 2310 women. The BI-RADS density score was provided for 1325 women. Mean volumetric breast density was estimated for each category of the subjective classifications. The automated software assigned volumetric breast density to four categories. The agreement between BI-RADS and volumetric breast density categories was assessed using weighted kappa (k w ). Results Mean volumetric breast density was 4.5%, 7.5%, and 13.4% for categories I, II, and III of the three-point scale, respectively, and 4.4%, 7.5%, 9.9%, and 13.9% for the BI-RADS density categories, respectively ( P for trend density categories was k w  = 0.5 (95% CI = 0.47-0.53; P density increased with increasing density category of the subjective classifications. The agreement between BI-RADS and volumetric breast density categories was moderate.

  5. Vision 20/20: Mammographic breast density and its clinical applications

    International Nuclear Information System (INIS)

    Ng, Kwan-Hoong; Lau, Susie

    2015-01-01

    Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which women are “dense” and what imaging modality is suitable for individual women. To date, mammographic breast density has been classified according to the Breast Imaging-Reporting and Data System (BI-RADS) categories from visual assessment, but this is known to be very subjective. Despite many research reports, the authors believe there has been a lack of physics-led and evidence-based arguments about what breast density actually is, how it should be measured, and how it should be used. In this paper, the authors attempt to start correcting this situation by reviewing the history of breast density research and the debates generated by the advocacy movement. The authors review the development of breast density estimation from pattern analysis to area-based analysis, and the current automated volumetric breast density (VBD) analysis. This is followed by a discussion on seeking the ground truth of VBD and mapping volumetric methods to BI-RADS density categories. The authors expect great improvement in VBD measurements that will satisfy the needs of radiologists, epidemiologists, surgeons, and physicists. The authors believe that they are now witnessing a paradigm shift toward personalized breast screening, which is going to see many more cancers being detected early, with the use of automated density measurement tools as an important component

  6. Cost-effectiveness of annual versus biennial screening mammography for women with high mammographic breast density.

    Science.gov (United States)

    Pataky, Reka; Ismail, Zahra; Coldman, Andrew J; Elwood, Mark; Gelmon, Karen; Hedden, Lindsay; Hislop, Greg; Kan, Lisa; McCoy, Bonnie; Olivotto, Ivo A; Peacock, Stuart

    2014-12-01

    The sensitivity of screening mammography is much lower among women who have dense breast tissue, compared with women who have largely fatty breasts, and they are also at much higher risk of developing the disease. Increasing mammography screening frequency from biennially to annually has been suggested as a policy option to address the elevated risk in this population. The purpose of this study was to assess the cost-effectiveness of annual versus biennial screening mammography among women aged 50-79 with dense breast tissue. A Markov model was constructed based on screening, diagnostic, and treatment pathways for the population-based screening and cancer care programme in British Columbia, Canada. Model probabilities and screening costs were calculated from screening programme data. Costs for breast cancer treatment were calculated from treatment data, and utility values were obtained from the literature. Incremental cost-effectiveness was expressed as cost per quality adjusted life year (QALY), and probabilistic sensitivity analysis was conducted. Compared with biennial screening, annual screening generated an additional 0.0014 QALYs (95% CI: -0.0480-0.0359) at a cost of $819 ($ = Canadian dollars) per patient (95% CI: 506-1185), resulting in an incremental cost effectiveness ratio of $565,912/QALY. Annual screening had a 37.5% probability of being cost-effective at a willingness-to-pay threshold of $100,000/QALY. There is considerable uncertainty about the incremental cost-effectiveness of annual mammography. Further research on the comparative effectiveness of screening strategies for women with high mammographic breast density is warranted, particularly as digital mammography and density measurement become more widespread, before cost-effectiveness can be reevaluated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    Science.gov (United States)

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  8. Common genetic variation and novel loci associated with volumetric mammographic density.

    Science.gov (United States)

    Brand, Judith S; Humphreys, Keith; Li, Jingmei; Karlsson, Robert; Hall, Per; Czene, Kamila

    2018-04-17

    Mammographic density (MD) is a strong and heritable intermediate phenotype of breast cancer, but much of its genetic variation remains unexplained. We conducted a genetic association study of volumetric MD in a Swedish mammography screening cohort (n = 9498) to identify novel MD loci. Associations with volumetric MD phenotypes (percent dense volume, absolute dense volume, and absolute nondense volume) were estimated using linear regression adjusting for age, body mass index, menopausal status, and six principal components. We also estimated the proportion of MD variance explained by additive contributions from single-nucleotide polymorphisms (SNP-based heritability [h 2 SNP ]) in 4948 participants of the cohort. In total, three novel MD loci were identified (at P associated with breast cancer in available meta-analysis data including 122,977 breast cancer cases and 105,974 control subjects (P < 0.05). h 2 SNP (SE) estimates for percent dense, absolute dense, and nondense volume were 0.29 (0.07), 0.31 (0.07), and 0.25 (0.07), respectively. Corresponding ratios of h 2 SNP to previously observed narrow-sense h 2 estimates in the same cohort were 0.46, 0.72, and 0.41, respectively. These findings provide new insights into the genetic basis of MD and biological mechanisms linking MD to breast cancer risk. Apart from identifying three novel loci, we demonstrate that at least 25% of the MD variance is explained by common genetic variation with h 2 SNP /h 2 ratios varying between dense and nondense MD components.

  9. Stage distribution of breast cancer diagnosed before and after implementation of population-based mammographic screening

    International Nuclear Information System (INIS)

    Hofvind, S.; Skaane, P.

    2012-01-01

    Purpose: The German mammographic screening program is very similar to the Norwegian Breast Cancer Screening Program (NBCSP), which started about 10 years earlier. This study analyzes the stage distribution of invasive breast cancers diagnosed in the pre-screening and screening period, and evaluates the overall mortality in women aged 55 - 74 in the pilot and non-pilot counties of the NBCSP. Materials and Methods: The NBCSP invites women aged 50 - 69 to participate in two-view mammography biennially. Chi-square statistics were used to compare percentages of the stage and treatment of invasive breast cancers diagnosed in women residing in the four pilot counties in the pre-screening (1984 - 1995) and screening (1996 - 2007) period. An ecological approach was used to analyze the age-specific mortality in the pilot and non-pilot counties for the period 1970 - 2007. Results: 50 % of the breast cancers diagnosed in the pre-screening period, 70 % of the cases detected with screening, 43 % of the interval cancers, and 52 % of the cancers diagnosed outside the NBCSP were stage I. Stage III + was present in 11 % of the cancers in the pre-screening period, and in 1 % of the cancers detected with screening. In the screening period, the breast cancer mortality rate decreased substantially more in the pilot counties than in the non-pilot counties. Conclusion: The stage distribution of breast cancer diagnosed in the NBCSP is prognostically favorable compared to cancers diagnosed outside the screening program. The reduction in the breast cancer mortality rate was more pronounced in the four pilot counties compared to the non-pilot counties. It is necessary to evaluate the program based on individual data. (orig.)

  10. Vision 20/20: Mammographic breast density and its clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan-Hoong, E-mail: ngkh@ummc.edu.my; Lau, Susie [Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-12-15

    Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which women are “dense” and what imaging modality is suitable for individual women. To date, mammographic breast density has been classified according to the Breast Imaging-Reporting and Data System (BI-RADS) categories from visual assessment, but this is known to be very subjective. Despite many research reports, the authors believe there has been a lack of physics-led and evidence-based arguments about what breast density actually is, how it should be measured, and how it should be used. In this paper, the authors attempt to start correcting this situation by reviewing the history of breast density research and the debates generated by the advocacy movement. The authors review the development of breast density estimation from pattern analysis to area-based analysis, and the current automated volumetric breast density (VBD) analysis. This is followed by a discussion on seeking the ground truth of VBD and mapping volumetric methods to BI-RADS density categories. The authors expect great improvement in VBD measurements that will satisfy the needs of radiologists, epidemiologists, surgeons, and physicists. The authors believe that they are now witnessing a paradigm shift toward personalized breast screening, which is going to see many more cancers being detected early, with the use of automated density measurement tools as an important component.

  11. Polymorphism in cytochrome P450 1A2 and their interaction with risk factors in determining risk of squamous cell lung carcinoma in men.

    Science.gov (United States)

    Singh, Arvind P; Pant, Mohan C; Ruwali, Munindra; Shah, Parag P; Prasad, Rajendra; Mathur, Neeraj; Parmar, Devendra

    The present case-control study was carried out to investigate the association of functionally important polymorphisms of cytochrome P450 1A2 (CYP1A2) involved in the metabolic activation of tobacco derived procarcinogens with squamous cell carcinoma (SCC) of lung in North Indian men. The study consisted of 200 male cases with SCC of lung and an equal number of age and sex matched healthy controls. Our data showed that variant genotype of CYP1A2*1D and CYP1A2*1F were significantly associated with increased susceptibility to SCC of lung. Likewise, GSTM1 null genotype was found to be over represented in patients when compared to controls. Haplotype analysis revealed that haplotype, G-Tdel-T-C was significantly associated with risk to SCC of lung. Moreover, a significant increase in the risk to SCC of lung in the cases carrying combination of variant genotype of CYP1A2 with either CYP1A1 or GSTM1 have shown that gene-gene interactions may play an important role in squamous cell lung cancer risk. Our data also revealed that smokers or tobacco chewers carrying variant alleles of either CYP1A2*1D or CYP1A2*1F were at increased risk to SCC of lung, further demonstrating that CYP1A2 genotypes interact with environmental risk factors in enhancing the risk to squamous cell lung carcinoma.

  12. Inhibitory Effects of Dimethyllirioresinol, Epimagnolin A, Eudesmin, Fargesin, and Magnolin on Cytochrome P450 Enzyme Activities in Human Liver Microsomes

    Directory of Open Access Journals (Sweden)

    Ju-Hyun Kim

    2017-05-01

    Full Text Available Magnolin, epimagnolin A, dimethyllirioresinol, eudesmin, and fargesin are pharmacologically active tetrahydrofurofuranoid lignans found in Flos Magnoliae. The inhibitory potentials of dimethyllirioresinol, epimagnolin A, eudesmin, fargesin, and magnolin on eight major human cytochrome P450 (CYP enzyme activities in human liver microsomes were evaluated using liquid chromatography–tandem mass spectrometry to determine the inhibition mechanisms and inhibition potency. Fargesin inhibited CYP2C9-catalyzed diclofenac 4’-hydroxylation with a Ki value of 16.3 μM, and it exhibited mechanism-based inhibition of CYP2C19-catalyzed [S]-mephenytoin 4’-hydroxylation (Ki, 3.7 μM; kinact, 0.102 min−1, CYP2C8-catalyzed amodiaquine N-deethylation (Ki, 10.7 μM; kinact, 0.082 min−1, and CYP3A4-catalyzed midazolam 1’-hydroxylation (Ki, 23.0 μM; kinact, 0.050 min−1 in human liver microsomes. Fargesin negligibly inhibited CYP1A2-catalyzed phenacetin O-deethylation, CYP2A6-catalyzed coumarin 7-hydroxylation, CYP2B6-catalyzed bupropion hydroxylation, and CYP2D6-catalyzed bufuralol 1’-hydroxylation at 100 μM in human liver microsomes. Dimethyllirioresinol weakly inhibited CYP2C19 and CYP2C8 with IC50 values of 55.1 and 85.0 μM, respectively, without inhibition of CYP1A2, CYP2A6, CYP2B6, CYP2C9, CYP2D6, and CYP3A4 activities at 100 μM. Epimagnolin A, eudesmin, and magnolin showed no the reversible and time-dependent inhibition of eight major CYP activities at 100 μM in human liver microsomes. These in vitro results suggest that it is necessary to investigate the potentials of in vivo fargesin-drug interaction with CYP2C8, CYP2C9, CYP2C19, and CYP3A4 substrates.

  13. Study of quality perception in medical images based on comparison of contrast enhancement techniques in mammographic images

    Science.gov (United States)

    Matheus, B.; Verçosa, L. B.; Barufaldi, B.; Schiabel, H.

    2014-03-01

    With the absolute prevalence of digital images in mammography several new tools became available for radiologist; such as CAD schemes, digital zoom and contrast alteration. This work focuses in contrast variation and how the radiologist reacts to these changes when asked to evaluated image quality. Three contrast enhancing techniques were used in this study: conventional equalization, CCB Correction [1] - a digitization correction - and value subtraction. A set of 100 images was used in tests from some available online mammographic databases. The tests consisted of the presentation of all four versions of an image (original plus the three contrast enhanced images) to the specialist, requested to rank each one from the best up to worst quality for diagnosis. Analysis of results has demonstrated that CCB Correction [1] produced better images in almost all cases. Equalization, which mathematically produces a better contrast, was considered the worst for mammography image quality enhancement in the majority of cases (69.7%). The value subtraction procedure produced images considered better than the original in 84% of cases. Tests indicate that, for the radiologist's perception, it seems more important to guaranty full visualization of nuances than a high contrast image. Another result observed is that the "ideal" scanner curve does not yield the best result for a mammographic image. The important contrast range is the middle of the histogram, where nodules and masses need to be seen and clearly distinguished.

  14. CYP1-mediated antiproliferative activity of dietary flavonoids in MDA-MB-468 breast cancer cells

    International Nuclear Information System (INIS)

    Androutsopoulos, Vasilis P.; Ruparelia, Ketan; Arroo, Randolph R.J.; Tsatsakis, Aristidis M.; Spandidos, Demetrios A.

    2009-01-01

    Among the different mechanisms proposed to explain the cancer-protecting effect of dietary flavonoids, substrate-like interactions with cytochrome P450 CYP1 enzymes have recently been explored. In the present study, the metabolism of the flavonoids chrysin, baicalein, scutellarein, sinensetin and genkwanin by recombinant CYP1A1, CYP1B1 and CYP1A2 enzymes, as well as their antiproliferative activity in MDA-MB-468 human breast adenocarcinoma and MCF-10A normal breast cell lines, were investigated. Baicalein and 6-hydroxyluteolin were the only conversion products of chrysin and scutellarein metabolism by CYP1 family enzymes, respectively, while baicalein itself was not metabolized further. Sinensetin and genkwanin produced a greater number of metabolites and were shown to inhibit strongly in vitro proliferation of MDA-MB-468 cells at submicromolar and micromolar concentrations, respectively, without essentially affecting the viability of MCF-10A cells. Cotreatment of the CYP1 family inhibitor acacetin reversed the antiproliferative activity noticed for the two flavones in MDA-MB-468 cells to 13 and 14 μM respectively. In contrast chrysin, baicalein and scutellarein inhibited proliferation of MDA-MB-468 cells to a lesser extent than sinensetin and genkwanin. The metabolism of genkwanin to apigenin and of chrysin to baicalein was favored by CYP1B1 and CYP1A1, respectively. Taken together the data suggests that CYP1 family enzymes enhance the antiproliferative activity of dietary flavonoids in breast cancer cells, through bioconversion to more active products.

  15. Minimal impact of adjuvant exemestane or tamoxifen treatment on mammographic breast density in postmenopausal breast cancer patients: A Dutch TEAM trial analysis

    NARCIS (Netherlands)

    J.G.H. van Nes; L.V. Beex (Louk); C.M. Seynaeve (Caroline); H. Putter (Hein); A. Sramek (Alexandr); S. Lardenoije (Susanne); M.D.-D.E. Carpentier (Marjolijn Duijm-D.E.); I. Van Rongen (Inge); J.W.R. Nortier (Johan W. R.); H.M. Zonderland (Harmine); C.J.H. van de Velde (Cornelis)

    2015-01-01

    textabstractBackground. Mammographic breast density is one of the strongest independent risk factors for developing breast cancer. We examined the effect of exemestane and tamoxifen on breast density in Dutch postmenopausal early breast cancer patients participating in the Tamoxifen Exemestane

  16. Brachytherapy, diagnostic radiology, mammographic radiology and ophthalmic applicators. An assessment of current and future needs in the UK and the role of NPL

    International Nuclear Information System (INIS)

    Angliss, R.; Bass, G.; Sander, T.

    2001-01-01

    Several UK hospitals were visited by NPL staff to discuss the current practises and future developments in brachytherapy, diagnostic and mammographic radiology and ophthalmic applicators. The results of the discussions are presented here, including NPL's role in each of these areas is discussed. (author)

  17. Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

    International Nuclear Information System (INIS)

    Nothacker, Monika; Duda, Volker; Hahn, Markus; Warm, Mathias; Degenhardt, Friedrich; Madjar, Helmut; Weinbrenner, Susanne; Albert, Ute-Susann

    2009-01-01

    Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and

  18. A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    Selecting optimal features from a large image feature pool remains a major challenge in developing computer-aided detection (CAD) schemes of medical images. The objective of this study is to investigate a new approach to significantly improve efficacy of image feature selection and classifier optimization in developing a CAD scheme of mammographic masses. An image dataset including 1600 regions of interest (ROIs) in which 800 are positive (depicting malignant masses) and 800 are negative (depicting CAD-generated false positive regions) was used in this study. After segmentation of each suspicious lesion by a multilayer topographic region growth algorithm, 271 features were computed in different feature categories including shape, texture, contrast, isodensity, spiculation, local topological features, as well as the features related to the presence and location of fat and calcifications. Besides computing features from the original images, the authors also computed new texture features from the dilated lesion segments. In order to select optimal features from this initial feature pool and build a highly performing classifier, the authors examined and compared four feature selection methods to optimize an artificial neural network (ANN) based classifier, namely: (1) Phased Searching with NEAT in a Time-Scaled Framework, (2) A sequential floating forward selection (SFFS) method, (3) A genetic algorithm (GA), and (4) A sequential forward selection (SFS) method. Performances of the four approaches were assessed using a tenfold cross validation method. Among these four methods, SFFS has highest efficacy, which takes 3%-5% of computational time as compared to GA approach, and yields the highest performance level with the area under a receiver operating characteristic curve (AUC) = 0.864 ± 0.034. The results also demonstrated that except using GA, including the new texture features computed from the dilated mass segments improved the AUC results of the ANNs optimized

  19. Background parenchymal enhancement on breast MRI and mammographic breast density: correlation with tumour characteristics

    International Nuclear Information System (INIS)

    Kim, M.Y.; Choi, N.; Yang, J.-H.; Yoo, Y.B.; Park, K.S.

    2015-01-01

    Aim: To investigate the relationship between mammographic breast density (MGD) and background parenchymal enhancement (BPE) at breast MRI and histopathological features of invasive breast cancers. Materials and methods: A total of 178 women with unilateral invasive breast cancer who preoperatively underwent mammography and breast MRI were included in the study. Two radiologists rated MGD and BPE according to BI-RADS criteria in consensus. The relationship between MGD and BPE was investigated, and compared with histopathological features of invasive breast cancers according to the level of MGD and BPE. Results: At MRI, there is no significant difference in the distribution of MGD and BPE of the contralateral breast in women with invasive breast cancer according to menopausal status (p=0.226, 0.384). Women with high MGD (>50% glandular) were more likely to have oestrogen-receptor (ER)-positive breast cancer (p=0.045) and progesterone receptor (PR)-positive breast cancer (p=0.020). With regard to BPE, PR positivity correlated with moderate or marked BPE with borderline significance (p=0.054). Multivariate logistic regression analyses revealed that women with high MGD were less likely to have triple-negative (i.e., a cancer that is ER negative, PR negative, and human epidermal growth factor receptor type 2 [HER2] negative) breast cancer compared with ER (+)/HER2 (−) cancer (OR=0.231, 95% CI: 0.070, 0.760; p=0.016). No association between the histological tumour characteristics and BPE was observed. Conclusion: In women with invasive breast cancer, high MGD is associated with ER positivity of the invasive breast cancer. However, at MRI, BPE of the contralateral breast seems to be independent of tumour characteristics. -- Highlights: •There is no difference in distribution of MGD and BPE of contralateral breast on MRI. •High MGD is associated with ER positivity of the invasive breast cancer. •BPE of the contralateral breast on MRI is independent of tumor

  20. Interval breast cancers: Absolute and proportional incidence and blinded review in a community mammographic screening program

    Energy Technology Data Exchange (ETDEWEB)

    Carbonaro, Luca A., E-mail: luca.carbonaro@gmail.com [Unità di Radiologia, IRCCS Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese (Mi) 20097 (Italy); Azzarone, Antonio [Servizio di Radiologia, Azienda Ospedaliera Circolo di Melegnano, Via Pandina 1, Vizzolo Predabissi (Mi) 20070 (Italy); Paskeh, Bijan Babaei [Unità di Radiologia, IRCCS Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese (Mi) 20097 (Italy); Brambilla, Giorgio [Dipartimento di Radiologia, IRCCS Istituto Clinico Humanitas, Via Manzoni 56, Rozzano (Mi) 20089 (Italy); Brunelli, Silvia [Centro di Prevenzione Senologica, ULSS 20, Piazza Lambranzi, Verona 37034 (Italy); Calori, Anna [Servizio di Radiologia, Azienda Ospedaliera Circolo di Melegnano, Via Pandina 1, Vizzolo Predabissi (Mi) 20070 (Italy); Caumo, Francesca [Centro di Prevenzione Senologica, ULSS 20, Piazza Lambranzi, Verona 37034 (Italy); Malerba, Paolo [Dipartimento di Radiologia, IRCCS Istituto Clinico Humanitas, Via Manzoni 56, Rozzano (Mi) 20089 (Italy); Menicagli, Laura [Unità di Radiologia, IRCCS Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese (Mi) 20097 (Italy); Sconfienza, Luca M. [Unità di Radiologia, IRCCS Policlinico San Donato, Piazza E. Malan 2, San Donato Milanese (Mi) 20097 (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Milano (Italy); Vadalà, Giuseppe [Servizio di Radiologia, Azienda Ospedaliera Circolo di Melegnano, Via Pandina 1, Vizzolo Predabissi (Mi) 20070 (Italy); Brambilla, Gelma; Fantini, Luigi [Servizio di Medicina Preventiva delle Comunità, ASL Milano 2, Via Friuli 2, Lacchiarella (Mi) 20084 (Italy); Ciatto, Stefano [Screening Program, ULSS 16, Padova (Italy); and others

    2014-02-15

    Purpose: To evaluate the performance of the first years since the beginning of a mammographic population-based screening program. Materials and methods: Women aged 49–69 were invited biennially for two-view film-screen mammography and double reading without arbitration was performed. Interval cancers (ICs) from 2001 to 2006 were identified using screening archives, local pathology archives, and hospital discharge records. The proportional incidence of IC was determined considering breast cancers expected without screening. Three offsite radiologists experienced in breast cancer screening blindly evaluated mammograms prior to diagnosis, randomly mixed with negative mammograms (1:2 ratio). Cases unrecalled at review were considered as true ICs, those recalled by only one reviewer as minimal signs, and those recalled by two or three reviewers as missed cancers. T and N stage of the reviewed ICs were evaluated and compared. Results: A total of 86,276 first level mammograms were performed. Mean recall rate was 6.8% at first and 4.6% at repeat screening. We had 476 screen-detected cancers and 145 ICs (10 of them ductal carcinomas in situ). Absolute incidence was 17 per 10,000 screening examinations. Invasive proportional incidence was 19% (44/234) in the first year, 39% (91/234) in the second year, and 29% (135/468) in the two-year interval. Of 145 ICs, 130 (90%) were reviewed mixed with 287 negative controls: 55% (71/130) resulted to be true ICs, 24% (31/130) minimal signs, and 22% (28/130) missed cancers. The rate of ICs diagnosed in the first year interval was 21% (15/71) for true ICs, 46% (13/28) for missed cancers, and 39% (12/31) for minimal signs, with a significant difference of true ICs rate compared to missed cancers rate (p = 0.012). A higher rate of T3 and T4 stages was found for missed cancers (18%, 5/28) compared to minimal signs (6%, 2/31) or true ICs (8%, 6/71), while the rate of N2 and N3 stage for both minimal signs (19%, 6/31) or missed cancers (25

  1. Interval breast cancers: Absolute and proportional incidence and blinded review in a community mammographic screening program

    International Nuclear Information System (INIS)

    Carbonaro, Luca A.; Azzarone, Antonio; Paskeh, Bijan Babaei; Brambilla, Giorgio; Brunelli, Silvia; Calori, Anna; Caumo, Francesca; Malerba, Paolo; Menicagli, Laura; Sconfienza, Luca M.; Vadalà, Giuseppe; Brambilla, Gelma; Fantini, Luigi; Ciatto, Stefano

    2014-01-01

    Purpose: To evaluate the performance of the first years since the beginning of a mammographic population-based screening program. Materials and methods: Women aged 49–69 were invited biennially for two-view film-screen mammography and double reading without arbitration was performed. Interval cancers (ICs) from 2001 to 2006 were identified using screening archives, local pathology archives, and hospital discharge records. The proportional incidence of IC was determined considering breast cancers expected without screening. Three offsite radiologists experienced in breast cancer screening blindly evaluated mammograms prior to diagnosis, randomly mixed with negative mammograms (1:2 ratio). Cases unrecalled at review were considered as true ICs, those recalled by only one reviewer as minimal signs, and those recalled by two or three reviewers as missed cancers. T and N stage of the reviewed ICs were evaluated and compared. Results: A total of 86,276 first level mammograms were performed. Mean recall rate was 6.8% at first and 4.6% at repeat screening. We had 476 screen-detected cancers and 145 ICs (10 of them ductal carcinomas in situ). Absolute incidence was 17 per 10,000 screening examinations. Invasive proportional incidence was 19% (44/234) in the first year, 39% (91/234) in the second year, and 29% (135/468) in the two-year interval. Of 145 ICs, 130 (90%) were reviewed mixed with 287 negative controls: 55% (71/130) resulted to be true ICs, 24% (31/130) minimal signs, and 22% (28/130) missed cancers. The rate of ICs diagnosed in the first year interval was 21% (15/71) for true ICs, 46% (13/28) for missed cancers, and 39% (12/31) for minimal signs, with a significant difference of true ICs rate compared to missed cancers rate (p = 0.012). A higher rate of T3 and T4 stages was found for missed cancers (18%, 5/28) compared to minimal signs (6%, 2/31) or true ICs (8%, 6/71), while the rate of N2 and N3 stage for both minimal signs (19%, 6/31) or missed cancers (25

  2. A self-directed learning intervention for radiographers rating mammographic breast density

    International Nuclear Information System (INIS)

    Ekpo, E.U.; Hogg, P.; Wasike, E.; McEntee, M.F.

    2017-01-01

    Purpose: Subjective methods of mammographic breast density (MBD) assessment are prone to inter-reader variability. This work aims to assess the impact of a short self-directed, experiential learning intervention on radiographers' reproducibility of MBD assessment. Method: The study used two sets of images (test and learning intervention) containing left craniocaudal and left mediolateral oblique views. The test set had MBD ratings from Volpara™ and radiologists using the fourth edition Breast Imaging and Data Systems (BI-RADS ® ). Seven radiographers rated the MBD of the test set before and after a self-directed learning intervention using the percentage descriptors in the fourth edition BI-RADS ® Atlas. The inter-reader agreement, the agreement between radiographers and Volpara™ as well as radiologists, was assessed using a Weighted Kappa (κ w ). Results: Overall, radiographers' inter-reader agreement (κ w ) was substantial (0.79; 95% CI: 0.70–0.87) before the intervention and almost perfect (0.84; 95% CI: 0.77–0.90) after the intervention. Before the intervention, radiographers demonstrated fair agreement with radiologists (0.24; 95% CI: −0.46–0.61) and Volpara™ (0.24; 95% CI: −0.41–0.59). A fair but slightly improved agreement was also observed between radiographers and radiologists (0.31; 95% CI: −0.33–0.64) as well as Volpara™ (0.28; 95% CI: −0.34–0.61) after the intervention. Conclusion: Findings demonstrate that a short duration self-directed, experiential learning intervention reduces inter-reader differences in MBD classification, but has a negligible impact on improving the agreement between inexperienced and expert readers. - Highlights: • Radiographers' MBD rating show fair agreement with radiologists and Volpara™. • Experiential learning intervention improved reproducibility of MBD classification. • Enhanced MBD rating training may be required to develop a standard fit for practice.

  3. Mammographic Density Phenotypes and Risk of Breast Cancer: A Meta-analysis

    Science.gov (United States)

    Graff, Rebecca E.; Ursin, Giske; dos Santos Silva, Isabel; McCormack, Valerie; Baglietto, Laura; Vachon, Celine; Bakker, Marije F.; Giles, Graham G.; Chia, Kee Seng; Czene, Kamila; Eriksson, Louise; Hall, Per; Hartman, Mikael; Warren, Ruth M. L.; Hislop, Greg; Chiarelli, Anna M.; Hopper, John L.; Krishnan, Kavitha; Li, Jingmei; Li, Qing; Pagano, Ian; Rosner, Bernard A.; Wong, Chia Siong; Scott, Christopher; Stone, Jennifer; Maskarinec, Gertraud; Boyd, Norman F.; van Gils, Carla H.

    2014-01-01

    Background Fibroglandular breast tissue appears dense on mammogram, whereas fat appears nondense. It is unclear whether absolute or percentage dense area more strongly predicts breast cancer risk and whether absolute nondense area is independently associated with risk. Methods We conducted a meta-analysis of 13 case–control studies providing results from logistic regressions for associations between one standard deviation (SD) increments in mammographic density phenotypes and breast cancer risk. We used random-effects models to calculate pooled odds ratios and 95% confidence intervals (CIs). All tests were two-sided with P less than .05 considered to be statistically significant. Results Among premenopausal women (n = 1776 case patients; n = 2834 control subjects), summary odds ratios were 1.37 (95% CI = 1.29 to 1.47) for absolute dense area, 0.78 (95% CI = 0.71 to 0.86) for absolute nondense area, and 1.52 (95% CI = 1.39 to 1.66) for percentage dense area when pooling estimates adjusted for age, body mass index, and parity. Corresponding odds ratios among postmenopausal women (n = 6643 case patients; n = 11187 control subjects) were 1.38 (95% CI = 1.31 to 1.44), 0.79 (95% CI = 0.73 to 0.85), and 1.53 (95% CI = 1.44 to 1.64). After additional adjustment for absolute dense area, associations between absolute nondense area and breast cancer became attenuated or null in several studies and summary odds ratios became 0.82 (95% CI = 0.71 to 0.94; P heterogeneity = .02) for premenopausal and 0.85 (95% CI = 0.75 to 0.96; P heterogeneity women. Conclusions The results suggest that percentage dense area is a stronger breast cancer risk factor than absolute dense area. Absolute nondense area was inversely associated with breast cancer risk, but it is unclear whether the association is independent of absolute dense area. PMID:24816206

  4. Geneva cocktail for cytochrome p450 and P-glycoprotein activity assessment using dried blood spots.

    Science.gov (United States)

    Bosilkovska, M; Samer, C F; Déglon, J; Rebsamen, M; Staub, C; Dayer, P; Walder, B; Desmeules, J A; Daali, Y

    2014-09-01

    The suitability of the capillary dried blood spot (DBS) sampling method was assessed for simultaneous phenotyping of cytochrome P450 (CYP) enzymes and P-glycoprotein (P-gp) using a cocktail approach. Ten volunteers received an oral cocktail capsule containing low doses of the probes bupropion (CYP2B6), flurbiprofen (CYP2C9), omeprazole (CYP2C19), dextromethorphan (CYP2D6), midazolam (CYP3A), and fexofenadine (P-gp) with coffee/Coke (CYP1A2) on four occasions. They received the cocktail alone (session 1), and with the CYP inhibitors fluvoxamine and voriconazole (session 2) and quinidine (session 3). In session 4, subjects received the cocktail after a 7-day pretreatment with the inducer rifampicin. The concentrations of probes/metabolites were determined in DBS and plasma using a single liquid chromatography-tandem mass spectrometry method. The pharmacokinetic profiles of the drugs were comparable in DBS and plasma. Important modulation of CYP and P-gp activities was observed in the presence of inhibitors and the inducer. Minimally invasive one- and three-point (at 2, 3, and 6 h) DBS-sampling methods were found to reliably reflect CYP and P-gp activities at each session.

  5. Influences of Realgar-Indigo naturalis, A Traditional Chinese Medicine Formula, on the Main CYP450 Activities in Rats Using a Cocktail Method

    Directory of Open Access Journals (Sweden)

    Huan-Hua Xu

    2017-01-01

    Full Text Available The purpose of this work was to study the influences of Realgar-Indigo naturalis (RIF and its principal element realgar on 4 main cytochrome P450 enzymes activities in rats. A simple and efficient cocktail method was developed to detect the four probe drugs simultaneously. In this study, Wistar rats were administered intragastric RIF and realgar for 14 days; mixed probe drugs were injected into rats by caudal vein. Through analyzing the pharmacokinetic parameter of mixed probe drugs in rats, we can calculate the CYPs activities. The results showed that RIF could inhibit CYP1A2 enzyme activity and induce CYP2C11 enzyme activity significantly. Interestingly, in realgar high dosage group, CYP3A1/2 enzyme activity was inhibited significantly, and different dosage of realgar manifested a good dose-dependent manner. The RIF results indicated that drug coadministrated with RIF may need to be paid attention in relation to drug-drug interactions (DDIs. Realgar, a toxic traditional Chinese medicine (TCM, does have curative effect on acute promyelocytic leukemia (APL. Its toxicity studies should be focused on. We found that, in realgar high dosage group, CYP3A1/2 enzymes activity was inhibited. This phenomenon may explain its potential toxicity mechanism.

  6. The influence of mammographic X-ray spectra on absorbed energy distribution in breast: Monte Carlo simulation studies

    International Nuclear Information System (INIS)

    Delis, H.; Spyrou, G.; Tzanakos, G.; Panayiotakis, G.

    2005-01-01

    A mathematical model, based on Monte Carlo simulation, is proposed for deriving absorbed energy and dose distribution in mammography utilizing a mathematical water-like phantom. The model was validated for its accuracy against experimental and published data. The main factor discriminating absorbed energy distribution characteristics among different mammographic techniques was considered the X-ray spectrum. The absorbed energy distribution inside the phantom was investigated via percentage depth dose and isodose curves. The influence of the factors affecting X-ray spectrum (tube voltage, anode material, filter material and thickness) on absorbed energy distribution was examined. The hardness of the beam, due to increase of tube voltage or filtration, was found to be the major factor affecting absorbed energy distribution inside the phantom. In general, Mo and W anode systems demonstrated superior dosimetric characteristics against those of W-Mo or Rh. The model presented can be used for estimating absolute and relative breast dose values and their spatial distributions

  7. Progress of the correlation study between mammographic appearances and expression of p53, Ki-67 in patients with breast cancer

    International Nuclear Information System (INIS)

    Liu Jie; Liu Peifang

    2013-01-01

    Breast cancer is one of the most common female malignant tumors. The occurrence and development of breast cancer are often accompanied by abnormal gene expression. It has been well accepted that p53, Ki -67 are the commonly used biological indicators for clinical endocrine therapy and prognosis prediction. The oncogene expression reflects the malignant biological behavior of breast cancer from different perspectives. Those aggressive behaviors cause a variety of changes in histopathology and thus in imaging. Therefore, the imaging features of breast cancer may indirectly demonstrate the status of p53, Ki-67. Until now, because of its facility, low cost and high accuracy, mammography is still the preferred method in breast cancer screening and diagnosis. The relationship of mammographic appearances and gene expression in patients with breast cancer has potential clinical value in preoperative evaluation and planning of non-surgical treatment for those who are not able to perform immunohistochemistry. (authors)

  8. Insulin-like growth factor-I (IGF-1), IGF-binding protein-3 (IGFBP-3) and mammographic features.

    Science.gov (United States)

    Izzo, L; Meggiorini, M L; Nofroni, I; Pala, A; De Felice, C; Meloni, P; Simari, T; Izzo, S; Pugliese, F; Impara, L; Merlini, G; Di Cello, P; Cipolla, V; Forcione, A R; Paliotta, A; Domenici, L; Bolognese, A

    2012-05-01

    The IGF system has recently been shown to play an important role in the regulation of breast tumor cell proliferation. However, also breast density is currently considered as the strongest breast cancer risk factor. It is not yet clear whether these factors are interrelated and if and how they are influenced by menopausal status. The purpose of this study was to examine the possible effects of IGF-1 and IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density stratified by menopausal status. A group of 341 Italian women were interviewed to collect the following data: family history of breast cancer, reproductive and menstrual factors, breast biopsies, previous administration of hormonal contraceptive therapy, hormone replacement therapy (HRT) in menopause and lifestyle information. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels. IGF-1/ IGFBP-3 molar ratio was then calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). Student's t-test was employed to assess the association between breast density and plasma level of IGF-1, IGFBP-3 and molar ratio. To assess if this relationship was similar in subgroups of pre- and postmenopausal women, the study population was stratified by menopausal status and Student's t-test was performed. Finally, multivariate analysis was employed to evaluate if there were confounding factors that might influence the relationship between growth factors and breast density. The analysis of the relationship between mammographic density and plasma level of IGF-1, IGFBP-3 and IGF-1/ IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group (IGF-1: 109.6 versus 96.6 ng/ml; p= 0.001 and molar ratio 29.4 versus 25.5 ng/ml; p= 0.001) whereas IGFBP-3 showed similar values in both groups (DB and NDB). Analysis of plasma level of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio

  9. Characterization of mammographic findings radiological studies, in radiology service Hospital Doctor Rafael Angel Calderon Guardia during the year 2012

    International Nuclear Information System (INIS)

    Ugalde Gatjens, Mauricio

    2013-01-01

    The radiological findings are determined in reading mammography studies between the months of May and June 2012 in the radiology service of Hospital Calderon Guardia. The association of pathologies is determined between breast pathology, age group and sex. A control allowing identification of geographic areas with higher reference is established for realization of mammograms. The pathologies resulting from the reading of mammographic studies are quantified and classified. The patients have presented 42% of risk factors with the potential predisposition to develop breast cancer. Mammography applications have been coming in 22% of Montes de Oca EBAIS and Curridabat, being presented in most lesions in women between 45 and 74 years old. Mammograms analyzed are classified as BIRADS 2 and to a lesser extent as BIRADS 0 [es

  10. Tumour characteristics and survival in patients with invasive interval breast cancer classified according to mammographic findings at the latest screening

    DEFF Research Database (Denmark)

    Vitak, B; Olsen, K E; Månson, J C

    1999-01-01

    with invasive interval cancer detected from May 1978 to August 1995 (n = 544). The tumours were evaluated with regard to age, radiological category, interval between the latest screen and diagnosis and tumour characteristics at the time of diagnosis. We investigated possible relationships between the survival...... screen and diagnosis were not genuine predictors of the prognosis in patients with invasive interval breast cancer. No certain prognostic difference existed between true interval cancers and overlooked or misinterpreted interval breast cancers, despite higher proportions of grade-I tumours, ER positive......The aim of this study was to investigate whether different mammographic categories of interval cancer classified according to findings at the latest screening are associated with different distributions of prognostic factors or with different survival rates. The series consisted of all patients...

  11. Sleep patterns, sleep disorders and mammographic density in spanish women: The DDM-Spain/Var-DDM study.

    Science.gov (United States)

    Pedraza-Flechas, Ana María; Lope, Virginia; Moreo, Pilar; Ascunce, Nieves; Miranda-García, Josefa; Vidal, Carmen; Sánchez-Contador, Carmen; Santamariña, Carmen; Pedraz-Pingarrón, Carmen; Llobet, Rafael; Aragonés, Nuria; Salas-Trejo, Dolores; Pollán, Marina; Pérez-Gómez, Beatriz

    2017-05-01

    We explored the relationship between sleep patterns and sleep disorders and mammographic density (MD), a marker of breast cancer risk. Participants in the DDM-Spain/var-DDM study, which included 2878 middle-aged Spanish women, were interviewed via telephone and asked questions on sleep characteristics. Two radiologists assessed MD in their left craneo-caudal mammogram, assisted by a validated semiautomatic-computer tool (DM-scan). We used log-transformed percentage MD as the dependent variable and fitted mixed linear regression models, including known confounding variables. Our results showed that neither sleeping patterns nor sleep disorders were associated with MD. However, women with frequent changes in their bedtime due to anxiety or depression had higher MD (e β :1.53;95%CI:1.04-2.26). Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Computerized analysis of mammographic parenchymal patterns for assessing breast cancer risk: Effect of ROI size and location

    International Nuclear Information System (INIS)

    Li Hui; Giger, Maryellen L.; Huo Zhimin; Olopade, Olufunmilayo I.; Lan Li; Weber, Barbara L.; Bonta, Ioana

    2004-01-01

    The long-term goal of our research is to develop computerized radiographic markers for assessing breast density and parenchymal patterns that may be used together with clinical measures for determining the risk of breast cancer and assessing the response to preventive treatment. In our earlier studies, we found that women at high risk tended to have dense breasts with mammographic patterns that were coarse and low in contrast. With our method, computerized texture analysis is performed on a region of interest (ROI) within the mammographic image. In our current study, we investigate the effect of ROI size and ROI location on the computerized texture features obtained from 90 subjects (30 BRCA1/BRCA2 gene-mutation carriers and 60 age-matched women deemed to be at low risk for breast cancer). Mammograms were digitized at 0.1 mm pixel size and various ROI sizes were extracted from different breast regions in the craniocaudal (CC) view. Seventeen features, which characterize the density and texture of the parenchymal patterns, were extracted from the ROIs on these digitized mammograms. Stepwise feature selection and linear discriminant analysis were applied to identify features that differentiate between the low-risk women and the BRCA1/BRCA2 gene-mutation carriers. ROC analysis was used to assess the performance of the features in the task of distinguishing between these two groups. Our results show that there was a statistically significant decrease in the performance of the computerized texture features, as the ROI location was varied from the central region behind the nipple. However, we failed to show a statistically significant decrease in the performance of the computerized texture features with decreasing ROI size for the range studied

  13. Results of breast conserving therapy for early breast cancer and the role of mammographic follow-up

    International Nuclear Information System (INIS)

    Grosse, Antje; Schreer, Ingrid; Frischbier, Hans-Joachim; Maass, Heinrich; Loening, Thomas; Bahnsen, Jens

    1997-01-01

    Purpose: The following article is a review of 23 years of breast-conserving therapy in our hospital. This study was performed to assess and improve the follow-up care of women with early breast cancer and to evaluate whether or not biannual mammogram is useful. Methods and Materials: Between 1972 and December 1995, 3072 women with pathological size pT1 and pT2 breast cancer were treated with conservative surgery and radiation therapy. Eighty-five patients developed a recurrence in the treated breast as the first site of failure, 12 of which had positive axillary nodes. In the following patient study, those with an noninvasive recurrence were excluded. A retrospective assessment of the entire mammographic course was made, starting with the mammogram at the time of original diagnosis to the mammogram of the recurrence. Results: In our study group the probability for local failure ranged from 1 to 2% per year. At 5 and 10 years the actuarial rates were 5 and 10%. The median time to recurrence was 41 months (range 8-161). Twenty-six (31%) recurrences were detected by mammography alone, 10 (12%) by clinical examination only, and 35 (41%) by both methods. For the patients with an ipsilateral recurrence, the overall actuarial 5- and 10-year survival after treatment was 87 and 70%, respectively. The 5-year actuarial rate of survival from salvage mastectomy was 61%. Conclusion: Considering the high percentage of recurrences detectable by mammography and the possibility of detection within a short-term interval, we think biannual mammographic follow-up is appropriate for the first years following breast-conserving therapy

  14. Mammographic casting-type calcification associated with small screen-detected invasive breast cancers: is this a reliable prognostic indicator?

    International Nuclear Information System (INIS)

    Peacock, C.; Given-Wilson, R.M.; Duffy, S.W.

    2004-01-01

    AIM: The aim of the present study was to establish whether mammographic casting-type calcification associated with small screen-detected invasive breast cancers is a reliable prognostic indicator. METHODS AND MATERIALS: We retrospectively identified 50 consecutive women diagnosed with an invasive cancer less than 15 mm who showed associated casting calcification on their screening mammograms. Controls were identified that showed no microcalcification and were matched for tumour size, histological type and lymph node status. A minimum of 5 years follow-up was obtained, noting recurrence and outcome. Conditional and unconditional logistic regression, depending on the outcome variable, were used to analyse the data, taking the matched design into account in both cases. Where small numbers prohibited the use of logistic regression, Fisher's exact test was used. RESULTS: Five deaths from breast cancer occurred out of the 50 cases, of which three were lymph node positive, two were lymph node negative and none were grade 3. None of the 78 control cases died from breast cancer. The difference in breast cancer death rates was significant by Fisher's exact test (p=0.02). Risk of recurrence was also significantly increased in the casting cases (OR=3.55, 95% CI 1.02-12.33, p=0.046). CONCLUSION: Although the overall outcome for small screen-detected breast cancers is good, our study suggests that casting calcification is a poorer prognostic factor. The advantage of a mammographic feature as an independent prognostic indicator lies in early identification of high-risk patients, allowing optimization of management

  15. Evaluation Of Digital Unsharp-Mask Filtering For The Detection Of Subtle Mammographic Microcalcifications

    Science.gov (United States)

    Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.

    1986-06-01

    We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted

  16. Image simulation and a model of noise power spectra across a range of mammographic beam qualities

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair, E-mail: alistairmackenzie@nhs.net; Dance, David R.; Young, Kenneth C. [National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Diaz, Oliver [Centre for Vision, Speech and Signal Processing, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom and Computer Vision and Robotics Research Institute, University of Girona, Girona 17071 (Spain)

    2014-12-15

    Purpose: The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Methods: Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. Results: The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise

  17. Otimização de imagens mamográficas Optimization of mammographic images

    Directory of Open Access Journals (Sweden)

    Diana Rodrigues de Pina

    2006-10-01

    Full Text Available OBJETIVO: Este trabalho tem como objetivo a otimização de imagens mamográficas, com consideráveis reduções de doses. MATERIAIS E MÉTODOS: Neste estudo o feixe de raios-X foi calibrado para cada tensão (kVp, de modo a determinar a melhor combinação de kVp e mAs que irá proporcionar uma densidade ótica (DO em torno de 1.0 acima da base mais véu do filme utilizado. RESULTADOS: Serão discutidas questões sobre os métodos empregados para a seleção de parâmetros de exposição do feixe de raios-X, seleção da melhor imagem utilizando o método de avaliação gradativa visual, comparações entre as doses e carga do tubo (kVp × mAs proporcionadas pelas técnicas determinadas neste estudo e pelas utilizadas na rotina clínica do Serviço de Diagnóstico por Imagem do Hospital das Clínicas da Faculdade de Medicina de Botucatu. Neste estudo foram obtidas imagens radiográficas de mama de excelente qualidade, com redução de dose e carga de tubo, respectivamente, de 36,8% e 46,2%, quando comparadas com a técnica utilizada pela rotina clínica da instituição. CONCLUSÃO: Esta pesquisa vem contribuir com a otimização da relação risco-benefício para o paciente e custo-benefício para a instituição.OBJECTIVE: The aim of this study is the optimization of mammographic images with a considerable radiation dose reduction. MATERIALS AND METHODS: In the present study the X-ray beam was calibrated for each tension (kVp, aiming at determining the best combination between kVp and mAs, resulting in optical densities of about 1.0 above the base-plus-fog density. RESULTS: This study will bring into question the methods for X-ray beam calibration, the choice of the best image by means of visual grading analysis, comparisons between doses and tube load (kVp × mAs delivered by the techniques described in this study and by those adopted in the clinical routine at Service of Diagnostic Imaging of Faculdade de Medicina de Botucatu Clinics

  18. Influences of Oldenlandia diffusa on the CYP450 Activities in Rats Using a Cocktail Method by UHPLC-MS/MS

    Directory of Open Access Journals (Sweden)

    Yiping Lin

    2018-01-01

    Full Text Available Oldenlandia diffusa has been used to treat various cancers. Cytochrome P450, a drug metabolic enzyme, might be influenced by herbal medicine. Currently, the problem that remains is the effective treatment in drug-drug interaction situation. Potential influences of Oldenlandia diffusa were elucidated on the CYP450 activities in rats using a cocktail method. Blood samples were precipitated by acetonitrile. Quantitative determination of target test object was done by ultra-performance liquid chromatography tandem mass spectrometry detection. Influences of oldenlandia diffusa on the activities of five CYP450 subtypes in rats were evaluated by five specific probe drugs (phenacetin for CYP1A2, omeprazole for CYP2C19, tolbutamide for CYP2C9, metoprolol for CYP2D6, and midazolam for CYP3A4 according to the pharmacokinetic parameters changes. No statistically significant difference (P>0.05 in pharmacokinetic behaviors can be observed in the five probe drugs. There is a potential guidance on clinical drug combination with Oldenlandia diffusa. Oldenlandia diffusa in compound preparation showed well security.

  19. Changes in cytochrome P450 gene expression and enzyme activity induced by xenobiotics in rabbits in vivo and in vitro

    Directory of Open Access Journals (Sweden)

    Orsolya Palócz

    2017-06-01

    Full Text Available As considerable inter-species differences exist in xenobiotic metabolism, developing new pharmaceutical therapies for use in different species is fraught with difficulties. For this reason, very few medicines have been registered for use in rabbits, despite their importance in inter alia meat and fur production. We have developed a rapid and sensitive screening system for drug safety in rabbits based on cytochrome P450 enzyme assays, specifically CYP1A1, CYP1A2 and CYP3A6, employing an adaptation of the luciferin-based clinical assay currently used in human drug screening. Short-term (4-h cultured rabbit primary hepatocytes were treated with a cytochrome inducer (phenobarbital and 2 inhibitors (alpha-naphthoflavone and ketoconazole. In parallel, and to provide verification, New Zealand white rabbits were dosed with 80 mg/kg phenobarbital or 40 mg/kg ketoconazole for 3 d. Ketoconazole significantly increased CYP3A6 gene expression and decreased CYP3A6 activity both in vitro and in vivo. CYP1A1 activity was decreased by ketoconazole in vitro and increased in vivo. This is the first report of the inducer effect of ketoconazole on rabbit cytochrome isoenzymes in vivo. Our data support the use of a luciferin-based assay in short-term primary hepatocytes as an appropriate tool for xenobiotic metabolism assays and short-term toxicity testing in rabbits.

  20. GABAA receptor activity modulating piperine analogs: In vitro metabolic stability, metabolite identification, CYP450 reaction phenotyping, and protein binding.

    Science.gov (United States)

    Zabela, Volha; Hettich, Timm; Schlotterbeck, Götz; Wimmer, Laurin; Mihovilovic, Marko D; Guillet, Fabrice; Bouaita, Belkacem; Shevchenko, Bénédicte; Hamburger, Matthias; Oufir, Mouhssin

    2018-01-01

    In a screening of natural products for allosteric modulators of GABA A receptors (γ-aminobutyric acid type A receptor), piperine was identified as a compound targeting a benzodiazepine-independent binding site. Given that piperine is also an activator of TRPV1 (transient receptor potential vanilloid type 1) receptors involved in pain signaling and thermoregulation, a series of piperine analogs were prepared in several cycles of structural optimization, with the aim of separating GABA A and TRPV1 activating properties. We here investigated the metabolism of piperine and selected analogs in view of further cycles of lead optimization. Metabolic stability of the compounds was evaluated by incubation with pooled human liver microsomes, and metabolites were analyzed by UHPLC-Q-TOF-MS. CYP450 isoenzymes involved in metabolism of compounds were identified by reaction phenotyping with Silensomes™. Unbound fraction in whole blood was determined by rapid equilibrium dialysis. Piperine was the metabolically most stable compound. Aliphatic hydroxylation, and N- and O-dealkylation were the major routes of oxidative metabolism. Piperine was exclusively metabolized by CYP1A2, whereas CYP2C9 contributed significantly in the oxidative metabolism of all analogs. Extensive binding to blood constituents was observed for all compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Breast nodules detection in images of ultrasonographic and mammographic simulators; Deteccao de nodulos mamarios em imagens de simuladores ultrassonografico e mamografico

    Energy Technology Data Exchange (ETDEWEB)

    Marcomini, Karem D.; Schiabel, Homero, E-mail: karem.dm@usp.br [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Eletrica; Carneiro, Antonio Adilton O. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2013-08-15

    Due to the high incidence rate of breast cancer in women, many procedures have been developed to assist in the diagnosis and early detection. Mammography and ultrasonography stand out as the main breast imaging techniques. In this context, the schemes of computer-aided diagnosis have provided to the specialist a more accurate and reliable second opinion by minimizing the visual subjectivity inter-observer. Thus, we propose the application of an automated method of segmentation, through the neural network SOM, to provide accurate information regarding the border of the lesion. The tests were employed in 100 mammographic images and 70 sonographic, both cases obtained by simulation. In order to verify the accuracy of the boundaries demarcated by the automatic detector, quantitative measurements were extracted to compare these images with the manually delineated by an experienced radiologist. The proposed technique presented high accuracy and sensitivity, and low error rate in correctly representing the mammographic and sonographic findings. (author)

  2. Mammographic evaluation of suspicious malignant lesions based on ACR(American College of Radiology) breast imaging reporting and data system(BI-RADS)

    International Nuclear Information System (INIS)

    Lee, Jei Hee; Oh, Ki Keun; Chang, So Yong; Kim, Eun Kyung; Kim, Mi Hye

    1999-01-01

    The purpose of this study was to assess the mammographic features and pathologic outcome of category 4 lesions using the Breast Imaging Reporting and Data System(BI-RADS), and to evaluate the significance of final assessment categories. Using BI-RADS, the interpretations of 8,134 mammograms acquired between January 1997 and May 1998 were categorized. From among 161 lesions categorized as '4' ('suspicious abnormality') and pathologically confirmed by surgery or biopsy, we analysed 113, found in 66 patients. The pathologic outcome of these 113 lesions was as follows:infiltrating ductal carcinoma, 17.7%(20/113); DCIS(ductal carcinoma in sitv), 8.0%(9/113); ADH(atypical ductal hyperplasia), 5.3%(6/113); DEH(ductal epithelial hyperplasia), 1.8%(2/113); ductectasia, 0.9%(1/113), FCD(fibrocystic change), 27.4%(31/113); firoadenoma, 7.1%(8/113); stromal fibrosis, 9.7%(11/113); normal parenchyma, 7.1%(8/113); other pathology, 15.0%(17/113). The most frequent mammographic features of BI-RADS category 4 lesions were irregular mass shape(41.2%), spiculated mass margin(52.3%), amorphous calcification(47.3%) and clustered calcification distribution(37.1%). Because category 4 lesions account for about 25.7% of all breast malignancies, mammographic lesions in this category ('suspicious abnormality') should be considered for supplementary study and breast biopsy rather than short-term follow-up. Initial pathologic findings can thus be confirmed

  3. Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S. R.; Bisogni, M. G.; Delogu, P.; Fantacci, M. E.; Paternoster, G.; Rosso, V.; Stefanini, A. [Str. Dip. di Matematica e Fisica dell' Universita di Sassari, Via Vienna 2, I-07100, Sassari (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy)

    2009-04-15

    The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

  4. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  5. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  6. Efficiency of Lu2SiO5:Ce (LSO) powder phosphor as X-ray to light converter under mammographic imaging conditions

    International Nuclear Information System (INIS)

    David, S.; Michail, C.; Valais, I.; Nikolopoulos, D.; Liaparinos, P.; Kalivas, N.; Kalatzis, I.; Toutountzis, A.; Efthimiou, N.; Loudos, G.; Sianoudis, I.; Cavouras, D.; Dimitropoulos, N.; Nomicos, C.D.; Kandarakis, I.; Panayiotakis, G.S.

    2007-01-01

    The aim of the present study was to examine the light emission efficiency of Lu 2 SiO 5 :Ce (LSO) powder scintillator under X-ray mammographic imaging conditions. Powder LSO scintillator has never been used in X-ray imaging. For the purposes of the present study, a 25 mg/cm 2 thick scintillating screen was prepared in our laboratory, by sedimentation of Lu 2 SiO 5 :Ce powder. Absolute luminescence efficiency measurements were performed within the range of X-ray tube voltages (22-49 kVp) used in mammographic applications. Parameters related to X-ray detection, i.e. the energy absorption efficiency (EAE) and the quantum detection efficiency (QDE) were calculated. A theoretical model, describing radiation and light transfer, was employed to fit experimental data and to estimate values of the intrinsic conversion efficiency and the light attenuation coefficients of the screen. The spectral compatibility of the LSO powder scintillator to mammographic X-ray films and to various electronic optical detectors was determined by performing light emission spectrum measurements and by taking into account the spectral sensitivity of the optical detectors. Results in the voltage range used in mammography showed that Lu 2 SiO 5 :Ce powder scintillator has approximately 10% higher values of QDE and 4.5% higher values of EAE than Gd 2 O 2 S:Tb

  7. A Biomedical Investigation of the Hepatoprotective Effect of Radix salviae miltiorrhizae and Network Pharmacology-Based Prediction of the Active Compounds and Molecular Targets

    Directory of Open Access Journals (Sweden)

    Ming Hong

    2017-03-01

    Full Text Available Radix salviae miltiorrhizae (Danshen in Chinese, a classic traditional Chinese medicine (TCM herb, has been used for centuries to treat liver diseases. In this study, the preventive and curative potential of Danshen aqueous extract on acute/chronic alcoholic liver disease (ALD and non-alcoholic fatty liver disease (NAFLD was studied. The in vivo results indicated that Danshen could alleviate hepatic inflammation, fatty degeneration, and haptic fibrogenesis in ALD and NAFLD models. In the aspect of mechanism of action, the significant reduction in MDA levels in both ALD and NAFLD models implies the decreased levels of oxidative stress by Danshen. However, Danshen treatment could not activate the internal enzymatic antioxidant system in ALD and NAFLD models. To further explore the hepatoprotective mechanism of Danshen, an in silico-based network pharmacology approach was employed in the present study. The pharmacological network analysis result revealed that six potential active ingredients such as tanshinone iia, salvianolic acid b, and Danshensu may contribute to the hepatoprotective effects of Danshen on ALD and NAFLD. The action mechanism may relate with regulating the intracellular molecular targets such as PPARα, CYP1A2, and MMP2 for regulation of lipid metabolism, antioxidant and anti-fibrogenesis by these potential active ingredients. Our studies suggest that the combination of network pharmacology strategy with in vivo experimental study may provide a forceful tool for exploring the mechanism of action of traditional Chinese medicine (TCM herb and developing novel bioactive ingredients.

  8. External validation of a publicly available computer assisted diagnostic tool for mammographic mass lesions with two high prevalence research datasets.

    Science.gov (United States)

    Benndorf, Matthias; Burnside, Elizabeth S; Herda, Christoph; Langer, Mathias; Kotter, Elmar

    2015-08-01

    Lesions detected at mammography are described with a highly standardized terminology: the breast imaging-reporting and data system (BI-RADS) lexicon. Up to now, no validated semantic computer assisted classification algorithm exists to interactively link combinations of morphological descriptors from the lexicon to a probabilistic risk estimate of malignancy. The authors therefore aim at the external validation of the mammographic mass diagnosis (MMassDx) algorithm. A classification algorithm like MMassDx must perform well in a variety of clinical circumstances and in datasets that were not used to generate the algorithm in order to ultimately become accepted in clinical routine. The MMassDx algorithm uses a naïve Bayes network and calculates post-test probabilities of malignancy based on two distinct sets of variables, (a) BI-RADS descriptors and age ("descriptor model") and (b) BI-RADS descriptors, age, and BI-RADS assessment categories ("inclusive model"). The authors evaluate both the MMassDx (descriptor) and MMassDx (inclusive) models using two large publicly available datasets of mammographic mass lesions: the digital database for screening mammography (DDSM) dataset, which contains two subsets from the same examinations-a medio-lateral oblique (MLO) view and cranio-caudal (CC) view dataset-and the mammographic mass (MM) dataset. The DDSM contains 1220 mass lesions and the MM dataset contains 961 mass lesions. The authors evaluate discriminative performance using area under the receiver-operating-characteristic curve (AUC) and compare this to the BI-RADS assessment categories alone (i.e., the clinical performance) using the DeLong method. The authors also evaluate whether assigned probabilistic risk estimates reflect the lesions' true risk of malignancy using calibration curves. The authors demonstrate that the MMassDx algorithms show good discriminatory performance. AUC for the MMassDx (descriptor) model in the DDSM data is 0.876/0.895 (MLO/CC view) and AUC

  9. Using tumor phenotype, histological tumor distribution, and mammographic appearance to explain the survival differences between screen-detected and clinically detected breast cancers.

    Science.gov (United States)

    Chuang, Shu-Lin; Chen, Sam Li-Sheng; Yu, Cheng-Ping; Chang, King-Jen; Yen, Amy Ming-Fang; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Tabár, László; Stephen, Duffy W; Smith, Robert A; Chen, Hsiu-Hsi

    2014-08-01

    In the era of mass screening for breast cancer with mammography, it has been noted that conventional tumor attributes and mammographic appearance are insufficient to account for the better prognosis of screen-detected tumors. Such prognostication may require additional updated pathological information regarding tumor phenotype (e.g., basal status) and histological tumor distribution (focality). We investigated this hypothesis using a Bayesian approach to analyze breast cancer data from Dalarna County, Sweden. We used data for tumors diagnosed in the Swedish Two-County Trial and early service screening period, 1977-1995, and from the mature service screening period, 1996-1998. In the early period of mammographic screening (1977-1995), the crude hazard ratio (HR) of breast cancer death for screen-detected cases compared with symptomatic ones was 0.22 (95% CI: 0.17-0.29) compared with 0.53 (95% CI: 0.34-0.76) when adjusted for conventional tumor attributes only. Using the data from the mature service screening period, 1996-1998, the HR was 0.23 (95% CI: 0.08-0.44) unadjusted and 0.71 (95% CI: 0.26-1.47) after adjustment for tumor phenotype, mammographic appearance, histological tumor distribution, and conventional tumor attributes. The area under the ROC curve (AUC) for the prediction of breast cancer deaths using these variables without the detection mode was 0.82, only slightly less than that observed when additionally including the detection mode (AUC=0.83). Using Freedman statistics, conventional tumor attributes and mammographic appearances explained 58% (95% CI: 57.5-58.6%) of the difference of breast cancer survival between the screen-detected and the clinically detected breast cancers, whereas the corresponding figure was increased to 77% (95% CI: 75.6-77.6%) when adding the two information on tumor phenotype and histological tumor distribution. The results indicated that conventional tumor attributes and mammographic appearance are not sufficient to be

  10. Mammographic density and ageing: A collaborative pooled analysis of cross-sectional data from 22 countries worldwide.

    Directory of Open Access Journals (Sweden)

    Anya Burton

    2017-06-01

    Full Text Available Mammographic density (MD is one of the strongest breast cancer risk factors. Its age-related characteristics have been studied in women in western countries, but whether these associations apply to women worldwide is not known.We examined cross-sectional differences in MD by age and menopausal status in over 11,000 breast-cancer-free women aged 35-85 years, from 40 ethnicity- and location-specific population groups across 22 countries in the International Consortium on Mammographic Density (ICMD. MD was read centrally using a quantitative method (Cumulus and its square-root metrics were analysed using meta-analysis of group-level estimates and linear regression models of pooled data, adjusted for body mass index, reproductive factors, mammogram view, image type, and reader. In all, 4,534 women were premenopausal, and 6,481 postmenopausal, at the time of mammography. A large age-adjusted difference in percent MD (PD between post- and premenopausal women was apparent (-0.46 cm [95% CI: -0.53, -0.39] and appeared greater in women with lower breast cancer risk profiles; variation across population groups due to heterogeneity (I2 was 16.5%. Among premenopausal women, the √PD difference per 10-year increase in age was -0.24 cm (95% CI: -0.34, -0.14; I2 = 30%, reflecting a compositional change (lower dense area and higher non-dense area, with no difference in breast area. In postmenopausal women, the corresponding difference in √PD (-0.38 cm [95% CI: -0.44, -0.33]; I2 = 30% was additionally driven by increasing breast area. The study is limited by different mammography systems and its cross-sectional rather than longitudinal nature.Declines in MD with increasing age are present premenopausally, continue postmenopausally, and are most pronounced over the menopausal transition. These effects were highly consistent across diverse groups of women worldwide, suggesting that they result from an intrinsic biological, likely hormonal, mechanism common to

  11. Should breast MRI be performed with adjustment for the phase in patients’ menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2012-01-01

    Purpose: The purpose of this study was to assess the correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle. Material and methods: The background enhancement of bilateral breast MRI and the breast density of mammography in 146 consecutive women without adjusting for the phase in patients’ menstrual cycle were reviewed. The breast density was classified into four categories according to the American College of Radiology the Breast Imaging Reporting and Data System lexicon. The background enhancement was classified into four categories: minimal, mild, moderate, and marked. The correlations of mammographic breast density as well as age with background enhancement on breast MRI were examined. Results: There was a significant correlation between mammographic breast density and background enhancement (p = 0.011). All nine cases with almost completely fat mammographic breast density showed minimal (78%) or mild (12%) background enhancement on breast MRI. There was a significant inverse correlation between age and background enhancement (p < 0.0001). Younger patients with dense breasts were more likely to demonstrate moderate/marked background enhancement. Conclusion: When no adjusting for the phase in patients’ menstrual cycle, a significant correlation was observed between background enhancement and mammographic density. A significant inverse correlation was also observed between age and background enhancement.

  12. Possible effects of insulin-like growth factor-I, IGF-binding protein-3 and IGF-1/IGFBP-3 molar ratio on mammographic density: a cross-sectional study.

    Science.gov (United States)

    Meggiorini, M L; Cipolla, V; Borgoni, G; Nofroni, I; Pala, A; de Felice, C

    2012-01-01

    The purpose of this study was to examine the possible effects of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density and assess whether this relationship was similar in subgroups of pre- and postmenopausal women. A group of 341 Italian women of childbearing age or naturally postmenopausal who had performed mammographic examination at the section of radiology of our department a maximum three months prior to recruitment were enrolled. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels and IGF-1/IGFBP-3 molar ratio was calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). To assess the association between mammographic density and IGF-1, IGFBP-3 and Molar ratio Student's t-test was employed before and after stratified by menopausal status. The analysis of the relationship between mammographic density and plasma levels of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group whereas IGFBP-3 showed similar values in both groups (DB and NDB). After stratification of the study population by menopausal status, no association was found. Our study provides strong evidence of a crude association between breast density, and plasma levels of IGF-1 and molar ratio. IGF-1 and molar ratio might increase mammographic density and thus the risk of developing breast cancer.

  13. Predicting error in detecting mammographic masses among radiology trainees using statistical models based on BI-RADS features

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Lars J., E-mail: Lars.grimm@duke.edu; Ghate, Sujata V.; Yoon, Sora C.; Kim, Connie [Department of Radiology, Duke University Medical Center, Box 3808, Durham, North Carolina 27710 (United States); Kuzmiak, Cherie M. [Department of Radiology, University of North Carolina School of Medicine, 2006 Old Clinic, CB No. 7510, Chapel Hill, North Carolina 27599 (United States); Mazurowski, Maciej A. [Duke University Medical Center, Box 2731 Medical Center, Durham, North Carolina 27710 (United States)

    2014-03-15

    Purpose: The purpose of this study is to explore Breast Imaging-Reporting and Data System (BI-RADS) features as predictors of individual errors made by trainees when detecting masses in mammograms. Methods: Ten radiology trainees and three expert breast imagers reviewed 100 mammograms comprised of bilateral medial lateral oblique and craniocaudal views on a research workstation. The cases consisted of normal and biopsy proven benign and malignant masses. For cases with actionable abnormalities, the experts recorded breast (density and axillary lymph nodes) and mass (shape, margin, and density) features according to the BI-RADS lexicon, as well as the abnormality location (depth and clock face). For each trainee, a user-specific multivariate model was constructed to predict the trainee's likelihood of error based on BI-RADS features. The performance of the models was assessed using area under the receive operating characteristic curves (AUC). Results: Despite the variability in errors between different trainees, the individual models were able to predict the likelihood of error for the trainees with a mean AUC of 0.611 (range: 0.502–0.739, 95% Confidence Interval: 0.543–0.680,p < 0.002). Conclusions: Patterns in detection errors for mammographic masses made by radiology trainees can be modeled using BI-RADS features. These findings may have potential implications for the development of future educational materials that are personalized to individual trainees.

  14. Predicting error in detecting mammographic masses among radiology trainees using statistical models based on BI-RADS features.

    Science.gov (United States)

    Grimm, Lars J; Ghate, Sujata V; Yoon, Sora C; Kuzmiak, Cherie M; Kim, Connie; Mazurowski, Maciej A

    2014-03-01

    The purpose of this study is to explore Breast Imaging-Reporting and Data System (BI-RADS) features as predictors of individual errors made by trainees when detecting masses in mammograms. Ten radiology trainees and three expert breast imagers reviewed 100 mammograms comprised of bilateral medial lateral oblique and craniocaudal views on a research workstation. The cases consisted of normal and biopsy proven benign and malignant masses. For cases with actionable abnormalities, the experts recorded breast (density and axillary lymph nodes) and mass (shape, margin, and density) features according to the BI-RADS lexicon, as well as the abnormality location (depth and clock face). For each trainee, a user-specific multivariate model was constructed to predict the trainee's likelihood of error based on BI-RADS features. The performance of the models was assessed using area under the receive operating characteristic curves (AUC). Despite the variability in errors between different trainees, the individual models were able to predict the likelihood of error for the trainees with a mean AUC of 0.611 (range: 0.502-0.739, 95% Confidence Interval: 0.543-0.680,p errors for mammographic masses made by radiology trainees can be modeled using BI-RADS features. These findings may have potential implications for the development of future educational materials that are personalized to individual trainees.

  15. Predicting error in detecting mammographic masses among radiology trainees using statistical models based on BI-RADS features

    International Nuclear Information System (INIS)

    Grimm, Lars J.; Ghate, Sujata V.; Yoon, Sora C.; Kim, Connie; Kuzmiak, Cherie M.; Mazurowski, Maciej A.

    2014-01-01

    Purpose: The purpose of this study is to explore Breast Imaging-Reporting and Data System (BI-RADS) features as predictors of individual errors made by trainees when detecting masses in mammograms. Methods: Ten radiology trainees and three expert breast imagers reviewed 100 mammograms comprised of bilateral medial lateral oblique and craniocaudal views on a research workstation. The cases consisted of normal and biopsy proven benign and malignant masses. For cases with actionable abnormalities, the experts recorded breast (density and axillary lymph nodes) and mass (shape, margin, and density) features according to the BI-RADS lexicon, as well as the abnormality location (depth and clock face). For each trainee, a user-specific multivariate model was constructed to predict the trainee's likelihood of error based on BI-RADS features. The performance of the models was assessed using area under the receive operating characteristic curves (AUC). Results: Despite the variability in errors between different trainees, the individual models were able to predict the likelihood of error for the trainees with a mean AUC of 0.611 (range: 0.502–0.739, 95% Confidence Interval: 0.543–0.680,p < 0.002). Conclusions: Patterns in detection errors for mammographic masses made by radiology trainees can be modeled using BI-RADS features. These findings may have potential implications for the development of future educational materials that are personalized to individual trainees

  16. Long-term exposure to air pollution and mammographic density in the Danish Diet, Cancer and Health cohort

    DEFF Research Database (Denmark)

    Huynh, Stephanie; von Euler-Chelpin, My; Raaschou-Nielsen, Ole

    2015-01-01

    investigated the association between long-term exposure to traffic-related air pollution and MD in a prospective cohort of women 50 years and older. METHODS: For the 4,769 women (3,930 postmenopausal) participants in the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening...... 1971 until cohort baseline (1993-97) and MD was analyzed using logistic regression, adjusting for confounders, and separately by menopause, smoking status, and obesity. RESULTS: We found inverse, statistically borderline significant associations between long-term exposure to air pollution and having...... mixed/dense MD in our fully adjusted model (OR; 95% CI: 0.96; 0.93-1.01 per 20 μg/m(3) of NOx and 0.89; 0.80- 0.98 per 10 μg/m(3) of NO2). There was no interaction with menopause, smoking, or obesity. CONCLUSION: Traffic-related air pollution exposure does not increase MD, indicating that if air...

  17. Heterogeneity of triple-negative breast cancer: mammographic, US, and MR imaging features according to androgen receptor expression

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Min Sun; Song, Sung Eun; Kim, Won Hwa; Lee, Su Hyun; Moon, Woo Kyung [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, So Yeon; Park, In-Ae [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Han, Wonshik; Noh, Dong-Young [Seoul National University College of Medicine, Department of Surgery, Seoul (Korea, Republic of)

    2014-09-16

    Our aim was to determine whether triple-negative breast cancers (TNBCs) with and without androgen receptor (AR) expression have distinguishing imaging features on mammography, breast ultrasound (US), and magnetic resonance (MR) imaging. AR expression was assessed immunohistochemically in 125 patients with TNBC from a consecutive series of 1,086 operable invasive breast cancers. Two experienced radiologists blinded to clinicopathological findings reviewed all imaging studies in consensus using the BI-RADS lexicon. The imaging and pathological features of 33 AR-positive TNBCs were compared with those of 92 AR-negative TNBCs. The presence of mammographic calcifications with or without a mass (p < 0.001), non-mass enhancement on MR imaging (p < 0.001), and masses with irregular shape or spiculated margins on US (p < 0.001 and p = 0.002) and MR imaging (p = 0.001 and p < 0.001) were significantly associated with AR-positive TNBC. Compared with AR-negative TNBC, AR-positive TNBC was more likely to have a ductal carcinoma in situ component (59.8 % vs. 90.9 %, p = 0.001) and low Ki-67 expression (30.4 % vs. 51.5 %, p = 0.030). AR-positive and AR-negative TNBCs have different imaging features, and certain imaging findings can be useful to predict AR status in TNBC. (orig.)

  18. Early mammographic and sonographic findings after intraoperative radiotherapy (IORT) as a boost in patients with breast cancer

    International Nuclear Information System (INIS)

    Wasser, K.; Schoeber, C.; Neff, W.; Kraus-Tiefenbacher, U.; Wenz, F.; Bauer, L.; Brade, J.; Teubner, J.

    2007-01-01

    The aim of this study was to evaluate mammographic and sonographic changes at the surgical site within the first 2 years after IORT as a boost followed by whole-breast radiotherapy (WBRT), compared with a control group treated with WBRT alone. All patients had breast-conserving surgery for early-stage breast cancer. Group A: n = 27, IORT (20 Gy) followed by WBRT (46 Gy). Group B (control group): n = 27, WBRT alone (56-66 Gy). Mammography: fat necrosis in 14 group A versus four group B patients (P < 0.001); parenchymal scarring classified as unorganized at the last follow-up in 16 vs seven cases, respectively (P = 0.03). Ultrasound: overall number of patients with circumscribed findings 27 vs 18 (P < 0.001); particular hematomas/seromas in 26 vs 13 patients (P < 0.001). Synopsis of mammography and ultrasound: overall postoperative changes were significantly higher classified in group A (P = 0.01), but not judged to have a significantly higher impact on interpretation. Additional diagnostic procedures, due to unclear findings at the surgical site, were performed on four patients of both groups. Within the first 2 years after IORT as a boost, therapy-induced changes at the original tumor site are significantly more pronounced compared with a control group. There is no evidence that the interpretation of findings is complicated after IORT. (orig.)

  19. Detecting mammographically occult cancer in women with dense breasts using Radon Cumulative Distribution Transform: a preliminary analysis

    Science.gov (United States)

    Lee, Juhun; Nishikawa, Robert M.; Rohde, Gustavo K.

    2018-02-01

    We propose using novel imaging biomarkers for detecting mammographically-occult (MO) cancer in women with dense breast tissue. MO cancer indicates visually occluded, or very subtle, cancer that radiologists fail to recognize as a sign of cancer. We used the Radon Cumulative Distribution Transform (RCDT) as a novel image transformation to project the difference between left and right mammograms into a space, increasing the detectability of occult cancer. We used a dataset of 617 screening full-field digital mammograms (FFDMs) of 238 women with dense breast tissue. Among 238 women, 173 were normal with 2 - 4 consecutive screening mammograms, 552 normal mammograms in total, and the remaining 65 women had an MO cancer with a negative screening mammogram. We used Principal Component Analysis (PCA) to find representative patterns in normal mammograms in the RCDT space. We projected all mammograms to the space constructed by the first 30 eigenvectors of the RCDT of normal cases. Under 10-fold crossvalidation, we conducted quantitative feature analysis to classify normal mammograms and mammograms with MO cancer. We used receiver operating characteristic (ROC) analysis to evaluate the classifier's output using the area under the ROC curve (AUC) as the figure of merit. Four eigenvectors were selected via a feature selection method. The mean and standard deviation of the AUC of the trained classifier on the test set were 0.74 and 0.08, respectively. In conclusion, we utilized imaging biomarkers to highlight differences between left and right mammograms to detect MO cancer using novel imaging transformation.

  20. Accuracy and reading time for six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts.

    Science.gov (United States)

    Tagliafico, Alberto Stefano; Calabrese, Massimo; Bignotti, Bianca; Signori, Alessio; Fisci, Erica; Rossi, Federica; Valdora, Francesca; Houssami, Nehmat

    2017-12-01

    To compare six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts. This is a substudy of the 'ASTOUND' trial. 163 women who underwent tomosynthesis with synthetically reconstructed projection images (S-2D) inclusive of 13 (7.9%) cases diagnosed with breast cancer at histopathology after surgery were evaluated. Accuracy measures and screen-reading time of six reading strategies were assessed: (A) Single reading of S-2D alone, (B) single reading of tomosynthesis alone, (C) single reading of joint interpretation of tomosynthesis + S-2D, (D) double-reading of S-2D alone, (E) double reading of tomosynthesis alone, (F) double reading of joint interpretation of tomosynthesis + S-2D. The median age of the patients was 53 years (range, 36-88 years). The highest global accuracy was obtained with double reading of tomosynthesis + S2D (F) with an AUC of 0.979 (ptomosynthesis+ S2D had the best accuracy of six screen-reading strategies although it had the longest reading time. • Tomosynthesis acquisitions are progressively implemented with reconstructed synthesized 2D images • Double reading using S-2D plus tomosynthesis had the highest global accuracy (ptomosynthesis increased reading time.

  1. Is the presence of mammographic comedo calcification really a prognostic factor for small screen-detected invasive breast cancers?

    International Nuclear Information System (INIS)

    James, J.J.; Evans, A.J.; Pinder, S.E.; Macmillan, R.D.; Wilson, A.R.M.; Ellis, I.O.

    2003-01-01

    AIM: It has been suggested that the use of traditional prognostic factors such as histological grade and lymph node stage are not reliable predictors of outcome for small ( 2 = 9.68,P = 0.008). No significant association was demonstrated between the presence of comedo calcification and survival. Multivariate analysis confirmed lymph node stage as the only independent prognostic factor for these small screen-detected breast cancers (χ 2 = 7.18,P = 0.007). There were significant associations between the presence of comedo calcification on the screening mammogram and high histological grade and small tumour size. CONCLUSION: Although the overall outcome for small screen-detected breast cancers (<15 mm diameter) is excellent, the presence of lymph node metastases is associated with a significant reduction in long-term survival. The presence of mammographic comedo calcification is not an independent prognostic factor, but is closely related to histological grade. James, J. J. et al. (2003). Clinical Radiology, 58, 54-62

  2. How good is better? A comparison between the Medipix1 and the Medipix2 chip using mammographic phantoms

    International Nuclear Information System (INIS)

    Pfeiffer, K.F.G.

    2003-01-01

    Full text: The Mixed-up chip is the successor to the Medipix 1 chip and was also developed within the framework of the Medipix Colaboration. Both chips are pixel detector readout chips working in single photon counting mode and are designed for direct conversion X-ray imaging, for which they are bump-bonded to a pixelated semiconductor sensor layer. Both assemblies used in this comparison have a 300 μm thick sensor layer made of silicon. The main changes realized in the second chip generation are the smaller pixel size of 55 μm x 55 μm, the larger number of pixels (256 x 256) and a second adjustable energy threshold which facilitates energy windowing. For comparing the two detector generations, mammographic phantoms and a suitable X-ray tube have been used. By imaging selected parts of the phantoms with both detectors under the same conditions it is possible to make a direct comparison between the imaging properties of both chips. Main aspects of the experiments were the resolution of high-contrast details and low-contrast imaging. To provide a reference point for image quality the phantoms were also imaged using standard clinical equipment. Since these measurements have been made without an anti-scatter grid, additional simulations have been performed to estimate the influence of scattered photons on the image quality

  3. Red mercuric iodide crystals obtained by isothermal solution evaporation: Characterization for mammographic X-ray imaging detectors

    Energy Technology Data Exchange (ETDEWEB)

    Caldeira, A.M.F.; Ugucioni, J.C.; Mulato, M.

    2014-02-11

    Millimeter-sized mercury iodide crystals were obtained by the isothermal evaporation technique using dimethylformamide (DMF), diethyl-ether/DMF mixture and THF. Different concentrations (18 mM and 400 mM) and solution temperature (25–80 °C) were used to obtain varied evaporation rates (0.1×10{sup −4}–5000×10{sup −4} ml/h). Different crystal sizes and shapes were obtained by changing solvents, mixture and initial solution volume. According to X-ray diffraction the samples are monocrystalline. The top surface was investigated by SEM. Optical band-gaps above 2 eV were obtained from photoacoustic spectroscopy. Photoluminescence spectra indicated band-to-band electronic transitions, and the presence of sub-band gap states. Excitons, structural defects and the presence of impurities are discussed and correlated to the electrical measurements. Crystals obtained using pure DMF as solvent showed better general properties, including under the exposure to mammographic X-ray energy range that led to sensibility of about 25 μC/Rcm{sup 2}.