WorldWideScience

Sample records for ctix injection experiment

  1. Profiling compact toroid plasma density on CTIX with laser deflection

    Science.gov (United States)

    Brockington, Samuel Joseph Erwin

    A laser deflectometer measures line-integrated plasma density gradient using laser diodes and amplified point detectors. A laser passing through an optically thin plasma is refracted by an amount proportional to the line-integrated electron density gradient. I have designed, installed, and operated a deflection diagnostic for the Compact Toroid Injection Experiment (CTIX), a plasma rail gun which can create compact toroid (CT) plasmas of controllable density and velocity. The diagnostic design and motivation are discussed, as well as three experiments performed with deflectometry. Thus, my thesis consists of the design of the deflectometer diagnostic, a comparison of its accuracy to interferometer density measurements, and finally a survey of compact toroid density profiles in two dimensions conducted with an array of detectors.

  2. Laser-driven Beat-Wave Current Drive in Dense Plasmas with Demo on CTIX

    Science.gov (United States)

    Liu, Fei; Horton, Robert; Hwang, David; Zhu, Ben; Evans, Russell; Hong, Sean; Hsu, Scott

    2010-11-01

    The ability to remotely generate plasma current in dense plasmas hanging freely in vacuum in voluminous amount without obstruction to diagnostics will greatly enhance our ability to study the physics of high energy density plasmas in strong magnetic fields. Plasma current can be generated through nonlinear beat-wave process by launching two intense electromagnetic waves into unmagnetized plasma. Beat-wave acceleration of electrons has been demonstrated in a low-density plasma using microwaves [1]. The proposed PLX experimental facility presently under construction at Los Alamos offers the opportunity to test the method at a density level scalable to the study of HED plasmas. For PLX beat-wave experiments, CO2 lasers will be used as pump waves due to their high power and tunability. For a typical PLX density ne=10^17cm-3, two CO2 lasers can be separately tuned to 9P(28) and 10P(20) to match the 2.84THz plasma frequency. The beat-wave demo experiment will be conducted on CTIX. The laser arrangement is being converted to two independent single lasers. Frequency-tuning methods, optics focusing system and diagnostics system will be discussed. The laser measurements and results of synchronization of two lasers will be presented, and scaling to PLX experiments will be given. [1] Rogers, J. H. and Hwang, D. Q., PRL. v68 p3877 (1992).

  3. Dense Plasma Injection Experiment at MCX

    Science.gov (United States)

    Uzun-Kaymak, I.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Hassam, A.; Teodorescu, C.; Witherspoon, D.; Young, W.

    2009-09-01

    We present preliminary results of the High Density Plasma Injection Experiment at the Maryland Centrifugal Experiment (MCX). HyperV Technologies Corp. has designed, built, and installed a prototype coaxial gun to drive rotation in MCX. This gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. An array of diagnostics indicates the gun is capable of plasma jets with a mass of 160 μg at 70 km/s with an average plasma density above 1015 cm-3. Preliminary measurements are underway at MCX to understand the penetration of the plasma jet through the MCX magnetic field and the momentum transfer from the jet to the MCX plasma. Data will be presented for a wide range of MCX field parameters, and the prospects for future injection experiments will be evaluated.

  4. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  5. Flux-Level Transit Injection Experiments with NASA Pleiades Supercomputer

    Science.gov (United States)

    Li, Jie; Burke, Christopher J.; Catanzarite, Joseph; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    Flux-Level Transit Injection (FLTI) experiments are executed with NASA's Pleiades supercomputer for the Kepler Mission. The latest release (9.3, January 2016) of the Kepler Science Operations Center Pipeline is used in the FLTI experiments. Their purpose is to validate the Analytic Completeness Model (ACM), which can be computed for all Kepler target stars, thereby enabling exoplanet occurrence rate studies. Pleiades, a facility of NASA's Advanced Supercomputing Division, is one of the world's most powerful supercomputers and represents NASA's state-of-the-art technology. We discuss the details of implementing the FLTI experiments on the Pleiades supercomputer. For example, taking into account that ~16 injections are generated by one core of the Pleiades processors in an hour, the “shallow” FLTI experiment, in which ~2000 injections are required per target star, can be done for 16% of all Kepler target stars in about 200 hours. Stripping down the transit search to bare bones, i.e. only searching adjacent high/low periods at high/low pulse durations, makes the computationally intensive FLTI experiments affordable. The design of the FLTI experiments and the analysis of the resulting data are presented in “Validating an Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments” by Catanzarite et al. (#2494058).Kepler was selected as the 10th mission of the Discovery Program. Funding for the Kepler Mission has been provided by the NASA Science Mission Directorate.

  6. Laboratory Experiments on Enhanced Oil Recovery with Nitrogen Injection

    Directory of Open Access Journals (Sweden)

    S. Siregar

    2007-05-01

    Full Text Available Based on previous studies, nitrogen injection could recover oil up to 45-90% of initial reserves. Although this method has a very good ability to produce oil, sometimes the operation pressure is higher than leak off formation pressure. In this study, operation pressure used a low pressure to solve this problem under immiscible process. Objective of this study is to determine the effect of injection pressure and displacement rate on oil recovery performance of continuous one dimensional nitrogen gas injection with a slim tube apparatus. The effect of nitrogen gas-oil contact on the gas composition was investigated using Gas Chromatograph Mass Spectrometer apparatus. In the experiments, nitrogen gas was injected into an oil sample of 38.5 oAPI gravity at various rates: 20 cc/hr, 30 cc/hr and 36.66/hr under 1500 psi pressure, and then at 20 cc/hr undr 2500 psi pressure. The results showed that an increase in injection rate increased oil recovery factor. The recovery factor lies between 40-54% of original oil in place. Gas analysis before injection and at the injection outlet showed a change of composition. when oil was contacted by nitrogen, indicating that some molecular mass transfer had taken place.

  7. Geothermal injection treatment: process chemistry, field experiences, and design options

    Energy Technology Data Exchange (ETDEWEB)

    Kindle, C.H.; Mercer, B.W.; Elmore, R.P.; Blair, S.C.; Myers, D.A.

    1984-09-01

    The successful development of geothermal reservoirs to generate electric power will require the injection disposal of approximately 700,000 gal/h (2.6 x 10/sup 6/ 1/h) of heat-depleted brine for every 50,000 kW of generating capacity. To maintain injectability, the spent brine must be compatible with the receiving formation. The factors that influence this brine/formation compatibility and tests to quantify them are discussed in this report. Some form of treatment will be necessary prior to injection for most situations; the process chemistry involved to avoid and/or accelerate the formation of precipitate particles is also discussed. The treatment processes, either avoidance or controlled precipitation approaches, are described in terms of their principles and demonstrated applications in the geothermal field and, when such experience is limited, in other industrial use. Monitoring techniques for tracking particulate growth, the effect of process parameters on corrosion and well injectability are presented. Examples of brine injection, preinjection treatment, and recovery from injectivity loss are examined and related to the aspects listed above.

  8. Neutral Beam Injection Experiments in the HL-1M Tokamak

    Institute of Scientific and Technical Information of China (English)

    严龙文; 雷光玖; 钟光武; 江涛; 周艳; 姜韶风; 丁玄同; 周才品; 刘永

    2003-01-01

    Neutral beam injection (NBI) experiments have been carried out with two operation modes of a bucket ion source in the HL-1M tokamak. During the first mode, more than 30% rise in ion temperature above the Ohmic level is routinely achieved after NBI power about 0. 5 MW is injected. Ion temperature only increases 20-30% for the second operation mode, which is often limited by current termination. The heating effects of the NBI have been analysed experimentally and theoretically. The performance of the NBI system is well described.

  9. Multiple-applications of Accelerated Compact Toroid Injection for MFE

    Science.gov (United States)

    Hwang, David; Horton, Robert; Evans, Russell; Liu, Fei; Zhu, Ben; Hong, Sean; Buchenauer, Dean

    2010-11-01

    The CTIX experiment has explored the potential applications of launching a fast moving magnetized compact toroid for Magnetic Fusion experiments. These applications include central fueling of a MFE device such as tokamaks, stellarators, etc. At present, the UC Davis CTIX accelerator has achieved densities at mid to upper 10^15 per cc, at speeds reaching over 200 km/sec. In order to meet the parameters of even larger fusion devices, the technology of the accelerator needs to incorporate the latest plasma wall interaction findings. As a result of the next step in CT development, UC Davis will be collaborating with the Fusion Technology group at Sandia National Laboratory in Livermore California. We will be designing new plasmas facing electrodes that can reduce electrode impurities and increase electrode lifetime. In addition to producing high density CTs, we will include the updated conical compression results from our previous installed drift section compressor. In addition of the MFE applications, the ability to enhance the CT density, fields as well as speed can be useful to other fusion areas such as MIF, etc.

  10. Modeling of Carbon Migration During JET Injection Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Strachan, J. D.; Likonen, J.; Coad, P.; Rubel, M.; Widdowson, A.; Airila, M.; Andrew, P.; Brezinsek, S.; Corrigan, G.; Esser, H. G.; Jachmich, S.; Kallenbach, A.; Kirschner, A.; Kreter, A.; Matthews, G. F.; Philipps, V.; Pitts, R. A.; Spence, J.; Stamp, M.; Wiesen, S.

    2008-10-15

    JET has performed two dedicated carbon migration experiments on the final run day of separate campaigns (2001 and 2004) using {sup 13}CH{sub 4} methane injected into repeated discharges. The EDGE2D/NIMBUS code modelled the carbon migration in both experiments. This paper describes this modelling and identifies a number of important migration pathways: (1) deposition and erosion near the injection location, (2) migration through the main chamber SOL, (3) migration through the private flux region aided by E x B drifts, and (4) neutral migration originating near the strike points. In H-Mode, type I ELMs are calculated to influence the migration by enhancing erosion during the ELM peak and increasing the long-range migration immediately following the ELM. The erosion/re-deposition cycle along the outer target leads to a multistep migration of {sup 13}C towards the separatrix which is called 'walking'. This walking created carbon neutrals at the outer strike point and led to {sup 13}C deposition in the private flux region. Although several migration pathways have been identified, quantitative analyses are hindered by experimental uncertainty in divertor leakage, and the lack of measurements at locations such as gaps and shadowed regions.

  11. IIST small break LOCA experiments with passive core cooling injection

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.-J. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China)]. E-mail cjchang@iner.gov.tw; Lee, C.-H. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China); Hong, W.-T. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China); Wang, Lance L.C. [Lungmen Project Quality Supervisory and Directory Committee, Taiwan Power Company, 62, Yeh-Hai St., Kung-Liao, Taipei County, Taiwan 238 (China)

    2006-01-15

    The purpose of this study is to evaluate the performance of a passive core cooling system (PCCS) with passive injection during the cold-leg small break loss-of-coolant accidents (SBLOCAs) experiments conducted at the Institute of Nuclear Energy Research (INER) Integral System Test (IIST) facility. Four tests were performed simulating break sizes of 0.2-2% (approximately corresponding to 1.25-4'' breaks for a referenced nuclear power plant) at cold-leg for assessing the PCCS capability in accident management. The key thermal-hydraulic phenomena to core heat removal for PCCS are observed and discussed. The experimental results show that the PCCS has successfully provided a continuous removal of core heat and a long term core cooling can be reached for all cases of SBLOCA.

  12. Computer modeling of a three-dimensional steam injection experiment

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S.; Castanier, L.M. [Stanford Univ., CA (United States). Petroleum Research Inst.

    1993-08-01

    The experimental results and CT scans obtained during a steam-flooding experiment with the SUPRI 3-D steam injection laboratory model are compared with the results obtained from a numerical simulator for the same experiment. Simulation studies were carried out using the STARS (Steam and Additives Reservoir Simulator) compositional simulator. The saturation and temperature distributions obtained and heat-loss rates measured in the experimental model at different stages of steam-flooding were compared with those calculated from the numerical simulator. There is a fairly good agreement between the experimental results and the simulator output. However, the experimental scans show a greater degree of gravity override than that obtained with the simulator for the same heat-loss rates. Symmetric sides of the experimental 5-spot show asymmetric heat-loss rates contrary to theory and simulator results. Some utility programs have been written for extracting, processing and outputting the required grid data from the STARS simulator. These are general in nature and can be useful for other STARS users.

  13. Experiments on Plasma Injection into a Centrifugally Confined System

    Science.gov (United States)

    Messer, S.; Bomgardner, R.; Brockington, S.; Case, A.; Witherspoon, F. D.; Uzun-Kaymak, I.; Elton, R.; Young, W.; Teodorescu, C.; Morales, C. H.; Ellis, R. F.

    2009-11-01

    We describe the cross-field injection of plasma into a centrifugally-confined system. Two different types of plasma railgun have been installed on the Maryland Centrifugal Experiment (MCX) in an attempt to drive that plasma's rotation. The initial gun was a coaxial device designed to mitigate the blowby instability. The second one was a MiniRailgun with a rectangular bore oriented so that the MCX magnetic field augments the railgun's internal magnetic field. Tests at HyperV indicate this MiniRailgun reaches much higher densities than the original gun, although muzzle velocity is slightly reduced. We discuss the impact of these guns on MCX for various conditions. Initial results show that even for a 2 kG field, firing the MiniRailgun modifies oscillations of the MCX diamagnetic loops and can impact the core current and voltage. The gun also has a noticeable impact on MCX microwave emissions. These observations suggest plasma enters the MCX system. We also compare diagnostic data collected separately from MCX for these and other guns, focussing primarily on magnetic measurements.

  14. Overdose experiences among injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Wood Evan

    2010-05-01

    Full Text Available Abstract Background Although previous studies have identified high levels of drug-related harm in Thailand, little is known about illicit drug overdose experiences among Thai drug users. We sought to investigate non-fatal overdose experiences and responses to overdose among a community-recruited sample of injection drug users (IDU in Bangkok, Thailand. Methods Data for these analyses came from IDU participating in the Mit Sampan Community Research Project. The primary outcome of interest was a self-reported history of non-fatal overdose. We calculated the prevalence of past overdose and estimated its relationship with individual, drug-using, social, and structural factors using multivariate logistic regression. We also assessed the prevalence of ever witnessing an overdose and patterns of response to overdose. Results These analyses included 252 individuals; their median age was 36.5 years (IQR: 29.0 - 44.0 and 66 (26.2% were female. A history of non-fatal overdose was reported by 75 (29.8% participants. In a multivariate model, reporting a history of overdose was independently associated with a history of incarceration (Adjusted Odds Ratio [AOR] = 3.83, 95% Confidence Interval [CI]: 1.52 - 9.65, p = 0.004 and reporting use of drugs in combination (AOR = 2.48, 95% CI: 1.16 - 5.33, p = 0.019. A majority (67.9% reported a history of witnessing an overdose; most reported responding to the most recent overdose using first aid (79.5%. Conclusions Experiencing and witnessing an overdose were common in this sample of Thai IDU. These findings support the need for increased provision of evidence-based responses to overdose including peer-based overdose interventions.

  15. Tangential and Vertical Compact Torus Injection Experiments on the STOR-M Tokamak

    Institute of Scientific and Technical Information of China (English)

    Xiao Chijin; Liu D.; S. Livingstone; A. K. Singh; E. Zhang; A. Hirose

    2005-01-01

    This paper describes the setup and results of compact torus (CT) injection experiments on the STOR-M tokamak. Tangential CT injection into STOR-M induced H-mode-like phenomena including doubling the electron density, reduction in the Ha radiation level, suppression of the floating potential fluctuations, suppression of the m = 2 Mirnov oscillations, and increase in the global energy confinement time. Experimental setup, bench-test results, and some preliminary injection data for vertical CT injection experiments on STOR-M will be shown. In addition, numerical simulations of the CT trajectories in tokamak discharges for both tangential and vertical injection geometries will be discussed.

  16. Progestogen-only injectable contraceptive: Experience of women in ...

    African Journals Online (AJOL)

    menstrual pattern are a well known side effect of this effective contraceptive method. .... For most teenagers requesting contraceptive, ... Injectables offer the advantage of not requiring ... insertion, and the combined oral contraceptive pills.

  17. Injection safety for immunisation--Andhra Pradesh experience.

    Science.gov (United States)

    Kaipilyawar, Satish B; Rao, R Gopal Krishna

    2005-04-01

    Injection safety is one component of a major immunisation project being implemented in partnership with Government of Andhra Pradesh and PATH, an international NGO. Prior to the project wrong and dangerous injection giving practices were present among the staff which needed immediate attention. It was decided to introduce auto disable syringes along with safety boxes with high quality training to staff and make all these available to all districts along with hepatitis B introduction in the routine immunisation. The State of Andhra Pradesh became the first to implement 'bundling' concept in the immunisation project. Implementation was planned to be done in a phased manner to cover all the 23 districts over a five-year period. For routine immunisation sessions, smaller locally produced boxes may be more acceptable. The Government of India made a decision on 21st July, 2004 on implementing injection safety. Injection safety and proper disposal of used needles and syringes can be successfully advocated if medical associations, paediatric associations, key governmental bodies and international agencies come together. PATH established a group and holds the secretariat for the India injection safety coalition on similar basis as the Safe Injection Global Network of WHO (SIGN). Description of AP system for safe disposal of needles and syringes using manual needle-cutters and plastics recycling has been depicted in this article.

  18. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders;

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  19. Environmental assessment: tar sand in situ steam injection experiment

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    A field experiment is planned for the in situ recovery of bitumen from tar sand. The site is located on a ten acre site 6.5 miles West of Vernal, Utah, and the experiment will last about six months. The experiment will utilize steam to lower the viscosity of the bitumen and drive it into production wells where it is recovered. Due to the small scale of this experiment, the impact of the proposed action will be minimal. Impact on local biological life will be minimal. The experiment will have no effect on aquatic habitats. No rare or endangered biological species will be affected by the experiment.

  20. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  1. Deportation experiences of women who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Robertson, Angela M; Lozada, Remedios; Vera, Alicia; Palinkas, Lawrence A; Burgos, José Luis; Magis-Rodriguez, Carlos; Rangel, Gudelia; Ojeda, Victoria D

    2012-04-01

    Deportation from the United States for drug offenses is common, yet the consequences of deportation for women drug users are poorly documented. In 2008, in Tijuana, Mexico, we conducted an exploratory qualitative study of migration, deportation, and drug abuse by interviewing 12 Mexican injection-drug-using women reporting U.S. deportation. Women reported heavy drug use before and after deportation, but greater financial instability and physical danger following deportation than when in the United States. We identified an unmet need for health and social services among deported drug-using women, including HIV prevention, drug treatment, physical and mental health services, and vocational training. Binational coordination is needed to help deported women resettle in Mexico.

  2. Deportation Experiences of Women Who Inject Drugs in Tijuana, Mexico

    Science.gov (United States)

    Robertson, Angela M.; Lozada, Remedios; Vera, Alicia; Palinkas, Lawrence A.; Burgos, José Luis; Magis-Rodriguez, Carlos; Rangel, Gudelia; Ojeda, Victoria D.

    2013-01-01

    Deportation from the United States for drug offenses is common, yet the consequences of deportation for women drug users are poorly documented. In 2008, in Tijuana, Mexico, we conducted an exploratory qualitative study of migration, deportation, and drug abuse by interviewing 12 Mexican injection-drug-using women reporting U.S. deportation. Women reported heavy drug use before and after deportation, but greater financial instability and physical danger following deportation than when in the United States. We identified an unmet need for health and social services among deported drug-using women, including HIV prevention, drug treatment, physical and mental health services, and vocational training. Binational coordination is needed to help deported women resettle in Mexico. PMID:21917563

  3. Current drive experiments in the Helicity Injected Torus - II

    Science.gov (United States)

    Hamp, W. T.; Redd, A. J.; Jarboe, T. R.; Nelson, B. A.; O'Neill, R. G.; Raman, R.; Sieck, P. E.; Smith, R. J.; Mueller, D.

    2006-10-01

    The HIT-II spherical torus (ST) device has demonstrated four toroidal plasma current drive configurations to form and sustain a tokamak: 1) inductive (ohmic) current drive, 2) coaxial helicity injection (CHI) current drive, 3) CHI initiated plasmas with ohmic sustainment (CHI+OH), and 4) ohmically initiated plasmas with CHI edge current drive (OH+ECD). CHI discharges with a sufficiently high ratio of injector current to toroidal field current form a closed flux core, and amplify the injector poloidal flux through magnetic reconnection. CHI+OH plasmas are more robust than unassisted ohmic discharges, with a wider operating space and more efficient use of the transformer Volt-seconds. Finally, edge CHI can enhance the plasma current of an ohmic discharge without significantly degrading the quality of the discharge. Results will be presented for each HIT-II operating regime, including empirical performance scalings, applicable parametric operating spaces, and requirements to produce these discharges. Thomson scattering measurements and EFIT simulations are used to evaluate confinement in several representative plasmas. Finally, we outline extensions to the HIT-II CHI studies that could be performed with NSTX, SUNIST, or other ST devices.

  4. Visualizing aerosol-particle injection for diffractive-imaging experiments

    CERN Document Server

    Awel, Salah; Eckerskorn, Niko; Wiedorn, Max; Horke, Daniel A; Rode, Andrei V; Küpper, Jochen; Chapman, Henry N

    2015-01-01

    Delivering sub-micrometer particles to an intense x-ray focus is a crucial aspect of single-particle diffractive-imaging experiments at x-ray free-electron lasers. Enabling direct visualization of sub-micrometer aerosol particle streams without interfering with the operation of the particle injector can greatly improve the overall efficiency of single-particle imaging experiments by reducing the amount of time and sample consumed during measurements. We have developed in-situ non-destructive imaging diagnostics to aid real-time particle injector optimization and x-ray/particle-beam alignment, based on laser illumination schemes and fast imaging detectors. Our diagnostics are constructed to provide a non-invasive rapid feedback on injector performance during measurements, and have been demonstrated during diffraction measurements at the FLASH free-electron laser.

  5. VLF wave injection experiments from Siple Station, Antarctica

    OpenAIRE

    R.A., Helliwell

    1987-01-01

    The background of VLF wave-particle experiments from Siple Station, Antarctica, including wave-induced precipitation is briefly reviewed. Single frequency ducted signals that exceed a certain 'threshold' intensity are observed at the conjugate point (Roberval, Quebec) to be amplified 30-50dB, with temporal growth rates of 30-200dB/s. Following saturation, variable frequency emissions are triggered. When a second signal is added to the first, with a frequency spacing Df

  6. Injecting learning experience into geoethics for human and natural sustainability

    Science.gov (United States)

    Crookall, David

    2016-04-01

    Our early life experience has a strong influence on our actions in later life. Humans today are just starting to re-learn, collectively, how to treat Earth with the respect that it deserves and that is needed for our offspring to inherit a decent home. However, we still have a long way to go to instill in people at large the ethics, knowledge and skills necessary to ensure a healthy journey for humanity on spaceship. The experience of early upbringing, of schooling and of everyday life is probably the only path strong enough to develop in people a strong desire for ethical behaviour towards their environment. The problem is that the measures taken today to ensure the development of ethical behaviours in the population at large are woefully inadequate. At best, western school programmes contain a few lessons devoted to the environment, and even then they usually just pay lip service to the basics of the environment; they rarely aim to instill skills and knowledge in order to understand and care deeply for the environment. My presentation will suggest some practical ways to help communities build ethical frameworks and strategies to guide and generate tools, methods and activities that guide young people (pupils, students, scholars, researchers) to toward more ethical behaviours regarding their environment and their communities. Examples might include: - Developing geoethical dimensions of internships, in all areas; - Designing, testing and running simulation/games+debriefing providing a rich affective-cognitive context for grappling with geoethical problems- eg, FISH BANKS, KEEP COOL. - Pressuring governments to make geoethics, environmental care and climate change understanding central components of (almost) all educational programmes (in, eg, history, language, business, law, medicine, etc). - Subsidizing environmental-care summer schools for families and teachers at all levels. - Etc. One of my actions is founding a academic journal in the area, maybe with the

  7. Three-dimensional modelling of an injection experiment in the anaerobic part of a landfill plume

    DEFF Research Database (Denmark)

    Juul Petersen, Michael; Engesgaard, Peter Knudegaard; Bjerg, Poul Løgstrup

    1998-01-01

    Analytical and numerical three-dimensional (3-D) simulations have been conducted and compared to data obtained from a large-scale (50 m), natural gradient field injection experiment. Eighteen different xenobiotic compounds (i.e. benzene, toluene, o-xylene, naphthalene, 1,1,1-TCA, PCE, and TCE......) and bromide as a conservative tracer, were for 195 days injected in the anaerobic part of the leachate plume downgradient of the Grindsted Landfill, Denmark. The injection area is an unconfined sandy aquifer with heterogeneities of clay and silt layers. Simulations with homogeneous and heterogeneous hydraulic...

  8. An enhancement of plasma density by neutral gas injection observed in SEPAC Spacelab-1 experiment

    Science.gov (United States)

    Sasaki, S.; Kawashima, N.; Kuriki, K.; Yanagisawa, M.; Obayashi, T.; Kubota, S.; Roberts, W. T.; Reasoner, D. L.; Taylor, W. W. L.; Williamson, P. R.

    1985-01-01

    An enhancement of plasma density observed during a neutral gas injection in Space Experiments with Particle Accelerators by the Space Shuttle/Spacelab-1 is presented. When a plume of nitrogen gas was injected from the orbiter into space, a large amount of plasma was detected by an onboard plasma probe. The observed density often increased beyond the background plasma density and was strongly dependent on the attitude of the orbiter with respect to the velocity vector. This effect has been explained by a collisional interaction between the injected gas molecules and the ionospheric ions relatively drifting at the orbital speed.

  9. Fate of herbicides in a shallow aerobic aquifer: A continuous field injection experiment (Vejen,Denmark)

    DEFF Research Database (Denmark)

    Broholm, Mette; Rügge, K.; Tuxen, Nina

    2001-01-01

    A continuous, natural gradient, field injection experiment, involving six herbicides and a tracer, was performed in a shallow aerobic aquifer near Vejen, Denmark. Bentazone, ()-2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP), dichlorprop, isoproturon, and the dichlobenil metabolite 2,6-dichlor......, with selected individual points for a longer period. The bromide plume followed a complex path through the monitoring network downgradient of the injection wells. The plume movement was controlled by spatially varied hydraulic conductivities of the sand deposit and influenced by asynchronous seasonal variation...... in groundwater potentials. An average flow velocity of 0.5 m/d was observed, as depicted by bromide. Bentazone, BAM, MCPP, and dichlorprop retardation was negligible, and only slight retardation of isoproturon was observed in the continuous injection experiment and a preceding pulse experiment. No degradation...

  10. Three-dimensional spiral injection scheme for the g-2/EDM experiment at J-PARC

    Science.gov (United States)

    Iinuma, Hiromi; Nakayama, Hisayoshi; Oide, Katsunobu; Sasaki, Ken-ichi; Saito, Naohito; Mibe, Tsutomu; Abe, Mitsushi

    2016-10-01

    A newly developed three-dimensional spiral injection scheme for beam insertion into a solenoidal storage ring is reported. A new planned muon g-2/EDM experiment at J-PARC aims to measure g - 2 to a factor of 5 better statistical precision and a factor of 100 better sensitivity for the electric dipole moment (EDM) measurement compared to previous experiments. The J-PARC experiment will use a 3-T MRI solenoid magnet as the muon storage ring with a 0.66 m diameter to achieve a 1-ppm level of local uniformity. The previous g - 2 injection scheme is not applicable for beam injection into a small ring. The new scheme provides a smooth injection utilizing a radial solenoidal fringe field, without causing an error field in the storage volume. The expected storage efficiency is 80% and over, which is to be compared to 3.5% for the previous g - 2 experiment. In addition, the ability to control the storage plane is important for the EDM measurement. In this paper, we introduce the conceptual design and required beam parameters in terms of Twiss functions and the expected injection efficiency.

  11. Designing Fault-Injection Experiments for the Reliability of Embedded Systems

    Science.gov (United States)

    White, Allan L.

    2012-01-01

    This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.

  12. Treatment of rectal prolapse in children with cow milk injection sclerotherapy: 30-year experience

    Science.gov (United States)

    Zganjer, Mirko; Cizmic, Ante; Cigit, Irenej; Zupancic, Bozidar; Bumci, Igor; Popovic, Ljiljana; Kljenak, Antun

    2008-01-01

    AIM: To evaluate the role and our experience of injection sclerotherapy with cow milk in the treatment of rectal prolapse in children. METHODS: In the last 30 years (1976-2006) we made 100 injections of sclerotherapy with cow milk in 86 children. In this study we included children who failed to respond to conservative treatment and we perform operative treatment. RESULTS: In our study we included 86 children and in all of the patients we perform cow milk injection sclerotherapy. In 95.3% (82 children) of patients sclerotherapy was successful. In 4 (4.7%) patients we had recurrent rectal prolapse where we performed operative treatment. Below 4 years we had 62 children (72%) and 24 older children (28%). In children who needed operative treatment we performed Thiersch operation and without any complications. CONCLUSION: Injection sclerotherapy with cow milk for treatment rectal prolapse in children is a simple and effective treatment for rectal prolapse with minimal complications. PMID:18205264

  13. Registration of ELF waves in rocket-satellite experiment with plasma injection

    Science.gov (United States)

    Korobeinikov, V. G.; Oraevskii, V. N.; Ruzhin, Iu. Ia.; Sobolev, Ia. P.; Skomarovskii, V. S.; Chmyrev, V. M.; Namazov, C. A.; Pokhunkov, A. A.; Nesmeianov, V. I.

    1992-12-01

    Two rocket KOMBI-SAMA experiments with plasma injection at height 100-240 km were performed in August 1987 in the region of Brazilian magnetic anomaly (L = 1.25). The launching time of the rocket was determined so that plasma injection was at the time when COSMOS 1809 satellite passed as close as possible to magnetic tube of injection. Caesium plasma jet was produced during not less than 300 s by an electric plasma generator separated from the payload. When the satellite passed the geomagnetic tube intersecting the injection region an enhancement of ELF emission at 140 Hz, 450 Hz by a factor of 2 was registered on board the satellite. An enhancement of energetic particle flux by a factor of 4-5 was registered on board the rocket. Observed ELF emission below 100 Hz is interpreted as the generation of oblique electromagnetic ion-cyclotron waves due to drift plasma instability at the front of the plasma jet.

  14. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  15. Simulation experiments to generate broadband chaos using dual-wavelength optically injected Fabry-Perot laser

    Science.gov (United States)

    Obaid, Hafiz Muhammad; Khawar Islam, Muhammad; Obaid Ullah, Muhammad

    2016-08-01

    Broadband chaos can be generated by beating two wavelengths in a hybrid arrangement of Fabry-Perot (FP) Laser and Fiber ring cavity by injecting dual wavelengths. The bandwidth of generated chaos can be controlled by detuning different modes of FP Laser for beating. The bandwidth of generated chaos increased to many folds depending upon the injected strength and wavelength spacing matched to FP laser modes. The bandwidth enhancement in different simulation experiments conducted is optimized by varying different parameters of FP laser and cavity. The waveforms are analyzed and Lyapunov exponents are calculated in order to validate the existence of high bandwidth non-pulsating chaos.

  16. Early results of microwave transmission experiments through an overly dense rectangular plasma sheet with microparticle injection

    Science.gov (United States)

    Gillman, Eric D.; Amatucci, W. E.

    2014-06-01

    These experiments utilize a linear hollow cathode to create a dense, rectangular plasma sheet to simulate the plasma layer surrounding vehicles traveling at hypersonic velocities within the Earth's atmosphere. Injection of fine dielectric microparticles significantly reduces the electron density and therefore lowers the electron plasma frequency by binding a significant portion of the bulk free electrons to the relatively massive microparticles. Measurements show that microwave transmission through this previously overly dense, impenetrable plasma layer increases with the injection of alumina microparticles approximately 60 μm in diameter. This method of electron depletion is a potential means of mitigating the radio communications blackout experienced by hypersonic vehicles.

  17. Analysis of Cavity Pressure and Warpage of Polyoxymethylene Thin Walled Injection Molded Parts: Experiments and Simulations

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2014-01-01

    , melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number......Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage...... was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure...

  18. Experiments and numerical analysis of a control method for natural circulation through helium gas injection

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuaki, E-mail: ttakeda@yamanashi.ac.jp; Hatori, Hirofumi; Funatani, Shumpei

    2016-09-15

    This study investigated a control method for natural circulation of air by helium gas injection. A depressurization accident is a design-basis accident of a very high temperature reactor. When a primary pipe rupture accident occurs, air is expected to enter the reactor pressure vessel from the breach. Thus, in-core graphite structures are oxidized. In order to predict and analyze the phenomena of air ingress during a depressurization accident, numerical analysis was carried out using a one-dimensional (1D) analysis code and three-dimensional computational fluid dynamics (3D CFD). An experiment was carried out regarding natural circulation using a circular pipe consisting of a reverse U-shaped channel. The channel consisted of two vertical heated and cooled pipes. The temperature difference between the vertical pipes was maintained at 40–80 K, and a small amount of helium gas was injected into the channel. The injected volume of helium was about 3.1–12.5% of the total channel volume. After injecting helium gas, each component gas moved through molecular diffusion and very weak natural circulation. After approximately 1180 s, ordinary natural circulation of air was suddenly produced. The numerical results of the 3D CFD code were in good agreement with the experimental results. The numerical results also showed that the natural circulation of air can be controlled by helium gas injection.

  19. An anaerobic field injection experiment in a landfill leachate plume (Grindsted, Denmark)

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Bjerg, Poul Løgstrup; Ludvigsen, L.

    1999-01-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15–60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment...... to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during...... the experimental period of 924 days owing to variations in the leachate from the landfill. However, no indication of change in the redox environment resulting from the field injection experiment or natural variation was observed in the individual sampling points. The methane, Fe(II), hydrogen, and VFA groundwater...

  20. Part weight verification between simulation and experiment of plastic part in injection moulding process

    Science.gov (United States)

    Amran, M. A. M.; Idayu, N.; Faizal, K. M.; Sanusi, M.; Izamshah, R.; Shahir, M.

    2016-11-01

    In this study, the main objective is to determine the percentage difference of part weight between experimental and simulation work. The effect of process parameters on weight of plastic part is also investigated. The process parameters involved were mould temperature, melt temperature, injection time and cooling time. Autodesk Simulation Moldflow software was used to run the simulation of the plastic part. Taguchi method was selected as Design of Experiment to conduct the experiment. Then, the simulation result was validated with the experimental result. It was found that the minimum and maximum percentage of differential of part weight between simulation and experimental work are 0.35 % and 1.43 % respectively. In addition, the most significant parameter that affected part weight is the mould temperature, followed by melt temperature, injection time and cooling time.

  1. New Generation of ELF/VLF Wave Injection Experiments for HAARP

    Science.gov (United States)

    Sonwalkar, V. S.; Reddy, A.; Watkins, B. J.

    2016-12-01

    We present a ray tracing study to investigate the feasibility of a new generation of wave injection experiments from HAARP transmitter (L 4.9). Highly successful whistler mode wave injection experiments from SIPLE station, Antarctica, have established the importance of such experiments to study magnetospheric wave-particle interactions, and for cold and hot plasma diagnostics [Helliwell and Katsufrakis, 1974; Carpenter and Miller, 1976; Sonwalkar et al., 1997]. Modulated heating experiments from HAARP have shown that it is possible to launch ELF/VLF waves into the magnetosphere that can be observed on the ground after one-, two-, and multi-hop ducted propagation [Inan et al., 2004]. Recent research has also shown that ionospheric heating experiments using HAARP can lead to the formation of magnetospheric ducts [e.g. Milikh et al., 2010; Fallen et al., 2011]. Collectively, these results indicate that the HAARP (or similar) transmitter can be used first to form ducts on nearby L shells, and then to inject and trap transmitter generated ELF/VLF waves in those ducts. Ray tracing studies using a model magnetosphere shows that ELF/VLF waves in a few kilohertz range can be trapped in ducts with L shells near the HAARP transmitter. For example, 1.5 kHz waves injected from L shell = 4.9 and altitude = 200 km can be trapped in ducts located within 0.3 L of the transmitter L-shell. The duct parameters needed for ray-trapping are typically duct width dL 0.1-0.3 and duct enhancement factor dNe/Ne 10-20% or more. The location of plasmapause with respect to transmitter plays a role in the nature of trapping. The duct locations and parameters required for trapping ELF/VLF waves inside the ducts are consistent with past observations of ducts generated by the HAARP transmitter. Ray tracing calculations provide trapped wave normal angles, time delays, resonant energetic electron energy, estimates of wave intensity inside the duct, on the ground, and on satellites such DEMETER, Van

  2. Fat injection to correct contour deformities of the reconstructed breast: a single surgeon experience

    Directory of Open Access Journals (Sweden)

    Youssef Tahiri

    2015-06-01

    Full Text Available Aim: Autologous fat grafting has gained acceptance as a technique to improve aesthetic outcomes in breast reconstruction. The purpose of this study was to share our clinical experience using autologous fat injection to correct contour deformities during breast reconstruction. Methods: A single surgeon, prospectively maintained database of patients who underwent autologous fat injection during breast reconstruction from January 2008 to November 2013 at McGill University Health Center was reviewed. Patient characteristics, breast history, type of breast reconstruction, volume of fat injected, and complications were analyzed. Results: One hundred and twenty-four patients benefited from autologous fat injection from January 2008 to November 2013, for a total of 187 treated breasts. The patients were on average 49.3 years old (΁ 8.9 years. Fat was harvested from the medial thighs (20.5%, flanks (39.1%, medial thighs and flanks (2.9%, trochanters (13.3%, medial knees (2.7%, and abdomen (21.9%. An average of 49.25 mL of fat was injected into each reconstructed breast. A total of 187 breasts in 124 patients were lipo-infiltrated during the second stage of breast reconstruction. Thirteen breasts (in 12 separate patients were injected several years after having undergone lumpectomy and radiotherapy. Of the 187 treated breasts, 118 were reconstructed with expanders to implants, 45 with deep inferior epigastric perforator flaps, 9 with latissimus dorsi flaps with implants, 4 with transverse rectus abdominis myocutaneous flaps, and 13 had previously undergone lumpectomy and radiotherapy. Six complications were noted in the entire series, for a rate of 3.2%. All were in previously radiated breasts. Average follow-up time was 12 months (range: 2-36 months. Conclusion: Fat injection continues to grow in popularity as an adjunct to breast reconstruction. Our experience demonstrates a low complication rate as compared to most surgical interventions of the breast

  3. Analysis of cavity pressure and warpage of polyoxymethylene thin walled injection molded parts: Experiments and simulations

    Science.gov (United States)

    Guerrier, P.; Tosello, G.; Hattel, J. H.

    2015-05-01

    Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure, melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number of conclusions concerning improvements to simulation accuracy are presented regarding: pvT data, mesh, short shots, cavity pressure for process control validation as well as molding machine geometry modelling. Eventually, a methodology for improved molding simulations of cavity injection pressure, filling pattern and warpage was established.

  4. Numerical analysis of experiments with gas injection into liquid metal coolant

    Science.gov (United States)

    Usov, E. V.; Lobanov, P. D.; Pribaturin, N. A.; Mosunova, N. A.; Chuhno, V. I.; Kutlimetov, A. E.

    2016-10-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results.

  5. Charge-carrier relaxation in disordered organic semiconductors studied by dark injection: Experiment and modeling

    Science.gov (United States)

    Mesta, M.; Schaefer, C.; de Groot, J.; Cottaar, J.; Coehoorn, R.; Bobbert, P. A.

    2013-11-01

    Understanding of stationary charge transport in disordered organic semiconductors has matured during recent years. However, charge-carrier relaxation in nonstationary situations is still poorly understood. Such relaxation can be studied in dark injection experiments, in which the bias applied over an unilluminated organic semiconductor device is abruptly increased. The resulting transient current reveals both charge-carrier transport and relaxation characteristics. We performed such experiments on hole-only devices of a polyfluorene-based organic semiconductor. Modeling the dark injection by solving a one-dimensional master equation using the equilibrium carrier mobility leads to a too-slow current transient, since this approach does not account for carrier relaxation. Modeling by solving a three-dimensional time-dependent master equation does take into account all carrier transport and relaxation effects. With this modeling, the time scale of the current transient is found to be in agreement with experiment. With a disorder strength somewhat smaller than extracted from the temperature-dependent stationary current-voltage characteristics, also the shape of the experimental transients is well described.

  6. Effects of Water Injection into Fractured Geothermal Reservoirs: A Summary of Experience Worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Roland N.

    1982-06-01

    Reinjection of water into fractured geothermal reservoirs holds potential both for improvement and degradation of total energy recovery. The replacement of reservoir fluid can mean support of placement of reservoir pressures and also more efficient thermal energy recovery, but at the same time the premature invasion of reinjected water back into production wells through high permeability fractures can reduce discharge enthalpy and hence deliverability and useful energy output. Increases in reservoir pressure and maintenance of field output have been observed in operating fields, but unfortunately so too have premature thermal breakthroughs. The design of reinjection schemes, therefore, requires careful investigation into the likely effects, using field experimentation. This paper summarizes field experience with reinjection around the world, with the intention of elucidating characteristics of possible problems. The results summarized in this paper fall into three categories of interest: permeability changes dye to injection (both increases and decreases); the path followed by injected water (as indicated by tracer tests); and the thermal and hydraulic influences of injection on the reinjection well itself and on surrounding producers. [DJE-2005

  7. Design calculations for a combined ventilation and brine injection experiment at the Grimsel Rock Laboratory, Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Finsterle, S.; Pruess, K.

    1993-07-01

    A combined ventilation and brine injection test is planned at the Grimsel Test Site. The objective of the experiment is to study the transport of liquid and gas in the vicinity of a ventilated drift in order to evaluate the impact of the drying process on the characterization of the rock matrix. The proposed test sequence includes a desaturation-resaturation cycle. In addition, brine and fresh water will be injected from a borehole as trace electrolytes in order to better track the propagation of the individual phases. Results of design calculations using the TOUGH2 code show that injection of brine may significantly influence the unsaturated flow behavior by changing the pressure and saturation distribution around the borehole. Transport velocity is predicted to be very slow, requiring several months for the brine to reach the draft wall. However, the presence of preferential flow paths may reduce travel time and alter brine content and saturation distribution so that certain sensors may respond earlier or not at all.

  8. The Experiment Research of Subconjunctival Injections with Etoposide for the Treatment of Retinoblastoma Mice

    Institute of Scientific and Technical Information of China (English)

    Yuxiang Mao; Zhongyao Wu; Huasheng Yang; Jianliang Zheng; Jianfeng He; Wei Li

    2005-01-01

    Purpose: To evaluate the efficacy of subconjunctival injections of Etoposide for retinoblastoma(RB) mice.Method: Twenty-five RB mice were divided into 5 groups for the study(G0~G4). GO for control group received 0.9% sodium chloride injection subconjunctival. G1: 5 RB mice for systemic delivery received 6 systemic administration of Etoposide 150 μg and Cyclosporin A (CSA)1.0mg at 3 days intervals, respectively. G2~G4:5 RB mice in each group received 6 subconjunctival delivery of Etoposide in 50、75、150μg at 3 days intervals, respectively.To observe the changes of the volume of RB in anterior chamber and the part of conjunctiva for injections of chemotherapeutic drugs. All eyes and conjunctiva and scleras of the part for drugs injections were obtained at 6 weeks after experiment for histopathologic examination. The findings under the light microscope were analysed with software to measure the areas of RB in anterior chambers and the tumor inhibition rate.Results:The volume of RB in anterior chambers for G1 and G2 increase quickly and none of the mice exhibited tumor control. The RB volume increase slowly in G3 and exhibit tumor control in G4. The areas of tumors in G0~G4 are 0.710,0.659,0.634,0.515,0.235 mm2, respectively. The rate for tumor inhibition in G0~G4 are 0.0%,7.18%, 10.70% ,27.43% ,66.90%, respectively. There are statistical significant difference between the G1 and G4 for the volumes of tumors and the rate of tumor inhibition.The pathologic examination of subconjunctiva and sclera for the injective sites showed no pathologic changes.Conclusions: There are significant effects for the method of subconjunctival delivery of Etoposide in RB control, demonstrating a positive dose-related relationship. Subconjunctival injection of Etoposide reached better efficacy in controlling and inhibiting RB cells than systemic delivery of Etoposide for the same dose. The pathologic results showed the subconjunctival delivery of etoposide were safety for

  9. Incarceration experiences among a community-recruited sample of injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Lai Calvin

    2009-12-01

    Full Text Available Abstract Background Since 2003 Thailand has waged an aggressive "war on drugs" campaign focused on arresting and incarcerating suspected drug users and dealers. However, little is known about incarceration experiences among IDU in the wake of the recent war on drugs. Therefore, we sought to examine incarceration experiences among IDU in Bangkok, Thailand. Methods We examined the prevalence of incarceration among community-recruited IDU participating in the Mitsampan Community Research Project. Multivariate logistic regression was used to identify factors associated with a self-reported history of incarceration. We also examined the prevalence of injection drug use and syringe sharing within prisons. Results 252 IDU were recruited in August 2008; 66 (26.2% were female and the median age was 36.5 years. In total, 197 (78.2% participants reported a history of incarceration. In multivariate analyses, reporting a history of incarceration was associated with a history of compulsory drug treatment (adjusted odds ratio [AOR] = 4.93; 95% confidence interval [CI]: 1.95 - 12.48, non-fatal overdose (AOR = 3.69; 95%CI: 1.45 - 9.39, syringe sharing (AOR = 2.20; 95%CI: 1.12 - 4.32, and female gender (AOR = 0.41; 95%CI: 0.20 - 0.82. Among those who reported a history of incarceration, 59 (29.9% reported injection drug use in prison, and 48 (81.4% of these individuals reported sharing syringes in prison. Incarceration was not associated with the number of injections performed in the previous week (p = 0.202. Conclusion Over three-quarters of the IDU participating in this study reported a history of incarceration, and 30% of these individuals reported injection drug use within prison. Further, an alarmingly high level of syringe sharing within prison was reported, and incarceration was not associated with reductions in drug use. These findings provide further evidence of the need for community diversion strategies, as well as harm reduction programs, in Thai

  10. Investigation of oil injection into brine for the strategic petroleum reserve : hydrodynamics experiments with simulant liquids.

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Jaime N.; Shollenberger, Kim Ann (California Polytechnic State University, San Luis Obispo, CA); Torczynski, John Robert; Cote, Raymond O.; Barney, Jeremy; O' Hern, Timothy John

    2003-10-01

    An experimental program is being conducted to study a proposed approach for oil reintroduction in the Strategic Petroleum Reserve (SPR). The goal is to assess whether useful oil is rendered unusable through formation of a stable oil-brine emulsion during reintroduction of degassed oil into the brine layer in storage caverns. This report documents the first stage of the program, in which simulant liquids are used to characterize the buoyant plume that is produced when a jet of crude oil is injected downward from a tube into brine. The experiment consists of a large transparent vessel that is a scale model of the proposed oil injection process at the SPR. An oil layer is floated on top of a brine layer. Silicon oil (Dow Corning 200{reg_sign} Fluid, 5 cSt) is used as the simulant for crude oil to allow visualization of the flow and to avoid flammability and related concerns. Sodium nitrate solution is used as the simulant for brine because it is not corrosive and it can match the density ratio between brine and crude oil. The oil is injected downward through a tube into the brine at a prescribed depth below the oil-brine interface. Flow rates are determined by scaling to match the ratio of buoyancy to momentum between the experiment and the SPR. Initially, the momentum of the flow produces a downward jet of oil below the tube end. Subsequently, the oil breaks up into droplets due to shear forces, buoyancy dominates the flow, and a plume of oil droplets rises to the interface. The interface is deflected upward by the impinging oil-brine plume. Two different diameter injection tubes were used (1/2-inch and 1-inch OD) to vary the scaling. Use of the 1-inch injection tube also assured that turbulent pipe flow was achieved, which was questionable for lower flow rates in the 1/2-inch tube. In addition, a 1/2-inch J-tube was used to direct the buoyant jet upwards rather than downwards to determine whether flow redirection could substantially reduce the oil-plume size and the

  11. Mesigyna once-a-month combined injectable contraceptive: experience in Latin America.

    Science.gov (United States)

    Bassol, S; Cravioto, M C; Durand, M; Bailon, R; Carranza, S; Fugarolas, J; Gaona, R; Parada, L M; Celis, C; Santoyo, S; Garza-Flores, J; Vazquez, L; Lopez, C; Gurucharri, C; Novelli, J; Carneiro de Oliveira, H; Mendez, J; de Andrade, M E; de Mello, N R; de Melo, K; Chada, E; Yassle, M E; Castañeda, A; Gomez, P; Arboleda, C; Trujillo, L; Bucheli, R; Hidalgo, I; Olavide, R; Parejarios, J; Succar, J; Reyes-Marquez, R; Albrecht, G

    2000-05-01

    A phase III clinical study was carried out among 534 fertile Latin American women to evaluate cycle control, side effects, and contraceptive efficacy of a once-a-month combined injectable, Mesigyna, consisting of 50 mg norethisterone enanthate and 5 mg estradiol valerate. The pregnancy rate at 1 year was 0 per 100 woman-years for a total experience of 4688 woman-months. The overall discontinuation rate at one year was 17.9%. Discontinuation rate for bleeding problems was 5.1%. The Colombian women had a significant increase (p <0.001) in bleeding problems compared to other countries. The discontinuation rate for amenorrhea was 1.1%. There were no significant differences between the groups regarding discontinuation for other medical or non-medical reasons. Mean weight gain after one year of use was 1.02 kg. Mesigyna is an appropiate once-a-month injectable contraceptive for Latin American women since it is highly effective and its perception of normal menstrual bleeding is of importance in the Latin American population.

  12. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego.

    Science.gov (United States)

    Wood, Emily F; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Cuevas Mota, Jazmine; Garfein, Richard S; Strathdee, Steffanie A; Wagner, Karla D

    2017-03-01

    powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. The pharmacodynamics experiment of XinHua injection protect action of ADR-induced toxin myocarditisin mice

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong; DU Jia-lin; LI Xin-hua; XIANG Shao-jie; JIA Dong; BAO Yu-long; LI Kun

    2008-01-01

    Objective The experiment is to study the protective effects of Xinkang Injection on ADR-induced toxin myocarditisin mice. Methods The test of Xinkang Injection on ADR-induced toxin myocarditisin mice. Firstly, the animal of obnormal, weight and death rate. Secondly, the influnences of cardiogram of ADR-induced toxin myocarditisin mice. Thirdly, the influnences of lactate dehydrogenase (LDH), creatine kinase (CK) and glutamic oxaloacetic transaminasw (GOT) of ADR-induced toxin myocarditisin mice. Fouthly, the influnences of changes of cardioc pathological mechanism of ADR-induced toxin myocarditisin mice. Fifthly, the influnces of the caidioc ultrastructural of ADR-induced toxin myocarditisin mice. Results Firstly, to ADR-induced toxin myocarditisin mice, the weight of middle dose and high dose of Xinkang injection had declined obviosly which contrast with the constraction model mice team. In the mean time, the weight of Xinkang injection team had obviosly changde which contrast with contrastion mice team(P<0.01 ). Secondly, to ADR-induced toxin myocarditisin mice, the middle dose and high dose of Xinkang injection have obviosly withstand Q abnormal cardiogram, in the meantime, Xinkang injection team had obviosly changde contrast with the contrastion model mice (P<0.01 ). Thirdly, to ADR-induced toxin myocarditisin mice, The activity of lactate dehydrogenase(LDH),creatine kinase (CK) and glutamic oxaloacetic transaminasw (GOT) were differently measured. The middle dose and high dose of Xinkang injection team can obviously declined the activity of LDH and CK (P<0.01). Fouthly, to ADR-induced toxin myocarditisin mice, the low dose, the middle dose and high dose of Xinkang injection team can contrast w, ith injured on toxic myocarditisin mice cardioc. Fifthly, to ADR-induced toxin myocarditisin mice, the low dose , the middle dose and high dose of Xinkang injection team have effect of allevite the injection of the cardioc ulteasteuctural of ADR-induced toxin

  14. Laboratory Experiments on Environmental Friendly Means to Improve Coalbed Methane Production by Carbon Dioxide/Flue Gas Injection

    NARCIS (Netherlands)

    Mazumder, S.; Wolf, K.H.A.A.; Van Hemert, P.; Busch, A.

    2008-01-01

    Scaled in situ laboratory core flooding experiments with CO2, N2 and flue gas were carried out on coal in an experimental high P,T device. These experiments will be able to give an insight into the design of the injection system, management, control of the operations and the efficiency of an ECBM pr

  15. Laboratory Experiments on Environmental Friendly Means to Improve Coalbed Methane Production by Carbon Dioxide/Flue Gas Injection

    NARCIS (Netherlands)

    Mazumder, S.; Wolf, K.H.A.A.; Van Hemert, P.; Busch, A.

    2008-01-01

    Scaled in situ laboratory core flooding experiments with CO2, N2 and flue gas were carried out on coal in an experimental high P,T device. These experiments will be able to give an insight into the design of the injection system, management, control of the operations and the efficiency of an ECBM

  16. Local mechanical properties of LFT injection molded parts: Numerical simulations versus experiments

    Science.gov (United States)

    Desplentere, F.; Soete, K.; Bonte, H.; Debrabandere, E.

    2014-05-01

    In predictive engineering for polymer processes, the proper prediction of material microstructure from known processing conditions and constituent material properties is a critical step forward properly predicting bulk properties in the finished composite. Operating within the context of long-fiber thermoplastics (LFT, length Autodesk Simulation Moldflow Insight 2014 software has been used. In this software, a fiber breakage algorithm for the polymer flow inside the mold is available. Using well known micro mechanic formulas allow to combine the local fiber length with the local orientation into local mechanical properties. Different experiments were performed using a commercially available glass fiber filled compound to compare the measured data with the numerical simulation results. In this investigation, tensile tests and 3 point bending tests are considered. To characterize the fiber length distribution of the polymer melt entering the mold (necessary for the numerical simulations), air shots were performed. For those air shots, similar homogenization conditions were used as during the injection molding tests. The fiber length distribution is characterized using automated optical method on samples for which the matrix material is burned away. Using the appropriate settings for the different experiments, good predictions of the local mechanical properties are obtained.

  17. A discrete choice experiment to determine patient preferences for injection devices in multiple sclerosis.

    Science.gov (United States)

    Shingler, S L; Swinburn, P; Ali, S; Perard, R; Lloyd, A J

    2013-08-01

    Relapsing-remitting multiple sclerosis (MS) is usually managed with disease modifying drugs (DMDs), most commonly administered via self-injection. The aim of this study was to estimate the influence that different treatment-related attributes have for MS patients on their choice of MS DMD device. By establishing the relative importance of these characteristics for patients it should be possible to better understand the acceptability of a given device and to optimize the development of future devices. A discrete choice experiment (DCE) survey was developed on the basis of a review of published literature. Attributes identified for inclusion in the survey were: ease of use; comfort of use; presence of additional functions, needle visibility; practicality and efficacy. Choice sets were presented as pairs of hypothetical treatments based upon a fractional factorial design. One-hundred device-using MS patients completed the survey online. Analysis was conducted using a mixed-logit approach. Analysis of the DCE data revealed that all attributes significantly predicted treatment choice. Efficacy exhibited the largest effect on treatment selection and this provided context for understanding the magnitude of impact for the other attributes. Reducing the discomfort associated with device use and eliminating the necessity for assembly or drug reconstitution were highly valued. The addition of reminder and time-stamping functions, improved needlestick injury prevention, and reduction in device size were secondary concerns but still deemed desirable. Efficacy is of primary importance to MS patients, but characteristics of drug delivery devices can play an important role in treatment decision-making. Not all device characteristics could be included, and results are based upon 100 participants only. Findings suggest there is significant potential value in developing self-injection devices that are not only efficacious but also convenient and comfortable to use. Reducing barriers

  18. Simulation of field injection experiments in heterogeneous unsaturated media using cokriging and artificial neural network

    Science.gov (United States)

    Ye, Ming; Khaleel, Raziuddin; Schaap, Marcel G.; Zhu, Jianting

    2007-07-01

    Simulations of moisture flow in heterogeneous soils are often hampered by lack of measurements of soil hydraulic parameters, making it necessary to rely on other sources of information. In this paper, we develop a methodology to integrate data that can be easily obtained (for example, initial moisture content, θi, bulk density, and soil texture) with data on soil hydraulic properties via cokriging and Artificial Neural Network (ANN)-based pedotransfer functions. The method is applied to generate heterogeneous soil hydraulic parameters at a field injection site in southeastern Washington State. Stratigraphy at the site consists of imperfectly stratified layers with irregular layer boundaries. Cokriging is first used to generate three-dimensional heterogeneous fields of bulk density and soil texture using an extensive data set of field-measured θi, which carry signature about site heterogeneity and stratigraphy. Soil texture and bulk density are subsequently input into an ANN-based site-specific pedotransfer function to generate three-dimensional heterogeneous soil hydraulic parameter fields. The stratigraphy at the site is well represented by the estimated pedotransfer variables and soil hydraulic parameters. The parameter estimates are then used to simulate a field injection experiment at the site. A relatively good agreement is obtained between the simulated and observed moisture contents. The spatial distribution pattern of observed moisture content as well as the southeastward moisture movement is captured well in the simulations. In contrast to earlier work using an effective parameter approach (Yeh et al., 2005), we are able to reproduce the observed splitting of the moisture plume in a coarse sand unit that is sandwiched between two fine-textured units. The simple method of combining cokriging and ANN for site characterization provides unbiased prediction of the observed moisture plume and is flexible so that additional measurements of various types can be

  19. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Hydrogeological characterization of the Heletz Sands Reservoir, Heletz (Israel) as a preliminary step towards CO2 injection experiments

    Science.gov (United States)

    Bensabat, Jacob; Niemi, Auli; Tsang, Chin-Fu; Sharma, Prabhakar; Carrera, Jesus; Sauter, Martin; Tatomir, Alexandru; Ghergut, Julia; Pezard, Philippe; Edlman, Katriona; Brauchler, Ralf

    2013-04-01

    Hydrogeological characterization of the Heletz Sands Reservoir, Heletz (Israel) as a preliminary step towards CO2 injection experiments One the major components of the EU-FP7 funded MUSTANG project is to conduct a highly controlled series of CO2 injection experiments, aimed at determining field values of key CO2 trapping mechanisms such as dissolution and residual trapping and to establish a comprehensive and consistent dataset for model validation. Prior to injecting CO2 there is a need to achieve a sufficient degree of hydrogeological characterization of the reservoir. In what follows we present a sequence of hydrologic tests to be conducted at Heletz and their expected contribution to the understanding relevant hydrogeology. These include: 1) Chemical characterization of the formation fluid; 2) Flowing Fluid Electrical Conductivity log, aimed at determining the vertical variability of the reservoir permeability in the near well vicinity; 3) Water pulse and pumping tests, aimed at determining the reservoir scale hydraulic properties; 4) Thermal test, aimed at determining the value of the heat transfer coefficient from the reservoir to the borehole fluid, which is responsible for the heating of injected fluid in the borehole; 5) two-well injection and pumping of water and tracers test, in order to determine the impact of heterogeneity on the hydraulic parameters and to identify preferential flow paths in the reservoir. This paper presents the design and planning of the experiments, the results obtained in field and a preliminary interpretation.

  1. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  2. Neutral Beam Injection System for the C-2W Field Reversed Configuration Experiment

    Science.gov (United States)

    Dunaevsky, Alexander; Ivanov, Alexander; Kolmogorov, Vyacheslav; Smirnov, Artem; Korepanov, Sergey; Binderbauer, Michl; TAE Team; BINP Team

    2016-10-01

    C-2U Field-Reversed Configuration (FRC) experiment proved substantial reduction in turbulence-driven losses via tangential neutral beam injection (NBI) coupled with electrically biased plasma guns at the plasma ends. Under such conditions, highly reproducible, advanced beam-driven FRCs were produced and sustained for times significantly longer (more than 5 ms) than all characteristic plasma decay times without beams. To further improve FRC sustainment and demonstrate the FRC ramp-up, the C-2U experimental device is undergoing a major upgrade. The upgrade, C-2W, will have a new NBI system producing a record total hydrogen beam power of 20 + MW in a 30ms pulse. The NBI system consists of eight positive-ion based injectors featuring flexible, modular design. Four out of eight NBI injectors have a capability to switch the beam energy during a shot from the initial 15 keV to 40 keV at a constant beam current. This feature allows to increase the beam energy and thereby optimize the beam-plasma coupling during the magnetic field ramp up. This presentation provides an overview of the C-2W NBI system, including the design of the switchable energy injectors, layout of the power supply system, and results of the prototype testing.

  3. Blood Trials: Transfusions, Injections, and Experiments in Africa, 1890-1920.

    Science.gov (United States)

    Sunseri, Thaddeus

    2016-07-01

    From about 1880 to 1920, a culture of medical experimentation promoted blood transfusion as a therapy for severe anemia in Europe, which was applied in German East Africa in 1892 for a case of blackwater fever, a complication of malaria afflicting mainly Europeans. This first case of blood transfusion in Africa, in which an African's blood was transfused into a German official, complicates the dominant narrative that blood transfusions in Africa came only after World War I. Medical researchers moreover experimented with blood serum therapies on human and animal subjects in Europe and Africa, injecting blood of different species, "races" and ethnicities into others to demonstrate parasite transmissibility and to discover vaccines for diseases such as malaria, sleeping sickness, and yellow fever. While research in German colonies is highlighted here, this was a transnational medical culture that crossed borders and oceans. This research is of interest as a possible early pathway for the epidemic spread of HIV and other zoonoses in Africa and the world, which biomedical researchers have identified as emerging in West-Central Africa sometime around the turn of the twentieth century.

  4. Experiences with Policing among People Who Inject Drugs in Bangkok, Thailand: A Qualitative Study

    Science.gov (United States)

    Hayashi, Kanna; Small, Will; Csete, Joanne; Hattirat, Sattara; Kerr, Thomas

    2013-01-01

    Background Despite Thailand's commitment to treating people who use drugs as “patients” not “criminals,” Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID) in Bangkok, Thailand, between 2008 and 2012. Methods and Findings Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample. Conclusions This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings

  5. Experiences with policing among people who inject drugs in Bangkok, Thailand: a qualitative study.

    Science.gov (United States)

    Hayashi, Kanna; Small, Will; Csete, Joanne; Hattirat, Sattara; Kerr, Thomas

    2013-12-01

    Despite Thailand's commitment to treating people who use drugs as "patients" not "criminals," Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID) in Bangkok, Thailand, between 2008 and 2012. Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample. This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings pertaining to the use of urine drug testing by police

  6. Experiences with policing among people who inject drugs in Bangkok, Thailand: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Kanna Hayashi

    2013-12-01

    Full Text Available Despite Thailand's commitment to treating people who use drugs as "patients" not "criminals," Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID in Bangkok, Thailand, between 2008 and 2012.Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample.This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings pertaining to the use of urine drug

  7. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  8. Feasibility study of a Single Well Injection Withdrawal (SWIW) experiment with synthetic groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Nordqvist, Rune; Byegaard, Johan; Hjerne, Calle (Geosigma AB, Uppsala (Sweden))

    2008-08-15

    This report describes the performance and results of a feasibility study regarding SWIW (Single Well Injection Withdrawal) tests with synthetic groundwater. The objectives of the study were to investigate the possibility to perform, analyse and evaluate SWIW tests with synthetic groundwater. SWIW tests with synthetic groundwater imply that water similar to the natural groundwater is produced but without one or several compounds that naturally occurs in the groundwater. The synthetic groundwater is injected into the rock formation and later pumped back. The increase of the naturally occurring compounds may be analysed and provide information about diffusion processes in the rock formation. Simulations of SWIW tests with synthetic groundwater shows that a combination of tests with and without a waiting period may provide good opportunities to distinguish between fast and slow diffusion processes, i.e. diffusion from stagnant zones and rock matrix. Furthermore, the simulations show that it is important to use many tracers with different characteristics regarding diffusion and sorption in order to facilitate the evaluation. If additional boreholes exist in the vicinity that may be used as observation holes for tracer breakthrough, it would be a great benefit for the evaluation of the tests. This study shows that it is possible to produce a synthetic groundwater of sufficient amount and purity to a reasonable cost at CLAB (Baslab). The starting point for the study was to use the test site TRUE Block Scale in the Aespoe tunnel. The study shows that the well characterized structures no 19 and 20 probably had been suitable for SWIW tests. However, during the feasibility study a project started that will result in a new tunnel in the vicinity of TRUE Block Scale. This implies that the site will not be accessible for experiments until 2009 at the earliest. The new tunnel may also change the hydraulic characteristics at the site so that it is no longer suitable for SWIW tests

  9. Validating An Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments

    Science.gov (United States)

    Catanzarite, Joseph; Burke, Christopher J.; Li, Jie; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    The Kepler Mission is developing an Analytic Completeness Model (ACM) to estimate detection completeness contours as a function of exoplanet radius and period for each target star. Accurate completeness contours are necessary for robust estimation of exoplanet occurrence rates.The main components of the ACM for a target star are: detection efficiency as a function of SNR, the window function (WF) and the one-sigma depth function (OSDF). (Ref. Burke et al. 2015). The WF captures the falloff in transit detection probability at long periods that is determined by the observation window (the duration over which the target star has been observed). The OSDF is the transit depth (in parts per million) that yields SNR of unity for the full transit train. It is a function of period, and accounts for the time-varying properties of the noise and for missing or deweighted data.We are performing flux-level transit injection (FLTI) experiments on selected Kepler target stars with the goal of refining and validating the ACM. “Flux-level” injection machinery inserts exoplanet transit signatures directly into the flux time series, as opposed to “pixel-level” injection, which inserts transit signatures into the individual pixels using the pixel response function. See Jie Li's poster: ID #2493668, "Flux-level transit injection experiments with the NASA Pleiades Supercomputer" for details, including performance statistics.Since FLTI is affordable for only a small subset of the Kepler targets, the ACM is designed to apply to most Kepler target stars. We validate this model using “deep” FLTI experiments, with ~500,000 injection realizations on each of a small number of targets and “shallow” FLTI experiments with ~2000 injection realizations on each of many targets. From the results of these experiments, we identify anomalous targets, model their behavior and refine the ACM accordingly.In this presentation, we discuss progress in validating and refining the ACM, and we

  10. Thermionic plasma injection for the Lockheed Martin T4 Compact Fusion Reactor experiment

    Science.gov (United States)

    Heinrich, Jonathon

    2015-11-01

    Lockheed Martin's Compact Fusion Reactor (CFR) concept relies on diamagnetic confinement in a magnetically encapsulated linear ring cusp geometry. Plasma injection into cusp field configurations requires careful deliberation. Previous work has shown that axial injection via a plasma gun is capable of achieving high-beta conditions in cusp configurations. We present a pulsed, high power thermionic plasma source and the associated magnetic field topology for plasma injection into the caulked-cusp magnetic field. The resulting plasma fueling and cross-field diffusion is discussed.

  11. Pitch angle scattering by triggered emissions from the Siple Station wave injection experiment

    Science.gov (United States)

    Harid, V.; Golkowski, M.; Bell, T. F.; Cohen, M.; Inan, U. S.

    2012-12-01

    Nonlinear amplification of whistler mode waves in the Earth's magnetosphere , due to gyroresonance with energetic electrons, also known as the phenomena of VLF triggered emissions, has been investigated extensively with analytical formulations, experimental observations and computer simulations. However, the pitch angle scattering of typical triggered emission waveforms has not been specifically considered. Most authors consider particle scattering either in the presence of a monochromatic constant amplitude wave or a broadband incoherent but time-frequency homogenous emission. Although investigation of these two limiting cases has provided valuable insight into radiation belt dynamics, a large class of waves including triggered emissions and chorus do not fall under either of the two descriptions. The inherent symmetry of a constant amplitude monochromatic wave around the equator results in non-cumulative pitch angle change for a large population of electrons. Wave amplification generated during linear and nonlinear growth result in wave gradients that can have a more significant effect on particle pitch angle and energy. In addition, coherent frequency changing signals are capable of shifting the cyclotron resonance condition and significantly perturbing particle trajectories from their adiabatic motion. The wave-injection experiment at Siple Station, Antarctica was designed to study wave growth and triggering processes in the magnetosphere. Amplified signals from Siple Station often show both wave gradients as well advances in phase and frequency. Using a numerical test-particle simulation, we model the effect of typical Siple Station signals on pitch angle scattering and particle precipitation. Results show that triggered emission type wave forms are more efficient in producing large pitch angle changes in resonant particles.

  12. Ultrasound-guided injection for the biceps brachii tendinitis: results and experience.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Lause, Gregory E

    2011-05-01

    The purpose of this study was to identify the results of ultrasound-guided injection of corticosteroid for biceps brachii tendinitis. In this randomized and prospective study, we evaluated 45 patients who were treated by free-hand injection without ultrasound guidance (group A) and 53 patients who were treated by ultrasound-guided injection (group B). The mean age was 47 y (range, 28 to 72). The average follow-up was 33 weeks (range, 24 to 56). The visual analog scale score decreased from 7.1 ± 2.3 before injection to 4.2 ± 3.1 at follow-up in group A and from 6.9 ± 2.6 to 2.1 ± 1.9 in group B (p biceps brachii tendinitis.

  13. Experience of drilling wells using pump-compressor unit to inject aerated fluid

    Energy Technology Data Exchange (ETDEWEB)

    Oleynik, S.P.; Beley, I.V.; Lopatin, Yu.S.; Pytel, S.P.; Vasilak, I.I.; Yushkevich, V.I.

    1979-01-01

    Results are described from drilling wells with flushing by highly aerated clay fluid with the help of a UNGA unit which includes pumps and compressors of the drilling unit UBSh-1 which permits injection of an aerated mixture under pressures considerably exceeding the pressure of its formation. Qualitative and technical-economic advantages of drilling with flushing by aerated solutions with the use of a unit for injecting gas-liquid agents are presented.

  14. INJECTING DRUG USERS’ EXPERIENCES OF POLICING PRACTICES IN TWO MEXICAN-U.S. BORDER CITIES: PUBLIC HEALTH PERSPECTIVES

    Science.gov (United States)

    Miller, Cari L.; Firestone, Michelle; Ramos, Rebeca; Burris, Scott; Ramos, Maria Elena; Case, Patricia; Brouwer, Kimberly C.; Fraga, Miguel Angel; Strathdee, Steffanie A.

    2008-01-01

    Background Previous research has identified the impact of law enforcement practices on the behaviors and health of injection drug users (IDUs). We undertook a qualitative study of IDUs’ experiences of policing practices in two Mexican cities on the U.S. border. Methods In 2004, two teams of Mexican interviewers conducted in-depth interviews with IDUs residing in Tijuana and Ciudad Juarez (Cd. Juarez), Mexico who had injected drugs at least once in the prior month. Topics included types of drug used, injection settings, access to sterile needles and experiences with police. Field notes and transcribed interviews were analyzed to identify emergent themes. Results Among the 43 participants, most reported that it is common for IDUs to be arrested and detained for 36 hours for carrying sterile or used syringes. Most reported that they or someone they knew had been beaten by police. Interviews suggested 5 key themes relating to police influence on the risk environment: 1) impact of policing practices on accessibility of sterile syringes, 2) influence of police on choice of places to inject drugs (e.g., shooting galleries), 3) police violence, 4) police corruption, and 5) perceived changes in policing practices. Conclusion Findings suggest that some behavior of police officers in Tijuana and Cd. Juarez is inconsistent with legal norms and may be negatively influencing the risk of acquiring blood-borne infections among IDUs. Implementing a comprehensive and successful HIV prevention program among IDUs requires interventions to influence the knowledge, attitudes and practices of law enforcement officers. PMID:17997089

  15. Investigation of oil injection into brine for the Strategic Petroleum Reserve : hydrodynamics and mixing experiments with SPR liquids.

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Jaime N.; Cote, Raymond O.; Torczynski, John Robert; O' Hern, Timothy John

    2004-05-01

    An experimental program was conducted to study a proposed approach for oil reintroduction in the Strategic Petroleum Reserve (SPR). The goal was to assess whether useful oil is rendered unusable through formation of a stable oil-brine emulsion during reintroduction of degassed oil into the brine layer in storage caverns. An earlier report (O'Hern et al., 2003) documented the first stage of the program, in which simulant liquids were used to characterize the buoyant plume that is produced when a jet of crude oil is injected downward into brine. This report documents the final two test series. In the first, the plume hydrodynamics experiments were completed using SPR oil, brine, and sludge. In the second, oil reinjection into brine was run for approximately 6 hours, and sampling of oil, sludge, and brine was performed over the next 3 months so that the long-term effects of oil-sludge mixing could be assessed. For both series, the experiment consisted of a large transparent vessel that is a scale model of the proposed oil-injection process at the SPR. For the plume hydrodynamics experiments, an oil layer was floated on top of a brine layer in the first test series and on top of a sludge layer residing above the brine in the second test series. The oil was injected downward through a tube into the brine at a prescribed depth below the oil-brine or sludge-brine interface. Flow rates were determined by scaling to match the ratio of buoyancy to momentum between the experiment and the SPR. Initially, the momentum of the flow produces a downward jet of oil below the tube end. Subsequently, the oil breaks up into droplets due to shear forces, buoyancy dominates the flow, and a plume of oil droplets rises to the interface. The interface was deflected upward by the impinging oil-brine plume. Videos of this flow were recorded for scaled flow rates that bracket the equivalent pumping rates in an SPR cavern during injection of degassed oil. Image-processing analyses were

  16. Ramucirumab Injection

    Science.gov (United States)

    ... dose of ramucirumab injection. Tell your doctor or nurse if you experience any of the following while you receive ramucirumab: uncontrollable shaking of a part of the body; back pain or spasms; chest pain and tightness; chills; flushing; ...

  17. Assessment of nitrification potential in ground water using short term, single-well injection experiments.

    Science.gov (United States)

    Smith, R L; Baumgartner, L K; Miller, D N; Repert, D A; Böhlke, J K

    2006-01-01

    Nitrification was measured within a sand and gravel aquifer on Cape Cod, MA, using a series of single-well injection tests. The aquifer contained a wastewater-derived contaminant plume, the core of which was anoxic and contained ammonium. The study was conducted near the downgradient end of the ammonium zone, which was characterized by inversely trending vertical gradients of oxygen (270 to 0 microM) and ammonium (19 to 625 microM) and appeared to be a potentially active zone for nitrification. The tests were conducted by injecting a tracer solution (ambient ground water + added constituents) into selected locations within the gradients using multilevel samplers. After injection, the tracers moved by natural ground water flow and were sampled with time from the injection port. Rates of nitrification were determined from changes in nitrate and nitrite concentration relative to bromide. Initial tests were conducted with (15)N-enriched ammonium; subsequent tests examined the effect of adding ammonium, nitrite, or oxygen above background concentrations and of adding difluoromethane, a nitrification inhibitor. In situ net nitrate production exceeded net nitrite production by 3- to 6- fold and production rates of both decreased in the presence of difluoromethane. Nitrification rates were 0.02-0.28 mumol (L aquifer)(-1) h(-1) with in situ oxygen concentrations and up to 0.81 mumol (L aquifer)(-1) h(-1) with non-limiting substrate concentrations. Geochemical considerations indicate that the rates derived from single-well injection tests yielded overestimates of in situ rates, possibly because the injections promoted small-scale mixing within a transport-limited reaction zone. Nonetheless, these tests were useful for characterizing ground water nitrification in situ and for comparing potential rates of activity when the tracer cloud included non-limiting ammonium and oxygen concentrations.

  18. New Experiences With Steam Injection From The MÜhlacker Field Site

    Science.gov (United States)

    Theurer, T.; Koschitzky, H.-P.; Färber, A.

    A thermally enhanced remediation scheme employing steam injection has been used at a former hazardous waste disposal site near the City of Mühlacker, Germany, to remove chlorinated solvents. Finding SVE (soil vapour extraction) to be ineffective in the unsaturated soil zone, a pilot-scale project was initiated in 1999 to employ steam injection in the highly contaminated unsaturated low permeable zone 7-15 meters be- low ground surface, limited on top and bottom by very low permeable layers. After completion of the project in September 2001, approximately 2.8 tons of chlorinated hydrocarbons had been removed from the 2500 m3 target area. This project served as a pilot site in the State of Baden-Württemberg EPA (Landesanstalt für Umweltschutz, LfU) site cleanup program, which was funded through the State's "Kommunaler Alt- lastenfonds". Detailed evaluation of SVE technology had indicated that the low permeability in this soil served as a limiting factor for "cold" SVE. As a result, alternative technologies were considered and thermally enhanced SVE by steam injection was selected in 1998 to address the unsaturated zone contaminants. A 20-meter diameter, egg-shaped test- ing area was constructed at the site for pilot-scale demonstration of the steam injection process. The testing area comprised one central injection well surrounded by six ex- traction wells that could be used simultaneously for vapor and liquid extraction. Ten monitoring lances with a total of 100 temperature sensors measured subsurface tem- peratures through the soil horizon. Using a gas-fired 100 kW generator, steam was injected at a rate of up to 100 kg/hour and a pressure of up to 2.5 bars. After ten months of steam injection, nearly complete heating of the target zone had been achieved. of the 2800 kg of TCE removed, approximately 95% was extracted in the gaseous phase and the remaining part as solute in condensed water from the capillary barrier on bottom of the soil horizon. This condensed

  19. Single well push-pull CO2 injection experiment for evaluating in-situ residual trapping at Heletz, Israel

    Science.gov (United States)

    Niemi, Auli; Bensabat, Jacob; Fagerlund, Fritjof; Ronen, Rona; Goren, Yoni; Perez, Lily; Tsarfis, Igal; Joodaki, Saba; Yang, Zhibing; Liang, Tian; Sauter, Martin; Hassan, Jawad; Gouze, Philippe; Rasmusson, Kristina

    2017-04-01

    The Heletz sands is a depleted oil reservoir at 1.6 km depth with saline water at its edges. In the saline part of the reservoir a CO2 injection experiment site has been developed for the purpose of scientifically motivated injection experiments, especially in the context of EU FP7 projects MUSTANG and TRUST. This presentation describes the single-well CO2 injection experiment carried out in September 2016, with the objective of determining field scale values of key CO2 trapping mechanisms, the residual and dissolution trapping. The sequence consisted in creating a residually trapped CO2 zone as well as reference hydraulic and heater tests prior and after the establishment of the zone, in order to determine the in-situ residual trapping. Monitoring included down-hole pressure and temperature measurement, distributed temperature sensing along the well via an optical fiber (DTS), U-tube sampling and tracers. We here present the experimental sequence, the monitoring and sampling system, the key results as well as the first interpretations.

  20. Assessment of electrical conductivity as a surrogate measurement for water samples in a tracer injection experiment

    Science.gov (United States)

    The transport behavior of solutes in streams depends on chemical, physical, biological, and hydrodynamic processes. Although it is a very complex system, it is known that this behavior is greatly influenced by surface and subsurface flows. For this reason, tracer injection in the water flows is one ...

  1. Oklahoma experiences largest earthquake during ongoing regional wastewater injection hazard mitigation efforts

    Science.gov (United States)

    Yeck, William; Hayes, Gavin; McNamara, Daniel E.; Rubinstein, Justin L.; Barnhart, William; Earle, Paul; Benz, Harley M.

    2017-01-01

    The 3 September 2016, Mw 5.8 Pawnee earthquake was the largest recorded earthquake in the state of Oklahoma. Seismic and geodetic observations of the Pawnee sequence, including precise hypocenter locations and moment tensor modeling, shows that the Pawnee earthquake occurred on a previously unknown left-lateral strike-slip basement fault that intersects the mapped right-lateral Labette fault zone. The Pawnee earthquake is part of an unprecedented increase in the earthquake rate in Oklahoma that is largely considered the result of the deep injection of waste fluids from oil and gas production. If this is, indeed, the case for the M5.8 Pawnee earthquake, then this would be the largest event to have been induced by fluid injection. Since 2015, Oklahoma has undergone wide-scale mitigation efforts primarily aimed at reducing injection volumes. Thus far in 2016, the rate of M3 and greater earthquakes has decreased as compared to 2015, while the cumulative moment—or energy released from earthquakes—has increased. This highlights the difficulty in earthquake hazard mitigation efforts given the poorly understood long-term diffusive effects of wastewater injection and their connection to seismicity.

  2. Micro Engineering: Experiments conducted on the use of polymeric materials in micro injection moulding

    DEFF Research Database (Denmark)

    Griffiths, Christian; Tosello, Guido; Nestler, Joerg

    2008-01-01

    To advance micro injection moulding it is necessary to study systematically the factors affecting process and tooling reliability. This paper reviews the main findings of Cardiff Universities 4M and SEMOFS research in this field. In particular, the factors affecting the manufacturability of micro...

  3. Road Maintenance Experience Using Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization as Ground Rehabilitation

    Science.gov (United States)

    Fakhar, A. M. M.; Asmaniza, A.

    2016-07-01

    There are many types of ground rehabilation and improvement that can be consider and implement in engineering construction works for soil improvement in order to prevent road profile deformation in later stage. However, when comes to road maintenance especially on operated expressways, not all method can be apply directly as it must comply to opreation's working window and lane closure basis. Key factors that considering ideal proposal for ground rehabilitation are time, cost, quality and most importantly practicality. It should provide long lifespan structure in order to reduce continuous cycle of maintenance. Thus, this paper will present two approaches for ground rehabilitation, namely Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization. The first approach is an injection system which consists two-parts chemical grout of Isocynate and Polyol when mixed together within soil structure through injection will polymerized with volume expansion. The strong expansion of grouting causes significant compression and compacting of the surrounding soil and subsequently improve ground properties and uplift sunken structure. The later is a cold in-place recyclying whereby mixture process that combines in-situ soil materials, cement, white powder (alkaline) additive and water to produce hard yet flexible and durable ground layer that act as solid foundation with improved bearing capacity. The improvement of the mechanical behaviour of soil through these two systems is investigated by an extensive testing programme which includes in-situ and laboratory test in determining properties such as strength, stiffness, compressibility, bearing capacity, differential settlement and etc.

  4. Electron Temperature Evolution During Local Helicity Injection on the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Barr, J. L.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Perry, J. M.; Reusch, J. A.; Rodriguez Sanchez, C.

    2016-10-01

    Understanding the electron temperature (Te) evolution during local helicity injection (LHI) is critical for scaling up this non-solenoidal startup technique to MA-class devices. The first comprehensive Te measurements during LHI reveal centrally-peaked profiles with Te > 100 eV for plasma current Ip > 120 kA, toroidal field 0.15 T, and electron density ne 1019 m-3. Te rises and is sustained from just after magnetic relaxation through the plasma decoupling from edge-localized injectors. Results are presented for two injector edge locations: outboard midplane and inboard divertor. Outboard midplane injection couples LHI with inductive drive from poloidal field ramps and radial compression during inward plasma growth. Comparisons of Te at different LHI-to-inductive drive ratios show some profile flattening for higher LHI drive fraction. The latter, constant-shape discharges were necessarily lower performance, with Ip 50 kA and reduced Te , max. Inboard divertor injection achieves higher Ip using minimal inductive drive and thus isolates effects of LHI drive on Te. Initial results in this configuration show Te rising rapidly at the injector location as the discharge grows, settling to a roughly flat profile 100 eV. Thus far, both scenarios provide relatively stable discharges with moderate ne and high-Te, suitable for coupling to auxiliary current drive. Detailed studies of confinement dynamics and discharge optimization are planned for the near future. Work supported by US DOE Grant DE-FG02-96ER54375.

  5. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Garnier, D.T.

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient ({ell}{sub p} {le} a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li{sup +} emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = {infinity} and the n = 1 marginal stability limits.

  6. TRACE code validation for BWR spray cooling injection based on GOTA facility experiments

    Energy Technology Data Exchange (ETDEWEB)

    Racca, S. [San Piero a Grado Nuclear Research Group (GRNSPG), Pisa (Italy); Kozlowski, T. [Royal Inst. of Tech., Stockholm (Sweden)

    2011-07-01

    Best estimate codes have been used in the past thirty years for the design, licensing and safety of NPP. Nevertheless, large efforts are necessary for the qualification and the assessment of such codes. The aim of this work is to study the main phenomena involved in the emergency spray cooling injection in a Swedish designed BWR. For this purpose, data from the Swedish separate effect test facility GOTA have been simulated using TRACE version 5.0 Patch 2. Furthermore, uncertainty calculations have been performed with the propagation of input errors method and the identification of the input parameters that mostly influence the peak cladding temperature has been performed. (author)

  7. Transient changes in shallow groundwater chemistry during the MSU ZERT CO2 injection experiment

    Science.gov (United States)

    Apps, J.A.; Zheng, Lingyun; Spycher, N.; Birkholzer, J.T.; Kharaka, Y.; Thordsen, J.; Kakouros, E.; Trautz, R.

    2011-01-01

    Food-grade CO2 was injected into a shallow aquifer through a perforated pipe placed horizontally 1-2 m below the water table at the Montana State University Zero Emission Research and Technology (MSU-ZERT) field site at Bozeman, Montana. The possible impact of elevated CO2 levels on groundwater quality was investigated by analyzing 80 water samples taken before, during, and following CO2 injection. Field determinations and laboratory analyses showed rapid and systematic changes in pH, alkalinity, and conductance, as well as increases in the aqueous concentrations of trace element species. The geochemical data were first evaluated using principal component analysis (PCA) in order to identify correlations between aqueous species. The PCA findings were then used in formulating a geochemical model to simulate the processes likely to be responsible for the observed increases in the concentrations of dissolved constituents. Modeling was conducted taking into account aqueous and surface complexation, cation exchange, and mineral precipitation and dissolution. Reasonable matches between measured data and model results suggest that: (1) CO2 dissolution in the groundwater causes calcite to dissolve. (2) Observed increases in the concentration of dissolved trace metals result likely from Ca+2-driven ion exchange with clays (smectites) and sorption/desorption reactions likely involving Fe (hydr)oxides. (3) Bicarbonate from CO2 dissolution appears to compete for sorption with anionic species such as HAsO4-2, potentially increasing dissolved As levels in groundwater. ?? 2011 Published by Elsevier Ltd.

  8. Suppression of Alfvén Modes on the National Spherical Torus Experiment Upgrade with Outboard Beam Injection

    Science.gov (United States)

    Fredrickson, E. D.; Belova, E. V.; Battaglia, D. J.; Bell, R. E.; Crocker, N. A.; Darrow, D. S.; Diallo, A.; Gerhardt, S. P.; Gorelenkov, N. N.; LeBlanc, B. P.; Podestà, M.; NSTX-U Team

    2017-06-01

    In this Letter we present data from experiments on the National Spherical Torus Experiment Upgrade, where it is shown for the first time that small amounts of high pitch-angle beam ions can strongly suppress the counterpropagating global Alfvén eigenmodes (GAE). GAE have been implicated in the redistribution of fast ions and modification of the electron power balance in previous experiments on NSTX. The ability to predict the stability of Alfvén modes, and developing methods to control them, is important for fusion reactors like the International Tokamak Experimental Reactor, which are heated by a large population of nonthermal, super-Alfvénic ions consisting of fusion generated α 's and beam ions injected for current profile control. We present a qualitative interpretation of these observations using an analytic model of the Doppler-shifted ion-cyclotron resonance drive responsible for GAE instability which has an important dependence on k⊥ρL . A quantitative analysis of this data with the hym stability code predicts both the frequencies and instability of the GAE prior to, and suppression of the GAE after the injection of high pitch-angle beam ions.

  9. Experience of direct percutaneous sac injection in type II endoleak using cone beam computed tomography.

    Science.gov (United States)

    Park, Yoong-Seok; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Dong-Ik

    2015-04-01

    Cone beam CT, usually used in dental area, could easily obtain 3-dimensional images using cone beam shaped ionized radiation. Cone beam CT is very useful for direct percutaneous sac injection (DPSI) which needs very precise measurement to avoid puncture of inferior vena cava or vessel around sac or stent graft. Here we describe two cases of DPSI using cone beam CT. In case 1, a 79-year-old male had widening of preexisted type II endoleak after endovascular aneurysm repair (EVAR). However, transarterial embolization failed due to tortuous collateral branches of lumbar arteries. In case 2, a 72-year-old female had symptomatic sac enlargement by type II endoleak after EVAR. However, there was no route to approach the lumbar arteries. Therefore, we performed DPSI assisted by cone beam CT in cases 1, 2. Six-month CT follow-up revealed no sign of sac enlargement by type II endoleak.

  10. EXPERIENCE OF INTRAVENOUS INJECTION OF NORMAL HUMAN IMMUNOGLOBULIN IN A PATIENT WITH KAWASAKI SYNDROME

    Directory of Open Access Journals (Sweden)

    T. V. Sleptsova

    2014-01-01

    Full Text Available The article presents a case of late diagnosis of cutaneomucosal lymphonodular syndrome (Kawasaki syndrome. The child featured fever, mucosal lesion (conjunctivitis, stomatitis, rash, thick edemas on arms and feet, arthritis and coronaritis. Initial therapy proved ineffective. Pathogenetic therapy, which proved to be rather effective, was prescribed after diagnosis was confirmed. The authors present a case of successful use of normal human immunoglobulin for intravenous injections in the dose of 2 g/kg of body weight per course in combination with acetylsalicylic acid in the dose of 80 mg/kg per day. Body temperature decreased down to subfebrile figures and foot pain attenuated as early as after 1 day of treatment. Fever, rash, stomatitis and conjunctivitis terminated, edemas of limbs and arthritic manifestations attenuated considerably and laboratory parameters of disease activity normalized after 1 week (ESR and CRP. Inflammation of coronary arteries terminated after 3 weeks. No adverse events in the setting of immunoglobulin therapy were observed.  

  11. Initial Thomson Scattering Survey of Local Helicity Injection and Ohmic Plasmas at the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Winz, G. R.

    2014-10-01

    A multipoint Thomson scattering diagnostic has recently been installed on the Pegasus ST. The system utilizes a frequency-doubled Nd:YAG laser (λ0 ~ 532 nm), spectrometers with volume phase holographic gratings, and a gated, intensified CCD camera. It provides measurements of Te and ne at 8 spatial locations for each spectrometer once per discharge. A new multiple aperture and beam dump system has been implemented to mitigate interference from stray light. This system has provided initial measurements in the core region of plasmas initiated by local helicity injection (LHI), as well as conventional Ohmic L- and H-mode discharges. Multi-shot averages of low-density (ne ~ 3 ×1018 m-3) , Ip ~ 0 . 1 MA LHI discharges show central Te ~ 75 eV at the end of the helicity injection phase. Ip ~ 0 . 13 MA Ohmic plasmas at moderate densities (ne ~ 2 ×1019 m-3) have core Te ~ 150 eV in L-mode. Generally, these plasmas do not reach transport equilibrium in the short 25 ms pulse length available. After an L-H transition, strong spectral broadening indicates increasing Te, to values above the range of the present spectrometer system with a high-dispersion VPH grating. Near-term system upgrades will focus on deploying a second spectrometer, with a lower-dispersion grating capable of measuring the 0.1-1.0 keV range. The second spectrometer system will also increase the available number of spatial channels, enabling study of H-mode pedestal structure. Work supported by US DOE Grant DE-FG02-96ER54375.

  12. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  13. Geophysical monitoring of near surface CO2 injection at Svelvik - Learnings from the CO2FieldLab experiments.

    Science.gov (United States)

    Querendez, Etor; Romdhane, Anouar; Jordan, Michael; Eliasson, Peder; Grimstad, Alv-Arne

    2014-05-01

    A CO2 migration field laboratory for testing monitoring methods and tools has been established in the glaciofluvial-glaciomarine Holocene deposits of the Svelvik ridge, near Oslo (Norway). At the site, feasibility, sensitivity, acquisition geometry and usefulness of various surface and subsurface monitoring tools are investigated during controlled CO2 injection experiments. In a first stage, a shallow CO2 injection experiment was conducted in September 2011. Approximately 1700 kg of CO2 was injected at 18 m depth below surface in an unconsolidated sand formation. The objectives of this experiment were to (i) detect and, where possible, quantify migrated CO2 concentrations at the surface and very shallow subsurface, (ii) evaluate the sensitivity of the monitoring tools and (iii) study the impact of the vadose zone on observed measurements. Results showed that all deployed monitoring tools (for surface and near-surface gas monitoring, subsurface water monitoring and subsurface geophysical monitoring) where able to detect the presence of CO2 even though the CO2 plume did not migrate vertically as expected in what was thought to be an homogeneous unconsolidated sand structure. The upper part of the site revealed to be more heterogeneous than expected, mainly due to the highly variable lamination and channelling of the morainic sediments and to the presence of pebble and cobble beds sporadically showing throughout the deposits. Building on the learnings from the 18m depth injection experiment, a second experiment is being planned for a deeper injection, at a depth of 65m. Re-processing of the appraisal 2D multi-channel seismic with state-of-the-art processing techniques, like Linear Radon coherent and random noise attenuation and Full Waveform Inversion followed by pre-stack depth migration, corroborate the presence of heterogeneities at the near surface. Based on the re-interpreted seismic sections, a more realistic 3D geomodel, where the complex topography of the site

  14. Preferential heating of light ions during an ionospheric Ar(+) injection experiment

    Science.gov (United States)

    Pollock, C. J.; Chandler, M. O.; Moore, T. E.; Arnoldy, R. L.; Kintner, P. M.; Chesney, S.; Cahill, L. J., Jr.

    1995-01-01

    The Argon Release for Controlled Studies (ARCS) 4 sounding rocket was launched northward into high altitude from Poker Flat Research Range on February 23, 1990. The vehicle crossed geomagnetic field lines containing discrete auroral activity. An instrumented subpayload released 100-eV and 200-eV Ar(+) ion beams sequentially, in a direction largely perpendicular to both the local geomagnetic field and the subpayload spin axis. The instrumented main payload was separated along field lines from the beam emitting subpayload by a distance which increased at a steady rate of approximately 2.4 m/s. Three dimensional mass spectrometric ion observations of ambient H(+) and O(+) ions, obtained on board the main payload, are presented. Main payload electric field observations in the frequency range 0-16 kHz, are also presented. These observations are presented to demonstrate the operation of transverse ion acceleration, which was differential with respect to ion mass, primarily during 100-eV beam operations. The preferential transverse acceleration of ambient H(+) ions, as compared with ambient O(+) ions, during the second, third, fourth, and fifth 100-eV beam operations, is attributed to a resonance among the injected Ar(+) ions, beam-generated lower hybrid waves, and H(+) ions in the tail of the ambient thermal distribution. This work provides experimental support of processes predicted by previously published theory and simulations.

  15. Design of a shock-induced combustion experiment in an axisymmetric configuration with hydrogen injection

    NARCIS (Netherlands)

    Verreault, J.; DeChamplain, A.; Mayer, A.E.H.J.; Veraar, R.G.; Stowe, R.A.; Farinaccio, R.; Harris, P.G.

    2007-01-01

    This work presents a design for a shock-induced combustion experiment using a two-angle cone configuration. Three injector geometries were considered: a cone surface, a dual stage configuration with rectangular gaps (DSRG) and a cylindrical ramp (CR). Four parameters were investigated: the

  16. Design of a shock-induced combustion experiment in an axisymmetric configuration with hydrogen injection

    NARCIS (Netherlands)

    Verreault, J.; DeChamplain, A.; Mayer, A.E.H.J.; Veraar, R.G.; Stowe, R.A.; Farinaccio, R.; Harris, P.G.

    2007-01-01

    This work presents a design for a shock-induced combustion experiment using a two-angle cone configuration. Three injector geometries were considered: a cone surface, a dual stage configuration with rectangular gaps (DSRG) and a cylindrical ramp (CR). Four parameters were investigated: the penetrati

  17. Fluorouracil Injection

    Science.gov (United States)

    ... of a doctor who is experienced in giving chemotherapy medications for cancer. Treatment with fluorouracil injection may cause serious side effects. ... this medication.If you experience a serious side effect, you or your doctor ... (FDA) MedWatch Adverse Event Reporting program online (http://www.fda.gov/ ...

  18. Paliperidone Injection

    Science.gov (United States)

    ... the body slow movements or shuffling walk painful erection of the penis that lasts for hours cough, chills and/or other signs of infection Paliperidone injection may cause other side effects. Call your doctor if you have any unusual problems while taking this medication.If you experience a ...

  19. Ziprasidone Injection

    Science.gov (United States)

    ... stiffness falling confusion sweating loss of consciousness painful erection of the penis that lasts for hours Ziprasidone injection may cause other side effects. Call your doctor if you have any unusual problems while receiving this medication.If you experience a ...

  20. Risperidone Injection

    Science.gov (United States)

    ... control slow movements or shuffling walk falling painful erection of the penis that lasts for hours Risperidone extended-release injection may cause other side effects. Call your doctor if you have any unusual problems while receiving this medication.If you experience a ...

  1. MREIT experiments with 200μA injected currents: a feasibility study using two reconstruction algorithms, SMM and Harmonic BZ

    Science.gov (United States)

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as the IEC601. This protocol limits patient auxiliary currents to 100μA for low frequencies. However, published MREIT studies have utilized currents 10 to 400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200μA total injected current and we tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul in 1998 with Tikhonov regularization and the Harmonic BZ proposed by Oh et al in 2003. The reconstruction techniques were tested at both 200μA and 5mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200μA total injected current into a cylindrical phantom generates only 14.7μA current in imaging slice. Similarly, 5mA total injected current results in 367μA in imaging slice. Total acquisition time for 200μA and 5mA experiments were about one

  2. Demonstration of Tokamak ohmic flux saving by transient coaxial helicity injection in the national spherical torus experiment.

    Science.gov (United States)

    Raman, R; Mueller, D; Nelson, B A; Jarboe, T R; Gerhardt, S; Kugel, H W; Leblanc, B; Maingi, R; Menard, J; Ono, M; Paul, S; Roquemore, L; Sabbagh, S; Soukhanovskii, V

    2010-03-05

    Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

  3. Charge-injection-device performance in the high-energy-neutron environment of laser-fusion experiments.

    Science.gov (United States)

    Marshall, F J; DeHaas, T; Glebov, V Yu

    2010-10-01

    Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester's OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (∼10(14) DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick-Baez microscopes. The neutron fluences ranged from ∼10(7) to ∼10(9) neutrons/cm(2) and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ∼10(15), depending on distance and shielding.

  4. The External-Injection experiment at the SPARC{sub L}AB facility

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Andrea R., E-mail: andrea.rossi@mi.infn.it [INFN - MI, via Celoria 16, 20133 Milan (Italy); Bacci, Alberto [INFN - MI, via Celoria 16, 20133 Milan (Italy); Belleveglia, Marco; Chiadroni, Enrica [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Cianchi, Alessandro [“Tor Vergata” University, Physics Department, via della Ricerca Scientifica 1, 00133 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Di Pirro, Giampiero; Ferrario, Massimo; Gallo, Alessandro; Gatti, Giancarlo [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Maroli, Cesare [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); Mostacci, Andrea [“La Sapienza” University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Petrillo, Vittoria [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); INFN - MI, via Celoria 16, 20133 Milan (Italy); Serafini, Luca [INFN - MI, via Celoria 16, 20133 Milan (Italy); Tomassini, Paolo [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); Vaccarezza, Cristina [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy)

    2014-03-11

    At the SPARC{sub L}AB facility of INFN-LNF we are installing a transport lines for ultra-short electron bunches and another for ultra-intense laser pulses, generated by the SPARC photo-injector and by the FLAME laser in a synchronized fashion at the tens of fs level, to co-propagate inside a hydrogen filled glass capillary, in order to perform acceleration of the electron bunch by a plasma wave driven by the laser pulse. The main aim of this experiment is to demonstrate that a high brightness electron beam can be accelerated by a plasma wave without any significant degradation of its quality. Motivations of the technical choices are made and expected performances are reported.

  5. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China.

    Science.gov (United States)

    Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.

  6. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People’s Republic of China

    Science.gov (United States)

    Zhu, Ling-ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People’s Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. PMID:24669192

  7. Multilevel Botulinum Toxin A (Abobotulinum Toxin A Injections in Spastic Forms of Cerebral Palsy: Retrospective Analysis of 8 Russian Centers Experience

    Directory of Open Access Journals (Sweden)

    O. A. Klochkova

    2016-01-01

    Full Text Available Background: The contemporary application of Botulinum toxin A (BTA in cerebral palsy (CP implies multilevel injections both in on-label and off-label muscles. However, there is no single international opinion on the effective and safe dosages, target muscles, and intervals between the injections.Objective: Our aim was to analyze the Russian multicenter independent experience of single and repeated multilevel injections of Abobotulinum toxin А in patients with spastic forms of CP.Methods: 8 independent referral CP-centers (10 hospitals in different regions of Russia. Authors evaluated intervals between the injections, dosages of the BTA for the whole procedure, for the body mass, for the each muscle, and functional segment of the extremities.Results: 1872 protocols of effective BTA injections (1–14 repeated injections for 724 patients with spastic CP were included. The age of the patients was between 8 months to 17 years 4 months at the beginning of the treatment (with a mean of 3 years 10 months. Multilevel BTA injections were indicated for the majority (n = 634, 87.6% of the patients in all the centers. The medians of the dosages for the first BTA injection were between 30–31 U/kg (500 U, the repeated injections doses up to 45 U/kg (1000 U (in most centers. The median intervals between the repeated injections were 180–200 days in 484 (66.9% patients and 140–180 days in 157 (24.7% patients. In 2 centers, children with GMFCS IV–V were injected more often than others.Conclusion: Multilevel BTA injections were indicated for the most patients. The initial dose of Abobotulinum toxin A was 30–31 U/kg. The repeated injections dose could increase up to 40 U/kg. The repeated injections were done in 140–200 days after the previous injection.

  8. Extended Magnetohydrodynamic Simulations of the Helicity Injected Torus (HIT-SI) Spheromak Experiment with the NIMROD Code

    Science.gov (United States)

    Akcay, Cihan

    A comparative study of 3-D pressureless resistive (single-fluid) magnetohydrodynamic (rMHD) and 3-D pressureless two-fluid magnetohydrodynamic (2fl-MHD) models of the Helicity Injected Torus experiment (HIT-SI) is presented. HIT-SI is a spheromak current-drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The goal of the experiment is to demonstrate that steady inductive helicity injection (SIHI) is a viable method for driving and sustaining a magnetized plasma for the eventual purpose of electricity production with magnetic fusion power. The experiment has achieved sustainment of nearly 100 kA of plasma current for ˜1~ms. Fusion power plants are expected to sustain a burning plasma for many minutes to hours with more than 10~MA of plasma current. The purpose of project is to determine the validity of the single-fluid and two-fluid MHD models of HIT-SI. The comparable size of the collisionless ion skin depth to the diameter of the injectors and resistive skin depth predicates the importance of two-fluid effects. The simulations are run with NIMROD (non-ideal magnetohydrodynamics code with rotation-open discussion), an initial-value, 3-D extended MHD code. A constant and uniform plasma density and temperature are assumed. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification and formation time

  9. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China

    Directory of Open Access Journals (Sweden)

    Zhu LL

    2014-03-01

    Full Text Available Ling-ling Zhu,1 Wei Li,2 Ping Song,3 Quan Zhou3 1Geriatric VIP Ward, Division of Nursing, 2Division of Medical Administration, 3Department of Pharmacy, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China Abstract: The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1 improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2 complications associated with vascular access; 3 incidents induced by absence of efficient electronic pump management and infusion tube management; and 4 liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. Keywords

  10. 挤压铸造设备压射运动参数的实验研究%Experiment Research for Injection Movement Parameters of Squeeze Casting Equipment

    Institute of Scientific and Technical Information of China (English)

    宋雷; 邵明

    2014-01-01

    Injection is one of key function of squeeze casting equipment, movement parameters vitally effect the quality of castings. Through experiment research for injection movement parameters, obvious fluctuation of injection velocity is found, the analysis for cause of velocity fluctuation is carried out, and improved suggestion is proposed.%压射功能是挤压铸造设备的核心功能之一,压射过程的运动参数是对铸件的质量有着重要的影响。通过对压射运动参数进行实验研究,发现压射速度存在明显的波动,并对造成压射速度波动的主要原因进行分析,提出了改进建议。

  11. “We don’t need services. We have no problems”: exploring the experiences of young people who inject drugs in accessing harm reduction services

    Directory of Open Access Journals (Sweden)

    Anita Krug

    2015-02-01

    Full Text Available Introduction: Evidence suggests that people who inject drugs often begin their drug use and injecting practices in adolescence, yet there are limited data available on the HIV epidemic and the responses for this population. The comprehensive package of interventions for the prevention, treatment and care of HIV infection among people who inject drugs first laid out in 2009 (revised in 2012 by World Health Organization, United Nations Office of Drugs and Crime and Joint United Nations Programme on HIV/AIDS, does not consider the unique needs of adolescent and young people. In order to better understand the values and preferences of young people who inject drugs in accessing harm reduction services and support, we undertook a series of community consultations with young people with experience of injecting drugs during adolescence. Methods: Community consultations (4–14 persons were held in 14 countries. Participants were recruited using a combined criterion and maximum variation sampling strategy. Data were analyzed using collaborative qualitative data analysis. Frequency analysis of themes was conducted. Results: Nineteen community consultations were organized with a total of 132 participants. All participants had experienced injecting drugs before the age of 18. They had the following age distribution: 18–20 (37%, 21–25 (48% and 26–30 (15%. Of the participants, 73.5% were male while 25.7% were female, with one transgender participant. Barriers to accessing the comprehensive package included: lack of information and knowledge of services, age restrictions on services, belief that services were not needed, fear of law enforcement, fear of stigma, lack of concern, high cost, lack of outreach, lack of knowledge of HCV/TB and lack of youth friendly services. Conclusions: The consultations provide a rare insight into the lived experiences of adolescents who inject drugs and highlight the dissonance between their reality and current policy and

  12. Subcutaneous injection of thallium-201 chloride and gallium-67 citrate at acupuncture point K-3; An animal experiment and human-being study

    Energy Technology Data Exchange (ETDEWEB)

    Johg, Shiang-Bin; Wu, Chung-Chieng; Chen, Ming-Feng; Wu, Sheng-Nan (Kaohsiung Medical Coll., Taiwan (China))

    1992-09-01

    Subcutaneous (SC) injection of [sup 99m]Tc pertechnetate ([sup 99m]Tc) at acupuncture points K-3 is a new method of lower-limb radionuclide venography. To investigate the mechanism of absorption of [sup 99m]Tc from SC injected sites into vascular system, various radioisotopes such as [sup 201]Tl chloride ([sup 201]Tl) and [sup 67]Ga citrate ([sup 67]Ga) were SC injected at K-3 points in animal and human-beings experiments. It was found that [sup 99m]Tc and [sup 201]Tl were absorbed rapidly from K-3 points through venous system and into whole body soft tissue. However, [sup 67]Ga with a larger effective ionic radius than [sup 201]Tl was not absorbed throughout the observation of 5 minutes. Furthermore, intravenous administration of digitalis, a Na[sup +]-K[sup +] pump blocker, did not inhibit the absorption of [sup 99m]Tc and [sup 201]Tl after SC injection at K-3 points. These results suggest that absorption of radionuclides on SC injection at K-3 points is mainly through the passive pathway of diffusion rather than the active transport, and the effective ionic radius may be a major factor influencing the absorption rate of the radionuclides. (author).

  13. Effects of intra-prelimbic prefrontal cortex injection of cannabidiol on anxiety-like behavior: involvement of 5HT1A receptors and previous stressful experience.

    Science.gov (United States)

    Fogaça, M V; Reis, F M C V; Campos, A C; Guimarães, F S

    2014-03-01

    The prelimbic medial prefrontal cortex (PL) is an important encephalic structure involved in the expression of emotional states. In a previous study, intra-PL injection of cannabidiol (CBD), a major non-psychotomimetic cannabinoid present in the Cannabis sativa plant, reduced the expression of fear conditioning response. Although its mechanism remains unclear, CBD can facilitate 5HT1A receptor-mediated neurotransmission when injected into several brain structures. This study was aimed at verifying if intra-PL CBD could also induce anxiolytic-like effect in a conceptually distinct animal model, the elevated plus maze (EPM). We also verified if CBD effects in the EPM and contextual fear conditioning test (CFC) depend on 5HT1A receptors and previous stressful experience. CBD induced opposite effects in the CFC and EPM, being anxiolytic and anxiogenic, respectively. Both responses were prevented by WAY100,635, a 5HT1A receptor antagonist. In animals that had been previously (24h) submitted to a stressful event (2h-restraint) CBD caused an anxiolytic, rather than anxiogenic, effect in the EPM. This anxiolytic response was abolished by previous injection of metyrapone, a glucocorticoid synthesis blocker. Moreover, restraint stress increased 5HT1A receptors expression in the dorsal raphe nucleus, an effect that was attenuated by injection of metyrapone before the restraint procedure. Taken together, these results suggest that CBD modulation of anxiety in the PL depend on 5HT1A-mediated neurotransmission and previous stressful experience.

  14. Medroxyprogesterone Injection

    Science.gov (United States)

    Medroxyprogesterone intramuscular (into a muscle) injection and medroxyprogesterone subcutaneous (under the skin) injection are used to prevent pregnancy. Medroxyprogesterone subcutaneous injection is also used to treat endometriosis (a condition in which ...

  15. Pentamidine Injection

    Science.gov (United States)

    Pentamidine injection is used to treat pneumonia caused by a fungus called Pneumocystis carinii. It is in ... Pentamidine injection comes as powder to be mixed with liquid to be injected intramuscularly (into a muscle) ...

  16. Dynamic investigation of nutrient consumption and injection strategy in microbial enhanced oil recovery (MEOR) by means of large-scale experiments.

    Science.gov (United States)

    Song, Zhiyong; Zhu, Weiyao; Sun, Gangzheng; Blanckaert, Koen

    2015-08-01

    Microbial enhanced oil recovery (MEOR) depends on the in situ microbial activity to release trapped oil in reservoirs. In practice, undesired consumption is a universal phenomenon but cannot be observed effectively in small-scale physical simulations due to the scale effect. The present paper investigates the dynamics of oil recovery, biomass and nutrient consumption in a series of flooding experiments in a dedicated large-scale sand-pack column. First, control experiments of nutrient transportation with and without microbial consumption were conducted, which characterized the nutrient loss during transportation. Then, a standard microbial flooding experiment was performed recovering additional oil (4.9 % Original Oil in Place, OOIP), during which microbial activity mostly occurred upstream, where oil saturation declined earlier and steeper than downstream in the column. Subsequently, more oil remained downstream due to nutrient shortage. Finally, further research was conducted to enhance the ultimate recovery by optimizing the injection strategy. An extra 3.5 % OOIP was recovered when the nutrients were injected in the middle of the column, and another additional 11.9 % OOIP were recovered by altering the timing of nutrient injection.

  17. Assessment of RELAP5/MOD3.1 for gravity-driven injection experiment in the core makeup tank of the CARR Passive Reactor (CP-1300)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.I.; No, H.C. [Korea Advanced Inst. of Science and Technology, Yusung, Taejon (Korea, Republic of). Nuclear Engineering Dept.; Bang, Y.S.; Kim, H.J. [Korea Inst. of Nuclear Safety, Yusung Taejon (Korea, Republic of). Advanced Reactor Dept.

    1996-10-01

    The objective of the present work is to improve the analysis capability of RELAP5/MOD3.1 on the direct contact condensation in the core makeup tank (CMT) of passive high-pressure injection system (PHPIS) in the CARR Passive Reactor (CP-1300). The gravity-driven injection experiment is conducted by using a small scale test facility to identify the parameters having significant effects on the gravity-driven injection and the major condensation modes. It turns out that the larger the water subcooling is, the more initiation of injection is delayed, and the sparger and the natural circulation of the hot water from the steam generator accelerate the gravity-driven injection. The condensation modes are divided into three modes: sonic jet, subsonic jet, and steam cavity. RELAP5/MOD3.1 is chosen to evaluate the cod predictability on the direct contact condensation in the CMT. It is found that the predictions of MOD3.1 are in better agreement with the experimental data than those of MOD3.0. From the nodalization study of the test section, the 1-node model shows better agreement with the experimental data than the multi-node models. RELAP5/MOD3.1 identifies the flow regime of the test section as vertical stratification. However, the flow regime observed in the experiment is the subsonic jet with the bubble having the vertical cone shape. To accurately predict the direct contact condensation in the CMT with RELAP5/MOD3.1, it is essential that a new set of the interfacial heat transfer coefficients and a new flow regime map for direct contact condensation in the CMT be developed.

  18. Perspectives and experiences of Dutch multiple sclerosis patients and multiple sclerosis-specialized neurologists on injectable disease-modifying treatment

    NARCIS (Netherlands)

    Visser, Leo H.; Heerings, Marco A.; Jongen, Peter J.; van der Hiele, Karin

    2016-01-01

    Background: The adherence to treatment with injectable disease-modifying drugs (DMDs) in multiple sclerosis (MS) may benefit from adequate information provision and management of expectations. The communication between patients and physicians is very important in this respect. The current study inve

  19. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  20. Laboratory experiments simulating poroelastic stress changes associated with depletion and injection in low-porosity sedimentary rocks

    Science.gov (United States)

    Ma, Xiaodong; Zoback, Mark D.

    2017-04-01

    We characterized the poroelastic deformation of six cores from three formations associated with the Bakken play in the Williston Basin (the Lodgepole, Middle Bakken, and Three Forks formations). All are low-porosity, low-permeability formations, but vary considerably in clay, kerogen, and carbonate content. The experimental program simulated reservoir stress changes associated with depletion and injection via cycling both the confining pressure (Pc) and pore pressure (Pp). We measured volumetric strain, derived the corresponding bulk modulus, and calculated the Biot coefficient (α). We found α, which generally ranges between 0.3 and 0.9, to vary systematically with Pc and Pp for each of the specimens tested. The effect of pore pressure on α is much larger at low simple effective stress (σ = Pc-Pp) during depletion than injection. The α decreases with σ for all pore pressures. For the same Pc and Pp, the Biot coefficient is consistently higher during injection than during depletion. Given the observed variations of α with Pc and Pp, the modeling of reservoir stress changes using a constant α could be problematic as poroelastic stress changes during depletion and injection are not likely to follow the same path. Scanning electron microscope examination of microstructures suggests that the variations of the bulk modulus and the Biot coefficient can be attributed to the abundance of compliant components (pores, microcracks, clays, and organic matter) and how they are distributed throughout the rock matrix.

  1. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  2. Preventing Sciatic Nerve Injury due to Intramuscular Injection: Ten-Year Single-Center Experience and Literature Review.

    Science.gov (United States)

    Geyik, Sirma; Geyik, Murat; Yigiter, Remzi; Kuzudisli, Samiye; Saglam, Sadullah; Elci, Mehmet Ali; Yilmaz, Mustafa

    2017-01-01

    Sciatic nerve injury is the most frequent and serious complication of intramuscular gluteal injection. This study aims to highlight the incidence and causes of this continuing problem and to discuss the relevant literature. problems is relatively rare. We suggest a double quadrant drawing technique in each gluteal region. We also draw attention to this issue with postgraduate and in-service training programs of medical staff, and providing continuity in education can reduce this serious complication.

  3. Intratumor photosensitizer injection for photodynamic therapy: Pre-clinical experience with methylene blue, Pc 4, and Photofrin

    Science.gov (United States)

    Baran, Timothy M.; Foster, Thomas H.

    2016-03-01

    Intravenous administration of some photosensitizers, including the FDA-approved Photofrin, results in significant systemic photosensitivity and a 2-3-day drug-light interval. Direct intratumor injection of photosensitizer could potentially eliminate these negative aspects of photodynamic therapy (PDT), while requiring a lower photosensitizer dose to achieve comparable drug concentration in the target tissue. We performed PDT using intratumor injection of 3 photosensitizers, methylene blue (MB), Pc 4, and Photofrin, in mouse tumor models. After a 0-15 minute drug-light interval, illumination was delivered by appropriate diode lasers. For animals receiving MB or Pc 4, surface illumination was delivered using a microlens-terminated fiber. For animals receiving Photofrin, interstitial illumination was delivered by a 1 cm diffuser. In animals receiving MB or Pc 4, tumor dimensions were measured daily post-PDT, with a cure being defined as no palpable tumor 90 days post-treatment. For Photofrin, animals were sacrificed 24 hours post-PDT and tumors were excised, with samples HE stained to assess PDT-induced necrosis. 55% of tumors were cured with MB-PDT, and significant tumor growth delay (p=0.002) was observed for Pc 4. For Photofrin PDT, the mean necrosis radius was 3.4+/-0.8 mm, compared to 2.9+/-1.3 mm for systemic administration, which was not a significant difference (p=0.58). Intratumoral injection of the photosensitizers methylene blue, Pc 4, and Photofrin is feasible, and results in appreciable tumor response. Further investigation is necessary to optimize treatment protocols and assess the systemic photosensitivity induced by intratumor injection.

  4. Simulation of injector dynamics during steady inductive helicity injection current drive in the HIT-SI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C., E-mail: hansec@uw.edu [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Columbia University, New York, New York 10027 (United States); Marklin, G. [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Victor, B. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); Akcay, C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Jarboe, T. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); PSI-Center, University of Washington, Seattle, Washington 98195 (United States)

    2015-04-15

    We present simulations of inductive helicity injection in the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) device that treats the entire plasma volume in a single dynamic MHD model. A new fully 3D numerical tool, the PSI-center TETrahedral mesh code, was developed that provides the geometric flexibility required for this investigation. Implementation of a zero-β Hall MHD model using PSI-TET will be presented including formulation of a new self-consistent magnetic boundary condition for the wall of the HIT-SI device. Results from simulations of HIT-SI are presented focusing on injector dynamics that are investigated numerically for the first time. Asymmetries in the plasma loading between the two helicity injectors and progression of field reversal in each injector are observed. Analysis indicates cross-coupling between injectors through confinement volume structures. Injector impedance is found to scale with toroidal current at fixed density, consistent with experimental observation. Comparison to experimental data with an injector drive frequency of 14.5 kHz shows good agreement with magnetic diagnostics. Global mode structures from Bi-Orthogonal decomposition agree well with experimental data for the first four modes.

  5. Managing la malilla: Exploring drug treatment experiences among injection drug users in Tijuana, Mexico, and their implications for drug law reform.

    Science.gov (United States)

    Syvertsen, Jennifer; Pollini, Robin A; Lozada, Remedios; Vera, Alicia; Rangel, Gudelia; Strathdee, Steffanie A

    2010-11-01

    In August 2009, Mexico reformed its drug laws and decriminalized small quantities of drugs for personal use; offenders caught three times will be mandated to enter drug treatment. However, little is known about the quality or effectiveness of drug treatment programs in Mexico. We examined injection drug users' (IDUs) experiences in drug treatment in Tijuana, Mexico, with the goal of informing program planning and policy. We examined qualitative and quantitative data from Proyecto El Cuete, a multi-phased research study on HIV risk among IDUs in Tijuana. Phase I consisted of 20 in-depth interviews and Phase II employed respondent-driven sampling to recruit 222 IDUs for a quantitative survey. We also reviewed national drug policy documents, surveillance data, and media reports to situate drug users' experiences within the broader sociopolitical context. Participants in the qualitative study were 50% male with a mean age of 32; most injected heroin (85.0%) and methamphetamine (60.0%). The quantitative sample was 91.4% male with a mean age of 35; 98.2% injected heroin and 83.7% injected heroin and methamphetamine together. The majority of participants reported receiving treatment: residential treatment was most common, followed by methadone; other types of services were infrequently reported. Participants' perceptions of program acceptability and effectiveness were mixed. Mistreatment emerged as a theme in the qualitative interviews and was reported by 21.6% of Phase II participants, primarily physical (72.0%) and verbal (52.0%) abuse. Our results point to the need for political, economic, and social investment in the drug treatment system before offenders are sentenced to treatment under the revised national drug law. Resources are needed to strengthen program quality and ensure accountability. The public health impact of the new legislation that attempts to bring drug treatment to the forefront of national drug policy should be systematically evaluated. Copyright

  6. Doripenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such ... if you are allergic to doripenem injection; other carbapenem antibiotics such as imipenem/cilastatin (Primaxin) or meropenem ( ...

  7. Methotrexate Injection

    Science.gov (United States)

    Methotrexate injection is used alone or in combination with other medications to treat gestational trophoblastic tumors (a ... in bones) after surgery to remove the tumor. Methotrexate injection is also used to treat severe psoriasis ( ...

  8. Bendamustine Injection

    Science.gov (United States)

    Bendamustine injection is used to treat chronic lymphocytic leukemia (CLL; a type of cancer of the white ... injection. You should use birth control to prevent pregnancy in yourself or your partner during your treatment ...

  9. Caspofungin Injection

    Science.gov (United States)

    Caspofungin injection is used in adults and children 3 months of age and older to treat yeast ... people with a weakened ability to fight infection. Caspofungin injection is in a class of antifungal medications ...

  10. Temozolomide Injection

    Science.gov (United States)

    Temozolomide is used to treat certain types of brain tumors. Temozolomide is in a class of medications called alkylating ... Temozolomide injection comes as a powder to be added to fluid and injected over 90 minutes intravenously ( ...

  11. Pembrolizumab Injection

    Science.gov (United States)

    Pembrolizumab injection is used to treat melanoma (a type of skin cancer) that cannot be treated with ... who have a specific type of melanoma tumor. Pembrolizumab injection is also used to treat a certain ...

  12. Lacosamide Injection

    Science.gov (United States)

    ... injection is in a class of medications called anticonvulsants. It works by decreasing abnormal electrical activity in ... older (about 1 in 500 people) who took anticonvulsants like lacosamide injection to treat various conditions during ...

  13. Midazolam Injection

    Science.gov (United States)

    ... injection is in a class of medications called benzodiazepines. It works by slowing activity in the brain ... breast-feeding.talk to your doctor about the risks and benefits of receiving midazolam injection if you ...

  14. Doxycycline Injection

    Science.gov (United States)

    Doxycycline injection is used to treat or prevent bacterial infections, including pneumonia and other respiratory tract infections. ... certain skin, genital, intestine, and urinary system infections. Doxycycline injection may be used to treat or prevent ...

  15. Paclitaxel Injection

    Science.gov (United States)

    ... with other medications. Paclitaxel injection manufactured with polyoxyethylated castor oil is used to treat ovarian cancer (cancer that ... cancer, and lung cancer. Paclitaxel injection with polyoxyethylated castor oil is also used to treat Kaposi's sarcoma (a ...

  16. Etanercept Injection

    Science.gov (United States)

    ... will be using the prefilled syringe or automatic injection device, tell your doctor if you or the person who will be injecting the medication for you are allergic to rubber or latex.tell your doctor and pharmacist what ...

  17. Cyclosporine Injection

    Science.gov (United States)

    Cyclosporine injection is used with other medications to prevent transplant rejection (attack of the transplanted organ by ... who have received kidney, liver, and heart transplants. Cyclosporine injection should only be used to treat people ...

  18. Estrogen Injection

    Science.gov (United States)

    The estradiol cypionate and estradiol valerate forms of estrogen injection are used to treat hot flushes (hot ... should consider a different treatment. These forms of estrogen injection are also sometimes used to treat the ...

  19. Cefotaxime Injection

    Science.gov (United States)

    Cefotaxime injection is used to treat certain infections caused by bacteria including pneumonia and other lower respiratory ... skin, blood, bone, joint, and urinary tract infections. Cefotaxime injection may also be used before surgery, and ...

  20. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  1. Experiment data report for Semiscale Mod-1 tests S-05-2A and S-05-2B (alternate ECC injection tests)

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Jr., M. L.; Collins, B. L.; Sackett, K. E.

    1977-04-01

    Recorded test data are presented for Tests S-05-2A and S-05-2B of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Tests S-05-2A and S-05-2B were conducted from initial conditions of 2263 psia and 543/sup 0/F and 2272 psia and 542/sup 0/F, respectively, to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the tests, cooling water was injected into the intact loop pump suction and broken loop cold leg to simulate emergency core coolant injection in a PWR with flow rates based on system volume scaling. For Test S-05-2A the intact loop pump speed was held constant throughout the test at the initial blowdown value. During Test S-05-2B the pump speed was reduced and stopped according to a predetermined coastdown schedule.

  2. Ustekinumab Injection

    Science.gov (United States)

    ... Do not inject into an area where the skin is tender, bruised, red, or hard or where you have scars or stretch marks.Your doctor or pharmacist will ... injection.you should know that ustekinumab injection may decrease your ability ... new or changing skin lesions, minor infections (such as open cuts or ...

  3. Ranitidine Injection

    Science.gov (United States)

    Ranitidine injection comes as a solution (liquid) to be mixed with another fluid and injected intravenously (into a vein) over 5 to 20 minutes. Ranitidine may also be injected into a muscle. It is usually given every 6 to 8 hours, but may also be given ...

  4. Experience in using injectable valproic acid (convulex in patients with serial epileptic seizures and status epilepticus at the prehospital stage

    Directory of Open Access Journals (Sweden)

    A. V. Lebedeva

    2012-01-01

    Full Text Available Objective: to evaluate the efficacy of injectable valproate (convulex in patients with serial epileptic seizures and status epilepticus (SE at the prehospital stage.Patients and methods. Thirty-two adult patients, including 17 (53% men and 15 (47% women, were examined. Most patients were aged over 40 years (mean age 54.7±9.4 years. To define the required dose of the drug, the authors estimated the patient's weight that averaged 76.8±1.9 kg, i.e. there was a preponderance of patients who needed convulex, more than 500 mg, to achieve a therapeutic effect.Results. It was impossible to reliably and validly evaluate the type of a seizure as the medical emergency team (MET generally observed the patient with a just evolving seizure and the medical history data were not always valid therefore the type of convulsions and the type of a seizure were evaluated. In most cases, solitary convulsive attacks (tonic and/or clonic convulsions and/or serial seizures were observed in 12 (37.5% and 14 (43.7% patients, respectively; SE was recorded in 6 (8.8% patients. Generalized seizures (without a clear focal onset were prevalent in 24 (75% patients while 8 (25% patients were found to have partial seizures (seizure onset lateralization, a focal onset. According to the pattern of convulsions, seizures may be classified into three types: tonic-clonic, clonic, and tonic in 22 (68.8%, 7 (21.9%, and 3 (9.3% patients, respectively. Analysis of the efficacy of intravenously injectable valproate (convulex in the group of patients with SE and epileptic seizures indicated that complete cessation of seizures could be achieved in 68.8%, their rate decreased in other 9.4% of the patients. Seizures were preserved in 7 (21.8% cases, which required additional administration of drugs. Conclusion. Injectable valproic acid (convulex has a high efficacy and may be preclinically used as the drug of choice to arrest SE and serial seizures caused by both epilepsy and other

  5. Prevalence and characteristics of abuse experiences and depression symptoms among injection drug-using female sex workers in Mexico.

    Science.gov (United States)

    Ulibarri, Monica D; Hiller, Sarah P; Lozada, Remedios; Rangel, M Gudelia; Stockman, Jamila K; Silverman, Jay G; Ojeda, Victoria D

    2013-01-01

    This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors-ever experiencing forced sex and forced sex in the context of sex work-were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  6. Prevalence and Characteristics of Abuse Experiences and Depression Symptoms among Injection Drug-Using Female Sex Workers in Mexico

    Directory of Open Access Journals (Sweden)

    Monica D. Ulibarri

    2013-01-01

    Full Text Available This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors—ever experiencing forced sex and forced sex in the context of sex work—were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  7. Trace Code Validation for BWR Spray Cooling Injection and CCFL Condition Based on GÖTA Facility Experiments

    Directory of Open Access Journals (Sweden)

    Stefano Racca

    2012-01-01

    Full Text Available Best estimate codes have been used in the past thirty years for the design, licensing, and safety of NPP. Nevertheless, large efforts are necessary for the qualification and the assessment of such codes. The aim of this work is to study the main phenomena involved in the emergency spray cooling injection in a Swedish-designed BWR. For this purpose, data from the Swedish separate effect test facility GÖTA have been simulated using TRACE version 5.0 Patch 2. Furthermore, uncertainty calculations have been performed with the propagation of input errors method, and the identification of the input parameters that mostly influence the peak cladding temperature has been performed.

  8. [Animal experiment studies on the effect of intra-articular injections of antiphlogistic-antirheumatic agents on articular cartilage in vivo].

    Science.gov (United States)

    Kalbhen, D A; Schauer, M; Wentsche, B

    1978-01-01

    Animal experiments have shown that weekly intraarticular injections of various antiphlogistic/antirheumatic drugs into the knee joint induce progressive degenerative alterations in joint cartilage. The observed degenerations and destructions are most similar to the pathophysiology of osteoarthrosis in humans. By X-ray and macroscopic techniques the degenerative processes can be studied qualitatively and quantitatively. A decrease of joint space is a sensitive and early indicator of osteoarthrosis and showed that 10 weeks after intraarticular application of Ibuprofen, Phenylbutazone, Oxyphenbutazone, Flufenamic acid, Niflumic acid, Na-salicylate, Clofezone, Bumadizone and Dexamethasone the degenerative alterations in the injected knee joints were more severe than by applications of Chloroquine,D-penicillamine, Salicylamide and Indometacin. The degenerative effect on articular cartilage by the investigated drugs can be explained by their inhibitory potency on anabolic metabolism of connective tissue. The results of our animal experiments lead to the conclusion, that antiinflammatory drugs may also in man induce or accelerate degenerative joint diseases especially after long term treatment with high doses of these drugs.

  9. Analysis of system thermal hydraulic responses for passive safety injection experiment at ROSA-IV Large Scale Test Facility. Using JAERI modified version of RELAP5/MOD2 code

    Energy Technology Data Exchange (ETDEWEB)

    Asaka, Hideaki; Yonomoto, Taisuke; Kukita, Yutaka (Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment)

    1994-12-01

    An experiment was conducted at the ROSA-IV/Large Scale Test Facility (LSTF) on the performance of a gravity-driven emergency core coolant (ECC) injection system attached to a pressurized water reactor (PWR). Such a gravity-driven injection system, though not used in the current-generation PWRs, is proposed for future reactor designs. The experiment was performed to identify key phenomena peculiar to the operation of a gravity injection system and to provide data base for code assessment against such phenomena. The simulated injection system consisted of a tank which was initially filled with cold water of the same pressure as the primary system. The tank was connected at its top and bottom, respectively, to the cold leg and the vessel downcomer. The injection into the downcomer was driven primarily by the static head difference between the cold water in the tank and the hot water in the pressure balance line (PBL) connecting the cold leg to the tank top. The injection flow was oscillatory after the flow through the PBL became two-phase flow. The experiment was post-test analyzed using a JAERI modified version of the RELAP5/MOD2 code. The code calculation simulated reasonably well the system responses observed in the experiment, and suggested that the oscillations in the injection flow was caused by oscillatory liquid holdup in the PBL connecting the cold leg to tank top. (author).

  10. Effects of intra-infralimbic prefrontal cortex injections of cannabidiol in the modulation of emotional behaviors in rats: contribution of 5HT₁A receptors and stressful experiences.

    Science.gov (United States)

    Marinho, A L Z; Vila-Verde, C; Fogaça, M V; Guimarães, F S

    2015-06-01

    The infralimbic (IL) and prelimbic (PL) regions of the prefrontal cortex are involved in behavioral responses observed during defensive reactions. Intra-PL or IL injections of cannabidiol (CBD), a major non-psychotomimetic cannabinoid present in the Cannabis sativa plant, result in opposite behavioral effects in the contextual fear conditioning (CFC) paradigm. The intra-PL effects of CBD are mediated by 5HT1A receptors and depend on previous stressful experiences but the mechanisms and effects of intra-IL CBD injected are unknown. To this aim the present work verified the effects of intra-IL administration of CBD on two animal models of anxiety, the elevated plus maze (EPM) and CFC. We also investigated if these effects were mediated by 5HT1A receptors and depended on previous stressful experience. Male Wistar rats received bilateral microinjections of vehicle, WAY100635 (5HT1A receptor antagonist, 0.37 nmol) and/or CBD (15, 30 or 60 nmol) before being submitted to the behavioral tests. Intra-IL CBD induced anxiolytic and anxiogenic in the EPM and CFC, respectively. To verify if these effects are influenced by the previous stressful experience (footshocks) in the CFC model, we tested the animals in the EPM 24h after a 2-h restraint period. The anxiolytic-like effect of CBD in the EPM disappeared when the animals were previously stressed. Both responses, i.e., anxiolytic and anxiogenic, were prevented by WAY100635, indicating that they involve local 5HT1A-mediated neurotransmission. Together these results indicate that CBD effects in the IL depend on the nature of the animal model, being influenced by previous stressful experiences and mediated by facilitation of 5HT1A receptors-mediated neurotransmission.

  11. Direct injection method for HPLC/MS/MS analysis of acrylamide in aqueous solutions: application to adsorption experiments.

    Science.gov (United States)

    Mnif, Ines; Hurel, Charlotte; Marmier, Nicolas

    2015-05-01

    Polyacrylamides are polymers used in many fields and represent the main source of release of the highly toxic acrylamide in the environment. In this work, a simple, rapid, and sensitive analytical method was developed with HPLC/MS/MS and direct injection for acrylamide analysis in water and adsorption samples. AFNOR standards NF T90-210 and NF T90-220 were used for the analytical method validation and uncertainty estimation. Limit of quantification (LOQ) for acrylamide was 1 μg/L, and accuracy was checked at three acrylamide levels (1, 6, and 10 μg/L). Uncertainties were estimated at 34.2, 22, and 12.4 % for acrylamide concentrations at LOQ, 6 μg/L, and 10 μg/L, respectively. Acrylamide adsorption on clays (kaolinite, illite) and sludge was then studied as a function of pH, time, and acrylamide concentrations. Acrylamide adsorption on kaolinite, illite, and sludge was found to be very weak since adsorption percentages were inferior to 10 %, whatever the pH value and the initial acrylamide concentration. The low affinity of acrylamide for clays and sludge is likely due to its hydrophilic property, small size, and charge neutrality.

  12. No Immunogenicity of IPS Cells in Syngeneic Host Studied by In Vivo Injection and 3D Scaffold Experiments

    Directory of Open Access Journals (Sweden)

    Suganya Thanasegaran

    2013-01-01

    Full Text Available Induced Pluripotent Stem Cells (IPSCs open the great possibility to employ patient’s own tissue to the previously incurable diseases. However these cells can be used in cell therapy only if they are not rejected when transplanted back into the syngeneic host. We found that the injection of iPSCs derived from different ages of mice into syngeneic C57BL/6 mice produced teratoma and was not rejected. Then we cultured iPSCs and myeloid differentiated iPSCs in three-dimensional porous scaffold and transplanted to C57BL/6 mice and BALB/C mice. After transplantation, we could observe the cell density inside the scaffold increased rapidly in syngeneic mice compared to the allogeneic mice indicating the favorable conditions supporting the growth of iPSCs in vivo. Unlike the allogeneic counterpart, we could not observe few infiltrating T cells inside the scaffold of syngeneic mice. These results contribute to the optimistic view of iPSCs for regenerative medicine in near future.

  13. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure...... build-up was evaluated indirectly from the changes in the flow rate between subcutaneous injections and air injections. This method enabled the tissue counter pressure to be evaluated without a formal clinical study approval. The measurements were coupled to a model for the pressure evolution...

  14. A qualitative study of experiences with and perceptions regarding long-acting injectable antipsychotics: Part I-patient perspectives.

    Science.gov (United States)

    Iyer, Srividya; Banks, Nicola; Roy, Marc-André; Tibbo, Phil; Williams, Richard; Manchanda, Rahul; Chue, Pierre; Malla, Ashok

    2013-05-01

    Objectif : Malgré le problème largement reconnu de la mauvaise observance des antipsychotiques (AP), les injectables à action prolongée (IAP) qui pourraient améliorer l’observance sont sous-utilisés au Canada. Les attitudes à l’égard des IAP chez les patients et les psychiatres peuvent contribuer à cette sous-utilisation. Notre objectif était d’enquêter sur les perceptions et les attitudes des patients à l’égard des IAP au Canada. Méthode : Des groupes de discussion ont été formés de 34 patients ayant reçu un diagnostic de psychose du spectre de la schizophrénie dans 4 provinces canadiennes. Les groupes de discussion portaient sur les expériences avec les AP IAP et les attitudes à leur égard. Les séances ont fait l’objet d’un enregistrement sonore et ont été transcrites textuellement, et ces transcriptions ont été codées à l’aide d’une combinaison de méthodes déductives et inductives. Résultats : Quatre thèmes se sont dégagés : conscience et connaissance des IAP; perceptions des IAP; considérations concernant le coût et la commodité; et les questions liées au contexte coercitif dans lequel les IAP sont souvent prescrits. Neuf patients n’avaient jamais entendu parler des IAP, et d’autres ont déclaré ne pas avoir compris lorsqu’on a discuté avec eux des IAP. Les patients avaient habituellement entendu parler des IAP dans un contexte soit de coercition, soit de non-observance des médicaments. Les patients avaient des perceptions positives et négatives à l’égard des IAP. Les perceptions positives étaient axées sur la prévention de la rechute et l’effort réduit pour maintenir l’observance, et les perceptions négatives portaient sur les coûts financiers et la complication des rendez-vous pour recevoir les injections. Conclusion : Afin d’accroître l’utilisation des IAP, il faut aborder certaines questions, notamment l’insuffisance de l’information donnée aux patients, l

  15. Low mortality but increasing incidence of Staphylococcus aureus endocarditis in people who inject drugs: Experience from a Swedish referral hospital.

    Science.gov (United States)

    Asgeirsson, Hilmir; Thalme, Anders; Weiland, Ola

    2016-12-01

    Staphylococcus aureus is a leading cause of infective endocarditis in people who inject drugs (PWID). The management of S aureus endocarditis (SAE) in PWID can be problematic. The objective of this retrospective observational study was to assess the epidemiology, clinical characteristics, and mortality of S aureus endocarditis (SAE) in PWID in Stockholm, Sweden.The Department of Infectious Diseases at the Karolinska University Hospital serves as a regional referral center for drug users with severe infections. Patients with active intravenous drug use treated for SAE at the department between January 2004 and December 2013 were retrospectively identified. Clinical and microbiological data were obtained from medical records and the diagnosis verified according to the modified Duke criteria.In total, 120 SAE episodes related to intravenous drug use were identified. Its incidence in Stockholm was 0.76/100,000 adult person-years for the entire period, increasing from 0.52/100,000 person-years in 2004 to 2008 to 0.99 in 2009 to 2013 (P = 0.02). The SAE incidence among PWID specifically was 249 (range 153-649) /100,000 person-years. Forty-two (35%) episodes were left-sided, and multiple valves were involved in 26 (22%). Cardiac valve surgery was performed in 10 (8%) episodes, all left-sided. The in-hospital and 1-year mortality rates were 2.5% (3 deaths) and 8.0% (9 deaths), respectively.We noted a high and increasing incidence over time of SAE related to intravenous drug use in Stockholm. The increased incidence partly reflects a rising number of PWID during the study period. The low mortality noted, despite a substantial proportion with left-sided endocarditis, probably in part reflects the quality of care obtained at a large and specialized referral center for drug users with severe infections.

  16. Light scattering experiments on aqueous solutions of selected cellulose ethers: contribution to the study of polymer-mineral interactions in a new injectable biomaterial

    Science.gov (United States)

    Bohic, Sylvain; Weiss, Pierre; Roger, Philippe; Daculsi, Guy

    2001-01-01

    Hydroxypropylmethylcellulose (HPMC) is used as a ligand for a bioactive calcium phosphate ceramic (the filler) in a ready-to-use injectable sterilized biomaterial for bone and dental surgery. Light scattering experiments were usually used to study high water-soluble polymers and to determine the basic macromolecular parameters. In order to gain a deeper understanding of polymer/mineral interactions in this type of material, we have investigated the effect of divalent and trivalent ions (Ca2+, PO43−) and steam sterilization on dilute solutions of HPMC and HEC. The sterilization process may cause some degradation of HEC taking into account its high molecular weight and some rigidity of the polymer chain. Moreover, in the case of HPMC, the changes in the conformations rather than degradation process are supposed. These effects of degradation and flocculation are strengthened in alkaline medium. Experimental data suggested the formation of chelate complexes between Ca2+ and HPMC which improve its affinity to the mineral blend and consolidate the injectable biomaterial even in the case of its hydration by biological fluid. PMID:15348303

  17. Design Experience and Skills of Large Injection Mold%大型注塑模具设计经验与技巧

    Institute of Scientific and Technical Information of China (English)

    张维合

    2012-01-01

    Design experience and skills of large injection mold were introduced by using the refrigerator transparent store content ark injection mould as an example. The hydraulic cylinder for lateral oblique core-pulling, the fission style inclined top for inside-oblique core pulling, the pressure gas and push block for plastic parts demolding were adopted. Its side core-pulling mechanism was complex, and cooling system design was reasonable. Production practice proved that the forming period and plastic parts quality could meet the requirements of customer.%以某电冰箱透明储物柜注塑模具为例,简述了大型注塑模具的设计经验与技巧.模具采用液压油缸进行外侧斜向抽芯,采用分体式斜顶进行内侧斜向抽芯,采用气压和推块联合推出塑件.模具侧向抽芯机构复杂,冷却系统设计合理.实际运行表明,成型周期和塑件质量符合客户要求.

  18. Injection MD

    CERN Document Server

    Bartmann, W; Bracco, C; Drosdal, L; Gianfelice, E; Goddard, B; Kain, V; Papaphilippou, Y; Vanbavinckhove, G

    2012-01-01

    This note summarizes the results obtained at injection during the 2nd MD block and the floating MD block in July. Highlights are presented for injection in the LHC with the Q20 SPS optics, influence of the supercycle and injection with 25 ns bunch spacing. Beams were successfully injected into the LHC using the Q20 optics [1, 3]. Small corrections were needed to steer the beam in the transfer lines. Dispersion measurements were conducted for both beams. The horizontal normalized dispersion in TI2 was a factor 2 smaller for Q20 with respect to Q26, for TI8 on the other hand the opposite was observed. The results for injection loss dependency on super cycle composition show only a small increase in losses for beam 2. The losses observed must therefore mainly come from other sources such as shot-by-shot stability or quality of scraping. For the injection with 25 ns bunch spacing bunches were injected for both beams. For B1 up to the maximum of 288 bunches. For B2 on the other only up to 144 bunches were injected...

  19. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure...... build-up was evaluated indirectly from the changes in the flow rate between subcutaneous injections and air injections. This method enabled the tissue counter pressure to be evaluated without a formal clinical study approval. The measurements were coupled to a model for the pressure evolution...... in subcutaneous tissue, based on mass conservation and flow in a porous medium. From the measurements the flow permeability and bulk modulus of the tissue were determined. In the adipose tissue the drug forms a bolus from where it is absorbed by the blood capillaries. The spatial distribution of the injected...

  20. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

    Science.gov (United States)

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-07-07

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10-400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215-25) with Tikhonov regularization and the harmonic B(Z) proposed by Oh et al (2003 Magn. Reason. Med. 50 875-8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total

  1. Mepolizumab Injection

    Science.gov (United States)

    ... or do not go away: pain, redness, swelling, warmth, burning, or itching in the place mepolizumab was injected headache dry and itchy skin with or without red, scaly rashes back pain muscle spasms Some side ...

  2. Metoclopramide Injection

    Science.gov (United States)

    ... and feeling of fullness that lasts long after meals. Metoclopramide injection is also used to prevent nausea ... tranylcypromine (Parnate); narcotic medications for pain; sedatives; sleeping pills; tetracycline (Bristacycline, Sumycin); tranquilizers. Your doctor may need ...

  3. Alemtuzumab Injection

    Science.gov (United States)

    Alemtuzumab injection is used to treat B-cell chronic lymphocytic leukemia (a slowly developing cancer in which ... of white blood cell accumulate in the body). Alemtuzumab is in a class of medications called monoclonal ...

  4. Ferumoxytol Injection

    Science.gov (United States)

    Ferumoxytol injection is used to treat iron-deficiency anemia (a lower than normal number of red blood ... pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking or ...

  5. Fludarabine Injection

    Science.gov (United States)

    Fludarabine injection is used to treat chronic lymphocytic leukemia (CLL; a type of cancer of the white ... a reliable method of birth control to prevent pregnancy during this time. Talk to your doctor for ...

  6. Insulin Injection

    Science.gov (United States)

    ... or buttocks. Do not inject insulin into muscles, scars, or moles. Use a different site for each ... you are using insulin.Alcohol may cause a decrease in blood sugar. Ask your doctor about the ...

  7. Tigecycline Injection

    Science.gov (United States)

    ... in a person who was not in the hospital), skin infections, and infections of the abdomen (area between the ... that developed in people who were in a hospital or foot infections in people who have diabetes. Tigecycline injection is ...

  8. Golimumab Injection

    Science.gov (United States)

    Golimumab injection is used alone or with other medications to relieve the symptoms of certain autoimmune disorders ( ... did not help or could not be tolerated. Golimumab is in a class of medications called tumor ...

  9. Albiglutide Injection

    Science.gov (United States)

    ... will develop tumors of the thyroid gland, including medullary thyroid carcinoma (MTC; a type of thyroid cancer). ... symptoms or those listed in the IMPORTANT WARNING section, stop using albiglutide injection and call your doctor ...

  10. Dexamethasone Injection

    Science.gov (United States)

    ... body tissues,) gastrointestinal disease, and certain types of arthritis. Dexamethasone injection is also used for diagnostic testing. ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  11. Hydrocortisone Injection

    Science.gov (United States)

    ... own organs), gastrointestinal disease, and certain types of arthritis. Hydrocortisone injection is also used to treat certain ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  12. Methylprednisolone Injection

    Science.gov (United States)

    ... own organs), gastrointestinal disease, and certain types of arthritis. Methylprednisolone injection is also used to treat certain ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  13. Glatiramer Injection

    Science.gov (United States)

    ... To inject glatiramer, follow these steps: Remove one blister pack from the carton of glatiramer syringes and place ... paper label and remove the syringe from the blister pack. Check your prefilled syringe to be sure it ...

  14. Dexrazoxane Injection

    Science.gov (United States)

    ... that are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are ...

  15. Evolocumab Injection

    Science.gov (United States)

    ... autoinjector in hot water, microwave, or place in sunlight.Before you use evolocumab injection, look at the ... chills pain or burning during urination muscle or back pain dizziness stomach pain Some side effects can be ...

  16. Cidofovir Injection

    Science.gov (United States)

    Cidofovir injection is used along with another medication (probenecid) to treat cytomegaloviral retinitis (CMV retinitis) in people with acquired immunodeficiency syndrome (AIDS). Cidofovir is in a class of medications called antivirals. ...

  17. Brivaracetam Injection

    Science.gov (United States)

    ... older. Brivaracetam in a class of medications called anticonvulsants. It works by decreasing abnormal electrical activity in ... older (about 1 in 500 people) who took anticonvulsants like brivaracetam injection to treat various conditions during ...

  18. Diphenhydramine Injection

    Science.gov (United States)

    ... not to use diphenhydramine injection if you are breastfeeding because of the risk of harm to infants.tell your doctor if you have or have ever had asthma or other types of lung disease; glaucoma (a ...

  19. Cefazolin Injection

    Science.gov (United States)

    ... valve, respiratory tract (including pneumonia), biliary tract, and urinary tract infections. Cefazolin injection also may be used before, during, ... to learn about take-back programs in your community. See the FDA's Safe Disposal of Medicines website ( ...

  20. Ceftazidime Injection

    Science.gov (United States)

    ... skin, blood, bone, joint, female genital tract, and urinary tract infections. Ceftazidime injection is in a class of medications ... to learn about take-back programs in your community. See the FDA's Safe Disposal of Medicines website ( ...

  1. Fluconazole Injection

    Science.gov (United States)

    ... and fungal infections of the eye, prostate (a male reproductive organ), skin and nails. Fluconazole injection is ... Motrin, others) and naproxen (Aleve, Anaprox, Naprelan); oral contraceptives (birth control pills); oral medication for diabetes such ...

  2. Moxifloxacin Injection

    Science.gov (United States)

    ... available.Moxifloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing the bacteria that cause ... you are allergic to moxifloxacin, other quinolone or fluoroquinolone antibiotics such as ciprofloxacin (Cipro), gatifloxacin (Tequin) (not available ...

  3. Levofloxacin Injection

    Science.gov (United States)

    ... available. Levofloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing bacteria that cause infections. ... severe reaction to levofloxacin; any other quinolone or fluoroquinolone antibiotic such as ciprofloxacin (Cipro), gatifloxacin (Tequin) (not available ...

  4. Ciprofloxacin Injection

    Science.gov (United States)

    ... available. Ciprofloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing bacteria that cause infections. ... reaction to ciprofloxacin or any other quinolone or fluoroquinolone antibiotic such as gatifloxacin (Tequin) (not available in the ...

  5. Alirocumab Injection

    Science.gov (United States)

    ... further decrease the amount of low-density lipoprotein (LDL) cholesterol ('bad cholesterol') in the blood. Alirocumab injection is ... antibodies. It works by blocking the production of LDL cholesterol in the body to decrease the amount of ...

  6. Chloramphenicol Injection

    Science.gov (United States)

    ... an arm or leg sudden changes in vision pain with eye movement Chloramphenicol injection may cause a condition called gray syndrome in premature and newborn infants. There have also been reports of gray ...

  7. Non-double-couple mechanisms of microearthquakes induced during the 2000 injection experiment at the KTB site, Germany: A result of tensile faulting or anisotropy of a rock?

    Science.gov (United States)

    Vavryčuk, Václav; Bohnhoff, Marco; Jechumtálová, Zuzana; Kolář, Petr; Šílený, Jan

    2008-08-01

    Moment tensors of microearthquakes induced during the 2000 injection experiment at the KTB deep drilling borehole at a depth level of 5.4 km are studied. A family of 37 most reliable moment tensors contains significant non-double-couple (non-DC) components. The DC is on average 60% and the non-DC is 40%. Fault plane solutions computed from the DC part show preferred strike-slip mechanisms with small normal or reverse components. A predominant azimuth of P and T axes is in the range of N320°-340°E and of N230°-250°E, respectively. The non-DC components contain both the isotropic (ISO) and compensated linear vector dipole (CLVD) components. The mean value of ISO is 1.5%, the mean value of CLVD is - 5.7%. The predominantly negative CLVD components are inconsistent with the concept of the non-DC mechanisms as a result of tensile faulting due to fluid injection into the rock. The main origin of the non-DC components is probably anisotropy in the focal area. The other origins are errors produced by mismodelling of the medium when calculating the Green functions, and numerical errors produced by noise and limitations of input data. Adopting four alternative models of anisotropy obtained by other seismic measurements at the KTB, we have employed the non-DC components for estimating an optimum orientation of anisotropy in the focal area. The optimum orientation of the symmetry plane of anisotropy is nearly vertical with a strike of N335°-340°E. This strike coincides well with the strike of 330° typical for many major lithological units and faults and with the orientation of the transversely isotropic model inferred by other authors. After removing the anisotropy effects from the moment tensors by calculating the source tensors, the distribution of ISO is significantly narrowed. This indicates predominantly shear, but not tensile faulting.

  8. Model experiment on change of seismic properties of a fracture caused by injecting/draining water; Chusui/haisui ni yoru kison kiretsu no dansei denpa tokusei no henka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T.; Koizumi, T.; Sassa, K. [Kyoto University, Kyoto (Japan). Faculty of Engineering

    1997-05-27

    Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water level, the waveform changes again as the level changes. The change in waveform is not so remarkable, however, as that observed during water injection thanks to the water residual in the cracks. It is now inferred that crack investigation is more effective when it is carried out with water being injected into dry cracks. The difference produced between the dry state and wet state when water is injected into dry cracks is used to detect the presence of cracks in this experiment, and this may be applied also to the investigation of cracks in the shallow part of the ground. 4 refs., 11 figs.

  9. Sarilumab Injection

    Science.gov (United States)

    ... the needle. Do not try to warm the medication by heating it in a microwave, placing it in warm water or in direct sunlight, or through any other method.Before injecting, check the prefilled syringe to be sure that the expiration date printed on the package has not passed. Look ...

  10. Enfuvirtide Injection

    Science.gov (United States)

    ... inject enfuvirtide into any skin that has a tattoo, scar, bruise, mole, a burn site, or has ... Enfuvirtide may cause side effects. Tell your doctor if any of these symptoms are severe or do not go away: itching, swelling, pain, tingling, discomfort, ...

  11. Lanreotide Injection

    Science.gov (United States)

    Lanreotide injection is used to treat people with acromegaly (condition in which the body produces too much growth hormone, causing enlargement of the hands, feet, and facial features; joint pain; and other symptoms) who have not successfully, or cannot be treated ...

  12. Subcutaneous (SQ) injections

    Science.gov (United States)

    SQ injections; Sub-Q injections; Diabetes subcutaneous injection; Insulin subcutaneous injection ... NIH. Giving a subcutaneous injection . Rockville, MD. National ... of Health and Human Services NIH publications; 2015. Available ...

  13. Experiments on current-driven three-dimensional ion sound turbulence. I - Return-current limited electron beam injection. II - Wave dynamics

    Science.gov (United States)

    Stenzel, R. L.

    1978-01-01

    Pulsed electron beam injection into a weakly collisional magnetized background plasma is investigated experimentally; properties of the electron beam and background plasma, as well as the low-frequency instabilities and wave dynamics, are discussed. The current of the injected beam closes via a field-aligned return current of background electrons. Through study of the frequency and wavenumber distribution, together with the electron distribution function, the low-frequency instabilities associated with the pulsed injection are identified as ion acoustic waves driven unstable by the return current. The frequency cut-off of the instabilities predicted from renormalized plasma turbulence theory, has been verified experimentally.

  14. Avelumab Injection

    Science.gov (United States)

    ... experience certain side effects. Tell your doctor or nurse immediately if you experience any of the following symptoms during the infusion: chills or shaking, hives, fever, flushing, back pain, shortness of breath, wheezing, or stomach pain.Your ...

  15. Initial clinical experience with near-infrared spectroscopy in assessing cerebral tissue oxygen saturation in cerebral vasospasm before and after intra-arterial verapamil injection.

    Science.gov (United States)

    Meng, Lingzhong; Settecase, Fabio; Xiao, Jifang; Yu, Zhaoxia; Flexman, Alana M; Higashida, Randall T

    2016-04-01

    Cerebral vasospasm is a devastating complication after subarachnoid hemorrhage. The use of cerebral tissue oxygen saturation (SctO2) to non-invasively assess changes in cerebral tissue perfusion induced by intra-arterial (IA) verapamil treatment has not been described to our knowledge. A total of 21 consecutive post-craniotomy patients scheduled for possible IA verapamil treatment of cerebral vasospasm were recruited. The effect of IA verapamil injection on SctO2 being continuously monitored on both the left and right forehead was investigated. Comparisons between changes in SctO2 monitored on the ipsilateral and contralateral forehead in relationship to the side of internal carotid artery (ICA) injection were performed. A total of 47 IA verapamil injections (15 left ICA, 18 right ICA, and 14 vertebral artery injections) during 18 neurointerventional procedures in 13 patients were analyzed. IA verapamil administration led to both increases and decreases in SctO2. Changes in SctO2 ipsilateral to the ICA injection side were more pronounced (p=0.02 and 0.07 for left and right ICA injections, respectively) and favored compared to contralateral SctO2 changes. We were unable to obtain reliable measurements on the side ipsilateral to the craniotomy during four procedures in three patients, presumably secondary to pneumocephalus. The local cerebral vasodilating effect of IA verapamil injection is suggested by the differential changes in SctO2 ipsilateral and contralateral to the ICA injection side. The inconsistent changes in SctO2 and the limitations of applying cerebral oximetry in this patient population needs to be recognized.

  16. Observation of abrupt changes associated with air injection into the ground by the time lapse experiment using an ultra-stable seismic source

    Science.gov (United States)

    Kasahara, J.; Ito, S.; Fujiwara, T.; Hasada, Y.; Tsuruga, K.; Ikuta, R.; Fujii, N.; Yamaoka, K.; Nishigami, K.; Ito, K.

    2011-12-01

    To prove the temporal change of seismic waves due to the injection of air into the ground, we carried out a field test near the Nojima Earthquake Fault in Awaji Island using an ultra-stable and conscious seismic source and a seismic array. The newly built seismic ACROSS was installed horizontally as the rotational axis of weight-mass was horizontal. We used 10-35Hz. We injected 80 tons air into the Okasa formation at 100 m depth. We analyzed 31 3-component seismometer records and one 3-component borehole seismometer record at 800m depth. Applying source signature deoconvolution to the filed records, we obtained the transfer function between the source and each receiver. All transfer function associated with injection revealed very large changes of waveforms immediately after the beginning of injection of air at some sites. However the station #7 at 100m from the injection well showed extremely large change at 1 day after the injection. The delay times for appearance of waveform change vary place to place and the differential waveform characteristics for each station are quite different one by one. We explain possible causes of waveform change.

  17. Experiences of PEMEX in CO{sub 2} re-injection; Experiencias de Pemex en reinyeccion de CO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Bujanos, Jose Luis [PEMEX (Mexico)

    2008-07-15

    Mexico enters the processes of secondary oil recovery the years 50s, by means of water injection. The CO{sub 2} injection is one of the techniques that better results produce in the oil recovery. In this presentation the strategic goals that have been determined within PEMEX Exploracion y Produccion (PEP) are mentioned, and which are the projects of CO{sub 2} injection for oil recovery already existing in Mexico. [Spanish] Mexico entra a los procesos de recuperacion secundaria de petroleo en los anos 50s, mediante inyeccion de agua. La inyeccion de CO{sub 2} es una de las tecnicas que mejores resultados produce en la recuperacion de petroleo. En esta presentacion se mencionan las metas estrategicas que se han fijado dentro de Pemex Exploracion y Produccion (PEP) y cuales son los proyectos de inyeccion de CO{sub 2} para recuperacion de petroleo, existentes actualmente en Mexico.

  18. The influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II - Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...... large discrepancies exist for the pad with an injection pocket. It is argued that this is likely to be due to the unevenness of the collar surface. The measured and theoretical values of oil film thickness compare well at low loads. At high loads discrepancies grow to up to 25 %. It is argued...

  19. Olanzapine Injection

    Science.gov (United States)

    ... of bed slowly, resting your feet on the floor for a few minutes before standing up.you should know that you may experience hyperglycemia (increases in your blood sugar) while you are taking this medication, even ...

  20. Zidovudine Injection

    Science.gov (United States)

    ... severe side effects, such as liver damage, blood toxicities, and muscle disorders. If you experience any of ... prescription and nonprescription medications you are taking, especially acetaminophen, acyclovir (Zovirax), aspirin, cancer chemotherapy, cimetidine (Tagamet), fluconazole ( ...

  1. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings - Part II: Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2007-01-01

    and approx. 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading-edge taper. The measurements are compared to theoretical values obtained using a three-dimensional thermoelastohydrodynamic (TEHD) numerical model...

  2. The influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II - Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...

  3. Performance Experiment of the Thermal Insulation Structure of Steam Injec-tion Boiler%注汽锅炉绝热结构性能实验

    Institute of Scientific and Technical Information of China (English)

    吴永宁; 周英; 赵海谦

    2016-01-01

    良好的绝热结构是注汽锅炉降低热能损失的前提.针对现有注汽锅炉绝热效果不理想的问题,对两种不同绝热敷设方式注汽锅炉的绝热效果进行现场检测,并对绝热材料性能进行室内实验研究.结果表明:随着使用时间延长,注汽锅炉绝热结构的绝热效果大幅度下降,折叠敷设方式稳定性优于平铺敷设方式;注汽锅炉绝热结构宜采用折叠敷设方式,且可将厚度适当压缩以提高强度.%Ideal thermal insulation structure is the key to ensuring the steam parameters of steam injection boiler and reducing heat loss.According to the present problems of steam in-jection boiler thermal insulation, insulation performance of steam injection boilers with dif-ferent thermal insulation construction method was tested on the spot, and the performances of thermal insulation material were researched. The results showed that insulation perfor-mance of steam injection boilers decreased sharply. Stability of folding laying method was better than tiling laying method.The folding laying method was suit for steam injection boiler. In order to enhancing the intension,the thickness should be compressed properly.

  4. Furosemide Injection

    Science.gov (United States)

    ... se mide)Furosemide can cause dehydration and electrolyte imbalance. If you experience any of the following symptoms, call your doctor immediately: decreased urination; dry mouth; thirst; nausea; vomiting; weakness; drowsiness; confusion; muscle pain or cramps; or rapid or pounding heartbeats.

  5. Mesna Injection

    Science.gov (United States)

    ... works by protecting against some of the harmful effects of certain chemotherapy medications. ... this medication.If you experience a serious side effect, you or your doctor may send a report to the Food and Drug Administration's (FDA) MedWatch Adverse Event Reporting program online (http://www.fda.gov/ ...

  6. Reduction of plasma density in the Helicity Injected Torus with Steady Inductance experiment by using a helicon pre-ionization source.

    Science.gov (United States)

    Hossack, Aaron C; Firman, Taylor; Jarboe, Thomas R; Prager, James R; Victor, Brian S; Wrobel, Jonathan S; Ziemba, Timothy

    2013-10-01

    A helicon based pre-ionization source has been developed and installed on the Helicity Injected Torus with Steady Inductance (HIT-SI) spheromak. The source initiates plasma breakdown by injecting impurity-free, unmagnetized plasma into the HIT-SI confinement volume. Typical helium spheromaks have electron density reduced from (2-3) × 10(19) m(-3) to 1 × 10(19) m(-3). Deuterium spheromak formation is possible with density as low as 2 × 10(18) m(-3). The source also enables HIT-SI to be operated with only one helicity injector at injector frequencies above 14.5 kHz. A theory explaining the physical mechanism driving the reduction of breakdown density is presented.

  7. Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: initial experience in a swine model.

    Science.gov (United States)

    Numburi, Uma D; Kapadia, Samir R; Schoenhagen, Paul; Tuzcu, E Murat; von Roden, Martin; Halliburton, Sandra S

    2013-02-01

    To determine the optimal C-arm computed tomography (CT) protocol for transcatheter aortic valve implantation (TAVI) in swine. In 6 swine, C-arm CT was performed using 5-s ungated acquisition during sinus rhythm with aortic root (Method 1) or peripheral (Method 2) injection, and during rapid ventricular pacing with root injection (Method 3). Additionally, 24-s ECG-gated acquisitions were performed during sinus rhythm with root (Method 4) or peripheral (Method 5) injection. Aortic root enhancement, presence of artifacts and contrast volumes were compared for all methods. Aortic root measurements were also compared between C-arm CT and multidetector-row computed tomography (MDCT). The best C-arm CT image set was identified and used to predict optimal angiographic projection angles during TAVI; predictions were compared to those from MDCT. Methods 1, 3, 4, and 5 yielded sufficient root enhancement with mild or moderate artifacts and aortic annulus, sinotubular junction, and mid-ascending aorta diameters similar to MDCT. Ungated C-arm CT (Methods 1, 3) required less contrast than ECG-gated C-arm CT (Methods 4, 5). Method 3 was optimal yielding images with high attenuation, few artifacts (2.0), and root measurements similar to MDCT using minimal contrast (36 mL). Predicted angiographic projections from Method 3 were similar to MDCT. Ungated C-arm CT during rapid pacing with aortic root injection required minimal contrast, yielded high attenuation and few artifacts, and aortic root measurements and predicted angiographic planes similar to those from MDCT.

  8. Injection of zinc in plants of ANAV. Impact on fuel and operation experience; Inyeccion de cinc en las plantas de ANAV. Impacto sobre el combustible y experiencia de operacion

    Energy Technology Data Exchange (ETDEWEB)

    Doncell, N.; Gago, J. L.

    2015-07-01

    Zinc injection performed in the three ANAV (Asociacion Nuclear Asco-Vandellos) plants is part of an overall primary water chemistry program, material management and dose reduction program. The application of zinc shown significant benefits in radiation field reduction as well as in mitigation of PWSCC initiation. Although zinc injection also reduces general corrosion rates and consequently reduces corrosion product transport to the fuel, and evaluation of the risks with respect to fuel performance should be done. ANAV and ENUSA, following industry recommendations, have coordinated the task related to the viability of the program in Asco and Vandellos including monitoring, inspections and control parameters. finally, this article includes a comprehensive review of operating experience and an assessment of fuel performance effects. (Author)

  9. Helpful tips for performing musculoskeletal injections.

    Science.gov (United States)

    Metz, John P

    2010-01-01

    Injections are valuable procedures for managing musculoskeletal conditions commonly encountered by family physicians. Corticosteroid injections into articular, periarticular, or soft tissue structures relieve pain, reduce inflammation, and improve mobility. Injections can provide diagnostic information and are commonly used for postoperative pain control. Local anesthetics may be injected with corticosteroids to provide additional, rapid pain relief. Steroid injection is the preferred and definitive treatment for de Quervain tenosynovitis and trochanteric bursitis. Steroid injections can also be helpful in controlling pain during physical rehabilitation from rotator cuff syndrome and lateral epicondylitis. Intra-articular steroid injection provides pain relief in rheumatoid arthritis and osteoarthritis. There is little systematic evidence to guide medication selection for therapeutic injections. The medication used and the frequency of injection should be guided by the goal of the injection (i.e., diagnostic or therapeutic), the underlying musculoskeletal diagnosis, and clinical experience. Complications from steroid injections are rare, but physicians should understand the potential risks and counsel patients appropriately. Patients with diabetes who receive periarticular or soft tissue steroid injections should closely monitor their blood glucose for two weeks following injection.

  10. Musculoskeletal injections: a review of the evidence.

    Science.gov (United States)

    Stephens, Mark B; Beutler, Anthony I; O'Connor, Francis G

    2008-10-15

    Injections are valuable procedures for managing musculoskeletal conditions commonly encountered by family physicians. Corticosteroid injections into articular, periarticular, or soft tissue structures relieve pain, reduce inflammation, and improve mobility. Injections can provide diagnostic information and are commonly used for postoperative pain control. Local anesthetics may be injected with corticosteroids to provide additional, rapid pain relief. Steroid injection is the preferred and definitive treatment for de Quervain tenosynovitis and trochanteric bursitis. Steroid injections can also be helpful in controlling pain during physical rehabilitation from rotator cuff syndrome and lateral epicondylitis. Intra-articular steroid injection provides pain relief in rheumatoid arthritis and osteoarthritis. There is little systematic evidence to guide medication selection for therapeutic injections. The medication used and the frequency of injection should be guided by the goal of the injection (i.e., diagnostic or therapeutic), the underlying musculoskeletal diagnosis, and clinical experience. Complications from steroid injections are rare, but physicians should understand the potential risks and counsel patients appropriately. Patients with diabetes who receive periarticular or soft tissue steroid injections should closely monitor their blood glucose for two weeks following injection.

  11. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to treat ... in the treatment of certain serious infections. Penicillin G procaine injection is in a class of medications ...

  12. Iron Dextran Injection

    Science.gov (United States)

    ... allergic to iron dextran injection; any other iron injections such as ferric carboxymaltose (Injectafer), ferumoxytol (Feraheme), iron sucrose (Venofer), or sodium ferric gluconate (Ferrlecit);any other ...

  13. Full scale calcium bromide injection with subsequent mercury oxidation and removal within wet flue gas desulphurization system: Experience at a 700 MW coal-fired power facility

    Science.gov (United States)

    Berry, Mark Simpson

    The Environmental Protection Agency promulgated the Mercury and Air Toxics Standards rule, which requires that existing power plants reduce mercury emissions to meet an emission rate of 1.2 lb/TBtu on a 30-day rolling average and that new plants meet a 0.0002 lb/GWHr emission rate. This translates to mercury removals greater than 90% for existing units and greater than 99% for new units. Current state-of-the-art technology for the control of mercury emissions uses activated carbon injected upstream of a fabric filter, a costly proposition. For example, a fabric filter, if not already available, would require a 200M capital investment for a 700 MW size unit. A lower-cost option involves the injection of activated carbon into an existing cold-side electrostatic precipitator. Both options would incur the cost of activated carbon, upwards of 3M per year. The combination of selective catalytic reduction (SCR) reactors and wet flue gas desulphurization (wet FGD) systems have demonstrated the ability to substantially reduce mercury emissions, especially at units that burn coals containing sufficient halogens. Halogens are necessary for transforming elemental mercury to oxidized mercury, which is water-soluble. Plants burning halogen-deficient coals such as Power River Basin (PRB) coals currently have no alternative but to install activated carbon-based approaches to control mercury emissions. This research consisted of investigating calcium bromide addition onto PRB coal as a method of increasing flue gas halogen concentration. The treated coal was combusted in a 700 MW boiler and the subsequent treated flue gas was introduced into a wet FGD. Short-term parametric and an 83-day longer-term tests were completed to determine the ability of calcium bromine to oxidize mercury and to study the removal of the mercury in a wet FGD. The research goal was to show that calcium bromine addition to PRB coal was a viable approach for meeting the Mercury and Air Toxics Standards rule

  14. Transient Enhancement ('Spike-on-Tail') Observed on Neutral-Beam-Injected Energetic Ion Spectra Using the E||B Neutral Particle Analyzer in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Medley, S. S. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Gorelenkov, N. N. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Bell, R. E. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Fredrickson, E. D. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Gerhardt, S. P. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); LeBlanc, B. P. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Podesta, M. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Roquemore, A. L. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)

    2010-06-01

    An increase of up to four-fold in the E||B Neutral Particle Analyzer (NPA) charge exchange neutral flux localized at the Neutral Beam (NB) injection full energy is observed in the National Spherical Torus Experiment (NSTX). Termed the High-Energy Feature (HEF), it appears on the NB-injected energetic ion spectrum only in discharges where tearing or kink-type modes (f < 10 kHz) are absent, TAE activity (f ~ 10-150 kHz) is weak (δBrms < 75 mGauss) and CAE/GAE activity (f ~ 400 – 1200 kHz) is robust. The feature exhibits a growth time of ~ 20 - 80 ms and occasionally develops a slowing down distribution that continues to evolve over periods of 100's of milliseconds, a time scale long compared with the typical ~ 10's ms equilibration time of the NB injected particles. The HEF is observed only in H-mode (not L-mode) discharges with injected NB power of 4 MW or greater and in the field pitch range v||/v ~ 0.7 – 0.9; i.e. only for passing (never trapped) energetic ions. The HEF is suppressed by vessel conditioning using lithium deposition at rates ~ 100 mg/shot, a level sufficient to suppress ELM activity. Increases of ~ 10 - 30 % in the measured neutron yield and total stored energy are observed to coincide with the feature along with broadening of measured Te(r), Ti(r) and ne(r) profiles. However, TRANSP analysis shows that such increases are driven by plasma profile changes and not the HEF phenomenon itself. Though a definitive mechanism has yet to be developed, the HEF appears to be caused by a form of TAE/CAE wave-particle interaction that distorts of the NB fast ion distribution in phase space.

  15. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...

  16. Surgical management of stress urinary incontinence: Burch colposuspension, modified Pereyra and Stamey bladder neck suspension, and collagen injection--Toa Payoh Hospital experience.

    Science.gov (United States)

    Tay, K P; Lim, P H; Chng, H C

    1995-12-01

    A retrospective analysis was performed on 34 female patients who underwent corrective surgery for stress urinary incontinence over a 4-year period at the Toa Payoh Hospital. These patients were offered surgery only after an adequate trial of medical therapy, pelvic floor exercises and weight reduction. Bladder neck suspension operations were performed via the Burch, Stamey and modified Pereyra techniques. Towards the later part of this study, endoscopic injection of Collagen was performed as a salvage procedure in 2 patients. The Burch colposuspension gave uniformly good results, with all patients being completely dry. Seventy percent and sixty percent complete continence were achieved via the modified Pereyra and Stamey techniques respectively. Three patients required additional surgical procedures. Using these techniques, the overall results showed that 27 patients (79.4%) had complete urinary continence following surgery, while the remaining 7 patients (20.6%) experienced significant improvement of symptoms.

  17. Sipuleucel-T Injection

    Science.gov (United States)

    Sipuleucel-T injection is used to treat certain types of advanced prostate cancer. Sipuleucel-T injection is in a class of medications called ... Sipuleucel-T injection comes as a suspension (liquid) to be injected over about 60 minutes into a vein ...

  18. Experiments on gas injection mechanisms in carbonate fracture-cavity reservoir using microvisual model%碳酸盐岩缝洞型油藏气驱机制微观可视化模型试验

    Institute of Scientific and Technical Information of China (English)

    郭平; 袁恒璐; 李新华; 马洪涛

    2012-01-01

    In fracture-cavity carbonate reservoirs,there are generally two kinds of fracture-cavities whose fracture opening are upward and downward respectively. A microvisual model was established to investigate the displacement mechanisms of gas and liquid flooding. Under normal temperature and low pressure, simulated oil and liquid gas were used to do four groups of experiments including water displacement, active water displacement, direct gas displacement and gas-alternating-water displacement. And the effects of different injected fluids and injected methods on displacement efficiency and water cut were researched. The results show that the displacement efficiencies of water displacement, active water displacement, gas displacement and gas-alternating-water displacement are 81. 12% , 68. 95% , 74. 88% and 99. 84% , respectively. The best injection method is gas-alternating-water in fracture-cavity reservoir. Gas injection can only displace the oil in cavities whose fracture openings are downward, and water injection can only displace those whose fracture openings are upward, but gas-alternating-water method can settle down both. Due to the low capillary pressure, active water is no good for oil displacement.%针对缝洞型碳酸盐岩油藏开发中开口向上和开口向下两种缝洞类型,建立该类油藏气驱机制下的微观可视模型,采用模拟油和液化气,在常温低压下进行水驱、活性水驱、直接注气驱及气-水交替驱4组试验,研究不同注入流体及注入方式对驱替效率和含水率的影响.结果表明:水驱、活性水驱、气驱和气-水交替驱的驱替效率分别为81.12%、68.95%、74.88%和99.84%,缝洞型油藏的最佳注入方式为气-水交替注入;注气只能驱开向下的洞,注水只能驱替开口向上的洞,气-水交替驱可以同时解决这两种洞的驱油问题;活性水由于毛管压力低不利于驱油.

  19. The influence of plasma horizontal position on the neutron rate and flux of neutral atoms in injection heating experiment on the TUMAN-3M tokamak

    Science.gov (United States)

    Kornev, V. A.; Chernyshev, F. V.; Melnik, A. D.; Askinazi, L. G.; Wagner, F.; Vildjunas, M. I.; Zhubr, N. A.; Krikunov, S. V.; Lebedev, S. V.; Razumenko, D. V.; Tukachinsky, A. S.

    2013-11-01

    Horizontal displacement of plasma along the major radius has been found to significantly influence the fluxes of 2.45 MeV DD neutrons and high-energy charge-exchange atoms from neutral beam injection (NBI) heated plasma of the TUMAN-3M tokamak. An inward shift by Δ R = 1 cm causes 1.2-fold increase in the neutron flux and 1.9-fold increase in the charge-exchange atom flux. The observed increase in the neutron flux is attributed to joint action of several factors-in particular, improved high-energy ion capture and confinement and, probably, decreased impurity inflow from the walls, which leads to an increase in the density of target ions. A considerable increase in the flux of charge-exchange neutrals in inward-shifted plasma is due to the increased number of captured high-energy ions and, to some extent, the increased density of the neutral target. As a result of the increase in the content of high-energy ions, the central ion temperature T i (0) increased from 250 to 350 eV. The dependence of the neutron rate on major radius R 0 should be taken into account when designing compact tokamak-based neutron sources.

  20. First experience with intracytoplasmic sperm injection for extreme oligozoospermia associated with Crohn‘s disease and 6—mercaptopurine chemotherapy

    Institute of Scientific and Technical Information of China (English)

    E.ScottSills; MichaelJ.Tucker

    2003-01-01

    Aim:To describe the reproductive outcome following intracytoplasmic sperm injection(ICSI)for male factor infertility associated with Crohn's disease and 6-mercaptopurine(6-MP) chemotherapy.Methods:The male partner of a couple suffered from severe Crohn's disease and received a 3-month course of 6-MP for this condition.Two spontaneous conceptions were established before 6-MP,although post-chemotherapy semen analysis found the sperm concentration to be 8,000/mL.In vitro fertilization(IVF)with ICSI and embryo transfer was performed.Results:The woman underwent an uncomplicated controlled ovarian hyperstimulation sequence using a combined rec-FSH+hMG protocol,following late luteal phase pituitary downregulation.This culminated in the retrieval of 18 oocytes,11 of which were fertilized with ICSI.She later delivered a normal male infant without urogenital anomaly.Four nontransferred blastocysts were cryopreserved.Conclusion:This report describes the first successful birth after ICSI for severe oligozoospermia associated with Crohn''''s disease and 6-MP therapy.We outline salient features of Crohn's disease,6-MP pharmacology,and their relevance to human fertility.

  1. On Maximal Injectivity

    Institute of Scientific and Technical Information of China (English)

    Ming Yi WANG; Guo ZHAO

    2005-01-01

    A right R-module E over a ring R is said to be maximally injective in case for any maximal right ideal m of R, every R-homomorphism f : m → E can be extended to an R-homomorphism f' : R → E. In this paper, we first construct an example to show that maximal injectivity is a proper generalization of injectivity. Then we prove that any right R-module over a left perfect ring R is maximally injective if and only if it is injective. We also give a partial affirmative answer to Faith's conjecture by further investigating the property of maximally injective rings. Finally, we get an approximation to Faith's conjecture, which asserts that every injective right R-module over any left perfect right self-injective ring R is the injective hull of a projective submodule.

  2. Effect of Injection Flow Rate on Product Gas Quality in Underground Coal Gasification (UCG Based on Laboratory Scale Experiment: Development of Co-Axial UCG System

    Directory of Open Access Journals (Sweden)

    Akihiro Hamanaka

    2017-02-01

    Full Text Available Underground coal gasification (UCG is a technique to recover coal energy without mining by converting coal into a valuable gas. Model UCG experiments on a laboratory scale were carried out under a low flow rate (6~12 L/min and a high flow rate (15~30 L/min with a constant oxygen concentration. During the experiments, the coal temperature was higher and the fracturing events were more active under the high flow rate. Additionally, the gasification efficiency, which means the conversion efficiency of the gasified coal to the product gas, was 71.22% in the low flow rate and 82.42% in the high flow rate. These results suggest that the energy recovery rate with the UCG process can be improved by the increase of the reaction temperature and the promotion of the gasification area.

  3. Solid Organic Deposition During Gas Injection Studies

    DEFF Research Database (Denmark)

    Dandekar, Abhijit Y.; Andersen, Simon Ivar; Stenby, Erling Halfdan

    2000-01-01

    Recently a series of first contact miscibility (swelling) experiments have been performed on undersaturated light and heavy oils using LPG rich and methane rich injection gases, in which solid organic deposition was observed. A compositional gradient in the oils during the gas injection process w...

  4. Aplicação das técnicas de planejamento e análise de experimentos no processo de injeção plástica Application design of experiments in the injection molding process

    Directory of Open Access Journals (Sweden)

    Edwin V. Cardoza Galdamez

    2004-04-01

    Full Text Available Experimentos industriais são realizados pelas empresas com o intuito de melhorar o desempenho dos produtos e os processos de fabricação. Nesse sentido, este trabalho tem por objetivo estudar e aplicar as técnicas de planejamento e análise de experimentos na melhoria da qualidade industrial. Especificamente são aplicadas as técnicas de planejamento Fatorial Fracionado 2k-p, Metodologia de Superfície de Resposta e Análise de Variância, em um processo de moldagem por injeção plástica. Com essa pesquisa experimental foi possível identificar os níveis ótimos de regulagem e os parâmetros mais importantes da injeção plástica: temperatura da máquina e pressão de injeção. Para finalizar é avaliado o procedimento de implementação das técnicas de experimentação e as dificuldades práticas encontradas na empresa.Industrial experiments are made by companies in order to improve the quality characteristics of products and production processes. In this sense, the objective of this paper is to study and apply the design of experiments in the industrial quality improvement. In addition, as a part of the objective, an application of the techniques of design Fractional Factorial 2k-p, Analysis of Variance and Response Surface Methodology is done. It is focused in an injection molding process applied by a company, that makes and trades plastic products for the civil construction. Using this experimental study, the most important parameters of plastic injection are identified: machine temperature and injection pressure. At the same time, the optimal levels of adjustment of these parameters are determined. From this study, it is evaluated both the implantation procedures of the designs of experiments as well as the difficulties faced. Also, this study tries to contribute to the university-company relationship.

  5. Epoetin Alfa Injection

    Science.gov (United States)

    ... Combivir), a medication used to treat human immunodeficiency virus (HIV). Epoetin alfa injection is also used before ... inject epoetin alfa, as directed by your doctor. Write down the date, time, dose of epoetin alfa ...

  6. Collagenase Clostridium Histolyticum Injection

    Science.gov (United States)

    Collagenase Clostridium histolyticum injection is used to treat Dupuytren's contracture (a painless thickening and tightening of tissue [cord] beneath ... of tissue can be felt upon examination. Collagenase Clostridium histolyticum injection is also used to treat Peyronie's ...

  7. Iron Sucrose Injection

    Science.gov (United States)

    Iron sucrose injection is used treat iron-deficiency anemia (a lower than normal number of red blood cells due ... and may cause the kidneys to stop working). Iron sucrose injection is in a class of medications called iron ...

  8. Intracytoplasmic sperm injection

    Science.gov (United States)

    Intracytoplasmic sperm injection, or ICSI, is a form of in vitro fertilization in which fertilization occurs outside of the ... laboratory dish. Within a few hours, a single sperm is injected through a fine needle into the ...

  9. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  10. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  11. Other Injectable Medications

    Science.gov (United States)

    ... July 17, 2013 Last Edited: February 22, 2017 Articles from Diabetes Forecast® magazine: cg-infusion-sets,meds-bg-injectables,cg-injection-aids, In this section Treatment and Care Medication Insulin & ...

  12. Injection losses and protection

    CERN Document Server

    Bartmann, W; Baudrenghien, P; Bracco, C; Dehning, B; Di Mauro, A; Drosdal, L; Emery, J; Goddard, B; Holzer, E B; Höfle, W; Kain, V; Meddahi, M; Radaelli, S; Shaposhnilova, E; Uythoven, J; Valuch, D; Wenninger, J; Zamantzas, C; Gianfelice-Wendt, E

    2012-01-01

    Injection losses are compared for 2010 and 2011 operation. Mitigation techniques which were put in place in 2010 to reduce losses at injection are described. Issues in 2011 operation, their potential improvements and the performance reach for 2012 are shown.

  13. Beam injection into RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

    1997-07-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

  14. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  15. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  16. 有静脉注射海洛因病史患者30例中心静脉穿刺置管体会%Experience of central venous catheterization on 30 patients with a history of heroin injection

    Institute of Scientific and Technical Information of China (English)

    何吉飞

    2016-01-01

    目的:探讨有静脉注射海洛因病史的患者行中心静脉穿刺置管术的方法。方法:对30例有静脉注射海洛因病史的患者行中心静脉穿刺置管术。结果:30例中心静脉穿刺置管均成功,其中1次穿刺成功23例,更换部位后穿刺成功7例。穿刺部位:右侧锁骨下19例,右侧颈内8例,左侧颈内3例。结论:静脉注射海洛因患者中心静脉穿刺置管较困难,通过积累经验,充分准备,熟练操作,才能提高对该类患者中心静脉穿刺置管成功率。%Objective:To investigate the method of central venous catheterization in patients with a history of heroin injection. Methods:30 patients with a history of heroin injection were treated with central venous catheterization.Results:All of those 30 cases with central venous catheterization were successful,in which there were 23 cases successful puncture at once,another 7 cases were successful puncture after changing the puncture site.Puncture site:19 cases on the right side of the clavicle,8 cases on the right side of the neck,3 cases on the left side of the internal carotid.Conclusion:Central venous catheterization on patient with a history of intravenous injection of heroin is more difficult,need to accumulate experience,fully prepared and skilled operation,to improve the success rate of the central vein puncture catheter.

  17. Endovascular treatment for dural arteriovenous fistula at the foramen magnum: report of five consecutive patients and experience with balloon-augmented transarterial Onyx injection.

    Science.gov (United States)

    Liang, Guobiao; Gao, Xu; Li, Zhiqing; Wang, Xiaogang; Zhang, Haifeng; Wu, Zhongxue

    2013-05-01

    Foramen magnum dural arteriovenous fistulas (DAVF) with perimedullary venous drainage represent a small minority of intracranial DAVF, and only a number of small series with limited cases have been reported. The purpose of this retrospective study is to summarize experience of transarterial Onyx embolisation in the treatment of these lesions, with emphasis on the balloon-augmented technique. Five consecutive patients with DAVF at the foramen magnum were treated by transarterial embolisation using the Onyx system. Their symptoms included myelopathy (n=4) and SAH (n=1). Suppliers were from the vertebral artery (VA) (n=4), occipital artery (OA) (n=4), and ascending pharyngeal artery (APA) (n=2), with drainage to the perimedullary veins. After catheterization of the dilated supplier, the fistulous connections, proximal draining veins and appropriate distal segment of the feeders of these DAVF were transarterial embolized using Onyx-18. In three patients, balloon-augmented technique was used to assist embolisation. The technical feasibility of the procedure, angiographic results, and clinical outcome were evaluated. In every case, complete obliteration was achieved. Neither intraprocedural vessel rupture nor other procedure-related complications occurred. The results remained stable in all patients on follow-up angiograms (mean, 7.2 months). At the last clinical follow-up (mean, 17.6 months), two patients showed complete resolution of the initial symptoms, and three patients showed significant improvement. We found that Onyx embolisation is a feasible and safe alternative to open surgery in the treatment of selective DAVF at the foramen magnum. The balloon-augmented technique widens indications for transarterial Onyx packing of these lesions, and improved safety of the procedure. Copyright © 2013. Published by Elsevier Masson SAS.

  18. Epidural injections for back pain

    Science.gov (United States)

    ESI; Spinal injection for back pain; Back pain injection; Steroid injection - epidural; Steroid injection - back ... be pregnant What medicines you are taking, including herbs, supplements, and other drugs you bought without a ...

  19. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  20. Underground Injection Control (UIC)

    Science.gov (United States)

    Provide information on: individual injection well classes; regulations specific to each well class; technical guidance; compliance assistance; federal, state, and tribal/territory roles and responsibilities.

  1. Ferric Carboxymaltose Injection

    Science.gov (United States)

    ... pharmacist if you are allergic to ferric carboxymaltose injection, ferumoxytol (Feraheme), iron dextran (Dexferrum, Infed), iron sucrose (Venofer), or sodium ferric gluconate (Ferrlecit); any other ...

  2. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  3. Hot carrier injection degradation under dynamic stress

    Institute of Scientific and Technical Information of China (English)

    Ma Xiao-Hua; Cao Yan-Rong; Hao Yue; Zhang Yue

    2011-01-01

    In this paper, we have studied hot carrier injection (HCI) under alternant stress. Under different stress modes, different degradations are obtained from the experiment results. The different alternate stresses can reduce or enhance the HC effect, which mainly depends on the latter condition of the stress cycle. In the stress mode A (DC stress with electron injection), the degradation keeps increasing. In the stress modes B (DC stress and then stress with the smallest gate injection) and C (DC stress and then stress with hole injection under Vg=0V and Vd = 1.8 V), recovery appears in the second stress period. And in the stress mode D (DC stress and then stress with hole injection under Vg = -1.8 V and Vd = 1.8 V), as the traps filled in by holes can be smaller or greater than the generated interface states, the continued degradation or recovery in different stress periods can be obtained.

  4. Application of Gaseous Sphere Injection Method for Modeling Under-expanded H2 Injection

    Energy Technology Data Exchange (ETDEWEB)

    Whitesides, R; Hessel, R P; Flowers, D L; Aceves, S M

    2010-12-03

    A methodology for modeling gaseous injection has been refined and applied to recent experimental data from the literature. This approach uses a discrete phase analogy to handle gaseous injection, allowing for addition of gaseous injection to a CFD grid without needing to resolve the injector nozzle. This paper focuses on model testing to provide the basis for simulation of hydrogen direct injected internal combustion engines. The model has been updated to be more applicable to full engine simulations, and shows good agreement with experiments for jet penetration and time-dependent axial mass fraction, while available radial mass fraction data is less well predicted.

  5. Influence of Injection and Cavity Pressure on the Demoulding Force in Micro-Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.G.

    2014-01-01

    of four process parameters, melt temperature, mould temperature, holding pressure, and injection speed, employing the design of experiment approach. In addition, the results obtained using different combinations of process parameters were analyzed to identify the best processing conditions in regards...

  6. [Intra-articular injections].

    Science.gov (United States)

    Chapelle, Ch

    2015-09-01

    It is not unusual for a specialist or general practitioner to be presented with a pathology which necessitates the use of an intra-articular injection of corticosteroids, hyaluronic acid or a local anaesthetic. It would seem to be interesting to update and to precise the techniques and methods of intraarticular injections which have appeared in recent international publications, when we know that 30 % of the injections given into the knee and so called "dry" are incorrect and, therefore, inefficient. The indication of an articular injection depends, firstly, on the diagnosis which should be done with great care; after which should be an objective analysis complete with secondary effects linked to both the injection and the product used. The conditions of asepsis, the choice of needles and quantities of the injection and even the ways of the injections should be reviewed in detail. The last studies clearly question the secondary effects of the cartilage degradations of the cortisone given as an intra-articular injection and shows its efficiency on the pain and inflammatory phenomonen in osteoarthritis. Studies on hyaluronic acid are often contradictory going from a modest result to an important pain relief but it is necessary to be aware that the objective criteria are difficult to interpret. The use of local anaesthetics in intra-articular is limited by the few indications in view of the major risk of aggravating the pre-existing lesions by the disappearing signs of pain.

  7. Injection of Deuterium Pellets

    DEFF Research Database (Denmark)

    Sørensen, H.; Andersen, P.; Andersen, S. A.

    1984-01-01

    A pellet injection system made for the TFR tokamak at Fontenay-aux-Roses, Paris is described. 0.12-mg pellets are injected with velocities of around 600-700 m/s through a 5-m long guide tube. Some details of a new light gas gun are given; with this gun, hydrogen pellets are accelerated...

  8. Corticotropin, Repository Injection

    Science.gov (United States)

    H.P. Acthar Gel® ... Corticotropin repository injection comes as a long acting gel to inject under the skin or into a ... prescription and nonprescription medications, vitamins, nutritional supplements, or herbal products you are taking or plan to take. ...

  9. Separably injective Banach spaces

    CERN Document Server

    Avilés, Antonio; Castillo, Jesús M F; González, Manuel; Moreno, Yolanda

    2016-01-01

    This monograph contains a detailed exposition of the up-to-date theory of separably injective spaces: new and old results are put into perspective with concrete examples (such as l∞/c0 and C(K) spaces, where K is a finite height compact space or an F-space, ultrapowers of L∞ spaces and spaces of universal disposition). It is no exaggeration to say that the theory of separably injective Banach spaces is strikingly different from that of injective spaces. For instance, separably injective Banach spaces are not necessarily isometric to, or complemented subspaces of, spaces of continuous functions on a compact space. Moreover, in contrast to the scarcity of examples and general results concerning injective spaces, we know of many different types of separably injective spaces and there is a rich theory around them. The monograph is completed with a preparatory chapter on injective spaces, a chapter on higher cardinal versions of separable injectivity and a lively discussion of open problems and further lines o...

  10. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    effects of DME in high pressure injection have also been observed. DME has a higher compressibility than diesel fuel, resulting in larger pressure oscillations in the injection system during the injection process. The oscillations with DME also have a slower delay rate than those of diesel fuel......A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump...... in the same system. As a first attempt to simulate combustion of DME in Diesel engines, the results of the spray studies have been incorporated into a simplified spray combustion model. A turbulent jet structure was adjusted to fit the penetration rates of the observed sprays. The observed spray widths agreed...

  11. Dependency injection with AngularJS

    CERN Document Server

    Knol, Alex

    2013-01-01

    This book is a practical, hands-on approach to using dependency injection and implementing test-driven development using AngularJS. Dependency Injection with AngularJS is aimed at developers who are aware of AngularJS but need to get started with using it in real life applications. Also, developers who want to get into test-driven development with AngularJS can use this book as practical guide. Even if you know about dependency injection, it can serve as a good reference on how it is used within AngularJS. Readers are expected to have some experience with JavaScript.

  12. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...... index of the nanostructured surfaces was estimated from atomic force micrographs and the theoretical reflectance was calculated using the transfer matrix method and effective medium theory. The measured reflectance shows good agreement with the theory of graded index antireflective nanostructures...

  13. ALICE Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The ALICE (point 2) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for ALICE are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the ALICE vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  14. LHCb Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The LHCb (point 8) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for LHCb are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the LHCb vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  15. Common injections in musculoskeletal medicine.

    Science.gov (United States)

    Monseau, Aaron J; Nizran, Parminder Singh

    2013-12-01

    Musculoskeletal injections are a common procedure in primary care and sports medicine but can be intimidating for some clinicians. This article addresses current evidence for corticosteroid injections, and common injection indications and techniques, namely knee, subacromial bursa, glenohumeral joint, lateral epicondyle, de Quervain tenosynovitis, and greater trochanteric bursa injections. Preparation for injections and some evidence for ultrasound guidance are also reviewed.

  16. Mouse bladder wall injection.

    Science.gov (United States)

    Fu, Chi-Ling; Apelo, Charity A; Torres, Baldemar; Thai, Kim H; Hsieh, Michael H

    2011-07-12

    Mouse bladder wall injection is a useful technique to orthotopically study bladder phenomena, including stem cell, smooth muscle, and cancer biology. Before starting injections, the surgical area must be cleaned with soap and water and antiseptic solution. Surgical equipment must be sterilized before use and between each animal. Each mouse is placed under inhaled isoflurane anesthesia (2-5% for induction, 1-3% for maintenance) and its bladder exposed by making a midline abdominal incision with scissors. If the bladder is full, it is partially decompressed by gentle squeezing between two fingers. The cell suspension of interest is intramurally injected into the wall of the bladder dome using a 29 or 30 gauge needle and 1 cc or smaller syringe. The wound is then closed using wound clips and the mouse allowed to recover on a warming pad. Bladder wall injection is a delicate microsurgical technique that can be mastered with practice.

  17. IncobotulinumtoxinA Injection

    Science.gov (United States)

    ... injected into a muscle, it blocks the nerve signals that cause uncontrollable tightening and movements of the ... any of these symptoms, do not drive a car, operate machinery, or do other dangerous activities.if ...

  18. Amphotericin B Liposomal Injection

    Science.gov (United States)

    ... lining of the spinal cord and brain) and visceral leishmaniasis (a parasitic disease that usually affects spleen, ... complex injection: fever, chills, nausea, vomiting, flushing, back pain with or without chest tightness, chest pain, shortness ...

  19. PS injection area

    CERN Multimedia

    1974-01-01

    To the right is the PS ring viewed along the direction of the protons. At the left the injection line coming from the 50 MeV Linac 1 (bottom) and going towards the 800 MeV booster, or deflected to the right to be injected directly into straight section 16. The drumlike element behind the (blue) dipole magnet is a 'debuncher' (a 200 MHz cavity). See photos 7409014X and 7409009.

  20. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  1. Quasi-stable injection channels in a wakefield accelerator

    Science.gov (United States)

    Wiltshire-Turkay, Mara; Farmer, John P.; Pukhov, Alexander

    2016-05-01

    The influence of initial position on the acceleration of externally injected electrons in a plasma wakefield is investigated. Test-particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the wake centre. Particles injected into these channels remain in the wake for a considerable time after dephasing and as a result achieve significantly higher energy than their neighbours. The result is relevant to both the planning and optimisation of experiments making use of external injection.

  2. Backfire prediction in a manifold injection hydrogen internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xing-hua; Liu, Fu-shui; Zhou, Lei; Sun, Bai-gang [School of Mechanical and Vehicular Engineering, Beijing Institute of Technology, Beijing 100081 (China); Schock, Harold J. [Engine Research Laboratory, Michigan State University, East Lansing, MI (United States)

    2008-07-15

    Hydrogen internal combustion engine (H2ICE) easily occur inlet manifold backfire and other abnormal combustion phenomena because of the low ignition energy, wide flammability range and rapid combustion speed of hydrogen. In this paper, the effect of injection timing on mixture formation in a manifold injection H2ICE was studied in various engine speed and equivalence ratio by CFD simulation. It was concluded that H2ICE of manifold injection have an limited injection end timing in order to prevent backfire in the inlet manifold. Finally, the limit of injection end timing of the H2ICE was proposed and validated by engine experiment. (author)

  3. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    Directory of Open Access Journals (Sweden)

    Tolga Karakan

    2012-01-01

    Full Text Available Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  4. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  5. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  6. Fault Injection Techniques and Tools

    Science.gov (United States)

    Hsueh, Mei-Chen; Tsai, Timothy K.; Iyer, Ravishankar K.

    1997-01-01

    Dependability evaluation involves the study of failures and errors. The destructive nature of a crash and long error latency make it difficult to identify the causes of failures in the operational environment. It is particularly hard to recreate a failure scenario for a large, complex system. To identify and understand potential failures, we use an experiment-based approach for studying the dependability of a system. Such an approach is applied not only during the conception and design phases, but also during the prototype and operational phases. To take an experiment-based approach, we must first understand a system's architecture, structure, and behavior. Specifically, we need to know its tolerance for faults and failures, including its built-in detection and recovery mechanisms, and we need specific instruments and tools to inject faults, create failures or errors, and monitor their effects.

  7. Experiment on single well groundwater heat pump systems in different distances between pumping and injection screens%不同抽回间距的单井循环地下水源热泵系统试验

    Institute of Scientific and Technical Information of China (English)

    宋伟; 倪龙; 姚杨

    2014-01-01

    As the global energy crises and environmental problems become more and more serious, ground source heat pump (GSHP) systems are perhaps the most widely used green HVAC system, with an estimated 1.1 million ground source heat pumps installed worldwide. These systems have become an important energy-saving and environment protection technology for use in residential and commercial buildings in China. These applications included two types of systems: closed-loop (ground-coupled) and open-loop. As one kind of semi-closed-loop systems, single well groundwater heat pump (SWGWHP) systems have become increasingly popular for use because of their economic advantages from lower installation cost, lower operating cost, and improved overall performance in regions with suitable geological conditions. In general, SWGWHP systems included three different variations, i.e. standing column well (SCW) system, pumping & recharging well (PRW) system, and pumping&recharging well filled with gravel (PRWFG) system. Compared with SCW system, the well pipe in PRW system and PRWFG system are divided into three parts by clapboards, i.e. production zone, seals zone and injection zone. In recent decades, considerable research efforts have been spent on SWGWHP systems, especially on SCW system. However, little attention has been focused on the PRW system and PRWFG system. For GSHP systems, sand tank experiment is one of the important methods of laboratory investigation for discussing the performance of geothermal heat exchanger, due to many parameters can be set and adjusted more easily and economically than that in in-situ experiments. In order to provide a framework for discussing the influence on distances between pumping and injection screens (DPI) in SWGWHP systems, a sand tank experiment system was designed and set up in Harbin Institute of Technology, China. In this study, we tested the temperature of outlet and inlet water, the aquifer temperature, and flow rate of outlet water. From the

  8. Demonstration of steady inductive helicity injection

    Science.gov (United States)

    Sieck, P. E.; Jarboe, T. R.; Izzo, V. A.; Hamp, W. T.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.

    2006-02-01

    Initial results demonstrating the concept of constant inductive helicity injection are presented. Constant helicity injection is achieved using two oscillating inductive helicity injectors, with the goal of producing a bow tie spheromak. Each injector is a 180° segment of a reverse field pinch and they are driven 90° out of phase. Approximately 5 MW of power is injected during the 6 ms pulse, and the input power has been maintained at a fairly constant value by directly fuelling the injectors with neutral gas. Motivation for the experiment is given, including beta-limit calculations for the bow tie spheromak. Fuelling the injectors with neutral gas during the discharge is shown to produce injector parameters that are more constant in time. A series of discharges with increasing power input shows a promising increase in toroidal current. Unique construction techniques of the experiment are also described.

  9. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.;

    2010-01-01

    has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been...

  10. Intracytoplasmic Sperm Injection (ICSI)

    Science.gov (United States)

    ... sperm must attach to the outside of the egg. Once attached, the sperm pushes through the outer layer to the inside ... in vitro fertilization (IVF) to help fertilize the egg. During ICSI, a single sperm is injected directly into the cytoplasm the egg. ...

  11. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  12. Giving an insulin injection

    Science.gov (United States)

    ... an alcohol wipe on your injection site. The insulin needs to go into the fat layer under the skin. Pinch the skin and put the needle in at a 45º angle. If your tissues are thick enough, you may be able to ...

  13. Computational Study of Combustion Dynamics in a Single-Element Lean Direct Injection Gas Turbine Combustor

    Science.gov (United States)

    2013-12-01

    spray injection models , viz., Log Normal Distributed Drop Injection Model , Single Drop Injection Model and Hollow Cone Injection Model , have...not match experiment. The hollow cone injection model was able to predict the correct dominant acoustic mode (4L) but the pressure amplitude was...processes of pressure-swirl hollow - cone fuel sprays ," Atomization and Sprays , vol. 7, pp. 663-684, Nov-Dec 1997. 22 M. A. Patterson and R. D.

  14. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...... has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been...

  15. TECHNOLOGICAL WASTE DISPOSAL BY SUBSURFACE INJECTION TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Janković Branimir

    2002-12-01

    Full Text Available The application of oilfield and solution mining technology to subsurface disposal of technological wastes has proven to be an environmentally, technically and economically suitable method for the disposal of the waste generated in petroleum industry as well as other industrial branches. This paper describes the subsurface injection technology, the disposal formation characteristics, the waste disposal well design, evaluates the environmental impact of above mentioned technology and proposes a solutions for disposing of technological wastes in Croatia or nerby region by implementing underground injection technology according to the world experience (the paper is published in Croatian.

  16. Effect of Functional Nano Channel Structures Different Widths on Injection Molding and Compression Molding Replication Capabilities

    DEFF Research Database (Denmark)

    Calaon, M.; Tosello, G.; Garnaes, J.

    The present study investigates the capabilities of the two employed processes, injection molding (IM) and injection compression molding (ICM) on replicating different channel cross sections. Statistical design of experiment was adopted to optimize replication quality of produced polymer parts wit...

  17. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  18. SPS injection kicker magnet

    CERN Multimedia

    1975-01-01

    One of the first-generation SPS injection kicker magnets, view of the complete tank. First proton beam from the PS was injected into the SPS in 1976, at a beam momentum of 10 GeV/c. These kickers served until the end of 1979 and were replaced at the beginning of 1980 by stronger ones, in preparation for the SPS as a proton-antiproton collider. For this, transfer momentum from the PS to the SPS was raised to 26 GeV/c, so as to avoid acceleration of the dense p and pbar bunches through SPS transition energy. Bearded Roland Tröhler is at the left, Giacomo Busetta smiles at the right. See also 7502073X, 7502074X and Annual Report 1975, 162.

  19. Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience; Angiografia rotazionale tridimensionale delle carotidi mediante iniezione ad alto flusso dell'arco aortico. Esperienza preliminare

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, Fabio; Calgaro, Antonio; Bruni, Stefano; Bottaro, Lorella; Pozzi Mucelli, Roberto [Trieste Univ., Trieste (Italy). Unita' Clinico Operativa di Radiologia

    2005-02-01

    Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded Surface Display), automatically remove bone structures (cervical spine, calcified plaque, etc) and perform an automatic analysis of the vessel diameter and surface area at the point of major stenosis and in the disease-free vessel segments above and below. The carotid evaluation was done either with selective catheterization and the two standard AP and LL projections and with RA after contrast medium injection from the aortic arch followed by 3D reconstruction. Results: The comparison of the selective angiography and three-dimensional images was possible in 37 out of 40 carotid bifurcations (3 internal carotid arteries were occluded) and a good diagnostic quality was obtained in 35 out of 37 cases with an high correlation in the degree of stenosis. In 2/37 cases with calcified plaques the degree of stenosis was effectively demonstrated only after electronic subtraction of the calcified component of the plaque. Conclusions: The technique we propose proved to be feasible in all cases with a good correlation

  20. PS injection area

    CERN Multimedia

    1974-01-01

    Looking against the direction of protons in the main ring (left): the beam coming from the linac 1 either goes to the booster (on the right) or is deflected towards the PS to be directly injected into section 26 (facing the camera). Also shown the start of the TT2 line, ejected from straight section 16 to go towards the ISR passing over the beam line from the linac. (see Photo Archive 7409009)

  1. Injection-induced earthquakes.

    Science.gov (United States)

    Ellsworth, William L

    2013-07-12

    Earthquakes in unusual locations have become an important topic of discussion in both North America and Europe, owing to the concern that industrial activity could cause damaging earthquakes. It has long been understood that earthquakes can be induced by impoundment of reservoirs, surface and underground mining, withdrawal of fluids and gas from the subsurface, and injection of fluids into underground formations. Injection-induced earthquakes have, in particular, become a focus of discussion as the application of hydraulic fracturing to tight shale formations is enabling the production of oil and gas from previously unproductive formations. Earthquakes can be induced as part of the process to stimulate the production from tight shale formations, or by disposal of wastewater associated with stimulation and production. Here, I review recent seismic activity that may be associated with industrial activity, with a focus on the disposal of wastewater by injection in deep wells; assess the scientific understanding of induced earthquakes; and discuss the key scientific challenges to be met for assessing this hazard.

  2. Injection-induced earthquakes

    Science.gov (United States)

    Ellsworth, William L.

    2013-01-01

    Earthquakes in unusual locations have become an important topic of discussion in both North America and Europe, owing to the concern that industrial activity could cause damaging earthquakes. It has long been understood that earthquakes can be induced by impoundment of reservoirs, surface and underground mining, withdrawal of fluids and gas from the subsurface, and injection of fluids into underground formations. Injection-induced earthquakes have, in particular, become a focus of discussion as the application of hydraulic fracturing to tight shale formations is enabling the production of oil and gas from previously unproductive formations. Earthquakes can be induced as part of the process to stimulate the production from tight shale formations, or by disposal of wastewater associated with stimulation and production. Here, I review recent seismic activity that may be associated with industrial activity, with a focus on the disposal of wastewater by injection in deep wells; assess the scientific understanding of induced earthquakes; and discuss the key scientific challenges to be met for assessing this hazard.

  3. Combined pre-injection wrist and ankle MRI protocol and steroid joint injections in juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kan, J.H. [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Graham, T.B. [Monroe Carell Jr. Children' s Hospital at Vanderbilt, Department of Pediatric Rheumatology, Nashville, TN (United States)

    2011-10-15

    Precise localization of affected compartments of the wrist and ankle in children with an established diagnosis of juvenile idiopathic arthritis (JIA) is clinically challenging. The purpose of this paper is to describe our experience utilizing a pre-injection MRI protocol of the wrist and ankle for localizing disease activity followed by fluoroscopically guided joint injections in children with JIA. (orig.)

  4. Quasi-stable injection channels in a wakefield accelerator

    CERN Document Server

    Wiltshire-Turkay, Mara; Pukhov, Alexander

    2016-01-01

    Particle-driven plasma-wakefield acceleration is a promising alternative to conventional electron acceleration techniques, potentially allowing electron acceleration to energies orders of magnitude higher than can currently be achieved. In this work we investigate the dependence of the energy gain on the position at which electrons are injected into the wake. Test particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the centre of the wake. The result is relevant to the planning and tuning of experiments making use of external injection.

  5. Ultrafast and Gigantic Spin Injection in Semiconductors

    Science.gov (United States)

    Battiato, M.; Held, K.

    2016-05-01

    The injection of spin currents in semiconductors is one of the big challenges of spintronics. Motivated by the ultrafast demagnetization and spin injection into metals, we propose an alternative femtosecond route based on the laser excitation of superdiffusive spin currents in a ferromagnet such as Ni. Our calculations show that even though only a fraction of the current crosses the Ni-Si interface, the laser-induced creation of strong transient electrical fields at a ferromagnet-semiconductor interface allows for the injection of chargeless spin currents with record spin polarizations of 80%. Beyond that they are pulsed on the time scale of 100 fs which opens the door for new experiments and ultrafast spintronics.

  6. Residual stress distribution in injection molded parts

    Directory of Open Access Journals (Sweden)

    P. Postawa

    2006-08-01

    Full Text Available Purpose: The paper presents the results of the investigations of influence of the amorphous polystyrene (PSprocessing on the diversity of the internal stresses observed in the injection moulded piece.Design/methodology/approach: For the tests, the standardized mould piece designed for the investigations ofthe processing shrinkage of thermoplastics materials has been used. The samples have been prepared using theDesign of Experiment (DoE theory.The state of internal stresses has been analysed by means of photoelastic method (used stress viewer equipmenton the basis of the layout and size of the isochromatics (fields with the same colour, which determine the mouldpiece’s areas where the same value for the difference of main tensions. In the article the results of investigationsof influence of 5 chosen processing parameters such as injection temperature Tw, mould temperature Tf,clamping pressure pd, cooling time tch and the injection speed vw on the changes in isochromatics layout as adeterminant for diversity of internal stresses in injection moulded pieces have been presented.Findings: The performed investigations of the influence of injection conditions on the state of internal stressesreached for injection mould pieces were to determine the parameters of injection at which the achieved state ofthe stresses in the mould piece (described by the difference of main tensions will show the lowest values.Practical implications: Effects of examinations of influence of processing conditions on residual stress ininjection molded parts (presented in the article could find practical application in polymer industry, both smalland large enterprises.Originality/value: New approach to fast estimation of value of residual stresses were present in the paper.

  7. Steroid injections - tendon, bursa, joint

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007678.htm Steroid injections - tendon, bursa, joint To use the sharing features on ... painful. It can be injected into a joint, tendon, or bursa. Description Your health care provider inserts ...

  8. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did not respond ... to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in a class of medications ...

  9. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline,

  10. Parametric Studies of Flow Separation using Air Injection

    Science.gov (United States)

    Zhang, Wei

    2004-01-01

    Boundary Layer separation causes the airfoil to stall and therefore imposes dramatic performance degradation on the airfoil. In recent years, flow separation control has been one of the active research areas in the field of aerodynamics due to its promising performance improvements on the lifting device. These active flow separation control techniques include steady and unsteady air injection as well as suction on the airfoil surface etc. This paper will be focusing on the steady and unsteady air injection on the airfoil. Although wind tunnel experiments revealed that the performance improvements on the airfoil using injection techniques, the details of how the key variables such as air injection slot geometry and air injection angle etc impact the effectiveness of flow separation control via air injection has not been studied. A parametric study of both steady and unsteady air injection active flow control will be the main objective for this summer. For steady injection, the key variables include the slot geometry, orientation, spacing, air injection velocity as well as the injection angle. For unsteady injection, the injection frequency will also be investigated. Key metrics such as lift coefficient, drag coefficient, total pressure loss and total injection mass will be used to measure the effectiveness of the control technique. A design of experiments using the Box-Behnken Design is set up in order to determine how each of the variables affects each of the key metrics. Design of experiment is used so that the number of experimental runs will be at minimum and still be able to predict which variables are the key contributors to the responses. The experiments will then be conducted in the 1ft by 1ft wind tunnel according to the design of experiment settings. The data obtained from the experiments will be imported into JMP, statistical software, to generate sets of response surface equations which represent the statistical empirical model for each of the metrics as

  11. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  12. EFFECTIVENESS OF CELLULAR INJECTION MOLDING PROCESS

    Directory of Open Access Journals (Sweden)

    Tomasz Garbacz

    2013-06-01

    Full Text Available In a study of cellular injection, molding process uses polyvinylchloride PVC. Polymers modified with introducing blowing agents into them in the Laboratory of the Department of Technologies and Materiase of Technical University of Kosice. For technological reasons, blowing agents have a form of granules. In the experiment, the content of the blowing agent (0–2,0 % by mass fed into the processed polymer was adopted as a variable factor. In the studies presented in the article, the chemical blowing agents occurring in the granulated form with a diameter of 1.2 to 1.4 mm were used. The view of the technological line for cellular injection molding and injection mold cavity with injection moldings are shown in Figure 1. The results of the determination of selected properties of injection molded parts for various polymeric materials, obtained with different content of blowing agents, are shown in Figures 4-7. Microscopic examination of cross-sectional structure of the moldings were obtained using the author's position image analysis of porous structure. Based on analysis of photographs taken (Figures 7, 8, 9 it was found that the coating containing 1.0% of blowing agents is a clearly visible solid outer layer and uniform distribution of pores and their sizes are similar.

  13. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  14. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Science.gov (United States)

    2017-01-01

    We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS) microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI) technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE) separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method. PMID:28326222

  15. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  16. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  17. The effect of injection pressure and fuel viscosity on the spray characteristics of biodiesel blends injected into an atmospheric chamber

    Energy Technology Data Exchange (ETDEWEB)

    Ghurri, Ainul; Kim, Jae Duk; Kim, Hyung Gon; Jung, Jae Youn; Song, Kyu Keun [Chonbuk National Univ., Deokjin Gu (Korea, Republic of)

    2012-09-15

    An experimental study was conducted to examine the effect of injection pressure and fuel type on the spray tip penetration length and the angle of spray injected into atmospheric chamber. The objective of the present study is to formulate empirical correlations of the spray tip penetration and the spray angle for non evaporative condition. The experiment was performed by a common rail type high pressure injector for the diesel engine at the injection pressure 40{approx}100 MPa and four different fuels (D100, BD25, BD45, and BD65). The results showed that the biodiesel content increased the spray tip penetration and decreased the spray angle. The correlation of spray tip penetration is expressed for each region before and after spray break up time in terms of injection pressure, fuel viscosity and time after start of injection. The correlation is also obtained for spray angle equation terms of injection pressure and fuel viscosity.

  18. Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance

    Directory of Open Access Journals (Sweden)

    Berteau C

    2015-11-01

    Full Text Available Cecile Berteau,1 Orchidée Filipe-Santos,1 Tao Wang,2 Humberto E Rojas,2 Corinne Granger,1 Florence Schwarzenbach1 1Becton-Dickinson Medical Pharmaceutical Systems, Le Pont de Claix, France; 2Eli Lilly and Company, Indianapolis, IN, USA Aim: The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC injection pain tolerance. Methods: The study was a single-center, comparative, randomized, crossover, Phase I study in 24 healthy adults. Each participant received six injections in the abdomen area of either a 2 or 3 mL placebo solution, with three different fluid viscosities (1, 8–10, and 15–20 cP combined with two different injection flow rates (0.02 and 0.3 mL/s. All injections were performed with 50 mL syringes and 27G, 6 mm needles. Perceived injection pain was assessed using a 100 mm visual analog scale (VAS (0 mm/no pain, 100 mm/extreme pain. The location and depth of the injected fluid was assessed through 2D ultrasound echography images. Results: Viscosity levels had significant impact on perceived injection pain (P=0.0003. Specifically, less pain was associated with high viscosity (VAS =12.6 mm than medium (VAS =16.6 mm or low (VAS =22.1 mm viscosities, with a significant difference between high and low viscosities (P=0.0002. Target injection volume of 2 or 3 mL was demonstrated to have no significant impact on perceived injection pain (P=0.89. Slow (0.02 mL/s or fast (0.30 mL/s injection rates also showed no significant impact on perceived pain during SC injection (P=0.79. In 92% of injections, the injected fluid was located exclusively in SC tissue whereas the remaining injected fluids were found located in SC and/or intradermal layers. Conclusion: The results of this study suggest that solutions of up to 3 mL and up to 15–20 cP injected into the abdomen within 10 seconds are well tolerated without pain. High

  19. On L-injective Covers

    Institute of Scientific and Technical Information of China (English)

    周德旭

    2004-01-01

    We use the class of L-injective modules to define L-injective covers, and provide the characterizations of L-injective covers by the properties of kernels of homomorphisms. We prove that the right L-noetherian right L-hereditary ring is just such that every right R-module has an L-injective cover which is monic. We also use kernels of homomorphisms to investigate L-simple L-injective covers and give some constructions ofL-simple L-iniective covers.

  20. Flow Injection Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    2004-01-01

    This chapter provides an introduction to automated chemical analysis, which essentially can be divided into two groups: batch assays, where the solution is stationary while the container is moved through a number of stations where various unit operations performed; and continuous-flow procedures,......, but it permits thr execution of novel and unique analytical procedures which are difficult or even impossible by conventional means. The performance and applicability of FIA, SI and LOV are illustrated by a series of practical examples.......This chapter provides an introduction to automated chemical analysis, which essentially can be divided into two groups: batch assays, where the solution is stationary while the container is moved through a number of stations where various unit operations performed; and continuous-flow procedures......, where the system is stationary while the solution moves through a set of conduits in which all required manipulations are performed. Emphasis is placed on flow injection analysis (FIA) and its further developments, that is, sequential injection analysis (SIA) and the Lab-on-Valve (LOV) approach. Since...

  1. Epidemiology of Injection Drug Use

    Science.gov (United States)

    Arruda, Nelson; Bruneau, Julie; Jutras-Aswad, Didier

    2016-01-01

    After more than 30 years of research, numerous studies have shown that injection drug use is associated with a wide range of adverse health outcomes such as drug overdoses, drug-related suicidal behaviours, comorbid psychiatric disorders, bloodborne pathogens and other infectious diseases, and traumas. This review explores new trends and prominent issues associated with injection drug use. The dynamic nature of injection drug use is underlined by examining its recent trends and changing patterns in Canada and other “high-income countries.” Three research topics that could further contribute to the development of comprehensive prevention and intervention strategies aimed at people who inject drugs are also discussed: risk behaviours associated with the injection of prescription opioids, binge injection drug use, and mental health problems as determinants of injection risk behaviours. PMID:27254088

  2. Clinical Experience With Acupoint Injection Combined With Packet Treatment of Hand Eczema%手部湿疹采用穴位注射联合封包治疗的临床体会

    Institute of Scientific and Technical Information of China (English)

    贾红玲

    2015-01-01

    目的:研究采用穴位注射联合封包治疗手部湿疹的疗效。方法选取我院收治的98例手部湿疹患者,随机分为对照组与观察组各49例。对照组单纯使用封包进行治疗,观察组在此基础上增加穴位注射进行联合治疗。结果观察组治疗后EASI分数下降情况明显高于对照组;观察组治疗总有效率明显高于对照组。结论运用穴位注射联合封包治疗手部湿疹的效果非常显著。%Objective To explore the effect of acupoint injection combined with packet treatment of hand eczema.Methods We selected 98 cases of hand eczema patients in our hospital, randomly divided into control group and observation group (49 cases in each group). The control group were treated using packet treatment, and the observation group were treated using acupoint injection combined with packet treatment.Results After treatment, the EASI scores of observation group decreased signiifcantly than those of the control group, the observation group total effective rate was signiifcantly higher than that in control group.Conclusion Hand eczema treated by acupoint injection and wrap therapy is very signiifcant.

  3. Experience on lumbar cistern tube drainage and intrathecal injection in the treatment of intracranial infection%腰大池置管引流加鞘内注射治疗颅内感染的体会

    Institute of Scientific and Technical Information of China (English)

    阿扎提; 郑鹏; 刘德全

    2014-01-01

    目的:探讨腰大池置管持续引流结合鞘内注射治疗颅脑外伤及开颅术后所致颅内感染的效果。方法:2009年5月-2014年5月颅脑外伤及开颅手术后颅内感染患者7例,应用腰大池置管持续外引流结合鞘内注射治疗。观察其疗效。结果:引流7~12 d,临床治愈6例,1例并发全脑室炎死亡。结论:颅脑外伤及开颅术后出现颅内感染的患者在全身应用敏感抗生素的前提下可采用腰大池置管持续外引流结合鞘内注射,该方法简便、安全、疗效肯定。%Objective:To investigate the therapeutic effect of lumbar cistern tube drainage and intrathecal injection in the treatment of intracranial infection caused by craniocerebral trauma and craniotomy.Methods:7 cases of intracranial infection caused by craniocerebral trauma and craniotomy were selected from May 2009 to May 2014.They were treated with lumbar cistern tube drainage and intrathecal injection.Observe the effect.Results:They were drainaged for 7~12 days.6 cases were cured.1 case complicated with full ventriculitis death.Conclusion:Patients with intracranial infection caused by craniocerebral trauma and craniotomy can be given lumbar cistern tube drainage and intrathecal injection under the premise of systemic application of sensitive antibiotic.This method is simple,safety and efficacy.

  4. Clinical experience of Xuebijing injection in treatment of acute pancreatitis 36 cases%血必净治疗急性胰腺炎36例临床研究

    Institute of Scientific and Technical Information of China (English)

    马超

    2011-01-01

    目的 探讨血必净注射液对急性胰腺炎患者的治疗效果.方法 将82例急性胰腺炎患者随机分为血必净治疗组和常规治疗组,常规治疗组接受改善胰周循环、抑酸、抑酶、抗炎治疗,血必净组在上述常规治疗基础上+血必净注射液40ml静点,1次/d.监测两组患者体征缓解时间、血尿淀粉酶变化情况.结果 两组体征缓解时间上无明显差异(P>0.05),血、尿淀粉酶变化有统计学意义(P>0.05).结论 血必净注射液能有效减轻急性胰腺炎症状,保护脏器功能.%Objective To discuss the treatment effect of Xuebijing injection on patients with acute pancreatits. Methods Totally 36 caces of patients with acute pancreatits were divided into two groups: Xuebijing treatment group and routine treatment group. Routine group was given improving pancreatic circulation, acid - suppressing, inhibiting enzymes, anti - inflammatory treatment. On the basis of this, Xuebijing treatment group was added Xuebijing injection 40ml once per day. Monitor the signs relief time and the change of amylase in blood and urine of the two groups. Results The signs relief time has no significant difference between two groups ( P >0. 05) ,the change of amylase in blood and urine has statistically significance ( P > 0. 05). Conclusions Xuebijing injection can effectively mitigate the signs of acute pancreatits, protect organ functions.

  5. 10 Cases of Nursing Experience of Dexamethasone Injection Treatment of Venous Catheterization Skin Allergy%地塞米松注射液治疗静脉置管皮肤过敏10例护理体会

    Institute of Scientific and Technical Information of China (English)

    高凌云

    2014-01-01

    Objective:To explore the deep venous catheter in PICC or al ergic reaction to the skin care ef ect of dexamethasone injection. Methods: from 2012 October to 2013 September in our hospital in 10 cases of local skin al ergy patients using dexamethasone injection coated and strengthen. The papula, blister patients: general y do not use alcohol wipe can be used for the first time, saline local sebum clean, with 0.5% iodophor disinfectant to be dried, coated with dexamethasone injection, to avoid the at ention of bubble film, IV3000 film can be pruned, increase the bandage times, general 2-3 day. Results: the use of dexamethasone, patients with a local al ergic skin, obviously relieve among papules, erythema, cure. No cases of lead to extubation due to local skin al ergic reaction. Conclusion: Dexamethasone Injection in the treatment of catheter after the skin has a good curative ef ect, is worth the clinical promotion.%目的:探讨地塞米松注射液在PICC或深静脉置管局部皮肤过敏护理效果。方法选取2012年10月~2013年9月我院对10例置管局部皮肤过敏患者使用地塞米松注射液外涂并加强换药。对丘疹、水疱患者:一般不使用酒精首次擦拭,可选用生理盐水进行局部皮脂清洁,再用0.5%碘伏常规消毒待干,外涂地塞米松注射液,贴膜时注意避开水泡,可修剪IV3000贴膜,增加换药次数,一般1次/2~3d。结果使用地塞米松后,患者局部过敏皮肤风疹团、丘疹明显缓解,红斑消退,达到治愈。无1例因局部皮肤过敏反应导致拔管。结论地塞米松注射液治疗置管后皮肤过敏有较好的疗效,值得临床推广。

  6. Clinical Experience of Acanthopanax Senticosus Injection in the Treatment of 60 Cases of Insomnia%刺五加注射液治疗失眠症60例临床体会

    Institute of Scientific and Technical Information of China (English)

    蒋琴; 祝红

    2011-01-01

    Objective To observe the clinical efficacy of Acanthopanax senticosus injection in the treatment of insomnia. Methods 60 insomnia cases were randomly divided into two groups: treatment group and control group (30 cases in each' group) . Patients in the treatment group were given A. Senticosus injection while thoese in the control group were given Glu injection. The curative effect, score of Pittsburgh Sleep Quality Index (PSQI) , Athens sleep quality score and adverse reactions were compared between the two groups. Results The total effective rate of treatment group was 76.67% and that of control group was 30% , there was significant difference between the two groups (P<0.05). There were significant improvement in the PSQI scores in both groups (P<0.05) and there was a significant difference between the two groups (P<0.05). No serious adverse reactions were found in both groups. Conclusion A. Senticosus injection is effective in the treatment of insomnia.%目的 观察刺五加注射液治疗失眠症的临床疗效.方法 将60例失眠患者随机分为治疗组和对照组各30例,治疗组采用刺五加注射液治疗,对照组采用5%葡萄糖注射液治疗,比较两组临床疗效、匹兹堡睡眠质量指数评分、Athens睡眠量表评分和不良反应.结果 治疗组总有效率为76.67%,对照组为30%,两组比较差异有统计学意义(P<0.05);两组匹兹堡睡眠质量指数评分治疗后较治疗前明显降低(P<0.05),两组间比较差异有统计学意义(P<0.05).两组均未见严重不良反应发生.结论 刺五加注射液治疗失眠症疗效确切.

  7. Young people at risk of transitioning to injecting drug use in Sydney, Australia: social disadvantage and other correlates of higher levels of exposure to injecting.

    Science.gov (United States)

    Lea, Toby; Bryant, Joanne; Ellard, Jeanne; Howard, John; Treloar, Carla

    2015-03-01

    While numerous studies have examined characteristics of young people who have recently initiated injecting, little attention has focused on young people who may be at high risk of transitioning to injecting. This study sought to examine the extent that socially disadvantaged young people were exposed to injecting, determine their level of hepatitis C (HCV) knowledge and identify correlates of higher injecting exposure. A cross-sectional survey was administered to 210 young people in 2010-2011 who were exposed to injecting drug use, but had not transitioned to injecting. Respondents were primarily recruited from youth services in metropolitan Sydney. Exposure to injecting in the previous 12 months was assessed with four items that examined whether close friends, romantic/sexual partners or family members/acquaintances injected drugs, and whether they were offered an injection. Most respondents had at least a few close friends who injected drugs (65%) and almost half had been offered drugs to inject in the previous 12 months (48%). It was less common for respondents to report having a partner who injects (11%). Correlates of higher injecting exposure were examined with multivariate ordinal regression. In the multivariate model, higher exposure to injecting was independently associated with the experience of abuse or violent crime [adjusted odds ratio (AOR) = 1.80] and reporting more favourable attitudes towards injecting (AOR = 0.86). Higher exposure to injecting was not independently associated with patterns or history of drug use. HCV knowledge was low to moderate and was not associated with higher exposure to injecting. That drug use was not independently associated with higher injecting exposure may suggest that exposure is shaped more by social disadvantage than by drug use patterns. Additional research is required to investigate this, using an improved measure of exposure to injecting. © 2014 John Wiley & Sons Ltd.

  8. Full Life Cycle Research at the Ketzin Pilot Site, Germany - From Safe and Successful CO2 Injection Operation to Post-Injection Monitoring and Site Closure

    Science.gov (United States)

    Liebscher, A. H.

    2016-12-01

    The Ketzin pilot site near Berlin, Germany, was initiated in 2004 as the first European onshore storage project for research and development on geological CO2 storage. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into a saline aquifer (Upper Triassic sandstone) at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section; full abandonment of this well finished in 2015 after roughly 2 years of well closure monitoring. Abandonment of the remaining 4 wells will be finished by 2017 and hand-over of liability to the competent authority is planned for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the pilot capture facility "Schwarze Pumpe" (oxyfuel power plant CO2 with purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40 - 45°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and temporal in-reservoir behaviour of the injected CO2 even for small quantities. After the cessation of CO2 injection, post-injection monitoring continued and two additional

  9. Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance.

    Science.gov (United States)

    Berteau, Cecile; Filipe-Santos, Orchidée; Wang, Tao; Rojas, Humberto E; Granger, Corinne; Schwarzenbach, Florence

    2015-01-01

    The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC) injection pain tolerance. The study was a single-center, comparative, randomized, crossover, Phase I study in 24 healthy adults. Each participant received six injections in the abdomen area of either a 2 or 3 mL placebo solution, with three different fluid viscosities (1, 8-10, and 15-20 cP) combined with two different injection flow rates (0.02 and 0.3 mL/s). All injections were performed with 50 mL syringes and 27G, 6 mm needles. Perceived injection pain was assessed using a 100 mm visual analog scale (VAS) (0 mm/no pain, 100 mm/extreme pain). The location and depth of the injected fluid was assessed through 2D ultrasound echography images. Viscosity levels had significant impact on perceived injection pain (P=0.0003). Specifically, less pain was associated with high viscosity (VAS =12.6 mm) than medium (VAS =16.6 mm) or low (VAS =22.1 mm) viscosities, with a significant difference between high and low viscosities (P=0.0002). Target injection volume of 2 or 3 mL was demonstrated to have no significant impact on perceived injection pain (P=0.89). Slow (0.02 mL/s) or fast (0.30 mL/s) injection rates also showed no significant impact on perceived pain during SC injection (P=0.79). In 92% of injections, the injected fluid was located exclusively in SC tissue whereas the remaining injected fluids were found located in SC and/or intradermal layers. The results of this study suggest that solutions of up to 3 mL and up to 15-20 cP injected into the abdomen within 10 seconds are well tolerated without pain. High viscosity injections were shown to be the most tolerated, whereas injection volume and flow rates did not impact perceived pain.

  10. Longitudinal Trajectories of Ketamine Use among Young Injection Drug Users

    Science.gov (United States)

    Lankenau, Stephen E.; Bloom, Jennifer Jackson; Shin, Charles

    2010-01-01

    Background Ketamine is a dissociative anesthetic that became increasing popular in the club and rave scene in the 1980s and 1990s. Reports surfaced in the late 1990s indicating that ketamine was being injected in several U.S. cities by young injection drug users (IDUs). Since all studies on ketamine injection were cross-sectional, a longitudinal study was undertaken in 2005 to determine: characteristics of young IDUs who continue to inject ketamine; frequency of ketamine injection over an extended time period; risks associated with ongoing ketamine injection; and environmental factors that impact patterns of ketamine use. Methods Young IDUs aged 16 to 29 with a history of injecting ketamine (n=101) were recruited from public locations in Los Angeles and followed during a two-year longitudinal study. A semi-structured instrument captured quantitative and qualitative data on patterns of ketamine injection and other drug use. A statistical model sorted IDUs who completed three or more interviews (n=66) into three groups based upon patterns of ketamine injection at baseline and follow-up. Qualitative analysis focused on detailed case studies within each group. Results IDUs recruited at baseline were typically in their early 20s, male, heterosexual, white, and homeless. Longitudinal injection trajectories included: “Moderates,” who injected ketamine several times per year (n=5); “Occasionals,” who injected ketamine approximately once per year (n=21); and “Abstainers,” who did not inject any ketamine during follow-up (n=40). Findings suggest that ketamine is infrequently injected compared to other drugs such as heroin, cocaine, and methamphetamine. Most IDUs who begin injecting ketamine will stop or curb use due to: negative or ambivalent experiences associated with ketamine; an inability to find the drug due to declining supply; or maturing out of injecting drugs more generally. Conclusion Reducing ketamine injection among young IDUs may best be accomplished

  11. Effects of injection pressure and injection timing to exhaust gas opacity for a conventional indirect diesel engine

    Science.gov (United States)

    Budiman, Agus; Majid, Akmal Irfan; Pambayun, Nirmala Adhi Yoga; Yuswono, Lilik Chaerul; Sukoco

    2016-06-01

    In relation to pollution control and environmental friendliness, the quality of exhaust gas from diesel engine needs to be considered. The influences of injection pressure and timing to exhaust gas opacity were investigated. A series of experiments were conducted in a one-cylinder conventional diesel engine with a naturally aspirated system and indirect injection. The default specification of injection pressure was 120 kg/cm2. To investigate the injection pressure, the engine speed was retained on 1000 rpm with pressure variations from 80 to 215 kg/cm2. On the other hand, the various injection timing (8, 10, 12, 16 degrees before TDC point and exact 18 degrees before TDC point) were used to determine their effects to exhaust gas opacity. In this case, the engine speed was varied from 1000 to 2400 rpm. The injector tester was used to measure injection pressure whereas the exhaust gas opacity was determined by the smoke meter. Those data were also statistically analyzed by product moment correlation. As the results, the injection pressure of diesel engine had a non-significant positive correlation to the exhaust gas opacity with r = 0.113 and p > 5 %. Injection pressure should be adjusted to the specification listed on the diesel engine as if it was too high or too low will lead to the higher opacity. Moreover, there was a significant positive correlation between injection timing and the exhaust gas opacity in all engine speeds.

  12. Research on the test method of using injection as an equivalent substitute for electromagnetic radiation

    Science.gov (United States)

    Pan, X. D.; Wei, G. H.; Lu, X. F.; Li, K.

    2013-03-01

    This paper presents a method to carry out high intensity radiated field (HIRF) effect experiments by using injection as an equivalent substitute for electromagnetic radiation. In allusion to typical interconnected system, the equal response voltage on the equipment cable port is regarded as an equivalent basis of injection and radiation methods. The equivalent relation formula between injected voltage and radiated field is derived theoretically. The conditions needed for extrapolating injected voltage in HIRF are confirmed, and the extrapolation method is proposed. On the basis of the above research, the electromagnetic environment effect test new method combined injection with radiation for interconnected system is summarized. The typical nonlinear interconnected system is selected as equipment under test, and the single frequency continuous wave radiation and injection effect experiments are carried out separately. The test results indicate that the relation between radiated field and injected voltage is linear, and the equivalent injected voltage used to substitute HIRF can be obtained by linear extrapolation.

  13. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  14. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes.

  15. Supersonic Jet Noise Reduction Using Flapping Injection and Pulsed Injection

    Science.gov (United States)

    Hafsteinsson, Haukur; Eriksson, Lars-Erik; Cuppoletti, Daniel; Gutmark, Ephraim; Department of Applied Mechanics, Chalmers University of Technology Team; Department of Aerospace Engineering, University of Cincinatti Team; Swedish Defence Material Administration, Sweden Team

    2013-11-01

    Aircraft are in general noisy and there is a high demand for reducing their noise levels. The jet exhaust is in most cases the main noise source of the aircraft, especially for low bypass ratio jet engines. Fluidic injection affecting the shear layer close to the nozzle exit is a promising noise reduction technique as it can be turned of while not needed and thus the negative effect on the engine performance will be minimized. In the presented work, LES is used to compare steady-state mass flow injection with steady-state mass flow flapping jet injection. The work is a direct continuation of a previous LES study on pulsed injection which showed that the pulsed injection induced pressure pulses in the jet which caused increased tonal noise in the downstream directions. The injection system considered in the presented work consists of eight evenly distributed injectors at the nozzle exit plane with a 90° injection angle relative to the flow direction. Flapping jet injection is believed to minimize the creation of these pressure pulses since it provides steady-state mass flow. This work is funded by Swedish Defense Material Administration (FMV).

  16. Theory and application of the transient injection well test

    Institute of Scientific and Technical Information of China (English)

    LIU Yuewu; CHEN Huixin; LIU Qingquan; GONG Xin; ZHANG Dawei; YAO Deliang; LI Lianxiang

    2005-01-01

    Based on the theory of the pumping well test, the transient injection well test was suggested in this paper. The design method and the scope of application are discussed in detail. The mathematical models are developed for the short-time and long-time transient injection test respectively. A double logarithm type curve matching method was introduced for analyzing the field transient injection test data. A set of methods for the transient injection test design, experiment performance and data analysis were established. Some field tests were analyzed, and the results show that the test model and method are suitable for the transient injection test and can be used to deal with the real engineering problems.

  17. Process Condition Monitoring of Micro Moulding Using a Two-plunger Micro Injection Moulding Machine

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Guerrier, Patrick

    2010-01-01

    The influence of micro injection moulding (µIM) process parameters (melt and mould temperature, piston injection speed and stoke length) on the injection pressure was investigated using Design of Experiments. Direct piston injection pressure measurements were performed and data collected using a ...... diferent processing conditions were evaluated to correlate the process parameter levels influence on the selected responses, considering both average values (for processes characterization) and standard derivations (for process robustness assessment)....

  18. The effect of blood injection for the prevention of Ethanol reflux after intrahepatic Ethanol injection in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Kook Jin; Kim, Choon Yul; Kim, Bum Soo; Hahn, Seong Tai; Lee, Jae Mun; Shinn, Kyung Sub [Catholic Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    To reduce ethanol reflux from the needle channel by injecting rat blood immediately after the injection of ethanol into rat liver. The first experiment involved 33 rat livers which were divided into four groups (three livers in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and 0.1ml saline was injected into the liver; in group 2, ethanol-Tc-99m-O{sub 4}- mixed solution (0.1ml, 0.2mCi) was injected into the liver;in groups 3 and 4, the needle channel was blocked with 0.02ml of fresh blood and old blood, respectively, after the injection of ethanol. After removing the needle, a 3cm round filter paper was laid on each injection site to absorb refluxed ethanol-T{sub c}-99m-O{sub 4}- mixed solution from the liver, and each paper was then counted by a gamma camera unit. In the second experiment, 33rats were divided into four groups (three rats in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and after exposing the left lateral lobe of the liver, 0.05 ml of saline was injected;in group 2, 0.05 ml of ethanol was injected into the livder;in groups 3 and 4 the needle channel was blocked with 0.02 ml of fresh blood and old blood, respectively, after the injection of ethanol. After ten days, peritoneal adhesions were scored macroscopically and microscopically. In the first experiment using ethanol- T{sub c}-99m-O{sub 4}- mixed solution, groups blocked with blood after the injection of mixed solution showed lower gamma counts than the group injected with mixed solution only (p-value=3D0.0002). The group blocked with old blood showed the lowest count. Macroscopical and microscopical examination of peritoneal adhesions indicated that the grade of adhesion was lower in groups blocked with blood than in the group injected with ethanol onluy (p-value=3D0.0261 and 0.0163, respectively). The above results suggest that an injection of blood after an injection of ethanol is a very effective way of preventing reflux from the liver

  19. Rapid injection of rocuronium reduces withdrawal movement on injection.

    Science.gov (United States)

    Lee, Yong Cheol; Jang, Young Ho; Kim, Jin Mo; Lee, Sang Gyu

    2009-09-01

    To test whether rapid injection of rocuronium reduces withdrawal movement on injection. Randomized, prospective trial. Operating room in a university hospital. 150 ASA physical status I and II patients aged 18 to 60 years, undergoing general anesthesia. Patients were randomized to three groups. After undergoing anesthesia induction with thiopental sodium, then 5 seconds later receiving a rubber tourniquet applied to the mid-forearm to stop intravenous (IV) flow by gravity, the pretreatment drug was injected. The tourniquet was held for 15 seconds then released, and 1.0 mg/kg of 1% rocuronium was injected IV. Group C patients (n = 50) were pretreated with 0.1 mL/kg of 0.9% NaCl and then injected with rocuronium slowly within 10 seconds. Group L patients (n = 50) were pretreated with 0.1 mL/kg of preservative-free 1% lidocaine and then injected with rocuronium slowly within 10 seconds. Group R patients (n = 50) were pretreated with 0.1 mL/kg of 0.9% NaCl and then rapidly injected with rocuronium within approximately one second (as quickly as possible). After injection of the patient with the study drug, a single anesthesiologist with no knowledge of the study protocol graded each patient's response as follows: 0 = no response; 1 = mild movement limited to the wrist only; 2 = moderate movement involving the elbow and shoulder; and 3 = severe movement involving more than one extremity. Group C had the most intense and frequent withdrawal response. The frequency and intensity of withdrawal movement was significantly less in Groups L and R than Group C. No significant difference in withdrawal response between Groups L and R was noted. Withdrawal response can be significantly reduced for rocuronium injection without lidocaine pretreatment, simply through rapid injection.

  20. MR epidurography: distribution of injectate at caudal epidural injection

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T. [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland); St Paul' s Hospital, Department of Radiology, Vancouver, BC (Canada); Kavanagh, Eoin C.; Moynagh, Michael R.; Eustace, Stephen [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland); Mater Misericordiae University Hospital, Dublin 7 (Ireland); Poynton, Ashley; Chan, Vikki O. [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland)

    2014-08-02

    To (a) evaluate the feasibility of MR epidurography (MRE) and (b) assess the distribution of injectate using two different volumes at caudal epidural steroid injection. Twenty patients who were referred with symptomatic low back pain for caudal epidural steroid injection were assigned to have either 10 ml (9/20) or 20 ml (11/20) of injectate administered. Gadolinium was included in the injection. The patients proceeded to MRI where sagittal and coronal T1-weighted fat-saturated sequences were acquired and reviewed in the mid-sagittal and right and left parasagittal views at the level of the exit foramina. Gadolinium was observed at or above the L3/4 disc level in all 11 patients who received 20 ml (100 %), compared with only five of nine patients who received 10 ml (56 %). Injectate was seen to the L4 nerve root level in all 11 patients who received 20 ml (100 %) but only four out of nine patients who received 10 ml (44 %), not even reaching the L5 nerve root level in four further of these nine patients (44 %). Overall, there was a trend to visualize gadolinium at higher levels of the epidural space with higher volumes injected. Firstly, MR epidurography is a safe technique that allows excellent visualization of the distribution of gadolinium in the epidural space following injection via the caudal hiatus. Secondly, a volume of 10 ml is unlikely to treat L5/S1 disease in almost half of patients at caudal epidural steroid injection and at least 20 ml of injectate is likely required for any medication to reach the desired level. (orig.)

  1. Prime injections and quasipolarities

    Directory of Open Access Journals (Sweden)

    Octavio Alberto Agustín-Aquino

    2014-05-01

    Full Text Available Let $p$ be a prime number. Consider the injection\\[ \\iota:\\mathbb{Z}/n\\mathbb{Z}\\to\\mathbb{Z}/pn\\mathbb{Z}:x\\mapsto px, \\]and the elements $e^{u}.v:=(u,v\\in \\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ and$e^{w}.r:=(w,r\\in \\mathbb{Z}/pn \\mathbb{Z}\\rtimes \\mathbb{Z}/pn\\mathbb{Z}^{\\times}$. Suppose that $e^{u}.v\\in\\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ is seen as an automorphism of $\\mathbb{Z}/n\\mathbb{Z}$defined by $e^{u}.v(x=vx+u$; then $e^{u}.v$ is a \\emph{quasipolarity} if it is an involution without fixed points.In this brief note we give an explicit formula for the number of quasipolarities of $\\mathbb{Z}/n\\mathbb{Z}$ interms of the prime decomposition of $n$, and we prove sufficient conditions such that $(e^{w}.r\\circ \\iota=\\iota\\circ (e^{u}.v$, where $e^{w}.r$ and $e^{u}.v$ are quasipolarities.

  2. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, Martin J.; Orr, Jr., Franklin M.

    1999-12-20

    This report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1998 - September 1998 under the third year of a three-year Department of Energy (DOE) grant on the ''Prediction of Gas Injection Performance for Heterogeneous Reservoirs''. The research effort is an integrated study of the factors affecting gas injection, from the pore scale to the field scale, and involves theoretical analysis, laboratory experiments and numerical simulation. The research is divided into four main areas: (1) Pore scale modeling of three-phase flow in porous media; (2) Laboratory experiments and analysis of factors influencing gas injection performance at the core scale with an emphasis on the fundamentals of three-phase flow; (3) Benchmark simulations of gas injection at the field scale; and (4) Development of streamline-based reservoir simulator.

  3. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline, Em

  4. Interferon Alfa-2b Injection

    Science.gov (United States)

    Interferon alfa-2b injection is used to treat a number of conditions.Interferon alfa-2b injection is used alone or in ... Hodgkin's lymphoma (NHL; a slow-growing blood cancer). Interferon alfa-2b is in a class of medications ...

  5. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  6. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline, Em

  7. An experimental investigation on hydrogen fuel injection in intake port and manifold with different EGR rates

    Directory of Open Access Journals (Sweden)

    N.Saravanan, G.Nagarajan

    2010-03-01

    Full Text Available In the present investigation hydrogen was used in a diesel engine in the dual fuel mode using diesel as an ignition source. In order to have a precise control of hydrogen flow and to avoid the backfire and pre-ignition problems hydrogen was injected into the intake system. Experiments were conducted to determine the optimized injection timing, injection duration and injection quantity of the fuel in manifold and port injected hydrogen-operated engine using diesel as ignition source for hydrogen operation. From the results it was observed that in manifold injection technique the optimized condition was start of injection at gas exchange top dead centre (GTDC with injection duration of 30o crank angle (CA with hydrogen flow rate of 7.5 litres/min. In port injection technique, the optimized condition was start of injection at 5o before gas exchange top dead centre (5o BGTDC with injection duration of 30o CA with hydrogen flow rate of 7.5 litres/min. With the above optimized timings of port and manifold injection it was observed that brake thermal efficiency in port injection increases by 13 % and 16 % in manifold injection at 75 % load. However at full load the brake thermal efficiency decreases by 1 % in port injection and 8 % in manifold injection. A reduction in NOX emission by 4 times is observed in port injection and 7 times in manifold injection at full load. At 75 % load the NOX emission reduces by 3 times in both port injection and manifold injection. Smoke emission increases with increase in EGR percentage. The smoke increases by 36 % at full load in port injection and by 44 % in manifold injection. At 75 % load the smoke emission reduces by 13 % in port injection and 9 % in manifold injection. In both the port injection and manifold injection ignition delay was 12o or 1.33 ms while for diesel it was 11o or 1.22 ms. Port injection system with diesel as ignition source operates smoothly and shows improved performance and emit lesser

  8. Zinc injection in German PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Stellwag, B. [Framatome ANP GmbH, Erlangen (Germany); Juergensen, M. [Kernkraftwerk Obrigheim GmbH (Germany); Wolter, D. [RWE Power AG, Kraftwerk Biblis (Germany)

    2002-07-01

    Zinc injection for further reduction of radiation fields was introduced at Unit B of Biblis Nuclear Power Station in September 1996 and at Obrigheim Nuclear Power Station in February 1998. Zinc injection is still being implemented today at these plants. This paper gives an overview of the experience acquired with the method, including the annual refueling outages in the year 2001. The main topic addressed by the paper is the evolution of dose rates at the primary system and work-related doses since introduction of the method. Reductions in high dose rate areas have meanwhile achieved values of 40 to 50%. Annual collective doses per man-hour spent in the controlled access area of the plant as well as personal doses for specific activities are also decreasing. (authors)

  9. Simulation of the injection moulding process

    Science.gov (United States)

    Hu, J.; Christensen, T.

    1993-12-01

    Simulation of the injection molding process is a helpful way for the engineers who work with plastics processing. By simulation, they will get some important parameters which sometimes are highly necessary for the mold design and processing. Thus, the engineers will save much time to do experiments for the parameters. Two simulation programs are used in this report, namely CADMOULD and CADMOULD MEFISTO which are designed by Institut fur Kunststoffverarbeitung (IKV) in Aachen, W. Germany. CADMOULD works with 2-D geometry and is specialized for rheological, thermal and mechanical calculation. It is installed on a personal computer, while CADMOULD MEFISTO works in 3-D and is installed on a VAX 8530 computer at SINTEF. A PC version of this program is also available. This report deals with CADMOULD and CADMOULD MEFISTO. The construction of flow lines, balancing of sprue system, the optimizing of injection time, and gate(s) optimizing are mainly included.

  10. Design and validation of a simulator for equine joint injections.

    Science.gov (United States)

    Fox, Victoria; Sinclair, Charlotte; Bolt, David M; Lowe, John; Weller, Renate

    2013-01-01

    Joint injections are commonly used in equine practice for diagnosis and treatment of joint disorders. Performing joint injections is hence an essential skill for equine practitioners. However, opportunities for veterinary students to practice this skill are often scarce in veterinary curricula. The aim of this study was to design and validate an equine joint injection simulator. We hypothesized that the simulator will enhance student ability and confidence in performing joint injections. The simulator was constructed around an equine forelimb skeleton with soft tissues rebuilt using building foam and rubber bands. An electrical circuit including a buzzer, a battery, wire wool in the joints, and a hypodermic needle at the end of the cable was incorporated. If the students placed the needle into the joint correctly, instant auditory feedback was provided by the buzzer. To validate the simulator, 45 veterinary students were allocated to three groups: cadaver limb, textbook, or simulator. Students' ability to perform joint injections was tested and students' opinions were evaluated with a questionnaire. The proportion of students performing a metacarpophalangeal (MCP) joint injection correctly was significantly higher in the cadaver (93%) and simulator (76%) groups compared to the textbook group (50%). There was no significant difference between groups for performing a distal interphalangeal (DIP) joint injection correctly. Students rated the learning experience with the cadaver and simulator group high and with the textbook group low. The joint injection simulator represents an affordable teaching aid that allows students to repeatedly practice this skill in their own time with immediate feedback.

  11. Giant tunnel-electron injection in nitrogen-doped graphene

    DEFF Research Database (Denmark)

    Lagoute, Jerome; Joucken, Frederic; Repain, Vincent

    2015-01-01

    Scanning tunneling microscopy experiments have been performed to measure the local electron injection in nitrogen-doped graphene on SiC(000) and were successfully compared to ab initio calculations. In graphene, a gaplike feature is measured around the Fermi level due to a phonon-mediated tunneling...... and at carbon sites. Nitrogen doping can therefore be proposed as a way to improve tunnel-electron injection in graphene....

  12. Technical tips for collagenase injection treatment for Dupuytren contracture.

    Science.gov (United States)

    Meals, Roy A; Hentz, Vincent R

    2014-06-01

    We describe technical tips for injecting collagenase into Dupuytren cords based on experience acquired during the prerelease Food and Drug Administration clinical trials and with subsequent clinical practice. These tips include techniques for extracting the reconstituted enzyme efficiently from the vial, injecting the cord(s) with increased safety to the tendons, and anesthetizing the hand before manipulation. The tips are intended to supplement but by no means replace the manufacturer's prescribing information and training video.

  13. Tracer injection techniques in flowing surface water

    Science.gov (United States)

    Wörman, A.

    2009-04-01

    Residence time distributions for flowing water and reactive matter are commonly used integrated properties of the transport process for determining technical issues of water resource management and in eco-hydrological science. Two general issues for tracer techniques are that the concentration-vs-time relation following a tracer injection (the breakthrough curve) gives unique transport information in different parts of the curve and separation of hydromechanical and reactive mechanisms often require simultaneous tracer injections. This presentation discusses evaluation methods for simultaneous tracer injections based on examples of tracer experiments in small rivers, streams and wetlands. Tritiated water is used as a practically inert substance to reflect the actual hydrodynamics, but other involved tracers are Cr(III)-51, P-32 and N-15. Hydromechanical, in-stream dispersion is reflected as a symmetrical spreading of the spatial concentration distribution. This requires that the transport distance over water depth is larger than about five times the flow Peclet number. Transversal retention of both inert and reactive solutes is reflected in terms of the tail of the breakthrough curve. Especially, reactive solutes can have a substantial magnification of the tailing behaviour depending on reaction rates or partitioning coefficients. To accurately discriminate between the effects of reactions and hydromechanical mixing its is relevant to use simultaneous injections of inert and reactive tracers with a sequential or integrated evaluation procedure. As an example, the slope of the P-32 tailing is consistently smaller than that of a simultaneous tritium injection in Ekeby wetland, Eskilstuna. The same applies to N-15 injected in the same experiment, but nitrogen is affected also by a systematic loss due to denitrification. Uptake in stream-bed sediments can be caused by a pumping effect arising when a variable pressure field is created on the stream bottom due to bed

  14. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  15. Sensor for Injection Rate Measurements

    Directory of Open Access Journals (Sweden)

    Milan Marcic

    2006-10-01

    Full Text Available A vast majority of the medium and high speed Diesel engines are equipped withmulti-hole injection nozzles nowadays. Inaccuracies in workmanship and changinghydraulic conditions in the nozzles result in differences in injection rates between individualinjection nozzle holes. The new deformational measuring method described in the paperallows injection rate measurement in each injection nozzle hole. The differences in injectionrates lead to uneven thermal loads of Diesel engine combustion chambers. All today knownmeasuring method, such as Bosch and Zeuch give accurate results of the injection rate indiesel single-hole nozzles. With multihole nozzles they tell us nothing about possibledifferences in injection rates between individual holes of the nozzle. At deformationalmeasuring method, the criterion of the injected fuel is expressed by the deformation ofmembrane occurring due to the collision of the pressure wave against the membrane. Thepressure wave is generated by the injection of the fuel into the measuring space. For eachhole of the nozzle the measuring device must have a measuring space of its own into whichfuel is injected as well as its measuring membrane and its own fuel outlet. Duringmeasurements procedure the measuring space must be filled with fuel to maintain anoverpressure of 5 kPa. Fuel escaping from the measuring device is conducted into thegraduated cylinders for measuring the volumetric flow through each hole of the nozzle.Themembrane deformation is assessed by strain gauges. They are glued to the membrane andforming the full Wheatstone’s bridge. We devoted special attention to the membrane shapeand temperature compensation of the strain gauges.

  16. LHC injection and dump protection

    CERN Document Server

    Bartmann, W; Bracco, C; Goddard, B; Kain, V; Rossi, A; Wollmann, D

    2010-01-01

    The machine protection against fast failures including injection or dump kickers relies on fixed and movable devices. Results will be shown from the low-intensity beam commissioning of the moveable injection protection devices in the SPS to LHC transfer lines and downstream of the LHC injection kickers, and of the LHC dump protection elements in IR6. This paper is almost exclusively focussing on the issues arising during the 2009 commissioning. The implications of these results and a commissioning status report with the planning for 2010 will be addressed.

  17. Financial methods for waterflooding injectate design

    Energy Technology Data Exchange (ETDEWEB)

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

  18. Peginterferon Beta-1a Injection

    Science.gov (United States)

    ... lower legs hoarseness difficulty breathing or swallowing redness, warmth, swelling, pain, or infection in the place where you injected the medication that does not heal within a few days red or bloody stools or diarrhea stomach pain slow ...

  19. Beam Injection in Recirculator SALO

    CERN Document Server

    Guk, Ivan S; Dovbnya, Anatoly N; Kononenko, Stanislav; Peev, Fedor; Tarasenko, Alexander; Van der Wiel, Marnix

    2005-01-01

    Possible antetypes of injectors for electron recirculator SALO,* intended for nuclear-physical research, are analyzed. The plan injection of beams in recirculator is offered. Expected parameters of beams are designed.

  20. Infliximab, Infliximab-dyyb Injection

    Science.gov (United States)

    Infliximab and infliximab-dyyb injection are used to relieve the symptoms of certain autoimmune disorders (conditions in which the immune system ... has not improved when treated with other medications. Infliximab may also be used to relieve symptoms of ...

  1. Interferon Gamma-1b Injection

    Science.gov (United States)

    Interferon gamma-1b injection is used to reduce the frequency and severity of serious infections in people with ... with severe, malignant osteopetrosis (an inherited bone disease). Interferon gamma-1b is in a class of medications called ...

  2. Computational Analysis of Safety Injection Tank Performance

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadia, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine; Yoon, Ho Joon [Khalifa University of Science Technology and Research, Abu Dhabi (United Arab Emirates)

    2015-10-15

    The APR 1400 is a large pressurized water reactor (PWR). Just like many other water reactors, it has an emergency core cooling system (ECCS). One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling. The SIT of APR1400 was analyzed using MARS and CFD. CFD calculation was executed first to obtain the form loss factor. Using the two form loss factors from the vendor and calculation, calculation using MARS was performed to compare with experiment. The accumulator model in MARS was quite accurate in predicting the water level. The pipe model showed some difference with the experimental data in the water level.

  3. Inverse spin Hall effect by spin injection

    Science.gov (United States)

    Liu, S. Y.; Horing, Norman J. M.; Lei, X. L.

    2007-09-01

    Motivated by a recent experiment [S. O. Valenzuela and M. Tinkham, Nature (London) 442, 176 (2006)], the authors present a quantitative microscopic theory to investigate the inverse spin-Hall effect with spin injection into aluminum considering both intrinsic and extrinsic spin-orbit couplings using the orthogonalized-plane-wave method. Their theoretical results are in good agreement with the experimental data. It is also clear that the magnitude of the anomalous Hall resistivity is mainly due to contributions from extrinsic skew scattering.

  4. Injectable Drug Eluting Elastomeric Polymer: A Novel Submucosal Injection Material

    Science.gov (United States)

    Tran, Richard T.; Palmer, Michael; Tang, Shou-Jiang; Abell, Thomas L.; Yang, Jian

    2011-01-01

    Background Biodegradable hydrogels can deliver therapeutic payloads with great potentials in endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) to yield improvements in efficacy and foster mucosal regeneration. Objective To assess the efficacy of an injectable drug eluting elastomeric polymer (iDEEP) as a submucosal injection material. Design Comparative study among 3 different solutions using material characterization tests, ex vivo and in vivo porcine models. Setting Academic hospital. Interventions 30 gastric submucosal cushions were achieved with saline (0.9%), sodium hyaluronate (0.4%), and iDEEP (n = 10) in ex vivo porcine stomachs. Four porcine gastric submucosal cushions were then performed in vivo using iDEEP. Main outcome measurements Maximum injection pressure, Rebamipide release rate, submucosal elevation duration, and assessment of in vivo efficacy by en bloc resection. Results No significant difference in injection pressures between iDEEP (28.9 ± 0.3 PSI) and sodium hyaluronate (29.5 ± 0.4 PSI, P > .05) was observed. iDEEP gels displayed a controlled release of Rebamipide up to 2 weeks in vitro. The elevation height of iDEEP (5.7 ± 0.5 mm) was higher than saline (2.8 ± 0.2 mm, P < .01) and SH (4.2 ± 0.2 mm, P < .05). All EMR procedures were successfully performed after injection of iDEEP, and a large gel cushion was noted after the resection procedure. Limitations Benchtop, ex vivo, and non-survival pig study. Conclusions A novel injection solution was evaluated for endoscopic resection. These results suggest that iDEEP may provide a significant step towards the realization of an ideal EMR and ESD injection material. PMID:22301346

  5. Subcutaneous injection-induced cellulites.

    Science.gov (United States)

    Cheng, Kao-Chi; Huang, Po-Tsung; Liu, Chiu-Shong; Lin, Wen-Yuan

    2017-06-01

    In the hospice ward where patients are in the terminal stages of cancer, it is common practice to give them a subcutaneous injection of pain relievers to reduce their pain and make them more comfortable. Most of these patients are elderly and have low blood pressure or poor veins, which often makes it difficult to inject them because of the calcification at previous injection sites. Thus, subcutaneous injections are a convenient way to maintain analgesia and patient comfort. Our patient, a 73-year-old aboriginal woman, was diagnosed with gastric adenocarcinoma and peritoneal carcinomatosis in March, 2004. While she was in the inpatient hospice ward, a subcutaneous injection site became infected and localized cellulitis developed. The patient's quality of life began to decline and her hospice stay was lengthened due to these complications. This case is offered as a reference case of subcutaneous injection complications encountered by elderly patients in hospice care. © Author(s) 2017. This article is published with open access by China Medical University.

  6. Intravenous injections in neonatal mice.

    Science.gov (United States)

    Gombash Lampe, Sara E; Kaspar, Brian K; Foust, Kevin D

    2014-11-11

    Intravenous injection is a clinically applicable manner to deliver therapeutics. For adult rodents and larger animals, intravenous injections are technically feasible and routine. However, some mouse models can have early onset of disease with a rapid progression that makes administration of potential therapies difficult. The temporal (or facial) vein is just anterior to the ear bud in mice and is clearly visible for the first two days after birth on either side of the head using a dissecting microscope. During this window, the temporal vein can be injected with volumes up to 50 μl. The injection is safe and well tolerated by both the pups and the dams. A typical injection procedure is completed within 1-2 min, after which the pup is returned to the home cage. By the third postnatal day the vein is difficult to visualize and the injection procedure becomes technically unreliable. This technique has been used for delivery of adeno-associated virus (AAV) vectors, which in turn can provide almost body-wide, stable transgene expression for the life of the animal depending on the viral serotype chosen.

  7. Microbial Response to Carbon Dioxide Injection in a Shallow Aquifer

    Science.gov (United States)

    Rook, A.; Faehndrich, D.; O'Mullan, G.; Mailloux, B.; Matter, J.; Stute, M.; Goldberg, D.

    2007-12-01

    Extensive research is underway to investigate the geophysical and geochemical dynamics of subsurface carbon sequestration, but there has been only theoretical consideration of the microbial response. Microbial dynamics are capable of altering the range and rates of geochemical reactions in the subsurface. The goal of this field experiment is to link geochemical changes due to CO2 injection to alterations in the microbial community and to provide an initial characterization of the microbial response. A seven week push-pull experiment was conducted at the Lamont-Doherty Earth Observatory Test Well. 200L of groundwater was extracted, bubbled with carbon dioxide, augmented with a bromide tracer, and injected to 230m depth below ground surface. The hydraulically isolated injection zone marked the contact area between dolerite sill and sedimentary rock. Samples were taken on a weekly basis. Geochemically, a drop in pH from 9.4 to 4.5 at injection was coupled with a release of Fe2+ from the formation. As neutralization and mixing caused pH to return toward background levels, Fe2+ concentrations decreased. The aquifer remained anoxic throughout the experiment. DNA was successfully extracted and the gene encoding 16S ribosomal RNA was amplified from all samples with the exception of the injection fluid. Sequencing from clone libraries and tRFLP analyses were used to characterize microbial dynamics during the seven week study. Whereas the number of microbial groups detected remained relatively constant over the course of the experiment, changes were observed in both the dominant microbes phylogenetic identity and relative abundance. Methane concentrations increased from background levels (below 50 nM) to 4.2 nM after injection, but initial attempts to amplify archaeal and methanogen-specific genes were unsuccessful, bringing into question the presence of a significant methanogenic population. These results confirm that there is a microbial response to carbon dioxide

  8. New injection recommendations for patients with diabetes

    NARCIS (Netherlands)

    Frid, A.; Hirsch, L.; Gaspar, R.; Hicks, D.; Kreugel, G.; Liersch, J.; Letondeur, C.; Sauvanet, J. P.; Tubiana-Rufi, N.; Strauss, K.

    2010-01-01

    Aim: Injections administered by patients are one of the mainstays of diabetes management. Proper injection technique is vital to avoiding intramuscular injections, ensuring appropriate delivery to the subcutaneous tissues and avoiding common complications such as lipohypertrophy. Yet few formal guid

  9. New injection recommendations for patients with diabetes

    NARCIS (Netherlands)

    Frid, A.; Hirsch, L.; Gaspar, R.; Hicks, D.; Kreugel, G.; Liersch, J.; Letondeur, C.; Sauvanet, J. P.; Tubiana-Rufi, N.; Strauss, K.

    Aim: Injections administered by patients are one of the mainstays of diabetes management. Proper injection technique is vital to avoiding intramuscular injections, ensuring appropriate delivery to the subcutaneous tissues and avoiding common complications such as lipohypertrophy. Yet few formal

  10. Performance of the Charge Injection Capability of Suzaku XIS

    CERN Document Server

    Nakajima, H; Matsumoto, H; Tsuru, T G; Koyama, K; Tsunemi, H; Hayashida, K; Torii, K; Namiki, M; Katsuda, S; Shoji, M; Matsuura, D; Miyauchi, T; Dotani, T; Ozaki, M; Murakami, H; Bautz, M W; Kissel, S E; LaMarr, B; Prigozhin, G Y

    2007-01-01

    A charge injection technique is applied to the X-ray CCD camera, XIS (X-ray Imaging Spectrometer) onboard Suzaku. The charge transfer inefficiency (CTI) in each CCD column (vertical transfer channel) is measured by the injection of charge packets into a transfer channel and subsequent readout. This paper reports the performances of the charge injection capability based on the ground experiments using a radiation damaged device, and in-orbit measurements of the XIS. The ground experiments show that charges are stably injected with the dispersion of 91eV in FWHM in a specific column for the charges equivalent to the X-ray energy of 5.1keV. This dispersion width is significantly smaller than that of the X-ray events of 113eV (FWHM) at approximately the same energy. The amount of charge loss during transfer in a specific column, which is measured with the charge injection capability, is consistent with that measured with the calibration source. These results indicate that the charge injection technique can accura...

  11. Spin injection into a two-dimensional electron gas using inter-digital-ferromagnetic contacts

    DEFF Research Database (Denmark)

    Hu, C.M.; Nitta, J.; Jensen, Ane;

    2002-01-01

    We present a model that describes the spin injection across a single interface with two electrodes. The spin-injection rate across a typical hybrid junction made of ferromagnet (FM) and a two-dimensional electron gas (2DEG) is found at the percentage level. We perforin spin-injection-detection ex......-injection-detection experiment on devices with two ferromagnetic contacts on a 2DEG confined in an InAs quantum well. A spin-injection rate of 4.5% is estimated from the measured magnetoresistance....

  12. Distribution of Bacteria Injected in Body of Giant Black Shrimp, Penaeus Monodon

    Institute of Scientific and Technical Information of China (English)

    GUO Zhixun(郭志勋); Karin van de Braak; Magriet Botterbloom

    2004-01-01

    Distribution of injected Vibrio anguillarum in body of Penaeus monodon was studied with immunohistochemical method. Bacteria could be detected throughout the experiment in some individuals; however in lymphoid tissue, gill, heart and haemolymph of all vibrio injected shrimp, the bacteria could be observed only 5 min after injection. The bacteria density in haemolymph, haemolymph of the hepatopancreas and gills decreased with time. In the lymphoid organ and heart, the bacteria density was the highest 48 h after injection, then decreased. Nodules could be formed in the heart, lymphoid organ and injection site.

  13. Injection through fractures

    Energy Technology Data Exchange (ETDEWEB)

    Johns, R.A.

    1987-05-01

    Tracer tests are conducted in geothermal reservoirs as an aid in forecasting thermal breakthrough of reinjection water. To interpret tracer tests, mathematical models have been developed based on the various transport mechanisms in these highly fractured reservoirs. These tracer flow models have been applied to interpret field tests. The resulting matches between the model and field data were excellent and the model parameters were used to estimate reservoir properties. However, model fitting is an indirect process and the model's ability to estimate reservoir properties cannot be judged solely on the quality of the match between field data and model predictions. The model's accuracy in determining reservoir characteristics must be independently verified in a closely controlled environment. In this study, the closely controlled laboratory environment was chosen to test the validity and accuracy of tracer flow models developed specifically for flow in fractured rocks. The laboratory tracer tests were performed by flowing potassium iodide (KI) through artificially fractured core samples. The tracer test results were then analyzed with several models to determine which best fit the measured data. A Matrix Diffusion model was found to provide the best match of the tracer experiments. The core properties, as estimated by the Matrix Diffusion model parameters generated from the indirect matching process, were then determined. These calculated core parameters were compared to the measured core properties and were found to be in agreement. This verifies the use of the Matrix Diffusion flow model in estimating fracture widths from tracer tests.

  14. Injectable bioactive calcium-magnesium phosphate cement for bone regeneration.

    Science.gov (United States)

    Wu, Fan; Su, Jiacan; Wei, Jie; Guo, Han; Liu, Changsheng

    2008-12-01

    Novel injectable and degradable calcium-magnesium phosphate cement (CMPC) with rapid-setting characteristic was developed by the introduction of magnesium phosphate cement (MPC) into calcium phosphate cement (CPC). The calcium-magnesium phosphate cement prepared under the optimum P/L ratio exhibited good injectability and desired workability. It could set within 10 min at 37 degrees C in 100% relative humidity and the compressive strength could reach 47 MPa after setting for 48 h, indicating that the prepared cement has relatively high initial mechanical strength. The results of in vitro degradation experiments demonstrated the good degradability of the injectable CMPC, and its degradation rate occurred significantly faster than that of pure CPC in simulated body fluid (SBF) solution. It can be concluded that the novel injectable calcium-magnesium phosphate cement is highly promising for a wide variety of clinical applications, especially for the development of minimally invasive techniques.

  15. Study of fault injection system based on software

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A software fault injection system SFIS is designed, which consists of the target system plus a fault injector, fault library, workload, data collector, and data analyzer. A serial communication mechanism is adopted to simulate the factual work environment. Then a fault model is built for single particle event, which can be denoted as FM = (FL, FT). FL stands for fault location, and FT stands for fault type. The fault model supports three temporal faults: transient, intermittent, and permanent. During the experiments implemented by SFIS,the software interruption method is adopted to inject transient faults, and step trace method is adopted to inject permanent faults into the target system. The experiment results indicate that for the injected transient code segment faults, 2.8% of them do not affect the program output, 80.1% of them are detected by the built-in error detection in the system, and 17.1% of them are not detected by fault detection mechanism. The experiment results verify the validity of the fault injection method.

  16. Compact toroid injection into C-2U

    Science.gov (United States)

    Roche, Thomas; Gota, H.; Garate, E.; Asai, T.; Matsumoto, T.; Sekiguchi, J.; Putvinski, S.; Allfrey, I.; Beall, M.; Cordero, M.; Granstedt, E.; Kinley, J.; Morehouse, M.; Sheftman, D.; Valentine, T.; Waggoner, W.; the TAE Team

    2015-11-01

    Sustainment of an advanced neutral beam-driven FRC for a period in excess of 5 ms is the primary goal of the C-2U machine at Tri Alpha Energy. In addition, a criteria for long-term global sustainment of any magnetically confined fusion reactor is particle refueling. To this end, a magnetized coaxial plasma-gun has been developed. Compact toroids (CT) are to be injected perpendicular to the axial magnetic field of C-2U. To simulate this environment, an experimental test-stand has been constructed. A transverse magnetic field of B ~ 1 kG is established (comparable to the C-2U axial field) and CTs are fired across it. As a minimal requirement, the CT must have energy density greater than that of the magnetic field it is to penetrate, i.e., 1/2 ρv2 >=B2 / 2μ0 . This criteria is easily met and indeed the CTs traverse the test-stand field. A preliminary experiment on C-2U shows the CT also capable of penetrating into FRC plasmas and refueling is observed resulting in a 20 - 30% increase in total particle number per single-pulsed CT injection. Results from test-stand and C-2U experiments will be presented.

  17. INJECTION TECHNOLOGY RESEARCH OF THE PROTECTIVE SCREEN

    Directory of Open Access Journals (Sweden)

    MENEJLYUK A. I.

    2016-12-01

    Full Text Available Formulation of the problem. This article contains information about the methods and the planning principles used in experimental research study of the injection technology of impervious screen. Today, there are ways to create impervious screens and curtains solve soil protection issues in the field impermeable layer arrangement at a shallow depth. However, for Ukraine, in the burial sites of radiation and other wastes is urgent issue of protection of underground space in places with deep impermeable layer. Classical methods can not fully solve such problems. To solve them, you need to develop innovative technology to create such a screen, which will lie authentic sole object to be protected, at the project depth. For the experiments, it is necessary to choose the most important indicator, and technological factors affecting it. This is due to the fact that the proposed technology provides for lesser known technical solutions, the use of which should ultimately result in impervious screens with desired properties. Goal. The aim of this study is the selection of technological parameters of injection, design of experiments and the selection of indicators characterizing the efficient operation of the screen. Such constructs must first have almost zero permeability. In this paper, it was of interest to study the influence of process parameters on the filtration rate of the protective screen. Conclusion. As a result of the design of experiments, the basic technological factors that have a significant effect on the studied parameters. varying levels of these factors are also identified, which in turn makes it possible to determine the optimum process parameters creating a screen that meets all the desired properties and characteristics. Based on a series of experiments it is possible to obtain optimal formulations for different types of soils.

  18. A three-dimensional laboratory steam injection model allowing in situ saturation measurements. [Comparing steam injection and steam foam injection with nitrogen and without nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Demiral, B.M.R.; Pettit, P.A.; Castanier, L.M.; Brigham, W.E.

    1992-08-01

    The CT imaging technique together with temperature and pressure measurements were used to follow the steam propagation during steam and steam foam injection experiments in a three dimensional laboratory steam injection model. The advantages and disadvantages of different geometries were examined to find out which could best represent radial and gravity override flows and also fit the dimensions of the scanning field of the CT scanner. During experiments, steam was injected continuously at a constant rate into the water saturated model and CT scans were taken at six different cross sections of the model. Pressure and temperature data were collected with time at three different levels in the model. During steam injection experiments, the saturations obtained by CT matched well with the temperature data. That is, the steam override as observed by temperature data was also clearly seen on the CT pictures. During the runs where foam was present, the saturation distributions obtained from CT pictures showed a piston like displacement. However, the temperature distributions were different depending on the type of steam foam process used. The results clearly show that the pressure/temperature data alone are not sufficient to study steam foam in the presence of non-condensible gas.

  19. INJECTION VOLUME CONTROL BY THERMAL WAY IN TRANSGENIC DNA MICRO-INJECTION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Zhang Ling; Zhang Yun; Yang Yimin; Chen Jinghua

    2004-01-01

    Nowdays there are several manual or half-automatic methods developed to drive the DNA micro-fluid of transgenic micro-injection and they often fail to control precisely the injection volume at picolitres level.Micro-size of the injector tip and viscosity of the DNA liquid also lead to dead area of volume control.An adequate way is presented utilizing temperature gradients to direct liquid flow in the pipette from the warmer to the cooler.Compared with the previous ones, this way is helpful in decreasing the dead area of controlling through decreasing the viscous rate of DNA liquid, which changes as the temperature varies.The DNA liquid is pushed by a sheer stress at the liquid-pipette interface, which emerges when viscous rate of the liquid changes.Preliminary experimenting results show the efficiency and convenience of this way in improving the system's characteristics.

  20. Effect of injection timing and injection pressure on the performance ...

    African Journals Online (AJOL)

    DR OKE

    single cylinder diesel engine fitted with conventional mechanical fuel ... on Common Rail Direct Injection (CRDI) facilities where the biodiesel can be ... Keywords: Diesel engine, Ester of Honge Oil (EHO), Common Rail Direct ..... emission of EHO was higher than those of the diesel under the same operating conditions.

  1. Direct fuel injection in spark ignition engines; Injecao direta de combustivel em motores de ignicao por centelha

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Rodrigo Fernando Estella dos; Hildebrand Junior, Leonidas; Passarini, Luis Carlos; Santos, Antonio Moreira dos; Bezerra, Adriano Carlos Nogueira [Sao Paulo Univ., Sao Carlos, SP (Brazil). Dept. de Engenharia Mecanica]. E-mail: santosrf@sc.usp.br

    2000-07-01

    This paper presents the state-of-art of the fuel direct electronic injection, specifically the Otto cycle, the present technology for feasibility of the utilization, the characteristics of the engine using this system, by comparison with systems using the indirect fuel injection, the obtained results with laboratory experiments performed in direct and indirect fuel injection and conclusions as well.

  2. On Simple-Injective Rings

    Institute of Scientific and Technical Information of China (English)

    W.K. Nicholson; Jae Keol Park; M.F. Yousif

    2002-01-01

    A ring R is called right simple-injective if every R-linear map from a right ideal of R to R with simple image can be extended to R. It is shown that a right simple-injective ring R is quasi-Frobenius if R is right Goldie with essential right socle, or R is left perfect and the right annihilator of k ∈ R is finitely generated whenever kR or Rk is simple. This extends a result of Bjork.

  3. Mastering Ninject for dependency injection

    CERN Document Server

    Baharestani, Daniel

    2013-01-01

    Mastering Ninject for Dependency Injection teaches you the most powerful concepts of Ninject in a simple and easy-to-understand format using lots of practical examples, diagrams, and illustrations.Mastering Ninject for Dependency Injection is aimed at software developers and architects who wish to create maintainable, extensible, testable, and loosely coupled applications. Since Ninject targets the .NET platform, this book is not suitable for software developers of other platforms. Being familiar with design patterns such as singleton or factory would be beneficial, but no knowledge of depende

  4. Therapeutic hip injections: Is the injection volume important?

    Energy Technology Data Exchange (ETDEWEB)

    Young, R., E-mail: russell.young@gwh.nhs.uk [Department of Radiology, Great Western Hospital, Swindon (United Kingdom); Harding, J. [Department of Radiology, University Hospital Coventry, Coventry (United Kingdom); Kingsly, A. [Department of Mathematics and Statistics, Bristol Institue of Technology, University of the West of England, Bristol (United Kingdom); Bradley, M. [Department of Radiology, Southmead Hospital, Bristol (United Kingdom)

    2012-01-15

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  5. The effect of hot water injection on sandstone permeability

    DEFF Research Database (Denmark)

    Rosenbrand, Esther; Haugwitz, Christian; Jacobsen, Peter Sally Munch;

    2014-01-01

    Seasonal energy storage can be achieved by hot water injection in geothermal sandstone aquifers. We present an analysis of literature data in combination with new short-term flow through permeability experiments in order to address physical and physico-chemical mechanisms that can alter...

  6. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, M.J.; Orr, F.M. Jr.

    2001-03-26

    This report was an integrated study of the physics and chemistry affecting gas injection, from the pore scale to the field scale, and involved theoretical analysis, laboratory experiments and numerical simulation. Specifically, advances were made on streamline-based simulation, analytical solutions to 1D compositional displacements, and modeling and experimental measures of three-phase flow.

  7. Strategies for Improving Patient Comfort During Intravitreal Injections: Results from a Survey-Based Study.

    Science.gov (United States)

    Gomez, Jessica; Koozekanani, Dara D; Feng, Alex Z; Holt, Mitchell; Drayna, Paul; Mackley, Melissa R; van Kuijk, Frederik J G M; Beardsley, Robert M; Johnston, Richard H; Terry, Joseph M; Montezuma, Sandra R

    2016-12-01

    Many ocular diseases require intravitreal injections of pharmacological agents. Optimizing patients' experiences during injections is important to ensure compliance and maintenance of quality of life. The objective of this study was to identify strategies to help alleviate discomfort during intravitreal injections. A cross-sectional study surveying 128 patients during clinic visits between 2014 and 2015 in two outpatient Retina Clinics (one academic and one private). Patients receiving an intravitreal injection(s) for any retinal disorder were given a questionnaire with 10-yes/no responses for various potential strategies. Responses were stratified by sex, age (60 years) and total number of prior injections (0-9 injections, 10-20 injections and >20 injections). A total of 128 patients were surveyed: 59 males, 41 females and 28 with no sex specified. Our results identified four favorable strategies as those receiving more than 50% "yes" votes. These included the presence of technician/staff during the procedure, the use of a neck pillow, a verbal warning before the injection and performing injections in both eyes on the same day. Other specific strategies were identified for females, younger patients and those with greatest experience. These included: females preferred having their hand held during injections (P = 0.001) and using a stress ball (P = 0.000) when compared to males. Stratifying by age, patients 30-60 years old preferred having their hand held (P = 0.008) and background music (P = 0.007). Stratifying by prior injections, patients with >20 prior injections preferred having their hand held (P = 0.001), using a stress ball (P = 0.021) and, if necessary, having bilateral injections performed the same day to improve comfort (P = 0.037). Having an extra staff member present during the injection, having a neck pillow, having a verbal warning prior to injection and having both eyes injected on the same day were indicated as favorable strategies

  8. A contoured gap coaxial plasma gun with injected plasma armature

    Science.gov (United States)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 1017 cm-3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  9. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  10. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  11. XQuery Injection Attack and Countermeasures

    Institute of Scientific and Technical Information of China (English)

    谭玉森

    2014-01-01

    As a database that allows data to be stored in XML format, XML database suffers from some similar attacks as traditional relational database does. These attacks include injection attack by XQuey function in application software. These include BaseX, eXist and MarkLogic. In order to defeat these attacks, countermeasures are proposed.

  12. Simulating Magnetized Laboratory Plasmas with Smoothed Particle Hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jeffrey N. [Univ. of California, Davis, CA (United States)

    2009-01-01

    The creation of plasmas in the laboratory continues to generate excitement in the physics community. Despite the best efforts of the intrepid plasma diagnostics community, the dynamics of these plasmas remains a difficult challenge to both the theorist and the experimentalist. This dissertation describes the simulation of strongly magnetized laboratory plasmas with Smoothed Particle Hydrodynamics (SPH), a method born of astrophysics but gaining broad support in the engineering community. We describe the mathematical formulation that best characterizes a strongly magnetized plasma under our circumstances of interest, and we review the SPH method and its application to astrophysical plasmas based on research by Phillips [1], Buerve [2], and Price and Monaghan [3]. Some modifications and extensions to this method are necessary to simulate terrestrial plasmas, such as a treatment of magnetic diffusion based on work by Brookshaw [4] and by Atluri [5]; we describe these changes as we turn our attention toward laboratory experiments. Test problems that verify the method are provided throughout the discussion. Finally, we apply our method to the compression of a magnetized plasma performed by the Compact Toroid Injection eXperiment (CTIX) [6] and show that the experimental results support our computed predictions.

  13. Fast, deep record length, time-resolved visible spectroscopy of plasmas using fiber grids

    Science.gov (United States)

    Brockington, Samuel; Case, Andrew; Cruz, Edward; Witherspoon, F. Douglas; Horton, Robert; Klauser, Ruth; Hwang, D. Q.

    2016-10-01

    HyperV Technologies is developing a fiber-coupled, deep-record-length, low-light camera head for performing high time resolution spectroscopy on visible emission from plasma events. New solid-state Silicon Photo-Multiplier (SiPM) chips are capable of single photon event detection and high speed data acquisition. By coupling the output of a spectrometer to an imaging fiber bundle connected to a bank of amplified SiPMs, time-resolved spectroscopic imagers of 100 to 1,000 pixels can be constructed. Target pixel performance is 10 Megaframes/sec with record lengths of up to 256,000 frames yielding 25.6 milliseconds of record at10 Megasamples/sec resolution. Pixel resolutions of 8 to 12 bits are pos- sible. Pixel pitch can be refined by using grids of 100 μm to 1000 μm diameter fibers. A prototype 32-pixel spectroscopic imager employing this technique was constructed and successfully tested at the University of California at Davis Compact Toroid Injection Experiment (CTIX) as a full demonstration of the concept. Experimental results will be dis-cussed, along with future plans for the Phase 2 project, and potential applications to plasma experiments . Work supported by USDOE SBIR Grant DE-SC0013801.

  14. CO2 injection along a pipeline with transient approach

    Science.gov (United States)

    Bezos, Víctor; Carrera, Jesús; Slooten, Luit Jan; Silva, Orlando; Bear, Jacob; Kitro-Belinkov, Myra

    2013-04-01

    CO2 geological sequestration involves several processes. One of the more relevant of these processes is the CO2 injection along a pipeline, because it links the capture and transport of CO2 with its deep geological storage. The knowledge of the CO2 behavior within injection and monitoring wells is essential for designing efficient CO2 storage strategies. In particular, a thorough modeling and simulation of CO2 flow through the injection pipe is required to define operational protocols and to design the surface CO2 conditioning facilities. Much work has been performed on modeling the steady state multiphase flow in wellbores during CO2 injection. However, relevant problems, including the displacement of the initial brine in the injection well, or the upwards flow of CO2 during a push-pull test, require the modeling of transient conditions, which is the goal of the present work. Here, we present the governing equations and preliminary results for the modeling of dynamic non isothermal CO2 flow through an injection well, including displacement of the initial brine. The model considers continuity, momentum and energy equations, together with equations of state and some thermodynamic relations. These equations are solved using the simulation framework "Proost", which implements the finite element method. The code is verified by comparison with a steady-state solver for a range of surface injection conditions. The results obtained show pressure, velocity and temperature evolution, which allows quantifying the phase changes that gradually experiment the CO2 through the injection pipe. We find the surface pressure required initially is much higher than steady-state because heat exchange with the formation reduces significantly the density of CO2 at the borehole.

  15. Enhanced Injection Molding Simulation of Advanced Injection Molds

    Directory of Open Access Journals (Sweden)

    Béla Zink

    2017-02-01

    Full Text Available The most time-consuming phase of the injection molding cycle is cooling. Cooling efficiency can be enhanced with the application of conformal cooling systems or high thermal conductivity copper molds. The conformal cooling channels are placed along the geometry of the injection-molded product, and thus they can extract more heat and heat removal is more uniform than in the case of conventional cooling systems. In the case of copper mold inserts, cooling channels are made by drilling and heat removal is facilitated by the high thermal conductivity coefficient of copper, which is several times that of steel. Designing optimal cooling systems is a complex process; a proper design requires injection molding simulations, but the accuracy of calculations depends on how precise the input parameters and boundary conditions are. In this study, three cooling circuit designs and three mold materials (Ampcoloy 940, 1.2311 (P20 steel, and MS1 steel were used and compared using numerical methods. The effect of different mold designs and materials on cooling efficiency were examined using calculated and measured results. The simulation model was adjusted to the measurement results by considering the joint gap between the mold inserts.

  16. Corticosteroid and Anesthetic Injections for Muscle Strains and Ligament Sprains in the NFL.

    Science.gov (United States)

    Drakos, Mark; Birmingham, Patrick; Delos, Demetris; Barnes, Ronnie; Murphy, Conor; Weiss, Leigh; Warren, Russell

    2014-07-01

    Administering local anesthetic or corticosteroid injections in professional athletes to allow return to play is common but has traditionally been viewed as suspect and taboo. The skepticism surrounding therapeutic injections stems predominantly from anecdotal experience as opposed to scientific data. The purpose of this paper is to evaluate the current use of corticosteroid injections for muscle strains and ligaments sprains in the National Football League to document player's ability to return to play and possible adverse effects. Athletes from a single National Football League team who received at least one corticosteroid or anesthetic injection for either a muscle strain or ligament sprain during three consecutive seasons were retrospectively reviewed. Thirty-seven injections were given over the three seasons. Injections were either performed blindly or by using ultrasound guidance. Twice as many defensive players were injected than offensive players. The average number of days of conservative treatment before injection was 6.5 days. All players returned to play after injection. There were no complications from any of the injections. Seventeen (55%) players did not miss a single game, and nine (30%) did not miss a single day. Quadriceps strains were associated with the most missed games (four) and the most missed days (36.5). Proximal hamstring strains were second with an average of three missed games and 28 missed days. Corticosteroid injections are a safe and effective therapeutic intervention for treating muscle strains and ligament sprains in order to enable athletes to return to competition earlier.

  17. Risk factors associated with injection initiation among drug users in Northern Thailand

    Directory of Open Access Journals (Sweden)

    Suriyanon Vinai

    2006-03-01

    Full Text Available Abstract Background Circumstances surrounding injection initiation have not been well addressed in many developing country contexts. This study aimed to identify demographic factors, sexual behaviors and drug use characteristics related to injection initiation among drug users in northern Thailand. Methods A cross-sectional survey was conducted among 2,231 drug users admitted to the Northern Drug Treatment Center in Mae Rim, Chiang Mai, Thailand, between February 1, 1999 and December 31, 2000. A multiple logistic regression was employed to identify the independent effects from potential risk factors of transition into injection. Results After controlling for other covariates, being 20 years of age or older, single, ever receiving education, urban residence, and having a history of smoking or incarceration were significantly associated with higher likelihood of injection initiation. Multiple sex partners and an experience of sex abuse were associated with an increased risk of injection initiation. Comparing to those whose first drug was opium, individuals using heroin as their initiation drug had greater risk of injection initiation; conversely, those taking amphetamine as their first drug had less risk of injection initiation. Age of drug initiation was negatively associated with the risk of injection initiation: the older the age of drug initiation, the less the risk of injection initiation. Conclusion Injection initiation was related to several demographic factors, sexual behaviors and drug use characteristics. Understanding these factors will benefit the design of approaches to successfully prevent or delay transition into injection.

  18. Sequential injection gas guns for accelerating projectiles

    Science.gov (United States)

    Lacy, Jeffrey M [Idaho Falls, ID; Chu, Henry S [Idaho Falls, ID; Novascone, Stephen R [Idaho Falls, ID

    2011-11-15

    Gas guns and methods for accelerating projectiles through such gas guns are described. More particularly, gas guns having a first injection port located proximate a breech end of a barrel and a second injection port located longitudinally between the first injection port and a muzzle end of the barrel are described. Additionally, modular gas guns that include a plurality of modules are described, wherein each module may include a barrel segment having one or more longitudinally spaced injection ports. Also, methods of accelerating a projectile through a gas gun, such as injecting a first pressurized gas into a barrel through a first injection port to accelerate the projectile and propel the projectile down the barrel past a second injection port and injecting a second pressurized gas into the barrel through the second injection port after passage of the projectile and to further accelerate the projectile are described.

  19. An Introduction to the Supersonic Molecular Beam Injection

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Recently a new fuelling method with supersonic molecular beam injection (MBI) has been developed and used in the tokamaks experiments successfully. It is economical to develop and maintain. The advantages of supersonic MBI compared with the conventional of gas-puffing method are as follows: deep deposition of fuel, better fuelling efficiency, reduced recycling and pure plasma. Particle and energy confinement can be improved and density limit extended. This review described the Laval nozzle molecular beam and a simple collective model for the injection of a supersonic MBI into the tokamak plasma.

  20. Therapeutic Endoscopic Ultrasonography: Intratumoral Injection for Pancreatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Lawrence A. Shirley

    2013-01-01

    Full Text Available Pancreatic adenocarcinoma is an aggressive disease that has poor outcomes despite maximal traditional therapies. Thus, treatment of this cancer demands innovative strategies to be used in addition to standing therapies in order to provide new avenues of care. Here, we describe the technique of using endoscopic ultrasound in order to directly inject both novel and conventional therapies into pancreatic tumors. We detail the rationale behind this strategy and the many benefits it provides. We then describe our technique in detail, including our experience injecting the AdV-tk adenoviral vector to create an in situ vaccine effect.

  1. Modeling of melt-coolant mixing by bottom injection

    Energy Technology Data Exchange (ETDEWEB)

    Kazachkov, I.V.; Paladino, D.; Sehgal, B.R. [Royal Inst. of Tech., Div. of Nuclear Power Safety, Stockholm (Sweden)

    2001-07-01

    In this paper, the flow characteristics during the coolant injection, with submerged nozzles, at the bottom of a molten pool are studied. The flow pattern developed by the rising coolant is considered for the case of complete coolant vaporization, and the pool-coolant phase distributions are assessed by a modeling approach delivered from literature for a heterogeneous turbulent jet. To calculate the basic characteristics of such flow, integral relationships are proposed for the two-phase boundary layer. The results of numerical computations and approximate solution are compared with the experimental data obtained in the low temperature experiments, conducted in the DECOBI (debris coolability by bottom injection) facility. (authors)

  2. Introducing Bt Gene Into Maize With Ovary Injection

    Institute of Scientific and Technical Information of China (English)

    丁群星; 谢友菊; 戴景瑞; 米景九; 李太元; 田颖川; 乔利亚; 莽克强; 刘宝兰; 王音; 冯平章

    1994-01-01

    It is reported here that Bt toxin gene has been successfully transferred into maize inbred line by ovary injection for the first time both at home and abroad. One transgenic plant (To) has been confirmed by Southern blotting and PCR test, and 71 progenies (T1) from T0 have been obtained through self-pollination. Of these 71 progenies, seven plants demonstrated positive results in the PCR test; four were used to feed Asian corn borer, and certain effect of insect-resistance was observed. The experiments on the ovary injection in Hainan Province have also been repeated, thus providing new chance to the application of genetic engineering to the maize improvement.

  3. Process Optimization for Injection Moulding of Passive Microwave Components

    DEFF Research Database (Denmark)

    Scholz, Steffen G.; Mueller, Tobias; Santos Machado, Leonardo

    2016-01-01

    utilizing the injection moulding process. A design of experiment study has been carried out, varying process parameters such as injection speed, holding pressure, mould- and barrel temperature. The replicated parts are characterized by measuring geometric features and the part weight. Using an evaluation...... algorithm for modelling, the influence of different moulding parameters on the final part quality was assessed. Firstly a process model and secondly a quality model has been calculated. The results shows that part quality can be controlled by monitoring characteristic numbers....

  4. PREDICTION OF GAS INJECTION PERFORMANCE FOR HETEROGENEOUS RESERVOIRS

    Energy Technology Data Exchange (ETDEWEB)

    Martin J. Blunt; Franklin M. Orr Jr

    2000-06-01

    This final report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1996--May 2000 under a three-year grant from the Department of Energy on the ''Prediction of Gas Injection Performance for Heterogeneous Reservoirs''. The advances from the research include: new tools for streamline-based simulation including the effects of gravity, changing well conditions, and compositional displacements; analytical solutions to 1D compositional displacements which can speed-up gas injection simulation still further; and modeling and experiments that delineate the physics that is unique to three-phase flow.

  5. Ultrasonographic study of subcutaneous penile granuloma secondary to silicone injection

    Directory of Open Access Journals (Sweden)

    Lucio Dell'Atti

    2016-10-01

    Full Text Available Penile augmentation has been reported in the literature by injecting various materials. This study reports our experience in management of penile augmentation complications associated with selfpenile injection of silicone liquid. After a careful ultrasound study, the penile skin was excised through a circumferential sub-coronal incision and dissected with the silicon mass. Histology was well-compatible with silicone granulomas. The patient was discharged after 24 hours. Ultrasonography has permitted preoperatively to determine if the plane between the indurated inflammatory tissue and the Buck’s fascia was preserved for the complete surgical excision of affected tissue.

  6. 77 FR 26755 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2012-05-07

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for... final decision allows the continued underground injection by Diamond Shamrock, of the specific...

  7. 78 FR 76294 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2013-12-17

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for... underground injection by Mosaic, of the specific restricted hazardous wastes identified in this exemption...

  8. Learning Runtime Parameters in Computer Systems with Delayed Experience Injection

    OpenAIRE

    Schaarschmidt, Michael; Gessert, Felix; Dalibard, Valentin; Yoneki, Eiko

    2016-01-01

    Learning effective configurations in computer systems without hand-crafting models for every parameter is a long-standing problem. This paper investigates the use of deep reinforcement learning for runtime parameters of cloud databases under latency constraints. Cloud services serve up to thousands of concurrent requests per second and can adjust critical parameters by leveraging performance metrics. In this work, we use continuous deep reinforcement learning to learn optimal cache expiration...

  9. Electrical injection schemes for nanolasers

    DEFF Research Database (Denmark)

    Lupi, Alexandra; Chung, Il-Sug; Yvind, Kresten

    2013-01-01

    The performance of injection schemes among recently demonstrated electrically pumped photonic crystal nanolasers has been investigated numerically. The computation has been carried out at room temperature using a commercial semiconductor simulation software. For the simulations two electrical...... of 3 InGaAsP QWs on an InP substrate has been chosen for the modeling. In the simulations the main focus is on the electrical and optical properties of the nanolasers i.e. electrical resistance, threshold voltage, threshold current and wallplug efficiency. In the current flow evaluation the lowest...... threshold current has been achieved with the lateral electrical injection through the BH; while the lowest resistance has been obtained from the current post structure even though this model shows a higher current threshold because of the lack of carrier confinement. Final scope of the simulations...

  10. Inadvertent intrathecal injection of atracurium

    Directory of Open Access Journals (Sweden)

    Nahid Zirak

    2011-01-01

    Full Text Available This report relates how tracurium was given by mistake, intrathecally, during spinal anesthesia, to a 38-year-old woman, who was a candidate for abdominal hysterectomy. When no analgesia was observed, the mistake in giving the injection was understood. She was evaluated postoperatively by train of four ratio, measuring her breathing rate, eye opening, and protruding of tongue at one, two, twenty-four, and forty-eight hours, and then at one and two weeks, with the final evaluation the following month. The patient had normal timings during the operation and postoperation periods, and no abnormal findings were observed through the first month. This finding was contrary to several studies, which described adverse reactions due to accidental intrathecal injection of neuromuscular blocking drugs.

  11. Injection and extraction for cyclotrons

    CERN Document Server

    Kleeven, W

    2006-01-01

    The main design goals for beam injection are explained and special problems related to a central region with internal ion source are considered. The principle of a PIG source is addressed. The issue of vertical focusing in the cyclotron centre is briefly discussed. Several examples of numerical simulations are given. Different ways of (axial) injection are briefly outlined. A proposal for a magnetostatic axial inflector is given. Different solutions for beam extraction are treated. These include the internal target, extraction by stripping, resonant extraction using a deflector and self-extraction. The different ways of creating a turn-separation are explained. The purpose of different types of extraction devices such as harmonic coils, deflectors and gradient corrector channels are outlined. Several illustrations are given in the form of photographs and drawings.

  12. Tritium pellet injection sequences for TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, W.A.; Milora, S.L.; Attenberger, S.E.; Singer, C.E.; Schmidt, G.L.

    1983-01-01

    Tritium pellet injection into neutral deuterium, beam heated deuterium plasmas in the Tokamak Fusion Test Reactor (TFTR) is shown to be an attractive means of (1) minimizing tritium use per tritium discharge and over a sequence of tritium discharges; (2) greatly reducing the tritium load in the walls, limiters, getters, and cryopanels; (3) maintaining or improving instantaneous neutron production (Q); (4) reducing or eliminating deuterium-tritium (D-T) neutron production in non-optimized discharges; and (5) generally adding flexibility to the experimental sequences leading to optimal Q operation. Transport analyses of both compression and full-bore TFTR plasmas are used to support the above observations and to provide the basis for a proposed eight-pellet gas gun injector for the 1986 tritium experiments.

  13. INJECTION BOTULINUM IN PARALYTIC STRABISMUS

    Directory of Open Access Journals (Sweden)

    Krishna Kishore

    2015-09-01

    Full Text Available AIM: To assess the effectiveness of botulinum toxin injection to the antagonist muscle in paralytic strabismus. OBJECTIVE: To study the effect of botulinum toxin a injection into the antagonist muscle in cases of paralytic strabismus to alleviate diplopia. MATERIAL AND METHODS: This was a tertiary eye care hospital based prospective interventional study in the department of Orthoptics over a period from October 2011 to October 2013. 36 patients with paralytic strabismus of recent onset within 3 months, with chief complaint of double vision were included. RESULTS: The study data analysis of 36 patients of paralytic strabismus of recent onset (within 3 months with chief complaints of double vision showed a ge wise distribution as 3(8.33% in 0 - 20 years, 16(44.44% in 21 - 40 years, 16(44.44% in 41 - 60 years, 1(2.78% > 60 years. g ender wise 26(72.22% males, 10 (27.28% females, a etiology wise 15(41.67% were diabetic, 4(11.11% were traumatic, 11(30.56% were Id iopathic, 2(5.56% were due to CSOM and 4(11.11% due to Diabetes and Hypertension. All patients were treated with botulinum toxin injection to the antagonist nonoperatic muscle and were followed at an interval of 1 week, 1 month and 3 months. Thorough cli nical examination and Diplopia charting were done before and after treatment. CONCLUSION: Injection botulinum into the antagonist muscle during the first three months after the onset allows the patients to enjoy and appreciate fusion in primary gaze without necessity for head turn, Prevents contracture of antagonist muscle. Thus botulinum toxin is useful in the treatment of acute paretic loss of ocular muscle function when surgical treatment of the ocular muscles is not yet possible but the patient is obviously disturbed by diplopia or forced head posture. The procedure is simple, safe and effective method.

  14. Cross-field plasma injection into mirror geometry

    Science.gov (United States)

    Uzun-Kaymak, I. U.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Teodorescu, C.; Witherspoon, F. D.; Young, W.

    2009-09-01

    The Maryland Centrifugal Experiment (MCX) and HyperV Technologies Corp. are collaborating on a series of experiments to test the use of a plasma gun to inject mass and momentum into a magnetic-confinement device. HyperV has designed, built and installed a prototype coaxial gun to drive rotation in MCX. The gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. Preliminary measurements at HyperV indicate the gun generates plasma jets with a mass of 160 µg, velocities up to 90 km s-1 and plasma density in the high 1014 cm-3. This paper emphasizes characteristics of the plasma gun and penetration of the plasma jet through the MCX magnetic field. Plans for future injection experiments are briefly discussed.

  15. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  16. Spin Injection in Indium Arsenide

    Directory of Open Access Journals (Sweden)

    Mark eJohnson

    2015-08-01

    Full Text Available In a two dimensional electron system (2DES, coherent spin precession of a ballistic spin polarized current, controlled by the Rashba spin orbit interaction, is a remarkable phenomenon that’s been observed only recently. Datta and Das predicted this precession would manifest as an oscillation in the source-drain conductance of the channel in a spin-injected field effect transistor (Spin FET. The indium arsenide single quantum well materials system has proven to be ideal for experimental confirmation. The 2DES carriers have high mobility, low sheet resistance, and high spin orbit interaction. Techniques for electrical injection and detection of spin polarized carriers were developed over the last two decades. Adapting the proposed Spin FET to the Johnson-Silsbee nonlocal geometry was a key to the first experimental demonstration of gate voltage controlled coherent spin precession. More recently, a new technique measured the oscillation as a function of channel length. This article gives an overview of the experimental phenomenology of the spin injection technique. We then review details of the application of the technique to InAs single quantum well (SQW devices. The effective magnetic field associated with Rashba spin-orbit coupling is described, and a heuristic model of coherent spin precession is presented. The two successful empirical demonstrations of the Datta Das conductance oscillation are then described and discussed.

  17. Investigation of micro-injection molding based on longitudinal ultrasonic vibration core.

    Science.gov (United States)

    Qiu, Zhongjun; Yang, Xue; Zheng, Hui; Gao, Shan; Fang, Fengzhou

    2015-10-01

    An ultrasound-assisted micro-injection molding method is proposed to improve the rheological behavior of the polymer melt radically, and a micro-injection molding system based on a longitudinal ultrasonic vibration core is developed and employed in the micro-injection molding process of Fresnel lenses. The verification experiments show that the filling mold area of the polymer melt is increased by 6.08% to 19.12%, and the symmetric deviation of the Fresnel lens is improved 15.62% on average. This method improved the filling performance and replication quality of the polymer melt in the injection molding process effectively.

  18. Injection and acceleration of Au31+ in the BNL AGS.

    Energy Technology Data Exchange (ETDEWEB)

    Fischer,W.; Ahrens, L.; Brown, K.; Gardner, C.; Glenn, W.; Huang, H.; Mapes, M.; Smart, L.; Thieberger, P.; Tsoupas, N.; Zhang, S.Y.; Zeno, K.; Omet, C.; Spiller, P.

    2008-06-23

    Injection and acceleration of ions in a lower charge state reduces space charge effects, and, if further elcctron stripping is needed, may allow elimination of a stripping stage and the associated beam losses. The former is of interest to the accelerators in the GSI FAIR complex, the latter for BNL RHIC collider operation at energies lower than the current injection energy. Lower charge state ions, however, have a higher likelihood of electron stripping which can lead to dynamic pressures rises and subsequent beam losses. We report on experiments in the AGS where Au{sup 31+} ions were injected and accelerated instead of the normally used Au{sup 77+} ions. Beam intensities and the average pressure in the AGS ring are recorded, and compared with calculations for dynamic pressures and beam losses. The experimental results will be used to benchmark the StrahlSim dynamic vacuum code and will be incorporated in the GSI FAIR SIS100 design.

  19. Spin injection from a normal metal into a mesoscopic superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Michael J.; Kolenda, Stefan [Institut fuer Nanotechnologie, KIT, 76021 Karlsruhe (Germany); Huebler, Florian [Institut fuer Nanotechnologie, KIT, 76021 Karlsruhe (Germany); Center for Functional Nanostructures, KIT, 76131 Karlsruhe (Germany); Institut fuer Festkoerperphysik, KIT, 76021 Karlsruhe (Germany); Loehneysen, Hilbert v. [Center for Functional Nanostructures, KIT, 76131 Karlsruhe (Germany); Institut fuer Festkoerperphysik, KIT, 76021 Karlsruhe (Germany); Physikalisches Institut, KIT, 76128 Karlsruhe (Germany); Beckmann, Detlef [Institut fuer Nanotechnologie, KIT, 76021 Karlsruhe (Germany); Center for Functional Nanostructures, KIT, 76131 Karlsruhe (Germany)

    2013-07-01

    We report on nonlocal transport in superconductor hybrid structures, with ferromagnetic as well as normal-metal tunnel junctions attached to the superconductor. In the presence of a strong Zeeman splitting of the density of states, both charge and spin imbalance is injected into the superconductor. While previous experiments demonstrated spin injection from ferromagnetic electrodes, we show that spin imbalance is also created for normal-metal injector contacts. Using the combination of ferromagnetic and normal-metal detectors allows us to directly discriminate between charge and spin injection, and demonstrate a complete separation of charge and spin imbalance. The relaxation length of the spin imbalance is of the order of several μm and is found to increase with a magnetic field, but is independent of temperature. We further discuss possible relaxation mechanisms for the explanation of the spin relaxation length.

  20. Tangential injection to a supersonic flow on a blunted nose

    Science.gov (United States)

    Chuvakhov, P. V.; Egorov, I. V.; Ezhov, I. V.; Ezhov, I. V.; Novikov, I. V.; Vasilevskiy, E. B.

    2017-06-01

    The flow pattern and the heat §ux to a body surface at a tangential gas injecting have been investigated. The cooling air was injected to a §ow through the tangential axisymmetric slot on the spherically blunted cylinder. The experiments were conducted at M∞ = 6, Re∞,Rw = 0.76 · 106, angle of attack α = 0°-30°, and the slot width hk/Rw = 0-0.021. The mass rate of the injecting gas was G∗ = gj/(πρ∞ u2∞w) = 0- 0.16. It has been shown that maximum of the heat §ux toward the sphere surface can be sufficiently decreased. Numerical investigations have been carried out using the solution of the Navier-Stokes equations for axisymmetric two-dimensional (2D) viscous compressible unsteady §ows at α = 0.

  1. Tracing Injection Fluids in Engineered Geothermal Systems

    Science.gov (United States)

    Rose, P. E.; Leecaster, K.; Mella, M.; Ayling, B.; Bartl, M. H.

    2011-12-01

    The reinjection of produced fluids is crucial to the effective management of geothermal reservoirs, since it provides a mechanism for maintaining reservoir pressures while allowing for the disposal of a toxic byproduct. Tracers are essential to the proper location of injection wells since they are the only known tool for reliably characterizing the flow patterns of recirculated fluids. If injection wells are placed too close to production wells, then reinjected fluids do not have sufficient residence time to extract heat from the reservoir and premature thermal breakthrough results. If injection wells are placed too far away, then the reservoir risks unacceptable pressure loss. Several thermally stable compounds from a family of very detectable fluorescent organic compounds (the naphthalene sulfonates) were characterized and found to be effective for use as geothermal tracers. Through batch-autoclave reactions, their Arrhenius pseudo-first-order decay-rate constants were determined. An analytical method was developed that allows for the laboratory determination of concentrations in the low parts-per-trillion range. Field experiments in numerous geothermal reservoirs throughout the world have confirmed the laboratory findings. Whereas conservative tracers such as the naphthalene sulfonates are effective tools for indicating interwell flow patterns and for measuring reservoir pore volumes, 'reactive' tracers can be used to constrain fracture surface area, which is the effective area for heat extraction. This is especially important for engineered geothermal system (EGS) wells, since reactive tracers can be used to measure fracture surface area immediately after drilling and while the well stimulation equipment is still on site. The reactive properties of these tracers that can be exploited to constrain fracture surface area are reversible sorption, contrasting diffusivity, and thermal decay. Laboratory batch- and flow-reactor experiments in combination with numerical

  2. Corticosteroid Injections for Common Musculoskeletal Conditions.

    Science.gov (United States)

    Foster, Zoë J; Voss, Tyler T; Hatch, Jacquelynn; Frimodig, Adam

    2015-10-15

    Family physicians considering corticosteroid injections as part of a comprehensive treatment plan for musculoskeletal diagnoses will find few high-quality studies to assist with evidence-based decision making. Most studies of corticosteroid injections for the treatment of osteoarthritis, tendinopathy, bursitis, or neuropathy include only small numbers of patients and have inconsistent long-term follow-up. Corticosteroid injections for the treatment of adhesive capsulitis result in short-term improvements in pain and range of motion. For subacromial impingement syndrome, corticosteroid injections provide short-term pain relief and improvement in function. In medial and lateral epicondylitis, corticosteroid injections offer only short-term improvement of symptoms and have a high rate of symptom recurrence. Corticosteroid injections for carpal tunnel syndrome may help patients avoid or delay surgery. Trigger finger and de Quervain tenosynovitis may be treated effectively with corticosteroid injections. Patients with hip or knee osteoarthritis may have short-term symptom relief with corticosteroid injections.

  3. Challenges of titanium metal injection moulding

    CSIR Research Space (South Africa)

    Benson, JM

    2007-11-01

    Full Text Available . With the increased availability of higher quality titanium powder, metal injection moulding offers an attractive method for producing small, intricate components at a reasonable cost. This paper will present an overview of the metal injection moulding process...

  4. Superovulatory response to a single subcutaneous injection of Folltropin-V in beef cattle.

    Science.gov (United States)

    Bo, G A; Hockley, D K; Nasser, L F; Mapletoft, R J

    1994-11-01

    A series of 4 experiments were designed to evaluate the feasibility of superstimulation in beef cattle with a single sc injection of the porcine pituitary extract, Folltropin-V. In the preliminary study (Experiment 1), superovulatory response of cows (n=7) treated with a single sc injection of 400 mg NIH-FSH-P1 Folltropin-V was not different than that of cows (n=8) superstimulated with twice daily im injections over 4 d, or a single sc injection plus an injection of eCG (n=12). Experiments 2 and 3 were designed to determine the optimal site of a single sc injection. In Experiment 2, cows (n=25) with body condition scores (BCS) of 1 to 2 were used. The mean number of CL counted and ova/embryos collected was lower (Pcows treated with the single sc injection in the neck region than in cows treated with a single sc injection behind the shoulder, or with the twice daily im injection treatment. In Experiment 3, cows (n=49) with BCS of 3 to 5 were used. There were no differences in the number of CL, total ova/embrvos collected, fertilized ova and transferable embryos whether treatments were given in the neck region or behind the shoulder, or whether the cows were implanted or not implanted with Syncro-Mate-B. Experiment 4 was designed to determine the optimal superstimulatory dosage of Folltropin-V administered by a single sc injection. Superovulatory response of cows treated with the higher doses (400 mg, 600 mg or 800 mg NIH-FSH-P1) was higher (Por=10 mm) follicles at the time of ova/embryo collection was higher (Pcows treated with 800 mg than with 400 or 200 mg. It was concluded that a single, bolus sc injection of 400 mg NIH-FSH-P1 of Folltropin-V is as efficacious as the 4-d, twice daily im treatment protocol for inducing superovulation in beef cows. The amount of subcutaneous fat and site of injection appeared to affect the efficacy of a single sc injection; a single bolus sc injection of Folltropin-V behind the shoulder resulted in the most predictable

  5. The effect of injection duration and injection site on pain and bruising of subcutaneous injection of heparin.

    Science.gov (United States)

    Pourghaznein, Tayebe; Azimi, Amir Vahedian; Jafarabadi, Mohammad Asghari

    2014-04-01

    To determine and compare the effects of four methods of subcutaneous heparin injection on pain and bruising in abdomen and thighs. Subcutaneous heparin injection is a common nursing clinical intervention. Nurses frequently inject heparin subcutaneously and this action often results in some complications such as bruising, haematoma, pain and induration in the injection site. There are also some other factors inducing complications associated with heparin injection, including the injection site and the injection duration. A quasi-experimental within-subject design. This study was conducted on 90 patients with COPD hospitalised in two ICU wards at two teaching hospitals in urban areas of Iran. They were administered heparin subcutaneously, 4000 units every 12 hours. Each patient received four injections in their abdomen and thighs, using four different methods. The number and size of bruising at the injection site were measured through a flexible millimetre ruler, 48 hours after each injection. The severity of pain was measured through pain visual analogue scale immediately after each injection. Collected data were analysed by descriptive and analytical statistics using spss 11.5 software. In the method 15 seconds injection duration and waiting for 5 seconds before withdrawing the needle, the number of bruising was significantly lower and size of bruising was significantly smaller, but no significant difference was found in the severity of pain. However, in other methods, the severity of pain in thighs was significantly higher than in abdomen, but no statistically significant difference was reported between the size and number of bruising in abdomen and thighs. The method 15 seconds injection duration and waiting for 5 seconds before withdrawing the needle is recommended to be used for subcutaneous heparin injection by clinical nurses. As to the results, the severity of pain in abdomen was lower than in thighs. This study proposed a suitable method for subcutaneous

  6. On the Possibility of Condensation during Supercritical Fuel Injection

    Science.gov (United States)

    Qiu, Lu; Reitz, Rolf

    2014-11-01

    Supercritical fuel injection into a nitrogen environment was simulated using Peng-Robinson equation of state. The real gas simulation was found to match the experimental injectant density much better than the ideal gas simulation, emphasizing the importance of applying realistic equation of state model. Possible fuel condensation processes were also investigated by considering the stability of the single phase by utilizing fundamental thermodynamics principles. Several conclusions from the experiments are also seen from the simulations. First, though both the injection and chamber pressures are above the critical pressure of the injectant, condensation can become possible as long as their temperature difference is large enough, and when this occurs, the fluid is able to enter the two-phase region. Condensation is found to be enhanced when the chamber temperature is further reduced, indicating that the fluid is in a state further away from the phase border. In addition, the newly formed condensed phase is found to exist only in the jet boundary where there are strong interactions between the ``hot'' injectant and the ``cold'' nitrogen. Finally, it was concluded that the local strong heat and mass exchange sent the mixture into the two-phase region by crossing the dew point line with the commencement of condensation. The research work was sponsored by Department of Energy and Sandia National Laboratories through the Advanced Engine Combustion Program (MOU 04-S-383).

  7. Spin injection and relaxation in a mesoscopic superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Aprili, Marco; Quay, Charis; Chevalier, Denis; Dutreix, Clement [Laboratoire de Physique des Solides, CNRS UMR-8502, Bat. 510, Universite Paris-Sud, 91405 Orsay Cedex (France); Bena, Cristina [Institut de Physique Theorique, CEA/Saclay, Orme des Merisiers, 91190 Gif-sur-Yvette Cedex (France); Strunk, Christoph [Institute for Experimental and Applied Physics, University of Regensburg, 93040 Regensburg (Germany)

    2015-07-01

    Injecting spin-polarized electrons or holes into a superconductor and removing Cooper pairs creates both spin and charge imbalances. We have investigated the relaxation of the out-of-equilibrium magnetization induced by spin injection. First, we measured the spin and charge relaxation times (t{sub S} and t{sub Q}) by creating a dynamic equilibrium between continuous injection and relaxation, this leads to constant-in-time spin and charge accumulation proportional to their respective relaxation times. Using a mesoscopic ''absolute'' spin-valve, we obtained t{sub S} and t{sub Q} by probing the difference on the chemical potential between quasiparticles and Cooper pairs. We observed that spin (charge) accumulation dominates at low (high) injection current. This artificially generates spin-charge separation as theoretically first predicted by Kivelson and Rokhsar. Second, we directly measured the spin relaxation time in the frequency space and found t{sub S} = 1-10 ns consistent with results from constant current injection. Finally, we measured the spin coherence time of the out-of-equilibrium quasi-particles by performing an electron spin resonance experiment.

  8. Behavioral, hormonal and central serotonin modulating effects of injected leptin.

    Science.gov (United States)

    Haleem, Darakhshan J; Haque, Zeba; Inam, Qurrat-ul-Aen; Ikram, Huma; Haleem, Muhammad Abdul

    2015-12-01

    Leptin is viewed as an important target for developing novel therapeutics for obesity, depression/anxiety and cognitive dysfunctions. The present study therefore concerns behavioral, hormonal and central serotonin modulating effects of systemically injected leptin. Pharmacological doses (100 and 500 μg/kg) of leptin injected systemically decreased 24h cumulative food intake and body weight in freely feeding rats and improved acquisition and retention of memory in Morris water maze test. Potential anxiety reducing, hormonal and serotonin modulating effects of the peptide hormone were determined in a separate experiment. Animals injected with 100 or 500 μg/kg leptin were tested for anxiety in an elevated plus maze test 1h later. A significant increase in the number of entries and time passed in open arm of the elevated plus maze in leptin injected animals suggested pronounced anxiety reducing effect. Moreover, circulating levels of leptin correlated significantly with anxiety reducing effects of the peptide hormone. Serum serotonin increased and ghrelin decreased in leptin injected animals and correlated, positively and negatively respectively, with circulating leptin. Corticosterone increased at low dose and levels were normal at higher dose. Serotonin metabolism in the hypothalamus and hippocampus decreased only at higher dose of leptin. The results support a role of leptin in the treatment of obesity, anxiety and cognitive dysfunctions. It is suggested that hormonal and serotonin modulating effects of leptin can alter treatment efficacy in particularly comorbid conditions.

  9. Influence of Fuel Injection on Gasoline Engine Performance

    Directory of Open Access Journals (Sweden)

    Zong-zheng Ma

    2013-04-01

    Full Text Available Because of the most common method of preparing the fuel-air mixture for gasoline-fueled engines is port fuel injection (PFI. For reducing the wall-film entering the cylinder in liquid phase, the phenomena of wall-film entering the cylinder in liquid phase should be at minimum lever or be avoided. So the first thing for learning the wall-film is to detect the way of the wall-film entering the cylinder. Therefore, the way of the wall-film enter the cylinder in liquid phase is detected by changing the temperature of the wall-film location and time for wall-film evaporated. Then the way is validated by experiment test bed and it is improved that the way is feasible. At the end the influence of injection timing and fuel ratio on engine performance is studied based on the test bed.The results show that regardless of the expansion stroke or the intake stroke fuel injection the injection timing delay will decrese the engine power and  make emission deterioration meanwhile the twice fuel injection can improve the fuel film evaporation resulting of high-speed airflow of intake charge.

  10. Injectivity Errors in Simulation of Foam EOR

    NARCIS (Netherlands)

    Leeftink, T.N.; Latooij, C.A.; Rossen, W.R.

    2013-01-01

    Injectivity is a key factor in the economics of foam EOR processes. Poor injectivity of lowmobility foam slows the production of oil and allows more time for gravity segregation of injected gas. The conventional Peaceman equation, when applied in a large grid block, makes two substantial errors in e

  11. Injectivity errors in simulation of foam EOR

    NARCIS (Netherlands)

    Leeftink, T.N.; Latooij, C.A.; Rossen, W.R.

    2014-01-01

    Injectivity is a key factor in the economics of foam enhanced oil recovery (EOR) processes. Poor injectivity of low-mobility foam slows the production of oil and allows more time for gravity segregation of injected gas. The conventional Peaceman equation (1978), when applied in a large grid block, m

  12. The Three Generations of Flow Injection Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    2004-01-01

    The characteristics of the three generations of flow injection analysis, that is, FIA, sequential injection analysis (SIA), and bead injection-lab-on-valve (BI-LOV), are briefly outlined, their individual advantages and shortcomings are discussed, and selected practical applications are presented....

  13. The effect of subcutaneous injection duration on bruising due to Clexane (enoxaparin injection in patients with ACS hospitalized in CCU and Post CCU wards in Vali-e Asrhospital of Fasain 2014

    Directory of Open Access Journals (Sweden)

    Bijani M.

    2016-11-01

    Full Text Available The aim of this study was to compare the duration of subcutaneous injection of Clexane on the bruising caused by the same. The sample included 80 patients with ACS under treatment with Clexanein CCU and Post CCU wards. For each patient, two 10-second subcutaneous injections (experimental group and a 30-second injection (control group of Clexane were performed in the abdominal area. The interval between injections was 12 hours and the bruising was measured using a flexible plastic ruler 48 and 60 hours after each injection. The size of bruising caused by 30-sec. injections was significantly less than that of 10-second injections. The average size of bruising for30-second injections in 48 and 60 hours after injection was 15.65 ±10.67 and 12.98 ± 8.12respectively. No bruising conditions observed 48 and 60 hours after 30-second injections were significantly lower than after 10- second injections. In most cases, bruising after 10- and 30-second injections was significantly higher in women than in men. There was no significant difference between bruising and age. It is suggested that the subcutaneous injection duration be increased to 30 seconds to enhance the quality of care and minimize the unpleasant and stressful experience for patients.

  14. Ion injection optimization for a linear Paul trap to study intense beam propagation

    Directory of Open Access Journals (Sweden)

    Moses Chung

    2007-01-01

    Full Text Available The Paul Trap Simulator Experiment (PTSX is a linear Paul trap whose purpose is to simulate the nonlinear transverse dynamics of intense charged particle beam propagation in periodic-focusing quadrupole magnetic transport systems. Externally created cesium ions are injected and trapped in the long central electrodes of the PTSX device. In order to have well-matched one-component plasma equilibria for various beam physics experiments, it is important to optimize the ion injection. From the experimental studies reported in this paper, it is found that the injection process can be optimized by minimizing the beam mismatch between the source and the focusing lattice, and by minimizing the number of particles present in the vicinity of the injection electrodes when the injection electrodes are switched from the fully oscillating voltage waveform to their static trapping voltage.

  15. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, Martin J.; Orr, Franklin M.

    1999-05-17

    This report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1997 - September 1998 under the second year of a three-year grant from the Department of Energy on the "Prediction of Gas Injection Performance for Heterogeneous Reservoirs." The research effort is an integrated study of the factors affecting gas injection, from the pore scale to the field scale, and involves theoretical analysis, laboratory experiments, and numerical simulation. The original proposal described research in four areas: (1) Pore scale modeling of three phase flow in porous media; (2) Laboratory experiments and analysis of factors influencing gas injection performance at the core scale with an emphasis on the fundamentals of three phase flow; (3) Benchmark simulations of gas injection at the field scale; and (4) Development of streamline-based reservoir simulator. Each state of the research is planned to provide input and insight into the next stage, such that at the end we should have an integrated understanding of the key factors affecting field scale displacements.

  16. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, Michael J.; Orr, Franklin M.

    1999-05-26

    This report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1996 - September 1997 under the first year of a three-year Department of Energy grant on the Prediction of Gas Injection Performance for Heterogeneous Reservoirs. The research effort is an integrated study of the factors affecting gas injection, from the pore scale to the field scale, and involves theoretical analysis, laboratory experiments and numerical simulation. The original proposal described research in four main areas; (1) Pore scale modeling of three phase flow in porous media; (2) Laboratory experiments and analysis of factors influencing gas injection performance at the core scale with an emphasis on the fundamentals of three phase flow; (3) Benchmark simulations of gas injection at the field scale; and (4) Development of streamline-based reservoir simulator. Each stage of the research is planned to provide input and insight into the next stage, such that at the end we should have an integrated understanding of the key factors affecting field scale displacements.

  17. Clinical experiences of normal saline pressed injection via lumbar puncture in the treatment of apnea due to acute tonsillar hernia%采用腰穿加压注液方法抢救急性枕骨大孔疝致呼吸停止的临床疗效

    Institute of Scientific and Technical Information of China (English)

    孟庆虎; 曲春城; 魏麟; 李新钢; 李刚; 费昶; 孙金龙; 王成伟; 张庆林

    2012-01-01

    Objective To summarize the clinical experiences of normal saline pressed injection via lumbar puncture in the treatment of acute tonsillar hernia induced apnea.This procedure was routinely carried out after external ventricular drainage and/or lesion removal via open craniotomy.Methods During the period of 1969 to 2005,a total of 43 patients failed to regain respiratory after external ventricular drainage using rapid small hole cranio-puncture apparatus or lesion removal via open craniotomy.They underwent lumbar puncture and normal saline was pressed injected via a lumbar puncture needle.The patient data were retrospectively analyzed.Results Eleven of 43 patients had spontaneous respiration and fully recovered (25.6% ),16 patients regained respiration but died eventually (37.2% ) and 16 patients failed to regain respiration ( 37.2% ).The effective rate was 62.8%.Conclusion For the patients failing to regain respiration after external ventricular drainage or supratentorial lesion removal via open craniotomy,the conservative treatment should not be the first choice.The pressed injection of normal saline via lumbar puncture may rescue some patients.%目的 总结应用快速细孔钻颅脑室体外引流术或开颅病变清除减压术后,进行腰穿加压注液抢救枕骨大孔疝所致呼吸骤停患者的经验.方法 自1969至2005年山东大学齐鲁医院及山东大学第二医院共同采用腰穿加压注液方法,救治43例急性枕骨大孔疝患者,43例均为进行快速细孔钻颅脑室外引流或幕上病变开颅清除减压术后,自主呼吸仍不恢复者.结果 43例中11例(25.6%)不仅恢复自主呼吸且完全康复,16例(37.2%)出现不同时间的自主呼吸但最终死亡,无自主呼吸恢复迹象者16例(37.2%).结论 因急性枕骨大孔疝致呼吸停止,应用快速细孔钻颅脑室引流,或幕上病变开颅清除减压术后,自主呼吸仍无恢复的患者,给予腰穿加压注液有可能使部分患者获救.

  18. Electrical Injection Schemes for Nanolasers

    DEFF Research Database (Denmark)

    Lupi, Alexandra; Chung, Il-Sug; Yvind, Kresten

    2014-01-01

    Three electrical injection schemes based on recently demonstrated electrically pumped photonic crystal nanolasers have been numerically investigated: 1) a vertical p-i-n junction through a post structure; 2) a lateral p-i-n junction with a homostructure; and 3) a lateral p-i-n junction....... For this analysis, the properties of different schemes, i.e., electrical resistance, threshold voltage, threshold current, and internal efficiency as energy requirements for optical interconnects are compared and the physics behind the differences is discussed....

  19. Injected radiotracer techniques in hydrology

    Science.gov (United States)

    Rao, S. M.

    1984-08-01

    Radioactive tracers which have several advantages over conventional tracers made significant contributions to the development of the injected tracer method in hydrology. A review of the nuclear and the physico-chemical characteristics of the possible radiotracer compounds leads us to conclude that the most effective groundwater tracers are tritiated water (HTO),82Br- and58Co or60Co as a hexacyanocobaltate complex. A discussion of the various case studies in India and abroad covering the three groups of applications mentioned helps us to conclude that well established radiotracer methods with associated interpretational techniques are available for many short range studies in surface and subsurface hydrology.

  20. Single Performance Optimization of Micro Metal Injection Molding for the Highest Green Strength by Using Taguchi Method

    Directory of Open Access Journals (Sweden)

    M.H.I Ibrahim

    2010-06-01

    Full Text Available Micro metal injection molding is drawing attention recently as one the most cost effective processes in powder metallurgy to produce small-scale intricate part and competitive cost for mass production of micro components where it is greatly influenced by injection parameter. Thus, this paper investigated the optimization of highest green strength which plays an important characteristic in determining the successful of micro MIM. Stainless steel SS 316L was used with composite binder, which consists of PEG and PMMA while SA works as a surfactant. Feedstock with 61.5% with several injection parameters were optimized which highly significant through screening experiment such as injection pressure(A, injection temperature(B, mold temperature(C, injection time(D and holding time(E. Besides that, interaction effects between injection pressure, injection temperature and mold temperature were also considered to optimize in the Taguchi’s orthogonal array. Analysis of variance (ANOVA in terms of signal-to-noise ratio (S/N-larger is better for green strength was also presented in this paper. Result shows that interaction between injection temperature and mold temperature (BxC give highest significant factor followed by interaction between injection pressure and injection temperature (AxB. Single factor that also contributes to significant optimization are mold temperature(C, injection time (D and injection pressure (A. Overall, this study shows that Taguchi method would be among the best method to solve the problem with minimum number of trials.

  1. Porous media heat transfer for injection molding

    Energy Technology Data Exchange (ETDEWEB)

    Beer, Neil Reginald

    2016-05-31

    The cooling of injection molded plastic is targeted. Coolant flows into a porous medium disposed within an injection molding component via a porous medium inlet. The porous medium is thermally coupled to a mold cavity configured to receive injected liquid plastic. The porous medium beneficially allows for an increased rate of heat transfer from the injected liquid plastic to the coolant and provides additional structural support over a hollow cooling well. When the temperature of the injected liquid plastic falls below a solidifying temperature threshold, the molded component is ejected and collected.

  2. Fear of repeated injections in children younger than 4 years receiving subcutaneous allergy immunotherapy.

    Science.gov (United States)

    de Vos, Gabriele; Shankar, Viswanathan; Nazari, Ramin; Kooragayalu, Shravan; Smith, Mitchell; Wiznia, Andrew; Rosenstreich, David

    2012-12-01

    Allergy immunotherapy during early childhood may have potential benefits for the prevention of asthma and allergy morbidity. However, subcutaneous immunotherapy has not yet been prospectively researched in children younger than 4 years, primarily because of safety concerns, including the fear and psychological distress young children may experience with repeated needle injections. To quantify fear in atopic children younger than 4 years with a history of wheezing who are receiving subcutaneous immunotherapy. Fear of injection was graded during a total of 788 immunotherapy injection visits in 18 children (age, 37 months; SD, 9 months) receiving subcutaneous allergy immunotherapy. The parent and the injection nurse assigned fear scores on a scale of 0 to 10 after each injection visit. At the time of analysis, children had a median of 49 injection visits (range, 12-88) during a median study period of 81.5 weeks (range, 15-165 weeks). Fifteen children (83%) lost their fear of injections during the study. A fear score of 0 was achieved after a mean of 8.4 visits (SD, 7.4). The more injection visits were missed, the more likely children were to retain fear of injections (hazard ratio, 0.13; 95% confidence interval, 0.02-1.02; P=.05). Age, adverse events, number of injections at each visit, and change of injection personnel were not associated with increased fear. Our analysis suggests that most children receiving weekly subcutaneous immunotherapy lose their fear of injections during the treatment course. Children with increased intervals between visits may be at higher risk of experiencing fear of injections. clinicaltrial.gov identifier NCT01028560. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. Maximum magnitude earthquakes induced by fluid injection

    Science.gov (United States)

    McGarr, Arthur F.

    2014-01-01

    Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.

  4. Maximum magnitude earthquakes induced by fluid injection

    Science.gov (United States)

    McGarr, A.

    2014-02-01

    Analysis of numerous case histories of earthquake sequences induced by fluid injection at depth reveals that the maximum magnitude appears to be limited according to the total volume of fluid injected. Similarly, the maximum seismic moment seems to have an upper bound proportional to the total volume of injected fluid. Activities involving fluid injection include (1) hydraulic fracturing of shale formations or coal seams to extract gas and oil, (2) disposal of wastewater from these gas and oil activities by injection into deep aquifers, and (3) the development of enhanced geothermal systems by injecting water into hot, low-permeability rock. Of these three operations, wastewater disposal is observed to be associated with the largest earthquakes, with maximum magnitudes sometimes exceeding 5. To estimate the maximum earthquake that could be induced by a given fluid injection project, the rock mass is assumed to be fully saturated, brittle, to respond to injection with a sequence of earthquakes localized to the region weakened by the pore pressure increase of the injection operation and to have a Gutenberg-Richter magnitude distribution with a b value of 1. If these assumptions correctly describe the circumstances of the largest earthquake, then the maximum seismic moment is limited to the volume of injected liquid times the modulus of rigidity. Observations from the available case histories of earthquakes induced by fluid injection are consistent with this bound on seismic moment. In view of the uncertainties in this analysis, however, this should not be regarded as an absolute physical limit.

  5. The LHC injection kicker magnet

    CERN Document Server

    Ducimetière, Laurent; Barnes, M J; Wait, G D

    2003-01-01

    Proton beams will be injected into LHC at 450 GeV by two kicker magnet systems, producing magnetic field pulses of approximately 900 ns rise time and up to 7.86 s flat top duration. One of the stringent design requirements of these systems is a flat top ripple of less than ± 0.5%. Both injection systems are composed of 4 travelling wave kicker magnets of 2.7 m length each, powered by pulse forming networks (PFN's). To achieve the required kick strength of 1.2 Tm, a low characteristic impedance has been chosen and ceramic plate capacitors are used to obtain 5 Omega. Conductive stripes in the aperture of the magnets limit the beam impedance and screen the ferrite. The electrical circuit has been designed with the help of PSpice computer modelling. A full size magnet prototype has been built and tested up to 60 kV with the magnet under ultra high vacuum (UHV). The pulse shape has been precision measured at a voltage of 15 kV. After reviewing the performance requirements the paper presents the magnet...

  6. Groin injecting among a community-recruited sample of people who inject drugs in Thailand.

    Science.gov (United States)

    Ti, Lianping; Hayashi, Kanna; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-01-16

    Use of the femoral vein for the injection of illicit drugs (i.e. groin injecting) has been linked to various health-related harms, including deep vein thrombosis. However, little is known about the prevalence of groin injecting and factors that predict this practice among people who inject drugs (PWID) in Thailand. We sought to investigate the prevalence and factors associated with groin injecting in Bangkok, Thailand. Data were derived from the Mitsampan Community Research Project in Bangkok between July and October 2011. Multivariate logistic regression was used to identify factors associated with groin injecting in the last six months. Among 437 participants, 34.3% reported groin injecting in the last six months. In multivariate analyses, factors positively associated with groin injecting included: having higher than secondary education (adjusted odds ratio [AOR] = 1.59; 95% confidence interval [CI]: 1.00 - 2.56), weekly midazolam injection (AOR = 8.26; 95% CI: 5.04 - 14.06), and reports of having had drugs planted on oneself by police (AOR = 2.14; 95% CI: 1.37 - 3.36). Over one-third of our sample of Thai PWID reported recent groin injecting. Frequent midazolam injection and higher education were found to be associated with groin injecting. That high intensity PWID were more likely to inject in the groin is concerning given the known negative consequences associated with the groin as a site of injection. Additionally, PWID who reported drug planting by police were more likely to inject in the groin, suggesting that reliance on law enforcement approaches may undermine safe injection practices in this setting. These findings highlight the need for evidence-based interventions to address the harms associated with groin injecting, including efforts to alert PWID to risks of groin injecting, the distribution of appropriate injecting equipment, and efforts to encourage use of other injecting sites.

  7. Characterisation of demoulding parameters in micro‑injection moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Tosello, Guido; Dimov, S.S.

    2015-01-01

    on the process factors that affect parts’ quality. Using a Cyclic Olefin Copolyme (COC) microfluidics demonstrator, the demoulding performance was studied as a function of four process parameters (melt temperature, mould temperature, holding pressure and injection speed), employing the design of experiment...... that there was a direct correlation between the applied pressure during part filling, holding phases and the demoulding characteristic factors of the μ-IM cycle such as ejection force, integral and time....

  8. Optical Injection Locking of a VCSEL in an OEO

    Science.gov (United States)

    Strekalov, Dmitry; Matsko, Andrey; Savchenkov, Anatoliy; Yu, Nan; Maleki, Lute

    2009-01-01

    Optical injection locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface- emitting laser (VCSEL) that is an active element in the frequency-control loop of an opto-electronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency resonance. This particular optical-injection- locking scheme is expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. Inasmuch as the microwave power circulating in the frequency-control loop is a dynamic frequency-control variable (and, hence, cannot be stabilized), there arises a need for another means of stabilizing the wavelength. The present optical-injection-locking scheme satisfies the need for a means to stabilize the wavelength against microwave- power fluctuations. It is also expected to afford stabilization against temperature and current fluctuations. In an experiment performed to demonstrate this scheme, wavelength locking was observed when about 200 W of the output power of a commercial tunable diode laser was injected into a commercial VCSEL, designed to operate in the wavelength range of 795+/-3 nm, that was generating about 200 microW of optical power. (The use of relatively high injection power levels is a usual practice in injection locking of VCSELs.)

  9. Pharmacy and clinic partnerships to expand access to injectable contraception.

    Science.gov (United States)

    Monastersky Maderas, Nicole J; Landau, Sharon Cohen

    2007-01-01

    To explore the potential of pharmacist-administered contraceptive injections and feasibility and acceptability among patients, pharmacists, and clinicians. Throughout California, 27 pharmacists practicing in 26 community independent and chain pharmacies partnered with 19 clinics/physician offices. In spring 2003, Pharmacy Access Partnership launched a 2-year demonstration program in which established users of depot medroxyprogesterone acetate (e.g., Depo-Provera-Pfizer) hormonal contraception at participating clinics were given the option of returning to their regular clinic for reinjection or going to a participating pharmacist trained in injection technique and contraceptive management. Program feasibility and acceptability by patients, pharmacists, and clinicians were evaluated to offer insights into the potential of pharmacistadministered depot medroxyprogesterone injections. Intake forms collected during pharmacy reinjection visits, data from interviews with pharmacists and clinicians, and evaluations with patients. To determine whether contraceptive reinjection at a pharmacy is feasible and acceptable for patients, pharmacists, and clinicians and to determine the characteristics of women most likely to use the service. A total of 69 women received 143 depot medroxyprogesterone injections during the project. Patients were ethnically and racially diverse and spanned a wide age range (19-45 years). Women 20 years of age or older used pharmacists' services more frequently than did younger patients, perhaps because they were more familiar with the injections and they more often worked, therefore needing the expanded hours offered by the community pharmacy setting. Experiences of two pharmacies with successful programs are described. The pharmacy option for reinjection is most viable for women who can comfortably manage their injection cycle, prefer not to have to schedule a clinic appointment quarterly, and do not require the ongoing attention and appointment

  10. CENTRAL CONVEYING & AUTO FEEDING SYSTEMS FOR AN INJECTION MOLDING SHOP

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar

    2011-08-01

    Full Text Available Nowadays injection molding is probably the most important method of Processing of consumer and industrial goods, and is performed everywhere in the world. The developing of injection molding becomes a competition from day to day. This Process now integrated with computer control make the production better in quality and Better quantity. The trends of producing a plastics product in injection molding industries are recently changing from traditional method to using the FEA analysis. For injection molding industries, time and cost is very important aspects to consider because these two aspectswill directly related to the profits at a company. The next issue toconsider, to get the best parameter for the injection molding process, plastics has been waste. Through the experiment, operator will use large amount of plastics material to get the possibly parameters to setup the machine.To produce the parts with better quality and quantity these molding defects are the major obstacles in achieving the targets with quality & quantity. Various defects like Short shot, colour streaks and low productivity rates are associated with the material mixing and feeding as molded plastics are often a blend of two or more materials. Colors (master batch and other additives are often mixed (blended with the raw plastic material prior to the molding process in molding plants. So it is very necessary to work out auto blending and auto feeding of plasticgranules to the machine hopper. This paper will cover the studyof automatic blending unit & central conveying system for plasticgranule feeding to machine & will help in optimizing the injection molding process.

  11. Influence of hypodermic needle dimensions on subcutaneous injection delivery--a pig study of injection deposition evaluated by CT scanning, histology, and backflow.

    Science.gov (United States)

    Juul, Kezia Ann Praestmark; Bengtsson, Henrik; Eyving, Bente; Kildegaard, Jonas; Lav, Steffen; Poulsen, Mette; Serup, Jørgen; Stallknecht, Bente

    2012-11-01

    Thinner and shorter needles for subcutaneous administration are continuously developed. Previous studies have shown that a thinner needle causes fewer occurrences of painful needle insertions and that a shorter needle decreases the occurrence of painful intramuscular injections. However, little is known about local drug delivery in relation to needle length and thickness. This study aimed to compare deposition depth and backflow from three hypodermic needles of 3 mm 34G (0.19 mm), 5 mm 32G (0.23 mm), and 8 mm 30G (0.30 mm) in length and thickness. Ex vivo experiments were carried out on pigs, in neck tissue comparable to human skin at typical injection sites. Six pigs were included and a total of 72 randomized injections were given, i.e. 24 subcutaneous injections given with each needle type. Accordingly, 400 μL was injected including 70% NovoRapid(®) (Novo Nordisk A/S, Bagsvμrd, Denmark) and 30% Xenetix(®) (Guerbet, Villepinte, France) contrast including 1 mg/mL Alcian blue. Surgical biopsies of injection sites were sampled and computer topographic (CT)-scanned in 3D to assess deposition and local distribution. Biopsies were prepared and stained to evaluate deposition in comparison to the CT-scanning findings. The backflow of each injection was collected with filter paper. The blue stains of filter paper were digitized and volume estimated by software calculation vs. control staining. CT-scanning (n = 57) and histology (n = 10) showed that, regardless of injection depth, the bulk of the injection was in the subcutaneous tissue and did not propagate from subcutis into dermis. With the 8 mm 30G needle all injections apart from one intramuscular injection were located in the subcutaneous layer. The volume depositions peaked in 4-5 mm depth for the 3 mm 34G needle, in 5-6 mm depth for the 5 mm 32G needle, and in 9-10 mm depth for the 8 mm 30G needle. In general, injection depositions evaluated by histology and CT-scans compared well for the individual biopsies

  12. Carrier doping by current injection into LaOFFeAs

    Energy Technology Data Exchange (ETDEWEB)

    Lazareva, Irina; Koval, Yury; Steiner, Christian; Mueller, Paul [Department of Physics, Universitaet Erlangen (Germany); Wurmehl, Sabine; Buechner, Bernd [IFW Dresden (Germany); Stuerzer, Tobias; Johrendt, Dirk [Department Chemie, LMU Muenchen (Germany)

    2013-07-01

    Recently, we were able to change the carrier concentration of hole-doped high-T{sub c} superconductors by injection of large currents along the c-axis. We extend this type of experiments to electron-doped pnictides. From our earlier interpretation we should expect that trapping of electrons caused by current injection would decrease the available carrier concentration. Indeed, by various experiments with superconductors from the LaO{sub 1-x}F{sub x}FeAs family we are able to show that trapped electrons caused by current injection perpendicular to the FeAs planes decrease the carrier concentration. We present a spectacular confirmation of this interpretation by the T{sub c} increase by more than 15 K in heavily overdoped La{sub 0.74}F{sub 0.26}FeAs. We performed similar experiments with the recently discovered 1048 layered pnictides of the composition Ca{sub 10}(FeAs){sub 10}(Pt{sub 4}As{sub 8}). The general tendency of carrier doping by trapped electrons was confirmed. A rather interesting discovery was the evolution of hysteretic c-axis IV-characteristics. This is a strong indication of intrinsic Josephson effects. We discuss these results in terms of a change of anisotropy by carrier doping.

  13. Permeable Steel and Its Application in Plastic-injection Mould

    Institute of Scientific and Technical Information of China (English)

    ZHOU Zhaoyao; CAO Wenjiong; WU Zhengqiang; YU Minqiang; LI Yuanyuan

    2010-01-01

    The gas in plastics mould has great influence on performance, appearance and lifespan of the injection molded parts. Venting channel and its appendix system should be used for gas exhausting in general. However, the dependence on the venting system complicates the mould design. Furthermore in certain condition, it is difficult to integrate the venting system into the mould. Currently a kind of mold material which has gas permeability has been developed in abroad, but the applications of this mold material were restricted by its higher cost and smaller size. In this research, a porous material which was made by powder metallurgy was applied to plastic mould to replace the venting system. Permeability of the steel with different secondary processing was tested and compared with a special apparatus. The metallographic samples of the steel with different secondary processing were prepared and investigated. Finally an actual injection set was established to investigate the applications of permeable steel. The metallographies indicate that the micro-holes inside permeable steel were interconnected. Moulds made of permeable steel exhibit good permeability in the plastic-injection experiments and gas generated in the mould cavity was smoothly exhausted. The melted plastic did not penetrate into the mould or block in the micro-holes. After several times of plastic-injection experiments, the mould still retained good permeability. The strength of this permeable steel is between 200-250 MPa and suitable for industrial applications. The venting systems simplified by permeable steel in plastic-injection have simple structures, which can be applied into any place that requires gas exhausting.

  14. Multi-turn injection of 50 MeV protons into the CERN Proton Synchrotron booster

    CERN Document Server

    Raginel, V; Carli, C; Mikulec, B

    2013-01-01

    Since 1978, Linac2 produces beams of 50 MeV protons with a current around 160 mA, which are injected into the CERN Proton Synchrotron Booster (PSB) with conventional multi-turn injection using a horizontal septum. It is planned to replace Linac2 during a future long stop with a new H- linac, Linac4, injecting at higher energy (160 MeV) and making use of the modern chargeexchange injection principle. Due to the age of Linac2 and to a delicate vacuum situation the risk of a serious Linac2 breakdown has to be considered. Therefore it is necessary to study if the PSB could produce beams useful for the LHC and other experiments injecting a Linac4 proton beam at 50 MeV with much lower average current compared to Linac2 and without the need for a long installation of the 160 MeV H- injection hardware. Benchmarking of the PSB injection model with the existing injection system with Linac2 using the ORBIT code has been done for a LHC-type beam and then the injection model was used to estimate the brightness for LHC-typ...

  15. Multi-turn injection of 50 MeV protons into the CERN Proton Synchrotron Booster

    CERN Document Server

    Raginel, V; Carli, C; Mikulec, B

    2013-01-01

    Since 1978, Linac2 produces beams of 50 MeV protons with a current around 160 mA, which are injected into the CERN Proton Synchrotron Booster (PSB) with conventional multi-turn injection using a horizontal septum. It is planned to replace Linac2 during a future long stop with a new H- linac, Linac4, injecting at higher energy (160 MeV) and making use of the modern chargeexchange injection principle. Due to the age of Linac2 and to a delicate vacuum situation the risk of a serious Linac2 breakdown has to be considered. Therefore it is necessary to study if the PSB could produce beams useful for the LHC and other experiments injecting a Linac4 proton beam at 50 MeV with much lower average current compared to Linac2 and without the need for a long installation of the 160 MeV H- injection hardware. Benchmarking of the PSB injection model with the existing injection system with Linac2 using the ORBIT code has been done for a LHC-type beam and then the injection model was used to estimate the brightness for LHC-typ...

  16. Recognition of and steps to mitigate anxiety and fear of pain in injectable diabetes treatment.

    Science.gov (United States)

    Kruger, Davida F; LaRue, Susan; Estepa, Phil

    2015-01-01

    Injectable treatments, such as glucagon-like peptide-1 receptor agonists and insulin, are options for the pharmacologic treatment of type 2 diabetes. Numerous barriers lead to delay in initiating injectable treatment, which, in turn, may lead to inadequate glycemic control and increased risk of diabetes-related complications, underscoring the need to understand and address these barriers. Barriers to the initiation of injectable therapy, strategies to mitigate barriers, and information about needle attributes and their relation to needle pain are reviewed on the basis of published literature retrieval and our clinical experience. Barriers to the initiation of injectable therapy originate from both patients and practitioners. Anxiety about and fear of injection-associated pain has been estimated to affect approximately 30%-50% of patients before the initiation of diabetes education interventions. Advances in needle design have minimized the pain associated with injections, and recent data suggest that actual pain and bleeding associated with various needle gauges (21-gauge to 31-gauge) are mild. Other barriers include concerns about the ability to handle injectable therapy, concerns about treatment side effects, and impacts on quality of life. Practitioners can help to mitigate barriers to injectable treatment for type 2 diabetes by understanding patient perceptions, improving education, and setting realistic expectations about therapy. Strategies for minimizing injection-associated fear and anxiety include a combination of assessment, appropriate needle selection, patient education, behavioral interventions, and monitoring.

  17. Non-fatal cocaine overdose among injecting and non-injecting cocaine users in Sydney, Australia.

    Science.gov (United States)

    Kaye, Sharlene; Darke, Shane

    2004-10-01

    To investigate the frequency of non-fatal cocaine overdose, and responses to overdoses, among injecting and non-injecting cocaine users. Cross-sectional study. Sydney, Australia. Two hundred current cocaine users. Structured interview. Thirteen per cent of the sample had overdosed on cocaine, 7% in the preceding 12 months. Cocaine injectors were more likely to have overdosed, both ever (17 v 6%) and in the preceding 12 months (9 v 3%). The most common symptoms of overdose were palpitations (68%), intense sweating (44%) and seizures (40%). The use of other drugs in combination with cocaine prior to the most recent overdose was prevalent (64%), most commonly opioids (40%), alcohol (24%) and cannabis (24%). Those who had overdosed were more likely to be female, had longer cocaine use careers, had used more cocaine in the preceding month and preceding 6 months, had higher levels of cocaine dependence and more extensive polydrug use. Twenty-four per cent had witnessed a cocaine overdose, 13% in the preceding 12 months. Injectors were more likely to have witnessed overdoses, both ever (35% v 8%) and in the preceding 12 months (20% v 3%). Experience of, and exposure to, overdose were not rare events. Cocaine users need to be aware of the possibility and nature of overdose, and that cocaine overdose can occur irrespective of method of use. There is a need to emphasise the potential danger of combining cocaine with other drugs.

  18. Forum for injection techniques, India: The first Indian recommendations for best practice in insulin injection technique

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2012-01-01

    Full Text Available Advances in the treatment of diabetes have led to an increase in the number of injectable therapies, such as human insulin, insulin analogues, and glucagon-like peptide-1 analogues. The efficacy of injection therapy in diabetes depends on correct injection technique, among many other factors. Good injection technique is vital in achieving glycemic control and thus preventing complications of diabetes. From the patients′ and health-care providers′ perspective, it is essential to have guidelines to understand injections and injection techniques. The abridged version of the First Indian Insulin Injection technique guidelines developed by the Forum for Injection Technique (FIT India presented here acknowledge good insulin injection techniques and provide evidence-based recommendations to assist diabetes care providers in improving their clinical practice.

  19. Injectable biomaterials: a perspective on the next wave of injectable therapeutics.

    Science.gov (United States)

    Spector, Myron; Lim, Teck Chuan

    2016-02-02

    We are experiencing a new wave of injectable therapeutics (namely/injectable biomaterials) to complement injectable drugs and injectable biologics, and to serve as the basis for injectable combinatorial therapeutics. Injectable biomaterials contribute to the treatment of the fluid-filled defects which often result from disease and injury, by providing the missing physical framework (i.e. the stroma). However, while injectable matrices may be necessary for the successful treatment of certain lesions, they will not likely be sufficient. Chemoattractants for select endogenous cells, or cells themselves, may need to be incorporated into the matrix prior to its injection to ensure the necessary cellular repopulation of the cavitary defect. These agents and others (drugs and biologics) delivered by the matrix represent the new category of injectable combinatorial therapeutics.

  20. Examination of injection moulded thermoplastic maize starch

    Directory of Open Access Journals (Sweden)

    2007-12-01

    Full Text Available This paper focuses on the effect of the different injection moulding parameters and storing methods on injection moulded thermoplastic maize starch (TPS. The glycerol and water plasticized starch was processed in a twin screw extruder and then with an injection moulding machine to produce TPS dumbbell specimens. Different injection moulding set-ups and storing conditions were used to analyse the effects on the properties of thermoplastic starch. Investigated parameters were injection moulding pressure, holding pressure, and for the storage: storage at 50% relative humidity, and under ambient conditions. After processing the mechanical and shrinkage properties of the manufactured TPS were determined as a function of the ageing time. While conditioning, the characteristics of the TPS changed from a soft material to a rigid material. Although this main behaviour remained, the different injection moulding parameters changed the characteristics of TPS. Scanning electron microscope observations revealed the changes in the material on ageing.

  1. Resin injection in clays with high plasticity

    Science.gov (United States)

    Nowamooz, Hossein

    2016-11-01

    Regarding the injection process of polyurethane resins in clays with high plasticity, this paper presents the experimental results of the pressuremeter and cone penetration tests before and after injection. A very important increase in pressure limit or in soil resistance can be observed for all the studied depths close to the injection points. An analytical analysis for cylindrical pore cavity expansion in cohesive frictional soils obeying the Mohr-Coulomb criterion was then used to reproduce the pressuremeter tests before and after injection. The model parameters were calibrated by maintaining constant the elasticity parameters as well as the friction angel before and after injection. A significant increase in cohesion was observed because of soil densification after resin expansion. The estimated undrained cohesions, derived from the parameters of the Mohr-Coulomb criterion, were also compared with the cone penetration tests. Globally, the model predictions show the efficiency of resin injection in clay soils with high plasticity.

  2. Injectable Corticosteroids: Take Precautions and Use Caution.

    Science.gov (United States)

    Freire, Véronique; Bureau, Nathalie J

    2016-11-01

    Corticosteroids are routinely injected into soft tissues, tendon sheaths, bursae, and joints. These anti-inflammatory agents have different potency and solubility, and solubility is inversely correlated with the duration of action. Corticosteroids carry a low risk of complications but commonly cause systemic and local adverse effects. The use of intra-articular corticosteroid injections in the treatment of inflammatory arthritis and osteoarthritis is well established. Evidence also supports the use of injectable corticosteroids in the treatment of inflammatory tenosynovitis and bursitis associated with rheumatic diseases, trigger finger and de Quervain disease, and carpal tunnel syndrome. The role of corticosteroid injections in the management of rotator cuff disease remains unclear. Strong scientific evidence indicates that corticosteroid injections for lateral epicondylosis worsen the long-term outcomes of patients. This review article discusses the considerations related to the use of corticosteroid injections in the management of nonspinal musculoskeletal conditions.

  3. Deltoid injections of risperidone long-acting injectable in patients with schizophrenia.

    Science.gov (United States)

    Quiroz, Jorge A; Rusch, Sarah; Thyssen, An; Palumbo, Joseph M; Kushner, Stuart

    2011-06-01

    Risperidone long-acting injectable was previously approved for treatment of schizophrenia as biweekly injections in the gluteal muscle only. We present data on local injection-site tolerability and safety of risperidone long-acting injectable and comparability of systemic exposure of deltoid versus gluteal injections. Risperidone long-acting injectable was administered in an open-label, single-dose, two-way crossover study, with patients randomized to receive either 25mg gluteal/37.5mg deltoid crossover in two treatment periods or 50mg gluteal/50mg deltoid injections crossover; each treatment period was separated by an 85-day observation period (Study 1) and an open-label, multiple-dose study (4 sequential 37.5mg or 50mg deltoid injections every 2 weeks) (Study 2). The pharmacokinetic results from both the studies have already been published. In Study 1 (n=170), the majority of patients had no local injection-site findings, based on investigator and patient-rated evaluations. In Study 2 (n=53), seven of the 51 patients who received at least two deltoid injections discontinued (primary endpoint). However, none of the discontinuations were due to injection-site related reasons. The 90-percent upper confidence limit of the true proportion of injection-site issue withdrawals was 5.7 percent. No moderate or severe injection-site reactions were reported. Intramuscular injections via the deltoid and gluteal sites are equivalent routes of administration of risperidone long-acting injectable with respect to local injection-site tolerability. The overall safety and tolerability profile of risperidone long-acting injectable was comparable when administered as an intramuscular injection in the deltoid (37.5mg and 50mg) and gluteal (25mg and 50mg) sites.

  4. Intracerebroventricular leptin injection affects neuroendocrine reproductive axis in ovariectomized rats

    Institute of Scientific and Technical Information of China (English)

    Yuebing Qiao; Huixian Cui

    2008-01-01

    BACKGROUND: Leptin regulates neuroendocrine function of the hypothalamus-pituitary-ovary axis in humans.OBJECTIVE: To verify effects of intracerebroventricular leptin injection on neuroendocrine function of the hypothalamus-pituitary-ovary axis in nvariectomized rats.DESIGN, TIME AND SETTING: A randomized, controlled experiment was performed at the Basic Medical Institute, Chengde Medical College between June and October 2007.MATERIALS: Thirty healthy, female, Wistar rats were included in this study. The following compounds were used: leptin; gonadotropin-releasing hormone (GnRH) and luteinizing hormone (LH) enzyme-linked immunosorbent assay kits.METHODS: Rats were randomly divided into 3 groups at 1, 2, and 4 hours after injection. Each group was subdivided into control and experimental groups (n = 5 animals per group and time point). All rats were subjected to bilateral ovariectomy and, beginning on day 7 after surgery, animals received daily subcutaneous injections of estradiol benzoate (2 μ g) for 7 consecutive days. The experimental groups were injected with 5 μ L leptin (1 g/L) into the lateral cerebral ventricle, and control groups received an equal volume of physiological saline.MAIN OUTCOME MEASURES: GnRH and LH secretion were examined 1, 2, and 4 hours after injection using GnRH and LH ELISA kits, respectively.RESULTS: In the experimental groups, GnRH secretion significantly increased (P < 0.01), followed by LH secretion (P < 0.01), compared with the control groups. GnRH secretion significantly increased l hour after leptin injection (P < 0.01). The LH increase was less pronounced, but still significant (P < 0.01); however,the most prominent LH increase occurred between 1 and 2 hours. Both GnRH and LH secretion reached peak levels at 2 hours after leptin injection. Thereafter, both GnRH and LH secretion decreased, but still maintained very high levels, compared with the control group (P < 0.01).CONCLUSION: lntracerebroventricular leptin injection

  5. Optical injection in semiconductor ring lasers

    CERN Document Server

    Coomans, W; Van der Sande, G; Gelens, L; Danckaert, J; 10.1103/PhysRevA.81.033802

    2011-01-01

    We theoretically investigate optical injection in semiconductor ring lasers and disclose several dynamical regimes. Through numerical simulations and bifurcation continuation, two separate parameter regions in which two different injection-locked solutions coexist are revealed, in addition to a region in which a frequency-locked limit cycle coexists with an injection-locked solution. Finally, an antiphase chaotic regime without the involvement of any carrier dynamics is revealed. Parallels are drawn with the onset of chaos in the periodically forced Duffing oscillator.

  6. Waterflooding injectate design systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Brady, Patrick V.; Krumhansl, James L.

    2016-12-13

    A method of recovering a liquid hydrocarbon using an injectate includes recovering the liquid hydrocarbon through primary extraction. Physico-chemical data representative of electrostatic interactions between the liquid hydrocarbon and the reservoir rock are measured. At least one additive of the injectate is selected based on the physico-chemical data. The method includes recovering the liquid hydrocarbon from the reservoir rock through secondary extraction using the injectate.

  7. Autologous Fat Injection for Augmented Mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Eul Sik; Seo, Bo Kyoung; Yi, Ann; Cho, Kyu Ran [Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2008-12-15

    Autologous fat injection is one of the methods utilized for augmented mammoplasty methods. In this surgical procedure, the fat for transfer is obtained from the donor site of the patient's own body by liposuction and the fat is then injected into the breast. We report here cases of three patients who underwent autologous fat injection. Two of the patients had palpable masses that were present after surgery. The serial imaging findings and surgical method of autologous fat transfer are demonstrated

  8. INJECTION CHOICE FOR SPALLATION NEUTRON SOURCE RING.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; BEEBE-WANG,J.; BLASKIEWICZ,M.; BRODOWSKI,J.; FEDOTOV,A.; GARDNER,C.; LEE,Y.Y.; RAPARIA,D.; DANILOV,V.; HOLMES,J.; PRIOR,C.; REES,G.; MACHIDA,S.

    2001-06-18

    Injection is key in the low-loss design of high-intensity proton facilities like the Spallation Neutron Source (SNS). During the design of both the accumulator and the rapid-cycling-synchrotron version of the SNS, extensive comparison has been made to select injection scenarios that satisfy SNS's low-loss design criteria. This paper presents issues and considerations pertaining to the final choice of the SNS injection systems.

  9. Horizontal high-pressure air injection well construction and operation

    Energy Technology Data Exchange (ETDEWEB)

    Hume, J. [Continental Resources Inc., ND (United States)

    2005-07-01

    This paper discussed the design and operational challenges of a horizontal high-pressure air injection well currently in use at the Cedar Hill Red River B field in North Dakota. The field was developed in 1994, using horizontal wells oriented from the northeast to the southwest corners of each section on 640 acre spacing. In March of 2001, the field was unitized resulting in a horizontal waterflood project and a 320 acre horizontal high pressure air injection project. Extreme temperatures and pressures occurring in the reservoir from the combustion processes associated with high pressure air injection have resulted in several challenges. Reservoir and fluid properties of the field were presented, as well as a type log. Details of the Buffalo and Cedar Hills field were also provided, with a comparison of horizontal and vertical patterns. A light oil displacement process was reviewed, with details of tubing leak corrosion, packer seal and detonation failures. Burn front exposure to casing was discussed, and a wellbore diagram was provided. Various horizontal conversions were discussed. A description of the Cedar Hills Compressor Station and compression trains was provided. It was concluded that knowledge gained from 25 years of vertical high pressure air injection experience has been successfully incorporated to create a safe and durable design. 1 tab., 16 figs.

  10. Performance of CO2 enrich CNG in direct injection engine

    Science.gov (United States)

    Firmansyah, W. B.; Ayandotun, E. Z.; Zainal, A.; Aziz, A. R. A.; Heika, M. R.

    2015-12-01

    This paper investigates the potential of utilizing the undeveloped natural gas fields in Malaysia with high carbon dioxide (CO2) content ranging from 28% to 87%. For this experiment, various CO2 proportions by volume were added to pure natural gas as a way of simulating raw natural gas compositions in these fields. The experimental tests were carried out using a 4-stroke single cylinder spark ignition (SI) direct injection (DI) compressed natural gas (CNG) engine. The tests were carried out at 180° and 300° before top dead centre (BTDC) injection timing at 3000 rpm, to establish the effects on the engine performance. The results show that CO2 is suppressing the combustion of CNG while on the other hand CNG combustion is causing CO2 dissociation shown by decreasing CO2 emission with the increase in CO2 content. Results for 180° BTDC injection timing shows higher performance compared to 300° BTDC because of two possible reasons, higher volumetric efficiency and higher stratification level. The results also showed the possibility of increasing the CO2 content by injection strategy.

  11. Experimental Investigations of Micro Air Injection to Control Rotating Stall

    Institute of Scientific and Technical Information of China (English)

    Chaoqun Nie; Zhiting Tong; Shaojuan Geng; Junqiang Zhu; Weiguang Huang

    2007-01-01

    Steady discrete micro air injection at the tip region in front of the first compressor rotor has been proved to be an effective method to delay the inception of rotating stall in a low speed axial compressor. Considering the practical application a new type of micro injector was designed and described in this paper, which was imbedded in the casing and could be moved along the chord. In order to verify its feasibility to other cases, such as high subsonic axial compressor or centrifugal compressor, some other cases have been studied. Experimental results of the same low speed axial compressor showed that the new injector could possess many other advantages besides successfully stabilizing the compressor. Experiments performed on a high subsonic axial compressor confirmed the effectiveness of micro air injection when the relative velocity at the blade tip is high subsonic. Meanwhile in order to explore its feasibility in centrifugal compressor, a similar micro injector was designed and tested on a low speed centrifugal compressor with vaned diffuser. The injected mass flow was a bit larger than that used in axial compressors and the results showed micro injection could also delay the onset of rotating stall in the centrifugal compressor.

  12. Turbulent acidic jets and plumes injected into an alkaline environment

    Science.gov (United States)

    Ulpre, Hendrik

    2012-11-01

    The characteristics of a strong acidic turbulent jet or plume injected into an alkaline environment comprising of a weak/strong base are examined theoretically and experimentally. A chemistry model is developed to understand how the pH of a fluid parcel of monoprotic acid changes as it is diluted and reacts with the ambient fluid. A standard fluid model, based on a top-hat model for acid concentration and velocity is used to express how the dilution of acid varies with distance from the point of discharge. These models are applied to estimate the point of neutralisation and the travel time with distance within the jet/plume. An experimental study was undertaken to test the theoretical results. These experiments involved injecting jets or vertical plumes of dilute nitric acid into a large tank containing a variety of base salts dissolved in water. The injected fluid contained litmus indicator dye which showed a change in colour from red to blue close to the point of neutralisation. In order to obtain a range of neutralisation distances, additional basic salts were added to the water to increase its pH buffering capacity. The results are applied to discuss the environmental implications of an acidic jet/plume injected into the sea off the South East coast of Great Britain.

  13. Optimization of somatic cell injection in the perspective of nuclear transfer in goldfish

    Directory of Open Access Journals (Sweden)

    Mahe Sophie

    2010-06-01

    Full Text Available Abstract Background Nuclear transfer has the potential to become one strategy for fish genetic resources management, by allowing fish reconstruction from cryopreserved somatic cells. Survival rates after nuclear transfer are still low however. The part played by unsuitable handling conditions is often questioned, but the different steps in the procedure are difficult to address separately. In this work led on goldfish (Carassius auratus, the step of somatic cells injection was explored. Non-enucleated metaphase II oocytes were used as a template to explore the toxicity of the injection medium, to estimate the best location where the cell should be injected, and to assess the delay necessary between cell injection and oocyte activation. Results Trout coelomic fluid was the most suitable medium to maintain freshly spawned oocytes at the metaphase II stage during oocyte manipulation. Oocytes were then injected with several media to test their toxicity on embryo development after fertilization. Trout coelomic fluid was the least toxic medium after injection, and the smallest injected volume (10 pL allowed the same hatching rates as the non injected controls (84.8% ± 23. In somatic cell transfer experiments using non enucleated metaphase II oocytes as recipient, cell plasma membrane was ruptured within one minute after injection. Cell injection at the top of the animal pole in the oocyte allowed higher development rates than cell injection deeper within the oocyte (respectively 59% and 23% at mid-blastula stage. Embryo development rates were also higher when oocyte activation was delayed for 30 min after cell injection than when activation was induced without delay (respectively 72% and 48% at mid-blastula stage. Conclusions The best ability of goldfish oocytes to sustain embryo development was obtained when the carrier medium was trout coelomic fluid, when the cell was injected close to the animal pole, and when oocyte activation was induced 30 min

  14. [Intra-articular injection of cortisone].

    Science.gov (United States)

    Hammer, M; Schwarz, T; Ganser, G

    2015-11-01

    Intra-articular injections with glucocorticoids are standard procedures according to therapy guidelines in many rheumatic conditions. There is increasing evidence from clinical trials on the treatment of rheumatoid arthritis that more patients will attain the target of remission using a combination of systemic medication and intra-articular injections with glucocorticoids compared to systemic medication alone. Intra-articular injections with glucocorticoids play an important role in the therapeutic management of pediatric rheumatic diseases. In many countries competency in performing intra-articular injections is among the important skills necessary for certification as a specialist in rheumatology.

  15. DC injection into low voltage AC networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  16. Pharmacokinetics of zinc tannate after intratesticular injection.

    Science.gov (United States)

    Migally, N B; Fahim, M S

    1984-01-01

    Forty-eight sexually mature male rats were injected intratesticularly with either 1, 3, or 6 mg zinc tannate (Kastrin) or with saline (as control). Zinc localized only in low concentration in primary spermatocytes and could not be detected in spermatogonia, Sertoli cells, spermatids, or spermatozoa. Forty-eight hours after injection of 1 mg Kastrin, zinc was accumulated in the spermatogonia and primary spermatocytes while, after injection of 3 mg, zinc was preferentially localized in Sertoli cells and spermatids; however, zinc was observed in the spermatids and spermatozoa 48 h after injection with 6 mg, and germ cells lost their identity and were fragmented after 1 week.

  17. Precision injection molding of freeform optics

    Science.gov (United States)

    Fang, Fengzhou; Zhang, Nan; Zhang, Xiaodong

    2016-08-01

    Precision injection molding is the most efficient mass production technology for manufacturing plastic optics. Applications of plastic optics in field of imaging, illumination, and concentration demonstrate a variety of complex surface forms, developing from conventional plano and spherical surfaces to aspheric and freeform surfaces. It requires high optical quality with high form accuracy and lower residual stresses, which challenges both optical tool inserts machining and precision injection molding process. The present paper reviews recent progress in mold tool machining and precision injection molding, with more emphasis on precision injection molding. The challenges and future development trend are also discussed.

  18. Nicolau Syndrome after Intramuscular Injection: 3 Cases

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-05-01

    Full Text Available Nicolau syndrome is a rare complication of intramuscular injection consisting of ischemic necrosis of skin, soft tissue, and muscular tissue that arises locoregionally. The characteristic pattern is pain around the injection site, developing into erythema, a livedoid dermatitis patch, and necrosis of the skin, subcutaneous fat, and muscle tissue. Three patients were injected with drugs (diclofenac sodium, ketoprofen, meperidine for pain relief. Three patients complained of pain, and a skin lesion was observed, after which necrosis developed on their buttocks. Each patient underwent debridement and coverage. The wound healed uneventfully. We report three cases of Nicolau syndrome in the buttocks following diclofenac intramuscular injection.

  19. Charge Injection and Transport in Organic Nanofibers

    DEFF Research Database (Denmark)

    Kjelstrup-Hansen, Jakob; Bøggild, Peter; Rubahn, H. G.

    2007-01-01

    We investigate the carrier injection and transport in individual para-hexaphenylene nanofibers by electrical transport measurements at different temperatures. The injected current shows much weaker temperature dependence than what would be anticipated from a simplistic model that considers...... the injection barrier height equal to the difference between the metal electrode work function and the HOMO energy level of the organic semiconductor. Semiquantitative modeling suggests that the weak temperature dependence is due to injection into a distribution of states rather than into a single energy level...

  20. Subdural injection: report of two cases

    Directory of Open Access Journals (Sweden)

    Cadavid-Puentes, Adriana

    2016-10-01

    Full Text Available Two cases are reported of accidental subdural injection during epidural procedures for pain control. The first one was a man with chronic lumbar pain who suffered such complication during an epidural injection of steroids using the interlaminar approach. The second one was a woman with intracranial hypotension syndrome who required the application of an epidural blood patch in order to control multiple CSF fistulae. The procedure had to be aborted twice due to the subdural pattern observed after injection of the contrast medium. Accidental subdural block is a rare complication of epidural injection for analgesic or anesthetic procedures.

  1. An Innovative Needle-free Injection System: Comparison to 1 ml Standard Subcutaneous Injection.

    Science.gov (United States)

    Kojic, Nikola; Goyal, Pragun; Lou, Cheryl Hamer; Corwin, Michael J

    2017-05-01

    A needle-free delivery system may lead to improved satisfaction and compliance, as well as reduced anxiety among patients requiring frequent or ongoing injections. This report describes a first-in-man assessment comparing Portal Instruments' innovative needle-free injection system with subcutaneous injections using a 27G needle. Forty healthy volunteer participants each received a total of four injections of 1.0 mL sterile saline solution, two with a standard subcutaneous injection using a 27G needle, and two using the Portal injection system. Perception of pain was measured using a 100-mm visual analog scale (VAS). Injection site reactions were assessed at 2 min and at 20-30 min after each injection. Follow-up contact was made 24-48 h after the injections. Subject preference regarding injection type was also assessed. VAS pain scores at Portal injection sites met the criteria to be considered non-inferior to the pain reported at 27G needle injection sites (i.e., upper 95% confidence bound less than +5 mm). Based on a mixed effects model, at time 0, accounting for potential confounding variables, the adjusted difference in VAS scores indicated that Portal injections were 6.5 mm lower than the 27G needle injections (95% CI -10.5, -2.5). No clinically important adverse events were noted. Portal injections were preferred by 24 (60%) of the subjects (P = 0.0015). As an early step in the development of this new needle-free delivery system, the current study has shown that a 1.0-mL saline injection can be given with less pain reported than a standard subcutaneous injection using a 27G needle.

  2. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections.

    Science.gov (United States)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind; Sparre, Thomas; Madsen, Nils Berg; Kildegaard, Jonas

    2016-07-01

    After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. Leakage data were obtained from a post hoc analysis of clinical trial data and from a pig study. Data from the clinical study were used to determine leakage as a function of injection volume, speed and region. Data from the pig study were used to determine leakage as a function of needle wall thickness, needle taper, injection angle, and wait time from end of injection to withdrawal of needle from skin. Leakage volume was positively related to injection volume. Injections in the abdomen caused less leakage than thigh injections. A 32G needle caused less leakage than a 31G and a 32G tip (tapered) needle, and a "straight in" 90° needle insertion angle caused less leakage than an angled (~45°) insertion. Wait times of minimum 3 seconds caused less leakage than immediate withdrawal of the needle after injection. Needle wall thickness and injection speed did not influence leakage. Leakage will be minimized using a thin needle, using 90° needle insertion in the abdomen, injecting maximum 800 µL at a time, and waiting at least 3 seconds after the injection until the needle is withdrawn from the skin. © 2016 Diabetes Technology Society.

  3. Ethanol injection of ornamental trees facilitates testing insecticide efficacy against ambrosia beetles (Coleoptera: Curculionidae: Scolytinae).

    Science.gov (United States)

    Reding, Michael E; Oliver, Jason B; Schultz, Peter B; Ranger, Christopher M; Youssef, Nadeer N

    2013-02-01

    Exotic ambrosia beetles are damaging pests in ornamental tree nurseries in North America. The species Xylosandrus crassiusculus (Motshulsky) and Xylosandrus germanus (Blandford) are especially problematic. Management of these pests relies on preventive treatments of insecticides. However, field tests of recommended materials on nursery trees have been limited because of unreliable attacks by ambrosia beetles on experimental trees. Ethanol-injection of trees was used to induce colonization by ambrosia beetles to evaluate insecticides and botanical formulations for preventing attacks by ambrosia beetles. Experiments were conducted in Ohio, Tennessee, and Virginia. Experimental trees injected with ethanol had more attacks by ambrosia beetles than uninjected control trees in all but one experiment. Xylosandrus crassiusculus and X. germanus colonized trees injected with ethanol. In most experiments, attack rates declined 8 d after ethanol-injection. Ethanol-injection induced sufficient pressure from ambrosia beetles to evaluate the efficacy of insecticides for preventing attacks. Trunk sprays of permethrin suppressed cumulative total attacks by ambrosia beetles in most tests. Trunk sprays of the botanical formulations Armorex and Veggie Pharm suppressed cumulative total attacks in Ohio. Armorex, Armorex + Permethrin, and Veggie Pharm + Permethrin suppressed attacks in Tennessee. The bifenthrin product Onyx suppressed establishment of X. germanus in one Ohio experiment, and cumulative total ambrosia beetle attacks in Virginia. Substrate drenches and trunk sprays of neonicotinoids, or trunk sprays of anthranilic diamides or tolfenpyrad were not effective. Ethanol-injection is effective for inducing attacks and ensuring pressure by ambrosia beetles for testing insecticide efficacy on ornamental trees.

  4. Ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a hot strongly magnetized plasma

    CERN Document Server

    Liu, Wei

    2010-01-01

    We present results from three-dimensional ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a hot strongly magnetized plasma, with the aim of providing insight into core fueling of a tokamak with parameters relevant for ITER (International Thermonuclear Experimental Reactor) and NSTX (National Spherical Torus Experiment). Unmagnetized jet injection is similar to compact toroid injection but with higher possible injection density and total mass, as well as a potentially smaller footprint for the injector hardware. Our simulation results show that the unmagnetized dense jet is quickly magnetized upon injection. The penetration depth of the jet into the tokamak plasma is mostly dependent on the jet's initial kinetic energy while the jet's magnetic field determines its interior evolution. A key requirement for spatially precise fueling is for the jet's slowing-down time to be less than the time for the perturbed tokamak magnetic flux to relax due to magnetic reconnection. Thus ...

  5. FLUKA Simulation of Particle Fluences to ALICE due to LHC Injection Kicker Failures

    CERN Document Server

    Shetty, N V; Di Mauro, A; Lechner, A; Leogrande, E; Uythoven, J

    2014-01-01

    The counter-rotating beams of the LHC are injected in insertion regions which also accommodate the ALICE and LHCb experiments. An assembly of beam absorbers ensures the protection of machine elements in case of injection kicker failures, which can affect either the injected or the stored beam. In the first years of LHC operation, secondary particle showers due to beam impact on the injection beam stopper caused damage to the MOS injectors of the ALICE silicon drift detector as well as high-voltage trips in other ALICE subdetectors. In this study, we present FLUKA [1,2] simulations of particle fluences to the ALICE cavern for injection failures encountered during operation. Two different cases are reported, one where the miskicked beam is fully intercepted and one where the beam grazes the beam stopper.

  6. The function of point injection in improving learning and memory dysfunction caused by cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Chen Hua-De

    2001-02-01

    Full Text Available This experiment has investigated the influence of Yamen (Du. 15 point injection on learning and memory dysfunction caused by cerebral ischemia and reprofusion in bilateral cervical general artery combined with bleeding on mouse tail to mimic vascular dementia in human beings. By dividing 40 mice into 4 groups (group1false operation group, group2model group, group3point injection with Cerebrolysin group4point injection with saline. According to random dividing principles, we observed the influence of Yamen(Du. 15 point injection on the time of swimming the whole course used by model mice which had received treatment for different days in different groups, and the influence of those mice on wrong times they entered blind end. The result showed that point injection with Cerebrolysin and saline could improve learning and memory dysfunction of the mice caused by cerebral ischemia.

  7. The self-injection threshold in self-guided laser wakefield accelerators

    CERN Document Server

    Mangles, Stuart P D; Bloom, Michael S; Burza, Matthias; Najmudin, Zulfikar; Persson, Anders; Svensson, Kristoffer; Thomas, Alexander G R; Wahlstrom, Claes-Goran

    2012-01-01

    A laser pulse traveling through a plasma can excite large amplitude plasma waves that can be used to accelerate relativistic electron beams in a very short distance---a technique called laser wakefield acceleration. Many wakefield acceleration experiments rely on the process of wavebreaking, or self-injection, to inject electrons into the wave, while other injection techniques rely on operation without self-injection. We present an experimental study into the parameters, including the pulse energy, focal spot quality and pulse power, that determine whether or not a wakefield accelerator will self-inject. By taking into account the processes of self-focusing and pulse compression we are able to extend a previously described theoretical model, where the minimum bubble size required for trapping is not constant but varies slowly with density and find excellent agreement with this model.

  8. Magnetized plasma flow injection into tokamak and high-beta compact torus plasmas

    Science.gov (United States)

    Matsunaga, Hiroyuki; Komoriya, Yuuki; Tazawa, Hiroyasu; Asai, Tomohiko; Takahashi, Tsutomu; Steinhauer, Loren; Itagaki, Hirotomo; Onchi, Takumi; Hirose, Akira

    2010-11-01

    As an application of a magnetized coaxial plasma gun (MCPG), magnetic helicity injection via injection of a highly elongated compact torus (magnetized plasma flow: MPF) has been conducted on both tokamak and field-reversed configuration (FRC) plasmas. The injected plasmoid has significant amounts of helicity and particle contents and has been proposed as a fueling and a current drive method for various torus systems. In the FRC, MPF is expected to generate partially spherical tokamak like FRC equilibrium by injecting a significant amount of magnetic helicity. As a circumstantial evidence of the modified equilibrium, suppressed rotational instability with toroidal mode number n = 2. MPF injection experiments have also been applied to the STOR-M tokamak as a start-up and current drive method. Differences in the responses of targets especially relation with beta value and the self-organization feature will be studied.

  9. Numerical study of rotating detonation engine with an array of injection holes

    Science.gov (United States)

    Yao, S.; Han, X.; Liu, Y.; Wang, J.

    2017-05-01

    This paper aims to adopt the method of injection via an array of holes in three-dimensional numerical simulations of a rotating detonation engine (RDE). The calculation is based on the Euler equations coupled with a one-step Arrhenius chemistry model. A pre-mixed stoichiometric hydrogen-air mixture is used. The present study uses a more practical fuel injection method in RDE simulations, injection via an array of holes, which is different from the previous conventional simulations where a relatively simple full injection method is usually adopted. The computational results capture some important experimental observations and a transient period after initiation. These phenomena are usually absent in conventional RDE simulations due to the use of an idealistic injection approximation. The results are compared with those obtained from other numerical studies and experiments with RDEs.

  10. Self-injection threshold in self-guided laser wakefield accelerators

    Directory of Open Access Journals (Sweden)

    S. P. D. Mangles

    2012-01-01

    Full Text Available A laser pulse traveling through a plasma can excite large amplitude plasma waves that can be used to accelerate relativistic electron beams in a very short distance—a technique called laser wakefield acceleration. Many wakefield acceleration experiments rely on the process of wave breaking, or self-injection, to inject electrons into the wave, while other injection techniques rely on operation without self-injection. We present an experimental study into the parameters, including the pulse energy, focal spot quality, and pulse power, that determine whether or not a wakefield accelerator will self-inject. By taking into account the processes of self-focusing and pulse compression we are able to extend a previously described theoretical model, where the minimum bubble size k_{p}r_{b} required for trapping is not constant but varies slowly with density and find excellent agreement with this model.

  11. Tyrihans SRSWI (subsea raw seawater injection)

    Energy Technology Data Exchange (ETDEWEB)

    Time, Nils Petter

    2010-07-01

    By the summer of 2010, Statoil will have installed and commissioned a 2 x 2.5 MW electrical subsea pump system for injection of seawater on the Tyrihans field. Powered from the Kristin platform, the system will pump untreated water directly from the sea into one well at a rate of 14000 m3/day to achieve an Increased Oil Recovery of 10%. The pump system was designed and delivered by Aker Solutions and interfaces the Tyrihans subsea production system delivered by FMC, a power umbilical from Nexans as well as the Kristin topside facilities. In addition to qualification testing, the SRSWI system underwent extensive system testing, including performance- and long term testing, and function testing of the control system from FMC and Kongsberg Maritime. The subsea modules of the SRSWI system and the power umbilical were installed by Acergy's vessel Scandi Acergy, while the topside transformers and variable speed drives were installed on Kristin by Aker Reinertsen, the topside modifications and hook-up contractor. The many interfaces in this project required close and constructive cooperation between the parties in all phases of the development. This paper summarises the experiences from the project. (Author)

  12. Mechanical instability induced by water weakening in laboratory fluid injection tests

    Science.gov (United States)

    David, C.; Dautriat, J.; Sarout, J.; Delle Piane, C.; Menéndez, B.; Macault, R.; Bertauld, D.

    2015-06-01

    To assess water-weakening effects in reservoir rocks, previous experimental studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks fully saturated either with water or with inert fluids. So far, little attention has been paid to the mechanical behavior during fluid injection under conditions similar to enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behavior of the weakly consolidated Sherwood sandstone in laboratory experiments. Our specimens were instrumented with 16 ultrasonic P wave transducers for both passive and active acoustic monitoring during loading and fluid injection to record the acoustic signature of fluid migration in the pore space and the development of damage. Calibration triaxial tests were conducted on three samples saturated with air, water, or oil. In a second series of experiments, water and inert oil were injected into samples critically loaded up to 80% or 70% of the dry or oil-saturated compressive strength, respectively, to assess the impact of fluid migration on mechanical strength and elastic properties. The fluids were injected with a low back pressure to minimize effective stress variations during injection. Our observations show that creep takes place with a much higher strain rate for water injection compared to oil injection. The most remarkable difference is that water injection in both dry and oil-saturated samples triggers mechanical instability (macroscopic failure) within half an hour whereas oil injection does not after several hours. The analysis of X-ray computed tomography images of postmortem samples revealed that the mechanical instability was probably linked to loss of cohesion in the water-invaded region.

  13. Injectable liquid alkali alloy based-tumor thermal ablation therapy.

    Science.gov (United States)

    Rao, Wei; Liu, Jing

    2009-01-01

    The alkali metal was recently found to be a very useful agent for inducing minimally invasive tumor hyperthermia therapy. However, the solid-like metal makes it somewhat inconvenient to perform the surgery. Here, to overcome this drawback, the NaK alloy in liquid state at room temperature was proposed as a highly efficient thermal ablative agent for tumor treatment. For illustration purposes, the functionalized liquid NaK alloy at a mass ratio 1:1 was obtained and an amount of 0.35 ml was injected into in vitro pork. The sizes of the damage region and temperature response were measured. It was found that significant temperature increase by a magnitude of > 80 degrees C can easily be obtained. This produced a large coagulation and necrotic area within selected areas for in vitro tests and the necrotic region volume is three times that of the NaK injection quantity. Furthermore, for the in vivo experiment, breast EMT6 tumor in mouse was subjected to treatment by NaK alloy. Tumor was harvested after the experiment to assess its viability. Histological section showed complete necrosis at the target site. These conceptual results demonstrate that using injectable liquid alkali alloy to ablate tumor is rather promising. This study also raised interesting issues waiting for clarification in future technical and animal studies aiming to assess efficacy, side effects and safety of the new therapy.

  14. CO2 injection effect on physical properties of greensand from the North Sea

    DEFF Research Database (Denmark)

    Hossain, Zakir; Fabricius, Ida Lykke

    2011-01-01

    into brine saturated samples and flush the CO2 saturated samples with brine at reservoir conditions. Helium porosity, Klinkenberg permeability, and specific surface area (SSA) by BET were measured on dry greensand samples before and after the CO2 experiment. NMR T2 distribution and electrical resistivity...... were measured on brine saturated greensand samples before and after the CO2 experiment. Ultrasonic P-and Swave velocities were measured on brine saturated samples as well as on dry samples. Our laboratory results show that CO2 injection has no major effect on porosity, electrical and elastic properties...... of greensand. The Klinkenberg permeability of greensand increased after CO2 injection. An NMR T2 distribution and NMR permeability modeling approach was tested to evaluate the effect on matrix permeability of CO2 injection. It appears that permeability after CO2 injection increased due to the increase of macro...

  15. 21 CFR 522.2005 - Propofol injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Propofol injection. 522.2005 Section 522.2005 Food... Propofol injection. (a) Specifications. The drug is a sterile, nonpyrogenic, oil-in-water emulsion containing 10 milligrams of propofol per milliliter. (b) Sponsor. See No. 000061 in § 510.600(c) of this...

  16. APPLICATION OF INJECTION TECHNOLOGIES IN METALLURGICAL PRODUCTION

    Directory of Open Access Journals (Sweden)

    S. V. Korneev

    2011-01-01

    Full Text Available Analysis of injection technologies shows that the largest prevalence they got d at application on powerful electric arc furnaces and at out-of-furnace processing of big volumes of metal. at the same time theoretical and experimental basis of using of injection technologies is constantly being replenished with new investigations.

  17. Homicide by intravenous injection of naphtha.

    Science.gov (United States)

    Case, M E; Poklis, A; Mackell, M A

    1985-01-01

    A case of homicide by the intravenous injection of Energine, a petroleum distillate spot remover, is presented. This case is the only known homicide committed with naphtha. This elderly man had severe natural disease in addition to chest trauma sustained in the assault leading to death; however, the rapid injection of approximately 25 mL of Energine was the overwhelming cause of death.

  18. The risk of intraarticular injections are overestimated

    DEFF Research Database (Denmark)

    Asmussen, Rikke; Just, Søren Andreas; Jensen Hansen, Inger Marie

    The risk of intraarticular injections are overestimated. Volume 73, Annals of the Rheumatic Diseases, the EULAR Journal,, June 2014 volume 73, supplement 2, p. 286-87......The risk of intraarticular injections are overestimated. Volume 73, Annals of the Rheumatic Diseases, the EULAR Journal,, June 2014 volume 73, supplement 2, p. 286-87...

  19. Lateral epicondylitis: review of injection therapies.

    Science.gov (United States)

    Judson, Christopher H; Wolf, Jennifer Moriatis

    2013-10-01

    Lateral epicondylitis has several different treatment methods, with no single agreed upon therapy. This article summarizes the current literature on injection therapies for lateral epicondylitis. Glucocorticoid, botulinum toxin, autologous blood, platelet-rich plasma, hyaluronic acid, polidocanol, glycosaminoglycan, and prolotherapy injections are discussed.

  20. Surface microstructure replication in injection molding

    DEFF Research Database (Denmark)

    Theilade, Uffe Arlø; Hansen, Hans Nørgaard

    2006-01-01

    In recent years, polymer components with surface microstructures have been in rising demand for applications such as lab-on-a-chip and optical components. Injection molding has proven to be a feasible and efficient way to manufacture such components. In injection molding, the mold surface topogra...

  1. 21 CFR 522.1086 - Guaifenesin injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin injection. 522.1086 Section 522.1086... Guaifenesin injection. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of guaifenesin and 50 milligrams of dextrose. (b) Sponsor. See Nos. 037990 and 059130 in § 510.600(c...

  2. Injection Molding of Plastics from Agricultural Materials

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, M.; Ruan, R.

    2001-02-22

    The objective of this research was to conduct a systematic study to relate injection molding parameters to properties of blends of starch and synthetic polymer. From this study, we wished to develop a thorough understanding of the injection molding process and gain significant insight into designing molds and aiding in developing products cheaply and efficiently.

  3. Children conceived after intracytoplasmic sperm injection (ICSI)

    DEFF Research Database (Denmark)

    Mau, C; Juul, A; Main, K M;

    2004-01-01

    The aim of the study was to evaluate current medical knowledge about children born after intracytoplasmic sperm injection (ICSI) with respect to congenital malformations, chromosome abnormalities and postnatal growth.......The aim of the study was to evaluate current medical knowledge about children born after intracytoplasmic sperm injection (ICSI) with respect to congenital malformations, chromosome abnormalities and postnatal growth....

  4. Rings with finite Gorenstein injective dimension

    DEFF Research Database (Denmark)

    Holm, Henrik Granau

    2004-01-01

    In this paper we prove that for any associative ring R, and for any left R-module M with nite projective dimension, the Gorenstein injective dimension GidRM equals the usual injective dimension idRM. In particular, if GidRR is nite, then also idRR is nite, and thus R is Gorenstein (provided that R...

  5. Anxiety and pain during dental injections

    NARCIS (Netherlands)

    van Wijk, A.J.; Hoogstraten, J.

    2009-01-01

    Objectives: The aim of this study was to study the relationship between anxiety and pain felt during a dental injection in a sample of ‘normal’ patients about to undergo ‘invasive’ dental treatment. Methods: Duration and intensity of pain during a dental injection were measured within a sample of

  6. Anxiety and pain during dental injections

    NARCIS (Netherlands)

    A.J. van Wijk; J. Hoogstraten

    2009-01-01

    Objectives: The aim of this study was to study the relationship between anxiety and pain felt during a dental injection in a sample of ‘normal’ patients about to undergo ‘invasive’ dental treatment. Methods: Duration and intensity of pain during a dental injection were measured within a sample of 24

  7. Injection Molding of High Aspect Ratio Nanostructures

    DEFF Research Database (Denmark)

    Matschuk, Maria; Larsen, Niels Bent

    We present a process for injection molding of 40 nm wide and >100 nm high pillars (pitch: 200 nm). We explored the effects of mold coatings and injection molding conditions on the replication quality of nanostructures in cyclic olefin copolymer. We found that optimization of molding parameters...

  8. Injecting Inquiry into Photosynthesis Investigations

    Science.gov (United States)

    Salter, Irene; Smith, Rebecca; Nielsen, Katherine

    2008-01-01

    This is the story of how a typical middle school lab was transformed into an open-ended inquiry experience through a few small, but very powerful, changes. By allowing students to follow their own questions, the classroom filled with enthusiasm and students learned much more about photosynthesis, respiration, and the scientific processes. The…

  9. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind;

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage...

  10. Two Cases of Accidental Injection of Epinephrine into a Digit Treated with Subcutaneous Phentolamine Injections

    Directory of Open Access Journals (Sweden)

    Ryan P. Bodkin

    2013-01-01

    Full Text Available Accidental injection into the digit from an epinephrine autoinjection device can cause discoloration, pain, and paresthesias. Although loss of digit is rare, treatment in the emergency department is commonly aimed at vasodilation of the affected tissue. We report two cases of accidental injection of epinephrine into the digits that were successfully treated with subcutaneous phentolamine injection with no adverse events.

  11. Two cases of accidental injection of epinephrine into a digit treated with subcutaneous phentolamine injections.

    Science.gov (United States)

    Bodkin, Ryan P; Acquisto, Nicole M; Gunyan, Holly; Wiegand, Timothy J

    2013-01-01

    Accidental injection into the digit from an epinephrine autoinjection device can cause discoloration, pain, and paresthesias. Although loss of digit is rare, treatment in the emergency department is commonly aimed at vasodilation of the affected tissue. We report two cases of accidental injection of epinephrine into the digits that were successfully treated with subcutaneous phentolamine injection with no adverse events.

  12. Surface micro topography replication in injection moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf

    , the topography itself, and other factors were also investigated. The experimental work is based on a multi-purpose experimental injection mould with a collection of test surface inserts manufactured by EDM (electrical discharge machining). Experimental production took place with an injection moulding machine......Thermoplastic injection moulding is a widely used industrial process that involves surface generation by replication. The surface topography of injection moulded plastic parts can be important for aesthetical or technical reasons. With the emergence of microengineering and nanotechnology additional...... in a clean room environment. The mould and the injection moulding machine were fitted with transducers for subsequent process analysis. A total of 13 different plastic material grades were applied. Topographical characterisation was performed with an optical laser focus detection instrument. Replication...

  13. Injection moulding for macro and micro products

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    The purpose of the literature survey is to investigate the injection moulding technology in the macro and micro areas from the basic to the state-of-the-art recent technology. Injection moulding is a versatile production process for the manufacturing of plastic parts and the process is extensively...... used for macro products but with the ages it is going deep into the micro areas having machine and process improvements. Extensive research work on injection moulding is going on all over the world. New ideas are flowing into the machines, materials and processes. The technology has made significant...... advancement in the area of micro injection moulding, multi-component and two component injection mounding. In near future it is likely to be the way of manufacturing moulded interconnects devices (MID) for a low cost integration of electrical and mechanical functionalities on a single device. This paper...

  14. Mechanical Weakening during Fluid Injection in Critically Stressed Sandstones with Acoustic Monitoring

    Science.gov (United States)

    David, C.; Dautriat, J. D.; Sarout, J.; Macault, R.; Bertauld, D.

    2014-12-01

    Water weakening is a well-known phenomenon which can lead to subsidence during the production of hydrocarbon reservoirs. The example of the Ekofisk oil field in the North Sea has been well documented for years. In order to assess water weakening effects in reservoir rocks, previous studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks saturated either with water or with inert fluids. However, little attention has been paid so far on the mechanical behaviour during the fluid injection stage, like in enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behaviour of Sherwood sandstone, a weakly-consolidated sandstone sampled at Ladram Bay in UK. In order to highlight possible weakening effects, water and inert oil have been injected into critically-loaded samples to assess their effect on strength and elastic properties and to derive the acoustic signature of the saturation front for each fluid. The specimens were instrumented with 16 ultrasonic P-wave transducers for both passive and active acoustic monitoring during fluid injection and loading. After conducting standard triaxial tests on three samples saturated with air, water and oil respectively, mechanical creep tests were conducted on dry samples loaded at 80% of the compressive strength of the dry rock. While these conditions are kept constant, a fluid is injected at the bottom end of the sample with a low back pressure (0.5 MPa) to minimize effective stress variations during injection. Both water and oil were used as the injected pore fluid in two experiments. As soon as the fluids start to flow into the samples, creep is taking place with a much higher strain rate for water injection compared to oil injection. A transition from secondary creep to tertiary creep is observed in the water injection test whereas in the oil injection test no significant creep acceleration is observed after one pore volume of oil was

  15. Air Flow and Gassing Potential in Micro-injection Moulding

    DEFF Research Database (Denmark)

    Griffithsa, C.A.; Dimova, S.S.; Scholz, S.

    2011-01-01

    Process monitoring of micro injection moulding (μ-IM) is of crucial importance in understanding the effects of different parameter settings on the process, especially on its performance and consistency in regards to parts’ quality. Quality factors related to mould cavity air evacuation can provide...... valuable information about the process dynamics and also about the filling of a cavity by a polymer melt. In this paper, a novel experimental set-up is proposed to monitor maximum air flow and air flow work as an integral of the air flow over time by employing a MEMS gas sensor mounted inside the mould....... The influence of four μIM parameters, melt temperature, mould temperature, injection speed, and resistance to air evacuation, on two air flow-related output parameters is investigated by carrying out a design of experiment study. The results provide empirical evidence about the effects of process parameters...

  16. Injection Induced Mixing in Flows Separating From Smooth Surfaces

    Science.gov (United States)

    Adamczyk, John J. (Technical Monitor); Wundrow, David W.

    2004-01-01

    An analytic model for predicting the effect of unsteady local surface injection on the flow separating from a streamlined body at angle of attack is proposed. The model uses the premise that separation control results from enhanced mixing along the shear layer that develops between the main stream and the fluid in the underlying recirculation zone. High-Reynolds-number asymptotic methods are used to connect the unsteady surface injection to an instability wave propagating on the separating shear layer and then to the large-scale coherent structures that produce the increased mixing. The results is a tool that can guide the choice of fluid-actuator parameters to maximize flow-control effectiveness and may also facilitate computer-based numerical experiments.

  17. Deposition of fuel pellets injected into tokamak plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Baylor, L.R.; Jernigan, T.C. [Oak Ridge National Lab., TN (United States); Hsieh, C. [General Atomics, San Diego, CA (United States)

    1998-06-01

    Pellet injection has been used on tokamak devices in a number of experiments to provide plasma fueling and density profile control. The mass deposition of these fuel pellets defined as the change in density profile caused by the pellet, has been found to show an outward displacement of the ablated material from that expected by mapping the theoretical ablation rate onto the flux surfaces. This suggests that fast transport of the pellet ablatant occurs during the flow along field lines that may be driven by {del}B drift effects. A comparison of the deposition of pellets from different machines shows similar behavior. Initial results from alternative injection locations designed to take advantage of the outward ablatant drift is presented.

  18. High Speed Fault Injection Tool Implemented With Verilog HDL on FPGA for Testing Fault Tolerance Designs

    Directory of Open Access Journals (Sweden)

    G. Gopinath Reddy

    2013-11-01

    Full Text Available This paper presents an FPGA-based fault injection tool, called FITO that supports several synthesizable fault models for dependability analysis of digital systems modeled by Verilog HDL. Using the FITO, experiments can be performed in real-time with good controllability and observability. As a case study, an Open RISC 1200 microprocessor was evaluated using an FPGA circuit. About 4000 permanent, transient, and SEUfaults were injected into this microprocessor. The results show that the FITO tool is more than 79 times faster than a pure simulation-based fault injection with only 2.5% FPGA area overhead.

  19. Theoretical prediction of regression rates in swirl-injection hybrid rocket engines

    Science.gov (United States)

    Ozawa, K.; Shimada, T.

    2016-07-01

    The authors theoretically and analytically predict what times regression rates of swirl injection hybrid rocket engines increase higher than the axial injection ones by estimating heat flux from boundary layer combustion to the fuel port. The schematic of engines is assumed as ones whose oxidizer is injected from the opposite side of the nozzle such as ones of Yuasa et al. propose. To simplify the estimation, we assume some hypotheses such as three-dimensional (3D) axisymmetric flows have been assumed. The results of this prediction method are largely consistent with Yuasa's experiments data in the range of high swirl numbers.

  20. Induction Heating System Applied to Injection Moulding of Micro and Nano Structures

    DEFF Research Database (Denmark)

    Menotti, Stefano

    embedded induction heating system with other heating systems suitable for injection moulding already available on the market. The two selected systems were a variothermal system based on the convective/conductive heating principle and one based on infrared light. During the project simulation software...... and for understanding the influence of the main process parameters on the quality of the parts. The experiments were conducted on a manual injection machine for the first campaign and in a second phase on two different completely automatic injection moulding machines. Metrology was performed to characterize the moulded...