WorldWideScience

Sample records for ct-guided fine-needle puncture

  1. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  2. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-01-01

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  3. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com [Matsuyama Shimin Hospital, Department of Radiology (Japan); Watanabe, Ryouhei; Koyano, Yasuhiro [Matsuyama Shimin Hospital, Department of Surgery (Japan); Sugata, Shigenori; Takeda, Yukie [Ehime Prefectural Imabari Hospital, Department of Radiology (Japan); Nakamura, Seiji; Akamune, Akihisa [Matsuyama Shimin Hospital, Department of Radiology (Japan); Tsuda, Takaharu; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology (Japan)

    2017-04-15

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  4. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  5. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  6. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  7. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  8. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  9. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  10. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  11. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  12. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  13. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  14. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  15. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  16. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  17. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  18. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  19. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  20. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  1. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  2. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  3. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  4. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  5. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  6. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  7. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  8. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  9. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  10. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  11. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  12. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well

  13. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  14. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  15. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  16. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  17. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  18. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  19. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  20. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  1. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  2. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  3. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  4. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  5. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  6. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  7. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  8. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  9. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  10. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  11. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  12. A new device of CT-targeted percutaneous punctures

    International Nuclear Information System (INIS)

    Ozdoba, C.

    1990-01-01

    This paper reports on a device for CT-targeted percutaneous punctures. After extensive phantom studies, punctures of vertebral disk space (diskography/nucleotomy) and orbit retrobulbar anesthesia/biopsy were performed in 15 patients. The new device is easy to mount on the CT scanner and does not require additional devices affixed to the patient. Its design and construction permit exact calculation of needle angle and depth, even when the gantry is tilted. Percutaneous biopsies can be performed in approximately 40 minutes. The device is accurate within ±0.5 mm, thereby allowing puncture of even small lesions deep in the orbital cone. Retrobulbar anesthesia can be performed safely in patients with a long myopic bulbus; in nucleotomy, instant control of the instrument's position within the disk space is possible

  13. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  14. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  15. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  16. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  17. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  19. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  20. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  1. CT-guided cervical interlaminar epidural steroid injection for cervical radiculopathy

    International Nuclear Information System (INIS)

    Chen Wei; Wu Chungen; Wu Chaoxian; Cheng Yongde

    2009-01-01

    Objective: To evaluate the safety and effectiveness of CT-guided cervical interlaminar epidural steroid injection for the treatment of cervical radiculopathy. Methods: CT-guided cervical interlaminar epidural steroid injection was performed in 32 patients with cervical radioculopathy, encountered during the period of Dec. 2006 to June 2008, as the patients failed to respond to the conservative treatment in 2 weeks. The clinical data and the imaging findings were retrospectively analyzed. Before and after the procedure, visual analogue scale (VAS) and Odom criteria were used to evaluate the pain of the patient. Results: Three months after the injection, improvement judged by Odom criteria was seen in 28 patients (87.5%), and the mean pain relief value of VAS was 5.88 ± 1.10. No significant difference in effective rate and in VAS score (P>0.05) was found between protrusion group and degenerative group, between the group with the course over 6 months and the group with the course below 6 months, also between the group receiving one injection and the group receiving the second injection. Conclusion: CT-guided fine needle (23 gauge) puncture epidural steroid (Decadron) 'target spot' injection is an ideal alternative for the treatment of cervical radiculopathy, especially for the patients who fails to respond to the conservative treatment. (authors)

  2. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  3. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  4. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  5. Clinical experience of quantex coordinate software for CT guided stereotactic surgery

    International Nuclear Information System (INIS)

    Yabashi, Toshitake; Ichikawa, Hideo; Yasuda, Eisuke; Tsuruta, Hatsuo; Ishikawa, Yoshihisa; Kimura, Tokuji; Kanamori, Isao

    1991-01-01

    Recently, Quantex Coordinate Software was newly developed for CT-guided stereotactic surgery. We have the opportunity of using this software in 6 cases with intracerebral hematoma for evacuation and 2 cases with brain tumor for needle biopsy by using CT-guided stereotactic surgery. The followings are the features with a little clinical experience. One of the biggest features is that this software can simulate the best expected route of the puncture needle from burr hole to target point before inserting. Also compared with CT 9000 series Software, it has many new functions for more advanced hardware as well as advance standard software. Two cases of intracerebral hematoma for evacuation and 1 case of a brain tumor for a biopsy were carried out using this software mainly as a simulation. In all cases, this software proved to be very useful. (author)

  6. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    Science.gov (United States)

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  7. CT-guided percutaneous neurolysis methods. State of the art and first results

    International Nuclear Information System (INIS)

    Schneider, B.; Richter, G.M.; Roeren, T.; Kauffmann, G.W.

    1996-01-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [de

  8. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  9. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  10. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  11. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  12. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  13. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  14. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  15. CT-guided percutaneous vertebroplasty for the treatment of metastases in the cervical spine

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Zhentang; Zuo Changjing; Shao Chenwei; Chen Wei; Lv Taozhen; Dong Aisheng

    2009-01-01

    Objective: To assess the clinical efficacy and complications of CT-guided percutaneous vertebroplasty in the treatment of metastases of the cervical spine, and to discuss the proper needle path for different cervical vertebra. Methods: CT-guided percutaneous vertebroplasty was performed in 17 patients with cervical vertebral metastatic neoplasm, and the results of the treatment were retrospectively analyzed. Close observation was carded out after the procedure and a follow-up of 3-17 months was conducted. A comparison of the visual analogue pain scale (VAS) and Frankel's classification between pre-and post- operation was made. The occurrence of complications was recorded. The optimal needle path was summarized. Results: (1) The successful puncture was achieved in all 17 cases. The needle pathway included: the front of carotid sheath (n=4), between carotid sheath and vertebral artery (n=11) and behind the vertebral artery and carotid sheath (n=2). (2) Before the procedure the VAS was 7.24 ± 1.01, and at the time of one hour, one week and three months after the procedure it was decreased to 3.24 ± 1.09, 2.40 ± 0.80 and 1.82 ± 0.53 respectively. Wilcoxon signed-rank test showed that the difference in VAS between pre-and post- operation was statistically significant (T=76.5, P 2 =4.52, P=0.033 and P<0.05 when Kruskal-Wallis test was adopted. (3) CT scanning immediately after the procedure showed that slight leakage of cement to the adjacent disc, epidural fat, parosteal tissue or to the needle path occurred in 35.3% with no serious complications. In a follow-up period of 3-17 months, the metastatic lesions remained stable in 14 cases (82.4%). Conclusion: (1) The optimal needle path for upper cervical vertebrae is posterolateral transpedicular approach while for the lower cervical vertebrae it is more reasonable to puncture via the front carotid sheath or between carotid sheath and vertebral artery. Nevertheless, the puncture pathway should be devised individually

  16. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  17. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  18. Tracheobronchial puncture-site nodular reaction (TPNR following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA: Systematic review of case reports

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  19. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  20. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  1. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  2. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  3. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  4. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  5. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  6. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  7. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  8. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  9. CT-guided percutaneous radiofrequency ablation of hepatic malignancies located in unusual regions under general anesthesia

    International Nuclear Information System (INIS)

    Pan Jie; Chen Shaohui; Lu Xin; Mao Yilei; Sang Xinting; Chen Fang; Li Yumei; Huang Yuguang; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility of CT-guided percutaneous radiofrequency ablation (RFA) of liver malignancies located in unusual regions under general anesthesia, and to assess its clinical value. Methods: Eighteen patients with a total of 26 malignant hepatic lesions were enrolled in this study. The lesions were located at diaphragmatic surface, hepatic hilum, hepatic subcapsular site,side of inferior vena cava, side of gallbladder or near by colon. Transcatheter arterial chemoembolization was performed in all patients, which was followed by CT-guided percutaneous RFA under general anesthesia. The time used for puncturing and the time used for putting the needles to the scheduled sites were recorded. A follow-up for 115 months was conducted. The complications and the therapeutic results were observed. Results: For all patients,the procedure of puncture and needle placement was completed in 1-3 minutes. A total of 35 RFA procedures were conducted for 26 lesions. No severe complications occurred. Complete necrosis was observed in 20 tumors and partial necrosis in 6 tumors. Conclusion: The result of this study indicates that CT-guided percutaneous RFA under general anesthesia is a feasible technique for the treatment of liver malignancies located at unusual regions. This technique is very helpful for reducing the manipulating difficulty and lowing the complication risk of RFA procedures. (authors)

  10. Study of DSA-guided percutaneous puncture location of foramen oval

    International Nuclear Information System (INIS)

    Zhao Xiaojun; He Jiawei; Bai Guanghui; Shi Jianjing; Xu Chongyong; Zhan Gonghao

    2008-01-01

    Objective: To study the technique of digital substraction angiography (DSA)-guided percutaneous puncture location of foramen oval. Methods: 39 cases of trigeminal neuralgia were included in the study from Feb. 2004 to Oct. 2006. The patients were punctured by the amending anterior position. The f0ramen oval was displayed by moving the tube tilted 20-28 degree to the caudal and 16-23 degree to the healthy side. The direction and depth of the needles was determined on the lateral view. Then, radio-frequency thermocoagulation therapy was performed. Results: The needles were located in oval foramen in all the patients. Pain disappeared in 36 cases, alleviated in other cases, and no serious complication occurred during therapy. Conclusions: Oval foramen locations by DSA can improve the successful rate of operation. The foramen oval can be clearly displayed by DSA-guided in amending position, with comfortable position for patients. (authors)

  11. Learning curve of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  13. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  14. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  15. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  16. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  17. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    Science.gov (United States)

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  18. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  19. Metastatic Chordoma: A Diagnostic Challenge on Fine Needle Aspiration

    Directory of Open Access Journals (Sweden)

    Ghassan Tranesh

    2016-01-01

    Full Text Available Chordomas are primary low grade malignant tumors of bone that usually arise within both ends of axial skeleton. The Notochord is a midline, ectoderm-derived structure that defines the phylum of chordates. Chordomas may pose difficult diagnostic challenges when encountered in secondary locations, such as lungs or other parenchymatous organs. We report the cytologic findings of a metastatic chordoma sampled through CT-scan guided fine needle aspiration (FNA of lower lobe lung nodule in a 54-year-old man diagnosed with recurrent chordoma involving the lumber spine and paraspinal region.

  20. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    Science.gov (United States)

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  1. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    Science.gov (United States)

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  2. The factor analysis of the incidence of pneumothorax after CT-guided transthoracic needle aspiration biopsy

    International Nuclear Information System (INIS)

    Zhong Tao; Yu Hongguang; Wang Yong; Yang Sifu; Wang Xiaoxuan

    2007-01-01

    Objective: To analyze the impact of multiple factors on the incidence of pneumothorax associated with CT-guided transthoracic needle aspiration biopsy. Methods: The sign of pneumothorax after 162 cases (lesion diameter from 1 cm to 6 cm) CT-guided transthoracic needle aspiration biopsy was observed and its relationship with multivariate factors were analyzed by multivariate logistic regression model. Results: Thirty-two cases presented pneumothorax accounting for 19. 8%. Single variate analysis showed that the sign of pneumothorax related to intercurrent COPD, distance from lesion and chest wall, needle dwelling time and lesion diameter. 67 patients of intercurrent COPD with postoperative pneumothorax occurred in 22 cases (32.8%); With respect to those having lesions close to the chest wall (48 cases), and the cases with the distance between the chest wall and lesions less than 2 cm (55 cases) and greater than 2 cm (59 cases), the postoperative pneumothorax occurred in 0, 14 (25.5%), 18 (30.5%) cases respectively; For those patients with needle in the chest residence time of less than 10 minutes (82 cases), 10-20 minutes (51 cases), more than 20 minutes (28 cases) after the occurrence of pneumothorax were 8 (9.6%), 10(19.6%), 14 (50%) cases respectively; In contrast, those with lesion diameter less than 2 cm (65 cases), 2-4 cm(52 cases), more than 4cm(45 cases) were 19 (29.2%), 8 (15.4%) and 5 (11.1% ) respectively. The multivariate logistic regression analysis showed that the prior three factor's were risk factors of pneumothorax (OR=4.652, 4.030, 2.855 respectively). Conclusions: To avoid the pneumothorax, caution must be taken with respect to CT-guided transthoracic needle aspiration biopsy, patients with intercurrent COPD, long distance between lesion and chest wall, and smaller lesion diameter. For operation the needle dwell time within thorax should be minimized. (authors)

  3. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  4. The value of ultrasound with ultrasound-guided fine-needle aspiration biopsy compared to computed tomography in the detection of regional metastases in the clinically negative neck

    International Nuclear Information System (INIS)

    Takes, Robert P.; Righi, Paul; Meeuwis, Cees A.; Manni, Johannes J.; Knegt, Paul; Marres, Henri A.M.; Spoelstra, Hubert A.A.; Boer, Maarten F. de; Mey, Andel G.L. van der; Bruaset, I.; Ball, Valerie; Weisberger, Edward; Radpour, Shokri; Kruyt, Rene H.; Joosten, Frank B.M.; Lameris, Johan S.; Oostayen, Jacques A. van; Kopecky, Kenyon; Caldemeyer, Karen; Henzen-Logmans, Sonja C.; Wiersma-van Tilburg, J.M.; Bosman, Fred T.; Krieken, J. Han J.M. van; Hermans, Jo; Baatenburg de Jong, Robert J.

    1998-01-01

    Purpose: Head and neck oncologists have not reached consensus regarding the role of contemporary imaging techniques in the evaluation of the clinically negative neck in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to compare the accuracy of ultrasound with guided fine-needle aspiration biopsy (UGFNAB) and computed tomography (CT) in detecting lymph node metastasis in the clinically negative neck. Methods and Materials: Sixty-four neck sides of patients with HNSCC were examined preoperatively by ultrasound/UGFNAB and CT at one of five participating tertiary care medical centers. The findings were correlated with the results of histopathologic examination of the neck specimen. Results: Ultrasound with guided fine-needle aspiration biopsy was characterized by a sensitivity of 48%, specificity of 100%, and overall accuracy of 79%. Three cases had nondiagnostic aspirations using UGFNAB and were excluded. CT demonstrated a sensitivity of 54%, specificity of 92%, and overall accuracy of 77%. UGFNAB detected two additional metastases not visualized on CT, whereas CT detected no metastases not seen on UGFNAB. The results of UGFNAB were similar between the participating centers. Conclusions: Approximately one half of the clinically occult nodal metastases in our patient group were identified by both CT and UGFNAB. Overall, UGFNAB and CT demonstrated comparable accuracy. The sensitivity of CT was slightly better than UGFNAB, but the latter remained characterized by a superior specificity. The results of CT and UGFNAB did not appear to be supplementary. The choice of imaging modality for staging of the clinically negative neck depends on tumor site, T-stage, and experience and preference of the head and neck oncologist. If CT is required for staging of the primary tumor, additional staging of the neck by UGFNAB does not provide significant additional value

  5. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  6. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Nagel, Markus; Elfring, Robert; Schmitz-Rode, Thomas; Gronloh, Nina; Guenther, Rolf W.; Mahnken, Andreas H.

    2009-01-01

    An electromagnetic-based tracking and navigation system was evaluated for interventional radiology. The electromagnetic tracking system (CAPPA IRAD EMT, CASinnovations, Erlangen, Germany) was used for real-time monitoring of punctures of the lumbar facet joints and intervertebral disks in a spine phantom, three pig cadavers and three anaesthesized pigs. Therefore, pre-interventional computed tomography (CT) datasets were transferred to the navigation system and puncture trajectories were planned. A coaxial needle was advanced along the trajectories while the position of the needle tip was monitored in real time. After puncture tracts were marked with pieces of wire another CT examination was performed and distances between wires and anatomical targets were measured. Performing punctures of the facet joints mean needle positioning errors were 0.4 ± 0.8 mm in the spine phantom, 2.8 ± 2.1 mm ex vivo and 3.0 ± 2.0 mm in vivo with mean length of the puncture tract of 54.0 ± 10.4 mm (phantom), 51.6 ± 12.6 mm (ex vivo) and 50.9 ± 17.6 mm (in vivo). At first attempt, intervertebral discs were successfully punctured in 15/15 in the phantom study, in 12/15 in the ex-vivo study and 14/15 in the in-vivo study, respectively. Immobilization of the patient and optimal positioning of the field generator are essential to achieve a high accuracy of needle placement in a clinical CT setting. (orig.)

  7. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  8. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  9. Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach

    International Nuclear Information System (INIS)

    Kim, Young Kon; Kim, Chong Soo; Lee, Jeong Min; Chung, Gyung Ho; Chon, Su Bin

    2006-01-01

    Purpose: The purpose of this study was to determine the efficacy and safety of radiofrequency (RF) ablation for the treatment of hepatocellular carcinoma (HCC) in the hepatic dome with CT-guided extrathoracic transhepatic approach. Materials and methods: Fifteen patients with 15 HCCs (size range: 0.8-4 cm, mean size: 1.8 cm) in the hepatic dome were treated by RF ablation using cooled-tip electrodes and with CT-guided extrathoracic transhepatic approach. Therapeutic response of the tumor to RF ablation and procedure-related complications including hepatic injury, hemoperitoneum, and thermal injury of diaphragm were evaluated. Results: The average number of needle punctures to ensure the correct needle position in the targeted tumor was 3.7 (range: 1-6 punctures). The average ablation time was 14.7 min (range: 8-25 min). Complete necrosis without marginal recurrence after at least 13-month follow-up was attained in 13 tumors (86.7%). There were no major complications related to the procedures. Six patients had shoulder pain that lasted three days to two weeks after the procedures and their symptoms were resolved with conservative treatment. Conclusions: RF ablation using CT-guided extrathoracic transhepatic approach is an effective and safe technique for the treatment of HCC in the hepatic dome

  10. Guided fine needle aspiration cytology of retroperitoneal masses - Our experience

    Directory of Open Access Journals (Sweden)

    Mimi Gangopadhyay

    2011-01-01

    Full Text Available Background : Early pathological classification of retroperitoneal masses is important for pin-point diagnosis and timely management. Aims : This study was done to evaluate the usefulness and drawbacks of guided fine needle aspiration cytology (FNAC of retroperitoneal masses covering a period of two years with an intention to distinguish between neoplastic and non-neoplastic lesions and to correlate with histologic findings. Materials and Methods : FNAC was done under radiological guidance in all cases using long needle fitted with disposable syringe. Appropriate staining was done and cytology was correlated with histology which was taken as the gold standard for comparison. Results : Fifty-one patients who presented with retroperitoneal masses were studied. Forty-four lesions were malignant cytologically and 7 were inflammatory (tuberculous. According to radiological and cytologic findings, we classified our cases into four groups: renal tumors, retroperitoneal lymphadenopathy, germ cell tumors, soft tissue tumors. Except for cases of non-Hodgkin lymphoma (NHL and metastatic lesions, we had sensitivity and specificity of 100%. In NHL the sensitivity and specificity were both 50%. In cases of metastatic adenocarcinoma, the sensitivity and specificity were 84.6% and 81.8%, respectively. Conclusions : Ignoring the pitfalls, guided FNAC is still an inexpensive and reliable method of early diagnosis of retroperitoneal lesions.

  11. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  12. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  13. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  14. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  15. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  16. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  17. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de [University Hospital of Cologne, Department of Diagnostic and Interventional Radiology (Germany); Pech, Maciej [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany); Lux, Anke [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics (Germany); Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany)

    2017-06-15

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

  18. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  19. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  20. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  1. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  2. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    Science.gov (United States)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  3. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  4. Diagnosis of verminous pneumonia via sonography-guided fine-needle pulmonary parenchymal aspiration in a cat

    Directory of Open Access Journals (Sweden)

    Jennifer Gambino

    2016-04-01

    Full Text Available Case summary A 9-year-old, male neutered, indoor–outdoor domestic shorthair cat from the northern Alabama countryside presented for a 3 week history of coughing, lethargy and an episode of self-resolving dyspnea that occurred 1 week prior to presentation. Three-view thoracic radiographs revealed a moderate-to-severe, diffuse, mixed bronchial to structured interstitial (miliary-to-nodular pulmonary pattern in all lung lobes with peribronchial cuffing and multifocal areas of mild patchy alveolar opacity. Ultrasound-guided evaluation and fine-needle aspiration of the caudodorsal lung parenchyma was performed with sedation. Cytology revealed many widely scattered Aelurostrongylus abstrusus larvae and ova. Upon the confirmed diagnosis of A abstrusus verminous pneumonia, treatment with fenbendazole and selamectin resulted in complete resolution of clinical signs within 6 weeks of the initial diagnosis. Relevance and novel information We report herein the first documented case in the Americas of A abstrusus verminous pneumonia diagnosed via cytologic evaluation of an in vivo, percutaneous ultrasound-guided fine-needle aspirate of affected lung. Additionally, to our knowledge, we offer the first account of the sonographic (pulmonary features of the disease.

  5. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  6. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  7. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  8. CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes for the treatment of intractable carcinomatous abdominal pain

    International Nuclear Information System (INIS)

    Xi Qian; Wang Peijun; Shang Mingyi; Ma Jun; Lu Ying; Huang Zongliang; Tang Junjun; Gao Xiaolong

    2010-01-01

    Objective: To evaluate CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes in treating intractable carcinomatous abdominal pain. Methods: A total of 104 patients with late stage cancers were enrolled in this study. All patients suffered from serious carcinomatous pain at upper abdomen and their retroperitoneal lymph nodes were extensively enlarged and fused, together with the involved celiac plexus, into a hard crumb. As the patients failed to respond to narcotic analgesics CT-guided ethanol nerve block therapy of celiac plexus was carried out by pushing the puncture needle through the fused lymphatic mass to celiac plexus site. The analgesic effects and complications were observed and the therapeutic results were evaluated. Results: The analgesic effective rate of ethanol nerve block therapy immediately after the procedure was 100%, and at 2 weeks, 1, 2, 3 and 4 months after the treatment it was 100%, 100%, 98.0%, 96.9% and 92.6%, respectively. No serious complications occurred during perioperative period. The living quality was markedly improved in all patients. Conclusion: For the treatment of intractable carcinomatous abdominal pain in patients with their celiac plexus being embedded in mass-like metastatic retroperitoneal lymph nodes CT-guided percutaneous ethanol nerve block therapy by pushing the puncture needle through the fused lymphatic mass to celiac plexus site is of great clinical value in relieving carcinomatous abdominal pain. (authors)

  9. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  10. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  11. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    Science.gov (United States)

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  12. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  13. The optical "Veress-needle"--initial puncture with a minioptic.

    Science.gov (United States)

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  15. Assessment of pain score and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Liao LJ

    2017-12-01

    Full Text Available Li-Jen Liao,1 Wu-Chia Lo,1 Wan-Lun Hsu,2 Po-Wen Cheng,1 Cheng-Ping Wang3 1Department of Otolaryngology, Far Eastern Memorial Hospital, 2Genomics Research Center, Academia Sinica, 3Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China Objective: The aim of this study was to evaluate pain scores and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy (US-FNAB of thyroid nodules without and with local anesthesia (LA. Materials and methods: The US-FNAB procedure was performed on 183 patients with and without LA. One puncture was made for solid nodules, and if patients could tolerate it, a two-puncture technique was used for nodules with a cystic change. Four-point verbal rating scores were assessed by a nursing assistant after completion of US-FNAB. To be an adequate specimen, at least six groups of follicular cells are required, and each group should contain at least 10 cells.Results: Immediately after US-FNAB, 92% of patients with LA and 80% without LA reported no or mild pain (p=0.01. Most patients tolerated the procedure well, with no pain (82.5% reported 5 minutes after the procedure. In univariate logistic regression, irregular boundary (odds ratio [OR]: 2.52, 95% confidence interval [CI]: 1.04–6.06, p=0.04, calcification (OR: 2.86, 95% CI: 1.06–7.76, p=0.04, and LA (OR: 0.35, 95% CI: 0.15–0.86, p=0.02 were significantly associated with immediate moderate or severe pain. Specimen adequacy was significantly associated with age (OR: 0.95, 95% CI: 0.92–0.97, p<0.01, heterogeneous echo-texture (OR: 1.76, 95% CI: 1.23–5.17, p=0.01, predominate solid architecture (OR: 2.78, 95% CI: 1.42–5.41, p<0.01, and the use of LA (OR: 3.34, 95% CI: 1.70–6.56, p<0.01. In multivariate logistic regression, patients receiving LA had lower risk of moderate or severe pain (OR: 0.25, 95% CI: 0.09–0.67, p=0.01 and higher chances of specimen adequacy (OR: 4.84, 95% CI: 2.17–10.7, p<0

  16. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  17. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    Science.gov (United States)

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  18. Does obesity preclude lumbar puncture with a standard spinal needle? The use of computed tomography to measure the skin to lumbar subarachnoid space distance in the general hospital population.

    LENUS (Irish Health Repository)

    Halpenny, Darragh

    2013-06-05

    OBJECTIVES: Failed lumbar puncture (LP) is a common indication for referral for radiologically guided LP. This study aims to evaluate what percentage of the hospital population would fail an LP using a standard 9-cm needle because of obesity and a skin to subarachnoid space distance greater than 9 cm. METHODS: Images of 402 consecutive patients undergoing computed tomography of the abdomen and pelvis were reviewed. Skin to subarachnoid space distance was calculated using sagittal images. A survey was conducted among junior hospital doctors to assess their experience of performing lumbar puncture in obese patients. RESULTS: Four hundred patients were included. Fifty-five patients (13.8 %) had a skin to subarachnoid space distance greater than 9 cm. Intra-abdominal fat, subcutaneous fat and abdominal girth correlated with distance between the skin and subarachnoid space. Among junior doctors, 68.3 % (n = 41) reported LP failure on an obese patient; 78.4 % (n = 47) were unaware of the existence of a longer needle and 13.3 % (n = 8) had experience using a longer needle. CONCLUSIONS: A significant proportion of the hospital population will fail LP with a standard length spinal needle. Selecting a longer needle may be sufficient to successfully complete LP in obese patients. KEY POINTS : • Lumbar puncture failure commonly leads to referral for an image-guided procedure • Standard lumbar puncture may fail in 13.8 % of patients due to obesity • 78.4 % of trainee doctors are unaware of the existence of longer spinal-needles • Using longer spinal needles may allow successful LP in obese patients.

  19. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  20. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong [Huazhong University of Science and Technology, Cancer Center, Union Hospital, Tongji Medical College, Wuhan (China)

    2017-08-15

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. (orig.)

  1. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  2. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  3. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  4. Fine needle aspiration biopsy of pancreas. Cytological assessment

    International Nuclear Information System (INIS)

    Coufal, L.; Heger, L.

    1987-01-01

    The benefits are presented of cytological examination of bioptical material from the pancreas using computerized tomography (CT) or ultrasound. The case is presented of one patient who had repeatedly undergone endoscopy with no results. Only cytological examination of material sampled using fine needle aspiration under CT control helped to immediately diagnose the process. The cytological finding correlated with the histological examination of material later taken during surgery. The problems are discussed of the differential diagnosis of tumors of the pancreas. (author). 5 figs., 9 refs

  5. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  6. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  7. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    International Nuclear Information System (INIS)

    Issy, A.C.; Castania, V.; Castania, M.; Salmon, C.E.G.; Nogueira-Barbosa, M.H.; Bel, E. Del; Defino, H.L.A.

    2013-01-01

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration

  8. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    Energy Technology Data Exchange (ETDEWEB)

    Issy, A.C.; Castania, V.; Castania, M. [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Salmon, C.E.G. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Nogueira-Barbosa, M.H. [Divisão de Radiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Bel, E. Del [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Defino, H.L.A. [Departamento de Biomecânica, Medicina e Reabilitação do Sistema Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-03-15

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration.

  9. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  10. Effect of needle puncture and electro-acupuncture on mucociliary clearance in anesthetized quails

    Directory of Open Access Journals (Sweden)

    Wang Tianshan

    2006-02-01

    Full Text Available Abstract Background Acupuncture therapy for obstructive respiratory diseases has been effectively used in clinical practice and the acupuncture points or acupoints of Zhongfu and Tiantu are commonly-used acupoints to treat patients with the diseases. Since the impaired mucociliary clearance is among the most important features of airway inflammation in most obstructive respiratory diseases, the effect of needle puncture and electro-acupuncture at the specific acupoints on tracheal mucociliary clearance was investigated in anesthetized quails. Methods Mucociliary transport velocity on tracheal mucosa was measured through observing the optimal pathway, and fucose and protein contents in tracheal lavages were determined with biochemical methods. In the therapeutic group, needle puncture or electro-acupuncture stimulation to the acupoints was applied without or with constant current output in 2 mA and at frequency of 100 Hz for 60 minutes. In the sham group, electro-acupuncture stimulation to Liangmen was applied. Results Our present experiments demonstrated that the electro-acupuncture stimulation to Zhongfu and Tiantu significantly increased tracheal mucociliary transport velocity and decreased the content of protein in the tracheal lavage, compared with the control group. Moreover, either needle puncture or electro-acupuncture stimulation to Zhongfu and Tiantu significantly reverted the human neutrophil elastase-induced decrease in tracheal mucociliary transport velocity and human neutrophil elastase -induced increase in the contents of fucose and protein in the tracheal lavage, compared with the control group. Conclusion These results suggest that either needle puncture or electro-acupuncture stimulation to the effective acupoints significantly improves both airway mucociliary clearance and the airway surface liquid and that the improvements maybe ascribed to both the special function of the points and the substantial stimulation of electricity.

  11. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment.

    Science.gov (United States)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Günther, Rolf W; Mahnken, Andreas H

    2010-08-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 +/- 1.1 mm (5 W), 6.0 +/- 2.0 mm (10 W) and 5.2 +/- 0.51 mm (20 W) in liver and 5.0 +/- 0.7 mm (5 W), 6.6 +/- 0.9 (10 W) and 6.0 +/- 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 +/- 4.6 mm (10 W) in liver and 6.0 +/- 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 +/- 4.4 mm in kidney and 11.1 +/- 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy.

  12. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Guenther, Rolf W.; Mahnken, Andreas H.

    2010-01-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 ± 1.1 mm (5 W), 6.0 ± 2.0 mm (10 W) and 5.2 ± 0.51 mm (20 W) in liver and 5.0 ± 0.7 mm (5 W), 6.6 ± 0.9 (10 W) and 6.0 ± 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 ± 4.6 mm (10 W) in liver and 6.0 ± 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 ± 4.4 mm in kidney and 11.1 ± 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy. (orig.)

  13. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    Science.gov (United States)

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  14. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Groezinger, Gerd; Maurer, Michael; Grosse, Ulrich; Horger, Marius; Nikolaou, Konstantin; Syha, Roland [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lauer, Ulrich M. [University of Tuebingen, Internal Medicine I, Department of Gastroenterology, Hepatology and Infectious disease, Tuebingen (Germany)

    2016-12-15

    Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. (orig.)

  15. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  16. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  17. CT guided transthoracic fine needle aspiration biopsy (TFNAB) of the chest tumours; Transtorakalna biopsja aspiracyjna cienkoiglowa (TBAC) guzow umiejscowionych w klatce piersiowej pod kontrola obrazu tomografii komputerowej

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, J; Legaszewski, T; Skrzelewski, S; Sraga, W [Katedra i Zaklad Radiologii Lekarskiej i Radiodiagnostyki, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Zajecki, W [Katedra i Klinika Chirurgii Klatki Piersiowej, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Harasim, J [Katedra i Zaklad Patomorfologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Polonska, A [Katedra i Klinika Fizjopneumonologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland

    2003-07-01

    Tumours spreading within the chest are nowadays diagnosed based on computed tomography (CT). The aim of this paper is to present a few years experience in transthoracic fine needle aspiration biopsy of lung tumours and tumour-like lesions in adjacent tissues and organs during CT examination. To make an accurate diagnosis, the authors performed 124 TFNAB in 116 patients. About 2/3 of the biopsies were performed in patients with a tumour size from 1 to 5 cm in diameter, adjacent or located peripherally to the chest wall. The valuable cellular material, which enabled us to define a type of a disease and to make a final clinical diagnosis, was obtained in nearly 80% of cases. The complications were found in 10 patients (8.6% of all patients). Pneumothorax was found in eight cases and pulmonary bleeding (bleeding into pulmonary parenchyma and bleeding from respiratory duct) in two cases. The authors emphasized the significance of TFNAB in obtaining valuable material for fine spectrum study and discussed the problem of safety related to this procedure. (author)

  18. CT and fluoroscopy guided celiac ganglion block

    International Nuclear Information System (INIS)

    Lim, Sun Kyung; Kwon, Dae Ik; Ahn, Hyup; Kim, Jong Il; Kim, Byung Young; Lee, Jong Gil

    1994-01-01

    To evaluate the effects and usefulness of fluoroscopy guided celiac ganglion block after marking of needle path with CT scan. Celiac ganglion block with 100% ethyl alcohol was performed in 50 cancer patients who were inoperable and had intractable abdominal pain. Duration and degree of pain relief after the procedure and its complication were analyzed. Early pain relief was observed in 98% and long term relief in 68% without serious complication. Fluoroscopy guided celiac ganglion block after marking of needle path with CT scan was a safe and valuable procedure in relieving intractable pain in terminal cancer patients and reduced the time in the CT room

  19. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  20. CT guided interventional therapy for hypertensive cerebral hemorrhage

    International Nuclear Information System (INIS)

    Lin Bo; Duan Bing

    2009-01-01

    Objective: To discuss the curative effect of CT-guided puncture and drainage in treating hypertensive cerebral hemorrhage. Methods: Adjusting the suitable point and direction of puncture according to the form and size of the haematoma and patient's status, the haematoma was eliminated by minimally invasive puncture and drainage guided under CT layer image in 40 cases of hypertensive cerebral hemorrhage. Results: Modality rate of treatment group was 12.5% (5/40), and is much lower than control group, which was 45% (13/30) (P<0.01). When asscess the Activities of Daily Living (ADL) after 6 months follow-up, the ADL1-ADL3 scale in treatment group was 27 cases (70%), and was much higher than that in control group, which was 29.4% (5/17), (P < 0.05). Conclusion: Minimal invasive therapy of cerebral hemorrhage has great superiority in elimination most part of the hematoma such as simple, accurate location, low cost, safe and effective, and is worthy of recommendation clinically. (authors)

  1. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  2. CT-guided percutaneous neurolysis methods. State of the art and first results; CT-gesteuerte Neurolysen. Stand der Technik und aktuelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Richter, G.M. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Roeren, T. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-09-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [Deutsch] Thorakale und lumbale Sympathikolyse sowie die Zoeliakusblockade

  3. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho [Ajou Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69{+-}2.0 and 1.11{+-}2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the

  4. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho

    1997-01-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69±2.0 and 1.11±2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the pulmonary

  5. Experience of CT Guided Procedures in the Diagnosis of 55 patients ...

    African Journals Online (AJOL)

    All fine needle aspirations were performed with 20-gauge needles while core tissue biopsies were performed with 14 –gauge needles under CT guidance. The diagnostic yield of these procedures, complications, and patient's feedback were studied. Results: Diagnosis was malignant lesions in 18(32.1%), benign in ...

  6. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    Science.gov (United States)

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  8. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  9. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  10. [Value of ultrasonically-guided liver puncture biopsy in the diagnosis of primary liver cancer. Apropos of 84 cases].

    Science.gov (United States)

    Peghini, M; Eynard, J P; Vergne, R; Seurat, P; Barabe, P; Aubry, P; Diallo, A; Gueye, P M

    1987-01-01

    Ultrasonographicaly guided fine needle aspiration of liver was performed in 84 patients having a confirmed HCC. This technics utilizes a CHIBA type fine needle, after blood coagulation tests have been checked. Out of 84 fine needle aspirations performed: 64 were positive (76,2%), 9 negative (10,7%), 11 (13,19%) were questionable (6) or nonanalysable (5). It is ascertained that the sensibility of this technics is over 75%. It should be possible to improve it by repeating such an exam in previously negative patients. The causes of failure are discussed. Tolerance of the technics is good. It is attraumatic, and of very easily performance. No accident, no mishap was noted.

  11. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  12. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  13. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  14. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  15. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  16. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  17. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  18. Ultrasound-guided fine needle aspiration of thyroid nodules: A consensus statement by the Korean Society of Thyroid Radiology

    International Nuclear Information System (INIS)

    Lee, Young Hen; Baek, Jung Hwan; Jung, So Lyoung; Kwak, Jin Young; Kim, Ji Hoon; Shin, Jung Hee

    2015-01-01

    Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

  19. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  20. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  1. Linear-motion tattoo machine and prefabricated needle sets for the delivery of plant viruses by vascular puncture inoculation

    Science.gov (United States)

    Vascular puncture inoculation (VPI) of plant viruses previously has been conducted either manually or by use of a commercial engraving tool and laboratory-fabricated needle arrays. In an effort to improve this technique, a linear-motion tattoo machine driving industry-standard needle arrays was tes...

  2. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  3. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    Science.gov (United States)

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  4. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Transforaminal Lumbar Puncture: An Alternative Technique in Patients with Challenging Access.

    Science.gov (United States)

    Nascene, D R; Ozutemiz, C; Estby, H; McKinney, A M; Rykken, J B

    2018-05-01

    Interlaminar lumbar puncture and cervical puncture may not be ideal in all circumstances. Recently, we have used a transforaminal approach in selected situations. Between May 2016 and December 2017, twenty-six transforaminal lumbar punctures were performed in 9 patients (25 CT-guided, 1 fluoroscopy-guided). Seven had spinal muscular atrophy and were referred for intrathecal nusinersen administration. In 2, CT myelography was performed via transforaminal lumbar puncture. The lumbar posterior elements were completely fused in 8, and there was an overlying abscess in 1. The L1-2 level was used in 2; the L2-3 level, in 10; the L3-4 level, in 12; and the L4-5 level, in 2 procedures. Post-lumbar puncture headache was observed on 4 occasions, which resolved without blood patching. One patient felt heat and pain at the injection site that resolved spontaneously within hours. One patient had radicular pain that resolved with conservative treatment. Transforaminal lumbar puncture may become an effective alternative to classic interlaminar lumbar puncture or cervical puncture. © 2018 by American Journal of Neuroradiology.

  6. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  7. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  8. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  9. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  10. CT-guided diagnostic interventions for classification of focal hepatic lesions: A comparison of 14 G- and 18 G-large bore cutting needles; CT-gesteuerte perkutane Biopsien zur Klassifizierung von fokalen Leberlaesionen: Vergleich zwischen 14 G- und 18 G-Stanzbiopsienadeln

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Piroth, W.; Staatz, G.; Adam, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1999-07-01

    Purpose: Analysis and comparison of CT-guided 14- and 18-gauge cutting needle biopsies to accurately assess focal liver disease. Methods: The data of 272 CT-guided biopsies in 268 patients were evaluated retrospectively with regard to sensitivity, specificity and complication rate of the chosen needle caliber in differentiating between benign and malignant disease as well as in the ability to determine specific cell types in the various disorders. A 14-gauge (G) needle was used in 101 (37.1%) cases, in 18-g needle biopsy was performed in 171 (62.9%) cases. The Fisher exact test was employed for statistical analysis. Results: Cutting needle biopsy yielded sufficient histologic material in 267 of 272 (98.2%) cases. Correct diagnosis of malignancy was established in 178 of 191 (93.2%) lesions, 73 of 76 (96.1%) disorders were accurately defined as benign, resulting in an overall value of 94.0% (251 of 267). Of these 251 biopsies a definite histological diagnosis could be determined in 90.6% of the cases employing a 14 G needle and in 90.3% using an 18-g needle. The sensitivity, specificity and rate of complications were 94.8%, 92.0%%, 3.0% for the 14-g needle and 92.7%, 97.6%, 0.6% for the 18-g needle, respectively. There were no statistically significant differences with regard to the needle size. Conclusions: CT-guided biopsy of hepatic lesions with the 18-g biopsy needle is of equivalent diagnostic accuracy when compared with the 14-g needle. (orig.) [Deutsch] Ziel: Analyse und Vergleich CT-gesteuerter Fein- und Grobstanzbiopsien zur definitiven Abklaerung unklarer fokaler Leberveraenderungen. Methoden: Die Daten von insgesamt 272 CT-gefuehrten Punktionen an 268 Patienten wurden retrospektiv hinsichtlich Sensitivitaet, Spezifitaet und Komplikationsrate zur Dignitaetsbestimmung und Faehigkeit zur artdiagnostischen Einordnung unter Beruecksichtigung der Groesse der gewaehlten Punktionsnadel ueberprueft und ausgewertet. In 101 (37,1%) Faellen wurde eine 14 Gauge (G

  11. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  12. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  13. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  14. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  15. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  16. Prospective evaluation of the radiologist's hand dose in CT-guided interventions

    International Nuclear Information System (INIS)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J.; Kropf, S.; Nekolla, E.A.; Wieners, G.

    2013-01-01

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  17. Clinical Feasibility and Usefulness of CT Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage in Emergency Patients with Acute Obstructive Cholangitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyung [Sam Anyang Hospital, Anyang (Korea, Republic of)

    2009-04-15

    To evaluate the feasibility of CT fluoroscopy (CTF)-guided percutaneous transhepatic biliary drainage (PTBD) in emergency patients with acute obstructive cholangitis. The study included 28 patients admitted to the emergency center due to obstructive jaundice and found to require urgent biliary drainage, as well as judged to have a suitable peripheral bile duct for a CTF-guided puncture (at least 4 mm in width). Prior to the CTF-guided puncture, a CT scan was performed to evaluate bile duct dilatation and the underlying causes of biliary obstruction. If the patient was judged to be a suitable candidate, a CTF-guided PTBD was performed in the same CT unit without additional fluoroscopic guidance. Technical feasibility of the procedure was investigated with the evaluation of overall success rate and causes of failure. A hepatic puncture was attempted at the left lobe in 23 patients and right lobe in five patients. The procedure was successful in 24 of 28 patients (86%) Successful biliary puncture was achieved on the first attempt in 16 patients, the second attempt in five patients, and the third attempt in three patients. The causes of failure included guide wire twisting in one patient, biliary puncture failure in two patients, and poor visualization of the guide wire in one patient. There were no significant procedure-related complication. The CTF-guided PTBD is technically feasible and highly successful in patients judged to have a suitable indication. Moreover, although the procedure is unfamiliar and inconvenient to interventionalists, it has economical advantages in that it saves time and manpower. We believe this method can be used in the emergency patients requiring urgent biliary drainage as an alternative for the fluoroscopy-guided PTBD.

  18. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  19. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Cohen, D.; Bruckheimer, E.; Bachar, G. N.; Konstantinovsky, R.; Birk, E.; Atar, E.

    2016-01-01

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  20. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A. [Soreq NRC, Radiation Protection Domain (Israel); Cohen, D.; Bruckheimer, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Bachar, G. N.; Konstantinovsky, R. [Rabin Medical Center, Department of Diagnostic Radiology (Israel); Birk, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Atar, E., E-mail: elia@clalit.org.il [Rabin Medical Center, Department of Diagnostic Radiology (Israel)

    2016-05-15

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  1. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    International Nuclear Information System (INIS)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-01-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occured: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders. (orig.) [de

  2. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  3. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  4. Nodular fasciitis of the face diagnosed by US-guided core needle biopsy: a case report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Kwon, Sun Young

    2006-01-01

    We report here on a case of nodular fasciitis (NF) that was diagnosed by ultrasonography (US)-guided core needle biopsy in a 31-year-old man, and we include the US and computed tomographic (CT) findings and the histopathologic findings at US-guided core needle biopsy (CNB). We suggest that high-resolution US is useful for the detailed evaluation of NF in the superficial regions, such as the face, and US-guided CNB is useful for the definitive histologic diagnosis of NF without causing scarring

  5. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.

  6. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  7. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  8. Transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma located in the subphrenic region of liver

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    2000-01-01

    The purpose of this study is to evaluate the feasibility of transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma (HCC, 15 lesions) located in the subphrenic region and untreatable by ultrasonography-guided PEIT. The HCC was localized on Lipiodol CT image with a graduated grid system. We advanced a PEIT needle in a stepwise fashion, perpendicularly to the major axis of body through the lung with intermittent localization scans to position the tip of the needle in the lesion. Ethanol was injected with monitoring scans obtained after incremental volumes of injection, until perfusion was judged to be complete. A total of 20 CT-PEIT sessions were performed. The average number of needles passed from skin to liver in each CT-PEIT session was 2.7, the average volume of ethanol injected was 11.7 ml, and the average time required was 53.6 minutes. Complete perfusion of the lesion by ethanol was achieved in all lesions with only a single or double CT-PEIT procedure without severe complications. Local recurrence was detected in 3 to 15 followed up lesions for 14 months on average. In conclusion, transpulmonary CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC located in the subphrenic region. (author)

  9. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  10. CT Fluoroscopy-Guided Transsacral Intervertebral Drainage for Pyogenic Spondylodiscitis at the Lumbosacral Junction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan); Kamono, Masahiro, E-mail: kamono@tsc.u-tokai.ac.jp; Taoda, Akiko, E-mail: acco@is.icc.u-tokai.ac.jp; Higaki, Megumu, E-mail: higaki@hachioji-hosp.tokai.ac.jp [Tokai University School of Medicine, Department of General Internal Medicine, Tokai University Hachioji Hospital (Japan); Hasebe, Terumitsu, E-mail: hasebe@tokai-u.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan)

    2017-01-15

    PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsy needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.

  11. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  12. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    Science.gov (United States)

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  13. A case of transitional cell carcinoma associated with pericalyceal diverticulum diagnosed by CT guided percutaneous cystgraphy

    International Nuclear Information System (INIS)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira; Anno, Hirofumi; Hujita, Tamio

    1983-01-01

    Computed tomography (CT) performed on a 42-year-old male patient with a chief complaint of hematuria revealed a renal cyst with a thickened and irregularly shaped wall. CT with contrast medium injected into the cyst by puncture under CT guide detected tumors on the cystic wall preoperatively. (Ueda, J.)

  14. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    Science.gov (United States)

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  16. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  17. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  18. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  19. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  20. Percutaneous Transhepatic Catheterization of the Portal Vein: A Combined CT- and Fluoroscopy-Guided Technique

    International Nuclear Information System (INIS)

    Weimar, Bernd; Rauber, Klaus; Brendel, Mathias D.; Bretzel, Reinhard G.; Rau, Wigbert S.

    1999-01-01

    Combined CT- and fluoroscopy-guided transhepatic portal vein catheterization was performed in 44 patients selected for pancreatic islet cell transplantation. The method allowed catheterization with a single puncture attempt in 39 patients. In four patients two attempts and in one patient four attempts were necessary. One minor hematoma of the liver capsule occurred that required no further treatment. Compared with other methods the average number of puncture attempts was reduced

  1. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  2. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    Science.gov (United States)

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  3. Role of [18F]fluorodeoxyglucose positron emission tomography-computed tomography, sonography, and sonographically guided fine-needle aspiration biopsy in the diagnosis of axillary lymph nodes in patients with breast cancer: comparison of diagnostic performance.

    Science.gov (United States)

    Sohn, Yu-Mee; Hong, Il Ki; Han, Kyunghwa

    2014-06-01

    The aim of this study was to compare the diagnostic performance of [(18)F]fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) with that of sonography and sonographically guided fine-needle aspiration (FNA) for determining the preoperative axillary lymph node (ALN) status and to evaluate the factors related to false-negative PET-CT, sonographic, and FNA results in ALN staging of invasive ductal carcinoma. From March 2009 to July 2012, 226 patients had a diagnosis of primary breast cancer. Among these patients, 107 constituted the study population after exclusion of transferred patients and patients with breast cancer other than invasive ductal carcinoma. The diagnostic performance of the modalities was compared with pathologic reports. Univariate and multivariate analyses were used to evaluate the relationship between clinicopathologic factors (symptoms, T stage, hormone receptors, and histologic grade), false-negative results, and true-negative results on PET-CT, sonography, and FNA. Of the 107 patients, 45 (42.1%) had positive results on final pathologic analysis of ALNs. Sonographically guided FNA had a significantly higher specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve than sonography and PET-CT (P < .01). When sonography and PET-CT were combined, the sensitivity was significantly improved (P = .019) compared with sonography alone. When FNA and PET-CT were combined, the sensitivity and negative predictive value were significantly increased compared with each modality (P < .01). Sonographically guided FNA was found to be an excellent diagnostic tool for preoperative evaluation of the ALN status. To obviate the step of sentinel lymph node biopsy for determining the ALN status, combined evaluation of ALNs by these modalities may be more complementary than the use of a single modality. © 2014 by the American Institute of Ultrasound in Medicine.

  4. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  5. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Hirose, Takashi; Mori, Kiyoshi; Machida, Suguru; Tominaga, Keigo; Yokoi, Kohei; Adachi, Mitsuru

    2000-01-01

    The purpose of this study was to evaluate the usefulness of computed tomographic (CT) fluoroscopy-guided transthoracic needle biopsy (TTNB) with an 18-gauge automatic biopsy gun for the diagnosis of pulmonary nodules. Between March 1996 and January 1998, 50 patients in whom pulmonary lesions could not be diagnosed cytopathologically with fiberoptic bronchoscopy or were not clearly visualized with fluoroscopy underwent CT fluoroscopy-guided TTNB. Final pathological diagnoses were 23 lung carcinomas, five pulmonary metastases and 22 benign lesions. Sufficient tissue for analysis was obtained from 48 of the 50 lesions (96%). The overall diagnostic yield of CT fluoroscopy-guided TTNB was 90%. The sensitivity, specificity and accuracy for malignancy were 89%, 100% and 94%, respectively. In 20 of the 22 cases (91%) of benign lesions, histological analysis yielded correct and specific diagnoses. Complications occurred in 22 of the 50 cases (44%). The most common complication was pneumothorax, which occurred in 21 of the 50 cases (42%). Chest tube insertion was required in 6 (12%). Although CT fluoroscopy could not decrease the complication rate, CT fluoroscopy-guided TTNB with an automatic biopsy gun appears to be a promising technique for diagnosing pulmonary lesions, particularly benign lesions. (author)

  6. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  7. CT guided celiac plexus and splanchnic nerve neurolysis : the modified anterior approach

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Ym, Seong Hee; Lee, Jin Hee

    1997-01-01

    Since it was first described by Kappis, celiac plexus neurolysis (CPN) has been performed under fluoroscopic guidance by anesthetists or surgeons for the relief of intractable pain caused by upper abdominal malignancy. Recently, however, several groups have reported a computed tomography (CT)-guided technique that increased the safety of the blocking procedure and improved its results. The authors present a new technique CT-guided celiac plexus and splanchic nerve block, to be used simultaneously with a modified anterior approach. Using CT to guide needle tip placement, an anterior approach that permitted direct neurolysis of the celiac ganglia and splanchnic nerve was developed

  8. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  9. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  10. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  11. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  12. Technical measurement of small fission gas inventory in fuel rod with laser puncturing system

    International Nuclear Information System (INIS)

    Kim, Hee Moon; Kim, Sung Ryul; Lee, Byoung Oon; Yang, Yong Sik; Baek, Sang Ryul; Song, Ung Sup

    2012-01-01

    The fission gas release cause degradation of fuel rod. It influences fuel temperature and internal pressure due to low thermal conductivity. Therefore, fission gas released to internal void of fuel rod must be measured with burnup. To measure amount of fission gas, fuel rod must be punctured by a steel needle in a closed chamber. Ideal gas law(PV=nRT) is applied to obtain atomic concentration(mole). Steel needle type is good for large amount of fission gas such as commercial spent fuel rod. But, some cases with small fuel rig in research reactor for R/D program are not available to use needle type because of large chamber volume. The laser puncturing technique was developed to solve measurement of small amount of fission gas. This system was very rare equipment in other countries. Fine pressure gage and strong vacuum system were installed, and the chamber volume was reduced at least. Fiber laser was used for easy operation

  13. CT-guided periradicular therapy in cervical and lumbar radicular syndromes

    International Nuclear Information System (INIS)

    Nian Dingfang; Zhou Jun; Li Wenhua; Cao Qingxuan; Xia Baosu; Apitzsch, D.E.

    2007-01-01

    Objective: To evaluate the effectiveness of CT-guided periradicular therapy (PRT) in cervical and lumber radicular syndromes. Methods: Seventy two cases of cervical and lumbar radicular syndromes were treated by CT-guided PRT. During PRT, 10-20 mg of Triamhexal and 3-4 ml of Carbostesin 0.25%(Bupivacainhydrochlorid) were injected into the space around the corresponding spinal root, once a week, all together six times as a course. Results: Four hundreds and forty six PRT procedures were carried out in 72 patients having a successful puncture and a satisfying spread of Triamhexal and Carbostesin around the spinal nerve root space for every time. After 6 to 24 months follow up, 62 patients showed a significant pain reduction or complete disappearance. Moderate improvement was not noted in 6 and no improvement in 4. The effective rate was 94.4% without any correlative complication. Conclusions: CT-guided PRT is an effective, easy and safe procedure to treat patients with refractory cervical or lumbar radicular pain syndromes. (authors)

  14. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  15. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  16. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  17. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  18. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  19. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  20. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  1. CT-guided conformal cryoablation for peripheral NSCLC: Initial experience

    International Nuclear Information System (INIS)

    Zhang, Xiao; Tian, Jinlin; Zhao, Lei; Wu, Bin; Kacher, Daniel S.; Ma, Xuyang; Liu, Shurong; Ren, Chao; Xiao, Yue-Yong

    2012-01-01

    Purpose: To study the feasibility of CT-guided and monitored percutaneous conformal cryoablation of Non-Small Cell Lung Cancer for patients who are not suitable for surgical resection. Materials and method: CT-guided percutaneous conformal cryoablation was performed on 46 patients with peripheral Non-Small Cell Lung Cancer. Patients with tumor sizes less than 3 cm in diameter were treated with double-needle clamping cryoablation, while the patients with 3–5 cm tumor sizes were treated with multiple-needle conformal cryoablation. CT was used to monitor the extent of cryoablation during the procedures. At month 1, 3, 6, 12, and 24 post-procedure, enhanced CT scans and/or PET-CT scans were performed to evaluate the impact of the therapy. Results: The average tumor CT values were 32 ± 10 HU and −21 ± 8 HU before and after cryoablation, respectively. The largest diameters of the lesions at month 1, 3, 6, 12, and 24 post-procedure were 2.63 ± 0.56 cm, 1.93 ± 0.51 cm, 1.55 ± 0.39 cm, 1.43 ± 0.40 cm, and 1.38 ± 0.38 cm, respectively, in patients with tumor diameter less than 3 cm, and 3.63 ± 0.39 cm, 2.98 ± 0.31 cm, 2.62 ± 0.32 cm, 2.54 ± 0.34 cm, and 2.56 ± 0.37 cm respectively in patients with the tumor diameters between 3 and 5 cm. At the 24th month, there were 36 cases of complete response (83.7%), 7 cases of partial response (16.3%), and no cases of stable disease or progressive disease. 3 patients died due to multiple metastases. Conclusion: CT-guided percutaneous conformal cryoablation is a safe, effective, and minimally invasive therapeutic method for peripheral lung cancer.

  2. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  3. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  4. Diagnosis of sclerosing hemangioma of lung: Don′t rely on fine-needle aspiration cytology diagnosis alone

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available Sclerosing hemangioma is a rare variety of benign pulmonary neoplasm. It usually presents as asymptomatic, solitary, peripheral, circumscribed lesions in middle-aged women. Here, we describe a 46-year-old woman presenting to us for evaluation of right parahilar lung mass. Previous chest radiography done 10 years back showed a lung mass of almost similar size. Computed Tomography (CT-guided fine-needle aspiration cytology (FNAC was suggestive of adenocarcinoma of lung. A well-circumscribed, capsulated, ovoid mass measuring 5.6 cm × 4 cm × 3 cm, adjacent to the transverse fissure of the right lung was excised by lateral thoracotomy. Histopathological examination along with immunohistochemistry was suggestive of sclerosing hemangioma of lung. A pathologist must consider the clinicoradiological features before coming to a final diagnosis of lung malignancy from FNAC. Whenever there is any confusion regarding lung mass, thoracotomy must be done for arriving at an exact diagnosis from histopathology.

  5. Computed tomography-guided needle aspiration and biopsy of pulmonary lesions - A single-center experience in 1000 patients

    Energy Technology Data Exchange (ETDEWEB)

    Poulou, Loukia S.; Tsagouli, Paraskevi; Thanos, Loukas [Dept. of Medical Imaging and Interventional Radiology, General Hospital of Chest Diseases ' Sotiria' , Athens (Greece)], e-mail: ploukia@hotmail.com; Ziakas, Panayiotis D. [Program of Outcomes Research, Div. of Infectious Diseases, Warren Alpert Medical School, Brown Univ., RI, and Div. of Infectious Diseases, Rhode Island Hospital, Rhode Island (United States); Politi, Dimitra [Dept. of Cythopathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece); Trigidou, Rodoula [Dept. of Pathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece)

    2013-07-15

    Background: Computed tomography (CT)-guided fine needle aspiration (FNA) and biopsies are well-established, minimally invasive diagnostic tools for pulmonary lesions. Purpose: To analyze retrospectively the results of 1000 consecutive lung CT-guided FNA and/or core needle biopsies (CNB), the main outcome measures being diagnostic yield, and complication rates. Material and Methods: Patients considered eligible were those referred to our department for lung lesions. The choice of FNA, CNB, or both was based upon the radiologist's judgment. Diagnostic yield was defined as the probability of having a definite result by cytology/histology. Results: The study included 733 male patients and 267 female patients, with a mean (SD) age of 66.4 (11.4) years. The mean (SD) lesion size was 3.7 (2.4) cm in maximal diameter. Six hundred and forty-one (64%) patients underwent an FNA procedure, 245 (25%) a CNB, and 114 (11%) had been subjected to both. The diagnostic yield was 960/994 (96.6%); this decreased significantly with the use of CNB only (odds ratio [OR] 0.32; 95% CI 0.12 - 0.88; P = 0.03), while it increased with lesion size (OR 1.35; 95% CI 1.03 - 1.79; P = 0.03 per cm increase). In 506 patients (52.7%), a malignant process was diagnosed by cytopathology/histology. The complication rate reached 97/1000 (9.7%); complications included: hemorrhage, 62 (6.2%); pneumothorax, 28 (2.8%); hemorrhage and pneumothorax, 5 (0.5%); and hemoptysis, 2 (0.2%). It was not significantly affected by the type of procedure or localization of the lesion. The overall risk for complications was three times higher for lesions <4 cm (OR 3.26; 95% CI 1.96 - 5.42; P < 0.001). Conclusion: CT-guided lung biopsy has a high diagnostic yield using FNA, CNB, or both. The CNB procedure alone will not suffice. Complication rates were acceptable and correlated inversely with lesion size, not localization or type of procedure.

  6. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Mikosinski, S.; Oszukowska, L.; Makarewicz, J.; Adamczewski, Z.; Lewinski, A.; Pomorski, L.; Sporny, S.

    2006-01-01

    Introduction: Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. Material and methods: The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and 131I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15 - 711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94 - 100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Results: Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. Conclusions: 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes

  7. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  8. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  9. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  10. CT-guided percutaneous treatment of solitary pyogenic splenic abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Pombo, F. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Suarez, I. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Marini, M. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Arrojo, L. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Echaniz, A. [Dept. of Internal Medicine, Hospital Juan Canalejo, La Coruna (Spain)

    1991-08-01

    Six patients with solitary pyogenic splenic abscesses treated by CT-guided percutaneous drainage (by catheter or needle), are presented. There were 3 unilocular, purely intrasplenic abscesses and 3 complex lesions with loculations and perisplenic involvement. Percutaneous drainage and intravenous antibiotics were curative in 4 patients. In the other 2, who had multiloculated abscesses, despite initially successful drainage, splenectomy was performed because of intractable left upper quadrant pain in one case and persistent fever and drainage of pus after 30 days in the other. These patients also developed large, sterile left pleural effusions. Solitary pyogenic splenic abscesses - particularly if uniloculated - can be effectively treated by CT-guided percutaneous drainage. (orig.)

  11. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  12. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  13. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  14. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  15. CT-guided celiac plexus block with absolute alcohol : the anterior approach

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Jang, Young Ik; Kim, Jeong Hoi; Ym, Seong Hee; Lee, Jin Hee; Han, Young Min; Kim, Chong Soo; Choi, Ki Chul

    1997-01-01

    To evaluate the safety and efficacy of CT-guided celiac plexus block (CPB) using an anterior approach, and to determine the role of CT in this procedure. CPB was attempted in 15 patients(10 men and 5 women;mean age, 62.3 years) with intractable upper abdominal pain due to terminal malignancy of the pancreas, liver, bowel,and kidney. To permit an anterior approach, patients lied supine on the CT scan table during the procedure. One or two 21-guage needles were placed just anterior to the diaphragmatic crus at or between the levels of the celiac and superior mesenteric arteries and 10-40ml of 99.9% alcohol was injected. Pain relief following the procedure was assessed and pain was graded on a visual analogue scale (VAS) from 0 to 10. There were no technical failures and no neurologic or hemorrhagic complications. Abdominal pain during alcohol injection occurred in all patients, and transient hypotension in three. One patient with recurrent cancer of the pancreatic head died of sepsis five days after the procedure;the cause of sepsis was difficult to determine, but there was thought to be a biliary source of infection. Two days after block, 13 of 15 procedures(86.7%) had produced at least partial pain relief;in 12 patients, relief was good. With CT guidance, more directed positioning of the needle is possible, allowing alcohol to be deposited in specific ganglion areas. CT-guided celiac plexus block using an anterior approach was an easy and effective way of reducing intractable upper abdominal pain due to terminal malignancies. CT guidance allowed precise needle placement and a safer procedure

  16. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  17. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  18. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  19. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    International Nuclear Information System (INIS)

    Datir, A.; Connell, D.

    2010-01-01

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT-guided

  20. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    Energy Technology Data Exchange (ETDEWEB)

    Datir, A., E-mail: apdatir@gmail.co [Jackson Memorial Hospital, Miami, FL (United States); Connell, D. [Royal National Orthopaedic Hospital NHS Trust, Stanmore, Middlesex (United Kingdom)

    2010-01-15

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT-guided

  1. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  2. Prospective evaluation of the radiologist's hand dose in CT-guided interventions; Prospektive Evaluation der Handdosis des Radiologen im Rahmen von CT-gestuetzten Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Kropf, S. [Magdeburg Univ. (Germany). Dept. of Biometry and Medical Informatics; Nekolla, E.A. [The Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Radiation Protection and Health; Wieners, G. [Charite CVC, Berlin (Germany). Dept. of Radiology

    2013-11-15

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  3. Risk factors of pneumothorax in percutaneous fine needle aspiration biopsy of the lung

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Park, Kwang Joo; Shin, Hyung Cheol; Kwon, Ryang; Jo, Byung June; Oh, Sei Jung; Ahn, Chang Su; Kim, Hyung Jung

    1997-01-01

    Percutaneous fine needle aspiration biopsy is known to be a useful diagnostic method for the diagnosis of various pulmonary diseases. Its diagnostic yield is high, and it is safe, but complications such as pneumothorax can occasionally occur. We reviewed the complications arising after needle aspiration biopsy and analyzed the risk factors of pneumothorax. The medical records and radiographic studies of 157 patients with various pulmonary diseases who underwent needle aspiration biopsy of the lung between 1990 and 1996 were retrospectively reviewed. The clinical features, treatment, and courses of complications were reviewed, and risk factors of pneumothorax such as depth and size of lesion, diameter of needle, number of punctures, and obstructive pulmonary abnormalities were analyzed. Complications occurred in 40 of 157cases(25.5%), namely pneumothorax in 26(16.6%), hemoptysis in 11(7%), hemothorax in two(1.3%), and recurrence of malignancy at the site of aspiration in one(0.6%). When the patients were divided into three groups according to depth of lesion, there were significant difference in the incidence of pneumothorax;the results were as follows:less than 2cm, 12.9%;between 2 and 4cm, 24.1%;and larger than 4cm, 57.1%(p<0.05). In pulmonary function testing, FVC(Forced Vital Capacity) of patients with pneumothorax was less than that of patients without(2.6±0.9L vs 3.1±0.8L, p<0.05), but FEV1(Forced Expiratory Volume in 1 second), FEV1%(percentage of predicted FEV1), FEV1/FVC, and FVC% (percentage of predicted FVC) were not different between the two groups. The incidence of pneumothorax in patients with pleura-at-tached lesion (9%) was lower than that of those with non-attached lesion(26%, p=3D0.01). The age of patients, size of lesion, diameter of the needle, guidance methods and number of aspirations showed no significant relationship with pneumothorax. In needle aspiration biopsy of the lung, depth of lesion and passage of a needle through aerated lung are

  4. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  5. Development of the robot system to assist CT-guided brain surgery

    International Nuclear Information System (INIS)

    Koyama, H.; Funakubo, H.; Komeda, T.; Uchida, T.; Takakura, K.

    1999-01-01

    The robot technology was introduced into the stereotactic neurosurgery for application to biopsy, blind surgery, and functional neurosurgery. The authors have developed a newly designed the robot system to assist CT-guided brain surgery, designed to allow a biopsy needle to reach the targget such as a cerebral tumor within a brain automatically on the basis of the X,Y, and Z coordinates obtained by CT scanner. In this paper we describe construction of the robot, the control of the robot by CT image, robot simulation, and investigated a phantom experiment using CT image. (author)

  6. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  7. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  8. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  9. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  10. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    Science.gov (United States)

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  11. Extrapeural locating method: significance in CT-guided transthoracic pulmonary biopsy

    International Nuclear Information System (INIS)

    Tang Guangjian; Wang Rengui; Liu Jianxin; Sun Jingtao

    2008-01-01

    Objective: To evaluate the usefulness of extrapleural locating method in CT-guided transthoracic pulmonary biopsy to prevent or reduce the size of peumothorax. Methods: One hundred and fifteen cases of CT-guided transthoracic pulmonary biopsy with the pulmonary lesions not in direct contact with the pleura were selected. Of 115 cases, 46 were performed with extrapleural locating method (EPL) and 69 cases with lesion edge locating method (LEL). Taking the maximum distance between the partial and visceral pleura (MPVD) measured on the CT image after the procedure as the index of the volume of pneumothorax. The incidence and volume of pneumothorax of both groups were compared and statistically analysed with R x C Chi-Square test. The retention time of the biopsy needle in the lung parenchyma of the two group was documented and the average time was calculated in each group. Results: The incidence of pneumothorax was 45.7% (21/46), median 0.4 cm with EPL group, and 66.7% (46/69) and median 0.3cm with LEL group. When the distance between the lesion and pleura was equal or smaller than 2 cm (≤2cm), the incidence of pneumothorax was 39.4% (13/33) with EPL group and 73.2% (30/41) with LEL group, and the difference of incidence and volume of the pneumothorax between two groups was statistically significant(χ 2 =9.981, P=0.019). When the distance was larger than 2 cm (>2 cm), the incidence and volume of pneumothorax between two groups were not significant statistically. The average retention time of the biopsy needle in the lung parenchyma was (7.2 ± 1.8) s with EPL group and (58.3 ± 11.6) s with LEL group. Conclusion: The extrapleural locating method can reduce effectively the retention time of the biopsy needle in the lung parenchyma and the incidence and volume of pneumothorax in CT-guided transthoracic pulmonary biopsy. (authors)

  12. Fibroadenoma: can fine needle aspiration biopsy avoid short term follow-up?

    Science.gov (United States)

    Leconte, I; Abraham, C; Galant, C; Sy, M; Berlière, M; Fellah, L

    2012-10-01

    To confirm whether fine needle aspiration biopsy (FNAB) can avoid close monitoring, a source of worry for women patients with a suspected fibroadenoma found by ultrasound, and requiring their compliance. Over 39months, 427 nodules with a diagnosis of fibroadenoma were sampled in 372 patients using ultrasound-guided FNAB. The sonographic appearance of all the nodules suggested BI-RADS category 3 fibroadenomas. The mean size of the fibroadenomas was 9mm. The mean duration of follow-up was 29.7months. Seven nodules had atypical cytology: a microbiopsy and/or excision found a simple fibroadenoma (n=3), mastitis (n=1), a fibroadenoma associated with a papilloma (n=1), fibrosis (n=1) and normal tissue (n=1). Seven other nodules were resected during treatment for synchronous cancer, and were diagnosed as fibroadenomas. Two hundred and seventy-six nodules were followed-up (121 patients were lost to follow-up [n=132]) and the appearance of 263 nodules (95.29%) was stable. Seven nodules, which had increased in size, underwent another FNAB or microbiopsy or surgery. Five nodules were not found again. The borders of one nodule showed modifications. The use of fine needle aspiration biopsy, interpreted by an experienced cytologist, means that short term follow-up of fibroadenomas can be avoided. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  14. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  15. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  16. CT-guided needle biopsy in the diagnosis of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue: a rare combination.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2015-01-01

    We represent a rare case of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT). The patient was a 66-year-old male presented with 1 month history of recurrent cough and hemoptysis. Chest CT showed solitary ground-glass opacity (GGO) in the upper lobe of the right lung and mediastinal lymph node enlargement in station 3p. A CT-guided transthoracic needle biopsy was performed. Tissue specimens of the GGO revealed a typical adenocarcinoma. Histopathologic diagnosis of mediastinal lymph node was extranodal marginal zone lymphoma of MALT. Because of its rarity, extranodal marginal zone lymphoma of MALT should be considered in the differential diagnosis when we encounter mediastinal lymphadenopathy in patients with lung adenocarcinoma.

  17. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  18. CT-guided percutaneous conformal cryoablation for lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yueyong, Xiao; Bin, Wu; Xiao, Zhang; Hongjun, Li; Da, Yu; Jie, Li; Jun, Li [Department of Radiology, PLA General Hospital, Beijing (China)

    2010-02-15

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  19. CT-guided percutaneous conformal cryoablation for lung carcinoma

    International Nuclear Information System (INIS)

    Xiao Yueyong; Wu Bin; Zhang Xiao; Li Hongjun; Yu Da; Li Jie; Li Jun

    2010-01-01

    Objective: To investigate the safety, efficacy and feasibility of CT-guided percutaneous conformal cryoablation for lung cancer. Methods: The inclusion criteria were: (1) Poor respiratory function and aged patients who can not bear the thoracic surgical operation. (2) Peripheral lung cancer involving the pleura and chest wall which can not be resected. (3) Residual tumor after other comprehensive treatment. (4) Focal lung cancer but the patient refused surgical resection. The exclusion criteria were: (1) Multifocal lesions. (2) Lesion close to mediastinum with possible risk of vessel injury. (3) Severe impairment of pulmonary functions, the maximum voluntary ventilation is less than 39%. (4) Repeated cough or dyspnea, can not cooperate with the procedure. (5) Poor systemic conditions, cachexia or bleeding. Totally, 76 lung carcinoma lesions on 66 patients were treated by CT-guided percutaneous conformal cryoablation using 17 G cryoprobes. The maximum diameters of the tumors ranged from 1.5 cm to 1.6 cm. For the tumors with the maximum diameter less than 3.0 cm, they were treated by double-needle clamping cryoablation. For those with the maximum diameter between 3.0 and 5.0 cm, they were treated by multiple-needle conformal cryoablation. For those with the maximum diameter larger than 5.0 cm, they were treated with multiple-needle conformal cyroablation, with the needle distance less than 1.5 cm. All the patients were followed-up 6 to 24 months after the procedure using contrast-enhanced CT to evaluate the tumor size and enhancement. Results: For 18 cases with the maximum diameters less than 3.0 cm, CT scan during the procedure showed that the frozen areas extended beyond the edge of the lesions more than 1.0 cm, the lesion attenuated, narrow-band-like encircled translucency around the lesions and 'target sign' with ground-glass density of the peripheral lung tissue. There was no enhancement during the first 1 st, 3 rd month follow-up, only fibrosis scar in 6 th

  20. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  1. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  2. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  3. [Clinical value of CT-guided high frequency-induced thermotherapy as a treatment for intrahepatic cholangiocarcinoma].

    Science.gov (United States)

    Fan, Wei-Jun; Zhang, Liang; Gu, Yang-Kui; Wang, Li-Gang; Ouyang, Yu-Shu

    2008-07-01

    To evaluate the therapeutic effect of CT-guided high frequency-induced thermotherapy (HiTT) for intrahepatic cholangiocarcinoma. Seventeen patients of intrahepatic cholangiocarcinoma with 21 lesions underwent comprehensive treatment with HiTT as the principle approach. As to the patients with obstructive jaundice, percutaneous trans-hepatic cholangial drainage (PTCD) or bile duct endoprosthesis placement was performed first to improve the liver function, then HiTT was performed; and patients without obstructive jaundice underwent CT-guided HiTT directly, 1-2 weeks later, chemotherapy was given for 4 - 6 courses. CT scan 1 week after HiTT showed a short-term achievement rate of 100% (17/17), and the single puncture in situ ablation rate was 76.1% (16/21). The average life span in the near future was 13.5 months. The adverse effects included topo-bleeding, pain after procedure, liver function damage, defervescence, etc. All the patients recovered after symptomatic treatment. The clinical value of CT-guided HiTT for intrahepatic cholangiocarcinoma is obvious.

  4. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    NARCIS (Netherlands)

    Konge, L.; Vilmann, P.; Clementsen, P.; Annema, J. T.; Ringsted, C.

    2012-01-01

    Background and study aims: Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was

  5. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    Science.gov (United States)

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  6. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  7. CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection

    International Nuclear Information System (INIS)

    Klass, Darren; Marshall, Tom; Toms, Andoni

    2009-01-01

    Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heated to 90 C for 2 min for two cycles by using a Cosman SMK TC-10 RF electrode. This was preceded by a bolus of room temperature sterile water (10 ml) injected through a 26G curved spinal needle into the exit foramen and adjacent epidural space for neuroprotection. The age of the patient, sex, lesion location, biopsy results and complications were recorded. All the biopsies (n = 7) demonstrated histological features of osteoid osteoma. All the procedures were technically successful. Clinical success was assessed up to 3 years post procedure. There was an 85% clinical success rate (6 of the 7 patients), with recurrence of a lesion at 6 months, necessitating a repeat procedure (successful). CT-guided percutaneous RF ablation of spinal osteoid osteoma preceded by bolus of sterile water, injected through a spinal needle into the exit foramen and adjacent epidural space for neuroprotection, is a safe and effective procedure. (orig.)

  8. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  9. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  10. Fabrication of Bonding-Type Hollow Microneedle Array by Injection Molding and Evaluation of its Puncture Characteristics

    Science.gov (United States)

    Ogai, Noriyuki; Sugimura, Ryo; Tamaru, Takuya; Takiguchi, Yoshihiro

    A microneedle array which consists from small needles compared to a conventional metal injection needle is expected as a low invasive transdermal medical treatment device, and many fabrication approach have been conducted. In this study, we fabricated plastic hollow microneedle array by a fabrication method based on the combination of injection molding, bonding and assembly techniques. To evaluate puncture characteristics of the fabricated needle, we measured a puncture force to silicone rubber by experimental equipment using loadcell and automatic stage. Furthermore, we propose and demonstrate a new method to measure actual punctured depth from punctured trace on the needle surface modified by O2 plasma treatment.

  11. Lumbar punction: comparison between an atraumatic and a traumatic punction needle

    Directory of Open Access Journals (Sweden)

    Tina Bregant

    2017-03-01

    Full Text Available Background: Lumbar puncture is a standardized, routine diagnostic procedure in the diagnosis of neurological diseases. Post-duarl puncture headache (PDPH is a common complication which occurs in 10 to 30 % of patients. Although the incidence of PDPH is much lower with the use of small, non-cutting needles, neurologists in Slovenia routinely use the classical traumatic spinal needles.Methods: In the article we provide an overview of a research concerned with the use of traumatic and atraumatic needles in the procedure with the emphasis on complications of the lumbar puncture. We present American and European recommendations for lumbar puncture procedure.Conclusions: International recommendations for neurologists advise the use of atraumatic spinal needles for lumbar puncture. We recommend to Slovenian neurologists to start using the atraumatic needles for elective lumbar punctures and hence provide neurological patients with better quality and cheaper long-term care.

  12. Accuracy and feasibility of frameless stereotactic and robot-assisted CT-based puncture in interventional radiology. A comparative phantom study

    International Nuclear Information System (INIS)

    Stoffner, R.; Widmann, G.; Bale, R.; Augschoell, C.; Boehler, D.

    2009-01-01

    Purpose: To compare the accuracy of frameless stereotactic and robot-assisted puncture in vitro based on computed tomography (CT) imaging with a slice thickness of 1, 3, and 5 mm. Materials and Methods: 300 punctures were carried out with help of the Atlas aiming device guided by the optical navigation system Stealth Station TREONplus and 150 punctures were guided by the robotic assistance system Innomotion. Conically shaped rods were punctured with Kirschner wires. The accuracy was evaluated on the basis of control CTs by measuring the Euclidean distance between the wire tip and target and the normal distance between the target and wire. Results: With the Stealth Station a mean Euclidean distance of 1.94±0.912, 2.2±1.136, and 2.74±1.166 mm at a slice thickness of 1, 3 and 5 mm, respectively, was reached. The mean normal distance was 1.64±0.919, 1.84±1.189, and 2.48±1.196 mm, respectively. The Innomotion system resulted in a mean Euclidean distance of 1.69±0.772, 1.91±0.673, and 2.30±0.881 mm, respectively, while the mean normal distance was (1.42±0.78), 1.60±0.733, and 1.98±1.002 mm, respectively. A statistical significance between accuracies with both systems with 1 mm and 3 mm slices could not be detected (p > 0.05). At a slice thickness of 5 mm, the robot was significantly more accurate, but not as accurate as when using thinner slices (p < 0.05). The procedure time is longer for the Innomotion system (∝30 vs. ∝18 min), and the practicability is higher with the Stealth Station. (orig.)

  13. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  14. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25G quince, 27G quince and 27G whitacre spinal needles

    International Nuclear Information System (INIS)

    Shaikh, J.M.; Memon, M.; Khan, M.

    2008-01-01

    To compare the frequency and severity of post dural puncture headache in obstetric patients using 25G Quincke, 27G Quincke and 27G Whitacre spinal needles. Comparative, randomized, double-blind, interventional study. 480 ASA I-II full term pregnant women, 18 to 45 years of age, scheduled for elective Caesarean section, under spinal anaesthesia, were randomized into three groups: Group I (25G Quincke spinal needle: n=168), Group II (27G Quincke spinal needle: n=160) and Group III (27G Whitacre spinal needle: n=152). Spinal anaesthesia was performed with 1.5-2.0 ml 0.75% hyperbaric bupivacaine using 25G Quincke spinal needle (Group I), 27G Quincke spinal needle (Group II) and 27G Whitacre spinal needle (Group III) at L3-4 inter-vertebral space. Each patient was assessed daily for four consecutive days following Caesarean section. Frequency and severity and of postdural puncture headache (PDPH) were recorded. Data were analyzed using SPSS-11. Frequency of PDPH following the use of 25G Quincke (Group I), 27G Quincke (Group II) and 27G Whitacre (Group III) spinal needles was 8.3% (14/168), 3.8% (6/160) and 2.0% (3/152) respectively. In Group I, PDPH was mild in 5 patients, moderate in 7 patients and severe in 2 patients. In Group II, it was mild in 2, moderate in 3 and severe in 1 patient. In group III, it was mild in 2 and moderate in 1 patient. Severe PDPH did not occur in Group III. Most of the patients with PDPH developed it on 1st and 2nd postoperative day. When using a 27G Whitacre spinal needle, the frequency and severity of PDPH was significantly lower than when a 25G Quincke or 27G Quincke needle was used. (author)

  15. Application of Real-Time 3D Navigation System in CT-Guided Percutaneous Interventional Procedures: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Priya Bhattacharji

    2017-01-01

    Full Text Available Introduction. To evaluate the accuracy of a quantitative 3D navigation system for CT-guided interventional procedures in a two-part study. Materials and Methods. Twenty-two procedures were performed in abdominal and thoracic phantoms. Accuracies of the 3D anatomy map registration and navigation were evaluated. Time used for the navigated procedures was recorded. In the IRB approved clinical evaluation, 21 patients scheduled for CT-guided thoracic and hepatic biopsy and ablations were recruited. CT-guided procedures were performed without following the 3D navigation display. Accuracy of navigation as well as workflow fitness of the system was evaluated. Results. In phantoms, the average 3D anatomy map registration error was 1.79 mm. The average navigated needle placement accuracy for one-pass and two-pass procedures, respectively, was 2.0±0.7 mm and 2.8±1.1 mm in the liver and 2.7±1.7 mm and 3.0±1.4 mm in the lung. The average accuracy of the 3D navigation system in human subjects was 4.6 mm ± 3.1 for all procedures. The system fits the existing workflow of CT-guided interventions with minimum impact. Conclusion. A 3D navigation system can be performed along the existing workflow and has the potential to navigate precision needle placement in CT-guided interventional procedures.

  16. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  17. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  18. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  19. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  20. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    diagnosis of palpable breast lesions, in recent years two types of minimally invasive .... negative predictive value of FNAC as a diagnostic pro- cedure for the entire ... The earliest large scale use of Fine Needle aspiration. Cytology FNAC as a ...

  1. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  2. Automatic path proposal computation for CT-guided percutaneous liver biopsy.

    Science.gov (United States)

    Helck, A; Schumann, C; Aumann, J; Thierfelder, K; Strobl, F F; Braunagel, M; Niethammer, M; Clevert, D A; Hoffmann, R T; Reiser, M; Sandner, T; Trumm, C

    2016-12-01

    To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.

  3. Radiological and cytological correlation of neoplastic lesions of the breast diagnosed by fine needle aspiration biopsy guided with ultrasound at the Hospital San Juan de Dios in the year 2009

    International Nuclear Information System (INIS)

    Madriz Meza, Wendy P.

    2011-01-01

    Mortality from breast cancer has been increased, going on to occupy the first place of the malignant neoplasms in women with a percentage increase of over 45% in 10 years. A bibliographic search demonstrates that have not been performed works that allow to establish the clinical and radiological characteristics of the lesions who have been diagnosed as mammary neoplasms by fine needle aspiration biopsy at the Hospital San Juan de Dios. A observational job, descriptive, longitudinal, retrospective is pretended to perform, to provide an instrument of guidance to the radiologist about the characteristics of alarm on a breast lesion. Female patients ascribed to the Hospital San Juan de Dios, with breast cancer diagnosed by guided fine needle puncture with echography during the year 2009 are included in the study. Data from 39 patients that fulfilled with all the inclusion criteria were presented. The data obtained were collected by reviewing of clinical records; which were found only women, who in their majority were from the province of San Jose, the most affected age group by the five-year periods has been of 45-49 years, followed by the groups between 40-44 years and 50-54 years. The greater part of cases has treated of unique injuries, almost all have been unilateral and measure the size of all the lesions was 21 mm. The injuries have been primarily in the right breast and the upper outer quadrant. The level of radiological success has been good in cases where was used the BIRADS, because it was classified with 4c or 5 to 52,4% of cases, however, it should be noted that in 17 of 39 cases were not properly categorized BIRADS. The main conclusions of this study are: women whose ages are between 45 and 55 years have been especially prone to mammary neoplasms, these lesions are found primarily in upper outer quadrants and measured more than 2 cm. The health problems generated in the patients with these diagnoses have made important to prioritize your attention once

  4. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  5. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  6. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  7. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  8. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  9. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for thyroid disease using histopathology ... thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity ..... tic accuracy of fine needle aspiration cytology in thyroid.

  10. Thyroid fine-needle aspiration and the bethesda classification system

    DEFF Research Database (Denmark)

    Larsen, Louise Vølund; Egset, Alice Viktoria; Holm, Camilla

    2018-01-01

    INTRODUCTION: Fine-needle aspiration (FNA) is a cornerstone in diagnosing thyroid nodules. For decades, Danish FNA have been categorised into the groups: “FNA not per-formed”, “Inadequate”, “Cystic”, “Inconclusive”, “Benign”, “Suspicious”, “Malignant” and “Information missing”. Internationally...

  11. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    Science.gov (United States)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  12. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  13. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  14. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles.

    Science.gov (United States)

    Shaikh, Jan Muhammad; Memon, Amna; Memon, Muhammad Ali; Khan, Majida

    2008-01-01

    To compare the frequency and severity of post dural puncture headache in obstetric patients using 25G Quincke, 27G Quincke and 27G Whitacre spinal needles. Comparative, randomized, double-blind, interventional study. Liaquat University Hospital Hyderabad from October 2005 to December 2006. 480 ASA I-II full term pregnant women, 18 to 45 years of age, scheduled for elective Caesarean section, under spinal anaesthesia, were randomized into three groups: Group I (25G Quincke spinal needle: n=168), Group II (27G Quincke spinal needle: n=160) and Group III (27G Whitacre spinal needle: n=152). Spinal anaesthesia was performed with 1.5-2.0 ml 0.75% hyperbaric bupivacaine using 25G Quincke spinal needle (Group I), 27G Quincke spinal needle (Group II) and 27G Whitacre spinal needle (Group III) at L3-4 inter-vertebral space. Each patient was assessed daily for four consecutive days following Caesarean section. Frequency and severity and of postdural puncture headache (PDPH) were recorded. Data were analyzed using SPSS-11. Frequency of PDPH following the use of 25G Quincke (Group I), 27G Quincke (Group II) and 27G Whitacre (Group III) spinal needles was 8.3% (14/168), 3.8% (6/160) and 2.0% (3/152) respectively. In Group I, PDPH was mild in 5 patients, moderate in 7 patients and severe in 2 patients. In Group II, it was mild in 2, moderate in 3 and severe in 1 patient. In group III, it was mild in 2 and moderate in 1 patient. Severe PDPH did not occur in Group III. Most of the patients with PDPH developed it on 1st and 2nd postoperative day. When using a 27G Whitacre spinal needle, the frequency and severity of PDPH was significantly lower than when a 25G Quincke or 27G Quincke needle was used.

  15. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  16. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  17. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Directory of Open Access Journals (Sweden)

    Baldini Enke

    2013-02-01

    Full Text Available Abstract Background Measurement of thyroglobulin (Tg protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN metastasis from well-differentiated thyroid cancer (TC. In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp, Tg mRNA (FNAB-Tgm and calcitonin (CT mRNA (FNAB-CTm in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC in 26 CLN, metastatic medullary TC (MTC in 3 CLN, metastatic anaplastic TC (ATC in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters.

  18. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Science.gov (United States)

    2013-01-01

    Background Measurement of thyroglobulin (Tg) protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C) has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN) metastasis from well-differentiated thyroid cancer (TC). In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp), Tg mRNA (FNAB-Tgm) and calcitonin (CT) mRNA (FNAB-CTm) in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC) in 26 CLN, metastatic medullary TC (MTC) in 3 CLN, metastatic anaplastic TC (ATC) in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters. PMID:23421519

  19. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  20. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems

    International Nuclear Information System (INIS)

    Schulz, T.; Roettger, S.; Bahner-Heyne, E.J.; Kluge, G.

    2009-01-01

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  1. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  2. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    Science.gov (United States)

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Sonographic features and ultrasonography-guided fine-needle aspiration of metastases to the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun; Kim, Eun Kyung; Kwak, Jin Young; Moon, Hee Jung; Kim, Ga Ram [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the characteristic ultrasonographic (US) features of metastatic carcinoma to the thyroid, and how accurate US features and ultrasonography-guided fine-needle aspiration (US-FNA) are for the diagnosis of thyroid metastases. Twenty-three thyroid lesions in 23 patients (mean age, 66.7 years; range, 46 to 85 years) that had been diagnosed as thyroid metastases were included. The composition, echogenicity, margin, shape, presence of calcifications, underlying parenchymal echotexture, and vascularity were analyzed in US images of the thyroid metastases. Final US assessments were categorized into probably benign and suspicious malignancy. The presence of suspicious metastatic cervical lymph nodes was noted. The medical records, US-FNA cytology, and pathology reports of these patients were retrospectively reviewed. Of the 23 thyroid lesions, the general US appearance was mass-forming in 21 (91.3%) and non-mass-forming in 2 (8.7%). All 23 lesions showed a solid tumor composition. Common US features among the 21 mass-forming thyroid metastases were hypoechogenicity (81.0%), non-circumscribed margins (90.5%), no calcifications (76.2%), and parallel shape (81.0%). Suspicious cervical lymph nodes were present in 18 patients (78.3%). Of the 23 lesions, 21 (91.3%) were classified as suspicious malignancy, and 2 (8.7%) as probably benign. US-FNA showed diagnostic results specific for metastases in 21 of the 22 patients (95.5%) who had undergone US-FNA. Common US features in thyroid metastasis were hypoechogenicity, non-circumscribed margins, no calcifications, parallel shape, and the presence of suspicious cervical lymph nodes. US-FNA can be effectively used in the diagnosis of thyroid metastasis, preventing unnecessary surgery.

  4. Trans-sphenoidal treatment of postsurgical cerebrospinal fluid fistula: CT-guided closure

    International Nuclear Information System (INIS)

    Floris, R.; Salvatore, C.; Simonetti, G.

    1998-01-01

    Cerebrospinal fluid (CSF) leakage after trans-sphenoidal surgery is a troublesome complication with a risk of meningitis and pneumocephalus. We suggest CT-guided intrasphenoidal injection of fibrin sealant through a 12-gauge needle as a simple alternative to surgical management of CSF fistulae. We treated eight patients, operated via the trans-sphenoidal route (five pituitary adenomas, three craniopharyngiomas), for a postoperative CSF leak by CT-guided intrasphenoidal injection of fibrin sealant alone in three cases and fibrin sealant and autologous blood in 5. CT was obtained 10 days after the procedure in all cases. In four patients, the CSF leak was closed successfully at the first attempt. The procedure was repeated on the four remaining patients because only a reduction in leakage was obtained at the first attempt. This procedure preserves olfaction and avoids the risk of frontal lobe damage. It could therefore represent the treatment of choice in many cases of anterior cranial fossa postsurgical CSF leaks. (orig.) (orig.)

  5. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  6. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  7. CT-guided percutaneous vertebroplasty combined with 125I-seed implantation for metastatic vertebral carcinoma involving the spinal canal: analysis of 23 cases

    International Nuclear Information System (INIS)

    Xie Xiaoxi; Lu Yinxiang; Ji Yong; Wang Xiaowei; Zhang Guodong

    2014-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous vertebroplasty (PVP) combined with 125 I-seed implantation for the treatment of metastatic vertebral carcinoma involving the spinal canal. Methods: A total of 28 involved vertebrae were detected in 23 patients with metastatic vertebral carcinoma. Each patient had 1-2 diseased vertebrae. The lesions included cervical vertebra (n=4), thoracic vertebra (n=13) and lumbar vertebra (n=11). Destroyed posterior vertebral wall was seen in all involved vertebrae. Thirteen vertebrae found in 12 patients showed involvement of the epidural space. According to treatment planning system (TPS) CT-guided implantation of 125 I seeds was carried out first for cervical lesions, which was followed by PVP. For the thoracic and lumbar lesions, unilateral or bilateral puncturing with several particle needles was employed to implant the 125 I seeds, then, PVP with bone cement injection was performed. The complications and the clinical efficacy were analyzed. Results: Successful operation was obtained in all patients. The number of implanted 125 I seeds ranged from 4 to 30 per vertebra, and the volume of injected bone cement was 1-6 ml per vertebra. After the operation the pain relief rate was 86.9% (n=20). The incidence of bone cement leakage was 17.8% (5/28). One patient had radicular pain caused by neuropore leakage, which was relieved after medication. No serious complications, such as spinal cord injury or radiation myelitis, occurred. Conclusion: CT-guided PVP combined with 125 I-seed implantation is effective and safe for the treatment of metastatic vertebral carcinoma involving the spinal canal. This therapy can effectively relieve the pain and control the deterioration of tumor, besides, the incidence of bone cement leakage is very low. (authors)

  8. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  9. RS3PE Syndrome with Iliopsoas Bursitis Distinguished from an Iliopsoas Abscess Using a CT-guided Puncture.

    Science.gov (United States)

    Fukui, Shoichi; Iwamoto, Naoki; Tsuji, Sosuke; Umeda, Masataka; Nishino, Ayako; Nakashima, Yoshikazu; Suzuki, Takahisa; Horai, Yoshiro; Koga, Tomohiro; Kawashiri, Shin-ya; Ichinose, Kunihiro; Hirai, Yasuko; Tamai, Mami; Nakamura, Hideki; Origuchi, Tomoki; Kawakami, Atsushi

    2015-01-01

    A 55-year-old man was diagnosed with remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome. Contrast-enhanced computed tomography for cancer screening showed a mass with low-density centers with an enhanced rim in the left iliopsoas muscle. We suspected an iliopsoas abscess and performed computed-tomography-guided puncture of the mass. Both Gram staining and the culture of the fluid were negative. We diagnosed the patient with RS3PE syndrome with iliopsoas bursitis and administered low-dose corticosteroids without antibiotics. The symptoms, including left hip pain, quickly disappeared following treatment. Clinicians should be aware that iliopsoas bursitis may resemble an iliopsoas abscess. As a result, it is important to make an accurate differential diagnosis.

  10. Iatrogenic intraspinal epidermoid tumor: Myelo-CT and MRI diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Visciani, A.; Balestrini, M.R.; Solero, C.L.; Savoiardo, M.

    1989-07-01

    An 11-year-old boy, treated for acute lymphatic leukemia at the age of 2 with intrathecal injections of Methotrexate, presented with a two year history of pain and signs of lumbo-sacral lesion. MRI, myelography and myelo-CT demonstrated an intradural L4-L5 epidermoid tumor which was removed. Iatrogenic implantation of epithelial cells at the age of two with lumbar punctures is most likely. Decline in incidence of lumbar iatrogenic epidermoid cysts, now an exceedingly rare event, is probably related to improved needles for lumbar punctures. (orig.).

  11. Iatrogenic intraspinal epidermoid tumor: Myelo-CT and MRI diagnosis

    International Nuclear Information System (INIS)

    Visciani, A.; Balestrini, M.R.; Solero, C.L.; Savoiardo, M.

    1989-01-01

    An 11-year-old boy, treated for acute lymphatic leukemia at the age of 2 with intrathecal injections of Methotrexate, presented with a two year history of pain and signs of lumbo-sacral lesion. MRI, myelography and myelo-CT demonstrated an intradural L4-L5 epidermoid tumor which was removed. Iatrogenic implantation of epithelial cells at the age of two with lumbar punctures is most likely. Decline in incidence of lumbar iatrogenic epidermoid cysts, now an exceedingly rare event, is probably related to improved needles for lumbar punctures. (orig.)

  12. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  13. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  14. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  15. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  16. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  17. There is room for improvement in the prevention and treatment of headache after lumbar puncture

    DEFF Research Database (Denmark)

    Stendell, Line; Fomsgaard, Jonna S; Olsen, Karsten S

    2012-01-01

    The incidence of post dural puncture headache (PDPH) after lumbar puncture (LP) can be reduced from 36% to 0-9% by use of an atraumatic needle size 24 gauge (G)/0.56 mm rather than a traumatic needle size 22 G/0.7 mm. The evidence supporting some of the prophylactic and therapeutically treatments...

  18. Unilateral transpedicular percutaneous vertebroplasty using puncture simulation

    International Nuclear Information System (INIS)

    Kobayashi, Ken; Takizawa, Kenji; Koyama, Masamichi; Yoshimatsu, Misako; Sakaino, Shinjiro; Nakajima, Yasuo

    2006-01-01

    The aim of this study was to improve the accuracy of puncture to the median vertebral body using the unilateral transpedicular approach on percutaneous vertebroplasty (PVP). We have developed and evaluated a simple puncture simulation method based on the puncture angle determined by preoperative computed tomography (CT). Two groups were evaluated. The first (group A) comprised 23 patients (34 vertebral bodies) who had undergone PYP without preoperative puncture simulation before May 2004, and the second group (group B) comprised 24 patients (39 vertebral bodies) who had undergone preoperative puncture simulation and PVP after May 2004. CT in the prone position was performed, and the puncture angle on CT (PAC) via the vertebral arch pedicle targeting the anterior one-third median site of the vertebral body was determined. Puncture was performed by targeting the isocenter established on a fluoroscopic monitor based on the PAC. Determinations were made of the success rate (SR) of the median puncture of the vertebral body, the effect of treatment using the visual analogue score, and the overall procedural time between groups A and B. The SR was 56% (19/34 vertebral bodies) in group A, and 97% (37/38 vertebral bodies), including only one vertebral body in which it was difficult to perform the unilateral approach on CT images, in group B, with the difference being significant by Student's t-test (P<0.001). Among patients with available follow-up data, the unipedicular and bipedicular approaches achieved adequate pain relief with mean decreases in pain severity of 5.1±2.6 and 5.9±2.8 respectively. No significant differences in the treatment effect between the two groups was observed (P=0.811). The overall procedure time per puncture was shorten for the simulation group (36.0 min) than for group A (73.1 min), as shown by regression analysis. The preoperative PAC determination for PVP under fluoroscopy increased the completion rate of PVP by the unilateral transpedicular

  19. Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

    Directory of Open Access Journals (Sweden)

    Artner J

    2012-08-01

    Full Text Available Juraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique.Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections.Study design: Comparative study with technical considerations.Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided.Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels.Conclusion: Radiation dose of CT-guided SI joint injections can be

  20. Automatic entry point planning for robotic post-mortem CT-based needle placement.

    Science.gov (United States)

    Ebert, Lars C; Fürst, Martin; Ptacek, Wolfgang; Ruder, Thomas D; Gascho, Dominic; Schweitzer, Wolf; Thali, Michael J; Flach, Patricia M

    2016-09-01

    Post-mortem computed tomography guided placement of co-axial introducer needles allows for the extraction of tissue and liquid samples for histological and toxicological analyses. Automation of this process can increase the accuracy and speed of the needle placement, thereby making it more feasible for routine examinations. To speed up the planning process and increase safety, we developed an algorithm that calculates an optimal entry point and end-effector orientation for a given target point, while taking constraints such as accessibility or bone collisions into account. The algorithm identifies the best entry point for needle trajectories in three steps. First, the source CT data is prepared and bone as well as surface data are extracted and optimized. All vertices of the generated surface polygon are considered to be potential entry points. Second, all surface points are tested for validity within the defined hard constraints (reachability, bone collision as well as collision with other needles) and removed if invalid. All remaining vertices are reachable entry points and are rated with respect to needle insertion angle. Third, the vertex with the highest rating is selected as the final entry point, and the best end-effector rotation is calculated to avoid collisions with the body and already set needles. In most cases, the algorithm is sufficiently fast with approximately 5-6 s per entry point. This is the case if there is no collision between the end-effector and the body. If the end-effector has to be rotated to avoid collision, calculation times can increase up to 24 s due to the inefficient collision detection used here. In conclusion, the algorithm allows for fast and facilitated trajectory planning in forensic imaging.

  1. Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

    International Nuclear Information System (INIS)

    Nakai, Motoki; Sato, Morio; Sahara, Shinya; Takasaka, Isao; Kawai, Nobuyuki; Minamiguchi, Hiroki; Tanihata, Hirohiko; Kimura, Masashi; Takeuchi, Nozomu

    2009-01-01

    Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

  2. Utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration in patients with mediastinal and hilar lymphadenopathy: Western region experience.

    Science.gov (United States)

    Aljohaney, Ahmed A

    2018-01-01

    The aim of the study was to evaluate the clinical utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with mediastinal and hilar lymphadenopathy and to explicitly describe the utility of this procedure in patient's outcome. A retrospective review and analysis was conducted on 52 patients with mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA from June 2012 to June 2016. All the patients were evaluated by computed tomography (CT) chest with contrast before EBUS examination. Enlarged mediastinal or hilar lymph node was defined as >1 cm short axis on the enhanced CT. Among the 52 patients studied, 57.7% were presented with mediastinal or hilar lymphadenopathy for diagnosis and 42.3% presented with suspected mediastinal malignancy. Paratracheal stations were the most common site for puncture in 33 lymph nodes (43%). The best diagnostic yield was obtained from subcarinal stations and the lowest yield from the hilar stations. Surgical biopsies confirmed lymphoma in six patients, tuberculosis (TB) in three, sarcoidosis in two and one had metastatic adenocarcinoma of unknown primary. The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA for diagnosis of mediastinal and hilar lymph node abnormalities were 78.6%, 100%, 100%, and 80%, respectively. The diagnostic yield of EBUS-TBNA in malignant and benign conditions was 79.0%. EBUS-TBNA is a safe and efficacious procedure which can be performed using conscious sedation with high yields. It can be used for the staging of malignancies as well as for the diagnosis of inflammatory and infectious conditions such as sarcoidosis and TB.

  3. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  4. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    DEFF Research Database (Denmark)

    Konge, Lars; Vilmann, P; Clementsen, P

    2012-01-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliabilit...... and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC....

  5. Predictors of Malignancy and Recommended Follow-Up for Patients with Negative Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspected Pancreatic Lesions

    Directory of Open Access Journals (Sweden)

    Bret J Spier

    2009-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA can characterize and diagnose pancreatic lesions as malignant, but cannot definitively rule out the presence of malignancy. Outcome data regarding the length of follow-up in patients with negative or nondiagnostic EUS-FNA of pancreatic lesions are not well-established.

  6. Computer-Aided Design/Computer-Assisted Manufacture-Derived Needle Guide for Injection of Botulinum Toxin into the Lateral Pterygoid Muscle in Patients with Oromandibular Dystonia.

    Science.gov (United States)

    Yoshida, Kazuya

    2018-01-01

    To evaluate the effectiveness and safety of botulinum toxin administration into the inferior head of the lateral pterygoid muscle of patients with jaw opening dystonia by using a computer-aided design/computer-assisted manufacture (CAD/CAM)-derived needle guide. A total of 17 patients with jaw opening dystonia were enrolled. After the patient's computed tomography (CT) scan was imported and fused with a scan of a plaster cast model of the maxilla, the optimal needle insertion site over the lateral pterygoid muscle was determined using the NobelClinician software. A total of 13 patients were injected both with and without the guide, and 4 patients underwent guided injection alone. The therapeutic effects of botulinum toxin injection and its associated complications were statistically compared between the guided and unguided procedures using paired t test. Botulinum toxin therapy was performed 42 and 32 times with and without the guides, respectively. The needle was easily inserted without any complications in all procedures. There was a significant difference (P < .001) between the mean comprehensive improvements observed with (66.3%) and without (54.4%) the guides. The findings suggest that the use of needle guides during the injection of botulinum toxin into the inferior head of the lateral pterygoid muscle is very useful for aiding the accurate and safe administration of botulinum toxin therapy for jaw opening dystonia.

  7. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems; Vergleich zweier Navigationshilfen fuer CT-gesteuerte Interventionen unter besonderer Beruecksichtigung der Nutzungseigenschaften der verwendeten Systeme

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, T. [Inst. fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Jena (Germany); Roettger, S. [Klinik fuer Nuklearmedizin, Medizinische Hochschule Hannover (Germany); Bahner-Heyne, E.J.; Kluge, G. [Inst. fuer Psychologie und Arbeitswissenschaft, FG Arbeits-, Ingenieur- und Organisationspsychologie, TU Berlin (Germany)

    2009-06-15

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  8. Clinical analysis of 44 lung abscess cases

    International Nuclear Information System (INIS)

    Uruga, Hironori; Hanada, Shigeo; Takaya, Hisashi; Miyamoto, Atsushi; Morokawa, Nasa; Kishi, Kazuma

    2012-01-01

    Lung abscess is frequently caused by anaerobes that are difficult to diagnose by sputum examination. To evaluate diagnostic methods and bacteriology of lung abscesses, we retrospectively studied 44 consecutive lung abscess cases (37 men; 7 women; median age, 60 years) admitted and treated at our hospital from 2001 to 2010. The most frequent underlying disease was periodontitis (n=20, 45.5%). The diagnostic rate of causative pathogens by ultrasonography-guided fine-needle aspiration (n=2), computed tomography (CT)-guided fine-needle aspiration (n=19), sputum examination (n=37), and bronchoscopy (n=10) was 100, 68.4, 16.2, and 10%, respectively. In total, 43 causative pathogens were identified in 18 cases (40.9%), of which 12 (67%) had polymicrobial infections. Furthermore, anaerobes and bacterial species belonging to the Streptococcus anginosus group accounted for 55.8 and 14% of the 43 identified pathogens, and both were identified by examination of CT-guided fine-needle aspiration fluid in all cases, except for one patient. Every case was successfully treated with antibiotics. Anaerobes and species of the S. anginosus group are common causes of lung abscess, and CT-guided fine-needle aspiration is a useful diagnostic tool for identifying these causative agents. (author)

  9. Sacral-neuromodulation CT-guided

    International Nuclear Information System (INIS)

    Amoroso, Lamberto; Ricci, Stefano; Pelliccioni, Giuseppe; Scarpino, Osvaldo; Ghiselli, Roberto; Saba, Vittorio

    2005-01-01

    Purpose: Sacral neuromodulation is a new treatment for refractory voiding disorders such as urge incontinence, urinary retention, frequency-urgency syndromes and faecal incontinence. The current approach to sacral nerve stimulation consists of a two-stage procedure. The first is a PNE test (Percutaneous Nerve Evaluation) by a provisional electrically stimulated spinal needle, placed percutaneously in the S3 foramina for four of ten days. If successful, the second stage, permanent implantation, is carried out. The PNE test is performed under fluoroscopic control using the palpable bony sacral foramina as referral points. This technique can show some limitations, such as operator Rx exposure, poor visualization of sacral foramina because of bowel gas artefacts or sacral malformation. In order to reduce these inconveniences and to improve efficiency of the test we tried an alternative technique. The purpose of our study was to test the use of CT as an alternative technique in order to evaluate its advantages and possible routine use. Materials and methods: We tested 30 patients with the PNE test under CT guidance (16 males and 14 females) suffering from serious pelvic disorders and not responding to the normal therapeutic regime. Twenty-seven patient showed relative anatomical integrity of the pelvis and the sacrum, the remaining 3 patients presented morphological anormalities of the sacral foramina. With the patient in the prone position the sacral foramina were identified with CT volumetric scanning using a spiral CT scanner equipped with a second console for the three-dimensional reconstructions. Having identified the location of the S3 foramina, a sterile field was prepared and the spiral needle introduced checking correct positioning with a CT control scan. An electrode was inserted after having checked correct muscular contractile response and the precise position with a further CT scan. Results: Thirty patients were subjected to PNE under CT guidance for a

  10. Cerebellar and brainstem infarction as a complication of CT-guided transforaminal cervical nerve root block

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, S. [The Royal National Orthopaedic Hospital NHS Trust, London (United Kingdom); Berman, J. [The Royal National Orthopaedic Hospital NHS Trust, Anaesthetic Department, London (United Kingdom); Connell, David A. [The Royal National Orthopaedic Hospital NHS Trust, Department of Radiology, London (United Kingdom)

    2007-05-15

    A 60-year-old man with a 4-year history of intractable neck pain and radicular pain in the C5 nerve root distribution presented to our department for a CT-guided transforaminal left C5 nerve root block. He had had a similar procedure on the right 2 months previously, and had significant improvement of his symptoms with considerable pain relief. On this occasion he was again accepted for the procedure after the risks and potential complications had been explained. Under CT guidance, a 25G spinal needle was introduced and after confirmation of the position of the needle, steroid was injected. Immediately the patient became unresponsive, and later developed a MR-proven infarct affecting the left vertebral artery (VA) territory. This is the first report of a major complication of a cervical root injection under CT guidance reported in the literature. We present this case report and the literature review of the potential complications of this procedure. (orig.)

  11. Cerebellar and brainstem infarction as a complication of CT-guided transforaminal cervical nerve root block

    International Nuclear Information System (INIS)

    Suresh, S.; Berman, J.; Connell, David A.

    2007-01-01

    A 60-year-old man with a 4-year history of intractable neck pain and radicular pain in the C5 nerve root distribution presented to our department for a CT-guided transforaminal left C5 nerve root block. He had had a similar procedure on the right 2 months previously, and had significant improvement of his symptoms with considerable pain relief. On this occasion he was again accepted for the procedure after the risks and potential complications had been explained. Under CT guidance, a 25G spinal needle was introduced and after confirmation of the position of the needle, steroid was injected. Immediately the patient became unresponsive, and later developed a MR-proven infarct affecting the left vertebral artery (VA) territory. This is the first report of a major complication of a cervical root injection under CT guidance reported in the literature. We present this case report and the literature review of the potential complications of this procedure. (orig.)

  12. a pilot study of the diagnostic accuracy of fine needle aspirate cytol

    African Journals Online (AJOL)

    2018-06-02

    Jun 2, 2018 ... Fibroadenoma of the breast in a South African population -a pilot study of the ... Keywords: Fibroadenoma, diagnosis, breast ultrasonography, fine needle ..... breast cancer among Sudanese patients with breast palpa-.

  13. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  14. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  15. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com; Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp; Suzuki, Michiko, E-mail: mamimichiko@me.com [Iwate Medical University School of Medicine, Department of Radiology (Japan); Sone, Miyuki, E-mail: msone@me.com [National Cancer Center Hospital, Department of Diagnostic Radiology (Japan); Tanaka, Ryoichi, E-mail: rtanaka@iwate-med.ac.jp; Nakasato, Tatsuhiko, E-mail: nakasato@iwate-med.ac.jp; Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Iwate Medical University School of Medicine, Department of Radiology (Japan)

    2016-02-15

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

  16. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    International Nuclear Information System (INIS)

    Tamura, Akio; Kato, Kenichi; Suzuki, Michiko; Sone, Miyuki; Tanaka, Ryoichi; Nakasato, Tatsuhiko; Ehara, Shigeru

    2016-01-01

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC

  17. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  18. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo (Egypt); Alsubhi, Mohammed [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N. [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Alexandria University Hospital, Alexandria (Egypt); Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-10-15

    's depth from the pleural surface (p = 0.021 and 0.018 in non-coaxial and coaxial groups respectively), increased distance of traversed lung in the needle track of more than 2.5 cm (p = 0.001 in both groups). Insignificant risk factors were patient's age, gender or emphysema in both groups (p value >0.1 in both groups). Concomitant incidence of pneumothorax was 32.3% (21/65) in non-coaxial group and 36.6% (26/71) in coaxial group. Pulmonary hemorrhage in the majority of cases was treated conservatively. Conclusion: Pulmonary hemorrhage complicating CT-guided core biopsy of pulmonary lesions, showed insignificant difference between coaxial and non-coaxial techniques. Significant risk factors of pulmonary hemorrhage included small and basal lesions, increased lesion's depth from pleural surface, increased length of aerated lung parenchyma crossed by biopsy needle and passing through vessels within the lung during puncture.

  19. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    International Nuclear Information System (INIS)

    Nour-Eldin, Nour-Eldin A.; Alsubhi, Mohammed; Naguib, Nagy N.; Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    's depth from the pleural surface (p = 0.021 and 0.018 in non-coaxial and coaxial groups respectively), increased distance of traversed lung in the needle track of more than 2.5 cm (p = 0.001 in both groups). Insignificant risk factors were patient's age, gender or emphysema in both groups (p value >0.1 in both groups). Concomitant incidence of pneumothorax was 32.3% (21/65) in non-coaxial group and 36.6% (26/71) in coaxial group. Pulmonary hemorrhage in the majority of cases was treated conservatively. Conclusion: Pulmonary hemorrhage complicating CT-guided core biopsy of pulmonary lesions, showed insignificant difference between coaxial and non-coaxial techniques. Significant risk factors of pulmonary hemorrhage included small and basal lesions, increased lesion's depth from pleural surface, increased length of aerated lung parenchyma crossed by biopsy needle and passing through vessels within the lung during puncture

  20. Diagnosis of disseminated candidiasis by fine needle aspiration of lymph node and by splenic imprint in a patient with acute promyelocytic leukemia.

    Science.gov (United States)

    Chao, T Y; Chang, J Y; Yu, C Y; Tsao, T Y

    1995-01-01

    Cytologic studies were done on fine needle aspirates of the lymph node and imprints of splenic biopsies from a patient with acute promyelocytic leukemia who was febrile while being treated with chemotherapy. Examination of the lymph node aspirates revealed pus and numerous pseudohyphae which were later identified as Candida tropicalis. When multiple nodular lesions were detected in the spleen by abdominal sonography and CT scan, needle biopsy of the spleen was done. Cytologic examination of touch imprints of the biopsy disclosed intracellular fungal blastospores. The patient was treated with and responded well to amphotericin B and 5-fluorocytosine. As a result of our experience with this patient we emphasize the importance of close incorporation of clinical information and diagnostic cytology. With such a cooperation, cytologic studies become a most useful method for diagnosis.

  1. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  2. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    Science.gov (United States)

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  3. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    Science.gov (United States)

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  4. A cutting biopsy needle for the histological diagnosis of abdominal and retroperitoneal masses

    International Nuclear Information System (INIS)

    Hauenstein, K.H.; Wimmer, B.; Freudenberg, N.; Freiburg Univ.

    1985-01-01

    A new cutting biopsy needle has been used to obtain histologically useful material while causing the minimum of trauma. It permits biopsies of organs, but its small external diameter of 0.8 or 0.95 mm makes it possible to carry out transperitoneal puncture of the stomach, colon or liver and of the retroperitoneal space, using a ventral approach. Tissue samples were obtained in 96% of 63 patients. The risk of complications is no higher than for conventional needles used for cytology. The accuracy with which the material can be obtained is therefore the most important problem. The position of the area to be biopsied should determine whether the biopsy is to be aided by sonography or CT. Biopsies of organs can be appropriately carried out under ultrasound control, but processes in the pelvis and in retroperitoneal-paravertebral and extra-peritoneal positions are best biopsied under CT control. (orig.) [de

  5. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  6. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shangang, E-mail: 1198685580@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Li, Chengli, E-mail: chenglilichina@yeah.net [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Yu, Xuejuan, E-mail: yuxuejuan2011@126.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Liu, Ming, E-mail: mingliuyxs@163.com [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Fan, Tingyong, E-mail: FTY681105@sohu.com; Chen, Dong, E-mail: 857984870@qq.com; Zhang, Pinliang, E-mail: zhangpinliang@163.com; Ren, Ruimei, E-mail: liusg708@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China)

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

  7. Use of a vegetable model as a training tool for PCNL puncture.

    Science.gov (United States)

    Sinha, Maneesh; Krishnamoorthy, Venkatesh

    2015-01-01

    Training residents to perform a PCNL puncture is hampered by the non-availability of a good inanimate model that can be used for demonstration and practice. The ethics of surgical training during actual surgeries is being questioned and the role of simulation is increasingly important. Virtual reality trainers, however, are prohibitively expensive and the use of animal models is fraught with regulatory and ethical concerns. We have devised a model that can be used to teach the concept of depth perception during a PCNL puncture. A bottle gourd was used to mimic the posterior abdominal wall. Cotton pledgets dipped in intravenous contrast were fitted into 4 mm holes made at staggered levels in the bottle gourd which was strapped onto the operating table with the cotton pledgets facing away from the surgeon. Surgeons with varying degrees of experience made fluoroscopy-guided punctures onto the cotton pledgets. We recorded the time taken for puncture in seconds and the distance of the needle exit site from the center of the cotton ball. Speed was measured by recording the fluoroscopy time in seconds on the C-arm. Accuracy was documented by using a Vernier caliper to measure the distance from the edge of the target to the actual puncture. One second of fluoroscopy time and 0.1 mm distance were each given one point. The total points accumulated over a set of 10 punctures was added to give a total score. Longer fluoroscopy times and inaccurate punctures resulted in higher scores. A surgeon with more than 1000 PCNLs to his credit had a score of 99. The average score of five residents was 555. The bottle gourd model provides an ethically acceptable, inexpensive, easy to replicate model that can be used to train residents in the PCNL puncture.

  8. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  9. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  10. Endoscopic ultrasound-guided fine-needle aspiration diagnosis of secondary tumors involving the pancreas: An institution′s experience

    Directory of Open Access Journals (Sweden)

    Ahmed K Alomari

    2016-01-01

    Full Text Available Background: Pancreatic masses may seldom represent a metastasis or secondary involvement by lymphoproliferative disorders. Recognition of this uncommon occurrence may help render an accurate diagnosis and avoid diagnostic pitfalls during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA. In this study, we review our experience in diagnosing secondary tumors involving the pancreas. Materials and Methods: The electronic database of cytopathology archives was searched for cases of secondary tumors involving the pancreas at our institution and a total of 31 cases were identified. The corresponding clinical presentations, imaging study findings, cytological diagnoses, the results of ancillary studies, and surgical follow-up, if available, were reviewed. Results: Nineteen of the patients were male and 12 female, with a mean age of 66 years. Twenty-three patients (74% had a prior history of malignancy, with the latency ranging from 6 months to 19 years. The secondary tumors involving the pancreas included metastatic carcinoma (24 cases, metastatic sarcoma (3 cases, diffuse large B-cell lymphoma (2 cases, and plasma cell neoplasm (2 cases. The most common metastatic tumors were renal cell carcinoma (8 cases and lung carcinoma (7 cases. Correct diagnoses were rendered in 29 cases (94%. The remaining two cases were misclassified as primary pancreatic carcinoma. In both cases, the patients had no known history of malignancy, and no ancillary studies were performed. Conclusions: Secondary tumors involving the pancreas can be accurately diagnosed by EUS-FNA. Recognizing uncommon cytomorphologic features, knowing prior history of malignancy, and performing ancillary studies are the keys to improve diagnostic performance and avoid diagnostic pitfalls.

  11. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  12. Fine needle aspiration cytology: sensitivity and specificity in thyroid lesions

    International Nuclear Information System (INIS)

    Musani, M.A.; Khan, F.A.; Malik, S.; Khambaty, Y.

    2011-01-01

    Background: Thyroid enlargement is one of the common problems in patients presenting at outpatients department of ENT particularly in females. Thyroid nodules are common, thyroid cancer is uncommon and the most common way for it to present is as a solitary thyroid nodule. This study was conducted to evaluate the sensitivity and specificity of Fine Needle Aspiration Cytology (FNAC) in thyroid diseases. Method: This prospective analytic study was conducted at ENT Department of Karachi Medical and Dental College/Abbasi Shaheed Hospital during year 2004-8. One hundred and five cases were enrolled who underwent thyroid surgery after complete evaluation by history, clinical examination, Thyroid profile, Thyroid Scintigraphy, Ultrasound neck and FNAC. In cases which were revealed malignant by FNAC, CT scan were done to see the extent of disease and neck node status. Surgery was done in all cases and specimens sent for histopathology. Results: Male to female ratio of the patients was 1:8.5. Most common lesion was benign nodule (96). Malignant lesions were 9 in FNAC. In histopathology, the benign nodules were 92, and malignant cases were 13. Sensitivity of FNAC was 61.53% and specificity was 98.9%. Conclusion: FNAC in Thyroid has high sensitivity and specificity. (author)

  13. Ultrasound-Guided Fine Needle Aspiration Cytology in the Assessment of Cervical Metastasis in Patients Undergoing Elective Neck Dissection

    International Nuclear Information System (INIS)

    Dabirmoghaddam, Payman; Sharifkashany, Shervin; Mashali, Leila

    2014-01-01

    In head and neck cancer patients, diagnosis of metastatic cervical adenopathy is essential for treatment planning and prognosis assessment. Treatment of patients with head and neck cancer with clinically negative cervical lymph node (N0) remains controversial. While routine neck treatment would result in overtreatment in many patients, observation may delay the diagnosis and decrease the patients’ survival. To gain insights into the unclear questions regarding the value of diagnostic modalities in patients with N0 neck, this study was designed to compare the diagnostic efficacy of palpation, ultrasonography (US) and ultrasound-guided fine needle aspiration (USGFNA) in detecting cervical lymph node metastasis. Forty-two patients with head and neck cancer who underwent US and USGFNA prior to elective neck dissection were studied. Histopathologic findings of the neck specimens were compared with each diagnostic technique. Of the 53 neck dissection specimens, histopathology showed metastases in 16 cases. The overall accuracy of USGFNA, US and palpation was 96%, 68% and 70%, respectively. The specificity of USGFNA was superior to palpation and US alone. USGFNA had the highest sensitivity, predictive value and accuracy in detecting cervical metastases compared with other performed tests. In our study, USGFNA was superior to palpation and US in detecting metastasis in clinically negative necks. This method can be recommended as a diagnostic tool in preoperative assessment of patients without palpable metastasis, but further investigations are needed before this modality could be considered as an alternative to elective neck dissection

  14. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    formation of ice ball and the process of lesion ablation, etc. However, MR scan was tim.e consuming, and image quality of low-field open MR was less desirable than that of CT. The 12-month overall survival rates were 90.2% (55/61) and 90.0% (54/60), respectively. The overall efficacies of lesion ablation were 75.4% (46/61) and 83.4% (50/60), respectively. Conclusion: CT has advantages of fast scanning and good display of such structures as ribs in the path of puncture as compared with MR. MR can display a lesion with multi-planar imaging, and is superior to CT in monitoring the procedure of ablation, especially in displaying, guiding and monitoring ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. (authors)

  15. Stereotaxic Fine-Needle Aspiration Cytologic Evaluation of Non-palpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    M Haghighi

    2005-07-01

    Full Text Available Background: Although long-term mammography is the standard means of evaluation for the probably benign lesions of breast, some times we feel obliged to know about the benignity and the extent of lesions earlier. Therefore we evaluated the diagnostic value of stereotaxic fine-needle aspiration (SFNA in low suspicion breast lesions as an alternative to the routine modality. Methods: The study included 150 low-suspicion or probably benign breast lesions detected on mammography. All cases underwent SFNA and followed by exciosional biopsy or follow-up mammography based on SFNA findings. Results: Fibroadenoma and normal tissue lesions were diagnosed in 57% of patients, in whom no evidence of malignancy was found in the follow-up period. In 48 patients with cytologic findings suggestive of proliferative fibrocystic disease, three cases of malignancy were detected by excisional biopsy. Conclusion: A SFNA result suggesting benignity allows safe clinical follow-up, whereas a suspicious or equivocal diagnosis needs more invasive modalities for further investigations. Key words: Breast, Mammography, Stereotaxic, Fine-Needle Aspiration (FNA

  16. CT thermometry for cone-beam CT guided ablation

    Science.gov (United States)

    DeStefano, Zachary; Abi-Jaoudeh, Nadine; Li, Ming; Wood, Bradford J.; Summers, Ronald M.; Yao, Jianhua

    2016-03-01

    Monitoring temperature during a cone-beam CT (CBCT) guided ablation procedure is important for prevention of over-treatment and under-treatment. In order to accomplish ideal temperature monitoring, a thermometry map must be generated. Previously, this was attempted using CBCT scans of a pig shoulder undergoing ablation.1 We are extending this work by using CBCT scans of real patients and incorporating more processing steps. We register the scans before comparing them due to the movement and deformation of organs. We then automatically locate the needle tip and the ablation zone. We employ a robust change metric due to image noise and artifacts. This change metric takes windows around each pixel and uses an equation inspired by Time Delay Analysis to calculate the error between windows with the assumption that there is an ideal spatial offset. Once the change map is generated, we correlate change data with measured temperature data at the key points in the region. This allows us to transform our change map into a thermal map. This thermal map is then able to provide an estimate as to the size and temperature of the ablation zone. We evaluated our procedure on a data set of 12 patients who had a total of 24 ablation procedures performed. We were able to generate reasonable thermal maps with varying degrees of accuracy. The average error ranged from 2.7 to 16.2 degrees Celsius. In addition to providing estimates of the size of the ablation zone for surgical guidance, 3D visualizations of the ablation zone and needle are also produced.

  17. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  18. Guide for the realization of core needle biopsy through stereotaxy in the diagnosis of suspicious breast lesions of malignity

    International Nuclear Information System (INIS)

    Jimenez Zuniga, Jorge Luis

    2012-01-01

    demonstrated to be more precise and to make more accurate the diagnostic evaluation. While, the systems of vacuum-assisted biopsy have allowed the obtention of higher quality cylinders, clearly improving results, especially in cases of microcalcifications. The main indications for the use of stereotaxy in the intervention of the breast are analyzed, among which can be mentioned: fine-needle aspiration biopsy, core needle biopsy and preoperative localization. The technique of fine-needle aspiration biopsy has gained acceptation in the diagnosis of palpable lesions of the breast, the function of this technique in the management of nonpalpable lesions not is completely defined, due to the high percentage of insufficient samples. The systems of core needle biopsy have allowed the obtention of multiple cylinders with great diagnostic reliability, especially in the case of breast nodules. However, its use in microcalcifications has showed false negative results. The preoperative localization through needle in the nonpalpable lesions of the breast, has allowed to the radiologist to provide a guide to the surgeon that has realized the open biopsy, ensuring thus, that surgical procedure can be carried out quickly and with the best possible cosmetic result. The radiological assessment of the breast lesions in mammography are defined, in order to standardize the terminology applied at the time to report studies of the breast, to categorize the lesions according to the level of suspicion and to assign a recommendation to follow in injury determined. Before all nonpalpable breast lesion that has required a biopsy, should be considered first which will be the guidance system most adequate, and second, which is the technique with best diagnostic performing and better relationship cost/effectiveness. The core needle biopsy (CNB) has been a little aggressive technique and highly reliable in the diagnosis of the palpable and nonpalpable lesions. The sensitivity of the CNB has been different

  19. Muscle metastases: ultrasound and CT scan imaging in nine cases. Report on 9 cases

    International Nuclear Information System (INIS)

    Folinais, D.; Cluzel, Ph.; Blangy, S.; Sibert, A.; David, M.; Benacerraf, R.

    1988-01-01

    Clinical, ultrasound and CT scan examinations were carried out in 9 patients with secondary muscle lesions. All muscles can be affected but there was a marked predominance of psoas lesions (6 of the 9 cases). Two contrasting clinical pictures are seen. Secondary muscle tumors can occur during evolution of a known treated cancer (5 of the 9 cases), revealed usually by large, rarely painful, mass. CT scan imaging shows an heterogeneous mass taking up contrast and often partially necrotic, the lesions appearing hypoechogenic or heterogeneous on ultrasound exmination. Certain lesions can be totally necrotic. In some cases (4 of the 9 patients) the muscle metastases revealed the presence of a tumor. Symptomatology may be atypical and lead to a delay in diagnosis. Fine needle puncture biopsy can detect the secondary origin of the muscle lesion and also the primary tumor site (4 out of 9 cases), bronchopulmonary and colon cancer predominating. Images are however non-specific and in the absence of NMR imaging the muscle or lymph node metastases can be confused, although this has no practic consequences since treatment is identical [fr

  20. Selective fine needle aspiration of parotid masses. FNA should be performed in all patients older than 60 years.

    LENUS (Irish Health Repository)

    Kieran, S M

    2012-02-01

    OBJECTIVES: The exact role of fine needle aspiration in the pre-operative assessment of patients presenting with parotid masses is controversial. Some surgeons propose that fine needle aspiration be performed only selectively in those patients with likely malignant disease, whilst others recommend it for all patients presenting with such a mass. Intuitively, one would expect older patients to be more likely to suffer from primary malignant parotid tumours and secondary deposits of malignant skin tumours. Therefore, we hypothesised that older patients with a parotid mass should undergo fine needle aspiration regardless of their medical history. DESIGN: We retrospectively reviewed 197 consecutive parotidectomies to test this hypothesis. RESULTS: One hundred and twenty-one patients (61.4 per cent) were diagnosed with benign disease, whilst 76 (38.6 per cent) were diagnosed with malignant disease. Eighty-three per cent of patients aged 60 years or younger had benign disease, as opposed to 35.6 per cent of patients aged more than 60 years. Malignant disease occurred more commonly in patients older than 60 years (odds ratio 8.962, 95 per cent confidence interval 4.607-17.434). CONCLUSION: In patients with a parotid mass, fine needle aspiration should be performed on all those aged 60 years or older.

  1. Evaluation of a mammographic stereotactic device for localization, fine-needle aspiration cytologic studies, and core biopsy of suspicious lesions

    International Nuclear Information System (INIS)

    Fajardo, L.J.; Davey, G.A.

    1988-01-01

    Mammography-guided interventional breast procedures, such as preoperative localization, fine-needle aspiration cytology (FNAC), and core biopsy of suspicious lesions, require accurate three-dimensional localization. The authors have evaluated a prototype stereotactic mammography device for localizing abnormalities with both phantom and clinical studies. Twenty-six localizations on a phantom were within 0.5 mm +- 0.93 (standard deviation) from the lesions; accuracy in clinical procedures was within 0.6 mm +- 0.8. Procedures are performed an average of 8 minutes faster with this device. They are prospectively evaluating mammography-guided FNAC and core biopsy of suspicious lesions in 100 patients. Results of FNAC performed without the stereotactic device agreed with results of open surgical biopsy in six of eight patients; results of core biopsy agreed in seven of eight

  2. Diagnostic accuracy of fine needle aspiration cytology in hepatic tumours

    International Nuclear Information System (INIS)

    Nazir, R.T.; Sharif, M.A.; Iqbal, M.; Amin, M.S.

    2010-01-01

    To determine the diagnostic accuracy of fine-needle aspiration cytology (FNAC) in liver masses to isolate malignant from benign tumours and hepatocellular carcinoma (HCC) from metastatic tumours. Study Design: Cross-sectional, observational. Place and Duration of Study: Department of Histopathology, Combined Military Hospital, Peshawar, from June 2004 to June 2005. Methodology: All the patients with liver masses confirmed by ultrasonography, irrespective of age and gender, were included. Patients with inflammatory lesions were excluded from the study. Selected patients underwent fine-needle aspiration under ultrasound guidance followed by needle biopsy. The cytological slides were stained by haematoxylin and eosin (H and E) stain, while Papanicolaou's stain was employed in selective cases. Needle biopsy fragments were fixed in formalin followed by paraffin embedding and staining with H and E stain. Sensitivity and specificity of FNAC in the diagnosis of liver masses was determined using histological diagnosis on liver biopsy as gold standard. Results: There were one hundred subjects. The mean age at presentation was 55 +- 12 years with male to female ratio of 1.7:1. Cytological diagnosis in 19 cases was benign/non-neoplastic and 81 was malignant. Out of the latter, 49 (60.49%) were HCC and 32 (39.51%) were metastatic tumours on cytology. The overall sensitivity, specificity and accuracy of FNAC in the diagnosis of malignant lesions was 95.2%, 100% and 96% respectively using histological diagnosis on liver biopsy as gold standard. Sensitivity of FNAC to differentiate HCC from metastatic tumours in liver was 96% while specificity was 100% having a diagnostic accuracy of 97.5%. The discrepancy in cyto-histological comparison was mainly seen in well differentiated and poorly-differentiated HCCs. Conclusion: FNAC of the liver masses is a simple, safe, accurate, economical screening test without significant morbidity that can be used to identify the vast majority of

  3. Protective pneumothorax in CT monitored mediastinal puncture

    International Nuclear Information System (INIS)

    Wein, B.B.; Dickgreber, N.J.; Guenther, R.W.

    1997-01-01

    Purpose: To achieve an extrapulmonary pathway for biopsy of mediastinal masses. Methods: In 6 patients a protective, temporary pneumothorax was established before performing large-bore needle biopsies of mediastinal masses using a Verres-needle. Results: Transpleural, extrapulmonary access was easy to achieve. One patient developed a tension pneumothorax after biopsy which was drained by percutaneous small chest tube. Another patient showed mediastinal tumour bleeding through the biopsy needle. As a prophylactic measure the bleeding was stopped by injection of tissue glue through the biopsy needle. Conclusion: The use of protective pneumothorax allows cutting needle biopsies of mediastinal masses where aspiration cytology yields no secure specific diagnosis. (orig.) [de

  4. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  5. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  6. Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates

    International Nuclear Information System (INIS)

    Connor, S.; Dyer, J.; Guest, P.

    2000-01-01

    We reviewed the diagnostic accuracy and complication rates of transthoracic needle biopsy (TNB) with an automated 18-gauge core biopsy needle and gun, using either fluoroscopic or CT guidance. One hundred six lesions were biopsied in 103 patients between 1992 and 1998. Hard-copy images, imaging reports, pathology reports and clinical notes were reviewed. In 3 patients it was not possible to establish the lesion as either malignant or benign from the available follow-up, so these were removed from the analysis of diagnostic accuracy. Adequate samples for histological diagnosis were obtained in 104 of 106 (98 %) biopsies. There were 75 of 85 (88 %) true-positive core biopsies for malignant lesions and a specific cell type was identified in 70 of 85 (82 %) cases. A specific histological diagnosis was obtained in 12 of 18 (66 %) biopsies. There was a 19 % rate of pneumothorax with only 2.4 % requiring drainage. Minor haemoptysis occurred in 3.8 % of procedures. The TNB technique with an automated core biopsy needle provides a high level of diagnostic accuracy, effectively distinguishes cell type in malignancy and provides a definite diagnosis in benign disease more frequently than fine needle aspiration (FNA). There is no increased complication rate compared with FNA. (orig.)

  7. Microneedle arrays allow lower microbial penetration than hypodermic needles in vitro.

    Science.gov (United States)

    Donnelly, Ryan F; Singh, Thakur Raghu Raj; Tunney, Michael M; Morrow, Desmond I J; McCarron, Paul A; O'Mahony, Conor; Woolfson, A David

    2009-11-01

    In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. When employing Silescol membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol membranes in the corresponding experiments. Approximately 10(3) cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle-punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e

  8. Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.

    Science.gov (United States)

    Greenstein, Eugene; Passman, Rod; Lin, Albert C; Knight, Bradley P

    2012-04-01

    The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (Pelectrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).

  9. Safety and correlation of test results of combined ultrasound-guided fine-needle aspiration and needle core biopsy of the canine spleen.

    Science.gov (United States)

    Watson, Adam T; Penninck, Dominique; Knoll, Joyce S; Keating, John H; Sutherland-Smith, James

    2011-01-01

    The safety and diagnostic value of combined splenic fine-needle aspiration (FNA) and needle core biopsy (NCB) is unknown. Forty-one dogs with splenic lesions were studied prospectively. Safety was assessed in 38 dogs and no complications were encountered. Initially, clinical and anatomic pathologists reviewed each FNA and NCB sample, respectively, without knowledge of the other's results. Diagnoses were categorized as neoplastic, benign, inflammatory, normal, or nondiagnostic. The level of agreement between sampling methods was categorized as complete, partial, disagreement, or not available. Test correlation was performed in 40 dogs. Nondiagnostic results occurred in 5/40 NCB (12.5%) and no FNA samples. Neoplasia was diagnosed in 17/40 dogs (42.5%), benign changes in 20/40 dogs (50%), inflammatory disorders in 0/40 dogs, and normal 2/40 dogs (5%). One of the 40 dogs (2.5%) had a diagnosis that was equivocal for neoplasia on both tests and therefore was not categorized. Of the 35 dogs that had diagnostic samples, cytopathologic and histopathologic diagnoses agreed completely in 18/35 dogs (51.4%), partially in 3/35 dogs (8.6%), and were in disagreement in 14/35 dogs (40.0%). Pathologists collaboratively reviewed diagnoses that were in disagreement or partial agreement and altered their individual diagnoses in 6/17 dogs (35.3%) to be within partial or complete agreement, respectively. Percutaneous FNA and NCB can be performed safely in dogs with sonographic splenic changes. Results suggest that adding NCB to FNA provides complementary information in dogs with suspected splenic neoplasia. This combined protocol may improve detection of splenic neoplasia and provide neoplastic subclassification. © 2010 Veterinary Radiology & Ultrasound.

  10. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape

    DEFF Research Database (Denmark)

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie

    2009-01-01

    BACKGROUND: Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metasta...

  11. Mechanics of anesthetic needle penetration into human sciatic nerve.

    Science.gov (United States)

    Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A

    2018-06-06

    Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  13. Pancreatic metastasis in a case of small cell lung carcinoma: Diagnostic role of fine-needle aspiration cytology and immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Dilip K Das

    2011-01-01

    Full Text Available Small cell lung carcinoma represents a group of highly malignant tumors giving rise to early and widespread metastasis at the time of diagnosis. However, the pancreas is a relatively infrequent site of metastasis by this neoplasm, and there are only occasional reports on its fine needle aspiration (FNA cytology diagnosis. A 66-year-old man presented with extensive mediastinal lymphadenopathy and a mass in the pancreatic tail. Ultrasound-guided FNA smears from the pancreatic mass contained small, round tumor cells with extensive nuclear molding. The cytodiagnosis was metastatic small cell carcinoma. Immunocytochemical staining showed that a variable number of neoplastic cell were positive for cytokeratin, chromogranin A, neurone-specific enolase and synaptophysin but negative for leukocyte common antigen. The trans-bronchial needle aspiration was non-diagnostic, but biopsy was suspicious of a small cell carcinoma. This case represents a rare metastatic lesion in the pancreas from small cell lung carcinoma, diagnosed by FNA cytology.

  14. Pneumatocek therapy with Chiba needle desuflation by CT control

    International Nuclear Information System (INIS)

    Mach, P.; Zachar, M.

    1996-01-01

    The authors demonstrated 18 month old girl with pneumatocele. In girl on accout of the persistence of of pneumatocele for more than eight an half month, regard to the localisation desuflation with Chiba needle under CT control was performed. After this procedure pneumatocele deminished in size and complete recovery occurred after for and half month. (authors). 5 figs., 8 refs

  15. Cytological and sonographic correlation of the biopsies by fine needle aspiration (FNAB) of thyroid nodules in the Hospital San Rafael de Alajuela of July 1, 2006 to February 28, 2007

    International Nuclear Information System (INIS)

    Barrantes Vega, Jesus

    2007-01-01

    The importance of the use of aspiration biopsy with ultrasonic-guided fine needle is recognized as screening method for diagnosis of thyroid nodules. Thyroid nodules are very common, the prevalence of palpitation has been estimated by 4% and 6% by ultrasound. The prevalence in autopsy data of patients with no history of thyroid pathology has been up to 50%. The use set of advanced imaging techniques and modified techniques of biopsy is implemented in order to increase the diagnostic security of thyroid lesions. The incidental finding of thyroid nodules or incidentalomas has soared dizzily, since the advent of ultrasound as an element in the valuation of thyroid disease and thyroid in the neck. Incidence has been reported even up to 40%. A growing number of endocrinologists are using aspiration biopsy with ultrasound guided fine needle of thyroid nodules as initial diagnostic procedure to identify discrete nodules with a direct location. The percentage of malignant nodules or that require surgery by size or symptomatology, generally, is very low, had to be established a systematic approach to reducing morbidity and mortality associated with major surgery of the neck and reduce costs. The biopsy by fine needle aspiration has been a well established diagnostic technique for preoperative evaluation of thyroid nodules, which has led a significant reduction in the number of unnecessary surgeries in most centers has been between 35-75%. This biopsy has been a specific method, sensitive and inexpensive. The sonographic guidance for biopsy by fine needle aspiration offers the following benefits: is safe and inexpensive, able to reduce costs in 25%, minimally invasive and highly effective, this guidance has increased the detection of malignancy of 14 to 39%. Among the complications that can occur is the formation of hematoma and pain, which are rare. On the other hand, the sonographic guidance is essential for biopsy nonpalpable nodules helping to ensure proper placement of

  16. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  17. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  18. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  19. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  20. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  1. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan [Goethe University Hospital, Institute for Diagnostic and Interventional Radiology, Frankfurt (Germany); Czerny, Christoph [Goethe University Hospital, Department of Trauma Surgery, Frankfurt (Germany)

    2013-01-15

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  2. Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study

    International Nuclear Information System (INIS)

    Schulz, Boris; Eichler, Katrin; Siebenhandl, Petra; Gruber-Rouh, Tatjana; Vogl, Thomas Josef; Zangos, Stephan; Czerny, Christoph

    2013-01-01

    To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle guidance software. A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluoroscopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (n = 20 each). Target distance, needle deviation and time for the procedures were analysed. All phantom interventions (n = 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min). When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories. (orig.)

  3. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety

    Directory of Open Access Journals (Sweden)

    Fujii C

    2013-07-01

    Full Text Available Chieko FujiiFaculty of Nursing and Medical Care, Keio University, Kanagawa, JapanBackground: Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures.Methods: Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined.Results: Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed.Conclusion: This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.Keywords: blood collection, nerve damage, motion analysis, patient safety, puncture angle, clinical education

  4. EUS – Fine- Needle Aspiration Biopsy (FNAB in the Diagnosis of Pancreatic Adenocarcinoma: A Review

    Directory of Open Access Journals (Sweden)

    Kalogeraki Alexandra

    2016-03-01

    Full Text Available Solid masses of the pancreas represent a variety of benign and malignant neoplasms of the exocrine and endocrine tissues of the pancreas. A tissue diagnosis is often required to direct therapy in the face of uncertain diagnosis or if the patient is not a surgical candidate either due to advanced disease or comorbidities. Endoscopic ultrasound (EUS is a relatively new technology that employs endoscopy and high-frequency ultrasound (US. EUS involves imaging of the pancreatic head and the uncinate from the duodenum and imaging of the body and tail from the stomach. It has been shown to be a highly sensitive method for the detection of pancreatic masses. It is superior to extracorporeal US and computed tomographic (CT scans, especially when the pancreatic tumor is smaller than 2-3 cm. Although EUS is highly sensitive in detecting pancreatic solid masses, its ability to differentiate between inflammatory masses and malignant disease is limited. Endoscopic retrograde cholangiopancreatography (ERCP brushing, CT-guided biopsies, and transabdominal ultrasound (US have been the standard nonsurgical methods for obtaining a tissue diagnosis of pancreatic lesions, but a substantial false-negative rate has been reported. Transabdominal US-guided fine-needle aspiration biopsy (US-FNAB has been used for tissue diagnosis in patients with suspected pancreatic carcinoma. It has been shown to be highly specific, with no false-positive diagnoses. With the advent of curvilinear echoendoscopes, transgastric and transduodenal EUS-FNAB of the pancreas have become a reality EUS with FNAB has revolutionized the ability to diagnose and stage cancers of the gastrointestinal tract and assess the pancreas. Gastrointestinal cancers can be looked at with EUS and their depth of penetration into the intestinal wall can be determined. Any suspicious appearing lymph nodes can be biopsied using EUS/FNAB. The pancreas is another organ that is well visualized with EUS. Abnormalities

  5. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  6. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  7. Risk of malignancy in fine-needle aspiration biopsy in patients with thyroid nodules

    DEFF Research Database (Denmark)

    Egset, Alice Viktoria; Holm, Camilla; Larsen, Stine Rosenkilde

    2017-01-01

    Introduction: Fine-needle aspiration biopsy (FNAB) is the cornerstone of thyroid nodule evaluation. In most cases, FNAB can discriminate between benign and malignant disease. In other cases, it is only indicative of malignancy and the results are considered “suspicious”. In Denmark, thyroid FNAB...

  8. Detection of suspicious malignant cervical lymph nodes of unknown origin: diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

    International Nuclear Information System (INIS)

    Lo, C.-P.; Chen, C.-Y.; Chin, S-.C.; Lee, K.-W.; Hsueh, C.-J.; Juan, C.-J.; Kao, H.-W.; Huang, G.-S.

    2007-01-01

    To assess the role of ultrasound-guided fine-needle aspiration biopsy (US-guided FNAB) in the diagnostic workup of suspicious malignant cervical lymph nodes in patients with palpable neck masses and without known primary cancer. The diagnostic accuracy of imaging morphologic criteria, including sizes and central necrosis for assessing suspicious malignant nodes, were also examined. This is a retrospective study of 426 patients with palpable neck masses from an outpatient department evaluated with computed tomography, magnetic resonance imaging, or US. US-guided FNABs were performed in 102 patients with suspicious malignant cervical lymph nodes at a single institution. Cytologically positive lymph nodes (n = 12) were further validated with excisional biopsy. Negative lymph nodes (n = 90) were either excised (n = 10) or followed up by imaging studies for at least one year (n = 80). The diagnostic accuracy of the FNABs along with the imaging findings of nodal sizes and presence of central necrosis, which were classified by a consensus of 2 radiologists, were assessed. Twelve malignant nodes were detected with US-guided FNAB with one false-positive and one false-negative result. The overall sensitivity, specificity, and accuracy for FNAB were 91.7%, 98.9%, and 98.0%. respectively. The sensitivity, specificity, and accuracy were 66.7%, 30.0%, and 34.3% for size criterion and 75.0%, 83.3%, and 82.3% for central necrosis criterion. The size of cervical lymph node does not appear to be an important imaging criterion for assessing suspicious malignant lymph nodes, compared with the criterion of central necrosis. US-guided FNAB is highly specific and sensitive in the diagnostic workup of suspicious malignant cervical lymph nodes in patients without known primary cancers. (author)

  9. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    Energy Technology Data Exchange (ETDEWEB)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Radiology - Sapienza, Rome (Italy); Anile, Marco; Venuta, Federico [University of Rome, Department of Thoracic Surgery - Sapienza, Rome (Italy); Vitolo, Domenico [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Pathology - Sapienza, Rome (Italy); Saba, Luca [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Monserrato (Italy); Longo, Flavia [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Oncology - Sapienza, Rome (Italy)

    2015-05-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  10. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    International Nuclear Information System (INIS)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo; Anile, Marco; Venuta, Federico; Vitolo, Domenico; Saba, Luca; Longo, Flavia

    2015-01-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  11. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  12. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  13. Fratura de agulha durante punção subaracnóidea: relato de caso Fractura de aguja durante punción subaracnóidea: relato de caso Needle fracture during spinal puncture: case report

    Directory of Open Access Journals (Sweden)

    Marcos G C Cruvinel

    2004-12-01

    introduction and consequent decrease in post dural puncture headache, spinal anesthesia is being increasingly used. Its complications are uncommon however recently we have observed a seemingly unusual complication: needle fracture during spinal puncture. This report aimed at describing the fact and at pointing its possible causes in addition to its prevention. CASE REPORT: Male patient, 53 years old, 90 kg, 175 cm, with chronic systemic hypertension and renal failure presented for emergency renal transplantation. Spinal morphine was proposed for postoperative analgesia. Puncture at L3-L4 with 27G needle was attempted without success, and was followed by attempt at L2-L3 when needle deformation was observed. Needle has broken at removal, leaving behind a 43 mm fragment in the L2-L3 interspinous ligament, which was confirmed by fluoroscopy. General anesthesia was induced and fragment was removed by fluoroscopic surgical exploration. Renal transplantation was then performed uneventfully. CONCLUSIONS: Decreased needle gauge has decreased post dural puncture headache but has also made needles fragiles. When ligaments are more resistant and puncture is attempted more than once there may be material stress leading to needle fracture. In conclusion, when there is increased resistance to needle introduction and puncture difficulty, the risk of deformation and potential fracture should be balanced against fine needle advantages.

  14. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  15. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    Science.gov (United States)

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  17. Conclusiveness of fine needle aspiration in 2419 histologically confirmed benign and malignant breast lesions

    NARCIS (Netherlands)

    Kooistra, B.; Wauters, C.; Wobbes, T.; Strobbe, L.

    2011-01-01

    We aimed to retrospectively assess (1) the conclusiveness of breast fine needle aspiration (FNA) in a histologically confirmed population and (2) the clinical and radiologic determinants of a conclusive diagnosis. Aspirates were diagnosed as inadequate, benign, atypical, suspicious or malignant. We

  18. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  19. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    Science.gov (United States)

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (pcytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  20. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  1. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  2. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  3. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  4. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety.

    Science.gov (United States)

    Fujii, Chieko

    2013-01-01

    Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures. Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined. Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed. This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.

  5. Cytomorphology of nipple discharge and fine needle aspiration of duct papilloma

    Directory of Open Access Journals (Sweden)

    H B Bannur

    2012-01-01

    Full Text Available The primary role of fine needle aspiration (FNA of the breast is the distinction between benign and malignant lesions; but in many cases, additional information may be obtained. The major breast lesions that yield papillary fragments on FNA are papillary carcinoma, papilloma, fibroadenoma, and invasive ductal carcinoma that have a papillary component. We present cytomorphological features of nipple discharge and FNA of breast lump in a 32-year female.

  6. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Fine-needle aspiration cytology in children with superficial lymphadenopathy

    Directory of Open Access Journals (Sweden)

    F. De Corti

    2014-04-01

    Full Text Available Introduction: In pediatric population Fine-Needle Aspiration Citology (FNAC is slowly gaining acceptance in clinical management of Superficial Lymphadenopathy (SL. Our experience adds some data about the usefulness of this technique in diagnosing the cause of a SL and therefore guiding further treatment. Patients and Methods: 238 FNAC were performed in 217 patients with SL, observed at our Institution from 2002 to 2006. The neck was the most frequent localization. The results were available within few hours. In cases of granulomatous findings, the samples were processed for microbiological and PCR test, in order to identify Mycobacteria. Results: 174 were reactive lesions, 38 granulomatous lymphadenopathies, 24 malignant lesions, 2 specimens inadequate for diagnosis. Among the 174 reactive SL, 22 required an incisional biopsy after 1 month follow-up. Among the granulomatous lymphadenopathies, 13 children with Cat-Scratch Disease recovered, 25 with Mycobacteria infection underwent surgical excision. For 24 malignant lesions, the diagnosis was confirmed by further biopsy. Two false negative and no false positive were detected (sensitivity 92%, specificity 100%. No complications were encountered. Conclusions: In our experience FNAC, performed by experienced cytopathologist, has revealed to be a fast, safe, non invasive and inexpensive method to achieve diagnosis in persistent SL. The use of FNAC gave us the possibility to select patients for further investigation and/or surgical treatment. Incisional biopsy remains necessary to confirm the diagnosis in case of malignancy or doubtful lesions.

  8. Two-miRNA classifiers differentiate mutation-negative follicular thyroid carcinomas and follicular thyroid adenomas in fine needle aspirations with high specificity

    DEFF Research Database (Denmark)

    Stokowy, Tomasz; Wojtas, Bartosz; Jarzab, Barbara

    2016-01-01

    Diagnosis of thyroid by fine needle aspiration is challenging for the "indeterminate" category and can be supported by molecular testing. We set out to identify miRNA markers that could be used in a diagnostic setting to improve the discrimination of mutation-negative indeterminate fine needle...... aspirations. miRNA high-throughput sequencing was performed for freshly frozen tissue samples of 19 RAS and PAX8/PPARG mutation-negative follicular thyroid carcinomas, and 23 RAS and PAX8/PPARG mutation-negative follicular adenomas. Differentially expressed miRNAs were validated by quantitative polymerase...... chain reaction in a set of 44 fine needle aspiration samples representing 24 follicular thyroid carcinomas and 20 follicular adenomas. Twenty-six miRNAs characterized by a significant differential expression between follicular thyroid carcinomas and follicular adenomas were identified. Nevertheless...

  9. Pancreatic duct drainage using EUS-guided rendezvous technique for stenotic pancreaticojejunostomy.

    Science.gov (United States)

    Takikawa, Tetsuya; Kanno, Atsushi; Masamune, Atsushi; Hamada, Shin; Nakano, Eriko; Miura, Shin; Ariga, Hiroyuki; Unno, Jun; Kume, Kiyoshi; Kikuta, Kazuhiro; Hirota, Morihisa; Yoshida, Hiroshi; Katayose, Yu; Unno, Michiaki; Shimosegawa, Tooru

    2013-08-21

    The patient was a 30-year-old female who had undergone excision of the extrahepatic bile duct and Roux-en-Y hepaticojejunostomy for congenital biliary dilatation at the age of 7. Thereafter, she suffered from recurrent acute pancreatitis due to pancreaticobiliary maljunction and received subtotal stomach-preserving pancreaticoduodenectomy. She developed a pancreatic fistula and an intra-abdominal abscess after the operation. These complications were improved by percutaneous abscess drainage and antibiotic therapy. However, upper abdominal discomfort and the elevation of serum pancreatic enzymes persisted due to stenosis from the pancreaticojejunostomy. Because we could not accomplish dilation of the stenosis by endoscopic retrograde cholangiopancreatography, we tried an endoscopic ultrasonography (EUS) guided rendezvous technique for pancreatic duct drainage. After transgastric puncture of the pancreatic duct using an EUS-fine needle aspiration needle, the guidewire was inserted into the pancreatic duct and finally reached to the jejunum through the stenotic anastomosis. We changed the echoendoscope to an oblique-viewing endoscope, then grasped the guidewire and withdrew it through the scope. The stenosis of the pancreaticojejunostomy was dilated up to 4 mm, and a pancreatic stent was put in place. Though the pancreatic stent was removed after three months, the patient remained symptom-free. Pancreatic duct drainage using an EUS-guided rendezvous technique was useful for the treatment of a stenotic pancreaticojejunostomy after pancreaticoduodenectomy.

  10. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    Science.gov (United States)

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  11. CT and MRI-based door-needle-times for acute stroke patients a quasi-randomized clinical trial

    DEFF Research Database (Denmark)

    Hansen, Christine Krarup; Christensen, Anders; Rodgers, Helen

    2017-01-01

    OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI)-based-evaluation ......OBJECTIVES: Door-Needle-times (DNT) of 20min are feasible when Computer Tomography (CT) is used for first-line brain-imaging to assess stroke-patients' eligibility for intravenous-tissue-Plasminogen-Activator (iv-tPA), but the more time-consuming Magnetic Resonance Imaging (MRI...

  12. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  13. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  14. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  15. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  16. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  17. Spinal anaesthesia in young patients: evaluation of needle gauge ...

    African Journals Online (AJOL)

    Background:The well-known complication of spinal anaesthesia, postdural puncture headache (PDPH), is especially troublesome in young patients. The needle gauge and configuration of needle tip appear to be the important factors in reducing the incidence of PDPH; however it may increase the incidence of technical ...

  18. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  19. The effect of second-stage pushing and body mass index on postdural puncture headache.

    Science.gov (United States)

    Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S

    2017-02-01

    To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; Ppushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  1. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  2. The reasons for delay lumbar puncture

    Directory of Open Access Journals (Sweden)

    MH. Lotfi

    2017-04-01

    Full Text Available Early diagnosis of meningitis and encephalitis and prompt initiation of appropriate therapy is vital and any delay will lead to high mortality and serious and permanent morbidity. The main purpose of this study was to evaluate the management of 220 patients with suspected central nervous system (CNS infections (meningitis and encephalitis to determine the percentage of patients’ suspected CNS infection undergo lumbar puncture in acceptable time (in accordance with conventional algorithms. In this descriptive study, patients with suspected CNS infections admitted to Bu-Ali and Qods hospitals, in the period July 2013 to December 2015 were studied. Information of 220 patients was collected. Continuous variables were summarized as means ± standard deviation and categorical variables as frequencies and percentages. Lumbar puncture (LP in patients was delayed in 200 cases (91%. Most common causes of delay in performing LP were prolongation of the process of determining patient needs to puncture, satisfying patients, CT scan delay and the delay in allowing LP by neurologist. In this study, delaying LP rate was higher than other studies. It seems certain pattern in assistants’ visits for counseling. CT requests and neurologic consultation before LP performed for all adult patients.

  3. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  4. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  5. Target motion predictions for pre-operative planning during needle-based interventions

    NARCIS (Netherlands)

    op den Buijs, J.; Abayazid, Momen; de Korte, Chris L.; Misra, Sarthak

    During biopsies, breast tissue is subjected to displacement upon needle indentation, puncture, and penetration. Thus, accurate needle placement requires pre-operative predictions of the target motions. In this paper, we used ultrasound elastography measurements to non-invasively predict elastic

  6. Evaluation of the tumor registration error in biopsy procedures performed under real-time PET/CT guidance.

    Science.gov (United States)

    Fanchon, Louise M; Apte, Adytia; Schmidtlein, C Ross; Yorke, Ellen; Hu, Yu-Chi; Dogan, Snjezana; Hatt, Mathieu; Visvikis, Dimitris; Humm, John L; Solomon, Stephen B; Kirov, Assen S

    2017-10-01

    The purpose of this study is to quantify tumor displacement during real-time PET/CT guided biopsy and to investigate correlations between tumor displacement and false-negative results. 19 patients who underwent real-time 18 F-FDG PET-guided biopsy and were found positive for malignancy were included in this study under IRB approval. PET/CT images were acquired for all patients within minutes prior to biopsy to visualize the FDG-avid region and plan the needle insertion. The biopsy needle was inserted and a post-insertion CT scan was acquired. The two CT scans acquired before and after needle insertion were registered using a deformable image registration (DIR) algorithm. The DIR deformation vector field (DVF) was used to calculate the mean displacement between the pre-insertion and post-insertion CT scans for a region around the tip of the biopsy needle. For 12 patients one biopsy core from each was tracked during histopathological testing to investigate correlations of the mean displacement between the two CT scans and false-negative or true-positive biopsy results. For 11 patients, two PET scans were acquired; one at the beginning of the procedure, pre-needle insertion, and an additional one with the needle in place. The pre-insertion PET scan was corrected for intraprocedural motion by applying the DVF. The corrected PET was compared with the post-needle insertion PET to validate the correction method. The mean displacement of tissue around the needle between the pre-biopsy CT and the postneedle insertion CT was 5.1 mm (min = 1.1 mm, max = 10.9 mm and SD = 3.0 mm). For mean displacements larger than 7.2 mm, the biopsy cores gave false-negative results. Correcting pre-biopsy PET using the DVF improved the PET/CT registration in 8 of 11 cases. The DVF obtained from DIR of the CT scans can be used for evaluation and correction of the error in needle placement with respect to the FDG-avid area. Misregistration between the pre-biopsy PET and the CT acquired with the

  7. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  8. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F.; Bretschneider, T.; Hartwig, T.; Disch, A.C.

    2014-01-01

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  9. Open magnetic resonance imaging using titanium-zirconium needles: improved accuracy for interstitial brachytherapy implants?

    International Nuclear Information System (INIS)

    Popowski, Youri; Hiltbrand, Emile; Joliat, Dominique; Rouzaud, Michel

    2000-01-01

    Purpose: To evaluate the benefit of using an open magnetic resonance (MR) machine and new MR-compatible needles to improve the accuracy of brachytherapy implants in pelvic tumors. Methods and Materials: The open MR machine, foreseen for interventional procedures, allows direct visualization of the pelvic structures that are to be implanted. For that purpose, we have developed MR- and CT-compatible titanium-zirconium (Ti-Zr) brachytherapy needles that allow implantations to be carried out under the magnetic field. In order to test the technical feasibility of this new approach, stainless steel (SS) and Ti-Zr needles were first compared in a tissue-equivalent phantom. In a second step, two patients implanted with Ti-Zr needles in the brachytherapy operating room were scanned in the open MR machine. In a third phase, four patients were implanted directly under open MR control. Results: The artifacts induced by both materials were significantly different, strongly favoring the Ti-Zr needles. The implantation in both first patients confirmed the excellent quality of the pictures obtained with the needles in vivo and showed suboptimal implant geometry in both patients. In the next 4 patients, the tumor could be punctured with excellent accuracy, and the adjacent structures could be easily avoided. Conclusion: We conclude that open MR using MR-compatible needles is a very promising tool in brachytherapy, especially for pelvic tumors

  10. CT-guided percutaneous lung biopsy: Comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grand, David Justin, E-mail: dgrand@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Atalay, Michael A., E-mail: matalay@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Cronan, John J., E-mail: cronan@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Mayo-Smith, William W., E-mail: wmayo-smith@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States)

    2011-08-15

    Purpose: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm. Materials/methods: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below. Results: Average fluoroscopy time using CTF was 28.2 s compared to 35.0 s for EMN (p = 0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p = 0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p = 0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p = 0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p = 0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p = 0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p = 0.4). Conclusions: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.

  11. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    OpenAIRE

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial...

  12. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  13. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Science.gov (United States)

    Wallace, John R; Mangas, Kirstie M; Porter, Jessica L; Marcsisin, Renee; Pidot, Sacha J; Howden, Brian; Omansen, Till F; Zeng, Weiguang; Axford, Jason K; Johnson, Paul D R; Stinear, Timothy P

    2017-04-01

    Addressing the transmission enigma of the neglected disease Buruli ulcer (BU) is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti) blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24) subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50) in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  14. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Directory of Open Access Journals (Sweden)

    John R Wallace

    2017-04-01

    Full Text Available Addressing the transmission enigma of the neglected disease Buruli ulcer (BU is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24 subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50 in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  15. Calcitonin assay in wash-out fluid after fine-needle aspiration biopsy in patients with a thyroid nodule and border-line value of the hormone.

    Science.gov (United States)

    Massaro, F; Dolcino, M; Degrandi, R; Ferone, D; Mussap, M; Minuto, F; Giusti, M

    2009-04-01

    Assaying calcitonin (CT) in the wash-out fluid from fine-needle aspiration biopsies (CT-FNAB) could be useful in the diagnosis of medullary thyroid carcinoma (MTC). The aim of this study was to correlate serum CT with cytology and CT-FNAB. Twenty-seven subjects (age range 27-75 yr) were studied. FNAB was performed in a thyroid nodule (no.=16) or lymph-node (no.=1 previously operated on for MTC) or in the prevalent nodule of multinodular goiters (no.=10). CT-FNAB values obtained in 37 subjects with normal serum CT (thyroid nodules served as a negative control. In these subjects, CTFNAB values were 8.2+/-6.4 ng/l (range 2-30 ng/l). In patients with a thyroid nodule under evaluation for MTC, serum CT and CT-FNAB values were 14.5+/-3.9 ng/l (range 10-24 ng/l) and 16.4+/-29.8 ng/l (range 2-144 ng/l), respectively. In 4 patients, CT-FNAB values were higher than the highest values found in our negative controls (30 ng/l), but cytology results were compatible with a benign thyroid lesion and pentagastrin testing was negative. In 3 cases with CT-FNAB 100 ng/l. Our data do not show any correlation between CT-FNAB and serum CT. In conclusion, borderline CT values in patients with thyroid nodules are not rare. Our experience suggests that CT-FNAB does not have the same importance as that reported in the literature for thyroglobulin and PTH assay in wash-out fluid after FNAB in malignant thyroid and hyperfunctioning parathyroid lesions.

  16. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    Science.gov (United States)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  17. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  18. Value of fine-needle aspiration biopsy of salivary gland lesions

    DEFF Research Database (Denmark)

    Christensen, Rikke Kølby; Bjørndal, Kristine; Godballe, Christian

    2010-01-01

    BACKGROUND: The aim of this study was to assess the utility of fine-needle aspiration biopsy (FNAB) in the diagnosis and treatment planning of the lesions of the salivary gland. METHODS: Eight hundred seventy-nine aspiration biopsies of the lesion of the salivary gland over a 10-year period, from...... was 98%, and the negative predictive value was 97%. The overall accuracy was 93%. The correct subtyping of the benign lesions was 97%, and the exact type-specific concordance of the malignant lesions was 71%. CONCLUSION: Considerable benefit to the patient may result from the cautious use of FNAB...

  19. Patterns of lymphadenopathy on fine needle aspiration cytology in eastern Nepal

    Directory of Open Access Journals (Sweden)

    N Mainali

    2015-09-01

    Full Text Available BACKGROUND: Lymphadenopathy is a commonly encountered clinical problem. Fine needle aspiration cytology offers the alternative of an immediate, preliminary, although not always specific diagnosis with little trauma and cost, thus providing ample information for further management and reduce the amount of open biopsy.MATERIAL AND METHODS:  FNAC was performed using 21 gauge needle attached with 10ml disposable needle. Slides were prepared, two were air dried and stained with field stain where as two were fixed in ethanol and was stained with PAP stain. One slide was stained with Ziehl-Neelson stain. Field and PAP stained slide were reviewed and diagnosed by Pathologist.RESULT: Out of the 225 patients, reactive lymphadenitis was the most common diagnosis (54.2%, followed by tubercular lymphadenitis (33.44%. Among the age group percentage of tubercular lymphadenitis was more in 210-30 years of age.  Majority of the metastatic carcinoma was in cervical region, comprising mainly squamous cell carcinoma.CONCLUSION: Reactive lymphadenitis was the most common cause of lymphadenopathy especially in case of children. In case of older population, definite pathology for lymph node enlargement was found in most of the cases. Hence FNAC is warranted in lymphadenopathy, as it is simple yet of great diagnostic value.

  20. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  1. Cefalea secundaria a punción dural Headache as a result of dural puncture

    Directory of Open Access Journals (Sweden)

    Ariadna García Rodríguez

    2005-03-01

    Full Text Available Se realizó una revisión bibliográfica sobre cefalea pospunción en el Hospital "Abel Santamaría", de Pinar del Río, en el período comprendido de febrero a junio del 2004, con el objetivo de ampliar los conocimientos de los profesionales de la salud encargados de diagnosticar y tratar esta complicación. La cefalea secundaria a punción dural se debe al escape persistente de LCR (líquido cefalorraquídeo a través del desgarro hecho en la duramadre, causado por la penetración de la aguja; se presenta cuando el paciente adopta la posición erecta y se alivia con el decúbito, característica esta que de no aparecer debe hacer dudar el diagnóstico. La elección de un trocar fino para realizar la punción y la dirección del bisel paralelo a las fibras de la duramadre son los factores determinantes en la profilaxis de la cefalea. Aún existen controversias en cuanto a su tratamiento, pero si hay un consenso unido en que el parche de sangre epidural es el tratamiento definitivo de esta complicación.A review of the most updated literature on dural post-puncture headache was made at Abel Santamaría University Hospital in February - June 2004 aimed at spreading the awareness to health professionals at diagnosing and treating this condition. The headache secondary to dural puncture is caused by the persistent leakage of cerebrospinal fluid through the dura tear because of the needle insertion; it presents when the patient adopts the erect position and it alleviates with the supine position; if this characteristic is not present it may appear some doubts on diagnosis. The selection of a fine trocar for puncture and guiding the bevel parallel to the fibers of dura are the main factors for profilaxis of headache. Its treatment is controversial, but it does exist a consensus in that the epidural blood patch is the definitive treatment for this condition.

  2. Fine needle aspiration diagnosis of a spontaneously infarcted fibroadenoma mimicking carcinoma: a case report.

    Science.gov (United States)

    Arora, Rajan; Abou-Bakr, Amany; Al Taleb, Ahmed

    2013-02-01

    Spontaneous infarction of fibroadenoma is an extremely rare complication in a nonpregnant/nonlactating female undergoing first-time aspiration. It can be misdiagnosed as carcinoma in all aspects of triple approach used for evaluation of patients with breast lesions. A 37-year-old woman presented to the outpatient surgical clinic with a 6-month history of a breast lump that was slowly increasing in size and had become painful during the past month. There was no history of any trauma or fine needle aspiration, and she was not pregnant or lactating. Mammogram and ultrasound revealed a 2.9-cm heterogenous hypoechoic suspicious lesion. No lymph nodes were detected in the axilla. Fine needle aspiration cytology was performed, and a diagnosis of benign breast lesion with features of infarction was rendered on cytology. The lump was excised surgically, and a histological diagnosis of infarcted fibroadenoma was made. Careful and diligent search for preserved benign epithelial cells on smears is the key to recognize this entity and avoid serious therapeutic implications.

  3. CASE REPORT:Chondrosarcoma of Rib on Fine Needle Aspiration Cytology – A Rare Site

    Directory of Open Access Journals (Sweden)

    Prakash M Patil

    2012-07-01

    Full Text Available Background: Fine needle aspiration cytology (FNAC is effective in the diagnosis of bone tumors when combined with careful radiologic and clinical evaluation. Chondrosarcomas often arise in the pelvis or bones of the trunk, but primary chest wall (rib chondrosarcomas are relatively rare. Case Reports: This is a case of a patient with a chondrosarcoma arising in the left lower rib who underwent resection. The patient was a 30-year-old man with a 10x8x6cm tumor in the anterior chest wall of the left side lower rib. On Fine Needle Aspiration Cytology (FNAC of the mass on the anterior chest wall, a diagnosis of a low grade chondrosarcoma was made. This was confirmed histopathologically as a dedifferentiated chondrosarcoma. Macroscopically on excision of gray to pink lobulated mass with adjacent soft tissue and bone with foci of hemorrhage and necrosis the mass measured (M 10x 8x 6 cm. Incidence of chondrosarcoma peaks in the 5th to 6th decade and most commonly involves the femur, humerus, pelvis, and scapula. It rarely involves rib.

  4. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  5. Simple localization of peripheral pulmonary nodules - CT-guided percutaneous hook-wire localization

    International Nuclear Information System (INIS)

    Poretti, F.P.; Vorwerk, D.; Brunner, E.

    2002-01-01

    Background: Video-assisted thoracoscopic surgery (VATS) is an alternative approach to small intrapulmonary nodules, if transbronchial or percutaneous biopsy have failed. We investigated the feasibility and effectiveness of the percutaneous CT-guided placement of hook-wires to localize such nodules before video-assisted thoracoscopy. Subjects and Methods: 19 patients with new by diagnosed intrapulmonary nodules underwent CT-guided hook-wire localization by application of a X-Reidy-Set (Cook, Inc., Bjaeverskov, Denmark). The average age of the patient was 63 years (range: 19-80 years), the mean distance between the nodule and the pleura visceral was 7.58 mm (range: 0-25 mm) and the mean diameter was 11.58 mm (range: 5-25 mm). After localization, the patients underwent a VATS resection of the lesion within a mean time of 30 min (range 10-48 min). Results: In all cases, resection of the nodules was successful. In 4 older patients the marking was complicated by poor cooperability. At the end of manipulation the end of the hook was distanced from the nodule. But also in these cases, resection was successfully performed. 8 patients developed an asymptomatic pneumothorax: 5 of them in a minor (max. 1.5 cm rim), three of them in a moderate (max. 3 cm rim) dimension. In 4 patients, in whom the tumor was hit directly by the needle, local bleeding occurred. In one case, haemoptoe was present. In no patient did a dislocation of the hookwire-system occur. Conclusion: CT-guided placement of a hook-wire system is a simple and reasonable procedure which facilitates safe VATS resection of small pulmonary nodules. (orig.) [de

  6. Testicular fine-needle aspiration for the assessment of intratesticular hormone concentrations

    Directory of Open Access Journals (Sweden)

    Ada P Lee

    2016-01-01

    Full Text Available Measurement of intratesticular sex steroid concentrations in men informs both the development of male hormonal contraceptives and the understanding of male infertility. Given the challenges of using invasive techniques to measure testicular hormone physiology, our group has used a minimally-invasive fine-needle aspiration technique to measure intratesticular hormones in normal healthy men. Herein, we present a post-hoc analysis of the safety and efficacy of testicular fine-needle aspiration (FNA completed as part of six clinical trials. From 2001 through 2011, a total of 404 procedures were conducted among 163 research volunteers, 85.9% of which were successful in obtaining sufficient fluid for the measurement of intratesticular steroid concentrations. Pain was the most common side effect, with 36.8% of procedures associated with moderate procedural pain and 4.7% with severe procedural pain. Postprocedural pain was uncommon and abated within a few days. Mild local bruising occurred with 14.9% of procedures. Two serious adverse events (0.5% required surgical intervention. The risk of an adverse event was not associated with age, body mass index, testicular size, or the volume of fluid aspirated. Testicular FNA to obtain fluid for measurement of intratesticular steroid concentrations frequently causes mild to moderate procedural pain, but serious adverse events occur rarely. Testicular FNA has been instrumental for defining human intratesticular hormone physiology and is a minimally-invasive, safe, effective method for obtaining fluid for research on testicular physiology and pathology.

  7. WE-AB-BRA-04: Evaluation of the Tumor Registration Error in Biopsy Procedures Performed Under Real Time PET/CT Guidance

    International Nuclear Information System (INIS)

    Fanchon, L; Apte, A; Dzyubak, O; Mageras, G; Yorke, E; Solomon, S; Kirov, A; Visvikis, D; Hatt, M

    2015-01-01

    Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not been previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A

  8. Technological advances and changing indications for lumbar puncture in neurological disorders.

    Science.gov (United States)

    Costerus, Joost M; Brouwer, Matthijs C; van de Beek, Diederik

    2018-03-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal autoantibodies in autoimmune encephalitis. New screening techniques have increased sensitvity for pathogen detection and can be used to identify pathogens that were previously unknown to cause CNS infections. Evidence suggests that potential treatments for neurodegenerative diseases, such as Alzheimer's disease, will rely on early detection of the disease with the use of CSF biomarkers. In addition to being used as a diagnostic tool, lumbar puncture can also be used to administer intrathecal treatments as shown by studies of antisense oligonucleotides in patients with spinal muscular atrophy. Lumbar puncture is generally a safe procedure but complications can occur, ranging from minor (eg, back pain) to potentially devastating (eg, cerebral herniation). Evidence that an atraumatic needle tip design reduces complications of lumbar puncture is compelling, and reinforces the need to change clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  10. Technical compliance to standard guidelines for lumbar puncture and myelography: survey of academic neuroradiology attendings and fellows.

    Science.gov (United States)

    Zhang, Yi C; Chandler, Alexander J; Kagetsu, Nolan J

    2014-05-01

    To assess technical compliance among neuroradiology attendings and fellows to standard guidelines for lumbar puncture and myelography to minimize procedural complications such as iatrogenic meningitis and spinal headache. We surveyed academic neuroradiology attendings and fellows in the e-mail directory of the Association of Program Directors in Radiology. We queried use of face masks, use of noncutting needles, and dural puncture practices. All data were collected anonymously. A total of 110 survey responses were received: 75 from neuroradiology attendings and 34 from fellows, which represents a 14% response rate from a total of 239 fellows. Forty-seven out of 101 (47%) neuroradiologists do not always wear a face mask during myelograms, and 50 out of 105(48%) neuroradiologists do not always wear a face mask during lumbar punctures, placing patients at risk for iatrogenic meningitis. Ninety-six out of 106 neuroradiologists (91%) use the Quincke cutting needle by default, compared to only 17 out of 109 neuroradiologists (16%) who have ever used noncutting needles proven to reduce spinal headache. Duration of postprocedure bed rest does not influence incidence of spinal headache and may subject patients to unnecessary monitoring. Only 15 out of 109 (14%) neuroradiologists in our study do not prescribe bed rest. There was no statistically significant difference in practice between attendings and fellows. Iatrogenic meningitis and spinal headache are preventable complications of dural puncture that neuroradiologists can minimize by conforming to procedural guidelines. Wearing face masks and using noncutting spinal needles will reduce patient morbidity and lower hospitalization costs associated with procedural complications. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  11. Concomitant Intracranial and Lumbar Chronic Subdural Hematoma Treated by Fluoroscopic Guided Lumbar Puncture: A Case Report and Literature Review

    Science.gov (United States)

    ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi

    2018-01-01

    A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039

  12. Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L; Cutkosky, Mark R

    2014-09-01

    This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).

  13. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun [Ajou Univ., Suwon (Korea, Republic of). Coll. of Medicine

    1998-04-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs.

  14. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    International Nuclear Information System (INIS)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun

    1998-01-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs

  15. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  16. MR-guided perineural injection of the ganglion impar: technical considerations and feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Marker, David R.; Carrino, John A.; Fritz, Jan [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Musculoskeletal Radiology, Baltimore, MD (United States); U-Thainual, Paweena [Queen' s University, Department of Mechanical and Materials Engineering, Kingston, ON (Canada); Ungi, Tamas; Fichtinger, Gabor [Queen' s University, School of Computing, Kingston, ON (Canada); Flammang, Aaron J. [Siemens Corporate Research, Center for Applied Medical Imaging, Baltimore, MD (United States); Iordachita, Iulian I. [Johns Hopkins University, Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Baltimore, MD (United States)

    2016-05-15

    Perineural ganglion impar injections are used in the management of pelvic pain syndromes; however, there is no consensus regarding the optimal image guidance. Magnetic resonance imaging (MRI) provides high soft tissue contrast and the potential to directly visualize and target the ganglion. The purpose of this study was to assess the feasibility of MR-guided percutaneous perineural ganglion impar injections. Six MR-guided ganglion impar injections were performed in six human cadavers. Procedures were performed with a clinical 1.5-Tesla MRI system through a far lateral transgluteus approach. Ganglion impar visibility, distance from the sacrococcygeal joint, number of intermittent MRI control steps required to place the needle, target error between the intended and final needle tip location, inadvertent punctures of non-targeted vulnerable structures, injectant distribution, and procedure time were determined. The ganglion impar was seen on MRI in 4/6 (66 %) of cases and located 0.8 mm cephalad to 16.3 mm caudad (average 1.2 mm caudad) to the midpoint of the sacrococcygeal joint. Needle placement required an average of three MRI control steps (range, 2-6). The average target error was 2.2 ± 2.1 mm. In 6/6 cases (100 %), there was appropriate periganglionic distribution and filling of the presacrococcygeal space. No punctures of non-targeted structures occurred. The median procedure time was 20 min (range, 12-29 min). Interventional MRI can visualize and directly target the ganglion impar for accurate needle placement and successful periganglionic injection with the additional benefit of no ionizing radiation exposure to patient and staff. Our results support clinical evaluation. (orig.)

  17. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  18. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    Science.gov (United States)

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  19. Transthoracic needle biopsy: factors effecting risk of pneumothorax

    International Nuclear Information System (INIS)

    Topal, Ugur; Ediz, Buelent

    2003-01-01

    Objective: to evaluate the factors that could effect the risk of pneumothorax in patients undergoing transthoracic biopsy. Material and methods: variables that could increase the risk of pneumothorax were evaluated in 453 CT-guided transthoracic biopsies. Factors were evaluated in two groups: (1) lesion related (presence of emphysema around the lesion, lesion depth, cavitation, presence of fissure/atelectasis and pleural tag in the needle trajectory); and (2) procedure related (biopsy type, needle size, number of passages, level of experience of the operator). All variables were analysed by χ 2 test and multivariate logistic regression statistics. Results: pneumothorax was developed in 85 (18.8%) out of 453 procedures. A chest tube was inserted in ten (11.7%) of them. Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P<0.001) and severity of the emphysema (P<0.01). Conclusion: the length of the lung parenchyma traversed during the biopsy is the predominant risk factor for pneumothorax in patients undergoing CT-guided transthoracic biopsy. The risk of pneumothorax was also increased with the severity of the emphysema around the lesion

  20. The diagnosis of cerebrospinal fluid hypovolemia. The comparison between CT myelography and RI cisternography

    International Nuclear Information System (INIS)

    Watanabe, Keisuke; Hashizume, Keiji; Inoue, Satoki; Fujiwara, Aki; Furuya, Hitoshi

    2008-01-01

    The comparison in the title is performed in cases with suspicious hypovolemia of cerebrospinal fluid (CSF) and its leak at the lumbar region is also examined in whiplash injury. Subjects are 25 cases (M 14/F 11, av. age 36.9 y) with traffic (13 cases), whiplash (4) and null (8) injuries. CT myelography (CTM) is conducted by injection of iotrolan through the lumbar puncturing needle to get 700 images of the whole spine of 1 mm slice thickness, which after animated, are observed visually. RI cisternography (RIC) is done immediately, 2 and 24 hr after injection of 10 MBq of diethylenetriamine pentaacetic acid (DTPA)-In through the puncturing needle. In 15 cases exhibiting positive RIC findings, CTM gives a positive leak at cervical and thoracic regions only in 2 cases and a false positive in other 13. In contrast, RIC fails to detect 2 cases of 4 with a leak at cervical and thoracic regions. Thus RIC is less reliable, and often observable RI accumulation at the lumbar area in RIC is not always a leak. (R.T.)

  1. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  2. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  3. [Dose-response relationship of ropivacaine for epidural block in early herpes zoster guided by CT].

    Science.gov (United States)

    Xie, K Y; Ma, J B; Xu, Q; Huang, B; Yao, M; Ni, H D; Deng, J J; Chen, G D

    2017-12-26

    Objective: To determine the dose-response relationship of ropivacaine for epidural block in early herpes zoster by CT guided. Methods: From January 2015 to February 2017, according to the principle of completely random digital table, 80 patients with early herpes zoster who were prepared for epidural block were divided into 4 groups(each group 20 patients): in group A the concentration of ropivacaine was 0.08%, in group B was 0.10%, in group C was 0.12% and in group D was 0.14%.Under CT guidance, epidural puncture was performed in the relevant section, mixing liquid 5.0 ml (with 10% iodohydrin)were injected into epidural gap.CT scan showed that the mixing liquid covered the relevant spinal nerve segmental.The numeric rating scale(NRS) values before treatment and at 30 minutes, the incidence of adverse reactions were recorded, and the treatment were evaluated. The response to ropivacaine for epidural block in early herpes zoster was defined as positive when the NRS values was less than or equal to one.The ED(50), ED(95) and 95% confidence interval ( CI ) of ropivacaine for epidural block in early herpes zoster guided by CT were calculated by probit analysis. Results: The NRS values before treatment were 5.00(4.00, 6.00), 5.00(4.25, 6.00), 5.50(5.00, 6.00) and 5.00(4.00, 6.00), the difference was no significant( Z =2.576, P =0.462). The NRS values at 30 minutes decreased and the effective rate of the treatment increased(χ(2)=8.371, P =0.004), following ropivacaine dose gradient increasing, they were 1.50(1.00, 2.00), 1.00(1.00, 2.00), 0.50(0.00, 1.00) and 0.00(0.00, 1.00), the difference was statistically significant ( Z =17.421, P =0.001). There was one case in group C and four cases in group D were hypoesthesia, others were no significant adverse reactions occurred. The ED(50) and ED(95) (95% CI ) of ropivacaine for epidural block in early herpes zoster guided by CT were 0.078%(0.015%-0.095%)and 0.157%(0.133%-0.271%), respectively. Conclusion: Ropivacaine for

  4. Role of AgNORs in thyroid lesions on fine needle aspiration cytology smears

    Directory of Open Access Journals (Sweden)

    Asotra Sarita

    2008-01-01

    Full Text Available Background: Fine needle aspiration has an important role in diagnosis of thyroid neoplasm. However, it is difficult to differentiate between follicular adenoma and follicular carcinoma by cytology alone. Recently, silver staining has been performed for nucleolar organizer regions (AgNORs to differentiate various tumors. Aims: The present study was undertaken to see if the AgNOR technique could distinguish between benign and malignant lesions, particularly, follicular neoplasm. Materials and Methods: One hundred forty cases of thyroid lesions were examined, which included colloid goiter (n = 36, multinodular goiter (n = 38, subacute thyroiditis (n = 6, Hashimoto′s thyroiditis (n = 17, lymphocytic thyroiditis (n = 3, follicular neoplasm (n = 18, Hurthle cell neoplasm (n = 3, papillary carcinoma (n = 16, and medullary carcinoma (n = 3. Diagnosis was confirmed by histopathology in 80 cases. The usual one-step silver colloidal reaction was performed at room temperature for 35 minutes and intranuclear dots of silver deposits were counted in 100 cells. Results: AgNOR counts of benign and malignant lesions were compared and were found to be statistically significant (P < 0.001. The mean AgNOR counts were higher in neoplastic lesions. Conclusions: AgNOR counting in fine needle aspiration smears is a simple, sensitive, and cost-effective method for differentiating benign from malignant thyroid follicular neoplasms.

  5. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  6. Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.

    Science.gov (United States)

    Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir

    2010-01-01

    In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.

  7. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    Science.gov (United States)

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  8. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  9. Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration.

    Science.gov (United States)

    Leung, Vincent A; Kirpalani, Anish; Mnatzakanian, Gevork; Colak, Errol; Vlachou, Paraskevi A

    2017-08-01

    The purpose of this study was to investigate the effect of a biopsy center-a dedicated space with a dedicated ultrasound machine and technologist, staffed daily by a radiologist responsible for performing ultrasound-guided procedures only-on the rate of non-diagnostic or unsatisfactory thyroid fine-needle aspiration (FNA). Three radiologists performed FNA on 1200 nodules in 998 patients between September 2010 and November 2015. We compared rates of nondiagnostic or unsatisfactory FNA before and after implementation of a biopsy center in September 2014 as part of a quality improvement initiative. Before the establishment of our biopsy center, ultrasound-guided procedures were scheduled between diagnostic studies in the main ultrasound department and were performed by a radiologist responsible for both. Multivariate logistic regression analysis was performed to assess the effect of the biopsy center on the odds of obtaining an adequate sample. Rates of nondiagnostic or unsatisfactory FNA decreased significantly from 15.1% to 8.5% (p < 0.001) after implementation of the biopsy center. The odds of obtaining an adequate sample were higher in the biopsy center (odds ratio, 2.07; 95% CI, 1.43-3.01), even after adjusting for patient age, nodule size, the radiologist performing the procedure, and time over the study period. The implementation of a biopsy center was associated with significantly lower rates of nondiagnostic or unsatisfactory thyroid FNA, suggesting target rates of 10% or lower are achievable with quality improvement measures.

  10. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    Directory of Open Access Journals (Sweden)

    Raquel Garza-Guajardo

    2005-09-01

    Full Text Available Abstract Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures.

  11. Image-guided fine needle cytology with aspiration versus non-aspiration in retroperitoneal masses: is aspiration necessary?

    Science.gov (United States)

    Misra, Rajiv Kumar; Mitra, Shaila; Jain, Rishav Kumar; Vahikar, Shilpa; Bundela, Archana; Misra, Purak

    2015-03-01

    Although using fine needle cytology with aspiration (FNC-A) for establishing diagnoses in the retroperitoneal region has shown promise, there is scant literature supporting a role of non-aspiration cytology (FNC-NA) for this region. We assessed the accuracy and reliability of FNC-A and FNC-NA as tools for preoperative diagnosis of retroperitoneal masses and compared the results of both techniques with each other and with histopathology. Fifty-seven patients with retroperitoneal masses were subjected to FNC-A and FNC-NA. Smears were stained with May-Grunwald Giemsa and hematoxylin and eosin stain. An individual slide was objectively analysed using a point scoring system to enable comparison between FNC-A and FNC-NA. By FNC-A, 91.7% accuracy was obtained in cases of retroperitoneal lymph node lesions followed by renal masses (83.3%). The diagnostic accuracy of other sites by FNC-A varied from 75.0%-81.9%. By FNC-NA, 93.4% diagnostically accurate results were obtained in the kidney, followed by 75.0% in adrenal masses. The diagnostic accuracy of other sites by FNC-NA varied from 66.7%-72.8%. Although both techniques have their own advantages and disadvantages, FNC-NA may be a more efficient adjuvant method of sampling in retroperitoneal lesions.

  12. Design and validation of a CT-guided robotic system for lung cancer brachytherapy.

    Science.gov (United States)

    Dou, Huaisu; Jiang, Shan; Yang, Zhiyong; Sun, Luqing; Ma, Xiaodong; Huo, Bin

    2017-09-01

    Currently, lung brachytherapy in clinical setting is a complex procedure. Operation accuracy depends on accurate positioning of the template; however, it is difficult to guarantee the positioning accuracy manually. Application of robotic-assisted systems can simplify the procedure and improve the manual positioning accuracy. Therefore, a novel CT-guided robotic system was developed to assist the lung cancer brachytherapy. A four degree-of-freedom (DOF) robot, controlled by a lung brachytherapy treatment planning system (TPS) software, was designed and manufactured to assist the template positioning. Target position of the template can be obtained from the treatment plan, thus the robot is driven to the target position automatically. The robotic system was validated in both the laboratory and the CT environment. In laboratory environment, a 3D laser tracker and an inertial measurement unit (IMU) were used to measure the mechanical accuracy in air, which includes positioning accuracy and position repeatability. Working reliability was also validated in this procedure by observing the response reliability and calculating the position repeatability. Imaging artifacts and accuracy of the robot registration were validated in the CT environment by using an artificial phantom with fiducial markers. CT images were obtained and used to test the image artifact and calculate the registration accuracy. Phantom experiments were conducted to test the accuracy of needle insertion by using a transparent hydrogel phantom with a high imitation artificial phantom. Also, the efficiency was validated in this procedure by comparing time costs in manual positioning with robotic positioning under the same experimental conditions. The robotic system achieved the positioning accuracy of 0.28 ± 0.25 mm and the position repeatability of 0.09 ± 0.11 mm. Experimental results showed that the robot was CT-compatible and responded reliably to the control commands. The mean registration accuracy

  13. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  14. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    Science.gov (United States)

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  15. Needle stick injuries during fine needle aspiration procedure: Frequency, causes and knowledge, attitude and practices of cytopathologists

    Directory of Open Access Journals (Sweden)

    Neeta Kumar

    2011-01-01

    Full Text Available Background: There is no study available on the frequency, predisposing factors and outcome of needle stick injury (NSI in cytopathologists who perform fine needle aspiration (FNA. Aim: To know the frequency, circumstances and sequlae of NSI sustained by cytopathologists, assess their knowledge about risks of NSI and attitudes and practices towards use of standard precautions and post-injury wound care. Materials and Methods: Study design: cross sectional. Setting: Tertiary care teaching and non-teaching hospitals and private laboratories. Data collection method: Knowledge, attitude and practices survey using a questionnaire. Results: Majority (90.5% of the respondents have had NSI in their total career. In the previous year, more than half (71.4% had at least one NSI (mean 3.2. NSI was the most common in index finger of non-dominant hand (59.6% and occurred during step two of FNA procedure when the needle was being manipulated within the lump. The major predisposing factors were uncooperative patients (88.9%, small children (54%, deep masses (36.5%, hot humid climate (88.9%, heavy workload (76.2% and poor administrative arrangement (54%. The adherence to standard precautions was not optimal (74.6%. None of them reported NSI to the authorities, nor investigated source patient or themselves. 82.5% of the respondents were not aware of any formal exposure reporting system in their hospital. Conclusion: Cytopathologists frequently experience NSI while performing FNA. Frequency of injury is also related to patient characteristics and work site factors. Education and motivation for adhering to standard precautions and post-exposure prophylaxis are often lacking.

  16. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  17. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  18. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    Science.gov (United States)

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  19. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  20. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    Science.gov (United States)

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.