WorldWideScience

Sample records for cutoff walls

  1. Development of a high-quality cut-off wall using electrophoresis

    International Nuclear Information System (INIS)

    Kawachi, T.; Murahashi, H.

    1991-01-01

    Techniques to build a high-quality cut-off wall have been developed for storage facilities of low-level radioactive waste (LLW) as an emergency measures to prevent leakages. The cut-off wall is highly impermeable, nucleid-adsorptive and have long-term durability. Electrophoresis is used to form impermeable membrane of bentonite as main features of the cut-off wall. First of all, laboratory tests have been conducted to study ways of building barriers on site and to collect data on the barriers properties. Afterwards, on-site construction tests of a high-quality cut-off wall have been carried out. In this paper, we describe the process and results on the studies of the high-quality cut-off wall using electrophoresis

  2. Vertical cut-off walls for the containment of contaminated ground

    International Nuclear Information System (INIS)

    Jessberger, H.L.; Krubasik, K.; Beine, R.A.

    1997-01-01

    Vertical cut-off walls are widely used for the containment of contaminated sites, where a capping system is not sufficient for the protection of groundwater. Various types of cut-off walls are introduced and new developments are prescribed. Design and testing principles are outlined. Containment techniques are the appropriate measure for old landfills and abandoned industrial sites with contaminated ground and groundwater, too, since the shortage of financial resources in many countries classifies clean-up techniques as too cost intensive in most cases

  3. Flow rates through earthen, geomembrane ampersand composite cut-off walls

    International Nuclear Information System (INIS)

    Tachavises, C.; Benson, C.H.

    1997-01-01

    Flow rates through soil-bentonite (SIB), geomembrane (GM), and composite geomembrane-soil (CGS) cut-off walls were determined using a numerical model of ground water flow. Various geological and wall conditions were simulated. Results of the simulations show that flow rates past all wall types are affected by hydraulic conductivities of the aquifer and underlying confining layer. Flow rates past GM walls with perfect joints are very low, provided the confining layer has low hydraulic conductivity. However, if a small fraction of the joints are defective, GM walls can be ineffective in blocking flow. CGS walls with a low hydraulic conductivity shell are less sensitive to joint defects. CGS walls with good shells typically have lower flow rates than SB and GM walls, even if the CGS wall contains defective joints

  4. Flow simulation and investigating the effects of cutoff wall on the ...

    African Journals Online (AJOL)

    Since the construction of dam is significantly important both according to economic and safety aspects, it should be carefully assessed before construction. The use of available software is one of the evaluation and behavioral investigation methods. On this basis, we have investigated the effect of cutoff wall on the seepage ...

  5. The first cut-off wall in the Indian Himalayas for the dam of the Dhauliganga hydroelectric project

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, W.G. [Bauer Maschinen GmbH, Berlin (Germany)

    2006-07-01

    This paper provided details a Bauer cutter used to build a cut-off wall for the Dhaulinganga power plant project in the Himalayan mountains. The dam for the project was built as a 56 m high concrete-faced rockfill dam with a length of 270 m at the crown. A cut-off wall was constructed on the upstream side of the dam extending down from the dam's plinth to the bedrock level. A Bauer cutter was used to key the cut-off wall straight into the bedrock, which omitted the need for a grout curtain. The cut-off wall is 1 m thick and 70 m deep, with a total area of 8000 m{sup 2}. The wall was constructed as a series of primary and secondary panels. Excavation of the panels was carried out in single bites by the Bauer DHG hydraulic diaphragm wall grabs, supported a box chisel, cross chisel and a Bauer BC 40 rock cutter. Trench stability was provided by bentonite slurry. The closing forces were activated by a cylinder which was installed vertically inside the base body. The Bauer cutter continuously removed soil and rock from the bottom of the trench for mixing with the bentonite slurry. The slurry was then pumped through a ring main of hose pipes to a desanding plant where it was cleaned and returned to the trench. Advantages offered by using the cutter included a consistently high output, an extremely high degree of verticality, watertight joints, and the ability to cut through hard boulders. Use of the cutter at the Dhaulinganga site showed that the project could not be carried out successfully without the use of the cutter, which was used whenever grab and chisel methods were unable to achieve satisfactory rates of penetration. Deployment of the cutter was essential to key the cut-off wall into the underlying bedrock. It was concluded that the Dhualinganga project will provide a model for future power generation projects in the Indian Himalayas. 11 figs.

  6. Soil-bentonite design mix for slurry cutoff walls used as containment barriers

    International Nuclear Information System (INIS)

    Rad, N.S.; Bachus, R.C.; Jacobson, B.D.

    1995-01-01

    In recent years, soil-bentonite slurry cutoff walls have been increasingly used as containment barriers around contaminated soils to impede or, in some cases, nearly eliminate the off-site migration of contaminated ground water or other potentially hazardous liquids. The paper presents the procedures used and the results obtained during an extensive laboratory testing program performed to select varying soil-bentonite slurry mix components for a soil-bentonite slurry cutoff wall constructed around an old landfill at a former oil refinery. The landfill is underlain to varying depths by a coarse granular soils that has been exposed to oil-products. Compatibility of three commercially available bentonite products with the free oil-products and the oil-contaminated ground water found at some locations in the landfill was initially investigated. Based on the test results, one of the bentonite products was selected for use in the soil-bentonite slurry testing program. A clayey soil from a borrow source, potable water from the site, and subsurface soils from the proposed soil-bentonite slurry wall alignment were used to form different soil-bentonite slurry mixes. Slump tests were performed to evaluate the workability of the mixes. Based on the test results, a single mix was selected for further study, including permeability/compatibility testing. The results of the compatibility testing program are presented and discussed in the paper. A specific design mix methodology for evaluating the chemical compatibility of soil-bentonite slurry mixes with permeants is proposed

  7. Jet grouting for a groundwater cutoff wall in difficult glacial soil deposits

    International Nuclear Information System (INIS)

    Flanagan, R.F.; Pepe, F. Jr.

    1997-01-01

    Jet grouting is being used as part of a groundwater cutoff wall system in a major New York City subway construction project to limit drawdowns in an adjacent PCB contamination plume. A circular test shaft of jet grout columns was conducted during the design phase to obtain wall installation parameters. The test program also included shaft wall mapping, and measurements of; inflows, piezometric levels, ground heave and temperature, and jet grout hydraulic conductivity. An axisymmetric finite element method groundwater model was established to back calculate the in-situ hydraulic conductivities of both the surrounding glacial soils and the jet grout walls by matching observed inflows and piezometric levels. The model also verified the use of packer permeability test as a tool in the field to evaluate the hydraulic conductivities of jet grout columns. Both the test program and analytic studies indicated that adjustments to the construction procedures would be required to obtain lower hydraulic conductivities of the jet grout walls for construction. A comparison is made with the conductivities estimated from the test program/analytic studies with those from the present construction

  8. European quality assurance and quality control for cut-off walls and caps

    International Nuclear Information System (INIS)

    Jefferis, S.A.

    1997-01-01

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  9. Investigation of the performance of cement-bentonite cut-off walls in aggressive ground at a disused gasworks site

    International Nuclear Information System (INIS)

    Tedd, P.; Holton, I.R.; Butcher, A.P.; Wallace, S.

    1997-01-01

    There has been an increased use of cement-bentonite slurry trench cut-off walls to control the lateral migration of pollution in the UK. Concerns inevitably exist about their performance in chemically aggressive ground particularly in the long term. To address some of the uncertainties a programme of field and laboratory research is being undertaken at a disused gasworks in the UK. Elevated levels of sulphate and other contaminants are present on the site and could potentially change the properties of the cement-bentonite. Two boxes, 10m square in plan, by 5m deep have been constructed, one with and one without an HDPE membrane, to isolate parts of the site. Local hydraulic gradients across the walls have been created by pumping from within the boxes. Isolated lengths of wall have been constructed which are being used to assess and develop in-situ testing techniques such as the piezocone for measuring permeability, strength and overall integrity of the wall

  10. On Computations of Duct Acoustics with Near Cut-Off Frequency

    Science.gov (United States)

    Dong, Thomas Z.; Povinelli, Louis A.

    1997-01-01

    The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.

  11. Techniques for beam impedance measurements above cutoff

    International Nuclear Information System (INIS)

    Lambertson, G.R.; Jacob, A.F.; Rimmer, R.A.; Voelker, F.

    1990-08-01

    Methods for measuring beam impedance above cutoff have been very limited. For design work on the ALS we have developed two techniques that yield data in the frequency domain with high sensitivity. The first is an extension of the wire method; the second utilizes traveling TM waves to simulate the beam's fields at the wall, and thus avoids the mechanical difficulties of mounting the wire. It is also more sensitive than the other method but the interpretation is complicated by the presence of higher order modes. With either method we were able to detect resonant peaks smaller than 1 Ohm at 10 GHz

  12. The origins of the slurry trench cut-off and a review of cement-bentonite cut-off walls in the UK

    International Nuclear Information System (INIS)

    Jefferis, S.A.

    1997-01-01

    On the occasion of the first International Containment Technology Conference it is appropriate to look back to the origins of containment walls as well as forward to the new technologies that we may need for the complex chemical and physical environments in which containment may be employed in the future. This paper looks at the development of slurry trench technology from the first concepts in 1938, the first field trials in 1945 and on to the cement-bentonite walls used in the UK today and the issues associated with defining appropriate materials performance

  13. Dressed Domain Walls and holography

    International Nuclear Information System (INIS)

    Grisa, Luca; Pujolas, Oriol

    2008-01-01

    The cutoff version of the AdS/CFT correspondence states that the Randall Sundrum scenario is dual to a Conformal Field Theory (CFT) coupled to gravity in four dimensions. The gravitational field produced by relativistic Domain Walls can be exactly solved in both sides of the correspondence, and thus provides one further check of it. We show in the two sides that for the most symmetric case, the wall motion does not lead to particle production of the CFT fields. Still, there are nontrivial effects. Due to the trace anomaly, the CFT effectively renormalizes the Domain Wall tension. On the five dimensional side, the wall is a codimension 2 brane localized on the Randall-Sundrum brane, which pulls the wall in a uniform acceleration. This is perceived from the brane as a Domain Wall with a tension slightly larger than its bare value. In both cases, the deviation from General Relativity appears at nonlinear level in the source, and the leading corrections match to the numerical factors.

  14. Fatigue life analysis of cracked gas receiver of emergency cut-off system in gas gathering station

    Science.gov (United States)

    Hu, Junzhi; Zhou, Jiyong; Li, Siyuan

    2017-06-01

    Small-scale air compressor and gas receiver are used as the driving gas of the emergency cut-off system in gas gathering station. Operation of block valve is ensured by starting and stopping compressor automatically. The frequent start-stop of compressor and the pressure fluctuation pose a threat to the service life of gas receiver, and then affect normal operation of the emergency cut-off system and security of gas gathering station. In this paper, the fatigue life of a pressure vessel with axial semi-elliptical surface crack in the inner wall is analyzed under the varying pressure by means of the theory of fracture mechanics. The influences of the amplitude of pressure fluctuation and the initial crack size on the residual life of gas receiver are discussed. It provides a basis for setting the working parameters of gas receiver of emergency cut-off system and determining the maintenance cycle.

  15. Attenuation in Rectangular Waveguides with Finite Conductivity Walls

    Directory of Open Access Journals (Sweden)

    K. C. Yeong

    2011-06-01

    Full Text Available We present a fundamental and accurate approach to compute the attenuation of electromagnetic waves propagating in rectangular waveguides with finite conductivity walls. The wavenumbers kx and ky in the x and y directions respectively, are obtained as roots of a set of transcendental equations derived by matching the tangential component of the electric field (E and the magnetic field (H at the surface of the waveguide walls. The electrical properties of the wall material are determined by the complex permittivity ε, permeability μ, and conductivity σ. We have examined the validity of our model by carrying out measurements on the loss arising from the fundamental TE10 mode near the cutoff frequency. We also found good agreement between our results and those obtained by others including Papadopoulos’ perturbation method across a wide range of frequencies, in particular in the vicinity of cutoff. In the presence of degenerate modes however, our method gives higher losses, which we attribute to the coupling between modes as a result of dispersion.

  16. Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography

    International Nuclear Information System (INIS)

    Luboldt, W.; Kroll, M.; Wetter, A.; Vogl, T.J.; Toussaint, T.L.; Hoepffner, N.; Holzer, K.; Kluge, A.

    2004-01-01

    A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps 0 . The slope m was determined by linear regression in the correlation (lesion ∝[xA + (1 - x)V]//H) and the Y-intercept y 0 by the minimal shift of the line needed to maximize the accuracy of separating the colonic wall from the lesions. The CT value of the lesions correlated best with the intermediate phase: 0.4A+ 0.6V(r=0.8 for polyps ≥10 mm, r=0.6 for carcinomas, r=0.4 for polyps <10 mm). The accuracy in the differentiation between lesions and normal colonic wall increased with the height implemented as divisor, reached 91% and was obtained by the dynamic cut-off described by the formula: cut-off(A,V,H) = 1.1[0.4A + 0.6V]/H + 69.8. The CT value of colonic polyps or carcinomas can be increased extrinsically by scanning in the phase in which 0.4A + 0.6V reaches its maximum. Differentiating lesions from normal colon based on CT values is possible in contrast-enhanced CTC and improves when the cut-off is adjusted (normalized) to the contrast phase and lesion size. (orig.)

  17. Reissner-Nordstrom Black Hole Entropy Inside and Outside the Brick Wall

    Institute of Scientific and Technical Information of China (English)

    刘文彪

    2003-01-01

    Applying the generalized uncertainty relation to the calculation of the free energy and entropy of a Reissner Nordstrom black hole inside the brick wall, the entropy proportional to the horizon area is derived from the contribution of the vicinity of the horizon. This is compared with the entropy calculated via the original brick wall model. The entropy given by the original brick wall model comes from the outside of the brick wall seemingly.The inside result using generalized uncertainty relation is similar to the outside result using original uncertainty relation, and the divergence inside the brick wall disappears. It is apparent that the cutoff is something related to the quantum theory of gravity.

  18. Plasma density measurement with ring-type cutoff probe

    International Nuclear Information System (INIS)

    Kim, D.W.; You, S.J.; Na, B.K.; Kim, J.H.; Shin, Y.H.; Chang, H.Y.; Oh, W.Y.

    2013-01-01

    We proposed a cutoff probe with a ring-type detection tip enclosing a bar-type radiation tip. A comparative study between a proposed ring-type cutoff (RTC) probe and a conventional bar-type cutoff (BTC) probe showed that the RTC probe solved the problem of the BTC probe, the large measurement uncertainty of the electron density in a capacitively coupled plasma source. This improved characteristics of the RTC probe might have originated from the geometrical structure of the RTC probe concerning the monopole antennae radiation. This proposed cutoff probe can be expected to expand the applicable diagnostic range and to enhance the sensitivity of the cutoff probe. - Highlights: ► A cutoff probe with a ring type detection tip is proposed. ► Comparative experiment and simulation were conducted. ► The proposed probe showed a small uncertainty of measured plasma density. ► Improved characteristics might be originated from the geometrical structure

  19. Gauge invariance in the presence of a cutoff

    International Nuclear Information System (INIS)

    Kvinikhidze, A. N.; Blankleider, B.; Epelbaum, E.; Hanhart, C.; Valderrama, M. Pavon

    2009-01-01

    We use the method of gauging equations to construct the electromagnetic current operator for the two-nucleon system in a theory with a finite cutoff. The employed formulation ensures that the two-nucleon T-matrix and corresponding five-point function, in the cutoff theory, are identical to the ones formally defined by a reference theory without a cutoff. A feature of our approach is that it effectively introduces a cutoff into the reference theory in a way that maintains the long-range part of the exchange current operator; for applications to effective field theory (EFT), this property is usually sufficient to guarantee the predictive power of the resulting cutoff theory. In addition, our approach leads to Ward-Takahashi (WT) identities that are linear in the interactions. From the point of view of EFT's where such a WT identity is satisfied in the reference theory, this ensures that gauge invariance in the cutoff theory is maintained order by order in the expansion.

  20. Further analysis of the BFKL equation with momentum cutoffs

    International Nuclear Information System (INIS)

    McDermott, M.F.; Forshaw, J.R.

    1996-06-01

    In this paper we investigate the effect of introducing transverse momentum cutoffs on the BFKL equation. We present solutions in moment space for various models of the BFKL kernel for different combinations of these cutoffs. We improve on previous calculations by using the full BFKL kernel (rather than simplified analytic approximations). The significance of the next-to-leading or higher twist terms in the kernel are assessed. We find that, while these terms are negligible in the absence of cutoffs, introducing an infra-red cutoff markedly enhances their significance. (orig.)

  1. Chronic abdominal wall pain misdiagnosed as functional abdominal pain.

    Science.gov (United States)

    van Assen, Tijmen; de Jager-Kievit, Jenneke W A J; Scheltinga, Marc R; Roumen, Rudi M H

    2013-01-01

    The abdominal wall is often neglected as a cause of chronic abdominal pain. The aim of this study was to identify chronic abdominal wall pain syndromes, such as anterior cutaneous nerve entrapment syndrome (ACNES), in a patient population diagnosed with functional abdominal pain, including irritable bowel syndrome, using a validated 18-item questionnaire as an identification tool. In this cross-sectional analysis, 4 Dutch primary care practices employing physicians who were unaware of the existence of ACNES were selected. A total of 535 patients ≥18 years old who were registered with a functional abdominal pain diagnosis were approached when they were symptomatic to complete the questionnaire (maximum 18 points). Responders who scored at least the 10-point cutoff value (sensitivity, 0.94; specificity, 0.92) underwent a diagnostic evaluation to establish their final diagnosis. The main outcome was the presence and prevalence of ACNES in a group of symptomatic patients diagnosed with functional abdominal pain. Of 535 patients, 304 (57%) responded; 167 subjects (31%) recently reporting symptoms completed the questionnaire. Of 23 patients who scored above the 10-point cutoff value, 18 were available for a diagnostic evaluation. In half of these subjects (n = 9) functional abdominal pain (including IBS) was confirmed. However, the other 9 patients were suffering from abdominal wall pain syndrome, 6 of whom were diagnosed with ACNES (3.6% prevalence rate of symptomatic subjects; 95% confidence interval, 1.7-7.6), whereas the remaining 3 harbored a painful lipoma, an abdominal herniation, and a painful scar. A clinically relevant portion of patients previously diagnosed with functional abdominal pain syndrome in a primary care environment suffers from an abdominal wall pain syndrome such as ACNES.

  2. Reproducibility of the cutoff probe for the measurement of electron density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. W.; Oh, W. Y. [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); You, S. J., E-mail: sjyou@cnu.ac.kr [Department of Physics, Chungnam National University, Daejeon 305-701 (Korea, Republic of); Kwon, J. H.; You, K. H.; Seo, B. H.; Kim, J. H., E-mail: jhkim86@kriss.re.kr [Center for Vacuum Technology, Korea Research Institute of Standards and Science, Daejeon 305-306 (Korea, Republic of); Yoon, J.-S. [Plasma Technology Research Center, National Fusion Research Institute, Gunsan 573-540 (Korea, Republic of)

    2016-06-15

    Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

  3. Reproducibility of the cutoff probe for the measurement of electron density

    International Nuclear Information System (INIS)

    Kim, D. W.; Oh, W. Y.; You, S. J.; Kwon, J. H.; You, K. H.; Seo, B. H.; Kim, J. H.; Yoon, J.-S.

    2016-01-01

    Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

  4. Analysis of prestressed concrete wall segments

    International Nuclear Information System (INIS)

    Koziak, B.D.P.; Murray, D.W.

    1979-06-01

    An iterative numerical technique for analysing the biaxial response of reinforced and prestressed concrete wall segments subject to combinations of prestressing, creep, temperature and live loads is presented. Two concrete constitutive relations are available for this analysis. The first is a uniaxially bilinear model with a tension cut-off. The second is a nonlinear biaxial relation incorporating equivalent uniaxial strains to remove the Poissons's ratio effect under biaxial loading. Predictions from both the bilinear and nonlinear model are compared with observations from experimental wall segments tested in tension. The nonlinear model results are shown to be close to those of the test segments, while the bilinear results are good up to cracking. Further comparisons are made between the nonlinear analysis using constant membrane force-moment ratios, constant membrane force-curvature ratios, and a nonlinear finite difference analysis of a test containment structure. Neither nonlinear analysis could predict the reponse of every wall segment within the structure, but the constant membrane force-moment analysis provided lower bound results. (author)

  5. Cutoff effects in O(N) nonlinear sigma models

    International Nuclear Information System (INIS)

    Knechtli, Francesco; Leder, Bjoern; Wolff, Ulli

    2005-01-01

    In the nonlinear O(N) sigma model at N=3 unexpected cutoff effects have been found before with standard discretizations and lattice spacings. Here the situation is analyzed further employing additional data for the step scaling function of the finite volume mass gap at N=3,4,8 and a large N-study of the leading as well as next-to-leading terms in 1/N. The latter exact results are demonstrated to follow Symanzik's form of the asymptotic cutoff dependence. At the same time, when fuzzed with artificial statistical errors and then fitted like the Monte Carlo results, a picture similar to N=3 emerges. We hence cannot conclude a truly anomalous cutoff dependence but only relatively large cutoff effects, where the logarithmic component is important. Their size shrinks at larger N, but the structure remains similar. The large N results are particularly interesting as we here have exact nonperturbative control over an asymptotically free model both in the continuum limit and on the lattice

  6. Cutoff effects in O(N) nonlinear sigma models

    International Nuclear Information System (INIS)

    Knechtli, F.; Wolff, U.; Leder, B.

    2005-06-01

    In the nonlinear O(N) sigma model at N=3 unexpected cutoff effects have been found before with standard discretizations and lattice spacings. Here the situation is analyzed further employing additional data for the step scaling function of the finite volume mass gap at N=3,4,8 and a large N-study of the leading as well as next-to-leading terms in 1/N. The latter exact results are demonstrated to follow Symanzik's form of the asymptotic cutoff dependence. At the same time, when fuzzed with artificial statistical errors and then fitted like the Monte Carlo results, a picture similar to N=3 emerges. We hence cannot conclude a truly anomalous cutoff dependence but only relatively large cutoff effects, where the logarithmic component is important. Their size shrinks at larger N, but the structure remains similar. The large N results are particularly interesting as we here have exact nonperturbative control over an asymptotically free model both in the continuum limit and on the lattice. (orig.)

  7. Cut-off frequency of magnetostrictive materials based on permeability spectra

    International Nuclear Information System (INIS)

    Meng Hao; Zhang Tianli; Jiang Chengbao

    2012-01-01

    The loss behavior and cut-off frequency of TbDyFe alloy and TbDyFe/epoxy composite have been investigated by measuring their permeability spectra. The loss factor of TbDyFe alloy increases exponentially as the frequency goes up, while it is almost unchanged for the TbDyFe/epoxy composite. The loss factor value for the TbDyFe composite is only 4.3% of that for the monolithic TbDyFe alloy at high frequency of 10 kHz under the peak magnetic induction of 10 mT. The cut-off frequency of TbDyFe/epoxy composite is 6800 kHz, 3 orders of magnitude larger than that of TbDyFe alloy. The cut-off frequency is found to be the ferromagnetic resonance frequency and can be calculated from Snoek's law. - Highlights: ► The cut-off frequency of TbDyFe alloy and TbDyFe/epoxy composite has been investigated. ► Permeability spectra are used to study loss behavior and cut-off frequency. ► A mathematic formula is deduced to predict the cut-off frequency. ► TbDyFe/epoxy composite presents high cut-off frequency of 6800 kHz.

  8. Cut-off Grade Optimization for Maximizing the Output Rate

    Directory of Open Access Journals (Sweden)

    A. Khodayari

    2012-12-01

    Full Text Available In the open-pit mining, one of the first decisions that must be made in production planning stage, after completing the design of final pit limits, is determining of the processing plant cut-off grade. Since this grade has an essential effect on operations, choosing the optimum cut-off grade is of considerable importance. Different goals may be used for determining optimum cut-off grade. One of these goals may be maximizing the output rate (amount of product per year, which is very important, especially from marketing and market share points of view. Objective of this research is determining the optimum cut-off grade of processing plant in order to maximize output rate. For performing this optimization, an Operations Research (OR model has been developed. The object function of this model is output rate that must be maximized. This model has two operational constraints namely mining and processing restrictions. For solving the model a heuristic method has been developed. Results of research show that the optimum cut-off grade for satisfying pre-stated goal is the balancing grade of mining and processing operations, and maximum production rate is a function of the maximum capacity of processing plant and average grade of ore that according to the above optimum cut-off grade must be sent to the plant.

  9. Cut-off of electric consumption in France. Assessment of the cut-off potential by process modulation in industrial and tertiary sectors in metropolitan France. Final report + Synthesis

    International Nuclear Information System (INIS)

    Bertholon, Marion; Streiff, Frederic; Marchal, David; Bouchet, Alexandre; Foucher, Julie-Anne; Hoffer, Alexandre; Millet, Bruno; Sorlier, Pierre; Peron, Nicolas; Creon, Nicolas; Lenet, Sylvain; Guillet, Frederic; Mounier, Cyril; Charton, Franck; Duclos, Herve; Lenain, Yves; MADEC, Marc; Lepretre, Pascale; Vasseur, Olivier; Rigard-Cerison, Aude; Guedou, Benjamin; Houvenagel, Olivier; Epelbaum, David; Briant, Marie-Helene; Osmont, Robin; Elasri, Sofia; Barreyre, Gildas; Adam, Julien

    2017-09-01

    This study mainly aims at characterising and assessing the cut-off potential in the French industrial and tertiary sectors by providing qualitative as well as quantitative elements, and by highlighting the different mechanisms of valorisation of existing and currently developed cut-off. It also proposes a comparison of the French context with that of some foreign countries (notably United Kingdom, Japan, and some regions of the USA). Thus, it comprises an identification and analysis of cut-off mechanisms and practices, an assessment of technical and technical-economic cut-off sources in France, and a discussion of economic and organisational brakes and obstacles to cut-off developments

  10. Establishing pathological cut-offs for lateral ventricular volume expansion rates

    Directory of Open Access Journals (Sweden)

    Michael G. Dwyer

    Full Text Available Background: A percent brain volume change (PBVC cut-off of −0.4% per year has been proposed to distinguish between pathological and physiological changes in multiple sclerosis (MS. Unfortunately, standardized PBVC measurement is not always feasible on scans acquired outside research studies or academic centers. Percent lateral ventricular volume change (PLVVC is a strong surrogate measure of PBVC, and may be more feasible for atrophy assessment on real-world scans. However, the PLVVC rate corresponding to the established PBVC cut-off of −0.4% is unknown. Objective: To establish a pathological PLVVC expansion rate cut-off analogous to −0.4% PBVC. Methods: We used three complementary approaches. First, the original follow-up-length-weighted receiver operating characteristic (ROC analysis method establishing whole brain atrophy rates was adapted to a longitudinal ventricular atrophy dataset of 177 relapsing-remitting MS (RRMS patients and 48 healthy controls. Second, in the same dataset, SIENA PBVCs were used with non-linear regression to directly predict the PLVVC value corresponding to −0.4% PBVC. Third, in an unstandardized, real world dataset of 590 RRMS patients from 33 centers, the cut-off maximizing correspondence to PBVC was found. Finally, correspondences to clinical outcomes were evaluated in both datasets. Results: ROC analysis suggested a cut-off of 3.09% (AUC = 0.83, p < 0.001. Non-linear regression R2 was 0.71 (p < 0.001 and a − 0.4% PBVC corresponded to a PLVVC of 3.51%. A peak in accuracy in the real-world dataset was found at a 3.51% PLVVC cut-off. Accuracy of a 3.5% cut-off in predicting clinical progression was 0.62 (compared to 0.68 for PBVC. Conclusions: Ventricular expansion of between 3.09% and 3.51% on T2-FLAIR corresponds to the pathological whole brain atrophy rate of 0.4% for RRMS. A conservative cut-off of 3.5% performs comparably to PBVC for clinical outcomes. Keywords: Brain atrophy

  11. Metals attenuation in minerally-enhanced slurry walls

    International Nuclear Information System (INIS)

    Evans, J.C.; Prince, M.J.; Adams, T.L.

    1997-01-01

    In current practice, a soil-bentonite slurry trench cutoff wall is a mixture of water, soil, and bentonite that is designed to serve as a passive barrier to ground water and contaminant transport. This study evaluated the transformation of a passive slurry trench cutoff wall barrier to an active barrier system. Conventional soil-bentonite vertical barriers presently serve as passive barriers to contaminated ground water. An active barrier will not only fulfill the functions of the present passive barrier system, but also retard contaminant transport by adsorptive processes. Attapulgite, Na-chabazite, and Ca-chabazite were added to open-quotes activateclose quotes the conventional soil-bentonite backfill. Batch extraction tests were performed to determine the partitioning coefficients of cadmium and zinc between the liquid and solid phase when in contact with the backfill mixes. Batch extraction and mathematical modeling results demonstrate the ability of an active barrier to retard the transport of cadmium and zinc. The reactivity of the soil-bentonite vertical barrier depends heavily on the inorganic being adsorbed. The reactivity of the barrier also depends on the adsorptive capabilities of the clay minerals added to the conventional soil-bentonite vertical barrier. The results of laboratory studies suggest that passive barrier systems can be transformed to active systems. Further, the data suggests that although conventional soil-bentonite vertical barriers are presently designed as passive barriers, they already have adsorptive capacity associated with active barriers

  12. A new alternative in vertical barrier wall construction

    International Nuclear Information System (INIS)

    Rawl, G.F.

    1997-01-01

    A new proprietary vertical barrier wall system has been developed to revolutionize the construction process by eliminating many of the concerns of conventional installation method's with respect to performance, installation constraints and costs. Vertical barrier walls have been used in the environmental and construction industries for a variety of purposes, usually for cut-off or containment. The typical scenario involves a groundwater contamination problem, in which a vertical barrier wall is utilized to contain or confine the spread of contaminants below the ground surface. Conventional construction techniques have been adequate in many applications, but often fall short of their intended purposes due to physical constraints. In many instances, the economics of these conventional methods have limited the utilization of physical barrier walls. Polywall, the trade name for this new barrier wall technology, was subsequently developed to meet these needs and offer a number of distinct advantages in a variety of scenarios by maximizing confinement and minimizing installation costs. Polywall is constructed from chemically resistant high density polyethylene (HDPE) plastic. It has proven in a half-dozen projects to date to be the most cost-effective and technically sound approach to many containment situations. This paper will cover the development of the technology and will provide a brief synopsis of several installations

  13. 10 CFR 26.133 - Cutoff levels for drugs and drug metabolites.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for drugs and drug metabolites. 26.133... § 26.133 Cutoff levels for drugs and drug metabolites. Subject to the provisions of § 26.31(d)(3)(iii), licensees and other entities may specify more stringent cutoff levels for drugs and drug metabolites than...

  14. Critical test of isotropic periodic sum techniques with group-based cut-off schemes.

    Science.gov (United States)

    Nozawa, Takuma; Yasuoka, Kenji; Takahashi, Kazuaki Z

    2018-03-08

    Truncation is still chosen for many long-range intermolecular interaction calculations to efficiently compute free-boundary systems, macromolecular systems and net-charge molecular systems, for example. Advanced truncation methods have been developed for long-range intermolecular interactions. Every truncation method can be implemented as one of two basic cut-off schemes, namely either an atom-based or a group-based cut-off scheme. The former computes interactions of "atoms" inside the cut-off radius, whereas the latter computes interactions of "molecules" inside the cut-off radius. In this work, the effect of group-based cut-off is investigated for isotropic periodic sum (IPS) techniques, which are promising cut-off treatments to attain advanced accuracy for many types of molecular system. The effect of group-based cut-off is clearly different from that of atom-based cut-off, and severe artefacts are observed in some cases. However, no severe discrepancy from the Ewald sum is observed with the extended IPS techniques.

  15. Cut-off parameters in the one-dimensional two-fermion model

    International Nuclear Information System (INIS)

    Apostol, M.

    1982-07-01

    It is shown that the usual cut-off procedure (α cut-off parameter) employed in the boson representation of the fermion field opepators of the one-djmensional two-fermion model (TFM) is an incorrect one as the computator of the hermitean-conjugate field operators at the same space-point fails to fulfil a certain relationship which was pointed out long ago by Jordan. The complete form of the boson representation (including the zero-mode) of a single fermion field and the correct values of the cut-off parameter α is reviewed following Jordan and generalized to the TFM. The cut-off parameter α corresponds to a bandwidth cut-off and Jordan's boson representation is exact only in the limit α → 0. The additional zero-mode terms make the exact solution of the backscattering and umklapp scattering problem to be valid only if a supplementary condition is imposed on the coupling constants. Using the present bosonization technique all the inconsistencies of the TFM are removed. The one-particle Green's function and response functions of the Tomonaga-Luttinger model (TLM) are calculated and found to be identical with those obtained by direct diagram summation. The energy gap appearing in the spectrum of the TFM with backscattering and umklapp scattering for certain values of the coupling constants is shown to be proportional to the momentum transfer cut-off γ -1 which has to be kept finite while α goes to zero. Under such conditions the anticommunication relations and Jordan's commutator are invariant under the canonical transformation on the boson operators that diagonalizes the Hamiltonian of the TLM. The charge-density response function of the TFM with backscattering is perturbationally calculated up to the first order. The cut-off α -1 applies in the same way to terms which differ only by their spin indices in the expression of this response function. The charge-density response function is also evaluated at low frequencies for the exactly soluble TFM with

  16. Slurry walls and slurry trenches - construction quality control

    International Nuclear Information System (INIS)

    Poletto, R.J.; Good, D.R.

    1997-01-01

    Slurry (panel) walls and slurry trenches have become conventional methods for construction of deep underground structures, interceptor trenches and hydraulic (cutoff) barriers. More recently polymers mixed with water are used to stabilize the excavation instead of bentonite slurry. Slurry walls are typically excavated in short panel segments, 2 to 7 m (7 to 23 ft) long, and backfilled with structural materials; whereas slurry trenches are fairly continuous excavations with concurrent backfilling of blended soils, or cement-bentonite mixtures. Slurry trench techniques have also been used to construct interceptor trenches. Currently no national standards exist for the design and/or construction of slurry walls/trenches. Government agencies, private consultants, contractors and trade groups have published specifications for construction of slurry walls/trenches. These specifications vary in complexity and quality of standards. Some place excessive emphasis on the preparation and control of bentonite or polymer slurry used for excavation, with insufficient emphasis placed on quality control of bottom cleaning, tremie concrete, backfill placement or requirements for the finished product. This has led to numerous quality problems, particularly with regard to identification of key depths, bottom sediments and proper backfill placement. This paper will discuss the inspection of slurry wall/trench construction process, identifying those areas which require special scrutiny. New approaches to inspection of slurry stabilized excavations are discussed

  17. Extended BPH renormalization of cutoff scalar field theories

    International Nuclear Information System (INIS)

    Chalmers, G.

    1996-01-01

    We show through the use of diagrammatic techniques and a newly adapted BPH renormalization method that general momentum cutoff scalar field theories in four dimensions are perturbatively renormalizable. Weinberg close-quote s convergence theorem is used to show that operators in the Lagrangian with dimension greater than four, which are divided by powers of the cutoff, produce perturbatively only local divergences in the two-, three-, and four-point correlation functions. The naive use of the convergence theorem together with the BPH method is not appropriate for understanding the local divergences and renormalizability of these theories. We also show that the renormalized Green close-quote s functions are the same as in ordinary Φ 4 theory up to corrections suppressed by inverse powers of the cutoff. These conclusions are consistent with those of existing proofs based on the renormalization group. copyright 1996 The American Physical Society

  18. Normal Limits of Electrocardiogram and Cut-Off Values for Left ...

    African Journals Online (AJOL)

    Gender difference exists in some cut-off values for LVH. This study defined the normal limits for electrocardiographic variables for young adult Nigerians. Racial factor should be taken into consideration in interpretation of ECG. Keywords: Normal limits, Electrocardiogram, Cut-off values, Left ventricular hypertrophy, Young ...

  19. Holographic cutoff on inflationary universes

    International Nuclear Information System (INIS)

    Santos, Fabio M. de N.; Cunha, Bruno Carneiro da

    2011-01-01

    Full text: Cosmological Inflation has been widely accepted as the standard explanation of the onset of Big-Bang Cosmology. However, many critiques have been made about the lack of an account of quantum gravity degrees of freedom in cosmology. There is no definite consensus in the literature if we should consider the influence of pre-Plackian modes, for example, in inflationary models. We propose here a general approach to take quantum gravity into account by imposing a holographic cutoff on the number of states of cosmological theories. We apply the method to inflationary scalar field models coupled to a generic potential V (φ). This thermodynamic cutoff allow us to assess the relative volume of phase space which inflates for the particular model where V (φ) = m 2 φ 2 /2. The density of states of the model is defined by taking the coincidence limit of the Hadamard Green function G (1) and we use the point-splitting method to regulate the expression. Our conclusion is that inflation has probability very close to one. (author)

  20. Controls on cutoff formation along a tropical meandering river in the Amazon Basin

    Science.gov (United States)

    Ahmed, J.; Constantine, J. A.

    2016-12-01

    The termination of meander bends is an inherent part of the evolution of meandering rivers. Cutoffs are produced by one of two mechanisms: neck cutoffs occur when two adjacent meanders converge, while chute cutoffs are generated by flood-driven floodplain incision, resulting in a shorter, steeper channel path. Here we use an annually-resolved record of Landsat imagery, coupled with daily discharge data to assess the role of high-magnitude discharges (Q ≥ QBF) on cutoff formation along the Rio Beni, Bolivia. Our results suggest that despite numerous above-bankfull events, the dominant cutoff mechanism operating on the Beni is neck cutoff. Evaluating the formation of these cutoffs reveals that migration rates accelerate during years of high discharge, and eventually cause the migrating bends to breach. The density of floodplain vegetation and the medium into which the channel migrated was also responsible for the patterns of cutoff documented along this river. The presence of existing floodplain channels permitted the river to divert its flow along shorter courses thereby facilitating cutoff, and limiting sinuosity growth. Understanding the long-term evolution of meandering channels is important since their morphodynamics are responsible for the creation of highly biodiverse riparian habitats, as well as the store and release of alluvial material. Moreover, the interactions between discharge and the channel-floodplain system are integral for the functioning and long-term evolution of these landscapes, particularly in the face of global climate change.

  1. Defining obesity cut-off points for migrant South Asians.

    Directory of Open Access Journals (Sweden)

    Laura J Gray

    Full Text Available Body mass index (BMI and waist circumference (WC are used to define cardiovascular and type 2 diabetes risk. We aimed to derive appropriate BMI and WC obesity cut-off points in a migrant South Asian population.4688 White Europeans and 1333 South Asians resident in the UK aged 40-75 years inclusive were screened for type 2 diabetes. Principal components analysis was used to derive a glycaemia, lipid, and a blood pressure factor. Regression models for each factor, adjusted for age and stratified by sex, were used to identify BMI and WC cut-off points in South Asians that correspond to those defined for White Europeans.For South Asian males, derived BMI obesity cut-off points equivalent to 30.0 kg/m(2 in White Europeans were 22.6 kg/m(2 (95% Confidence Interval (95% CI 20.7 kg/m(2 to 24.5 kg/m(2 for the glycaemia factor, 26.0 kg/m(2 (95% CI 24.7 kg/m(2 to 27.3 kg/m(2 for the lipid factor, and 28.4 kg/m(2 (95% CI 26.5 kg/m(2 to 30.4 kg/m(2 for the blood pressure factor. For WC, derived cut-off points for South Asian males equivalent to 102 cm in White Europeans were 83.8 cm (95% CI 79.3 cm to 88.2 cm for the glycaemia factor, 91.4 cm (95% CI 86.9 cm to 95.8 cm for the lipid factor, and 99.3 cm (95% CI 93.3 cm to 105.2 cm for the blood pressure factor. Lower ethnicity cut-off points were seen for females for both BMI and WC.Substantially lower obesity cut-off points are needed in South Asians to detect an equivalent level of dysglycemia and dyslipidemia as observed in White Europeans. South Asian ethnicity could be considered as a similar level of risk as obesity (in White Europeans for the development of type 2 diabetes.

  2. Plasma density measurements on COMPASS-C tokamak from electron cyclotron emission cutoffs

    International Nuclear Information System (INIS)

    Chenna Reddy, D.; Edlington, T.

    1996-01-01

    Electron cyclotron emission (ECE) is a standard diagnostic in present day tokamak devices for temperature measurement. When the plasma density is high enough the emission at some frequencies is cut off. Of these cutoff frequencies, the first frequency to cut off depends on the shape of the density profile. If the density profile can be described by a few parameters, in some circumstances, this first cutoff frequency can be used to obtain two of these parameters. If more than two parameters are needed to describe the density profile, then additional independent measurements are required to find all the parameters. We describe a technique by which it is possible to obtain an analytical relation between the radius at which the first cutoff occurs and the profile parameters. Assuming that the shape of the profile does not change as the average density rises after the first cutoff, one can use the cutoffs at other frequencies to obtain the average density at the time of these cutoffs. The plasma densities obtained with this technique using the data from a 14 channel ECE diagnostic on COMPASS-C tokamak are in good agreement with those measured by a standard 2 mm interferometer. The density measurement using the ECE cutoffs is an independent measurement and requires only a frequency calibration of the ECE diagnostic. copyright 1996 American Institute of Physics

  3. Gravity Cutoff in Theories with Large Discrete Symmetries

    International Nuclear Information System (INIS)

    Dvali, Gia; Redi, Michele; Sibiryakov, Sergey; Vainshtein, Arkady

    2008-01-01

    We set an upper bound on the gravitational cutoff in theories with exact quantum numbers of large N periodicity, such as Z N discrete symmetries. The bound stems from black hole physics. It is similar to the bound appearing in theories with N particle species, though a priori, a large discrete symmetry does not imply a large number of species. Thus, there emerges a potentially wide class of new theories that address the hierarchy problem by lowering the gravitational cutoff due to the existence of large Z 10 32 -type symmetries

  4. The Hubble IR cutoff in holographic ellipsoidal cosmologies

    Energy Technology Data Exchange (ETDEWEB)

    Cataldo, Mauricio [Universidad del Bio-Bio, Departamento de Fisica, Facultad de Ciencias, Concepcion (Chile); Cruz, Norman [Grupo de Cosmologia y Gravitacion-UBB, Concepcion (Chile)

    2018-01-15

    It is well known that for spatially flat FRW cosmologies, the holographic dark energy disfavors the Hubble parameter as a candidate for the IR cutoff. For overcoming this problem, we explore the use of this cutoff in holographic ellipsoidal cosmological models, and derive the general ellipsoidal metric induced by a such holographic energy density. Despite the drawbacks that this cutoff presents in homogeneous and isotropic universes, based on this general metric, we developed a suitable ellipsoidal holographic cosmological model, filled with a dark matter and a dark energy components. At late time stages, the cosmic evolution is dominated by a holographic anisotropic dark energy with barotropic equations of state. The cosmologies expand in all directions in accelerated manner. Since the ellipsoidal cosmologies given here are not asymptotically FRW, the deviation from homogeneity and isotropy of the universe on large cosmological scales remains constant during all cosmic evolution. This feature allows the studied holographic ellipsoidal cosmologies to be ruled by an equation of state ω = p/ρ, whose range belongs to quintessence or even phantom matter. (orig.)

  5. Global warming precipitation accumulation increases above the current-climate cutoff scale.

    Science.gov (United States)

    Neelin, J David; Sahany, Sandeep; Stechmann, Samuel N; Bernstein, Diana N

    2017-02-07

    Precipitation accumulations, integrated over rainfall events, can be affected by both intensity and duration of the storm event. Thus, although precipitation intensity is widely projected to increase under global warming, a clear framework for predicting accumulation changes has been lacking, despite the importance of accumulations for societal impacts. Theory for changes in the probability density function (pdf) of precipitation accumulations is presented with an evaluation of these changes in global climate model simulations. We show that a simple set of conditions implies roughly exponential increases in the frequency of the very largest accumulations above a physical cutoff scale, increasing with event size. The pdf exhibits an approximately power-law range where probability density drops slowly with each order of magnitude size increase, up to a cutoff at large accumulations that limits the largest events experienced in current climate. The theory predicts that the cutoff scale, controlled by the interplay of moisture convergence variance and precipitation loss, tends to increase under global warming. Thus, precisely the large accumulations above the cutoff that are currently rare will exhibit increases in the warmer climate as this cutoff is extended. This indeed occurs in the full climate model, with a 3 °C end-of-century global-average warming yielding regional increases of hundreds of percent to >1,000% in the probability density of the largest accumulations that have historical precedents. The probabilities of unprecedented accumulations are also consistent with the extension of the cutoff.

  6. Global warming precipitation accumulation increases above the current-climate cutoff scale

    Science.gov (United States)

    Sahany, Sandeep; Stechmann, Samuel N.; Bernstein, Diana N.

    2017-01-01

    Precipitation accumulations, integrated over rainfall events, can be affected by both intensity and duration of the storm event. Thus, although precipitation intensity is widely projected to increase under global warming, a clear framework for predicting accumulation changes has been lacking, despite the importance of accumulations for societal impacts. Theory for changes in the probability density function (pdf) of precipitation accumulations is presented with an evaluation of these changes in global climate model simulations. We show that a simple set of conditions implies roughly exponential increases in the frequency of the very largest accumulations above a physical cutoff scale, increasing with event size. The pdf exhibits an approximately power-law range where probability density drops slowly with each order of magnitude size increase, up to a cutoff at large accumulations that limits the largest events experienced in current climate. The theory predicts that the cutoff scale, controlled by the interplay of moisture convergence variance and precipitation loss, tends to increase under global warming. Thus, precisely the large accumulations above the cutoff that are currently rare will exhibit increases in the warmer climate as this cutoff is extended. This indeed occurs in the full climate model, with a 3 °C end-of-century global-average warming yielding regional increases of hundreds of percent to >1,000% in the probability density of the largest accumulations that have historical precedents. The probabilities of unprecedented accumulations are also consistent with the extension of the cutoff. PMID:28115693

  7. Natural Covariant Planck Scale Cutoffs and the Cosmic Microwave Background Spectrum.

    Science.gov (United States)

    Chatwin-Davies, Aidan; Kempf, Achim; Martin, Robert T W

    2017-07-21

    We calculate the impact of quantum gravity-motivated ultraviolet cutoffs on inflationary predictions for the cosmic microwave background spectrum. We model the ultraviolet cutoffs fully covariantly to avoid possible artifacts of covariance breaking. Imposing these covariant cutoffs results in the production of small, characteristically k-dependent oscillations in the spectrum. The size of the effect scales linearly with the ratio of the Planck to Hubble lengths during inflation. Consequently, the relative size of the effect could be as large as one part in 10^{5}; i.e., eventual observability may not be ruled out.

  8. Performance Evaluation of Different d-Dimer Cutoffs in Bedridden Hospitalized Elderly Patients.

    Science.gov (United States)

    Kassim, Nevine A; Farid, Tamer M; Pessar, Shaimaa Abdelmalik; Shawkat, Salma A

    2017-11-01

    A rapid and accurate diagnosis of venous thromboembolism (VTE) in the elderly individuals represents a dilemma due to nonspecific clinical presentation, confusing laboratory results, and the hazards of radiological examination in this age-group. d-Dimer test is used mainly in combination with non-high clinical pretest probability (PTP) to exclude VTE. d-Dimer testing retains its sensitivity, however, its specificity decreases in the elderly individuals. Raising the cutoff level improves the specificity of the d-dimer test without compromising its sensitivity. The current study aimed to explore the reliability of higher d-dimer cutoff values for the diagnosis of asymptomatic VTE in a population of bedridden hospitalized elderly patients with non-high clinical PTP. This retrospective study included 252 bedridden hospitalized elderly patients (>65 years) who were admitted to the Ain shams University Specialized Hospital with non-high clinical probability and developed later reduced mobility; all underwent quantitation of d-dimer and Doppler examination. Considering the whole population (>65 years), the age-adjusted cutoff achieved the best performance in comparison with the conventional and receiver operating characteristic (ROC)-derived cutoffs. When stratified according to age, the age-adjusted cutoff showed the best performance in the age-group 65-70 and comparable performance with the ROC-derived cutoff in the age-group 71-80, however, its sensitivity compromised in those older than 80 years. In conclusion, it is recommended to use age-adjusted cutoff value of d-dimer together with the clinical probability score in elderly individuals (65-80 years).

  9. Guided mode cutoff in rare-earth doped rod-type PCFs

    DEFF Research Database (Denmark)

    Poli, F.; Cucinotta, A.; Passaro, D.

    2008-01-01

    Guided mode properties of rare-earth doped photonic crystal fibers are investigated as a function of the core refractive index, showing the possibility to obtain cutoff at low normalized wavelength.......Guided mode properties of rare-earth doped photonic crystal fibers are investigated as a function of the core refractive index, showing the possibility to obtain cutoff at low normalized wavelength....

  10. Predicting the cosmological constant with the scale-factor cutoff measure

    International Nuclear Information System (INIS)

    De Simone, Andrea; Guth, Alan H.; Salem, Michael P.; Vilenkin, Alexander

    2008-01-01

    It is well known that anthropic selection from a landscape with a flat prior distribution of cosmological constant Λ gives a reasonable fit to observation. However, a realistic model of the multiverse has a physical volume that diverges with time, and the predicted distribution of Λ depends on how the spacetime volume is regulated. A very promising method of regulation uses a scale-factor cutoff, which avoids a number of serious problems that arise in other approaches. In particular, the scale-factor cutoff avoids the 'youngness problem' (high probability of living in a much younger universe) and the 'Q and G catastrophes' (high probability for the primordial density contrast Q and gravitational constant G to have extremely large or small values). We apply the scale-factor cutoff measure to the probability distribution of Λ, considering both positive and negative values. The results are in good agreement with observation. In particular, the scale-factor cutoff strongly suppresses the probability for values of Λ that are more than about 10 times the observed value. We also discuss qualitatively the prediction for the density parameter Ω, indicating that with this measure there is a possibility of detectable negative curvature.

  11. Environmental sampling: Issues for the cut-off regime

    International Nuclear Information System (INIS)

    Fearey, B.L.

    1995-01-01

    The fissile material cut-off treaty (FMCT) initiative under the Conference on Disarmament mandate is envisioned to include certain aspects of environmental sampling and monitoring. One of the intents of this treaty is to bring certain non-NPT signatories (e.g., threshold states) under this treaty agreement along with the nuclear weapon states (NWSs). This paper provides a brief overview of some of the relevant issues that may be involved in the implementation and use of environmental monitoring for (1) verification of the cut-off regime declarations, (2) the detection of undeclared activities, and, (3) application in non-routine inspections. The intent is to provide backstopping information important for treaty negotiators. Specific issues addressed within this paper include signature sampling, differences in the proposed detection regime, potential signature integrators, specific examples and spoofing concerns. Many of these issues must be carefully considered and weighed in order to create a credibly verifiable inspection regime. Importantly, the cut-off treaty must enable nondiscriminatory implementation, while carefully assuring that nonproliferation treaty requirements are maintained (i.e., preventing unintentional release of critical weapons design information--potentially through environmental sampling and analysis)

  12. Community-Specific BMI Cutoff Points for South Indian Females

    Directory of Open Access Journals (Sweden)

    K. B. Kishore Mohan

    2011-01-01

    Full Text Available Objective. To analyze multiparameters related to total body composition, with specific emphasis on obesity in South Indian females, in order to derive community-specific BMI cutoff points. Patients and Methods. A total number of 87 females (of age 37.33±13.12 years from South Indian Chennai urban population participated in this clinical study. Body composition analysis and anthropometric measurements were acquired after conducting careful clinical examination. Results. BMI demonstrated high significance when normal group (21.02±1.47 kg/m2 was compared with obese group (29.31±3.95 kg/m2, <0.0001. BFM displayed high significance when normal group (14.92±4.28 kg was compared with obese group (29.94 ± 8.1 kg, <0.0001. Conclusion. Community-specific BMI cutoffs are necessary to assess obesity in different ethnic groups, and relying on WHO-based universal BMI cutoff points would be a wrong strategy.

  13. Classifying post-stroke fatigue: Optimal cut-off on the Fatigue Assessment Scale.

    Science.gov (United States)

    Cumming, Toby B; Mead, Gillian

    2017-12-01

    Post-stroke fatigue is common and has debilitating effects on independence and quality of life. The Fatigue Assessment Scale (FAS) is a valid screening tool for fatigue after stroke, but there is no established cut-off. We sought to identify the optimal cut-off for classifying post-stroke fatigue on the FAS. In retrospective analysis of two independent datasets (the '2015' and '2007' studies), we evaluated the predictive validity of FAS score against a case definition of fatigue (the criterion standard). Area under the curve (AUC) and sensitivity and specificity at the optimal cut-off were established in the larger 2015 dataset (n=126), and then independently validated in the 2007 dataset (n=52). In the 2015 dataset, AUC was 0.78 (95% CI 0.70-0.86), with the optimal ≥24 cut-off giving a sensitivity of 0.82 and specificity of 0.66. The 2007 dataset had an AUC of 0.83 (95% CI 0.71-0.94), and applying the ≥24 cut-off gave a sensitivity of 0.84 and specificity of 0.67. Post-hoc analysis of the 2015 dataset revealed that using only the 3 most predictive FAS items together ('FAS-3') also yielded good validity: AUC 0.81 (95% CI 0.73-0.89), with sensitivity of 0.83 and specificity of 0.75 at the optimal ≥8 cut-off. We propose ≥24 as a cut-off for classifying post-stroke fatigue on the FAS. While further validation work is needed, this is a positive step towards a coherent approach to reporting fatigue prevalence using the FAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. CUTOFF POINT OF THE PHASE ANGLE IN PRE-RADIOTHERAPY CANCER PATIENTS.

    Science.gov (United States)

    Souza Thompson Motta, Rachel; Alves Castanho, Ivany; Guillermo Coca Velarde, Luis

    2015-11-01

    malnutrition is a common complication for cancer patients. The phase angle (PA), direct measurement of bioelectrical impedance analysis (BIA), has been considered a predictor of body cell mass and prognostic indicator. Cutoff points for phase angle (PA) associated with nutritional risk in cancer patients have not been determined yet. assess the possibility of determining the cutoff point for PA to identify nutritional risk in pre-radiotherapy cancer patients. sample group: Patients from both genders diagnosed with cancer and sent for ambulatory radiotherapy. body mass index (BMI), percentage of weight loss (% WL), mid-arm circumference (MAC), triceps skinfold thickness (TST), mid-arm muscle circumference (MAMC), mid-arm muscle area (MAMA), score and categorical assessment obtained using the Patient-Generated Subjective Global Assessment (PG-SGA) form, PA and standardized phase angle (SPA). Kappa coefficient was used to test the degree of agreement between the diagnoses of nutritional risk obtained from several different methods of nutritional assessment. Cutoff points for the PA through anthropometric indicators and PG-SGA were determined by using Receiver Operating Characteristic (ROC) curves, and patient survival was analyzed with the Cox regression method. the cutoff points with the greatest discriminatory power were those obtained from BMI (5.2) and the categorical assessment of PG-SGA (5.4). The diagnosis obtained using these cutoff points showed a significant association with risk of death for the patients in the sample group. we recommend using the cutoff point 5.2 for the PA as a criterion for identifying nutritional risk in pre-radiotherapy cancer patients. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  15. The effect of magnetic field models on cosmic ray cutoff calculations

    International Nuclear Information System (INIS)

    Pfitzer, K.A.

    1979-01-01

    The inaccuracies in the 1974 Olson-Pfitzer model appeared to be the probable cause for discrepancies between the observed and calculated cosmic ray cutoff values. An improved version of the Olson-Pfitzer model is now available which includes the effects of the tilt of the earth's dipole axis and which has removed most of the problems encountered in the earlier model. The paper demonstrates that when this new accurate magnetic field model is used, the calculated and observed cutoff values agree with the experimental error without the need for invoking anomalous diffusion mechanisms. This tilt-dependent model also permits a study of cutoffs versus the tilt of the dipole axis

  16. 10 CFR 26.163 - Cutoff levels for drugs and drug metabolites.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for drugs and drug metabolites. 26.163... the Department of Health and Human Services § 26.163 Cutoff levels for drugs and drug metabolites. (a... testing of specimens to determine whether they are negative for the indicated drugs and drug metabolites...

  17. Hemoglobin cut-off values in healthy Turkish infants

    Institute of Scientific and Technical Information of China (English)

    Ahmet Arvas; Emel Gür; DurmuşDoğan

    2014-01-01

    Background: Anemia is a widespread public health problem associated with an increased risk of morbidity and mortality. This study was undertaken to determine the cut-off value of hemoglobin for infant anemia. Methods: A cross-sectional retrospective study was carried out at well-baby clinics of a tertiary care hospital. A total of 1484 healthy infants aged between 4 to 24 months were included in the study. The relationship of hemoglobin (Hb) levels with mother age, birth weight, weight gain rate, feeding, and gender was evaluated. Results: The Hb levels were assessed in four age groups (4 months, 6 months, 9-12 months, and 15-24 months) and the cut-off values of Hb were determined. Hb cut-off values (5th percentile for age) were detected as 97 g/L and 93 g/L at 4 months and 6 months, respectively. In older infants, the 5th percentile was 90.5 g/L and 93.4 g/L at 9-12 months and 15-24 months, respectively. The two values were lower than the World Health Organization criteria for anemia, which could partly due to the lack of information on iron status in our population. However, this difference highlights the need for further studies on normal Hb levels in healthy infants in developing countries. Hb levels of females were higher in all age groups; however, a statistically significant difference was found in gender in only 6 month-old infants. No statistically significant difference was found among Hb levels, mother's age, birth weight, weight gain rate, and nutritional status. Conclusion: Hb cut-off values in infants should be re-evaluated and be compatible with growth and development of children in that community.

  18. A self-consistent nonlinear theory of resistive-wall instability in a relativistic electron beam

    International Nuclear Information System (INIS)

    Uhm, H.S.

    1994-01-01

    A self-consistent nonlinear theory of resistive-wall instability is developed for a relativistic electron beam propagating through a grounded cylindrical resistive tube. The theory is based on the assumption that the frequency of the resistive-wall instability is lower than the cutoff frequency of the waveguide. The theory is concentrated on study of the beam current modulation directly related to the resistive-wall klystron, in which a relativistic electron beam is modulated at the first cavity and propagates downstream through the resistive wall. Because of the self-excitation of the space charge waves by the resistive-wall instability, a highly nonlinear current modulation of the electron beam is accomplished as the beam propagates downstream. A partial integrodifferential equation is obtained in terms of the initial energy modulation (ε), the self-field effects (h), and the resistive-wall effects (κ). Analytically investigating the partial integrodifferential equation, a scaling law of the propagation distance z m at which the maximum current modulation occurs is obtained. It is found in general that the self-field effects dominate over the resistive-wall effects at the beginning of the propagation. As the beam propagates farther downstream, the resistive-wall effects dominate. Because of a relatively large growth rate of the instability, the required tube length of the klystron is short for most applications

  19. Explaining the use of attribute cut-off values in decision making by means of involvement

    DEFF Research Database (Denmark)

    Peschel, Anne O.; Grebitus, Carola; Colson, Gregory

    2016-01-01

    evidence on consumers’ heterogeneous use of attribute cut-offs with a unique focus on the relationship with consumer involvement, a key component in consumer choice theory. Behavioral data from an online choice experiment on beef steak employing shelf simulations are combined with questions defining...... a latent class model identifies several key consumer segments (e.g., a price sensitive group) based on their choice behavior and reveals that the relationship between involvement, cut-off use and cut-off violations is not uniform across consumer segments....... respondents’ attribute cut-off values and their validated Personal Involvement Inventory (PII). Evidence from the analysis indicates that consumers who are highly involved are more likely to exhibit attribute cut-off values and are less likely to violate their cut-off values. Further investigation using...

  20. Raised BMI cut-off for overweight in Greenland Inuit--a review.

    Science.gov (United States)

    Andersen, Stig; Fleischer Rex, Karsten; Noahsen, Paneeraq; Sørensen, Hans Christian Florian; Mulvad, Gert; Laurberg, Peter

    2013-01-01

    Obesity is associated with increased morbidity and premature death. Obesity rates have increased worldwide and the WHO recommends monitoring. A steep rise in body mass index (BMI), a measure of adiposity, was detected in Greenland from 1963 to 1998. Interestingly, the BMI starting point was in the overweight range. This is not conceivable in a disease-free, physically active, pre-western hunter population. This led us to reconsider the cut-off point for overweight among Inuit in Greenland. We found 3 different approaches to defining the cut-off point of high BMI in Inuit. First, the contribution to the height by the torso compared to the legs is relatively high. This causes relatively more kilograms per centimetre of height that increases the BMI by approximately 10% compared to Caucasian whites. Second, defining the cut-off by the upper 90-percentile of BMI from height and weight in healthy young Inuit surveyed in 1963 estimated the cut-off point to be around 10% higher compared to Caucasians. Third, if similar LDL-cholesterol and triglycerides are assumed for a certain BMI in Caucasians, the corresponding BMI in Inuit in both Greenland and Canada is around 10% higher. However, genetic admixture of Greenland Inuit and Caucasian Danes will influence this difference and hamper a clear distinction with time. Defining overweight according to the WHO cut-off of a BMI above 25 kg/m(2) in Greenland Inuit may overestimate the number of individuals with elevated BMI.

  1. Surface effect theory in binary alloys: surfaces with cut-off

    International Nuclear Information System (INIS)

    Kumar, V.; Silva, C.E.T.G. da; Moran-Lopez, J.L.

    1981-01-01

    A surface effect theory in binary alloys which ore ordered with surfaces with cut-off is presented. This theory is based in a model of pair interaction between first neighbours and includes long and short range effects. The (120) surface with sup(-) (110) monoatomic cut-off and terrace in the (110) planes of an alloy with body centered cubic structure is presented as example. Results for the concentrations in all the different surface sites are given. (L.C.) [pt

  2. A new D-dimer cutoff in bedridden hospitalized elderly patients.

    Science.gov (United States)

    Granziera, Serena; Rechichi, Alfonsina; De Rui, Marina; De Carlo, Paola; Bertozzo, Giulia; Marigo, Lucia; Nante, Giovanni; Manzato, Enzo

    2013-03-01

    Asymptomatic deep vein thrombosis (DVT) and pulmonary embolism are leading causes of morbidity following the hospitalization of elderly people. The diagnosis of DVT is supported by the D-dimer laboratory assay. The concentration of D-dimer increases in patients with DVT, but may be high in other conditions too (i.e. cancer, infections and inflammation). Old age coincides with a physiological increase in D-dimer values, and that is why D-dimer assay in the elderly is characteristically highly sensitive but scarcely specific. The aim of our study was to explore the reliability of different D-dimer cutoffs for the diagnosis of asymptomatic DVT in a population of bedridden hospitalized elderly patients. We studied 199 patients who were a mean 86.3 ± 6.7 years old. All participants underwent lower limb Doppler ultrasound (DUS) and D-dimer venous blood sampling on admission. In our cohort, the usual cutoff proved highly sensitive (100%), but its specificity was very poor (20.1%). To find a higher cutoff that could improve the method's specificity, we analyzed our data using a receiver operating characteristic curve analysis. The resulting D-dimer cutoff of 492 μg/l enabled us to retain the same sensitivity while improving the test's specificity to 39.1%, with a consequent improvement in its positive predictive value and accuracy. In addition to improving the method's reliability, this result may be helpful in clinical practice, in both medical wards and nursing homes. By adopting a cutoff of 492 μg/l, clinicians could significantly increase the proportion of older patients in whom DVT can be safely ruled out, reducing referrals for DUS and administration of heparin, with consequent clinical, practical and economic advantages.

  3. Observation of frequency cutoff for self-excited dust acoustic waves

    Science.gov (United States)

    Nosenko, V.; Zhdanov, S. K.; Morfill, G. E.; Kim, S.-H.; Heinrich, J.; Merlino, R. L.

    2009-11-01

    Complex (dusty) plasmas consist of fine solid particles suspended in a weakly ionized gas. Complex plasmas are excellent model systems to study wave phenomena down to the level of individual ``atoms''. Spontaneously excited dust acoustic waves were observed with high temporal resolution in a suspension of micron-size kaolin particles in a dc discharge in argon. Wave activity was found at frequencies as high as 400 Hz. At high wave numbers, the wave dispersion relation was acoustic-like (frequency proportional to wave number). At low wave numbers, the wave frequency did not tend to zero, but reached a cutoff frequency fc instead. The value of fc declined with distance from the anode. We propose a simple model that explains the observed cutoff by particle confinement in plasma. The existence of a cutoff frequency is very important for the propagation of waves: the waves excited above fc are propagating, and those below fc are evanescent.

  4. Effects of a strict cutoff on Quantum Field Theory

    International Nuclear Information System (INIS)

    Sturnfield, J.F.

    1987-01-01

    Standard Quantum Field Theory has a number of integrals which are infinite. Although these are eliminated for some cases by renormalization, this aspect of the theory is not fully satisfactory. A number of theories with fundamental lengths have been introduced as alternatives and it would be useful to be able to distinguish between them. In particular, the effects that a strict cutoff would have on Quantum Field Theory is studied. It is noted that care must be taken in the method used to apply a strict cutoff. This lead to considering a theory where the cutoffs are defined by restricting each internal line. This theory is only piece-wise analytic. The resulting scattering matrix is frame dependent, yet the theory still satisfies the special relativity view that all frames are subjectively identical. The renormalization of this theory is finite. The change in mass from the electron self-energy will be a spinor operator. The main distinctions of this theory from standard theory will occur at super high energies. New poles and resonances which arise from new endpoint singularities will be found. The locations of these singularities will be frame dependent. Some of these singularities will correspond to creations or interactions of the normal particles with tachyons. It will be shown that for the one loop diagram, the form of the cutoff singularities are closely related to the standard singularities. When there is more than one loop, there can appear some new type of behavior. In particular, a cube root type of behavior in the two loop self-energy diagram will be found. Also the asymptotic behavior of the ladder diagram is studied

  5. Large cutoff effects of dynamical Wilson fermions

    International Nuclear Information System (INIS)

    Sommer, R.; Hoffmann, R.; Knechtli, F.; Rolf, J.; Wolff, U.; Wetzorke, I.

    2003-09-01

    We present and discuss results for cutoff effects in the PCAC masses and the mass dependence of r 0 for full QCD and various fermion actions. Our discussion of how one computes mass dependences - here of r 0 - is also relevant for comparisons with chiral perturbation theory. (orig.)

  6. Cut-off frequencies of circumferential horizontal shear waves in various functionally graded cylinder shells.

    Science.gov (United States)

    Shen, Xiaoqin; Ren, Dawei; Cao, Xiaoshan; Wang, Ji

    2018-03-01

    In this study, cut-off frequencies of the circumferential SH waves in functionally graded piezoelectric-piezomagnetic material (FGPPM) cylinder shells with traction free, electrical and magnetic open boundary conditions are investigated analytically. The Wentzel-Kramers-Brillouin (WKB) method is employed for solving differential equations with variable coefficients for general cases. For comparison, Bessel functions and Kummer functions are used for solving cut-off frequency problems in homogenous and ideal FGPPM cylinder shells. It is shown that the WKB solution for the cut-off frequencies has good precise. The set of cut-off frequencies is a series of approximate arithmetic progressions, for which the difference is a function of the density and the effective elastic parameter. The relationship between the difference and the gradient coefficient is described. These results provide theoretical guidance for the non-destructive evaluation of curved shells based on the cut-off frequencies. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Waist-to-height: cutoff matters in predicting metabolic syndrome in Mexican children.

    Science.gov (United States)

    Elizondo-Montemayor, Leticia; Serrano-González, Mónica; Ugalde-Casas, Patricia A; Bustamante-Careaga, Humberto; Cuello-García, Carlos

    2011-06-01

    Body-mass index (BMI), waist circumference (WC), and, recently, waist-to-height ratio (WHtR) have been proposed as clinical indexes to identify children at cardiometabolic risk. The aim was to identify the usefulness of WHtR cutoffs, WC, and BMI as predictors of metabolic syndrome in Mexican children, according to BMI z-scores, and the severity of obesity to cardiometabolic risk factors and metabolic syndrome. This was a cross-sectional study of 214 overweight/obese and 47 normal-weight Mexican children 6-12 years old. Children were divided in groups according to BMI z-scores. Anthropometric and biochemical measurements were determined. Receiver-operating characteristic (ROC) curves and areas under the curves were calculated to compare the abilities of the anthropometric measurements to predict metabolic syndrome. The overall prevalence of metabolic syndrome was 23.3%, ranging from 11.0% in the overweight group to 73.9% in the severely obese one. Children with metabolic syndrome had significantly higher WHtR, WC, BMI, percentage of body fat, triglycerides, total cholesterol, low-density lipoprotein cholesterol (LDL-C), systolic and diastolic blood pressure, and lower high-density lipoprotein cholesterol (HDL-C). A WHtR cutoff point of 0.59 from the ROC curve was identified as strong predictor of metabolic syndrome in our population, whereas a cutoff of 0.5 showed very poor specificity (22.7%). WC predicted metabolic syndrome as well. Cutoff values for WHtR make a difference in predicting metabolic syndrome. A cutoff of 0.59 for WHtR strongly predicted metabolic syndrome; it might be a simpler to use screening tools and counters for short people. Further studies are required to determine the cutoff points for an accurate prediction, because there are few in children and none in Mexico.

  8. Analysis of cutoff frequency in a one-dimensional superconductor-metamaterial photonic crystal

    International Nuclear Information System (INIS)

    Aly, Arafa H; Aghajamali, Alireza; Elsayed, Hussein A.; Mobarak, Mohamed

    2016-01-01

    Highlights: • Our results show that the appearance of the cutoff frequency, below which the incident electromagnetic waves cannot propagate in the structure. We demonstrate that the cutoff frequency shows an upward trend as the thickness of the superconductor layer as well as the thickness of the metamaterial increase. • The cutoff frequency can be tuned by the operating temperature. Our structures are good candidates for many optical devices such as optical filters, switches, temperature controlled optical shutter, and among photoelectronic applications in gigahertz. - Abstract: In this paper, using the two-fluid model and the characteristic matrix method, we investigate the transmission characteristics of the one-dimensional photonic crystal. Our structure composed of the layers of low-temperature superconductor material (NbN) and double-negative metamaterial. We target studying the effect of many parameters such as the thickness of the superconductor material, the thickness of the metamaterial layer, and the operating temperature. We show that the cut-off frequency can be tuned efficiently by the operating temperature as well as the thicknesses of the constituent materials.

  9. Effect of porous media of the stenosed artery wall to the coronary physiological diagnostic parameter: a computational fluid dynamic analysis.

    Science.gov (United States)

    Govindaraju, Kalimuthu; Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Viswanathan, Girish N; Badarudin, A; Salman Ahmed, N J

    2014-04-01

    Functional assessment of a coronary artery stenosis severity is generally assessed by fractional flow reserve (FFR), which is calculated from pressure measurements across the stenosis. The purpose of this study is to investigate the effect of porous media of the stenosed arterial wall on this diagnostic parameter. To understand the role of porous media on the diagnostic parameter FFR, a 3D computational simulations of the blood flow in rigid and porous stenotic artery wall models are carried out under steady state and transient conditions for three different percentage area stenoses (AS) corresponding to 70% (moderate), 80% (intermediate), and 90% (severe). Blood was modeled as a non Newtonian fluid. The variations of pressure drop across the stenosis and diagnostic parameter were studied in both models. The FFR decreased in proportion to the increase in the severity of the stenosis. The relationship between the percentage AS and the FFR was non linear and inversely related in both the models. The cut-off value of 0.75 for FFR was observed at 81.89% AS for the rigid artery model whereas 83.61% AS for the porous artery wall model. This study demonstrates that the porous media consideration on the stenotic arterial wall plays a substantial role in defining the cut-off value of FFR. We conclude that the effect of porous media on FFR, could lead to misinterpretation of the functional severity of the stenosis in the region of 81.89 %-83.61% AS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. The operation cutoff frequency of high electron mobility transistor measured by terahertz method

    International Nuclear Information System (INIS)

    Zhu, Y. M.; Zhuang, S. L.

    2014-01-01

    Commonly, the cutoff frequency of high electron mobility transistor (HEMT) can be measured by vector network analyzer (VNA), which can only measure the sample exactly in low frequency region. In this paper, we propose a method to evaluate the cutoff frequency of HEMT by terahertz (THz) technique. One example shows the cutoff frequency of our HEMT is measured at ∼95.30 GHz, which is reasonable agreement with that estimated by VNA. It is proved THz technology a potential candidate for the substitution of VNA for the measurement of high-speed devices even up to several THz.

  11. Optimised cut-off function for Tersoff-like potentials for a BN nanosheet: a molecular dynamics study

    International Nuclear Information System (INIS)

    Kumar, Rajesh; Rajasekaran, G; Parashar, Avinash

    2016-01-01

    In this article, molecular dynamics based simulations were carried out to study the tensile behaviour of boron nitride nanosheets (BNNSs). Four different sets of Tersoff potential parameters were used in the simulations for estimating the interatomic interactions between boron and nitrogen atoms. Modifications were incorporated in the Tersoff cut-off function to improve the accuracy of results with respect to fracture stress, fracture strain and Young’s modulus. In this study, the original cut-off function was optimised in such a way that small and large cut-off distances were made equal, and hence a single cut-off distance was used with all sets of Tersoff potential parameters. The single value of cut-off distance for the Tersoff potential was chosen after analysing the potential energy and bond forces experienced by boron and nitrogen atoms subjected to bond stretching. The simulations performed with the optimised cut-off function help in identifying the Tersoff potential parameters that reproduce the experimentally evaluated mechanical behaviour of BNNSs. (paper)

  12. Can computed tomography aid in diagnosis of intramural hematomas of the intestinal wall?

    Science.gov (United States)

    Ulusan, Serife; Pekoz, Burcak; Sariturk, Cagla

    2015-12-01

    We sought to use computed tomography (CT) data to support the correct differential diagnosis of patients with spontaneous intramural hematomas of the gastrointestinal tract, to aid in the clinical management of those using oral anticoagulants. Patient data were retrospectively analyzed and patients were divided into two groups. The first group contained 10 patients (5 females, 5 males, median age 65 years [range 35-79 years]) who had been diagnosed with spontaneous intramural hematomas of the gastrointestinal tract. The second group contained nine patients (5 females, 4 males, median age 41 years [range 24-56 years]) who exhibited intestinal wall thickening on CT, and who had been diagnosed with ulcerative colitis, Crohn's disease, ameboma, and lymphoma. The enhancement patterns in the CT images of the two groups were compared by an experienced and inexperienced radiologist. The differences in values were subjected to ROC analysis. Inter-observer variability was excellent (0.84) when post-contrast CT images were evaluated, as were the subtraction values (0.89). The subtracted values differed significantly between the two groups (p=0.0001). A cutoff of +31.5 HU was optimal in determining whether a hematoma was or was not present. Contrast enhancement of an intestinal wall hematoma is less than that of other intestinal wall pathologies associated with increased wall thickness. If the post-contrast enhancement of a thickened intestinal wall is less than +31.5 HU, a wall hematoma is possible. © Acta Gastro-Enterologica Belgica.

  13. Histogram plots and cutoff energies for nuclear discrete levels

    International Nuclear Information System (INIS)

    Belgya, T.; Molnar, G.; Fazekas, B.; Oestoer, J.

    1997-05-01

    Discrete level schemes for 1277 nuclei, from 6 Li through 251 Es, extracted from the Evaluated Nuclear Structure Data File were analyzed. Cutoff energies (U max ), indicating the upper limit of level scheme completeness, were deduced from the inspection of histograms of the cumulative number of levels. Parameters of the constant-temperature level density formula (nuclear temperature T and energy shift U 0 ) were obtained by means of the least square fit of the formula to the known levels below cutoff energy. The results are tabulated for all 1277 nuclei allowing for an easy and reliable application of the constant-temperature level density approach. A complete set of cumulative plots of discrete levels is also provided. (author). 5 figs, 2 tabs

  14. Raised BMI cut-off for overweight in Greenland Inuit – a review

    Science.gov (United States)

    Andersen, Stig; Fleischer Rex, Karsten; Noahsen, Paneeraq; Sørensen, Hans Christian Florian; Mulvad, Gert; Laurberg, Peter

    2013-01-01

    Background Obesity is associated with increased morbidity and premature death. Obesity rates have increased worldwide and the WHO recommends monitoring. A steep rise in body mass index (BMI), a measure of adiposity, was detected in Greenland from 1963 to 1998. Interestingly, the BMI starting point was in the overweight range. This is not conceivable in a disease-free, physically active, pre-western hunter population. Objective This led us to reconsider the cut-off point for overweight among Inuit in Greenland. Design and findings We found 3 different approaches to defining the cut-off point of high BMI in Inuit. First, the contribution to the height by the torso compared to the legs is relatively high. This causes relatively more kilograms per centimetre of height that increases the BMI by approximately 10% compared to Caucasian whites. Second, defining the cut-off by the upper 90-percentile of BMI from height and weight in healthy young Inuit surveyed in 1963 estimated the cut-off point to be around 10% higher compared to Caucasians. Third, if similar LDL-cholesterol and triglycerides are assumed for a certain BMI in Caucasians, the corresponding BMI in Inuit in both Greenland and Canada is around 10% higher. However, genetic admixture of Greenland Inuit and Caucasian Danes will influence this difference and hamper a clear distinction with time. Conclusion Defining overweight according to the WHO cut-off of a BMI above 25 kg/m2 in Greenland Inuit may overestimate the number of individuals with elevated BMI. PMID:23986904

  15. Raised BMI cut-off for overweight in Greenland Inuit – a review

    Directory of Open Access Journals (Sweden)

    Stig Andersen

    2013-08-01

    Full Text Available Background. Obesity is associated with increased morbidity and premature death. Obesity rates have increased worldwide and the WHO recommends monitoring. A steep rise in body mass index (BMI, a measure of adiposity, was detected in Greenland from 1963 to 1998. Interestingly, the BMI starting point was in the overweight range. This is not conceivable in a disease-free, physically active, pre-western hunter population. Objective. This led us to reconsider the cut-off point for overweight among Inuit in Greenland. Design and findings. We found 3 different approaches to defining the cut-off point of high BMI in Inuit. First, the contribution to the height by the torso compared to the legs is relatively high. This causes relatively more kilograms per centimetre of height that increases the BMI by approximately 10% compared to Caucasian whites. Second, defining the cut-off by the upper 90-percentile of BMI from height and weight in healthy young Inuit surveyed in 1963 estimated the cut-off point to be around 10% higher compared to Caucasians. Third, if similar LDL-cholesterol and triglycerides are assumed for a certain BMI in Caucasians, the corresponding BMI in Inuit in both Greenland and Canada is around 10% higher. However, genetic admixture of Greenland Inuit and Caucasian Danes will influence this difference and hamper a clear distinction with time. Conclusion. Defining overweight according to the WHO cut-off of a BMI above 25 kg/m2 in Greenland Inuit may overestimate the number of individuals with elevated BMI.

  16. Nonperturbative bounds on in cutoff (lambdaphi/sup n/)/sub d/ field theory

    International Nuclear Information System (INIS)

    Doering, C.R.

    1985-01-01

    Stochastic quantization is used to obtain upper and lower bounds on the vacuum expectation value of phi/sup n/ in a cutoff lambdaphi/sup n/ scalar theory in d dimensions. These determine the behavior of as the cutoff is removed. The results are given by formulas which depend on whether the values of n and d define a perturbatively superrenormalizable, strictly renormalizable, or nonrenormalizable theory

  17. Systematic review of the evidence for Trails B cut-off scores in assessing fitness-to-drive.

    Science.gov (United States)

    Roy, Mononita; Molnar, Frank

    2013-01-01

    Fitness-to-drive guidelines recommend employing the Trail Making B Test (a.k.a. Trails B), but do not provide guidance regarding cut-off scores. There is ongoing debate regarding the optimal cut-off score on the Trails B test. The objective of this study was to address this controversy by systematically reviewing the evidence for specific Trails B cut-off scores (e.g., cut-offs in both time to completion and number of errors) with respect to fitness-to-drive. Systematic review of all prospective cohort, retrospective cohort, case-control, correlation, and cross-sectional studies reporting the ability of the Trails B to predict driving safety that were published in English-language, peer-reviewed journals. Forty-seven articles were reviewed. None of the articles justified sample sizes via formal calculations. Cut-off scores reported based on research include: 90 seconds, 133 seconds, 147 seconds, 180 seconds, and Trails B cut-offs of 3 minutes or 3 errors (the '3 or 3 rule'). Major methodological limitations of this body of research were uncovered including (1) lack of justification of sample size leaving studies open to Type II error (i.e., false negative findings), and (2) excessive focus on associations rather than clinically useful cut-off scores.

  18. Cutoff dependence in lattice phi44 theory

    International Nuclear Information System (INIS)

    Symanzik, K.

    1979-11-01

    The author discusses corrections to the high temperature expansion of the lattice phi 4 4 theory in 4 + epsilon dimensions using the renormalization group. He works with vertex functions, whose expansion is derived from an effective Lagrangian for large-cutoff behaviour. He concludes that the numerical phi 4 4 results offer a test of the idea of asymptotic freedom. (HSI)

  19. Azimuth cut-off model for significant wave height investigation along coastal water of Kuala Terengganu, Malaysia

    Science.gov (United States)

    Marghany, Maged; Ibrahim, Zelina; Van Genderen, Johan

    2002-11-01

    The present work is used to operationalize the azimuth cut-off concept in the study of significant wave height. Three ERS-1 images have been used along the coastal waters of Terengganu, Malaysia. The quasi-linear transform was applied to map the SAR wave spectra into real ocean wave spectra. The azimuth cut-off was then used to model the significant wave height. The results show that azimuth cut-off varied with the different period of the ERS-1 images. This is because of the fact that the azimuth cut-off is a function of wind speed and significant wave height. It is of interest to find that the significant wave height modeled from azimuth cut-off is in good relation with ground wave conditions. It can be concluded that ERS-1 can be used as a monitoring tool in detecting the significant wave height variation. The azimuth cut-off can be used to model the significant wave height. This means that the quasi-linear transform could be a good application to significant wave height variation during different seasons.

  20. A novel cutoff for the waist-to-height ratio predicting metabolic syndrome in young American adults

    Directory of Open Access Journals (Sweden)

    Adam D. Bohr

    2016-04-01

    Full Text Available Abstract Background Recent studies have shown the enhanced diagnostic capability of the waist-to-height ratio (WHtR over BMI. However, while a structured cutoff hierarchy has been established for BMI, a rigorous analysis to define individuals as obese using the WHtR has not been performed on a sample of American adults. This study attempts to establish a cutoff for the WHtR using metabolic syndrome as the outcome. Methods The study sample consisted of individuals that were part of the National Longitudinal Study of Adolescent Health (Add Health. The final sample for analysis consisted of 7 935 participants (3 469 males, 4 466 females that were complete respondents for the variables of interest at Wave IV. The participants ranged from 24.55-33.60 years. Weighted and unweighted receiver operator characteristics (ROC analyses were performed predicting metabolic syndrome from the WHtR. Cutoffs were chosen using the Youden index. The derived cutoffs were validated by logistic regression analysis on the Add Health participants and an external sample of 1 236 participants from the National Health and Nutrition Examination Survey (NHANES. Results The ROC analysis resulted in a WHtR cutoff of 0.578 (Youden Index = 0.50 for the full sample of complete respondents, 0.578 (Youden Index = 0.55 for males only, and 0.580 (Youden Index = 0.50 for females only. The area under the curve was 0.798 (95 % CI (0.788, 0.809 for the full sample of complete respondents, 0.833 (95 % CI (0.818, 0.848 for males only, and 0.804 (95 % CI (0.791, 0.818 for females only. Participants in the validation sample with a WHtR greater than the derived cutoff were more likely (Odds Ratio = 9.8, 95 % CI (6.2, 15.3 to have metabolic syndrome than those that were not. Conclusion A WHtR cutoff of 0.580 is optimal for discriminating individuals with metabolic syndrome in two nationally representative samples of young adults. This cutoff is an improvement over a

  1. Age-adjusted high-sensitivity troponin T cut-off value for risk stratification of pulmonary embolism.

    Science.gov (United States)

    Kaeberich, Anja; Seeber, Valerie; Jiménez, David; Kostrubiec, Maciej; Dellas, Claudia; Hasenfuß, Gerd; Giannitsis, Evangelos; Pruszczyk, Piotr; Konstantinides, Stavros; Lankeit, Mareike

    2015-05-01

    High-sensitivity troponin T (hsTnT) helps in identifying pulmonary embolism patients at low risk of an adverse outcome. In 682 normotensive pulmonary embolism patients we investigate whether an optimised hsTnT cut-off value and adjustment for age improve the identification of patients at elevated risk. Overall, 25 (3.7%) patients had an adverse 30-day outcome. The established hsTnT cut-off value of 14 pg·mL(-1) retained its high prognostic value (OR (95% CI) 16.64 (2.24-123.74); p=0.006) compared with the cut-off value of 33 pg·mL(-1) calculated by receiver operating characteristic analysis (7.14 (2.64-19.26); pvalue of 45 pg·mL(-1) but not the established cut-off value of 14 pg·mL(-1) predicted an adverse outcome. An age-adjusted hsTnT cut-off value (≥14 pg·mL(-1) for patients aged risk (12.4% adverse outcome). Risk assessment of normotensive pulmonary embolism patients was improved by the introduction of an age-adjusted hsTnT cut-off value. A three-step approach helped identify patients at higher risk of an adverse outcome who might benefit from advanced therapy. Copyright ©ERS 2015.

  2. Determination of a saliva cotinine cut-off to distinguish pregnant smokers from pregnant non-smokers

    DEFF Research Database (Denmark)

    Hegaard, Hanne K; Kjaergaard, Hanne; Møller, Lars F

    2007-01-01

    Objective validation of smoking status is necessary. Earlier studies have used saliva cotinine concentrations between 14.2 and 30 ng/ml as cut-off values to distinguish pregnant smokers from non-smokers. However, these cut-offs derive from studies including men and non-pregnant women....... This constitutes a problem, as recent studies have reported an accelerated metabolism in pregnant smokers. The aim of this study was to determine the optimum cut-off cotinine level distinguishing pregnant smokers from pregnant non-smokers....

  3. Geomagnetic-cutoff distribution functions for use in estimating detector response to neutrinos of atmospheric origin

    International Nuclear Information System (INIS)

    Cooke, D.J.

    1983-01-01

    A procedure has been developed for deriving functions which characterize the effect of geomagnetic cutoffs on the charged primary cosmic rays that give rise to neutrinos arriving in any given direction at specified points on or in the earth. These cutoff distribution functions, for use in atmospheric-neutrino flux calculations, have been determined for eight nucleon-decay--experiment sites, by use of a technique which employs the Stormer cutoff expression, and which assumes collinear motion of neutrino and parent primary

  4. Enhanced CT perfusion cut-off sign in midgut volvulus

    International Nuclear Information System (INIS)

    Henesch, Stephen M.; Jaramillo, Diego M.; Nance, Michael L.

    2006-01-01

    We present a case of malrotation with midgut volvulus in an infant in which we discovered a unique CT sign called the perfusion cut-off sign. We hope this case will help establish this crucial diagnosis in other cases. (orig.)

  5. Enhanced CT perfusion cut-off sign in midgut volvulus

    Energy Technology Data Exchange (ETDEWEB)

    Henesch, Stephen M.; Jaramillo, Diego M. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nance, Michael L. [Children' s Hospital of Philadelphia, Department of Surgery, Philadelphia, PA (United States)

    2006-04-15

    We present a case of malrotation with midgut volvulus in an infant in which we discovered a unique CT sign called the perfusion cut-off sign. We hope this case will help establish this crucial diagnosis in other cases. (orig.)

  6. Minority game with arbitrary cutoffs

    Science.gov (United States)

    Johnson, N. F.; Hui, P. M.; Zheng, Dafang; Tai, C. W.

    1999-07-01

    We study a model of a competing population of N adaptive agents, with similar capabilities, repeatedly deciding whether to attend a bar with an arbitrary cutoff L. Decisions are based upon past outcomes. The agents are only told whether the actual attendance is above or below L. For L∼ N/2, the game reproduces the main features of Challet and Zhang's minority game. As L is lowered, however, the mean attendances in different runs tend to divide into two groups. The corresponding standard deviations for these two groups are very different. This grouping effect results from the dynamical feedback governing the game's time-evolution, and is not reproduced if the agents are fed a random history.

  7. Effect of local perturbations of the geomagnetic field on cosmic ray cutoff rigidities at Jungfraujoch and Kiel

    International Nuclear Information System (INIS)

    Flueckiger, E.O.; Smart, D.F.; Shea, M.A.

    1983-01-01

    We have investigated the effect of local perturbations of the geomagnetic field on the vertical cosmic ray cutoff rigidities at Jungfraujoch and Kiel as representative mid-latitude neutron monitor stations. The main, effective, and Stoermer vertical cutoff rigidities and their changes were determined by utilizing the trajectory-tracing technique in a magnetic field which is modeled as a simple dipole field to which the disturbance field is superposed. It was found that the cosmic ray cutoff rigidities are most sensitive to variations of the z component of the geomagnetic field at geomagnetic latitudes -20 0 0 and at longitudes within 90 0 to the east of these northern hemisphere stations. Furthermore, cutoff rigidity variations at Kiel are predominantly due to changes of the geomagnetic field within geocentric distances 2.5R/sub E/< r<6R/sub E/, whereas at Jungfraujoch changes in cutoff rigidities are caused almost exclusively by magnetic disturbances within 1R/sub E/< r<4.5R/sub E/. For both locations the dependence of the main, effective, and Stoermer vertical cutoff rigidities on the radial, latitudinal and longitudinal structure of the magnetic perturbations is given explicitly. The results are discussed with respect to the theory by Treiman (1953) describing the effect of a ring current on cosmic ray cutoff rigidities. It is also shown that for the analysis of the characteristic properties of the correlation between cutoff rigidity variations and specific geomagnetic perturbations the rigidity corresponding to the first ''discontinuity band'' of the rigidity spectrum is an extremely useful parameter

  8. Elongation cutoff technique armed with quantum fast multipole method for linear scaling.

    Science.gov (United States)

    Korchowiec, Jacek; Lewandowski, Jakub; Makowski, Marcin; Gu, Feng Long; Aoki, Yuriko

    2009-11-30

    A linear-scaling implementation of the elongation cutoff technique (ELG/C) that speeds up Hartree-Fock (HF) self-consistent field calculations is presented. The cutoff method avoids the known bottleneck of the conventional HF scheme, that is, diagonalization, because it operates within the low dimension subspace of the whole atomic orbital space. The efficiency of ELG/C is illustrated for two model systems. The obtained results indicate that the ELG/C is a very efficient sparse matrix algebra scheme. Copyright 2009 Wiley Periodicals, Inc.

  9. Can semiquantitative measurements of SUVmax and cut-off values differentiate colorectal malignant from benign lessions?

    DEFF Research Database (Denmark)

    Nguyen, Tram; Hess, Søren; Petersen, Henrik

    2017-01-01

    , which also precludes a clinically significant cut-off value. The same applies to SUVpeak and SUVmean while TLG measures may be more indicative. CONCLUSION: Semi-quantitative measurements of SUVmax and cut-off values proved inadequate for differentiating colorectal malignancies from benign findings...

  10. Determination of cutoff of ELISA and immunofluorescence assay for scrub typhus

    Directory of Open Access Journals (Sweden)

    Nitin Gupta

    2016-01-01

    Full Text Available Background: The most common method employed for diagnosis of scrub typhus is serology. It is widely known that demonstration of ≥4-fold rise in titers of antibody in paired sera is required for diagnosis. However, for guidance of initial treatment, there is a need for rapid diagnosis at the time of admission. Therefore, there is a need for standardized region specific cutoff titers at the time of admission. Materials and Methods: A total of 258 patients of all age groups with clinically suspected scrub typhus over a period of 24 months (October 2013-October 2015 were enrolled. Serum samples of these patients were subjected to immunofluorescent antibody (IFA for immunoglobulin M (IgM (Fuller Labs, USA with dilutions of 1:64, 1:128, 1:256, and 1:512. Serum samples of all 258 patients were subjected to IgM ELISA (Inbios Inc., USA. Any patient with response to antibiotics within 48 h accompanied by either presence of an eschar or positivity by polymerase chain reaction was taken as positive. Receiver operating characteristic (ROC curve was drawn to generate cutoff for these tests. Results: A total of 20 patients were diagnosed as cases of scrub typhus. The ROC curve analysis revealed a cutoff optical density value of 0.87 with sensitivity and specificity of 100% and 94.12%, respectively. ROC curve analysis of IFA revealed sensitivity and specificity of 100% and 93.5%, respectively at 1:64 dilution. Conclusion: Considering cost constraints, centers in and around New Delhi region can use the cutoffs we determined for the diagnosis of scrub typhus.

  11. Equilibrium properties of blackbody radiation with an ultraviolet energy cut-off

    Science.gov (United States)

    Mishra, Dheeraj Kumar; Chandra, Nitin; Vaibhav, Vinay

    2017-10-01

    We study various equilibrium thermodynamic properties of blackbody radiation (i.e. a photon gas) with an ultraviolet energy cut-off. We find that the energy density, specific heat etc. follow usual acoustic phonon dynamics as have been well studied by Debye. Other thermodynamic quantities like pressure, entropy etc. have also been calculated. The usual Stefan-Boltzmann law gets modified. We observe that the values of the thermodynamic quantities with the energy cut-off is lower than the corresponding values in the theory without any such scale. The phase-space measure is also expected to get modified for an exotic spacetime appearing at Planck scale, which in turn leads to the modification of Planck energy density distribution and the Wien's displacement law. We found that the non-perturbative nature of the thermodynamic quantities in the SR limit (for both unmodified and modified cases), due to nonanalyticity of the leading term, is a general feature of the theory accompanied with an ultraviolet energy cut-off. We have also discussed the possible modification in the case of Big Bang and the Stellar objects and have suggested a table top experiment for verification in effective low energy case.

  12. Influence of Different Cut-Off Values on the Diagnosis of Mild Cognitive Impairment in Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Inga Liepelt-Scarfone

    2011-01-01

    Full Text Available Comparable to Alzheimer's disease, mild cognitive impairment in Parkinson's disease (PD-MCI is associated with an increased risk for dementia. However different definitions of PD-MCI may have varying predictive accuracy for dementia. In a cohort of 101 nondemented Parkinson patients who underwent neuropsychological testing, the frequency of PD-MCI subjects and PD-MCI subtypes (i.e., amnestic/nonamnestic was determined by use of varying healthy population-based cut-off values. We also investigated the association between defined PD-MCI groups and ADL scales. Varying cut-off values for the definition of PD-MCI were found to affect frequency of PD-MCI subjects (9.9%–92.1% and, maybe more important, lead to a “shift” of proportion of detected PD-MCI subtypes especially within the amnestic single-domain subtype. Models using a strict cut-off value were significantly associated with lower ADL scores. Thus, the use of defined cut-off values for the definition of PD-MCI is highly relevant for comparison purposes. Strict cut-off values may have a higher predictive value for dementia.

  13. Effects of increasing the PSA cutoff to perform additional biomarker tests before prostate biopsy.

    Science.gov (United States)

    Nordström, Tobias; Adolfsson, Jan; Grönberg, Henrik; Eklund, Martin

    2017-10-03

    Multi-step testing might enhance performance of the prostate cancer diagnostic pipeline. Using PSA >1 ng/ml for first-line risk stratification and the Stockholm 3 Model (S3M) blood-test >10% risk of Gleason Score > 7 prostate cancer to inform biopsy decisions has been suggested. We aimed to determine the effects of changing the PSA cutoff to perform reflex testing with S3M and the subsequent S3M cutoff to recommend prostate biopsy while maintaining the sensitivity to detect Gleason Score ≥ 7 prostate cancer. We used data from the prospective, population-based, paired, diagnostic Stockholm 3 (STHLM3) study with participants invited by date of birth from the Swedish Population Register during 2012-2014. All participants underwent testing with PSA and S3M (a combination of plasma protein biomarkers [PSA, free PSA, intact PSA, hK2, MSMB, MIC1], genetic polymorphisms, and clinical variables [age, family, history, previous prostate biopsy, prostate exam]). Of 47,688 men in the STHLM3 main study, we used data from 3133 men with S3M >10% and prostate biopsy data. Logistic regression models were used to calculate prostate cancer detection rates and proportion saved biopsies. 44.2%, 62.5% and 67.9% of the participants had PSA PSA cut-off for additional work-up from 1 ng/ml to 1.5 ng/ml would thus save 18.3% of the performed tests, 4.9% of the biopsies and 1.3% (10/765) of Gleason Grade ≥ 7 cancers would be un-detected. By lowering the S3M cutoff to recommend biopsy, sensitivity to high-grade prostate cancer can be restored, to the cost of increasing the number of performed biopsies modestly. The sensitivity to detect prostate cancer can be maintained when using different PSA cutoffs to perform additional testing. Biomarker cut-offs have implications on number of tests and prostate biopsies performed. A PSA cutoff of 1.5 ng/ml to perform additional testing such as the S3M test might be considered. ISRCTN84445406 .

  14. Deposition of a conductive near-infrared cutoff filter by radio-frequency magnetron sputtering

    International Nuclear Information System (INIS)

    Lee, Jang-Hoon; Lee, Seung-Hyu; Yoo, Kwang-Lim; Kim, Nam-Young; Hwangbo, Chang Kwon

    2002-01-01

    We have designed a conductive near-infrared (NIR) cutoff filter for display application, i.e., a modified low-emissivity filter based on the three periods of the basic design of [TiO2|Ti|Ag| TiO2] upon a glass substrate and investigated the optical, structural, chemical, and electrical properties of the conductive NIR cutoff filter prepared by a radio frequency magnetron sputtering system. The results show that the average transmittance is 61.1% in the visible, that the transmittance in the NIR is less than 6.6%, and that the sheet resistance and emissivity are 0.9 Ω/□ (where □ stands for a square film) and 0.012, respectively, suggesting that the conductive NIR cutoff filter can be employed as a shield against the hazard of electromagnetic waves as well as to cut off the NIR

  15. A proposed cutoff point of waist-to-height ratio for metabolic risk in African township adolescents

    OpenAIRE

    Kruger, H. Salomé; Faber, Mieke; Schutte, Aletta E.; Ellis, Suria M.

    2013-01-01

    Objective: A waist:height ratio (WHtR) higher than 0.5 has been proposed as a cutoff point for abdominal obesity in both sexes and at all ages. It is unknown if this cutoff point is appropriate for previously undernourished adolescents. We assessed the cutoff value of the WHtR associated with an increased metabolic risk in 178 black South African 14- to 18-y-old adolescents (69 boys, 109 girls). Methods: We measured weight, height, waist circumference, fasting plasma glucose an...

  16. Determination of a saliva cotinine cut-off to distinguish pregnant smokers from pregnant non-smokers

    DEFF Research Database (Denmark)

    Hegaard, Hanne K; Kjaergaard, Hanne; Møller, Lars F

    2007-01-01

    Objective validation of smoking status is necessary. Earlier studies have used saliva cotinine concentrations between 14.2 and 30 ng/ml as cut-off values to distinguish pregnant smokers from non-smokers. However, these cut-offs derive from studies including men and non-pregnant women. This consti...

  17. Effect of cutoff radius, long range interaction and temperature controller on thermodynamic properties of fluids: Methanol as an example

    Science.gov (United States)

    Obeidat, Abdalla; Jaradat, Adnan; Hamdan, Bushra; Abu-Ghazleh, Hind

    2018-04-01

    The best spherical cutoff radius, long range interaction and temperature controller were determined using surface tension, density, and diffusion coefficients of van Leeuwen and Smit methanol. A quite good range of cutoff radii from 0.75 to 1.45 nm has been studied on Coulomb cut-off and particle mesh Ewald (PME) long range interaction to determine the best cutoff radius and best long range interaction as well for four sets of temperature: 200, 230, 270 and 300 K. To determine the best temperature controller, the cutoff radius of 1.25 nm was fixed using PME long range interaction on calculating the above properties at low temperature range: 200-300 K.

  18. Hypertriglyceridemic waist phenotype in primary health care: comparison of two cutoff points

    Directory of Open Access Journals (Sweden)

    Braz MAD

    2017-09-01

    Full Text Available Marina Augusta Dias Braz,1 Jallyne Nunes Vieira,1 Flayane Oliveira Gomes,1 Priscilla Rafaella da Silva,1 Ohanna Thays de Medeiros Santos,1 Ilanna Marques Gomes da Rocha,2 Iasmin Matias de Sousa,2 Ana Paula Trussardi Fayh2 1Faculdade de Ciências da Saúde do Trairi, Universidade Federal do Rio Grande do Norte (UFRN, Santa Cruz, 2Department of Nutrition, Centro de Ciências da Saúde, UFRN, Natal, Rio Grande do Norte, Brazil Objective: We aimed to evaluate the prevalence of hypertriglyceridemic waist (HTGW phenotype among users of primary health care using two different cutoff points used in the literature. Methods: We evaluated adults and elderly individuals of both sexes who attended the same level of primary health care. HTGW phenotype was determined with measurements of waist circumference (WC and triglyceride levels and compared using cutoff points proposed by the National Cholesterol Education Program – NCEP/ATP III (WC ≥102 cm for men and ≥88 cm for women; triglyceride levels ≥150 mg/dL for both sexes and by Lemieux et al (WC ≥90 cm for men and ≥85 cm for women; triglyceride levels ≥177 mg/dL for both. Results: Within the sample of 437 individuals, 73.7% was female. The prevalence of HTGW phenotype was high and statistically different with the use of different cutoff points from the literature. The prevalence was higher using the NCEP/ATP III criteria compared to those proposed by Lemieux et al (36.2% and 32.5%, respectively, p<0.05. Individuals with the presence of the phenotype also presented alterations in other traditional cardiovascular risk markers. Conclusion: The HTGW phenotype identified high prevalence of cardiovascular risk in the population, with higher cutoff points from the NCEP/ATP III criteria. The difference in frequency of risk alerts us to the need to establish cutoff points for the Brazilian population. Keywords: abdominal obesity, cardiovascular disease, dyslipidemia, cardiovascular risk

  19. [Identification of cutoff points for Homeostatic Model Assessment for Insulin Resistance index in adolescents: systematic review].

    Science.gov (United States)

    Andrade, Maria Izabel Siqueira de; Oliveira, Juliana Souza; Leal, Vanessa Sá; Lima, Niedja Maria da Silva; Costa, Emília Chagas; Aquino, Nathalia Barbosa de; Lira, Pedro Israel Cabral de

    2016-06-01

    To identify cutoff points of the Homeostatic Model Assessment for Insulin Resistance (HOMA-IR) index established for adolescents and discuss their applicability for the diagnosis of insulin resistance in Brazilian adolescents. A systematic review was performed in the PubMed, Lilacs and SciELO databases, using the following descriptors: "Adolescents", "insulin resistance" and "ROC curve". Original articles carried out with adolescents published between 2005 and 2015 in Portuguese, English or Spanish languages, which included the statistical analysis using ROC curve to determine the index cutoff (HOMA-IR) were included. A total of 184 articles were identified and after the study phases were applied, seven articles were selected for the review. All selected studies established their cutoffs using a ROC curve, with the lowest observed cutoff of 1.65 for girls and 1.95 for boys and the highest of 3.82 for girls and 5.22 for boys. Of the studies analyzed, one proposed external validity, recommending the use of the HOMA-IR cutoff >2.5 for both genders. The HOMA-IR index constitutes a reliable method for the detection of insulin resistance in adolescents, as long as it uses cutoffs that are more adequate for the reality of the study population, allowing early diagnosis of insulin resistance and enabling multidisciplinary interventions aiming at health promotion of this population. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Epidemiological cut-off values for Flavobacterium psychrophilum MIC data generated by a standard test protocol.

    Science.gov (United States)

    Smith, P; Endris, R; Kronvall, G; Thomas, V; Verner-Jeffreys, D; Wilhelm, C; Dalsgaard, I

    2016-02-01

    Epidemiological cut-off values were developed for application to antibiotic susceptibility data for Flavobacterium psychrophilum generated by standard CLSI test protocols. The MIC values for ten antibiotic agents against Flavobacterium psychrophilum were determined in two laboratories. For five antibiotics, the data sets were of sufficient quality and quantity to allow the setting of valid epidemiological cut-off values. For these agents, the cut-off values, calculated by the application of the statistically based normalized resistance interpretation method, were ≤16 mg L(-1) for erythromycin, ≤2 mg L(-1) for florfenicol, ≤0.025 mg L(-1) for oxolinic acid (OXO), ≤0.125 mg L(-1) for oxytetracycline and ≤20 (1/19) mg L(-1) for trimethoprim/sulphamethoxazole. For ampicillin and amoxicillin, the majority of putative wild-type observations were 'off scale', and therefore, statistically valid cut-off values could not be calculated. For ormetoprim/sulphadimethoxine, the data were excessively diverse and a valid cut-off could not be determined. For flumequine, the putative wild-type data were extremely skewed, and for enrofloxacin, there was inadequate separation in the MIC values for putative wild-type and non-wild-type strains. It is argued that the adoption of OXO as a class representative for the quinolone group would be a valid method of determining susceptibilities to these agents. © 2014 John Wiley & Sons Ltd.

  1. Using Cut-off grade isograms to delineate ore body and calculate parameter

    International Nuclear Information System (INIS)

    Yu Yongfeng; Zhu Xiaobing; Deng Yonghui

    2014-01-01

    Taking a uranium mine for an example, using cut-off grade isograms to achieve automatic delineation of ore body and calculation of parameters are explored. With center line of catalog sampling as baseline, the number of sampling and length of sampling constructing rectangular grid and grade as elevation value, isograms of cut-off grade were drawn, thus achieving the delineation of the ore body. Then, the other parameters of the ore body can be calculated. Compared with the traditional hand drawing method, the work efficiency was greatly improved, and the material inquiry was more convenient. (authors)

  2. Partial ring currents and cosmic ray magnetic cutoff rigidity variations

    International Nuclear Information System (INIS)

    Arens, M.

    1978-01-01

    A short introduction on cosmic ray modulation and a description of the magnetosphere, and of some physical processes occurring within its boundaries are presented. 20 geomagnetic storms are analysed together with the cosmic ray intensities during these storms as measured by Neutron Monitors. Using a semi-empirical method, the variations in the magnetic cutoff rigidity for the mountain stations Pic du Midi and Jungfraujoch are deduced. These stations are the most sensitive for measuring these variations. The analysis shows that all analyzed storms have an asymmetric development phase. Often the asymmetry even continues during part of the recovery phase. It is shown that variations in magnetic cutoff rigidity occur only during the asymmetric phase of the storm. The largest variations are found when the cosmic ray station is located in the late afternoon-midnight sector. (Auth.)

  3. Quantification of progression and regression of descending thoracic aortic wall thickness by enhanced computed tomography

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi; Takasu, Junichiro; Yamamoto, Rie; Taguchi, Rie; Itani, Yasutaka; Ito, Yuichi; Watanabe, Shigeru; Masuda, Yoshiaki

    2001-01-01

    The purpose of this study is to verify the usefulness of the quantification of aortic wall involvement by enhanced computed tomography (CT). One-hundred thirteen Japanese patients underwent two enhanced CT of the descending thoracic aorta at intervals. We sliced the descending thoracic aorta continuously from the level of the tracheal bifurcation with 1 cm intervals, and we defined aortic wall volume (AWV) (cm 3 ) as the sum of a 7-slice area of aortic wall involving calcification. The average of AWV increased from 7.95±2.92 cm 3 to 8.70±2.98 cm 3 . The developmental rate of AWV (ΔAWV) was 0.270±0.281 cm 3 /year. ΔAWV did not have a significant correlation with any risk factor at the baseline. ΔAWV had significant correlation with total cholesterol, (LDL-C) low-density lipoprotein cholesterol and LDL-C/(HDL-C) high-density lipoprotein cholesterol ratio at the follow-up, and by multivariate analysis with only the LDL-C/HDL-C ratio. ΔAWV was not correlated with the intake status of hypoglycemic, antihypertensive or lipid-lowering drugs. The cut-off level of total cholesterol with the most significant odds ratio for progression of aortic wall was 190 mg/dl, and that of LDL-C was 130 mg/dl. This method proved to be useful for the non-invasive assessment of aortic wall thickness. (author)

  4. Plasma folic acid cutoff value, derived from its relationship with homocyst(e)ine.

    Science.gov (United States)

    Brouwer, D A; Welten, H T; Reijngoud, D J; van Doormaal, J J; Muskiet, F A

    1998-07-01

    We established the cutoff value for plasma folic acid, using plasma homocyst(e)ine as the functional marker. To do this, we investigated the relationship of the plasma folic acid of 103 apparently healthy adults with their fasting plasma homocyst(e)ine and with their plasma homocyst(e)ine 6 h after oral methionine challenge (100 mg/kg). We also studied the relationship of their plasma folic acid with the decline of fasting plasma homocyst(e)ine after 7 days of folic acid supplementation (5 mg/day). The three approaches suggested a cutoff value of 10 nmol/L. The chances of individuals to significantly (P ine after folic acid supplementation proved significantly higher at plasma folic acid concentrations < or = 10 nmol/L, as compared with folic acid concentrations above this value (odds ratio, 5.02; 95% confidence interval, 1.87-13.73). We suggest adopting a 10 nmo/L plasma folic acid cutoff value on functional grounds.

  5. Influence of the terrestrial magnetic field geometry on the cutoff rigidity of cosmic ray particles

    International Nuclear Information System (INIS)

    Herbst, K.; Kopp, A.; Heber, B.

    2013-01-01

    Studies of the propagation of charged energetic particles in the Earth's magnetic field go back to Carl Stoermer. In the end, his investigations finally lead to the definition of the so-called cutoff rigidity RC; that is, the minimum momentum per charge a particle must have in order to reach a certain geographical location. Employing Monte Carlo simulations with the PLANETOCOSMICS code we investigate the correlation between the geomagnetic field structure and the cutoff rigidity. We show that the geometry of the magnetic field has a considerable influence on the resulting cutoff rigidity distribution. Furthermore, we will present a simple geometry-based parameter, δB, which is able to reflect the location-dependent cutoff rigidity. We show that this correlation is also visible in the temporal evolution of the Earth's magnetic field, at least over the last 100 yr. Using latitude scans with neutron monitors, changes of the relative counting rates at different positions are calculated, showing small variations for, e.g., Kiel and Moscow, while large ones occur at Mexico City as well as on the British Virgin Islands.

  6. Efficiency and cutoff values of the Voice Activity and Participation Profile for nonteachers and teachers.

    Science.gov (United States)

    Zambon, Fabiana; Moreti, Felipe; Vargas, Aline Cristina Tafarelo; Behlau, Mara

    2015-01-01

    To identify the efficiency characteristics and cutoff values of the dimensions of the Voice Activity and Participation Profile (VAPP) protocol, which discriminates the dysphonic and vocally healthy individuals; to verify if the cutoff values remain the same for a sample of teachers. Efficiency characteristics and cutoff values of VAPP data from 171 subjects were analyzed by receiver-operating characteristic (ROC) curve: 90 teachers (60 dysphonic and 30 vocally healthy individuals, with a similar mean age, p=0.418) and 81 nonteachers (48 dysphonic and 33 vocally healthy individuals, with a similar mean age, p=0.934). The area under the ROC curve (AUC) and the cutoff values of the total score of VAPP for discriminating the individuals with and without dysphonia are different for the nonteachers and teachers. The nonteachers presented AUC=0.986 (pteachers presented AUC=0.872 (pteachers, being higher for the teachers but with greater sensitivity and specificity for the nonteachers, and can be used to screen large populations with the risk of voice disorders.

  7. Variation of multiplicity distributions for mean transverse momentum with cutoff in hardon-hardon collisions

    International Nuclear Information System (INIS)

    Lan Qikai; Liu Lianshou

    1995-01-01

    Using the three-fireball model, the multiplicity distributions for mean transverse momentum in hadron-hadron collisions at √s = 22 GeV is investigated. It is found that the change from negative to positive with increasing the transverse momentum cutoff comes from the following fact the rising scope of mean transverse momentum of hardon produced by side-fire balls with increasing the cutoff is greater than that of central fire balls

  8. The normative score and the cut-off value of the Oswestry Disability Index (ODI).

    Science.gov (United States)

    Tonosu, Juichi; Takeshita, Katsushi; Hara, Nobuhiro; Matsudaira, Ko; Kato, So; Masuda, Kazuhiro; Chikuda, Hirotaka

    2012-08-01

    The Oswestry Disability Index (ODI) is one of the most common scoring systems used for patients with low back pain (LBP). Although the normative score of the ODI was reported to be 10.19 in a review article, no study has calculated the normative score after adjusting the value based on the age distribution. In addition, none of the previous studies has estimated the cut-off value which separates LBP with disability from LBP without disability. The purpose of this study was to estimate the normative score by adjusting the data for age distribution in Japan, and to determine the cut-off value which separates LBP with disability from LBP without disability. We conducted an internet survey on LBP using the Japanese version of the ODQ. A total of 1,200 respondents, composed of 100 males and 100 females in each age group (from the 20s to 70s), participated in this study. We also asked them to provide information about their backgrounds. We estimated the normative score after correcting for the age distribution of Japan. We also estimated the ODI of those with or without disability, the factors associated with the ODI, and the cut-off value which separates LBP with disability from LBP without disability. The participants' backgrounds were similar to the national survey. The normative score of the ODI was estimated at 8.73. The ODI of the LBP with disability group was 22.07. Those with sciatica and obese subjects showed higher ODI than those without. The optimal cut-off value was estimated to be 12. We defined the normative score and the cut-off value of the ODI.

  9. The Cut-off Value of Blood Mercury Concentration in Relation to Insulin Resistance

    Directory of Open Access Journals (Sweden)

    Seok-Hoon Lee

    2017-09-01

    Full Text Available Background : Increased blood mercury concentration is associated with inflammation, and chronic inflammation can cause insulin resistance. We examined the cut-off value of blood mercury in relation to an increased score on the homeostasis model assessment for insulin resistance (HOMA-IR. Methods : We used data from the Korean National Health and Nutrition Examination Survey (2008–2010. Relevant data from 5,184 subjects (2,523 men and 2,661 women were analyzed cross-sectionally. General linear analysis was performed to evaluate the relationship between HOMA-IR score and blood mercury concentration. In addition, we determined the cut-off value of blood mercury concentration in relation to increased HOMA-IR score (> 2.34 using an ROC curve. Results : The mean value of blood mercury concentration in men and women was 5.88 μg/L and 4.11 μg/L, respectively. In men, comparing to the first quartile, HOMA-IR score increased significantly in the third and fourth blood mercury quartiles. In women, however, the increase in HOMA-IR score was not significant. The cut-off value that best represented the association between increased HOMA-IR score and blood mercury concentration in men was found to be 4.71 μg/L. Conclusion : Blood mercury concentration was associated with increased HOMA-IR score in men, and the cut-off value of blood mercury concentration that was correlated with increased HOMA-IR score was around 4.71 μg/L.

  10. Spectrally selective solar absorber with sharp and temperature dependent cut-off based on semiconductor nanowire arrays

    Science.gov (United States)

    Wang, Yang; Zhou, Lin; Zheng, Qinghui; Lu, Hong; Gan, Qiaoqiang; Yu, Zongfu; Zhu, Jia

    2017-05-01

    Spectrally selective absorbers (SSA) with high selectivity of absorption and sharp cut-off between high absorptivity and low emissivity are critical for efficient solar energy conversion. Here, we report the semiconductor nanowire enabled SSA with not only high absorption selectivity but also temperature dependent sharp absorption cut-off. By taking advantage of the temperature dependent bandgap of semiconductors, we systematically demonstrate that the absorption cut-off profile of the semiconductor-nanowire-based SSA can be flexibly tuned, which is quite different from most of the other SSA reported so far. As an example, silicon nanowire based selective absorbers are fabricated, with the measured absorption efficiency above (below) bandgap ˜97% (15%) combined with an extremely sharp absorption cut-off (transition region ˜200 nm), the sharpest SSA demonstrated so far. The demonstrated semiconductor-nanowire-based SSA can enable a high solar thermal efficiency of ≳86% under a wide range of operating conditions, which would be competitive candidates for the concentrated solar energy utilizations.

  11. TEMPERATURE GRADIENTS IN THE SOLAR ATMOSPHERE AND THE ORIGIN OF CUTOFF FREQUENCY FOR TORSIONAL TUBE WAVES

    International Nuclear Information System (INIS)

    Routh, S.; Musielak, Z. E.; Hammer, R.

    2010-01-01

    Fundamental modes supported by a thin magnetic flux tube embedded in the solar atmosphere are typically classified as longitudinal, transverse, and torsional waves. If the tube is isothermal, then the propagation of longitudinal and transverse tube waves is restricted to frequencies that are higher than the corresponding global cutoff frequency for each wave. However, no such global cutoff frequency exists for torsional tube waves, which means that a thin and isothermal flux tube supports torsional tube waves of any frequency. In this paper, we consider a thin and non-isothermal magnetic flux tube and demonstrate that temperature gradients inside this tube are responsible for the origin of a cutoff frequency for torsional tube waves. The cutoff frequency is used to determine conditions for the wave propagation in the solar atmosphere, and the obtained results are compared to the recent observational data that support the existence of torsional tube waves in the Sun.

  12. Anthropometric parameters’ cut-off points and predictive value for metabolic syndrome in women from Cartagena, Colombia

    Directory of Open Access Journals (Sweden)

    Gustavo José Mora-García

    2014-03-01

    Full Text Available Objective. To estimate anthropometric parameters’ (APs cut-off points and association for metabolic syndrome (MetS. Materials and methods. A cross-sectional study was carried out with a total of 434 adult women from Cartagena de Indias, Colombia, in 2012. APs measured were waist circumference (WC, body mass index (BMI, body adiposity index (BAI, waist-hip ratio (WHR and waist-height ratio (WHtR. Cut-off points were estimated by a receiver operating characteristic curve (ROC. Logistic regression was applied to estimate possible associations. Results. Cut-off points for WC, BMI, BAI, WHR and WHtR were 85 cm, 28 kg/m2, 39%, 0.80 and 56, respectively. Only WHtR was associated to MetS (OR=1.11, CI95% [1.07-1.15]. Conclusion. WC cut-off point was higher than those proposed for Latin-American women by the Joint Interim Statement (JIS. WHtR had a low predictive value for MetS.

  13. Measurement of current drive profile using electron cyclotron wave attenuation near the O-mode cutoff

    International Nuclear Information System (INIS)

    Fidone, I.; Meyer, R.L.; Caron, X.

    1992-01-01

    A method for determining the radial profile of the lower-hybrid current drive in tokamaks using electron cyclotron attenuation of the O mode for frequencies ω near the cutoff frequency is discussed. The basic idea is that, for a given wave frequency, the cutoff plays the role of a spatial filter selecting a variable portion of the noninductive current. It is shown that the incremental attenuation resulting from a small increase of ω displays specific features related to the current density near the cutoff point. Using the relation between the wave damping and the current density, it is possible to determine the radial profile of the current drive from the wave attenuation measurements. A numerical application is also presented for plasma parameters in the reactor regime

  14. Assessing cutoff values for increased exercise blood pressure to predict incident hypertension in a general population.

    Science.gov (United States)

    Lorbeer, Roberto; Ittermann, Till; Völzke, Henry; Gläser, Sven; Ewert, Ralf; Felix, Stephan B; Dörr, Marcus

    2015-07-01

    Cutoff values for increased exercise blood pressure (BP) are not established in hypertension guidelines. The aim of the study was to assess optimal cutoff values for increased exercise BP to predict incident hypertension. Data of 661 normotensive participants (386 women) aged 25-77 years from the Study of Health in Pomerania (SHIP-1) with a 5-year follow-up were used. Exercise BP was measured at a submaximal level of 100 W and at maximum level of a symptom-limited cycle ergometry test. Cutoff values for increased exercise BP were defined at the maximum sum of sensitivity and specificity for the prediction of incident hypertension. The area under the receiver-operating characteristic curve (AUC) and net reclassification index (NRI) were calculated to investigate whether increased exercise BP adds predictive value for incident hypertension beyond established cardiovascular risk factors. In men, values of 160  mmHg (100  W level; AUC = 0.7837; NRI = 0.534, P AUC = 0.7677; NRI = 0.340, P = 0.003) were detected as optimal cutoff values for the definition of increased exercise SBP. A value of 190  mmHg (AUC = 0.8347; NRI = 0.519, P < 0.001) showed relevance for the definition of increased exercise SBP in women at the maximum level. According to our analyses, 190 and 210  mmHg are clinically relevant cutoff values for increased exercise SBP at the maximum exercise level of cycle ergometry test for women and men, respectively. In addition, for men, our analyses provided a cutoff value of 160  mmHg for increased exercise SBP at the 100  W level.

  15. Young Athletes Cleared for Sports Participation After Anterior Cruciate Ligament Reconstruction: How Many Actually Meet Recommended Return-to-Sport Criterion Cutoffs?

    Science.gov (United States)

    Toole, Allison R; Ithurburn, Matthew P; Rauh, Mitchell J; Hewett, Timothy E; Paterno, Mark V; Schmitt, Laura C

    2017-11-01

    Study Design Prospective cohort study. Background While meeting objective criterion cutoffs is recommended prior to return to sports following anterior cruciate ligament (ACL) reconstruction, the number of young athletes who meet recommended cutoffs and the impact of cutoffs on longitudinal sports participation are unknown. Objectives To test the hypothesis that a higher proportion of young athletes who meet recommended cutoffs will maintain the same level of sports participation over the year following return-to-sport clearance compared to those who do not meet recommended cutoffs. Methods At the time of return-to-sport clearance, the International Knee Documentation Committee Subjective Knee Evaluation Form (IKDC), quadriceps and hamstring strength limb symmetry index (LSI), and single-leg hop test LSI were assessed. Proportions of participants who met individual (IKDC score of 90 or greater; strength and hop test LSIs of 90% or greater) and combined cutoffs were calculated. Proportions of participants who continued at the same level of sports participation over the year following return-to-sport clearance (assessed using the Tegner activity scale) were compared between those who met and did not meet cutoffs. Results Participants included 115 young athletes (88 female). The proportions meeting individual cutoffs ranged from 43.5% to 78.3%. The proportions meeting cutoffs for all hop tests, all strength tests, and all combined measures were 53.0%, 27.8%, and 13.9%, respectively. A higher proportion of participants who met cutoffs for both strength tests maintained the same level of sports participation over the year following return-to-sport clearance than those who did not (81.3% versus 60.2%, P = .02). Conclusion The proportions of young athletes after ACL reconstruction recently cleared for return to sports who met the combined criterion cutoffs were low. Those who met the criterion cutoffs for both strength tests maintained the same level of sports

  16. Research on cutoff wavelength of dominant mode and field patterns in trapezoidal microshield lines

    OpenAIRE

    SUN, Hai; WU, Yujiang

    2012-01-01

    The influence of the position of the metallic signal strip on the cutoff characteristic of the dominant mode and the field patterns in 3 types of trapezoidal microshield lines are calculated by the edge-based finite element method. These trapezoidal microshield lines include trapezoidal microshield lines with a single signal line, dual signal lines, and 3 signal lines. The cutoff wavelength of the dominant mode can be adjusted by changing the dimensions of metallic signal strips as w...

  17. Optimal Training for Time-Selective Wireless Fading Channels Using Cutoff Rate

    Directory of Open Access Journals (Sweden)

    Tong Lang

    2006-01-01

    Full Text Available We consider the optimal allocation of resources—power and bandwidth—between training and data transmissions for single-user time-selective Rayleigh flat-fading channels under the cutoff rate criterion. The transmitter exploits statistical channel state information (CSI in the form of the channel Doppler spectrum to embed pilot symbols into the transmission stream. At the receiver, instantaneous, though imperfect, CSI is acquired through minimum mean-square estimation of the channel based on some set of pilot observations. We compute the ergodic cutoff rate for this scenario. Assuming estimator-based interleaving and -PSK inputs, we study two special cases in-depth. First, we derive the optimal resource allocation for the Gauss-Markov correlation model. Next, we validate and refine these insights by studying resource allocation for the Jakes model.

  18. A geometric classification of traveling front propagation in the Nagumo equation with cut-off

    International Nuclear Information System (INIS)

    Popovic, N

    2011-01-01

    An important category of solutions to reaction-diffusion systems of partial differential equations is given by traveling fronts, which provide a monotonic connection between rest states and maintain a fixed profile when considered in a co-moving frame. Reaction-diffusion equations are frequently employed in the mean-field (continuum) approximation of discrete (many-particle) models; however, the quality of this approximation deteriorates when the number of particles is not sufficiently large. The (stochastic) effects of this discreteness have been modeled via the introduction of (deterministic) 'cut-offs' that effectively deactivate the reaction terms at points where the particle concentration is below a certain threshold. In this article, we present an overview of the effects of such a cut-off on the front propagation dynamics in a prototypical reaction-diffusion system, the classical Nagumo equation. Our analysis is based on the method of geometric desingularization ('blow-up'), in combination with dynamical systems techniques such as invariant manifolds and normal forms. Using these techniques, we categorize front propagation in the cut-off Nagumo equation in dependence of a control parameter, and we classify the corresponding propagation regimes ('pulled,' 'pushed,' and 'bistable') in terms of the bifurcation structure of a projectivized system of equations that is obtained from the original traveling front problem, after blow-up. In particular, our approach allows us to determine rigorously the asymptotics (in the cut-off parameter) of the correction to the front propagation speed in the Nagumo equation that is due to a cut-off. Moreover, it explains the structure of that asymptotics (logarithmic, superlinear, or sublinear) in dependence of the front propagation regime. Finally, it enables us to calculate the corresponding leading-order coefficients in the resulting expansions in closed form.

  19. Prevalence and risk factors with overweight and obesity among Vietnamese adults: Caucasian and Asian cut-offs.

    Science.gov (United States)

    Trinh, Oanh T H; Nguyen, Nguyen D; Phongsavan, Philayrath; Dibley, Michael J; Bauman, Adrian E

    2009-01-01

    To determine the prevalence and factors associated with overweight/obesity among adults in Ho Chi Minh City (HCMC) using Caucasian and Asian cut-offs. A cross-sectional survey. In 2005, 1,971 adults aged 25-64 years in HCMC were randomly selected using a proportional to population size sampling method to estimate the prevalence of overweight and obesity, measured by body mass index (BMI) and waist circumference. Multivariable logistic models were used to examine associations between overweight/obesity and socioeconomic status, health-related behaviors, and biochemical indices of chronic disease risk. The prevalence of overweight and obesity using the Caucasian BMI cut-offs were 13.9% and 1.8% respectively, and those with the Asian BMI cut-offs were 27.5% and 5.7%, respectively. The abdominal adiposity rates were higher than the BMI overweight and obesity rates in women, but not in men. Increasing age, low education, high household wealth index, high levels of sitting and reclining time, cholesterol and high blood pressure were significantly associated with overweight and obesity. Current smoking and sedentary leisure time was significantly negatively associated with this status in men. Associations between overweight/obesity and metabolic disorders were evident using both cut-offs. Asian cut-offs identified more risk factors and therefore could be considered for defining at-risk groups. The results highlight the importance of intervention programs to prevent overweight/obesity in young adults.

  20. Open Skies and monitoring a fissile materials cut-off treaty

    International Nuclear Information System (INIS)

    Allentuck, J.; Lemley, J.R.

    1995-01-01

    The Treaty on Open Skies (Open Skies) is intended among other things to provide, in the words of its preamble, means ''to facilitate the monitoring of compliance with existing or future arms control agreements.'' Open Skies permits overflights of the territory of member states by aircraft equipped with an array of sensors of various types. Their types and capabilities are treaty-limited. To find useful application in monitoring a cut-off treaty Open Skies would need to be amended. The number of signatories would need to be expanded so as to provide greater geographical coverage, and restrictions on sensor-array capabilities would need to be relaxed. To facilitate the detection of impending violations of a cut-off convention by Open Skies overflights, the data base provided by parties to the former should include among other things an enumeration of existing and former fuel cycle and research facilities including those converted to other uses, their precise geographic location, and a site plan

  1. Holographic bounds on the UV cutoff scale in inflationary cosmology

    DEFF Research Database (Denmark)

    Keski-Vakkuri, Esko; Sloth, Martin Snoager

    2003-01-01

    We discuss how holographic bounds can be applied to the quantum fluctuations of the inflaton. In general the holographic principle will lead to a bound on the UV cutoff scale of the effective theory of inflation, but it will depend on the coarse-graining prescription involved in calculating...

  2. Normal Limits of Electrocardiogram and Cut-Off Values for Left ...

    African Journals Online (AJOL)

    olayemitoyin

    The cut-off values for Sokolow-Lyon, Cornell and Araoye criteria for assessment of left ventricular hypertrophy. (LVH) were higher than those previously in ... MATERIALS AND METHODS. This was a cross-sectional descriptive ..... criteria, Araoye code system and Ogunlade criterion were derived from the addition of two or ...

  3. Modeling Optimal Cutoffs for the Brazilian Household Food Insecurity Measurement Scale in a Nationwide Representative Sample.

    Science.gov (United States)

    Interlenghi, Gabriela S; Reichenheim, Michael E; Segall-Corrêa, Ana M; Pérez-Escamilla, Rafael; Moraes, Claudia L; Salles-Costa, Rosana

    2017-07-01

    Background: This is the second part of a model-based approach to examine the suitability of the current cutoffs applied to the raw score of the Brazilian Household Food Insecurity Measurement Scale [Escala Brasileira de Insegurança Alimentar (EBIA)]. The approach allows identification of homogeneous groups who correspond to severity levels of food insecurity (FI) and, by extension, discriminant cutoffs able to accurately distinguish these groups. Objective: This study aims to examine whether the model-based approach for identifying optimal cutoffs first implemented in a local sample is replicated in a countrywide representative sample. Methods: Data were derived from the Brazilian National Household Sample Survey of 2013 ( n = 116,543 households). Latent class factor analysis (LCFA) models from 2 to 5 classes were applied to the scale's items to identify the number of underlying FI latent classes. Next, identification of optimal cutoffs on the overall raw score was ascertained from these identified classes. Analyses were conducted in the aggregate data and by macroregions. Finally, model-based classifications (latent classes and groupings identified thereafter) were contrasted to the traditionally used classification. Results: LCFA identified 4 homogeneous groups with a very high degree of class separation (entropy = 0.934-0.975). The following cutoffs were identified in the aggregate data: between 1 and 2 (1/2), 5 and 6 (5/6), and 10 and 11 (10/11) in households with children and/or adolescents category emerged consistently in all analyses. Conclusions: Nationwide findings corroborate previous local evidence that households with an overall score of 1 are more akin to those scoring negative on all items. These results may contribute to guide experts' and policymakers' decisions on the most appropriate EBIA cutoffs. © 2017 American Society for Nutrition.

  4. Tunneling-induced shift of the cutoff law for high-order above-threshold ionization

    International Nuclear Information System (INIS)

    Lai, X. Y.; Quan, W.; Liu, X.

    2011-01-01

    We investigate the cutoff law for high-order above-threshold ionization (HATI) within a semiclassical framework. By explicitly adopting the tunneling effect and considering the initial position shift of the tunneled electron from the origin in the model, the cutoff energy position in HATI spectrum exhibits a well-defined upshift from the simple-man model prediction. The comparison between numerical results from our improved semiclassical model and the quantum-orbit theory shows a good agreement for small values of the Keldysh parameter γ, implying the important role of the inherent quantum tunneling effect in HATI dynamics.

  5. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    Science.gov (United States)

    Vawter, G.A.; Smith, R.E.

    1998-04-28

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides. 7 figs.

  6. Identification of sarcopenic obesity in postmenopausal women: a cutoff proposal

    Directory of Open Access Journals (Sweden)

    R.J. Oliveira

    2011-11-01

    Full Text Available Sarcopenic obesity is the combination of reduced fat-free mass (FFM and increased fat mass (FM with advancing age but there is lack of clear criteria for its identification. The purposes of the present investigation were: 1 to determine the prevalence of postmenopausal women with reduced FFM relative to their FM and height, and 2 to examine whether there are associations between the proposed classification and health-related variables. A total of 607 women were included in this cross-sectional study and were separated into two subsets: 258 older women with a mean age of 66.8 ± 5.6 years and 349 young women aged 18-40 years (mean age, 29.0 ± 7.5 years. All volunteers underwent body composition assessment by dual-energy X-ray absorptiometry. The FFM index relative to FM and height was calculated and the cutoff value corresponded to two standard deviations below the mean of the young reference group. To examine the clinical significance of the classification, all older participants underwent measurements of quadriceps strength and cardiorespiratory fitness. Values were compared between those who were classified as low FFM or not, using an independent samples t-test and correlations were examined. The cutoff corresponded to a residual of -3.4 and generated a sarcopenic obesity prevalence of 19.8% that was associated with reduced muscle strength and aerobic fitness among the older participants. Also, the index correlated significantly with the health-related fitness variables. The results demonstrated reduced functional capacity for those below the proposed cutoff and suggested applicability of the approach as a definition for sarcopenic obesity.

  7. A general equation to obtain multiple cut-off scores on a test from multinomial logistic regression.

    Science.gov (United States)

    Bersabé, Rosa; Rivas, Teresa

    2010-05-01

    The authors derive a general equation to compute multiple cut-offs on a total test score in order to classify individuals into more than two ordinal categories. The equation is derived from the multinomial logistic regression (MLR) model, which is an extension of the binary logistic regression (BLR) model to accommodate polytomous outcome variables. From this analytical procedure, cut-off scores are established at the test score (the predictor variable) at which an individual is as likely to be in category j as in category j+1 of an ordinal outcome variable. The application of the complete procedure is illustrated by an example with data from an actual study on eating disorders. In this example, two cut-off scores on the Eating Attitudes Test (EAT-26) scores are obtained in order to classify individuals into three ordinal categories: asymptomatic, symptomatic and eating disorder. Diagnoses were made from the responses to a self-report (Q-EDD) that operationalises DSM-IV criteria for eating disorders. Alternatives to the MLR model to set multiple cut-off scores are discussed.

  8. Wilsonian Renormalization Group and the Lippmann-Schwinger Equation with a Multitude of Cutoff Parameters

    Science.gov (United States)

    Epelbaum, E.; Gegelia, J.; Meißner, Ulf-G.

    2018-03-01

    The Wilsonian renormalization group approach to the Lippmann-Schwinger equation with a multitude of cutoff parameters is introduced. A system of integro-differential equations for the cutoff-dependent potential is obtained. As an illustration, a perturbative solution of these equations with two cutoff parameters for a simple case of an S-wave low-energy potential in the form of a Taylor series in momenta is obtained. The relevance of the obtained results for the effective field theory approach to nucleon-nucleon scattering is discussed. Supported in part by BMBF under Grant No. 05P2015 - NUSTAR R&D), DFG and NSFC through Funds Provided to the Sino- German CRC 110 “Symmetries and the Emergence of Structure in QCD”, National Natural Science Foundation of China under Grant No. 11621131001, DFG Grant No. TRR110, the Georgian Shota Rustaveli National Science Foundation (grant FR/417/6-100/14) and the CAS President’s International Fellowship Initiative (PIFI) under Grant No. 2017VMA0025

  9. The Cut-off Values of Triglycerides and Glucose Index for Metabolic Syndrome in American and Korean Adolescents.

    Science.gov (United States)

    Moon, Shinje; Park, Joon Sung; Ahn, Youhern

    2017-03-01

    The aim of this study was to establish ethnic- and gender-specific cut-off values of triglycerides and glucose index (TyG index) for clinical usefulness in a representative sample of Mexican American, Non-Hispanic White, Non-Hispanic Black, and Korean adolescents. The data were collected from datasets of the National Health and Nutrition Examination Survey between 1999 and 2012, and the Korean National Health and Nutrition Examination Survey between 2005 and 2013. Receiver operating characteristic curve analysis was used to find valid cut-off values of the TyG index for metabolic syndrome. The total number of eligible participants was 3,164 in the US and 4,873 in Korea. The optimal cut-off value with the Cook et al. definition revealed 8.55 in Mexican American, 8.55 in Non-Hispanic White, 8.35 in Non-Hispanic Black, and 8.45 in Korean, respectively. The cut-off value with the de Ferranti et al. definition was 8.45, 8.45, 8.15, and 8.35, and the cut-off value with the International Diabetes Federation definition was 8.65, 8.65, 8.15, and 8.55, respectively. These findings may be clinically useful for evaluating insulin resistance for determining metabolic abnormalities in adolescents.

  10. Limit load analysis of thick-walled concrete structures

    International Nuclear Information System (INIS)

    Argyris, J.H.; Faust, G.; Willam, K.J.

    1975-01-01

    The paper illustrates the interaction of constitutive modeling and finite element solution techniques for limit load prediction of concrete structures. On the constitutive side, an engineering model of concrete fracture is developed in which the Mohr-Coulomb criterion is augmented by tension cut-off to describe incipient failure. Upon intersection with the stress path the failure surface collapses for brittle behaviour according to one of three softening rules, no-tension, no-cohesion, and no-friction. The stress transfer accompanying the energy dissipation during local failure is modelled by several fracture rules which are examined with regard to ultimate load prediction. On the numerical side the effect of finite element idealization is studied first as far as ultimate load convergence is concerned. Subsequently, incremental tangential and initial load techniques are compared together with the effect of step size. Limit load analyses of a thick-walled concrete ring and a lined concrete reactor closure conclude the paper with examples from practical engineering. (orig.) [de

  11. Defining a BMI Cut-Off Point for the Iranian Population: The Shiraz Heart Study.

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Babai

    Full Text Available In this study we evaluated and redefined the optimum body mass index (BMI cut-off point for the Iranian population based on metabolic syndrome (MeS risk factors. We further evaluated BMI cut-off points with and without waist circumference (WC as a cofactor of risk and compared the differences. This study is part of the largest surveillance programs conducted in Shiraz, Iran, termed the Shiraz Heart study. Our study sample included subjects between the ages of 20 to 65 years old. After excluding pregnant women, those with missing data and those with comorbid disease, a total of 12283 made up the study population. The participants underwent a series of tests and evaluations by trained professionals in accordance with WHO recommendations. Hypertension, abnormal fasting blood sugar (FBS, triglyceride (TG and high density lipoprotein cholesterol (HDL (in the context of the definition of metabolic syndrome were prevalent among 32.4%, 27.6%, 42.1 and 44.2% of our participants, respectively. Women displayed higher rates of overall obesity compared to men (based on the definition by the WHO as higher than 30 kg/m2. Regarding MeS, 38.9% of our population had the all symptoms of MeS which was more prevalent among women (41.5% vs. 36%. When excluding WC in the definition of MeS, results showed that males tend to show a higher rate of metabolic risk factors (19.2% vs. 15.6%. Results of multivariate analysis showed that parallel to an increase in BMI, the odds ratio (OR for acquiring each component of the metabolic syndrome increased (OR = 1.178; CI: 1.166-1.190. By excluding WC, the previous OR decreased (OR = 1.105; CI: 1.093-1.118. Receiver Operating Characteristic (ROC curve analysis showed that the optimum BMI cut-off point for predicting metabolic syndrome was 26.1 kg/m2 and 26.2 kg/m2 [Accuracy (Acc = 69% and 61%, respectively] for males and females, respectively. The overall BMI cut-off for both sexes was 26.2 kg/m2 (Acc = 65% with sensitivity and

  12. Selecting a Cutoff Point for a Developmental Screening Test Based on Overall Diagnostic Indices and Total Expected Utilities of Professional Preferences

    Directory of Open Access Journals (Sweden)

    Hua-Fang Liao

    2010-03-01

    Conclusion: If only one cutoff point can be chosen, the authors suggest that clinicians should choose cutoff point B when using the Taipei II for screening. However, two cutoff points of Taipei II, a combination of strategy A and B, can also be used clinically.

  13. Screening for Internet Addiction: An Empirical Study on Cut-off Points for the Chen Internet Addiction Scale

    Directory of Open Access Journals (Sweden)

    Chih-Hung Ko

    2005-12-01

    Full Text Available The aim of this study was to establish the optimal cut-off points of the Chen Internet Addiction Scale (CIAS, to screen for and diagnose Internet addiction among adolescents in the community by using the well- established diagnostic criteria of Internet addiction. This survey of 454 adolescents used screening (57/58 and diagnostic (63/64 cut-off points of the CIAS, a self-reported instrument, based on the results of systematic diagnostic interviews by psychiatrists. The area under the curve of the receiver operating characteristic curve revealed that CIAS has good diagnostic accuracy (89.6%. The screening cut-off point had high sensitivity (85.6% and the diagnostic cut-off point had the highest diagnostic accuracy, classifying 87.6% of participants correctly. Accordingly, the screening point of the CIAS could provide a screening function in two-stage diagnosis, and the diagnostic point could serve as a diagnostic criterion in one-stage massive epidemiologic research.

  14. The evaluation of cutoff rigidities and reentrant albedo calculations for Palestine, Dallas, and Midland, Texas

    International Nuclear Information System (INIS)

    Shea, M.A.; Smart, D.F.

    1975-01-01

    By using the trajectory-tracing technique, cutoff rigidities for Palestine, Dallas, and Midland, Texas, have been calculated as a function of various zenith and azimuth angles. Extensive analysis of the trajectory calculations shows that there is a systematic uncertainty involved in computing the lowest allowed rigidity, and this uncertainty may be a significant fraction of the penumbral width. Continuation of the trajectory-tracing process below the Stormer cutoff allows an evaluation of the reentrant albedo, showing that the average invariant latitude of the guiding center of the trajectory at the albedo origin is the same as the average invariant latitude of the guiding center of the particle trajectory at the detection point. No significant difference in the cutoff rigidities for these locations is found when the external magnetic fields present in the magnetosphere are added to the geomagnetic field of internal origin

  15. Current MUAC Cut-Offs to Screen for Acute Malnutrition Need to Be Adapted to Gender and Age: The Example of Cambodia

    Science.gov (United States)

    Fiorentino, Marion; Sophonneary, Prak; Laillou, Arnaud; Whitney, Sophie; de Groot, Richard; Perignon, Marlène; Kuong, Khov; Berger, Jacques; Wieringa, Frank T.

    2016-01-01

    Background Early identification of children malnutrition is a priority. Acute malnutrition is defined by the World Health Organization as a mid-upper-arm circumference (MUAC) malnutrition in communities, but MUAC cut-offs currently recommended by WHO do not identify the majority of children with weight-for-height Z-score (5 yrs. Therefore, this study aimed at defining gender and age-specific cut-offs to improve sensitivity of MUAC as an indicator of acute malnutrition. Methods To establish new age and gender-specific MUAC cut-offs, pooled data was obtained for 14,173 children from 5 surveys in Cambodia (2011–2013). Sensitivity, false positive rates, and areas under receiver-operator characteristic curves (AUC) were calculated using wasting for children 80% with the new cut-offs in comparison with the current WHO cut-offs. Conclusion Gender and age specific MUAC cut-offs drastically increased sensitivity to identify children with WHZ-score malnutrition at the community level. PMID:26840899

  16. Accuracy of Body Mass Index Cutoffs for Classifying Obesity in Chilean Children and Adolescents

    Directory of Open Access Journals (Sweden)

    Rossana Gómez-Campos

    2016-05-01

    Full Text Available Objective: To determine the accuracy of two international Body Mass Index (BMI cut-offs for classifying obesity compared to the percentage of fat mass (%FM assessed by Dual-Energy X-ray Absorptiometry (DXA in a Chilean sample of children and adolescents; Material and Methods: The subjects studied included 280 children and adolescents (125 girls and 155 boys aged 8 to 17 years. Weight and height were measured. The BMI was calculated. Two international references (IOFT and WHO were used as cut-off points. The %FM was assessed by DXA. The receiver operating characteristic (ROC curve was used to assess the performance of BMI in detecting obesity on the basis of %FM; Results: A high correlation was observed between the %FM measured by the DXA and the Z-scores of IOTF and WHO scores in the Chilean adolescents separated by sex (r = 0.78–0.80. Differences occurred in both references (IOFT and WHO in relation to the criteria (p < 0.001. Both references demonstrated a good ability to predict sensitivity (between 84% and 93% and specificity (between 83% and 88% in both sexes of children and adolescents; Conclusions: A high correlation was observed between the Z-score of the BMI with the percentage of fat determined by the DXA. Despite this, the classifications using the different BMI cut-off points showed discrepancies. This suggests that the cut-off points selected to predict obesity in this sample should be viewed with caution.

  17. Accuracy of unfolded map method for determining the left ventricular border. Evaluation of the cut-off value from autopsy finding

    International Nuclear Information System (INIS)

    Sugibayashi, Keiichi; Abe, Yoshiteru; Suga, Yutaka

    1996-01-01

    To improve the quantification of the left ventricular surface area (LVSA) by unfolded map method, we evaluated the cut-off value for determining the left ventricular border. The LVSA measured by unfolded map was compared with those measured using myocardial phantom and autopsy findings. The relative error (RE) was calculated as difference between LVSA in phantom and area of unfolded map. In phantom study, the cut-off value was calculated as 73.3±0.5% when the RE was zero. In autopsy study, the cut-off value was 74.0±7.2%. The area of unfolded map had good correlation with LVSA at autopsy when the cut-off value was 74% (r=0.83, p<0.003). The diameter of left ventricle at autopsy was compared with that of beating heart obtained by two-dimensional echocardiography, because the area of unfolded map was greater than LVSA at autopsy. The ratio of LVSA at autopsy to beating heart was calculated as 1.37. The suitable cut-off value was evaluated as 55.6% when the unfolded map area obtained by autopsy was increased 1.37 magnifications. There was a good correlation between LVSA of unfolded map (cut-off=56%) and the LVSA at autopsy (r=0.90, p<0.001). These results suggest that the cut-off value for determining the left ventricular border in vivo is 56%. (author)

  18. [The optimal cutoff value of waist-to-height ratio in Chinese: based on cardiovascular risk and metabolic disease].

    Science.gov (United States)

    Jia, A H; Xu, S Y; Ming, J; Zhou, J; Zhang, W C; Hao, P R; Ji, Q H

    2017-11-01

    Objective: Waist-to-height ratio (WHtR), a measurement of the distribution of body fat, correlated with abdominal obesity indicating that it might be a better predictor of cardiovascular risk and metabolic disease. We, therefore, evaluated optimal WHtR cutoff points according to the risk of framingham risk score (FRS) and metabolic syndrome (MS) in Chinese. Methods: The subjects were from China National Diabetes and Metabolic Disorders Survey during 2007-2008. Receiver operating characteristic analysis was used to examine the optimal cutoff values of WHtR according to the risk of FRS and MS. Results: A total of 27 820 women and 18 419 men were included in the evaluation. The average age was (45.0±13.7) years. The proportions of FRS ≥10% and MS increased with WHtR both in men and women. The cutoff points of WHtR for the risk of FRS ≥10% and MS were 0.51, 0.52 in men, and 0.52, 0.53 in women, respectively. When FRS ≥10% and MS were taken into consideration with a certain weights, the pooled cutoffs of WHtR were 0.51 in men, and 0.53 in women, respectively. By using the similar method, the optimized cutoff points were 0.52, 0.51, 0.50 for men and 0.51, 0.53, 0.54 for women in age group 20-39, 40-59 and ≥60 years, respectively. Conclusions: The optimal cutoffs of WHtR are 0.51 in men, and 0.53 in women for FRS≥10% in combination with MS indicating that this WHtR cutoff points might be used as indexes to evaluate obesity and risk of obesity-related diseases.

  19. Age-adjusted D-dimer cut-off in the diagnostic strategy for deep vein thrombosis

    DEFF Research Database (Denmark)

    Nybo, Mads; Hvas, Anne-Mette

    2017-01-01

    BACKGROUND: Studies have indicated that use of an age-adjusted D-dimer cut-off value for patients above 50 years increases utility of the diagnostic strategy for pulmonary embolism. Evidence for the same approach regarding diagnosis of deep vein thrombosis (DVT) is, however, unclear. MATERIALS...... AND METHODS: A systematic literature review was conducted following the PRISMA Statement guideline to gather the existing knowledge on the use of an age-adjusted D-dimer cut-off in the diagnostic strategy for DVT. Studies were extracted from Medline and the Cochrane Library. The search period ended...

  20. Aid cutoff threatens condom program in Pakistan.

    Science.gov (United States)

    Barron, T

    1991-01-01

    The Pressler Amendment, a law prohibiting US assistance to any country that does not sign the UN Nuclear Nonproliferation Treaty, is forcing USAID to shut down its highly successful Social Marketing of Contraceptives (SMC) program in Pakistan. Adopted in 1985, the amendment calls for an end of funding for projects in Pakistan as of fiscal year 1991, since the country has refused to sign the treaty. Only previously committed funds have kept SMC running, but it may soon have a close shop. The cutoff comes at an especially inopportune time--just when SMC had begun to make an impact. Introduced 5 years ago, Sathi condoms (the project's main product) account for 2/3 of all condoms used in Pakistan. Sales jumped from 30 million in 1978 to 74 million last year. SMC administrators explain that the country has a vast potential for social marketing. But because of the cutoff in aid, the program will exhaust its supply of condoms by March 1992. The end of the SMC program will mean a serious setback for Pakistan, which already has the 2nd largest population in southern Asia, and which has double the fertility of the most populous country in the region, India. Only 7% of the women in Pakistan rely on a modern method of contraception, compared to 42% in India and 26% in Bangladesh. USAID officials explain that the organization is working with the Pakistani government to find ways to continue funding the program after US funds run out. They add that this development will provide Pakistani Prime Minister Nawaz Sharif an opportunity to demonstrate his stated commitment to curb population growth.

  1. Polypharmacy Cutoff for Gait and Cognitive Impairments

    Directory of Open Access Journals (Sweden)

    Antoine Langeard

    2016-08-01

    Full Text Available BACKGROUND: Polypharmacy is a well-established risk factor for falls, and these are one of the major health problems that affect the quality of life as people age. However, the risk of mobility and cognitive impairments consecutive to polypharmacy has been little addressed, despite the association between these adverse outcomes and falls. Moreover, the rare polypharmacy cut-offs were all but one arbitrarily determined. OBJECTIVE: Studying relationships between polypharmacy and both mobility and cognitive impairments, and statistically determining a cut-off point in the number of drugs beyond which polypharmacy has deleterious consequences with respect to mobility and cognitive impairment. METHODS: We enrolled 113 community-dwelling adults aged 55 years and older with a fall history, with or without injury, in the previous year. We carefully collected information about daily medications taken. We assessed basic mobility and global cognition with the Time-Up-and-Go and the Montreal Cognitive Assessment (MoCA test, respectively. (clinicaltrials.gov NCT02292316RESULTS: TUG and MoCA scores were both significantly correlated with the number of medications used. ROC curves indicate, with high prediction (p<0.002, that daily consumption of five or more medications is associated with risk for both impaired mobility and global cognition. These relationships were independent of the number of comorbidities and of the pharmacological class. CONCLUSION: Community-dwelling adults aged 55 years and older who take five or more daily drugs are at high risk for both mobility and cognitive impairments. Physicians and patients should be aware of these new findings, especially when there are multiple prescribers involved in the care of the patient.

  2. Waist circumference cut-off points for identification of abdominal obesity among the tunisian adult population.

    Science.gov (United States)

    Bouguerra, R; Alberti, H; Smida, H; Salem, L B; Rayana, C B; El Atti, J; Achour, A; Gaigi, S; Slama, C B; Zouari, B; Alberti, K G M M

    2007-11-01

    Waist circumference (WC) is a convenient measure of abdominal adipose tissue. It itself is a cardiovascular disease (CVD) and diabetes-risk factor and is strongly linked to other CVD risk factors. There are, however, ethnic differences in the relationship of WC to the other risk factors. The aim of this study was to determine the optimal cut-off points of WC and body mass index (BMI) at which cardiovascular risk factors can be identified with maximum sensitivity and specificity in a representative sample of the Tunisian adult population and to investigate any correlation between WC and BMI. We used a sample of the Tunisian National Nutrition Survey, a cross-sectional population-based survey, conducted in 1996 on a large nationally representative sample, which included 3435 adults (1244 men and 2191 women) of 20 years or older. WC, BMI, blood pressure and fasting blood measurements (plasma glucose, total cholesterol, triglycerides) were recorded. Receiver operating characteristic (ROC) curve analysis was used to identify optimal cut-off values of WC and BMI to identify with maximum sensitivity and specificity the detection of high blood pressure, hyperglycaemia, high blood cholesterol and hypertriglyceridaemia. ROC curve analysis suggested WC cut-off points of 85 cm in men and 85 cm in women for the optimum detection of high blood pressure, diabetes and dyslipidaemia. The optimum BMI cut-off points for predicting cardiovascular risk factors were 24 kg/m(2) in men and 27 kg/m(2) in women. The cut-off points recommended for the Caucasian population differ from those appropriate for the Tunisian population. The data show a continuous increase in odds ratios of each cardiovascular risk factor, with increasing level of WC and BMI. WC exceeding 85 cm in men and 79 cm in women correctly identified subjects with a BMI of >/=25 kg/m(2), sensitivity of >90% and specificity of >83%. Based on the ROC analysis, we suggest a WC of 85 cm for both men and women as appropriate cut-off

  3. Proceedings from the Fissile Material Cut-off seminar in Stockholm

    International Nuclear Information System (INIS)

    Arbman, G.

    1998-01-01

    The Swedish Defence Research Establishment hosted an international expert seminar on the subject of verifying a prohibition of the production of fissile material for nuclear weapons purpose (cut-off) in Stockholm, June 3-5 1998. The objective of the seminar was to provide an opportunity for informal discussions among scientific and technical experts on various technical matters relating to the verification of a future Fissile Material Cut-off Treaty (FMCT). A stated aim of the seminar was to keep issues of scope to a minimum. Invited speakers and commentators were given an opportunity to present their views as written contributions. The present seminar proceedings are essentially the result of these views. In addition, short summaries of the discussions following each session are included. Although an attempt was made to be as complete and accurate as possible in reproducing these discussions, the editors apologise if some important points or statements have been omitted. If so, the main reason is that the documentation of the discussions were based on written notes, not taped recordings. Eight longer contributions have been separately indexed

  4. Transient analysis of cutoff waveguide antenna in three-dimensional space

    International Nuclear Information System (INIS)

    Kashiwa, Tatsuya; Yoshida, Norinobu; Fukai, Ichiro

    1986-01-01

    Recently, the exciting system for electric power heating as seen in nuclear fusion plasma heating and medical purpose has been actively studied and developed. Since such system treats basically a neighborhood field, various problems unlike conventional exciting system for communication arise. In such situation, the structure having the waveguides of simple and robust construction as the main body has been proposed. In this exciting system including the condition of media, the complex distribution of a neighborhood field based on a three-dimensional structure exerts an important effect on the characteristics. Especially in large power excitation, the higher mode of relatively small power distribution cannot be neglected. Besides, also a transient field distribution exerts an important effect on the characteristics, and the time response analysis is required. In this analysis, by the three-dimensional time response analysis method using Bergeron method, the unified analysis of the total system comprising a cutoff waveguide, a coaxial exciting part and a heating region was carried out for determining a radiation neighborhood electromagnetic field by a cutoff waveguide antenna. (Kako, I.)

  5. Proceedings from the Fissile Material Cut-off seminar in Stockholm

    Energy Technology Data Exchange (ETDEWEB)

    Arbman, G. [ed.

    1998-07-01

    The Swedish Defence Research Establishment hosted an international expert seminar on the subject of verifying a prohibition of the production of fissile material for nuclear weapons purpose (cut-off) in Stockholm, June 3-5 1998. The objective of the seminar was to provide an opportunity for informal discussions among scientific and technical experts on various technical matters relating to the verification of a future Fissile Material Cut-off Treaty (FMCT). A stated aim of the seminar was to keep issues of scope to a minimum. Invited speakers and commentators were given an opportunity to present their views as written contributions. The present seminar proceedings are essentially the result of these views. In addition, short summaries of the discussions following each session are included. Although an attempt was made to be as complete and accurate as possible in reproducing these discussions, the editors apologise if some important points or statements have been omitted. If so, the main reason is that the documentation of the discussions were based on written notes, not taped recordings. Eight longer contributions have been separately indexed.

  6. Caregiver's Feeding Styles Questionnaire. Establishing cutoff points.

    Science.gov (United States)

    Hughes, Sheryl O; Cross, Matthew B; Hennessy, Erin; Tovar, Alison; Economos, Christina D; Power, Thomas G

    2012-02-01

    Researchers use the Caregiver's Feeding Styles Questionnaire (CFSQ) to categorize parent feeding into authoritative, authoritarian, indulgent, and uninvolved styles. The CFSQ assesses self-reported feeding and classifies parents using median splits which are used in a substantial body of parenting literature and allow for direct comparison across studies on dimensions of demandingness and responsiveness. No national norms currently exist for the CFSQ. This paper establishes and recommends cutoff points most relevant for low-income, minority US samples that researchers and clinicians can use to assign parents to feeding styles. Median scores for five studies are examined and the average across these studies reported. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Determining the optimal system-specific cut-off frequencies for filtering in-vitro upper extremity impact force and acceleration data by residual analysis.

    Science.gov (United States)

    Burkhart, Timothy A; Dunning, Cynthia E; Andrews, David M

    2011-10-13

    The fundamental nature of impact testing requires a cautious approach to signal processing, to minimize noise while preserving important signal information. However, few recommendations exist regarding the most suitable filter frequency cut-offs to achieve these goals. Therefore, the purpose of this investigation is twofold: to illustrate how residual analysis can be utilized to quantify optimal system-specific filter cut-off frequencies for force, moment, and acceleration data resulting from in-vitro upper extremity impacts, and to show how optimal cut-off frequencies can vary based on impact condition intensity. Eight human cadaver radii specimens were impacted with a pneumatic impact testing device at impact energies that increased from 20J, in 10J increments, until fracture occurred. The optimal filter cut-off frequency for pre-fracture and fracture trials was determined with a residual analysis performed on all force and acceleration waveforms. Force and acceleration data were filtered with a dual pass, 4th order Butterworth filter at each of 14 different cut-off values ranging from 60Hz to 1500Hz. Mean (SD) pre-fracture and fracture optimal cut-off frequencies for the force variables were 605.8 (82.7)Hz and 513.9 (79.5)Hz, respectively. Differences in the optimal cut-off frequency were also found between signals (e.g. Fx (medial-lateral), Fy (superior-inferior), Fz (anterior-posterior)) within the same test. These optimal cut-off frequencies do not universally agree with the recommendations of filtering all upper extremity impact data using a cut-off frequency of 600Hz. This highlights the importance of quantifying the filter frequency cut-offs specific to the instrumentation and experimental set-up. Improper digital filtering may lead to erroneous results and a lack of standardized approaches makes it difficult to compare findings of in-vitro dynamic testing between laboratories. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Distinct Pattern of Solar Modulation of Galactic Cosmic Rays above a High Geomagnetic Cutoff Rigidity

    Science.gov (United States)

    Mangeard, Pierre-Simon; Clem, John; Evenson, Paul; Pyle, Roger; Mitthumsiri, Warit; Ruffolo, David; Sáiz, Alejandro; Nutaro, Tanin

    2018-05-01

    Solar modulation refers to Galactic cosmic-ray variations with the ∼11 yr sunspot cycle and ∼22 yr solar magnetic cycle and is relevant to the space radiation environment and effects on Earth’s atmosphere. Its complicated dependence on solar and heliospheric conditions is only roughly understood and has been empirically modeled in terms of a single modulation parameter. Most analyses of solar modulation use neutron monitor (NM) data from locations with relatively low geomagnetic cutoff rigidity, i.e., the threshold for cosmic rays to penetrate Earth’s magnetic field. The Princess Sirindhorn Neutron Monitor at Doi Inthanon, Thailand, has the world’s highest cutoff rigidity (≈17 GV) where observations span a complete solar modulation cycle (since late 2007). The pattern of solar modulation at Doi Inthanon during 2011–2014 was qualitatively very different from that at a low geomagnetic cutoff and is not well described by the same modulation parameter. At other times, NM count rates from Doi Inthanon and McMurdo, Antarctica (cutoff ∼1 GV), were linearly correlated and confirm the observation from latitude surveys in the previous solar cycle that the slope of the correlation changes with solar magnetic polarity. Low solar magnetic tilt angles (magnetic field, which is consistent with an increase in diffusion at high rigidity short-circuiting the effects of drifts and the heliospheric current sheet.

  9. Measurement of current drive profile using electron cyclotron wave attenuation near the O-mode cut-off

    International Nuclear Information System (INIS)

    Fidone, I.

    1991-01-01

    A method for determining the radial profile of the lower-hybrid current drive in tokamaks uing electron-cyclotron attenuation of the O-mode for frequencies ω near the cut-off frequency is discussed. The basic idea is that for a given wave frequency, the cut-off plays the role of a spatial filter selecting a variable portion of the non-inductive current. It is shown that the incremental attenuation resulting from a small increase of ω displays specific features related to the current density near the cut-off point. Using the relation between the wave damping and the current density it is possible to determine the radial profile of the current drive from the wave attenuation measurements. A numerical application is also presented for plasma parameters in the reactor regime

  10. Cutoff Values of Serum Carcinoembryonic Antigen (CEA) in Normal Korean Adults and Factors Influencing Serum CEA Level

    International Nuclear Information System (INIS)

    Kim, Jong Soon; Kim, Sun Wook; Chung, June Key; Lee, Dong Soo

    1994-01-01

    Carcinoembryonic Antigen is one of most frequently checked tumor markers in cancer management. We performed statistical analysis with serum CEA data of 2626 persons who received regular health examination and were thought to be free of active disease to determine the cutoff values of serum CEA level in normal Korean adults and to study the factors influencing serum CEA levels in normal subjects. 1) The cutoff values of serum CEA in normal Korean adults in general were 9.28 ng/ml for men, 5.90 ng/ml for women. 2) Serum CEA level was influenced by age, present smoking history, sex, and abnormal findings in chest X ray. 3) Serum CEA level had no correlation with the history of amount of alcohol consumption or obesity. 4) Cutoff values of serum CEA in normal Korean adults were tabulated according to age, sex, and smoking history. Serum CEA level was influenced by age, sex, present smoking history and abnormal findings in chest X ray and cutoff values of serum CEA were tabulated according to age, sex, and smoking history.

  11. Dependence of the cutoff in lithium plasma harmonics on the delay between the prepulse and the main pulse

    International Nuclear Information System (INIS)

    Suzuki, M; Baba, M; Kuroda, H; Ganeev, R A; Bom, L B Elouga; Ozaki, T

    2012-01-01

    We demonstrated the generation of the 43rd harmonic at the wavelength of 18.49 nm (67 eV photon energy) by using laser-ablation lithium plasma irradiated by a Ti:sapphire laser pulse. We found that for low-Z material, such as lithium, the cutoff energy depends strongly on the delay time between the prepulse and the main pulse, due to rapid recombination. As a result, the maximum cutoff energy was obtained at a relatively short delay of 24 ns. From the theoretical cutoff rule and hydrodynamic simulations, we show that these harmonics were generated from singly charged lithium ions. (paper)

  12. Special nuclear materials cutoff exercise: Issues and lessons learned. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Libby, R.A.; Segal, J.E.; Stanbro, W.D.; Davis, C.

    1995-08-01

    This document is appendices D-J for the Special Nuclear Materials Cutoff Exercise: Issues and Lessons Learned. Included are discussions of the US IAEA Treaty, safeguard regulations for nuclear materials, issue sheets for the PUREX process, and the LANL follow up activity for reprocessing nuclear materials.

  13. Special nuclear materials cutoff exercise: Issues and lessons learned. Volume 3

    International Nuclear Information System (INIS)

    Libby, R.A.; Segal, J.E.; Stanbro, W.D.; Davis, C.

    1995-08-01

    This document is appendices D-J for the Special Nuclear Materials Cutoff Exercise: Issues and Lessons Learned. Included are discussions of the US IAEA Treaty, safeguard regulations for nuclear materials, issue sheets for the PUREX process, and the LANL follow up activity for reprocessing nuclear materials

  14. Casimir effect in a d-dimensional flat spacetime and the cut-off method

    International Nuclear Information System (INIS)

    Svaiter, N.F.; Svaiter, B.F.

    1989-01-01

    The CasiMir efeect in a D-dimensional spacetime produced by a Hermitian massless scalar field in the presence of a pair of perfectly reflecting parallel flat plates is discussed. The exponential cut-off regularization method is employed. The regularized vacuum energy and the Casimir energy of this field are evaluated and a detailed analysis of the divergent terms in the regularized vacuum energy is carried out. The two-dimensional version of the Casimir effect is discussed by means of the same cut-off method. A comparison between the above method and the zeta function regularization procedure is presented in a way which gives the unification between these two methods in the present case. (author) [pt

  15. Spatial and temporal variability in sedimentation rates associated with cutoff channel infill deposits: Ain River, France

    Science.gov (United States)

    Piégay, H.; Hupp, C.R.; Citterio, A.; Dufour, S.; Moulin, B.; Walling, D.E.

    2008-01-01

    Floodplain development is associated with lateral accretion along stable channel geometry. Along shifting rivers, the floodplain sedimentation is more complex because of changes in channel position but also cutoff channel presence, which exhibit specific overflow patterns. In this contribution, the spatial and temporal variability of sedimentation rates in cutoff channel infill deposits is related to channel changes of a shifting gravel bed river (Ain River, France). The sedimentation rates estimated from dendrogeomorphic analysis are compared between and within 14 cutoff channel infills. Detailed analyses along a single channel infill are performed to assess changes in the sedimentation rates through time by analyzing activity profiles of the fallout radionuclides 137Cs and unsupported 210Pb. Sedimentation rates are also compared within the channel infills with rates in other plots located in the adjacent floodplain. Sedimentation rates range between 0.65 and 2.4 cm a−1 over a period of 10 to 40 years. The data provide additional information on the role of distance from the bank, overbank flow frequency, and channel geometry in controlling the sedimentation rate. Channel infills, lower than adjacent floodplains, exhibit higher sedimentation rates and convey overbank sediment farther away within the floodplain. Additionally, channel degradation, aggradation, and bank erosion, which reduce or increase the distance between the main channel and the cutoff channel aquatic zone, affect local overbank flow magnitude and frequency and therefore sedimentation rates, thereby creating a complex mosaic of sedimentation zones within the floodplain and along the cutoff channel infills. Last, the dendrogeomorphic and 137Cs approaches are cross validated for estimating the sedimentation rate within a channel infill.

  16. Chronic kidney disease : Defining clinical cut-offs for albumin:creatinine ratio

    NARCIS (Netherlands)

    Bakker, Stephan J L

    2013-01-01

    Albuminuria is rapidly gaining recognition as a marker of the presence and of the progression of chronic kidney disease (CKD). In a new study, Naresh et al. attempt to define cut-off values for percentage change in urinary albumin:creatinine ratio that reflect changes in CKD status rather than

  17. Establishing Streptomycin Epidemiological Cut-Off Values for Salmonella and Escherichia coli

    DEFF Research Database (Denmark)

    Migura, Lourdes Garcia; Sunde, Marianne; Karlsmose, Susanne

    2011-01-01

    This study was conducted to elucidate the accuracy of the current streptomycin epidemiological cut-off value (ECOFF) for Escherichia coli and Salmonella spp. A total of 236 Salmonella enterica and 208 E. coli isolates exhibiting MICs between 4 and 32 mg/L were selected from 12 countries. Isolates...

  18. Scale interaction and arrangement in a turbulent boundary layer perturbed by a wall-mounted cylindrical element

    Science.gov (United States)

    Tang, Zhanqi; Jiang, Nan

    2018-05-01

    This study reports the modifications of scale interaction and arrangement in a turbulent boundary layer perturbed by a wall-mounted circular cylinder. Hot-wire measurements were executed at multiple streamwise and wall-normal wise locations downstream of the cylindrical element. The streamwise fluctuating signals were decomposed into large-, small-, and dissipative-scale signatures by corresponding cutoff filters. The scale interaction under the cylindrical perturbation was elaborated by comparing the small- and dissipative-scale amplitude/frequency modulation effects downstream of the cylinder element with the results observed in the unperturbed case. It was obtained that the large-scale fluctuations perform a stronger amplitude modulation on both the small and dissipative scales in the near-wall region. At the wall-normal positions of the cylinder height, the small-scale amplitude modulation coefficients are redistributed by the cylinder wake. The similar observation was noted in small-scale frequency modulation; however, the dissipative-scale frequency modulation seems to be independent of the cylindrical perturbation. The phase-relationship observation indicated that the cylindrical perturbation shortens the time shifts between both the small- and dissipative-scale variations (amplitude and frequency) and large-scale fluctuations. Then, the integral time scale dependence of the phase-relationship between the small/dissipative scales and large scales was also discussed. Furthermore, the discrepancy of small- and dissipative-scale time shifts relative to the large-scale motions was examined, which indicates that the small-scale amplitude/frequency leads the dissipative scales.

  19. Prevalensi Sarkopenia pada Lansia di Komunitas (Community Dwelling berdasarkan Dua Nilai Cut-off Parameter Diagnosis

    Directory of Open Access Journals (Sweden)

    Vitriana

    2016-09-01

    Full Text Available Sarcopenia, aging muscle mass loss, and function syndromes can lead to decreased quality of life and increased elderly mortality. The availability of various screening methods and operational definitions in different studies has produced different findings of sarcopenia prevalence. The purpose of this study was to discover the prevalence of sarcopenia in Indonesian community-dwelling elderly based on muscle mass measured by bioimpedance analysis, handgrip strength using hand dynamometer, and physical performance based on six minutes walking test with two different cut-off point parameters of sarcopenia, i.e. the cut-off point recommended by Asian Working Group for Sarcopenia (AWGS and the cut-off point based on the reference used in Taiwan elderly population reference due to the lack of references for Indonesian elderly population. A cross-sectional study was conducted to 229 participants (71 men and 158 women from the community-dwelling elderly population between August and December 2014 in Bandung and Jatinangor. The results of the study showed that the sarcopenia prevalence in this study based on AWGS was 9.1% (7.4% in men and 1.7% in women while the prevalence based on the Taiwan reference revealed a prevalence of 40.6% (20.1% in men and 20.5% in women. This highly different prevalences shows the importance of defining a specific cut-off point for elderly population in community-dwelling Indonesia to get a more accurate sarcopenia prevalence.

  20. Local time and cutoff rigidity dependences of storm time increase associated with geomagnetic storms

    International Nuclear Information System (INIS)

    Kudo, S.; Wada, M.; Tanskanen, P.; Kodama, M.

    1987-01-01

    The cosmic ray increases due to considerable depressions of cosmic ray cutoff rigidity during large geomagnetic storms are investigated. Data from a worldwide network of cosmic ray neutron monitors are analyzed for 17 geomagnetic storms which occurred in the quiet phase of the solar activity cycle during 1966-1978. As expected from the longitudinal asymmetry of the low-altitude geomagnetic field during large geomagnetic storms, a significant local time dependence of the increment in the cosmic ray during large geomagnetic storms, a significant local time dependence of the increment in the cosmic ray intensity is obtained. It is shown that the maximum phases of the local time dependence occur at around 1800 LT and that the amplitudes of the local time dependence are consistent with presently available theoretical estimates. The dependence of the increment on the cutoff rigidity is obtained for both the local time dependent part and the local time independent part of the storm time increase. The local time independent part, excluding the randomizing local time dependent part, shows a clear-cut dependence on cutoff rigidity which is consistent with theoretical estimates

  1. The geomagnetic cutoff rigidities at high latitudes for different solar wind and geomagnetic conditions

    International Nuclear Information System (INIS)

    Chu, W.; Univ. of Chinese Academy of Sciences, Beijing; Qin, G.

    2016-01-01

    Studying the access of the cosmic rays (CRs) into the magnetosphere is important to understand the coupling between the magnetosphere and the solar wind. In this paper we numerically studied CRs' magnetospheric access with vertical geomagnetic cutoff rigidities using the method proposed by Smart and Shea (1999). By the study of CRs' vertical geomagnetic cutoff rigidities at high latitudes we obtain the CRs' window (CRW) whose boundary is determined when the vertical geomagnetic cutoff rigidities drop to a value lower than a threshold value. Furthermore, we studied the area of CRWs and found out they are sensitive to different parameters, such as the z component of interplanetary magnetic field (IMF), the solar wind dynamic pressure, AE index, and Dst index. It was found that both the AE index and Dst index have a strong correlation with the area of CRWs during strong geomagnetic storms. However, during the medium storms, only AE index has a strong correlation with the area of CRWs, while Dst index has a much weaker correlation with the area of CRWs. This result on the CRW can be used for forecasting the variation of the cosmic rays during the geomagnetic storms.

  2. Secondary proton production at small atmospheric depths as a function of the geomagnetic cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Papini, P. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Grimani, C. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); Stephens, S.A. [Tata Institute of Fundamental Research, Bombay (International Commission on Radiation Units and Measurements)

    1995-09-01

    A detailed calculation of the energy spectrum of secondary protons in the atmosphere is being carried out in the energy range 20 MeV - 40 GeV. In this calculation, it is taken into account all processes leading to the production of secondary protons as a function of the atmospheric depth has been calculated using all relevant energy loss processes. In this paper, it is examine the effect of the geomagnetic cut-off on the spectral shape of secondary protons specially at energies below the geomagnetic cut-off for small atmospheric depths.

  3. Secondary proton production at small atmospheric depths as a function of the geomagnetic cut-off

    International Nuclear Information System (INIS)

    Papini, P.; Grimani, C.; Stephens, S.A.

    1995-01-01

    A detailed calculation of the energy spectrum of secondary protons in the atmosphere is being carried out in the energy range 20 MeV - 40 GeV. In this calculation, it is taken into account all processes leading to the production of secondary protons as a function of the atmospheric depth has been calculated using all relevant energy loss processes. In this paper, it is examine the effect of the geomagnetic cut-off on the spectral shape of secondary protons specially at energies below the geomagnetic cut-off for small atmospheric depths

  4. Characteristics of wall pressure over wall with permeable coating

    Energy Technology Data Exchange (ETDEWEB)

    Song, Woo Seog; Shin, Seungyeol; Lee, Seungbae [Inha Univ., Incheon (Korea, Republic of)

    2012-11-15

    Fluctuating wall pressures were measured using an array of 16 piezoelectric transducers beneath a turbulent boundary layer. The coating used in this experiment was an open cell, urethane type foam with a porosity of approximately 50 ppi. The ultimate objective of the coating is to provide a mechanical filter to reduce the wall pressure fluctuations. The ultimate objective of the coating is to provide a mechanical filter to reduce the wall pressure fluctuations. The boundary layer on the flat plate was measured by using a hot wire probe, and the CPM method was used to determine the skin friction coefficient. The wall pressure autospectra and streamwise wavenumber frequency spectra were compared to assess the attenuation of the wall pressure field by the coating. The coating is shown to attenuate the convective wall pressure energy. However, the relatively rough surface of the coating in this investigation resulted in a higher mean wall shear stress, thicker boundary layer, and higher low frequency wall pressure spectral levels compared to a smooth wall.

  5. Cutoff for extensions of massive gravity and bi-gravity

    International Nuclear Information System (INIS)

    Matas, Andrew

    2016-01-01

    Recently there has been interest in extending ghost-free massive gravity, bi-gravity, and multi-gravity by including non-standard kinetic terms and matter couplings. We first review recent proposals for this class of extensions, emphasizing how modifications of the kinetic and potential structure of the graviton and modifications of the coupling to matter are related. We then generalize existing no-go arguments in the metric language to the vielbein language in second-order form. We give an ADM argument to show that the most promising extensions to the kinetic term and matter coupling contain a Boulware–Deser ghost. However, as recently emphasized, we may still be able to view these extensions as effective field theories below some cutoff scale. To address this possibility, we show that there is a decoupling limit where a ghost appears for a wide class of matter couplings and kinetic terms. In particular, we show that there is a decoupling limit where the linear effective vielbein matter coupling contains a ghost. Using the insight we gain from this decoupling limit analysis, we place an upper bound on the cutoff for the linear effective vielbein coupling. This result can be generalized to new kinetic interactions in the vielbein language in second-order form. Combined with recent results, this provides a strong uniqueness argument on the form of ghost-free massive gravity, bi-gravity, and multi-gravity. (paper)

  6. BANKRUPTCY PREDICTION MODEL WITH ZETAc OPTIMAL CUT-OFF SCORE TO CORRECT TYPE I ERRORS

    Directory of Open Access Journals (Sweden)

    Mohamad Iwan

    2005-06-01

    This research has successfully attained the following results: (1 type I error is in fact 59,83 times more costly compared to type II error, (2 22 ratios distinguish between bankrupt and non-bankrupt groups, (3 2 financial ratios proved to be effective in predicting bankruptcy, (4 prediction using ZETAc optimal cut-off score predicts more companies filing for bankruptcy within one year compared to prediction using Hair et al. optimum cutting score, (5 Although prediction using Hair et al. optimum cutting score is more accurate, prediction using ZETAc optimal cut-off score proved to be able to minimize cost incurred from classification errors.

  7. [Mini Mental State Examination (MMSE): determination of cutoff scores according to age and educational level].

    Science.gov (United States)

    Solias, A; Skapinakis, P; Degleris, N; Pantoleon, M; Katirtzoglou, E; Politis, A

    2014-01-01

    For the last 38 years, Mini Mental State Examination (MMSE) has been widely used as a dementia screening measure in everyday clinical practice as well as in both cohort and cross-sectional studies. Its validity and reliability for the Greek population has explicitly been documented. However, the effect of age and education on the subject's performance makes it necessary to reckon them in the estimation of the "cutoff score". The purpose of this study is to estimate the prevalence of dementia in Greek population and determine the "cutoff score" by age and education-corrected norms. Cross sectional study of 630 patients older than 55 years, who live independently in Ilion and Helioupolis Municipalities was conducted, 27.3% of the subjects tested in the study were diagnosed with memory disorder according to their MMSE scores and the validation for the Greek population. The effect of age and education to the subjects' performance was statistically significant (p=.000). The use of standard "cutoff score" was not proved to be useful for the personalized interpretation of the results, as documented by the fact that older individuals with lower education had a poorer performance relatively to younger, highly educated subjects. Comparatively to the group age of 55-60 years, the odds ratio after the age of 75 years varies from 2.58 to 4.91. Regarding the variable factor of education, the odds ratio for the first degree education graduates decreases from 1.43 to 3.19 for the third degree education graduates in comparison with the group of illiterates. In conclusion, the use of the "cutoff score" algorithm and the simultaneous estimation of age and education effect on MMSE score may prove useful for the proper evaluation of MMSE performance. According to the age and education of examine candidates in the community and the primary care, we propose the use of the 25th percentile as a more useful cutoff score in order to decrease the false positive results.

  8. Revisiting AdS/CFT at a finite radial cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Gautam; Nayak, Pranjal [Department of Theoretical Physics,Tata Institute of Fundamental Research, Mumbai 400005 (India)

    2016-12-22

    We revisit AdS/CFT at a finite radial cut-off, specifically in the context of double trace perturbations, O{sub n}= O(x)(∂{sup 2}){sup n}O(x), with arbitrary powers n. As well-known, the standard GKPW prescription, applied to a finite radial cut-off, leads to contact terms in correlators. de Haro et al. http://dx.doi.org/10.1007/s002200100381 introduced bulk counterterms to remove these. This prescription, however, yields additional terms in the correlator corresponding to spurious double trace deformations. Further, if we view the GKPW prescription coupled with the prescription in http://dx.doi.org/10.1007/s002200100381, in terms of a boundary wavefunction, we find that it is incompatible with radial Schrödinger evolution (in the spirit of holographic Wilsonian RG). We consider a more general wavefunction satisfying the Schrödinger equation, and find that generically such wavefunctions generate both (a) double trace deformations and (b) contact terms. However, we find that there exist special choices of these wavefunctions, amounting to a new AdS/CFT prescription at a finite cut-off, so that both (a) and (b) are removed and we obtain a pure power law behaviour for the correlator. We compare these special wavefunctions with a specific RG scheme in field theory. We give a geometric interpretation of these wavefunctions; these correspond to some specific smearing of boundary points in the Witten diagrams. We present a comprehensive calculation of exact double-trace beta-functions for all couplings O{sub n} and match with a holographic computation using the method described above. The matching works with a mapping between the field theory and bulk couplings; such a map is highly constrained because the beta-functions are quadratic and exact on both sides. Our discussions include a generalization of the standard double-trace Wilson-Fisher flow to the space of the infinite number of couplings.

  9. Brick walls for black holes in AdS/CFT

    Directory of Open Access Journals (Sweden)

    Norihiro Iizuka

    2015-06-01

    Full Text Available We study the 't Hooft's brick wall model for black holes in a holographic context. The brick wall model suggests that without an appropriate near horizon IR cut-off, the free energy of the probe fields shows the divergence due to the large degenerate states near the horizons. After studying the universal nature of the divergence in various holographic settings in various dimensions, we interpret the nature of the divergence in a holographic context. The free energy divergence is due to the large degeneracy and continuity of the low energy spectrum in the boundary theory at the deconfinement phase. These divergence and continuity should be removed by finite N effects, which make the spectrum discrete even at the deconfinement phase. On the other hand, in the bulk, these degenerate states are localized near the horizon, and the universal divergence of these degenerate states implies that the naive counting of the degrees of freedom in bulk should be modified once we take into account the non-perturbative quantum gravity effects near the horizon. Depending on the microscopic degrees of freedom, the position, where the effective field theory description to count the states breaks down, has different Planck scale dependence. It also implies the difficulty to have an electron like gauge-singlet elementary field in the boundary theory Lagrangian. These singlet fields are at most composite fields, because they show divergent free energy, suggesting a positive power of N at the deconfinement phase.

  10. Corotation torques in the solar nebula - the cutoff function

    International Nuclear Information System (INIS)

    Ward, W.R.

    1989-01-01

    The behavior of high-order corotation resonances in a disk of finite thickness is examined. The torque exerted at an mth-order resonance is determined by employing a vertically averaged disturbing function, and the ratio of this torque to that exerted on a cold, two-dimensional disk is identified as the so-called torque cutoff function. This function is then used to calculate contributions from the corotation torques to eccentricity variations of a perturber's orbit assumed orbiting in the disk. 11 references

  11. Possible connection between the location of the cutoff in the cosmic microwave background spectrum and the equation of state of dark energy.

    Science.gov (United States)

    Enqvist, Kari; Sloth, Martin S

    2004-11-26

    We investigate a possible connection between the suppression of the power at low multipoles in the cosmic microwave background (CMB) spectrum and the late time acceleration. We show that, assuming a cosmic IR/UV duality between the UV cutoff and a global infrared cutoff given by the size of the future event horizon, the equation of state of the dark energy can be related to the apparent cutoff in the CMB spectrum. The present limits on the equation of state of dark energy are shown to imply an IR cutoff in the CMB multipole interval of 9>l>8.5.

  12. Derivation of the cut-off length from the quantum quadratic enhancement of a mass in vacuum energy constant Lambda

    Science.gov (United States)

    Fukushima, Kimichika; Sato, Hikaru

    2018-04-01

    Ultraviolet self-interaction energies in field theory sometimes contain meaningful physical quantities. The self-energies in such as classical electrodynamics are usually subtracted from the rest mass. For the consistent treatment of energies as sources of curvature in the Einstein field equations, this study includes these subtracted self-energies into vacuum energy expressed by the constant Lambda (used in such as Lambda-CDM). In this study, the self-energies in electrodynamics and macroscopic classical Einstein field equations are examined, using the formalisms with the ultraviolet cut-off scheme. One of the cut-off formalisms is the field theory in terms of the step-function-type basis functions, developed by the present authors. The other is a continuum theory of a fundamental particle with the same cut-off length. Based on the effectiveness of the continuum theory with the cut-off length shown in the examination, the dominant self-energy is the quadratic term of the Higgs field at a quantum level (classical self-energies are reduced to logarithmic forms by quantum corrections). The cut-off length is then determined to reproduce today's tiny value of Lambda for vacuum energy. Additionally, a field with nonperiodic vanishing boundary conditions is treated, showing that the field has no zero-point energy.

  13. Development of short-form and screening cutoff point of the Smartphone Addiction Inventory (SPAI-SF).

    Science.gov (United States)

    Lin, Yu-Hsuan; Pan, Yuan-Chien; Lin, Sheng-Hsuan; Chen, Sue-Huei

    2017-06-01

    Smartphone addiction is considered a form of technological addiction that has attracted increasing attention. The present study developed and validated the short-form Smartphone Addiction Inventory (SPAI-SF) and established cutoff point for screening smartphone addiction based on diagnostic criteria established by psychiatric interview. A total of 268 participants completed an online survey that collected demographic data, smartphone use behaviours, and responses to the 26-item SPAI. Each participant also completed a psychiatric interview. Confirmatory factor analysis (CFA) revealed that the 10-item SPAI-SF replicated the structure of original 26-item SPAI accurately, yielding a four-factor model consisting of compulsive behaviour, functional impairment, withdrawal, and tolerance. For maximal diagnostic accuracy, a cutoff point of 24/25 best discriminated cases of smartphone addiction from diagnostic negatives. The present findings suggest that both the 26-item SPAI and SPAI-SF manifest the four constructs of behavioural addiction and the characteristics of smartphone addiction. The cutoff point determined by psychiatrists' diagnostic interview will be useful for clinical screening and epidemiologic research. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Reinforcement mechanism of multi-anchor wall with double wall facing

    Science.gov (United States)

    Suzuki, Kouta; Kobayashi, Makoto; Miura, Kinya; Konami, Takeharu; Hayashi, Taketo

    2017-10-01

    The reinforced soil wall has high seismic performance as generally known. However, the seismic behavior has not been clarified accurately yet, especially on multi-anchor wall with double wall facing. Indefinite behavior of reinforced soil wall during earthquake make us complicated in case with adopting to the abutment, because of arrangement of anchor plate as reinforcement often different according to the width of roads. In this study, a series of centrifuge model tests were carried out to investigate the reinforcement mechanism of multi anchor wall with double wall facing from the perspective of the vertical earth pressure. Several types of reinforce arrangement and rigid wall were applied in order to verify the arch function in the reinforced regions. The test results show unique behavior of vertical earth pressure, which was affected by arch action. All the vertical earth pressure placed behind facing panel, are larger than that of middle part between facing panel despite of friction between backfill and facing panel. Similar results were obtained in case using rigid wall. On the other hands, the vertical earth pressure, which were measured at the 3cm high from bottom of model container, shows larger than that of bottom. This results show the existence of arch action between double walls. In addition, it implies that the wall facing of such soil structure confined the backfill as pseudo wall, which is very reason that the multi anchor wall with double wall facing has high seismic performance.

  15. Selecting a cutoff point for a developmental screening test based on overall diagnostic indices and total expected utilities of professional preferences.

    Science.gov (United States)

    Liao, Hua-Fang; Cheng, Ling-Yee; Hsieh, Wu-Shiun; Yang, Ming-Chin

    2010-03-01

    A cutoff point in a test with sounded validity and professional preferences can help to make an accurate clinical decision. This study aimed to determine a cutoff point between two strategies for a developmental screening checklist (referred to as Taipei II). Cutoff point A was set as one or more item failed and cutoff point B was set as two or more items failed or one or more marked item failed. This study was based on the total expected utilities of professional preferences and overall diagnostic indices. A self-administered questionnaire was developed to collect the estimated utility from professionals involved in early childhood interventions (n = 81) regarding four screening outcomes (probabilities of true positive, false positive, true negative, or false negative) and costs. The total expected utilities were calculated from the probabilities of four screening outcomes and utility values. The diagnostic odds ratio was higher for strategy B (695 and 209, respectively) than that of strategy A (184 and 150, respectively) when using the Taipei II on children under 3 years of age and age 3 and over. Strategy B also had a higher median total expected utilities score than strategy A (0.78 vs. 0.72 for children or = 3). If only one cutoff point can be chosen, the authors suggest that clinicians should choose cutoff point B when using the Taipei II for screening. However, two cutoff points of Taipei II, a combination of strategy A and B, can also be used clinically. 2010 Formosan Medical Association & Elsevier. Published by Elsevier B.V. All rights reserved.

  16. Clinically Relevant Cut-off Points for the Diagnosis of Sarcopenia in Older Korean People.

    Science.gov (United States)

    Choe, Yu-Ri; Joh, Ju-Youn; Kim, Yeon-Pyo

    2017-11-09

    The optimal criteria applied to older Korean people have not been defined. We aimed to define clinically relevant cut-off points for older Korean people and to compare the predictive validity with other definitions of sarcopenia. Nine hundred and sixteen older Koreans (≥65 years) were included in this cross-sectional observational study. We used conditional inference tree analysis to determine cut-off points for height-adjusted grip strength (GS) and appendicular skeletal muscle mass (ASM), for use in the diagnosis of sarcopenia. We then compared the Korean sarcopenia criteria with the Foundation for the National Institutes of Health and Asian Working Group for Sarcopenia criteria, using frailty, assessed with the Korean Frailty Index, as an outcome variable. For men, a residual GS (GSre) of ≤ 0.25 was defined as weak, and a residual ASM (ASMre) of ≤ 1.29 was defined as low. Corresponding cut-off points for women were a GSre of ≤ 0.17 and an ASMre of ≤ 0.69. GSre and ASMre values were adjusted for height. In logistic regression analysis with new cut-off points, the adjusted odds ratios for pre-frail or frail status in the sarcopenia group were 3.23 (95% confidence interval [CI] 1.33-7.83) for the men and 1.74 (95% CI 0.91-3.35) for the women. In receiver operating characteristic curve analysis, the unadjusted area under the curve for Korean sarcopenia criteria in men and women were 0.653 and 0.608, respectively (p sarcopenia in older Korean people. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Investigating Systematic Errors of the Interstellar Flow Longitude Derived from the Pickup Ion Cutoff

    Science.gov (United States)

    Taut, A.; Berger, L.; Drews, C.; Bower, J.; Keilbach, D.; Lee, M. A.; Moebius, E.; Wimmer-Schweingruber, R. F.

    2017-12-01

    Complementary to the direct neutral particle measurements performed by e.g. IBEX, the measurement of PickUp Ions (PUIs) constitutes a diagnostic tool to investigate the local interstellar medium. PUIs are former neutral particles that have been ionized in the inner heliosphere. Subsequently, they are picked up by the solar wind and its frozen-in magnetic field. Due to this process, a characteristic Velocity Distribution Function (VDF) with a sharp cutoff evolves, which carries information about the PUI's injection speed and thus the former neutral particle velocity. The symmetry of the injection speed about the interstellar flow vector is used to derive the interstellar flow longitude from PUI measurements. Using He PUI data obtained by the PLASTIC sensor on STEREO A, we investigate how this concept may be affected by systematic errors. The PUI VDF strongly depends on the orientation of the local interplanetary magnetic field. Recently injected PUIs with speeds just below the cutoff speed typically form a highly anisotropic torus distribution in velocity space, which leads to a longitudinal transport for certain magnetic field orientation. Therefore, we investigate how the selection of magnetic field configurations in the data affects the result for the interstellar flow longitude that we derive from the PUI cutoff. Indeed, we find that the results follow a systematic trend with the filtered magnetic field angles that can lead to a shift of the result up to 5°. In turn, this means that every value for the interstellar flow longitude derived from the PUI cutoff is affected by a systematic error depending on the utilized magnetic field orientations. Here, we present our observations, discuss possible reasons for the systematic trend we discovered, and indicate selections that may minimize the systematic errors.

  18. Insulin Resistance Distribution and Cut-Off Value in Koreans from the 2008-2010 Korean National Health and Nutrition Examination Survey

    Science.gov (United States)

    Yun, Kyung-Jin; Han, Kyungdo; Kim, Mee Kyoung; Park, Yong-Moon; Baek, Ki-Hyun; Song, Ki-Ho; Kwon, Hyuk-Sang

    2016-01-01

    Background We sought to identify the distribution and cut-off value of the ‘homeostasis model assessment of insulin resistance’ (HOMA-IR) according to gender and menopausal status for metabolic syndrome in Koreans. Methods Data were from the Korean National Health and Nutrition Examination Survey in 2008–2010. The subjects included adults aged 20 years or older. We excluded participants who had diabetes or fasting serum glucose ≥ 7 mmol/L. Finally, 11,121 subjects (4,911 men, 3,597 premenopausal women, 2,613 postmenopausal women) were enrolled. The modified Adult Treatment Panel III criteria were used to define metabolic syndrome. Results The mean HOMA-IR was 2.11 (2.07–2.15) for men, 2.0 (1.97–2.04) for premenopausal women, and 2.14 (2.2–2.19) for postmenopausal women. The first cut-off values in men, premenopausal women, and postmenopausal women were 2.23 (sensitivity 70.6%, specificity 66.9%), 2.39 (sensitivity 72.3%, specificity 76.4%), and 2.48 (sensitivity 51.9%, specificity 80.2%), respectively. Based on the first HOMA-IR cut-off value, the prevalence of metabolic syndrome was 22.9% in men, 13.7% in premenopausal women, and 51.6% in postmenopausal women. The second cut-off value was around 3.2 in all three groups. Based on the second HOMA-IR cut-off value, the prevalence of metabolic syndrome was 50.8% in men, 42.5% in premenopausal women, and 71.6% in postmenopausal women. Conclusion In conclusion, the first cut-off values for HOMA-IR were 2.2–2.5 and the second cut-off value was 3.2 in Korea. The distribution of HOMA-IR showed differences according to gender and menopausal status. When we apply HOMA-IR, we should consider gender, menopausal status, and the prevalence of metabolic syndrome. PMID:27128847

  19. Twisted mass, overlap and Creutz fermions. Cut-off effects at tree-level of perturbation theory

    International Nuclear Information System (INIS)

    Cichy, K.; Kujawa, A.; Jansen, K.; Shindler, A.

    2008-02-01

    We study cutoff effects at tree-level of perturbation theory for maximally twisted mass Wilson, overlap and the recently proposed Creutz fermions. We demonstrate that all three kind of lattice fermions exhibit the expected O(a 2 ) scaling behaviour in the lattice spacing. In addition, the sizes of these cutoff effects are comparable for the three kinds of lattice fermions considered here. Furthermore, we analyze situations when twisted mass fermions are not exactly at maximal twist and when overlap fermions are studied in comparison to twisted mass fermions when the quark masses are not matched. (orig.)

  20. Projection systems with a cut-off line for automotive applications

    Science.gov (United States)

    Kloos, G.; Eichhorn, K.

    2005-08-01

    The lighting systems of a car provide a variety of challenges from the point of view of illumination science and technology. Engineering work in this field has to deal both with reflector and lens design as well as with opto-mechanical design and sensor technology. It has direct implications on traffic safety and the efficiency in which energy is used. Therefore, these systems are continuously improved and optimized. In this context, adaptive systems that we investigate for automotive applications gain increasing importance. The properties of the light distribution in the vicinity of the cut-off line are of key importance for the safe and efficient operation of automotive headlamps. An alternative approach is proposed to refine the description of these properties in an attempt to make it more quantitative. This description is intended to facilitate intercomparison between different systems and/or to study environmental influences on the cut-off line of a system under investigation. Designing projection systems it is necessary to take a delicate trade-off between efficiency, light-distribution characteristics, mechanical boundary conditions, and legal requirements into account. Considerations and results on optical properties of three-axial reflectors in dependence of layout parameters will be given. They can serve as a guideline for the optical workshop and for free-form optimization.

  1. Human papillomavirus testing in primary cervical screening and the cut-off level for hybrid capture 2 tests

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Bonde, Jesper; Njor, Sisse Helle

    2011-01-01

    To determine the trade-off between the sensitivity and the specificity for high grade cervical intraepithelial neoplasia at hybrid capture 2 cut-off values above the standard = 1 relative light units/cut-off level (rlu/co).......To determine the trade-off between the sensitivity and the specificity for high grade cervical intraepithelial neoplasia at hybrid capture 2 cut-off values above the standard = 1 relative light units/cut-off level (rlu/co)....

  2. Efficient Closed Form Cut-Off Planes and Propagation Planes Characteristics for Dielectric Slab Loaded Boundary Value Problems

    OpenAIRE

    Zafar, Junaid

    2012-01-01

    The geometrical relationship between the cut-off and propagating planes of any waveguide system is a prerequisite for any design process. The characterization of cut-off planes and optimisation are challenging for numerical methods, closed-form solutions are always preferred. In this paper Maxwells coupled field equations are used to characterise twin E-plane and H-plane slab loaded boundary value problems. The single mode bandwidths and dispersion characteristics of these structures are pres...

  3. Single-chain statistics and the upper wave-vector cutoff in polymer blends

    International Nuclear Information System (INIS)

    Holyst, R.; Vilgis, T.A.

    1994-01-01

    We derive the equation for the single-chain correlation function in polymer blends. The chains in the incompressible blend have a radius of gyration smaller than the radius of gyration for ideal chains. The chains shrink progressively as we approach the critical temperature T c . The correction responsible for shrinking is proportional to 1/ √N , where N is the polymerization index. At T=T c and for N=1000, the size of the chain has been estimated to be 10% smaller than the size of the ideal coil. The estimate relies on the appropriate cutoff. In the limit of N→∞ the chains approach the random walk limit. Additionally, we propose in this paper a self-consistent determination of the radius of gyration and the upper wave-vector cutoff. Our model is free from any divergences such as were encountered in the previous mean-field studies; we make an estimate of the chain size at the true critical temperature and not the mean-field one

  4. Fast beam cut-off method in RF-knockout extraction for spot-scanning

    CERN Document Server

    Furukawa, T

    2002-01-01

    An irradiation method with magnetic scanning has been developed in order to provide accurate irradiation even for an irregular target shape. The scanning method has strongly required a lower ripple of the beam spill and a faster response to beam-on/off in slow extraction from a synchrotron ring. At HIMAC, RF-knockout extraction has utilized a bunched beam to reduce the beam-spill ripple. Therefore, particles near the resonance can be spilled out from the separatrices by synchrotron oscillation as well as by a transverse RF field. From this point of view, a fast beam cut-off method has been proposed and verified by both simulations and experiments. The maximum delay from the beam cut-off signal to beam-off has been improved to around 60 mu s from 700 mu s by a usual method. Unwanted dose has been considerably reduced by around a factor of 10 compared with that by the usual method.

  5. Assessment of energy savings and of side effects associated with consumption cutoffs. Complete report + abridged version

    International Nuclear Information System (INIS)

    2016-03-01

    As France has been the first European country to implement a legal and regulatory framework which acknowledges the role of cut-off operators, and promotes their direct participation to markets, this report aims at preparing an evolution of this framework, notably by focusing on the notion of energy saving. It highlights the importance of definitions regarding levels of consumption deferment and of energy saving associated with consumption cutoffs. The report first analyses the context: assessment of energy savings associated with consumption cutoffs, discussion of the existence or absence of a typical profile of consumption deferment, and definition of a consumption deferment rate, importance of these works for cut-off integration into the electric power system. It proposes a presentation of the present status of knowledge on energy savings and side effects, defines the energy saving rate, and discusses the sensitivity of this rate to calculation parameters. The next part presents the method adopted to analyse results obtained during experiments. The obtained results are then discussed by distinguishing those obtained in the industrial sector, in the tertiary sector, and in the residential sector. Economic studies are then reported regarding the impact of a wrong choice for the deferment rate on market mechanism rules, and the impact of an explicit taking of the deferment into account. Appendices contain detailed presentations of some specific aspects of these assessments and studies. An abridged version of the report is then provided

  6. Wind tunnels with adapted walls for reducing wall interference

    Science.gov (United States)

    Ganzer, U.

    1979-01-01

    The basic principle of adaptable wind tunnel walls is explained. First results of an investigation carried out at the Aero-Space Institute of Berlin Technical University are presented for two dimensional flexible walls and a NACA 0012 airfoil. With five examples exhibiting very different flow conditions it is demonstrated that it is possible to reduce wall interference and to avoid blockage at transonic speeds by wall adaptation.

  7. On the Cut-off Point for Combinatorial Group Testing

    DEFF Research Database (Denmark)

    Fischer, Paul; Klasner, N.; Wegener, I.

    1999-01-01

    is answered by 1 if Q contains at least one essential object and by 0 otherwise. In the statistical setting the objects are essential, independently of each other, with a given probability p combinatorial setting the number k ... group testing is equal to p* = 12(3 - 5), i.e., the strategy of testing each object individually minimizes the average number of queries iff p >= p* or n = 1. In the combinatorial setting the worst case number of queries is of interest. It has been conjectured that the cut-off point of combinatorial...

  8. Tentative Colistin Epidemiological Cut-Off Value for Salmonella spp

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Torpdahl, Mia; Zachariasen, Camilla

    2012-01-01

    . Interestingly, Salmonella Dublin and Salmonella Enteritidis belong to the same O-group (O:1, 9,12), suggesting that surface lipopolysaccharides (LPS) of the cell (O-antigen) play a role in colistin susceptibility. The epidemiological cut-off value of >2 mg/L for colistin suggested by European Committee...... on Antimicrobial Susceptibility Testing (EUCAST) is placed inside the distribution for both Salmonella Dublin and Salmonella Enteritidis. All tested Salmonella Dublin isolates, regardless of MIC colistin value, had identical pmrA and pmrB sequences. Missense mutations were found only in pmrA in one Salmonella...

  9. Inverse measurement of wall pressure field in flexible-wall wind tunnels using global wall deformation data

    Science.gov (United States)

    Brown, Kenneth; Brown, Julian; Patil, Mayuresh; Devenport, William

    2018-02-01

    The Kevlar-wall anechoic wind tunnel offers great value to the aeroacoustics research community, affording the capability to make simultaneous aeroacoustic and aerodynamic measurements. While the aeroacoustic potential of the Kevlar-wall test section is already being leveraged, the aerodynamic capability of these test sections is still to be fully realized. The flexibility of the Kevlar walls suggests the possibility that the internal test section flow may be characterized by precisely measuring small deflections of the flexible walls. Treating the Kevlar fabric walls as tensioned membranes with known pre-tension and material properties, an inverse stress problem arises where the pressure distribution over the wall is sought as a function of the measured wall deflection. Experimental wall deformations produced by the wind loading of an airfoil model are measured using digital image correlation and subsequently projected onto polynomial basis functions which have been formulated to mitigate the impact of measurement noise based on a finite-element study. Inserting analytic derivatives of the basis functions into the equilibrium relations for a membrane, full-field pressure distributions across the Kevlar walls are computed. These inversely calculated pressures, after being validated against an independent measurement technique, can then be integrated along the length of the test section to give the sectional lift of the airfoil. Notably, these first-time results are achieved with a non-contact technique and in an anechoic environment.

  10. Cut-off values of distal forearm bone density for the diagnosis of ...

    African Journals Online (AJOL)

    Background: The objective of this study was to establish a triage cut-off point or threshold for peripheral bone mineral density (BMD), applicable to black postmenopausal women, and that could be used as a screening method to differentiate between women with normal BMD, and those with possible central osteoporosis.

  11. Finite element elasto-plastic analysis of thin walled structures of reinforced concrete as applied to reactor facilities

    International Nuclear Information System (INIS)

    Fujita, F.; Tsuboi, Y.

    1981-01-01

    The authors developed a new program of elasto-plastic analysis of reinforced concrete shells, in which the simplest model of shell element and an orthotropic constitutive relation are adopted, and verified its validity with reference to the results of model experiments of containers and box-wall structures with various loading conditions. For the two-dimensional stress-strain relationship of concrete, an orthotropic nonlinear formula proposed by one of the authors was adopted. For concrete, the octahedral shear failure and tension cut-off criteria were also imposed. The Kirchhoff-Love's assumptions were assumed to be valid for the whole range of the analysis and the layered approach of elasto-plastic stiffness evaluation. Derivation of the shell element is outlined with examination of its accuracy in elastic range and the assumption of elasto-plastic material property and the procedure of nonlinear analysis are described. As examples, the method is applied to the analysis of a cylindrical container and a box-wall structure. Comparison of the computed results with the corresponding experimental data indicates the applicability of the proposed method. (orig./HP)

  12. Nucleon structure in lattice QCD with dynamical domain-wall fermions quarks

    International Nuclear Information System (INIS)

    Huey-Wen Lin; Shigemi Ohta

    2006-01-01

    We report RBC and RBC/UKQCD lattice QCD numerical calculations of nucleon electroweak matrix elements with dynamical domain-wall fermions (DWF) quarks. The first, RBC, set of dynamical DWF ensembles employs two degenerate flavors of DWF quarks and the DBW2 gauge action. Three sea quark mass values of 0.04, 0.03 and 0.02 in lattice units are used with about 200 gauge configurations each. The lattice cutoff is about 1.7 GeV and the spatial volume is about (1.9 fm) 3 . Despite the small volume, the ratio of the isovector vector and axial charges g A /g V and that of structure function moments u-d / Δ u-Δ d are in agreement with experiment, and show only very mild quark mass dependence. The second, RBC/UK, set of ensembles employs one strange and two degenerate (up and down) dynamical DWF quarks and Iwasaki gauge action. The strange quark mass is set at 0.04, and three up/down mass values of 0.03, 0.02 and 0.01 in lattice units are used. The lattice cutoff is about 1.6 GeV and the spatial volume is about (3.0 fm) 3 . Even with preliminary statistics of 25-30 gauge configurations, the ratios g A /g V and u-d / Δu - Δd are consistent with experiment and show only very mild quark mass dependence. Another structure function moment, d 1 , though yet to be renormalized, appears small in both sets

  13. NUCLEON STRUCTURE IN LATTICE QCD WITH DYNAMICAL DOMAIN--WALL FERMIONS QUARKS

    International Nuclear Information System (INIS)

    LIN, H.W.; OHTA, S.

    2006-01-01

    We report RBC and RBC/UKQCD lattice QCD numerical calculations of nucleon electroweak matrix elements with dynamical domain-wall fermions (DWF) quarks. The first, RBC, set of dynamical DWF ensembles employs two degenerate flavors of DWF quarks and the DBW2 gauge action. Three sea quark mass values of 0.04, 0.03 and 0.02 in lattice units are used with 220 gauge configurations each. The lattice cutoff is a -1 ∼ 1.7GeV and the spatial volume is about (1.9fm) 3 . Despite the small volume, the ratio of the isovector vector and axial charges g A /g V and that of structure function moments u-d / Δu-Δd are in agreement with experiment, and show only very mild quark mass dependence. The second, RBC/UK, set of ensembles employs one strange and two degenerate (up and down) dynamical DWF quarks and Iwasaki gauge action. The strange quark mass is set at 0.04, and three up/down mass values of 0.03, 0.02 and 0.01 in lattice units are used. The lattice cutoff is a -1 ∼ 1.6GeV and the spatial volume is about (3.0fm) 3 . Even with preliminary statistics of 25-30 gauge configurations, the ratios g A /g V and u-d / Δu-Δd are consistent with experiment and show only very mild quark mass dependence. Another structure function moment, d 1 , though yet to be renormalized, appears small in both sets

  14. Meteor head echo altitude distributions and the height cutoff effect studied with the EISCAT HPLA UHF and VHF radars

    Directory of Open Access Journals (Sweden)

    A. Westman

    2004-04-01

    Full Text Available Meteor head echo altitude distributions have been derived from data collected with the EISCAT VHF (224MHz and UHF (930MHz high-power, large-aperture (HPLA radars. At the high-altitude end, the distributions cut off abruptly in a manner reminiscent of the trail echo height ceiling effect observed with classical meteor radars. The target dimensions are shown to be much smaller than both the VHF and the UHF probing wavelengths, but the cutoff heights for the two systems are still clearly different, the VHF cutoff being located several km above the UHF one. A single-collision meteor-atmosphere interaction model is used to demonstrate that meteors in the (1.3–7.2µg mass range will ionise such that critical electron density at 224MHz is first reached at or around the VHF cutoff altitude and critical density at 930MHz will be reached at the UHF cutoff altitude. The observed seasonal variation in the cutoff altitudes is shown to be a function of the seasonal variation of atmospheric density with altitude. Assuming that the electron density required for detection is in the order of the critical density, the abrupt altitude cutoffs can be explained as a consequence of the micrometeoroid joint size-speed distribution dropping off so fast at the large-mass, high-velocity end that above a certain altitude the number of detectable events becomes vanishingly small. Conversely, meteors at the low-mass end of the distribution will be gradually retarded such that the ionisation they generate never reaches critical density. These particles will remain unobservable.Key words. Radio science (instruments and techniques – Interplatery physics (interplanetary dust – General or miscellaneous (new fields

  15. Age-related differences in recommended anthropometric cut-off point validity to identify cardiovascular risk factors in ostensibly healthy women.

    Science.gov (United States)

    Subramoney, Sreevidya; Björkelund, Cecilia; Guo, Xinxin; Skoog, Ingmar; Bosaeus, Ingvar; Lissner, Lauren

    2014-12-01

    To investigate validity of widely recommended anthropometric and total fat percentage cut-off points in screening for cardiovascular risk factors in women of different ages. A population-based sample of 1002 Swedish women aged 38, 50, 75 (younger, middle-aged and elderly, respectively) underwent anthropometry, health examinations and blood tests. Total fat was estimated (bioimpedance) in 670 women. Sensitivity, specificity of body mass index (BMI; ≥25 and ≥30), waist circumference (WC; ≥80 cm and ≥88 cm) and total fat percentage (TF; ≥35%) cut-off points for cardiovascular risk factors (dyslipidaemias, hypertension and hyperglycaemia) were calculated for each age. Cut-off points yielding high sensitivity together with modest specificity were considered valid. Women reporting hospital admission for cardiovascular disease were excluded. The sensitivity of WC ≥80 cm for one or more risk factors was ~60% in younger and middle-aged women, and 80% in elderly women. The specificity of WC ≥80 cm for one or more risk factors was 69%, 57% and 40% at the three ages (p < .05 for age trends). WC ≥80 cm yielded ~80% sensitivity for two or more risk factors across all ages. However, specificity decreased with increasing age (p < .0001), being 33% in elderly. WC ≥88 cm provided better specificity in elderly women. BMI and TF % cut-off points were not better than WC. Validity of recommended anthropometric cut-off points in screening asymptomatic women varies with age. In younger and middle-age, WC ≥80 cm yielded high sensitivity and modest specificity for two or more risk factors, however, sensitivity for one or more risk factor was less than optimal. WC ≥88 cm showed better validity than WC ≥80 cm in elderly. Our results support age-specific screening cut-off points for women. © 2014 the Nordic Societies of Public Health.

  16. Identification of Phosphohistone H3 Cutoff Values Corresponding to Original WHO Grades but Distinguishable in Well-Differentiated Gastrointestinal Neuroendocrine Tumors

    Directory of Open Access Journals (Sweden)

    Min Jeong Kim

    2018-01-01

    Full Text Available Mitotic counts in the World Health Organization (WHO grading system have narrow cutoff values. True mitotic figures, however, are not always distinguishable from apoptotic bodies and darkly stained nuclei, complicating the ability of the WHO grading system to diagnose well-differentiated neuroendocrine tumors (NETs. The mitosis-specific marker phosphohistone H3 (PHH3 can identify true mitoses and grade tumors reliably. The aim of this study was to investigate the correspondence of tumor grades, as determined by PHH3 mitotic index (MI and mitotic counts according to WHO criteria, and to determine the clinically relevant cutoffs of PHH3 MI in rectal and nonrectal gastrointestinal NETs. Mitotic counts correlated with both the Ki-67 labeling index and PHH3 MI, but the correlation with PHH3 MI was slightly higher. The PHH3 MI cutoff ≥4 correlated most closely with original WHO grades for both rectal NETs. A PHH3 MI cutoff ≥4, which could distinguish between G1 and G2 tumors, was associated with disease-free survival in patients with rectal NETs, whereas that cutoff value showed marginal significance for overall survival in patient with rectal NETs. In conclusion, the use of PHH3 ≥4 correlated most closely with original WHO grades.

  17. The dischargeable cut-off score of Oswestry Disability Index (ODI) in the inpatient care for low back pain with disability.

    Science.gov (United States)

    Park, Sang-Won; Shin, Ye-Sle; Kim, Hye-Jin; Lee, Jin-Ho; Shin, Joon-Shik; Ha, In-Hyuk

    2014-10-01

    The admission due to low back pain (LBP) became prevalent cause of international economic losses. Since LBP patients with disability are often subject to inpatient care, it is important to determine the appropriate time of discharge. The purpose of this study is to set the cut-off value of appropriate Oswestry Disability Index (ODI) at the time of discharge. Of 1,394 LBP patients admitted in hospital specialized in spinal disease, 774 eligible patients with disability were included in this study. And several clinical variables including numerical rating score, ODI, satisfaction level were observed during the hospital stay. We considered satisfaction level as an important factor for discharge, categorized patients into satisfied group and dissatisfied group. Through the statistical analysis, appropriate factor for determining dischargeable patients satisfied with their current condition and its cut-off value of ODI were found. And proper predictors for the cut-off value were extracted statistically and logically from a pool of several clinical indexes. The ODI at the time of discharge was most accurate in determining dischargeable patients. The cut-off value of ODI was 30. Predictors were ODI questions 4 and 6. We set the cut-off value of dischargeable ODI for LBP inpatient with disability and found its predictor.

  18. X-ray Spectral Survey of WGACAT Quasars, II: Optical and Radio Properties of Quasars with Low Energy X-ray Cut-offs

    OpenAIRE

    Elvis, Martin; Fiore, Fabrizio; Giommi, Paolo; Padovani, Paolo

    1997-01-01

    We have selected quasars with X-ray colors suggestive of a low energy cut-off, from the ROSAT PSPC pointed archive. We examine the radio and optical properties of these 13 quasars. Five out of the seven quasars with good optical spectra show associated optical absorption lines, with two having high delta-v candidate systems. Two other cut-off quasars show reddening associated with the quasar. We conclude that absorption is highly likely to be the cause of the X-ray cut-offs, and that the abso...

  19. Detecting congenital hypothyroidism with newborn screening: the relevance of thyroid-stimulating hormone cutoff values.

    Science.gov (United States)

    Silvestrin, Stela Maris; Leone, Claudio; Leone, Cléa Rodrigues

    To assess the prevalence of congenital hypothyroidism and the ability of various neonatal thyroid-stimulating hormone (TSHneo) cutoff values to detect this disease. This cohort study was based on the retrospective collection of information available from the Reference Service for Newborn Screening database for all live births from January 1, 2010, to December 31, 2012, assessed using the Newborn Screening Program of a Brazilian state, Brazil. The infants were divided into two groups: I - Control: infants with normal newborn screening tests and II - Study: infants with congenital hypothyroidism. Analysis included comparing the TSHneo levels from both groups. A receiver operating characteristic (ROC) curve was constructed to assess the TSHneo cutoff values. Using a TSHneo cutoff value of 5.0μIU/mL, 50 out of 111,705 screened infants had diagnosis of congenital hypothyroidism (prevalence 1:2234 live births). The ROC curve showed that TSHneo value of 5.03μIU/mL had 100% sensitivity and the greatest associated specificity (93.7%). The area under the curve was 0.9898 (pvalue of 5.0μIU/mL adopted by the Newborn Screening Program of a Brazilian state was the most appropriate for detecting congenital hypothyroidism and most likely explains the high prevalence that was found. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Thermodynamics of interacting holographic dark energy with the apparent horizon as an IR cutoff

    International Nuclear Information System (INIS)

    Sheykhi, Ahmad

    2010-01-01

    As soon as an interaction between holographic dark energy and dark matter is taken into account, the identification of an IR cutoff with the Hubble radius H -1 , in a flat universe, can simultaneously drive accelerated expansion and solve the coincidence problem. Based on this, we demonstrate that in a non-flat universe the natural choice for the IR cutoff could be the apparent horizon radius, r-tilde A =1/√(H 2 +k/a 2 ). We show that any interaction of dark matter with holographic dark energy, whose infrared cutoff is set by the apparent horizon radius, implies an accelerated expansion and a constant ratio of the energy densities of both components thus solving the coincidence problem. We also verify that for a universe filled with dark energy and dark matter, the Friedmann equation can be written in the form of the modified first law of thermodynamics, dE = T h dS h + WdV, at the apparent horizon. In addition, the generalized second law of thermodynamics is fulfilled in a region enclosed by the apparent horizon. These results hold regardless of the specific form of dark energy and interaction term. Our study might reveal that in an accelerating universe with spatial curvature, the apparent horizon is a physical boundary from the thermodynamical point of view.

  1. On cutoff effects in lattice QCD from short to long distances

    International Nuclear Information System (INIS)

    Della Morte, Michele; Sommer, Rainer; Takeda, Shinji

    2009-01-01

    We discuss kinematical enhancements of cutoff effects at short and intermediate distances. Starting from a pedagogical example with periodic boundary conditions, we switch to the case of the Schroedinger functional, where the theoretical analysis is checked by precise numerical data with N f =2 dynamical O(a)-improved Wilson quarks. Finally we present an improved determination of the renormalization of the axial current in that theory

  2. On cutoff effects in lattice QCD from short to long distances

    International Nuclear Information System (INIS)

    Della Morte, Michele; Sommer, Rainer; Takeda, Shinji

    2008-07-01

    We discuss kinematical enhancements of cutoff effects at short and intermediate distances. Starting from a pedagogical example with periodic boundary conditions, we switch to the case of the Schroedinger functional, where the theoretical analysis is checked by precise numerical data with N f =2 dynamical O(a)-improved Wilson quarks. Finally we present an improved determination of the renormalization of the axial current in that theory. (orig.)

  3. ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test

    Directory of Open Access Journals (Sweden)

    Anahita Sanaei Dashti

    2012-03-01

    Full Text Available Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis.

  4. Body mass index and waist-to-height ratio cut-offs as predictors of high blood pressure in adolescents

    Directory of Open Access Journals (Sweden)

    Kurnia Febriana

    2015-04-01

    Full Text Available Background: Obesity is associated with increased risk for high blood pressure (BP. Although a routine BP measurement is indicated for all children visiting pediatric practice, recognition of children particularly at risk may save times. The aim of this study was to assess the cut-off point for body mass index (BMI and waist-to-height ratio (WHtR to predict high BP in adolescents. Methods: We conducted a cross-sectional study on 928 children aged 11 to 16 years in Yogyakarta. BP were measured using standard technique described by The Fourth Report on The Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. BMI was adjusted for age and sex using the WHO 2007 growth reference. WHtR was ratio of waist circumference related to height in centimeters. Receiver operating characteristic (ROC curves were used to estimate the best cut-offs. Results: The best cut-off point for BMI-for-age Z-score (BMIZ to predict high BP was 0.51 with sensitivity and specificity of 82% (95% CI = 78-86 and 76% (95% CI = 67-78 for systolic BP and sensitivity and specificity of 82% (95% CI = 78-86 and 72% (95% CI = 68-76 for diastolic BP. The best cut-off point for WHtR was 0.45, with sensitivity of 76% (95% CI = 67-78 and specificity of 74% (95% CI = 71-79 for systolic BP and sensitivity of 76% (95% CI = 72-80 and specificity of 70% (95% CI = 61-75 for diastolic BP.Conclusion: BMIZ of 0.51 and WHtR of 0.45 are the best cut-off point to predict high BP in adolescents.

  5. The cutoff values of indirect indices for measuring insulin resistance for metabolic syndrome in Korean children and adolescents

    Directory of Open Access Journals (Sweden)

    Jun Woo Kim

    2016-09-01

    Full Text Available PurposeThe prevalence rates of metabolic syndrome (MetS and percentile distribution of insulin resistance (IR among Korean children and adolescents were investigated. The cutoff values of IR were calculated to identify high-risk MetS groups.MethodsData from 3,313 Korean subjects (1,756 boys and 1,557 girls, aged 10–18 years were included from the Korean National Health and Nutrition Examination Survey conducted during 2007–2010. Three different sets of criteria for MetS were used. Indirect measures of IR were homeostasis model assessment (HOMA-IR and triglyceride and glucose (TyG index. The cutoff values of the HOMA-IR and TyG index were obtained from the receiver operation characteristic curves.ResultsAccording to the MetS criteria of de Ferranti el al., Cook et al., and the International Diabetes Federation, the prevalence rates in males and females were 13.9% and 12.3%, 4.6% and 3.6%, and 1.4% and 1.8%, respectively. Uses these 3 criteria, the cutoff values of the HOMA-IR and TyG index were 2.94 and 8.41, 3.29 and 8.38, and 3.54 and 8.66, respectively. The cutoff values using each of the 3 criteria approximately corresponds to the 50th–75th, 75th, and 75th–90th percentiles of normal HOMA-IR and TyG index levels.ConclusionThis study describes the prevalence rates of MetS in Korean children and adolescents, an index of IR, and the cutoff values for MetS with the aim of detecting high-risk groups. The usefulness of these criteria needs to be verified by further evaluation.

  6. Wall-based identification of coherent structures in wall-bounded turbulence

    Science.gov (United States)

    Sanmiguel Vila, C.; Flores, O.

    2018-04-01

    During the last decades, a number of reduced order models based on coherent structures have been proposed to describe wall-bounded turbulence. Many of these models emphasize the importance of coherent wall-normal velocity eddies (ν-eddies), which drive the generation of the very long streamwise velocity structures observed in the logarithmic and outer region. In order to use these models to improve our ability to control wall-bounded turbulence in realistic applications, these ν-eddies need to be identified from the wall in a non-intrusive way. In this paper, the possibility of using the pressure signal at the wall to identify these ν-eddies is explored, analyzing the cross-correlation between the wall-normal velocity component and the pressure fluctuations at the wall in a DNS of a turbulent channel flow at Reτ = 939. The results show that the cross-correlation has a region of negative correlation upstream, and a region of positive correlation backwards. In the spanwise direction the correlation decays monotonously, except very close to the wall where a change of sign of the correlation coefficient is observed. Moreover, filtering the pressure fluctuations at the wall in space results in an increase of the region where the cross-correlation is strong, both for the positively and the negatively correlated regions. The use of a time filter for the pressure fluctuations at the wall yields different results, displacing the regions of strong correlation without changing much their sizes. The results suggest that space-filtering the pressure at the wall is a feasible way to identify ν-eddies of different sizes, which could be used to trigger turbulent control strategies.

  7. Rise time of proton cut-off energy in 2D and 3D PIC simulations

    Science.gov (United States)

    Babaei, J.; Gizzi, L. A.; Londrillo, P.; Mirzanejad, S.; Rovelli, T.; Sinigardi, S.; Turchetti, G.

    2017-04-01

    The Target Normal Sheath Acceleration regime for proton acceleration by laser pulses is experimentally consolidated and fairly well understood. However, uncertainties remain in the analysis of particle-in-cell simulation results. The energy spectrum is exponential with a cut-off, but the maximum energy depends on the simulation time, following different laws in two and three dimensional (2D, 3D) PIC simulations so that the determination of an asymptotic value has some arbitrariness. We propose two empirical laws for the rise time of the cut-off energy in 2D and 3D PIC simulations, suggested by a model in which the proton acceleration is due to a surface charge distribution on the target rear side. The kinetic energy of the protons that we obtain follows two distinct laws, which appear to be nicely satisfied by PIC simulations, for a model target given by a uniform foil plus a contaminant layer that is hydrogen-rich. The laws depend on two parameters: the scaling time, at which the energy starts to rise, and the asymptotic cut-off energy. The values of the cut-off energy, obtained by fitting 2D and 3D simulations for the same target and laser pulse configuration, are comparable. This suggests that parametric scans can be performed with 2D simulations since 3D ones are computationally very expensive, delegating their role only to a correspondence check. In this paper, the simulations are carried out with the PIC code ALaDyn by changing the target thickness L and the incidence angle α, with a fixed a0 = 3. A monotonic dependence, on L for normal incidence and on α for fixed L, is found, as in the experimental results for high temporal contrast pulses.

  8. A HARD X-RAY POWER-LAW SPECTRAL CUTOFF IN CENTAURUS X-4

    Energy Technology Data Exchange (ETDEWEB)

    Chakrabarty, Deepto; Nowak, Michael A. [MIT Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Tomsick, John A.; Boggs, Steven E.; Craig, William W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Grefenstette, Brian W.; Fürst, Felix; Harrison, Fiona A.; Rana, Vikram [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Psaltis, Dimitrios [Department of Astronomy, University of Arizona, Tucson, AZ 85721 (United States); Bachetti, Matteo; Barret, Didier [Observatoire Midi-Pyrénées, Université de Toulouse III - Paul Sabatier, F-31400 Toulouse (France); Christensen, Finn E. [Division of Astrophysics, National Space Institute, Technical University of Denmark, DK-2800 Lyngby (Denmark); Hailey, Charles J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Kaspi, Victoria M. [Department of Physics, McGill University, Montreal, PQ H3A 2T8 (Canada); Miller, Jon M. [Department of Astronomy, University of Michigan, Ann Arbor, MI 48109 (United States); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Wik, Daniel R.; Zhang, William W. [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Wilms, Jörn, E-mail: deepto@mit.edu [Dr. Karl-Remeis-Sternwarte and Erlangen Centre for Astroparticle Physics, Universität Erlangen-Nürnberg, D-96049 Bamberg (Germany)

    2014-12-20

    The low-mass X-ray binary (LMXB) Cen X-4 is the brightest and closest (<1.2 kpc) quiescent neutron star transient. Previous 0.5-10 keV X-ray observations of Cen X-4 in quiescence identified two spectral components: soft thermal emission from the neutron star atmosphere and a hard power-law tail of unknown origin. We report here on a simultaneous observation of Cen X-4 with NuSTAR (3-79 keV) and XMM-Newton (0.3-10 keV) in 2013 January, providing the first sensitive hard X-ray spectrum of a quiescent neutron star transient. The 0.3-79 keV luminosity was 1.1×10{sup 33} D{sub kpc}{sup 2} erg s{sup –1}, with ≅60% in the thermal component. We clearly detect a cutoff of the hard spectral tail above 10 keV, the first time such a feature has been detected in this source class. We show that thermal Comptonization and synchrotron shock origins for the hard X-ray emission are ruled out on physical grounds. However, the hard X-ray spectrum is well fit by a thermal bremsstrahlung model with kT{sub e} = 18 keV, which can be understood as arising either in a hot layer above the neutron star atmosphere or in a radiatively inefficient accretion flow. The power-law cutoff energy may be set by the degree of Compton cooling of the bremsstrahlung electrons by thermal seed photons from the neutron star surface. Lower thermal luminosities should lead to higher (possibly undetectable) cutoff energies. We compare Cen X-4's behavior with PSR J1023+0038, IGR J18245–2452, and XSS J12270–4859, which have shown transitions between LMXB and radio pulsar modes at a similar X-ray luminosity.

  9. [Research progress on the clinical value of Ki-67 in breast cancer and its cut-off definition].

    Science.gov (United States)

    Chen, Qing; Wu, Kejin

    2015-08-01

    Ki-67 has an important application value in clinical practice. However, it is still a little tough in clinical application because of the debate on the cut-off definition of Ki-67 index. This review summarizes most studies on the prognostic and predictive value of Ki-67, analyzes the reasons for the discrepancies among the studies cited, and presents the necessity and clinical significance of scientifically defining the cut-off of Ki-67 index, providing a theoretical basis for Ki-67 in clinical application.

  10. Evaluating the effects of cutoffs and treatment of long-range electrostatics in protein folding simulations.

    Directory of Open Access Journals (Sweden)

    Stefano Piana

    Full Text Available The use of molecular dynamics simulations to provide atomic-level descriptions of biological processes tends to be computationally demanding, and a number of approximations are thus commonly employed to improve computational efficiency. In the past, the effect of these approximations on macromolecular structure and stability has been evaluated mostly through quantitative studies of small-molecule systems or qualitative observations of short-timescale simulations of biological macromolecules. Here we present a quantitative evaluation of two commonly employed approximations, using a test system that has been the subject of a number of previous protein folding studies--the villin headpiece. In particular, we examined the effect of (i the use of a cutoff-based force-shifting technique rather than an Ewald summation for the treatment of electrostatic interactions, and (ii the length of the cutoff used to determine how many pairwise interactions are included in the calculation of both electrostatic and van der Waals forces. Our results show that the free energy of folding is relatively insensitive to the choice of cutoff beyond 9 Å, and to whether an Ewald method is used to account for long-range electrostatic interactions. In contrast, we find that the structural properties of the unfolded state depend more strongly on the two approximations examined here.

  11. Defining Glaucomatous Optic Neuropathy from a Continuous Measure of Optic Nerve Damage - The Optimal Cut-off Point for Risk-factor Analysis in Population-based Epidemiology

    NARCIS (Netherlands)

    Ramdas, Wishal D.; Rizopoulos, Dimitris; Wolfs, Roger C. W.; Hofman, Albert; de Jong, Paulus T. V. M.; Vingerling, Johannes R.; Jansonius, Nomdo M.

    2011-01-01

    Purpose: Diseases characterized by a continuous trait can be defined by setting a cut-off point for the disease measure in question, accepting some misclassification. The 97.5th percentile is commonly used as a cut-off point. However, it is unclear whether this percentile is the optimal cut-off

  12. Wall Shear Stress, Wall Pressure and Near Wall Velocity Field Relationships in a Whirling Annular Seal

    Science.gov (United States)

    Morrison, Gerald L.; Winslow, Robert B.; Thames, H. Davis, III

    1996-01-01

    The mean and phase averaged pressure and wall shear stress distributions were measured on the stator wall of a 50% eccentric annular seal which was whirling in a circular orbit at the same speed as the shaft rotation. The shear stresses were measured using flush mounted hot-film probes. Four different operating conditions were considered consisting of Reynolds numbers of 12,000 and 24,000 and Taylor numbers of 3,300 and 6,600. At each of the operating conditions the axial distribution (from Z/L = -0.2 to 1.2) of the mean pressure, shear stress magnitude, and shear stress direction on the stator wall were measured. Also measured were the phase averaged pressure and shear stress. These data were combined to calculate the force distributions along the seal length. Integration of the force distributions result in the net forces and moments generated by the pressure and shear stresses. The flow field inside the seal operating at a Reynolds number of 24,000 and a Taylor number of 6,600 has been measured using a 3-D laser Doppler anemometer system. Phase averaged wall pressure and wall shear stress are presented along with phase averaged mean velocity and turbulence kinetic energy distributions located 0.16c from the stator wall where c is the seal clearance. The relationships between the velocity, turbulence, wall pressure and wall shear stress are very complex and do not follow simple bulk flow predictions.

  13. On cutoff effects in lattice QCD from short to long distances

    Energy Technology Data Exchange (ETDEWEB)

    Della Morte, Michele [CERN, Physics Department, TH Division, Geneva (Switzerland); Sommer, Rainer [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Takeda, Shinji [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik

    2008-07-15

    We discuss kinematical enhancements of cutoff effects at short and intermediate distances. Starting from a pedagogical example with periodic boundary conditions, we switch to the case of the Schroedinger functional, where the theoretical analysis is checked by precise numerical data with N{sub f}=2 dynamical O(a)-improved Wilson quarks. Finally we present an improved determination of the renormalization of the axial current in that theory. (orig.)

  14. Ambiguous walls

    DEFF Research Database (Denmark)

    Mody, Astrid

    2012-01-01

    The introduction of Light Emitting Diodes (LEDs) in the built environment has encouraged myriad applications, often embedded in surfaces as an integrated part of the architecture. Thus the wall as responsive luminous skin is becoming, if not common, at least familiar. Taking into account how walls...... have encouraged architectural thinking of enclosure, materiality, construction and inhabitation in architectural history, the paper’s aim is to define new directions for the integration of LEDs in walls, challenging the thinking of inhabitation and program. This paper introduces the notion...... of “ambiguous walls” as a more “critical” approach to design [1]. The concept of ambiguous walls refers to the diffuse status a lumious and possibly responsive wall will have. Instead of confining it can open up. Instead of having a static appearance, it becomes a context over time. Instead of being hard...

  15. The continuous cut-off method and the relativistic scattering of spin-1/2 particles

    International Nuclear Information System (INIS)

    Dolinszky, T.

    1979-07-01

    A high energy formula, obtained in the framework of the continuous cut-off approach, is shown to improve the correctness of the standard phase shift expression for Dirac scattering by two orders of magnitude in energy. (author)

  16. Reducing cutoff effects in maximally twisted lattice QCD close to the chiral limit

    International Nuclear Information System (INIS)

    Frezzotti, R.; Papinutto, M.; Rossi, G.C.; Istituto Nazionale di Fisica Nucleare, Rome; Deutsches Elektronen-Synchrotron

    2005-03-01

    When analyzed in terms of the Symanzik expansion, the expectation values of multi-local (gauge-invariant) operators with non-trivial continuum limit exhibit in maximally twisted lattice QCD ''infrared divergent'' cutoff effects of the type a 2k /(m π 2 ) h , 2k ≥ h ≥ 1, which become numerically dangerous when the pion mass gets small. We prove that, if the critical mass counter-term is chosen in some ''optimal'' way or, alternatively, the action is O(a) improved a la Symanzik, the leading cutoff effects of this kind (i.e. those with h = 2k) can all be eliminated. Once this is done, the remaining next-to-leading ''infrared divergent'' effects are only of the kind a 2 (a 2 /m π 2 ) k , k ≥ 1. This implies that the continuum extrapolation of lattice results is smooth at least down to values of the quark mass, m q , satisfying the order of magnitude inequality m q > a 2 Λ QCD 3 . (orig.)

  17. The Portuguese version of the Outcome Questionnaire (OQ-45): Normative data, reliability, and clinical significance cut-offs scores.

    Science.gov (United States)

    Machado, Paulo P P; Fassnacht, Daniel B

    2015-12-01

    The Outcome Questionnaire (OQ-45) is one of the most extensively used standardized self-report instruments to monitor psychotherapy outcomes. The questionnaire is designed specifically for the assessment of change during psychotherapy treatments. Therefore, it is crucial to provide norms and clinical cut-off values for clinicians and researchers. The current study aims at providing study provides norms, reliability indices, and clinical cut-off values for the Portuguese version of the scale. Data from two large non-clinical samples (high school/university, N = 1,669; community, N = 879) and one clinical sample (n = 201) were used to investigate psychometric properties and derive normative data for all OQ-45 subscales and the total score. Significant and substantial differences were found for all subscales between the clinical and non-clinical sample. The Portuguese version also showed adequate reliabilities (internal consistency, test-retest), which were comparable to the original version. To assess individual clinical change, clinical cut-off values and reliable change indices were calculated allowing clinicians and researchers to monitor and evaluate clients' individual change. The Portuguese version of the OQ-45 is a reliable instrument with comparable Portuguese norms and cut-off scores to those from the original version. This allows clinicians and researchers to use this instrument for evaluating change and outcome in psychotherapy. This study provides norms for non-clinical and clinical Portuguese samples and investigates the reliability (internal consistency and test-retest) of the OQ-45. Cut-off values and reliable change index are provided allowing clinicians to evaluate clinical change and clients' response to treatment, monitoring the quality of mental health care services. These can be used, in routine clinical practice, as benchmarks for treatment progress and to empirically base clinical decisions such as continuation of treatment or considering

  18. Serum anti-PLA2R antibody as a diagnostic biomarker of idiopathic membranous nephropathy: The optimal cut-off value for Chinese patients.

    Science.gov (United States)

    Liu, Yipeng; Li, Xuan; Ma, Chaoqun; Wang, Ping; Liu, Ju; Su, Hong; Zhuo, Hao; Kong, Xianglei; Xu, Dayu; Xu, Dongmei

    2018-01-01

    The M-type phospholipase A2 receptor (PLA2R) is a specific target autoantigen identified in idiopathic membranous nephropathy (IMN). The autoantibody against PLA2R (anti-PLA2R) may be used to diagnose IMN. However, the appropriate diagnosis cut-off value for Chinese patients with IMN has not been established. In total, 119 patients who underwent renal biopsy (57 patients with IMN and 62 patients with non-IMN glomerulonephritis) and 22 healthy individuals were recruited for our observation study from Qianfoshan Hospital between September 2011 and March 2016. The serum concentration of anti-PLA2R was measured using a quantitative enzyme-linked immunosorbent assay (ELISA). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and receiver operating characteristic (ROC) curve of anti-PLA2R in diagnosing IMN were analysed based on the ELISA detection. The sensitivity, specificity, PPV, and NPV of anti-PLA2R in the diagnosis of IMN in the Chinese patients were 82.5, 75, 69.1, and 86.3% for the 2RU/ml cut-off value; 78.9, 91.7, 86.5, and 86.5% for the 2.6RU/ml cut-off value; 59.6, 95.2, 89.5, and 77.7% for the 14RU/ml cut-off value; 50.9, 96.4, 90.6, and 74.3% for the 20RU/ml cut-off value; and 47.4, 97.6, 93.1, and 73.2% for the 40RU/ml cut-off value, respectively. The area under the ROC curve was 0.879. The cut-off value of 2.6RU/ml is recommended for the use of anti-PLA2R for the diagnosis of IMN in Chinese patients based on the ELISA. Copyright © 2017. Published by Elsevier B.V.

  19. High-R Walls for Remodeling: Wall Cavity Moisture Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J.; Kochkin, V.

    2012-12-01

    The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

  20. High-R Walls for Remodeling. Wall Cavity Moisture Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Wiehagen, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Kochkin, V. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2012-12-01

    The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

  1. Grading the intensity of nondental orofacial pain: identification of cutoff points for mild, moderate, and severe pain

    Directory of Open Access Journals (Sweden)

    Brailo V

    2015-02-01

    Full Text Available Vlaho Brailo,1 Joanna M Zakrzewska2 1Department of Oral Medicine, School of Dental Medicine, University of Zagreb, Zagreb, Croatia; 2Facial Pain Unit, Division of Diagnostic, Surgical and Medical Sciences, Eastman Dental Hospital, UCLH NHS Foundation Trust/University College London, London, UK Background: When assessing pain in clinical practice, clinicians often label pain as mild, moderate, and severe. However, these categories are not distinctly defined, and are often used arbitrarily. Instruments for pain assessment use more sophisticated scales, such as a 0–10 numerical rating scale, and apart from pain intensity assess pain-related interference and disability. The aim of the study was to identify cutoff points for mild, moderate, and severe nondental orofacial pain using a numerical rating scale, a pain-related interference scale, and a disability measurement. Materials and methods: A total of 245 patients referred to the Facial Pain Unit in London were included in the study. Intensity and pain-related interference were assessed by the Brief Pain Inventory. Pain-related disability was assessed by the Chronic Graded Pain Scale. Average pain intensity (0–10 was classified into nine schemes with varying cutoff points of mild, moderate, and severe pain. The scheme with the most significant intergroup difference, expressed by multivariate analysis of variance, provided the cutoffs between mild, moderate, and severe pain. Results: The combination that showed the greatest intergroup differences for all patients was scheme 47 (mild 1–4, moderate 5–7, severe 8–10. The same combination provided the greatest intergroup differences in subgroups of patients with temporomandibular disorder and chronic idiopathic facial pain, respectively. Among the trigeminal neuralgia patients alone, the combination with the highest intergroup differences was scheme 48 (mild 1–4, moderate 5–8, severe 9–10. Conclusion: The cutoff points established in

  2. Design Dependent Cutoff Frequency of Nanotransistors Near the Ultimate Performance Limit

    Science.gov (United States)

    Kordrostami, Zoheir; Sheikhi, M. Hossein; Zarifkar, Abbas

    2012-12-01

    We have studied the effect of different structural designs of double gate MOSFETs (DG-MOSFETs) and carbon nanotube field effect transistors (CNTFETs) on the cutoff frequency (fT). The effects of metallic contacts with Schottky barriers, gate work function, dual material gate (DMG), halo doped channel and lightly doped drain and source (LDDS) architectures on the fT have been investigated for DG-MOSFETs and CNTFETs and the design dependent fT for both types of transistors has been studied for the first time. The simulations are based on the Schrödinger-Poisson solvers developed for each nanotransistor separately. The ballistic limit has been studied as the ultimate performance limit of the DG-MOSFETs and CNTFETs. The results of this paper, for the first time, show how some designations used for modification of short channel effects or current-voltage characteristics affect the fT. The results revealed that the cutoff frequencies of both types of the transistors exhibit the same behavior with changing design parameters. We have shown that the Schottky barriers, parasitic capacitances and halo doping reduce the fT and have proposed the DMG and LDDS artchitectures as ways to increase the fT for DG-MOSFETs and CNTFETs for the first time.

  3. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  4. Bifurcation of the Quark Self-Energy: Infra-Red and Ultra-Violet Cut-Offs

    NARCIS (Netherlands)

    Atkinson, D.; Johnson, P. W.

    1987-01-01

    The quark self-energy in massless QCD is studied in the approximation that both the quark-gluon vertex and the gluon propagator remain bare. It is shown that chiral invariance is not spontaneously broken at a critical coupling λc>0, unless both infrared and ultraviolet cutoffs are introduced.

  5. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, Wolfgang [Multiorgan Screening Foundation, Frankfurt (Germany); University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany); University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg [University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Wiedemann, Baerbel [University Hospital Dresden, Institute of Medical Informatics and Biometrics, Dresden (Germany); Wehrmann, Ursula [University Hospital Dresden, Clinic and Policlinic of Surgery, Dresden (Germany); Koch, Arne; Abolmaali, Nasreddin [University Hospital Dresden, Oncoray, Dresden (Germany); Toussaint, Todd; Luboldt, Hans-Joachim [Multiorgan Screening Foundation, Frankfurt (Germany); Middendorp, Markus; Gruenwald, Frank [University Hospital Frankfurt, Department of Nuclear Medicine, Frankfurt (Germany); Aust, Daniela [University Hospital Dresden, Department of Pathology, Dresden (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany)

    2010-09-15

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas {>=}10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV{sub max} was {>=}5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV{sub max}. FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV{sub max}{>=} 5 improves the accuracy. (orig.)

  6. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg; Wiedemann, Baerbel; Wehrmann, Ursula; Koch, Arne; Abolmaali, Nasreddin; Toussaint, Todd; Luboldt, Hans-Joachim; Middendorp, Markus; Gruenwald, Frank; Aust, Daniela; Vogl, Thomas J.

    2010-01-01

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas ≥10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV max was ≥5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV max . FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV max ≥ 5 improves the accuracy. (orig.)

  7. Rising damp in building walls: the wall base ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, A.S.; Delgado, J.M.P.Q.; Freitas, V.P. de [Faculdade de Engenharia da Universidade do Porto, Laboratorio de Fisica das Construcoes (LFC), Departamento de Engenharia Civil, Porto (Portugal)

    2012-12-15

    This work intends to validate a new system for treating rising damp in historic buildings walls. The results of laboratory experiments show that an efficient way of treating rising damp is by ventilating the wall base, using the HUMIVENT technique. The analytical model presented describes very well the observed features of rising damp in walls, verified by laboratory tests, who contributed for a simple sizing of the wall base ventilation system that will be implemented in historic buildings. (orig.)

  8. Definition of new cut-offs of BMI and waist circumference based on body composition and insulin resistance: differences between children, adolescents and adults.

    Science.gov (United States)

    Hübers, M; Pourhassan, M; Braun, W; Geisler, C; Müller, M J

    2017-09-01

    This study aims to determine associations between anthropometric traits, regional fat depots and insulin resistance in children, adolescents and adults to define new cut-offs of body mass index (BMI) or waist circumference (WC). Cross-sectional data were assessed in 433 children, adolescents and adults (aged: 6-60 years, BMI: 23.6 [21.0-27.7] kg m -2 ). Total adipose tissue (TAT), regional subcutaneous adipose tissue (SAT total , SAT trunk ) and visceral adipose tissue (VAT) were determined by whole-body magnetic resonance imaging, fat mass by air-displacement plethysmography. Insulin resistance was evaluated by homeostasis model assessment of insulin resistance (HOMA-IR). Bivariate as well as partial correlations and regression analyses were used. Cut-off values of BMI and WC related to regional fat depots and HOMA-IR were analysed by receiver operating characteristics curve. In adults, TAT, SAT total and SAT trunk increased linearly with increasing BMI and WC, whereas they followed a cubic function in children and adolescents with a steep increase at BMI and WC ≥1 standard deviation score and VAT at WC ≥2 standard deviation score. Sex differences were apparent in adults with women having higher masses of TAT and SAT and men having higher VAT. Using established BMI or WC cut-offs, correspondent masses of TAT, SAT total , SAT trunk and VAT increased from childhood to adulthood. In all age groups, there were positive associations between BMI, WC, SAT trunk , VAT and HOMA-IR. When compared with normative cut-offs of BMI or WC, HOMA-IR-derived cut-offs of regional fat depots were lower in all age groups. Associations between BMI, WC and regional fat depots varied between children, adolescents, young and older adults. When compared with BMI-derived and WC-derived values, an insulin resistance-derived cut-off corresponded to lower masses of regional fat depots. Thus, established BMI and WC cut-offs are not appropriate to assess metabolic disturbances associated

  9. Testing the role of meander cutoff in promoting gene flow across a riverine barrier in ground skinks (Scincella lateralis.

    Directory of Open Access Journals (Sweden)

    Nathan D Jackson

    Full Text Available Despite considerable attention, the long-term impact of rivers on species diversification remains uncertain. Meander loop cutoff (MLC is one river phenomenon that may compromise a river's diversifying effects by passively transferring organisms from one side of the river to the other. However, the ability of MLC to promote gene flow across rivers has not been demonstrated empirically. Here, we test several predictions of MLC-mediated gene flow in populations of North American ground skinks (Scincella lateralis separated by a well-established riverine barrier, the Mississippi River: 1 individuals collected from within meander cutoffs should be more closely related to individuals across the river than on the same side, 2 individuals within meander cutoffs should contain more immigrants than individuals away from meander cutoffs, 3 immigration rates estimated across the river should be highest in the direction of the cutoff event, and 4 the distribution of alleles native to one side of the river should be better predicted by the historical rather than current path of the river. To test these predictions we sampled 13 microsatellite loci and mitochondrial DNA from ground skinks collected near three ancient meander loops. These predictions were generally supported by genetic data, although support was stronger for mtDNA than for microsatellite data. Partial support for genetic divergence of samples within ancient meander loops also provides evidence for the MLC hypothesis. Although a role for MLC-mediated gene flow was supported here for ground skinks, the transient nature of river channels and morphologies may limit the long-term importance of MLC in stemming population divergence across major rivers.

  10. Validation of a cutoff for the Depression Scale of the Center for Epidemiologic Studies, Brief Version (CESD-7.

    Directory of Open Access Journals (Sweden)

    Aarón Salinas-Rodríguez

    2013-05-01

    Full Text Available Objective. To evaluate the Depression Scale of the Center for Epidemiologic Studies, Brief Version (CESD-7 psychometric properties in Mexican adult population, and validate a cutoff for classifying subjects according to the presence / absence of clinically significant depressive symptoms (CSDS. Materials and methods. Screening cross-sectional study with a subsample of 301 adult residents of the Morelos state in Mexico, originally interviewed for the National Survey of Health and Nutrition 2012. Sensitivity and specificity of the selected cutoff were estimated using as reference the diagnostic criteria of ICD-10 and DSM-IV. Results. The cutoff point estimated was CESD-7=9. Using the ICD-10 the sensitivity and specificity were 90.2 and 86%, and ROC was 88%. Using DSM-IV, the values were 80.4, 89.6, and 85%, respectively. Conclusions. The short version of the CESD-7 has good psychometric properties and can be used as a screening test to identify probable cases of subjects with clinically significant depressive symptoms.

  11. Practical use of visual medial temporal lobe atrophy cut-off scores in Alzheimer's disease: Validation in a large memory clinic population

    International Nuclear Information System (INIS)

    Claus, Jules J.; Holl, Dana C.; Roorda, Jelmen J.; Staekenborg, Salka S.; Schuur, Jacqueline; Koster, Pieter; Tielkes, Caroline E.M.; Scheltens, Philip

    2017-01-01

    To provide age-specific medial temporal lobe atrophy (MTA) cut-off scores for routine clinical practice as marker for Alzheimer's disease (AD). Patients with AD (n = 832, mean age 81.8 years) were compared with patients with subjective cognitive impairment (n = 333, mean age 71.8 years) in a large single-centre memory clinic. Mean of right and left MTA scores was determined with visual rating (Scheltens scale) using CT (0, no atrophy to 4, severe atrophy). Relationships between age and MTA scores were analysed with regression analysis. For various MTA cut-off scores, decade-specific sensitivity and specificity and area under the curve (AUC) values, computed with receiver operator characteristic curves, were determined. MTA strongly increased with age in both groups to a similar degree. Optimal MTA cut-off values for the age ranges <65, 65-74, 75-84 and ≥85 were: ≥1.0, ≥1.5, ≥ 2.0 and ≥2.0. Corresponding values of sensitivity and specificity were 83.3% and 86.4%; 73.7% and 84.6%; 73.7% and 76.2%; and 84.0% and 62.5%. From this large unique memory clinic cohort we suggest decade-specific MTA cut-off scores for clinical use. After age 85 years, however, the practical usefulness of the MTA cut-off is limited. (orig.)

  12. Revisiting the Phadia/EliA cut-off values for anticardiolipin and anti-β2-glycoprotein I antibodies: a systematic evaluation according to the guidelines.

    Science.gov (United States)

    Bor, M V; Jacobsen, I-L Søtang; Gram, J B; Sidelmann, J J

    2018-01-01

    Background Phadia/EliA fluorescence enzyme immunoassays are widely used automated assays for anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GPI) antibodies. To date, cut-off values for these assays have not been evaluated systematically and the evidence behind manufacturer's recommended cut-off values is not clear. Objective To determine Phadia/EliA cut-off values for antiphospholipid antibodies (aPL) according to the procedures suggested by guidelines. Methods A total of 266 blood donors (135 females and 131 males) were included. The pre-handling and analysis of the samples were performed according to the International Society on Thrombosis and Hemostasis (ISTH) guideline for solid phase aPL assays. Cut-off values and corresponding 90% confidence intervals (CI) for each antibody were established and outliers were handled according to the Clinical and Laboratory Standards Institute (CLSI) guideline for reference intervals. Samples from 377 consecutive patients, referred to our thrombophilia center with evidence of thrombosis or pregnancy morbidity were included for aPL testing. Results The in-house 99th (97.5th) percentile cut-off values were 11 (8.7), 12 (6.9) 8.5 (5.0) AU/mL for aβ2GPI IgG, IgM and IgA, and 21 (13) GPL-U/mL and 41 (25) MPL-U/mL for aCL IgG and IgM, respectively. The prevalence of positive results (%) defined by these cut-off values in patients with evidence of thrombosis or pregnancy morbidity was 9.5 (12.2), 1.6 (2.9), and 7.0 (9.9), and 0.8 (3.8) for aβ2GPI IgG, IgM, and aCL IgG and IgM respectively. The use of in-house 99th percentile cut-off values compared to the manufacturer suggested cut-off values resulted in 1 and 39 fewer samples for aβ2GPI and aCL to be classified as positive for aPL, respectively. Conclusions We present Phadia/EliA cut-off values with 90% CI for aPL determined systematically according to the ISTH and CLSI guidelines. These values are different from values previously determined, suggesting variation of a

  13. Plasma folic acid cutoff value, derived from its relationship with homocyst(e)ine

    NARCIS (Netherlands)

    Brouwer, D A; Welten, H T; Reijngoud, D J; van Doormaal, J J; Muskiet, F A

    We established the cutoff value for plasma folic acid, using plasma homocyst(e)ine as the functional marker. To do this, we investigated the relationship of the plasma folic acid of 103 apparently healthy adults with their fasting plasma homocyst(e)ine and with their plasma homocyst(e)ine 6 h after

  14. Using SSL-Bypass Concept to Eliminate Cutoff of Labs-Services during its Maintenance Period

    International Nuclear Information System (INIS)

    ElDib, A.A.

    2014-01-01

    This Design Concept of Interior Architecture concerned with Design Flexibility (George Fischer, Valve and Actuator Manual 977, Laboratories For The 21ST Century : Best Practices-2004) is designated for lab areas - specially those using radioactive materials - in need for constant feeding of service supplies without any interruption of the ongoing activities taking place in research laboratories. The paper also will discuss the implementation of sensors attached to the Automation of building Management which form a part of a control system network and surveillance and related to safety purpose measures to be considered for these types of research buildings. (NOTE:- It is important to mention that some types of research activities cannot tolerate the cutoff of services supply for long time, on the other hand some others DO NOT tolerate this cutoff at any time of the 24 hours in a given day/ or a period of days

  15. The assessment of anorexia in patients with cancer: cut-off values for the FAACT-A/CS and the VAS for appetite.

    Science.gov (United States)

    Blauwhoff-Buskermolen, S; Ruijgrok, C; Ostelo, R W; de Vet, H C W; Verheul, H M W; de van der Schueren, M A E; Langius, J A E

    2016-02-01

    Anorexia is a frequently observed symptom in patients with cancer and is associated with limited food intake and decreased quality of life. Diagnostic instruments such as the Anorexia/Cachexia Subscale (A/CS) of the Functional Assessment of Anorexia/Cachexia Therapy (FAACT) questionnaire and the visual analog scale (VAS) for appetite have been recommended in the assessment of anorexia, but validated cut-off values are lacking. This study aimed to obtain cut-off values of these instruments for the assessment of anorexia in patients with cancer. The FAACT-A/CS and the VAS for appetite were administered to patients with cancer before start of chemotherapy. As reference standard for anorexia, two external criteria were used: (1) a cut-off value of ≥2 on the anorexia symptom scale of the EORTC QLQ C-30 and (2) the question "Do you experience a decreased appetite?" (yes/no). ROC curves were used to examine the optimal cut-off values for the FAACT-A/CS and VAS. A total of 273 patients (58 % male; 64.0 ± 10.6 years) were included. The median score on the FAACT-A/CS was 38 (IQR 32-42) points and 77 (IQR 47-93) points on the VAS. Considering both external criteria, the optimal cut-off value for the FAACT-A/CS was ≤37 (sensitivity (se) 80 %, specificity (sp) 81 %, positive predictive value (PV(+)) 79 %, negative predictive value (PV(-)) 82 %) and for the VAS was ≤70 (se 76 %, sp 83 %, PV(+) 80 %, PV(-) 79 %). For the assessment of anorexia in patients with cancer, our study suggests cut-off values of ≤37 for the FAACT-A/CS and ≤70 for the VAS. Future studies should confirm our findings in other patient samples.

  16. Cut-Off Levels of Anti-Mullerian Hormone for The Prediction of Ovarian Response, In Vitro Fertilization Outcome and Ovarian Hyperstimulation Syndrome

    Directory of Open Access Journals (Sweden)

    Ali Salmassi

    2015-07-01

    Full Text Available Background: Evaluation of anti-mullerian hormone (AMH cut-off levels in assisted reproductive technology (ART as predictive factor for individualization of stimulation protocols and to avoid ovarian hyperstimulation syndrome (OHSS. Materials and Methods: In a retrospective study, 177 infertile patients were assessed for AMH in serum and follicular fluid (FF on the day of follicular puncture (FP, between 2012 and 2013 in Kiel, Germany. AMH levels and pregnancy rates were compared between low, moderate and high responders and cut-off levels of low and high responders. AMH cut-off levels in pathological cases were evaluated in analysis 1 (OHSS and in analysis 2 [polycystic ovarian syndrome, (PCOS] and compared in analysis 3 to normal endocrinological parameters. Results: AMH levels in FF were higher than in serum (P<0.001. AMH levels in serum and FF increased from low through moderate to high responders (P<0.001. Pregnancy rates were 14.7, 23.3 and 44.9% (P=0.009, respectively. AMH cut-off level for poor responders was 0.61 ng/ml in serum with a pregnancy rate of 13.8 and 37.1% for below and above of this level, respectively. For FF, it was 1.43 ng/ml. AMH levels in analysis 1 and 2 were significantly higher than in analysis 3 (P=0.001. AMH cut-off level for OHSS was 1.5 ng/ml in serum with OHSS rates of 80.8 and 19.2 % for above and below of the level, respectively. For FF, it was 2.7 ng/ml. PCOS patients had an AMH cut-off level of 3.9 ng/ml in serum and 6.8 ng/ml in FF, resulting in a PCOS rate of 100% above this level. Conclusion: AMH levels can help to assess ovarian response potential and guide ovarian stimulation while avoiding OHSS.

  17. Special nuclear materials cutoff exercise: Issues and lessons learned. Volume 1: Summary of exercise

    International Nuclear Information System (INIS)

    Libby, R.A.; Davis, C.; Segal, J.E.; Stanbro, W.D.

    1995-08-01

    In a September 1993 address to the United Nations General Assembly, President Clinton announced a new nonproliferation and export control policy that established a framework for US efforts to prevent the proliferation of weapons of mass destruction. The new policy proposed that the US undertake a comprehensive approach to the growing accumulation of fissile material. One of the key elements was for the US to support a special nuclear materials (SNM) multilateral convention prohibiting the production of highly enriched uranium (HEU) or plutonium for nuclear explosives purposes or outside of international safeguards. This policy is often referred to as the President's Cutoff Initiative or the Fissile Material Cutoff Treaty (FMCT). Because both the US Department of Energy (DOE) and foreign reprocessing facilities similar to PUREX will likely to be inspected under a FMCT, the DOE Office of Arms Control and Nonproliferation, Negotiations and Analysis Division (DOE/NN-41) tasked Pacific Northwest Laboratory (PNL) to perform an information gathering exercise, the PUREX Exercise, using the Plutonium-Uranium Extraction (PUREX) Plant located on the Hanford Site in Washington State. PUREX is a former production reactor fuel reprocessing plant currently undergoing a transition to a ''decontamination and decommissioning (D ampersand D) ready'' mode. The PUREX Exercise was conducted March 29--30, 1994, to examine aspects of the imposition of several possible cutoff regimes and to study verification of non-production of SNM for nuclear weapons purposes or outside of safeguards. A follow-up activity to further examine various additional verification regimes was held at Los Alamos National Laboratory (LANL) on May 10, 1994

  18. Sinus cut-off sign: A helpful sign in the CT diagnosis of diaphragmatic rupture associated with pleural effusion

    International Nuclear Information System (INIS)

    Kaya, Seyda Ors; Karabulut, Nevzat; Yuncu, Gokhan; Sevinc, Serpil; Kiroglu, Yilmaz

    2006-01-01

    The objective of our study was to describe the 'sinus cut-off' sign at CT in the diagnosis of diaphragmatic rupture in patients with blunt abdominal trauma complicated with pleural effusion, and evaluate its utility in an experimental model. Between January 2004 and March 2005, we observed an unusual interruption of costophrenic sinus at CT in three patients with blunt abdominal trauma accompanied with pleural effusion. This observation prompted us to evaluate the utility of this sign in an experimental model. Laparotomically, we created 2 cm diapragmatic lacerations at each hemidiaphragm in two rabbits and pushed up the abdominal viscera with omentum through the defect. To simulate hemothorax, we also injected 5-10 mL of diluted contrast material into the pleural space. Using a dual-slice helical CT scanner, limited thoracoabdominal CT examination was performed before and after injection of intrapleural contrast material. The images were analyzed for the presence of CT signs for diaphragmatic injury. The left posterior costophrenic sulcus was interrupted in all of the three patients with left pleural effusion. While it was associated with other findings of diaphragmatic injury, the 'sinus cut-off sign' was the sole finding in one patient. The sinus cut-off sign was observed on the CT scans of 100% of the rabbits with a left and right sided diaphragmatic rupture. The 'sinus cut-off sign' is useful and can increase the CT detection of acute diaphragmatic injury associated with pleural effusion

  19. Exploring optimum cut-off scores to screen for probable posttraumatic stress disorder within a sample of UK treatment-seeking veterans

    Science.gov (United States)

    Murphy, Dominic; Ross, Jana; Ashwick, Rachel; Armour, Cherie; Busuttil, Walter

    2017-01-01

    ABSTRACT Background: Previous research exploring the psychometric properties of the scores of measures of posttraumatic stress disorder (PTSD) suggests there is variation in their functioning depending on the target population. To date, there has been little study of these properties within UK veteran populations. Objective: This study aimed to determine optimally efficient cut-off values for the Impact of Event Scale-Revised (IES-R) and the PTSD Checklist for DSM-5 (PCL-5) that can be used to assess for differential diagnosis of presumptive PTSD. Methods: Data from a sample of 242 UK veterans assessed for mental health difficulties were analysed. The criterion-related validity of the PCL-5 and IES-R were evaluated against the Clinician-Administered PTSD Scale for DSM-5 (CAPS-5). Kappa statistics were used to assess the level of agreement between the DSM-IV and DSM-5 classification systems. Results: The optimal cut-off scores observed within this sample were 34 or above on the PCL-5 and 46 or above on the IES-R. The PCL-5 cut-off is similar to the previously reported values, but the IES-R cut-off identified in this study is higher than has previously been recommended. Overall, a moderate level of agreement was found between participants screened positive using the DSM-IV and DSM-5 classification systems of PTSD. Conclusions: Our findings suggest that the PCL-5 and IES-R can be used as brief measures within veteran populations presenting at secondary care to assess for PTSD. The use of a higher cut-off for the IES-R may be helpful for differentiating between veterans who present with PTSD and those who may have some sy`mptoms of PTSD but are sub-threshold for meeting a diagnosis. Further, the use of more accurate optimal cut-offs may aid clinicians to better monitor changes in PTSD symptoms during and after treatment. PMID:29435200

  20. Optimal cutoff values of WHO-HPQ presenteeism scores by ROC analysis for preventing mental sickness absence in Japanese prospective cohort.

    Directory of Open Access Journals (Sweden)

    Tomoko Suzuki

    Full Text Available Sickness absence due to mental disease in the workplace has become a global public health problem. Previous studies report that sickness presenteeism is associated with sickness absence. We aimed to determine optimal cutoff scores for presenteeism in the screening of the future absences due to mental disease.A prospective study of 2195 Japanese employees from all areas of Japan was conducted. Presenteeism and depression were measured by the validated Japanese version of the World Health Organization Health and Work Performance Questionnaire (WHO-HPQ and K6 scale, respectively. Absence due to mental disease across a 2-year follow-up was surveyed using medical certificates obtained for work absence. Socioeconomic status was measured via a self-administered questionnaire. Receiver operating curve (ROC analysis was used to determine optimal cutoff scores for absolute and relative presenteeism in relation to the area under the curve (AUC, sensitivity, and specificity.The AUC values for absolute and relative presenteeism were 0.708 (95% CI, 0.618-0.797 and 0.646 (95% CI, 0.546-0.746, respectively. Optimal cutoff scores of absolute and relative presenteeism were 40 and 0.8, respectively. With multivariate adjustment, cohort participants with our proposal cutoff scores for absolute and relative presenteeism were significantly more likely to be absent due to mental disease (OR = 4.85, 95% CI: 2.20-10.73 and OR = 5.37, 95% CI: 2.42-11.93, respectively. The inclusion or exclusion of depressive symptoms (K6≥13 at baseline in the multivariate adjustment did not influence the results.Our proposed optimal cutoff scores of absolute and relative presenteeism are 40 and 0.8, respectively. Participants who scored worse than the cutoff scores for presenteeism were significantly more likely to be absent in future because of mental disease. Our findings suggest that the utility of presenteeism in the screening of sickness absence due to mental disease would

  1. Exploring optimum cut-off scores to screen for probable posttraumatic stress disorder within a sample of UK treatment-seeking veterans.

    Science.gov (United States)

    Murphy, Dominic; Ross, Jana; Ashwick, Rachel; Armour, Cherie; Busuttil, Walter

    2017-01-01

    Background : Previous research exploring the psychometric properties of the scores of measures of posttraumatic stress disorder (PTSD) suggests there is variation in their functioning depending on the target population. To date, there has been little study of these properties within UK veteran populations. Objective : This study aimed to determine optimally efficient cut-off values for the Impact of Event Scale-Revised (IES-R) and the PTSD Checklist for DSM-5 (PCL-5) that can be used to assess for differential diagnosis of presumptive PTSD. Methods : Data from a sample of 242 UK veterans assessed for mental health difficulties were analysed. The criterion-related validity of the PCL-5 and IES-R were evaluated against the Clinician-Administered PTSD Scale for DSM-5 (CAPS-5). Kappa statistics were used to assess the level of agreement between the DSM-IV and DSM-5 classification systems. Results : The optimal cut-off scores observed within this sample were 34 or above on the PCL-5 and 46 or above on the IES-R. The PCL-5 cut-off is similar to the previously reported values, but the IES-R cut-off identified in this study is higher than has previously been recommended. Overall, a moderate level of agreement was found between participants screened positive using the DSM-IV and DSM-5 classification systems of PTSD. Conclusions : Our findings suggest that the PCL-5 and IES-R can be used as brief measures within veteran populations presenting at secondary care to assess for PTSD. The use of a higher cut-off for the IES-R may be helpful for differentiating between veterans who present with PTSD and those who may have some sy`mptoms of PTSD but are sub-threshold for meeting a diagnosis. Further, the use of more accurate optimal cut-offs may aid clinicians to better monitor changes in PTSD symptoms during and after treatment.

  2. Derivation and Cross-Validation of Cutoff Scores for Patients With Schizophrenia Spectrum Disorders on WAIS-IV Digit Span-Based Performance Validity Measures.

    Science.gov (United States)

    Glassmire, David M; Toofanian Ross, Parnian; Kinney, Dominique I; Nitch, Stephen R

    2016-06-01

    Two studies were conducted to identify and cross-validate cutoff scores on the Wechsler Adult Intelligence Scale-Fourth Edition Digit Span-based embedded performance validity (PV) measures for individuals with schizophrenia spectrum disorders. In Study 1, normative scores were identified on Digit Span-embedded PV measures among a sample of patients (n = 84) with schizophrenia spectrum diagnoses who had no known incentive to perform poorly and who put forth valid effort on external PV tests. Previously identified cutoff scores resulted in unacceptable false positive rates and lower cutoff scores were adopted to maintain specificity levels ≥90%. In Study 2, the revised cutoff scores were cross-validated within a sample of schizophrenia spectrum patients (n = 96) committed as incompetent to stand trial. Performance on Digit Span PV measures was significantly related to Full Scale IQ in both studies, indicating the need to consider the intellectual functioning of examinees with psychotic spectrum disorders when interpreting scores on Digit Span PV measures. © The Author(s) 2015.

  3. Microscopy of Stained Urethral Smear in Male Urethritis; Which Cutoff Should be Used?

    Science.gov (United States)

    Moi, Harald; Hartgill, Usha; Skullerud, Kristin Helene; Reponen, Elina J; Syvertsen, Line; Moghaddam, Amir

    2017-03-01

    The microscopical diagnosis of male urethritis was recently questioned by Rietmeijer and Mettenbrink, lowering the diagnostic criteria of the diagnosis to ≥2 polymorphonuclear leucocytes (PMNL) per high power field (HPF), and adopted by Centers for Disease Control and Prevention in their 2015 STD Treatment Guidelines. The European Non-Gonococcal Urethritis Guideline advocates a limit of ≥5 PMNL/HPF. To determine if syndromic treatment of urethritis should be considered with a cutoff value of ≥2 PMNL/HPF in urethral smear. The design was a cross-sectional study investigating the presence and degree of urethritis relative to specific infections in men attending an STI clinic as drop-in patients. The material included 2 cohorts: a retrospective study of 13,295 men and a prospective controlled study including 356 men. We observed a mean chlamydia prevalence of 2.3% in the 0-9 stratum, and a 12-fold higher prevalence (27.3%) in the strata above 9. Of the chlamydia cases, 89.8% were diagnosed in strata above 9. For Mycoplasma genitalium, the prevalence was 1.4% in the 0-9 stratum and 11.2% in the stratum ≥10, and 83.6% were diagnosed in strata above 9. For gonorrhea, a significant increase in the prevalence occurred between the 0-30 strata and >30 strata from 0.2% to 20.7%. The results of the prospective study were similar. Our data do not support lowering the cutoff to ≥2 PMNL/HPF. However, a standardization of urethral smear microscopy seems to be impossible. The cutoff value should discriminate between low and high prevalence of chlamydia, mycoplasma, and gonorrhea to include as many as possible with a specific infection in syndromic treatment, without overtreating those with few PMNL/HPF and high possibility of having nonspecific or no urethritis.

  4. Angiogenic Markers Predict Pregnancy Complications and Prolongation in Preeclampsia: Continuous Versus Cutoff Values.

    Science.gov (United States)

    Saleh, Langeza; Vergouwe, Yvonne; van den Meiracker, Anton H; Verdonk, Koen; Russcher, Henk; Bremer, Henk A; Versendaal, Hans J; Steegers, Eric A P; Danser, A H Jan; Visser, Willy

    2017-11-01

    To assess the incremental value of a single determination of the serum levels of sFlt-1 (soluble Fms-like tyrosine kinase 1) and PlGF (placental growth factor) or their ratio, without using cutoff values, for the prediction of maternal and fetal/neonatal complications and pregnancy prolongation, 620 women with suspected/confirmed preeclampsia, aged 18 to 48 years, were included in a prospective, multicenter, observational cohort study. Women had singleton pregnancies and a median pregnancy duration of 34 (range, 20-41) weeks. Complications occurred in 118 women and 248 fetuses. The median duration between admission and delivery was 12 days. To predict prolongation, PlGF showed the highest incremental value ( R 2 =0.72) on top of traditional predictors (gestational age at inclusion, diastolic blood pressure, proteinuria, creatinine, uric acid, alanine transaminase, lactate dehydrogenase, and platelets) compared with R 2 =0.53 for the traditional predictors only. sFlt-1 showed the highest value to discriminate women with and without maternal complications (C-index=0.83 versus 0.72 for the traditional predictors only), and the sFlt-1/PlGF ratio showed the highest value to discriminate fetal/neonatal complications (C-index=0.86 versus 0.78 for the traditional predictors only). Applying previously suggested cutoff values for the sFlt-1/PlGF ratio yielded lower incremental values than applying continuous values. In conclusion, sFlt-1 and PlGF are strong and independent predictors for days until delivery along with maternal and fetal/neonatal complications on top of the traditional criteria. Their use as continuous variables (instead of applying cutoff values for different gestational ages) should now be tested in a prospective manner, making use of an algorithm calculating the risk of an individual woman with suspected/confirmed preeclampsia to develop complications. © 2017 American Heart Association, Inc.

  5. Finite GUE Distribution with Cut-Off at a Shock

    Science.gov (United States)

    Ferrari, P. L.

    2018-03-01

    We consider the totally asymmetric simple exclusion process with initial conditions generating a shock. The fluctuations of particle positions are asymptotically governed by the randomness around the two characteristic lines joining at the shock. Unlike in previous papers, we describe the correlation in space-time without employing the mapping to the last passage percolation, which fails to exists already for the partially asymmetric model. We then consider a special case, where the asymptotic distribution is a cut-off of the distribution of the largest eigenvalue of a finite GUE matrix. Finally we discuss the strength of the probabilistic and physically motivated approach and compare it with the mathematical difficulties of a direct computation.

  6. Cut-off value of body fat in association with metabolic syndrome in Thai peri- and postmenopausal women.

    Science.gov (United States)

    Bintvihok, W; Chaikittisilpa, S; Panyakamlerd, K; Jaisamrarn, U; Taechakraichana, N

    2013-06-01

    Pathophysiologic changes during the menopause transition may contribute to the risk of metabolic syndrome (MetS). Body fat composition, particularly visceral fat, is highly associated with increased insulin resistance, abnormal carbohydrate metabolism and high blood pressure. We purposefully wished to determine the optimal cut-off values of body fat composition, including visceral fat, in order to predict MetS and to assess the prevalence of MetS in peri- and postmenopausal women. This cross-sectional study was conducted in a population-based, prospective cohort at the Menopause and Gynecology clinics, King Chulalongkorn Memorial Hospital. Body fat percentage and visceral fat rating were measured by a bioelectrical impedance analyzer (Tanita SC 330). MetS was diagnosed using the Harmonizing criteria of A Joint Interim Statement of IDF/NHLBI/AHA/WHF/IAS/IASO 2009. Receiver operating characteristic analyses were performed to determine the optimal cut-off values of body fat, visceral fat, waist circumference and body mass index to identify peri- and postmenopausal women at risk of MetS. Ninety-two perimenopausal and 446 postmenopausal women aged 40-60 years were recruited for the analyses. The optimal cut-off values for body fat percentage, visceral fat rating, waist circumference and body mass index for identifying women at risk of MetS were 34%, 7, 88 cm and 24 kg/m(2), respectively. The prevalence of MetS in this study was 27.9%. The optimal cut-off values to predict MetS of body fat percentage, visceral fat and waist circumference were established. Using the Harmonizing 2009 criteria, we found that approximately one out of four peri- and postmenopausal women in this study had MetS.

  7. A temperature-sensitive allele of a putative mRNA splicing helicase down-regulates many cell wall genes and causes radial swelling in Arabidopsis thaliana.

    Science.gov (United States)

    Howles, Paul A; Gebbie, Leigh K; Collings, David A; Varsani, Arvind; Broad, Ronan C; Ohms, Stephen; Birch, Rosemary J; Cork, Ann H; Arioli, Tony; Williamson, Richard E

    2016-05-01

    The putative RNA helicase encoded by the Arabidopsis gene At1g32490 is a homolog of the yeast splicing RNA helicases Prp2 and Prp22. We isolated a temperature-sensitive allele (rsw12) of the gene in a screen for root radial swelling mutants. Plants containing this allele grown at the restrictive temperature showed weak radial swelling, were stunted with reduced root elongation, and contained reduced levels of cellulose. The role of the protein was further explored by microarray analysis. By using both fold change cutoffs and a weighted gene coexpression network analysis (WGCNA) to investigate coexpression of genes, we found that the radial swelling phenotype was not linked to genes usually associated with primary cell wall biosynthesis. Instead, the mutation has strong effects on expression of secondary cell wall related genes. Many genes potentially associated with secondary walls were present in the most significant WGCNA module, as were genes coding for arabinogalactans and proteins with GPI anchors. The proportion of up-regulated genes that possess introns in rsw12 was above that expected if splicing was unrelated to the activity of the RNA helicase, suggesting that the helicase does indeed play a role in splicing in Arabidopsis. The phenotype may be due to a change in the expression of one or more genes coding for cell wall proteins.

  8. Problems in future negotiations for a treaty on the cut-off of fissile material for nuclear weapons

    International Nuclear Information System (INIS)

    Schaper, A.

    1999-01-01

    A treaty to end the production of fissile material for nuclear weapons, the so-called cutoff, is one of the most important next steps on the disarmament agenda.' But meanwhile, the Conference on Disarmament (CD) is deadlocked, and confidence in negotiations taking place in the near future is replaced by bewilderment at the inaction. The underlying conflict of the Comprehensive Test Ban Treaty (CTBT) negotiations can be summarized as nuclear disarmament versus nuclear nonproliferation. The same conflict is now blocking progress with negotiations in the CD on the Fissile Material Cut-off Treaty (FMCT). Nevertheless, the cut-off would be the major policy driver to insert transparency and irreversibility into the disarmament process,' and we need to harness all our efforts to overcome the current difficulties. The CTBT can be regarded as a tool to cap the qualitative nuclear arms race, for example to hinder the future development of qualitatively new nuclear explosives, and an FMCT can be seen as its quantitative counterpart, capping the amount of material available for new nuclear weapons. The complex questions involve political, technical, legal, and economic aspects and constitute a challenge for diplomats and decision makers

  9. Refining Game Addiction Questionnairs: Evidence for a natural cut-off point?

    OpenAIRE

    Nielsen, Rune Kristian

    2013-01-01

    This paper presents data from a pilot study, which was designed to illuminate critical flaws in the currently used instruments used to measure the prevalence of ‘computer game addiction’. The study found that the prevalence rate could be set anywhere between 23% and 0,6% depending on how the data set is scored. Thus demonstrating how an arbitrarily set of cut-off point in prevalence studies can yield wildly varying prevalence rates. The data further show that making implicit assumptions about...

  10. Tuberculin skin testing in patients with HIV infection: limited benefit of reduced cutoff values

    NARCIS (Netherlands)

    Cobelens, Frank G.; Egwaga, Saidi M.; van Ginkel, Tessa; Muwinge, Hemed; Matee, Mecky I.; Borgdorff, Martien W.

    2006-01-01

    BACKGROUND: When determining eligibility for isoniazid preventive therapy of human immunodeficiency virus (HIV)-infected patients, the cutoff value of the tuberculin skin test (TST) is often reduced from an induration of 10 mm in diameter to one of 5 mm in diameter to compensate for loss of

  11. Determinants of self-reported smoking and misclassification during pregnancy, and analysis of optimal cut-off points for urinary cotinine: a cross-sectional study.

    Science.gov (United States)

    Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran

    2013-01-24

    To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Prevalence of smoking during pregnancy in Spain remains high. UC is a reliable biomarker for classifying

  12. Determinants of self-reported smoking and misclassification during pregnancy, and analysis of optimal cut-off points for urinary cotinine: a cross-sectional study

    Science.gov (United States)

    Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran

    2013-01-01

    Objectives To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. Design We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. Participants At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Results Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Conclusions Prevalence of smoking during pregnancy in

  13. Cell Wall Remodeling Enzymes Modulate Fungal Cell Wall Elasticity and Osmotic Stress Resistance.

    Science.gov (United States)

    Ene, Iuliana V; Walker, Louise A; Schiavone, Marion; Lee, Keunsook K; Martin-Yken, Hélène; Dague, Etienne; Gow, Neil A R; Munro, Carol A; Brown, Alistair J P

    2015-07-28

    The fungal cell wall confers cell morphology and protection against environmental insults. For fungal pathogens, the cell wall is a key immunological modulator and an ideal therapeutic target. Yeast cell walls possess an inner matrix of interlinked β-glucan and chitin that is thought to provide tensile strength and rigidity. Yeast cells remodel their walls over time in response to environmental change, a process controlled by evolutionarily conserved stress (Hog1) and cell integrity (Mkc1, Cek1) signaling pathways. These mitogen-activated protein kinase (MAPK) pathways modulate cell wall gene expression, leading to the construction of a new, modified cell wall. We show that the cell wall is not rigid but elastic, displaying rapid structural realignments that impact survival following osmotic shock. Lactate-grown Candida albicans cells are more resistant to hyperosmotic shock than glucose-grown cells. We show that this elevated resistance is not dependent on Hog1 or Mkc1 signaling and that most cell death occurs within 10 min of osmotic shock. Sudden decreases in cell volume drive rapid increases in cell wall thickness. The elevated stress resistance of lactate-grown cells correlates with reduced cell wall elasticity, reflected in slower changes in cell volume following hyperosmotic shock. The cell wall elasticity of lactate-grown cells is increased by a triple mutation that inactivates the Crh family of cell wall cross-linking enzymes, leading to increased sensitivity to hyperosmotic shock. Overexpressing Crh family members in glucose-grown cells reduces cell wall elasticity, providing partial protection against hyperosmotic shock. These changes correlate with structural realignment of the cell wall and with the ability of cells to withstand osmotic shock. The C. albicans cell wall is the first line of defense against external insults, the site of immune recognition by the host, and an attractive target for antifungal therapy. Its tensile strength is conferred by

  14. Solar Walls in tsbi3

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne

    tsbi3 is a user-friendly and flexible computer program, which provides support to the design team in the analysis of the indoor climate and the energy performance of buildings. The solar wall module gives tsbi3 the capability of simulating solar walls and their interaction with the building....... This version, C, of tsbi3 is capable of simulating five types of solar walls say: mass-walls, Trombe-walls, double Trombe-walls, internally ventilated walls and solar walls for preheating ventilation air. The user's guide gives a description of the capabilities and how to simulate solar walls in tsbi3....

  15. 76 FR 33161 - Installation and Use of Engine Cut-off Switches on Recreational Vessels

    Science.gov (United States)

    2011-06-08

    ... ``Proposed Rule'' and insert ``USCG-2009-0206'' in the ``Keyword'' box. Click ``Search,'' then click on the... ``read comments'' box, which will then become highlighted in blue. In the ``Keyword'' box, insert ``USCG... add definitions that describe the terms ``engine cut-off switch link,'' ``engine cut- off switch...

  16. Addenbrooke's Cognitive Examination and Individual Domain Cut-Off Scores for Discriminating between Different Cognitive Subtypes of Parkinson's Disease.

    Science.gov (United States)

    Berankova, Dagmar; Janousova, Eva; Mrackova, Martina; Eliasova, Ilona; Kostalova, Milena; Skutilova, Svetlana; Rektorova, Irena

    2015-01-01

    Objective. The main aim of this study was to verify the sensitivity and specificity of Addenbrooke's Cognitive Examination-Revised (ACE-R) in discriminating between Parkinson's disease (PD) with normal cognition (PD-NC) and PD with mild cognitive impairment (PD-MCI) and between PD-MCI and PD with dementia (PD-D). We also evaluated how ACE-R correlates with neuropsychological cognitive tests in PD. Methods. We examined three age-matched groups of PD patients diagnosed according to the Movement Disorder Society Task Force criteria: PD-NC, PD-MCI, and PD-D. ROC analysis was used to establish specific cut-off scores of ACE-R and its domains. Correlation analyses were performed between ACE-R and its subtests with relevant neuropsychological tests. Results. Statistically significant differences between groups were demonstrated in global ACE-R scores and subscores, except in the language domain. ACE-R cut-off score of 88.5 points discriminated best between PD-MCI and PD-NC (sensitivity 0.68, specificity 0.91); ACE-R of 82.5 points distinguished best between PD-MCI and PD-D (sensitivity 0.70, specificity 0.73). The verbal fluency domain of ACE-R demonstrated the best discrimination between PD-NC and PD-MCI (cut-off score 11.5; sensitivity 0.70, specificity 0.73) while the orientation/attention subscore was best between PD-MCI and PD-D (cut-off score 15.5; sensitivity 0.90, specificity 0.97). ACE-R scores except for ACE-R language correlated with specific cognitive tests of interest.

  17. Finite element limit loads for non-idealized through-wall cracks in thick-walled pipe

    International Nuclear Information System (INIS)

    Shim, Do-Jun; Han, Tae-Song; Huh, Nam-Su

    2013-01-01

    Highlights: • The lower bound bulging factor of thin-walled pipe can be used for thick-walled pipe. • The limit loads are proposed for thick-walled, transition through-wall cracked pipe. • The correction factors are proposed for estimating limit loads of transition cracks. • The limit loads of short transition cracks are similar to those of idealized cracks. - Abstract: The present paper provides plastic limit loads for non-idealized through-wall cracks in thick-walled pipe. These solutions are based on detailed 3-dimensional finite element (FE) analyses which can be used for structural integrity assessment of nuclear piping. To cover a practical range of interest, the geometric variables and loading conditions affecting the plastic limit loads of thick-walled pipe with non-idealized through-wall cracks were systematically varied. In terms of crack orientation, both circumferential and axial through-wall cracks were considered. As for loading conditions, axial tension, global bending, and internal pressure were considered for circumferential cracks, whereas only internal pressure was considered for axial cracks. Furthermore, the values of geometric factor representing shape characteristics of non-idealized through-wall cracks were also systematically varied. In order to provide confidence in the present FE analyses results, plastic limit loads of un-cracked, thick-walled pipe resulting from the present FE analyses were compared with the theoretical solutions. Finally, correction factors to the idealized through-wall crack solutions were developed to determine the plastic limit loads of non-idealized through-wall cracks in thick-walled pipe

  18. Evaluation of an Optimal Cut-Off Point for the Ki-67 Index as a Prognostic Factor in Primary Breast Cancer: A Retrospective Study.

    Directory of Open Access Journals (Sweden)

    Rumiko Tashima

    Full Text Available The Ki-67 index is an important biomarker for indicating the proliferation of cancer cells and is considered to be an effective prognostic factor for breast cancer. However, a standard cut-off point for the Ki-67 index has not yet been established. Therefore, the aim of this retrospective study was to determine an optimal cut-off point in order to establish it as a more accurate prognostic factor. Immunohistochemical analysis of the Ki-67 index was performed on 4329 patients with primary breast cancer from August 1987 to March 2012. Out of this sample, there were 3186 consecutive cases from September 1997 with simultaneous evaluations of ER, PgR and HER2 status. Cox's proportional hazard model was used to perform univariate and multivariate analyses of the factors related to OS. The hazard ratios (HR and the p values were then compared to determine the optimal cut-off point for the Ki-67 index. The median Ki-67 index value was 20.5% (mean value 26.2%. The univariate analysis revealed that there was a statistically significant negative correlation with DFS and OS and the multivariate analysis revealed that the Ki-67 index value was a significant factor for DFS and OS. The top seven cut-off points were then carefully chosen based on the results of the univariate analysis using the lowest p-values and the highest HR as the main selection criteria. The multivariate analysis of the factors for OS showed that the cut-off point of 20% had the highest HR in all of the cases. However, the cutoff point of 20% was only a significant factor for OS in the Luminal/HER2- subtype. There was no correlation between the Ki-67 index value and OS in any of the other subtypes. These data indicate that the optimal cut-off point of 20% is the most effective prognostic factor for Luminal/HER2- breast cancer.

  19. Signatures of Synchrotron: Low-cutoff X-ray emission and the hard X-ray spectrum of Cas A

    Science.gov (United States)

    Stage, Michael D.; Fedor, Emily Elizabeth; Martina-Hood, Hyourin

    2018-06-01

    In soft X-rays, bright, young Galactic remnants (Cas A, Kepler, Tycho, etc.) present thermal line emission and bremsstrahlung from ejecta, and synchrotron radiation from the shocks. Their hard X-ray spectra tend to be dominated by power-law sources. However, it can be non-trivial to discriminate between contributions from processes such as synchrotron and bremsstrahlung from nonthermally accelerated electrons, even though the energies of the electrons producing this radiation may be very different. Spatially-resolved spectroscopic analysis of 0.5-10 keV observations with, e.g., Chandracan provide leverage in identifying the processes and their locations. Previously, Stage & Allen (2006), Allen & Stage (2007) and Stage & Allen (2011) identified regions characterized by high-cutoff synchrotron radiation. Extrapolating synchrotron model fits to the emission in the Chandra band, they estimated the synchrotron contribution to the hard X-ray spectrum at about one-third the observed flux, fitting the balance with nonthermal bremsstrahlung emission produced by nonthermal electrons in the ejecta. Although it is unlikely this analysis missed regions of the highest-cutoff synchrotron emission, which supplies the bulk of the synchrotron above 15 keV, it may have missed regions of lower-cutoff emission, especially if they are near bright ejecta and the reverse shock. These regions cannot explain the emission at the highest energies (~50 keV), but may make significant contributions to the hard spectrum at lower energies (~10 keV). Using the technique described in Fedor, Martina-Hood & Stage (this meeting), we revisit the analysis to include regions that may be dominated by low-cutoff synchrotron, located in the interior of the remnant, and/or correlated with the reverse shock. Identifying X-ray emission from accelerated electrons associated with the reverse-shock would have important implications for synchrotron and non-thermal bremsstrahlung radiation above the 10 keV.

  20. Adiposity cut-off points for cardiovascular disease and diabetes risk in the Portuguese population: The PORMETS study

    Science.gov (United States)

    Severo, Milton; Santos, Ana Cristina

    2018-01-01

    Objectives The contribution of adiposity to cardiovascular and diabetes risk justifies the inclusion of an adiposity measure, usually waist circumference, in the definition of metabolic syndrome. However, waist circumference thresholds differ across populations. Our aim was to assess which adiposity measure performs the best in identifying the metabolic syndrome in a sample of Portuguese participants and to estimate cut-off values for these measures. Methods Data were obtained from a cross-sectional study (PORMETS study) conducted in Portugal between 2007 and 2009. A representative sample of non-institutionalized adults, comprising 3,956 participants, aged 18 years and older, was evaluated. A structured questionnaire was administered, collecting information on personal medical history, socio-demographics and behavioral characteristics. Anthropometrics, blood pressure and venous blood samples were also obtained. Metabolic syndrome was defined according to the Joint Interim Statement of the International Diabetes Federation Task Force on Epidemiology recommended criteria. Elevated cardiometabolic risk was considered when two or more of the four criteria of metabolic syndrome were present, excluding the waist circumference component. A receiver operating characteristic curve was used to estimate cut-off points. Results This study found that waist-to-height ratio, waist circumference and body adiposity index performed better than other adiposity measures, such as body mass index. The estimated cut-off points for waist-to-height ratio, waist circumference and body adiposity index in women and men were 0.564 / 89 cm / 27.4 and 0.571 / 93.5 cm / 25.5, respectively. Conclusion As waist circumference is currently used as the adiposity measure in the definition of metabolic syndrome and as no relevant differences were observed between this measure and waist-to-height ratio, it is likely that no modification to the metabolic syndrome definition needs to be proposed. Moreover

  1. Appropriate body mass index and waist circumference cutoff for overweight and central obesity among adults in Cambodia.

    Directory of Open Access Journals (Sweden)

    Yom An

    Full Text Available BACKGROUND: Body mass index (BMI and waist circumference (WC are used in risk assessment for the development of non-communicable diseases (NCDs worldwide. Within a Cambodian population, this study aimed to identify an appropriate BMI and WC cutoff to capture those individuals that are overweight and have an elevated risk of vascular disease. METHODOLOGY/PRINCIPAL FINDINGS: We used nationally representative cross-sectional data from the STEP survey conducted by the Department of Preventive Medicine, Ministry of Health, Cambodia in 2010. In total, 5,015 subjects between age 25 and 64 years were included in the analyses. Chi-square, Fisher's Exact test and Student t-test, and multiple logistic regression were performed. Of total, 35.6% (n = 1,786 were men, and 64.4% (n = 3,229 were women. Mean age was 43.0 years (SD = 11.2 years and 43.6 years (SD = 10.9 years for men and women, respectively. Significant association of subjects with hypertension and hypercholesterolemia was found in those with BMI ≥ 23.0 kg/m(2 and with WC >80.0 cm in both sexes. The Area Under the Curve (AUC from Receiver Operating Characteristic curves was significantly greater in both sexes (all p-values <0.001 when BMI of 23.0 kg/m(2 was used as the cutoff point for overweight compared to that using WHO BMI classification for overweight (BMI ≥ 25.0 kg/m(2 for detecting the three cardiovascular risk factors. Similarly, AUC was also significantly higher in men (p-value <0.001 when using WC of 80.0 cm as the cutoff point for central obesity compared to that recommended by WHO (WC ≥ 94.0 cm in men. CONCLUSION: Lower cutoffs for BMI and WC should be used to identify of risks of hypertension, diabetes, and hypercholesterolemia for Cambodian aged between 25 and 64 years.

  2. Cut-Off Value for Pain Sensitivity Questionnaire in Predicting Surgical Success in Patients with Lumbar Disc Herniation.

    Directory of Open Access Journals (Sweden)

    Parisa Azimi

    Full Text Available Various factors related to predict surgical success were studied; however, a standard cut-off point for the Pain Sensitivity Questionnaire (PSQ measure has not yet been established for a favorable surgical outcome for lumbar disc herniation (LDH. This study was to find the optimal cut-off point on the PSQ to distinguish surgical success in patients with LDH. A total of 154 patients with LDH consecutively referred to our clinic were enrolled into this prospective study between February 2011 and January 2014. All participants completed the PSQ. Patients completed the Oswestry Disability Index (ODI score before surgery, and at 2 years after surgery. Surgical success was defined as a 13-point improvement from the baseline ODI scores. The cut-off value for PSQ was determined by the receiver-operating characteristic curve (ROC. The mean age of patients was 49.3±9.6 years, and there were 80 women. The mean time for follow-up assessment was 31±5 months (range 24-35. Post-surgical success was 79.9% (n = 123 at 2 years follow up. The mean score for the total PSQ, PSQ-minor, and PSQ-moderate were 6.0 (SD = 1.6, 5.4 (SD = 1.9 and 6.5 (SD = 1.7, respectively. Total PSQ score was also significantly correlated with the total scores of the ODI. The optimal total PSQ cut-off point was determined as > 5.2 to predict surgical success in LDH patients, with 80.0% sensitivity and 75.6% specificity (AUC-0.814, 95% CI 0.703-0.926. This study showed that the PSQ could be considered a parameter for predicting surgical success in patients with LDH, and can be useful in clinical practice.

  3. Physical and cut-off effects of heavy sea quarks

    CERN Document Server

    Knechtli, Francesco; Bruno, Mattia; Finkenrath, Jacob; Leder, Björn; Marinkovic, Marina; Sommer, Rainer

    2014-01-01

    We simulate a theory with two dynamical O($a$) improved Wilson quarks whose mass $M$ ranges from a factor eight up to a factor two below the charm quark mass and at three values of the lattice spacing ranging from 0.066 to 0.034 fm. This theory is a prototype to study the decoupling of heavy quarks. We measure the mass and cut-off dependence of ratios of gluonic observables defined from the Wilson flow or the static potential. The size of the 1/$M$ corrections can be determined and disentangled from the lattice artifacts. The difference with the pure gauge theory is at the percent level when two quarks with a mass of the charm quark are present.

  4. The cut-off values of anthropometric variables for predicting mild cognitive impairment in Malaysian older adults: a large population based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Won H

    2017-02-01

    Full Text Available Huiloo Won,1 Zahara Abdul Manaf,2 Arimi Fitri Mat Ludin,3 Mohd Azahadi Omar,4 Rosdinom Razali,5 Suzana Shahar2 1Nutrition Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 2Dietetics Program, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 3Biomedical Science Program, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, 4Centre for Burden of Disease Research, Institute for Public Health, Ministry of Health Malaysia, 5Department of Psychiatry, Faculty of Medicine, Hospital Canselor Tuanku Muhriz, University Kebangsaan Malaysia, Kuala Lumpur, Malaysia Purpose: Older adults are at risk of mild cognitive impairment (MCI, and simple anthropometric measurements can be used to screen for this condition. Thus, the aim of this study was to explore the cut-off values of body mass index (BMI and waist circumference (WC for predicting the risk of MCI in older Malaysian adults.Methods: A total of 2,240 Malaysian older adults aged ≥60 years were recruited using multistage random sampling in a population based cross-sectional study. Receiver operating characteristic (ROC curve was used to determine the cut-off values of BMI and WC with optimum sensitivity and specificity for the detection of MCI. Age, gender, years of education, smoking habit, alcohol consumption, depression, and medical conditions were used as confounding factors in this analysis.Results: A BMI cut-off value of 26 kg/m2 (area under the receiver operating characteristic curve [AUC] 0.725; sensitivity 90.5%; specificity 38.8% was appropriate in identifying the risk of getting MCI in both men and women. The optimum WC cut-offs for likelihood of MCI were 90 cm (AUC 0.745; sensitivity 78.0%; specificity 59.8% for men and 82 cm (AUC 0.714; sensitivity 84.3%; specificity 49.7% for women. The optimum calf circumference (CC cut-off values for identifying MCI were 29 cm (AUC 0.731; sensitivity 72.6%; specificity

  5. Ambiguous walls

    DEFF Research Database (Denmark)

    Mody, Astrid

    2012-01-01

    The introduction of Light Emitting Diodes (LEDs) in the built environment has encouraged myriad applications, often embedded in surfaces as an integrated part of the architecture. Thus the wall as responsive luminous skin is becoming, if not common, at least familiar. Taking into account how wall...

  6. Attenuation bands and cut-off frequencies for ELF electromagnetic waves

    International Nuclear Information System (INIS)

    Rauch, J.L.; Lefeuvre, F.; Cerisier, J.C.; Berthelier, J.J.; Boud'ko, N.; Michailova, G.; Kapustina, O.

    1985-01-01

    The propagation characteristic of ELF (10 Hz - 1500 Hz) electromagnetic waves observed on ARCAD 3, in three different zones: low L value (L 6). Unambiguous determinations of the wave normal directions are obtained from the interpretations of the measurements of four (3 magnetic, 1 electric) wave field components. The technique that is used, is based on the Means method in the cases of highly polarized waves and on the Storey and Lefeuvre WDF method in the other cases. A particular emphasis is put on the propagation characteristics of the waves, in a multiple ion plasma, and on the cut-off frequencies which appear at and below the local proton gyrofrequency

  7. Putative Dementia Cases Fluctuate as a Function of Mini-Mental State Examination Cut-Off Points.

    Science.gov (United States)

    Rosa, Ilka M; Henriques, Ana G; Wiltfang, Jens; da Cruz E Silva, Odete A B

    2018-01-01

    As the population ages, there is a growing need to quickly and accurately identify putative dementia cases. Many cognitive tests are available; among those commonly used are the Cognitive Dementia Rating (CDR) and the Mini-Mental Status Examination (MMSE). The aim of this work was to compare the validity and reliability of these cognitive tests in a primary care based cohort (pcb-Cohort). The MMSE and the CDR were applied to 568 volunteers in the pcb-Cohort. Distinct cut-off points for the MMSE were considered, namely MMSE 27, MMSE 24, and MMSE PT (adapted for the Portuguese population). The MMSE 27 identified the greatest number of putative dementia cases, and, as determined by the ROC curve, it was the most sensitive and specific of the MMSE cut-offs considered. Putative predictive or risk factors identified included age, literacy, depression, and diabetes mellitus (DM). DM has previously been indicated as a risk factor for dementia and Alzheimer's disease. Comparatively, the MMSE 27 cut-off has the greatest sensibility (94.9%) and specificity (66.3%) when compared to MMSE PT and MMSE 24. Upon comparing MMSE and CDR scores, the latter identified a further 146 putative dementia cases, thus permitting one to propose that in an ideal situation, both tests should be employed. This increases the likelihood of identifying putative dementia cases for subsequent follow up work, thus these cognitive tests represent important tools in patient care. Further, this is a significant study for Portuguese populations, where few of these studies have been carried out.

  8. Estimation of Cutoff Values of Cotinine in Urine and Saliva for Pregnant Women in Poland

    Directory of Open Access Journals (Sweden)

    Joanna Stragierowicz

    2013-01-01

    Full Text Available Setting appropriate cutoff values and the use of a highly sensitive analytical method allow for correct classification of the smoking status. Urine-saliva pairs samples of pregnant women in the second and third trimester, and saliva only in the first trimester were collected. Offline SPE and LC-ESI-MS/MS method was developed in the broad concentration range (saliva 0.4–1000 ng/mL, urine 0.8–4000 ng/mL. The mean recoveries were 3.7±7.6% for urine and 99.1±2.6% for saliva. LOD for saliva was 0.12 ng/mL and for urine 0.05 ng/mL; LOQ was 0.4 ng/mL and 0.8 ng/mL, respectively. Intraday and interday precision equaled, respectively, 1.2% and 3.4% for urine, and 2.3% and 6.4% for saliva. There was a strong correlation between salivary cotinine and the uncorrected cotinine concentration in urine in the second and third trimesters of pregnancy. The cutoff values were established for saliva 12.9 ng/mL and urine 42.3 ng/mL or 53.1 μg/g creatinine with the ROC curve analysis. The developed analytical method was successfully applied to quantify cotinine, and a significant correlation between the urinary and salivary cotinine levels was found. The presented cut-off values for salivary and urinary cotinine ensure a categorization of the smoking status among pregnant women that is more accurate than self-reporting.

  9. Nonmassive acute pulmonary embolism: evaluation of the impact of pulmonary arterial wall distensibility on the assessment of the CT obstruction score.

    Science.gov (United States)

    Bigot, Julien; Rémy-Jardin, Martine; Duhamel, Alain; Gorgos, Andréi-Bogdan; Faivre, Jean-Baptiste; Rémy, Jacques

    2010-02-01

    To evaluate the impact of pulmonary arterial wall distensibility on the assessment of a computed tomography (CT) score in patients with nonmassive pulmonary embolism (PE) (ie, Mastora score). The arterial wall distensibility of five central pulmonary arteries (pulmonary artery trunk, right and left main pulmonary arteries, right and left interlobar pulmonary arteries) was studied on ECG-gated CT angiographic studies of the chest in 15 patients with no pulmonary arterial hypertension (group 1; mean pulmonary artery pressure: 17.2 mm Hg) and 9 patients with nonmassive PE (group 2), using 2D reconstructions at every 10% of the R-R interval. The systolic and diastolic reconstruction time windows of the examined arteries were identical in the 2 groups, obtained at 20% and 80% of the R-R interval, respectively. No statistically significant difference was observed between the mean values of the pulmonary arterial wall distensibility between the 2 groups, varying between 20.5% and 24% in group 1 and between 23.3% and 25.9% in group 2. The coefficients of variation of the average arterial surfaces were found to vary between 4.30% and 6.50% in group 1 and 4.2% and 8.4% in group 2. Except the pulmonary artery trunk in group 2, all the intraclass correlation coefficients were around 0.8 or greater than 0.8, that is the cutoff for good homogeneity of measurements. The pulmonary arterial wall systolic-diastolic distensibility does not interfere with the assessment of a CT obstruction score in the setting of nonmassive PE.

  10. Practical use of visual medial temporal lobe atrophy cut-off scores in Alzheimer's disease: Validation in a large memory clinic population

    Energy Technology Data Exchange (ETDEWEB)

    Claus, Jules J.; Holl, Dana C.; Roorda, Jelmen J. [Tergooi Hospital, Department of Neurology, Blaricum (Netherlands); Staekenborg, Salka S. [Tergooi Hospital, Department of Neurology, Blaricum (Netherlands); VU University Medical Center, Department of Neurology, Alzheimer Center, Amsterdam (Netherlands); Schuur, Jacqueline [Tergooi Hospital, Department of Geriatrics, Blaricum (Netherlands); Koster, Pieter [Tergooi Hospital, Department of Radiology, Blaricum (Netherlands); Tielkes, Caroline E.M. [Tergooi Hospital, Department of Medical Psychology, Blaricum (Netherlands); Scheltens, Philip [VU University Medical Center, Department of Neurology, Alzheimer Center, Amsterdam (Netherlands)

    2017-08-15

    To provide age-specific medial temporal lobe atrophy (MTA) cut-off scores for routine clinical practice as marker for Alzheimer's disease (AD). Patients with AD (n = 832, mean age 81.8 years) were compared with patients with subjective cognitive impairment (n = 333, mean age 71.8 years) in a large single-centre memory clinic. Mean of right and left MTA scores was determined with visual rating (Scheltens scale) using CT (0, no atrophy to 4, severe atrophy). Relationships between age and MTA scores were analysed with regression analysis. For various MTA cut-off scores, decade-specific sensitivity and specificity and area under the curve (AUC) values, computed with receiver operator characteristic curves, were determined. MTA strongly increased with age in both groups to a similar degree. Optimal MTA cut-off values for the age ranges <65, 65-74, 75-84 and ≥85 were: ≥1.0, ≥1.5, ≥ 2.0 and ≥2.0. Corresponding values of sensitivity and specificity were 83.3% and 86.4%; 73.7% and 84.6%; 73.7% and 76.2%; and 84.0% and 62.5%. From this large unique memory clinic cohort we suggest decade-specific MTA cut-off scores for clinical use. After age 85 years, however, the practical usefulness of the MTA cut-off is limited. (orig.)

  11. Insulin resistance in obese children and adolescents: HOMA-IR cut-off levels in the prepubertal and pubertal periods.

    Science.gov (United States)

    Kurtoğlu, Selim; Hatipoğlu, Nihal; Mazıcıoğlu, Mümtaz; Kendirici, Mustafa; Keskin, Mehmet; Kondolot, Meda

    2010-01-01

    Childhood obesity is associated with an increased risk for insulin resistance. The underlying mechanism for the physiological increase in insulin levels in puberty is not clearly understood. The aim of the present study was to determine the cut-off values for homeostasis model assessment for insulin resistance (HOMA-IR) in obese children and adolescents according to gender and pubertal status. Two hundred and eight obese children and adolescents (141 girls, 127 boys) aged between 5 and 18 years were included in the study. The children were divided into prepubertal and pubertal groups. A standard oral glucose tolerance test (OGTT) was carried out in all children. A total insulin level exceeding 300 μU/mL in the blood samples, collected during the test period, was taken as the insulin resistance criterion. Cut-off values for HOMA-IR were calculated by receiver operating characteristic (ROC) analysis. In the prepubertal period, the rate of insulin resistance was found to be 37% in boys and 27.8% in girls,while in the pubertal period, this rate was 61.7% in boys and 66.7% in girls. HOMA-IR cut-off values for insulin resistance in the prepubertal period were calculated to be 2.67 (sensitivity 88.2%, specificity 65.5%) in boys and 2.22 (sensitivity 100%, specificity 42.3%) in girls, and in the pubertal period, they were 5.22 (sensitivity 56%, specificity 93.3%) in boys and 3.82 (sensitivity 77.1%, specificity 71.4%) in girls. Since gender, obesity and pubertal status are factors affecting insulin resistance, cut-off values which depend on gender and pubertal status, should be used in evaluation of insulin resistance.

  12. Flocking of the Motsch-Tadmor Model with a Cut-Off Interaction Function

    Science.gov (United States)

    Jin, Chunyin

    2018-04-01

    In this paper, we study the flocking behavior of the Motsch-Tadmor model with a cut-off interaction function. Our analysis shows that connectedness is important for flocking of this kind of model. Fortunately, we get a sufficient condition imposed only on the model parameters and initial data to guarantee the connectedness of the neighbor graph associated with the system. Then we present a theoretical analysis for flocking, and show that the system achieves consensus at an exponential rate.

  13. The Potential of Established Fitness Cut-off Points for Monitoring Women with Fibromyalgia: The al-Ándalus Project.

    Science.gov (United States)

    Castro-Piñero, José; Aparicio, Virginia A; Estévez-López, Fernando; Álvarez-Gallardo, Inmaculada C; Borges-Cosic, Milkana; Soriano-Maldonado, Alberto; Delgado-Fernández, Manuel; Segura-Jiménez, Víctor

    2017-05-01

    The aim of the present study was to determinate whether fitness cut-off points discriminate the severity of major fibromyalgia symptoms and health-related quality of life. Additionally, we investigated which American Colleague of Rheumatology (ACR) fibromyalgia criteria (1990 vs. modified 2010) better discriminate fibromyalgia symptomatology. A total of 488 women with fibromyalgia and 200 non-fibromyalgia (control) women participated. All participants underwent both the 1990 and the modified 2010 ACR preliminary criteria (hereinafter 1990c and m-2010c, respectively). We used fitness cut-off points (Senior Fitness Tests Battery plus handgrip strength test) to discriminate between presence and absence of fibromyalgia. Additionally, we employed several instruments to assess fibromyalgia symptoms. Fitness cut-off points discriminated between high and low levels of the main symptoms the disease in all age groups (P from fibromyalgia diagnosis and monitoring. Moreover, the effect size of the differences in symptoms between women with fibromyalgia and controls were overall larger using the m-2010c compared with the 1990c, except for the tender points count, reflecting better the polysymptomatic distress condition of fibromyalgia. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Age, Gender and Ethnic Differences in Prevalence of Overweight and Obesity in Asian American College Students and Their Parents Using Different BMI Cutoffs

    Science.gov (United States)

    Wang, Li Hui; Chen, Ying Chang; Ka Chung, Angela; Poon, George; Lew, Polong; Tam, Chick F.

    2007-01-01

    The objective was to determine if the WHO global BMI (kg/m[squared]) cutoffs for determining overweight and obesity in the general populations are appropriate for Asian populations and to consider whether population-specific cutoffs would be warranted. A nonrandomized biased sampling of 227 Asian Americans were composed of 149 college students,…

  15. Operational Windows for Dry-Wall and Wetted-Wall IFE Chambers

    International Nuclear Information System (INIS)

    Najmabadi, F.; Raffray, A.R.; Bromberg, L.

    2004-01-01

    The ARIES-IFE study was an integrated study of inertial fusion energy (IFE) chambers and chamber interfaces with the driver and target systems. Detailed analysis of various subsystems was performed parametrically to uncover key physics/technology uncertainties and to identify constraints imposed by each subsystem. In this paper, these constraints (e.g., target injection and tracking, thermal response of the first wall, and driver propagation and focusing) were combined to understand the trade-offs, to develop operational windows for chamber concepts, and to identify high-leverage research and development directions for IFE research. Some conclusions drawn in this paper are (a) the detailed characterization of the target yield and spectrum has a major impact on the chamber; (b) it is prudent to use a thin armor instead of a monolithic first wall for dry-wall concepts; (c) for dry-wall concepts with direct-drive targets, the most stringent constraint is imposed by target survival during the injection process; (d) for relatively low yield targets (<250 MJ), an operational window with no buffer gas may exist; (e) for dry-wall concepts with indirect-drive targets, a high buffer gas pressure would be necessary that may preclude propagation of the laser driver and require assisted pinch transport for the heavy-ion driver; and (f) generation and transport of aerosols in the chamber is the key feasibility issue for wetted-wall concepts

  16. Use of cut-off values as meaningfulness limits in probabilistic studies and its effect on NPPs risk assessment and safety improvement

    International Nuclear Information System (INIS)

    Petrangeli, G.; Valeri, A.; Zaffiro, C.

    1991-01-01

    This paper discusses the use of cut-off values in probabilistic risk assessment/probabilistic safety assessment (PRA/PSA) of nuclear power plants (NPPs), in order to explore under which conditions this practice may help improve the meaningfulness of the results of the analyses and safety of plants, and how it may affect the assessment of risk. Reference is made, in particular, to some past practical applications, also taken from the experience of the authors within the frame of the Italian licensing process. The paper describes the Italian probabilistic criteria which use probabilistic targets and cut-off values to assess safety and identify plant safety improvements. The rationale of the approach is also discussed in the paper and results of sample applications are illustrated. The paper concludes that the use of cut-off values, if properly implemented, could be productive to improve the plant safety as it helps the analyst to focus on a restricted field of analysis, ignoring lower probability and less known events. It also points out that cut-off values should be considered as living numbers to be lowered and even eliminated as soon as significant advancements are made, through research and operational experience, in the knowledge of the pertinent events

  17. Hard wall - soft wall - vorticity scattering in shear flow

    NARCIS (Netherlands)

    Rienstra, S.W.; Singh, D.K.

    2014-01-01

    An analytically exact solution, for the problem of lowMach number incident vorticity scattering at a hard-soft wall transition, is obtained in the form of Fourier integrals by using theWiener-Hopf method. Harmonic vortical perturbations of inviscid linear shear flow are scattered at the wall

  18. Hard wall - soft wall - vorticity scattering in shear flow

    NARCIS (Netherlands)

    Rienstra, S.W.; Singh, D.K.

    2014-01-01

    An analytically exact solution, for the problem of low Mach number incident vorticity scattering at a hard-soft wall transition, is obtained in the form of Fourier integrals by using the Wiener-Hopf method. Harmonic vortical perturbations of inviscid linear shear flow are scattered at the wall

  19. Scanning tunnelling microscope light emission: Finite temperature current noise and over cut-off emission.

    Science.gov (United States)

    Kalathingal, Vijith; Dawson, Paul; Mitra, J

    2017-06-14

    The spectral distribution of light emitted from a scanning tunnelling microscope junction not only bears its intrinsic plasmonic signature but is also imprinted with the characteristics of optical frequency fluc- tuations of the tunnel current. Experimental spectra from gold-gold tunnel junctions are presented that show a strong bias (V b ) dependence, curiously with emission at energies higher than the quantum cut-off (eV b ); a component that decays monotonically with increasing bias. The spectral evolution is explained by developing a theoretical model for the power spectral density of tunnel current fluctuations, incorporating finite temperature contribution through consideration of the quantum transport in the system. Notably, the observed decay of the over cut-off emission is found to be critically associated with, and well explained in terms of the variation in junction conductance with V b . The investigation highlights the scope of plasmon-mediated light emission as a unique probe of high frequency fluctuations in electronic systems that are fundamental to the electrical generation and control of plasmons.

  20. Regulation of cell wall biosynthesis.

    Science.gov (United States)

    Zhong, Ruiqin; Ye, Zheng-Hua

    2007-12-01

    Plant cell walls differ in their amount and composition among various cell types and even in different microdomains of the wall of a given cell. Plants must have evolved regulatory mechanisms controlling biosynthesis, targeted secretion, and assembly of wall components to achieve the heterogeneity in cell walls. A number of factors, including hormones, the cytoskeleton, glycosylphosphatidylinositol-anchored proteins, phosphoinositides, and sugar nucleotide supply, have been implicated in the regulation of cell wall biosynthesis or deposition. In the past two years, there have been important discoveries in transcriptional regulation of secondary wall biosynthesis. Several transcription factors in the NAC and MYB families have been shown to be the key switches for activation of secondary wall biosynthesis. These studies suggest a transcriptional network comprised of a hierarchy of transcription factors is involved in regulating secondary wall biosynthesis. Further investigation and integration of the regulatory players participating in the making of cell walls will certainly lead to our understanding of how wall amounts and composition are controlled in a given cell type. This may eventually allow custom design of plant cell walls on the basis of our needs.

  1. Plant cell wall extensibility: connecting plant cell growth with cell wall structure, mechanics, and the action of wall-modifying enzymes

    Energy Technology Data Exchange (ETDEWEB)

    Cosgrove, Daniel J.

    2015-11-25

    The advent of user-friendly instruments for measuring force/deflection curves of plant surfaces at high spatial resolution has resulted in a recent outpouring of reports of the ‘Young's modulus’ of plant cell walls. The stimulus for these mechanical measurements comes from biomechanical models of morphogenesis of meristems and other tissues, as well as single cells, in which cell wall stress feeds back to regulate microtubule organization, auxin transport, cellulose deposition, and future growth directionality. In this article I review the differences between elastic modulus and wall extensibility in the context of cell growth. Some of the inherent complexities, assumptions, and potential pitfalls in the interpretation of indentation force/deflection curves are discussed. Reported values of elastic moduli from surface indentation measurements appear to be 10- to >1000-fold smaller than realistic tensile elastic moduli in the plane of plant cell walls. Potential reasons for this disparity are discussed, but further work is needed to make sense of the huge range in reported values. The significance of wall stress relaxation for growth is reviewed and connected to recent advances and remaining enigmas in our concepts of how cellulose, hemicellulose, and pectins are assembled to make an extensible cell wall. A comparison of the loosening action of α-expansin and Cel12A endoglucanase is used to illustrate two different ways in which cell walls may be made more extensible and the divergent effects on wall mechanics.

  2. Influence of thyroid gland status on the thyroglobulin cutoff level in washout fluid from cervical lymph nodes of patients with recurrent/metastatic papillary thyroid cancer.

    Science.gov (United States)

    Lee, Jun Ho; Lee, Hyun Chul; Yi, Ha Woo; Kim, Bong Kyun; Bae, Soo Youn; Lee, Se Kyung; Choe, Jun-Ho; Kim, Jung-Han; Kim, Jee Soo

    2016-04-01

    The influence of serum thyroglobulin (Tg) and thyroidectomy status on Tg in fine-needle aspiration cytology (FNAC) washout fluid is unclear. A total of 282 lymph nodes were prospectively subjected to FNAC, fine-needle aspiration (FNA)-Tg measurement, and frozen and permanent biopsies. We evaluated the diagnostic performance of several predetermined FNA-Tg cutoff values for recurrence/metastasis in lymph nodes according to thyroidectomy status. The diagnostic performance of FNA-Tg varied according to thyroidectomy status. The optimized cutoff value of FNA-Tg was 2.2 ng/mL. However, among FNAC-negative lymph nodes, the FNA-Tg cutoff value of 0.9 ng/mL showed better diagnostic performance in patients with a thyroid gland. An FNA-Tg/serum-Tg cutoff ratio of 1 showed the best diagnostic performance in patients without a thyroid gland. Applying the optimal cutoff values of FNA-Tg according to thyroid gland status and serum Tg level facilitates the diagnostic evaluation of neck lymph node recurrences/metastases in patients with papillary thyroid carcinoma (PTC). © 2015 Wiley Periodicals, Inc. Head Neck 38: E1705-E1712, 2016. © 2015 Wiley Periodicals, Inc.

  3. Heterogeneous upper-bound finite element limit analysis of masonry walls out-of-plane loaded

    Science.gov (United States)

    Milani, G.; Zuccarello, F. A.; Olivito, R. S.; Tralli, A.

    2007-11-01

    A heterogeneous approach for FE upper bound limit analyses of out-of-plane loaded masonry panels is presented. Under the assumption of associated plasticity for the constituent materials, mortar joints are reduced to interfaces with a Mohr Coulomb failure criterion with tension cut-off and cap in compression, whereas for bricks both limited and unlimited strength are taken into account. At each interface, plastic dissipation can occur as a combination of out-of-plane shear, bending and torsion. In order to test the reliability of the model proposed, several examples of dry-joint panels out-of-plane loaded tested at the University of Calabria (Italy) are discussed. Numerical results are compared with experimental data for three different series of walls at different values of the in-plane compressive vertical loads applied. The comparisons show that reliable predictions of both collapse loads and failure mechanisms can be obtained by means of the numerical procedure employed.

  4. Eleven Years of Data on the Jefferson Scale of Empathy-Medical Student Version (JSE-S): Proxy Norm Data and Tentative Cutoff Scores.

    Science.gov (United States)

    Hojat, Mohammadreza; Gonnella, Joseph S

    2015-01-01

    This study was designed to provide typical descriptive statistics, score distributions and percentile ranks of the Jefferson Scale of Empathy-Medical Student version (JSE-S) of male and female medical school matriculants to serve as proxy norm data and tentative cutoff scores. The participants were 2,637 students (1,336 women and 1,301 men) who matriculated at Sidney Kimmel (formerly Jefferson) Medical College between 2002 and 2012, and completed the JSE at the beginning of medical school. Information extracted from descriptive statistics, score distributions and percentile ranks for male and female matriculants were used to develop proxy norm data and tentative cutoff scores. The score distributions of the JSE tended to be moderately skewed and platykurtic. Women obtained a significantly higher mean score (116.2 ± 9.7) than men (112.3 ± 10.8) on the JSE-S (t2,635 = 9.9, p norm data. The tentative cutoff score to identify low scorers was ≤ 95 for men and ≤ 100 for women. Our findings provide norm data and cutoff scores for admission decisions under certain conditions and for identifying students in need of enhancing their empathy. © 2015 S. Karger AG, Basel.

  5. The warm dark matter halo mass function below the cut-off scale

    Science.gov (United States)

    Angulo, Raul E.; Hahn, Oliver; Abel, Tom

    2013-10-01

    Warm dark matter (WDM) cosmologies are a viable alternative to the cold dark matter (CDM) scenario. Unfortunately, an accurate scrutiny of the WDM predictions with N-body simulations has proven difficult due to numerical artefacts. Here, we report on cosmological simulations that, for the first time, are devoid of those problems, and thus are able to accurately resolve the WDM halo mass function well below the cut-off. We discover a complex picture, with perturbations at different evolutionary stages populating different ranges in the halo mass function. On the smallest mass scales we can resolve, identified objects are typically centres of filaments that are starting to collapse. On intermediate mass scales, objects typically correspond to fluctuations that have collapsed and are in the process of relaxation, whereas the high-mass end is dominated by objects similar to haloes identified in CDM simulations. We then explicitly show how the formation of low-mass haloes is suppressed, which translates into a strong cut-off in the halo mass function. This disfavours some analytic formulations that predict a halo mass function that would extend well below the free streaming mass. We argue for a more detailed exploration of the formation of the smallest structures expected to form in a given cosmology, which, we foresee, will advance our overall understanding of structure formation.

  6. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  7. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  8. Waist circumference cut-off values to predict the incidence of hypertension: an estimation from a Brazilian population-based cohort.

    Science.gov (United States)

    Gus, M; Cichelero, F Tremea; Moreira, C Medaglia; Escobar, G Fortes; Moreira, L Beltrami; Wiehe, M; Fuchs, S Costa; Fuchs, F Danni

    2009-01-01

    Central obesity is a key component in the definition of the metabolic syndrome, but the cut-off values proposed to define abnormal values vary among different guidelines and are mostly based on cross-sectional studies. In this study, we identify the best cut-off values for waist circumference (WC) associated with the incidence of hypertension. Participants for this prospectively planned cohort study were 589 individuals who were free of hypertension and selected at random from the community of Porto Alegre, Brazil. Hypertension was defined by a blood pressure measurement >or= 140/90 mmHg or the use of blood pressure lowering drugs. A logistic regression model established the association between WC and the incidence of hypertension. A receiver operating characteristics (ROC) curve analysis was used to select the best WC cut-off point to predict the incidence of hypertension. During a mean follow-up of 5.5+/-0.9 years, 127 subjects developed hypertension. The hazard ratios for the development of hypertension, adjusted for age, baseline systolic blood pressure, alcohol consumption, gender and scholarship were 1.02 (95% CI; 1.00-1.04; P=0.02) for WC. The best cut-off WC values to predict hypertension were 87 cm in men and 80 cm in women, with an area under the curve of 0.56 (95% CI; 0.47-0.64; P=0.17) and 0.70 (95% CI; 0.63-0.77; Phypertension in individuals living in communities in Brazil, and this risk begins at lower values of WC that those recommended by some guidelines.

  9. Fourier phase analysis on equilibrium gated radionuclide ventriculography: range of phase spread and cut-off limits in normal individuals

    International Nuclear Information System (INIS)

    Ramaiah, Vijayaraghavan L.; Harish, B.; Sunil, H.V.; Selvakumar, Job; Ravi Kishore, A.G.; Nair, Gopinathan

    2011-01-01

    To define the range of phase spread on equilibrium gated radionuclide ventriculography (ERNV) in normal individuals and derive the cut-off limit for the parameters to detect cardiac dyssynchrony. ERNV was carried out in 30 individuals (age 53±23 years, 25 males and 5 females) who had no history of cardiovascular disease. They all had normal left ventricular ejection fraction (LVEF 55-70%) as determined by echocardiography, were in sinus rhythm, with normal QRS duration (≤120 msec) and normal coronary angiography. First harmonic phase analysis was performed on scintigraphic data acquired in best septal view. Left and right ventricular standard deviation (LVSD and RVSD, respectively) and interventricular mechanical delay (IVMD), the absolute difference of mean phase angles of right and left ventricle, were computed and expressed in milliseconds. Mean + 3 standard deviation (SD) was used to derive the cut-off limits. Average LVEF and duration of cardiac cycle in the study group were 62.5%±5.44% and 868.9±114.5 msec, respectively. The observations of LVSD, RVSD and right and left ventricular mean phase angles were shown to be normally distributed by Shapiro-Wilk test. Cut-off limits for LVSD, RVSD and IVMD were calculated to be 80 msec, 85 msec and 75 msec, respectively. Fourier phase analysis on ERNV is an effective tool for the evaluation of synchronicity of cardiac contraction. The cut-off limits of parameters of dyssynchrony can be used to separate heart failure patients with cardiac dyssynchrony from those without. ERNV can be used to select patients for cardiac resynchronization therapy. (author)

  10. Spontaneous and controlled-diameter synthesis of single-walled and few-walled carbon nanotubes

    Science.gov (United States)

    Inoue, Shuhei; Lojindarat, Supanat; Kawamoto, Takahiro; Matsumura, Yukihiko; Charinpanitkul, Tawatchai

    2018-05-01

    In this study, we explored the spontaneous and controlled-diameter growth of carbon nanotubes. We evaluated the effects of catalyst density, reduction time, and a number of catalyst coating on the substrate (for multi-walled carbon nanotubes) on the diameter of single-walled carbon nanotubes and the number of layers in few-walled carbon nanotubes. Increasing the catalyst density and reduction time increased the diameters of the carbon nanotubes, with the average diameter increasing from 1.05 nm to 1.86 nm for single-walled carbon nanotubes. Finally, we succeeded in synthesizing a significant double-walled carbon nanotube population of 24%.

  11. Regulation of Cell Wall Biogenesis in Saccharomyces cerevisiae: The Cell Wall Integrity Signaling Pathway

    Science.gov (United States)

    Levin, David E.

    2011-01-01

    The yeast cell wall is a strong, but elastic, structure that is essential not only for the maintenance of cell shape and integrity, but also for progression through the cell cycle. During growth and morphogenesis, and in response to environmental challenges, the cell wall is remodeled in a highly regulated and polarized manner, a process that is principally under the control of the cell wall integrity (CWI) signaling pathway. This pathway transmits wall stress signals from the cell surface to the Rho1 GTPase, which mobilizes a physiologic response through a variety of effectors. Activation of CWI signaling regulates the production of various carbohydrate polymers of the cell wall, as well as their polarized delivery to the site of cell wall remodeling. This review article centers on CWI signaling in Saccharomyces cerevisiae through the cell cycle and in response to cell wall stress. The interface of this signaling pathway with other pathways that contribute to the maintenance of cell wall integrity is also discussed. PMID:22174182

  12. Orbital wall fractures

    International Nuclear Information System (INIS)

    Iinuma, Toshitaka; Ishio, Ken-ichirou; Yoshinami, Hiroyoshi; Kuriyama, Jun-ichi; Hirota, Yoshiharu.

    1993-01-01

    A total of 59 cases of mild facial fractures (simple orbital wall fractures, 34 cases, other facial fractures, 25 cases) with the clinical suspects of orbital wall fractures were evaluated both by conventional views (Waters' and Caldwell views) and coronal CT scans. Conventional views were obtained, as an average, after 4 days and CT after 7 days of injuries. Both the medial wall and the floor were evaluated at two sites, i.e., anterior and posterior. The ethmoid-maxillary plate was also included in the study. The degree of fractures was classified as, no fractures, fractures of discontinuity, dislocation and fragmentation. The coronal CT images in bone window condition was used as reference and the findings were compared between conventional views and CT. The correct diagnosis was obtained as follows: orbital floor (anterior, 78%, posterior, 73%), medial orbital wall (anterior, 72%, posterior, 72%) and ethmoid-maxillary plate (64%). The false positive diagnosis was as follows: orbital floor (anterior only, 13%), medial orbital wall (anterior only, 7%) and ethmoid-maxillary plate (11%). The false negative diagnosis was as follows: orbital floor (anterior, 9%, posterior, 10%), medial orbital wall (anterior, 21%, posterior, 28%) and ethmoid-maxillary plate (21%). The results were compared with those of others in the past. (author)

  13. PREFACE: Domain wall dynamics in nanostructures Domain wall dynamics in nanostructures

    Science.gov (United States)

    Marrows, C. H.; Meier, G.

    2012-01-01

    Domain structures in magnetic materials are ubiquitous and have been studied for decades. The walls that separate them are topological defects in the magnetic order parameter and have a wide variety of complex forms. In general, their investigation is difficult in bulk materials since only the domain structure on the surface of a specimen is visible. Cutting the sample to reveal the interior causes a rearrangement of the domains into a new form. As with many other areas of magnetism, the study of domain wall physics has been revitalised by the advent of nanotechnology. The ability to fabricate nanoscale structures has permitted the formation of simplified and controlled domain patterns; the development of advanced microscopy methods has permitted them to be imaged and then modelled; subjecting them to ultrashort field and current pulses has permitted their dynamics to be explored. The latest results from all of these advances are described in this special issue. Not only has this led to results of great scientific beauty, but also to concepts of great applicability to future information technologies. In this issue the reader will find the latest results for these domain wall dynamics and the high-speed processes of topological structures such as domain walls and magnetic vortices. These dynamics can be driven by the application of magnetic fields, or by flowing currents through spintronic devices using the novel physics of spin-transfer torque. This complexity has been studied using a wide variety of experimental techniques at the edge of the spatial and temporal resolution currently available, and can be described using sophisticated analytical theory and computational modelling. As a result, the dynamics can be engineered to give rise to finely controlled memory and logic devices with new functionality. Moreover, the field is moving to study not only the conventional transition metal ferromagnets, but also complex heterostructures, novel magnets and even other

  14. A comparison of the cut-off effects for twisted mass, overlap and Creutz fermions at tree-level of perturbation theory

    International Nuclear Information System (INIS)

    Cichy, Krzysztof; Kujawa, Agnieszka

    2008-11-01

    In this paper we investigate the cutoff effects at tree-level of perturbation theory for three different lattice regularizations of fermions - maximally twisted mass Wilson, overlap and Creutz fermions. We show that all three kinds of fermions exhibit the expected O(a 2 ) scaling behaviour in the lattice spacing. Moreover, the size of these cutoff effects for the considered quantities i.e. the pseudoscalar correlation function C PS , the mass m PS and the decay constant f PS is comparable for all of them. (orig.)

  15. Measurement and interpretation of current transmission in a crossed-field diode below cutoff

    International Nuclear Information System (INIS)

    Vanderberg, B.H.; Eninger, J.E.

    1997-01-01

    Measurements on the current-voltage-magnetic field characteristics of a space-charge-limited cylindrical cross-field diode below cutoff are presented. The measured current is found to be lower than predicted by simple cold-fluid theory. This reduction combined with observed oscillations in the current can be explained by secondary electron emission from the anode, leading to an increase of space charge in the diode. copyright 1997 American Institute of Physics

  16. The Epidemiologic and Pharmacodynamic Cutoff Values of Tilmicosin against Haemophilus parasuis

    Directory of Open Access Journals (Sweden)

    Haihong eHao

    2016-03-01

    Full Text Available The aim of this study was to establish antimicrobial susceptibility breakpoints for tilmicosin against Haemophilus parasuis, which is an important pathogen of respiratory tract infections. The minimum inhibitory concentrations (MICs of 103 H. parasuis isolates were determined by the agar dilution method. The wild-type (WT distribution and epidemiologic cutoff value (ECV were evaluated by statistical analysis. The new bronchoaveolar lavage (BAL was used to establish intrapulmonary pharmacokinetic (PK model in swine. The pharmacokinetic (PK parameters of tilmicosin, both in pulmonary epithelial lining fluid (PELF and in plasma, were determined using high performance liquid chromatography (HPLC method and WinNonlin software. The pharmacodynamic cutoff (COPD was calculated using Monte Carlo simulation. Our results showed that 100% of WT isolates were covered when the ECV was set at 16μg/mL. The tilmicosin had concentration-dependent activity against H. parasuis. The PK data indicated that tilmicosin concentrations in PELF was rapidly increased to high levels at 4 hours and kept stable until 48 hours after drug administration, while the tilmicosin concentration in plasma reached maximum levels at 4 hours and continued to decrease during 4-72 hours. Using Monte Carlo simulation, COPD was defined as 1 μg/mL. Conclusively, the ECV and COPD of tilmicosin against H. parasuis were established for the first time based on the MIC distribution and PK-PD analysis in the target tissue, respectively. These values are of great importance for detection of tilmicosin-resistant H. parasuis and for effective treatment of clinical intrapulmonary infection caused by H. parasuis.

  17. Optimal cutoff points for HOMA-IR and QUICKI in the diagnosis of metabolic syndrome and non-alcoholic fatty liver disease: A population based study.

    Science.gov (United States)

    Motamed, Nima; Miresmail, Seyed Javad Haji; Rabiee, Behnam; Keyvani, Hossein; Farahani, Behzad; Maadi, Mansooreh; Zamani, Farhad

    2016-03-01

    The present study was carried out to determine the optimal cutoff points for homeostatic model assessment (HOMA-IR) and quantitative insulin sensitivity check index (QUICKI) in the diagnosis of metabolic syndrome (MetS) and non-alcoholic fatty liver disease (NAFLD). The baseline data of 5511 subjects aged ≥18years of a cohort study in northern Iran were utilized to analyze. Receiver operating characteristic (ROC) analysis was conducted to determine the discriminatory capability of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. Youden index was utilized to determine the optimal cutoff points of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. The optimal cutoff points for HOMA-IR in the diagnosis of MetS and NAFLD were 2.0 [sensitivity=64.4%, specificity=66.8%] and 1.79 [sensitivity=66.2%, specificity=62.2%] in men and were 2.5 [sensitivity=57.6%, specificity=67.9%] and 1.95 [sensitivity=65.1%, specificity=54.7%] in women respectively. Furthermore, the optimal cutoff points for QUICKI in the diagnosis of MetS and NAFLD were 0.343 [sensitivity=63.7%, specificity=67.8%] and 0.347 [sensitivity=62.9%, specificity=65.0%] in men and were 0.331 [sensitivity=55.7%, specificity=70.7%] and 0.333 [sensitivity=53.2%, specificity=67.7%] in women respectively. Not only the optimal cutoff points of HOMA-IR and QUICKI were different for MetS and NAFLD, but also different cutoff points were obtained for men and women for each of these two conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Electroweak bubble wall speed limit

    Energy Technology Data Exchange (ETDEWEB)

    Bödeker, Dietrich [Fakultät für Physik, Universität Bielefeld, 33501 Bielefeld (Germany); Moore, Guy D., E-mail: bodeker@physik.uni-bielefeld.de, E-mail: guymoore@ikp.physik.tu-darmstadt.de [Institut für Kernphysik, Technische Universität Darmstadt, Schlossgartenstraße 2, 64289 Darmstadt (Germany)

    2017-05-01

    In extensions of the Standard Model with extra scalars, the electroweak phase transition can be very strong, and the bubble walls can be highly relativistic. We revisit our previous argument that electroweak bubble walls can 'run away,' that is, achieve extreme ultrarelativistic velocities γ ∼ 10{sup 14}. We show that, when particles cross the bubble wall, they can emit transition radiation. Wall-frame soft processes, though suppressed by a power of the coupling α, have a significance enhanced by the γ-factor of the wall, limiting wall velocities to γ ∼ 1/α. Though the bubble walls can move at almost the speed of light, they carry an infinitesimal share of the plasma's energy.

  19. Verification arrangements for the proposed fissile material cut-off treaty

    International Nuclear Information System (INIS)

    Bragin, V.

    2001-01-01

    Since the mid-1950's, an agreement to terminate the production of fissile material for nuclear weapons has been on the agenda. On December 16, 1993, the UNGA adopted Resolution A/RES/48/75/L which recommends ''the negotiation in the most appropriate international forum of a non-discriminatory, multilateral and internationally and effectively verifiable treaty banning the production of fissile material for nuclear weapons and other nuclear explosive devices''. The proposed Fissile Material Cut-off Treaty (FMCT) is still one of the most important items on the multilateral disarmament and non-proliferation agenda. Successful achievement of the FMCT would be an important step towards the goal of eliminating nuclear weapons. (author)

  20. A comparison of the cut-off effects for twisted mass, overlap and Creutz fermions at tree-level of perturbation theory

    Energy Technology Data Exchange (ETDEWEB)

    Cichy, Krzysztof; Kujawa, Agnieszka [Adam Mickiewicz Univ., Poznan (Poland). Faculty of Physics; Gonzalez Lopez, Jenifer [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik]|[Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2008-11-15

    In this paper we investigate the cutoff effects at tree-level of perturbation theory for three different lattice regularizations of fermions - maximally twisted mass Wilson, overlap and Creutz fermions. We show that all three kinds of fermions exhibit the expected O(a{sup 2}) scaling behaviour in the lattice spacing. Moreover, the size of these cutoff effects for the considered quantities i.e. the pseudoscalar correlation function C{sub PS}, the mass m{sub PS} and the decay constant f{sub PS} is comparable for all of them. (orig.)

  1. The effect of partial poloidal wall sections on the wall stabilization of external kink modes

    International Nuclear Information System (INIS)

    Ward, D.J.

    1996-02-01

    An analysis of the effect on the wall stabilization of external kink modes due to toroidally continuous gaps in the resistive wall is performed. The effects with and without toroidal rotation are studied. For a high-β equilibrium, the mode structure is localized on the outboard side. Therefore, outboard gaps greatly increase the growth rate when there is no rotation. For resistive wall stabilization by toroidal rotation, the presence of gaps has the same effect as moving the wall farther away, i.e. destabilizing for the ideal plasma mode, and stabilizing for the resistive wall mode. The region of stability, in terms of wall position, is reduced in size and moved closer to the plasma. However, complete stabilization becomes possible at considerably reduced rotation frequencies. For a high-β, reverse-shear equilibrium both the resistive wall mode and the ideal plasma mode can be stabilized by close fitting discrete passive plates on the outboard side. The necessary toroidal rotation frequency to stabilize the resistive wall mode using these plates is reduced by a factor of three compared to that for a poloidally continuous and complete wall at the same plasma-wall separation. (author) 15 figs., 24 refs

  2. A Structurally Specialized Uniform Wall Layer is Essential for Constructing Wall Ingrowth Papillae in Transfer Cells

    Science.gov (United States)

    Xia, Xue; Zhang, Hui-Ming; Offler, Christina E.; Patrick, John W.

    2017-01-01

    Transfer cells are characterized by wall labyrinths with either a flange or reticulate architecture. A literature survey established that reticulate wall ingrowth papillae ubiquitously arise from a modified component of their wall labyrinth, termed the uniform wall layer; a structure absent from flange transfer cells. This finding sparked an investigation of the deposition characteristics and role of the uniform wall layer using a Vicia faba cotyledon culture system. On transfer of cotyledons to culture, their adaxial epidermal cells spontaneously trans-differentiate to a reticulate architecture comparable to their abaxial epidermal transfer cell counterparts formed in planta. Uniform wall layer construction commenced once adaxial epidermal cell expansion had ceased to overlay the original outer periclinal wall on its inner surface. In contrast to the dense ring-like lattice of cellulose microfibrils in the original primary wall, the uniform wall layer was characterized by a sparsely dispersed array of linear cellulose microfibrils. A re-modeled cortical microtubule array exerted no influence on uniform wall layer formation or on its cellulose microfibril organization. Surprisingly, formation of the uniform wall layer was not dependent upon depositing a cellulose scaffold. In contrast, uniform wall cellulose microfibrils were essential precursors for constructing wall ingrowth papillae. On converging to form wall ingrowth papillae, the cellulose microfibril diameters increased 3-fold. This event correlated with up-regulated differential, and transfer-cell specific, expression of VfCesA3B while transcript levels of other cellulose biosynthetic-related genes linked with primary wall construction were substantially down-regulated. PMID:29259611

  3. Instanton scale cutoff due to the introduction of link constraints in the functional integral

    International Nuclear Information System (INIS)

    Bachas, C.P.

    1981-01-01

    We compute the contribution of instantons of fixed scale rho to the Wilson loop of a square (plaquette) of size a, and compare the result to its asymptotic forms in the large- and small-a/rho limits. We deduce that the scale cutoff of instantons renormalizing the coupling of an effective lattice theory lies between 2a/3 and a

  4. Shear localization and effective wall friction in a wall bounded granular flow

    Science.gov (United States)

    Artoni, Riccardo; Richard, Patrick

    2017-06-01

    In this work, granular flow rheology is investigated by means of discrete numerical simulations of a torsional, cylindrical shear cell. Firstly, we focus on azimuthal velocity profiles and study the effect of (i) the confining pressure, (ii) the particle-wall friction coefficient, (iii) the rotating velocity of the bottom wall and (iv) the cell diameter. For small cell diameters, azimuthal velocity profiles are nearly auto-similar, i.e. they are almost linear with the radial coordinate. Different strain localization regimes are observed : shear can be localized at the bottom, at the top of the shear cell, or it can be even quite distributed. This behavior originates from the competition between dissipation at the sidewalls and dissipation in the bulk of the system. Then we study the effective friction at the cylindrical wall, and point out the strong link between wall friction, slip and fluctuations of forces and velocities. Even if the system is globally below the sliding threshold, force fluctuations trigger slip events, leading to a nonzero wall slip velocity and an effective wall friction coefficient different from the particle-wall one. A scaling law was found linking slip velocity, granular temperature in the main flow direction and effective friction. Our results suggest that fluctuations are an important ingredient for theories aiming to capture the interface rheology of granular materials.

  5. Accurate cut-offs for predicting endoscopic activity and mucosal healing in Crohn's disease with fecal calprotectin

    Directory of Open Access Journals (Sweden)

    Juan María Vázquez-Morón

    Full Text Available Background: Fecal biomarkers, especially fecal calprotectin, are useful for predicting endoscopic activity in Crohn's disease; however, the cut-off point remains unclear. The aim of this paper was to analyze whether faecal calprotectin and M2 pyruvate kinase are good tools for generating highly accurate scores for the prediction of the state of endoscopic activity and mucosal healing. Methods: The simple endoscopic score for Crohn's disease and the Crohn's disease activity index was calculated for 71 patients diagnosed with Crohn's. Fecal calprotectin and M2-PK were measured by the enzyme-linked immunosorbent assay test. Results: A fecal calprotectin cut-off concentration of ≥ 170 µg/g (sensitivity 77.6%, specificity 95.5% and likelihood ratio +17.06 predicts a high probability of endoscopic activity, and a fecal calprotectin cut-off of ≤ 71 µg/g (sensitivity 95.9%, specificity 52.3% and likelihood ratio -0.08 predicts a high probability of mucosal healing. Three clinical groups were identified according to the data obtained: endoscopic activity (calprotectin ≥ 170, mucosal healing (calprotectin ≤ 71 and uncertainty (71 > calprotectin < 170, with significant differences in endoscopic values (F = 26.407, p < 0.01. Clinical activity or remission modified the probabilities of presenting endoscopic activity (100% vs 89% or mucosal healing (75% vs 87% in the diagnostic scores generated. M2-PK was insufficiently accurate to determine scores. Conclusions: The highly accurate scores for fecal calprotectin provide a useful tool for interpreting the probabilities of presenting endoscopic activity or mucosal healing, and are valuable in the specific clinical context.

  6. Epidemiological cut-off values for Flavobacterium psychrophilum MIC data generated by a standard test protocol

    DEFF Research Database (Denmark)

    Smith, P.; Endris, R.; Kronvall, G.

    2016-01-01

    -1 for florfenicol, ≤0.025 mg L-1 for oxolinic acid (OXO), ≤0.125 mg L-1 for oxytetracycline and ≤20 (1/19) mg L-1 for trimethoprim/sulphamethoxazole. For ampicillin and amoxicillin, the majority of putative wild-type observations were 'off scale', and therefore, statistically valid cut-off values...

  7. The role of wall calcium in the extension of cell walls of soybean hypocotyls

    Science.gov (United States)

    Virk, S. S.; Cleland, R. E.

    1990-01-01

    Calcium crosslinks are load-bearing bonds in soybean (Glycine max (L.) Merr.) hypocotyl cell walls, but they are not the same load-bearing bonds that are broken during acid-mediated cell elongation. This conclusion is reached by studying the relationship between wall calcium, pH and the facilitated creep of frozen-thawed soybean hypocotyl sections. Supporting data include the following observations: 1) 2-[(2-bis-[carboxymethyl]amino-5-methylphenoxy)methyl]-6-methoxy-8-bis[car boxymethyl]aminoquinoline (Quin 2) and ethylene glycol-bis(2-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) caused only limited facilitated creep as compared with acid, despite removal of comparable or larger amounts of wall calcium; 2) the pH-response curves for calcium removal and acid-facilitated creep were different; 3) reversible acid-extension occurred even after removal of almost all wall calcium with Quin 2; and 4) growth of abraded sections did not involve a proportional loss of wall calcium. Removal of wall calcium, however, increased the capacity of the walls to undergo acid-facilitated creep. These data indicate that breakage of calcium crosslinks is not a major mechanism of cell-wall loosening in soybean hypocotyl tissues.

  8. Methods for identifying the cost effective case definition cut-off for sequential monitoring tests: an extension of Phelps and Mushlin

    Science.gov (United States)

    Longo, Roberta; Baxter, Paul; Hall, Peter; Hewison, Jenny; Afshar, Mehran; Hall, Geoff; McCabe, Christopher

    2015-01-01

    The arrival of personalized medicine in the clinic means that treatment decisions will increasingly rely on test results. The challenge of limited health care resources means that the dissemination of these technologies will be dependent on their value in relation to their cost; i.e. their cost effectiveness. Phelps and Mushlin have described how to optimize tests to meet cost effectiveness target. However, when tests are applied repeatedly the case mix of the patients tested changes with each administration, and this impacts upon the value of each subsequent test administration. In this paper we present a modification of Phelps and Mushlin’s framework for diagnostic tests; to identify the cost effective cut-off for monitoring tests. Using the Ca125 test monitoring for relapse in Ovarian Cancer, we show how the repeated use of the initial cut-off can lead to a substantially increased false negative rate compared to the monitoring cut-off – over 20% higher than in this example – with the associated harms for individual and population health. PMID:24488576

  9. Granular packings with moving side walls

    International Nuclear Information System (INIS)

    Landry, James W.; Grest, Gary Stephen

    2004-01-01

    The effects of movement of the side walls of a confined granular packing are studied by discrete element, molecular dynamics simulations. The dynamical evolution of the stress is studied as a function of wall movement both in the direction of gravity as well as opposite to it. For all wall velocities explored, the stress in the final state of the system after wall movement is fundamentally different from the original state obtained by pouring particles into the container and letting them settle under the influence of gravity. The original packing possesses a hydrostaticlike region at the top of the container which crosses over to a depth-independent stress. As the walls are moved in the direction opposite to gravity, the saturation stress first reaches a minimum value independent of the wall velocity, then increases to a steady-state value dependent on the wall velocity. After wall movement ceases and the packing reaches equilibrium, the stress profile fits the classic Janssen form for high wall velocities, while some deviations remain for low wall velocities. The wall movement greatly increases the number of particle-wall and particle-particle forces at the Coulomb criterion. Varying the wall velocity has only small effects on the particle structure of the final packing so long as the walls travel a similar distance.

  10. Optimal cut-off levels to define obesity: body mass index and waist circumference, and their relationship to cardiovascular disease, dyslipidaemia, hypertension and diabetes in Malaysia.

    Science.gov (United States)

    Zaher, Zaki Morad Mohd; Zambari, Robayaah; Pheng, Chan Siew; Muruga, Vadivale; Ng, Bernard; Appannah, Geeta; Onn, Lim Teck

    2009-01-01

    Many studies in Asia have demonstrated that Asian populations may require lower cut-off levels for body mass index (BMI) and waist circumference to define obesity and abdominal obesity respectively, compared to western populations. Optimal cut-off levels for body mass index and waist circumference were determined to assess the relationship between the two anthropometric- and cardiovascular indices. Receiver operating characteristics analysis was used to determine the optimal cut-off levels. The study sample included 1833 subjects (mean age of 44+/-14 years) from 93 primary care clinics in Malaysia. Eight hundred and seventy two of the subjects were men and 960 were women. The optimal body mass index cut-off values predicting dyslipidaemia, hypertension, diabetes mellitus, or at least one cardiovascular risk factor varied from 23.5 to 25.5 kg/m2 in men and 24.9 to 27.4 kg/m2 in women. As for waist circumference, the optimal cut-off values varied from 83 to 92 cm in men and from 83 to 88 cm in women. The optimal cut-off values from our study showed that body mass index of 23.5 kg/m2 in men and 24.9 kg/m2 in women and waist circumference of 83 cm in men and women may be more suitable for defining the criteria for overweight or obesity among adults in Malaysia. Waist circumference may be a better indicator for the prediction of obesity-related cardiovascular risk factors in men and women compared to BMI. Further investigation using a bigger sample size in Asia needs to be done to confirm our findings.

  11. Comparison of interferon-γ release assay to two cut-off points of tuberculin skin test to detect latent Mycobacterium tuberculosis infection in primary health care workers.

    Directory of Open Access Journals (Sweden)

    Fernanda Mattos de Souza

    Full Text Available An interferon-γ release assay, QuantiFERON-TB (QFT test, has been introduced an alternative test for the diagnosis of latent Mycobacterium tuberculosis infection (LTBI. Here, we compared the performance of QFT with tuberculin skin test (TST measured at two different cut-off points among primary health care work (HCW in Brazil.A cross-sectional study was carried out among HCWs in four Brazilian cities with a known history of high incidence of TB. Results of the QFT were compared to TST results based on both ≥5 mm and ≥10 mm as cut-off points.We enrolled 632 HCWs. When the cut-off value of ≥10 mm was used, agreement between QFT and TST was 69% (k = 0.31, and when the cut-off of ≥5 mm was chosen, the agreement was 57% (k = 0.22. We investigated possible factors of discordance of TST vs QFT. Compared to the TST-/QFT- group, risk factors for discordance in the TST+/QFT- group with TST cut-off of ≥5 mm included age between 41-45 years [OR = 2.70; CI 95%: 1.32-5.51] and 46-64 years [OR = 2.04; CI 95%: 1.05-3.93], BCG scar [OR = 2.72; CI 95%: 1.40-5.25], and having worked only in primary health care [OR = 2.30; CI 95%: 1.09-4.86]. On the other hand, for the cut-off of ≥10 mm, BCG scar [OR = 2.26; CI 95%: 1.03-4.91], being a household contact of a TB patient [OR = 1.72; CI 95%: 1.01-2.92] and having had a previous TST [OR = 1.66; CI 95%: 1.05-2.62], were significantly associated with the TST+/QFT- group. No statistically significant associations were found among the TST-/QFT+ discordant group with either TST cut-off value.Although we identified BCG vaccination to contribute to the discordance at both TST cut-off measures, the current Brazilian recommendation for the initiation of LTBI treatment, based on information gathered from medical history, TST, chest radiograph and physical examination, should not be changed.

  12. Comparison of interferon-γ release assay to two cut-off points of tuberculin skin test to detect latent Mycobacterium tuberculosis infection in primary health care workers.

    Science.gov (United States)

    de Souza, Fernanda Mattos; do Prado, Thiago Nascimento; Pinheiro, Jair dos Santos; Peres, Renata Lyrio; Lacerda, Thamy Carvalho; Loureiro, Rafaela Borge; Carvalho, Jose Américo; Fregona, Geisa; Dias, Elias Santos; Cosme, Lorrayne Beliqui; Rodrigues, Rodrigo Ribeiro; Riley, Lee Wood; Maciel, Ethel Leonor Noia

    2014-01-01

    An interferon-γ release assay, QuantiFERON-TB (QFT) test, has been introduced an alternative test for the diagnosis of latent Mycobacterium tuberculosis infection (LTBI). Here, we compared the performance of QFT with tuberculin skin test (TST) measured at two different cut-off points among primary health care work (HCW) in Brazil. A cross-sectional study was carried out among HCWs in four Brazilian cities with a known history of high incidence of TB. Results of the QFT were compared to TST results based on both ≥5 mm and ≥10 mm as cut-off points. We enrolled 632 HCWs. When the cut-off value of ≥10 mm was used, agreement between QFT and TST was 69% (k = 0.31), and when the cut-off of ≥5 mm was chosen, the agreement was 57% (k = 0.22). We investigated possible factors of discordance of TST vs QFT. Compared to the TST-/QFT- group, risk factors for discordance in the TST+/QFT- group with TST cut-off of ≥5 mm included age between 41-45 years [OR = 2.70; CI 95%: 1.32-5.51] and 46-64 years [OR = 2.04; CI 95%: 1.05-3.93], BCG scar [OR = 2.72; CI 95%: 1.40-5.25], and having worked only in primary health care [OR = 2.30; CI 95%: 1.09-4.86]. On the other hand, for the cut-off of ≥10 mm, BCG scar [OR = 2.26; CI 95%: 1.03-4.91], being a household contact of a TB patient [OR = 1.72; CI 95%: 1.01-2.92] and having had a previous TST [OR = 1.66; CI 95%: 1.05-2.62], were significantly associated with the TST+/QFT- group. No statistically significant associations were found among the TST-/QFT+ discordant group with either TST cut-off value. Although we identified BCG vaccination to contribute to the discordance at both TST cut-off measures, the current Brazilian recommendation for the initiation of LTBI treatment, based on information gathered from medical history, TST, chest radiograph and physical examination, should not be changed.

  13. Plasma-wall interactions

    International Nuclear Information System (INIS)

    Behrisch, Rainer

    1978-01-01

    The plasma wall interactions for two extreme cases, the 'vacuum model' and the 'cold gas blanket' are outlined. As a first step for understanding the plasma wall interactions the elementary interaction processes at the first wall are identified. These are energetic ion and neutral particle trapping and release, ion and neutral backscattering, ion sputtering, desorption by ions, photons and electrons and evaporation. These processes have only recently been started to be investigated in the parameter range of interest for fusion research. The few measured data and their extrapolation into regions not yet investigated are reviewed

  14. Modal analysis and cut-off conditions of multichannel surface-acoustic-waveguide structures.

    Science.gov (United States)

    Griffel, G; Golan, G; Ruschin, S; Seidman, A; Croitoru, N

    1988-01-01

    Multichannel guides for surface acoustic waves can improve the efficiency of SAW (surface acoustic-wave) devices significantly. Focusing, steering, and modulating the propagating acoustical modes can be achieved similarly to optical waveguided devices. A general formulation is presented for the analysis of the lateral waveguiding properties of Rayleigh modes in surfaces loaded with deposited strips of different materials. General expressions are obtained for the number of modes and cutoff conditions in these structures. As examples of applications, a simple directional coupler and an electrically controlled coupler are proposed.

  15. Cut-off value of FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction in a Korean population

    Directory of Open Access Journals (Sweden)

    Chung KS

    2016-08-01

    Full Text Available Kyung Soo Chung,1,2 Ji Ye Jung,1,2 Moo Suk Park,1,2 Young Sam Kim,1,2 Se Kyu Kim,1,2 Joon Chang,1,2 Joo Han Song1,2 1Division of Pulmonology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea; 2Institute of Chest Disease, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea Background: Forced expiratory volume in 1 second (FEV1/forced expiratory volume in 6 seconds (FEV6 has been proposed as an alternative to FEV1/forced vital capacity (FVC for detecting airway obstruction. A fixed cut-off value for FEV1/FEV6 in a Korean population is lacking. We investigated a fixed cut-off for FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction.Materials and methods: We used data obtained in the 5 years of the Fifth and Sixth Korean National Health and Nutrition Examination Survey. A total of 14,978 participants aged ≥40 years who underwent spirometry adequately were the study cohort. “Airway obstruction” was a fixed cut-off FEV1/FVC <70% according to the Global Initiative for Chronic Obstructive Lung Disease guidelines. We also used European Respiratory Society/Global Lung Initiative 2012 equations for the FEV1/FVC lower limit of normal.Results: Among the 14,978 participants (43.5% male, 56.5% female; mean age: 56.9 years for men and 57.0 years for women, 14.0% had obstructive lung function according to a fixed cut-off FEV1/FVC <70%. Optimal FEV1/FEV6 cut-off for predicting FEV1/FVC <70% was 75% using receiver operating characteristic curve analyses (area under receiver operating characteristic curve =0.989, 95% confidence interval 0.987–0.990. This fixed cut-off of FEV1/FEV6 showed 93.8% sensitivity, 94.8% specificity, 74.7% positive predictive value, 98.9% negative predictive value, and 0.8 Cohen’s kappa coefficient. When compared with FEV1/FVC < lower limit of normal, FEV1/FEV6 <75% tended to over-diagnose airflow limitation (just like a fixed cut-off

  16. Dynamic wall demonstration project

    Energy Technology Data Exchange (ETDEWEB)

    Nakatsui, L.; Mayhew, W.

    1990-12-01

    The dynamic wall concept is a ventilation strategy that can be applied to a single family dwelling. With suitable construction, outside air can be admitted through the exterior walls of the house to the interior space to function as ventilation air. The construction and performance monitoring of a demonstration house built to test the dynamic wall concept in Sherwood Park, Alberta, is described. The project had the objectives of demonstrating and assessing the construction methods; determining the cost-effectiveness of the concept in Alberta; analyzing the operation of the dynamic wall system; and determining how other components and systems in the house interact with the dynamic wall. The exterior wall construction consisted of vinyl siding, spun-bonded polyolefin-backed (SBPO) rigid fiberglass sheathing, 38 mm by 89 mm framing, fiberglass batt insulation and 12.7 mm drywall. The mechanical system was designed to operate in the dynamic (negative pressure) mode, however flexibility was provided to allow operation in the static (balanced pressure) mode to permit monitoring of the walls as if they were in a conventional house. The house was monitored by an extensive computerized monitoring system. Dynamic wall operation was dependent on pressure and temperature differentials between indoor and outdoor as well as wind speed and direction. The degree of heat gain was found to be ca 74% of the indoor-outdoor temperature differential. Temperature of incoming dynamic air was significantly affected by solar radiation and measurement of indoor air pollutants found no significant levels. 4 refs., 34 figs., 11 tabs.

  17. Unipolar Endocardial Voltage Mapping in the Right Ventricle: Optimal Cutoff Values Correcting for Computed Tomography-Derived Epicardial Fat Thickness and Their Clinical Value for Substrate Delineation.

    Science.gov (United States)

    Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja

    2017-08-01

    Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance 1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV the remaining could be identified by corresponding low endocardial UV right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.

  18. Enhanced wall pumping in JET

    International Nuclear Information System (INIS)

    Ehrenberg, J.; Harbour, P.J.

    1991-01-01

    The enhanced wall pumping phenomenon in JET is observed for hydrogen or deuterium plasmas which are moved from the outer (larger major radius) limiter position either to the inner wall or to the top/bottom wall of the vacuum vessel. This phenomenon is analysed by employing a particle recycling model which combines plasma particle transport with particle re-emission from and retention within material surfaces. The model calculates the important experimentally observable quantities, such as particle fluxes, global particle confinement time, plasma density and density profile. Good qualitative agreement is found and, within the uncertainties, the agreement is quantitative if the wall pumping is assumed to be caused by two simultaneously occurring effects: (1) Neutral particle screening at the inner wall and the top/bottom wall is larger than that at the outer limiter because of different magnetic topologies at different poloidal positions; and (2) although most of the particles (≥ 90%) impacting on the wall can be promptly re-emitted, a small fraction (≤ 10%) of them must be retained in the wall for a period of time which is similar to or larger than the global plasma particle confinement time. However, the wall particle retention time need not be different from that of the outer limiter, i.e. pumping can occur when there is no difference between the material properties of the limiter and those of the wall. (author). 45 refs, 18 figs

  19. Validation of the Cepstral Spectral Index of Dysphonia (CSID) as a Screening Tool for Voice Disorders: Development of Clinical Cutoff Scores.

    Science.gov (United States)

    Awan, Shaheen N; Roy, Nelson; Zhang, Dong; Cohen, Seth M

    2016-03-01

    The purposes of this study were to (1) evaluate the performance of the Cepstral Spectral Index of Dysphonia (CSID--a multivariate estimate of dysphonia severity) as a potential screening tool for voice disorder identification and (2) identify potential clinical cutoff scores to classify voice-disordered cases versus controls. Subjects were 332 men and women (116 men, 216 women) comprised of subjects who presented to a physician with a voice-related complaint and a group of non-voice-related control subjects. Voice-disordered cases versus controls were initially defined via three reference standards: (1) auditory-perceptual judgment (dysphonia +/-); (2) Voice Handicap Index (VHI) score (VHI +/-); and (3) laryngoscopic description (laryngoscopic +/-). Speech samples were analyzed using the Analysis of Dysphonia in Speech and Voice program. Cepstral and spectral measures were combined into a CSID multivariate formula which estimated dysphonia severity for Rainbow Passage samples (i.e., the CSIDR). The ability of the CSIDR to accurately classify cases versus controls in relation to each reference standard was evaluated via a combination of logistic regression and receiver operating characteristic (ROC) analyses. The ability of the CSIDR to discriminate between cases and controls was represented by the "area under the ROC curve" (AUC). ROC classification of dysphonia-positive cases versus controls resulted in a strong AUC = 0.85. A CSIDR cutoff of ≈24 achieved the best balance between sensitivity and specificity, whereas a more liberal cutoff score of ≈19 resulted in higher sensitivity while maintaining respectable specificity which may be preferred for screening purposes. Weaker but adequate AUCs = 0.75 and 0.73 were observed for the classification of VHI-positive and laryngoscopic-positive cases versus controls, respectively. Logistic regression analyses indicated that subject age may be a significant covariate in the discrimination of dysphonia-positive and VHI

  20. Fuel retention under elevated wall temperature in KSTAR with a carbon wall

    Science.gov (United States)

    Cao, B.; Hong, S. H.

    2018-03-01

    The fuel retention during KSTAR discharges with elevated wall temperature (150 °C) has been studied by using the method of global particle balance. The results show that the elevated wall temperature could reduce the dynamic retention via implantation and absorption, especially for the short pulse shots with large injected fuel particles. There is no signature changing of long-term retention, which related to co-deposition, under elevated wall temperature. For soft-landing shots (normal shots), the exhausted fuel particles during discharges is larger with elevated wall temperature than without, but the exhausted particles after discharges within 90 s looks similar. The outgassing particles because of disruption could be exhausted within 15 s.

  1. Establishing the cut-off score for remission and severity-ranges on the Psychotic Depression Assessment Scale (PDAS)

    DEFF Research Database (Denmark)

    Østergaard, Søren D; Rothschild, Anthony J; Flint, Alastair J

    2016-01-01

    BACKGROUND: The Psychotic Depression Assessment Scale (PDAS) is a rating scale dedicated to the measurement of severity in psychotic depression (PD). The aim of this study was to establish the PDAS cut-off for remission of PD as well as PDAS score-ranges for mild, moderate, and severe PD...... on the PDAS and the severity-ranges for mild, moderate, and severe PD were defined using the Clinical Global Impression - Severity scale (CGI-S) as reference by means of pair-wise receiver operating characteristic (ROC) analyses. Subsequently, it was tested whether remission on the PDAS could separate...... the effects of Olanzapine+Sertraline vs. Olanzapine+Placebo through an intention-to-treat, mixed-effects logistic regression of the data from STOP-PD. RESULTS: According to the ROC analyses, the ideal cut-off for remission of PD was a PDAS total score moderate...

  2. Appraisal and standardization of curvilinear velocity (VCL) cut-off values for CASA analysis of Japanese quail (Coturnix japonica) sperm.

    Science.gov (United States)

    Farooq, U; Malecki, I A; Mahmood, M; Martin, G B

    2017-06-01

    One of the basic steps in objective analysis of sperm motility is the subdivision of a motile sperm population into slow, medium and rapid categories based on their velocity. However, for CASA analysis of quail sperm, the velocity values for categorization of slow, medium and rapid sperm have not yet been standardized. To identify the cut-off values of "velocity curvilinear" (VCL) for quail sperm categorization, we captured and analysed 22,300 tracks of quail sperm using SCA ® -CASA. The median and mean VCL values were 85 and 97 μm/s. To define the VCL cut-off values, we used two methods. In the first, we identified the upper (rapid sperm) and lower (slow sperm) cut-off values using: (i) median VCL ± 25% or ± 50% or ± 75% of median VCL value; (ii) first and third quartile values of VCL data (i.e. 25% cut-off setting); and (iii) 33% and 66% of VCL data. Among these settings, sperm categories and their corresponding motility characteristics recorded using the "25%" setting (i.e. slow ≤36 ≤ medium ≤154 ≤ rapid) were found the most realistic and coherent with male ranking by fertility. In the second method, we calculated heteroscedasticity in the total VCL data using PCA and the two-step clustering method. With this approach, the mean of the high and low clusters was 165 and 51 μm/s, respectively. Together, the mean from two methods suggested that, for SCA ® -CASA categorization of quail sperm, sperm should be classed as "rapid" at VCL ≥160 μm/s and "slow" at VCL ≤45 μm/s. © 2017 Blackwell Verlag GmbH.

  3. Effect of Irrigation CutOff on Flowering Stage and Foliar Application of Spermidine on Some Quantitative and Qualitative Characteristics of Various Ecotypes of Cumin

    Directory of Open Access Journals (Sweden)

    Sarah Bakhtari

    2017-02-01

    Full Text Available Introduction: Medicinal plants play major roles in human health. . Cumin (Cuminum cyminum L. is an annual plant that commonly cultivated in arid and semiarid regions of Iran. The crop has a wide range of uses including medicinal, cosmetic and food industry. Cumin occupies about 26% of the total area devoted to medicinal plants in Iran. However, cumin is seriously affected by the Fusarium wilt and blight diseases. The diseases usually increase under warm and wet conditions. It was demonstrated that the peak of the disease incidence is occurring at the flowering stage and irrigation cutoff at this time may be reduced the diseases density. Materials and methods: In order to evaluate the effects of irrigation cutoff in flowering stage and foliar application of spermidine on some characteristics of various ecotype of cumin, an experiment was conducted in a split-split-plot arrangement in randomized complete block design with three replications at the research farm of Shahid Bahonar University of Kerman at 2014. The experimental treatments were irrigation in two levels (complete irrigation and cutoff the irrigation in flowering stage assigned to main plots, foliar application of spermidine in three levels (0, 1 and 2 Mm as a subplot and cumin ecotypes in three levels (Kerman, Khorasan and Esfahan that was randomized in sub-subplot. Plots size under the trial was 4 m × 3 m so as to get 50 cm inter row spacing in six rows. The ideal density of the crops was considered as 120 plant m-2. As soon as the seeds were sown, irrigation was applied every 10 days. Foliar application of spermidine was done at three stages (after thinning, before flowering stage and in the middle of flowering stage. No herbicides and chemical fertilizers were applied during the expriments. Results and discussion: In this study the number of branches, umbels per plant, 1000-seed weight, seed yield per plant and hectare, harvest index, essential oil percentage and yield, infected

  4. International Divider Walls

    NARCIS (Netherlands)

    Kruis, A.; Sneller, Lineke

    2013-01-01

    The subject of this teaching case is the Enterprise Resource Planning (ERP) system implementation at International Divider Walls, the world market leader in design, production, and sales of divider walls. The implementation in one of the divisions of this multinational company had been successful,

  5. Quantum fields and Poisson processes: Interaction of a cut-off boson field with a quantum particle

    International Nuclear Information System (INIS)

    Bertrand, J.; Rideau, G.; Gaveau, B.

    1985-01-01

    The solution of the Schroedinger equation for a boson field interacting with a quantum particle is written as an expectation on a Poisson process counting the variations of the boson-occupation numbers for each momentum. An energy cut-off is needed for the expectation to be meaningful. (orig.)

  6. [Analysis of Cut-off Value in Screening of Thalassemia by Capillary Hemoglobin Electrophoresis for Pregnant Women from Shenzhen Region of China].

    Science.gov (United States)

    Huo, Mei; Wu, Wen-Yuan; Liu, Mei; Gan, Zhi-Biao; Mao, Wei-Yu; Lin, Rong-Yao; Liu, Ai-Qin; He, Gui-Rong

    2016-04-01

    To investigate the cut-off value in screening of thalassemia in pregnant women from Shenzhen region by capillary hemoglobin electrophoresis. The data of capillary hemoglobin electrophoresis and genetic diagnosis of thalassemia from 2122 examined prenatal women were retrospectively analyzed. Capillary hemoglobin electrophoresis and α-, β- genetic diagnosis of thalassemia were carried out for every woman. Hemoglobin electrophoresis was performed using Capillarys 2 full-automated electrophoresis instrument. Gap polymerase chain reaction and reverse dot blot were used for genetic diagnosis of thalassemia genotyping test. The cut-off value in screening of thalassemia was determined by receiver operating characteristic curve and next to analyze the value of HbA2 and HbF in screening of thalassemia using the decided cut-off value. The areas under the curve (AUC(Roc)) of HbA2 for diagnosis of α-, β- thalassemia were 0.75 and 0.981 respectively, and the AUC(Roc) of HbF for diagnosis of β-thalassemia was 0.787. When HbA2 ≤ 2.55 was taken as the cut-off value of HbA2 for diagnosis of α-thalassemia, the sensitivity, specificity, positive likelihood ratio (LR(+)) and negative likelihood ratio (LR(-)) were 89.5%, 54.8%, 1.98, 0.19 respectively. When HbA2 ≥3.9 was taken as the cut off value of HbA2 for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 96.1%, 99.8% 480.5, 0.04 respectively. When HbF ≥0.75 was taken as the cut off value of HbF for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 83.6%, 61.8% respectively. The cut-off value in screening of thalassemia by capillarys 2 full automated electrophoresis instrument is different from that of the traditional method of hemoglobin electrophoresis, such as cellulose acetate membrane electrophoresis and agarose gel electrophoresis. Each laboratory should establish their own respective cut off value.

  7. Cutoff value of thyroid uptake of (99m)Tc-pertechnetate to discriminate between Graves' disease and painless thyroiditis: a single center retrospective study.

    Science.gov (United States)

    Uchida, Toyoyoshi; Suzuki, Ruriko; Kasai, Takatoshi; Onose, Hiroyuki; Komiya, Koji; Goto, Hiromasa; Takeno, Kageumi; Ishii, Shinya; Sato, Junko; Honda, Akira; Kawano, Yui; Himuro, Miwa; Yamada, Emiko; Yamada, Tetsu; Watada, Hirotaka

    2016-01-01

    Thyroid uptake of (99m)Tc-pertechnetate is a useful way to determine the cause of thyrotoxicosis. In daily clinical practice, (99m)Tc-pertechnetate uptake is used to discriminate between Graves' disease and painless thyroiditis when clinical information is not enough to make the distinction. However, since the optimal cutoff value of (99m)Tc-pertechnetate uptake has not yet been elucidated, our aim was to determine this value. We recruited patients with thyrotoxicosis in whom (99m)Tc-pertechnetate uptake was measured in clinical settings between 2009 and 2013. Three experienced endocrinologists (who were blinded to the value of (99m)Tc-pertechnetate uptake and initial treatment) diagnosed the cause of thyrotoxicosis based on thyrotropin, free triiodothyronine, free thyroxine, and thyrotropin receptor antibody levels, and by ultrasound findings and using images of thyroid uptake of (99m)Tc-pertechnetate without the actual values. Ninety-four patients diagnosed as having Graves' disease or painless thyroiditis were finally included. According to the diagnosis, the optimal cutoff value of (99m)Tc-pertechnetate uptake was determined by receiver operating characteristics analysis. A cutoff value of 1.0% provided optimal sensitivity and specificity of 96.6% and 97.1%, respectively. Then, its validity was confirmed in 78 patients with confirmed Graves' disease or painless thyroiditis diagnosed at another institute. Applying this cutoff value to the patients with thyrotoxicosis revealed positive and negative predictive values for Graves' disease of 100% and 88.9%, respectively. In conclusion, a cutoff value for (99m)Tc-pertechnetate uptake of 1.0% was useful to discriminate between Graves' disease and painless thyroiditis.

  8. Wall Street som kreationistisk forkynder

    DEFF Research Database (Denmark)

    Ekman, Susanne

    2016-01-01

    Artiklen gennemgår Karen Hos etnografi om Wall Street: "Liquidated: An ethnography of Wall Street" set i lyset af den offentlige debat vedrørende Goldman Sachs opkøb af Dong......Artiklen gennemgår Karen Hos etnografi om Wall Street: "Liquidated: An ethnography of Wall Street" set i lyset af den offentlige debat vedrørende Goldman Sachs opkøb af Dong...

  9. Predictive capacity of a non-radioisotopic local lymph node assay using flow cytometry, LLNA:BrdU-FCM: Comparison of a cutoff approach and inferential statistics.

    Science.gov (United States)

    Kim, Da-Eun; Yang, Hyeri; Jang, Won-Hee; Jung, Kyoung-Mi; Park, Miyoung; Choi, Jin Kyu; Jung, Mi-Sook; Jeon, Eun-Young; Heo, Yong; Yeo, Kyung-Wook; Jo, Ji-Hoon; Park, Jung Eun; Sohn, Soo Jung; Kim, Tae Sung; Ahn, Il Young; Jeong, Tae-Cheon; Lim, Kyung-Min; Bae, SeungJin

    2016-01-01

    In order for a novel test method to be applied for regulatory purposes, its reliability and relevance, i.e., reproducibility and predictive capacity, must be demonstrated. Here, we examine the predictive capacity of a novel non-radioisotopic local lymph node assay, LLNA:BrdU-FCM (5-bromo-2'-deoxyuridine-flow cytometry), with a cutoff approach and inferential statistics as a prediction model. 22 reference substances in OECD TG429 were tested with a concurrent positive control, hexylcinnamaldehyde 25%(PC), and the stimulation index (SI) representing the fold increase in lymph node cells over the vehicle control was obtained. The optimal cutoff SI (2.7≤cutoff <3.5), with respect to predictive capacity, was obtained by a receiver operating characteristic curve, which produced 90.9% accuracy for the 22 substances. To address the inter-test variability in responsiveness, SI values standardized with PC were employed to obtain the optimal percentage cutoff (42.6≤cutoff <57.3% of PC), which produced 86.4% accuracy. A test substance may be diagnosed as a sensitizer if a statistically significant increase in SI is elicited. The parametric one-sided t-test and non-parametric Wilcoxon rank-sum test produced 77.3% accuracy. Similarly, a test substance could be defined as a sensitizer if the SI means of the vehicle control, and of the low, middle, and high concentrations were statistically significantly different, which was tested using ANOVA or Kruskal-Wallis, with post hoc analysis, Dunnett, or DSCF (Dwass-Steel-Critchlow-Fligner), respectively, depending on the equal variance test, producing 81.8% accuracy. The absolute SI-based cutoff approach produced the best predictive capacity, however the discordant decisions between prediction models need to be examined further. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Suggested cut-off values for vitamin D as a risk marker for total and cardiac death in patients with suspected acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Patrycja Anna Naesgaard

    2016-02-01

    Full Text Available Background: Several studies have demonstrated an association between low vitamin D levels and cardiovascular risk. Vitamin D cut off levels are still under debate. Objectives: To assess two cut-off levels, 40 nmol/L and 70 nmol/L, respectively, for vitamin D measured as 25-hydroxyvitamin D [25(OHD] in chest pain patients with suspected acute coronary syndrome.Methods: We investigated 1853 patients from coastal-Norway and inland Northern-Argentina. A similar database was used for pooling of data. 2-year follow-up data including all-cause mortality, cardiac death and sudden cardiac death in the total patient population were analyzed, applying univariate and multivariable analysis. Results: 255 patients with known vitamin D concentrations died. In the multivariable analysis, there was a decrease in total mortality above a cut-off level of 40 nmol/L and a decrease in cardiac death above a cut-off level of 70 nmol/L, [HRs of 0.66 (95% CI, 0.50 – 0.88, p = 0.004 and 0.46 (95% CI, 0.22 – 0.94, p = 0.034, respectively].Conclusion: Vitamin D cut-off levels of 40 nmol/L and 70 nmol/L, were related to total mortality and cardiac death, respectively.

  11. Observations on resistive wall modes

    International Nuclear Information System (INIS)

    Gerwin, R.A.; Finn, J.M.

    1996-01-01

    Several results on resistive wall modes and their application to tokamaks are presented. First, it is observed that in the presence of collisional parallel dynamics there is an exact cancellation to lowest order of the dissipative and sound wave effects for an ideal Ohm's law. This is easily traced to the fact that the parallel dynamics occurs along the perturbed magnetic field lines for such electromagnetic modes. Such a cancellation does not occur in the resistive layer of a tearing-like mode. The relevance to models for resistive wall modes using an electrostatic Hammett-Perkins type operator to model Landau damping will be discussed. Second, we observe that with an ideal Ohm's law, resistive wall modes can be destabilized by rotation in that part of parameter space in which the ideal MHD modes are stable with the wall at infinity. This effect can easily be explained by interpreting the resistive wall instability in terms of mode coupling between the backward stable MHD mode and a stable mode locked into the wall. Such an effect can occur for very small rotation for tearing-resistive wall modes in which inertia dominates viscosity in the layer, but the mode is stabilized by further rotation. For modes for which viscosity dominates in the layer, rotation is purely stabilizing. For both tearing models, a somewhat higher rotation frequency gives stability essentially whenever the tearing mode is stable with a perfectly conducting wall. These tearing/resistive wall results axe also simply explained in terms of mode coupling. It has been shown that resonant external ideal modes can be stabilized in the presence of resistive wall and resistive plasma with rotation of order the nominal tearing mode growth rate. We show that these modes behave as resistive wall tearing modes in the sense above. This strengthens the suggestion that rotational stabilization of the external kink with a resistive wall is due to the presence of resistive layers, even for ideal modes

  12. The analytic regularization ζ function method and the cut-off method in Casimir effect

    International Nuclear Information System (INIS)

    Svaiter, N.F.; Svaiter, B.F.

    1990-01-01

    The zero point energy associated to a hermitian massless scalar field in the presence of perfectly reflecting plates in a three dimensional flat space-time is discussed. A new technique to unify two different methods - the ζ function and a variant of the cut-off method - used to obtain the so called Casimir energy is presented, and the proof of the analytic equivalence between both methods is given. (author)

  13. Supersymmetric domain walls

    NARCIS (Netherlands)

    Bergshoeff, Eric A.; Kleinschmidt, Axel; Riccioni, Fabio

    2012-01-01

    We classify the half-supersymmetric "domain walls," i.e., branes of codimension one, in toroidally compactified IIA/IIB string theory and show to which gauged supergravity theory each of these domain walls belong. We use as input the requirement of supersymmetric Wess-Zumino terms, the properties of

  14. The Prevalence of Nocturia and Nocturnal Polyuria: Can New Cutoff Values Be Suggested According to Age and Sex?

    Science.gov (United States)

    2016-01-01

    Purpose The aims of this study were to assess the prevalence of nocturia and nocturnal polyuria (NP) and to define new cutoff values according to age and sex for both conditions. Methods Data from a population-based prevalence survey conducted among a random sample of 2,128 adults were analyzed in this study. Participants were requested to fill out a questionnaire including the International Continence Society (ICS) definitions of lower urinary tract symptoms and the International Consultation on Incontinence Questionnaire - Short Form. Additionally, a 1-day bladder diary was given to each individual. The participants were divided into 5 age groups. The prevalence of nocturia was calculated based on definitions of nocturia as ≥1 voiding episodes, ≥2 episodes, and ≥3 episodes. NP was evaluated according to the ICS definition. The mean±standard errors and 95th percentile values were calculated in each group as new cutoff values for NP. Results The prevalence of nocturia was estimated as 28.4%, 17.6%, and 8.9% for ≥1, ≥2, and ≥3 voiding episodes each night, respectively. When nocturia was defined as 2 or more voiding episodes at night, the prevalence decreased significantly. The mean NP index was 29.4%±15.0% in men and 23.1%±11.8% in women. For the age groups of <50 years, 50–59 years, and ≥60 years, the new cutoff values for the diagnosis of NP were calculated as 48%, 69%, and 59% for men and 41%, 50%, and 42% for women, respectively. Conclusions We found that the definition of nocturia was still controversial and that waking up once for voiding might be within the normal spectrum of behavior. The definition of NP should be modified, and new cutoff values should be defined using the data presented in our study and in other forthcoming studies. PMID:28043108

  15. An optimal cut-off point for the calving interval may be used as an indicator of bovine abortions.

    Science.gov (United States)

    Bronner, Anne; Morignat, Eric; Gay, Emilie; Calavas, Didier

    2015-10-01

    The bovine abortion surveillance system in France aims to detect as early as possible any resurgence of bovine brucellosis, a disease of which the country has been declared free since 2005. It relies on the mandatory notification and testing of each aborting cow, but under-reporting is high. This research uses a new and simple approach which considers the calving interval (CI) as a "diagnostic test" to determine optimal cut-off point c and estimate diagnostic performance of the CI to identify aborting cows, and herds with multiple abortions (i.e. three or more aborting cows per calving season). The period between two artificial inseminations (AI) was considered as a "gold standard". During the 2006-2010 calving seasons, the mean optimal CI cut-off point for identifying aborting cows was 691 days for dairy cows and 703 days for beef cows. Depending on the calving season, production type and scale at which c was computed (individual or herd), the average sensitivity of the CI varied from 42.6% to 64.4%; its average specificity from 96.7% to 99.7%; its average positive predictive value from 27.6% to 65.4%; and its average negative predictive value from 98.7% to 99.8%. When applied to the French bovine population as a whole, this indicator identified 2-3% of cows suspected to have aborted, and 10-15% of herds suspected of multiple abortions. The optimal cut-off point and CI performance were consistent over calving seasons. By applying an optimal CI cut-off point to the cattle demographics database, it becomes possible to identify herds with multiple abortions, carry out retrospective investigations to find the cause of these abortions and monitor a posteriori compliance of farmers with their obligation to report abortions for brucellosis surveillance needs. Therefore, the CI could be used as an indicator of abortions to help improve the current mandatory notification surveillance system. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Abdominal wall blocks in adults

    DEFF Research Database (Denmark)

    Børglum, Jens; Gögenür, Ismail; Bendtsen, Thomas F

    2016-01-01

    been introduced with success. Future research should also investigate the effect of specific abdominal wall blocks on neuroendocrine and inflammatory stress response after surgery.  Summary USG abdominal wall blocks in adults are commonplace techniques today. Most abdominal wall blocks are assigned......Purpose of review Abdominal wall blocks in adults have evolved much during the last decade; that is, particularly with the introduction of ultrasound-guided (USG) blocks. This review highlights recent advances of block techniques within this field and proposes directions for future research.......  Recent findings Ultrasound guidance is now considered the golden standard for abdominal wall blocks in adults, even though some landmark-based blocks are still being investigated. The efficiency of USG transversus abdominis plane blocks in relation to many surgical procedures involving the abdominal wall...

  17. {sup 3}He spectrum at small atmospheric depths for different geomagnetic cutoff values

    Energy Technology Data Exchange (ETDEWEB)

    Papini, P. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Grimani, C. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); Stephens, S.A. [Tata Institute of Fundamental Research, Bombay (International Commission on Radiation Units and Measurements)

    1995-09-01

    It is carried out a calculation to determine the energy spectra of secondary {sup 3}He at small atmospheric depths. It is produced in the spallation reaction of primary helium and heavier nuclei in the overlying atmosphere. It is examined the effect of the geomagnetic cut-off on the spectral shape of the secondary {sup 3}He nuclei. The calculations are being carried out for both solar minimum and maximum periods. Results from these calculations will be presented at the Conference.

  18. Development and validation of optimal cut-off value in inter-arm systolic blood pressure difference for prediction of cardiovascular events.

    Science.gov (United States)

    Hirono, Akira; Kusunose, Kenya; Kageyama, Norihito; Sumitomo, Masayuki; Abe, Masahiro; Fujinaga, Hiroyuki; Sata, Masataka

    2018-01-01

    An inter-arm systolic blood pressure difference (IAD) is associated with cardiovascular disease. The aim of this study was to develop and validate the optimal cut-off value of IAD as a predictor of major adverse cardiac events in patients with arteriosclerosis risk factors. From 2009 to 2014, 1076 patients who had at least one cardiovascular risk factor were included in the analysis. We defined 700 randomly selected patients as a development cohort to confirm that IAD was the predictor of cardiovascular events and to determine optimal cut-off value of IAD. Next, we validated outcomes in the remaining 376 patients as a validation cohort. The blood pressure (BP) of both arms measurements were done simultaneously using the ankle-brachial blood pressure index (ABI) form of automatic device. The primary endpoint was the cardiovascular event and secondary endpoint was the all-cause mortality. During a median period of 2.8 years, 143 patients reached the primary endpoint in the development cohort. In the multivariate Cox proportional hazards analysis, IAD was the strong predictor of cardiovascular events (hazard ratio: 1.03, 95% confidence interval: 1.01-1.05, p=0.005). The receiver operating characteristic curve revealed that 5mmHg was the optimal cut-off point of IAD to predict cardiovascular events (p<0.001). In the validation cohort, the presence of a large IAD (IAD ≥5mmHg) was significantly associated with the primary endpoint (p=0.021). IAD is significantly associated with future cardiovascular events in patients with arteriosclerosis risk factors. The optimal cut-off value of IAD is 5mmHg. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  19. Establishing ultrasound based transient elastography cutoffs for different stages of hepatic fibrosis and cirrhosis in Egyptian chronic hepatitis C patients.

    Science.gov (United States)

    Elsharkawy, Aisha; Alboraie, Mohamed; Fouad, Rabab; Asem, Noha; Abdo, Mahmoud; Elmakhzangy, Hesham; Mehrez, Mai; Khattab, Hany; Esmat, Gamal

    2017-12-01

    Transient elastography is widely used to assess fibrosis stage in chronic hepatitis C (CHC). We aimed to establish and validate different transient elastography cut-off values for significant fibrosis and cirrhosis in CHC genotype 4 patients. The data of 100 treatment-naive CHC patients (training set) and 652 patients (validation set) were analysed. The patients were subjected to routine pretreatment laboratory investigations, liver biopsy and histopathological staging of hepatic fibrosis according to the METAVIR scoring system. Transient elastography was performed before and in the same week as liver biopsy using FibroScan (Echosens, Paris, France). Transient elastography results were correlated to different stages of hepatic fibrosis in both the training and validation sets. ROC curves were constructed. In the training set, the best transient elastography cut-off values for significant hepatic fibrosis (≥F2 METAVIR), advanced hepatic fibrosis (≥F3 METAVIR) and cirrhosis (F4 METAVIR) were 7.1, 9 and 12.2 kPa, with sensitivities of 87%, 87.5% and 90.9% and specificities of 100%, 99.9% and 99.9%, respectively. The application of these cut-offs in the validation set showed sensitivities of 85.5%, 82.8% and 92% and specificities of 86%, 89.4% and 99.01% for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, respectively. Transient elastography performs well for significant hepatic fibrosis, advanced hepatic fibrosis and cirrhosis, with validated cut-offs of 7.1, 9 and 12.2 kPa, respectively, in genotype 4 CHC patients. Copyright © 2017 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.

  20. Log-layer mismatch and modeling of the fluctuating wall stress in wall-modeled large-eddy simulations

    Science.gov (United States)

    Yang, Xiang I. A.; Park, George Ilhwan; Moin, Parviz

    2017-10-01

    Log-layer mismatch refers to a chronic problem found in wall-modeled large-eddy simulation (WMLES) or detached-eddy simulation, where the modeled wall-shear stress deviates from the true one by approximately 15 % . Many efforts have been made to resolve this mismatch. The often-used fixes, which are generally ad hoc, include modifying subgrid-scale stress models, adding a stochastic forcing, and moving the LES-wall-model matching location away from the wall. An analysis motivated by the integral wall-model formalism suggests that log-layer mismatch is resolved by the built-in physics-based temporal filtering. In this work we investigate in detail the effects of local filtering on log-layer mismatch. We show that both local temporal filtering and local wall-parallel filtering resolve log-layer mismatch without moving the LES-wall-model matching location away from the wall. Additionally, we look into the momentum balance in the near-wall region to provide an alternative explanation of how LLM occurs, which does not necessarily rely on the numerical-error argument. While filtering resolves log-layer mismatch, the quality of the wall-shear stress fluctuations predicted by WMLES does not improve with our remedy. The wall-shear stress fluctuations are highly underpredicted due to the implied use of LES filtering. However, good agreement can be found when the WMLES data are compared to the direct numerical simulation data filtered at the corresponding WMLES resolutions.

  1. Cut-Offs and Response Criteria for the Hospital Universitario La Princesa Index (HUPI and Their Comparison to Widely-Used Indices of Disease Activity in Rheumatoid Arthritis.

    Directory of Open Access Journals (Sweden)

    Isidoro González-Álvaro

    Full Text Available To estimate cut-off points and to establish response criteria for the Hospital Universitario La Princesa Index (HUPI in patients with chronic polyarthritis.Two cohorts, one of early arthritis (Princesa Early Arthritis Register Longitudinal [PEARL] study and other of long-term rheumatoid arthritis (Estudio de la Morbilidad y Expresión Clínica de la Artritis Reumatoide [EMECAR] including altogether 1200 patients were used to determine cut-off values for remission, and for low, moderate and high activity through receiver operating curve (ROC analysis. The areas under ROC (AUC were compared to those of validated indexes (SDAI, CDAI, DAS28. ROC analysis was also applied to establish minimal and relevant clinical improvement for HUPI.The best cut-off points for HUPI are 2, 5 and 9, classifying RA activity as remission if ≤2, low disease activity if >2 and ≤5, moderate if >5 and <9 and high if ≥9. HUPI's AUC to discriminate between low-moderate activity was 0.909 and between moderate-high activity 0.887. DAS28's AUCs were 0.887 and 0.846, respectively; both indices had higher accuracy than SDAI (AUCs: 0.832 and 0.756 and CDAI (AUCs: 0.789 and 0.728. HUPI discriminates remission better than DAS28-ESR in early arthritis, but similarly to SDAI. The HUPI cut-off for minimal clinical improvement was established at 2 and for relevant clinical improvement at 4. Response criteria were established based on these cut-off values.The cut-offs proposed for HUPI perform adequately in patients with either early or long term arthritis.

  2. Cut-Offs and Response Criteria for the Hospital Universitario La Princesa Index (HUPI) and Their Comparison to Widely-Used Indices of Disease Activity in Rheumatoid Arthritis.

    Science.gov (United States)

    González-Álvaro, Isidoro; Castrejón, Isabel; Ortiz, Ana M; Toledano, Esther; Castañeda, Santos; García-Vadillo, Alberto; Carmona, Loreto

    2016-01-01

    To estimate cut-off points and to establish response criteria for the Hospital Universitario La Princesa Index (HUPI) in patients with chronic polyarthritis. Two cohorts, one of early arthritis (Princesa Early Arthritis Register Longitudinal [PEARL] study) and other of long-term rheumatoid arthritis (Estudio de la Morbilidad y Expresión Clínica de la Artritis Reumatoide [EMECAR]) including altogether 1200 patients were used to determine cut-off values for remission, and for low, moderate and high activity through receiver operating curve (ROC) analysis. The areas under ROC (AUC) were compared to those of validated indexes (SDAI, CDAI, DAS28). ROC analysis was also applied to establish minimal and relevant clinical improvement for HUPI. The best cut-off points for HUPI are 2, 5 and 9, classifying RA activity as remission if ≤2, low disease activity if >2 and ≤5), moderate if >5 and <9 and high if ≥9. HUPI's AUC to discriminate between low-moderate activity was 0.909 and between moderate-high activity 0.887. DAS28's AUCs were 0.887 and 0.846, respectively; both indices had higher accuracy than SDAI (AUCs: 0.832 and 0.756) and CDAI (AUCs: 0.789 and 0.728). HUPI discriminates remission better than DAS28-ESR in early arthritis, but similarly to SDAI. The HUPI cut-off for minimal clinical improvement was established at 2 and for relevant clinical improvement at 4. Response criteria were established based on these cut-off values. The cut-offs proposed for HUPI perform adequately in patients with either early or long term arthritis.

  3. Science and art of setting performance standards and cutoff scores in kinesiology.

    Science.gov (United States)

    Zhu, Weimo

    2013-12-01

    Setting standards and cutoff scores is essential to any measurement and evaluation practice. Two evaluation frameworks, norm-referenced (NR) and criterion-referenced (CR), have often been used for setting standards. Although setting fitness standards based on the NR evaluation is relatively easy as long as a nationally representative sample can be obtained and regularly updated, it has several limitations-namely, time dependency, population dependence, discouraging low-level performers, and favoring advantaged or punishing disadvantaged individuals. Fortunately, these limitations can be significantly eliminated by employing the CR evaluation, which was introduced to kinesiology by Safrit and colleagues in the 1980s and has been successfully applied to some practical problems (e.g., set health-related fitness standards for FITNESSGRAM). Yet, the CR evaluation has its own challenges, e.g., selecting an appropriate measure for a criterion behavior, when the expected relationship between the criterion behavior and a predictive measure is not clear, and when standards are not consistent among multiple field measures. Some of these challenges can be addressed by employing the latest statistical methods (e.g., test equating). This article provides a comprehensive review of the science and art of setting standards and cutoff scores in kinesiology. After a brief historical overview of the standard-setting practice in kinesiology is presented, a case analysis of a successful CR evaluation, along with related challenges, is described. Lessons learned from past and current practice as well as how to develop a defendable standard are described. Finally, future research needs and directions are outlined.

  4. Topological domain walls in helimagnets

    Science.gov (United States)

    Schoenherr, P.; Müller, J.; Köhler, L.; Rosch, A.; Kanazawa, N.; Tokura, Y.; Garst, M.; Meier, D.

    2018-05-01

    Domain walls naturally arise whenever a symmetry is spontaneously broken. They interconnect regions with different realizations of the broken symmetry, promoting structure formation from cosmological length scales to the atomic level1,2. In ferroelectric and ferromagnetic materials, domain walls with unique functionalities emerge, holding great promise for nanoelectronics and spintronics applications3-5. These walls are usually of Ising, Bloch or Néel type and separate homogeneously ordered domains. Here we demonstrate that a wide variety of new domain walls occurs in the presence of spatially modulated domain states. Using magnetic force microscopy and micromagnetic simulations, we show three fundamental classes of domain walls to arise in the near-room-temperature helimagnet iron germanium. In contrast to conventional ferroics, the domain walls exhibit a well-defined inner structure, which—analogous to cholesteric liquid crystals—consists of topological disclination and dislocation defects. Similar to the magnetic skyrmions that form in the same material6,7, the domain walls can carry a finite topological charge, permitting an efficient coupling to spin currents and contributions to a topological Hall effect. Our study establishes a new family of magnetic nano-objects with non-trivial topology, opening the door to innovative device concepts based on helimagnetic domain walls.

  5. Defining the optimal cut-off values for liver enzymes in diagnosing blunt liver injury.

    Science.gov (United States)

    Koyama, Tomohide; Hamada, Hirohisa; Nishida, Masamichi; Naess, Paal A; Gaarder, Christine; Sakamoto, Tetsuya

    2016-01-25

    Patients with blunt trauma to the liver have elevated levels of liver enzymes within a short time post injury, potentially useful in screening patients for computed tomography (CT). This study was performed to define the optimal cut-off values for serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in patients with blunt liver injury diagnosed with contrast enhanced multi detector-row CT (CE-MDCT). All patients admitted from May 2006 to July 2013 to Teikyo University Hospital Trauma and Critical Care Center, and who underwent abdominal CE-MDCT within 3 h after blunt trauma, were retrospectively enrolled. Using receiver operating characteristic (ROC) curve analysis, the optimal cut-off values for AST and ALT were defined, and sensitivity and specificity were calculated. Of a total of 676 blunt trauma patients 64 patients were diagnosed with liver injury (Group LI+) and 612 patients without liver injury (Group LI-). Group LI+ and LI- were comparable for age, Revised Trauma Score, and Probability of survival. The groups differed in Injury Severity Score [median 21 (interquartile range 9-33) vs. 17 (9-26) (p tool for CT scan in patients otherwise eligible for observation only or as a transfer criterion to a facility with CT scan capability.

  6. Age-related cutoffs for cervical movement behaviour to distinguish chronic idiopathic neck pain patients from unimpaired subjects.

    Science.gov (United States)

    Niederer, Daniel; Vogt, Lutz; Wilke, Jan; Rickert, Marcus; Banzer, Winfried

    2015-03-01

    The present study aims to develop age-dependent cutoff values in a quasi-experimental, cross-sectional diagnostic test study. One hundred and twenty (120) asymptomatic subjects (n = 100, 36♀, 18 75 years, for normative values; n = 20, 23-75 years, 15♀, for selectivity analyses) and 20 patients suffering from idiopathic neck pain (selectivity analyses, 22-71 years, 15♀) were included. Subjects performed five repetitive maximal cervical flexion/extension movements in an upright sitting position. Cervical kinematic characteristics (maximal range of motion (ROM), coefficient of variation (CV) and mean conjunct movements in rotation and flexion (CM)) were calculated from raw 3D ultrasonic data. Regression analyses were conducted to reveal associations between kinematic characteristics and age and gender and thus to determine normative values for healthy subjects. Age explains 53 % of the variance in ROM (decrease 10.2° per decade), 13 % in CV (increase 0.003 per decade) and 9 % in CM (increase 0.57° per decade). Receivers operating characteristic (ROC) analyses were conducted for differences between individual values of the kinematic characteristics and normative values to optimise cutoff values for distinguishing patients from unimpaired subjects (20 patients and 20 healthy). Cutoff values distinguished asymptomatic subjects' and chronic nonspecific neck patient's movement characteristics with sufficient quality (sensitivity 70-80 %, specificity 65-70 %). By including such classifications, the present findings expand actual research stating an age-related decrease in kinematic behaviour only using categorising span widths across decades. Future study is warranted to reveal our results' potential applicability for intervention onset decision making for idiopathic neck pain patients.

  7. Prediction of wall shear stresses in transitional boundary layers using near-wall mean velocity profiles

    International Nuclear Information System (INIS)

    Jeon, Woo Pyung; Shin, Sung Ho; Kang, Shin Hyoung

    2000-01-01

    The local wall shear stress in transitional boundary layer was estimated from the near-wall mean velocity data using the principle of Computational Preston tube Method(CPM). The previous DNS and experimental databases of transitional boundary layers were used to demonstrate the accuracy of the method and to provide the applicable range of wall unit y + . The skin friction coefficients predicted by the CPM agreed well with those from previous studies. To reexamine the applicability of the CPM, near-wall hot-wire measurements were conducted in developing transitional boundary layers on a flat plate with different freestream turbulence intensities. The intermittency profiles across the transitional boundary layers were reasonably obtained from the conditional sampling technique. An empirical correlation between the representative intermittency near the wall and the free parameter K 1 of the extended wall function of CPM has been newly proposed using the present and other experimental data. The CPM has been verified as a useful tool to measure the wall shear stress in transitional boundary layer with reasonable accuracy

  8. Hot wire production of single-wall and multi-wall carbon nanotubes

    Science.gov (United States)

    Dillon, Anne C.; Mahan, Archie H.; Alleman, Jeffrey L.

    2010-10-26

    Apparatus (210) for producing a multi-wall carbon nanotube (213) may comprise a process chamber (216), a furnace (217) operatively associated with the process chamber (216), and at least one filament (218) positioned within the process chamber (216). At least one power supply (220) operatively associated with the at least one filament (218) heats the at least one filament (218) to a process temperature. A gaseous carbon precursor material (214) operatively associated with the process chamber (216) provides carbon for forming the multi-wall carbon nanotube (213). A metal catalyst material (224) operatively associated with the process (216) catalyzes the formation of the multi-wall carbon nanotube (213).

  9. Implementing Green Walls in Schools.

    Science.gov (United States)

    McCullough, Michael B; Martin, Michael D; Sajady, Mollika A

    2018-01-01

    Numerous studies in applied pedagogical design have shown that, at all educational levels, direct exposure to the natural environment can enhance learning by improving student attention and behaviors. Implementing green walls-a "vertical garden," or "living wall" interior wall that typically includes greenery, a growing medium (soil or substrate) and a water delivery system-provides environmental health benefits, but also provides a practical application within classrooms for minimizing directed attention fatigue in students by connecting them to "outdoor nature" within the indoor environment. Hands-on "project-based" learning is another pedagogical strategy that has proved to be effective across the spectrum of educational levels and across subject areas. Green walls have the potential to inspire critical thinking through a combination of project-based learning strategies and environmental education. The authors have outlined a curriculum involving the implementation of an indoor living wall system within a classroom-learning environment, incorporating project-based learning modules that interact with the wall. In conjunction with the passive health benefits of a green wall, project-based curriculum models can connect students interactively with indoor nature and have the potential to inspire real-world thinking related to science, technology, engineering, art, and mathematics fields within the indoor learning environment. Through a combination of these passive and interactive modes, students are connected to nature in the indoor environment regardless of weather conditions outdoors. Future research direction could include post-construction studies of the effectiveness of project-based curricula related to living walls, and the long-term impacts of implementing green walls in classrooms on school achievement and student behaviors.

  10. Cut-off scaling of high-harmonic generation driven by a femtosecond visible optical parametric amplifier

    International Nuclear Information System (INIS)

    Cirmi, Giovanni; Lai, Chien-Jen; Granados, Eduardo; Huang, Shu-Wei; Sell, Alexander; Hong, Kyung-Han; Moses, Jeffrey; Keathley, Phillip; Kärtner, Franz X

    2012-01-01

    We studied high-harmonic generation (HHG) in Ar, Ne and He gas jets using a broadly tunable, high-energy optical parametric amplifier (OPA) in the visible wavelength range. We optimized the noncollinear OPA to deliver tunable, femtosecond pulses with 200-500 µJ energy at the 1 kHz repetition rate with excellent spatiotemporal properties, suitable for HHG experiments. By tuning the central wavelength of the OPA while keeping other parameters (energy, duration and beam size) constant, we experimentally studied the scaling law of cut-off energy with the driver wavelength in helium. Our measurements show a λ 1.7+0.2 dependence of the HHG cut-off photon energy over the full visible range in agreement with previous experiments of near- and mid-IR wavelengths. By tuning the central wavelength of the driver source, the high-order harmonic spectra in the extreme ultraviolet cover the full range of photon energy between ∼25 and ∼100 eV. Due to the high coherence intrinsic in HHG, as well as the broad and continuous tunability in the extreme UV range, a high energy, high repetition rate version of this source might be an ideal seed for free electron lasers.

  11. Anisotropy of domain wall resistance

    Science.gov (United States)

    Viret; Samson; Warin; Marty; Ott; Sondergard; Klein; Fermon

    2000-10-30

    The resistive effect of domain walls in FePd films with perpendicular anisotropy was studied experimentally as a function of field and temperature. The films were grown directly on MgO substrates, which induces an unusual virgin magnetic configuration composed of 60 nm wide parallel stripe domains. This allowed us to carry out the first measurements of the anisotropy of domain wall resistivity in the two configurations of current perpendicular and parallel to the walls. At 18 K, we find 8.2% and 1.3% for the domain wall magnetoresistance normalized to the wall width (8 nm) in these two respective configurations. These values are consistent with the predictions of Levy and Zhang.

  12. Risk Assessment of Abdominal Wall Thickness Measured on Pre-Operative Computerized Tomography for Incisional Surgical Site Infection after Abdominal Surgery.

    Science.gov (United States)

    Tongyoo, Assanee; Chatthamrak, Putipan; Sriussadaporn, Ekkapak; Limpavitayaporn, Palin; Mingmalairak, Chatchai

    2015-07-01

    The surgical site infection (SSI) is a common complication of abdominal operation. It relates to increased hospital stay, increased healthcare cost, and decreased patient's quality of life. Obesity, usually defined by BMI, is known as one of the risks of SSI. However, the thickness of subcutaneous layers of abdominal wall might be an important local factor affecting the rate of SSI after the abdominal operations. The objective of this study is to assess the importance of the abdominal wall thickness on incisional SSI rate. The subjects of the present study were patients who had undergone major abdominal operations at Thammasat University Hospital between June 2013 and May 2014, and had been investigated with CT scans before their operations. The demographic data and clinical information of these patients were recorded. The thickness ofsubcutaneous fatty tissue from skin down to the most superficial layer of abdominal wall muscle at the surgical site was measured on CT images. The wound infectious complication was reviewed and categorized as superficial and deep incisional SSIfollowing the definition from Centersfor Disease Control and Prevention (CDC) guidelines. The significance ofeach potentialfactors on SSI rates was determined separately with student t-test for quantitative data and χ2-test for categorical data. Then all factors, which had p operative CTscans. Post-operative SSI was 25.2% (35/139), superficial and deep types in 27 and 8 patients, respectively. The comparison of abdominal wall thickness between patients with and without infection was significantly different (20.0 ± 8.4 mm and 16.0 ± 7.2 mm, respectively). When the thickness at 20 mm was used as the cut-off value, 43 of 139 patients had abdominal wall thickness ≥ 20 mm. The incidence of SSI of the thickness ±20 mm group was 37.2% (16/43) and of the less thickness group was 19.8% (19/96), with p operation. However, only abdominal wall thickness and wound classification were still significant

  13. Shielding wall for thermonuclear device

    International Nuclear Information System (INIS)

    Uchida, Takaho.

    1989-01-01

    This invention concerns shielding walls opposing to plasmas of a thermonuclear device and it is an object thereof to conduct reactor operation with no troubles even if a portion of shielding wall tiles should be damaged. That is, the shielding wall tiles are constituted as a dual layer structure in which the lower base tiles are connected by means of bolts to first walls. Further, the upper surface tiles are bolt-connected to the layer base tiles. In this structure, the plasma thermal loads are directly received by the surface layer tiles and heat is conducted by means of conduction and radiation to the underlying base tiles and the first walls. Even upon occurrence of destruction accidents to the surface layer tiles caused by incident heat or electromagnetic force upon elimination of plasmas, since the underlying base tiles remain as they are, the first walls constituted with stainless steels, etc. are not directly exposed to the plasmas. Accordingly, the integrity of the first walls having cooling channels can be maintained and sputtering intrusion of atoms of high atom number into the plasmas can be prevented. (I.S.)

  14. KETERASINGAN DALAM FILM WALL-E

    Directory of Open Access Journals (Sweden)

    Rahmadya Putra Nugraha

    2017-05-01

    Full Text Available Modern society nowadays technological advances at first create efficiency in human life. Further development of the technology thus drown human in a routine and automation of work created. The State is to be one of the causes of man separated from fellow or the outside world and eventually experiencing alienation. The movie as a mass media function to obtain the movie and entertainment can be informative or educative function is contained, even persuasive. The purpose of this research was conducted to find out the alienation in the movie Wall E. The concepts used to analyze the movie Wall E this is communication, movie, and alienation. The concept of alienation of human alienation from covering its own products of human alienation from its activities, the human alienation from nature of his humanity and human alienation from each other. Paradigm used is a critical paradigm with type a descriptive research with qualitative approach. The method used is the analysis of semiotics Roland Barthes to interpretation the scope of social alienation and fellow humans in the movie.This writing research results found that alienation of humans with other humans influenced the development of the technology and how the human it self represented of technology, not from our fellow human beings. Masyarakat modern saat ini kemajuan teknologi pada awalnya membuat efisiensi dalam kehidupan manusia. Perkembangan selanjutnya teknologi justru menenggelamkan manusia dalam suatu rutinitas dan otomatisasi kerja yang diciptakan. Keadaan itulah yang menjadi salah satu penyebab manusia terpisah dari sesama atau dunia luar dan akhirnya mengalami keterasingan. Film sebagai media massa berfungsi untuk memperoleh hiburan dan dalam film dapat terkandung fungsi informatif maupun edukatif, bahkan persuasif. Tujuan Penelitian ini dilakukan untuk mengetahui Keterasingan dalam film Wall E. Konsep-konsep yang digunakan untuk menganalisis film Wall E ini adalah komunikasi, film, dan

  15. Cutoff score of the sexual interest and desire inventory-female for diagnosis of hypoactive sexual desire disorder

    NARCIS (Netherlands)

    Clayton, Anita H.; Segraves, Robert T.; Bakish, David; Goldmeier, David; Tignol, Jean; van Lunsen, Rik H. W.; Nappi, Rossella E.; Wunderlich, Glen; Kimura, Toshio; Lewis-D'Agostino, Diane J.; Pyke, Robert

    2010-01-01

    To determine the most appropriate cutoff value for the Sexual Interest and Desire Inventory-Female (SIDI-F) score to discriminate between women with hypoactive sexual desire disorder (HSDD) and those with no female sexual dysfunction (FSD). The SIDI-F is a clinician-rated instrument consisting of 13

  16. Physical Activity Questionnaire for children and adolescents: English norms and cut-off points.

    Science.gov (United States)

    Voss, Christine; Ogunleye, Ayodele A; Sandercock, Gavin R H

    2013-08-01

    The Physical Activity Questionnaire for Children and Adolescents (PAQ-C/-A) provides general estimates of physical activity levels. Following recent expert recommendations for using the PAQ for population surveillance, the aim of this paper was twofold: first, to describe normative PAQ data for English youth; and second, to determine a criterion-referenced PAQ-score cut-off point. Participants (n = 7226, 53% boys, 10-15 years) completed an anglicized version of the PAQ. Peak oxygen uptake (VO2peak ) was predicted from PACER lap count according to latest FITNESSGRAM standards and categorized into "at-risk" and "no-risk" for metabolic syndrome. ROC curves were drawn for each age-sex group to identify PAQ scores, which categorized youth into "sufficiently active" versus "low-active" groups, using cardiorespiratory fitness as the criterion-referenced standard. PAQ scores were higher in boys than in girls and declined with age. Mean PAQ score was a significant, albeit relatively weak (area under the curve PAQ scores of ≥2.9 for boys and ≥2.7 for girls were identified as cut-off points, although it may be more appropriate to use lower, age-specific PAQ scores for girls of 13, 14 and 15 years (2.6, 2.4, 2.3, respectively). The normative and criterion-referenced PAQ values may be used to standardize and categorize PAQ scores in future youth population studies. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  17. Association Mapping of Cell Wall Synthesis Regulatory Genes and Cell Wall Quality in Switchgrass

    Energy Technology Data Exchange (ETDEWEB)

    Bartley, Laura [Univ. of Oklahoma, Norman, OK (United States). Dept. of Microbiology and Plant Biology; Wu, Y. [Oklahoma State Univ., Stillwater, OK (United States); Zhu, L. [Oklahoma State Univ., Stillwater, OK (United States); Brummer, E. C. [Noble Foundation, Ardmore, OK (United States); Saha, M. [Noble Foundation, Ardmore, OK (United States)

    2016-05-31

    Inefficient conversion of biomass to biofuels is one of the main barriers for biofuel production from such materials. Approximately half of polysaccharides in biomass remain unused by typical biochemical conversion methods. Conversion efficiency is influenced by the composition and structure of cell walls of biomass. Grasses such as wheat, maize, and rice, as well as dedicated perennial bioenergy crops, like switchgrass, make up ~55% of biomass that can be produced in the United States. Grass cell walls have a different composition and patterning compared with dicotyledonous plants, including the well-studied model plant, Arabidopsis. This project identified genetic determinants of cell wall composition in grasses using both naturally occurring genetic variation of switchgrass and gene network reconstruction and functional assays in rice. In addition, the project linked functional data in rice and other species to switchgrass improvement efforts through curation of the most abundant class of regulators in the switchgrass genome. Characterizing natural diversity of switchgrass for variation in cell wall composition and properties, also known as quality, provides an unbiased avenue for identifying biologically viable diversity in switchgrass cell walls. To characterizing natural diversity, this project generated cell wall composition and enzymatic deconstruction data for ~450 genotypes of the Switchgrass Southern Association Collection (SSAC), a diverse collection composed of 36 switchgrass accessions from the southern U.S. distribution of switchgrass. Comparing these data with other measures of cell wall quality for the same samples demonstrated the complementary nature of the diverse characterization platforms now being used for biomass characterization. Association of the composition data with ~3.2K single nucleotide variant markers identified six significant single nucleotide variant markers co-associated with digestibility and another compositional trait. These

  18. India and the fissile material cut-off treaty: policy options

    International Nuclear Information System (INIS)

    Nayan, Rajiv

    2011-01-01

    The international community inside and outside the Conference of Disarmament is underscoring the need for concluding a fissile material cut-off treaty (FMCT). The Indian government, for a long period, has been sponsoring the idea. Notwithstanding the international stagnation, the issue has been instigating periodic debate in India on the Indian approach. The periodic revival of the issue requires that India revisit its policy on fissile material production as well as its approach towards a possible EVICT. This article examines the question: should India's approach to conclude an FMCT be within the UN institutional framework? The new international reality is pushing for a new context, new realignments and a fresh outlook for an FMCT. India should take its own time to support conclusion of an FMCT so that its national interests and security are not adversely affected. (author)

  19. Build an Interactive Word Wall

    Science.gov (United States)

    Jackson, Julie

    2018-01-01

    Word walls visually display important vocabulary covered during class. Although teachers have often been encouraged to post word walls in their classrooms, little information is available to guide them. This article describes steps science teachers can follow to transform traditional word walls into interactive teaching tools. It also describes a…

  20. Near wall combustion modeling in spark ignition engines. Part A: Flame–wall interaction

    International Nuclear Information System (INIS)

    Demesoukas, Sokratis; Caillol, Christian; Higelin, Pascal; Boiarciuc, Andrei; Floch, Alain

    2015-01-01

    Highlights: • A model for flame–wall interaction in addition to flame wrinkling by turbulence is proposed. • Two sparkplug positions and two lengths are used in a test engine for model validation. • Flame–wall interaction decreases the maximum values of cylinder pressure and heat release rates. • The impact of combustion chamber geometry is taken into account by the flame–wall interaction model. - Abstract: Research and design in the field of spark ignition engines seek to achieve high performance while conserving fuel economy and low pollutant emissions. For the evaluation of various engine configurations, numerical simulations are favored, since they are quick and less expensive than experiments. Various zero-dimensional combustion models are currently used. Both flame front reactions and post-flame processes contribute to the heat release rate. The first part of this study focuses on the role of the flame front on the heat release rate, by modeling the interaction of the flame front with the chamber wall. Post-flame reactions are dealt with in Part B of the study. The basic configurations of flame quenching in laminar flames are also applicable in turbulent flames, which is the case in spark ignition engines. A simplified geometric model of the combustion chamber was used to calculate the mean flame surface, the flame volume and the distribution of flame surface as a function of the distance from the wall. The flame–wall interaction took into account the geometry of the combustion chamber and of the flame, aerodynamic turbulence and the in-cylinder pressure and temperature conditions, through a phenomenological attenuation function of the wrinkling factor. A modified global wrinkling factor as a function of the mean surface distance distribution from the wall was calculated. The impact of flame–wall interaction was simulated for four configurations of the sparkplug position and length: centered and lateral position, and standard and projected

  1. [Validation of a cutoff point for the short version of the Depression Scale of the Center for Epidemiologic Studies in older Mexican adults].

    Science.gov (United States)

    Salinas-Rodríguez, Aarón; Manrique-Espinoza, Betty; Acosta-Castillo, Gilberto Isaac; Franco-Núñez, Aurora; Rosas-Carrasco, Oscar; Gutiérrez-Robledo, Luis Miguel; Sosa-Ortiz, Ana Luisa

    2014-01-01

    To identify a valid cutoff point associated with Center for Epidemiologic Studies, Depression Scale (CES-D) of seven items, which allows the classification of older adults according to presence/absence of clinically significant depressive symptoms. Screening study with 229 older adults residing in two states of Mexico (Morelos and Tlaxcala), which were part of the sample from the National Survey of Health and Nutrition, 2012. We estimated the sensitivity and specificity associated with the selected cutoff points using the diagnostic criteria of ICD-10 (International Classification of Diseases, 10th revision) and DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, fourth edition). The cutoff point estimated was CES-D=5. According to the ICD-10 sensitivity and specificity were 83.3 and 90.2%, and ROC was 87%. Using DSM-IV, the values were 85, 83.2, and 84%, respectively. The short version of the CES-D can be used as a screening test to identify probable cases of older adults with clinically significant depressive symptoms.

  2. What is the optimal cutoff value of the axis-line-angle technique for evaluating trunk imbalance in coronal plane?

    Science.gov (United States)

    Zhang, Rui-Fang; Fu, Yu-Chuan; Lu, Yi; Zhang, Xiao-Xia; Hu, Yu-Min; Zhou, Yong-Jin; Tian, Nai-Feng; He, Jia-Wei; Yan, Zhi-Han

    2017-02-01

    Accurately evaluating the extent of trunk imbalance in the coronal plane is significant for patients before and after treatment. We preliminarily practiced a new method, axis-line-angle technique (ALAT), for evaluating coronal trunk imbalance with excellent intra-observer and interobserver reliability. Radiologists and surgeons were encouraged to use this method in clinical practice. However, the optimal cutoff value of the ALAT for determination of the extent of coronal trunk imbalance has not been calculated up to now. The purpose of this study was to identify the cutoff value of the ALAT that best predicts a positive measurement point to assess coronal balance or imbalance. A retrospective study at a university affiliated hospital was carried out. A total of 130 patients with C7-central sacral vertical line (CSVL) >0 mm and aged 10-18 years were recruited in this study from September 2013 to December 2014. Data were analyzed to determine the optimal cutoff value of the ALAT measurement. The C7-CSVL and ALAT measurements were conducted respectively twice on plain film within a 2-week interval by two radiologists. The optimal cutoff value of the ALAT was analyzed via receiver operating characteristic (ROC) curve. Comparison variables were performed with chi-square test between the C7-CSVL and ALAT measurements for evaluating trunk imbalance. Kappa agreement coefficient method was used to test the intra-observer and interobserver agreement of C7-CSVL and ALAT. The ROC curve area for the ALAT was 0.82 (95% confidence interval: 0.753-0.894, pimbalance (p>.05). Intra-observer agreement values for the C7-CSVL measurements by observers 1 and 2 were 0.79 and 0.91 (pimbalance in the coronal plane with a high level of intra-observer and interobserver agreement, which suggests that the ALAT is suitable for clinical use. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. First wall of thermonuclear device

    International Nuclear Information System (INIS)

    Kizawa, Makoto; Koizumi, Makoto; Nishihara, Yoshihiro.

    1990-01-01

    The first wall of a thermonuclear device is constituted with inner wall tiles, e.g. made of graphite and metal substrates for fixing them. However, since the heat expansion coefficient is different between the metal substrates and intermediate metal members, thermal stresses are caused to deteriorate the endurance of the inner wall tiles. In view of the above, low melting metals are disposed at the portion of contact between the inner wall tiles and the metal substrates and, further, a heat pipe structure is incorporated into the metal substrates. Under the thermal load, for example, during operation of the thermonuclear device, the low melting metals at the portion of contact are melted into liquid metals to enhance the state of contact between the inner wall tiles and the metal substrate to reduce the heat resistance and improve the heat conductivity. Even if there is a difference in the heat expansion coefficient between the inner wall tiles and the metal substrates, neither sharing stresses not thermal stresses are caused. Further, since the heat pipe structure is incorporated into the metal substrates, the lateral unevenness of the temperature in the metal substrates can be eliminated. Thus, the durability of the inner wall tiles can be improved. (N.H.)

  4. Optimal plasma progranulin cutoff value for predicting null progranulin mutations in neurodegenerative diseases: a multicenter Italian study.

    Science.gov (United States)

    Ghidoni, Roberta; Stoppani, Elena; Rossi, Giacomina; Piccoli, Elena; Albertini, Valentina; Paterlini, Anna; Glionna, Michela; Pegoiani, Eleonora; Agnati, Luigi F; Fenoglio, Chiara; Scarpini, Elio; Galimberti, Daniela; Morbin, Michela; Tagliavini, Fabrizio; Binetti, Giuliano; Benussi, Luisa

    2012-01-01

    Recently, attention was drawn to a role for progranulin in the central nervous system with the identification of mutations in the progranulin gene (GRN) as an important cause of frontotemporal lobar degeneration. GRN mutations are associated with a strong reduction of circulating progranulin and widely variable clinical phenotypes: thus, the dosage of plasma progranulin is a useful tool for a quick and inexpensive large-scale screening of carriers of GRN mutations. To establish the best cutoff threshold for normal versus abnormal levels of plasma progranulin. 309 cognitively healthy controls (25-87 years of age), 72 affected and unaffected GRN+ null mutation carriers (24-86 years of age), 3 affected GRN missense mutation carriers, 342 patients with neurodegenerative diseases and 293 subjects with mild cognitive impairment were enrolled at the Memory Clinic, IRCCS S. Giovanni di Dio-Fatebenefratelli, Brescia, Italy, and at the Alzheimer Unit, Ospedale Maggiore Policlinico and IRCCS Istituto Neurologico C. Besta, Milan, Italy. Plasma progranulin levels were measured using an ELISA kit (AdipoGen Inc., Seoul, Korea). Plasma progranulin did not correlate with age, gender or body mass index. We established a new plasma progranulin protein cutoff level of 61.55 ng/ml that identifies, with a specificity of 99.6% and a sensitivity of 95.8%, null mutation carriers among subjects attending to a memory clinic. Affected and unaffected GRN null mutation carriers did not differ in terms of circulating progranulin protein (p = 0.686). A significant disease anticipation was observed in GRN+ subjects with the lowest progranulin levels. We propose a new plasma progranulin protein cutoff level useful for clinical practice. Copyright © 2011 S. Karger AG, Basel.

  5. A film-based wall shear stress sensor for wall-bounded turbulent flows

    Science.gov (United States)

    Amili, Omid; Soria, Julio

    2011-07-01

    In wall-bounded turbulent flows, determination of wall shear stress is an important task. The main objective of the present work is to develop a sensor which is capable of measuring surface shear stress over an extended region applicable to wall-bounded turbulent flows. This sensor, as a direct method for measuring wall shear stress, consists of mounting a thin flexible film on the solid surface. The sensor is made of a homogeneous, isotropic, and incompressible material. The geometry and mechanical properties of the film are measured, and particles with the nominal size of 11 μm in diameter are embedded on the film's surface to act as markers. An optical technique is used to measure the film deformation caused by the flow. The film has typically deflection of less than 2% of the material thickness under maximum loading. The sensor sensitivity can be adjusted by changing the thickness of the layer or the shear modulus of the film's material. The paper reports the sensor fabrication, static and dynamic calibration procedure, and its application to a fully developed turbulent channel flow at Reynolds numbers in the range of 90,000-130,000 based on the bulk velocity and channel full height. The results are compared to alternative wall shear stress measurement methods.

  6. Domain wall engineering through exchange bias

    International Nuclear Information System (INIS)

    Albisetti, E.; Petti, D.

    2016-01-01

    The control of the structure and position of magnetic domain walls is at the basis of the development of different magnetic devices and architectures. Several nanofabrication techniques have been proposed to geometrically confine and shape domain wall structures; however, a fine tuning of the position and micromagnetic configuration is hardly achieved, especially in continuous films. This work shows that, by controlling the unidirectional anisotropy of a continuous ferromagnetic film through exchange bias, domain walls whose spin arrangement is generally not favored by dipolar and exchange interactions can be created. Micromagnetic simulations reveal that the domain wall width, position and profile can be tuned by establishing an abrupt change in the direction and magnitude of the exchange bias field set in the system. - Highlights: • Micromagnetic simulations study domain walls in exchange biased thin films. • Novel domain wall configurations can be stabilized via exchange bias. • Domain walls nucleate at the boundary of regions with different exchange bias. • Domain wall width and spin profile are controlled by tuning the exchange bias.

  7. A cautionary note about the cross-national and clinical validity of cut-off points for the Maslach Burnout Inventory.

    Science.gov (United States)

    Schaufeli, W B; Van Dierendonck, D

    1995-06-01

    In the present study, burnout scores of three samples, as measured with the Maslach Burnout Inventory, were compared: (1) the normative American sample from the test-manual (N = 10,067), (2) the normative Dutch sample (N = 3,892), and (3) a Dutch outpatient sample (N = 142). Generally, the highest burnout scores were found for the outpatient sample, followed by the American and Dutch normative samples, respectively. Slightly different patterns were noted for each of the three components. Probably sampling bias, i.e., the healthy worker effect, or cultural value patterns, i.e., femininity versus masculinity, might be responsible for the results. It is concluded that extreme caution is required when cut-off points are used to classify individuals by burnout scores; only nation-specific and clinically derived cut-off points should be employed.

  8. Anomalous behavior of cutoff rigidity variation in the region of the Mexico station during a magnetic superstorm on 20 November 2003

    Directory of Open Access Journals (Sweden)

    V. V. Pchelkin

    2007-08-01

    Full Text Available The pioneering storm-time model of magnetospheric magnetic field T01S made possible trajectory calculations for the events of giant magnetic storms. We have performed such calculations for a unique magnetic storm on 20 November 2003. In our previous paper, Belov et al. (2005, dedicated to the magnetospheric effects of cosmic rays (CR during this storm, we revealed an anomalous behavior of a cutoff rigidity variation at the Mexico station. Here, by trajectory calculations, we demonstrate that this peculiarity persists in the latitudinal and longitudinal curves of cutoff rigidity (Rc for both quiet and storm-time conditions and thus should be considered as physically meaningful.

  9. Hyphal walls of isolated lichen fungi

    International Nuclear Information System (INIS)

    Galun, M.; Braun, A.; Frensdorff, A.; Galun, E.

    1976-01-01

    The hyphal walls of three mycobionts, isolated from the lichens Xanthoria parietina, Tornabenia intricata and Sarcogyne sp. were investigated by two techniques: microaudiography of fungal colonies exposed to radioactive carbohydrate precursors; and binding, in vivo, of fluorescein conjugated lectins to hyphal walls of such colonies. N-( 3 H) acetylglucosamine was readily incorporated into tips, young hyphal walls and septa of the three mycobionts and the free-living fungus Trichoderma viride, but not into Phytophthora citrophthora, indicating that chitin is a major component of the mycobionts' hyphal walls. All three mycobionts, but neither of the free-living fungi, incorporated ( 3 H) mannose and ( 3 H) mannitol into their hyphal walls. Fluorescein-conjugated wheat germ agglutinin was bound to the hyphal walls of the three mycobionts and T. viride, but not to the walls of P. citrophthora; the binding pattern was similar to the grain pattern obtained in audiographs after short N-( 3 H) acetylglucosamine labelling. As wheat germ agglutinin binds specifically to chitin oligomers, the lectin binding tests further confirmed that chitin is a mycobiont hyphal wall component. Binding characteristics of several fluorescein-conjugated lectins to the three mycobionts indicated that this technique can yield useful information concerning the chemical composition of hyphal wall surfaces. (orig./AJ) [de

  10. Observations of a low-frequency cutoff in magnetospheric radio noise received on Imp 6

    International Nuclear Information System (INIS)

    Vesecky, J.F.; Frankel, M.S.

    1975-01-01

    Observations of magnetospheric radio noise by the Goddard Space Flight Center radio experiment on the Imp 6 spacecraft have revealed a quasi-continuous component at frequencies between 30 and 110 kHz. When the spacecraft is in the interplanetary medium or the magnetosheath, a low-frequency cutoff often characterizes the otherwise power law (f - /sup alpha/) spectrum of this noise. A positive correlation is observed between this cutoff frequency f) and the solar wind plasma frequency f), deduced from the Los Alamos plasma experiment on the same spacecraft; on the average, f)approx. =1.3f). If one pictures the magnetosheath as a homogeneous layer of plasma lying between the radio noise source (at Lapprox.4--7) and the spacecraft in the interplanetary medium and having an electron density 2--3 times that of the solar wind, then one will expect f)approximately-greater-than2 1 / 2 f)--3 1 / 2 f). Within the limits of experimental error this simple model correctly accounts for the observations. A rough calculation shows that radio wave scattering by electron density fluctuations in the magnetosheath plasma is likely to be important for frequencies below 200 kHz. However, the effects of such scattering cannot be detected in the Imp 6 observations considered here because neither concurrent measurements nor sufficiently accurate models of the necessar []magnetosheath plasma parameters are presently available

  11. Thin walls in regions with vacuum energy

    Energy Technology Data Exchange (ETDEWEB)

    Garfinkle, D [Florida Univ., Gainesville, FL (USA). Dept. of Physics; Vuille, C [Embry-Riddle Aeronautical Univ., Prescott, AZ (USA). Dept. of Math/Physical Science

    1989-12-01

    The motion of a thin wall is treated in the case where the regions on either side of the wall have vacuum energy. This treatment generalises previous results involving domain walls in vacuum and also previous results involving the properties of false vacuum bubbles. The equation of state for a domain wall is{tau} = {sigma} where {tau} is the tension in the wall and {sigma} is the energy density. We consider the motion of a more general class of walls having equation of state {tau}{Gamma}{sigma} with 0{le}{Gamma}{le}1. Spherically symmetric and planar symmetric walls are examined. We also find the global structure of the wall spacetime. (author).

  12. Exploration of the optimal diameter cut-off value in patients with nonfunctional adrenal tumor suitable for surgery

    Directory of Open Access Journals (Sweden)

    Dan-dan LIU

    2016-12-01

    Full Text Available Objective  To analyze the pathology of the patients with nonfunctional adrenal tumor (NFA, and explore the optimal diameter cut-off value. Methods  The clinical data of 243 patients with NFA, evaluated in the Department of Endocrinology and operated in the Department of Urology of General Hospital of Chinese PLA from Feb. 1996 to Jan. 2016, were collected. The patients were divided into two groups according to pathology: those in real demand of surgery were classified to the surgery-need group (n=57, while the others were categorized as the surgery-unwanted group (n=186. The general situation, pathological type and tumor diameter of the two groups and the factors affecting the surgery were analyzed, and the ROC curve was used to explore the optimal surgery cut-off value, which represents the maximum value of the sum of sensitivity and specificity. Results  Of the 57 patients in surgery-need group (27 males and 30 females, the lesions were on the right in 31 cases, on the left in 25 cases, and on bilateral sides in 1 case; the median of lesion diameter was 4.5cm, and the average age was 41.5±12.1 years old. Of the 186 patients in surgery-unwanted group (87 males and 99 females, the lesions were on the right in 99 cases, on the left in 86 cases, and on bilateral sides in 1 case; the median of lesion diameter was 3.0cm, and the average age was 50.6±10.9 years old. Logistic regression revealed that lesion diameter might be a risk factor (OR=1.340, 95%CI 1.266-1.418, P=0.000 and age be a protective factor (OR=0.942, 95%CI 0.929-0.955, P=0.000 for real demand of surgery. The area under the ROC curve (AUC of lesion diameter was 0.757(95%CI 0.681-0.833. The optimal cut-off value was 4.1cm (sensitivity 60.7% and specificity 83.0%. Conclusions  Younger patients with bigger lesion diameter may have greater possibility for surgery. The optimal surgery cut-off value of the lesion diameter is 4.1cm. DOI: 10.11855/j.issn.0577-7402.2016.11.11

  13. High harmonic generation at the tunneling ionization of atoms by intense laser radiation near the classical cut-off

    Science.gov (United States)

    Gets, A. V.; Krainov, V. P.

    2018-01-01

    The yield of spontaneous photons at the tunneling ionization of atoms by intense low-frequency laser radiation near the classical cut-off is estimated analytically by using the three-step model. The Bell-shaped dependence in the universal photon spectrum is explained qualitatively.

  14. The Potential of Established Fitness Cut-off Points for Monitoring Women with Fibromyalgia : The al-Ándalus Project

    NARCIS (Netherlands)

    Castro-Piñero, José; Aparicio, Virginia A; Estévez-López, Fernando; Álvarez-Gallardo, Inmaculada C; Borges-Cosic, Milkana; Soriano-Maldonado, Alberto; Delgado-Fernández, Manuel; Segura-Jiménez, Víctor

    2017-01-01

    The aim of the present study was to determinate whether fitness cut-off points discriminate the severity of major fibromyalgia symptoms and health-related quality of life. Additionally, we investigated which American Colleague of Rheumatology (ACR) fibromyalgia criteria (1990 vs. modified 2010)

  15. Interannual rainfall variability over the Cape south coast of South Africa linked to cut-off low associated rainfall

    CSIR Research Space (South Africa)

    Engelbrecht, CJ

    2014-10-01

    Full Text Available The influence of cut-off low (COL) associated rainfall on interannual rainfall variability over the Cape south coast region of South Africa for the period 1979-2011 is investigated. COLs are objectively identified and tracked on daily average 500 h...

  16. Reliability, Validity, and Optimal Cutoff Score of the Montreal Cognitive Assessment (Changsha Version) in Ischemic Cerebrovascular Disease Patients of Hunan Province, China

    Science.gov (United States)

    Tu, Qiu-yun; Jin, Hui; Ding, Bin-rong; Yang, Xia; Lei, Zeng-hui; Bai, Song; Zhang, Ying-dong; Tang, Xiang-qi

    2013-01-01

    Background/Aims The goal of this study was to examine the reliability and validity of the Changsha version of the Montreal Cognitive Assessment (MoCA-CS) in ischemic cerebrovascular disease patients of Hunan Province, China, and to explore the optimal cutoff score for detecting vascular cognitive impairment-no dementia (VCI-ND) and vascular dementia (VD). Methods Three hundred and thirty-eight ischemic cerebrovascular disease patients (131 with normal cognition, 111 with VCI-ND, and 96 with VD) and 132 healthy controls were recruited. All participants accepted examination by the MoCA-CS, Mini-Mental State Examination (MMSE), and other related scales. A detailed neuropsychological battery was used for making a final cognitive diagnosis. SPSS 16.0 statistical software was used for reliability, validity examination, and optimal cutoff score detection. Results Cronbach's α of the MoCA-CS was 0.884, and test-retest and interrater reliability of the MoCA-CS were 0.966 and 0.926, respectively. MoCA-CS scores were highly correlated with MMSE scores (r = 0.867) and simplified intelligence quotients (r = 0.822). The results indicate that 1 point should be added for subjects with less than 6 years of education, and that the optimal cutoff score for detecting VCI-ND is 26/27 (sensitivity 96.1%, specificity 75.6%), whereas the optimal cutoff score for detecting VD is 16/17 (sensitivity 92.7%, specificity 96.3%). Conclusion The MoCA-CS has good reliability and validity, and is a useful cognitive screening instrument for detecting VCI in the Chinese population. PMID:23637698

  17. Reliability, Validity, and Optimal Cutoff Score of the Montreal Cognitive Assessment (Changsha Version in Ischemic Cerebrovascular Disease Patients of Hunan Province, China

    Directory of Open Access Journals (Sweden)

    Qiu-yun Tu

    2013-02-01

    Full Text Available Background/Aims: The goal of this study was to examine the reliability and validity of the Changsha version of the Montreal Cognitive Assessment (MoCA-CS in ischemic cerebrovascular disease patients of Hunan Province, China, and to explore the optimal cutoff score for detecting vascular cognitive impairment-no dementia (VCI-ND and vascular dementia (VD. Methods: Three hundred and thirty-eight ischemic cerebrovascular disease patients (131 with normal cognition, 111 with VCI-ND, and 96 with VD and 132 healthy controls were recruited. All participants accepted examination by the MoCA-CS, Mini-Mental State Examination (MMSE, and other related scales. A detailed neuropsychological battery was used for making a final cognitive diagnosis. SPSS 16.0 statistical software was used for reliability, validity examination, and optimal cutoff score detection. Results: Cronbach’s α of the MoCA-CS was 0.884, and test-retest and interrater reliability of the MoCA-CS were 0.966 and 0.926, respectively. MoCA-CS scores were highly correlated with MMSE scores (r = 0.867 and simplified intelligence quotients (r = 0.822. The results indicate that 1 point should be added for subjects with less than 6 years of education, and that the optimal cutoff score for detecting VCI-ND is 26/27 (sensitivity 96.1%, specificity 75.6%, whereas the optimal cutoff score for detecting VD is 16/17 (sensitivity 92.7%, specificity 96.3%. Conclusion: The MoCA-CS has good reliability and validity, and is a useful cognitive screening instrument for detecting VCI in the Chinese population.

  18. Effects of the change in cutoff values for human epidermal growth factor receptor 2 status by immunohistochemistry and fluorescence in situ hybridization: a study comparing conventional brightfield microscopy, image analysis-assisted microscopy, and interobserver variation.

    Science.gov (United States)

    Atkinson, Roscoe; Mollerup, Jens; Laenkholm, Anne-Vibeke; Verardo, Mark; Hawes, Debra; Commins, Deborah; Engvad, Birte; Correa, Adrian; Ehlers, Charlotte Cort; Nielsen, Kirsten Vang

    2011-08-01

    New guidelines for HER2 testing have been introduced. To evaluate the difference in HER2 assessment after introduction of new cutoff levels for both immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) and to compare interobserver agreement and time to score between image analysis and conventional microscopy. Samples from 150 patients with breast cancer were scored by 7 pathologists using conventional microscopy, with a cutoff of both 10% and 30% IHC-stained cells, and using automated microscopy with image analysis. The IHC results were compared individually and to HER2 status as determined by FISH, using both the approved cutoff of 2.0 and the recently introduced cutoff of 2.2. High concordance was found in IHC scoring among the 7 pathologists. The 30% cutoff led to slightly fewer positive IHC observations. Introduction of a FISH equivocal zone affected 4% of the FISH scores. If cutoff for FISH is kept at 2.0, no difference in patient selection is found between the 10% and the 30% IHC cutoff. Among the 150 breast cancer samples, the new 30% IHC and 2.2 FISH cutoff levels resulted in one case without a firm diagnosis because both IHC and FISH were equivocal. Automated microscopy and image analysis-assisted IHC led to significantly better interobserver agreement among the 7 pathologists, with an increase in mean scoring time of only about 30 seconds per slide. The change in cutoff levels led to a higher concordance between IHC and FISH, but fewer samples were classified as HER2 positive.

  19. Dynamical implications of sample shape for avalanches in 2-dimensional random-field Ising model with saw-tooth domain wall

    Science.gov (United States)

    Tadić, Bosiljka

    2018-03-01

    We study dynamics of a built-in domain wall (DW) in 2-dimensional disordered ferromagnets with different sample shapes using random-field Ising model on a square lattice rotated by 45 degrees. The saw-tooth DW of the length Lx is created along one side and swept through the sample by slow ramping of the external field until the complete magnetisation reversal and the wall annihilation at the open top boundary at a distance Ly. By fixing the number of spins N =Lx ×Ly = 106 and the random-field distribution at a value above the critical disorder, we vary the ratio of the DW length to the annihilation distance in the range Lx /Ly ∈ [ 1 / 16 , 16 ] . The periodic boundary conditions are applied in the y-direction so that these ratios comprise different samples, i.e., surfaces of cylinders with the changing perimeter Lx and height Ly. We analyse the avalanches of the DW slips between following field updates, and the multifractal structure of the magnetisation fluctuation time series. Our main findings are that the domain-wall lengths materialised in different sample shapes have an impact on the dynamics at all scales. Moreover, the domain-wall motion at the beginning of the hysteresis loop (HLB) probes the disorder effects resulting in the fluctuations that are significantly different from the large avalanches in the central part of the loop (HLC), where the strong fields dominate. Specifically, the fluctuations in HLB exhibit a wide multi-fractal spectrum, which shifts towards higher values of the exponents when the DW length is reduced. The distributions of the avalanches in this segments of the loops obey power-law decay and the exponential cutoffs with the exponents firmly in the mean-field universality class for long DW. In contrast, the avalanches in the HLC obey Tsallis density distribution with the power-law tails which indicate the new categories of the scale invariant behaviour for different ratios Lx /Ly. The large fluctuations in the HLC, on the other

  20. The cutoffs and performance of glycated hemoglobin for diagnosing diabetes and prediabetes in a young and middle-aged population and in an elderly population.

    Science.gov (United States)

    Yan, Shuang-Tong; Xiao, Hai-Ying; Tian, Hui; Li, Chun-Lin; Fang, Fu-Sheng; Li, Xiao-Ying; Cheng, Xiao-Ling; Li, Nan; Miao, Xin-Yu; Yang, Yan; Wang, Liang-Chen; Zou, Xiao-Man; Ma, Fang-Ling; He, Yao; Sai, Xiao-Yong

    2015-08-01

    The aims were to compare the appropriate cutoffs of glycated hemoglobin (HbA1c) in a population of varying ages and to evaluate the performance of HbA1c for diagnosing diabetes and prediabetes. A total of 1064 participants in the young and middle-aged group and 1671 in the elderly group were included and underwent HbA1c testing and an oral glucose tolerance test (OGTT). Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated to evaluate the optimal HbA1c cutoffs. Kappa coefficients were used to test for agreement between HbA1c categorization and OGTT-based diagnoses. The optimal HbA1c cutoffs for diagnosing diabetes were 5.7% (39 mmol/mol) in the young and middle-aged group with a sensitivity of 66.7%, specificity of 86.7%, and AUC of 0.821 (95% CI: 0.686, 0.955) and 5.9% (41 mmol/mol) in the elderly group with a sensitivity of 80.4%, specificity of 73.3%, and AUC of 0.831 (0.801, 0.861). The optimal cutoffs for diagnosing prediabetes were 5.6% (38 mmol/mol) and 5.7% (39 mmol/mol) in the young and middle-aged group and in the elderly group, respectively. Agreement between the OGTT-based diagnosis of diabetes or prediabetes and the optimal HbA1c cutoff was low (all kappa coefficients prediabetes were appropriate. Furthermore, the performance of HbA1c for diagnosing diabetes and prediabetes was poor. HbA1c should be used in combination with traditional glucose criteria when detecting and diagnosing diabetes or prediabetes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Plasma-wall interaction

    International Nuclear Information System (INIS)

    Reichle, R.

    2004-01-01

    This document gathers the 43 slides presented in the framework of the week long lecture 'hot plasmas 2004' and dedicated to plasma-wall interaction in a tokamak. This document is divided into 4 parts: 1) thermal load on the wall, power extraction and particle recovery, 2) basic edge plasma physics, 3) processes that drive the plasma-solid interaction, and 4) material conditioning (surface treatment...) for ITER

  2. Reconstitution of a secondary cell wall in a secondary cell wall-deficient Arabidopsis mutant.

    Science.gov (United States)

    Sakamoto, Shingo; Mitsuda, Nobutaka

    2015-02-01

    The secondary cell wall constitutes a rigid frame of cells in plant tissues where rigidity is required. Deposition of the secondary cell wall in fiber cells contributes to the production of wood in woody plants. The secondary cell wall is assembled through co-operative activities of many enzymes, and their gene expression is precisely regulated by a pyramidal cascade of transcription factors. Deposition of a transmuted secondary cell wall in empty fiber cells by expressing selected gene(s) in this cascade has not been attempted previously. In this proof-of-concept study, we expressed chimeric activators of 24 transcription factors that are preferentially expressed in the stem, in empty fiber cells of the Arabidopsis nst1-1 nst3-1 double mutant, which lacks a secondary cell wall in fiber cells, under the control of the NST3 promoter. The chimeric activators of MYB46, SND2 and ANAC075, as well as NST3, reconstituted a secondary cell wall with different characteristics from those of the wild type in terms of its composition. The transgenic lines expressing the SND2 or ANAC075 chimeric activator showed increased glucose and xylose, and lower lignin content, whereas the transgenic line expressing the MYB46 chimeric activator showed increased mannose content. The expression profile of downstream genes in each transgenic line was also different from that of the wild type. This study proposed a new screening strategy to identify factors of secondary wall formation and also suggested the potential of the artificially reconstituted secondary cell walls as a novel raw material for production of bioethanol and other chemicals. © The Author 2014. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists.

  3. Optimization of multiplane ?PIV for wall shear stress and wall topography characterization

    NARCIS (Netherlands)

    Rossi, M.; Lindken, R.; Westerweel, J.

    2009-01-01

    Multiplane ?PIV can be utilized to determine the wall shear stress and wall topology from the measured flow over a structured surface. A theoretical model was developed to predict the measurement error for the surface topography and shear stress, based on a theoretical analysis of the precision in

  4. Cutoff points of waist circumference and trunk and visceral fat for identifying children with elevated inflammation markers and adipokines: The Healthy Growth Study.

    Science.gov (United States)

    Karatzi, Kalliopi; Moschonis, George; Polychronopoulou, Maria Christina; Chrousos, George P; Lionis, Christos; Manios, Yannis

    2016-10-01

    Excessive fat storage is accompanied by several comorbidities in children and early identification of elevated abdominal fat may be extremely valuable in early prevention of cardiometabolic risk. The aim of the present study was to establish cutoff points for waist circumference trunk and visceral fat, thus identifying increased likelihood of elevated inflammatory markers and adipokines in children. A representative sample of schoolchildren (aged 9-13 y) participated in a cross-sectional epidemiologic study conducted in Greece. Anthropometric and physical examination data, biochemical indices, and socioeconomic information (collected from parents) were assessed for all children. Central adiposity markers (trunk and visceral fat) were collected with bioelectrical impedance analysis for 999 children. Specific cutoff values of abdominal adiposity indices indicating increased likelihood of elevated levels of C-reactive protein, interleukin-6, and leptin and decreased levels of adiponectin were calculated by sex. These cutoff values were; 67.5 cm for boys and 69.5 cm for girls for waist circumference, 17.75% for boys and 22.65% for girls for trunk fat mass percentage, and 3.95 for boys and 2.55 for girls for visceral fat rating. To our knowledge, this is the first study to establish simple cutoff points for abdominal adiposity indices identifying children at high risk for elevated inflammatory markers and decreased adipokine levels. Future studies are essential to confirm these findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Cut-off scores of a brief neuropsychological battery (NBACE for Spanish individual adults older than 44 years old.

    Directory of Open Access Journals (Sweden)

    Montserrat Alegret

    Full Text Available The neuropsychological battery used in Fundació ACE (NBACE is a relatively brief, and easy to administer, test battery that was designed to detect cognitive impairment in the adulthood. The NBACE includes measures of cognitive information processing speed, orientation, attention, verbal learning and memory, language, visuoperception, praxis and executive functions. The aim of the present study was to establish the cut-off scores for impairment for different levels of age and education that could be useful in the cognitive assessment of Spanish subjects who are at risk for cognitive impairment, especially dementia. Data from 1018 patients with a mild dementia syndrome, and 512 cognitively healthy subjects, older than 44 years, from the Memory Clinic of Fundació ACE (Barcelona, Spain were analyzed. In the whole sample, cut-off scores and sensitivity/specificity values were calculated for six conditions after combining 3 age ranges (44 to 64; 65 to 74; and older than 74 years old by 2 educational levels (until Elementary school; and more than Elementary school. Moreover, general cut-offs are reported for Catalan and Spanish speakers. The results showed that most of NBACE tests reached good sensitivity and specificity values, except for Ideomotor praxis, Repetition and Verbal Comprehension tests, which had a ceiling effect. Word List Learning from the Wechsler Memory Scale-III and Semantic Verbal Fluency were the most useful tests to discriminate between cognitively healthy and demented subjects. The NBACE has been shown to be a useful tool able to detect cognitive impairment, especially dementia, in older than 44 years Spanish persons.

  6. Wall roughness induces asymptotic ultimate turbulence

    Science.gov (United States)

    Zhu, Xiaojue; Verschoof, Ruben A.; Bakhuis, Dennis; Huisman, Sander G.; Verzicco, Roberto; Sun, Chao; Lohse, Detlef

    2018-04-01

    Turbulence governs the transport of heat, mass and momentum on multiple scales. In real-world applications, wall-bounded turbulence typically involves surfaces that are rough; however, characterizing and understanding the effects of wall roughness on turbulence remains a challenge. Here, by combining extensive experiments and numerical simulations, we examine the paradigmatic Taylor-Couette system, which describes the closed flow between two independently rotating coaxial cylinders. We show how wall roughness greatly enhances the overall transport properties and the corresponding scaling exponents associated with wall-bounded turbulence. We reveal that if only one of the walls is rough, the bulk velocity is slaved to the rough side, due to the much stronger coupling to that wall by the detaching flow structures. If both walls are rough, the viscosity dependence is eliminated, giving rise to asymptotic ultimate turbulence—the upper limit of transport—the existence of which was predicted more than 50 years ago. In this limit, the scaling laws can be extrapolated to arbitrarily large Reynolds numbers.

  7. Near-wall serpentine cooled turbine airfoil

    Science.gov (United States)

    Lee, Ching-Pang

    2013-09-17

    A serpentine coolant flow path (54A-54G) formed by inner walls (50, 52) in a cavity (49) between pressure and suction side walls (22, 24) of a turbine airfoil (20A). A coolant flow (58) enters (56) an end of the airfoil, flows into a span-wise channel (54A), then flows forward (54B) over the inner surface of the pressure side wall, then turns behind the leading edge (26), and flows back along a forward part of the suction side wall, then follows a loop (54E) forward and back around an inner wall (52), then flows along an intermediate part of the suction side wall, then flows into an aft channel (54G) between the pressure and suction side walls, then exits the trailing edge (28). This provides cooling matched to the heating topography of the airfoil, minimizes differential thermal expansion, revives the coolant, and minimizes the flow volume needed.

  8. Thinner regions of intracranial aneurysm wall correlate with regions of higher wall shear stress: a 7.0 tesla MRI

    Science.gov (United States)

    Blankena, Roos; Kleinloog, Rachel; Verweij, Bon H.; van Ooij, Pim; ten Haken, Bennie; Luijten, Peter R.; Rinkel, Gabriel J.E.; Zwanenburg, Jaco J.M.

    2016-01-01

    Purpose To develop a method for semi-quantitative wall thickness assessment on in vivo 7.0 tesla (7T) MRI images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. Materials and Methods Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients, who underwent 7T MRI with a TSE based vessel wall sequence (0.8 mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to signal of nearby brain tissue and were used as measure for apparent wall thickness (AWT). Spatial wall thickness variation was determined as the interquartile range in AWT (the middle 50% of the AWT range). Wall shear stress was determined using phase contrast MRI (0.5 mm isotropic resolution). We performed visual and statistical comparisons (Pearson’s correlation) to study the relation between wall thickness and wall shear stress. Results 3D colored AWT maps of the aneurysms showed spatial AWT variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of one voxel (0.8mm)). In all aneurysms, AWT was inversely related to WSS (mean correlation coefficient −0.35, P<0.05). Conclusions A method was developed to measure the wall thickness semi-quantitatively, using 7T MRI. An inverse correlation between wall shear stress and AWT was determined. In future studies, this non-invasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and –rupture. PMID:26892986

  9. Cut-Off Points for Mild, Moderate, and Severe Pain on the Numeric Rating Scale for Pain in Patients with Chronic Musculoskeletal Pain: Variability and Influence of Sex and Catastrophizing.

    Science.gov (United States)

    Boonstra, Anne M; Stewart, Roy E; Köke, Albère J A; Oosterwijk, René F A; Swaan, Jeannette L; Schreurs, Karlein M G; Schiphorst Preuper, Henrica R

    2016-01-01

    Objectives: The 0-10 Numeric Rating Scale (NRS) is often used in pain management. The aims of our study were to determine the cut-off points for mild, moderate, and severe pain in terms of pain-related interference with functioning in patients with chronic musculoskeletal pain, to measure the variability of the optimal cut-off points, and to determine the influence of patients' catastrophizing and their sex on these cut-off points. Methods: 2854 patients were included. Pain was assessed by the NRS, functioning by the Pain Disability Index (PDI) and catastrophizing by the Pain Catastrophizing Scale (PCS). Cut-off point schemes were tested using ANOVAs with and without using the PSC scores or sex as co-variates and with the interaction between CP scheme and PCS score and sex, respectively. The variability of the optimal cut-off point schemes was quantified using bootstrapping procedure. Results and conclusion: The study showed that NRS scores ≤ 5 correspond to mild, scores of 6-7 to moderate and scores ≥8 to severe pain in terms of pain-related interference with functioning. Bootstrapping analysis identified this optimal NRS cut-off point scheme in 90% of the bootstrapping samples. The interpretation of the NRS is independent of sex, but seems to depend on catastrophizing. In patients with high catastrophizing tendency, the optimal cut-off point scheme equals that for the total study sample, but in patients with a low catastrophizing tendency, NRS scores ≤ 3 correspond to mild, scores of 4-6 to moderate and scores ≥7 to severe pain in terms of interference with functioning. In these optimal cut-off schemes, NRS scores of 4 and 5 correspond to moderate interference with functioning for patients with low catastrophizing tendency and to mild interference for patients with high catastrophizing tendency. Theoretically one would therefore expect that among the patients with NRS scores 4 and 5 there would be a higher average PDI score for those with low

  10. Development of P4140 video data wall projector; Video data wall projector

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, H.; Inoue, H. [Toshiba Corp., Tokyo (Japan)

    1998-12-01

    The P4140 is a 3 cathode-ray tube (CRT) video data wall projector for super video graphics array (SVGA) signals. It is used as an image display unit, providing a large screen when several sets are put together. A high-quality picture has been realized by higher resolution and improved color uniformity technology. A new convergence adjustment system has also been developed through the optimal combination of digital and analog technologies. This video data wall installation has been greatly enhanced by the automation of cubes and cube performance settings. The P4140 video data wall projector can be used for displaying not only data but video as well. (author)

  11. Break-apart interphase fluorescence in situ hybridization assay in papillary thyroid carcinoma: on the road to optimizing the cut-off level for RET/PTC rearrangements.

    Science.gov (United States)

    Colato, Chiara; Vicentini, Caterina; Cantara, Silvia; Pedron, Serena; Brazzarola, Paolo; Marchetti, Ivo; Di Coscio, Giancarlo; Chilosi, Marco; Brunelli, Matteo; Pacini, Furio; Ferdeghini, Marco

    2015-05-01

    Chromosomal rearrangements of the RET proto-oncogene is one of the most common molecular events in papillary thyroid carcinoma (PTC). However, their pathogenic role and clinical significance are still debated. This study aimed to investigate the prevalence of RET/PTC rearrangement in a cohort of BRAF WT PTCs by fluorescence in situ hybridization (FISH) and to search a reliable cut-off level in order to distinguish clonal or non-clonal RET changes. Forty BRAF WT PTCs were analyzed by FISH for RET rearrangements. As controls, six BRAFV600E mutated PTCs, 13 follicular adenomas (FA), and ten normal thyroid parenchyma were also analyzed. We performed FISH analysis on formalin-fixed, paraffin-embedded tissue using a commercially available RET break-apart probe. A cut-off level equivalent to 10.2% of aberrant cells was accepted as significant. To validate FISH results, we analyzed the study cohort by qRT-PCR. Split RET signals above the cut-off level were observed in 25% (10/40) of PTCs, harboring a percentage of positive cells ranging from 12 to 50%, and in one spontaneous FA (1/13, 7.7%). Overall, the data obtained by FISH matched well with qRT-PCR results. Challenging findings were observed in five cases showing a frequency of rearrangement very close to the cut-off. FISH approach represents a powerful tool to estimate the ratio between broken and non-broken RET tumor cells. Establishing a precise FISH cut-off may be useful in the interpretation of the presence of RET rearrangement, primarily when this strategy is used for cytological evaluation or for targeted therapy. © 2015 European Society of Endocrinology.

  12. Receiver Operating Characteristic (ROC to Determine Cut-Off Points of Biomarkers in Lung Cancer Patients

    Directory of Open Access Journals (Sweden)

    Heidi L. Weiss

    2004-01-01

    Full Text Available The role of biomarkers in disease prognosis continues to be an important investigation in many cancer studies. In order for these biomarkers to have practical application in clinical decision making regarding patient treatment and follow-up, it is common to dichotomize patients into those with low vs. high expression levels. In this study, receiver operating characteristic (ROC curves, area under the curve (AUC of the ROC, sensitivity, specificity, as well as likelihood ratios were calculated to determine levels of growth factor biomarkers that best differentiate lung cancer cases versus control subjects. Selected cut-off points for p185erbB-2 and EGFR membrane appear to have good discriminating power to differentiate control tissues versus uninvolved tissues from patients with lung cancer (AUC = 89% and 90%, respectively; while AUC increased to at least 90% for selected cut-off points for p185erbB-2 membrane, EGFR membrane, and FASE when comparing between control versus carcinoma tissues from lung cancer cases. Using data from control subjects compared to patients with lung cancer, we presented a simple and intuitive approach to determine dichotomized levels of biomarkers and validated the value of these biomarkers as surrogate endpoints for cancer outcome.

  13. COMPARISON OF SENSORS FOR RESISTIVE WALL MODE FEEDBACK CONTROL. MILESTONE No.145 ''CONTAINING PLASMA INSTABILITIES WITH METAL WALLS''

    International Nuclear Information System (INIS)

    STRAIT, E.J.; CHU, M.S.; GAROFALO, A.M.; LAHAYE, R.J.; OKABAYASHI, M.; REIMERDES, H.; SCOVILLE, J.T.; TURNBULL, A.D.

    2002-01-01

    OAK A271 COMPARISON OF SENSORS FOR RESISTIVE WALL MODE FEEDBACK CONTROL MILESTONE No.145 CONTAINING PLASMA INSTABILITIES WITH METAL WALLS. The most serious instabilities in the tokamak are those described by ideal magneto-hydrodynamic theory. These modes limit the stable operating space of the tokamak. The ideal MHD calculations predict the stable operating space of the tokamak may be approximately doubled when a perfectly conducting metal wall is placed near the plasma boundary, compared to the case with no wall (free boundary). The unstable mode distortions of the plasma column cannot bulge out through a perfectly conducting wall. However, real walls have finite conductivity and when plasmas are operated in the regime between the free boundary stability limit and the perfectly conducting wall limit, the unstable mode encountered in that case the resistive wall mode, can leak out through the metal wall, allowing the mode to keep slowly growing. The slow growth affords the possibility of feedback stabilizing this mode with external coils. DIII-D is making good progress in such feedback stabilization research and in 2002 will use an improved set of mode sensors inside the vacuum vessel and closer to the plasma surface which are expected theoretically to improve the ability to stabilize the resistive wall mode

  14. Diurnal Periodicity in the Supply of Cell Wall Components during Wood Cell Wall Formation

    OpenAIRE

    細尾, 佳宏

    2012-01-01

    This review summarizes recent studies on the diurnal periodicity in wood cell wall formation, with a major focus on those that we have conducted. Differences in the innermost surface of developing secondary walls of differentiating conifer tracheids can be seen from day to night Cellulose microfibrils are clearly evident during the day, and amorphous material containing abundant hemicelluloses is prevalent at night. These findings suggest a diurnal periodicity in the supply of cell wall compo...

  15. Routine inspection effort required for verification of a nuclear material production cutoff convention

    International Nuclear Information System (INIS)

    Fishbone, L.G.; Sanborn, J.

    1994-12-01

    Preliminary estimates of the inspection effort to verify a Nuclear Material Cutoff Convention are presented. The estimates are based on (1) a database of about 650 facilities a total of eight states, i.e., the five nuclear-weapons states and three ''threshold'' states; (2) typical figures for inspection requirements for specific facility types derived from IAEA experience, where applicable; and (3) alternative estimates of inspection effort in cutoff options where full IAEA safeguards are not stipulated. Considerable uncertainty must be attached to the effort estimates. About 50--60% of the effort for each option is attributable to 16 large-scale reprocessing plants assumed to be in operation in the eight states; it is likely that some of these will be shut down by the time the convention enters into force. Another important question involving about one third of the overall effort is whether Euratom inspections in France and the U.K. could obviate the need for full-scale IAEA inspections at these facilities. Finally, the database does not yet contain many small-scale and military-related facilities. The results are therefore not presented as predictions but as the consequences of alternative assumptions. Despite the preliminary nature of the estimates, it is clear that a broad application of NPT-like safeguards to the eight states would require dramatic increases in the IAEA's safeguards budget. It is also clear that the major component of the increased inspection effort would occur at large reprocessing plants (and associated plutonium facilities). Therefore, significantly bounding the increased effort requires a limitation on the inspection effort in these facility types

  16. Mid-infrared pulsed laser ablation of the arterial wall. Mechanical origin of "acoustic" wall damage and its effect on wall healing

    NARCIS (Netherlands)

    van Erven, L.; van Leeuwen, T. G.; Post, M. J.; van der Veen, M. J.; Velema, E.; Borst, C.

    1992-01-01

    Pulsed mid-infrared lasers are an alternative to excimer lasers for transluminal angioplasty. The mid-infrared lasers, however, were reported to produce "acoustic" wall damage that might impair the immediate and long-term results. To study the immediate and long-term effects on the arterial wall,

  17. Turbine airfoil with outer wall thickness indicators

    Science.gov (United States)

    Marra, John J; James, Allister W; Merrill, Gary B

    2013-08-06

    A turbine airfoil usable in a turbine engine and including a depth indicator for determining outer wall blade thickness. The airfoil may include an outer wall having a plurality of grooves in the outer surface of the outer wall. The grooves may have a depth that represents a desired outer surface and wall thickness of the outer wall. The material forming an outer surface of the outer wall may be removed to be flush with an innermost point in each groove, thereby reducing the wall thickness and increasing efficiency. The plurality of grooves may be positioned in a radially outer region of the airfoil proximate to the tip.

  18. Finite element modeling of single-walled carbon nanotubes with introducing a new wall thickness

    International Nuclear Information System (INIS)

    Jalalahmadi, B; Naghdabadi, R

    2007-01-01

    A three-dimensional finite element (FE) model for armchair, zigzag and chiral single-walled carbon nanotubes (SWCNTs) is proposed. By considering the covalent bonds as connecting elements between carbon atoms, a nanotube is simulated as a space frame-like structure. Here, the carbon atoms act as joints of the connecting elements. To create the FE models, nodes are placed at the locations of carbon atoms and the bonds between them are modeled using three-dimensional elastic beam elements. Using Morse atomic potential, the elastic moduli of beam elements are obtained via considering a linkage between molecular and continuum mechanics. Also, a new wall thickness ( bond diameter) equal to 0.1296 nm is introduced. In order to demonstrate the applicability of FE model and new wall thickness, the influence of tube wall thickness, diameter and chirality on the Young's modulus of SWCNTs is investigated. It is found that the choice of wall thickness significantly affects the calculation of Young's modulus. For the values of wall thickness used in the literature, the Young's moduli are estimated which agree very well with the corresponding theoretical results and experimental measurements. We also investigate the dependence of elastic moduli on diameter and chirality of the nanotube. The larger tube diameter, the higher Young's modulus of SWCNT. The Young's modulus of chiral SWCNTs is found to be generally larger than that of armchair and zigzag SWCNTs. The presented results demonstrate that the proposed FE model and wall thickness may provide a valuable tool for studying the mechanical behavior of carbon nanotubes and their application in nano-composites

  19. Fusion: first wall problems

    International Nuclear Information System (INIS)

    Behrisch, R.

    1976-01-01

    Some of the relevant elementary atomic processes which are expected to be of significance to the first wall of a fusion reactor are reviewed. Up to the present, most investigations have been performed at relatively high ion energies, typically E greater than 5 keV, and even in this range the available data are very poor. If the plasma wall interaction takes place at energies of E greater than 1 keV the impurity introduction and first wall erosion which will take place predominantly by sputtering, will be large and may severely limit the burning time of the plasma. The wall bombardment and surface erosion will presumably not decrease substantially by introducing a divertor. The erosion can only be kept low if the energy of the bombarding ions and neutrals can be kept below the threshold for sputtering of 1 to 10 eV. 93 refs

  20. Determination of cosmic ray (CR) ionization path and iono/atmospheric cut-off energy from CR intervals III, IV and V in the planetary environments

    International Nuclear Information System (INIS)

    Velinov, P.

    2001-01-01

    In this paper are determined the ionization path and cut-off energies of the cosmic ray (CR) nuclei in relation to the general interaction model 'CR - ionosphere-middle atmosphere'. Here the ionization path and the iono/atmospheric cut-off energies of the galactic CR, solar CR and anomalous CR are separately considered in each energetic range, without taking into account the particle transfer from one range in another. This more general approach will be the object of a further paper

  1. Ultrasonography of chest wall lesion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  2. Ultrasonography of chest wall lesion

    International Nuclear Information System (INIS)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H.

    1989-01-01

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  3. A study of insulin resistance by HOMA-IR and its cut-off value to identify metabolic syndrome in urban Indian adolescents.

    Science.gov (United States)

    Singh, Yashpal; Garg, M K; Tandon, Nikhil; Marwaha, Raman Kumar

    2013-01-01

    Insulin resistance (IR) and associated metabolic abnormalities are increasingly being reported in the adolescent population. Cut-off value of homeostasis model of assessment IR (HOMA-IR) as an indicator of metabolic syndrome (MS) in adolescents has not been established. This study aimed to investigate IR by HOMA-IR in urban Indian adolescents and to establish cut-off values of HOMA-IR for defining MS. A total of 691 apparently healthy adolescents (295 with normal body mass index (BMI), 205 overweight, and 199 obese) were included in this cross-sectional study. MS in adolescents was defined by International Diabetes Federation (IDF) and Adult Treatment Panel III (ATP III) criteria. IR was calculated using the HOMA model. Mean height, waist circumference (WC), waist/hip ratio (WHR), waist/height ratio (WHtR), and blood pressure were significantly higher in boys as compared to girls. The HOMA-IR values increased progressively from normal weight to obese adolescents in both sexes. Mean HOMA-IR values increased progressively according to sexual maturity rating in both sexes. HOMA-IR value of 2.5 had a sensitivity of >70% and specificity of >60% for MS. This cut-off identified larger number of adolescents with MS in different BMI categories (19.7% in normal weight, 51.7% in overweight, and 77.0% in obese subjects) as compared to the use of IDF or ATP III criteria for diagnosing MS. Odds ratio for having IR (HOMA-IR of >2.5) was highest with WHtR (4.9, p pHOMA-IR increased with sexual maturity and with progression from normal to obese. A HOMA-IR cut-off of 2.5 provided the maximum sensitivity and specificity in diagnosing MS in both genders as per ATP III and IDF criteria.

  4. Accuracy and cut-off values of pepsinogens I, II and gastrin 17 for diagnosis of gastric fundic atrophy: influence of gastritis.

    Directory of Open Access Journals (Sweden)

    Dariush Nasrollahzadeh

    Full Text Available BACKGROUND: To establish optimal cutoff values for serologic diagnosis of fundic atrophy in a high-risk area for oesophageal squamous cell carcinoma and gastric cancer with high prevalence of Helicobacter pylori (H. pylori in Northern Iran, we performed an endoscopy-room-based validation study. METHODS: We measured serum pepsinogens I (PGI and II (PGII, gastrin 17 (G-17, and antibodies against whole H. pylori, or cytotoxin-associated gene A (CagA antigen among 309 consecutive patients in two major endoscopy clinics in northeastern Iran. Updated Sydney System was used as histology gold standard. Areas under curves (AUCs, optimal cutoff and predictive values were calculated for serum biomarkers against the histology. RESULTS: 309 persons were recruited (mean age: 63.5 years old, 59.5% female. 84.5% were H. pylori positive and 77.5% were CagA positive. 21 fundic atrophy and 101 nonatrophic pangastritis were diagnosed. The best cutoff values in fundic atrophy assessment were calculated at PGI40 pmol/l was 81% sensitive and 73.3% specific for diagnosing fundic atrophy. At cutoff concentration of 11.8 µg/l, PGII showed 84.2% sensitivity and 45.4% specificity to distinguish nonatrophic pangastritis. Exclusion of nonatrophic pangastritis enhanced diagnostic ability of PGI/PGII ratio (from AUC = 0.66 to 0.90 but did not affect AUC of PGI. After restricting study samples to those with PGII<11.8, the sensitivity of using PGI<56 to define fundic atrophy increased to 83.3% (95%CI 51.6-97.9 and its specificity decreased to 88.8% (95%CI 80.8-94.3. CONCLUSIONS: Among endoscopy clinic patients, PGII is a sensitive marker for extension of nonatrophic gastritis toward the corpus. PGI is a stable biomarker in assessment of fundic atrophy and has similar accuracy to PGI/PGII ratio among populations with prevalent nonatrophic pangastritis.

  5. Domain wall networks on solitons

    International Nuclear Information System (INIS)

    Sutcliffe, Paul

    2003-01-01

    Domain wall networks on the surface of a soliton are studied in a simple theory. It consists of two complex scalar fields, in 3+1 dimensions, with a global U(1)xZ n symmetry, where n>2. Solutions are computed numerically in which one of the fields forms a Q ball and the other field forms a network of domain walls localized on the surface of the Q ball. Examples are presented in which the domain walls lie along the edges of a spherical polyhedron, forming junctions at its vertices. It is explained why only a small restricted class of polyhedra can arise as domain wall networks

  6. Application of flexi-wall in noise barriers renewal

    Directory of Open Access Journals (Sweden)

    B. Daee

    2015-12-01

    Full Text Available This paper presents an experimental study on structural performance of an innovative noise barrier consisting of poly-block, light polyurethane foam (LPF and polyurea. This wall system (flexi-wall is intended to be employed as a vertical extension to existing noise barriers (sound walls in an accelerated construction method. To aid in the wall design, several mechanical tests were conducted on LPF specimens and two full-scale walls were then fabricated employing the same LPF material. The full-scale walls were subjected to lateral loading in order to establish their lateral resistance. A cyclic fatigue test was also performed on a full-scale flexi-wall in order to evaluate the performance of the wall under a repetitive loading condition. The results of the experiments indicated the suitability of flexi-wall in accelerated construction and confirmed that the structural performance of the wall system under lateral loading is satisfactory for the sound wall application. The experimental results were discussed and a preliminary design procedure for application of flexi-wall in sound wall applications was also developed.

  7. Solution of the Eliashberg equations for a very strong electron-phonon coupling with a low-energy cutoff

    International Nuclear Information System (INIS)

    Weger, M.; Barbiellini, B.; Jarlborg, T.; Peter, M.; Santi, G.

    1995-01-01

    We solve the Eliashberg equations for the case of an explicit vector k dependence of the interactions, and of the resulting self-energies Σ 1 ( vector k,ω), Σ 2 ( vector k,ω). We consider a strong energy-dependence of the electron-electron scattering-rate τ ee -1 , which is associated with a strong energy-dependence of the electron-phonon matrix element g(k,k'). We characterize this energy-dependence by a cutoff ξ 1 , which is of the order of the phonon frequency ω ph . We find that we can account for a large number of unexpected features of the superconductivity of the cuprates by the BCS electron-phonon theory, if we consider very large values of the McMillan coupling constant λ ph , and small values of the cutoff ξ 1 . Specifically, the Coulomb interaction is found not to depress T c ; the isotope effect is strongly reduced when ξ 1 ph . We find solutions in which the gap function Δ( vector k,ω) has extended s-wave symmetry but is very anisotropic. We suggest that the underlying cause of the strong energy-dependence is a very small electronic screening parameter at the Fermi surface; the electron-phonon matrix element g is abnormally large, and this accounts for the high transition temperatures of the cuprates. An order of magnitude estimate suggests that the electron-phonon mechanism can account for transition temperatures up to about 200 K. We thus propose a very-strong-coupling theory, in which the renormalization functions, in particular the energy-renormalization X, depend very strongly on the superconducting gap Δ, and thus display a very strong temperature-dependence between T c and T=0. An experimental manifestation of the very strong coupling with a small cutoff is a zero bias anomaly sometimes observed in tunneling experiments. (orig.)

  8. Refining Game Addiction Questionnairs: Evidence for a natural cut-off point?

    DEFF Research Database (Denmark)

    Nielsen, Rune Kristian

    2013-01-01

    This paper presents data from a pilot study, which was designed to illuminate critical flaws in the currently used instruments used to measure the prevalence of ‘computer game addiction’. The study found that the prevalence rate could be set anywhere between 23% and 0,6% depending on how the data...... is unique in the field of prevalence studies of computer game addiction both in its design and its findings. The findings and conclusions need to be addressed by future research in the area.......’ from ‘addicted gamers’ by making implicit assumptions about negative effects explicit will cause prevalence rates to drop even further. Unexpectedly, the data from this modified questionnaire provides preliminary evidence for a natural cut-off point that clearly separates addicted play from normal play...

  9. A unified wall function for compressible turbulence modelling

    Science.gov (United States)

    Ong, K. C.; Chan, A.

    2018-05-01

    Turbulence modelling near the wall often requires a high mesh density clustered around the wall and the first cells adjacent to the wall to be placed in the viscous sublayer. As a result, the numerical stability is constrained by the smallest cell size and hence requires high computational overhead. In the present study, a unified wall function is developed which is valid for viscous sublayer, buffer sublayer and inertial sublayer, as well as including effects of compressibility, heat transfer and pressure gradient. The resulting wall function applies to compressible turbulence modelling for both isothermal and adiabatic wall boundary conditions with the non-zero pressure gradient. Two simple wall function algorithms are implemented for practical computation of isothermal and adiabatic wall boundary conditions. The numerical results show that the wall function evaluates the wall shear stress and turbulent quantities of wall adjacent cells at wide range of non-dimensional wall distance and alleviate the number and size of cells required.

  10. The cut-off values of dietary energy intake for determining metabolic syndrome in hemodialysis patients: A clinical cross-sectional study

    Science.gov (United States)

    Duong, Tuyen Van; Wong, Te-Chih; Chen, Hsi-Hsien; Chen, Tzen-Wen; Chen, Tso-Hsiao; Hsu, Yung-Ho; Peng, Sheng-Jeng; Kuo, Ko-Lin; Wang, Chi-Sin; Tseng, I-Hsin; Feng, Yi-Wei; Chang, Tai-Yue; Su, Chien-Tien

    2018-01-01

    Dietary energy intake strongly linked to dialysis outcomes. We aimed to explore the optimal cut-off point of energy intake (EI) for identification of metabolic syndrome (MetS) in hemodialysis patients. The cross-sectional data of 243 hemodialysis patients from multi-dialysis centers in Taiwan was used. The dietary intake was assessed by using the three-day dietary questionnaire, and a 24-hour dietary recall, clinical and biochemical data were also evaluated. The MetS was diagnosed by the Harmonized Metabolic Syndrome criteria. The receiver operating characteristic (ROC) curve was to depict the optimal cut-off value of EI for the diagnosis of MetS. The logistic regression was also used to explore the association between inadequate EI and MetS. The optimal cut-off points of EI for identifying the MetS were 26.7 kcal/kg/day for patients aged less than 60 years, or with non-diabetes, and 26.2 kcal/kg/day for patients aged 60 years and above, or with diabetes, respectively. The likelihood of the MetS increased with lower percentiles of energy intake in hemodialysis patients. In the multivariate analysis, the inadequate dietary energy intake strongly determined 3.24 folds of the MetS. The assessment of dietary EI can help healthcare providers detecting patients who are at risk of metabolic syndrome. PMID:29538427

  11. Engineering the Oryza sativa cell wall with rice NAC transcription factors regulating secondary wall formation

    Directory of Open Access Journals (Sweden)

    Kouki eYoshida

    2013-10-01

    Full Text Available Plant tissues that require structural rigidity synthesize a thick, strong secondary cell wall of lignin, cellulose and hemicelluloses in a complicated bridged structure. Master regulators of secondary wall synthesis were identified in dicots, and orthologs of these regulators have been identified in monocots, but regulation of secondary cell wall formation in monocots has not been extensively studied. Here we demonstrate that the rice transcription factors SECONDARY WALL NAC DOMAIN PROTEINs (SWNs can regulate secondary wall formation in rice (Oryza sativa and are potentially useful for engineering the monocot cell wall. The OsSWN1 promoter is highly active in sclerenchymatous cells of the leaf blade and less active in xylem cells. By contrast, the OsSWN2 promoter is highly active in xylem cells and less active in sclerenchymatous cells. OsSWN2 splicing variants encode two proteins; the shorter protein (OsSWN2S has very low transcriptional activation ability, but the longer protein (OsSWN2L and OsSWN1 have strong transcriptional activation ability. In rice, expression of an OsSWN2S chimeric repressor, driven by the OsSWN2 promoter, resulted in stunted growth and para-wilting (leaf rolling and browning under normal water conditions due to impaired vascular vessels. The same OsSWN2S chimeric repressor, driven by the OsSWN1 promoter, caused a reduction of cell wall thickening in sclerenchymatous cells, a drooping leaf phenotype, reduced lignin and xylose contents and increased digestibility as forage. These data suggest that OsSWNs regulate secondary wall formation in rice and manipulation of OsSWNs may enable improvements in monocotyledonous crops for forage or biofuel applications.

  12. Hydrodynamics of ultra-relativistic bubble walls

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Leonardo, E-mail: lleitao@mdp.edu.ar; Mégevand, Ariel, E-mail: megevand@mdp.edu.ar

    2016-04-15

    In cosmological first-order phase transitions, gravitational waves are generated by the collisions of bubble walls and by the bulk motions caused in the fluid. A sizeable signal may result from fast-moving walls. In this work we study the hydrodynamics associated to the fastest propagation modes, namely, ultra-relativistic detonations and runaway solutions. We compute the energy injected by the phase transition into the fluid and the energy which accumulates in the bubble walls. We provide analytic approximations and fits as functions of the net force acting on the wall, which can be readily evaluated for specific models. We also study the back-reaction of hydrodynamics on the wall motion, and we discuss the extrapolation of the friction force away from the ultra-relativistic limit. We use these results to estimate the gravitational wave signal from detonations and runaway walls.

  13. Validation of a cutoff point for the short version of the Depression Scale of the Center for Epidemiologic Studies in older Mexican adults

    Directory of Open Access Journals (Sweden)

    Aarón Salinas-Rodríguez

    2014-05-01

    Full Text Available Objective. To identify a valid cutoff point associated with Center for Epidemiologic Studies, Depression Scale (CES-D of seven items, which allows the classification of older adults according to presence/absence of clinically significant depressive symptoms. Materials and methods. Screening study with 229 older adults residing in two states of Mexico (Morelos and Tlaxcala, which were part of the sample from the National Survey of Health and Nutrition, 2012. We estimated the sensitivity and specificity associated with the selected cutoff points using the diagnostic criteria of ICD-10 (International Classification of Diseases, 10th revision and DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, fourth edition. Results. The cutoff point estimated was CES-D=5. According to the ICD-10 sensitivity and specificity were 83.3 and 90.2%, and ROC was 87%. Using DSM-IV, the values were 85, 83.2, and 84%, respectively. Conclusions. The short version of the CES-D can be used as a screening test to identify probable cases of older adults with clinically significant depressive symptoms.

  14. The Optimal Cut-Off Value of Neutrophil-to-Lymphocyte Ratio for Predicting Prognosis in Adult Patients with Henoch–Schönlein Purpura

    Science.gov (United States)

    Park, Chan Hyuk; Han, Dong Soo; Jeong, Jae Yoon; Eun, Chang Soo; Yoo, Kyo-Sang; Jeon, Yong Cheol; Sohn, Joo Hyun

    2016-01-01

    Background The development of gastrointestinal (GI) bleeding and end-stage renal disease (ESRD) can be a concern in the management of Henoch–Schönlein purpura (HSP). We aimed to evaluate whether the neutrophil-to-lymphocyte ratio (NLR) is associated with the prognosis of adult patients with HSP. Methods Clinical data including the NLR of adult patients with HSP were retrospectively analyzed. Patients were classified into three groups as follows: (a) simple recovery, (b) wax & wane without GI bleeding, and (c) development of GI bleeding. The optimal cut-off value was determined using a receiver operating characteristics curve and the Youden index. Results A total of 66 adult patients were enrolled. The NLR was higher in the GI bleeding group than in the simple recovery or wax & wane group (simple recovery vs. wax & wane vs. GI bleeding; median [IQR], 2.32 [1.61–3.11] vs. 3.18 [2.16–3.71] vs. 7.52 [4.91–10.23], P<0.001). For the purpose of predicting simple recovery, the optimal cut-off value of NLR was 3.18, and the sensitivity and specificity were 74.1% and 75.0%, respectively. For predicting development of GI bleeding, the optimal cut-off value was 3.90 and the sensitivity and specificity were 87.5% and 88.6%, respectively. Conclusions The NLR is useful for predicting development of GI bleeding as well as simple recovery without symptom relapse. Two different cut-off values of NLR, 3.18 for predicting an easy recovery without symptom relapse and 3.90 for predicting GI bleeding can be used in adult patients with HSP. PMID:27073884

  15. Diverse effects of distance cutoff and residue interval on the performance of distance-dependent atom-pair potential in protein structure prediction.

    Science.gov (United States)

    Yao, Yuangen; Gui, Rong; Liu, Quan; Yi, Ming; Deng, Haiyou

    2017-12-08

    As one of the most successful knowledge-based energy functions, the distance-dependent atom-pair potential is widely used in all aspects of protein structure prediction, including conformational search, model refinement, and model assessment. During the last two decades, great efforts have been made to improve the reference state of the potential, while other factors that also strongly affect the performance of the potential have been relatively less investigated. Based on different distance cutoffs (from 5 to 22 Å) and residue intervals (from 0 to 15) as well as six different reference states, we constructed a series of distance-dependent atom-pair potentials and tested them on several groups of structural decoy sets collected from diverse sources. A comprehensive investigation has been performed to clarify the effects of distance cutoff and residue interval on the potential's performance. Our results provide a new perspective as well as a practical guidance for optimizing distance-dependent statistical potentials. The optimal distance cutoff and residue interval are highly related with the reference state that the potential is based on, the measurements of the potential's performance, and the decoy sets that the potential is applied to. The performance of distance-dependent statistical potential can be significantly improved when the best statistical parameters for the specific application environment are adopted.

  16. Molecular regulation of plant cell wall extensibility

    Science.gov (United States)

    Cosgrove, D. J.

    1998-01-01

    Gravity responses in plants often involve spatial and temporal changes in cell growth, which is regulated primarily by controlling the ability of the cell wall to extend. The wall is thought to be a cellulose-hemicellulose network embedded in a hydrated matrix of complex polysaccharides and a small amount of structural protein. The wall extends by a form of polymer creep, which is mediated by expansins, a novel group of wall-loosening proteins. Expansins were discovered during a molecular dissection of the "acid growth" behavior of cell walls. Expansin alters the rheology of plant walls in profound ways, yet its molecular mechanism of action is still uncertain. It lacks detectable hydrolytic activity against the major components of the wall, but it is able to disrupt noncovalent adhesion between wall polysaccharides. The discovery of a second family of expansins (beta-expansins) sheds light on the biological role of a major group of pollen allergens and implies that expansins have evolved for diverse developmental functions. Finally, the contribution of other processes to wall extensibility is briefly summarized.

  17. A Review of Double-Walled and Triple-Walled Carbon Nanotube Synthesis and Applications

    Directory of Open Access Journals (Sweden)

    Kazunori Fujisawa

    2016-04-01

    Full Text Available Double- and triple-walled carbon nanotubes (DWNTs and TWNTs consist of coaxially-nested two and three single-walled carbon nanotubes (SWNTs. They act as the geometrical bridge between SWNTs and multi-walled carbon nanotubes (MWNTs, providing an ideal model for studying the coupling interactions between different shells in MWNTs. Within this context, this article comprehensively reviews various synthetic routes of DWNTs’ and TWNTs’ production, such as arc discharge, catalytic chemical vapor deposition and thermal annealing of pea pods (i.e., SWNTs encapsulating fullerenes. Their structural features, as well as promising applications and future perspectives are also discussed.

  18. The practicality of defensive ice walls: How would the great ice wall in Game of Thrones hold up?

    Science.gov (United States)

    Truffer, M.

    2017-12-01

    The Game of Thrones great ice wall is a colossal feature stretching several hundred miles and over 200 m high. Its purpose is to defend the realm from the wildlings. It is generally pictured as a near vertical wall. An ice wall of these proportions poses interesting challenges, mainly because ice acts as a non-linear shear-thinning fluid. A 200 m high vertical wall would create a large effective stress near its base of almost 1.8 MPa. Typical stresses responsible for ice flow in glaciers and ice sheets are more than a magnitude lower (0.1 MPa). Extrapolating a commonly used flow law for temperate ice to such high stresses would lead to strain rates at the bottom of the wall in excess of 1/day, meaning the wall would rapidly collapse and spread laterally under its own weight. To keep the wall stable, it would help to cool it significantly, as the flow of ice is also very temperature dependent. Cooling to a chilly -40 C would reduce strain rates by two orders of magnitude, but this still leads to significant slumping of the wall within just a few weeks. A time-dependent similarity solution for simplified ice flow equations that describe the evolving shape of the ice wall was provided by Halfar (1981), and demonstrates the rapid decay of the wall. A simple estimate can be derived by assuming that ice is a perfectly plastic fluid, able to maintain a basal shear stress of about 0.1 MPa. A stable ice wall would then spread laterally to about 4 km width. The resulting slope would only be steep at the very margin and the ice wall would loose much of its defensive capabilities. I conclude that the ice wall as proposed would not be a practicable defense under typical Earth conditions, and special magical powers would be necessary to maintain its shape, even for just a few days.

  19. The cell wall of Fusarium oxysporum

    NARCIS (Netherlands)

    Schoffelmeer, EAM; Klis, FM; Sietsma, JH; Cornelissen, BJC

    1999-01-01

    Sugar analysis of isolated cell walls from three formae speciales of Fusarium oxysporum showed that they contained not only glucose and (N-acetyl)-glucosamine, but also mannose, galactose, and uronic acids, presumably originating from cell wall glycoproteins. Cell wall glycoproteins accounted for

  20. Characterization of the Sclerotinia sclerotiorum cell wall proteome.

    Science.gov (United States)

    Liu, Longzhou; Free, Stephen J

    2016-08-01

    We used a proteomic analysis to identify cell wall proteins released from Sclerotinia sclerotiorum hyphal and sclerotial cell walls via a trifluoromethanesulfonic acid (TFMS) digestion. Cell walls from hyphae grown in Vogel's glucose medium (a synthetic medium lacking plant materials), from hyphae grown in potato dextrose broth and from sclerotia produced on potato dextrose agar were used in the analysis. Under the conditions used, TFMS digests the glycosidic linkages in the cell walls to release intact cell wall proteins. The analysis identified 24 glycosylphosphatidylinositol (GPI)-anchored cell wall proteins and 30 non-GPI-anchored cell wall proteins. We found that the cell walls contained an array of cell wall biosynthetic enzymes similar to those found in the cell walls of other fungi. When comparing the proteins in hyphal cell walls grown in potato dextrose broth with those in hyphal cell walls grown in the absence of plant material, it was found that a core group of cell wall biosynthetic proteins and some proteins associated with pathogenicity (secreted cellulases, pectin lyases, glucosidases and proteases) were expressed in both types of hyphae. The hyphae grown in potato dextrose broth contained a number of additional proteins (laccases, oxalate decarboxylase, peroxidase, polysaccharide deacetylase and several proteins unique to Sclerotinia and Botrytis) that might facilitate growth on a plant host. A comparison of the proteins in the sclerotial cell wall with the proteins in the hyphal cell wall demonstrated that sclerotia formation is not marked by a major shift in the composition of cell wall protein. We found that the S. sclerotiorum cell walls contained 11 cell wall proteins that were encoded only in Sclerotinia and Botrytis genomes. © 2015 The Authors. Molecular Plant Pathology published by British Society for Plant Pathology and John Wiley & Sons Ltd.

  1. Prognostic impact of proliferation for resected early stage 'pure' invasive lobular breast cancer: Cut-off analysis of Ki67 according to histology and clinical validation.

    Science.gov (United States)

    Carbognin, Luisa; Sperduti, Isabella; Fabi, Alessandra; Dieci, Maria Vittoria; Kadrija, Dzenete; Griguolo, Gaia; Pilotto, Sara; Guarneri, Valentina; Zampiva, Ilaria; Brunelli, Matteo; Orvieto, Enrico; Nortilli, Rolando; Fiorio, Elena; Parolin, Veronica; Manfrin, Erminia; Caliò, Anna; Nisticò, Cecilia; Pellini, Francesca; Scarpa, Aldo; Pollini, Giovanni Paolo; Conte, Pierfranco; Tortora, Giampaolo; Bria, Emilio

    2017-10-01

    The intent of this analysis was to investigate and validate the prognostic potential of Ki67 in a multi-center series of patients affected by early stage 'pure' invasive lobular carcinoma (ILC). Clinical-pathological data of patients affected by ILC were correlated with overall survival and disease-free survival (OS/DFS); data from a parallel invasive ductal carcinoma (IDC) patients' cohort were gathered as well. The maximally selected Log-Rank statistics analysis was applied to Ki67 continuous variable to estimate the appropriate cut-off. The Subpopulation Treatment Effect Pattern Plot (STEPP) analysis was performed as well. Data from overall 1097 (457/222 ILC: training/validation set; 418 IDC) patients were gathered. The identified optimal Ki67 cut-offs were 4% and 14% for DFS in ILC and IDC cohort, respectively. In ILC patients, the Ki67 cut-off was an independent OS predictor. Ten-years OS and DFS were 89.9% and 77.2% (p = 0.007) and 79.4% and 69.2% (p = 0.03) for patients with Ki67 ≤ 4% and >4%, respectively. In IDC patients, 10-years OS was 93.8% and 71.7%, p = 0.02, DFS was 84.0% and 52.6%, p = 0.0003, for patients with Ki67 ≤ 14% and >14%, respectively. In the validation set, the optimal Ki67 OS cut-off was 5%. The STEPP analysis showed that in the presence of low Ki67 values, IDC patients have a better DFS than ILC patients, while with the increase of values the prognosis tends to overlap. Despite the retrospective design of the study, the prognostic relevance of Ki67 (as well as its optimal cut-off) seems to significantly differ according to breast cancer histology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Hydrodynamics of ultra-relativistic bubble walls

    Directory of Open Access Journals (Sweden)

    Leonardo Leitao

    2016-04-01

    Full Text Available In cosmological first-order phase transitions, gravitational waves are generated by the collisions of bubble walls and by the bulk motions caused in the fluid. A sizeable signal may result from fast-moving walls. In this work we study the hydrodynamics associated to the fastest propagation modes, namely, ultra-relativistic detonations and runaway solutions. We compute the energy injected by the phase transition into the fluid and the energy which accumulates in the bubble walls. We provide analytic approximations and fits as functions of the net force acting on the wall, which can be readily evaluated for specific models. We also study the back-reaction of hydrodynamics on the wall motion, and we discuss the extrapolation of the friction force away from the ultra-relativistic limit. We use these results to estimate the gravitational wave signal from detonations and runaway walls.

  3. Third molar cut-off value in assessing the legal age of 18 in Saudi population.

    Science.gov (United States)

    AlQahtani, Sakher; Kawthar, Alemad; AlAraik, Ayman; AlShalan, Ahmad

    2017-03-01

    Teeth plays a major role in forensic sciences especially in age assessment of an individual, which can be used to aid in criminal or civil matters. The importance of teeth comes from their ability to survive inhumation well and because they are hardly affected by exogenous and endogenous factors. Third molars are the only teeth still developing after the age of 14 years and during the legal age of adulthood, which is 18 years. The consequences of criminal violation can strongly affect the individual's life, it is important to set different parameters to decide whether an individual is a minor or an adult in the absence of documents. Depending on the different legal requirement, such parameters can set above 90% probability for criminal matters and from 51% to civil matters. The aim of this research was to find the cut-off value of third molar development for the legal age of 18 amongst Saudi individuals using the third molar maturity index method by Cameriere et al. (2008) [17]. This was a cross sectional study on 300 archived orthopantomogram (OPG) of healthy Saudi patients between the ages 14 and 22 years attending the Dental Hospital at King Saud University, Riyadh, Saudi Arabia. All OPGs were taken by PLANMECA - ProMax machine and evaluated by the Romaxis software. The inclusion criteria were good quality OPGs taken during the course of treatment. All patients were healthy with no systemic diseases or disorders with the presence of third molars and clear root apex. The lower left mandibular third molar (LL3rdM) was assessed using third molar maturity index (I3m) to determine if the individual is younger or older than 18 years old. The cut-off value of I3m for the Saudi population was (I3mage of adulthood in Saudi population and the cut-off value of I3m is similar to other populations. Although dental age assessment by means of third molar development is useful, it still has its limitation because of its variation in position, morphology and development

  4. Nonsingular walls in plane cholesteric layers

    International Nuclear Information System (INIS)

    Belyakov, V A; Osipov, M A; Stewart, I W

    2006-01-01

    The structure of a straight interface (wall) between regions with differing values of the pitch in planar cholesteric layers with finite strength of the surface anchoring is investigated theoretically. It is found that the shape and strength of the anchoring potential influences essentially the structure of the wall and a motionless wall between thermodynamically stable regions without a singularity in the director distribution in the layer can exist for sufficiently weak anchoring only. More specifically, for the existence of such a wall the dimensionless parameter S d = K 22 /Wd (where W is the depth of the anchoring potential, K 22 is the elastic twist modulus and d is the layer thickness) should exceed its critical value, which is dependent on the shape of the anchoring potential. General equations describing the director distribution in the wall are presented. Detailed analysis of these equations is carried out for the case of infinitely strong anchoring at one surface and finite anchoring strength at the second layer surface. It is shown that the wall width L is directly dependent upon the shape and strength of the anchoring potential and that its estimate ranges from d to (dL p ) 1/2 (where L p = K 22 /W is the penetration length), corresponding to different anchoring strengths and shape potentials. The dependence of the director distribution in the wall upon all three Frank elastic moduli is analytically found for some specific limiting cases of the model anchoring potentials. Motion of the wall is briefly investigated and the corresponding calculations performed under the assumption that the shape of a moving wall is the same as a motionless one. It is noted that experimental investigation of the walls in planar cholesteric layers can be used for the determination of the actual shape of surface anchoring potentials

  5. Immersion Refractometry of Isolated Bacterial Cell Walls

    Science.gov (United States)

    Marquis, Robert E.

    1973-01-01

    Immersion-refractometric and light-scattering measurements were adapted to determinations of average refractive indices and physical compactness of isolated bacterial cell walls. The structures were immersed in solutions containing various concentrations of polymer molecules that cannot penetrate into wall pores, and then an estimate was made of the polymer concentration or the refractive index of the polymer solution in which light scattering was reduced to zero. Because each wall preparation was heterogeneous, the refractive index of the medium for zero light scattering had to be estimated by extrapolation. Refractive indices for walls suspended in bovine serum albumin solutions ranged from 1.348 for walls of the rod form of Arthrobacter crystallopoietes to 1.382 for walls of the teichoic acid deficient, 52A5 strain of Staphylococcus aureus. These indices were used to calculate approximate values for solids content per milliliter, and the calculated values agreed closely with those estimated from a knowledge of dextran-impermeable volumes per gram, dry weight, of the walls. When large molecules such as dextrans or serum albumin were used for immersion refractometry, the refractive indices obtained were for entire walls, including both wall polymers and wall water. When smaller molecules that can penetrate wall pores to various extents were used with Micrococcus lysodeikticus walls, the average, apparent refractive index of the structures increased as the molecular size of probing molecules was decreased. It was possible to obtain an estimate of 1.45 to 1.46 for the refractive index of wall polymers, predominantly peptidoglycans in this case, by extrapolating the curve for refractive index versus molecular radius to a value of 0.2 nm, the approximate radius of a water molecule. This relatively low value for polymer refractive index was interpreted as evidence in favor of the amorphous, elastic model of peptidoglycan structure and against the crystalline, rigid

  6. Distribution of Ωk from the scale-factor cutoff measure

    International Nuclear Information System (INIS)

    De Simone, Andrea; Salem, Michael P.

    2010-01-01

    Our Universe may be contained in one among a diverging number of bubbles that nucleate within an eternally inflating multiverse. A promising measure to regulate the diverging spacetime volume of such a multiverse is the scale-factor cutoff, one feature of which is bubbles are not rewarded for having a longer duration of slow-roll inflation. Thus, depending on the landscape distribution of the number of e-folds of inflation among bubbles like ours, we might hope to measure spatial curvature. We study a recently proposed cartoon model of inflation in the landscape and find a reasonable chance (about 10%) that the curvature in our Universe is well above the value expected from cosmic variance. Anthropic selection does not strongly select for curvature as small as is observed (relative somewhat larger values), meaning the observational bound on curvature can be used to rule out landscape models that typically give too little inflation.

  7. Wall motion abnormality of myocardial infarction

    International Nuclear Information System (INIS)

    Hayashi, Senji; Tsuda, Takashi; Ojima, Kenji

    1984-01-01

    By use of the gated blood pool scan, we divided the left ventricular LAO 45 image into 8 sections with the center of the volume as the basal point, and devised a method of quantitative evaluation of the regional wall motion from 2 aspects: 1) wall movement and 2) phase abnormality. To evaluate the wall movement, we obtained the following indeces from count curves of each section: 1) EF1=(end-diastolic count-end-systolic count)/ end-diastolic count, 2) EF2=(maximum count-minimum count)/maximum count, and 3) the difference of the two (EF2-EF1). As indeces of the phase abnormality, the mean value of phases of the pixels (phase characteristics) and the standard deviation (variation) of each section were calculated. Furthermore, the phase delay of each section was calculated as the difference from the earliest phase value of the 8 sections. Control values and standard deviation were obtained from 8 healthy controls. By this method, we analyzed 20 patients with old myocardial infarction. And following results were obtained: 1. Applying this method, we could evaluate the regional wall motion of the left ventricle more precisely, and we considered it would be useful clinically. 2. The abnormal regional wall motion of old myocardial infarction were classified into 4 typical forms as follows: 1) the wall movement decreased extremely. 2) the wall movement decreased, but no phase delay recognized. 3) the wall movement did not decrease, but phase delay was recognized. 4) the wall movement decreased, and phase delay was recognized. (author)

  8. The Role of Auxin in Cell Wall Expansion.

    Science.gov (United States)

    Majda, Mateusz; Robert, Stéphanie

    2018-03-22

    Plant cells are surrounded by cell walls, which are dynamic structures displaying a strictly regulated balance between rigidity and flexibility. Walls are fairly rigid to provide support and protection, but also extensible, to allow cell growth, which is triggered by a high intracellular turgor pressure. Wall properties regulate the differential growth of the cell, resulting in a diversity of cell sizes and shapes. The plant hormone auxin is well known to stimulate cell elongation via increasing wall extensibility. Auxin participates in the regulation of cell wall properties by inducing wall loosening. Here, we review what is known on cell wall property regulation by auxin. We focus particularly on the auxin role during cell expansion linked directly to cell wall modifications. We also analyze downstream targets of transcriptional auxin signaling, which are related to the cell wall and could be linked to acid growth and the action of wall-loosening proteins. All together, this update elucidates the connection between hormonal signaling and cell wall synthesis and deposition.

  9. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.

    Science.gov (United States)

    Kocer, Derya; Sarıguzel, Fatma M; Karakukcu, Cıgdem

    2014-08-01

    The microscopic analysis of urine is essential for the diagnosis of patients with urinary tract infections. Quantitative urine culture is the 'gold standard' method for definitive diagnosis of urinary-tract infections, but it is labor-intensive, time consuming, and does not provide the same-day results. The aim of this study was to evaluate the analytical and diagnostic performance of the FUS200 (Changchun Dirui Industry, China), a new urine sedimentation analyzer in comparison to urine culture as the reference method. We evaluated 1000 urine samples, submitted for culture and urine analysis with a preliminary diagnosis of urinary-tract infection. Cut-off values for the FUS200 were determined by comparing the results with urine cultures. The cut-off values by the receiver operating characteristic (ROC) curve technique, sensitivity, and specificity were calculated for bacteria and white blood cells (WBCs). Among the 1000 urine specimens submitted for culture, 637 cultures (63.7%) were negative, and 363 were (36.3%) positive. The best cut-off values obtained from ROC analysis were 16/μL for bacteriuria (sensitivity: 82.3%, specificity: 58%), and 34/μL for WBCs (sensitivity: 72.3%, specificity: 65.2%). The area under the curve (AUC) for the bacteria and WBCs count were 0.71 (95% CI: 0.67-0.74) and, 0.72 (95% CI: 0.69-0.76) respectively. The most important requirement of a rapid diagnostic screening test is sensitivity, and, in this perspective, an unsatisfactory sensitivity by using bacteria recognition and quantification performed by the FUS200 analyzer has been observed. After further technical improvements in particle recognition and laboratory personnel training, the FUS200 might show better results.

  10. 2003 Plant Cell Walls Gordon Conference

    Energy Technology Data Exchange (ETDEWEB)

    Daniel J. Cosgrove

    2004-09-21

    This conference will address recent progress in many aspects of cell wall biology. Molecular, genetic, and genomic approaches are yielding major advances in our understanding of the composition, synthesis, and architecture of plant cell walls and their dynamics during growth, and are identifying the genes that encode the machinery needed to make their biogenesis possible. This meeting will bring together international scientists from academia, industry and government labs to share the latest breakthroughs and perspectives on polysaccharide biosynthesis, wood formation, wall modification, expansion and interaction with other organisms, and genomic & evolutionary analyses of wall-related genes, as well as to discuss recent ''nanotechnological'' advances that take wall analysis to the level of a single cell.

  11. Wall Finishes; Carpentry: 901895.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    The course outline is designed to provide instruction in selecting, preparing, and installing wall finishing materials. Prerequisites for the course include mastery of building construction plans, foundations and walls, and basic mathematics. Intended for use in grades 11 and 12, the course contains five blocks of study totaling 135 hours of…

  12. To detect anomalies in diaphragm walls

    NARCIS (Netherlands)

    Spruit, R.

    2015-01-01

    Diaphragm walls are potentially ideal retaining walls for deep excavations in densely built-up areas, as they cause no vibrations during their construction and provide structural elements with high strength and stiffness. In the recent past, however, several projects using diaphragm walls as soil

  13. Performance tests of an abrasive cut-off systems for the finishing of high-precision casts

    OpenAIRE

    A. Fedoryszyn; W. T. Meksa; G. Woźnicki

    2008-01-01

    The paper summarizes the performance data of a newly designed and engineered grinding and cut-off system. The machine is used for separation of models manufactured by the investment casting method. The machine comprises the following units:- base supporting other assemblies and elements: abrasive disc holder and drives; this solution enables an easy replacement and access to holding elements while a belt transmission allows the disc rpm to be varied,- mechanism moving the spindle in the horiz...

  14. Strain-Encoded Cardiac Magnetic Resonance Imaging as an Adjunct for Dobutamine Stress Testing. Incremental Value to Conventional Wall Motion Analysis

    Science.gov (United States)

    Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A.; Osman, Nael F.

    2009-01-01

    Background High-dose dobutamine stress magnetic resonance imaging (DS-MRI) is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, Strain-Encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC to that provided by conventional wall motion analysis for the detection of inducible ischemia during DS-MRI. Methods and Results Stress induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent DS-MRI in a clinical 1.5T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (≥50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86/101 versus 71/101 diseased coronary vessels (p<0.01 versus cine), and showed normal strain response in 189/202 versus 194/202 vessels with <50% stenosis (p=NS versus cine). On a patient level, SENC detected inducible ischemia in 63/64 versus 55/64 patients with CAD (p<0.05 versus cine), and showed normal strain response in 32/37 versus 34/37 patients without CAD (p=NS versus cine).Quantification analysis demonstrated a significant correlation between strain rate reserve (SRreserve) and coronary artery stenosis severity (r²=0.56, p<0.001), and a cut-off value of SRreserve=1.64 deemed as a highly accurate marker for the detection of stenosis≥50% (AUC=0.96, SE=0.01, 95% CI = 0.94–0.98, p<0.001). Conclusions The direct color-coded visualization of strain on MR-images is a useful adjunct for DS-MRI, which provides incremental value for the detection of CAD compared to conventional wall motion readings on cine images. PMID:19808579

  15. Regeneration of near-wall turbulence structures

    Science.gov (United States)

    Hamilton, James M.; Kim, John J.; Waleffe, Fabian A.

    1993-01-01

    An examination of the regeneration mechanisms of near-wall turbulence and an attempt to investigate the critical Reynolds number conjecture of Waleffe & Kim is presented. The basis is an extension of the 'minimal channel' approach of Jimenez and Moin which emphasizes the near-wall region and further reduces the complexity of the turbulent flow. Reduction of the flow Reynolds number to the minimum value which will allow turbulence to be sustained has the effect of reducing the ratio of the largest scales to the smallest scales or, equivalently, of causing the near-wall region to fill more of the area between the channel walls. In addition, since each wall may have an active near-wall region, half of the channel is always somewhat redundant. If a plane Couette flow is instead chosen as the base flow, this redundancy is eliminated: the mean shear of a plane Couette flow has a single sign, and at low Reynolds numbers, the two wall regions share a single set of structures. A minimal flow with these modifications possesses, by construction, the strongest constraints which allow sustained turbulence, producing a greatly simplified flow in which the regeneration process can be examined.

  16. Ordinary mode reflectometry. Modification of the scattering and cut-off responses due to the shape of localized density fluctuations

    International Nuclear Information System (INIS)

    Fanack, C.; Boucher, I.; Heuraux, S.; Leclert, G.; Clairet, F.; Zou, X.L.

    1996-01-01

    Ordinary wave reflectometry in a plasma containing a localized density perturbation is studied with a 1-D model. The phase response is studied as a function of the wavenumber and position of the perturbation. It is shown that it strongly depends upon the perturbation shape and size. For a small perturbation wavenumber, the response is due to the oscillation of the cut-off layer. For larger wavenumbers, two regimes are found: for a broad perturbation, the phase response is an image of the perturbation itself; for a narrow perturbation, it is rather an image of the Fourier transform. For tokamak plasmas it turns out that, for the fluctuation spectra usually observed, the phase response comes primarily from those fluctuations that are localized at the cut-off. Results of a 2-D numerical model show that geometry effects are negligible for the scattering by radial fluctuations. (author)

  17. Reduced Wall Acetylation Proteins Play Vital and Distinct Roles in Cell Wall O-Acetylation in Arabidopsis

    DEFF Research Database (Denmark)

    Manabe, Yuzuki; Verhertbruggen, Yves; Gille, Sascha

    2013-01-01

    The Reduced Wall Acetylation (RWA) proteins are involved in cell wall acetylation in plants. Previously, we described a single mutant, rwa2, which has about 20% lower level of O-acetylation in leaf cell walls and no obvious growth or developmental phenotype. In this study, we generated double....... The quadruple rwa mutant can be completely complemented with the RWA2 protein expressed under 35S promoter, indicating the functional redundancy of the RWA proteins. Nevertheless, the degree of acetylation of xylan, (gluco) mannan, and xyloglucan as well as overall cell wall acetylation is affected differently...... in different combinations of triple mutants, suggesting their diversity in substrate preference. The overall degree of wall acetylation in the rwa quadruple mutant was reduced by 63% compared with the wild type, and histochemical analysis of the rwa quadruple mutant stem indicates defects in cell...

  18. Gas Enrichment at Liquid-Wall Interfaces

    NARCIS (Netherlands)

    Dammer, S.M.; Lohse, Detlef

    2006-01-01

    Molecular dynamics simulations of Lennard-Jones systems are performed to study the effects of dissolved gas on liquid-wall and liquid-gas interfaces. Gas enrichment at walls, which for hydrophobic walls can exceed more than 2 orders of magnitude when compared to the gas density in the bulk liquid,

  19. Differentiation between polycystic ovary syndrome and polycystic ovarian morphology by means of an anti-Müllerian hormone cutoff value.

    Science.gov (United States)

    Song, Do Kyeong; Oh, Jee-Young; Lee, Hyejin; Sung, Yeon-Ah

    2017-07-01

    Although increased serum anti-Müllerian hormone (AMH) level has been suggested to be a surrogate marker of polycystic ovarian morphology (PCOM), its association with polycystic ovary syndrome (PCOS) is controversial, and its diagnostic value has not been determined. We aimed to observe the relationship between the AMH level and PCOS phenotypes and to determine the optimal cutoff value of AMH for the diagnosis of PCOS in young Korean women. We recruited 207 women with PCOS (120 with PCOM and 87 without PCOM) and 220 regular cycling women with normoandrogenemia (100 with PCOM and 120 without PCOM). Subjects underwent testing at a single outpatient visit. Serum AMH level was measured. Women with PCOS had higher serum AMH levels than did regular cycling women with normoandrogenemia ( p < 0.05). Women with PCOM had higher serum AMH levels than women without PCOM, regardless of PCOS status ( p < 0.05). The optimal AMH cutoff value for the diagnosis of PCOS was 10.0 ng/mL (71% sensitivity, 93% specificity). Serum AMH was an independent determinant of total testosterone after adjustment for age, body mass index, and the number of menses/year (β = 0.31, p < 0.01). An association between AMH and hyperandrogenism was only observed in women with PCOS, and it was independent of the presence of PCOM. The serum AMH level can be useful for the diagnosis of PCOS at any age less than 40 years, and the optimal cutoff value for the diagnosis of PCOS identified in this study of young Korean women was 10.0 ng/mL.

  20. Statistical analysis of silo wall pressures

    DEFF Research Database (Denmark)

    Ditlevsen, Ove Dalager; Berntsen, Kasper Nikolaj

    1998-01-01

    Previously published silo wall pressure measurements during plug flow of barley in alarge concrete silo are re-analysed under the hypothesis that the wall pressures are gamma-distributed.The fits of the gamma distribution type to the local pressure data from each measuring cell are satisfactory.......However, the estimated parameters of the gamma distributions turn out to be significantly inhomogeneous overthe silo wall surface. This inhomogeneity is attributed to the geometrical imperfections of the silo wall.Motivated by the engineering importance of the problem a mathematical model for constructing astochastic...... gamma-type continuous pressure field is given. The model obeys the necessary equilibrium conditionsof the wall pressure field and reflects the spatial correlation properties as estimated from simultaneouslymeasured pressures at different locations along a horizontal perimeter....

  1. Studies on first wall and plasma wall interaction in JT-60

    International Nuclear Information System (INIS)

    Nakamura, Hiroo

    1988-12-01

    This paper describes studies on first wall and plasma wall interaction in JT-60. Main results are as follows; (1) To select JT-60 first wall material, various RandD were done in FY1975 ∼ 1976. Mo was selected as first wall materials of limiters and divertor plates because of its reliability under a high heat flux condition. (2) Development of low-Z material has been done to reduce impurity problem of Mo first wall. As a result, titanium carbide (TiC) was selected as a coating material on the Mo. High heat load testing has been done for TiC coated Mo limiter same as JT-60. This material can survive under the condition of 1 kW/cm 2 x 10 s, expected in JT-60 limiter design. (3) To reduce high heat load on the divertor plate, separatrix swing is proposed. Optimum frequency of the sweeping is evaluated to be 2 Hz in JT-60. For a discharge with heating power of 30 MW and duration time of 10 s, in addition to the separatrix swing, remote radiative cooling in the divertor region is necessary. Moreover, calculations of erosion thickness have been done for stainless steel, Mo, graphite, TiC and silicon caibide under high heat flux during plasma disruption. (4) In divertor experiments in JT-60, divertor functions on particle, heat load and impurity controls have been demonstrated. In elctron density of 6 x 10 19 m -3 , particle fueling rate of 20 MW NB heating (3 Pa m 3 /s) can be exhausted by divertor pumping system. Effectiveness of remote radiative cooling is demonstrated under the condition of 20 MW NB heating power. Also, separatrix swing is demonstrated to reduce heat load on the divertor plate. Total radiation in main plasma is 5 ∼ 10% of total absorbed power. (author) 120 refs

  2. Dynamics of strings between walls

    International Nuclear Information System (INIS)

    Eto, Minoru; Fujimori, Toshiaki; Nagashima, Takayuki; Nitta, Muneto; Ohashi, Keisuke; Sakai, Norisuke

    2009-01-01

    Configurations of vortex strings stretched between or ending on domain walls were previously found to be 1/4 Bogomol'nyi-Prasad-Sommerfield (BPS) states in N=2 supersymmetric gauge theories in 3+1 dimensions. Among zero modes of string positions, the center of mass of strings in each region between two adjacent domain walls is shown to be non-normalizable whereas the rests are normalizable. We study dynamics of vortex strings stretched between separated domain walls by using two methods, the moduli space (geodesic) approximation of full 1/4 BPS states and the charged particle approximation for string end points in the wall effective action. In the first method we explicitly obtain the effective Lagrangian in the strong coupling limit, which is written in terms of hypergeometric functions, and find the 90 deg. scattering for head-on collision. In the second method the domain wall effective action is assumed to be U(1) N gauge theory, and we find a good agreement between two methods for well-separated strings.

  3. Isolation of the Cell Wall.

    Science.gov (United States)

    Canut, Hervé; Albenne, Cécile; Jamet, Elisabeth

    2017-01-01

    This chapter describes a method allowing the purification of the cell wall for studying both polysaccharides and proteins. The plant primary cell wall is mainly composed of polysaccharides (90-95 % in mass) and of proteins (5-10 %). At the end of growth, specialized cells may synthesize a lignified secondary wall composed of polysaccharides (about 65 %) and lignin (about 35 %). Due to its composition, the cell wall is the cellular compartment having the highest density and this property is used for its purification. It plays critical roles during plant development and in response to environmental constraints. It is largely used in the food and textile industries as well as for the production of bioenergy. All these characteristics and uses explain why its study as a true cell compartment is of high interest. The proposed method of purification can be used for large amount of material but can also be downscaled to 500 mg of fresh material. Tools for checking the quality of the cell wall preparation, such as protein analysis and microscopy observation, are also provided.

  4. Wall Construction; Carpentry: 901892.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    The curriculum guide outlines a course designed to provide instruction in floor and wall layout, and in the diverse methods and construction of walls. Upon completion of this course the students should have acquired a knowledge of construction plans and structural foundations in addition to a basic knowledge of mathematics. The course consists of…

  5. From Newton's Law to the Linear Boltzmann Equation Without Cut-Off

    Science.gov (United States)

    Ayi, Nathalie

    2017-03-01

    We provide a rigorous derivation of the linear Boltzmann equation without cut-off starting from a system of particles interacting via a potential with infinite range as the number of particles N goes to infinity under the Boltzmann-Grad scaling. More particularly, we will describe the motion of a tagged particle in a gas close to global equilibrium. The main difficulty in our context is that, due to the infinite range of the potential, a non-integrable singularity appears in the angular collision kernel, making no longer valid the single-use of Lanford's strategy. Our proof relies then on a combination of Lanford's strategy, of tools developed recently by Bodineau, Gallagher and Saint-Raymond to study the collision process, and of new duality arguments to study the additional terms associated with the long-range interaction, leading to some explicit weak estimates.

  6. Optimizing cutoff scores for the Barthel Index and the modified Rankin Scale for defining outcome in acute stroke trials

    NARCIS (Netherlands)

    Uyttenboogaart, Maarten; Stewart, Roy E; Vroomen, Patrick C A J; De Keyser, Jacques; Luijckx, Gert-Jan

    Background and Purpose - There is little agreement on how to assess outcome in acute stroke trials. Cutoff scores for the Barthel Index (BI) and modified Rankin Scale (mRS) are frequently arbitrarily chosen to dichotomize favorable and unfavorable outcome. We investigated sensitivity and specificity

  7. Cut-off effect of radical TEMPO derivatives in olive oil-in-water emulsions.

    Science.gov (United States)

    Lopez de Arbina, Amaia; Rezende, Marcos Caroli; Aliaga, Carolina

    2017-06-01

    Three oil-in-water emulsions were prepared from mixtures of olive oil and Tween 20 in water. The effectiveness of a series of radical 2,2,6,6-tetramethylpiperidinoxyl (TEMPO) derivatives of variable lipophilicity in reactions with antioxidant Trolox, and as pyrene-fluorescence quenchers, was compared in the three emulsions. A "cut-off" effect was observed for the pyrene quenching by the probes, but not for their reaction with Trolox. The results were rationalized in terms of the amphiphobic nature of the probes, and the different locations of probe, pyrene and Trolox in the three-phase microheterogeneous systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Space-time foam effects on particle interactions and the Greisen-Zatsepin-Kuzmin cutoff

    International Nuclear Information System (INIS)

    Ellis, John; Mavromatos, N. E.; Nanopoulos, D. V.

    2001-01-01

    Modeling space-time foam using a noncritical Liouville-string model for the quantum fluctuations of D-branes with recoil, we discuss the issues of momentum and energy conservation in particle propagation and interactions. We argue that momentum should be conserved exactly during propagation and on the average during interactions, but that energy is conserved only on the average during propagation and is in general not conserved during particle interactions, because of changes in the background metric. We discuss the possible modification of the GZK cutoff on high-energy cosmic rays, in the light of this energy non-conservation as well as the possible modification of the usual relativistic momentum-energy relation

  9. Prospects for a fissile material cut-off: Achieving a successful NPT review process

    International Nuclear Information System (INIS)

    Kalinowski, M.

    1999-01-01

    Finding new and creative ways to overcome the current deadlock in progress in nuclear arms control became the most important question in the past year. For a long time it had been expected that after the conclusion of the Comprehensive Test Ban Treaty, the next step would be to ban production of fissile materials for weapon purposes. Three strategies are proposed for reaching relevant cut-off agreements. First suggests possible fore for achievement of relevant agreements, second is the proposal to begin with international register of inventories and production capabilities for all relevant nuclear materials, and the third one is ti identify equivalent steps obligatory for all the parties involved

  10. Implementing Green Walls in Schools

    Directory of Open Access Journals (Sweden)

    Michael B. McCullough

    2018-06-01

    Full Text Available Numerous studies in applied pedagogical design have shown that, at all educational levels, direct exposure to the natural environment can enhance learning by improving student attention and behaviors. Implementing green walls—a “vertical garden,” or “living wall” interior wall that typically includes greenery, a growing medium (soil or substrate and a water delivery system—provides environmental health benefits, but also provides a practical application within classrooms for minimizing directed attention fatigue in students by connecting them to “outdoor nature” within the indoor environment. Hands-on “project-based” learning is another pedagogical strategy that has proved to be effective across the spectrum of educational levels and across subject areas. Green walls have the potential to inspire critical thinking through a combination of project-based learning strategies and environmental education. The authors have outlined a curriculum involving the implementation of an indoor living wall system within a classroom-learning environment, incorporating project-based learning modules that interact with the wall. In conjunction with the passive health benefits of a green wall, project-based curriculum models can connect students interactively with indoor nature and have the potential to inspire real-world thinking related to science, technology, engineering, art, and mathematics fields within the indoor learning environment. Through a combination of these passive and interactive modes, students are connected to nature in the indoor environment regardless of weather conditions outdoors. Future research direction could include post-construction studies of the effectiveness of project-based curricula related to living walls, and the long-term impacts of implementing green walls in classrooms on school achievement and student behaviors.

  11. Results obtained during wall breaching research

    CSIR Research Space (South Africa)

    Hattingh, S

    2008-11-01

    Full Text Available To understand the physics of what is happening inside the wall directly after the detonation and the application of this knowledge in the improvement of the charge Measure the shock/stress waves in the masonry material and then in the wall as a whole... to maximise the effect of the charges on the walls and to broaden the knowledge of the physics of shock and stress waves. The thickness and characteristics of walls are not usually known in an operation. The effect of the charges on real buildings is still...

  12. Glycoprotein component of plant cell walls

    International Nuclear Information System (INIS)

    Cooper, J.B.; Chen, J.A.; Varner, J.E.

    1984-01-01

    The primary wall surrounding most dicotyledonous plant cells contains a hydroxyproline-rich glycoprotein (HRGP) component named extensin. A small group of glycopeptides solubilized from isolated cell walls by proteolysis contained a repeated pentapeptide glycosylated by tri- and tetraarabinosides linked to hydroxyproline and, by galactose, linked to serine. Recently, two complementary approaches to this problem have provided results which greatly increase the understanding of wall extensin. In this paper the authors describe what is known about the structure of soluble extensin secreted into the walls of the carrot root cells

  13. Evidence for a maximum mass cut-off in the neutron star mass distribution and constraints on the equation of state

    Science.gov (United States)

    Alsing, Justin; Silva, Hector O.; Berti, Emanuele

    2018-04-01

    We infer the mass distribution of neutron stars in binary systems using a flexible Gaussian mixture model and use Bayesian model selection to explore evidence for multi-modality and a sharp cut-off in the mass distribution. We find overwhelming evidence for a bimodal distribution, in agreement with previous literature, and report for the first time positive evidence for a sharp cut-off at a maximum neutron star mass. We measure the maximum mass to be 2.0M⊙ sharp cut-off is interpreted as the maximum stable neutron star mass allowed by the equation of state of dense matter, our measurement puts constraints on the equation of state. For a set of realistic equations of state that support >2M⊙ neutron stars, our inference of mmax is able to distinguish between models at odds ratios of up to 12: 1, whilst under a flexible piecewise polytropic equation of state model our maximum mass measurement improves constraints on the pressure at 3 - 7 × the nuclear saturation density by ˜30 - 50% compared to simply requiring mmax > 2M⊙. We obtain a lower bound on the maximum sound speed attained inside the neutron star of c_s^max > 0.63c (99.8%), ruling out c_s^max c/√{3} at high significance. Our constraints on the maximum neutron star mass strengthen the case for neutron star-neutron star mergers as the primary source of short gamma-ray bursts.

  14. Bacterial cell wall composition and the influence of antibiotics by cell-wall and whole-cell NMR

    Science.gov (United States)

    Romaniuk, Joseph A. H.; Cegelski, Lynette

    2015-01-01

    The ability to characterize bacterial cell-wall composition and structure is crucial to understanding the function of the bacterial cell wall, determining drug modes of action and developing new-generation therapeutics. Solid-state NMR has emerged as a powerful tool to quantify chemical composition and to map cell-wall architecture in bacteria and plants, even in the context of unperturbed intact whole cells. In this review, we discuss solid-state NMR approaches to define peptidoglycan composition and to characterize the modes of action of old and new antibiotics, focusing on examples in Staphylococcus aureus. We provide perspectives regarding the selected NMR strategies as we describe the exciting and still-developing cell-wall and whole-cell NMR toolkit. We also discuss specific discoveries regarding the modes of action of vancomycin analogues, including oritavancin, and briefly address the reconsideration of the killing action of β-lactam antibiotics. In such chemical genetics approaches, there is still much to be learned from perturbations enacted by cell-wall assembly inhibitors, and solid-state NMR approaches are poised to address questions of cell-wall composition and assembly in S. aureus and other organisms. PMID:26370936

  15. Mechanism of bubble detachment from vibrating walls

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongjun; Park, Jun Kwon, E-mail: junkeun@postech.ac.kr; Kang, Kwan Hyoung [Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); Kang, In Seok [Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of)

    2013-11-15

    We discovered a previously unobserved mechanism by which air bubbles detach from vibrating walls in glasses containing water. Chaotic oscillation and subsequent water jets appeared when a wall vibrated at greater than a critical level. Wave forms were developed at water-air interface of the bubble by the wall vibration, and water jets were formed when sufficiently grown wave-curvatures were collapsing. Droplets were pinched off from the tip of jets and fell to the surface of the glass. When the solid-air interface at the bubble-wall attachment point was completely covered with water, the bubble detached from the wall. The water jets were mainly generated by subharmonic waves and were generated most vigorously when the wall vibrated at the volume resonant frequency of the bubble. Bubbles of specific size can be removed by adjusting the frequency of the wall's vibration.

  16. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  17. A multicenter study on PIVKA reference interval of healthy population and establishment of PIVKA cutoff value for hepatocellular carcinoma diagnosis in China.

    Science.gov (United States)

    Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L

    2017-08-01

    The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.

  18. Appropriate body mass index cut-offs to determine thinness, overweight and obesity in South Asian children in The Netherlands

    NARCIS (Netherlands)

    Wilde, J.A. de; Dommelen, P. van; Middelkoop, B.J.C.

    2013-01-01

    Background: Asian populations have an increased risk of developing cardiometabolic disorders at a lower body mass index (BMI) than other ethnic groups. Therefore, lower adult BMI cut-offs to determine overweight and obesity are recommended to assess the associated health risks for Asian (23 and 27.5

  19. Evolution of the Stability Work from Classic Retaining Walls to Mechanically Stabilized Earth Walls

    Directory of Open Access Journals (Sweden)

    Anghel Stanciu

    2008-01-01

    Full Text Available For the consolidation of soil mass and the construction of the stability works for roads infrastructure it was studied the evolution of these kinds of works from classical retaining walls - common concrete retaining walls, to the utilization in our days of the modern and competitive methods - mechanically stabilized earth walls. Like type of execution the variety of the reinforced soil is given by the utilization of different types of reinforcing inclusions (steel strips, geosynthetics, geogrids or facing (precast concrete panels, dry cast modular blocks, metal sheets and plates, gabions, and wrapped sheets of geosynthetics.

  20. Estimation of bladder wall location in ultrasound images.

    Science.gov (United States)

    Topper, A K; Jernigan, M E

    1991-05-01

    A method of automatically estimating the location of the bladder wall in ultrasound images is proposed. Obtaining this estimate is intended to be the first stage in the development of an automatic bladder volume calculation system. The first step in the bladder wall estimation scheme involves globally processing the images using standard image processing techniques to highlight the bladder wall. Separate processing sequences are required to highlight the anterior bladder wall and the posterior bladder wall. The sequence to highlight the anterior bladder wall involves Gaussian smoothing and second differencing followed by zero-crossing detection. Median filtering followed by thresholding and gradient detection is used to highlight as much of the rest of the bladder wall as was visible in the original images. Then a 'bladder wall follower'--a line follower with rules based on the characteristics of ultrasound imaging and the anatomy involved--is applied to the processed images to estimate the bladder wall location by following the portions of the bladder wall which are highlighted and filling in the missing segments. The results achieved using this scheme are presented.

  1. Arabidopsis Regenerating Protoplast: A Powerful Model System for Combining the Proteomics of Cell Wall Proteins and the Visualization of Cell Wall Dynamics

    Science.gov (United States)

    Yokoyama, Ryusuke; Kuki, Hiroaki; Kuroha, Takeshi; Nishitani, Kazuhiko

    2016-01-01

    The development of a range of sub-proteomic approaches to the plant cell wall has identified many of the cell wall proteins. However, it remains difficult to elucidate the precise biological role of each protein and the cell wall dynamics driven by their actions. The plant protoplast provides an excellent means not only for characterizing cell wall proteins, but also for visualizing the dynamics of cell wall regeneration, during which cell wall proteins are secreted. It therefore offers a unique opportunity to investigate the de novo construction process of the cell wall. This review deals with sub-proteomic approaches to the plant cell wall through the use of protoplasts, a methodology that will provide the basis for further exploration of cell wall proteins and cell wall dynamics. PMID:28248244

  2. Active sources in the cutoff of centrifugal fans to reduce the blade tones at higher-order duct mode frequencies

    Science.gov (United States)

    Neise, W.; Koopmann, G. H.

    1991-01-01

    A previously developed (e.g., Neise and Koopmann, 1984; Koopmann et al., 1988) active noise control technique in which the unwanted acoustic signals from centrifugal fans are suppressed by placing two externally driven sources near the cutoff of the casing was applied to the frequency region where not only plane sound waves are propagational in the fan ducts but also higher-order acoustic modes. Using a specially designed fan noise testing facility, the performance of two fans (280-mm impeller diam and 508 mm diam) was monitored with static pressure taps mounted peripherally around the inlet nozzle. Experimental results show that the aerodynamically generated source pressure field around the cutoff is too complex to be successfully counterimaged by only two active sources introduced in this region. It is suggested that, for an efficient application of this noise control technique in the higher-order mode frequency regime, it is neccessary to use an active source involving larger number of individually driven loudspeakers.

  3. Human variation and body mass index: a review of the universality of BMI cut-offs, gender and urban-rural differences, and secular changes.

    Science.gov (United States)

    Mascie-Taylor, C G Nicholas; Goto, Rie

    2007-03-01

    Use of BMI as a surrogate for body fat percentage is debatable and universal BMI cut-off points do not seem appropriate; lower cut-off points than currently recommended by WHO should be used in some populations, especially in Asia. The adult WHO BMI database indicates that, on average, women are more obese than men, while men are more likely to be pre-obese than women. Urban rates of overweight and obesity are generally higher than rural rates in both sexes. The trend in pre-obesity and obesity over time is generally upward, with very marked increases in the USA and UK in both sexes over the last 10 years.

  4. Removal of methadone by extended dialysis using a high cut-off dialyzer: implications for the treatment of overdose and for pain management in patients undergoing light chain removal.

    Science.gov (United States)

    Arelin, Viktor; Schmidt, Julius J; Kayser, Nathalie; Kühn-Velten, W Nikolaus; Suhling, Hendrik; Eden, Gabriele; Kielstein, Jan T

    2016-06-01

    The synthetic opioid methadone hydrochloride has a low molecular weight of 346 D, a high volume of distribution (4 - 7 L/kg), and is lipophilic. It is used as an analgesic and for the maintenance treatment of opiate dependence. In drug addicts, methadone is frequently involved in mixed intoxications that can lead to death. Here we present the case of a drug addict in whom a high cut-off dialysis membrane together with extended dialysis was used in the setting of suspected overdose and acute kidney injury. Although the observed dialyzer plasma clearance (31.5 mL/min) and reduction ratio (38%) were higher than previously reported for standard hemodialysis, the total amount of methadone in the spent dialysate after 1 extended dialysis session was quite low. Hence, even extended dialysis with a high cut-off membrane does not seem to offer a clinically relevant benefit in the setting of overdose for enhanced methadone removal. On the other hand, in patients undergoing high cut-off dialysis for the removal of light chains, methadone could still be used as an analgesic without an additional dose after high cut-off hemodialysis.

  5. Low-rise shear wall failure modes

    International Nuclear Information System (INIS)

    Farrar, C.R.; Hashimoto, P.S.; Reed, J.W.

    1991-01-01

    A summary of the data that are available concerning the structural response of low-rise shear walls is presented. This data will be used to address two failure modes associated with the shear wall structures. First, data concerning the seismic capacity of the shear walls with emphasis on excessive deformations that can cause equipment failure are examined. Second, data concerning the dynamic properties of shear walls (stiffness and damping) that are necessary to compute the seismic inputs to attached equipment are summarized. This case addresses the failure of equipment when the structure remains functional. 23 refs

  6. Sunspot Light Walls Suppressed by Nearby Brightenings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuhong; Zhang, Jun; Hou, Yijun; Li, Xiaohong [CAS Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Erdélyi, Robertus [Solar Physics and Space Plasma Research Centre, School of Mathematics and Statistics, University of Sheffield, Hicks Building, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Yan, Limei, E-mail: shuhongyang@nao.cas.cn [Key Laboratory of Earth and Planetary Physics, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029 (China)

    2017-07-01

    Light walls, as ensembles of oscillating bright structures rooted in sunspot light bridges, have not been well studied, although they are important for understanding sunspot properties. Using the Interface Region Imaging Spectrograph and Solar Dynamics Observatory observations, here we study the evolution of two oscillating light walls each within its own active region (AR). The emission of each light wall decays greatly after the appearance of adjacent brightenings. For the first light wall, rooted within AR 12565, the average height, amplitude, and oscillation period significantly decrease from 3.5 Mm, 1.7 Mm, and 8.5 minutes to 1.6 Mm, 0.4 Mm, and 3.0 minutes, respectively. For the second light wall, rooted within AR 12597, the mean height, amplitude, and oscillation period of the light wall decrease from 2.1 Mm, 0.5 Mm, and 3.0 minutes to 1.5 Mm, 0.2 Mm, and 2.1 minutes, respectively. Particularly, a part of the second light wall even becomes invisible after the influence of a nearby brightening. These results reveal that the light walls are suppressed by nearby brightenings. Considering the complex magnetic topology in light bridges, we conjecture that the fading of light walls may be caused by a drop in the magnetic pressure, where the flux is canceled by magnetic reconnection at the site of the nearby brightening. Another hypothesis is that the wall fading is due to the suppression of driver source ( p -mode oscillation), resulting from the nearby avalanche of downward particles along reconnected brightening loops.

  7. Effect of High-Cutoff Hemodialysis vs Conventional Hemodialysis on Hemodialysis Independence Among Patients With Myeloma Cast Nephropathy: A Randomized Clinical Trial.

    Science.gov (United States)

    Bridoux, Frank; Carron, Pierre-Louis; Pegourie, Brigitte; Alamartine, Eric; Augeul-Meunier, Karine; Karras, Alexandre; Joly, Bertrand; Peraldi, Marie-Noëlle; Arnulf, Bertrand; Vigneau, Cécile; Lamy, Thierry; Wynckel, Alain; Kolb, Brigitte; Royer, Bruno; Rabot, Nolwenn; Benboubker, Lotfi; Combe, Christian; Jaccard, Arnaud; Moulin, Bruno; Knebelmann, Bertrand; Chevret, Sylvie; Fermand, Jean-Paul

    2017-12-05

    Cast nephropathy is the main cause of acute kidney injury in multiple myeloma and persistent reduction in kidney function strongly affects prognosis. Strategies to rapidly remove nephrotoxic serum-free light chains combined with novel antimyeloma agents have not been evaluated prospectively. To compare the hemodialysis independence rate among patients newly diagnosed with myeloma cast nephropathy treated with hemodialysis using a high-cutoff dialyzer (with very large membrane pores and high permeability to immunoglobulin light chains) or a conventional high-flux dialyzer (with small pores and lower permeability). Randomized clinical trial involving 98 patients with biopsy-proven myeloma cast nephropathy requiring hemodialysis treated at 48 French centers between July 2011 and June 2016; the final date of follow-up was June 29, 2016. Intensive hemodialysis (eight 5-hour sessions over 10 days) with either a high-cutoff dialyzer (46 patients) or a conventional high-flux dialyzer (48 patients). All patients received the same chemotherapy regimen of bortezomib and dexamethasone. Primary end point was hemodialysis independence at 3 months; secondary end points: hemodialysis independence rates at 6 and 12 months, hemodialysis- and chemotherapy-related adverse events, and death. Among 98 randomized patients, 94 (96%) (median age, 68.8 years [interquartile range, 61.2-75.3 years]; 45% women) were included in the modified intent-to-treat analysis. The hemodialysis independence rate at 3 months was 41.3% (n = 19) in the high-cutoff hemodialysis group vs 33.3% (n = 16) in the conventional hemodialysis group (between-group difference, 8.0% [95% CI, -12.0% to 27.9%], P = .42); at 6 months, the rate was 56.5% (n = 26) vs 35.4% (n = 17), respectively (between-group difference, 21.1% [95% CI, 0.9% to 41.3%], P = .04); and at 12 months, the rate was 60.9% (n = 28) vs 37.5% (n = 18) (between-group difference, 23.4% [95% CI, 3.2% to 43.5%], P = .02

  8. Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Shum, Judy; DiMartino, Elena S.; Goldhammer, Adam; Goldman, Daniel H.; Acker, Leah C.; Patel, Gopal; Ng, Julie H.; Martufi, Giampaolo; Finol, Ender A.

    2010-01-01

    Purpose: Quantitative measurements of wall thickness in human abdominal aortic aneurysms (AAAs) may lead to more accurate methods for the evaluation of their biomechanical environment. Methods: The authors describe an algorithm for estimating wall thickness in AAAs based on intensity histograms and neural networks involving segmentation of contrast enhanced abdominal computed tomography images. The algorithm was applied to ten ruptured and ten unruptured AAA image data sets. Two vascular surgeons manually segmented the lumen, inner wall, and outer wall of each data set and a reference standard was defined as the average of their segmentations. Reproducibility was determined by comparing the reference standard to lumen contours generated automatically by the algorithm and a commercially available software package. Repeatability was assessed by comparing the lumen, outer wall, and inner wall contours, as well as wall thickness, made by the two surgeons using the algorithm. Results: There was high correspondence between automatic and manual measurements for the lumen area (r=0.978 and r=0.996 for ruptured and unruptured aneurysms, respectively) and between vascular surgeons (r=0.987 and r=0.992 for ruptured and unruptured aneurysms, respectively). The authors' automatic algorithm showed better results when compared to the reference with an average lumen error of 3.69%, which is less than half the error between the commercially available application Simpleware and the reference (7.53%). Wall thickness measurements also showed good agreement between vascular surgeons with average coefficients of variation of 10.59% (ruptured aneurysms) and 13.02% (unruptured aneurysms). Ruptured aneurysms exhibit significantly thicker walls (1.78±0.39 mm) than unruptured ones (1.48±0.22 mm), p=0.044. Conclusions: While further refinement is needed to fully automate the outer wall segmentation algorithm, these preliminary results demonstrate the method's adequate reproducibility and

  9. Double wall steam generator tubing

    International Nuclear Information System (INIS)

    Padden, T.R.; Uber, C.F.

    1983-01-01

    Double-walled steam generator tubing for the steam generators of a liquid metal cooled fast breeder reactor prevents sliding between the surfaces due to a mechanical interlock. Forces resulting from differential thermal expansion between the outer tube and the inner tube are insufficient in magnitude to cause shearing of base metal. The interlock is formed by jointly drawing the tubing, with the inside wall of the outer tube being already formed with grooves. The drawing causes the outer wall of the inner tube to form corrugations locking with the grooves. (author)

  10. Connection of thin-walled casings

    Energy Technology Data Exchange (ETDEWEB)

    Druyan, V.M.; Grinev, A.F.; Gruzdev, V.D.; Perchanik, V.V.; Syplenko, V.T.

    1981-08-28

    A connection is suggested for castings which contains a nipple and coupling part with conical triangular threading. in order to improve the strength of the connection of thin-walled casings with ratio D/S>22, where D is the outer diameter of the casing, S is the thickness of the wall of the casing, the end of the pipe on the length from the end to the main plane of the thread is conical with constant thickness of the wall and conicity eqal to the conicity of the thread.

  11. Making Your Music Word Wall Work

    Science.gov (United States)

    Leonhardt, Angela

    2011-01-01

    This article looks at what a word wall is and its use in the music classroom. The author outlines steps for creation of a word wall within the music classroom as well as the importance of such a resource. The author encourages the creation and consistent use of the word wall as leading to the development of stronger musicians and also independent,…

  12. HVI Ballistic Performance Characterization of Non-Parallel Walls

    Science.gov (United States)

    Bohl, William; Miller, Joshua; Christiansen, Eric

    2012-01-01

    The Double-Wall, "Whipple" Shield [1] has been the subject of many hypervelocity impact studies and has proven to be an effective shield system for Micro-Meteoroid and Orbital Debris (MMOD) impacts for spacecraft. The US modules of the International Space Station (ISS), with their "bumper shields" offset from their pressure holding rear walls provide good examples of effective on-orbit use of the double wall shield. The concentric cylinder shield configuration with its large radius of curvature relative to separation distance is easily and effectively represented for testing and analysis as a system of two parallel plates. The parallel plate double wall configuration has been heavily tested and characterized for shield performance for normal and oblique impacts for the ISS and other programs. The double wall shield and principally similar Stuffed Whipple Shield are very common shield types for MMOD protection. However, in some locations with many spacecraft designs, the rear wall cannot be modeled as being parallel or concentric with the outer bumper wall. As represented in Figure 1, there is an included angle between the two walls. And, with a cylindrical outer wall, the effective included angle constantly changes. This complicates assessment of critical spacecraft components located within outer spacecraft walls when using software tools such as NASA's BumperII. In addition, the validity of the risk assessment comes into question when using the standard double wall shield equations, especially since verification testing of every set of double wall included angles is impossible.

  13. Wall shear stress measurement of near-wall flow over inclined and curved boundaries by stereo interfacial particle image velocimetry

    International Nuclear Information System (INIS)

    Nguyen, Thien Duy; Wells, John Craig; Nguyen, Chuong Vinh

    2010-01-01

    In investigations of laminar or turbulent flows, wall shear is often important. Nevertheless, conventional particle image velocimetry (PIV) is difficult in near-wall regions. A near-wall measurement technique, named interfacial PIV (IPIV) [Nguyen, C., Nguyen, T., Wells, J., Nakayama, A., 2008. Proposals for PIV of near-wall flow over curved boundaries. In: Proceedings of 14th International Symposium on Applications of Laser Technique to Fluid Mechanics], handles curved boundaries by means of conformal transformation, directly measures the wall gradient, and yields the near-wall tangential velocity profile at one-pixel resolution. In this paper, we show the feasibility of extending IPIV to measure wall gradients by stereo reconstruction. First, we perform a test on synthetic images generated from a direct numerical simulation (DNS) snapshot of turbulent flow over sinusoidal bed. Comparative assessment of wall gradients derived by IPIV, stereo-IPIV and particle image distortion (PID) [Huang, H.T., Fiedler, H.E., Wang, J.J., 1993. Limitation and improvement of PIV. Experiments in Fluids 15(4), 263-273] is evaluated with DNS data. Also, the sensitivity of IPIV and stereo-IPIV results to the uncertainty of identified wall position is examined. As a practical application of IPIV and stereo-IPIV to experimental images, results from turbulent open channel flow over a backward-facing step are discussed in detail.

  14. Latitudinal variation rate of geomagnetic cutoff rigidity in the active Chilean convergent margin

    Science.gov (United States)

    Cordaro, Enrique G.; Venegas, Patricio; Laroze, David

    2018-03-01

    We present a different view of secular variation of the Earth's magnetic field, through the variations in the threshold rigidity known as the variation rate of geomagnetic cutoff rigidity (VRc). As the geomagnetic cutoff rigidity (Rc) lets us differentiate between charged particle trajectories arriving at the Earth and the Earth's magnetic field, we used the VRc to look for internal variations in the latter, close to the 70° south meridian. Due to the fact that the empirical data of total magnetic field BF and vertical magnetic field Bz obtained at Putre (OP) and Los Cerrillos (OLC) stations are consistent with the displacement of the South Atlantic magnetic anomaly (SAMA), we detected that the VRc does not fully correlate to SAMA in central Chile. Besides, the lower section of VRc seems to correlate perfectly with important geological features, like the flat slab in the active Chilean convergent margin. Based on this, we next focused our attention on the empirical variations of the vertical component of the magnetic field Bz, recorded in OP prior to the Maule earthquake in 2010, which occurred in the middle of the Chilean flat slab. We found a jump in Bz values and main frequencies from 3.510 to 5.860 µHz, in the second derivative of Bz, which corresponds to similar magnetic behavior found by other research groups, but at lower frequency ranges. Then, we extended this analysis to other relevant subduction seismic events, like Sumatra in 2004 and Tohoku in 2011, using data from the Guam station. Similar records and the main frequencies before each event were found. Thus, these results seem to show that magnetic anomalies recorded on different timescales, as VRc (decades) and Bz (days), may correlate with some geological events, as the lithosphere-atmosphere-ionosphere coupling (LAIC).

  15. ARFI cut-off values and significance of standard deviation for liver fibrosis staging in patients with chronic liver disease.

    Science.gov (United States)

    Goertz, Ruediger S; Sturm, Joerg; Pfeifer, Lukas; Wildner, Dane; Wachter, David L; Neurath, Markus F; Strobel, Deike

    2013-01-01

    Acoustic radiation force impulse (ARFI) elastometry quantifies hepatic stiffness, and thus degree of fibrosis, non-invasively. Our aim was to analyse the diagnostic accuracy of ARFI cut-off values, and the significance of a defined limit of standard deviation (SD) as a potential quality parameter for liver fibrosis staging in patients with chronic liver diseases (CLD). 153 patients with CLD (various aetiologies) undergoing liver biopsy, and an additional 25 patients with known liver cirrhosis, were investigated. ARFI measurements were performed in the right hepatic lobe, and correlated with the histopathological Ludwig fibrosis score (inclusion criteria: at least 6 portal tracts). The diagnostic accuracy of cut-off values was analysed with respect to an SD limit of 30% of the mean ARFI value. The mean ARFI elastometry showed 1.95 ± 0.87 m/s (range 0.79-4.40) in 178 patients (80 female, 98 male, mean age: 52 years). The cut-offs were 1.25 m/s for F ≥ 2, 1.72 m/s for F ≥ 3 and 1.75 m/s for F = 4, and the corresponding AUROC 80.7%, 86.2% and 88.7%, respectively. Exclusion of 31 patients (17.4%) with an SD higher than 30% of the mean ARFI improved the diagnostic accuracy: The AUROC for F ≥ 2, F ≥ 3 and F = 4 were 86.1%, 91.2% and 91.5%, respectively. The diagnostic accuracy of ARFI can be improved by applying a maximum SD of 30% of the mean ARFI as a quality parameter--which however leads to an exclusion of a relevant number of patients. ARFI results with a high SD should be interpreted with caution.

  16. Dental fear and caries in 6-12 year old children in Greece. Determination of dental fear cut-off points.

    Science.gov (United States)

    Boka, V; Arapostathis, K; Karagiannis, V; Kotsanos, N; van Loveren, C; Veerkamp, J

    2017-03-01

    To present: the normative data on dental fear and caries status; the dental fear cut-off points of young children in the city of Thessaloniki, Greece. Study Design: This is a cross-sectional study with two independent study groups. A first representative sample consisted of 1484 children from 15 primary public schools of Thessaloniki. A second sample consisted of 195 randomly selected age-matched children, all patients of the Postgraduate Paediatric Dental Clinic of Aristotle University of Thessaloniki. First sample: In order to select data on dental fear and caries, dental examination took place in the classroom with disposable mirrors and a penlight. All the children completed the Dental Subscale of the Children's Fear Survey Schedule (CFSS-DS). Second sample: In order to define the cut-off points of the CFSS-DS, dental treatment of the 195 children was performed at the University Clinic. Children⁁s dental fear was assessed using the CFSS-DS and their behaviour during dental treatment was observed by one calibrated examiner using the Venham scale. Statistical analysis of the data was performed with IBM SPSS Statistics 20 at a statistical significance level of fear. Mean differences between boys and girls were not significant. Caries was not correlated with dental fear. Second sample: CFSS-DSfear', scores 33-37 as 'borderline' and scores > 37 as 'dental fear'. In the first sample, 84.6% of the children did not suffer from dental fear (CFSS-DSfear was correlated to age and not to caries and gender. The dental fear cut-off point for the CFSS-DS was estimated at 37 for 6-12 year old children (33-37 borderlines).

  17. Don't Forget the Abdominal Wall: Imaging Spectrum of Abdominal Wall Injuries after Nonpenetrating Trauma.

    Science.gov (United States)

    Matalon, Shanna A; Askari, Reza; Gates, Jonathan D; Patel, Ketan; Sodickson, Aaron D; Khurana, Bharti

    2017-01-01

    Abdominal wall injuries occur in nearly one of 10 patients coming to the emergency department after nonpenetrating trauma. Injuries range from minor, such as abdominal wall contusion, to severe, such as abdominal wall rupture with evisceration of abdominal contents. Examples of specific injuries that can be detected at cross-sectional imaging include abdominal muscle strain, tear, or hematoma, including rectus sheath hematoma (RSH); traumatic abdominal wall hernia (TAWH); and Morel-Lavallée lesion (MLL) (closed degloving injury). These injuries are often overlooked clinically because of (a) a lack of findings at physical examination or (b) distraction by more-severe associated injuries. However, these injuries are important to detect because they are highly associated with potentially grave visceral and vascular injuries, such as aortic injury, and because their detection can lead to the diagnosis of these more clinically important grave traumatic injuries. Failure to make a timely diagnosis can result in delayed complications, such as bowel hernia with potential for obstruction or strangulation, or misdiagnosis of an abdominal wall neoplasm. Groin injuries, such as athletic pubalgia, and inferior costochondral injuries should also be considered in patients with abdominal pain after nonpenetrating trauma, because these conditions may manifest with referred abdominal pain and are often included within the field of view at cross-sectional abdominal imaging. Radiologists must recognize and report acute abdominal wall injuries and their associated intra-abdominal pathologic conditions to allow appropriate and timely treatment. © RSNA, 2017.

  18. ENHANCEMENT OF A SUNSPOT LIGHT WALL WITH EXTERNAL DISTURBANCES

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuhong; Zhang, Jun [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Erdélyi, Robert, E-mail: shuhongyang@nao.cas.cn [Solar Physics and Space Plasma Research Centre, School of Mathematics and Statistics, University of Sheffield, Hicks Building, Hounsfield Road, Sheffield S3 7RH (United Kingdom)

    2016-12-20

    Based on the Interface Region Imaging Spectrograph observations, we study the response of a solar sunspot light wall to external disturbances. A flare occurrence near the light wall caused material to erupt from the lower solar atmosphere into the corona. Some material falls back to the solar surface and hits the light bridge (i.e., the base of the light wall), then sudden brightenings appear at the wall base followed by the rise of wall top, leading to an increase of the wall height. Once the brightness of the wall base fades, the height of the light wall begins to decrease. Five hours later, another nearby flare takes place, and a bright channel is formed that extends from the flare toward the light bridge. Although no obvious material flow along the bright channel is found, some ejected material is conjectured to reach the light bridge. Subsequently, the wall base brightens and the wall height begins to increase again. Once more, when the brightness of the wall base decays, the wall top fluctuates to lower heights. We suggest, based on the observed cases, that the interaction of falling material and ejected flare material with the light wall results in the brightenings of wall base and causes the height of the light wall to increase. Our results reveal that the light wall can be not only powered by the linkage of p -mode from below the photosphere, but may also be enhanced by external disturbances, such as falling material.

  19. Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry : A worldwide collaborative project

    NARCIS (Netherlands)

    McHugh, David M. S.; Cameron, Cynthia A.; Abdenur, Jose E.; Abdulrahman, Mahera; Adair, Ona; Al Nuaimi, Shahira Ahmed; Ahlman, Henrik; Allen, Jennifer J.; Antonozzi, Italo; Archer, Shaina; Au, Sylvia; Auray-Blais, Christiane; Baker, Mei; Bamforth, Fiona; Beckmann, Kinga; Pino, Gessi Bentz; Berberich, Stanton L.; Binard, Robert; Boemer, Francois; Bonham, Jim; Breen, Nancy N.; Bryant, Sandra C.; Caggana, Michele; Caldwell, S. Graham; Camilot, Marta; Campbell, Carlene; Carducci, Claudia; Cariappa, Rohit; Carlisle, Clover; Caruso, Ubaldo; Cassanello, Michela; Miren Castilla, Ane; Castineiras Ramos, Daisy E.; Chakraborty, Pranesh; Chandrasekar, Ram; Ramos, Alfredo Chardon; Cheillan, David; Chien, Yin-Hsiu; Childs, Thomas A.; Chrastina, Petr; Sica, Yuri Cleverthon; Cocho de Juan, Jose Angel; Elena Colandre, Maria; Cornejo Espinoza, Veronica; Corso, Gaetano; Currier, Robert; Cyr, Denis; Czuczy, Noemi; D'Apolito, Oceania; Davis, Tim; de Sain-Van der Velden, Monique G.; Delgado Pecellin, Carmen; Di Gangi, Iole Maria; Di Stefano, Cristina Maria; Dotsikas, Yannis; Downing, Melanie; Downs, Stephen M.; Dy, Bonifacio; Dymerski, Mark; Rueda, Inmaculada; Elvers, Bert; Eaton, Roger; Eckerd, Barbara M.; El Mougy, Fatma; Eroh, Sarah; Espada, Mercedes; Evans, Catherine; Fawbush, Sandy; Fijolek, Kristel F.; Fisher, Lawrence; Franzson, Leifur; Frazier, Dianne M.; Garcia, Luciana R. C.; Garcia-Valdecasas Bermejo, Maria Sierra; Gavrilov, Dimitar; Gerace, Rosemarie; Giordano, Giuseppe; Irazabal, Yolanda Gonzalez; Greed, Lawrence C.; Grier, Robert; Grycki, Elyse; Gu, Xuefan; Gulamali-Majid, Fizza; Hagar, Arthur F.; Han, Lianshu; Hannon, W. Harry; Haslip, Christa; Hassan, Fayza Abdelhamid; He, Miao; Hietala, Amy; Himstedt, Leslie; Hoffman, Gary L.; Hoffman, William; Hoggatt, Philis; Hopkins, Patrick V.; Hougaard, David M.; Hughes, Kerie; Hunt, Patricia R.; Hwu, Wuh-Liang; Hynes, June; Ibarra-Gonzalez, Isabel; Ingham, Cindy A.; Ivanova, Maria; Jacox, Ward B.; John, Catharine; Johnson, John P.; Jonsson, Jon J.; Karg, Eszter; Kasper, David; Klopper, Brenda; Katakouzinos, Dimitris; Khneisser, Issam; Knoll, Detlef; Kobayashi, Hirinori; Koneski, Ronald; Kozich, Viktor; Kouapei, Rasoul; Kohlmueller, Dirk; Kremensky, Ivo; la Marca, Giancarlo; Lavochkin, Marcia; Lee, Soo-Youn; Lehotay, Denis C.; Lemes, Aida; Lepage, Joyce; Lesko, Barbara; Lewis, Barry; Lim, Carol; Linard, Sharon; Lindner, Martin; Lloyd-Puryear, Michele A.; Lorey, Fred; Loukas, Yannis L.; Luedtke, Julie; Maffitt, Neil; Magee, J. Fergall; Manning, Adrienne; Manos, Shawn; Marie, Sandrine; Hadachi, Sonia Marchezi; Marquardt, Gregg; Martin, Stephen J.; Matern, Dietrich; Gibson, Stephanie K. Mayfield; Mayne, Philip; McCallister, Tonya D.; McCann, Mark; McClure, Julie; McGill, James J.; McKeever, Christine D.; McNeilly, Barbara; Morrissey, Mark A.; Moutsatsou, Paraskevi; Mulcahy, Eleanor A.; Nikoloudis, Dimitris; Norgaard-Pedersen, Bent; Oglesbee, Devin; Oltarzewski, Mariusz; Ombrone, Daniela; Ojodu, Jelili; Papakonstantinou, Vagelis; Reoyo, Sherly Pardo; Park, Hyung-Doo; Pasquali, Marzia; Pasquini, Elisabetta; Patel, Pallavi; Pass, Kenneth A.; Peterson, Colleen; Pettersen, Rolf D.; Pitt, James J.; Poh, Sherry; Pollak, Arnold; Porter, Cory; Poston, Philip A.; Price, Ricky W.; Queijo, Cecilia; Quesada, Jonessy; Randell, Edward; Ranieri, Enzo; Raymond, Kimiyo; Reddic, John E.; Reuben, Alejandra; Ricciardi, Charla; Rinaldo, Piero; Rivera, Jeff D.; Roberts, Alicia; Rocha, Hugo; Roche, Geraldine; Greenberg, Cheryl Rochman; Egea Mellado, Jose Maria; Jess Juan-Fita, Maria; Ruiz, Consuelo; Ruoppolo, Margherita; Rutledge, S. Lane; Ryu, Euijung; Saban, Christine; Sahai, Inderneel; Salazar Garcia-Blanco, Maria Isabel; Santiago-Borrero, Pedro; Schenone, Andrea; Schoos, Roland; Schweitzer, Barb; Scott, Patricia; Seashore, Margretta R.; Seeterlin, Mary A.; Sesser, David E.; Sevier, Darrin W.; Shone, Scott M.; Sinclair, Graham; Skrinska, Victor A.; Stanley, Eleanor L.; Strovel, Erin T.; Jones, April L. Studinski; Sunny, Sherlykutty; Takats, Zoltan; Tanyalcin, Tijen; Teofoli, Francesca; Thompson, J. Robert; Tomashitis, Kathy; Domingos, Mouseline Torquado; Torres, Jasmin; Torres, Rosario; Tortorelli, Silvia; Turi, Sandor; Turner, Kimberley; Tzanakos, Nick; Valiente, Alf G.; Vallance, Hillary; Vela-Amieva, Marcela; Vilarinho, Laura; von Doebeln, Ulrika; Vincent, Marie-Francoise; Vorster, B. Chris; Watson, Michael S.; Webster, Dianne; Weiss, Sheila; Wilcken, Bridget; Wiley, Veronica; Williams, Sharon K.; Willis, Sharon A.; Woontner, Michael; Wright, Katherine; Yahyaoui, Raquel; Yamaguchi, Seiji; Yssel, Melissa; Zakowicz, Wendy M.

    Purpose: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. Methods: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25-30 million normal newborns and 10,742

  20. Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 2: 2x4 Walls

    Energy Technology Data Exchange (ETDEWEB)

    Kochkin, V. [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, J. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2017-06-01

    Part 2 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides straightforward and cost-effective strategies to construct durable, energy-efficient walls. It addresses walls constructed with 2x4 wood frame studs, wood structural panel (WSP) sheathing as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 inches thick over the WSP, and a cladding system installed over the foam sheathing in low-rise residential buildings up to three stories high. Walls with 2x6 framing are addressed in Part 1 of the Guide.

  1. Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 2: 2x4 Walls

    Energy Technology Data Exchange (ETDEWEB)

    Kochkin, V. [Home Innovation Research Labs, Upper Marlboro, MD (United States); Wiehagen, J. [Home Innovation Research Labs, Upper Marlboro, MD (United States)

    2017-08-31

    Part 2 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides straightforward and cost-effective strategies to construct durable, energy-efficient walls. It addresses walls constructed with 2x4 wood frame studs, wood structural panel (WSP) sheathing as wall bracing and added backing for foam sheathing, a layer of rigid foam sheathing insulation up to 1.5 inches thick over the WSP, and a cladding system installed over the foam sheathing in low-rise residential buildings up to three stories high. Walls with 2x6 framing are addressed in Part 1 of the Guide.

  2. Seismic Performance of Precast Polystyrene RC Walls

    Directory of Open Access Journals (Sweden)

    Wibowo Ari

    2017-01-01

    Full Text Available Precast concrete structure such as precast wall is a concept that is growing rapidly these days. However, the earthquake resistance is believed to be one of its drawbacks. Additionally, the large weight of solid elements also increase the building weight significantly which consequently increase the earthquake base shear force as well. Therefore, investigation on the seismic performance of precast concrete wall has been carried out. Three RC wall specimens using wire mesh reinforcement and EPS (Extended Polystyrene System panel have been tested. This wall was designed as a structural wall that was capable in sustaining lateral loads (in-plane yet were lightweight to reduce the total weight of the building. Parameter observed was the ratio of height to width (aspect ratio of wall of 1.0, 1.5 and 2.0 respectively with the aim to study the behaviour of brittle to ductile transition of the wall. Incremental static load tests were conducted until reaching peak load and then followed by displacement control until failure. Several data were measured at every stage of loading comprising lateral load-displacement behaviour, ultimate strength and collapse mechanism. The outcomes showed that precast concrete walls with a steel wire and EPS panel filler provided considerably good resistance against lateral load.

  3. Kinetic wall from Israel

    Energy Technology Data Exchange (ETDEWEB)

    Godolphin, D.

    1985-05-01

    An unusual solar mass wall is described. At the turn of a handle it can change from a solar energy collector to a heat-blocker. An appropriate name for it might be the rotating prism wall. An example of the moving wall is at work in an adobe test home in Sede Boqer. Behind a large south-facing window stand four large adobe columns that are triangular in plan. One face of each of them is painted black to absorb sunlight, a second is covered with panels of polystyrene insulation, and a third is painted to match the room decor. These columns can rotate. On winter nights, the insulated side faces the glass, keeping heat losses down. The same scheme works in summer to keep heat out of the house. Small windows provide ventilation.

  4. Measurements of wall shear stress in a planar turbulent Couette flow with porous walls

    Science.gov (United States)

    Beuther, Paul

    2013-11-01

    Measurements of drag on a moving web in a multi-span festoon show a stronger than expected dependency on the porosity of the web. The experiments suggest a wall shear stress 3-4 times larger than non-porous webs or historical Couette flow data for solid walls. Previous DNS studies by Jimenez et al. (JFM Vol 442) of boundary layers with passive porous surfaces predict a much smaller increase in wall shear stress for a porous wall of only 40%. Other DNS studies by Quadrio et al. (JFM Vol 576) of porous walls with periodic transpiration do show a large increase in drag under certain periodic conditions of modest amplitude. Although those results are aligned in magnitude with this study, the exact reason for the observed high drag for porous webs in this present study is not understood because there was no external disturbance applied to the web. It can be hypothesized that natural flutter of the web results in a similar mechanism shown in the periodic DNS study, but when the natural flutter was reduced by increasing web tension, there was only a small decrease of the drag. A key difference in this study is that because of the multiple parallel spans in a festoon, any transpiration in one layer must act in the opposite manner on the adjacent span.

  5. High Performance Walls in Hot-Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [National Renewable Energy Lab. (NREL), Golden, CO (United States); Springer, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dakin, Bill [National Renewable Energy Lab. (NREL), Golden, CO (United States); German, Alea [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-01-01

    High performance walls represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. The primary goal in improving wall thermal performance revolves around increasing the wall framing from 2x4 to 2x6, adding more cavity and exterior rigid insulation, achieving insulation installation criteria meeting ENERGY STAR's thermal bypass checklist, and reducing the amount of wood penetrating the wall cavity.

  6. Post wall fixation by lag screw only in associated both column fractures with posterior wall involvement.

    Science.gov (United States)

    Wang, Hu; Utku, Kandemir; Zhuang, Yan; Zhang, Kun; Fu, Ya-Hui; Wei, Xing; Wang, Peng-Fei; Cong, Yu-Xuan; Lei, Jin-Lai; Zhang, Bin-Fei

    2017-07-01

    To evaluate the quality of reduction, clinical outcomes and complications of associated both column acetabular fractures with posterior wall involvement that are treated through single ilioinguinal approach and fixation of posterior wall by lag screws only. We conducted a retrospective review involving ninety-nine consecutive patients with associated both column fractures of acetabulum treated through single ilioinguinal approach. Patients were divided into two groups. The first group consisted of 35 patients presented with both column fractures with posterior wall involvement that fixation performed with lag screws. This group was compared to a second group of 64 patients with both column fractures without posterior wall involvement. The quality of reduction was assessed using criteria described by Matta. The size of posterior wall fragment was measured. Functional outcome was evaluated using Modified Postel Merle D'Aubigne score. Radiographs at the latest follow up were analyzed for arthritis (Kellgren-Lawrence classification), and femoral head avascular necrosis (Ficat/Arlet classification). The study showed no significant differences in all preoperative variables (P>0.05). While intraoperative blood loss and operative time in group 1 were increased compared to group 2, the difference was not statistically significant (P>0.05). The height, relative depth and peripheral length of posterior wall respectively were 27.8±2.5mm (range: 24-35mm), 71.5±5.4% (range: 65-88%), 23.0±2.3mm (range: 17-28mm). The mean posterior wall fracture displacement is 5.0±3.2mm (range: 0-11mm). There was no difference regarding the quality of reduction between the two groups (P>0.05). The excellent to good clinical outcome was around 71.4% in the group 1 versus 73.4% in the group 2 at the final follow-up, this difference was not statistically significant (P>0.05). There was no difference in rate of complications between the two groups (P>0.05). Lag screws fixation of posterior wall

  7. Dynamics of plane-symmetric thin walls in general relativity

    International Nuclear Information System (INIS)

    Wang, A.

    1992-01-01

    Plane walls (including plane domain walls) without reflection symmetry are studied in the framework of Einstein's general relativity. Using the distribution theory, all the Einstein field equations and Bianchi identities are split into two groups: one holding in the regions outside of the wall and the other holding at the wall. The Einstein field equations at the wall are found to take a very simple form, and given explicitly in terms of the discontinuities of the metric coefficients and their derivatives. The Bianchi identities at the wall are also given explicitly. Using the latter, the interaction of a plane wall with gravitational waves and some specific matter fields is studied. In particular, it is found that, when a gravitational plane wave passes through a wall, if the wall has no reflection symmetry, the phenomena, such as reflection, stimulation, or absorption, in general, occur. It is also found that, unlike for gravitational waves, a massless scalar wave or an electromagnetic wave continuously passes through a wall without any reflection. The repulsion and attraction of a plane wall are also studied. It is found that the acceleration of an observer who is at rest relative to the wall usually consists of three parts: one is due to the force produced by the wall, the second is due to the force produced by the space-time curvature, which is zero if the wall has reflection symmetry, and the last is due to the accelerated motion of the wall. As a result, a repulsive (attractive) plane wall may not be repulsive (attractive) at all. Finally, the collision and interaction among the walls are studied

  8. The Hb E (HBB: c.79G>A), Mean Corpuscular Volume, Mean Corpuscular Hemoglobin Cutoff Points in Double Heterozygous Hb E/- -SEA α-Thalassemia-1 Carriers are Dependent on Hemoglobin Levels.

    Science.gov (United States)

    Leckngam, Prapapun; Limweeraprajak, Ektong; Kiewkarnkha, Tiemjan; Tatu, Thanusak

    2017-01-01

    Identifying double heterozygosities in Hb E (HBB: c.79 G>A)/- - SEA (Southeast Asian) (α-thalassemia-1) (α-thal-1) in patients first diagnosed as carrying Hb E is important in thalassemia control. Low Hb E, mean corpuscular volume (MCV) and mean corpuscular hemoglobin (Hb) (MCH) levels have been observed in this double heterozygosity. However, the cutoff points of these parameters have never been systematically established. Here, we analyzed Hb E and red blood cell (RBC) parameters in 372 Hb E patients grouped by Hb levels, by the status of - - SEA and -α 3.7 (α-thal-2; rightward) deletions, to establish the cutoff points. Then, the established cutoff points were evaluated in 184 Hb E patients. It was found that the cutoff points of Hb E, MCV, MCH were significantly dependent on the Hb levels. In the group having Hb levels Hb E, MCV and MCH were 21.2%, 64.9 fL and 21.0 pg, respectively, and were 25.6%, 72.8 fL and 23.9 pg, respectively, in the group having Hb levels 10.0-11.9 g/dL. Finally, in the group having Hb levels ≥12.0 g/dL, the cutoff points of Hb E, MCV and MCH were 27.1%, 76.7 fL and 25.3 pg, respectively. Thus, to screen for the double heterozygous Hb E/- - SEA anomaly in patients initially diagnosed as carrying Hb E, the Hb levels must be taken into account in choosing the suitable cutoff points of these three parameters.

  9. Optimal cut-off of homeostasis model assessment of insulin resistance (HOMA-IR) for the diagnosis of metabolic syndrome: third national surveillance of risk factors of non-communicable diseases in Iran (SuRFNCD-2007).

    Science.gov (United States)

    Esteghamati, Alireza; Ashraf, Haleh; Khalilzadeh, Omid; Zandieh, Ali; Nakhjavani, Manouchehr; Rashidi, Armin; Haghazali, Mehrdad; Asgari, Fereshteh

    2010-04-07

    We have recently determined the optimal cut-off of the homeostatic model assessment of insulin resistance for the diagnosis of insulin resistance (IR) and metabolic syndrome (MetS) in non-diabetic residents of Tehran, the capital of Iran. The aim of the present study is to establish the optimal cut-off at the national level in the Iranian population with and without diabetes. Data of the third National Surveillance of Risk Factors of Non-Communicable Diseases, available for 3,071 adult Iranian individuals aging 25-64 years were analyzed. MetS was defined according to the Adult Treatment Panel III (ATPIII) and International Diabetes Federation (IDF) criteria. HOMA-IR cut-offs from the 50th to the 95th percentile were calculated and sensitivity, specificity, and positive likelihood ratio for MetS diagnosis were determined. The receiver operating characteristic (ROC) curves of HOMA-IR for MetS diagnosis were depicted, and the optimal cut-offs were determined by two different methods: Youden index, and the shortest distance from the top left corner of the curve. The area under the curve (AUC) (95%CI) was 0.650 (0.631-0.670) for IDF-defined MetS and 0.683 (0.664-0.703) with the ATPIII definition. The optimal HOMA-IR cut-off for the diagnosis of IDF- and ATPIII-defined MetS in non-diabetic individuals was 1.775 (sensitivity: 57.3%, specificity: 65.3%, with ATPIII; sensitivity: 55.9%, specificity: 64.7%, with IDF). The optimal cut-offs in diabetic individuals were 3.875 (sensitivity: 49.7%, specificity: 69.6%) and 4.325 (sensitivity: 45.4%, specificity: 69.0%) for ATPIII- and IDF-defined MetS, respectively. We determined the optimal HOMA-IR cut-off points for the diagnosis of MetS in the Iranian population with and without diabetes.

  10. OSCILLATING LIGHT WALL ABOVE A SUNSPOT LIGHT BRIDGE

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuhong; Zhang, Jun; Jiang, Fayu [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Xiang, Yongyuan, E-mail: shuhongyang@nao.cas.cn [Fuxian Solar Observatory, Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China)

    2015-05-10

    With the high tempo-spatial Interface Region Imaging Spectrograph 1330 Å images, we find that many bright structures are rooted in the light bridge of NOAA 12192, forming a light wall. The light wall is brighter than the surrounding areas, and the wall top is much brighter than the wall body. The New Vacuum Solar Telescope Hα and the Solar Dynamics Observatory 171 and 131 Å images are also used to study the light-wall properties. In 1330, 171, and 131 Å, the top of the wall has a higher emission, while in the Hα line, the wall-top emission is very low. The wall body corresponds to bright areas in 1330 Å and dark areas in the other lines. The top of the light wall moves upward and downward successively, performing oscillations in height. The deprojected mean height, amplitude, oscillation velocity, and the dominant period are determined to be 3.6 Mm, 0.9 Mm, 15.4 km s{sup −1}, and 3.9 minutes, respectively. We interpret the oscillations of the light wall as the leakage of p-modes from below the photosphere. The constant brightness enhancement of the wall top implies the existence of some kind of atmospheric heating, e.g., via the persistent small-scale reconnection or the magneto-acoustic waves. In another series of 1330 Å images, we find that the wall top in the upward motion phase is significantly brighter than in the downward phase. This kind of oscillation may be powered by the energy released due to intermittent impulsive magnetic reconnection.

  11. Evaluation of cell wall preparations for proteomics: a new procedure for purifying cell walls from Arabidopsis hypocotyls

    Directory of Open Access Journals (Sweden)

    Canut Hervé

    2006-05-01

    Full Text Available Abstract Background The ultimate goal of proteomic analysis of a cell compartment should be the exhaustive identification of resident proteins; excluding proteins from other cell compartments. Reaching such a goal closely depends on the reliability of the isolation procedure for the cell compartment of interest. Plant cell walls possess specific difficulties: (i the lack of a surrounding membrane may result in the loss of cell wall proteins (CWP during the isolation procedure, (ii polysaccharide networks of cellulose, hemicelluloses and pectins form potential traps for contaminants such as intracellular proteins. Several reported procedures to isolate cell walls for proteomic analyses led to the isolation of a high proportion (more than 50% of predicted intracellular proteins. Since isolated cell walls should hold secreted proteins, one can imagine alternative procedures to prepare cell walls containing a lower proportion of contaminant proteins. Results The rationales of several published procedures to isolate cell walls for proteomics were analyzed, with regard to the bioinformatic-predicted subcellular localization of the identified proteins. Critical steps were revealed: (i homogenization in low ionic strength acid buffer to retain CWP, (ii purification through increasing density cushions, (iii extensive washes with a low ionic strength acid buffer to retain CWP while removing as many cytosolic proteins as possible, and (iv absence of detergents. A new procedure was developed to prepare cell walls from etiolated hypocotyls of Arabidopsis thaliana. After salt extraction, a high proportion of proteins predicted to be secreted was released (73%, belonging to the same functional classes as proteins identified using previously described protocols. Finally, removal of intracellular proteins was obtained using detergents, but their amount represented less than 3% in mass of the total protein extract, based on protein quantification. Conclusion The

  12. Control of Wall Mounting Robot

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Pedersen, Rasmus

    2017-01-01

    This paper presents a method for designing controllers for trajectory tracking with actuator constraints. In particular, we consider a joystick-controlled wall mounting robot called WallMo. In contrast to previous works, a model-free approach is taken to the control problem, where the path...

  13. Moisture Research - Optimizing Wall Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L.; Mantha, P.

    2013-05-01

    The Consortium for Advanced Residential Buildings (CARB) evaluated several different configurations of wall assemblies to determine the accuracy of moisture modeling and make recommendations to ensure durable, efficient assemblies. WUFI and THERM were used to model the hygrothermal and heat transfer characteristics of these walls.

  14. Modeling of shear wall buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, A K [North Carolina State Univ., Raleigh (USA). Dept. of Civil Engineering

    1984-05-01

    Many nuclear power plant buildings, for example, the auxiliary building, have reinforced concrete shear walls as the primary lateral load resisting system. Typically, these walls have low height to length ratio, often less than unity. Such walls exhibit marked shear lag phenomenon which would affect their bending stiffness and the overall stress distribution in the building. The deformation and the stress distribution in walls have been studied which is applicable to both the short and the tall buildings. The behavior of the wall is divided into two parts: the symmetric flange action and the antisymmetry web action. The latter has two parts: the web shear and the web bending. Appropriate stiffness equations have been derived for all the three actions. These actions can be synthesized to solve any nonlinear cross-section. Two specific problems, that of lateral and torsional loadings of a rectangular box, have been studied. It is found that in short buildings shear lag plays a very important role. Any beam type formulation which either ignores shear lag or includes it in an idealized form is likely to lead to erroneous results. On the other hand a rigidity type approach with some modifications to the standard procedures would yield nearly accurate answers.

  15. Timber frame walls

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place; Brandt, Erik

    2010-01-01

    A ventilated cavity is usually considered good practice for removing moisture behind the cladding of timber framed walls. Timber frame walls with no cavity are a logical alternative as they are slimmer and less expensive to produce and besides the risk of a two-sided fire behind the cladding....... It was found that the specific damages made to the vapour barrier as part of the test did not have any provable effect on the moisture content. In general elements with an intact vapour barrier did not show a critical moisture content at the wind barrier after four years of exposure....

  16. From Soft Walls to Infrared Branes

    CERN Document Server

    von Gersdorff, Gero

    2010-01-01

    Five dimensional warped spaces with soft walls are generalizations of the standard Randall-Sundrum compactifications, where instead of an infrared brane one has a curvature singularity (with vanishing warp factor) at finite proper distance in the bulk. We project the physics near the singularity onto a hypersurface located a small distance away from it in the bulk. This results in a completely equivalent description of the soft wall in terms of an effective infrared brane, hiding any singular point. We perform explicitly this calculation for two classes of soft wall backgrounds used in the literature. The procedure has several advantages. It separates in a clean way the physics of the soft wall from the physics of the five dimensional bulk, facilitating a more direct comparison with standard two-brane warped compactifications. Moreover, consistent soft walls show a sort of universal behavior near the singularity which is reflected in the effective brane Lagrangian. Thirdly, for many purposes, a good approxima...

  17. Experimental investigation on particle-wall interactions

    International Nuclear Information System (INIS)

    Zeisel, H.; Dorfner, V.

    1988-01-01

    There is still a lack in the knowledge about many physical processes in two-phase flows and therefore their mathematical description for the modelling of two-phase flows by computer simulations still needs some improvement. One required information is the physical procedure of the momentum transfer between the phases themselves, such as particle-particle or particle-fluid interactions, and between the phases and the flow boundaries, such as particle-wall or fluid-wall interactions. The interaction between the two phases can be either a 'long-range' interference or a direct contact between both. For the particle-fluid two-phase flow system the interaction can be devided in particle-fluid, particle-particle and particle-boundary interactions. In this investigation the attention is drawn to the special case of a particle-wall interaction and its 'long-range' interference effect between the wall and a small particle which approaches the wall in normal direction. (orig./GL)

  18. Moisture Management for High R-Value Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lepage, R.; Schumacher, C.; Lukachko, A.

    2013-11-01

    The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.

  19. Hygrothermal behavior for a clay brick wall

    Science.gov (United States)

    Allam, R.; Issaadi, N.; Belarbi, R.; El-Meligy, M.; Altahrany, A.

    2018-06-01

    In Egypt, the clay brick is the common building materials which are used. By studying clay brick walls behavior for the heat and moisture transfer, the efficient use of the clay brick can be reached. So, this research studies the hygrothermal transfer in this material by measuring the hygrothermal properties and performing experimental tests for a constructed clay brick wall. We present the model for the hygrothermal transfer in the clay brick which takes the temperature and the vapor pressure as driving potentials. In addition, this research compares the presented model with previous models. By constructing the clay brick wall between two climates chambers with different boundary conditions, we can validate the numerical model and analyze the hygrothermal transfer in the wall. The temperature and relative humidity profiles within the material are measured experimentally and determined numerically. The numerical and experimental results have a good convergence with 3.5% difference. The surface boundary conditions, the ground effect, the infiltration from the closed chambers and the material heterogeneity affects the results. Thermal transfer of the clay brick walls reaches the steady state very rapidly than the moisture transfer. That means the effect of using only the external brick wall in the building in hot climate without increase the thermal resistance for the wall, will add more energy losses in the clay brick walls buildings. Also, the behavior of the wall at the heat and mass transfer calls the three-dimensional analysis for the whole building to reach the real behavior.

  20. Hygrothermal behavior for a clay brick wall

    Science.gov (United States)

    Allam, R.; Issaadi, N.; Belarbi, R.; El-Meligy, M.; Altahrany, A.

    2018-01-01

    In Egypt, the clay brick is the common building materials which are used. By studying clay brick walls behavior for the heat and moisture transfer, the efficient use of the clay brick can be reached. So, this research studies the hygrothermal transfer in this material by measuring the hygrothermal properties and performing experimental tests for a constructed clay brick wall. We present the model for the hygrothermal transfer in the clay brick which takes the temperature and the vapor pressure as driving potentials. In addition, this research compares the presented model with previous models. By constructing the clay brick wall between two climates chambers with different boundary conditions, we can validate the numerical model and analyze the hygrothermal transfer in the wall. The temperature and relative humidity profiles within the material are measured experimentally and determined numerically. The numerical and experimental results have a good convergence with 3.5% difference. The surface boundary conditions, the ground effect, the infiltration from the closed chambers and the material heterogeneity affects the results. Thermal transfer of the clay brick walls reaches the steady state very rapidly than the moisture transfer. That means the effect of using only the external brick wall in the building in hot climate without increase the thermal resistance for the wall, will add more energy losses in the clay brick walls buildings. Also, the behavior of the wall at the heat and mass transfer calls the three-dimensional analysis for the whole building to reach the real behavior.