WorldWideScience

Sample records for ct-clinical experience koronarkalkquantifizierung

  1. Clinical experience of quantex coordinate software for CT guided stereotactic surgery

    International Nuclear Information System (INIS)

    Yabashi, Toshitake; Ichikawa, Hideo; Yasuda, Eisuke; Tsuruta, Hatsuo; Ishikawa, Yoshihisa; Kimura, Tokuji; Kanamori, Isao

    1991-01-01

    Recently, Quantex Coordinate Software was newly developed for CT-guided stereotactic surgery. We have the opportunity of using this software in 6 cases with intracerebral hematoma for evacuation and 2 cases with brain tumor for needle biopsy by using CT-guided stereotactic surgery. The followings are the features with a little clinical experience. One of the biggest features is that this software can simulate the best expected route of the puncture needle from burr hole to target point before inserting. Also compared with CT 9000 series Software, it has many new functions for more advanced hardware as well as advance standard software. Two cases of intracerebral hematoma for evacuation and 1 case of a brain tumor for a biopsy were carried out using this software mainly as a simulation. In all cases, this software proved to be very useful. (author)

  2. Atlas of Skeletal SPECT/CT Clinical Images

    International Nuclear Information System (INIS)

    2016-01-01

    The atlas focuses specifically on single photon emission computed tomography/computed tomography (SPECT/CT) in musculoskeletal imaging, and thus illustrates the inherent advantages of the combination of the metabolic and anatomical component in a single procedure. In addition, the atlas provides information on the usefulness of several sets of specific indications. The publication, which serves more as a training tool rather than a textbook, will help to further integrate the SPECT and CT experience in clinical practice by presenting a series of typical cases with many different patterns of SPECT/CT seen in bone scintigraphy

  3. Acute pancreatitis: clinical vs. CT findings

    International Nuclear Information System (INIS)

    Hill, M.C.; Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-01-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months

  4. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  5. Development of a CT simulator and its current clinical status

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Hiraoka, Masahiro; Nishidai, Takehiro

    2000-01-01

    A computed tomography (CT) simulator is defined as a radiotherapy treatment planning (RTP) system which consists of an X-ray CT scanner, a treatment planning computer, and a marking projector. The developmental process from the introduction of an X-ray CT to a CT simulator is described in this article. After the development of the first CT simulator, several new developments in CT scanners, marking projector, and data transfer networks were introduced. CT simulator systems have recently become more widely available and are produced by more than 8 commercial companies. The advantages of a CT simulator are a shortening of overall RTP time, increased accuracy of RTP, and the possibility of 3-D conformal therapy. Clinical experience with CT simulators has accumulated over the past 10 years. Site-specific trials have been undertaken, and the clinical usefulness of CT simulators for breast cancer, maxillary cancer, nasopharyngeal cancer, orbital tumor, lung cancer and other tumors has been demonstrated. The use of CT simulators has resulted in a decrease in the complications of radiotherapy. It also appears to be an essential tool for dose escalation studies, which may permit increased local control of certain tumors. In Japan, CT simulators were in use at more than 134 (20%) of 682 radiotherapy institutions as of the end of 1998. In the USA, CT simulators were present in more than 12% of 1,542 radiotherapy centers in 1994. The CT simulator is now an essential RTP system for advanced radiotherapy. (author)

  6. Clinical value of CT in neuropediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Reisner, Th. (Vienna Univ. (Austria). Neurologische Klinik)

    1981-11-27

    Cranial computed-tomography (CT) has opened new dimensions in neuropediatric diagnosis. The relationship between clinical symptoms and CT results is presented. 1930 patients were investigated, one group is made up of 334 newborns and infants, the other group contains children in the age between 13 months and 15 years. Newborns and infants confront the neurologist with stereotyped deficiency symptoms which nevertheless can arise from many causes. CT can make an etiological classification. In childhood illnesses of neurophyschiatric nature sometimes predominate whose clinical symptoms are often minimal (e.g. cerebral seizures, hydrocephalus, perinatal brain damage, various types of headache etc.). Here again CT can give the clinical valuable indications concerning diagnosis and therapeutic procedure.

  7. Characterizing Clinical Genetic Counselors' Countertransference Experiences: an Exploratory Study.

    Science.gov (United States)

    Reeder, Rebecca; Veach, Patricia McCarthy; MacFarlane, Ian M; LeRoy, Bonnie S

    2017-10-01

    Countertransference (CT) refers to conscious and unconscious emotions, fantasies, behaviors, perceptions, and psychological defenses genetic counselors experience in response to any aspect of genetic counseling situations (Weil 2010). Some authors theorize about the importance of recognizing and managing CT, but no studies solely aim to explore genetic counselors' experiences of the phenomenon. This study examined the extent to which clinical genetic counselors' perceive themselves as inclined to experience CT, gathered examples of CT encountered in clinical situations, and assessed their CT management strategies. An anonymous online survey, sent to NSGC members, yielded 127 usable responses. Participants completed Likert-type items rating their CT propensities; 57 of these individuals also provided examples of CT they experienced in their practice. Factor analysis of CT propensities tentatively suggested four factors: Control, Conflict Avoidance, Directiveness, and Self-Regulation, accounting for 38.5% of response variance. Thematic analysis of CT examples yielded five common triggers: general similarity to patient, medical/genetic similarity, angry patients, patient behaves differently from counselor expectations, and disclosing bad news; six common manifestations: being self-focused, projecting feelings onto the patient, intense emotional reaction to patient, being overly invested, disengagement, and physical reaction; five CT effects: disruption in rapport building, repaired empathy, over-identification, conversation does not reach fullest potential, and counselor is drained emotionally; and three management strategies: recognizing CT as it occurs, self-reflection, and consultation. Results suggest CT is a common experience, occurring in both "routine" and emotionally complex cases. Training programs, continuing education, and peer supervision might include discussion of CT, informed by examples from the present study, to increase genetic counselor awareness

  8. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  9. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  10. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  11. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  12. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  13. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  14. Clinical experience of titanium cerebral aneurysm clips. Evaluation of artifact of CT and MRI

    International Nuclear Information System (INIS)

    Ninomiya, Takashi; Kato, Yoko; Sano, Hirotoshi

    1996-01-01

    The titanium aneurysm clips manufactured by AESCULAP Company are expected to be useful, not only for clinical applications, but also for reducing artifacts in post-operative CT and MRI. We carried out an investigation of the behavior of the new Yasargil titanium clips in a 1.5T MR imager. The new titanium clips showed considerably smaller clip-induced MR and CT artifacts than phynox and elgiloy clips. No movement of the titanium clips was seen by introducing them to the MR imager. Subsequent to these experimental studies, we applied titanium clips to 25 cerebral aneurysms. Post-operative CT, especially helical scanning CT and MR showed minimal artifacts, leading to the conclusion that the titanium clips are better than the other types of clips for the evaluation of post-operative neuroradiological images. (author)

  15. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  16. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  17. The clinical value of CT in neuropediatrics

    International Nuclear Information System (INIS)

    Reisner, Th.

    1981-01-01

    Cranial computed-tomography (CT) has opened new dimensions in neuropediatric diagnosis. The relationship between clinical symptoms and CT results is presented. 1930 patients were investigated, one group is made up of 334 newborns and infants, the other group contains children in the age between 13 months and 15 years. Newborns and infants confront the neurologist with stereotyped deficiency symptoms which nevertheless can arise from many causes. CT can make an etiological classification. In childhood illnesses of neurophsychiatric nature sometimes predominate whose clinical symptoms are often minimal (e.g. cerebral seizures, hydrocephalus, perinatal brain damage, various types of headache etc.). Here again CT can give the clinical valuable indications concerning diagnosis and therapeutic procedure. (M.J.)

  18. Musculoskeletal wide detector CT: Principles, techniques and applications in clinical practice and research

    International Nuclear Information System (INIS)

    Gondim Teixeira, Pedro Augusto; Gervaise, Alban; Louis, Matthias; Lecocq, Sophie; Raymond, Ariane; Aptel, Sabine; Blum, Alain

    2015-01-01

    Highlights: • Wide area-detector CT availability is growing steadily. • Advanced techniques such as Dynamic CT, Perfusion CT and dual energy can be used in clinical practice. • Optimal acquisition protocol is needed to increase diagnostic performance and limit dose exposure. • Guidelines for data acquisition and interpretation may increase diagnostic performance and reproducibility. - Abstract: A progressive increase in the detector width in CT scanners has meant that advanced techniques such as dynamic, perfusion and dual-energy CT are now at the radiologist's disposal. Although these techniques may be important for the diagnosis of various musculoskeletal diseases, data acquisition and interpretation can be challenging. This article offers a practical guide for the use of these tools including acquisition protocol, post-processing options and data interpretation based on 7 years of clinical experience in a tertiary university hospital

  19. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  20. 'Ready-access' CT imaging for an orthopaedic trauma clinic.

    LENUS (Irish Health Repository)

    Cawley, D

    2011-03-01

    \\'Ready-Access\\' to CT imaging facilities in Orthopaedic Trauma Clinics is not a standard facility. This facility has been available at the regional trauma unit, in Merlin Park Hospital, Galway for the past four years. We reviewed the use of this facility over a 2-year period when 100 patients had CT scans as part of their trauma clinic assessment. The rate of CT scan per clinic was 0.6. The mean waiting time for a CT scan was 30 minutes. 20 (20%) new fractures were confirmed, 33 (33%) fractures were out-ruled, 25 (25%) fractures demonstrated additional information and 8 (8%) had additional fractures. 20 (20%) patients were discharged and 12 (12%) patients were admitted as a result of the CT scan. It adds little time and cost to CT scanning lists.

  1. Myocardial delayed-enhancement CT: initial experience in children and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  2. Myocardial delayed-enhancement CT: initial experience in children and young adults

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2017-01-01

    Clinical utility of myocardial delayed enhancement CT has not been reported in children and young adults. To describe initial experience of myocardial delayed enhancement CT regarding image quality, radiation dose and identification of myocardial lesions in children and young adults. Between August 2013 and November 2016, 29 consecutive children and young adults (median age 16 months) with suspected coronary artery or myocardial abnormality underwent arterial- and delayed-phase cardiac CT at our institution. We measured CT densities in normal myocardium, left ventricular cavity, and arterial and delayed hypo-enhancing and delayed hyperenhancing myocardial lesions. We then compared the extent of delayed hyperenhancing lesions with delayed-enhancement MRI or thallium single-photon emission CT. Normal myocardium and left ventricular cavity showed significantly higher CT numbers on arterial-phase CT than on delayed-phase CT (t-test, P<0.0001). Contrast-to-noise ratios of the arterial and delayed hypo-enhancing and delayed hyperenhancing lesions on CT were 26.7, 17.6 and 18.7, respectively. Delayed-phase CT findings were equivalent to those of delayed-enhancement MRI in all cases (7/7) and to those of thallium single-photon emission CT in 70% (7/10). Myocardial delayed-enhancement CT can be added to evaluate myocardial lesions in select children and young adults with suspected coronary artery or myocardial abnormality. (orig.)

  3. CT appearances of emphysema and clinical application

    International Nuclear Information System (INIS)

    Wang Xinlian; Ma Daqing; Chen Budong; He Wen; Guan Yansheng; Zhang Yansong; Tang Hongqu; Wang Zhenguang

    2006-01-01

    Objective: To investigate CT appearances of different types of emphysema and to determine the clinic value for differential diagnosis. Methods: Twenty-three specimens with emphysema selected from 33 autopsy specimens were included in this study. All specimens were inflated and fixed by Heitzman's method, then examined by spiral CT scan. The CT appearances of different types of emphysema in every specimen were analyzed. After the specimens were cut into 10 mm thickness slices, the CT- pathologic correlation was done. Fifteen clinical cases confirmed by pathology or clinical process were all performed spiral CT scan and analyzed, including emphysema-accompanying pneumonia 11 cases, emphysema-accompanying nodule 4 cases. Result: Centriacinar emphysema (CAE)can be seen in 21 of 23 specimens, pancinar emphysema(PAE) can be seen in 5 of 23 specimens, all coexisting with CAE. Distal acinar emphysema(DAE) can be seen in 19 of 23 specimens, irregular emphysema can be seen in 3 of 23 specimens. In all specimens, emphysema can be seen in bilateral lung fields, distributing similarly. Seventeen of 23 eases (17/23) showed no less than two types of emphysema. Fourteen cases of emphysema- accompanying pneumonia (clinic: 11 cases, specimen: 3 cases) showed 'pseudocavity' or 'pseudohoneycombing' (emphysema lesion that had not been filled in the consolidation). Four eases of emphysema-accompanying nodule showed 'pseudopleuralhollow' (wall of DAE or bulla connecting with nodule). Conclusion: The CT manifestations of emphysema, the characteristics of distribution and multi- type of emphysema coexisting can help differentiate cystic air space diseases. The characteristics of complications of emphysema, the 'pseudocavity', 'pseudohoneycombing' and 'pseudopleuralhollow', may be help for differential diagnosis. (authors)

  4. PET CT imaging: the Philippine experience

    International Nuclear Information System (INIS)

    Santiago, Jonas Y.

    2011-01-01

    Currently, the most discussed fusion imaging is PET CT. Fusion technology has tremendous potential in diagnostic imaging to detect numerous conditions such as tumors, Alzheimer's disease, dementia and neural disorders. The fusion of PET with CT helps in the localization of molecular abnormalities, thereby increasing diagnostic accuracy and differentiating benign or artefact lesions from malignant diseases. It uses a radiotracer called fluro deoxyglucose that gives a clear distinction between pathological and physiological uptake. Interest in this technology is increasing and additional clinical validation are likely to induce more health care providers to invest in combined scanners. It is hope that in time, a better appreciation of its advantages over conventional and traditional imaging modalities will be realized. The first PET CT facility in the country was established at the St. Luke's Medical Center in Quezon City in 2008 and has since then provided a state-of-the art imaging modality to its patients here and those from other countries. The paper will present the experiences so far gained from its operation, including the measures and steps currently taken by the facility to ensure optimum workers and patient safety. Plans and programs to further enhance the awareness of the Filipino public on this advanced imaging modality for an improved health care delivery system may also be discussed briefly. (author)

  5. Experiments on CT plasma merging in the CTCC-1

    International Nuclear Information System (INIS)

    Watanabe, K.; Ikegami, K.; Nishikawa, M.; Ozaki, A.; Satomi, N.; Uyama, T.

    1982-01-01

    A compact toroid (CT) plasma merging experiment has been tried preliminarily in the CTCC-1 experiment as a method for further-heating of CT, on producing two CT plasmas in the flux conserver successively. Two CT plasmas were observed really to merge with each other in the flux conserver. In the merging process, it is found that the field reconnection of surface magnetic field lines of CT is completed until 30 μs after the second CT injection, but magnetic field lines around the center of CT merge slowly, taking about 100 μs. Experimental results indicate that merging of CT results in doubled addition of toroidal fluxes and no-addition of poloidal fluxes

  6. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  7. Clinical PET/CT imaging. Promises and misconceptions

    International Nuclear Information System (INIS)

    Czernin, J.; Auerbach, M.A.

    2005-01-01

    PET/CT is now established as the most important imaging tool in oncology. PET/CT stages and restages cancer with a higher accuracy than PET or CT alone. The sometimes irrational approach to combine state of the art PET with the highest end CT devices should give way to a more reasonable equipment design tailored towards the specific clinical indications in well-defined patient populations. The continuing success of molecular PET/CT now depends more upon advances in molecular imaging with the introduction of targeted imaging probes for individualized therapy approaches in cancer patients and less upon technological advances of imaging equipment. (orig.)

  8. Initial experience with AcQsim CT simulator

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Gerber, Russell; Bosch, Walter R.; Harms, William; Matthews, John W.; Purdy, James A.; Perez, Carlos A.

    1995-01-01

    Purpose: We recently replaced our university developed CT simulator prototype with a commercial grade spiral CT simulator (Picker AcQsim) that is networked with three independent virtual simulation workstations and our 3D radiation therapy planning (3D-RTP) system multiple workstations. This presentation will report our initial experience with this CT simulation device and define criteria for optimum clinical use as well as describe some potential drawbacks of the current system. Methods and Materials: Over a 10 month period, 210 patients underwent CT simulation using the AcQsim. An additional 127 patients had a volumetric CT scan done on the device with their CT data and target and normal tissue contours ultimately transferred to our 3D-RTP system. We currently perform the initial patient localization and immobilization in the CT simulation suite by using CT topograms and a fiducial laser marking system. Immobilization devices, required for all patients undergoing CT simulation, are constructed and registered to a device that defines the treatment table coordinates. Orthogonal anterior and lateral CT topograms document patient alignment and the position of a reference coordinate center. The volumetric CT scan with appropriate CT contrast materials administered is obtained while the patient is in the immobilization device. On average, more than 100 CT slices are obtained per study. Contours defining tumor, target, and normal tissues are drawn on a slice by slice basis. Isocenter definition can be automatically defined within the target volume and marked on the patient and immobilization device before leaving the initial CT simulation session. Virtual simulation is then performed on the patient data set with the assistance of predefined target volumes and normal tissue contours displayed on rapidly computed digital reconstructed radiographs (DRRs) in a manner similar to a conventional fluoroscopic radiotherapy simulator. Lastly, a verification simulation is

  9. Clinical PET/CT Atlas: A Casebook of Imaging in Oncology

    International Nuclear Information System (INIS)

    2015-01-01

    Integrated positron emission tomography/computed tomography (PET/CT) has evolved since its introduction into the commercial market more than a decade ago. It is now a key procedure, particularly in oncological imaging. Over the last years in routine clinical service, PET/CT has had a significant impact on diagnosis, treatment planning, staging, therapy, and monitoring of treatment response and has therefore played an important role in the care of cancer patients. The high sensitivity from the PET component and the specificity of the CT component give this hybrid imaging modality the unique characteristics that make PET/CT, even after over 10 years of clinical use, one of the fastest growing imaging modalities worldwide. This publication combines over 90 comprehensive cases covering all major indications of fluorodeoxyglucose (18F-FDG)-PET/CT as well as some cases of clinically relevant special tracers. The cases provide an overview of what the specific disease can look like in PET/CT, the typical pattern of the disease’s spread as well as likely pitfalls and teaching points. This PET/CT Atlas will allow professionals interested in PET/CT imaging to embrace the variety of oncological imaging by providing clinically relevant teaching files on the effectiveness and diagnostic quality of FDG-PET/CT imaging in routine applications

  10. Clinical applications of SPECT/CT: advantages and limitations

    International Nuclear Information System (INIS)

    Rigo, P.

    2006-01-01

    The application of hybrid SPECT cameras in Nuclear Medicine follows the revolutionary introduction of PET/CT. This review focuses on the advantages and limitations of SPECT/CT in its various clinical indications. It appears that SPECT/CT will be a clear factor of progress for Nuclear Medicine. (author)

  11. Clinical and CT analysis of GCS 15 patients with intracranial hemorrhage

    International Nuclear Information System (INIS)

    Yang Lin; He Jianyuan; Jiang Shanyue; Zhang Yanling

    2007-01-01

    Objective: To analyze the clinical symptoms and CT manifestations of GCS 15 patients with intracranial hemorrhage. Methods: Clinical data and manifestations of the CT images of 35 patients with GCS 15 and intracranial hemorrhage were retrospectively analyzed and followed up. in short term. Results: Clinical symptoms: Deficits in short-term memory appeared in 17% of patients, vomiting in 26%, headache in 97%, physical evidence of trauma above the clavicles in 100%. CT scanning: intracerebral hemorrhage occurred in 18 patients, epidural hemorrhage in 9 patients, subarachnoid hemorrhage in 8 patients, subdural hemorrhage in 7 patients. During follow up, clinical severe degree was in consistent of craniocerebral CT scanning. Conclusion: For patients with GCS 15 brain injuries early head CT scanning is very important. Intracranial hemorrhage may occur in these patients. If possible, re-assessment of clinical examination and CT scanning is remarkably necessary. (authors)

  12. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    Science.gov (United States)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  13. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  14. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  15. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  16. Cardiac 82rubidium PET/CT: initial European experience

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Dickson, John C.; Kayani, Irfan; Endozo, Raymondo; Blanchard, Patty; Shastry, Manu; Prvulovich, Elizabeth; Waddington, Wendy A.; Ben-Haim, Simona; Bomanji, Jamshed B.; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean R.

    2007-01-01

    Myocardial perfusion with PET/CT has advantages over conventional SPECT. We describe our initial European experience using 82 Rubidium-PET/CT, as part of a clinical myocardial perfusion service. We studied the first 100 patients (64 male; 36 female, mean age = 60: SD +/-12.5y, mean body mass index = 30: SD +/-6.9kg/m 2 ) who underwent 82 Rubidium cardiac PET/CT in our institution. Thirty patients had recently undergone coronary angiography. Patients underwent imaging during adenosine infusion and at rest. Images were acquired over 5 minutes using a GE-PET/CT instrument. Image quality was described as good, adequate or inadequate. Images were reported patient-by-patient by a minimum of five nuclear medicine physicians. A segment-by-segment analysis (17-segment model) was also performed. Image quality was good in 77%, adequate 23% and inadequate 0%. There was no statistical difference in image quality between obese and non-obese patients (Fisher's exact test, p = 0.2864). 59% had normal perfusion studies, 29% had inducible ischaemia, 12% had myocardial infarction (11% with super added ischaemia). There was reduced 82 Rubidium uptake in 132/1700 segments during stress. There was reduced 82 Rubidium uptake at rest in 42/1700 segments. The 82 Rubidium PET/CT findings were consistent with the angiographic findings in 28/30 cases. We show that, even from initial use of 82 Rubidium, it is possible to perform myocardial perfusion studies quickly with good image quality, even in the obese. The PET findings correlated well in the third of the cases where angiography was available. As such, 82 Rubidium cardiac PET/CT is likely to be an exciting addition to the European nuclear physician/ cardiologist's radionuclide imaging arsenal. (orig.)

  17. Clinically relevant incidental cardiovascular findings in CT examinations

    International Nuclear Information System (INIS)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A.; Schramm, D.; Bach, A.G.

    2017-01-01

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [de

  18. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  19. Value and clinical application of orthopedic metal artifact reduction algorithm in CT scans after orthopedic metal implantation

    International Nuclear Information System (INIS)

    Hu, Yi; Pan, Shinong; Zhao, Xudong; Guo, Wenli; He, Ming; Guo, Qiyong

    2017-01-01

    To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants

  20. Clinical menifestations and CT findings of lacunar infarction

    International Nuclear Information System (INIS)

    Shimada, Tsutomu; Kaneko, Mitsuo; Tanaka, Keisei; Sato, Kengo; Yamamoto, Toshiki

    1983-01-01

    Since the introduction of the CT scanner, the present authors have experienced 111 cases of lacunar infarction which were diagnosed on the basis of clinical manifestations and/or CT findings, being 35 % of total 318 cases of acute cerebral infarction in our series. The clinical features and their correlation with the CT findings were studied in the cases of lacunar infarction. The results were as follows. 1) Seventy-four per cent of the patients were hypertensive. 2) Fifty per cent of the patients had only motor deficit. 3) The patients who revealed small deep infarctions in the posterior two-thirds of the posterior limb of the internal capsule on CT scan had more marked motor impariment with more involvement of the upper extremity than the lower extremity. 4) The recovery of the motor deficit was generally good, but unsatisfactory when the patient had a larger lesion than 10 mm in diameter. (author)

  1. Clinically relevant incidental cardiovascular findings in CT examinations; Klinisch relevante kardiovaskulaere Zufallsbefunde bei CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A. [Universitaetsklinikum Leipzig, Klinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Schramm, D.; Bach, A.G. [Universitaetsklinikum Halle (Saale), Klinik fuer Radiologie, Halle (Germany)

    2017-04-15

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [German] Inzidentelle kardiovaskulaere Befunde sind ein haeufiges Phaenomen bei CT-Untersuchungen. Mit dieser Arbeit soll nach gezielter PubMed-Recherche ein systematischer Literaturueberblick ueber die wichtigsten kardiovaskulaeren Zufallsbefunde sowie deren Haeufigkeit und klinische Relevanz gegeben werden. Die Mehrzahl der inzidentellen kardiovaskulaeren Befunde sind klinisch nur von untergeordneter Bedeutung, allerdings werden immer wieder auch hochgradig relevante Zufallsbefunde wie beispielsweise Aortenaneurysmata oder - gerade bei onkologischen Patienten - Thrombosen und thrombembolische Ereignisse detektiert. Jede CT-Untersuchung sollte gezielt nach inzidentellen Befunden durchsucht werden, da diese je nach klinischer Relevanz von entscheidender Bedeutung fuer das weitere klinische Management des Patienten sein koennen. (orig.)

  2. Clinical and CT scan pictures of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Singounas, E.G.; Krassanakis, K.; Karvounis, P.C. (Evangelismos Hospital, Athens (Greece))

    1982-01-01

    The clinical presentations and CT scan pictures of four patients harbouring big cysticercus cysts are described. The value of CT scanning in detecting these cysts is emphasized, and also the fact that these cysts can behave as space-occyping lesions, which must be differentiated from other cystic formations.

  3. The clinical importance of expanded subarachnoid spaces detected by CT in early infancy

    International Nuclear Information System (INIS)

    Krusche, S.

    1982-01-01

    It depends on the clinical course and on follow-jup CT findings whether expansions of the subarachnoid space should be considered as pathological changes or as normal. There is no direct correlation between the degree of severity of the clinical symptoms on the one hand and the CT changes on the other. The clinical course and the follow-up CT images are found to be uncorrelated, too. CT findings alone are insufficient in predicting children's development. Especially in the case of unspecific changes, e.g. slight expansions of the subarachnoid space, cranial CT can only provide further proof of a suspected clinical diagnosis. The ventricular indices frequently used for CT interpretation can rarely be used as decision aids or as factors providing new information. (orig./MG) [de

  4. Value and clinical application of orthopedic metal artifact reduction algorithm in CT scans after orthopedic metal implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yi; Pan, Shinong; Zhao, Xudong; Guo, Wenli; He, Ming; Guo, Qiyong [Shengjing Hospital of China Medical University, Shenyang (China)

    2017-06-15

    To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants.

  5. Initial clinical experience with spiral CT angiography in the abdomen

    International Nuclear Information System (INIS)

    Gaa, J.; Stehling, M.K.; Costello, P.

    1993-01-01

    The latest developments in modern CT instruments, offering scanning times of a second, opened up new possibilities in CT imaging in combination with the spiral technique. The data set normally taken with single-breath-hold technique is free of respiratory artefacts and thus is a good basis for accurate 3D image reconstruction. Spiral CTA allows a non-invasive 3D imaging of various blood vessels. Patients with abdominal aortic aneurysms of aorto-iliac bypass can be examined as outpatients within 15 minutes. (orig.) [de

  6. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  7. Performance of FDG PET/CT in the clinical management of breast cancer.

    Science.gov (United States)

    Groheux, David; Espié, Marc; Giacchetti, Sylvie; Hindié, Elif

    2013-02-01

    In this analysis, the role of metabolic imaging with fluorine 18 fluorodeoxyglucose (FDG) in breast cancer is reviewed. The analysis was limited to recent works by using state-of-the-art positron emission tomography (PET)/computed tomography (CT) technology. The strengths and limitations of FDG PET/CT are examined in various clinical settings, and the following questions are answered: Is FDG PET/CT useful to differentiate malignant from benign breast lesions? Can FDG PET/CT replace sentinel node biopsy for axillary staging? What is the role of FDG PET/CT in initial staging of inflammatory or locally advanced breast cancer? What is the role of FDG PET/CT in initial staging of clinical stage IIA and IIB and primary operable stage IIIA breast cancer? How does FDG PET/CT compare with conventional techniques in the restaging of cancer in patients who are suspected of having disease recurrence? What is the role of FDG PET/CT in the assessment of early response to neoadjuvant therapy and of response to therapy for metastatic disease? Some recommendations for clinical practice are given.

  8. Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions

    International Nuclear Information System (INIS)

    Fin, Loic; Daouk, Joel; Morvan, Julie; Esper, Isabelle El; Saidi, Lazhar; Meyer, Marc-Etienne; Bailly, Pascal

    2008-01-01

    Respiratory motion causes uptake in positron emission tomography (PET) images of chest structures to spread out and misregister with the CT images. This misregistration can alter the attenuation correction and thus the quantisation of PET images. In this paper, we present the first clinical results for a respiratory-gated PET (RG-PET) processing method based on a single breath-hold CT (BH-CT) acquisition, which seeks to improve diagnostic accuracy via better PET-to-CT co-registration. We refer to this method as ''CT-based'' RG-PET processing. Thirteen lesions were studied. Patients underwent a standard clinical PET protocol and then the CT-based protocol, which consists of a 10-min List Mode RG-PET acquisition, followed by a shallow end-expiration BH-CT. The respective performances of the CT-based and clinical PET methods were evaluated by comparing the distances between the lesions' centroids on PET and CT images. SUV MAX and volume variations were also investigated. The CT-based method showed significantly lower (p=0.027) centroid distances (mean change relative to the clinical method =-49%; range =-100% to 0%). This led to higher SUV MAX (mean change =+33%; range =-4% to 69%). Lesion volumes were significantly lower (p=0.022) in CT-based PET volumes (mean change =-39%: range =-74% to -1%) compared with clinical ones. A CT-based RG-PET processing method can be implemented in clinical practice with a small increase in radiation exposure. It improves PET-CT co-registration of lung lesions and should lead to more accurate attenuation correction and thus SUV measurement. (orig.)

  9. Invasive pulmonary aspergillosis - CT findings in context with the clinical course

    International Nuclear Information System (INIS)

    Seyfarth, H.J.; Winkler, J.; Wirtz, H.; Nenoff, P.; Krahl, R.; Kloeppel, R.; Borte, G.

    2002-01-01

    Purpose: To investigate the impact of chest radiographs and CT in patients suffering from invasive pulmonary aspergillosis (IPA) compared to the clinical course. Patients and Methods: Twenty-three patients with confirmed diagnosis of IPA between January 1996 and September 1999 were included in this study. Signs of inflammatory infiltrates on chest radiographs and CT were retrospectively evaluated in relation to the onset of the clinical symptoms. Infiltrates on CT were analyzed in detail with respect to number, morphology, and localization. Results: Seventy-six infiltrates were found on the CT of 22 patients; one patient had diffuse areas of lung infiltrates. Both lungs were affected by infiltrates in 14 patients. Pleural effusions were confirmed in 12 patients. Twelve patients had typically round foci with halo and nine patients crescent air signs. The preferred localization of lung infiltrates was segment 6. The median interval between the onset of clinical symptoms and the first radiographic changes was 5.5 days, with an additional interval of 4.5 days until confirmation by CT. Localization, number of infiltrates, and clinical course were not related. Conclusion: In immune-compromised patients with fever, a CT of the chest should be carried out as soon as possible to detect signs indicative of IPA. Morphological changes on CT like a round focus with halo and crescent air sign support the diagnosis of IPA. In this context, special attention should be directed to pulmonary segment 6. (orig.) [de

  10. Degenerative osteoarthritis of atlanto-odontoid joint: CT findings and clinical analysis

    International Nuclear Information System (INIS)

    Xu Aide; Wang Song; Mao Yunhua

    1998-01-01

    Purpose: To analyze the CT appearances and clinical aspects of the degeneration at atlanto-odontoid(A-O) joint. Methods: Thin section axial CT scans, of AO joints were studied in 317 consecutive patients who underwent brain or cervical spine CT examinations. The images were viewed using double-blind method. Observation included: osteophytosis, changes of joint space and transverse ligament, and the clinical symptoms as well. Results: CT findings of AO joint degeneration included: formation of osteophyte, narrowing of joint space, transverse ligament calcification, and joint vacuum phenomenon. Among individuals above 40 years of age, the incidence of degeneration at AO joint went up gradually (P<0.01). Conclusion: Degeneration of AO joint was not uncommon among aged people, CT could better demonstrate the pathological changes

  11. Head injury: audit of a clinical guideline to justify head CT

    International Nuclear Information System (INIS)

    Haydon, Nicholas B.

    2013-01-01

    Head injury causes significant morbidity and mortality, and there is contention about which patients to scan. The UK National Health Service Clinical Guideline (CG) 56 provides criteria for selecting patients with clinically important brain injury who may benefit from a head CT scan, while minimising the radiation and economic burden of scanning patients without significant injury. This study aims to audit the documentation of the use of these guidelines in a busy UK trauma hospital and discusses the comparison with an Australian (New South Wales (NSW) ) head injury guideline. A retrospective cohort study of 480 patients presenting with head injury to the emergency department over 2 months was performed. The patient notes were assessed for documentation of each aspect of the clinical guidelines. Criteria were established to assess the utilisation of the CG 56. A database of clinical data was amalgamated with the head CT scan results for each patient. For the UK CG 56, 73% of the criteria were documented, with the least documented being 'signs of basal skull fracture' and 'amnesia of events'. Thirty-two per cent of patients received head CT and of these, 24% (37 patients) were reported to have pathology. Twenty-four patients underwent head CT without clinical justification being documented, none of which had reported pathology on CT. The study shows that the head injury guidelines are not being fully utilised at a major UK trauma hospital, resulting in 5% of patients being exposed to ionising radiation without apparent documented clinical justification. The NSW guideline has distinct differences to the CG 56, with a more complex algorithm and an absence of specific time frames for head CT completion. The results suggest a need for further education and awareness of head injury clinical guidelines.

  12. Pneumatosis intestinalis: CT findings and clinical features

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Lin; Lee, Hae Kyung; Park, Seong Jin; Yi, Boem Ha; Ko, Bong Min; Hong, Hyun Sook; Paik, Sang Hyun [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of)

    2008-02-15

    The purpose of this study is to evaluate the CT findings and clinical features of patients with pneumatosis intestinalis. From January 2001 to October 2007, 15 patients with pneumatosis intestinalis were diagnosed by the use of CT. We analyzed the clinical features and CT findings to assess the involvement site, the presence of portal and mesenteric vein gas, and the existence of accompanied ischemic change. Of the 15 patients, five patients had end stage renal disease (33.3%), two patients underwent a gastrectomy, one patient underwent a laminectomy, one patient had tuberculous enteritis, one patient had lung cancer and one patient had pneumonia. Four patients presented with no specific disease. There was portal or mesenteric venous gas in six cases, and strangulation or an ischemic change of the bowel in five cases. Otherwise, pneumatosis intestinalis was associated with hydropneumoperitoneum in two cases, pneumoperitoneum in one case and a single case of perforated appendicitis. Nine patients underwent surgery for ischemic change of the bowel, pneumoperitoneum, appendicitis, and a clinical sign of panperitonitis. Among the remaining six patients, three patients recovered and were discharged, and three patients expired during progression of the disease. End stage renal disease is the most common condition associated with pneumatosis intestinalis. The presence of portomesenteric venous gas, ischemic change of the bowel, and linear pneumatosis intestinalis are indicative of a poor prognosis.

  13. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  14. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  15. Iterative Reconstruction Techniques in Abdominopelvic CT: Technical Concepts and Clinical Implementation.

    Science.gov (United States)

    Patino, Manuel; Fuentes, Jorge M; Singh, Sarabjeet; Hahn, Peter F; Sahani, Dushyant V

    2015-07-01

    This article discusses the clinical challenge of low-radiation-dose examinations, the commonly used approaches for dose optimization, and their effect on image quality. We emphasize practical aspects of the different iterative reconstruction techniques, along with their benefits, pitfalls, and clinical implementation. The widespread use of CT has raised concerns about potential radiation risks, motivating diverse strategies to reduce the radiation dose associated with CT. CT manufacturers have developed alternative reconstruction algorithms intended to improve image quality on dose-optimized CT studies, mainly through noise and artifact reduction. Iterative reconstruction techniques take unique approaches to noise reduction and provide distinct strength levels or settings.

  16. Spontaneous pneumomediastinum on CT : related condition and its clinical significance

    International Nuclear Information System (INIS)

    Kim, Sung Hyun; Im, Jung Gi; Seo, Joon Beom; Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung

    1998-01-01

    The purpose of this paper is to tabulate underlying disease and to assess the clinical significance of CT-diagnosed spontaneous pneumomediastinum. We retrospectively reviewed CT scans and medical records of 11 consecutive patients with spontaneous pneumomediastinum, and analyzed their clinical history and course, and in five cases, pulmonary function. CT scans of 126 patients with idiopathic pulmonary fibrosis (IPE) collected while the 11 consecutive patients were being treated were analyzed for the prevalence of pneumomediastinum. We analyzed CT findings with respect to the amount and distribution of air in the mediastinum, and the presence of absence of air outside the mediastinum. Spontaneous pneumomediastinum might be associated with idiopathic pulmonary fibrosis and might be a poor prognostic factor in patients with IPE or BOOP. (author). 18 refs., 2 figs

  17. Spontaneous pneumomediastinum on CT : related condition and its clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hyun; Im, Jung Gi; Seo, Joon Beom; Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung [Seoul National Univ. (Korea, Republic of). Coll. of Medicine

    1998-03-01

    The purpose of this paper is to tabulate underlying disease and to assess the clinical significance of CT-diagnosed spontaneous pneumomediastinum. We retrospectively reviewed CT scans and medical records of 11 consecutive patients with spontaneous pneumomediastinum, and analyzed their clinical history and course, and in five cases, pulmonary function. CT scans of 126 patients with idiopathic pulmonary fibrosis (IPE) collected while the 11 consecutive patients were being treated were analyzed for the prevalence of pneumomediastinum. We analyzed CT findings with respect to the amount and distribution of air in the mediastinum, and the presence of absence of air outside the mediastinum. Spontaneous pneumomediastinum might be associated with idiopathic pulmonary fibrosis and might be a poor prognostic factor in patients with IPE or BOOP. (author). 18 refs., 2 figs.

  18. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  19. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  20. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  1. The role of hybrid SPECT-CT in oncology: current and emerging clinical applications

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Scarsbrook, A.F.

    2008-01-01

    Single photon emission computed tomography - computed tomography (SPECT-CT) is an emerging dual-modality imaging technique with many established and potential clinical applications in the field of oncology. To date, there has been a considerable emphasis on the benefits of integrated positron emission tomography - computed tomography (PET-CT) in oncology, but relatively little focus on the clinical utility of SPECT-CT. As with PET-CT, accurate co-registration of anatomical and functional data from a combined SPECT-CT camera often provides complementary diagnostic information. Both sensitivity (superior disease localization) and specificity (exclusion of false-positives due to physiological tracer uptake) are improved, and the functional significance of indeterminate lesions detected on cross-sectional imaging can be defined. This article will review the scope of hybrid SPECT-CT in oncology and illustrate both current and emerging clinical applications

  2. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of)

    1994-11-15

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings.

  3. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    International Nuclear Information System (INIS)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung

    1994-01-01

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings

  4. Clinical and CT features in cases of spinocerebellar degeneration occurring at infancy

    International Nuclear Information System (INIS)

    Eda, Isematsu; Nakano, Chizuko; Kawahara, Hitoshi; Takeshita, Kenzo

    1985-01-01

    Clinical symptoms and CT findings were evaluated in 7 patients in whom symptoms compatible with spinocerebellar degeneration had occurred at infancy. CT findings included atrophy of the vermis, hemisphere and brain-stem, and dilation of the forth ventricle. These were in accordance with those reported in adult cases of spinocerebellar degeneration. There was some correlation between the severity of clinical symptoms and CT findings. Clinical lesions tended to coincide with CT findings. None of the patients had typical adult types such as delayed cerebello-cortical atrophy and olivo-pontocerebellar atrophy. There were great differences in clinical symptoms among the patients. Many of the patients had complications such as pigmentary degeneration of the retina, optic atrophy and cataract, which are rare in adult cases. It is therefore considered impossible to categorize these cases, except for two cases of familial convulsive paraplegia, as a given type. (Namekawa, K.)

  5. CT and MR imaging acquisition performance in a neuroradiology PACS module 1-year clinical experience

    International Nuclear Information System (INIS)

    Lou, S.L.; Loloyan, M.; Weinberg, W.S.; Valentino, D.J.; Lufkin, R.B.; Hanafee, W.N.; Bentson, J.; Jabour, B.A.; Huang, H.K.

    1990-01-01

    This paper analyzes the operational efficiency of our neuroradiology PACS compared with conventional film-based management systems. The authors neuroradiology PACS module has been in clinical evaluation for 6 months. Three SUN microcomputers, two PC/ATs, and an automated optical disk library are connected through Ethernet. Software implemented at the TCP/IP level is used to transfer images from MR imagers and CT scanners to a viewing station. Performance measurements include the time elapsed at each stage of the system

  6. CT-TRX1, a triggered-reconnection compact toroid experiment

    International Nuclear Information System (INIS)

    Hoffman, A.L.

    1980-05-01

    A new compact toroid experiment, CT-TRX1, based on the field reversed theta pinch is under construction. The unique feature of this experiment is the incorporation of several quasi-steady and pulsed magnets to carefully control the reconnection process. The motivation for this emphasis is to duplicate and extend the results reported by Kurtmullaev, et al., where delayed reconnection produced efficient axial shock heating and resulted in large diameter compact toroids which exhibited complete MHD stability for the 100 μsec decay time of their pulsed magnets. CT-TRX1 incorporates moderate E/sub theta/ radial shock heating, along with the triggered reconnection capability, to investigate the full range of conditions between the USSR experiments and the radial shock heated experiments at LASL, where m = 2 rotational instabilities occur. An additional feature of CT-TRX1 is the incorporation of a compound magnet which will provide long magnetic field decay times. The requirements for both high field quasi-steady outer magnets, and several high voltage, individually triggered pulsed inner magnets, present unique engineering design problems which are discussed

  7. Necrotizing pneumonia: CT findings and its clinical significance

    International Nuclear Information System (INIS)

    Park, Hong Suk; Im, Jung Gi; Ryoo, Jae Wook; Yeon, Kyung Mo; Han, Man Chung

    1995-01-01

    To analyze CT and follow-up chest radiographic findings in patients with necrotizing pneumonia and to evaluate clinical significance of the extent of necrosis. We reviewed medical records and retrospectively analysed CT scans and follow-up chest radiographs of 22 patients with necrotizing pneumonia, confirmed by biopsy (n = 7) and culture (n = 15). Inclusion criteria for necrotizing pneumonia was necrotic low attenuation, with or without cavitation on postcontrast enhanced CT scan. The study group included 15 men and seven women, aged 11-66 years (average: 47 years). The pathogens of necrotizing pneumonia were Klebsiella spp (n = 7), Enterobacter spp (n = 5), Actinomyces spp (n = 4), Pseudomonas spp (n = 4), Nocardia spp (n = 4), and others (n = 5). Average duration of pneumonia was 4.1 months. On CT scan, pneumonic consolidations were well-marginated in 14 patients and there were cavities on initial CT scan in 16 cases. Margins of the necrotic portion on CT scan were well-demarcated in majority of the patients (16/22). Low attenuation areas on initial CT scan resulted in cavitation, fibrosis and volume loss as shown on follow-up chest radiographs. The larger the necrotic areas on CT, the more the volume loss was. CT findings of necrotizing pneumonia were well-marginated air-space consolidation with low attenuation area, with or without cavity. The extent of necrotic area was closely related with the degree of fibrotic change later on. CT is important tool for diagnosis and prediction of parenchymal damage in necrotizing pneumonia

  8. Complications of CT guided lumbar sympathicolysis: own experience and review of literature

    International Nuclear Information System (INIS)

    Ernst, S.; Heindel, W.; Fischbach, R.; Langen, H.J.; Krahe, T.; Gawenda, M.; Neubauer, S.

    1998-01-01

    Aim: To review the complications of CT guided lumbar sympathicolysis (CTLS) on the basis of our own experience and the available literature. Methods: 241 CTLS were performed by a standard technique according to Haaga's method. Clinical follow-up revealed 4 serious complications; these were analysed and compared with published cases. Results: Amongst our patients there were three fibrotic ureter stenoses and one retroperitoneal abscess. Analysis of the serious complications described in the literature indicates that introduction of CT guided lumbar sympathicolysis has reduced the severity and frequency of complications as compared with surgical and 'blind' procedures. With CTLS, no deaths due to the procedure have been reported in the literature. The results indicate that damage to the ureters can be caused by substances used for the neurolysis. (orig./MG) [de

  9. Nonconcordance between Clinical and Head CT Findings: The Specter of Overdiagnosis

    Directory of Open Access Journals (Sweden)

    Kelli N. O'Laughlin

    2013-01-01

    Full Text Available Background. It is unclear whether history and physical examination findings can predict abnormalities on head computed tomography (CT believed to indicate increased risk of lumbar-puncture- (LP- induced brain herniation. The objectives of this study were to (1 identify head CT findings felt to be associated with increased risk of brain herniation and (2 to assess the ability of history and physical examination to predict those findings. Methods. Using a modified Delphi survey technique, an expert panel defined CT abnormalities felt to predict increased risk of LP-induced brain herniation. Presence of such findings on CT was compared with history and physical examination (H&P variables in 47 patients. Results. No H&P variable predicted “high-risk” CT; combining H&P variables to improve sensitivity led to extremely low specificity and still failed to identify all patients with high-risk CT. Conclusions. “High-risk” CT is not uncommon in patients with clinical characteristics known to predict an absence of actual risk from LP, and thus it may not be clinically relevant. “Overdiagnosis” will be increasingly problematic as technological advances identify increasingly subtle deviations from “normal.”

  10. CT features and clinical of diffuse axonal injury (with report of 41 cases)

    International Nuclear Information System (INIS)

    Zhang Yixing

    2005-01-01

    Objective: To evaluate CT imaging in the diagnosis of diffuse axonal injury (DAI) in correlation with the clinical manifestations. Methods: CT images and clinical data of 41 DAI cases were reviewed retrospectively, including 30 males and 11 females, 15 to 67 years old (average age was 30.5 years). According to the clinical features, all cases were classified into three groups: mild, moderate and severe injury. Results: In 10 cases of mild injury, the major CT findings were cerebral edema, slight cerebral hemorrhage in unilateral hemisphere or sub-arachnoid hemorrhage. Another 15 cases were classified as moderate injury: diffuse cerebral edema and hemorrhage in central brain gray matter were found on CT images. 16 cases with severe injury: severe diffuse cerebral edema accompanied with hemorrhage along the white-gray matter junction as well as epidural hematoma and/or subdural hematoma was demonstrated on CT images. Conclusion: CT scan is valuable in diagnosis of DAI and the anticipation of prognosis. (authors)

  11. Radiation risk and protection of patients in clinical SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Borowski, Markus [Klinikum Braunschweig, Institute of Radiation Diagnostics and Nuclear Medicine, Braunschweig (Germany)

    2014-05-15

    Clinical studies have demonstrated that hybrid single photon emission computed tomography (SPECT)/CT for various diagnostic issues has an added value as compared to SPECT alone. However, the combined acquisition of functional and anatomical images can substantially increase radiation exposure to patients, in particular when using a hybrid system with diagnostic CT capabilities. It is, therefore, essential to carefully balance the diagnostic needs and radiation protection requirements. To this end, the evidence on health effects induced by ionizing radiation is outlined. In addition, the essential concepts for estimating radiation doses and lifetime attributable cancer risks associated with SPECT/CT examinations are presented taking into account both the new recommendations of the International Commission on Radiological Protection (ICRP) as well as the most recent radiation risk models. Representative values of effective dose and lifetime attributable risk are reported for ten frequently used SPECT radiopharmaceuticals and five fully diagnostic partial-body CT examinations. A diagnostic CT scan acquired as part of a combined SPECT/CT examination contributes considerably to, and for some applications even dominates, the total patient exposure. For the common SPECT and CT examinations considered in this study, the lifetime attributable risk of developing a radiation-related cancer is less than 0.27 %/0.37 % for men/women older than 16 years, respectively, and decreases markedly with increasing age at exposure. Since there is no clinical indication for a SPECT/CT examination unless an emission scan has been indicated, the issue on justification comes down to the question of whether it is necessary to additionally acquire a low-dose CT for attenuation correction and anatomical localization of tracer uptake or even a fully diagnostic CT. In any case, SPECT/CT studies have to be optimized, e.g. by adapting dose reduction measures from state-of-the-art CT practice, and

  12. CT of the external auditory canal: Correlation with clinical otoscopy

    International Nuclear Information System (INIS)

    Shankar, L.; Hawke, M.; Leekam, R.N.

    1987-01-01

    CT is the modality of choice in the assessment of external auditory canal abnormalities. Disorders of the complex structures within the ear that may be difficult to define clinically are well visualized on high-resolution CT. This exhibit illustrates various external auditory canal abnormalities and correlates these with color illustrations from clinical otoscopy. Congenital lesions of the external auditory canal - microtia, temporo-bandibular joint herniation, and fistulas - and various acquired lesions - traumatic, inflammatory, and neoplastic - are reviewed in this exhibit

  13. CT colonography: effect of experience and training on reader performance

    International Nuclear Information System (INIS)

    Taylor, Stuart A.; Burling, David; Morley, Simon; Bartram, Clive I.; Halligan, Steve; Bassett, Paul; Atkin, Wendy

    2004-01-01

    The purpose of this paper was to investigate the effect of radiologist experience and increasing exposure to CT colonography on reader performance. Three radiologists of differing general experience (consultant, research fellow, trainee) independently analysed 100 CT colonographic datasets. Readers had no prior experience of CT colonography and received feedback and training after the first 50 cases from an independent experienced radiologist. Diagnostic performance and reporting times were compared for the first and second 50 datasets and compared with the results of a radiologist experienced in CT colonography. Before training only the consultant reader achieved statistical equivalence with the reference standard for detection of larger polyps. After training, detection rates ranged between 25 and 58% for larger polyps. Only the trainee significantly improved after training (P=0.007), with performance of other readers unchanged or even worse. Reporting times following training were reduced significantly for the consultant and fellow (P<0.001 and P=0.03, respectively), but increased for the trainee (P<0.001). In comparison to the consultant reader, the odds of detection of larger polyps was 0.36 (CI 0.16, 0.82) for the fellow and 0.36 (CI 0.14, 0.91) for the trainee. There is considerable variation in the ability to report CT colonography. Prior experience in gastrointestinal radiology is a distinct advantage. Competence cannot be assumed even after directed training via a database of 50 cases. (orig.)

  14. CT and MR imaging of the liver. Clinical importance of nutritional status

    International Nuclear Information System (INIS)

    Leander, P.; Sjoeberg, S.; Hoeglund, P.

    2000-01-01

    Purpose: In an experimental study in rats a correlation between nutritional status and hepatic attenuation in CT and signal intensities in MR imaging was shown. Is physiological nutritional status of importance in clinical CT and MR imaging? Material and methods: In a cross-over study including 12 healthy volunteers (6 women and 6 men, mean age 34 years), CT and MR imaging of the liver were performed with nutritional status at three different levels, i.e., normal, fasting and after glycogen-rich meals. CT and MR were performed on clinical imaging systems and hepatic attenuation and signal intensity, respectively, were assessed. In MR, T1-weighted, proton density-weighted and T2-weighted pulse-sequences were used. Results: In CT there were significantly (p<0.01) higher liver attenuations in normal nutritional status and after glycogen rich-meals compared to the fasting condition. The difference between fasting and glycogen-rich meals were 10.5 HU for men, 7.4 for women and mean 8.8 HU for all 12 volunteers. In MR imaging the differences were small and non-significant. The results of this study are in accordance with an earlier experimental study in rats. Conclusion: In CT it may be of importance not to have patients in a fasting condition as it lowers the attenuation in normal liver tissue. The findings are important for planning of clinical studies where hepatic attenuation will be assessed and may be of some importance in clinical CT. In MR imaging the results indicate that the nutritional status is of less importance

  15. Generating Evidence for Clinical Benefit of PET/CT in Diagnosing Cancer Patients

    DEFF Research Database (Denmark)

    Vach, Werner; Høilund-Carlsen, Poul Flemming; Gerke, Oke

    2011-01-01

    For diagnostic methods such as PET/CT, not only diagnostic accuracy but also clinical benefit must be demonstrated. However, there is a lack of consensus about how to approach this task. Here we consider 6 clinical scenarios to review some basic approaches to demonstrating the clinical benefit...... of PET/CT in cancer patients: replacement of an invasive procedure, improved accuracy of initial diagnosis, improved accuracy of staging for curative versus palliative treatment, improved accuracy of staging for radiation versus chemotherapy, response evaluation, and acceleration of clinical decisions....... We also develop some guidelines for the evaluation of clinical benefit. First, it should be clarified whether there is a direct benefit of the use of PET/CT or an indirect benefit because of improved diagnostic accuracy. If there is an indirect benefit, then decision modeling should be used initially...

  16. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  17. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  18. Studies on diagnosis of lung emphysema by CT image using experimental models and clinical cases

    International Nuclear Information System (INIS)

    Nakatani, Seiki

    1998-01-01

    Since the detailed report between the degree of functional disorder in lung emphysema and the analysis of CT image is quite unknown, the present study was attempted to produce the experimental model of lung emphysema with various stages by the administration of papain to the focal lobe in canine lung. Using this model or clinical lung emphysema, the relationship between the degree of destruction of alveolar walls, clinical pulmonary functions and CT images was investigated. CT scan was performed at the level of 50% vital capacity in both experimental models and clinical subjects by using spirometric gating CT. CT density histogram was obtained from CT image which was produced by using the developed software for this purpose. Densitometric parameters, such as mean CT value, %LAA, the peak in the histogram and 5% tile were selected from CT image. Papain solution of 5 mg/kg body weight was cumulatively administered to the left lower lobe in canine lung, resulting in the destruction of lung alveolar walls in parallel to the increasing dosage of papain. There was a significant correlation between not only the increasing dosage of papain, but also %FEV 1.0 and CT densitometric parameters, indicating that the histological changes of alveolar walls and the lung function in lung emphysema could be estimated by analysis of CT image. These experimental and clinical studies suggest that the analysis of CT image can reflect the pathophysiological changes in the lung and be useful for precise clinical diagnosis of lung emphysema. (author)

  19. Addison's disease due to adrenal tuberculosis: Contrast-enhanced CT features and clinical duration correlation

    International Nuclear Information System (INIS)

    Guo Yingkun; Yang Zhigang; Li Yuan; Ma Ensen; Deng Yuping; Min Pengqiu; Yin Longlin; Hu Jian; Zhang Xiaochun; Chen Tianwu

    2007-01-01

    Purpose: To describe CT morphology of untreated adrenal tuberculosis during the different stages of the natural history of the disease and to evaluate the diagnostic implications of CT features. Materials and methods: We retrospectively evaluated CT features in 42 patients with documented adrenal tuberculosis for the location, size, morphology, and enhancement patterns shown on CT images. The clinical duration were correlated with the CT features. Results: Of the 42 patients with untreated adrenal tuberculosis, bilaterally enlarged adrenal glands were revealed in 38 cases (91%), unilaterally enlarged in 3 cases (7%), and normal size in 1 case (2%). Of the 41 cases (98%) with enlargement, mass-like enlargement was seen in 20 cases (49%) and enlargement with preserved contours in 21 cases (51%). Peripheral rim enhancement presented in 22 cases (52%) on contrast-enhanced CT. Non-enhanced CT scan revealed calcification in 21 cases (50%). As the duration of Addison's disease increased, the presence of calcification and contour preservation increased concomitantly (p < 0.001), whereas peripheral rim enhancement and mass-like enlargement decreased concomitantly on CT images (p < 0.001). Conclusion: CT may be helpful in diagnosing adrenal tuberculosis when clinically suspected, and CT features are correlated to the clinical duration of Addison's disease

  20. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  1. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  2. Effect of clinical information in brain CT scan interpretation : a blinded double crossover study

    International Nuclear Information System (INIS)

    Zhianpour, M.; Janghorbani, M.

    2004-01-01

    Errors and variations in interpretation can happen in clinical imaging. Few studies have examined the biased effect of clinical information on reporting of brain CT scans. In a blinded double crossover design, we studied whether three radiologists were biased by clinical information when making CT scan diagnosis of the brain. Three consultant radiologists in three rounds with at least a one month interval assessed 100 consecutive cases of brain CT scan. In the first round, clinical information was not available and 100 films without clinical information were given to radiologists. In the second round, the same 100 films were given and true clinical information was available. In the third round, the same 100 films were given and false clinical information was allocated. In 180 cases (60%) the evaluation resulted in the same diagnosis on all three occasions (95% confidence interval (CI): 54.5, 65.5), whereas 120(40%; 95% CI:34.5, 45.5) sets were evaluated differently. 48 cases (16%; 95% CI:11.9,20.1) had discordant evaluation with true and 33 (11%; 95% CI:7.5, 14.5) with false clinical information. Discordance without and with true and false clinical information was 39 (13%; 95% CI:9.2, 16.8). Correct clinical information improves the brain CT report, while the report became less accurate false clinical information was allocated. These results indicate that radiologists are biased by clinical information when reporting brian CT scans

  3. Clinical utility of FDG PET/CT in acute complicated pyelonephritis - results from an observational study

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Hsing [Mackay Memorial Hospital at Taipei, Department of Nuclear Medicine, Taipei (China); Tseng, Jing-Ren; Yen, Tzu-Chen [Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan (China); Lee, Ming-Hsun [Chang Gung Memorial Hospital at Linkou, Division of Infectious Diseases, Department of Internal Medicine, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou, Biostatistics Unit, Clinical Trial Center, Taoyuan (China)

    2018-03-15

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of {sup 18}F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course. (orig.)

  4. How to choose PET-CT or CT in the diagnosis and staging of lung cancer. Practical experience in China

    International Nuclear Information System (INIS)

    Jiang, T.; Tao, X.; Liu, H.; Liu, S.; Zheng, X.

    2010-01-01

    How to use CT and PET-CT rationally to raise diagnosis, staging and prognostic assessment of lung cancer to a higher level at the best cost-effect ratio is a subject that Chinese clinicians and radiologists should face conscientiously. We review the rational application of CT and PET-CT in four aspects of lung cancer, including screening and detection, morphologic evaluation, haemodynamic or metabolic feature evaluation, and follow-up, staging and prognostic evaluation. As PET-CT is only available in class III-A hospitals today, CT is the most popular equipment in China. PET-CT is more valuable only in cases where CT presentation of lung cancer is atypical or difficult to determine, or in cases where the diagnosis of lung cancer has been initially confirmed, for which clinical staging and decision concerning on therapeutic regimens are needed. We also recommend the current strategies of CT and PET-CT managing of SPN in China. (orig.)

  5. Bacterial meningitis in newborn and infant: correlation between organism, CT findings and clinical outcome

    International Nuclear Information System (INIS)

    Choi, Hye Young; Park, Young Seo; Yoo, Shi Joon; Suh, Dae Chul; Chung, Young Kyo

    1993-01-01

    Acute bacterial meningitis often results in significant neurologic complications regardless of the antibiotics treatment Computed tomographic (CT) finding of tuberculous meningitis is fairly well known but not the findings of bacterial meningitis. This study was performed to determine the incidence of causative organisms and to correlate between the organisms and computed tomographic (CT) findings with clinical outcome of bacterial meningitis in newborns and infants. We analyzed the brain CT and clinical records of 15 infants who had been diagnosed as bacterial meningitis by CSF culture. We found that the most common organisms were Group B streptococcus in neonates without no neurologic complications in all but one and Hemophilus influenza in infants whose clinical outcomes were poor in all except one. CT findings related with poor prognosis in this study were cerebral edema, basal cisternal obliteration and enhancement, and cerebral infarction on initial CT and ventriculomegaly on follow-up CT. We concluded that CT diagnosed intracranial complications of bacterial meningitis well and could contributed to better treatment of bacterial meningitis

  6. Dynamic CT findings of eosinophilic hepatic abscess and its clinical course

    International Nuclear Information System (INIS)

    Cho, Dae Hyoun; Chang, Jae Chun; Seong, Ki Ho

    1996-01-01

    To evaluate dynamic CT features and its clinical courses of eosinophilic hepatic abscess. Two-phase dynamic CT findings and the clinical courses of 13 pathologically proven cases of eosinophilic abscess were reviewed. All patients showed peripheral eosinophilia, and diagnoses were confirmed by ultrasound-guided biopsy(n=9) or operation(n=4). In two of the four patients who underwent segmental hepatectomy, worms of the species fasciola hepatica were detected. Follow-up CT scans after treatment with antibiotics or praziquantel were available in seven and eitht patients, respectively. All hepatic lesions were found in a subcapsular location or in contact with Glisson's capsule around the bile duct Arterial-dominant phase CT(n=11) demonstrated clusters of ill-defined low density masses without rim enhancement. Late-phase CT(n=13) more clearly depicted clustering lesions with enhancing rims and diminyution of the low-density area. Follow-up CT scans after treatment with antibiotics(n=7) showed no change in the lesions in three patients and slight shrinkage of the main mass with additional new lesions in four. On CT scans of nine patients performad after praziquantel therapy, hepatic masses were seen in all patients to be very slightly smaller after improvement of peripheral hypereosinophilia. Two-phase dynamic CT features appear to be helpful for the diagnosis of eosinophilic hepatic abscess in patients with peripheral eosinophilia. Parasitic infestation by Fasciola hepatica for example, is the presumed cause of such abscesses, though further studies are required

  7. Dynamic CT findings of eosinophilic hepatic abscess and its clinical course

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Dae Hyoun; Chang, Jae Chun; Seong, Ki Ho [Yeungnam Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-01-01

    To evaluate dynamic CT features and its clinical courses of eosinophilic hepatic abscess. Two-phase dynamic CT findings and the clinical courses of 13 pathologically proven cases of eosinophilic abscess were reviewed. All patients showed peripheral eosinophilia, and diagnoses were confirmed by ultrasound-guided biopsy(n=9) or operation(n=4). In two of the four patients who underwent segmental hepatectomy, worms of the species fasciola hepatica were detected. Follow-up CT scans after treatment with antibiotics or praziquantel were available in seven and eitht patients, respectively. All hepatic lesions were found in a subcapsular location or in contact with Glisson's capsule around the bile duct Arterial-dominant phase CT(n=11) demonstrated clusters of ill-defined low density masses without rim enhancement. Late-phase CT(n=13) more clearly depicted clustering lesions with enhancing rims and diminyution of the low-density area. Follow-up CT scans after treatment with antibiotics(n=7) showed no change in the lesions in three patients and slight shrinkage of the main mass with additional new lesions in four. On CT scans of nine patients performad after praziquantel therapy, hepatic masses were seen in all patients to be very slightly smaller after improvement of peripheral hypereosinophilia. Two-phase dynamic CT features appear to be helpful for the diagnosis of eosinophilic hepatic abscess in patients with peripheral eosinophilia. Parasitic infestation by Fasciola hepatica for example, is the presumed cause of such abscesses, though further studies are required.

  8. CT coronary angiography: examination technique, clinical results, and outlook on future developments

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.

    2007-01-01

    Multislice computed tomography (MSCT) after intravenous contrast agent administration enables visualization of the coronary arteries with high spatial resolution (voxel sizes down to 0.5 x 0.35 x 0.35 mm3) and a short scan time. Magnetic resonance imaging (MRI) is also intensively studied with respect to the noninvasive detection of coronary artery stenosis and thus the detection of coronary artery disease (CAD) without radiation exposure but is not equal to MSCT at present. This article provides an overview of the historical development of CT coronary angiography from 4-slice CT to 16-slice CT and 64-slice CT. A crucial aspect of this development is the improvement in image quality resulting from shorter breath-hold periods and the reduced gantry rotation time. Other techniques that appear to considerably improve image quality and accuracy and make CT independent of patient heart rates are multisegment reconstruction and dual-source CT. Sublingual nitroglycerin as well as oral or intravenous betablocker administration should be considered in relation to the diagnostic question to be answered and the patient's heart rate. In the studies available CT coronary angiography with at least 12 simultaneous detector rows has a sensitivity of 96.9 % and a specificity of 75.3 % at the patient level. Especially the negative predictive value of CT (94.6 %) emphasizes the idea that this technique may reliably exclude CAD in patients with intermediate pretest likelihood. In the near future, 256-slice CT will allow examination of the entire heart during one heartbeat or even 4D CT scanning with simultaneous assessment of myocardial perfusion. Automatic or semiautomatic software tools will assume a central place in detecting and quantifying coronary artery stenoses and plaques as well as in the analysis of cardiac function in the clinical setting over the next years. Prior to its routine clinical use, the cost-effectiveness of CT coronary angiography must be determined and the

  9. Initial clinical experience with dual-layer detector spectral CT in patients with acute intracerebral haemorrhage: A single-centre pilot study.

    Directory of Open Access Journals (Sweden)

    Soo Buem Cho

    Full Text Available The purpose of this study was to investigate the clinical feasibility of spectral analyses using dual-layer detector spectral computed tomography (CT in acute intracerebral haemorrhage (ICH.We retrospectively reviewed patients with acute ICH who underwent CT angiography on a dual-layer detector spectral CT scanner. A spectral data analysis was performed to detect contrast enhancement in or adjacent to acute ICH by using spectral image reconstructions including monoenergetic (MonoE, virtual noncontrast (VNC, and iodine overlay fusion images. We also acquired a spectral plot to assess material differentiation within lesions.Among the 30 patients, the most common cause of acute ICH was chronic hypertension (18/30, 60% followed by trauma (5/30, 16.7%, brain tumour (3/30, 10%, Moyamoya disease (2/30, 6.7%, and haemorrhagic diathesis from anticoagulation therapy (2/30, 6.7%. Of 30 patients, 13 showed suboptimal iodine suppression in the subcalvarial spaces on VNC images compared with true noncontrast images. The CT angiographic spot sign within the acute ICH was detected in four patients (4/30, 13.3%. All three tumours were metastatic and included lung cancer (n = 2 and hepatocellular carcinoma (n = 1 which showed conspicuous delineation of an enhancing tumour portion in the spectral analysis. Spectral analyses allowed the discrimination of acute haemorrhage and iodine with enhanced lesion visualization on the MonoE images obtained at lower keVs (less than 70 keV and spectral plot.Even though the image quality of VNC is perceived to be inferior, it is feasible to evaluate acute ICH in clinical settings using dual-layer detector spectral CT. The MonoE images taken at lower keVs were useful for depicting contrast enhancing lesion, and spectral plot might be helpful for material differentiation in patients with acute ICH.

  10. Initial clinical experience with dual-layer detector spectral CT in patients with acute intracerebral haemorrhage: A single-centre pilot study.

    Science.gov (United States)

    Cho, Soo Buem; Baek, Hye Jin; Ryu, Kyeong Hwa; Moon, Jin Il; Choi, Bo Hwa; Park, Sung Eun; Bae, Kyungsoo; Jeon, Kyung Nyeo; Kim, Dong Wook

    2017-01-01

    The purpose of this study was to investigate the clinical feasibility of spectral analyses using dual-layer detector spectral computed tomography (CT) in acute intracerebral haemorrhage (ICH). We retrospectively reviewed patients with acute ICH who underwent CT angiography on a dual-layer detector spectral CT scanner. A spectral data analysis was performed to detect contrast enhancement in or adjacent to acute ICH by using spectral image reconstructions including monoenergetic (MonoE), virtual noncontrast (VNC), and iodine overlay fusion images. We also acquired a spectral plot to assess material differentiation within lesions. Among the 30 patients, the most common cause of acute ICH was chronic hypertension (18/30, 60%) followed by trauma (5/30, 16.7%), brain tumour (3/30, 10%), Moyamoya disease (2/30, 6.7%), and haemorrhagic diathesis from anticoagulation therapy (2/30, 6.7%). Of 30 patients, 13 showed suboptimal iodine suppression in the subcalvarial spaces on VNC images compared with true noncontrast images. The CT angiographic spot sign within the acute ICH was detected in four patients (4/30, 13.3%). All three tumours were metastatic and included lung cancer (n = 2) and hepatocellular carcinoma (n = 1) which showed conspicuous delineation of an enhancing tumour portion in the spectral analysis. Spectral analyses allowed the discrimination of acute haemorrhage and iodine with enhanced lesion visualization on the MonoE images obtained at lower keVs (less than 70 keV) and spectral plot. Even though the image quality of VNC is perceived to be inferior, it is feasible to evaluate acute ICH in clinical settings using dual-layer detector spectral CT. The MonoE images taken at lower keVs were useful for depicting contrast enhancing lesion, and spectral plot might be helpful for material differentiation in patients with acute ICH.

  11. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    International Nuclear Information System (INIS)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso; Kuruoshi, Marcia Etsuko

    2009-01-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  12. Finding of CT and clinical in paraquat poisoning pulmonary injury

    International Nuclear Information System (INIS)

    He Zaifang; Li Hongbing; Cheng Shoulin; Li Qixiang; Huang Zhen; Zeng Jianguo

    2012-01-01

    Objective: To investigate the CT features of pulmonary injury in paraquat poisoning. Methods: The chest CT image of lung injury in 6 cases of paraquat poisoning were analyzed retrospectively. According to different period of poisoning, the 6 cases were divided into 3 types:the early stage of poisoning (within 2 d), the middle stage of poisoning (3-14 d), the late stage of poisoning (>14 d). A comparison between CT signs and the pathological features of patients was made. Results: Among this 6 cases, 3 cases died, 2 cases pulmonary fibrosis was noted, 1 cases recovered. According to different period of poisoning, the 6 cases were divided into 3 stages: in the early stage of poisoning (within 2 d), 3 cases of all patients showed nothing remarkable, 2 cases showed ground-glass opacity, 1 case showed fuzzy lung-marking.In the middle stage of poisoning (3-14 d), all 6 cases showed ground-glass opacity, mosaic attenuation; 6 cases showed pulmonary consolidation; 4 cases showed subpleural lines; 4 cases showed bronchiectasis; 2 cases showed mid-lower pleural effusion. In the late stage of poisoning (>14 d), 4 cases showed pulmonary consolidation and pulmonary fibrosis, 3 cases showed ground-glass opacity and mosaic attenuation, 1 case showed mid-lower pleural effusion; 1 case showed mediastinal emphysema. Conclusion: The clinical pathology process of paraquat poisoning was in line with CT finding which was related with clinical stage and was helpful for clinical assessment of paraquat poisoning promptly and to guide the clinical treatment. (authors)

  13. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  14. Respiratory Motion Management in PET/CT: Applications and Clinical Usefulness.

    Science.gov (United States)

    Guerra, Luca; Ponti, Elena De; Morzenti, Sabrina; Spadavecchia, Chiara; Crivellaro, Cinzia

    2017-01-01

    Breathing movement can introduce heavy bias in both image quality and quantitation in PET/CT. The aim of this paper is a review of the literature to evaluate the benefit of respiratory gating in terms of image quality, quantification and lesion detectability. A review of the literature published in the last 10 years and dealing with gated PET/CT technique has been performed, focusing on improvement in quantification, lesion detectability and diagnostic accuracy in neoplastic lesion. In addition, the improvement in the definition of radiotherapy planning has been evaluated. There is a consistent increase of the Standardized Uptake Value (SUV) in gated PET images when compared to ungated ones, particularly for lesions located in liver and in lung. Respiratory gating can also increase sensitivity, specificity and accuracy of PET/CT. Gated PET/CT can be used for radiation therapy planning, reducing the uncertainty in target definition, optimizing the volume to be treated and reducing the possibility of "missing" during the dose delivery. Moreover, new technologies, able to define the movement of lesions and organs directly from the PET sinogram, can solve some problems that currently are limiting the clinical use of gated PET/CT (i.e.: extended acquisition time, radiation exposure). The published literature demonstrated that respiratory gating PET/CT is a valid technique to improve quantification, lesion detectability of lung and liver tumors and can better define the radiotherapy planning of moving lesions and organs. If new technical improvements for motion compensation will be clinically validated, gated technique could be applied routinely in any PET/CT scan. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. Perigastric appendagitis: CT and clinical features in eight patients

    International Nuclear Information System (INIS)

    Justaniah, A.I.; Scholz, F.J.; Katz, D.S.; Scheirey, C.D.

    2014-01-01

    Aim: To describe perigastric appendagitis (PA) on CT as a new and distinct clinical entity to enable recognition and prevent additional unnecessary investigation or intervention. Materials and methods: Institutional review board approval was obtained and informed consent was waived. Retrospective review of the clinical data and CT findings in eight patients with PA encountered over 10 years at one institution was performed. The English literature was reviewed and summarized. Two experienced abdominal radiologists reviewed the CT images by consensus. Results: Seven of eight patients had moderate to severe epigastric pain for 1–7 days. All eight patients (four men, four women; mean age 44 years, range 33–81 years) had no fever or leukocytosis. All underwent abdominal CT which showed ovoid fat inflammation along the course of the perigastric ligaments (gastrohepatic, gastrosplenic, and falciform). Two had gastric wall thickening. Although the inflammation was correctly described, the specific diagnosis was not made on initial interpretation in five patients. Subsequently, they underwent further diagnostic testing [an upper gastrointestinal examination and hepatobiliary iminodiacetic acid (HIDA) cholescintigraphy, an upper endoscopy and MRI examination, HIDA cholescintigraphy, another CT, and an MRI examination, respectively]. The HIDA cholescintigraphy, upper GI examination, and upper endoscopy examinations were normal. No repeated examination was performed on the other three patients. Pain resolved spontaneously in all within two days. Conclusion: Perigastric appendagitis can present with an acute abdomen, which is safely managed conservatively if diagnosed correctly. Radiologists should be aware of the entity to avoid unnecessary intervention, and recognize the CT findings of ovoid fat inflammation in the distribution of the perigastric ligaments. - Highlights: • Normal perigastric ligaments can have fatty appendages. • Torsion of these appendages causes

  16. CT findings of transfusional hemosiderosis in patients with chronic renal failure : clinical correlation

    International Nuclear Information System (INIS)

    Park, Tae Joon; Lee, Hae Kyung; Hong, Hyun Sook; Kim, Gun Woo; Kim, Hyung Hwan; Choi, Gyo Chang; Kwon, Kui Hyang; Choi, Deuk Lin

    1997-01-01

    The purpose of this study is to evaluate whether there is any correlation between the CT features of hemosiderosis and clinical findings in patients with chronic renal failure who have received multiple blood transfusion. Among chronic renal failure patients who had undergone long-tern dialysis and received multiple blood transfusions, CT findings in 16 cases in which increased liver attenuation was seen on images obtained for other purpose, were analyzed by three radiologic specialists. The attenuation values of liver, spleen and pancreas compared with that of back muscle were correlated with the amount and duration of transfusion, and blood ferritin level. There is no correlation between the CT features of hemosiderosis and clinical findings. In patients with chronic renal failure and no clinical symptoms, the status of iron overload was relatively easily detected on CT. Close observation of CT findings is thus thought to prevent significant permanent functional deformity of organs in patients with chronic renal failure who have received multiple blood transfusions. (author). 14 refs., 1 tab., 1 fig

  17. Clinical protocol for conducting a bone scintigraphy subsequent SPECT/CT examination

    International Nuclear Information System (INIS)

    Jovanovska, A.; Dimcheva, M.; Doldurova, M.

    2013-01-01

    Full text: Introduction: Like any nuclear medicine study, bone scintigraphy is a diagnostic procedure associated with intravenous injection of a radioactive isotope with low activity - radiopharmaceutical. But recently in clinical practice hybrid imaging methods such as SPECT/ CT (Single Photon Emission Tomography - Computed Tomography) has necessitated, as they provide comprehensive information about the function and structure of the studied organ. Materials and methods: In the Department of Nuclear Medicine in The Specialized Hospital for Active Treatment of Oncology Diseases in Sofia it is installed a two-detector SPECT/CT gamma camera Siemens Symbia T2, on which the whole range of nuclear medicine studies in oncology practice is held: bone scintigraphy, 99mTc - MIBI scintigraphy, Lymphoscintigraphy, somatostatin receptor scintigraphy, tireostsintigraphy with 131I/99mTc, dynamic nephroscintgraphy etc. The working algorithm upon choosing the clinical protocols, and setting the parameters for scanning are complied with the requirements and recommendations established by the nuclear medicine standard. The presented are results from studies of patients when after whole body bone scintigraphy, an additional SPECT/CT study was conducted for more accurate diagnostic and interpretation of the results. Results: Practical introduction of hybrid imaging methods require from technicians besides knowledge in working with radioactive sources and practical skills such as: the selection of the matrix size, number of projections, choice of trajectory - circular or elliptical, set the appropriate degree of rotation of the detector (180 or 360). Particularly important in the processing of MR images is the appropriate choice of algorithm of reconstruction: filtered backprojection or iterative reconstruction methods. In MR images processing there is no rule for the optimal filter, which is why the quality of the reconstructed image depends primarily on the experience of the operator

  18. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  19. Clinical and CT patterns in phakomatosis after Bourneville-Pringle

    International Nuclear Information System (INIS)

    Grobovschek, M.; Bone, G.; Landesnervenklinik, Salzburg

    1987-01-01

    The various clinical patterns of Bourneville's disease and/or Pringle's disease (pharkomatosis, or tuberous sclerosis combined with adenoma sebaceum) are described compared with CT morphology of the neurocranium. (orig.) [de

  20. WE-FG-207A-02: Why We Need Breast CT? - Clinical Perspective

    International Nuclear Information System (INIS)

    O’Connell, A.

    2016-01-01

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  1. WE-FG-207A-02: Why We Need Breast CT? - Clinical Perspective

    Energy Technology Data Exchange (ETDEWEB)

    O’Connell, A. [University of Rochester Medical Center (United States)

    2016-06-15

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  2. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  3. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  4. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  5. Clinical value of FDG PET/CT in the diagnosis of suspected recurrent ovarian cancer: is there an impact of FDG PET/CT on patient management?

    International Nuclear Information System (INIS)

    Bilici, Ahmet; Ustaalioglu, Bala Basak Oven; Seker, Mesut; Salepci, Taflan; Gumus, Mahmut; Canpolat, Nesrin; Tekinsoy, Bulent

    2010-01-01

    The aim of this study was to evaluate the clinical value of FDG PET/CT in patients with suspected ovarian cancer recurrence as compared with diagnostic CT, and to assess the impact of the results of FDG PET/CT on treatment planning. Included in this retrospective study were 60 patients with suspected recurrent ovarian cancer who had previously undergone primary debulking surgery and had been treated with adjuvant chemotherapy. Diagnostic CT and FDG PET/CT imaging were performed for all patients as clinically indicated. The changes in the clinical management of patients according to the results of FDG PET/CT were also analysed. FDG PET/CT was performed in 21 patients with a previously negative or indeterminate diagnostic CT scan, but an elevated CA-125 level, and provided a sensitivity of 95% in the detection of recurrent disease. FDG PET/CT revealed recurrent disease in 19 patients. In 17 of 60 patients, the indication for FDG PET/CT was an elevated CA-125 level and an abnormal diagnostic CT scan to localize accurately the extent of disease. FDG PET/CT scans correctly identified recurrent disease in 16 of the 17 patients, a sensitivity of 94.1%. Moreover, FDG PET/CT was performed in 18 patients with clinical symptoms of ovarian cancer recurrence, an abnormal diagnostic CT scan, but a normal CA-125 level. In this setting, FDG PET/CT correctly confirmed recurrent disease in seven patients providing a sensitivity of 100% in determining recurrence. In four patients, FDG PET/CT was carried out for the assessment of treatment response. Three of four scans were classified as true-negative indicating a complete response. In the other patient, FDG PET/CT identified progression of disease. In total, 45 (75%) of the 60 patients had recurrent disease, in 14 (31.1%) documented by histopathology and in 31 (68.9%) on clinical follow-up, while 15 (25%) had no evidence of recurrent disease. The overall sensitivity, specificity, accuracy, and positive and negative predictive value

  6. CT of jejunal diverticulitis: imaging findings, differential diagnosis, and clinical management

    International Nuclear Information System (INIS)

    Macari, M.; Faust, M.; Liang, H.; Pachter, H.L.

    2007-01-01

    Aim: To describe the imaging findings of jejunal diverticulitis as depicted at contrast-enhanced computed tomography (CT) and review the differential diagnosis and clinical management. Materials and Methods: CT and pathology databases were searched for the diagnosis of jejunal diverticulitis. Three cases were identified and the imaging and clinical findings correlated. Results: Jejunal diverticulitis presents as a focal inflammatory mass involving the proximal small bowel. A trial of medical management with antibiotics may be attempted. Surgical resection may be required if medical management is unsuccessful. Conclusion: The imaging findings at MDCT may allow a specific diagnosis of jejunal diverticulitis to be considered and may affect the clinical management of the patient

  7. Central image archiving and managements system for multicenter clinical studies: Lessons from low-dose CT for appendicitis trial

    Energy Technology Data Exchange (ETDEWEB)

    Ko, You Sun; Lee, Kyong Joon; Lee, Kyoung Ho [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); and others

    2017-03-15

    This special report aimed to document our experiences in implementing the Central Imaging Archiving and Management System (CIAMS) for a multicenter clinical trial, Low-dose CT for Appendicitis Trial (LOCAT), supported by the Korean Society of Radiology and Radiology Imaging Network of Korea for Clinical Research. LOCAT was a randomized controlled trial to determine whether low-dose CT is non-inferior to standard-dose CT with respect to the negative appendectomy rate in patients aged from 15 to 44 years. Site investigators downloaded the CT images from the site picture archiving and communication system servers, and uploaded the anonymized images to the primary server. CIAMS administrators inspected the images routed to the secondary server by a cross-check against image submission worksheets provided by the site investigators. The secondary server was automatically synchronized to the tertiary backup server. Up to June 2016, 2715 patients from 20 sites participated in LOCAT for 30 months. A total of 2539 patients' images (93.5%, 2539/2715) were uploaded to the primary server, 2193 patients' worksheets (80.8%, 2193/2715) were submitted, and 2163 patients' data (79.7%, 2163/2715) were finally monitored. No data error occurred.

  8. Clinical and CT patterns in phakomatosis after Bourneville-Pringle

    Energy Technology Data Exchange (ETDEWEB)

    Grobovschek, M.; Bone, G.

    1987-06-01

    The various clinical patterns of Bourneville's disease and/or Pringle's disease (pharkomatosis, or tuberous sclerosis combined with adenoma sebaceum) are described compared with CT morphology of the neurocranium.

  9. Acute appendicitis in children: comparison of clinical diagnosis with ultrasound and CT imaging

    International Nuclear Information System (INIS)

    Karakas, S.P.; Guelfguat, M.; Springer, S.; Singh, S.P.; Leonidas, J.C.

    2000-01-01

    Background. There is strong evidence that imaging with ultrasound and CT can be of substantial diagnostic value in the diagnosis of acute appendicitis in children, but there is limited information of the impact of imaging on the management of these patients and its possible effect on surgical findings. Objective. We studied the impact of imaging in the management of acute appendicitis, in particular its effect on the rate of negative appendectomies and perforations. Patients and methods. We reviewed retrospectively the clinical records and imaging findings of 633 consecutive children and adolescents seen on an emergency basis with clinical suspicion of acute appendicitis. Two hundred seventy patients were operated upon on clinical evidence alone, while 360 were referred for US or CT, and occasionally both, because of doubtful clinical findings. Results. Acute appendicitis was found in 237 of those on clinical grounds alone, 68 of whom had perforation and related complications. Thus the rate of negative exploration and the rate of perforation were13 % and 29 %, respectively. One hundred eighty-two patients had preoperative US (sensitivity 74 %, specificity 94 %), 119 had CT (sensitivity 84 %, specificity 99 %), and 59 had both US and CT (sensitivity 75 %, specificity 100 %, but often with interpretation at variance with each other). The rate of negative appendectomy and perforation was 8 % and 23 %, respectively, for US, 5 % and 54 % for CT, and 9 % and 71 % when both examinations were performed. There is no statistical significance between the rates of diagnostic performance of US, CT, or their combination, nor between the negative appendectomy rates of each group, but the rate of perforation was significantly higher when CT was performed, alone or after US. Conclusion. The retrospective nature of the study prevents precise definition of the clinical characteristics and selection criteria for diagnostic examinations that may contribute to the management of children

  10. CT abnormality in multiple sclerosis analysis based on 28 probable cases and correlation with clinical manifestations

    International Nuclear Information System (INIS)

    Kakigi, Ryusuke; Shibasaki, Hiroshi; Tabira, Takeshi; Kuroiwa, Yoshigoro; Numaguchi, Yuji.

    1981-01-01

    In order to investigate the occurrence and nature of CT abnormality and its correlation with clinical manifestations in multiple sclerosis, 34 CT records obtained from 28 consecutive patients with probable multiple sclerosis were reviewed. Forty-six percent of all cases showed abnormal CT. Dilatation of cortical sulci was found in 39%; dilatation of the lateral ventricle in 36%; dilatation of prepontine or cerebello-pontine cistern and the fourth ventricle, suggesting brainstem atrophy, in 18%; dilatation of cerebellar sulci, superior cerebellar cistern and cisterna magna, suggesting cerebellar atrophy, in 11%. Low density area was found in the cerebral hemisphere in 11% of cases. Contrast enhancement, performed on 25 CT records, did not show any change. There was no correlation between CT abnormality and duration of the illness. Although abnormal CT tended to occur more frequently during exacerbations and chronic stable state than during remissions, the difference was not statistically significant. CT abnormalities suggesting brainstem atrophy, cerebellar atrophy or plaques were found exclusively during exacerbations and chronic stable state. The occurrence of CT abnormalities was not significantly different among various clinical forms which were classified based on clinically estimated sites of lesion, except that abnormal CT tended to occur less frequently in cases classified as the optic-spinal form. It is noteworthy that cerebral cortical atrophy and/or dilatation of the lateral ventricle were found in 31% of cases who did not show any clinical sign of cerebral involvement. There was a statistically significant correlation between CT abnormalities and levels of clinical disability. Eighty percent of the bedridden or severely disabled patients showed abnormal CT, in contrast with only 29% of those with moderate, slight or no disability. (author)

  11. CT abnormality in multiple sclerosis analysis based on 28 probable cases and correlation with clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kakigi, R.; Shibasaki, H.; Tabira, T.; Kuroiwa, Y. (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine); Numaguchi, Y.

    1981-10-01

    In order to investigate the occurrence and nature of CT abnormality and its correlation with clinical manifestations in multiple sclerosis, 34 CT records obtained from 28 consecutive patients with probable multiple sclerosis were reviewed. Forty-six percent of all cases showed abnormal CT. Dilatation of cortical sulci was found in 39%; dilatation of the lateral ventricle in 36%; dilatation of prepontine or cerebello-pontine cistern and the fourth ventricle, suggesting brainstem atrophy, in 18%; dilatation of cerebellar sulci, superior cerebellar cistern and cisterna magna, suggesting cerebellar atrophy, in 11%. Low density area was found in the cerebral hemisphere in 11% of cases. Contrast enhancement, performed on 25 CT records, did not show any change. There was no correlation between CT abnormality and duration of the illness. Although abnormal CT tended to occur more frequently during exacerbations and chronic stable state than during remissions, the difference was not statistically significant. CT abnormalities suggesting brainstem atrophy, cerebellar atrophy or plaques were found exclusively during exacerbations and chronic stable state. The occurrence of CT abnormalities was not significantly different among various clinical forms which were classified based on clinically estimated sites of lesion, except that abnormal CT tended to occur less frequently in cases classified as the optic-spinal form. It is noteworthy that cerebral cortical atrophy and/or dilatation of the lateral ventricle were found in 31% of cases who did not show any clinical sign of cerebral involvement. There was a statistically significant correlation between CT abnormalities and levels of clinical disability. Eighty percent of the bedridden or severely disabled patients showed abnormal CT, in contrast with only 29% of those with moderate, slight or no disability.

  12. Clinical feasibility of {sup 90}Y digital PET/CT for imaging microsphere biodistribution following radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Chadwick L.; Binzel, Katherine; Zhang, Jun; Knopp, Michael V. [The Ohio State University Wexner Medical Center, Wright Center of Innovation in Biomedical Imaging, Department of Radiology, Columbus, OH (United States); Wuthrick, Evan J. [The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Columbus, OH (United States)

    2017-07-15

    The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following {sup 90}Y microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC {sup 90}Y bremsstrahlung imaging immediately following routine radioembolization with 3.5 ± 1.7 GBq of {sup 90}Y-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 ± 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and {sup 90}Y biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of {sup 90}Y activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and {sup 90}Y-to-background image contrast while depicting {sup 90}Y biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined {sup 90}Y activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of {sup 90}Y microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of {sup 90}Y microsphere biodistribution. (orig.)

  13. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting.

    Science.gov (United States)

    Kumarasiri, Akila; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J; Kim, Jinkoo

    2014-12-01

    To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H&N) adaptive radiotherapy. Ten H&N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3-4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm(3). Organs with volumes <3 cm(3) and/or those with poorly defined boundaries showed Dice coefficients of ∼ 0.5-0.6. For the propagation of small organs (<3 cm(3)), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was "clinically acceptable with minor modification or major modification in a small number of contours." Use of DIR-based contour propagation in the routine

  14. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

    International Nuclear Information System (INIS)

    Kumarasiri, Akila; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J.; Kim, Jinkoo

    2014-01-01

    Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm 3 . Organs with volumes <3 cm 3 and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm 3 ), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours.” Conclusions

  15. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

    Energy Technology Data Exchange (ETDEWEB)

    Kumarasiri, Akila, E-mail: akumara1@hfhs.org; Siddiqui, Farzan; Liu, Chang; Yechieli, Raphael; Shah, Mira; Pradhan, Deepak; Zhong, Hualiang; Chetty, Indrin J.; Kim, Jinkoo [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202 (United States)

    2014-12-15

    Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreement of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm{sup 3}. Organs with volumes <3 cm{sup 3} and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm{sup 3}), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of contours

  16. Early clinical esophageal adenocarcinoma (cT1): Utility of CT in regional nodal metastasis detection and can the clinical accuracy be improved?

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt Cuellar, Sonia L., E-mail: slbetancourt@mdanderson.org; Sabloff, Bradley, E-mail: bsabloff@mdanderson.org; Carter, Brett W., E-mail: bcarter2@mdanderson.org; Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org; Correa, Arlene M., E-mail: amcorrea@mdanderson.org; Maru, Dipen M., E-mail: dmaru@mdanderson.org; Ajani, Jaffer A., E-mail: jajani@mdanderson.org; Erasmus, Jeremy J., E-mail: jerasmus@mdanderson.org; Hofstetter, Wayne L., E-mail: whofstetter@mdanderson.org

    2017-03-15

    Introduction: Treatment of early esophageal cancer depends on the extent of the primary tumor and presence of regional lymph node metastasis.(RNM). Short axis diameter >10 mm is typically used to detect RNM. However, clinical determination of RNM is inaccurate and can result in inappropriate treatment. Purpose of this study is to evaluate the accuracy of a single linear measurement (short axis > 10 mm) of regional nodes on CT in predicting nodal metastasis, in patients with early esophageal cancer and whether using a mean diameter value (short axis + long axis/2) as well as nodal shape improves cN designation. Methods: CTs of 49 patients with cT1 adenocarcinoma treated with surgical resection alone were reviewed retrospectively. Regional nodes were considered positive for malignancy when round or ovoid and mean size >5 mm adjacent to the primary tumor and >7 mm when not adjacent. Results were compared with pN status after esophagectomy. Results: 18/49 patients had pN+ at resection. Using a single short axis diameter >10 mm on CT, nodal metastasis (cN) was positive in 7/49. Only 1 of these patients was pN+ at resection (sensitivity 5%, specificity 80%, accuracy 53%). Using mean size and morphologic criteria, cN was positive in 28/49. 11 of these patients were pN+ at resection (sensitivity 61%, specificity 45%, accuracy 51%). EUS with limited FNA of regional nodes resulted in 16/49 patients with pN+ being inappropriately designated as cN0. Conclusions: Evaluation of size, shape and location of regional lymph nodes on CT improves the sensitivity of cN determination compared with a short axis measurement alone in patients with cT1 esophageal cancer, although clinical utility is limited.

  17. Clinical investigation of CT-guided ozone-blowing and fumigation ...

    African Journals Online (AJOL)

    Clinical investigation of CT-guided ozone-blowing and fumigation therapy for the chronic ... African Journal of Biotechnology ... In control group, seven patients were completely cured in 45 days after being treated by traditional surgery.

  18. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    Science.gov (United States)

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (Ppannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    International Nuclear Information System (INIS)

    Breen, Micheal; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  20. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  1. Clinical value of SPECT/CT imaging in the diagnosis of bone metastasis

    International Nuclear Information System (INIS)

    Wang Xinhua; Zhao Yanping; Lu Haijian; Dong Zhanfei

    2010-01-01

    Objective: To evaluate the clinical value of 99 Tc m -methylene diphosphonic acid (MDP) SPECT/CT imaging for the diagnosis of bone metastasis. Methods: Patients suspected for bone metastasis and with bone pain of unknown origin were included in this study (n=237). All cases underwent SPECT and CT imaging at 180 min after 99 Tc m -MDP injection. Diagnosis was confirmed by pathology (n=21), more than 2 kinds of radiologieal imaging (MRI, CT, X-ray) (n=106), and clinical follow up in 2 years (n=110). χ 2 -test was used to compare the results of planar and SPECT/CT imaging using SAS 6.12 software. Results: In 237 patients, planar imaging of 142 cases matched the final diagnosis in which 72 had benign lesions and 70 had bone metastases. The definite coincidence rate was 95.30% (142/149). SPECT/CT imaging of 224 cases matched the final diagnosis in which 104 had benign lesions and 120 cases diagnosed as bone metastases. The coincidence and definite coincidence rates were 94.51% (224/237), and 99.48% (192/193). Difference in the definite coincidence rate between planar and SPECT/CT imaging was statistically significant (χ 2 = 5.37, P=0.024). Conclusion: SPECT/CT imaging is valuable for accurate localization of osseous pathology and for improvement of diagnosing bone metastasis. (authors)

  2. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    Science.gov (United States)

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  3. CT diagnosis and clinical of leukoaraosis (with 145 cases report)

    International Nuclear Information System (INIS)

    Yang Minzheng

    2005-01-01

    Objective: To investigate pathogenesis of leukoaraosis, the correlation between CT presentation and clinical symptom and to provide useful evidence for clinical diagnosis and treatment. Methods: CT presentation and clinical symptoms in the Leukoaraosis of 145 cases were retrospectively analyzed. Results: Leukoaraosis manifested symmetrical hypo-dense lesion adjacent to frontal horn and/or occipital horn of bilateral ventricles; symmetrical hypo-dense peri-ventricle patches; or diffuse hypo-dense white matter. Lacunar infarction or hemorrhage of basal ganglion and/or thalamus may also be revealed. Conclusion: Leukoaraosis often involves the white matter adjacent to the frontal horn and occipital horn of bilateral ventricles. And entire peri-ventricle white matter may be affected in severe cases. The pathology of the disease is related to demyelination of brain white matter, resulting in the characteristic vascularity in white matter, which may alter under hypertension. (authors)

  4. Clinical data and CT findings of pulmonary infection caused by different pathogens after kidney transplantation

    International Nuclear Information System (INIS)

    Jiang Tao; Xue Feng; Zheng Xuan; Yu Hong; Tao Xiaofeng; Xiao Xiangsheng; Liu Shiyuan

    2012-01-01

    Purpose: The overall objective was to review clinical data and CT findings of pulmonary infection caused by different pathogens after kidney transplantation in an attempt to help early clinical qualitative diagnosis. Materials and methods: 446 cases of clinically confirmed pulmonary infection after kidney transplantation in recent 10 years were evaluated with respect to the time of occurrence and 89 cases with complete CT data and pathogenic diagnosis were further analyzed for pathogen types and CT manifestations. Statistical analysis was performed using Fisher's exact test. Results: Pulmonary infection reached the peak in 3 months after transplantation. Bacterial infection and mixed infection were predominant between 1 and 6 months. And most tuberculosis occurred after one year. Bacterial (38.2%) and mixed infections (38.2%) were the common types. The next was fungal infection, tuberculosis and viral infection (10.1%, 7.9% and 5.6%, respectively). CT manifestations of pulmonary infections after kidney transplantation were diverse and complex, lacking characteristic signs. Conclusion: More than 3/4 of pulmonary infections after kidney transplantation can be attributed to bacteria and mixed pathogens. The combination of time course, clinical data and CT manifestations plays an important role in the early clinical qualitative diagnosis.

  5. CT-semiotics and clinical aspects of extrinsic allergic alveolitis

    International Nuclear Information System (INIS)

    Skrynnikova, I.P.; Momot, N.V.; Vakulenko, I.P.; Tanasichuk-Gazhieva, N.V

    2003-01-01

    Extrinsic allergic alveolitis can be a difficult diagnostic problem. The comparison of the results of CT research with the clinical immunological and morphological data allowed to define the forms and diagnose the characteristic symptoms of the disease

  6. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures.

    Science.gov (United States)

    Chapman, Brandon C; Overbey, Douglas M; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T; French, Andrew; Johnson, Jeffrey L; Burlew, Clay C; Barnett, Carlton; Moore, Ernest E; Pieracci, Fredric M

    2016-12-01

    Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Retrospective cohort study of blunt trauma patients with rib fractures at a level I trauma center that had both a CXR and a CT chest. The CT finding of ≥ 3 additional fractures in patients with ≤ 3 rib fractures on CXR was considered clinically meaningful. Student's t-test and chi-square analysis were used for comparison. We identified 499 patients with rib fractures: 93 (18.6%) had CXR only, 7 (1.4%) had chest CT only, and 399 (79.9%) had both CXR and chest CT. Among these 399 patients, a total of 1,969 rib fractures were identified: 1,467 (74.5%) were missed by CXR. The median number of additional fractures identified by CT was 3 (range, 4 - 15). Of 212 (53.1%) patients with a clinically meaningful increase in the number of fractures, 68 patients underwent one or more clinical interventions: 36 SICU admissions, 20 pain catheter placements, 23 epidural placements, and 3 SSRF. Additionally, 70 patients had a chest tube placed for retained hemothorax or occult pneumothorax. Overall, 138 patients (34.5%) had a change in clinical management based upon CT chest. The chest X-ray missed ~75% of rib fractures seen on chest CT. Although patients with a clinical meaningful increase in the number of rib fractures were more likely to be admitted to the intensive care unit, there was no associated improvement in pulmonary outcomes.

  7. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  8. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  9. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Scott and White Healthcare System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  10. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2016-01-01

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  11. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  12. Added value of CT perfusion compared to CT angiography in predicting clinical outcomes of stroke patients treated with mechanical thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Tsogkas, Ioannis; Knauth, Michael; Schregel, Katharina; Behme, Daniel; Psychogios, Marios Nikos [University Medicine Goettingen, Department of Neuroradiology, Goettingen (Germany); Wasser, Katrin; Maier, Ilko; Liman, Jan [University Medicine Goettingen, Department of Neurology, Goettingen (Germany)

    2016-11-15

    CTP images analyzed with the Alberta stroke program early CT scale (ASPECTS) have been shown to be optimal predictors of clinical outcome. In this study we compared two biomarkers, the cerebral blood volume (CBV)-ASPECTS and the CTA-ASPECTS as predictors of clinical outcome after thrombectomy. Stroke patients with thrombosis of the M1 segment of the middle cerebral artery were included in our study. All patients underwent initial multimodal CT with CTP and CTA on a modern CT scanner. Treatment consisted of full dose intravenous tissue plasminogen activator, when applicable, and mechanical thrombectomy. Three neuroradiologists separately scored CTP and CTA images with the ASPECTS score. Sixty-five patients were included. Median baseline CBV-ASPECTS and CTA-ASPECTS for patients with favourable clinical outcome at follow-up were 8 [interquartile range (IQR) 8-9 and 7-9 respectively]. Patients with poor clinical outcome showed a median baseline CBV-ASPECTS of 6 (IQR 5-8, P < 0.0001) and a median baseline CTA-ASPECTS of 7 (IQR 7-8, P = 0.18). Using CBV-ASPECTS and CTA-ASPECTS raters predicted futile reperfusions in 96 % and 56 % of the cases, respectively. CBV-ASPECTS is a significant predictor of clinical outcome in patients with acute ischemic stroke treated with mechanical thrombectomy. (orig.)

  13. Focal breast lesions in clinical CT examinations of the chest. A retrospective analysis

    International Nuclear Information System (INIS)

    Krug, Kathrin Barbara; Houbois, Christian; Grinstein, Olga; Borggrefe, Jan; Puesken, Michael; Maintz, David; Hanstein, Bettina; Malter, Wolfram; Hellmich, Martin

    2017-01-01

    Based on radiological reports, the percentage of breast cancers visualized as incidental findings in routine CT examinations is estimated at ≤2%. In view of the rising number of CT examinations and the high prevalence of breast cancer, it was the goal of the present study to verify the frequency and image morphology of false-negative senological CT findings. All first contrast-enhanced CT examinations of the chest in adult female patients carried out in 2012 were retrospectively included. A senior radiologist systematically assessed the presence of breast lesions on all CT images using the BI-RADS system. All BI-RADS ≥3 notations were evaluated by a second senior radiologist. A consensus was obtained in case of differing BI-RADS assessments. Reference diagnoses were elaborated based on all available clinical, radiological and pathological data. The findings of the CT reports were classified according to the BI-RADS system and were compared with the retrospective consensus findings as well as with the reference diagnoses. The range of indications comprised a broad spectrum including staging and follow-up examinations of solid tumors/lymphoma (N = 701, 59.9 %) and vascular (190, 16.2 %), inflammatory (48, 4.1 %) and pulmonologic (22, 1.9 %) issues. BI-RADS 1/2 classifications were present in 92.5 % and BI-RADS 6 classifications were assessed in 1.7 % of the 1170 included examinations. 68 patients (5.8 %) had at least one lesion retrospectively classified as BI-RADS 3 - 5. The histological potential was known in 57 of these lesions as benign (46, 3.9 %) or malignant (11, 0.9 %). 13 BI-RADS 4/5 consensus assessments (1.1 %) were false-positive. 2 of the 10 lesions classified as being malignant based on the further clinical and radiological course were not mentioned in the written CT reports (0.2 %). Both false-negative CT reports were therapeutically and prognostically irrelevant. The relative frequency of BI-RADS 3 - 5 findings was 5.8 %. It reflects the situation

  14. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Walkup, Laura L. [Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States); Woods, Jason C. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Center for Pulmonary Imaging Research, Pulmonary Medicine and Radiology, Cincinnati, OH (United States)

    2016-12-15

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  15. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    International Nuclear Information System (INIS)

    Stein, Jill M.; Brody, Alan S.; Fleck, Robert J.; Walkup, Laura L.; Woods, Jason C.

    2016-01-01

    The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. We conducted a retrospective query of normal CT chest examinations in children ages 0-7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42 ± 27 months). Lung volume ranged 0.10-1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as -380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately -650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of -860 HU as age and lung volume increased. Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. (orig.)

  16. Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    Energy Technology Data Exchange (ETDEWEB)

    Humbert, Ludovic, E-mail: ludohumberto@gmail.com [Galgo Medical, Barcelona 08036 (Spain); Hazrati Marangalou, Javad; Rietbergen, Bert van [Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB (Netherlands); Río Barquero, Luis Miguel del [CETIR Centre Medic, Barcelona 08029 (Spain); Lenthe, G. Harry van [Biomechanics Section, KU Leuven–University of Leuven, Leuven 3001 (Belgium)

    2016-04-15

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm{sup 3}) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm{sup 3}), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm{sup 3}) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm{sup 3}). A trend for the

  17. Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    International Nuclear Information System (INIS)

    Humbert, Ludovic; Hazrati Marangalou, Javad; Rietbergen, Bert van; Río Barquero, Luis Miguel del; Lenthe, G. Harry van

    2016-01-01

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm"3) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm"3), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm"3) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm"3). A trend for the cortical thickness and

  18. Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaowei; Servaes, Sabah; Darge, Kassa [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, The Perelman School of Medicine, Philadelphia, PA (United States); McCullough, William P. [University of Virginia Health System, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Mecca, Patricia [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2016-11-15

    Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens Flash {sup registered} CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDI{sub vol}) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality by

  19. CT classification and clinical significance of rupture globe

    International Nuclear Information System (INIS)

    Diao Jinzhong; Zhang Guixiang

    1998-01-01

    Purpose: To discuss CT appearances of the rupture globe, and CT classifications and their clinical significance. Materials and methods: Forty-nine rupture globes were verified; 79% patents were scanned within 24 hours. Axial plane scanning were done with 3 mm slice and 256 x 256 matrix. Bone and soft tissue conditions were adjusted to analyse the bone and globe structures. Results: CT showed that globe circle rupture in one point of 32%, two points of 20%, and multiple points of 28%. Thickening of globe circle was as follows: 5 mm in 10 globes, 6 mm in 24, and 7 mm in 9.20% injured globes were enlarged and 32% were contracted. 14 anterior chambers deepened more than 4 mm. 83% rupture globes also had intraglobe hemorrhage and 48% foreign bodies. 28% injured globes had exophthalmus, and 75% had injured parasinuses or orbits, or brain trauma. Conclusion: The authors classified the rupture globe into three types. Type III showed unrepaired that should ablate the injured globes, whereas type I and II had to repair and to debride

  20. Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

    Science.gov (United States)

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G.

    2015-01-01

    In x-ray computed tomography (CT), materials having different elemental compositions can be represented by identical pixel values on a CT image (ie, CT numbers), depending on the mass density of the material. Thus, the differentiation and classification of different tissue types and contrast agents can be extremely challenging. In dual-energy CT, an additional attenuation measurement is obtained with a second x-ray spectrum (ie, a second “energy”), allowing the differentiation of multiple materials. Alternatively, this allows quantification of the mass density of two or three materials in a mixture with known elemental composition. Recent advances in the use of energy-resolving, photon-counting detectors for CT imaging suggest the ability to acquire data in multiple energy bins, which is expected to further improve the signal-to-noise ratio for material-specific imaging. In this review, the underlying motivation and physical principles of dual- or multi-energy CT are reviewed and each of the current technical approaches is described. In addition, current and evolving clinical applications are introduced. © RSNA, 2015 PMID:26302388

  1. Cardiac CT for the assessment of chest pain: Imaging techniques and clinical results

    International Nuclear Information System (INIS)

    Becker, Hans-Christoph; Johnson, Thorsten

    2012-01-01

    Immediate and efficient risk stratification and management of patients with acute chest pain in the emergency department is challenging. Traditional management of these patients includes serial ECG, laboratory tests and further on radionuclide perfusion imaging or ECG treadmill testing. Due to the advances of multi-detector CT technology, dedicated coronary CT angiography provides the potential to rapidly and reliably diagnose or exclude acute coronary artery disease. Life-threatening causes of chest pain, such as aortic dissection and pulmonary embolism can simultaneously be assessed with a single scan, sometimes referred to as “triple rule out” scan. With appropriate patient selection, cardiac CT can accurately diagnose heart disease or other sources of chest pain, markedly decrease health care costs, and reliably predict clinical outcomes. This article reviews imaging techniques and clinical results for CT been used to evaluate patients with chest pain entering the emergency department.

  2. Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Akram Al-Ibraheem

    2009-01-01

    Full Text Available 18F-FDG PET plays an increasing role in diagnosis and management planning of head and neck cancer. Hybrid PET/CT has promoted the field of molecular imaging in head and neck cancer. This modality is particular relevant in the head and neck region, given the complex anatomy and variable physiologic FDG uptake patterns. The vast majority of 18F-FDG PET and PET/CT applications in head and neck cancer related to head and neck squamous cell carcinoma. Clinical applications of 18F-FDG PET and PET/CT in head and neck cancer include diagnosis of distant metastases, identification of synchronous 2nd primaries, detection of carcinoma of unknown primary and detection of residual or recurrent disease. Emerging applications are precise delineation of the tumor volume for radiation treatment planning, monitoring treatment, and providing prognostic information. The clinical role of 18F-FDG PET/CT in N0 disease is limited which is in line with findings of other imaging modalities. MRI is usually used for T staging with an intense discussion concerning the preferable imaging modality for regional lymph node staging as PET/CT, MRI, and multi-slice spiral CT are all improving rapidly. Is this review, we summarize recent literature on 18F-FDG PET and PET/CT imaging of head and neck cancer.

  3. Comparative Study of the CT Findings and Clinical Features in Pediatric and Adult Sialadenitis

    International Nuclear Information System (INIS)

    Han, Jong Kyu; Jo, Seong Shik; Kim, Sang Won; Kim, Young Tong; Shin, Hyeong Cheol; Kim, Il Young; Lee, Yong Man

    2010-01-01

    We wanted to compare the CT findings and clinical features of parotitis and submandibular sialadenitis in children and adults and to evaluate the statistical significance of these in different age groups and the usefulness of a CT scan. Ninety-seven adults and 36 pediatric patients with sialadenitis were included in this retrospective study. Regardless of the site of involvement, we evaluated the CT findings and clinical manifestations between the pediatric and adult groups, and between the pediatric and adult parotitis and submandibular sialadenitis groups. At last, all the patients were classified into seven age groups. Abscess formations were more prominent in the parotitis groups, and sialiths were more common in the submandibular sialadenitis group with the lowest incidence in the young children group (≤ 10 years). Cellulitis seen on a CT scan showed a higher incidence in the adult parotitis group, and this finding was closely connected with pain. A number of patients showed cervical lymphadenitis on a CT scan and this coincided with lymph node palpation. Tonsillitis associated sialadenitis was common in the pediatric group. The therapeutic durations were longer in the pediatric parotitis patient group and the adult submandibular sialadenitis group. CT scans were very helpful to evaluate for abscess, stone, lymphadenitis and estimating the associated clinical manifestations such as swelling, palpable lymph nodes, pain with operation and the therapeutic plan

  4. Clinical evaluation of CT discography in the diagnosis of lumbar disc herniation

    International Nuclear Information System (INIS)

    Maehara, Tadayuki; Katsumata, Yasushi; Noda, Masanobu; Tanaka, Mariko; Shirouzu, Ichirou

    1988-01-01

    The CT discographic findings of 56 discs in 43 patients with low-back and/or leg pain were evaluated mainly from the clinical standpoint including pain provocation during the injection of the contrast material, correlation between the type of the herniation and symptoms and clinical course after the examination. The clinical value of CT discography is controversial, but it is well recognized that CT discography is the diagnostic method of choice for equivocal situations as patients showing negative myelography and significant symptoms and for the preoperative evaluation of patient thought to have the extreme lateral disc herniation. Exact provoked pain response was noted in 72 % of 43 pathologic discs and almost all discs especially in patients showing positive SLR test at less than 70 deg. So this pain response seems to provide additional information indicating the true pathologic disc level. Sciatic pain in the legs was much more frequently seen in the paramedian or lateral type herniation, but there was no relation between low-back pain and central type herniation. Majority of either type of disc herniation showed both low-back and leg pains. This suggests that clinical symptoms are based on not only disc herniation but also disc degeneration itself. We injected steroid (4 mg of Decadron) and local anesthetic (1 ml of 1 % Carbocain) into the disc after the examination for the purpose of improving the clinical symptoms as the first attempt. Definite improvement of various degree was noted in 56 % of total 43 cases after the procedure and CT discography was thought to be a valuable method of diagnosis in proper indications despite risky needle puncture. (author)

  5. Thrombophlebitis of the internal jugular vein (Lemierre syndrome) - Clinical and CT findings

    International Nuclear Information System (INIS)

    Kim, Bo Yeon; Yoon, Dae Young; Lim, Kyoung Ja; Seo, Young Lan; Yun, Eun Joo; Choi, Chul Soon; Bae, Sang Hoon; Kim, Hyeong Chul; Kim, Eun Soo; Baek, Sora

    2013-01-01

    Background: Thrombophlebitis of the internal jugular vein (IJV) secondary to neck infection (so-called Lemierre syndrome) is a rare disease. Purpose: To evaluate the clinical and CT findings in patients with thrombophlebitis of the IJV. Material and Methods: The clinical and contrast-enhanced neck CT findings were retrospective analyzed in 10 patients (eight men, two women; mean age, 62.9±8.3 years) with thrombophlebitis of the IJV. Results: Five patients (50%) had complications, including pneumonia (n = 3), neck abscess (n = 1), and thrombophlebitis of cerebral venous sinus (n = 1). All patients, except two who were lost to follow-up, had improved after antibiotics and anticoagulation therapy. Nine (90%) patients had underlying infectious processes in the neck. Contrast-enhanced neck CT of 12 IJVs (five right, three left, and two bilateral) affected by thrombophlebitis demonstrated > 5 cm in length (n = 8, 67%), ovoid shape (n = 7, 58%), complete occlusion of the lumen (n = 10, 83%), circumferential (n = 11, 92%), smooth (n = 8, 67%), and thick (=4 mm) (n = 8, 67%) rim enhancement, and adjacent soft tissue swelling (n = 11, 92%). Conclusion: Contrast-enhanced CT is useful in the diagnosis of thrombophlebitis of the IJV; characteristic CT findings of this unusual entity may be the main clue to the correct diagnosis

  6. The clinical impact of {sup 18}F-FDG PET/CT in extracranial pediatric germ cell tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Adam; Vali, Reza; Marie, Eman; Shammas, Amer [The Hospital for Sick Children and University of Toronto, Department of Medical Imaging, Nuclear Medicine, Toronto, ON (Canada); Shaikh, Furqan [The Hospital for Sick Children and University of Toronto, Division of Haematology and oncology, Toronto, ON (Canada)

    2017-10-15

    Extracranial germ cell tumors are an uncommon pediatric malignancy with limited information on the clinical impact of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the literature. The purpose of this study was to evaluate and compare the clinical impact on management of {sup 18}F-FDG PET/CT with diagnostic computed tomography (CT) in pediatric extracranial germ cell tumor. The list of {sup 18}F-FDG PET/CT performed for extracranial germ cell tumor between May 2007 and November 2015 was obtained from the nuclear medicine database. {sup 18}F-FDG PET/CT and concurrent diagnostic CT were obtained and independently reviewed. Additionally, the patients' charts were reviewed for duration of follow-up and biopsy when available. The impact of {sup 18}F-FDG PET/CT compared with diagnostic CT on staging and patient management was demonstrated by chart review, imaging findings and follow-up studies. During the study period, 9 children (5 males and 4 females; age range: 1.6-17 years, mode age: 14 years) had 11 {sup 18}F-FDG PET/CT studies for the evaluation of germ cell tumor. Diagnostic CTs were available for comparison in 8 patients (10 {sup 18}F-FDG PET/CT studies). The average interval between diagnostic CT and PET/CT was 7.2 days (range: 0-37 days). In total, five lesions concerning for active malignancy were identified on diagnostic CT while seven were identified on PET/CT. Overall, {sup 18}F-FDG PET/CT resulted in a change in management in 3 of the 9 patients (33%). {sup 18}F-FDG PET/CT had a significant impact on the management of pediatric germ cell tumors in this retrospective study. Continued multicenter studies are required secondary to the rarity of this tumor to demonstrate the benefit of {sup 18}F-FDG PET/CT in particular clinical scenarios. (orig.)

  7. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  8. Acoustic neurinoma and posterior fossa meningioma - clinical and CT radiologic findings

    International Nuclear Information System (INIS)

    Catz, A.; Reider-Groswasser, I.; Ichilov Hospital, Tel Aviv; Tel Aviv Univ.

    1986-01-01

    Clinical and computed tomography (CT) findings of twenty-three patients with acoustig neurinoma (AN) and eleven patients with posterior fossa meningioma (PFM) are described. AN frequently (94%) presents with the complaint of hearing loss, while PFM often (60%) presents with non-specific pains in the head or neck. The CT characteristics of AN and PFM in this series were similar to those found in most previous publications. The maximal measured mean diamter of PFM (40.2 mm) was significantly larger than that of AN (26.4 mm). Hydrocephalus was apparently influenced by tumor location rather than by its size. It is concluded that diagnostic ability has been improved in cases of CPA tumors, but not in those of non-CPA PFM, probably because of the earlier clinical presentation of the former. Clinical efforts are still necessary to detect the smaller tumors. (orig.)

  9. Focal breast lesions in clinical CT examinations of the chest. A retrospective analysis; Senologische Befunde bei CT-Untersuchungen des Thorax. Eine retrospektive Auswertung

    Energy Technology Data Exchange (ETDEWEB)

    Krug, Kathrin Barbara; Houbois, Christian; Grinstein, Olga; Borggrefe, Jan; Puesken, Michael; Maintz, David [Cologne Univ. Medical School, Cologne (Germany). Dept. of Diagnostical and Interventional Radiology; Hanstein, Bettina; Malter, Wolfram [Cologne Univ. Medical School, Cologne (Germany). Breast Center and Dept. of Obstetrics and Gynecology; Hellmich, Martin [Cologne Univ. (Germany). Inst. of Medical Statistics, Informatics and Epidemiology

    2017-10-15

    Based on radiological reports, the percentage of breast cancers visualized as incidental findings in routine CT examinations is estimated at ≤2%. In view of the rising number of CT examinations and the high prevalence of breast cancer, it was the goal of the present study to verify the frequency and image morphology of false-negative senological CT findings. All first contrast-enhanced CT examinations of the chest in adult female patients carried out in 2012 were retrospectively included. A senior radiologist systematically assessed the presence of breast lesions on all CT images using the BI-RADS system. All BI-RADS ≥3 notations were evaluated by a second senior radiologist. A consensus was obtained in case of differing BI-RADS assessments. Reference diagnoses were elaborated based on all available clinical, radiological and pathological data. The findings of the CT reports were classified according to the BI-RADS system and were compared with the retrospective consensus findings as well as with the reference diagnoses. The range of indications comprised a broad spectrum including staging and follow-up examinations of solid tumors/lymphoma (N = 701, 59.9 %) and vascular (190, 16.2 %), inflammatory (48, 4.1 %) and pulmonologic (22, 1.9 %) issues. BI-RADS 1/2 classifications were present in 92.5 % and BI-RADS 6 classifications were assessed in 1.7 % of the 1170 included examinations. 68 patients (5.8 %) had at least one lesion retrospectively classified as BI-RADS 3 - 5. The histological potential was known in 57 of these lesions as benign (46, 3.9 %) or malignant (11, 0.9 %). 13 BI-RADS 4/5 consensus assessments (1.1 %) were false-positive. 2 of the 10 lesions classified as being malignant based on the further clinical and radiological course were not mentioned in the written CT reports (0.2 %). Both false-negative CT reports were therapeutically and prognostically irrelevant. The relative frequency of BI-RADS 3 - 5 findings was 5.8 %. It reflects the situation

  10. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P; Hermus, James; Geurts, Mark; Smilowitz, Jennifer

    2015-01-01

    The multi-leaf collimator (MLC) assembly present on TomoTherapy (Accuray, Madison WI) radiation therapy (RT) and mega voltage CT machines is well suited to perform fluence field modulated CT (FFMCT). In addition, there is a demand in the RT environment for FFMCT imaging techniques, specifically volume of interest (VOI) imaging.A clinical TomoTherapy machine was programmed to perform VOI. Four different size ROIs were placed at varying distances from isocenter. Projections intersecting the VOI received ‘full dose’ while those not intersecting the VOI received 30% of the dose (i.e. the incident fluence for non VOI projections was 30% of the incident fluence for projections intersecting the VOI). Additional scans without fluence field modulation were acquired at ‘full’ and 30% dose. The noise (pixel standard deviation) and mean CT number were measured inside the VOI region and compared between the three scans. Dose maps were generated using a dedicated TomoTherapy treatment planning dose calculator.The VOI-FFMCT technique produced an image noise 1.05, 1.00, 1.03, and 1.05 times higher than the ‘full dose’ scan for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region. The VOI-FFMCT technique required a total imaging dose equal to 0.61, 0.69, 0.60, and 0.50 times the ‘full dose’ acquisition dose for ROI sizes of 10 cm, 13 cm, 10 cm, and 6 cm respectively within the VOI region.Noise levels can be almost unchanged within clinically relevant VOIs sizes for RT applications while the integral imaging dose to the patient can be decreased, and/or the image quality in RT can be dramatically increased with no change in dose relative to non-FFMCT RT imaging. The ability to shift dose away from regions unimportant for clinical evaluation in order to improve image quality or reduce imaging dose has been demonstrated. This paper demonstrates that FFMCT can be performed using the MLC on a clinical TomoTherapy machine for the

  11. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  12. CT and MRI evaluation of orbital tumors: our experience

    International Nuclear Information System (INIS)

    Cabrini, Marcelo; Docampo, Jorge; Martinez, Manuel; Bruno, Claudio; Morales, Carlos

    2007-01-01

    Purpose: To show our experience in the evaluation of orbital masses on computed tomography (CT) and magnetic resonance imaging (MRI). To describe their most important findings and epidemiological features found on literature review, related to their differential diagnosis. Materials and methods: During a 48-months period of time, 26 patients (13 male, 13 female; age range, 3 to 75 years) with orbital tumors were evaluated. Seventeen patients underwent MR scans, 8 underwent CT scans, and one underwent both imaging methods. It was employed 0,5 and 1 Tesla MR scanners, and axial-helical CT scanners. Results: Benign lesions were found on 7 patients (cavernous hemangioma [n=2], meningioma [n=1], epidermoid cyst [n=1], dermoid cyst [n=1], lipoma [n=1], orbital vein deformity [n=1]). It was found lesions with undetermined behavior (optical nerve glioma [n=2]), and malignant ones were found on 17 patients (metastatic lesions [n=5], non- Hodgkin's lymphoma [n=3], hemangiopericytoma [n=2], retinoblastoma [n=2], rhabdomyosarcoma [n=2], melanoma [n=1], and lacrimal adenocarcinoma [n=1]). Conclusion: In our experience, 65.4% was malignant tumors (orbital metastasis was the most common; 19.2%). More than one-quarter was benign tumor, where cavernous hemangioma was the most frequent. (author) [es

  13. Clinical application of low-dose CT combined with computer-aided detection in lung cancer screening

    International Nuclear Information System (INIS)

    Xu Zushan; Hou Hongjun; Xu Yan; Ma Daqing

    2010-01-01

    Objective: To investigate the clinical value of chest low-dose CT (LDCT) combined with computer-aided detection (CAD) system for lung cancer screening in high risk population. Methods: Two hundred and nineteen healthy candidates underwent 64-slice LDCT scan. All images were reviewed in consensus by two radiologists with 15 years of thoracic CT diagnosis experience. Then the image data were analyzed with CAD alone. Finally images were reviewed by two radiologists with 5 years of CT diagnosis experience with and without CT Viewer software. The sensitivity, false positive rate of CAD for pulmonary nodule detection were calculated. SPSS 11.5 software and Chi-square test were used for the statistics. Results: Of 219 candidates ,104(47.5% ) were detected with lung nodules. There were 366 true nodules confirmed by the senior radiologists. The CAD system detected 271 (74.0%) true nodules and 424 false-positive nodules. The false-positive rate was 1.94/per case. The two junior radiologists indentifid 292 (79.8%), 286(78.1%) nodules without CAD and 336 (91.8%), 333 (91.0%) nodules with CAD respectively. There were significant differences for radiologists in indentifying nodules with or without CAD system (P<0.01). Conclusions: CAD is more sensitive than radiologists for indentifying the nodules in the central area or in the hilar region of the lung. While radiologists are more sensitive for the peripheral and sub-pleural nodules,or ground glass opacity nodules, or nodules smaller than 4 mm. CAD can not be used alone. The detection rate can be improved with the combination of radiologist and CAD in LDCT screen. (authors)

  14. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  15. Technological features and clinical feasibility of megavoltage CT scanning

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Akanuma, Atsuo; Sakata, Kouichi; Karasawa, Katsuyuki; Terahara, Atsurou; Onogi, Yuzou; Hasezawa, Kenji; Sasaki, Yasuhito

    1992-01-01

    Megavoltage CT scanning using 4-MV and 6-MV radiotherapy beams has been developed and applied to verify errors in patient positioning. A detector system composed of 120 pairs of cadmium tungstate scintillators with photodiodes is mounted to the treatment unit at a distance of 160 cm from the beam source. Image reconstruction is performed with a standard filtered back-projection algorithm. Scanning time and reconstruction time for a slice is approximately 35 s and 60 s respectively. Although spatial resolution is as large as 4 mm, it has sufficient image quality to be applied for treatment planning and verification. The delivered dose with 4 MV and 6 MV is about 1.4 cGy and 2.8 cGy respectively. When a megavoltage CT image is taken in treatment position, the positioning errors are easily detected by comparing it with diagnostic CT sections for treatment planning. Several clinical examples are presented. (orig.)

  16. Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

    International Nuclear Information System (INIS)

    Zhu, Xiaowei; Servaes, Sabah; Darge, Kassa; McCullough, William P.; Mecca, Patricia

    2016-01-01

    Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens Flash "r"e"g"i"s"t"e"r"e"d CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDI_v_o_l) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality

  17. Clinical application of CT-controlled stereotactic aspiration for intracerebral hematoma

    International Nuclear Information System (INIS)

    Chen Weijian; Zhuge Qichuan; Zheng Rongyuan; Guo Xianzhong; Zhong Ming; Wu Jinsen; Qu Xuanxing

    2002-01-01

    Objective: To evaluate the clinical application of CT-controlled stereotactic aspiration for intracerebral hematoma. Methods: CT-guided stereotactic system was installed on the CT bed, and checked against a standard of the coordinate. According to controlled CT scan, the target can be adjusted at any time in the operation. 860 patients with cerebral hematoma underwent CT-controlled stereotactic aspiration. Of the 860 cases, basal ganglion hematoma was present in 408, thalamus and posterior limb of internal capsule hematoma in 136, cerebral lobe hematoma in 261, cerebellar hematoma in 5, ventricular hemorrhage in 10, midbrain and pons hemorrhage in 37, and medulla hemorrhage in 3. Results: Easy drainage of hematoma by aspiration was achieved in 586 cases, stickiness of hematoma with clearing away more than 50% was performed in 202 and less than 50% in 68. The operation duration ranged from 25 to 120 minutes (average 45 minutes). 693 cases survived and 167 cases died. According to the evaluation by active day life (ADL) after 3 months in survivors, ADL 1-2, ADL 3, ADL 4 and ADL 5 results were achieved in 378 cases, 166 cases, 107 cases, and 28 cases, respectively. In addition, 14 cases were lost beyond recall. Conclusion: CT-controlled stereotactic aspiration for intracerebral hematoma is a handy, less invasive, and safe procedure with high accuracy and curative effect, it is worth while popularizing the procedure

  18. The clinical impact of [18F]FDG PET/CT for the management of recurrent endometrial cancer: correlation with clinical and histological findings

    International Nuclear Information System (INIS)

    Chung, Hyun Hoon; Kim, Jae Weon; Park, Noh-Hyun; Song, Yong-Sang; Kang, Soon-Beom; Kang, Won Jun; Chung, June-Key

    2008-01-01

    The purpose of this study was to evaluate the accuracy of integrated positron emission tomography (PET) and computed tomography (CT) for the identification of suspected recurrent endometrial cancer after treatment. Thirty-one women (median age, 53 years) with endometrial cancer treated by primary staging laparotomy who had [ 18 F]fluorodeoxyglucose (FDG) PET/CT performed for suspected recurrence were retrospectively reviewed. The findings of the PET/CT scans were compared, with the histological examination after a surgical biopsy in 20 cases and with clinical follow-up in 11 cases to determine the diagnostic accuracy of PET/CT. Twelve (38.7%) of the 31 patients had a documented recurrence by surgical biopsy or clinical follow-up, and 19 (61.3%) had no evidence of recurrence. Of the 12 patients with recurrent disease, nine (75.0%) women were confirmed to have a recurrence by surgical biopsy. A close correlation was found between the PET/CT and histological or clinical analyses (κ = 0.933, p < 0.001). The overall sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and accuracy of PET/CT were 100, 94.7, 92.3, 100, and 96.8%, respectively. The PET/CT results modified the diagnostic or treatment plan in seven (22.6%) patients, resulting in five (16.1%) patients undergoing previously unplanned therapeutic procedures and eliminating previously planned diagnostic procedures in two (6.5%) patients. Patients with negative PET/CT scans showed significantly better progression-free survival than those with positive scans (p = 0.015). Integrated PET/CT appears to be highly sensitive, specific, and accurate as a post-therapy surveillance modality for endometrial cancer in well-selected patients. The PET/CT might be used to improve patient surveillance and prognosis. (orig.)

  19. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  20. Multiphasic perfusion CT in acute middle cerebral artery ischemic stroke: prediction of final infarct volume and correlation with clinical outcome

    International Nuclear Information System (INIS)

    Yi, Chin A; Na, Dong Gyu; Ryoo, Jae Wook; Moon, Chan Hong; Byun, Hong Sik; Roh, Hong Gee; Moon, Won Jin; Lee, Kwang Ho; Lee, Soo Joo

    2002-01-01

    To assess the utility of multiphasic perfusion CT in the prediction of final infarct volume, and the relationship between lesion volume revealed by CT imaging and clinical outcome in acute ischemic stroke patients who have not undergone thrombolytic therapy. Thirty-five patients underwent multiphasic perfusion CT within six hours of stroke onset. After baseline unenhanced helical CT scanning, contrast-enhanced CT scans were obtained 20, 34, 48, and 62 secs after the injection of 90 mL contrast medium at a rate of 3 mL/sec. CT peak and total perfusion maps were obtained from serial CT images, and the initial lesion volumes revealed by CT were compared with final infarct volumes and clinical scores. Overall, the lesion volumes seen on CT peak perfusion maps correlated most strongly with final infarct volumes (R2=0.819, p<0.001, slope of regression line=1.016), but individual data showed that they were less than final infarct volume in 31.4% of patients. In those who showed early clinical improvement (n=6), final infarct volume tended to be overestimated by CT peak perfusion mapping and only on total perfusion maps was there significant correlation between lesion volume and final infarct volume (R2=0.854, p=0.008). The lesion volumes depicted by CT maps showed moderate correlation with baseline clinical scores and clinical outcomes (R=0.445-0.706, p≤0.007). CT peak perfusion maps demonstrate strong correlation between lesion volume and final infarct volume, and accurately predict final infarct volume in about two-thirds of the 35 patients. The lesion volume seen on CT maps shows moderate correlation with clinical outcome

  1. Community-Acquired Pneumonia Visualized on CT Scans but Not Chest Radiographs: Pathogens, Severity, and Clinical Outcomes.

    Science.gov (United States)

    Upchurch, Cameron P; Grijalva, Carlos G; Wunderink, Richard G; Williams, Derek J; Waterer, Grant W; Anderson, Evan J; Zhu, Yuwei; Hart, Eric M; Carroll, Frank; Bramley, Anna M; Jain, Seema; Edwards, Kathryn M; Self, Wesley H

    2018-03-01

    The clinical significance of pneumonia visualized on CT scan in the setting of a normal chest radiograph is uncertain. In a multicenter prospective surveillance study of adults hospitalized with community-acquired pneumonia (CAP), we compared the presenting clinical features, pathogens present, and outcomes of patients with pneumonia visualized on a CT scan but not on a concurrent chest radiograph (CT-only pneumonia) and those with pneumonia visualized on a chest radiograph. All patients underwent chest radiography; the decision to obtain CT imaging was determined by the treating clinicians. Chest radiographs and CT images were interpreted by study-dedicated thoracic radiologists blinded to the clinical data. The study population included 2,251 adults with CAP; 2,185 patients (97%) had pneumonia visualized on chest radiography, whereas 66 patients (3%) had pneumonia visualized on CT scan but not on concurrent chest radiography. Overall, these patients with CT-only pneumonia had a clinical profile similar to those with pneumonia visualized on chest radiography, including comorbidities, vital signs, hospital length of stay, prevalence of viral (30% vs 26%) and bacterial (12% vs 14%) pathogens, ICU admission (23% vs 21%), use of mechanical ventilation (6% vs 5%), septic shock (5% vs 4%), and inhospital mortality (0 vs 2%). Adults hospitalized with CAP who had radiological evidence of pneumonia on CT scan but not on concurrent chest radiograph had pathogens, disease severity, and outcomes similar to patients who had signs of pneumonia on chest radiography. These findings support using the same management principles for patients with CT-only pneumonia and those with pneumonia seen on chest radiography. Copyright © 2017 American College of Chest Physicians. All rights reserved.

  2. Spinal CT-guided injections. Clinical applications-limitations

    International Nuclear Information System (INIS)

    Stamatakis, V.; Vlachou, I.; Petrocheilou, G.; Safarika, V.; Geroukis, I.; Petinelli, A.; Stathopoulou, S.; Kokkinis, C.

    2012-01-01

    Full text: Introduction: Chronic spinal pain is an important health issue with serious social and financial consequences. Thus, application of minimal invasive procedures is a popular technique for immediate relief of pain. Objectives and tasks: Our purpose is to present CT guided intraspinal injection of pharmaceutical agents for the relief of persistent pain. Material and methods: Chronic localized or radicular spinal pain may be treated safely and efficiently with injection of various pharmaceutical agents (local anesthetic, opioid analgesic and steroids or combination of these). The possible sites of infiltration include: a) intervertebral joints (facets), b) sacroiliac joints, c)perineural infiltration of the affected nerve roots and d) the epidural space. We will mention the patients choice criteria (combination of clinical symptoms and specific pain evaluation questionnaire) as they are reported in the international bibliography. Finally, we will discuss the repeatability criteria of the method as well as its limitations. Results: CT-guided pharmaceutical agents injection for the relief of persistent spinal pain have an advantage against other methods because of the precision and safety that they offer to the localization and diagnosis of the pain cause. Conclusion: Small complications percentage and satisfactory results have made CT-guided spinal injections a popular technique for chronic back pain relief. In order to apply these techniques the good knowledge of the method, its possibilities and limitations is necessary

  3. Virtual non-contrast of liver from dual energy CT: a clinical application

    International Nuclear Information System (INIS)

    Qian Yu'e; Hu Hongjie; Zhang Qiaowei; Hu Peng; Shen Guohui

    2011-01-01

    Objective: To assess the virtual non-contrast liver CT from dual-energy CT for the clinical application. Methods: In total, 51 patients were included in the study, and all patients underwent multi-phase liver CT on a dual-source CT. The True non-contrast liver CT (TNCT) was performed in a single-energy acquisition mode, but the arterial and portovenous liver CT (VNCT) were performed in a dual- energy mode of 110 kV and 140 kV respectively. The virtual non-contrast CT images were derived from the arterial data using liver virtual non-contrast software. Between the true non-contrast CT and the virtual non- contrast CT, the image quality, mean CT HU values in the liver and muscle, signal to noise (SNR), the radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination were compared with t test. Results: There was no significant difference in the detection of' liver lesions between TNCT and VNCT. The CT Hu values of muscle on both TNCT and VNCT images were almost equal. The CT HU values of liver on VNCT images were higher than that on TNCT images and the difference was significant [61.32±6.04 vs. (56.85±4.80) HU, t=-3.927, P<0.01]. There was also significant difference of SNR between TNCT (11.28±2.78) and VNCT (8.65±1.56) images (t=-5.590, P<0.01). The CTDIvol and DLP of single phase were (7.07±0.85) mGy and (155.11± 22.52) mGy · cm respectively in TNCT, and (7.05±0.87) mGy and (154.48±23.12) mGy · cm in VNCT. The total CTDIvol and DLP in VNCT were (14.35±1.66) mGy and (313.91±45.08) mGy · cm respectively, but in TNCT the total CTDIvol and DLP reached (21.43±2.46) mGy and (469.02± 66.22) mGy · cm. The difference of CTDIvol and DLP in single phase between TNCT and VNCT showed no significance, but the total CTDIvol and DLP were significantly different (t=16.168 and 13.132, P< 0.01). Conclusion: With the consequent reduction in radiation dose, the VNCT can replace TNCT as an imaging protocol in multi

  4. The clinical role of "1"8F-FDG PET/CT in diagnosis of the peritoneal carcinomatosis

    International Nuclear Information System (INIS)

    Wang Xiaoyan; Zhang Xiangsong; Chen Zhifeng; Li Ziping; Li Fang; Rao Guohui; Shi Xinchong; Hu Ping

    2010-01-01

    Objective: To evaluate the clinical role of "1"8F-fluorodeoxyglucose (FDG) PET/CT in diagnosis of the peritoneal carcinomatosis. Methods: The "1"8F-FDG PET/CT scan was performed in 22 patients. All had documented malignancy and had ascites. Histopathology. or clinical follow-up was 'gold standard' for diagnostic accuracy in PET/CT scan. Results: Of these 22 patients, 18 had positive "1"8F- FDG PET/CT findings. Sixteen were peritoneal carcinomatosis and 2 were peritoneal tuberculosis. Four patients had negative "1"8F-FDG PET/CT findings. Three were peritonitis and 1 was peritoneal carcinomatosis. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of "1"8F-FDG PET/CT in diagnosing peritoneal carcinomatosis were 94.1% (16/17), 3/5, 88.9% (16/18), 3/4, and 86.4% (19/22). Conclusions: "1"8F-FDG PET/CT had high sensitivity in detecting peritoneal carcinomatosis. The most common false positive for "1"8F-FDG PET/CT in ascites was peritoneal tuberculosis. (authors)

  5. Clinical significance of combined determination of serum BGP, PTH, CT in aged osteoporosis

    International Nuclear Information System (INIS)

    Wang Limin; Chen Kejing; Gu Weiguang; Zhu Weimin; Wang Hongfu

    1997-01-01

    Using radioimmunoassay to determine serum BGP, PTH and CT, the author showed that there are various changes of level of BGP, PTH, CT with respect to osteoporosis of different etiology. It suggested that the combined determination has certain reference value in clinical diagnosis, disease staging and treatment of the aged osteoporosis

  6. Radioisotope cisternographic evaluation of hydrocephalus: Comparison with CT, MRI, and clinical findings

    International Nuclear Information System (INIS)

    Kwon, Soon Tae; Park, Cheong Hee; Kim, Hyeong Yeol; Kim, Dae Hong; Shin, Kyung Suk; Cho, June Sik; Lee, Kang Wook; Kim, Jae Moon

    1993-01-01

    To evaluate the clinical usefulness of radionuclide(RI) cisternography in patients with hydrocephalus, we retrospectively analyzed RI cisternographic findings of 47 patients by using our classification which was modified from Baum's and correlated them with CT(n=37) or MRI(n=10) findings and clinical outcome in selected patients with hydrocephalus(n=37). Modified RI cisternography patterns of 37 patients were type I in three case(8%), type II in seven(18%), type III-A in six(16%), no case of type III-B, type IV-A in 12(32%), and type IV-B in nine(24%). Ri cisternography enabled to differentiate communicating hydrocephalus(27 cases, 73%) from noncommunicating hydrocephalus(10 case, 27%). There was marked clinical improvement in 17 patients(46%), slight improvement in 11 patients(30%), and no improvement in nine patients(24%). The clinical outcome of patients with RI cisternographic type IV-B was worse than that of other types. CT and MRI could neither predict the clinical outcome nor differentiate type IV-B from type IV-A(P>0.05). Ventricular size index(VSI)was significantly higher in patients with type IV than that with other type(p<0.001). RI cisternographic patterns of communicating hydrocephalous were relatively correlated with clinical outcome(r=-0.53, p=.0010 . VIS(r=0.59, p=.001), and dilation of fourth ventricle(r=0.41, p<0.05). We suggest that our modified classification of RI cisternographic patterns can provide more strict physiological assessment of the CFS dynamics and RI cisternography may be still useful to differentiate communicating hydrocephalus from noncommunicating hydrocephalus and to predict the clinical outcome in conjunction with CT/ MR findings and clinical presentation

  7. Evaluation of bone metastases with 18 F- Sodium fluoride PET/CT; initial experience

    International Nuclear Information System (INIS)

    Sanchez C, N.; Serna M, J.A.; Quiroz C, O.; Quinzanos, F.; Valenzuela, J.; Ramirez A, J.L.

    2007-01-01

    The study of NaF-18 PET/CT is the modality with bigger sensitivity and specificity for the bony metastases detection. This additional value of the NaF-18 PET/CT can have a beneficent impact in the clinical handling of the patients with prostate cancer with high risk. (Author)

  8. Clinical analysis of CT features in 200 neonates with hypoxic-ischemic encephalopathy (HIE)

    International Nuclear Information System (INIS)

    Zhang Fan

    2003-01-01

    Objective: To analyze the CT features of HIE in neonates. Methods: CT scanning was performed in 200 neonates with HIE. Results: The CT features in 200 HIE were hypo-attenuated substantia alba, accompanied with intra-cranial hemorrhage, widened cavity of septum pellucidum and cerebral infarction. In total 200 cases, mild HIE was found in 118 cases, moderate HIE was revealed in 67 cases and severe condition was observed in 15 cases. Intra-cranial hemorrhage was noted in 87 cases. Conclusion: The cerebral injury should be diagnosed by the findings of hypo-attenuated substantia alba and intracranial hemorrhage on CT scan, combined with clinical histories and manifestations of intro-uterine neonate asphyxia

  9. Clinical Investigations of a CT-based reconstruction and 3D-Treatment planning system in interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kolotas, C; Zamboglou, N [Strahlenklinik, Stadtische Kliniken Offenbach, Offenbach (Germany)

    1999-12-31

    Purpose: Development, application and evaluation of a CT-guided implantation technique and a fully CT based treatment planning procedure for brachytherapy. Methods and Materials : A brachytherapy procedure based on CT-guided implantation technique and CT based treatment planning has been developed and clinically evaluated. For this purpose a software system (PROMETHEUS) for the 3D reconstruction of brachytherapy catheters and patient anatomy using only CT scans has been developed. An interface for the Nucletron Plato BPS treatment planning system for the optimisation and calculation of dose distribution has been devised. The planning target volume(s) are defined as sets of points using contouring tools and are for optimisation of the 3D dose distribution. Dose-volume histogram-based analysis of the dose distribution enables a clinically realistic evaluation of the brachytherapy application to be made. The CT-guided implantation of catheters and the CT-based treatment planning procedure has been performed for interstitial brachytherapy and for different tumour and anatomical localizations in 197 patients between 1996 and 1997. Results : The accuracy of the CT reconstruction was tested using a quality assurance phantom an an interstitial implant of 12 needles and compared with the results of reconstruction using radiographs[hs. Both methods give comparable results with regard to accuracy. The CT based reconstruction was faster. Clinical feasibility has been proven in pre-irradiated recurrences of brain tumour, in pre-treated recurrences or metastatic disease, and in breast carcinomas. The tumour volume treated ranged from 5.1 - 2741 cm3. Analysis of the implant quality showed a slight significant lower COIN value for the bone implants, but no differences in respect to the planning target volume. Conclusions : With the integration of CT imaging in the treatment planning and documentation of brachytherapy, we have a new CT based quality assurance method to evaluate

  10. Clinical Investigations of a CT-based reconstruction and 3D-Treatment planning system in interstitial brachytherapy

    International Nuclear Information System (INIS)

    Kolotas, C.; Zamboglou, N.

    1998-01-01

    Purpose: Development, application and evaluation of a CT-guided implantation technique and a fully CT based treatment planning procedure for brachytherapy. Methods and Materials : A brachytherapy procedure based on CT-guided implantation technique and CT based treatment planning has been developed and clinically evaluated. For this purpose a software system (PROMETHEUS) for the 3D reconstruction of brachytherapy catheters and patient anatomy using only CT scans has been developed. An interface for the Nucletron Plato BPS treatment planning system for the optimisation and calculation of dose distribution has been devised. The planning target volume(s) are defined as sets of points using contouring tools and are for optimisation of the 3D dose distribution. Dose-volume histogram-based analysis of the dose distribution enables a clinically realistic evaluation of the brachytherapy application to be made. The CT-guided implantation of catheters and the CT-based treatment planning procedure has been performed for interstitial brachytherapy and for different tumour and anatomical localizations in 197 patients between 1996 and 1997. Results : The accuracy of the CT reconstruction was tested using a quality assurance phantom an an interstitial implant of 12 needles and compared with the results of reconstruction using radiographs[hs. Both methods give comparable results with regard to accuracy. The CT based reconstruction was faster. Clinical feasibility has been proven in pre-irradiated recurrences of brain tumour, in pre-treated recurrences or metastatic disease, and in breast carcinomas. The tumour volume treated ranged from 5.1 - 2741 cm3. Analysis of the implant quality showed a slight significant lower COIN value for the bone implants, but no differences in respect to the planning target volume. Conclusions : With the integration of CT imaging in the treatment planning and documentation of brachytherapy, we have a new CT based quality assurance method to evaluate

  11. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    International Nuclear Information System (INIS)

    Okada, Fumito; Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu

    2009-01-01

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  12. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Fumito [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan); Oita University Faculty of Medicine, Department of Radiology, Oita (Japan); Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan)

    2009-04-15

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  13. Diagnostic and prognostic value of asphyxia, Sarnat's clinical classification, and CT-scan in perinatal brain damage

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Toshihide; Wakita, Yoshiharu; Kubonishi, Sakae; Yoshikawa, Seishi (Kochi Prefectural Central Hospital (Japan)); Ito, Toshiyuki; Okada, Yasusuke

    1990-11-01

    A retrospective review was made of 145 babies, excluding those with congenital heart disease or chromosome aberration, admitted for CT scanning. The study was done to determine the diagnostic and prognostic value of CT findings, as well as the presence of asphyxia and the clinical stage based on the Sarnat's classification, in perinatal brain damage. The patients had a minimum follow up of 2 years for the evaluation of neurologic manifestations, such as cerebral palsy, epilepsy and mental retardation. Among babies weighing 2,000 g or more at birth, neonatal asphyxia was significantly correlated with neurologic prognosis. In addition, both clinical stages and CT findings were significantly correlated with neurologic prognosis, irrespective of birth weight. The correlation between clinical stages and CT findings was significant, irrespective of body weight, however, a significant correlation between clinical stages and neonatal asphyxia was restricted to those weighing 2,000 g or more. These findings suggest that the presence of asphyxia, clinical stages and CT findings are complementary in the diagnosis and prognosis evaluation of perinatal brain damage. (N.K.).

  14. High-resolution dynamic imaging and quantitative analysis of lung cancer xenografts in nude mice using clinical PET/CT.

    Science.gov (United States)

    Wang, Ying Yi; Wang, Kai; Xu, Zuo Yu; Song, Yan; Wang, Chu Nan; Zhang, Chong Qing; Sun, Xi Lin; Shen, Bao Zhong

    2017-08-08

    Considering the general application of dedicated small-animal positron emission tomography/computed tomography is limited, an acceptable alternative in many situations might be clinical PET/CT. To estimate the feasibility of using clinical PET/CT with [F-18]-fluoro-2-deoxy-D-glucose for high-resolution dynamic imaging and quantitative analysis of cancer xenografts in nude mice. Dynamic clinical PET/CT scans were performed on xenografts for 60 min after injection with [F-18]-fluoro-2-deoxy-D-glucose. Scans were reconstructed with or without SharpIR method in two phases. And mice were sacrificed to extracting major organs and tumors, using ex vivo γ-counting as a reference. Strikingly, we observed that the image quality and the correlation between the all quantitive data from clinical PET/CT and the ex vivo counting was better with the SharpIR reconstructions than without. Our data demonstrate that clinical PET/CT scanner with SharpIR reconstruction is a valuable tool for imaging small animals in preclinical cancer research, offering dynamic imaging parameters, good image quality and accurate data quatification.

  15. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    Energy Technology Data Exchange (ETDEWEB)

    Horita, Hideki [Jikei Univ., Komae, Tokyo (Japan). Daisan Hospital; Maekawa, Kihei

    1995-09-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2{+-}8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.).

  16. The usefulness of brain MRI and CT in the clinical practice of epilepsia

    International Nuclear Information System (INIS)

    Horita, Hideki; Maekawa, Kihei.

    1995-01-01

    This study was conducted to clarify the usefulness of brain MRI and CT in the clinical practice of epilepsy. The subjects were 100 epileptic child patients (average age, 13.2±8.2 years) who underwent brain MRI, including 93 patients who also underwent brain CT. Twenty-two abnormal findings were obtained by MRI and 25 by CT. Thirty-nine patients who had complications such as mental retardation, cerebral palsy, or the overlapping disorders showed abnormal findings in a significantly high incidence. No significant correlations existed between the presence or absence of abnormal findings and the disease course after seizures. Patients with symptomatic localization-related epilepsies or cryptogenic and symptomatic generalized epilepsies showed abnormal findings in a significantly high incidence and unfavorable disease course after seizures. In 10 of 28 patients who showed abnormal findings, the abnormal finding site on images were correlated to the focus site on electroencephalograms. In conclusion, brain MRI and CT are essential in the clinical practice of epilepsy, however, we should notice the limitation of these methods. (Y.S.)

  17. (18F) FDG PET/CT in patients with fever of unknown origin: AIIMS experience

    International Nuclear Information System (INIS)

    Nazar, A.H.; Naswa, N.; Ramya, S.; Patnecha, M.; Bangkim, Chandra K.H.; Kumar, R.; Bandopadhyay, G.P.; Bal, C.S.; Malhotra, A.

    2010-01-01

    Full text: The aim of this study was to assess the value of ( 18 F) FDG PET/CT in evaluation of patients with Fever of Unknown Origin (FUO). We retrospectively analysed clinical data and ( 18 F) FDG PET scan of 48 patients over a period of 1 year. These patients met the revised definition criteria of FUO (febrile illness of greater than 3 weeks duration, temperature greater than 38.3 C and no diagnosis after appropriate in-patient or out-patient evaluation). Most of the patients recruited in this study had normal clinical and radiological examination. ( 18 F) FDG PET was helpful in making a diagnosis in 24 patients. An infective/inflammatory cause of FUO was found in thirteen (27%) patients, a neoplasm in six (12.5%) patients, autoimmune cause in five (10.4%) patients. A definitive diagnosis could not be made in twenty four (50%) patients. Out of these 24 patients, 15 had normal PET/CT study, 9 had positive PET/CT findings but they lost in follow up and 2 died within 1 month of PET/CT study without any diagnosis. ( 18 F) FDG PET/CT is a useful tool for evaluation of patients with FUO. It provides important diagnostic clues not suggested by other conventional imaging modalities. Patients with positive PET/CT findings but no definitive diagnosis should be followed up further to improve utility of PET/CT

  18. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  19. Clinical application of PET/CT imaging in search of the primary carcinoma

    International Nuclear Information System (INIS)

    Dang Yaping; Liu Gang; Li Miao

    2004-01-01

    Full text: To explore the clinical value of PET/CT scanning in search of the primary carcinoma, we selected 4 patients who were subjected to PET/CT examination during Oct. 2002 to Dec. 2002. The primary lesion in all these patients was not detected. One of them had metastasis to liver, one had metastases in both lungs and the other two were having metastases to the bones. 18F-FDG in doses of 5.55MBq / kg body weight was injected to a fasting patient (at least 6 hours). PET/CT whole body examination was done using Discovery LS-PET/CT (GE Medical System, U.S.A.) 40-60 minutes later. In the first patient with metastasis to liver, primary lesion was localized in the transverse colon near the liver. The PET/CT showed multiple high radioactive uptake lesions of different sizes in the liver. No obvious change in position of the colon uptake was seen on the delayed images. After PET/CT, barium examination showed thinned cavity of the colon near the liver with coarse ankylosis of colon wall just like saw tooth. The mucous membrane was destroyed. Of the two patients with metastases in the bone, first - a 31 years old, was diagnosed to have primary lung cancer with multiple metastases to the liver and the bones. PET/CT showed high radioactive uptake in the inferior left lobe near the hilum with irregular shaped uneven distribution. A round high radioactive uptake area of 1.82 x 1.84 x 1.46cm size was also seen in the right lobe of the liver having clear edge and uneven distribution. The destroyed bones (L-10, L-11, L-12, T-1 and ala ossis i lii) showed high radioactive uptake. Second patient, 57-year male was diagnosed to have malignant lymphoma. PET/CT fusion showed high radioactive uptake in the marrow of whole body. Few destroyed parts of bones were also seen on CT images. Several cervical and the thoracic vertebrae as well as the ninth rib showed irregular radioactive accumulation with clear edges and well-distributed tracer raising the possibility of multiple myeloma or

  20. Clinical manifestations that predict abnormal brain computed tomography (CT in children with minor head injury

    Directory of Open Access Journals (Sweden)

    Nesrin Alharthy

    2015-01-01

    Full Text Available Background: Computed tomography (CT used in pediatric pediatrics brain injury (TBI to ascertain neurological manifestations. Nevertheless, this practice is associated with adverse effects. Reports in the literature suggest incidents of morbidity and mortality in children due to exposure to radiation. Hence, it is found imperative to search for a reliable alternative. Objectives: The aim of this study is to find a reliable clinical alternative to detect an intracranial injury without resorting to the CT. Materials and Methods: Retrospective cross-sectional study was undertaken in patients (1-14 years with blunt head injury and having a Glasgow Coma Scale (GCS of 13-15 who had CT performed on them. Using statistical analysis, the correlation between clinical examination and positive CT manifestation is analyzed for different age-groups and various mechanisms of injury. Results: No statistically significant association between parameteres such as Loss of Consciousness, ′fall′ as mechanism of injury, motor vehicle accidents (MVA, more than two discrete episodes of vomiting and the CT finding of intracranial injury could be noted. Analyzed data have led to believe that GCS of 13 at presentation is the only important clinical predictor of intracranial injury. Conclusion: Retrospective data, small sample size and limited number of factors for assessing clinical manifestation might present constraints on the predictive rule that was derived from this review. Such limitations notwithstanding, the decision to determine which patients should undergo neuroimaging is encouraged to be based on clinical judgments. Further analysis with higher sample sizes may be required to authenticate and validate findings.

  1. Clinical study of 18F-FDG PET/CT whole-body imaging in disseminated carcinoma of unknown primary site

    International Nuclear Information System (INIS)

    Wang Guohui; Liang Peiyan; Cai Yanjun; Zhang Weiguang; Xie Chuanmiao; Wu Peihong

    2008-01-01

    Objective: Carcinoma of unknown primary (CUP) is not uncommon in usual clinical settings. They are, by definition, those cases with clinically suspected primary malignancy but not revealed by conventional investigation. The aim of this study was to investigate the efficacy of whole-body 18 F-fluoro- deoxyglucose (FDG) PET/CT in detecting a primary neoplasm for these patients. Methods: A totle of 150 patients with retrievable records from 169 CUP patients were selected within a group of consecutive 2589 patients from Jan. 2006 to Jun. 2007. All cases underwent whole-body FDG PET/CT scan. The final diagnoses were confirmed by pathologic results, other imaging modalities or clinical follow-up. Results: Among 150 patients, primary tumor sites were successfully detected by whole-body 18 F-FDG PET/CT scan in 70 cases (46.7%), of which 52 were pathologically confirmed and 18 by clinical follow-up. And 38 cases (54.3%) were lung cancer, 8 (11.4%) were nasopharyngeal carcinoma, 13 (18.6%) in digestive sys- tem, and 11 (15.7%) in other systems. Three clinically suspected CUP cases with negative 18 F-FDG PET/ CT were subsequently confirmed of benign processes by clinical follow-up. Six patients were wrongly diagnosed by 18 F-FDG PET/CT, and 15 patients did not have a confirmed diagnosis by the end of research. The primary cause of malignancy after 18 F-FDG PET/CT remained obscure in 56 patients, only 3 of whom be- came known during the course of clinical follow-up (nasopharyngeal bladder and esophageal carcinoma). Conclusion: 18 F-FDG PET/CT whole-body imaging plays an important role in patients with metastatic CUP. (authors)

  2. Sinusitis and intracranial sepsis: the CT imaging and clinical presentation

    International Nuclear Information System (INIS)

    Saxton, V.J.; Boldt, D.W.; Shield, L.K.

    1995-01-01

    The CT imaging and clinical presentation in 14 children with coexistent intracranial sepsis and sinusitis were reviewed. A routine CT head scan (10-mm thick semi-axial slices through the cranium done before and after intravenous contrast medium administration) was found to be an inadequate initial investigation as the intracranial collection was missed in four patients and the abnormal sinuses not shown in six. In half the children the dagnosis of sinusitis was unsuspected at the time of admission. The dominant clinical features were fever, intense headache and facial swelling in early adolescent males. In this clinical setting we recommend: (1) The routine scan is extended through the frontal and ethmoidal sinuses and photographed at a window level and width showing both bone detail and air/soft tissue interfaces; (2) direct coronal projections are performed through the anterior cranial fossa if no collection is seen on the routine study; (3) an early repeat scan within 48 h if the initial study shows no intracranial pathology but the fronto-ethomoidal sinuses are abnormal and there is a high clinical supicion of intracranial sepsis; and (4) in the presence of intracranial sepsis the vault is viewed at bone window settings to exclude cranial osteomyelitis. (orig.)

  3. CT and Clinical Predictors of Fatigue at One Month after Stroke

    Directory of Open Access Journals (Sweden)

    Mansur A. Kutlubaev

    2013-03-01

    Full Text Available Background: Fatigue is a common and distressing consequence of stroke, and the aetiology of post-stroke fatigue (PSF is poorly understood. It is unclear whether chronic brain changes [cerebral atrophy and white matter lesions (WML], stroke lesion location or certain clinical features are related to its development. The aim of this study was to identify, in patients with acute stroke, whether features in different brain regions on routine CT imaging or routinely collected clinical features predicted PSF at 1 month. Methods: In total, 107 patients (62% male with acute ischaemic or haemorrhagic stroke were assessed for fatigue (Fatigue Assessment Scale, anxiety and depression (Hospital Anxiety and Depression Scale at 1 month. Admission brain CT was rated using a structured scoring system for (i severity of atrophy and (ii severity of WML in different regions of the brain, and (iii site of acute and previous vascular lesions. Results: Cerebral atrophy of mild or greater severity was present in 84 patients (77.5% and WML of mild or greater severity was present in 54 patients (50.5% in at least one of the evaluated brain regions. There was no association between PSF and severity of atrophy or WML, or presence of acute or previous vascular lesions. We used the Oxfordshire Community Stroke Project (OCSP classification to explore the possible influence of lesion location because a minority of the patients (37.4% had visible acute lesions. Fatigue scores were higher in patients with clinically diagnosed posterior strokes (p = 0.046, in females (p = 0.05 and in those with higher depression and anxiety scores (ρ = 0.52; p 2 = 0.254. Stroke subtype (according to the OCSP classification was marginally predictive (β = 0.17; p = 0.05 and sex was not statistically significant (β = 0.15; p = 0.08. Conclusions: Features on routine post-stroke CT do not appear to associate with fatigue at 1 month. However, clinically diagnosed posterior strokes as well as female

  4. Thyroid Incidentalomas on 18F-FDG PET/CT: Clinical Significance and Controversies

    Directory of Open Access Journals (Sweden)

    William Makis

    2017-10-01

    Full Text Available Objective: The purpose of the current study is to examine the incidence and clinical significance of unexpected focal uptake of 18F-fluorodeoxyglucose (18F-FDG on positron emission tomography/computed tomography (PET/CT in the thyroid gland of oncology patients, the maximum standardized uptake value (SUVmax of benign and malignant thyroid incidentalomas in these patients, and review the literature. Methods: Seven thousand two hundred fifty-two 18F-FDG PET/CT studies performed over four years, were retrospectively reviewed. Studies with incidental focal 18F-FDG uptake in the thyroid gland were further analyzed. Results: Incidental focal thyroid 18F-FDG uptake was identified in 157 of 7252 patients (2.2%. Sufficient follow-up data (≥12 months were available in 128 patients, of whom 57 (45% had a biopsy performed and 71 had clinical follow-up. Malignancy was diagnosed in 14 of 128 patients (10.9%. There was a statistically significant difference between the median SUVmax of benign thyroid incidentalomas (SUVmax 4.8 vs malignant (SUVmax 6.3, but the wide range of overlap between the two groups yielded no clinically useful SUVmax threshold value to determine malignancy. Conclusion: 18F-FDG positive focal thyroid incidentalomas occurred in 2.2% of oncologic PET/CT scans, and were malignant in 10.9% of 128 patients. This is the lowest reported malignancy rate in a North American study to date, and significantly lower than the average malignancy rate (35% reported in the literature. Invasive biopsy of all 18F-FDG positive thyroid incidentalomas, as recommended by some studies, is unwarranted and further research to determine optimal management is needed. There was no clinically useful SUVmax cut-off value to determine malignancy and PET/CT may not be a useful imaging modality to follow these patients conservatively.

  5. The clinical utility of FDG PET/CT among solid organ transplant recipients suspected of malignancy or infection

    International Nuclear Information System (INIS)

    Wareham, Neval E.; Lundgren, J.D.; Cunha-Bang, C. da; Sengeloev, H.; Gustafsson, F.; Iversen, M.; Johannesen, H.H.; Kjaer, A.; Fischer, B.M.; Rasmussen, A.; Soerensen, S.S.

    2017-01-01

    Solid organ transplant (SOT) recipients are at high risk of developing infections and malignancies. 18 F-FDG PET/CT may enable timely detection of these diseases and help to ensure early intervention. We aimed to describe the clinical utility of FDG PET/CT in consecutive, diagnostic unresolved SOT recipients transplanted from January 2004 to May 2015. Recipients with a post-transplant FDG PET/CT performed as part of diagnostic work-up were included. Detailed chart reviews were done to extract relevant clinical information and determine the final diagnosis related to the FDG PET/CT. Based on a priori defined criteria and the final diagnosis, results from each scan were classified as true or false, and diagnostic values determined. Among the 1,814 recipients in the cohort, 145 had an FDG PET/CT performed; 122 under the indication of diagnostically unresolved symptoms with a suspicion of malignancy or infection. The remaining (N = 23) had an FDG PET/CT to follow-up on a known disease or to stage a known malignancy. The 122 recipients underwent a total of 133 FDG PET/CT scans performed for a suspected malignancy (66 %) or an infection (34 %). Sensitivity, specificity, and positive and negative predictive values of the FDG PET/CT in diagnosing these conditions were 97, 84, 87, and 96 %, respectively. FDG PET/CT is an accurate diagnostic tool for the work-up of diagnostic unresolved SOT recipients suspected of malignancy or infection. The high sensitivity and NPV underlines the potential usefulness of PET/CT for excluding malignancy or focal infections in this often complex clinical situation. (orig.)

  6. A study on correlation between CT findings and clinical course of meningitis in children

    International Nuclear Information System (INIS)

    Song, Chi Sung; Chang, Kee Hyun; Yeon, Kyung Mo; Hwang, Yong Seung

    1984-01-01

    63 cases of meningitis in children were reviewed to study correlated between brain CT findings and clinical course. We divided 63 cases into 3 groups according to clinical course, that is , Group I: Healed without significant sequelae. Group II: Discharged with sequelae such as neurologic deficit or complicated clinical course. Group III: Expired or considered to be expired after hopeless discharge. The CT findings were retrospectively analyzed and compared with each clinical group. We drawed several conclusions as follows: 1. The wrost prognostic CT findings is dirty basal cisternal enhancement. ( Group I only 5%, Group II 50%, Group III 45%). 2. Focal brain parenchymal lesion, especially multiple, such as granuloma and infarct shows unfavorable clinical outcome, that is , high rate of Group III and evident neurologic deficit, in contrast to only 7% of Group I. 3. In 7 case of which CT findings is only hydrocephalus, the prognosis is rather favorable, that is 57% were Group I, 43% were improved after V-P shunt (Group II) and no Group III. But hydrocephalus with dirty cisternal enhancement results in grave prognosis, that is, Group I only 8%, Group II 54%, Group III 38%. With regard to overall hydrocephalus, predilection for good or bad prognosis can't be mentioned. 4. No prognostic difference were noted between presence and absence of periventricular low density in hydrocephalus. 5. CSF pressure of hydrocephalus is mostly high (over 20 cm H 2 O), but normal pressure hydrocephalus were noted in 24%. CSF pressure of normal ventricle size is mostly under 18 cm H 2 O but high pressure were noted in 18 % of the normal sized ventricle (most of them shows intracranial space occupying lesion such as granuloma, accute infarct, subdural effusion, etc). 6. Most of diffuse brain swelling, diffuse brain atrophy and subdural effusion result in Group I , that is , favorable clinical outcome. 7. Normal CT findings are found in 29%, of which 61% belong to Group I and 31% to Group

  7. CT and clinical study for intratumoral gas formation in post transarterial embolization of hepatoma and renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Katsuragi, M; Matsuo, N; Yoshikawa, K [Nara Medical Univ., Kashihara (Japan)

    1982-09-01

    Thirty-two patients with hepatocellular carcinoma and six patients with renal cell carcinoma for whom the arterial embolization therapy was performed were studied by CT and clinical follow-up for investigating intratumoral gas detected on CT in post-embolization cases. The intratumoral air was found by CT in seven patients with hepatocellular carcinoma and four patients with renal cell carcinoma. The air was composed of a collection of multiple small round gas bubbles in the embolized tumor except in one case where it formed a serpiginous pattern. There was no hematologic nor clinical evidence of liver abscess in all the cases. It was possible to distinguish gas from abscess or fat by a combination of CT and clinical findings.

  8. Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Woussen, S.; Vanbeckevoort, D.; Bosmans, H.; Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Lopez-Rendon, X.; Zanca, F. [University Hospitals Leuven, Department of Imaging and Pathology, Leuven (Belgium)

    2016-04-15

    To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. (orig.)

  9. Lymphoplasmacytic sclerosing cholangitis: assessment of clinical, CT, and pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, S., E-mail: shigekimiyo@luck.ocn.ne.j [Department of Technical Radiology, Nagoya University School of Health Sciences, Nagoya (Japan); Nagasaka, T. [Department of Pathology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Suzuki, K.; Satake, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2009-11-15

    Aim: To assess the clinical, computed tomography (CT), and pathological findings in patients with lymphoplasmacytic sclerosing cholangitis. Materials and methods: Fifteen consecutive patients (four women and 11 men, mean age 71 years) with lymphoplasmacytic sclerosing cholangitis and without the characteristic features of underlying disorders causing benign biliary strictures were retrospectively recruited. Two radiologists evaluated multiphase contrast-enhanced CT images acquired with 0.5 or 1-mm collimation. One pathologist performed all histological examinations, including IgG4 immunostaining. Results: The intrahepatic biliary ducts showed dilatation in all 15 patients, but only seven presented with jaundice. Although laboratory data were not available in all patients, serum gammaglobulin and IgG levels were elevated in five of six patients and six of eight patients, respectively. Anti-nuclear antibody was detected in three of six patients. The involved biliary ducts showed the following CT findings: involvement of the hilar biliary duct (14/15), a mean wall thickness of 4.9 mm, a smooth margin (10/15), a narrow but visible lumen (6/15), hyper-attenuation during the late arterial phase (9/15), homogeneous hyper-attenuation during the delayed phase (11/11), and no vascular invasion (14/15). Abnormal findings in the pancreas and urinary tract were detected in eight of 15 patients. In 13 patients with adequate specimens, moderate to severe lymphoplasmacytic infiltration associated with dense fibrosis was observed. Infiltration of IgG4-positive plasma cells was moderate or severe in nine patients and minimal or absent in four patients. Conclusion: Lymphoplasmacytic sclerosing cholangitis exhibits relatively characteristic clinical and CT findings, although they are not sufficiently specific for differentiation from other biliary diseases.

  10. Lymphoplasmacytic sclerosing cholangitis: assessment of clinical, CT, and pathological findings

    International Nuclear Information System (INIS)

    Itoh, S.; Nagasaka, T.; Suzuki, K.; Satake, H.; Ota, T.; Naganawa, S.

    2009-01-01

    Aim: To assess the clinical, computed tomography (CT), and pathological findings in patients with lymphoplasmacytic sclerosing cholangitis. Materials and methods: Fifteen consecutive patients (four women and 11 men, mean age 71 years) with lymphoplasmacytic sclerosing cholangitis and without the characteristic features of underlying disorders causing benign biliary strictures were retrospectively recruited. Two radiologists evaluated multiphase contrast-enhanced CT images acquired with 0.5 or 1-mm collimation. One pathologist performed all histological examinations, including IgG4 immunostaining. Results: The intrahepatic biliary ducts showed dilatation in all 15 patients, but only seven presented with jaundice. Although laboratory data were not available in all patients, serum gammaglobulin and IgG levels were elevated in five of six patients and six of eight patients, respectively. Anti-nuclear antibody was detected in three of six patients. The involved biliary ducts showed the following CT findings: involvement of the hilar biliary duct (14/15), a mean wall thickness of 4.9 mm, a smooth margin (10/15), a narrow but visible lumen (6/15), hyper-attenuation during the late arterial phase (9/15), homogeneous hyper-attenuation during the delayed phase (11/11), and no vascular invasion (14/15). Abnormal findings in the pancreas and urinary tract were detected in eight of 15 patients. In 13 patients with adequate specimens, moderate to severe lymphoplasmacytic infiltration associated with dense fibrosis was observed. Infiltration of IgG4-positive plasma cells was moderate or severe in nine patients and minimal or absent in four patients. Conclusion: Lymphoplasmacytic sclerosing cholangitis exhibits relatively characteristic clinical and CT findings, although they are not sufficiently specific for differentiation from other biliary diseases.

  11. Perlappendiceal inflammatory masses: CT-directed management and clinical outcome in 70 patients

    International Nuclear Information System (INIS)

    Jeffrey, R.B. Jr.; Tolentino, C.S.; Federle, M.P.

    1987-01-01

    The clinical outcome was reviewed in 70 patients with CT evidence of periappendiceal inflammatory masses. Thirty-two patients had either phlegmons or small abscesses (less than 3 cm). These patients were initially treated with antibiotic therapy alone, with resolution of the inflammatory process in 28 of the patients (88%). Twenty-eight patients underwent percutaneous abscess drainage of periappendiceal abscesses that was successful in 26 patients (93%). Although 13 patients (46%) had low-output fistulas communicating with the cecum, 12 of 13 closed with 2 weeks of drainage. Ten patients had early surgical drainage for extensive, poorly defined abscesses. Based on CT, a rational approach can be chosen to reduce morbidity and optimize clinical outcome

  12. Early experience with a picture archiving and communication system for X-ray CT

    International Nuclear Information System (INIS)

    Nakano, Y.; Komori, M.; Minato, K.

    1987-01-01

    A network using fiberoptic ring architecture has been implemented to connect an x-ray CT unit with an image work station and optical disk storage unit. The work station has three noninterlaced cathode-ray tube (CRT) monitors of 1,024 X 1,024 pixels. The optical disk system stores 32 optical disk cartridges (2.6 Gbytes per cartridge). A general-purpose interface bus is used for communication between the CT unit and the network interface unit. Transfer time from CT to interface unit is 40 kbyte/second, 5 seconds per image. On-line data acquisition, long-term archiving, and CT interpretation using CRTs have been tested and the system has been working for 3 months in a clinical environment

  13. Value of integrated PET/CT in clinical staging of patients with lung cancer

    International Nuclear Information System (INIS)

    Zhao Jun; Guan Yihui; Zuo Chuantao; Hua Fengchun; Lin Xiangtong

    2004-01-01

    Objectives: The purpose of this study was to evaluate the value of combined fluorine-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) in patients with lung cancer, and to compare the results of PET/CT with those of FDG PET and CT alone. Methods: Forty-two patients were studied in this group. 3D whole body images were acquired using Siemens Biograph Sensetionl6 PET/CT scanner. Attenuation corrected PET images, CT and fusion images were interpreted. Reports were compared for each patient including identified the number of lesions, their anatomical localization and certainty of diagnosis. Results: PET/CT increased the number of lesions reported as being definitely abnormal or normal (+22%). In 12 patients (28.6%), the PET/CT report positively impacted surgical management when compared to the PET report alone. 6 patients were correctly downstaged negating further treatment or imaging, 3 patient was upstaged to inoperable and in another 3 ones improved localization by PET/CT led to an altered surgical incision with decreased morbidity. Lesion-based evaluation showed sensitivity for regional lymph node involvement of 61% for CT alone, 88% for FDG PET alone, and 96% for integrated PET/CT imaging respectively. In addition, PET/CT could identify some benign disease, including lung tuberculosis, cyst of liver and kidney, calculus etc. Conclusion: PET/CT improves anatomical localization and increases the certainty in reporting abnormal and normal lesions. PET/CT imaging is superior to CT alone and has additional benefit over FDG PET alone, and is accurate in clinical staging for lung cancer. (authors)

  14. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.; Klinische Neuroanatomie - kranielle MRT und CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanfermann, Heinrich; Raab, Peter [Medizinische Hochschule Hannover (MHH) (Germany). Inst. fuer Diagnostische und Interventionelle Neuroradiologie; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-07-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  15. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by 18F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    International Nuclear Information System (INIS)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni; Schillaci, Orazio; Calabria, Ferdinando

    2011-01-01

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. 18 F-FDG positron emission tomography/computed tomography ( 18 F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV max ) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV max value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  16. SIMulation of Medication Error induced by Clinical Trial drug labeling: the SIMME-CT study.

    Science.gov (United States)

    Dollinger, Cecile; Schwiertz, Vérane; Sarfati, Laura; Gourc-Berthod, Chloé; Guédat, Marie-Gabrielle; Alloux, Céline; Vantard, Nicolas; Gauthier, Noémie; He, Sophie; Kiouris, Elena; Caffin, Anne-Gaelle; Bernard, Delphine; Ranchon, Florence; Rioufol, Catherine

    2016-06-01

    To assess the impact of investigational drug labels on the risk of medication error in drug dispensing. A simulation-based learning program focusing on investigational drug dispensing was conducted. The study was undertaken in an Investigational Drugs Dispensing Unit of a University Hospital of Lyon, France. Sixty-three pharmacy workers (pharmacists, residents, technicians or students) were enrolled. Ten risk factors were selected concerning label information or the risk of confusion with another clinical trial. Each risk factor was scored independently out of 5: the higher the score, the greater the risk of error. From 400 labels analyzed, two groups were selected for the dispensing simulation: 27 labels with high risk (score ≥3) and 27 with low risk (score ≤2). Each question in the learning program was displayed as a simulated clinical trial prescription. Medication error was defined as at least one erroneous answer (i.e. error in drug dispensing). For each question, response times were collected. High-risk investigational drug labels correlated with medication error and slower response time. Error rates were significantly 5.5-fold higher for high-risk series. Error frequency was not significantly affected by occupational category or experience in clinical trials. SIMME-CT is the first simulation-based learning tool to focus on investigational drug labels as a risk factor for medication error. SIMME-CT was also used as a training tool for staff involved in clinical research, to develop medication error risk awareness and to validate competence in continuing medical education. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  17. Blunt bowel and mesenteric trauma: role of clinical signs along with CT findings in patients' management.

    Science.gov (United States)

    Firetto, Maria Cristina; Sala, Francesco; Petrini, Marcello; Lemos, Alessandro A; Canini, Tiberio; Magnone, Stefano; Fornoni, Gianluca; Cortinovis, Ivan; Sironi, Sandro; Biondetti, Pietro R

    2018-04-27

    Bowel and/or mesentery injuries represent the third most common injury among patients with blunt abdominal trauma. Delayed diagnosis increases morbidity and mortality. The aim of our study was to evaluate the role of clinical signs along with CT findings as predictors of early surgical repair. Between March 2014 and February 2017, charts and CT scans of consecutive patients treated for blunt abdominal trauma in two different trauma centers were reread by two experienced radiologists. We included all adult patients who underwent contrast-enhanced CT of the abdomen and pelvis with CT findings of blunt bowel and/or mesenteric injury (BBMI). We divided CT findings into two groups: the first included three highly specific CT signs and the second included six less specific CT signs indicated as "minor CT findings." The presence of abdominal guarding and/or abdominal pain was considered as "clinical signs." Reference standards included surgically proven BBMI and clinical follow-up. Association was evaluated by the chi-square test. A logistic regression model was used to estimate odds ratio (OR) and confidence intervals (CI). Thirty-four (4.1%) out of 831 patients who sustained blunt abdominal trauma had BBMI at CT. Twenty-one out of thirty-four patients (61.8%) underwent surgical repair; the remaining 13 were treated conservatively. Free fluid had a significant statistical association with surgery (p = 0.0044). The presence of three or more minor CT findings was statistically associated with surgery (OR = 8.1; 95% CI, 1.2-53.7). Abdominal guarding along with bowel wall discontinuity and extraluminal air had the highest positive predictive value (100 and 83.3%, respectively). In patients without solid organ injury (SOI), the presence of free fluid along with abdominal guarding and three or more "minor CT findings" is a significant predictor of early surgical repair. The association of bowel wall discontinuity with extraluminal air warrants exploratory laparotomy.

  18. The role of CT-guided percutaneous drainage of loculated air collections: an institutional experience.

    Science.gov (United States)

    Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A

    2015-10-01

    The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.

  19. The clinical utility of FDG PET/CT among solid organ transplant recipients suspected of malignancy or infection

    Energy Technology Data Exchange (ETDEWEB)

    Wareham, Neval E.; Lundgren, J.D. [Rigshospitalet, Centre for Health and Infectious Disease Research (CHIP), Department of Infectious Diseases, Copenhagen (Denmark); Cunha-Bang, C. da; Sengeloev, H. [Rigshospitalet, Department of Haematology, Copenhagen (Denmark); Gustafsson, F.; Iversen, M. [Rigshospitalet, Department of Cardiology, Copenhagen (Denmark); Johannesen, H.H.; Kjaer, A.; Fischer, B.M. [Rigshospitalet, Department of Clinical Physiology, Nuclear Medicine and PET, Copenhagen (Denmark); Rasmussen, A. [Rigshospitalet, Department of Surgical Gastroenterology, Copenhagen (Denmark); Soerensen, S.S. [Rigshospitalet, Department of Nephrology, Copenhagen (Denmark)

    2017-03-15

    Solid organ transplant (SOT) recipients are at high risk of developing infections and malignancies. {sup 18}F-FDG PET/CT may enable timely detection of these diseases and help to ensure early intervention. We aimed to describe the clinical utility of FDG PET/CT in consecutive, diagnostic unresolved SOT recipients transplanted from January 2004 to May 2015. Recipients with a post-transplant FDG PET/CT performed as part of diagnostic work-up were included. Detailed chart reviews were done to extract relevant clinical information and determine the final diagnosis related to the FDG PET/CT. Based on a priori defined criteria and the final diagnosis, results from each scan were classified as true or false, and diagnostic values determined. Among the 1,814 recipients in the cohort, 145 had an FDG PET/CT performed; 122 under the indication of diagnostically unresolved symptoms with a suspicion of malignancy or infection. The remaining (N = 23) had an FDG PET/CT to follow-up on a known disease or to stage a known malignancy. The 122 recipients underwent a total of 133 FDG PET/CT scans performed for a suspected malignancy (66 %) or an infection (34 %). Sensitivity, specificity, and positive and negative predictive values of the FDG PET/CT in diagnosing these conditions were 97, 84, 87, and 96 %, respectively. FDG PET/CT is an accurate diagnostic tool for the work-up of diagnostic unresolved SOT recipients suspected of malignancy or infection. The high sensitivity and NPV underlines the potential usefulness of PET/CT for excluding malignancy or focal infections in this often complex clinical situation. (orig.)

  20. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    International Nuclear Information System (INIS)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  1. Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Eun; Lee, Joon Woo; Kim, Joo Hyung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Gyeonggi-do (Korea, Republic of); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Gyeonggi-do (Korea, Republic of)

    2011-04-15

    Sacroplasty for sacral insufficiency fractures (SIFs) has been performed mostly under computed tomography (CT) or fluoroscopy guidance. The purposes of this study are to describe technical tips and clinical outcomes of sacroplasty under C-arm flat panel detector CT (C-arm CT) guidance, and to compare the cement distributions shown on C-arm CT with those on multi-detector CT (MDCT). This study consisted of patients who underwent sacroplasty for SIF using C-arm CT from May 2006 to May 2009. Technical success was assessed in terms of cement filling and leakage. Clinical outcome was assessed at short-term (less than 1 month) and long-term (more than 1 month) follow-up using a four-grade patient satisfaction scale: poor, fair, good, and excellent. After sacroplasty, all patients underwent MDCT and three radiologists compared MDCT images with C-arm CT images in consensus, focusing on the cement distribution and cement leakage. Sacroplasties were performed on both sacral alae in all 8 patients (male:female = 2:6, mean age = 76.9, range = 63-82). The technical success rate was 100%. At short-term follow up, 6 patients (87.5%) reported significant improvement. Five patients (62.5%) were available for long-term follow-up and all 5 patients reported a reduced pain and an improved ability to ambulate. Using MDCT as the standard of reference, the cement distribution was visualized equally well by C-arm CT. Sacroplasty under C-arm CT showed excellent technical success and good clinical outcome. There was an excellent correlation between C-arm CT and MDCT in evaluating cement distribution and cement leakage. (orig.)

  2. Thrombus length discrepancy on dual-phase CT can predict clinical outcome in acute ischemic stroke

    International Nuclear Information System (INIS)

    Park, Mina; Kim, Kyung-eun; Lee, Seung-Koo; Shin, Na-Young; Lim, Soo Mee; Song, Dongbeom; Heo, Ji Hoe; Kim, Jin Woo; Oh, Se Won

    2016-01-01

    The thrombus length may be overestimated on early arterial computed tomography angiography (CTA) depending on the collateral status. We evaluated the value of a grading system based on the thrombus length discrepancy on dual-phase CT in outcome prediction. Forty-eight acute ischemic stroke patients with M1 occlusion were included. Dual-phase CT protocol encompassed non-contrast enhanced CT, CTA with a bolus tracking technique, and delayed contrast enhanced CT (CECT) performed 40s after contrast injection. The thrombus length discrepancy between CTA and CECT was graded by using a three-point scale: G0 = no difference; G1 = no difference in thrombus length, but in attenuation distal to thrombus; G2 = difference in thrombus length. Univariate and multivariate analyses were performed to define independent predictors of poor clinical outcome at 3 months. The thrombus discrepancy grade showed significant linear relationships with both the collateral status (P = 0.008) and the presence of antegrade flow on DSA (P = 0.010) with good interobserver agreement (κ = 0.868). In a multivariate model, the presence of thrombus length discrepancy (G2) was an independent predictor of poor clinical outcome [odds ratio = 11.474 (1.350-97.547); P =0.025]. The presence of thrombus length discrepancy on dual-phase CT may be a useful predictor of unfavourable clinical outcome in acute M1 occlusion patients. (orig.)

  3. Short- and long-term effects of clinical audits on compliance with procedures in CT scanning.

    Science.gov (United States)

    Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2016-08-01

    To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.

  4. Clinical application of early PET-CT imaging after radiofrequency ablation of liver neoplasms

    International Nuclear Information System (INIS)

    Liu Zhaoyu; Chang Zhihui; Lu Zaiming; Xin Jun; Wang Xiaoming; Guo Qiyong

    2009-01-01

    Objective: To evaluate the application of early 18 F-FDG PET-CT imaging after radiofrequency ablation (RFA) of hepatic malignancies. Methods: Fifteen patients with liver tumors (five hepatocellular carcinoma, ten colorectal cancer liver metastasis) underwent RFA as part of clinical management. The lesions were all hypermetabolic on PET-CT performed within 2 weeks prior to RFA. All subjects underwent 18 F-FDG PET-CT (early PET-CT) within 24 hours after RFA. Total photopenia, focal uptake, and rim-shaped uptake were regarded as complete ablation, residual tumor, and inflammation, respectively. Follow-up PET-CT scans were performed as the reference standard. Results: Twelve patients showed total photopenia at the ablation site on the early PET-CT scan, and in all of these patients, total photopenia at the ablation sites was seen on the follow-up PET-CT scans. Two patients had focal uptake at the ablation sites on the early PET-CT scan, and both of these foci increased in size and intensity, which were compatible with residual tumors at the time of ablation. Only one patient had rim-shaped uptake on the early PET-CT scan. The rim-shaped uptake disappeared on PET-CT performed 3 months later, which indicated the nature of inflammation. Conclusions: There is infrequent inflammatory uptake at the RFA site of liver tumors on 18 F-FDG PET-CT if scanning is performed within 24 hours after ablation. Thus, early PET- CT has the potential to evaluate the efficacy of an RFA procedure by indicating tumor-free as total photopenia and residual tumors as focal uptake. (authors)

  5. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  6. CT image and clinical analysis of the term neonatal hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Zhan Zhigang; Zheng Keguo

    2006-01-01

    Objective: This is a retrospective investigation of 87 cases of perinatal HIE diagnosed in Junan hospital with literature review, made to improve the diagnosis of HIE, and provide objective information as well as the principle for clinical management and prognosis. Methods: In total 87 patients with HIE, including 52 males and 25 females, aged from 38 weeks to 42 weeks, underwent examination in 1 hour to 16 days after the delivery. There was natural labor in 39 cases, vacuum labor in 11 cases, forceps delivery in 9 cases, abdominal delivery in 6 cases. All the neonatal infants had a history of asphyxia on different levels. Results: CT scan showed diffuse or asymmetrical hypodense shadows with poorly-defined border, where the CT value measured between 10-18 HU, accompanying with the displacement or even absence of lateral ventricle. Subarachnoid hemorrhage (SAH) were found in 34 cases (39.5%), parenchyma hemorrhage in 24 cases (27.6%), intraventricular hemorrhage (IVH) in 15 cases (17.2%), and subdural hemorrhage in 5 cases (5.7%). Additionally, scalp turgidity was seen in 11 cases, and skull fracture in 4 cases as well. Conclusion: The CT scan shows the anoxicasphyxial lesions in the brain resulting from asphyxiation in neonatal, and the severity is rated with CT manifestation and brain edema, which provide objective guidance of the prognosis and the clinical management of HIE. (authors)

  7. Clinical application of subtraction CT imaging for evaluation of pulmonary vascular permeability

    International Nuclear Information System (INIS)

    Kato, Shiro; Asai, Toshihiko; Yatagai, Shigeo; Oonuma, Noboru; Ohno, Kunihiko; Nakamoto, Takaaki; Iizuka, Masahiko

    1991-01-01

    In this clinical study, one normal subject, one patient with primary interstitial pneumonia, one patient with segmental pneumonia due to Staphylococcus aureus, one patient with post-operative esophageal carcinoma, and two patients with mitral stenosis were studied. Dynamic CT scan images under continuous injection of low osmotic contrast medium were analyzed in series, in an attempt to evaluate vascular permeability quantitatively. The following results were obtained. Subtraction CT scan image 10 minutes after the start of contrast medium injection in two patients with pneumonia, showed a reduction of pulmonary vascular permeability following therapy. Subtraction CT scan image of the patient with post-operative esophageal carcinoma treated with 25 Gy radiation showed a discrepancy between pulmonary vascular permeability and other findings. In hemodynamically stable patients with mitral stenosis, subtraction CT images demonstrated that pulmonary vascular permeability was not affected by pulmonary congestion, irrespective of its severity. (author)

  8. Serial CT and MRI of ischaemic cerebral infarcts: frequency and clinical impact of haemorrhagic transformation

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, T.E.; Brueckmann, H. [Muenchen Univ. (Germany). Abt. fuer Neuroradiologie; Schulte-Altedorneburg, G. [Dept. of Radiology/Neuroradiology, University Medical School of Luebeck (Germany); Droste, D.W. [Dept. of Neurology, University Medical School of Luebeck (Germany)

    2000-04-01

    The frequency, predisposing factors and clinical consequences of haemorrhagic infarcts and damaged blood-brain barrier as shown by contrast enhancement (CE) in ischaemic cerebral infarcts are controversial. We prospectively compared the sensitivity of CT and MRI to haemorrhagic transformation (HT) and CE. We also wished to investigate the clinical significance of HT and factors possibly associated with it. We studied 36 patients with acute ischaemic infarcts in the middle cerebral artery territory during the first 2 weeks after the ictus. After CT and rating of the neurological deficit on admission, serial examinations with clinical neuromonitoring, contrast-enhanced CT and MRI were done on the same day. The occurrence and severity of HT were correlated with CE, stroke mechanism, infarct size, development of neurological deficits and antithrombotic treatment. The frequency of HT detected by MRI was 80 %. CE usually preceded HT or was seen simultaneously. MRI had a higher sensitivity than CT to HT and CE. Severity of HT was positively correlated with infarct size (P < 0.01). HT had no influence on patient's neurological status. Neither the type of antithrombotic treatment nor the stroke mechanism was associated with the severity of HT. No parenchymal haemorrhage occurred. (orig.)

  9. Comparing the use of SNOMED CT and ICD10 for coding clinical conditions to implement laboratory guidelines.

    Science.gov (United States)

    Yasini, Mobin; Ebrahiminia, Vahid; Duclos, Catherine; Venot, Alain; Lamy, Jean-Baptiste

    2013-01-01

    Laboratory medicine is responsible for an important part of hospital expenditure. Providing appropriate decision support to laboratory test requesters at the point of care is one of the main incentives for implementing laboratory guidelines, which can improve medical care. Laboratory guidelines developed by local experts in the Parisian region and two national guidelines for dyslipidemia were analyzed to extract test ordering recommendations. Clinical conditions which can be a trigger to order or not to order laboratory tests were extracted and mapped with ICD10 and SNOMED CT: 43.1% of clinical conditions were matched by ICD10 whereas SNOMED CT covered 80.1% of these conditions. For the non-mapped conditions, the main problem was found to be the ambiguity of the terms used in the guidelines. Ordinal characteristics of some clinical conditions and using terms more specific than SNOMED CT were other causes of mapping failure. Applying consistent and explicit concepts in the development of guidelines would lead to better implementation. By resolving the guideline ambiguity, SNOMED CT is a good choice and covers almost all of the clinical conditions in laboratory guidelines which are needed to implement in a Clinical Decision Support System.

  10. Acute intramural hematoma of ascending aorta. CT findings and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Toshio; Sakuyama, Keiko; Hiekata, Tomizou; Yamanaka, Ikuo [St. Marianna Univ., Kanagawa (Japan). Yokohama Seibu Hospital; Kuroki, Kazunori; Ohyama, Yukio; Ishikawa, Tohru; Kawada, Tadanori; Akashi, Katsuya

    1997-12-01

    The purpose of this study was to describe the CT findings and clinical outcomes of nineteen patients with acute intramural hematoma (IMH) of the ascending aorta. Six patients underwent surgery on the emergency basis (3 patients) due to cardiac tamponade (n=2) and dilated aorta (n=1), and on the elective basis (3 patients) due to patent and enlarging false lumen. Among the 13 patients with medical management, four patients died from complications of IMH during the follow-up period (2 days-2.5 years). Transition to aortic dissection or enlargement of an intimal tear was noted in 5 patients (31%) in 1 to 6 weeks after onset. Three patients died of causes not related to IMH. Six patients had been alive 2 to 9 years after onset. Retrospective review revealed 10 patients (53%) as possible surgical candidates, and the other 9 patients as medically treated patients in the long-term follow-up. The surgical group showed cardiac tamponade or shock in 6 patients on admission and had pericardial effusion in all the patients on the initial CT scan. In the patients with acute IMH of the ascending aorta, surgery should be considered for severe clinical symptoms, pericardial effusion and large size of the ascending aorta (more than 4 cm) on CT scan, and for converting to a typical type A aortic dissection. CT scan had a major role in making an early diagnosis, in depicting a dangerous sign, and in monitoring its progression or resolution of IMH. (author)

  11. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  12. SU-E-J-35: Clinical Performance Evaluation of a Phase II Proton CT Scanner

    International Nuclear Information System (INIS)

    Mandapaka, A; Ghebremedhin, A; Farley, D; Giacometti, V; Vence, N; Bashkirov, V; Patyal, B; Schulte, R; Plautz, T; Zatserklyaniy, A; Johnson, R; Sadrozinski, H

    2014-01-01

    Purpose: To develop the methodology to evaluate the clinical performance of a Phase II Proton CT scanner Methods: Range errors on the order of 3%-5% constitute a major uncertainty in current charged particle treatment planning based on Hounsfield Unit (HU)-relative stopping power (RSP) calibration curves. Within our proton CT collaboration, we previously developed and built a Phase I proton CT scanner that provided a sensitive area of 9 cm (axial) × 18 cm (in-plane). This scanner served to get initial experience with this new treatment planning tool and to incorporate lessons learned into the next generation design. A Phase II scanner was recently completed and is now undergoing initial performance testing. It will increase the proton acquisition rate and provide a larger detection area of 9 cm x 36 cm. We are now designing a comprehensive evaluation program to test the image quality, imaging dose, and range uncertainty associated with this scanner. The testing will be performed along the lines of AAPM TG 66. Results: In our discussion of the evaluation protocol we identified the following priorities. The image quality of proton CT images, in particular spatial resolution and low-density contrast discrimination, will be evaluated with the Catphan600 phantom. Initial testing showed that the Catphan uniformity phantom did not provide sufficient uniformity; it was thus replaced by a cylindrical water phantom. The imaging dose will be tested with a Catphan dose module, and compared to a typical cone beam CT dose for comparable image quality. Lastly, we developed a dedicated dosimetry range phantom based on the CIRS pediatric head phantom HN715. Conclusion: A formal evaluation of proton CT as a new tool for proton treatment planning is an important task. The availability of the new Phase II proton CT scanner will allow us to perform this task. This research is supported by the National Institute of Biomedical Imaging and Bioengineering of the NIH under award number R01

  13. Differential diagnosis of truly suprasellar space-occupying masses: synopsis of clinical findings, CT, and MRI

    International Nuclear Information System (INIS)

    Reul, J.; Weis, J.; Spetzger, U.; Isensee, C.; Thron, A.

    1995-01-01

    This review demonstrates the features of truly suprasellar masses in modern imaging based on the clinical, CT, and MRI findings of 42 patients with suprasellar masses in correlation to the histologic findings. The radiologic examinations were evaluated retrospectively to determine if diagnosis can be made based on specific imaging patterns. The most frequent clinical findings of space-occupying suprasellar masses were visual disturbances, diabetes insipidus, and symptoms and signs of occlusive hydrocephalus. There were no clinical features specific for any of the observed masses. Craniopharyngiomas were the most frequent tumors. They appeared in two different forms, as cystic and as solid enhancing masses. The cystic tumors could not be differentiated from cystic hamartomas or cystic gliomas by CT or MRI. The solid craniopharyngiomas were similar to meningiomas and hamartomas. In craniopharyngiomas of adults calcifications were not common. In CT and especially in MRI gliomas were characterized by the diffuse infiltration of the adjacent brain tissue or optic nerve. Except for meningiomas, all lesions were highly variable in appearance, making a reliable characterization by CT and MRI difficult in many cases. However, administration of contrast media in some cases resulted in a better tumor delineation. Compared with unenhanced MRI the enhanced scans did not increase diagnostic efficacy for neoplasms, but were helpful in the differentiation from inflammatory diseases. The MRI technique was superior to CT in demonstrating the anatomic relationships, thus facilitating evaluation of origin and extent of the lesions. The CT technique, of course, was more reliable in the detection of calcifications. Both CT and MRI are not tissue-specific, however, and suprasellar tumors as well as many other neoplasms cannot be classified using only one of these imaging techniques. (orig.)

  14. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  15. Our experience in using the whole body computed tomography unit (GE CT/T)

    International Nuclear Information System (INIS)

    Murakawa, Yasuhiro; Morimoto, Mitsuo; Ishigaki, Naoya; Zaitsu, Hiroaki; Kawabata, Kohji

    1983-01-01

    Since our hospital installed the CT unit of the head and neck (SCT-100N) in April, 1979, we reported our experience in using this equipment in 1980 and 1982. After that, since the whole body CT unit (GE CT/T) was installed in our hospital in April, 1982, the total number of CT examination have reached approximately three thousand five handred till this August. Consequently, this CT image seemed to be superior in image quality to that obtained by other CT equipment. The most important characteristic of this equipment is that the retrospective and prospective reviews of the target image and the coronal and sagittal recontruction from contiguous transverse axial scans are possible. We show in this report two experimental CT photograms obtained by the reviews of the target image in using of microchart phantom and CT photograms of uterus myoma, metastatic thyroid and liver cancers and further, of contiguous transverse axial scans of cerebral embolism and the coronal recontruction. The important problems for the future of this equipment are those of absorbed X-ray dose of the patients and the scan time. (author)

  16. Short- and long-term effects of clinical audits on compliance with procedures in CT scanning

    International Nuclear Information System (INIS)

    Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2016-01-01

    To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific ''paediatric brain CT'' procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. (orig.)

  17. Five Years of Cyclotron Radioisotope Production Experiences at the First PET-CT in Venezuela

    International Nuclear Information System (INIS)

    Colmenter, L.; Coelho, D.; Esteves, L. M.; Ruiz, N.; Morales, L.; Lugo, I.; Sajo-Bohus, L.; Liendo, J. A.; Greaves, E. D.; Barros, H.; Castillo, J.

    2007-01-01

    Five years operation of a compact cyclotron installed at PET-CT facility in Caracas, Venezuela is given. Production rate of 18 F labeled FDG, operation and radiation monitoring experience are included. We conclude that 18 FDG CT-PET is the most effective technique for patient diagnosis

  18. The clinical significance of CT in the preoperative diagnosis of colon and rectal cancer

    International Nuclear Information System (INIS)

    Itano, Satoshi; Fuchimoto, Sadanori; Hamada, Fumihiro; Kimura, Takanobu; Orita, Kunzo

    1986-01-01

    The clinical significance of CT in the preoperative diagnosis of colon and rectal cancer was studied. Thirty four patients were investigated in this series. The diagnostic criteria of the CT examination were previously established in a study of wall invasion (S factor), lymph node metastasis (N factor), liver metastasis (H factor) and peritoneal dissemination (P factor). The CT diagnosis was done prospectively according to these criteria, and the CT diagnosis was compared with the macroscopic and histological diagnosis. The accuracy of the prospective diagnosis as to H, S, N and P factors was 79.4 %, 55.9 %, 41.2 % and 20.6 %, respectively. The diagnostic value of CT seemed to be acceptable as to the H factor, but limited to some extent to the S and N factors. (author)

  19. Creation of a 3D printed temporal bone model from clinical CT data.

    Science.gov (United States)

    Cohen, Joss; Reyes, Samuel A

    2015-01-01

    Generate and describe the process of creating a 3D printed, rapid prototype temporal bone model from clinical quality CT images. We describe a technique to create an accurate, alterable, and reproducible rapid prototype temporal bone model using freely available software to segment clinical CT data and generate three different 3D models composed of ABS plastic. Each model was evaluated based on the appearance and size of anatomical structures and response to surgical drilling. Mastoid air cells had retained scaffolding material in the initial versions. This required modifying the model to allow drainage of the scaffolding material. External auditory canal dimensions were similar to those measured from the clinical data. Malleus, incus, oval window, round window, promontory, horizontal semicircular canal, and mastoid segment of the facial nerve canal were identified in all models. The stapes was only partially formed in two models and absent in the third. Qualitative feel of the ABS plastic was softer than bone. The pate produced by drilling was similar to bone dust when appropriate irrigation was used. We present a rapid prototype temporal bone model made based on clinical CT data using 3D printing technology. The model can be made quickly and inexpensively enough to have potential applications for educational training. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  1. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  2. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  3. FDG PET and CT in locally advanced adenocarcinomas of the distal oesophagus. Clinical relevance of a discordant PET finding

    International Nuclear Information System (INIS)

    Stahl, A.; Wieder, H.; Schwaiger, M.; Weber, W.A.; Stollfuss, J.; Ott, K.; Fink, U.

    2005-01-01

    Aim: the incidence of adenocarcinomas of the distal oesophagus (ADE) has dramatically increased in Western countries. The clinical importance of a FDG PET finding discordant with CT was determined in patients with locally advanced ADE. In addition, tumour standardized uptake values (SUV) were correlated with patient survival. Patients, methods: 40 consecutive patients were analyzed retrospectively. All patients underwent an attenuation corrected FDG PET scan (neck, chest, abdomen) and contrast enhanced helical CT of the chest and abdomen. PET and CT scans were reviewed independently and concomitantly with respect to metastases in predefined lymph node sites and organs. Any discordance between PET and CT was assessed for clinical relevance. Clinical relevance was defined as a change in the overall therapeutic concept (curative vs. palliative). Follow-up imaging and histological evaluation served as the gold standard. Mean tumour SUVs were determined by 1.5 cm regions of interest placed over the tumour's maximum. Results: when read independently from the CT scan FDG PET indicated a clinically relevant change in tumour stage in 9/40 patients (23%) and a non-relevant change in 11/40 patients (28%). PET was correct in 5/9 patients (56%) with clinically relevant discordances. In 4/9 patients PET was incorrect (3 false positive due to suspicion of MI-lymph nodes or lung metastases, 1 false negative in disseminated liver metastases). With concomitant reading, PET indicated a clinically relevant change in tumour stage in 6/40 patients (15%) and a non-relevant change in 5/40 patients (13%). PET was correct in 5/6 patients (83%) with clinically relevant discordances. The patient with disseminated liver disease remained the single false negative. Overall, the benefit from PET was based on its higher diagnostic accuracy at organ sites. Tumour SUV did not correlate with patient survival. Conclusion: about half of discordances between FDG PET and CT are clinically relevant

  4. Computer-aided detection in CT colonography: initial clinical experience using a prototype system

    International Nuclear Information System (INIS)

    Graser, A.; Geisbuesch, S.; Reiser, M.F.; Becker, C.R.; Kolligs, F.T.; Schaefer, C.; Mang, T.

    2007-01-01

    Computer-aided detection (CAD) algorithms help to detect colonic polyps at CT colonography (CTC). The purpose of this study was to evaluate the accuracy of CAD versus an expert reader in CTC. One hundred forty individuals (67 men, 73 women; mean age, 59 years) underwent screening 64-MDCT colonography after full cathartic bowel cleansing without fecal tagging. One expert reader interpreted supine and prone scans using a 3D workstation with integrated CAD used as ''second reader.'' The system's sensitivity for the detection of polyps, the number of false-positive findings, and its running time were evaluated. Polyps were classified as small (≤5 mm), medium (6-9 mm), and large (≥10 mm). A total of 118 polyps (small, 85; medium, 19; large, 14) were found in 56 patients. CAD detected 72 polyps (61%) with an average of 2.2 false-positives. Sensitivity was 51% (43/85) for small, 90% (17/19) for medium, and 86% (12/14) for large polyps. For all polyps, per-patient sensitivity was 89% (50/56) for the radiologist and 73% (41/56) for CAD. For large and medium polyps, per-patient sensitivity was 100% for the radiologist, and 96% for CAD. In conclusion, CAD shows high sensitivity in the detection of clinically significant polyps with acceptable false-positive rates. (orig.)

  5. The correlation of preoperative CT, MR imaging, and clinical staging (FIGO) with histopathology findings in primary cervical carcinoma

    International Nuclear Information System (INIS)

    Oezsarlak, Oe.; Schepens, E.; Corthouts, B.; Beeck, B.O. de; Parizel, P.M.; De Schepper, A.M.; Tjalma, W.; Marck, E. van

    2003-01-01

    The aim of this study was to compare the preoperative findings of abdominal/pelvic CT and MRI with the preoperative clinical International Federation of Obstetrics and Gynecology (FIGO) staging and postoperative pathology report in patients with primary cancer of the cervix. Thirty-six patients with surgical-pathological proven primary cancer of the cervix were retrospectively studied for preoperative staging by clinical examination, CT, and MR imaging. Studied parameters for preoperative staging were the presence of tumor, tumor extension into the parametrial tissue, pelvic wall, adjacent organs, and lymph nodes. The CT was performed in 32 patients and MRI (T1- and T2-weighted images) in 29 patients. The CT and MR staging were based on the FIGO staging system. Results were compared with histological findings. The group is consisted of stage 0 (in situ):1, Ia:1, Ib:8, IIa:2, IIb:12, IIIa:4, IVa:6, and IVb:2 patients. The overall accuracy of staging for clinical examination, CT, and MRI was 47, 53, and 86%, respectively. The MRI incorrectly staged 2 patients and did not visualize only two tumors; one was an in situ (stage-0) and one stage-Ia (microscopic) disease. The MRI is more accurate than CT and they are both superior to clinical examination in evaluating the locoregional extension and preoperative staging of primary cancer of the cervix. (orig.)

  6. The usefulness of CT scanning in clinical observation on the patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Golebiowski, M.; Barcikowska, M.; Pfeffer-Baczuk, A.; Luczywek, E.

    1994-01-01

    On the basis of brain CT studies of 150 patients of the clinic for persons with Alzheimer's disease the diagnostic utility of measurement of hippocampal fissure and craniocerebral ratios was assessed. In analyzed group hippocampal fissure measurements greater than 4 mm occurred only in patients with symptoms of Alzheimer's type dementia. The measurement showed 90% sensitivity and 70% specificity as the prognostic factor of clinical course, especially at the first part of the disease. The evaluation of the hippocampal fissure in conjunction with detailed analysis of CT picture of the atrophic brain allowed for precise final diagnosis. (author)

  7. Essential requirements of a CT colonography service

    International Nuclear Information System (INIS)

    Hansmann, Anika; Burling, David

    2013-01-01

    There are many potential challenges to developing a high quality, efficient CT colonography service. Some are clear and predictable, for example creating CT capacity and securing financial resources, but some are less obvious, such as harnessing local support or changing referral practice amongst clinical colleagues. Notwithstanding, such barriers will need to be overcome to deliver a well-resourced, successful CT colonography programme. This article utilises the authors’ experience of developing their own CT colonography service from scratch (now examining >1200 patients per annum) and relevant published articles on ‘Standards’ of practice and training to recommend how others might provide CT colonography in their own patient communities. We offer a practical guide and will emphasise the need for a multi-disciplinary approach with locally agreed protocols and service objectives

  8. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  9. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  10. CT colonography without cathartic preparation: positive predictive value and patient experience in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Zueco Zueco, Carmen; Sobrido Sampedro, Carolina; Corroto, Juan D.; Rodriguez Fernandez, Paula; Fontanillo Fontanillo, Manuela [Complexo Hospitalario Universitario de Vigo - CHUVI, Vigo, Pontevedra (Spain)

    2012-06-15

    To determine the positive predictive value (PPV) for polyps {>=}6 mm detected at CT colonography (CTC) performed without cathartic preparation, with low-dose iodine faecal tagging regimen and to evaluate patient experience. 1920 average-risk patients underwent CTC without cathartic preparation. Faecal tagging was performed by diatrizoate meglumine and diatrizoate sodium at a total dose of 60 ml (22.2 g of iodine).The standard interpretation method was primary 3D with 2D problem solving. We calculated per-patient and per-polyp PPV in relation to size and morphology. All colonic segments were evaluated for image quality (faecal tagging, amount of liquid and solid residual faeces and luminal distension). Patients completed a questionnaire before and after CTC to assess preparation and examination experience. Per-polyp PPV for detected lesions of {>=}6 mm, 6-9 mm, {>=}10 mm and {>=}30 mm were 94.3%, 93.1%, 94.7% and 98%, respectively. Per-polyp PPV, according to lesion morphology, was 94.6%, 97.3% and 85.1% for sessile, pedunculated and flat polyps, respectively. Per-patient PPV was 92.8%. Preparation without frank cathartics was reported to cause minimal discomfort by 78.9% of patients. CTC without cathartic preparation and low-dose iodine faecal tagging may yield high PPVs for lesions {>=}6 mm and is well accepted by patients. circle Computed tomographic colonography (CTC) without cathartic preparation is well accepted by patients circle Cathartic-free faecal tagging CTC yields high positive predictive values circle CTC without cathartic preparation could improve uptake of colorectal cancer screening. (orig.)

  11. Pulmonary spheral tuberculosis: features and clinical significance of spiral dynamic CT

    International Nuclear Information System (INIS)

    Xie Ruming; Ma Daqing; Li Tieyi; Chen Yi; Lu Fudong; Zhou Xinhua

    2001-01-01

    Objective: To assess the features and clinical significance of spiral dynamic CT in patients with pulmonary spheral tuberculosis. Methods: The 54 foci in 42 patients with pulmonary spheral tuberculosis were studied. Thin-sections at 2 mm thickness and 2 mm interval through the nodular center were obtained before and after administration of contrast material. Results: In 54 pulmonary spheral tuberculosis, maximum enhanced CT value in 51 (94.4%, 51/54) foci was less than 20 HU, and more than 20 HU in the other 3(5.6%, 3/54) foci. 27(50.0%, 27/54) foci showed no any enhancement, 24, (44%, 24/54) foci showed capsular enhancement, 1(1.9%, 1/54) focus showed peripheral enhancement and 2(3.7%, 2/54) foci showed extensive enhancement. The accuracy of the correct diagnosis was 25.9% in terms of plain CT and 94.4% in terms of enhanced CT scanning. The difference was significant (x 2 = 50.1, P < 0.05). The curative effect of extensive enhanced foci and peripheral enhanced foci was optimal, capsular enhanced foci was second, and non-enhanced foci was barely satisfactory. Conclusion: Spiral dynamic CT technique may improve the accuracy of diagnosing pulmonary spheral tuberculosis. No enhancement and/or capsular enhancement were suggestive of tuberculosis. The enhancing character of foci might contribute to assess the curative effect of anti-tuberculosis

  12. Percutaneous CT-guided interventional procedures in musculoskeletal system (our experience)

    Energy Technology Data Exchange (ETDEWEB)

    Thanos, Loukas E-mail: loutharad@yahoo.com; Mylona, Sophia; Kalioras, Vasilios; Pomoni, Maria; Batakis, Nikolaos

    2004-06-01

    Percutaneous interventional procedures include a broad spectrum of minimal invasive techniques, which are a useful diagnostic and therapeutic tool. In this study we present our experience in CT-guided percutaneous musculoskeletal biopsies, drainages of musculoskeletal abscesses, facet and sacroiliac joint injection and radiofrequency thermal ablation of painful metastases or osteoid osteomas.

  13. Pediatric chest CT after trauma: impact on surgical and clinical management

    International Nuclear Information System (INIS)

    Patel, Rina P.; Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H.; Yu, Chang; Ray, Jackie

    2010-01-01

    Chest CT after pediatric trauma is frequently performed but its clinical impact, particularly with respect to surgical intervention, has not been adequately evaluated. To assess the impact of chest CT compared with chest radiography on pediatric trauma management. Two hundred thirty-five consecutive pediatric trauma patients who had both chest CT and radiography were identified. Images were reviewed and findings were categorized and correlated with subsequent chest interventions, blinded to final outcome and management. Of the 235 children, 38.3% (90/235) had an abnormal chest radiograph and 63.8% (150/235) had an abnormal chest CT (P < 0.0001). Chest interventions followed in 4.7% (11/235); of these, the findings could be made 1 cm above the dome of the liver in 91% (10/11). Findings requiring chest intervention included pneumothorax (PTX) and vertebral fractures. PTX was found on 2.1% (5/235) of chest radiographs and 20.0% (47/235) of chest CTs (P < 0.0001); 1.7% (4/235) of the children received a chest tube for PTX, 0.85% (2/235) seen on chest CT only. Vertebral fractures were present in 3.8% of the children (9/235) and 66.7% (6/9) of those cases were treated with spinal fusion or brace. There were no instances of mediastinal vascular injury. Most intrathoracic findings requiring surgical management in our population were identified in the lower chest and would be included in routine abdominopelvic CT exams; this information needs to be taken into consideration in the diagnostic algorithm of pediatric trauma patients. (orig.)

  14. Pediatric chest CT after trauma: impact on surgical and clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rina P. [Vanderbilt University School of Medicine, Nashville, TN (United States); Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H. [Vanderbilt University, Department of Radiology and Radiological Sciences, Vanderbilt Children' s Hospital, Nashville, TN (United States); Yu, Chang [Vanderbilt University, Department of Biostatistics, Nashville, TN (United States); Ray, Jackie [Vanderbilt University, Department of Pediatric Surgery, Vanderbilt Children' s Hospital, Nashville, TN (United States)

    2010-07-15

    Chest CT after pediatric trauma is frequently performed but its clinical impact, particularly with respect to surgical intervention, has not been adequately evaluated. To assess the impact of chest CT compared with chest radiography on pediatric trauma management. Two hundred thirty-five consecutive pediatric trauma patients who had both chest CT and radiography were identified. Images were reviewed and findings were categorized and correlated with subsequent chest interventions, blinded to final outcome and management. Of the 235 children, 38.3% (90/235) had an abnormal chest radiograph and 63.8% (150/235) had an abnormal chest CT (P < 0.0001). Chest interventions followed in 4.7% (11/235); of these, the findings could be made 1 cm above the dome of the liver in 91% (10/11). Findings requiring chest intervention included pneumothorax (PTX) and vertebral fractures. PTX was found on 2.1% (5/235) of chest radiographs and 20.0% (47/235) of chest CTs (P < 0.0001); 1.7% (4/235) of the children received a chest tube for PTX, 0.85% (2/235) seen on chest CT only. Vertebral fractures were present in 3.8% of the children (9/235) and 66.7% (6/9) of those cases were treated with spinal fusion or brace. There were no instances of mediastinal vascular injury. Most intrathoracic findings requiring surgical management in our population were identified in the lower chest and would be included in routine abdominopelvic CT exams; this information needs to be taken into consideration in the diagnostic algorithm of pediatric trauma patients. (orig.)

  15. Clinical investigation of fatty liver by CT

    International Nuclear Information System (INIS)

    Kato, Katsumoto; Takayama, Tetsuo; Sano, Hiroshi; Katada, Naoyuki; Takeichi, Masayuki

    1984-01-01

    CT findings of 56 cases of diffuse fatty infiltration comfirmed by liver biopsy were investigated and compared with those of chronic hepatitis and liver cirrhosis. We found that the diagnosis of severe fatty infiltration (fatty liver) can be specifically possible when the ratios of CT values of liver to those of spleen are less than 0.85 and it is reasonable criterion for diagnosis of fatty liver by CT. This criterion was satisfied by 197 studies (2.9%), 169 cases with fatty liver (diffuse: 141 cases, focal: 28 cases) of 6800 CT studies of liver. Obesity, diabetes and alcohol abuse were main causative factors in both diffuse and focal fatty liver. The percentage of cases showing no abnormal results in blood chemistry tests was great compared with the previous report based on liver biopsy. The changes of CT values of liver faithfully reflected the improvement of each causal factor and reciprocal changes were observed between diffuse and focal fatty liver in repeated CT examination. So, CT is useful in estimating the effect of treatment as well as in diagnosis of fatty liver. Focal fatty liver is temporary manifestation during the proscess of development or improvement of fatty liver. (author)

  16. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lanfermann, Heinrich; Raab, Peter; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-01-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  17. Clinical application of the helical CT in patients who are unable to hold their breath

    International Nuclear Information System (INIS)

    Toyama, Yoshihiro; Kimura, Naruhide; Ohkawa, Motoomi; Tanabe, Masatada.

    1997-01-01

    We performed helical CT in eighteen patients who were unable to hold their breath for 10 chest and 8 abdominal regions. Although there were respiratory artifacts in three cases, we could obtain the useful clinical information in all cases. In our experimental examinations, CT value of the phantom by helical scan was lower than that by conventional scan without movement of the phantom. With movement of it, the CT value was further lowered by either scan method, but the lowered rate was smaller by helical scan as the movement becomes faster. We consider that helical CT can be applied to patients who were unable to hold their breath. (author)

  18. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee

    2009-01-01

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  19. Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea); Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun [University of Ulsan College of Medicine, Department of Pediatric Cardiac Surgery, Asan Medical Center, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [University of Ulsan College of Medicine, Department of Pediatric Cardiology, Asan Medical Center, Seoul (Korea)

    2009-03-15

    In patients with congenital heart disease, coronary artery anomalies are common and have different clinical importance from individuals with structurally normal hearts. Visibility of the coronary arteries by CT has markedly improved due to high temporal resolution and ECG-synchronized data acquisition. In this article we describe current multislice CT techniques for coronary artery imaging and illustrate coronary artery anomalies and clinically important coronary artery anatomy from the point of view of congenital heart disease. (orig.)

  20. Analogue experiment of the crustal deformation by X-ray CT; X sen CT wo mochiita chikaku no henkei no analogue jikken

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Y.; Shi, B; Murakami, Y. [Geological Survey of Japan, Tsukuba (Japan)

    1997-05-27

    This paper reports a predictive result on a deformation experiment on sand beds using an X-ray computerized tomography (CT) equipment. The X-ray CT is a method to perform the following processes: X-rays are irradiated on a sample; decayed intensity data are measured along ray paths of the permeated X-rays; the data are inverted by using the Fourier transform; and spatial distribution of the coefficient of X-ray absorption inside the sample is acquired as a gray scale image. The deformation experiment was carried by putting sand into an acrylic container to a depth of 2 cm and manually pressing a plate in the horizontal direction. Sand blocks make a relative motion along a specific plane when they are deformed, but it was not possible to recognize faults clearly by naked eyes. Upon completion of the deformation, the experimental device was placed on the CT equipment to acquire images of the two-dimensional cross section. The higher the X-ray absorption coefficient, the brighter the picture elements. It can be seen that three inversed faults have been imaged clearly. Therefore, this equipment was verified usable as an effective observation equipment for an analogue deformation experiment. 4 refs., 2 figs.

  1. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by {sup 18}F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Masala, Salvatore; Bartolucci, Alberto D.; Mammucari, Matteo; Simonetti, Giovanni [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); Schillaci, Orazio; Calabria, Ferdinando [University Hospital Tor Vergata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy); I.R.C.C.S. Neuromed, Department of Nuclear Medicine and Neuroradiology, Pozzilli (Italy); Policlinico Tor Vegata, Department of Diagnostic and Molecular Imaging, Interventional Radiology and Radiotherapy, Rome (Italy)

    2011-02-15

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. {sup 18}F-FDG positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) is a single technique of imaging that provides in a ''single step'' both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV{sub max}) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV{sub max} value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation. (orig.)

  2. What is the clinical significance of chest CT when the chest x-ray result is normal in patients with blunt trauma?

    Science.gov (United States)

    Kea, Bory; Gamarallage, Ruwan; Vairamuthu, Hemamalini; Fortman, Jonathan; Lunney, Kevin; Hendey, Gregory W; Rodriguez, Robert M

    2013-08-01

    Computed tomography (CT) has been shown to detect more injuries than plain radiography in patients with blunt trauma, but it is unclear whether these injuries are clinically significant. This study aimed to determine the proportion of patients with normal chest x-ray (CXR) result and injury seen on CT and abnormal initial CXR result and no injury on CT and to characterize the clinical significance of injuries seen on CT as determined by a trauma expert panel. Patients with blunt trauma older than 14 years who received emergency department chest imaging as part of their evaluation at 2 urban level I trauma centers were enrolled. An expert trauma panel a priori classified thoracic injuries and subsequent interventions as major, minor, or no clinical significance. Of 3639 participants, 2848 (78.3%) had CXR alone and 791 (21.7%) had CXR and chest CT. Of 589 patients who had chest CT after a normal CXR result, 483 (82.0% [95% confidence interval [CI], 78.7-84.9%]) had normal CT results, and 106 (18.0% [95% CI, 15.1%-21.3%]) had CTs diagnosing injuries-primarily rib fractures, pulmonary contusion, and incidental pneumothorax. Twelve patients had injuries classified as clinically major (2.0% [95% CI, 1.2%-3.5%]), 78 were clinically minor (13.2% [95% CI, 10.7%-16.2%]), and 16 were clinically insignificant (2.7% (95% CI, 1.7%-4.4%]). Of 202 patients with CXRs suggesting injury, 177 (87.6% [95% CI, 82.4%-91.5%]) had chest CTs confirming injury and 25 (12.4% [95% CI, 8.5%-17.6%]) had no injury on CT. Chest CT after a normal CXR result in patients with blunt trauma detects injuries, but most do not lead to changes in patient management. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Clinical courses and CT findings in the patients with contrast media-associated seizures

    International Nuclear Information System (INIS)

    Onda, Kiyoshi; Takeda, Norio; Tanaka, Ryuichi

    1987-01-01

    From February 1976 through March 1985, 12,479 patients underwent cranial computed tomography (CT) examinations with 65 % Angiografin (100 ml/kg for adults and 2 ml/kg for children). Among them, five patients experienced contrast media-associated seizures. The present study analyzed (1) the time of occurrence of seizures, (2) CT appearances at the time of seizures, (3) epileptogenecity, and (4) clinical features of seizures. Two patients had malignant gliomas, 2 metastatic brain tumors, and one hemangioendothelioma. Seizures occurred at CT examinations performed after the initial treatment, such as radiation or surgery, with the incidence for each patient varing from 2 to 5. There were lesions near the motor cortex on CT scans, and enhancement was observed in most cases. Three patients had experienced epilepsy attacks due to their underlying diseases. In the other two, contrast media-associated seizures preceded the occasional onset of epilepsy attacks. This strongly suggested the influence of their underlying diseases in the occurrence of contrast media-associated seizures. A careful use of contrast media for cranial CT examination is emphasized. (Namekawa, K.)

  4. Clinical and CT characteristics of surgically resected lung adenocarcinomas harboring ALK rearrangements or EGFR mutations

    International Nuclear Information System (INIS)

    Wang, Hua; Schabath, Matthew B.; Liu, Ying; Han, Ying; Li, Qi; Gillies, Robert J.; Ye, Zhaoxiang

    2016-01-01

    Purpose: To determine if clinical and CT characteristics of surgically resected lung adenocarcinomas can distinguish those harboring ALK rearrangements from EGFR mutations. Materials and methods: Patients who had surgical resection and histologically confirmed lung adenocarcinoma were enrolled, including 41 patients with ALK rearrangements and 66 patients with EGFR mutations. Eighteen categorical and six quantitative CT characteristics were used to evaluate the tumors. Differences in clinical and CT characteristics between the two groups were investigated. Results: Age (P = 0.003), histological subtypes (P < 0.001), pathological stage (P = 0.007), and five CT characteristics, including size (P < 0.001), GGO (P = 0.001), bubble-like lucency (P = 0.048), lymphadenopathy (P = 0.001), and tumor shadow disappearance rate (P = 0.005) were significantly different between patients harboring ALK rearrangements compared to patients with EGFR mutations. When we compared histologic components, a solid pattern was more common (P = 0.009) in tumors with ALK rearrangements, and lepidic and acinar patterns were more common (P < 0.001 and P = 0.040, respectively) in those with EGFR mutations. Backward elimination analyses revealed that age (OR = 0.93; 95% CI 0.89–0.98), GGO (OR = 0.14; 95% CI 0.03–0.67), and lymphadenopathy (OR = 4.15; 95% CI 1.49–11.60) were significantly associated with ALK rearrangement status. Conclusion: Our analyses revealed that clinical and CT characteristics of lung adenocarcinomas harboring ALK rearrangements were significantly different, compared with those with EGFR mutations. These differences may be related to the molecular pathology of these diseases.

  5. Clinical and CT characteristics of surgically resected lung adenocarcinomas harboring ALK rearrangements or EGFR mutations

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hua [Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin (China); Schabath, Matthew B. [Department of Cancer Epidemiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Liu, Ying [Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin (China); Department of Cancer Imaging and Metabolism, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Han, Ying [Department of Biotherapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin (China); Li, Qi [Department of Pathology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin (China); Gillies, Robert J. [Department of Cancer Imaging and Metabolism, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Department of Radiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Ye, Zhaoxiang, E-mail: yezhaoxiang@163.com [Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin (China)

    2016-11-15

    Purpose: To determine if clinical and CT characteristics of surgically resected lung adenocarcinomas can distinguish those harboring ALK rearrangements from EGFR mutations. Materials and methods: Patients who had surgical resection and histologically confirmed lung adenocarcinoma were enrolled, including 41 patients with ALK rearrangements and 66 patients with EGFR mutations. Eighteen categorical and six quantitative CT characteristics were used to evaluate the tumors. Differences in clinical and CT characteristics between the two groups were investigated. Results: Age (P = 0.003), histological subtypes (P < 0.001), pathological stage (P = 0.007), and five CT characteristics, including size (P < 0.001), GGO (P = 0.001), bubble-like lucency (P = 0.048), lymphadenopathy (P = 0.001), and tumor shadow disappearance rate (P = 0.005) were significantly different between patients harboring ALK rearrangements compared to patients with EGFR mutations. When we compared histologic components, a solid pattern was more common (P = 0.009) in tumors with ALK rearrangements, and lepidic and acinar patterns were more common (P < 0.001 and P = 0.040, respectively) in those with EGFR mutations. Backward elimination analyses revealed that age (OR = 0.93; 95% CI 0.89–0.98), GGO (OR = 0.14; 95% CI 0.03–0.67), and lymphadenopathy (OR = 4.15; 95% CI 1.49–11.60) were significantly associated with ALK rearrangement status. Conclusion: Our analyses revealed that clinical and CT characteristics of lung adenocarcinomas harboring ALK rearrangements were significantly different, compared with those with EGFR mutations. These differences may be related to the molecular pathology of these diseases.

  6. SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

    International Nuclear Information System (INIS)

    Zhang, J; Ge, G; Winkler, M; Cong, W; Wang, G

    2014-01-01

    Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose

  7. WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

    International Nuclear Information System (INIS)

    Karellas, A.

    2016-01-01

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  8. WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Karellas, A. [University of Massachusetts Medical School (United States)

    2016-06-15

    investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography

  9. Clinical evaluation of respiration-induced attenuation uncertainties in pulmonary 3D PET/CT.

    Science.gov (United States)

    Kruis, Matthijs F; van de Kamer, Jeroen B; Vogel, Wouter V; Belderbos, José Sa; Sonke, Jan-Jakob; van Herk, Marcel

    2015-12-01

    In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data. Studies have demonstrated that these offsets can cause errors in quantitative PET measures. The purpose of this study is to quantify the effects of respiration-induced CT differences on the attenuation correction of pulmonary 18-fluordeoxyglucose (FDG) 3D PET/CT in a patient population and to investigate contributing factors. For 32 lung cancer patients, 3D-CT, 4D-PET and 4D-CT data were acquired. The 4D FDG PET data were attenuation corrected (AC) using a free-breathing 3D-CT (3D-AC), the end-inspiration CT (EI-AC), the end-expiration CT (EE-AC) or phase-by-phase (P-AC). After reconstruction and AC, the 4D-PET data were averaged. In the 4Davg data, we measured maximum tumour standardised uptake value (SUV)max in the tumour, SUVmean in a lung volume of interest (VOI) and average SUV (SUVmean) in a muscle VOI. On the 4D-CT, we measured the lung volume differences and CT number changes between inhale and exhale in the lung VOI. Compared to P-AC, we found -2.3% (range -9.7% to 1.2%) lower tumour SUVmax in EI-AC and 2.0% (range -0.9% to 9.5%) higher SUVmax in EE-AC. No differences in the muscle SUV were found. The use of 3D-AC led to respiration-induced SUVmax differences up to 20% compared to the use of P-AC. SUVmean differences in the lung VOI between EI-AC and EE-AC correlated to average CT differences in this region (ρ = 0.83). SUVmax differences in the tumour correlated to the volume changes of the lungs (ρ = -0.55) and the motion amplitude of the tumour (ρ = 0.53), both as measured on the 4D-CT. Respiration-induced CT variations in clinical data can in extreme cases lead to SUV effects larger than 10% on PET attenuation correction. These differences were case specific and correlated to differences in CT number

  10. Clinical significance of CT in the preoperative diagnosis of the staging of rectal cancer patients

    International Nuclear Information System (INIS)

    Itano, Satoshi; Fuchimoto, Sadanori; Hamada, Fumihiro; Kimura, Takanobu; Iwagaki, Hiromi; Maeda, Tetsuya; Orita, Kunzo

    1987-01-01

    The value of computed tomography (CT) in the preoperative clinical staging of rectal cancer was prospectively studied in 28 patients with macroscopically proven cancer. The CT studies were based on the previously established CT diagnostic criteria for wall invasion (S factor), lymph node metastases (N factor), and liver metastases (H factor). When macroscopic findings were used as the standard, the accuracy of CT was 61 % for S factor, 32 % for N factor, and 86 % for H factor. Using histological findings as the standard, the accuracy was 48 % for S factor and 16 % for N factor. Overall, CT had a high accuracy for H factor in all sites of cancer (75 % in the rectosigmoid, 86 % in the area above the peritoneal reflection, and 90 % in the area below the peritoneal reflection). For the other S and N factors, CT seemed to be of limited value in the preoperative diagnosis. (Namekawa, K.)

  11. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  12. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  13. Adherence to Radiology Recommendations in a Clinical CT Lung Screening Program.

    Science.gov (United States)

    Alshora, Sama; McKee, Brady J; Regis, Shawn M; Borondy Kitts, Andrea K; Bolus, Christopher C; McKee, Andrea B; French, Robert J; Flacke, Sebastian; Wald, Christoph

    2018-02-01

    Assess patient adherence to radiologist recommendations in a clinical CT lung cancer screening program. Patients undergoing CT lung cancer screening between January 12, 2012, and June 12, 2013, were included in this institutional review board-approved retrospective review. Patients referred from outside our institution were excluded. All patients met National Comprehensive Cancer Network Guidelines Lung Cancer Screening high-risk criteria. Full-time program navigators used a CT lung screening program management system to schedule patient appointments, generate patient result notification letters detailing the radiologist follow-up recommendation, and track patient and referring physician notification of missed appointments at 30, 60, and 90 days. To be considered adherent, patients could be no more than 90 days past due for their next recommended examination as of September 12, 2014. Patients who died, were diagnosed with cancer, or otherwise became ineligible for screening were considered adherent. Adherence rates were assessed across multiple variables. During the study interval, 1,162 high-risk patients were screened, and 261 of 1,162 (22.5%) outside referrals were excluded. Of the remaining 901 patients, 503 (55.8%) were male, 414 (45.9%) were active smokers, 377 (41.8%) were aged 65 to 73, and >95% were white. Of the 901 patients, 772 (85.7%) were adherent. Most common reasons for nonadherence were patient refusal of follow-up exam (66.7%), inability to successfully contact the patient (20.9%), and inability to obtain the follow-up order from the referring provider (7.8%); 23 of 901 (2.6%) were discharged for other reasons. High rates of adherence to radiologist recommendations are achievable for in-network patients enrolled in a clinical CT lung screening program. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Goblet cell carcinoid neoplasm of the appendix: Clinical and CT features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K.S., E-mail: kyungmouklee@alum.mit.edu [Department of Radiology Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Tang, L.H., E-mail: tangl@mskc.org [Department of Pathology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Shia, J., E-mail: shiaj@mskcc.org [Department of Pathology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Paty, P.B., E-mail: patyp@mskcc.org [Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Weiser, M.R., E-mail: weiser1@mskcc.org [Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Guillem, J.G., E-mail: guillemj@mskcc.org [Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Temple, L.K., E-mail: temple@mskcc.org [Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Nash, G.M., E-mail: nashg@mskcc.org [Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Reidy, D., E-mail: reidyd@mskcc.org [Department of Medicine, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Saltz, L., E-mail: saltzl@mskcc.org [Department of Medicine, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Gollub, M.J., E-mail: gollubm@mskcc.org [Department of Radiology Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States)

    2013-01-15

    Purpose: To describe the clinical and CT imaging features of goblet cell carcinoid (GCC) neoplasm of the appendix. Methods and materials: A computer search of pathology and radiology records over a 19-year period at our two institutions was performed using the search string “goblet”. In the patients with appendiceal GCC neoplasms who had abdominopelvic CT, imaging findings were categorized, blinded to gross and surgical description, as: “Appendicitis”, “Prominent appendix without peri-appendiceal infiltration”, “Mass” or “Normal appendix”. The CT appearance was correlated with an accepted pathological classification of: low grade GCC, signet ring cell adenocarcinoma ex, and poorly differentiated adenocarcinoma ex GCC group. Results: Twenty-seven patients (age range, 28–80 years; mean age, 52 years; 15 female, 12 male) with pathology-proven appendiceal GCC neoplasm had CT scans that were reviewed. Patients presented with acute appendicitis (n = 12), abdominal pain not typical for appendicitis (n = 14) and incidental finding (n = 1). CT imaging showed 9 Appendicitis, 9 Prominent appendices without peri-appendiceal infiltration, 7 Masses and 2 Normal appendices. Appendicitis (8/9) usually correlated with typical low grade GCC on pathology. In contrast, the majority of Masses and Prominent Appendices without peri-appendiceal infiltration were pathologically confirmed to be signet ring cell adenocarcinoma ex GCC. Poorly differentiated adenocarcinoma ex GCC was seen in only a small minority of patients. Hyperattenuation of the appendiceal neoplasm was seen in a majority of cases. Conclusions: GCC neoplasm of the appendix should be considered in the differential diagnosis in patients with primary appendiceal malignancy. Our cases demonstrated close correlation between our predefined CT pattern and the pathological classification.

  15. Goblet cell carcinoid neoplasm of the appendix: Clinical and CT features

    International Nuclear Information System (INIS)

    Lee, K.S.; Tang, L.H.; Shia, J.; Paty, P.B.; Weiser, M.R.; Guillem, J.G.; Temple, L.K.; Nash, G.M.; Reidy, D.; Saltz, L.; Gollub, M.J.

    2013-01-01

    Purpose: To describe the clinical and CT imaging features of goblet cell carcinoid (GCC) neoplasm of the appendix. Methods and materials: A computer search of pathology and radiology records over a 19-year period at our two institutions was performed using the search string “goblet”. In the patients with appendiceal GCC neoplasms who had abdominopelvic CT, imaging findings were categorized, blinded to gross and surgical description, as: “Appendicitis”, “Prominent appendix without peri-appendiceal infiltration”, “Mass” or “Normal appendix”. The CT appearance was correlated with an accepted pathological classification of: low grade GCC, signet ring cell adenocarcinoma ex, and poorly differentiated adenocarcinoma ex GCC group. Results: Twenty-seven patients (age range, 28–80 years; mean age, 52 years; 15 female, 12 male) with pathology-proven appendiceal GCC neoplasm had CT scans that were reviewed. Patients presented with acute appendicitis (n = 12), abdominal pain not typical for appendicitis (n = 14) and incidental finding (n = 1). CT imaging showed 9 Appendicitis, 9 Prominent appendices without peri-appendiceal infiltration, 7 Masses and 2 Normal appendices. Appendicitis (8/9) usually correlated with typical low grade GCC on pathology. In contrast, the majority of Masses and Prominent Appendices without peri-appendiceal infiltration were pathologically confirmed to be signet ring cell adenocarcinoma ex GCC. Poorly differentiated adenocarcinoma ex GCC was seen in only a small minority of patients. Hyperattenuation of the appendiceal neoplasm was seen in a majority of cases. Conclusions: GCC neoplasm of the appendix should be considered in the differential diagnosis in patients with primary appendiceal malignancy. Our cases demonstrated close correlation between our predefined CT pattern and the pathological classification

  16. Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ke; Tang, Jie [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong, E-mail: gchen7@wisc.edu [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, 600 Highland Avenue, Madison, Wisconsin 53792 (United States)

    2014-04-15

    Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a “redder” NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose){sup −β} with the component β ≈ 0.25, which violated the classical σ ∝ (dose){sup −0.5} power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial

  17. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results

    International Nuclear Information System (INIS)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R.; Rohlfing, T.; Hosten, N.

    2004-01-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  19. Recurrent renal cell carcinoma: clinical and prognostic value of FDG PET/CT

    International Nuclear Information System (INIS)

    Alongi, Pierpaolo; Picchio, Maria; Gianolli, Luigi; Zattoni, Fabio; Spallino, Marianna; Saladini, Giorgio; Evangelista, Laura

    2016-01-01

    The purpose of our study was 1) to evaluate the diagnostic performance of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT), 2) to assess the impact of FDG PET/CT on treatment decision-making, and 3) to estimate the prognostic value of FDG PET/CT in the restaging process among patients with renal cell carcinoma (RCC). From the FDG PET/CT databases of San Raffaele Hospital in Milan, Italy, and the Veneto Institute of Oncology in Padua, Italy, we selected 104 patients with a certain diagnosis of RCC after surgery, and for whom at least 24 months of post-surgical FDG PET/CT, clinical, and instrumental follow-up data was available. The sensitivity and specificity of FDG PET/CT were assessed by histology and/or other imaging as standard of reference. Progression-free survival (PFS) and overall survival (OS) were computed using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used to identify predictors of outcome. FDG PET/CT resulted in a positive diagnosis in 58 patients and a negative diagnosis in 46 patients. Sensitivity and specificity were 74 % and 80 %, respectively. FDG PET/CT findings influenced therapeutic management in 45/104 cases (43 %). After a median follow-up period of 37 months (± standard deviation 12.9), 51 (49 %) patients had recurrence of disease, and 26 (25 %) had died. In analysis of OS, positive versus negative FDG PET/CT was associated with worse cumulative survival rates over a 5-year period (19 % vs. 69 %, respectively; p <0.05). Similarly, a positive FDG PET/CT correlated with a lower 3-year PFS rate. In addition, univariate and multivariate analysis revealed that a positive scan, alone or in combination with disease stage III-IV or nuclear grading 3-4, was associated with high risk of progression (multivariate analysis = hazard ratios [HRs] of 4.01, 3.7, and 2.8, respectively; all p < 0.05). FDG PET/CT is a valuable tool both in treatment decision-making and for

  20. Recurrent renal cell carcinoma: clinical and prognostic value of FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Alongi, Pierpaolo; Picchio, Maria; Gianolli, Luigi [IRCCS San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); Zattoni, Fabio [University of Padua, Department of Oncological and Surgical Sciences, Urology Clinic, Padua (Italy); Spallino, Marianna [University of Milano-Bicocca, Milan (Italy); Saladini, Giorgio; Evangelista, Laura [Veneto Institute of Oncology IOV - IRCCS, Padua, Italy, Radiotherapy and Nuclear Medicine Unit, Padua (Italy)

    2016-03-15

    The purpose of our study was 1) to evaluate the diagnostic performance of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT), 2) to assess the impact of FDG PET/CT on treatment decision-making, and 3) to estimate the prognostic value of FDG PET/CT in the restaging process among patients with renal cell carcinoma (RCC). From the FDG PET/CT databases of San Raffaele Hospital in Milan, Italy, and the Veneto Institute of Oncology in Padua, Italy, we selected 104 patients with a certain diagnosis of RCC after surgery, and for whom at least 24 months of post-surgical FDG PET/CT, clinical, and instrumental follow-up data was available. The sensitivity and specificity of FDG PET/CT were assessed by histology and/or other imaging as standard of reference. Progression-free survival (PFS) and overall survival (OS) were computed using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used to identify predictors of outcome. FDG PET/CT resulted in a positive diagnosis in 58 patients and a negative diagnosis in 46 patients. Sensitivity and specificity were 74 % and 80 %, respectively. FDG PET/CT findings influenced therapeutic management in 45/104 cases (43 %). After a median follow-up period of 37 months (± standard deviation 12.9), 51 (49 %) patients had recurrence of disease, and 26 (25 %) had died. In analysis of OS, positive versus negative FDG PET/CT was associated with worse cumulative survival rates over a 5-year period (19 % vs. 69 %, respectively; p <0.05). Similarly, a positive FDG PET/CT correlated with a lower 3-year PFS rate. In addition, univariate and multivariate analysis revealed that a positive scan, alone or in combination with disease stage III-IV or nuclear grading 3-4, was associated with high risk of progression (multivariate analysis = hazard ratios [HRs] of 4.01, 3.7, and 2.8, respectively; all p < 0.05). FDG PET/CT is a valuable tool both in treatment decision-making and for

  1. The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine. Pt. 2. Benefits versus risk of CT

    International Nuclear Information System (INIS)

    Westra, Sjirk J.

    2014-01-01

    In order to personalize the communication of the CT risk, we need to describe the risk in the context of the clinical benefit of CT, which will generally be much higher, provided a CT scan has a well-established clinical indication. However as pediatric radiologists we should be careful not to overstate the benefit of CT, being aware that medico-legal pressures and the realities of health care economics have led to overutilization of the technology. And even though we should not use previously accumulated radiation dose to a child as an argument against conducting a clinically indicated scan (the ''sunk-cost'' bias), we should consider patients' radiation history in the diagnostic decision process. As a contribution to future public health, it makes more sense to look for non-radiating alternatives to CT in the much larger group of basically healthy children who are receiving occasional scans for widely prevalent conditions such as appendicitis and trauma than to attempt lowering CT use in the smaller group of patients with chronic conditions with a limited life expectancy. When communicating the CT risk with individual patients and their parents, we should acknowledge and address their concerns within the framework of informed decision-making. When appropriate, we may express the individual radiation risk, based on estimates of summated absorbed organ dose, as an order of magnitude rather than as an absolute number, and compare this with the much larger natural cancer incidence over a child's lifetime, and with other risks in medicine and daily life. We should anticipate that many patients cannot make informed decisions on their own in this complex matter, and we should offer our guidance while maintaining respect for patient autonomy. Proper documentation of the informed decision process is important for future reference. In concert with our referring physicians, pediatric radiologists are well-equipped to tackle the complexities associated with the communication

  2. Clinical study of the image fusion between CT and FDG-PET in the head and neck region

    International Nuclear Information System (INIS)

    Shozushima, Masanori; Moriguchi, Hitoshi; Shoji, Satoru; Sakamaki, Kimio; Ishikawa, Yoshihito; Kudo, Keigo; Satoh, Masanobu

    1999-01-01

    Image fusion using PET and CT from the head and neck region was performed with the use of external markers on 7 patients with squamous cell carcinoma. The purpose of this study was to examine a resultant error and the clinical usefulness of image fusion. Patients had primary lesions of the tongue, the maxillary gingiva or the maxillary sinus. All patients underwent PET with FDG and CT to detect tumor sites. Of these 7 patients, diagnostic images and the clinical observation found 6 cases of regional lymph node metastasis of the neck. To ensure the anatomical detail of the PET images, small radioactive markers were placed on the philtrum and below both earlobes. The PET image and CT image were then overlapped on a computer. The image fusion of PET and CT was successfully performed on all patients. The superposition error of this method was examined between the PET and CT images. The accuracy of fit measured as the mean distance between the PET and CT image was in the range of 2-5 mm. PET-CT superimposed images produced an increase in the localization of tumor FDG uptake and localized FDG uptake on the palatine tonsils. The marker system described here for the alignment of PET and CT images can be used on a routine basis without the invasive fixation of external markers, and also improve the management and follow up on patients with head and neck carcinoma. (author)

  3. Arterial phase CT for the detection of splenic injuries in blunt trauma: would it improve clinical outcomes?

    Science.gov (United States)

    Corwin, Michael T; Fananapazir, Ghaneh; Lamba, Ramit; Salcedo, Edgardo S; Holmes, James F

    2016-01-01

    To determine if the addition of an arterial phase abdominal computed tomography (CT) improves clinical outcomes in patients with blunt splenic injuries. Retrospective review of patients who underwent CT of the abdomen revealing splenic injuries. Clinical management in these patients was determined. Fifty-one of three thousand five hundred twenty-five patients had splenic injuries. Twenty-five patients underwent nonsurgical management, and 3 failed. The theoretical additional arterial phase resulted in a 62% increase in mean effective dose compared to the portal venous phase alone. Routine use of arterial phase CT in blunt trauma patients may not be warranted as there is minimal improvement in outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Diagnostic accuracy of the clinical and CT findings for differentiating Kikuchi's disease and tuberculous lymphadenitis presenting with cervical lymphadenopathy.

    Science.gov (United States)

    Baek, Hye Jin; Lee, Jeong Hyun; Lim, Hyun Kyung; Lee, Ha Young; Baek, Jung Hwan

    2014-11-01

    To determine the optimal clinical and CT findings for differentiating Kikuchi's disease (KD) and tuberculous lymphadenitis (TB) in patients presenting with cervical lymphadenopathy. From 2006 to 2010, 87 consecutive patients who were finally diagnosed with KD or TB were enrolled. Two radiologists performed independent analysis of contrast-enhanced neck CT images with regard to the involvement pattern, nodal or perinodal changes, and evidence of the previous infection. Significant clinical and CT findings of KD were determined by statistical analyses. Of the 87 patients, 27 (31%) were classified as having KD and 60 (69%) as having TB. Statistically significant findings of KD patients were younger age, presence of fever, involvement of ≥5 nodal levels or the bilateral neck, no or minimal nodal necrosis, marked perinodal infiltration, and no evidence of upper lung lesion or mediastinal lymphadenopathy. The presence of four or more statistically significant clinical and CT findings of KD had the largest area under the receiver-operating characteristic curve (A z = 0.861; 95% confidence intervals 0.801, 0.909), with a sensitivity of 89% and specificity of 83%. CT can be a helpful tool for differentiating KD from TB, especially when it is combined with the clinical findings.

  5. Effects of ray profile modeling on resolution recovery in clinical CT

    International Nuclear Information System (INIS)

    Hofmann, Christian; Knaup, Michael; Kachelrieß, Marc

    2014-01-01

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to

  6. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  7. The role of the computed tomography in head and neck cancer: Comparison of CT staging with clinical staging in oral cavity, oropharynx and larynx cancer

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Lee, Yul; Han, Man Chung

    1985-01-01

    Thirty-six patients (24 with oral cavity or oropharynx cancers and 12 larynx cancers) were prospectively examined with computed tomography (CT) to determine its value in staging the primary tumor and to compare with the clinical staging. The CT staging agreed with the clinical staging in 50% (12/24) of the oral cavity or oropharynx cancers and in 67% (8/12) of the larynx cancers. The CT upgraded the clinical staging in 29% (7/24) of the oral cavity or oropharynx tumors and in 33% (4/12) of the larynx cancers, whereas the CT downgrade the clinical staging in 21% (5/24) of the oral cavity or oropharynx cancers. There is no downgrade on CT in larynx cancer. The post-surgical confirmation was not made in most of the cases. The possible causes of disagreement between the CT and the clinical staging, and the diagnostic value of the CT in evaluation of the primary tumor in oral cavity, oropharynx and larynx were discussed

  8. Spontaneous vertebral dissection: Clinical, conventional angiographic, CT, and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Provenzale, J.M.; Morgenlander, J.C. [Duke Univ. Medical Center, Durham, NC (United States); Gress, D. [Univ. of California, San Francisco, CA (United States)

    1996-03-01

    The purpose of this study was to determine if typical clinical and neuroradiologic patterns exist in patients with spontaneous vertebral artery (VA) dissection. The medical records and neuroradiologic examinations of 14 patients with spontaneous VA dissection were reviewed. The medical records were examined to exclude patients with a history of trauma and to record evidence of a nontratimatic precipitating event ({open_quotes}trivial trauma{close_quotes}) and presence of possible risk factors such as hypertension. All patients under-went conventional angiography, 13 either CT or MRI (II both CT and MRI), and 3 MRA. Conventional arteriograrris were evaluated for dissection site, evidence of fibromuscular dysplasia, luminal stenosis or occlusion, and pseudoaneurysm formation, CT examinations for the presence of infarction or subarachnoid hemorrhage, MR examinations for the presence of infarction or arterial signal abnormality, and MR angiograms for abnormality of the arterial signal column. Seven patients had precipitating events within 24 h of onset of symptoms that may have been causative of dissection and five had hypertension. At catheter angiography, two patients had dissections in two arteries (both VAs in one patient, VA and internal carotid artery in one patient), giving a total of 15 VAs with dissection. Dissection sites included V1 in four patients, V2 in one patient, V3 in three patients, V4 in six patients, and both V3 and V4 in one patient. Luminal stenosis was present in 13 VAs, occlusion in 2, pseudoaneurysm in 1, and evidence of fibromuscular dysplasia in 1. Posterior circulation infarcts were found on CT or MR in five patients. Subarachnoid hemorrhage was found on CT in two patients and by lumbar puncture alone in two patients. Abnormal periarterial signal on MRI was seen in three patients. MRA demonstrated absent VA signal in one patient, pseudoaneurysm in one, and a false-negative examination in one.

  9. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT

    International Nuclear Information System (INIS)

    Kloeppel, R.; Kahn, T.; Schreiter, D.; Dietrich, J.; Josten, C.

    2002-01-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of ∼30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by ∼4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [de

  10. Blunt hepatic and splenic trauma in children: correlation of a CT injury severity scale with clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Ruess, L. [Dept. of Diagnostic Imaging and Radiology, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences, Washington, DC (United States); Sivit, C.J. [Dept. of Diagnostic Imaging and Radiology, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences, Washington, DC (United States)]|[Dept. of Pediatrics, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences, Washington, DC (United States); Eichelberger, M.R. [Dept. of Pediatrics, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences, Washington, DC (United States)]|[Dept. of Surgery, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences Washington, DC (United States); Taylor, G.A. [Dept. of Diagnostic Imaging and Radiology, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences, Washington, DC (United States); Bond, S.J. [Dept. of Surgery, Children`s National Medical Center, and George Washington Univ. School of Medicine and Health Sciences Washington, DC (United States)

    1995-07-01

    The purpose of this report is to compare a computed tomography (CT) injury severity scale for hepatic and splenic injury with the following outcome measures: requirement for surgical hemostasis, requirement for blood transfusion and late complications. Sixty-nine children with isolated hepatic injury and 53 with isolated splenic injury were prospectively classified at CT according to extent of parenchymal involvement. Clinical records were reviewed to determine clinical outcome. Ninety-seven children (80%) were managed non-operatively without transfusion. One child with hepatic injury required surgical hemostasis, and 17 (25%) required transfusion of blood. Increasing severity of hepatic injury at CT was associated with progressively greater frequency of transfusion (P = 0.002 by {chi}{sup 2}-test). One child with splenic injury underwent surgery and eight (15%) required transfusion of blood. Splenic injury grade at CT did not correlate with frequency (P = 0.41 by {chi}{sup 2}-test) or amount (P = 0.35 by factorial analysis of variance) of transfusion. There was one late complication in the nonsurgical group. A majority of children with hepatic and splenic injury were managed non-operatively without requiring blood transfusion. The severity of injury by CT scan did not correlate with need for surgery. Increasing grade of hepatic injury at CT was associated with increasing frequency of blood transfusion. CT staging was not discriminatory in predicting transfusion requirement in splenic injury. (orig.)

  11. Blunt hepatic and splenic trauma in children: correlation of a CT injury severity scale with clinical outcome

    International Nuclear Information System (INIS)

    Ruess, L.; Sivit, C.J.; Eichelberger, M.R.; Taylor, G.A.; Bond, S.J.

    1995-01-01

    The purpose of this report is to compare a computed tomography (CT) injury severity scale for hepatic and splenic injury with the following outcome measures: requirement for surgical hemostasis, requirement for blood transfusion and late complications. Sixty-nine children with isolated hepatic injury and 53 with isolated splenic injury were prospectively classified at CT according to extent of parenchymal involvement. Clinical records were reviewed to determine clinical outcome. Ninety-seven children (80%) were managed non-operatively without transfusion. One child with hepatic injury required surgical hemostasis, and 17 (25%) required transfusion of blood. Increasing severity of hepatic injury at CT was associated with progressively greater frequency of transfusion (P = 0.002 by χ 2 -test). One child with splenic injury underwent surgery and eight (15%) required transfusion of blood. Splenic injury grade at CT did not correlate with frequency (P = 0.41 by χ 2 -test) or amount (P = 0.35 by factorial analysis of variance) of transfusion. There was one late complication in the nonsurgical group. A majority of children with hepatic and splenic injury were managed non-operatively without requiring blood transfusion. The severity of injury by CT scan did not correlate with need for surgery. Increasing grade of hepatic injury at CT was associated with increasing frequency of blood transfusion. CT staging was not discriminatory in predicting transfusion requirement in splenic injury. (orig.)

  12. Clinical role of 18F-fluorodeoxyglucose PET-CT in the management of head and neck cancers

    International Nuclear Information System (INIS)

    Zhang Yu'na; Zhao Jinhua

    2007-01-01

    The combined PET and CT scan provides more accurate detection of tumors by providing the functional and anatomic information simultaneously, 18 F-fluorodeoxyglucose PET-CT has clinical value in localizing primary tumor, staging before treatment, monitoring the residual and recurrent diseases after radiotherapy and providing biological target volume to radiation treatment planning. (authors)

  13. First experiences with multidetector CT in traumatized children

    International Nuclear Information System (INIS)

    Hoermann, Marcus; Scharitzer, Martina; Philipp, M.; Metz, Viktor M.; Lomoschitz, F.

    2003-01-01

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment

  14. First experiences with multidetector CT in traumatized children

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, Marcus E-mail: marcus.hoermann@univie.ac.at; Scharitzer, Martina; Philipp, M.; Metz, Viktor M.; Lomoschitz, F

    2003-10-01

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment.

  15. 18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Imperiale, Alessio, E-mail: alessio.imperiale@chru-strasbourg.fr; Namer, Izzie Jacques, E-mail: izzie.jacques.namer@chru-strasbourg.fr [Hôpital de Hautepierre (Hôpitaux Universitaires de Strasbourg, HUS), Department of Biophysics and Nuclear Medicine (France); Bachellier, Philippe, E-mail: philippe.bachellier@chru-strasbourg.fr [Hôpital de Hautepierre (Hôpitaux Universitaires de Strasbourg, HUS), Hepato-Pancreato-Biliary Surgery and Liver Transplantation (France); Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2016-09-15

    AimTo review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs).Materials and MethodsThree patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; <3 cm) on 18F-FDOPA PET/CT; poor lesion visualisation on US, CT, and MR; and ongoing symptoms. Procedures were performed in an interventional PET/CT scanner under general anaesthesia using a split-dose protocol. Lesion characteristics, procedural duration and technical success (accurate probe placement and post-procedural ablation-zone photopaenia), complications, patient and operator dose, and clinical outcomes were evaluated.ResultsThirteen liver metastases (mean size 11.4 mm, range 8–16) were treated in three patients (two presented with “carcinoid syndrome”). Technical success was 100 % with a mean procedural duration of 173.3 min (range 90–210) and no immediate complications. Mean patient dose was 2844 mGy·cm (range 2104–3686). Operator and radiographer doses were acceptable other than the operator’s right hand in the first case (149 µSv); this normalised in the second case. There was no local tumour or extra-hepatic disease progression at mid-term follow-up (mean 12.6 months; range 6–20); however, two cases progressed with new liver metastases at different sites. There was 100 % clinical success (n = 2) in resolving carcinoid syndrome symptoms.Conclusion18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.

  16. Clinical study of acute cerebral infarction with a midline shift on the CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takemae, T; Mizukami, M; Kin, H; Kawase, T; Araki, G [Mihara Memorial Hospital, Isezaki, Gunma (Japan)

    1978-12-01

    Twenty-one cases of acute cerebral infarction with a midline shift on the CT scan were studied with respect to the development of the midline shift, the angiographic findings, the clinical pictures and the outcome of these patients. The CT findings of hemorrhagic infarction were also studied. No cases showed a midline shift on a CT scan taken within 6 hours after the onset. A midline shift was, however, noted as early as 9 hours after the onset, and it reached its peak between the 2nd and 7th day of the onset. It gradually disappeared by the end of the third week. Hemorrhagic infarction was diagnosed in 6 patients by either spinal tap or autopsy. The CT findings of these hemorrhagic infarction were divided into two types, solid hemorrhages with an unequivocal high density within the low-density area, and small, scattered hemorrhagic of almost the same density as normal brain tissue within the low-density area. In 19 of 21 patients, an round-edged occlusion and/or embolus were observed on the initial angiograms. The recanalization of the occluded vessels was proved in 10 of 14 patients by subsequent angiographic studies. Twenty of 21 patients showed a sudden development of neurological symptoms, and 15 patients had a history of various kinds of heart disease, such as atrial fibrillation, valvular heart disease and myocardial infarction. The patients had atrial fibrillation on EKG on admission. These angiographic findings and clinical pictures strongly suggest that the infarction with a midline shift on the CT scan may be caused by a cerebral embolism of cardiac origin. Eight patients died of cerebral herniation between the 2nd and 6th day of the onset. Taking these poor outcomes into consideration, surgical as well as medical decompression of the brain would seem to be most important when the CT scan shows a midline shift.

  17. Clinical impact of PET/CT imaging after adjuvant therapy in patients with oral cavity squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Huan-Chun [Chang Gung Memorial Hospital and Chang Gung University, Department of Nuclear Medicine and Molecular Imaging Center, Taoyuan (China); Kang, Chung-Jan; Huang, Shiang-Fu; Liao, Chun-Ta [Chang Gung Memorial Hospital and Chang Gung University, Department of Otorhinolaryngology, Head and Neck Surgery, Taoyuan (China); Wang, Hung-Ming [Chang Gung Memorial Hospital and Chang Gung University, Department of Medical Oncology, Taoyuan (China); Lin, Chien-Yu [Chang Gung Memorial Hospital and Chang Gung University, Department of Radiation Oncology, Taoyuan (China); Lee, Li-Yu [Chang Gung Memorial Hospital and Chang Gung University, Department of Pathology, Taoyuan (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital and Chang Gung University, Department of Nuclear Medicine and Molecular Imaging Center, Taoyuan (China); Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine, Taoyuan (China)

    2017-09-15

    This single-center retrospective study of prospectively collected data was aimed at comparing the clinical outcomes of positron emission tomography/computed tomography (PET/CT) for patients with oral cavity squamous cell carcinoma (OSCC) with symptomatic recurrences identified by PET/CT imaging following adjuvant therapy (Group A) versus those of cases with asymptomatic recurrences diagnosed through periodic post-adjuvant therapy PET/CT surveillance (Group B). We also sought to establish the priority of salvage therapy in the two study groups. We identified 111 patients with advanced resected OSCC who developed recurrences following adjuvant therapy (51 in Group A and 60 in Group B). Histopathology served as the gold standard for recurrent lesions. The impact of post-adjuvant therapy PET/CT surveillance was examined with Kaplan-Meier curves and Cox proportional hazards regression models. The 2-year DSS and OS rates were marginally or significantly higher in Group B than in Group A (P = 0.073 and P = 0.025, respectively). Time-dependent ROC curve analysis demonstrated that the optimal cutoff values for time to positive PET/CT findings in relation to OS were 12 months for Group A and 9 months for Group B, respectively. Independent risk factors identified in multivariate analyses were used to devise two prognostic scoring systems for 2-year DSS and OS in each study group (all P < 0.001). Scheduled periodic PET/CT surveillance is a valuable tool for early detection of recurrent lesion(s) in asymptomatic OSCC patients who bear risk factors for disease recurrence. The presence of clinical symptoms and a short time to positive PET/CT findings were adverse prognostic factors for clinical outcome in patients with advanced OSCC. The priority of salvage therapy is discussed in each patient subgroup according to the devised prognostic scoring systems. (orig.)

  18. CT classification and clinical prognosis of cerebral infarction in the area of middle cerebral artery

    International Nuclear Information System (INIS)

    Konno, Jyoji

    1983-01-01

    Computerized tomographies (CT) were repeatedly scanned on 70 patients with cerebral infarction in the middle cerebral artery. Low density area (LDA) was measured with HounFsfield's Unit (HU) and studied on the progressive changes. Classification of LDA was attempted and studied on correlation with mass effect, contrast enhancement, angiographical findings, clinical symptoms and prognosis. It was considered that important points of diagnosis of cerebral infarction were timing of examination of CT and determination of LDA with HUF. It was also thought that CT classification of LDA was usefull to estimate prognosis of the patients with cerebral infarction. (author)

  19. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  20. Head-to-head comparison between {sup 18}F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela [University Hospitals of Strasbourg, Department of Radiology, Strasbourg (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Goichot, Bernard; Chabrier, Gerard [University Hospitals of Strasbourg, Department of Internal Medicine, Strasbourg (France); Petit-Thomas, Julie; Charpiot, Anne [University Hospitals of Strasbourg, Department of Otolaryngology and Maxillofacial Surgery, Strasbourg (France); Averous, Gerlinde [University Hospitals of Strasbourg, Department of Pathology, Strasbourg (France); Imperiale, Alessio [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Hautepierre University Hospital, Biophysics and Nuclear Medicine, Strasbourg Cedex (France)

    2017-06-15

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of {sup 18}F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both {sup 18}F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further {sup 18}F-FDOPA PET/CT and/or MRA. {sup 18}F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. {sup 18}F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. {sup 18}F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, {sup 18}F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. {sup 18}F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that {sup 18}F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when {sup 68

  1. Head-to-head comparison between "1"8F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    International Nuclear Information System (INIS)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques; Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela; Taieb, David; Goichot, Bernard; Chabrier, Gerard; Petit-Thomas, Julie; Charpiot, Anne; Averous, Gerlinde; Imperiale, Alessio

    2017-01-01

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of "1"8F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both "1"8F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further "1"8F-FDOPA PET/CT and/or MRA. "1"8F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. "1"8F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. "1"8F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, "1"8F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. "1"8F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that "1"8F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when "6"8Ga-labeled somatostatin analogues are

  2. Repeated CT studies of a patient with herpes simplex encephalitis during his entire clinical course

    International Nuclear Information System (INIS)

    Shiraishi, Masahiro; Fukui, Keiji; Takeda, Sadanori; Sadamoto, Kazuhiko; Kimura, Hideki; Sakaki, Saburo.

    1985-01-01

    We encountered a patient with herpes simplex encephalitis whose cerebral lesions were studied by repeated CT scannings during his entire clinical course. The purpose of this paper is to report the earliest lesions of the brain as revealed by CT scans. A 63-year-old man was admitted to our clinic complaining of headache, nausea, fever, and disorientation. On admission, a physical examination showed a high fever, while a neurological examination revealed a stiff neck, a positive Kernig's sign, and disorientation. Laboratory examinations revealed a pleocytosis of the cerebrospinal fluid. Electroencephalograms showed the so-called ''periodic sharp-and-slow-waves complex''. The complement fixation titer for herpes simplex virus was x32 in the serum and x128 in the cerebrospinal fluid, suggesting the diagnosis of herpes simplex encephalitis. We treated him with adenine arabinoside and gamma-globulin, but the patient did not recover; rather, he died of pneumonia and gastrointestinal bleeding three months later. Plain CT scans taken on the 12th day after the onset revealed a low-density area with signs of a slight mass in the region from the right island of Reil to the right uncus. Contrast-enhanced CT scans revealed an irregular enhancement in the low-density area. CT scans taken on the 19th day after the onset showed an extensive low-density area with a streak-like enhancement in the right temporal lobe, which is in aggreement with the findings reported by others as characteristic CT findings for herpes simplex encephalitis. In order to make an early diagnosis of a patient, we should pay attention to a low-density area with an irregular contrast enhancement in the region from the island of Reil to the uncus on a CT scan. (author)

  3. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    Science.gov (United States)

    Nishii, Ryuichi; Nagamachi, Shigeki; Mizutani, Youichi; Terada, Tamasa; Kiyohara, Syogo; Wakamatsu, Hideyuki; Fujita, Seigo; Higashi, Tatsuya; Yoshinaga, Keiichiro; Saga, Tsuneo; Hirai, Toshinori

    2018-01-01

    We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i) thyroid hormone withdrawal (THW) group; (ii) recombinant human thyrotropin (rhTSH) group; (iii) hypothyroidism group; (iv) hyperthyroidism group; and (v) BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images.

  4. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  5. Chronic subdural hematoma with sedimentation level on CT: correlation with clinical and operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Hee; Lee, Hyeon Kyeong; Lee, Won Jae [College of Medicine, Dongguk University, Kyungju (Korea, Republic of)] (and others)

    1994-03-15

    The purpose of this study is to correlate CT findings of the patients with chronic subdural hematoma(SDH) showing a sedimentation level with their clinical and operative findings. We selected 9 patients who showed a sedimentation level within the hematoma after reviewing the CT findings of 55 patients with SDH. We also analyzed their age, initial symptoms, cause of head injury, latent period, the level of consciousness on admission, CT findings, and operative findings. All of the 9 patients were aged persons(over 52 years). They had a history of acute exacerbation of neurologic symptoms. Five of them had an apparent history of head trauma more than one month before the exacerbation. The CT scans showed unilateral, crescent-shaped subdural fluid collection with a sedimentation level except a case of bilateral SDH and 2 cases of planoconvex-shaped SDH. The interface of the sedimentation level was sharp in 3 cases and indistinct in 6 cases. None had bleeding tendency and the hemoglobin level was slightly decreased in 2 patients. All patients revealed membrane of the hematoma during operation. The upper portion of the sedimentation was liquefied blood and the lower portion was fresh blood clots. We could observe fresh RBC's in the hematoma microscopically. A sedimentation level in chronic SDH was operatively proved to represent rebleeding, and was clinically manifested as an acute exacerbation of symptoms.

  6. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  7. Learning in clinical practice: findings from CT, MRI and PACS

    OpenAIRE

    Sinozic, Tanja

    2014-01-01

    This thesis explores learning in clinical practice in the cases of CT, MRI and PACS in\\ud UK hospitals. It asks the questions of how and why certain evolutionary features of\\ud technology condition learning and change in medical contexts.\\ud Using an evolutionary perspective of cognitive and social aspects of technological\\ud change, this thesis explores the relationships between technology and organisational\\ud learning processes of intuition, interpretation, integration and institutionalisa...

  8. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  9. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  10. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  11. Low-dose CT image reconstruction using gain intervention-based dictionary learning

    Science.gov (United States)

    Pathak, Yadunath; Arya, K. V.; Tiwari, Shailendra

    2018-05-01

    Computed tomography (CT) approach is extensively utilized in clinical diagnoses. However, X-ray residue in human body may introduce somatic damage such as cancer. Owing to radiation risk, research has focused on the radiation exposure distributed to patients through CT investigations. Therefore, low-dose CT has become a significant research area. Many researchers have proposed different low-dose CT reconstruction techniques. But, these techniques suffer from various issues such as over smoothing, artifacts, noise, etc. Therefore, in this paper, we have proposed a novel integrated low-dose CT reconstruction technique. The proposed technique utilizes global dictionary-based statistical iterative reconstruction (GDSIR) and adaptive dictionary-based statistical iterative reconstruction (ADSIR)-based reconstruction techniques. In case the dictionary (D) is predetermined, then GDSIR can be used and if D is adaptively defined then ADSIR is appropriate choice. The gain intervention-based filter is also used as a post-processing technique for removing the artifacts from low-dose CT reconstructed images. Experiments have been done by considering the proposed and other low-dose CT reconstruction techniques on well-known benchmark CT images. Extensive experiments have shown that the proposed technique outperforms the available approaches.

  12. Modern imaging for pancreatitis, CT findings versus clinic

    International Nuclear Information System (INIS)

    Karlsboeck, S.

    2010-01-01

    The pancreas with all its diseases is radiologically examined with different methods. The most important ones are CT, MRI, ERCP and ultrasound. I would like to mention here that the diagnosis by ultrasound depends a lot on the person carrying out the examination but due to the availability it is preferably used as the first examination technique. Due to this fact the examination by ultrasound is only referred to quickly in this thesis. More emphasis is put on the different methods of examining certain diseases of the pancreas by CT and MRI. Due to the development of MRI devices which enable a better contrast of the soft tissue than the CT the CT has been pushed back. But also the CT has been developed rapidly that is why it is usually used as the method of choice. Most pancreas diseases can be distinguished well by CT and MRI. (author) [de

  13. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    Energy Technology Data Exchange (ETDEWEB)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Radiology - Sapienza, Rome (Italy); Anile, Marco; Venuta, Federico [University of Rome, Department of Thoracic Surgery - Sapienza, Rome (Italy); Vitolo, Domenico [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Pathology - Sapienza, Rome (Italy); Saba, Luca [Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, Monserrato (Italy); Longo, Flavia [University of Rome, Department of Radiological, Oncological and Anatomopathological Sciences - Oncology - Sapienza, Rome (Italy)

    2015-05-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  14. Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique

    International Nuclear Information System (INIS)

    Anzidei, Michele; Argiro, Renato; Porfiri, Andrea; Boni, Fabrizio; Zaccagna, Fulvio; Napoli, Alessandro; Leonardi, Andrea; Bezzi, Mario; Catalano, Carlo; Anile, Marco; Venuta, Federico; Vitolo, Domenico; Saba, Luca; Longo, Flavia

    2015-01-01

    Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. (orig.)

  15. Clinical Utility of SPECT/CT Imaging Post-Radioiodine Therapy: Does It Enhance Patient Management in Thyroid Cancer?

    Science.gov (United States)

    Hassan, Fahim U; Mohan, Hosahalli K

    2015-12-01

    The aim of this study was to evaluate post-therapy iodine-131 single-photon emission computed tomography/computed tomography ((131)I-SPECT/CT) imaging in comparison to conventional planar (131)I whole-body imaging, and to assess its clinical impact on the management of patients. We retrospectively reviewed planar (131)I whole-body and (131)I-SPECT/CT imaging findings in 67 patients who underwent (131)I therapy for thyroid cancer. Two nuclear medicine physicians reviewed the scans independently. The foci of increased tracer uptake were identified in the neck, thorax and elsewhere. Within the neck, the foci of (131)I-increased uptake were graded qualitatively as probable or definite uptake in thyroid remnants and probable or definite uptake in the lymph nodes. Serum thyroglobulin level, histopathology and other imaging findings served as the reference standard. Of the 67 patients, 57 (85%) had radioiodine avid disease and 10 (15%) demonstrated non-radioiodine avid disease. Overall, post-therapy (131)I-SPECT/CT downstaged lymph node staging in 10 patients and upstaged it in 4 patients. This translated into a change of management for 9/57 (16%) patients with radioiodine avid disease. A change of management was observed in 5/10 patients with non-radioiodine avid disease confirmed in the post-(131)I-SPECT/CT study. Additionally, clinically significant findings such as incidental lung cancer, symptomatic pleural effusion and consolidation were also diagnosed in both groups of patients. In patients with thyroid cancer, (131)I-SPECT/CT is a valuable addition to standard post-therapy planar imaging. SPECT/CT also improved diagnostic confidence and provided crucial clinical information leading to change of management for a significant number of these patients.

  16. The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine. Pt. 2. Benefits versus risk of CT

    Energy Technology Data Exchange (ETDEWEB)

    Westra, Sjirk J. [Massachusetts General Hospital, Division of Pediatric Radiology, Boston, MA (United States)

    2014-10-15

    In order to personalize the communication of the CT risk, we need to describe the risk in the context of the clinical benefit of CT, which will generally be much higher, provided a CT scan has a well-established clinical indication. However as pediatric radiologists we should be careful not to overstate the benefit of CT, being aware that medico-legal pressures and the realities of health care economics have led to overutilization of the technology. And even though we should not use previously accumulated radiation dose to a child as an argument against conducting a clinically indicated scan (the ''sunk-cost'' bias), we should consider patients' radiation history in the diagnostic decision process. As a contribution to future public health, it makes more sense to look for non-radiating alternatives to CT in the much larger group of basically healthy children who are receiving occasional scans for widely prevalent conditions such as appendicitis and trauma than to attempt lowering CT use in the smaller group of patients with chronic conditions with a limited life expectancy. When communicating the CT risk with individual patients and their parents, we should acknowledge and address their concerns within the framework of informed decision-making. When appropriate, we may express the individual radiation risk, based on estimates of summated absorbed organ dose, as an order of magnitude rather than as an absolute number, and compare this with the much larger natural cancer incidence over a child's lifetime, and with other risks in medicine and daily life. We should anticipate that many patients cannot make informed decisions on their own in this complex matter, and we should offer our guidance while maintaining respect for patient autonomy. Proper documentation of the informed decision process is important for future reference. In concert with our referring physicians, pediatric radiologists are well-equipped to tackle the complexities

  17. Is {sup 68}Ga-DOTA-NOC PET/CT indicated in patients with clinical, biochemical or radiological suspicion of neuroendocrine tumour?

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Valentina [S. Orsola-Malpighi University Hospital, Nuclear Medicine, Bologna (Italy); Azienda Ospedaliero Universitaria di Bologna, Policlinico S. Orsola-Malpighi, Nuclear Medicine, Pad 30, Bologna (Italy); Campana, Davide; Tomassetti, Paola [S. Orsola-Malpighi University Hospital, Internal Medicine, Bologna (Italy); Nanni, Cristina; Cambioli, Silvia; Fanti, Stefano [S. Orsola-Malpighi University Hospital, Nuclear Medicine, Bologna (Italy); Rubello, Domenico [Ospedale S. Maria della Misericordia, Nuclear Medicine, Rovigo (Italy)

    2012-08-15

    In recent years, {sup 68}Ga-DOTA-peptides positron emission tomography (PET)/CT has been increasingly used to study patients with neuroendocrine tumours (NET). However, performing specialized examinations in the appropriate contest is mandatory for both medical and economic reasons. The aim of the study is to evaluate the potential usefulness of {sup 68}Ga-DOTA-NOC PET/CT in patients with suspected NET. Among the patients undergoing {sup 68}Ga-DOTA-NOC PET/CT at our centre, we reviewed those studied for suspected NET based on the presence of either clinical signs/symptoms or imaging or raised biochemical markers or a combination of these conditions. PET/CT results were compared with clinical and imaging follow-up of at least 1 year or pathology. Overall 131 suspected NET cases were included. The most common condition considered suspicious for NET was the increase of blood markers (66), followed by inconclusive findings at conventional imaging (CI, 41), clinical signs/symptoms (10), equivocal {sup 18}F-fluorodeoxyglucose (FDG) PET (7) or somatostatin receptor scintigraphy (SRS, 4), or a combination of the above (3). PET/CT results were true-positive in 17 cases, true-negative in 112 and false-negative in 2 (overall sensitivity 89.5 %, specificity 100 %). Interestingly, increased blood markers and clinical signs/symptoms were associated with the lowest frequency of true-positive findings (1/66 and 1/10, respectively), while CI findings were confirmed in one third of the cases (13/41). Overall, the incidence of NET in the studied population was 14.5 % (19/131). Our data confirm the good accuracy (98 %) of {sup 68}Ga-DOTA-NOC PET/CT in NET lesion detection. However, our results also suggest that {sup 68}Ga-DOTA-NOC PET/CT may not be routinely recommended in patients with a suspicion of NET based on the mere detection of increased blood markers or clinical symptoms. Positive CI alone or in association with clinical/biochemical findings is on the contrary associated with

  18. Oxygen-enhanced MRI vs. quantitatively assessed thin-section CT: Pulmonary functional loss assessment and clinical stage classification of asthmatics

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Matsumoto, Keiko; Onishi, Yumiko; Nogami, Munenobu; Takenaka, Daisuke; Matsumoto, Sumiaki; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to prospectively compare the efficacy of oxygen-enhanced MR imaging (O 2 -enhanced MRI) and CT for pulmonary functional loss assessment and clinical stage classification of asthmatics. Materials and methods: O 2 -enhanced MRI, CT and %FEV 1 measurement were used 34 consecutive asthmatics classified into four stages ('Mild Intermittent [n = 7]', 'Mild Persistent [n = 8], 'Moderate Persistent [n = 14]' and 'Severe Persistent [n = 5]'). Relative enhancement ratio maps for every subject were generated, and determine mean relative enhancement ratios (MRERs). Mean lung density (MLD) and the airway wall area (WA) corrected by body surface area (WA/BSA) were also measured on CT. To compare the efficacy of the two methods for pulmonary functional loss assessment, all indexes were correlated with %FEV 1 . To determine the efficacy of the two methods for clinical stage classification, all parameters for the four clinical stages were statistically compared. Results: %FEV 1 showed fair or moderate correlation with all parameters (0.15 ≤ r 2 ≤ 0.30, p 2 -enhanced MRI is as effective as CT for pulmonary functional loss assessment and clinical stage classification of asthmatics.

  19. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures

    OpenAIRE

    Chapman, Brandon C.; Overbey, Douglas M.; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T.; French, Andrew; Johnson, Jeffrey L.; Burlew, Clay C.; Barnett, Carlton; Moore, Ernest E.; Pieracci, Fredric M.

    2016-01-01

    Background Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. Objectives The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Methods Retrospective coho...

  20. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    International Nuclear Information System (INIS)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice; Sebbane, Mustapha; Molinari, Nicolas; Riou, Bruno

    2017-01-01

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10 -6 ) and management (88.5% to 95.8%, p=2.6 x 10 -6 ) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  1. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice [CHU Lapeyronie, Department of Medical Imaging, Montpellier Cedex 5 (France); Sebbane, Mustapha [Department of Emergency Medicine, CHU Lapeyronie, Montpellier (France); Molinari, Nicolas [Department of Medical Information and Statistics, CHU Montpellier (France); Riou, Bruno [GH Pitie-Salpetriere, APHP, Department of Emergency Medicine and Surgery, Paris (France)

    2017-02-15

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10{sup -6}) and management (88.5% to 95.8%, p=2.6 x 10{sup -6}) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  2. Correlative study of the brain CT and clinical features of patients with Down's syndrome in three clinical stages of Alzheimer type dementia

    International Nuclear Information System (INIS)

    Maruyama, Keiko; Ikeda, Shu-ichi; Yanagisawa, Nobuo.

    1995-01-01

    Patients with Down's syndrome often develop Alzheimer type neuropathological changes as well as dementia of the Alzheimer type after the age of 40. We studied brain CT findings in relation to three clinical stages of Alzheimer type dementia in 11 patients with Down's syndrome aged from 17 to 55 years. In addition, 123 I-IMP-SPECT was studied in 4 of these patients. Dementia of the Alzheimer type was present in 9 patients; 5 patients were in the early stage, 2 were in the progressive stage, and the other 2 were in the end stage. The earliest CT finding was enlargement of the suprasellar cistern, which indicated atrophy of the medial temporal lobe including the hippocampus and amygdala. This finding was not present in non-demented individuals with Down's syndrome. Moreover, CT scans showed that brain atrophy progressed to the temporal, frontal lobe, and then generalized cerebral cortices, which correlated clinically with the severity of dementia. Studies of 123 I-IMP-SPECT in two patients with mild dementia revealed abnormally decreased isotope uptake in the temporal and posterior parietal regions. We suggest to measure the size of the suprasellar cistern in CT and SPECT scans for early detection and diagnosis of mild dementia of the Alzheimer type in patients with Down's syndrome. (author)

  3. Towards truly integrated hardware fusion with PET/CT

    International Nuclear Information System (INIS)

    Beyer, T.

    2005-01-01

    Combined PET/CT imaging is a non-invasive means of acquiring and reviewing both, the anatomy and the molecular pathways of a patient during a quasi-simultaneous examination. Since the introduction of the prototype PET/CT in 1998 this imaging technology has evolved rapidly. State-of-the-art PET/CT tomographs combine the latest technology in spiral, multi-slice CT and PET using novel scintillator materials and image reconstruction techniques. Together with novel patient positioning systems PET/CT tomographs allow to acquire complementary PET and CT data in a single exam with the best intrinsic co-registration. In addition to the hardware integration efforts have been made to integrate the acquisition and viewing software in PET/CT, thus making the diagnostic review and reporting more efficient. Based on the first clinical experiences and the technical evolution of combined imaging technology PET/CT has become a standard in diagnostic oncology. With high-performance imaging technology at hand today, standardized, high-quality PET/CT imaging protocols are needed to provide best oncology patient care. These protocols mandate the joint efforts of a multi-disciplinary team of physicians, physicists and radiochemists. (orig.)

  4. Classification of non-aneurysmal subarachnoid haemorrhage: CT correlation to the clinical outcome

    International Nuclear Information System (INIS)

    Nayak, S.; Kunz, A.B.; Kieslinger, K.; Ladurner, G.; Killer, M.

    2010-01-01

    Aim: To propose a new computed tomography (CT)-based classification system for non-aneurysmal subarachnoid haemorrhage (SAH), which predicts patients' discharge clinical outcome and helps to prioritize appropriate patient management. Methods and materials: A 5-year, retrospective, two-centre study was carried out involving 1486 patients presenting with SAH. One hundred and ninety patients with non-aneurysmal SAH were included in the study. Initial cranial CT findings at admission were correlated with the patients' discharge outcomes measured using the Modified Rankin Scale (MRS). A CT-based classification system (type 1-4) was devised based on the topography of the initial haemorrhage pattern. Results: Seventy-five percent of the patients had type 1 haemorrhage and all these patients had a good clinical outcome with a discharge MRS of ≤1. Eight percent of the patients presented with type 2 haemorrhage, 62% of which were discharged with MRS of ≤1 and 12% of patients had MRS 3 or 4. Type 3 haemorrhage was found in 10%, of which 16% had good clinical outcome, but 53% had moderate to severe disability (MRS 3 and 4) and 5% were discharged with severe disability (MRS 5). Six percent of patients presented with type 4 haemorrhage of which 42% of the patients had moderate to severe disability (MRS 3 and 4), 42% had severe disability and one-sixth of the patients died. Highly significant differences were found between type 1(1a and 1b) and type 2 (p = 0.003); type 2 and type 3 (p = 0.002); type 3 and type 4 (p = 0.001). Conclusion: Haemorrhages of the type 1 category are usually benign and do not warrant an extensive battery of clinical and radiological investigations. Type 2 haemorrhages have a varying prognosis and need to be investigated and managed along similar lines as that of an aneurysmal haemorrhage with emphasis towards radiological investigation. Type 3 and type 4 haemorrhages need to be extensively investigated to find an underlying cause.

  5. CT diagnosis of splenic infarction in blunt trauma: imaging features, clinical significance and complications

    International Nuclear Information System (INIS)

    Miller, L.A.; Mirvis, S.E.; Shanmuganathan, K.; Ohson, A.S.

    2004-01-01

    AIM: The object of this study is to describe the appearance, complications, and outcome of segmental splenic infarctions occurring after blunt trauma using computed tomography (CT). MATERIALS AND METHODS: Thirteen blunt trauma patients were identified with splenic infarction on contrast-enhanced CT. CT images were retrospectively reviewed and the percentage of infarcted splenic tissue and presence of splenic injury separate from the site of infarction were identified. Splenic angiograms were reviewed and follow-up CT images were assessed for interval change in the appearance of the infarcts. RESULTS: The mean age of patients was 32 years and the most common mechanism of injury was road traffic accident. The majority (54%) had 25-50% infarction of the spleen. Splenic angiograms were performed in nine patients and seven demonstrated wedge-shaped regions of decreased perfusion corresponding to the infarction seen on CT with no need for intervention. Eleven patients underwent a follow-up CT that demonstrated the following: no significant change in six, near-complete resolution in two, delayed appearance of infarction in one, abscess formation in one, and delayed splenic rupture in one. CONCLUSION: Segmental splenic infarction is a rare manifestation of blunt splenic trauma. The diagnosis is readily made using contrast-enhanced CT. The majority will decrease in size on follow-up CT and resolve without clinical sequelae. Resolution of infarction is also seen and these cases are best described as temporary perfusion defects. Splenic abscess or delayed rupture are uncommon complications that may necessitate angiographic or surgical intervention

  6. CT diagnosis of splenic infarction in blunt trauma: imaging features, clinical significance and complications

    Energy Technology Data Exchange (ETDEWEB)

    Miller, L.A.; Mirvis, S.E.; Shanmuganathan, K.; Ohson, A.S. E-mail: lmiller@um.edu

    2004-04-01

    AIM: The object of this study is to describe the appearance, complications, and outcome of segmental splenic infarctions occurring after blunt trauma using computed tomography (CT). MATERIALS AND METHODS: Thirteen blunt trauma patients were identified with splenic infarction on contrast-enhanced CT. CT images were retrospectively reviewed and the percentage of infarcted splenic tissue and presence of splenic injury separate from the site of infarction were identified. Splenic angiograms were reviewed and follow-up CT images were assessed for interval change in the appearance of the infarcts. RESULTS: The mean age of patients was 32 years and the most common mechanism of injury was road traffic accident. The majority (54%) had 25-50% infarction of the spleen. Splenic angiograms were performed in nine patients and seven demonstrated wedge-shaped regions of decreased perfusion corresponding to the infarction seen on CT with no need for intervention. Eleven patients underwent a follow-up CT that demonstrated the following: no significant change in six, near-complete resolution in two, delayed appearance of infarction in one, abscess formation in one, and delayed splenic rupture in one. CONCLUSION: Segmental splenic infarction is a rare manifestation of blunt splenic trauma. The diagnosis is readily made using contrast-enhanced CT. The majority will decrease in size on follow-up CT and resolve without clinical sequelae. Resolution of infarction is also seen and these cases are best described as temporary perfusion defects. Splenic abscess or delayed rupture are uncommon complications that may necessitate angiographic or surgical intervention.

  7. Do TSH, FT3, and FT4 Impact BAT Visualization of Clinical FDG-PET/CT Images?

    Directory of Open Access Journals (Sweden)

    Ryuichi Nishii

    2018-01-01

    Full Text Available Objective. We retrospectively analyzed activated BAT visualization on FDG-PET/CT in patients with various conditions and TH levels to clarify the relationships between visualization of BAT on FDG-PET/CT and the effect of TH. Methods. Patients who underwent clinical FDG-PET/CT were reviewed and we categorized patients into 5 groups: (i thyroid hormone withdrawal (THW group; (ii recombinant human thyrotropin (rhTSH group; (iii hypothyroidism group; (iv hyperthyroidism group; and (v BAT group. A total of sixty-two FDG-PET/CT imaging studies in fifty-nine patients were performed. To compare each group, gender; age; body weight; serum TSH, FT3, and FT4 levels; and outside temperature were evaluated. Results. No significant visualization of BAT was noted in any of the images in the THW, rhTSH, hypothyroidism, and hyperthyroidism groups. All patients in the BAT group were in a euthyroid state. When the BAT-negative and BAT-positive patient groups were compared, it was noted that the minimum and maximum temperature on the day of the PET study and maximum temperature of the one day before the PET study were significantly lower in BAT-positive group than in all those of other groups. Conclusions. Elevated TSH condition before RIT, hyperthyroidism, or hypothyroidism did not significantly impact BAT visualization of clinical FDG-PET/CT images.

  8. comparison of clinical features and CT findings between atypical thymoma and thymic carcinoma

    International Nuclear Information System (INIS)

    Wang Xiangyang; Tan Ye; Chen Juan; Wei Jiahu; Pan Jishun; Du Jun; Zhou Cheng

    2011-01-01

    Objective: To investigate the differences and the similarities of clinical presentations and CT features between type B3 thymoma (atypical thymoma) and type C thymoma (thymic carcinoma) in the WHO classification of thymic epithelial tumors. Methods: Complete CT findings of thirty cases of type B3 and seventeen cases of type C thymic epithelial tumors confirmed by histopathology according to WHO 2004 Classification System and clinical features including the prognosis of each case were reviewed retrospectively. Statistical analyses of the data for the age and the long diameter were performed with Independent-Samples t test between the two groups. Statistical analysis for gender, association with myasthenia gravis, method of the operation, contours, shapes, calcification,necrosis, enhancement pattern of the tumors on CT, presence of mediastinal lymphadenopathy, invasion of mediastinal fat, chest wall, pericardium, great vessel, pleural mediastinum, metastasis to the plural, pleural effusion, distant metastasis were performed with Fisher exact test. Kaplan-Meier method was employed for survival analysis. Results: Clinical data: the average age of type B3 group was significantly younger (t=-2.905, P=0.006). 90.0% (27/30) of patients in type B3 group were complicated by myasthenia gravis, while only 5.9% (1/17) of patients in type C group were complicated by myasthenia gravis. The difference between the two groups was statistically significant (P=0.000). The ratio of complete resection of type B3 group (80.0%) was significantly higher than that in type C group (P=0.001), 70.6% (12/17) of patients in type C group died within 2 years after surgical resection, while only 20.0% (6/30) of patients in type B3 group died within one to nine years after surgical resection. Three years' survival ratio of C group was 29.4%, and five years' survival ratio of C group was lower than 14.7%, which was significantly lower than B3 group five years' survival ratio was 94.7%), which was

  9. Clinical significance of pretreatment FDG PET/CT IN MOBG-avid pediatric neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seo Young; Kim, Yong Il; Cheon, Gi Jeong; Kang, Keon Wook; Chung, June Key; Lee, Dong Soo; Kang, Hyoung Jin; Shin, Hee Young [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, E. Edmund [Seoul National University, Seoul (Korea, Republic of); Rahim, Muhammad Kashif [Nishtar Medical College and Hospital, Multan (Pakistan)

    2017-06-15

    {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) imaging is well known to have clinical significance in the initial staging and response evaluation of the many kinds of neoplasms. However, its role in the pediatric neuroblastoma is not clearly defined. In the present study, the clinical significance of FDG-PET/computed tomography (CT) in 123I- or 131I-metaiodobenzylguanidine (MIBG)-avid pediatric neuroblastoma was investigated. Twenty patients with neuroblastoma who undertook pretreatment FDG PET/CT at our institute between 2008 and 2015 and showed MIBG avidity were retrospectively enrolled in the present study. Clinical information—including histopathology, and serum markers—and several PET parameters—including SUVmax of the primary lesion (Psuv), target-to-background ratio (TBR), metabolic tumor volume (MTV), and coefficient of variation (CV)—were analyzed. The prognostic effect of PET parameters was evaluated in terms of progression-free survival (PFS). Total 20 patients (4.5 ± 3.5 years) were divided as two groups by disease progression. Six patients (30.0 %) experienced disease progression and one patient (5.0 %) died during follow-up period. There were not statistically significant in age, stage, MYCN status, primary tumor size, serum lactate dehydrogenase (LDH), neuron-specific enolase (NSE), and ferritin level between two groups with progression or no progression. However, Psuv (p = 0.017), TBR (p = 0.09), MTV (p = 0.02), and CV (p = 0.036) showed significant differences between two groups. In univariate analysis, PFS was significantly associated with Psuv (p = 0.021) and TBR (p = 0.023). FDG-PET parameters were significantly related with progression of neuroblastoma. FDG-PET/CT may have the potential as a valuable modality for evaluating prognosis in the patients with MIBG-avid pediatric neuroblastoma.

  10. Clinical features and CT scan findings of supratentorial ependymomas and ependymoblastomas

    International Nuclear Information System (INIS)

    Hanakita, Junya; Handa, Hajime

    1984-01-01

    The clinical courses and CT scan findings of 12 cases of supratentorial ependymoma and ependymoblastoma were reviewed. The age of the patient of ependymoma ranged from 3 years to 34 years, with an average age of 16 years. The follow-up time ranged from 2 months to 9 years and 10 months. All of the six patients are still alive. The age of the patients of ependymoblastoma ranged from 7 months to 34 years, with an average age of 17 years. During the follow-up period from 2 weeks to 6 years and 4 months, four patients died. Supratentorial ependymomas and ependymoblastomas show the following characteristic features of CT scans: 1. Calcification: The incidence of calcification was 50% in ependymoma-group, and 100% in ependymoblastoma-group. 2. Cyst formation, ring-enhancement: The cyst formation was noticed in both groups. In ependymoma-group a smooth ring-enhancement pattern and the strongly enhanced mural nodule-like contour were found, but in ependymoblastoma-group, the cyst wall was enhanced in irregular shape. 3. Perifocal edema and mass effect: Considerable mass effect was noticed in both groups. Perifocal edema was slight in many cases of ependymoma-group, but mostly prominent in ependymoblastoma-group. 4. CT scan findings of recurrent tumor: In ependymoma-group, recurrent tumor showed the same characteristics of CT scan as the initial ones. In ependymoblastoma-group, cystic portion decreased in size and irregular shaped solid portion increased in recurrence. (author)

  11. CT in normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Fujita, Katsuzo; Nogaki, Hidekazu; Noda, Masaya; Kusunoki, Tadaki; Tamaki, Norihiko

    1981-01-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings. (author)

  12. Isthmocervical labelling and SPECT/CT for optimized sentinel detection in endometrial cancer: technique, experience and results.

    Science.gov (United States)

    Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H

    2014-08-01

    We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), pnegative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. The influence of interpreters' professional background and experience on the interpretation of multimodality imaging of pulmonary lesions using 18F-3'-deoxy-fluorothymidine and 18F-fluorodeoxyglucose PET/CT.

    Science.gov (United States)

    Xu, Bai-xuan; Liu, Chang-bin; Wang, Rui-min; Shao, Ming-zhe; Fu, Li-ping; Li, Yun-gang; Tian, Jia-he

    2013-01-01

    Based on the results of a recently accomplished multicenter clinical trial for the incremental value of a dual-tracer (18F-FDG and 18F-FLT), dual-modality (PET and CT) imaging in the differential diagnosis of pulmonary lesions, we investigate some issues that might affect the image interpretation and result reporting. The images were read in two separate sessions. Firstly the images were read and reported by physician(s) of the imaging center on completion of each PET/CT scanning. By the end of MCCT, all images collected during the trial were re-read by a collective of readers in an isolated, blinded, and independent way. One hundred sixty two patients successfully passed the data verification and entered into the final analysis. The primary reporting result showed adding 18F-FDG image information did not change the clinical performance much in sensitivity, specifity and accuracy, but the ratio between SUVFLT and SUVFDG did help the differentiation efficacy among the three subgroups of patients. The collective reviewing result showed the diagnostic achievement varied with reading strategies. ANOVA indicated significant differences among (18)F-FDG, (18)F-FLT in SUV (F = 14.239, p = 0.004). CT had almost the same diagnostic performance as 18F-FLT. When the 18F-FDG, 18F-FLT and CT images read in pair, both diagnostic sensitivity and specificity improved. The best diagnostic figures were obtained in full-modality strategy, when dual-tracer PET worked in combination with CT. With certain experience and training both radiologists and nuclear physicians are qualified to read and to achieve the similar diagnostic accuracy in PET/CT study. Making full use of modality combination and selecting right criteria seems more practical than professional back ground and personal experience in the new hybrid imaging technology, at least when novel tracer or application is concerned.

  14. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  15. The repeat CT-findings of the contusional hematoma

    International Nuclear Information System (INIS)

    Tsubokawa, Takashi; Yamada, Jitsuhiro; Tomizawa, Noritami; Takeuchi, Totaro; Shinozaki, Hideo

    1980-01-01

    Twenty-seven cases of traumatic intracerebral hematoma were treated from 1977 to 1979. The intracerebral hematomas are classified into three groups: central type, hematoma within contusional area and contusional hematoma, according to the CT findings and the clinical course. Fourteen of these cases are diagnosed as contusional hematoma which show a normal CT scan, subarachnoidal hemorrhage, subdural hematoma and epidural hematoma without any kind of intracerebral high density in the initial CT scan performed within 6 hours after injury. Ten of the cases were found during conservative treatment; in 2 cases, hematomas were revealed within 24 hours; in 2 more cases within 48 hours, and in 6 cases, within 3 - 5 days following injury. In the other 4 cases, hematoma occurred 1 - 2 days following the emergency evacuation of a subdural hematoma and decompressive craniectomy. Based on the clinical experience outlined above, it is our current practice in diagnosing patients with contusional hematoma to perform repeat CT scanning within 5 - 6 days after injury whenever isodensity or subarachnoidal hemorrhage with a shift in the midline structure is observed in an initial CT scan within 6 hours or whenever an evacuation of the subdural hematoma with decompressive craniectomy is performed. (author)

  16. Rural cerebral CT. It's role in the investigation of headaches

    International Nuclear Information System (INIS)

    Burking, A.

    1997-01-01

    The most common request for cerebral CT is for the investigation of headaches. These requests should not be taken lightly. In many cases CT is extremely valuable in detecting underlying pathology. More so in the rural clinical setting. In 1994, the lower great southern region of W.A. had it's first CT scanning facility installed. A high incidence of pathology was evident in our first 3,000 patients, particularly those presenting with headaches. This paper documents our rural experience. Interesting case studies are provided. These illustrate the fact that old CT technology can still do an admirable job. The facility has helped save lives and raise the level of regional health care. (author)

  17. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  18. Coronary artery imaging with 64-slice spiral CT in atrial fibrillation patients: initial experience

    International Nuclear Information System (INIS)

    Zhou Xuhui; Yan Chaogui; Xie Hongbo; Li Xiangmin; Li Ziping; Meng Quanfei; Chen Xing

    2008-01-01

    Objective: To discuss the clinical value of coronary artery imaging using 64-slice spiral CT in patient with atrial fibrillation. Methods: The images of 31 patients with atrial fibrillation who underwent contrast-enhanced CT coronary angiography were evaluated. The presence of stenosis on each segment of coronary arteries was recorded and their degree of stenosis was measured using the vessel analysis software. Ten patients additionally underwent conventional coronary angiography. The results of conventional coronary angiography were compared with CT coronary angiography of the 10 patients. Results: Image reconstruction was based on absolute timing. The image quality of 364 coronary vessel segments on the images from 31 patients was evaluated and defined as excellent, fine, moderate or poor. The image quality was excellent, fine, moderate and poor in 85, 41, 5, and 8 vessel segments respectively in patient group with heart rate between 47 beat per minent (bpm) and 69 bpm; and in 63, 16, 13, and 15 vessel segments respectively in patent group with heart rate between 70 bpm and 79 bpm;and in 46, 25, 23, and 24 vessel segments in patient group with heart rate between 80 bpm and 105 bpm. There was significant difference among the three patient groups (H=22.08, P<0.01). Comparison was carried out between CT angiographic findings and conventional angiographic findings of the 125 segments of the coronary arteries in the 10 patients who underwent conventional coronary angiography. The sensitivity and specificity of CT angiography for diagnosing vessel with significant coronary stenosis (≥50% narrowing) was 85.0% (17/20) and 95.2% (100/105), respectively. Positive predictive value was 77.3% (17/22), and negative predictive value was 97.1% (100/103). Coronary CTA underestimated the lesions of 3 vessel segments and overestimated the lesions of 5 vessel segments. Conclusion: Coronary artery imaging with 64-slice row CT had clinical value for patients with atrial fibrillation

  19. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  20. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  1. Clinical applications of 2D and 3D CT imaging of the airways - a review

    International Nuclear Information System (INIS)

    Salvolini, Luca; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-01-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  2. Clinical applications of 2D and 3D CT imaging of the airways - a review

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca E-mail: u.salvolini@popcsi.unian.it; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-04-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  3. Evaluation of bone metastases with {sup 18} F- Sodium fluoride PET/CT; initial experience; Evaluacion de metastasis oseas con {sup 18} F-Fluoruro de sodio PET/CT; experiencia inicial

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez C, N.; Serna M, J.A.; Quiroz C, O.; Quinzanos, F.; Valenzuela, J.; Ramirez A, J.L. [Hospital Angeles del Pedregal, Mexico D.F. (Mexico)

    2007-07-01

    The study of NaF-18 PET/CT is the modality with bigger sensitivity and specificity for the bony metastases detection. This additional value of the NaF-18 PET/CT can have a beneficent impact in the clinical handling of the patients with prostate cancer with high risk. (Author)

  4. Combined positron emission tomography/computed tomography (PET/CT) for clinical oncology: technical aspects and acquisition protocols

    International Nuclear Information System (INIS)

    Beyer, T.

    2004-01-01

    Combined PET/CT imaging is a non-invasive means of reviewing both, the anatomy and the molecular pathways of a patient during a quasi-simultaneous examination. Since the introduction of the prototype PET/CT in 1998 a rapid development of this imaging technology is being witnessed. The incorporation of fast PET detector technology into PET/CT designs and the routine use of the CT transmission images for attenuation correction of the PET allow for anato-metabolic whole-body examinations to be completed in less than 30 min. Thus, PET/CT imaging offers a logistical advantage to both, the patient and the clinicians since the two complementary exams - whenever clinically indicated - can be performed almost at the same time and a single integrated report can be created. Nevertheless, a number of pit-falls, primarily from the use of CT-based attenuation correction, have been identified and are being addressed through optimized acquisition protocols. It is fair to say, that PET/CT has been integrated in the diagnostic imaging arena, and in many cases has led to a close collaboration between different, yet complementary diagnostic and therapeutic medical disciplines. (orig.)

  5. CT saber-sheath trachea. Correlation with clinical, chest radiographic and functional findings

    International Nuclear Information System (INIS)

    Trigaux, J.P.; Hermes, G.; Dubois, P.; Beers, B. van; Delaunois, L.; Jamart, J.

    1994-01-01

    The diagnosis of saber-sheath trachea is easy at CT due to its cross-sectional imaging, but the significance of this CT sign has not been evaluated in the diagnosis of chronic obstructive pulmonary disease (COPD). Various signs of COPD were compared between a series of 20 patients with a saber-sheath trachea at CT (tracheal index ≤66%) and a group of 20 pneumologic control patients without saber-sheath trachea (tracheal index ≥70%). These signs include clinical and standard radiographic indices of COPD, sternum-spine distance and 3 functional tests of COPD: forced expiratory volume in one second, carbon monoxide diffusing lung capacity, and funtional residual capacity (FRC). A significant difference was found between the 2 groups, concerning the values of FRC and of sternum-spine distance (p -2 ). The tracheal index was significantly correlated with the FRC values and with the sternum-spine distance. No other significant difference was observed. It is concluded that saber-sheath trachea is basically a sign of hyperinflation. (orig./MG)

  6. Reappraisal of Pediatric Diastatic Skull Fractures in the 3-Dimensional CT Era: Clinical Characteristics and Comparison of Diagnostic Accuracy of Simple Skull X-Ray, 2-Dimensional CT, and 3-Dimensional CT.

    Science.gov (United States)

    Sim, Sook Young; Kim, Hyun Gi; Yoon, Soo Han; Choi, Jong Wook; Cho, Sung Min; Choi, Mi Sun

    2017-12-01

    Diastatic skull fractures (DSFs) in children are difficult to detect in skull radiographs before they develop into growing skull fractures; therefore, little information is available on this topic. However, recent advances in 3-dimensional (3D) computed tomography (CT) imaging technology have enabled more accurate diagnoses of almost all forms of skull fracture. The present study was undertaken to document the clinical characteristics of DSFs in children and to determine whether 3D CT enhances diagnostic accuracy. Two hundred and ninety-two children younger than 12 years with skull fractures underwent simple skull radiography, 2-dimensional (2D) CT, and 3DCT. Results were compared with respect to fracture type, location, associated lesions, and accuracy of diagnosis. DSFs were diagnosed in 44 (15.7%) of children with skull fractures. Twenty-two patients had DSFs only, and the other 22 had DSFs combined with compound or mixed skull fractures. The most common fracture locations were the occipitomastoid (25%) and lambdoid (15.9%). Accompanying lesions consisted of subgaleal hemorrhages (42/44), epidural hemorrhages (32/44), pneumocephalus (17/44), and subdural hemorrhages (3/44). A total of 17 surgical procedures were performed on 15 of the 44 patients. Fourteen and 19 patients were confirmed to have DSFs by skull radiography and 2D CT, respectively, but 3D CT detected DSFs in 43 of the 44 children (P skull radiography or 2D CT for detecting DSFs. This finding indicates that 3D CT should be used routinely rather than 2D CT for the assessment of pediatric head trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  8. FDG PET/CT in infection and inflammation—current and emerging clinical applications

    International Nuclear Information System (INIS)

    Vaidyanathan, S.; Patel, C.N.; Scarsbrook, A.F.; Chowdhury, F.U.

    2015-01-01

    Integrated positron emission tomography/computed tomography (PET/CT) with the glucose analogue, 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG), is an evolving hybrid imaging technique in the evaluation of an important and diverse group of pathological conditions, which are characterised by infection and aseptic inflammation. With a rapidly expanding body of evidence, it is being increasingly recognised that, in addition to its established role in oncological imaging, FDG PET/CT also has clinical utility in suspected infection and inflammation. The technique can identify the source of infection or inflammation in a timely fashion ahead of morphological changes on conventional anatomical imaging techniques, such as computed tomography (CT) and magnetic resonance imaging (MRI), map the extent and severity of disease, identify sites for tissue sampling, and assess therapy response. FDG PET/CT exhibits distinct advantages over traditional radionuclide imaging techniques in terms of shorter duration of examination, higher spatial resolution, non-invasive nature of acquisition, ability to perform quantitative analyses, and the provision of a synergistic combination of functional and anatomical imaging. With the use of illustrative clinico-radiological cases, this article discusses the current and emerging evidence for the use of FDG PET/CT in a broad spectrum of disorders, such as fever of unknown origin, sarcoidosis, large vessel vasculitis, musculoskeletal infections, joint prosthesis or implant-related complications, human immunodeficiency virus (HIV)-related infections, and miscellaneous indications, such as IgG4-related systemic disease. It will also briefly summarise the role of more novel tracers such as FDG-labelled leukocytes and gallium-68 PET tracers in this arena

  9. "Clinical-CT mismatch" and the response to systemic thrombolytic therapy in acute ischemic stroke.

    Science.gov (United States)

    Kent, David M; Hill, Michael D; Ruthazer, Robin; Coutts, Shelagh B; Demchuk, Andrew M; Dzialowski, Imanuel; Wunderlich, Olaf; von Kummer, Rudiger

    2005-08-01

    Mismatch between clinical deficits and imaging lesions in acute stroke has been proposed as a method of identifying patients who have hypoperfused but still have viable brain, and may be especially apt to respond to reperfusion therapy. We explored this hypothesis using a combined database including 4 major clinical trials of intravenous (IV) thrombolytic therapy. To determine what the radiological correlates of a "matched" functional deficit are, we calculated the relationship between the ASPECT score of the 24-hour (follow-up) CT scan and the 24-hour National Institutes of Health Stroke Scale (NIHSS) score on the subsample with ASPECT scores performed at this time (n=820). Based on this empirical relationship, we computed the absolute difference between the observed baseline ASPECT score and the "expected" score (ie, matched) based on baseline NIHSS for all patients (n=2131). We tested whether patients with better than expected baseline ASPECTS were more likely to benefit from IV recombinant tissue plasminogen activation (rtPA). At 24 hours, there was a strong, linear, negative correlation between NIHSS and ASPECTS (r2=0.33, P<0.0001); on average, an increase of 10 points on NIHSS corresponded to a decrease of approximately 3 points on ASPECTS. At baseline, the average degree of mismatch between the observed and "expected" ASPECTS was 2.1 points (interquartile range, 1.0 to 3.4). However, multiple analyses failed to reveal a consistent relationship between the degree of clinical-CT mismatch at baseline and a patient's likelihood of benefiting from IV rtPA. Clinical-CT mismatch using ASPECT scoring does not reliably identify patients more or less likely to benefit from IV rtPA.

  10. Clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Goo, Eun Hoe [Dept. Radiological Science, Cheongju University, Cheongju (Korea, Republic of)

    2016-11-15

    The purpose of this study was to assess clinical application of lower extremity CTA and lower extremity perfusion CT as a method of diagnostic for lower extremity atherosclerotic obliterans. From January to July 2016, 30 patients (mean age, 68) were studied with lower extremity CTA and lower extremity perfusion CT. 128 channel multi-detector row CT scans were acquired with a CT scanner (SOMATOM Definition Flash, Siemens medical solution, Germany) of lower extremity perfusion CT and lower extremity CTA. Acquired images were reconstructed with 3D workstation (Leonardo, Siemens, Germany). Site of lower extremity arterial occlusive and stenosis lesions were detected superficial femoral artery 36.6%, popliteal artery 23.4%, external iliac artery 16.7%, common femoral artery 13.3%, peroneal artery 10%. The mean total DLP comparison of lower extremity perfusion CT and lower extremity CTA, 650 mGy-cm and 675 mGy-cm, respectively. Lower extremity perfusion CT and lower extremity CTA were realized that were never be two examination that were exactly the same legions. Future through the development of lower extremity perfusion CT soft ware programs suggest possible clinical applications.

  11. Scatter correction using a primary modulator on a clinical angiography C-arm CT system.

    Science.gov (United States)

    Bier, Bastian; Berger, Martin; Maier, Andreas; Kachelrieß, Marc; Ritschl, Ludwig; Müller, Kerstin; Choi, Jang-Hwan; Fahrig, Rebecca

    2017-09-01

    Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is inserted between the X-ray source and the object. This modulation enables estimation of the scatter in the projection domain by optimizing an objective function with respect to the scatter estimate. Up to now the approach has not been implemented on a clinical angiography C-arm CT system. In our work, the iPMSE method is transferred to a clinical C-arm CBCT. Additional processing steps are added in order to compensate for the C-arm scanner motion and the automatic X-ray tube current modulation. These challenges were overcome by establishing a reference modulator database and a block-matching algorithm. Experiments with phantom and experimental in vivo data were performed to evaluate the method. We show that scatter correction using primary modulation is possible on a clinical C-arm CBCT. Scatter artifacts in the reconstructions are reduced with the newly extended method. Compared to a scan with a narrow collimation, our approach showed superior results with an improvement of the contrast and the contrast-to-noise ratio for the phantom experiments. In vivo data are evaluated by comparing the results with a scan with a narrow collimation and with a constant scatter correction approach. Scatter correction using primary modulation is possible on a clinical CBCT by compensating for the scanner motion and the tube current modulation. Scatter artifacts could be reduced in the reconstructions of phantom scans and in experimental in vivo data. © 2017 American Association of Physicists in Medicine.

  12. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results; Klinischer Einsatz der digitalen retrospektiven Bildfusion von CT, MRT, FDG-PET und SPECT - Anwendungsgebiete und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R. [Campus Virchow-Klinikum, Klinik fuer Strahlenheilkunde, Charite, Universitaetsmedizin Berlin (Germany); Rohlfing, T. [Dept. of Neurosurgery, Stanford Univ. (United States); Hosten, N. [Inst. fuer Diagnostische Radiologie, Ernst-Moritz-Arndt-Univ. Greifswald (Germany)

    2004-12-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  13. FDG-PET/CT in oncology. German guideline

    International Nuclear Information System (INIS)

    Krause, B.J.; Beyer, T.; Bockisch, A.; Delbeke, D.; Kotzerke, J.; Minkov, V.; Reiser, M.; Willich, N.

    2007-01-01

    FDG-PET/CT examinations combine metabolic and morphologic imaging within an integrated procedure. Over the past decade PET/CT imaging has gained wide clinical acceptance in the field of oncology. This FDG-PET/CT guideline focuses on indications, data acquisition and processing as well as documentation of FDG-PET/CT examinations in oncologic patients within a clinical and social context specific to Germany. Background information and definitions are followed by examples of clinical and research applications of FDG-PET/CT. Furthermore, protocols for CT scanning (low dose and contrast-enhanced CT) and PET emission imaging are discussed. Documentation and reporting of examinations are specified. Image interpretation criteria and sources of errors are discussed. Quality control for FDG and PET/CT-systems, qualification requirements of personnel as well as legal aspects are presented. (orig.)

  14. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  15. Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, B. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Keller, H. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, 150 College Street, Toronto, Ontario M5S 3E2 (Canada); Jaffray, D.; Coolens, C. [Department of Radiation Physics, Princess Margaret Cancer Center, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, University of Toronto, 150 College Street, Toronto, Ontario M5S 3E2 (Canada); Techna Institute, University Health Network, 124-100 College Street, Toronto, Ontario M5G 1L5 (Canada)

    2013-08-15

    Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from

  16. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Prevalence and clinical significance of extravascular incidental findings in patients undergoing CT cervico-cerebral angiography

    International Nuclear Information System (INIS)

    Crockett, Matthew Thomas; Murphy, Blathnaid; Smith, Jennifer; Kavanagh, Eoin Carl

    2015-01-01

    Highlights: • CT cervico-cerebral angiography (CTCCA) is a commonly performed study for assessment of vascular pathologies of head and neck. • This study assessed the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. • This study demonstrated the presence of clinically significant incidental findings in 14% of patients undergoing CTCCA with 8% of these findings deemed to be highly significant. 19% of patients with highly clinically significant findings did not receive appropriate follow up. • A standardised method of reporting incidental findings, such as that used in this paper is suggested to aid radiologists and referring physicians in recording and communicating these findings. - Abstract: Introduction: CT cervico-cerebral angiography (CTCCA) is now the first line diagnostic imaging modality for the majority of vascular pathologies of the head and neck with diagnostic value comparable to or better than traditional angiographic techniques. The aim of this study was to assess the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. Materials and methods: A retrospective review of the CTCCA reports of 302 consecutive patients from 2009 to 2013 was undertaken. Extravascular incidental findings were classified, according to an adaptation of the CT colonography data and reporting system (CRADS), as EV1–EV4. EV1 = no incidental findings, EV2 = clinically insignificant incidental finding, EV3 = incidental finding of intermediate clinical significance, EV4 = highly clinically significant finding. Follow up of the electronic medical records of patients with EV3 or EV4 findings was undertaken to determine subsequent management. Results: Potentially clinically significant findings were demonstrated in 14.2% of patients with 8.6% of patients having a highly clinically significant finding. 4 incidental findings were confirmed to be malignant lesions and 5

  18. FDG PET/CT in clinical oncology. Case based approach with teaching points

    Energy Technology Data Exchange (ETDEWEB)

    Mihailovic, Jasna [Novi Sad Univ. (Serbia). Dept. of Nuclear Medicine; Goldsmith, Stanley J. [Weill Cornell Medical College, New York, NY (United States). Div. of Nuclear Medicine and Molecular Imging; Killeen, Ronan P. [St. Vincents Univ. Hospital, Dublin (Ireland)

    2012-07-01

    Organized according to the role of FDG PET/CT in the evaluation and management of oncology patients. 100 informative cases reflecting the issues that clinicians address in their daily practice. Ideal for all newcomers to the field, whether medical students, radiology, nuclear medicine, or oncology fellows, or practicing physicians. FDG PET/CT has rapidly emerged as an invaluable combined imaging modality that can identify tumors on the basis of not only anatomical alterations but also metabolic activity, thus allowing the detection of lesions that would otherwise be too small to distinguish. This book, comprising a collection of images from oncology cases, is organized according to the role of FDG PET/CT in the evaluation and management of oncology patients, and only secondarily by organ or tumor entity. In this way, it reflects the issues that clinicians actually address in their daily practice, namely: identification of an unknown or unsuspected primary; determination of the extent of disease; evaluation of response to therapy; and surveillance after response, i.e., detection of recurrent disease. In total, 100 cases involving different primary tumors are presented to illustrate findings in these different circumstances. FDG PET/CT in Clinical Oncology will be of great value to all newcomers to this field, whether medical students, radiology, nuclear medicine, or oncology fellows, or practicing physicians.

  19. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  20. Patient recruitment into a multicenter randomized clinical trial for kidney disease: report of the focal segmental glomerulosclerosis clinical trial (FSGS CT).

    Science.gov (United States)

    Ferris, Maria; Norwood, Victoria; Radeva, Milena; Gassman, Jennifer J; Al-Uzri, Amira; Askenazi, David; Matoo, Tej; Pinsk, Maury; Sharma, Amita; Smoyer, William; Stults, Jenna; Vyas, Shefali; Weiss, Robert; Gipson, Debbie; Kaskel, Frederick; Friedman, Aaron; Moxey-Mims, Marva; Trachtman, Howard

    2013-02-01

    We describe the experience of the focal segmental glomerulosclerosis clinical trial (FSGS CT) in the identification and recruitment of participants into the study. This National Institutes of Health funded study, a multicenter, open-label, randomized comparison of cyclosporine versus oral dexamethasone pulses plus mycophenolate mofetil, experienced difficulty and delays meeting enrollment goals. These problems occurred despite the support of patient advocacy groups and aggressive recruitment strategies. Multiple barriers were identified including: (1) inaccurate estimates of the number of potential incident FSGS patients at participating centers; (2) delays in securing one of the test agents; (3) prolonged time between IRB approval and execution of a subcontract (mean 7.5 ± 0.8 months); (4) prolonged time between IRB approval and enrollment of the first patient at participating sites (mean 19.6 ± 1.4 months); and (5) reorganization of clinical coordinating core infrastructure to align resources with enrollment. A Web-based anonymous survey of site investigators revealed site-related barriers to patient recruitment. The value of a variety of recruitment tools was of marginal utility in facilitating patient enrollment. We conclude that improvements in the logistics of study approval and regulatory start-up and testing of promising novel agents are important factors in promoting enrollment into randomized clinical trials in nephrology. © 2013 Wiley Periodicals, Inc.

  1. F-18 FDG PET/CT in 26 patients with SAPHO syndrome: a new vision of clinical and bone scintigraphy correlation.

    Science.gov (United States)

    Sun, Xiaochuan; Li, Chen; Cao, Yihan; Shi, Ximin; Li, Li; Zhang, Weihong; Wu, Xia; Wu, Nan; Jing, Hongli; Zhang, Wen

    2018-05-22

    Whole-body bone scintigraphy (WBBS) and MRI are widely used in assessment of patients with synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO) syndrome. However, the value of F-18 fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG PET/CT) in SAPHO syndrome was unclear. The aim of this study was to characterize the manifestation of SAPHO syndrome on 18 F-FDG PET/CT and explore its relationship with clinical symptoms and WBBS. Twenty-six patients who suffered from SAPHO syndrome and had undergone whole-body 18 F-FDG PET/CT were recruited in Peking Union Medical College Hospital from 2004 to 2016. Clinical manifestations and laboratory findings were recorded for all patients. Imaging data on 18F-FDG PET/CT and WBBS were collected and analyzed retrospectively. All the 26 patients (20 females and 6 males) exhibited skeletal abnormalities on 18 F-FDG PET/CT. Multiple skeletal lesions affecting the anterior chest wall or spine with low to moderate 18 F-FDG uptake and coexistence of osteolysis and osteosclerosis presented as the typical features of SAPHO syndrome. Sixteen (61.5%) patients had abnormal 18 F-FDG uptake outside the osteoarticular system. PET scan had moderate to substantial agreement with CT and WBBS in revealing lesions in the anterior chest wall and axial skeleton. Nonetheless, the correlation between increased 18 F-FDG uptake and clinical symptoms was weak. SAPHO syndrome exhibits characteristic features on 18 F-FDG PET/CT. It showed comparable capacity in revealing skeletal lesions with bone scintigraphy.

  2. Dynamic contrast-enhanced MR imaging in osteoid osteoma: relationships with clinical and CT characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Pottecher, P. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Hopital du Bocage, Department of Vascular, Oncologic and Interventional Radiology, Dijon (France); Sibileau, E.; Hamze, B.; Parlier, C.; Laredo, J.D.; Bousson, V. [Hopital Lariboisiere, AP-HP, Department of Osteoarticular Radiology, Paris (France); Aho, S. [Hopital du Bocage, Hospital Hygiene and Epidemiology unit, Dijon (France)

    2017-07-15

    To correlate dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) features to clinical and computed tomography (CT) morphological features of osteoid osteoma (OO). Our institutional review board approved this retrospective study, waiving the need for informed consent. We included the 102 patients treated with interstitial laser ablation for histologically documented OO at our institution in 2008-2013. DCE-MRI variables were the time-enhancement pattern and rising slope (Slope{sub rise}) and CT variables were the bone and segment involved (OO{sub bone} and OO{sub segment,} respectively), OO location relative to the native cortex (OO{sub cortex}), nidus surface area, vessel sign, and largest neighboring-vessel diameter (Dmax{sub vessel}). Descriptive statistics and correlations linking DCE-MRI findings to clinical and CT characteristics were computed. DCE-MRI showed early arterial peak enhancement in 95 (93%) cases, with a mean Slope{sub rise} of 9.30 ± 8.10. CT visualized a vessel sign in 84 (82%) cases with a mean Dmax{sub vessel} of 1.10 ± 0.60 mm. By univariate analysis, Slope{sub rise} correlated significantly with pain duration and Dmax{sub vessel} (r = 0.30, P = 0.003; and r = 0.22, P = 0.03; respectively). Analysis of variance showed that Slope{sub rise} correlated significantly with OO{sub bone} (P < 0.001), with a steeper slope for OOs located in short or flat bones. This study suggests more abundant vascularization of OOs with long-lasting pain and location on short or flat bones. (orig.)

  3. A new clinical tool for the quantification of myocardial CT perfusion imaging in patients with suspected Ischemic Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Muñoz, A.; Dux-Santoy Hurtado, L.; Rodriguez Palomares, J.L.; Piella Fenoy, G.

    2016-07-01

    In the clinical practice, the evaluation of myocardial perfusion by using Computed Tomography (CT) Imaging is usually performed visually or semi-quantitatively. The scarcity of quantitative perfusion data not always allows a proper diagnose of patients which are suspected of suffering from some diseases, such as Ischemic Heart Disease (IHD). In this work, a clinical tool for the automatic quantification of myocardial perfusion in patients with suspected IHD is proposed. Myocardial perfusion is assessed based on a combined diagnosis protocol (CT/CTP protocol) which involves the acquisition of two contrastenhanced CT images, one obtained at rest and another acquired under pharmacological stress. The clinical tool allows the automatic quantification of perfusion in different myocardial segments defined according to the 16-AHA-segmentation model of the left ventricle, by providing the mean of Hounsfield Units in those regions. Based on this analysis, the clinicians can compare the values at baseline and at hyperemia, and they can better determine hypoperfusion defects in patients with IHD. The validation of the clinical tool was performed by comparing automatic and manual perfusion measurements of 10 patients with suspected IHD who were previously assessed with Single Photon Emission Computed Tomography (SPECT) for perfusion analysis. A strong linear correlation was found between the automatic and manual results. Afterwards, perfusion defects obtained from CT/CTP protocol were compared to perfusion defects from SPECT, to assess the applicability of this clinical tool for the diagnosis of IHD. (Author)

  4. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    International Nuclear Information System (INIS)

    Verma, Divya Ratan; Pershad, Yash; Pershad, Ashish; Fang, Kenith; Gellert, George; Morris, Michael F.

    2016-01-01

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low ( 75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had significantly improved accuracy in identifying the annulus.

  5. CT in three cases of syringomyelia

    International Nuclear Information System (INIS)

    Ugawa, Yoshikazu; Sakuta, Manabu; Yagishita, Akira; Inoue, Kiyoharu.

    1983-01-01

    We presented the results of our experience with metrizamide computed tomographic myelography (MCTM) and myelography in three cases of syringomyelia. In case 1, MCTM revealed Chiari malformation, even though this malformation was not clear in the myelography. In case 3, Chiari malformation was apparent in MCTM and in the myelography. In case 1, CT of the spinal cord without enhancement (plain CT) showed a syrinx in the cervical spinal cord, and MCTM made the syrinx clearer with enhancement. MCTM also demonstrated a cavity at the levels of Th 6 and L 1 of the vertebra. In case 2, a syrinx was disclosed in MCTM, in spite of normal myelography. In case 3, myelography demonstrated a spinal cord swelling. MCTM made a syrinx less clear than plain CT. Not only MCTM but also plain CT is an excellent method for the recognition of syringomyelia. The non-invasive plain CT is the first choice of the examinations in cases with syrinogomyelia, because MCTM may make a syrinx obscure. CT and MCTM have to be performed at many levels of the spinal cord in case with syringomyelia. CT or MCTM may demonstrate a syrinx or a cavity at the levels of the spinal cord, where no syrinx is suspected to exist by clinical features, as well as at the levels appearing normal in the myelography. (author)

  6. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  7. Translation of field-reversed configurations in the FRX C/T experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rej, D.J.; Armstrong, W.T.; Chrien, R.E.; Klingner, P.L.; Linford, R.K.; McKenna, K.F.; Milroy, R.D.; Sherwood, E.G.; Siemon, R.E.; Tuszewski, M.

    1984-01-01

    One of the unique features inherent to compact toroids is the potential ability to translate the plasma along its geometric axis. CT translation has proven useful in reactor design studies, and has been the focus of several experimental investigations. In this paper, we report on the initial results from translation experiments performed with the field-reversed configuration (FRC) plasmas generated in the FRX-C/T device.

  8. Translation of field-reversed configurations in the FRX C/T experiment

    International Nuclear Information System (INIS)

    Rej, D.J.; Armstrong, W.T.; Chrien, R.E.

    1984-01-01

    One of the unique features inherent to compact toroids is the potential ability to translate the plasma along its geometric axis. CT translation has proven useful in reactor design studies, and has been the focus of several experimental investigations. In this paper, we report on the initial results from translation experiments performed with the field-reversed configuration (FRC) plasmas generated in the FRX-C/T device

  9. Introducing a Clinical Practice Guideline Using Early CT in the Diagnosis of Scaphoid and Other Fractures

    Directory of Open Access Journals (Sweden)

    Pincus, Steven

    2009-11-01

    Full Text Available Objective: We developed and implemented clinical practice guideline (CPG using computerized tomography (CT as the initial imaging method in the emergency department management of scaphoid fractures. We hypothesized that this CPG would decrease unnecessary immobilization and lead to earlier return to work.Methods: This observational study evaluated implementation of our CPG, which incorporated early wrist CT in patients with “clinical scaphoid fracture”: a mechanism of injury consistent with scaphoid fracture, anatomical snuff box tenderness, and normal initial plain x-rays. Outcome measures were the final diagnosis as determined by orthopaedic review of the clinical and imaging data. Patient outcomes included time to return to work and patient satisfaction as determined by telephone interview at ten days.Results: Eighty patients completed the study protocol in a regional emergency department.In this patient population CT detected 28 fractures in 25 patients, including six scaphoid fractures, five triquetral fractures, four radius fractures, and 13 other related fractures. Fifty-three patients had normal CT. Eight of these patients had significant ongoing pain at follow up and had an MRI, with only two bone bruises identified. The patients with normal CTs avoided prolonged immobilization (mean time in plaster 2.7 days and had no or minimal time off work (mean 1.6 days. Patient satisfaction was an average 4.2/5.Conclusion: This CPG resulted in rapid and accurate management of patients with suspected occult scaphoid injury, minimized unnecessary immobilization and was acceptable to patients.[WestJEM. 2009;10(4:227-232.

  10. Clinical Outcomes of Patients Receiving Integrated PET/CT-Guided Radiotherapy for Head and Neck Carcinoma

    International Nuclear Information System (INIS)

    Vernon, Matthew R.; Maheshwari, Mohit; Schultz, Christopher J.; Michel, Michelle A.; Wong, Stuart J.; Campbell, Bruce H.; Massey, Becky L.; Wilson, J. Frank; Wang Dian

    2008-01-01

    Purpose: We previously reported the advantages of 18 F-fluorodeoxyglucose-positron emission tomography (PET) fused with CT for radiotherapy planning over CT alone in head and neck carcinoma (HNC). The purpose of this study was to evaluate clinical outcomes and the predictive value of PET for patients receiving PET/CT-guided definitive radiotherapy with or without chemotherapy. Methods and Materials: From December 2002 to August 2006, 42 patients received PET/CT imaging as part of staging and radiotherapy planning. Clinical outcomes including locoregional recurrence, distant metastasis, death, and treatment-related toxicities were collected retrospectively and analyzed for disease-free and overall survival and cumulative incidence of recurrence. Results: Median follow-up from initiation of treatment was 32 months. Overall survival and disease-free survival were 82.8% and 71.0%, respectively, at 2 years, and 74.1% and 66.9% at 3 years. Of the 42 patients, seven recurrences were identified (three LR, one DM, three both LR and DM). Mean time to recurrence was 9.4 months. Cumulative risk of recurrence was 18.7%. The maximum standard uptake volume (SUV) of primary tumor, adenopathy, or both on PET did not correlate with recurrence, with mean values of 12.0 for treatment failures vs. 11.7 for all patients. Toxicities identified in those patients receiving intensity modulated radiation therapy were also evaluated. Conclusions: A high level of disease control combined with favorable toxicity profiles was achieved in a cohort of HNC patients receiving PET/CT fusion guided radiotherapy plus/minus chemotherapy. Maximum SUV of primary tumor and/or adenopathy was not predictive of risk of disease recurrence

  11. Clinical evaluation of CT-guided stereotaxic evacuation of hypertensive intracerebral hematomas

    International Nuclear Information System (INIS)

    Kimura, Masato; Yoshinaga, Shiya; Nakayama, Yoshiya; Hirakawa, Toshihiko; Tanaka, Akira; Tomonaga, Masamichi

    1989-01-01

    The clinical results of CT-guided stereotaxic evacuation of hypertensive intracerebral hematomas which had been done in our department during the last 16 months were evaluated. They included 18 cases; 8 of thalamic, 9 of putaminal and one of cerebellar hematoma. The patients were 11 males and 7 females, with an average age of 57. The time interval from oneset to surgery was 1-21 days, 9.5 days on average. The hematoma volume estimated on a CT scan was 6-35 ml and the average rate of hematoma removal by surgery was 75%. Intraoperative monitoring with ultrasonography and postoperative infusion of Urokinase increased the removal rate. In 14 cases, the mental ability and motor function improved within days after surgery and rehabilitation was started within a short period. However, the recovery in aged people was generally poor. Rebleeding occurred postoperatively in one case, necessitating a subsequent craniotomy. (author)

  12. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California 90095 (United States); Department of Radiation Oncology, University of California San Diego, San Diego, California 92093 (United States); Philips Healthcare System, Cleveland, Ohio 44143 (United States); Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States)

    2012-12-15

    Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose

  13. CT quantitative diagnosis in fatty liver: a clinical study

    International Nuclear Information System (INIS)

    He Wen; Qian Linxue; Zhao Jixue; Ma Daqing; Feng Jie; Hu Zhihai

    2001-01-01

    Objective: To establish the CT criteria of quantitative diagnosis for liver steatosis by means of studying the CT features of fatty liver cases proven histologically. Methods: Twenty-eight cases of fatty liver were underwent non-enhanced CT scan, and the attenuation of liver parenchyma was measured. To differentiate the degree of fatty liver, the mean CT value and the relative density of hepatic vessels were observed. The quantitative diagnosis was made according to the CT number threshold and the criteria of relative density of hepatic vessels, respectively. Results: Among the 28 cases, there were 17 cases of mild steatosis with mean CT number of 46 HU (32-65 HU), 7 cases of middle degree fatty liver with mean CT number of 28 HU (15-38 HU), and 4 cases of sever fatty liver with mean CT number of 0.2 HU (-7-11 HU). For the relative density of hepatic vessels, 16 of the 17 cases of mild fatty liver had a appearance of hepatic vessels immersion and 1 mild case had reverse hepatic vessels display, 6 of 7 middle degree cases had reverse hepatic vessels display with 1 case having the appearance of hepatic vessels immersion, and all the 4 case of sever steatosis had the appearance of reverse hepatic vessels display with sharp contrast between vessels and the liver parenchyma. The accuracy of quantitative diagnosis was 65.9% and 93.1% by means of criteria of CT number threshold and relative density of hepatic vessels, respectively (x 2 = 7.153, P < 0.01). Conclusion: The criteria of relative density of hepatic vessels is more reliable than that of CT number threshold in quantitative diagnosis of fatty liver

  14. [Clinical value of CT-guided high frequency-induced thermotherapy as a treatment for intrahepatic cholangiocarcinoma].

    Science.gov (United States)

    Fan, Wei-Jun; Zhang, Liang; Gu, Yang-Kui; Wang, Li-Gang; Ouyang, Yu-Shu

    2008-07-01

    To evaluate the therapeutic effect of CT-guided high frequency-induced thermotherapy (HiTT) for intrahepatic cholangiocarcinoma. Seventeen patients of intrahepatic cholangiocarcinoma with 21 lesions underwent comprehensive treatment with HiTT as the principle approach. As to the patients with obstructive jaundice, percutaneous trans-hepatic cholangial drainage (PTCD) or bile duct endoprosthesis placement was performed first to improve the liver function, then HiTT was performed; and patients without obstructive jaundice underwent CT-guided HiTT directly, 1-2 weeks later, chemotherapy was given for 4 - 6 courses. CT scan 1 week after HiTT showed a short-term achievement rate of 100% (17/17), and the single puncture in situ ablation rate was 76.1% (16/21). The average life span in the near future was 13.5 months. The adverse effects included topo-bleeding, pain after procedure, liver function damage, defervescence, etc. All the patients recovered after symptomatic treatment. The clinical value of CT-guided HiTT for intrahepatic cholangiocarcinoma is obvious.

  15. 18F-FDG PET/CT in the clinical management of patients with lymphoma.

    Science.gov (United States)

    Tamayo, P; Martín, A; Díaz, L; Cabrero, M; García, R; García-Talavera, P; Caballero, D

    The aim of this work was to review the current recommendations for staging and response assessment of patients with Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL) in routine clinical practice after chemotherapy and/or stem cell transplantation. A five-point scale (5-PS) from the First International Workshop on PET in Lymphoma in Deauville, France, in 2009, was recommended as the standard tool to score imaging to assess treatment response in patients with lymphoma using 18 F-Fluorodeoxyglucose (FDG) PET/CT. Following the recommendations of the 11th and 12th International Conferences on Malignant Lymphoma held in Lugano (Switzerland), in 2011 and 2013, respectively, a consensus (the so-called Lugano Classification) was reached regarding the use of PET/CT for staging and response assessment in FDG-avid lymphomas. As a result, 18 F-FDG PET/CT was formally incorporated into standard staging for FDG-avid lymphomas. A bone marrow biopsy is no longer indicated for the routine staging of HL and most diffuse large B-cell lymphomas. PET/CT will be used to assess response in FDG-avid histologies using the 5-point scale. The recent introduction of biological agents with immune mechanisms requires flexibility in interpretations of the Lugano criteria due to tumour flare or a pseudo-progression effect produced by these agents. Provisional criteria have been proposed (Lymphoma Response to Immunomodulatory Therapy Criteria) with the introduction of the term 'Indeterminate Response' in order to identify this phenomenon until confirmed as flare/pseudoprogression or true progression. All these recommendations will improve evaluations of patients with lymphoma, and allow comparison of results from clinical practice and trials. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

    International Nuclear Information System (INIS)

    Wang, Ge; Xi, Yan; Gjesteby, Lars; Getzin, Matthew; Yang, Qingsong; Cong, Wenxiang; Kalra, Mannudeep; Murugan, Venkatesh; Vannier, Michael

    2015-01-01

    Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine

  17. Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ge, E-mail: wangg6@rpi.edu; Xi, Yan; Gjesteby, Lars; Getzin, Matthew; Yang, Qingsong; Cong, Wenxiang [Biomedical Imaging Center/Cluster, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Kalra, Mannudeep; Murugan, Venkatesh [Department of Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts 02114 (United States); Vannier, Michael [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States)

    2015-10-15

    Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine.

  18. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    International Nuclear Information System (INIS)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G

    2015-01-01

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits

  19. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    Energy Technology Data Exchange (ETDEWEB)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G [Baystate Health Systems, Inc., Springfield, MA (United States)

    2015-06-15

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

  20. Inter-radiologist agreement for CT scoring of pediatric splenic injuries and effect on an established clinical practice guideline.

    Science.gov (United States)

    Leschied, Jessica R; Mazza, Michael B; Davenport, Matthew; Chong, Suzanne T; Smith, Ethan A; Hoff, Carrie N; Ladino-Torres, Maria F; Khalatbari, Shokoufeh; Ehrlich, Peter F; Dillman, Jonathan R

    2016-02-01

    The American Pediatric Surgical Association (APSA) advocates for the use of a clinical practice guideline to direct management of hemodynamically stable pediatric spleen injuries. The clinical practice guideline is based on the CT score of the spleen injury according to the American Association for the Surgery of Trauma (AAST) CT scoring system. To determine the potential effect of radiologist agreement for CT scoring of pediatric spleen injuries on an established APSA clinical practice guideline. We retrospectively analyzed blunt splenic injuries occurring in children from January 2007 to January 2012 at a single level 1 trauma center (n = 90). Abdominal CT exams performed at clinical presentation were reviewed by four radiologists who documented the following: (1) splenic injury grade (AAST system), (2) arterial extravasation and (3) pseudoaneurysm. Inter-rater agreement for AAST injury grade was assessed using the multi-rater Fleiss kappa and Kendall coefficient of concordance. Inter-rater agreement was assessed using weighted (AAST injury grade) or prevalence-adjusted bias-adjusted (binary measures) kappa statistics; 95% confidence intervals were calculated. We evaluated the hypothetical effect of radiologist disagreement on an established APSA clinical practice guideline. Inter-rater agreement was good for absolute AAST injury grade (kappa: 0.64 [0.59–0.69]) and excellent for relative AAST injury grade (Kendall w: 0.90). All radiologists agreed on the AAST grade in 52% of cases. Based on an established clinical practice guideline, radiologist disagreement could have changed the decision for intensive care management in 11% (10/90) of children, changed the length of hospital stay in 44% (40/90), and changed the time to return to normal activity in 44% (40/90). Radiologist agreement when assigning splenic AAST injury grades is less than perfect, and disagreements have the potential to change management in a substantial number of pediatric patients.

  1. Inter-radiologist agreement for CT scoring of pediatric splenic injuries and effect on an established clinical practice guideline

    International Nuclear Information System (INIS)

    Leschied, Jessica R.; Smith, Ethan A.; Ladino-Torres, Maria F.; Dillman, Jonathan R.; Mazza, Michael B.; Chong, Suzanne T.; Hoff, Carrie N.; Davenport, Matthew S.; Khalatbari, Shokoufeh; Ehrlich, Peter F.

    2016-01-01

    The American Pediatric Surgical Association (APSA) advocates for the use of a clinical practice guideline to direct management of hemodynamically stable pediatric spleen injuries. The clinical practice guideline is based on the CT score of the spleen injury according to the American Association for the Surgery of Trauma (AAST) CT scoring system. To determine the potential effect of radiologist agreement for CT scoring of pediatric spleen injuries on an established APSA clinical practice guideline. We retrospectively analyzed blunt splenic injuries occurring in children from January 2007 to January 2012 at a single level 1 trauma center (n = 90). Abdominal CT exams performed at clinical presentation were reviewed by four radiologists who documented the following: (1) splenic injury grade (AAST system), (2) arterial extravasation and (3) pseudoaneurysm. Inter-rater agreement for AAST injury grade was assessed using the multi-rater Fleiss kappa and Kendall coefficient of concordance. Inter-rater agreement was assessed using weighted (AAST injury grade) or prevalence-adjusted bias-adjusted (binary measures) kappa statistics; 95% confidence intervals were calculated. We evaluated the hypothetical effect of radiologist disagreement on an established APSA clinical practice guideline. Inter-rater agreement was good for absolute AAST injury grade (kappa: 0.64 [0.59-0.69]) and excellent for relative AAST injury grade (Kendall w: 0.90). All radiologists agreed on the AAST grade in 52% of cases. Based on an established clinical practice guideline, radiologist disagreement could have changed the decision for intensive care management in 11% (10/90) of children, changed the length of hospital stay in 44% (40/90), and changed the time to return to normal activity in 44% (40/90). Radiologist agreement when assigning splenic AAST injury grades is less than perfect, and disagreements have the potential to change management in a substantial number of pediatric patients. (orig.)

  2. Inter-radiologist agreement for CT scoring of pediatric splenic injuries and effect on an established clinical practice guideline

    Energy Technology Data Exchange (ETDEWEB)

    Leschied, Jessica R.; Smith, Ethan A.; Ladino-Torres, Maria F.; Dillman, Jonathan R. [University of Michigan Health System, Department of Radiology, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Mazza, Michael B.; Chong, Suzanne T.; Hoff, Carrie N. [University of Michigan Health System, Department of Radiology, Division of Emergency Radiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Davenport, Matthew S. [University of Michigan Health System, Department of Radiology, Division of Abdominal Imaging, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Khalatbari, Shokoufeh [University of Michigan, Michigan Institute for Clinical and Health Research, Ann Arbor, MI (United States); Ehrlich, Peter F. [University of Michigan Health System, Department of Surgery, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States)

    2016-02-15

    The American Pediatric Surgical Association (APSA) advocates for the use of a clinical practice guideline to direct management of hemodynamically stable pediatric spleen injuries. The clinical practice guideline is based on the CT score of the spleen injury according to the American Association for the Surgery of Trauma (AAST) CT scoring system. To determine the potential effect of radiologist agreement for CT scoring of pediatric spleen injuries on an established APSA clinical practice guideline. We retrospectively analyzed blunt splenic injuries occurring in children from January 2007 to January 2012 at a single level 1 trauma center (n = 90). Abdominal CT exams performed at clinical presentation were reviewed by four radiologists who documented the following: (1) splenic injury grade (AAST system), (2) arterial extravasation and (3) pseudoaneurysm. Inter-rater agreement for AAST injury grade was assessed using the multi-rater Fleiss kappa and Kendall coefficient of concordance. Inter-rater agreement was assessed using weighted (AAST injury grade) or prevalence-adjusted bias-adjusted (binary measures) kappa statistics; 95% confidence intervals were calculated. We evaluated the hypothetical effect of radiologist disagreement on an established APSA clinical practice guideline. Inter-rater agreement was good for absolute AAST injury grade (kappa: 0.64 [0.59-0.69]) and excellent for relative AAST injury grade (Kendall w: 0.90). All radiologists agreed on the AAST grade in 52% of cases. Based on an established clinical practice guideline, radiologist disagreement could have changed the decision for intensive care management in 11% (10/90) of children, changed the length of hospital stay in 44% (40/90), and changed the time to return to normal activity in 44% (40/90). Radiologist agreement when assigning splenic AAST injury grades is less than perfect, and disagreements have the potential to change management in a substantial number of pediatric patients. (orig.)

  3. Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Johnson, Thorsten R.C.; Sommer, Wieland H.; Thierfelder, Kolja M.; Meinel, Felix G. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-06-01

    To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDI{sub vol}, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. (orig.)

  4. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  5. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  6. Intraparenchymal hemorrhage segmentation from clinical head CT of patients with traumatic brain injury

    Science.gov (United States)

    Roy, Snehashis; Wilkes, Sean; Diaz-Arrastia, Ramon; Butman, John A.; Pham, Dzung L.

    2015-03-01

    Quantification of hemorrhages in head computed tomography (CT) images from patients with traumatic brain injury (TBI) has potential applications in monitoring disease progression and better understanding of the patho-physiology of TBI. Although manual segmentations can provide accurate measures of hemorrhages, the processing time and inter-rater variability make it infeasible for large studies. In this paper, we propose a fully automatic novel pipeline for segmenting intraparenchymal hemorrhages (IPH) from clinical head CT images. Unlike previous methods of model based segmentation or active contour techniques, we rely on relevant and matching examples from already segmented images by trained raters. The CT images are first skull-stripped. Then example patches from an "atlas" CT and its manual segmentation are used to learn a two-class sparse dictionary for hemorrhage and normal tissue. Next, for a given "subject" CT, a subject patch is modeled as a sparse convex combination of a few atlas patches from the dictionary. The same convex combination is applied to the atlas segmentation patches to generate a membership for the hemorrhages at each voxel. Hemorrhages are segmented from 25 subjects with various degrees of TBI. Results are compared with segmentations obtained from an expert rater. A median Dice coefficient of 0.85 between automated and manual segmentations is achieved. A linear fit between automated and manual volumes show a slope of 1.0047, indicating a negligible bias in volume estimation.

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  10. Role of carbon-11 choline PET/CT in the management of uterine carcinoma. Initial experience

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Sawada, Morio; Arai, Yasuaki; Tateishi, Ukihide; Inoue, Tomio; Maeda, Tetsuo; Sugimura, Kazuro; Terauchi, Takashi; Kano, Daisuke

    2009-01-01

    The present study was conducted to clarify the role of carbon-11 choline ( 11 C-choline) positron emission tomography (PET)/computed tomography (CT) in the management of uterine carcinoma. Twenty-two patients who underwent 11 C-choline PET/CT and pelvic MRI were evaluated retrospectively. The images were reviewed by a board-certified radiologist and a nuclear medicine specialist who were unaware of any clinical information, and a consensus was reached. Diagnostic accuracy of PET/CT was evaluated for staging. The reference standard consisted of histological examination (n=17) and follow-up conventional CT (n=5). In five patients with cervical carcinoma, 11 C-choline PET/CT was performed before and after treatment that consisted of cisplatin infusion and subsequent radiotherapy. Standardized uptake value (SUV) was compared with unidimensional and volumetric measurements that were made on magnetic resonance images (MRI) before and after treatment. Based on PET/CT interpretations, the reviewers correctly classified tumor (T) stage in 8 patients (47%), nodes (N) stage in 21 patients (96%), metastasis (M) stage in 20 patients (91%), and tumor, nodes and metastasis (TNM) stage in 15 patients (88%). Tumor size, volume, and SUV decreased after treatment in five patients with cervical carcinoma. Using the Pearson correlation test, a significant correlation was found between the reduction rate of SUV and reduction rate of tumor volume. 11 C-choline PET/CT is an accurate means for the management of patients with uterine carcinoma. The combination of 11 C-choline PET/CT and MRI increases the accuracy of staging in patients with uterine carcinoma. (author)

  11. Clinical and CT imaging features of abdominal fat necrosis

    International Nuclear Information System (INIS)

    Zhao Jinkun; Bai Renju

    2013-01-01

    Fat necrosis is a common pathological change at abdominal cross-sectional imaging, and it may cause abdominal pain, mimic pathological change of acute abdomen, or be asymptomatic and accompany other pathophysiologic processes. Fat necrosis is actually the result of steatosis by metabolism or mechanical injury. Common processes that are present in fat necrosis include epiploic appendagitis, infarction of the greater omentum, pancreatitis, and fat necrosis related to trauma or ischemia. As a common fat disease, fat necrosis should be known by clinicians and radiologists. Main content of this text is the clinical symptoms and CT findings of belly fat necrosis and related diseases. (authors)

  12. Outcome prediction in mild traumatic brain injury: age and clinical variables are stronger predictors than CT abnormalities.

    NARCIS (Netherlands)

    Jacobs, B.; Beems, T.; Stulemeijer, M.; Vugt, A.B. van; Vliet, A.M. van der; Borm, G.F.; Vos, P.E.

    2010-01-01

    Mild traumatic brain injury (mTBI) is a common heterogeneous neurological disorder with a wide range of possible clinical outcomes. Accurate prediction of outcome is desirable for optimal treatment. This study aimed both to identify the demographic, clinical, and computed tomographic (CT)

  13. Model-based PSF and MTF estimation and validation from skeletal clinical CT images.

    Science.gov (United States)

    Pakdel, Amirreza; Mainprize, James G; Robert, Normand; Fialkov, Jeffery; Whyne, Cari M

    2014-01-01

    A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

  14. Model-based PSF and MTF estimation and validation from skeletal clinical CT images

    International Nuclear Information System (INIS)

    Pakdel, Amirreza; Mainprize, James G.; Robert, Normand; Fialkov, Jeffery; Whyne, Cari M.

    2014-01-01

    Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the

  15. Model-based PSF and MTF estimation and validation from skeletal clinical CT images

    Energy Technology Data Exchange (ETDEWEB)

    Pakdel, Amirreza [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3M2 (Canada); Mainprize, James G.; Robert, Normand [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada); Fialkov, Jeffery [Division of Plastic Surgery, Sunnybrook Health Sciences Center, Toronto, Ontario M4N 3M5, Canada and Department of Surgery, University of Toronto, Toronto, Ontario M5S 3M2 (Canada); Whyne, Cari M., E-mail: cari.whyne@sunnybrook.ca [Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada and Department of Surgery, Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3M2 (Canada)

    2014-01-15

    Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge

  16. WE-G-209-02: CT

    International Nuclear Information System (INIS)

    Kofler, J.

    2016-01-01

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  17. WE-G-209-02: CT

    Energy Technology Data Exchange (ETDEWEB)

    Kofler, J. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  18. Recurrent bladder carcinoma: clinical and prognostic role of 18 F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Alongi, Pierpaolo [San Raffaele G. Giglio Institute, Department of Radiological Sciences, Nuclear Medicine Unit, Cefalu (Italy); Caobelli, Federico [Basel University Hospital, Department of Nuclear Medicine, Basel (Switzerland); Gentile, Roberta; Baldari, Sergio [University of Messina, Nuclear Medicine Unit, Department of Biomedical Sciences and Morphological and Functional Images, Messina (Italy); Stefano, Alessandro; Russo, Giorgio; Gilardi, Maria Carla [IBFM-CNR, Cefalu (Italy); Albano, Domenico [Universita degli Studi di Palermo, DIBIMEF - Sezione di Scienze Radiologiche, Palermo (Italy); Midiri, Massimo [San Raffaele G. Giglio Institute, Department of Radiological Sciences, Nuclear Medicine Unit, Cefalu (Italy); Universita degli Studi di Palermo, DIBIMEF - Sezione di Scienze Radiologiche, Palermo (Italy)

    2017-02-15

    A small number of studies evaluated the detection rate of lesions from bladder carcinoma (BC) of 18 F-FDG PET/CT in the restaging process. However, the prognostic role of FDG PET/CT still remains unclear. The aim of the present study was to evaluate the accuracy, the effect upon treatment decision, and the prognostic value of FDG PET/CT in patients with suspected recurrent BC. Forty-one patients affected by BC underwent FDG PET/CT for restaging purpose. The diagnostic accuracy of visually interpreted FDG PET/CT was assessed compared to histology (n = 8), other diagnostic imaging modalities (contrast-enhanced CT in 38/41 patients and MRI in 15/41) and clinical follow-up (n = 41). Semiquantitative PET values (SUVmax, SUVmean, SUL, MTV, TLG) were calculated using a graph-based method. Progression-free survival (PFS) and overall survival (OS) were assessed by using Kaplan-Meier curves. The risk of progression (hazard ratio, HR) was computed by Cox regression analysis by considering all the available variables. PET was considered positive in 21 of 41 patients. Of these, recurrent BC was confirmed in 20 (95 %). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FDG PET/CT were 87 %, 94 %, 95 %, 85 %, 90 %. AUC was 0.9 (95 %IC 0.8-1). Bayesian positive and negative likelihood ratios were 14.5 and 0.13, respectively. FDG PET/CT findings modified the therapeutic approach in 16 patients (modified therapy in 10 PET-positive patients, watch-and-wait in six PET-negative patients). PFS was significantly longer in patients with negative scan vs. those with pathological findings (85 % vs. 24 %, p < 0.05; HR = 12.4; p = 0.001). Moreover, an unremarkable study was associated with a longer OS (88 % vs. 47 % after 2 years and 87 % vs. 25 % after 3 years, respectively, p < 0.05). Standardized uptake value (SUV)max > 6 and total lesion glycolysis (TLG) > 8.5 were recognized as the most accurate thresholds to predict PFS (2-year PFS 62 % for

  19. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  20. Pulmonary nodules and masses in lung transplant recipients: clinical and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Morla, Olivier; Liberge, Renan; Arrigoni, Pierre Paul; Frampas, Eric [Service de Radiologie Centrale, C.H.U. Hotel Dieu, Nantes (France)

    2014-09-15

    The purpose of this study was to review the clinical and CT findings of pulmonary nodules and masses in lung transplant recipients and to determine distinguishing features among the various aetiologies. This retrospective study included 106 lung transplant recipients who had a chest CT performed over a 7-year period in a single institution. Twenty-four cases of pulmonary nodules and masses were observed on CT. Among the single lesions, three (50 %) were due to infections, one (17 %) to organizing pneumonia, and two (33 %) remained of undetermined origin. Among the multiple lesions, 14 (78 %) were due to infection, three to post-transplant lymphoproliferative disorder (17 %), and one to bronchogenic carcinoma (5 %). The two main microorganisms were P. aeruginosa and Aspergillus spp. Among 12 solid nodules > 1 cm, four (33 %) were due to malignancy: three post-transplant lymphoproliferative disorders (25 %), and one bronchogenic carcinoma (8 %). Among five cavitary nodules four (80 %) were due to aspergillosis. Infection is the most frequent aetiology of pulmonary nodules and masses in lung transplant recipients, but other causes such as post-transplant lymphoproliferative disorder, bronchogenic carcinoma, or organizing pneumonia should be considered. (orig.)

  1. The role of 68Ga-DOTA-NOC PET/CT in evaluating neuroendocrine tumors: real-world experience from two large neuroendocrine tumor centers.

    Science.gov (United States)

    Haidar, Mohamad; Shamseddine, Ali; Panagiotidis, Emmanouil; Jreige, Mario; Mukherji, Deborah; Assi, Rita; Abousaid, Rayan; Ibrahim, Toni; Haddad, Marwan M; Vinjamuri, Sobhan

    2017-02-01

    Our aim was to assess the role of Ga-DOTA-NOC PET/CT as a tool for the management of neuroendocrine tumors (NETs), evaluating the clinical impact on patients from two large NET centers in different geopolitical settings. This is a retrospective study of patients with NETs who underwent Ga-DOTA-NOC PET/CT at Royal Liverpool University Hospital (UK) and at Mount Lebanon Hospital (Lebanon). Indications for imaging and findings of the PET/CT along with demographic and clinical outcome data were recorded and evaluated. Four hundred and forty-five patients fulfilled the inclusion criteria, with a median age at the time of diagnosis of 56 (range: 3-90) years; 248 (55.7%) patients were male.Ga-DOTA-NOC PET/CT was indicated for staging in 193 (43.4%) patients, for diagnosis in 124 (27.9%) patients, for follow-up in 97 (21.7%) patients, and for identification of a primary NET site in 31 (7%) patients.One hundred and four (27.9%) patients underwent Ga-DOTA-NOC PET/CT for the primary diagnosis of NET, of whom 66 (52.7%) patients presented with a clinical suspicion of NET, 10 (8.3%) patients presented with a biochemical suspicion of NET only, and 48 (38.8%) patients presented with a suspicious NET lesion discovered on another imaging modality. The most common clinical presentation was typical carcinoid syndrome [4 (33%) patients].Results on the basis of histology were used as the gold standard for the diagnosis in 57% of patients and the remaining on the basis of follow-up as per established clinical consensus. Sensitivity, specificity, negative-predictive value, and positive-predictive value of PET/CT were 87.1, 97.7, 79.6, and 98.7%, respectively, for the entire sample. Accuracy was measured using the receiver operating characteristic curve analysis with an area under the curve of 0.924 (95% confidence interval: 0.874-0.974). Ga-DOTA-NOC PET/CT is a highly sensitive and specific study for the diagnosis and follow-up of patients with neuroendocrine tumors. These results

  2. A clinical study of acute cerebral infarction with a midline shift on the CT scan

    International Nuclear Information System (INIS)

    Takemae, Toshiki; Mizukami, Masahiro; Kin, Hiroshi; Kawase, Takeshi; Araki, Goro

    1978-01-01

    Twenty-one cases of acute cerebral infarction with a midline shift on the CT scan were studied with respect to the development of the midline shift, the angiographic findings, the clinical pictures and the outcome of these patients. The CT findings of hemorrhagic infarction were also studied. No cases showed a midline shift on a CT scan taken within 6 hours after the onset. A midline shift was, however, noted as early as 9 hours after the onset, and it reached its peak between the 2nd and 7th day of the onset. It gradually disappeared by the end of the third week. Hemorrhagic infarction was diagnosed in 6 patients by either spinal tap or autopsy. The CT findings of these hemorrhagic infarction were divided into two types, solid hemorrhages with an unequivocal high density within the low-density area, and small, scattered hemorrhagic of almost the same density as normal brain tissue within the low-density area. In 19 of 21 patients, an round-edged occlusion and/or embolus were observed on the initial angiograms. The recanalization of the occluded vessels was proved in 10 of 14 patients by subsequent angiographic studies. Twenty of 21 patients showed a sudden development of neurological symptoms, and 15 patients had a history of various kinds of heart disease, such as atrial fibrillation, valvular heart disease and myocardial infarction. The patients had atrial fibrillation on EKG on admission. These angiographic findings and clinical pictures strongly suggest that the infarction with a midline shift on the CT scan may be caused by a cerebral embolism of cardiac origin. Eight patients died of cerebral herniation between the 2nd and 6th day of the onset. Taking these poor outcomes into consideration, surgical as well as medical decompression of the brain would seem to be most important when the CT scan shows a midline shift. (author)

  3. Assessing the prevalence and clinical relevance of positive abdominal and pelvic CT findings in senior patients presenting to the emergency department.

    Science.gov (United States)

    Alabousi, Abdullah; Patlas, Michael N; Meshki, Malek; Monteiro, Sandra; Katz, Douglas S

    2016-04-01

    The purpose of our study was to retrospectively evaluate the prevalence and clinical relevance of positive abdominal and pelvic CT findings for patients 65 years of age and older, when compared with all other scanned adult Emergency Department (ED) patients, at a single tertiary care hospital. Our hypothesis was that there is an increased prevalence and clinical relevance of positive abdominal/pelvic CT findings in senior patients. A research ethics board-approved retrospective review of all adult patients who underwent an emergency CT of the abdomen and pelvis for acute nontraumatic abdominal and/or pelvic signs and symptoms was performed. Two thousand one hundred two patients between October 1, 2011, and September 30, 2013, were reviewed. Six hundred thirty-one patients were included in the 65 group (209 men and 253 women; mean age 77.6, age range 65-99). Overall, there were more positive CT findings for patients 65 group (257 positive cases, 55.6 %), which was a statistically significant difference (p 65 group, there were no statistically significant differences in the clinical/surgical relevance of the positive CT findings between the two groups. The findings of our retrospective study therefore refute our hypothesis that there is an increased prevalence of positive abdominal CT findings in patients >65. This may be related to ED physicians at our institution being more hesitant to order CT examinations for the younger population, presumably due to radiation concerns. However, older patients in our series were more likely to present with complicated appendicitis, and a lower threshold for ordering CT examinations of the abdomen and pelvis in this patient population should therefore be considered.

  4. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  5. Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings

    International Nuclear Information System (INIS)

    Salzano, A.; Nocera, V.; De Rosa, A.; Vigliotti, A.; Rossi, E.; Carbone, M.; Gatta, G.

    2000-01-01

    Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the mid-chest for accurate assessment of diaphragm and lung bases and to exclude associated pleuropulmonary damage. Penetrating liver wounds were caused by firearms in 70% of cases, by stabbing in 12% and, in the extant 18%, by other cases such as home accidents, road and work traumas, and liver biopsy. In this series, the liver was most frequently involved, especially by firearms wounds; in the 16 cases the most frequent injuries were hemorrhagic tears. It was found bullets in the liver in 6 cases. In one case of home accident the patient wounded himself while slicing bread with a long knife, which cut into the anterior abdominal wall and tore the anterior liver capsule, as seen at CTA. Penetrating wounds to liver and abdomen are less frequent than those to the chest. In the past decade the use of CT has changed the diagnostic and therapeutic approach to such injuries completely, decreasing the resort to explorative laparotomy and hepatorrhaphy. Indeed, CT provides a clear picture of

  6. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  7. Feasibility of simultaneous PET/MR of the carotid artery: first clinical experience and comparison to PET/CT

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Knudsen, Andreas; Hag, Anne Mette Fisker

    2013-01-01

    The study aimed at comparing PET/MR to PET/CT for imaging the carotid arteries in patients with known increased risk of atherosclerosis. Six HIV-positive men underwent sequential PET/MR and PET/CT of the carotid arteries after injection of 400 MBq of 18F-FDG. PET/MR was performed a median of 131......) indicating that the luminal 18F-FDG content had minimal influence on the values. The study shows for the first time that simultaneous PET/MR of the carotid arteries is feasible in patients with increased risk of atherosclerosis. Quantification of 18F-FDG uptake correlated well between PET/MR and PET...

  8. CT urography of urinary diversions with enhanced CT digital radiography: preliminary experience.

    Science.gov (United States)

    Sudakoff, Gary S; Guralnick, Michael; Langenstroer, Peter; Foley, W Dennis; Cihlar, Krista L; Shakespear, Jonathan S; See, William A

    2005-01-01

    The purpose of this study was to determine if 3D-rendered CT urography (CTU) depicts both normal and abnormal findings in patients with urinary diversions and if the addition of contrast-enhanced CT digital radiography (CTDR) improves opacification of the urinary collecting system. Thirty CTU and contrast-enhanced CTDR examinations were performed in 24 patients who underwent cystectomy for bladder cancer. Indications for evaluation included hematuria, tumor surveillance, or suspected diversion malfunction. All examinations were evaluated without knowledge of the stage or grade of a patient's tumor and were compared with the clinical records. Opacification of the urinary collecting system was evaluated with 3D CTU alone, contrast-enhanced CTDR alone, and combined CTU and CTDR. Nine abnormalities were identified including distal ureteral strictures (n = 4), vascular compression of the mid left ureter (n = 1), scarring of the mid right pole infundibulum (n = 1), bilateral hydronephrosis and hydroureter (n = 1), urinary reservoir calculus (n = 1), and tumor recurrence invading the afferent limb of the neobladder (n = 1). Eight of the nine detected abnormalities were surgically or pathologically confirmed. All abnormalities were identified on all three imaging techniques but were best seen on 3D CTU and enhanced CTDR images. Incomplete opacification of the urinary collecting system occurred in 17 patients with CTU alone, 12 patients with contrast-enhanced CTDR alone, and nine patients with combined CTU and contrast-enhanced CTDR. Compared with CTU alone, the combined technique of 3D CTU and contrast-enhanced CTDR improved opacification by a statistically significant difference (p = 0.037). CTU with 3D rendering can accurately depict both normal and abnormal postoperative findings in patients with urinary diversions. Adding enhanced CTDR can improve visualization of the urinary collecting system.

  9. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  10. The clinical application of PET/CT: a contemporary review

    International Nuclear Information System (INIS)

    Brady, Z.; Partridge, M.; Trapp, J.V.

    2008-01-01

    Full text: The combination of positron emission tomography (PET) scanners and x-ray computed tomography (CT) scanners into a single PET CT scanner has resulted in significant improvements in the diagnosis and staging of disease, particularly in the field of oncology. A decade on from the publication of the details of the first PET/CT scanner, we review the technology and applications of the modality. We examine the design aspects of combining two different imaging types into a single scanner, and the artefacts produced such as attenuation correction, motion and CT truncation artefacts. The article also provides a discussion and literature review of the applications of PET/CT to date, covering detection of tumours, radiotherapy treatment planning, patient management, and applications external to the field of oncology.

  11. Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer

    International Nuclear Information System (INIS)

    Kim, Byung Il

    2008-01-01

    In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone

  12. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  13. Correlation of CT and MR findings with clinical outcome

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Kim, In One; Choi, Du Hwan; Yeon, Kyung Mo; Hwang, Yong Seung

    1991-01-01

    A retrospective analysis of the CT and MR findings of 14 pediatric patients with brain stem tumors was performed to evaluate whether the clinical outcome could be predicted from a radiographic pattern of the tumors. CT was performed in 11 patients and MR was performed in 14 patients. Ten patients were treated with radiation therapy (RT) alone, 2 patients with RT and chemotherapy, and 2 patients underwent subtotal resection. After treatment, 9 patients died within 10 months, and 5 patients were alive for 9 months to 51 months. There was no statistically significant correlation between survival and tumor location or size, but in 2 cases of exophytic growing tumor, a subtotal resection of the tumor was possible and the patients were alive for 9 months and 24 months, respectively. The tumors with a cystic portion and definite rim enhancement revealed a poor response to conventional RT, and all 6 patients died within 10 months. In conclusion, a better prognosis is predicted in the case of an exophytic growing tumor after surgical resection, but the definite ring-enhancing tumor showed a poor response on conventional RT. Also, we should consider a more active therapeutic approach such as hyperfractionated RT or combinations of chemotherapy to improve the prognosis

  14. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Poul Henning [Vejle Hospital, Department of Medicine, Division of Respiratory Medicine, Vejle (Denmark); Holdgaard, Paw Christian [Vejle Hospital, Department of Nuclear Medicine, Vejle (Denmark); Christensen, Janne Buck [Odense University Hospital/University of Southern Denmark, Department of Quality and Research/HTA, Odense University Hospital and Medical Research Library, Odense (Denmark); Hoeilund-Carlsen, Poul Flemming [Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark)

    2016-10-15

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: (1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). (2) PET-CT reduces the number of futile treatment trials (recommendation level A). (3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). (1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (<1 cm) and non-solid, solitary pulmonary nodules. These abnormalities should be followed up by CT in a structured programme. (2) No curative-intent treatment should be commenced until a PET-CT scan has excluded occult distant metastases. (3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out. (orig.)

  15. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    International Nuclear Information System (INIS)

    Madsen, Poul Henning; Holdgaard, Paw Christian; Christensen, Janne Buck; Hoeilund-Carlsen, Poul Flemming

    2016-01-01

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: (1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). (2) PET-CT reduces the number of futile treatment trials (recommendation level A). (3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). (1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (<1 cm) and non-solid, solitary pulmonary nodules. These abnormalities should be followed up by CT in a structured programme. (2) No curative-intent treatment should be commenced until a PET-CT scan has excluded occult distant metastases. (3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out. (orig.)

  16. Giant Serous Cystadenoma of the Pancreas (⩾10 cm: The Clinical Features and CT Findings

    Directory of Open Access Journals (Sweden)

    Qing-Yu Liu

    2016-01-01

    Full Text Available Purpose. To report the clinical features and CT manifestations of giant pancreatic serous cystadenoma (≥10 cm. Methods. We retrospectively reviewed the clinical features and CT findings of 6 cases of this entity. Results. All 6 patients were symptomatic. The tumors were 10.2 cm–16.5 cm (median value, 13.0 cm. CT imaging revealed that all 6 cases showed microcystic appearances (n=5 or mixed microcystic and macrocystic appearances (n=1. Five patients with tumors at the distal end of the pancreas received distal pancreatectomy. Among these 5 patients, 2 patients underwent partial transverse colon resection or omentum resection due to close adhesion. One patient whose tumor was located in the pancreatic head underwent pancreaticoduodenectomy; however, due to encasement of the portal and superior mesenteric veins, the tumor was incompletely resected. One patient had abundant draining veins on the tumor surface and suffered large blood loss (700 mL. After 6–49 months of follow-up the 6 patients showed no tumor recurrence or signs of malignant transformation. Conclusions. Giant pancreatic serous cystadenoma necessitates surgical resection due to large size, symptoms, uncertain diagnosis, and adjacent organ compression. The relationship between the tumors and the neighboring organs needs to be carefully assessed before operation on CT image.

  17. Pulmonary involvement in Churg-Strauss syndrome: an analysis of CT, clinical, and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung; Lee, Kyung Soo; Chong, Semin; Chung, Myung Jin; Yi, Chin A; Kim, Ha Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Seoul (Korea); Chung, Man Pyo [Samsung Medical Center, Sungkyunkwan University School of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Medicine, Seoul (Korea); Han, Joungho [Samsung Medical Center, Sungkyunkwan University School of Medicine, Department of Pathology, Seoul (Korea)

    2007-12-15

    We tried to assess retrospectively thin-section CT findings of Churg-Strauss syndrome (CSS) in 25 patients and to compare these findings with clinical and histopathologic findings. Of 25 patients, 19 (76%) had parenchymal abnormalities at CT; small nodules (n = 12; 63%), ground-glass opacity (n = 10; 53%), bronchial wall thickening (n = 10; 53%), and consolidation (n = 8; 42%). Parenchymal abnormalities (n = 19) were categorizable as an airway pattern in 11 and an airspace pattern in eight. Patients with an airway pattern (n = 5) had obstructive (n = 3) or combined (n = 2) PFT results, whereas those with an airspace pattern (n = 4) had restrictive (n = 3) or obstructive (n = 1) results. Parenchymal opacities at CT corresponded histologically to areas of eosinophilic pneumonia, necrotizing granulomas, and granulomatous vasculitis; small nodules to eosinophilic bronchiolitis and peribronchiolar vasculitis; and bronchial wall thickening to airway wall eosinophil and lymphocyte infiltration. Patients with airspace pattern responded more readily to treatment than those with airway pattern. CT shows lung parenchymal abnormalities in about three-quarters of CSS patients and these abnormalities can be categorized as airspace or airway patterns. This classification helps predict PFT data, underlying histopathology, and treatment response. (orig.)

  18. Pulmonary involvement in Churg-Strauss syndrome: an analysis of CT, clinical, and pathologic findings

    International Nuclear Information System (INIS)

    Kim, Yoon Kyung; Lee, Kyung Soo; Chong, Semin; Chung, Myung Jin; Yi, Chin A.; Kim, Ha Young; Chung, Man Pyo; Han, Joungho

    2007-01-01

    We tried to assess retrospectively thin-section CT findings of Churg-Strauss syndrome (CSS) in 25 patients and to compare these findings with clinical and histopathologic findings. Of 25 patients, 19 (76%) had parenchymal abnormalities at CT; small nodules (n = 12; 63%), ground-glass opacity (n = 10; 53%), bronchial wall thickening (n = 10; 53%), and consolidation (n = 8; 42%). Parenchymal abnormalities (n = 19) were categorizable as an airway pattern in 11 and an airspace pattern in eight. Patients with an airway pattern (n = 5) had obstructive (n = 3) or combined (n = 2) PFT results, whereas those with an airspace pattern (n = 4) had restrictive (n = 3) or obstructive (n = 1) results. Parenchymal opacities at CT corresponded histologically to areas of eosinophilic pneumonia, necrotizing granulomas, and granulomatous vasculitis; small nodules to eosinophilic bronchiolitis and peribronchiolar vasculitis; and bronchial wall thickening to airway wall eosinophil and lymphocyte infiltration. Patients with airspace pattern responded more readily to treatment than those with airway pattern. CT shows lung parenchymal abnormalities in about three-quarters of CSS patients and these abnormalities can be categorized as airspace or airway patterns. This classification helps predict PFT data, underlying histopathology, and treatment response. (orig.)

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  2. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer.

    Science.gov (United States)

    Madsen, Poul Henning; Holdgaard, Paw Christian; Christensen, Janne Buck; Høilund-Carlsen, Poul Flemming

    2016-10-01

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: 1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). 2) PET-CT reduces the number of futile treatment trials (recommendation level A). 3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). ᅟ 1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (PET-CT scan has excluded occult distant metastases. 3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out.

  3. Feasibility of [18F]FDG-PET and coregistered CT on clinical target volume definition of advanced non-small cell lung cancer

    International Nuclear Information System (INIS)

    Messa, C.; IBFM-CNR, Milan; Scientific Institute H.S. Raffaele, Milan; Ceresoli, G.L.; Gregorc, V.; Rizzo, G.; Scientific Institute H.S. Raffaele, Milan; Artioli, D.; Cattaneo, M.; Castellone, P.; Picchio, M.; Landoni, C.; Scientific Institute H.S. Raffaele, Milan; Fazio, F.; IBFM-CNR, Milan; Scientific Institute H.S. Raffaele, Milan; Scientific Institute H.S. Raffaele, Milan

    2005-01-01

    Aim. To prospectively evaluate the impact of co registered positron emission tomography (PET) and computed tomography (CT) in 3D conformal radiotherapy (3D-CRT) planning in patients with non-small lung cancer (NSCLC). Methods. Twenty-one patients (median age: 57 years; range: 42-80 years) referred to 3D-CRT for NSCLC were recruited. Positron emission tomography with 18 F-fluorodeoxyglucose ([ 18 F]FDG-PET) and conventional CT images were coregistered (PET/CT images) using a commerciaI software package based on surface matching technique. Neoplastic areas were contoured on [ 18 F]FDGPET images with the aid of the correspondent CT image by a nuclear medicine physician. CT images and their relative PET contours were then transferred to treatment planning system. A radiation oncologist firstly contoured clinical target volumes (CTV) on CT scan alone (CTV-CT), and then on co registered PET/CT images (CTV-PET/CT). CTV-CT and CTV-PET/CT were compared for each patient; a difference higher than 25% was considered of clinical relevance. Results. Three patients were shifted to palliative radiotherapy for metastatic disease or very large tumor size, showed by [ 18 F]FDG-PET. Of the remaining 18 patients a CTV change, after inclusion of PET/CT data, was observed in 10/18 cases (55%): larger in 7/18 (range 33-279%) and smaller in 3/18 patients (range 26-34%), mainly due to inclusion or exclusion of Iymph-nodal disease and to better definition of tumor extent. CTV changes smaller than 25% occurred in the remaining 8/18 patients. Conclusion. [ 18 F]FDG-PET and CT images co-registration in radiotherapy treatment planning Ied to a change in CTV definition in the majority of our patients, which may signillcantly modify management and radiation treatment modality in these patients

  4. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Divya Ratan [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Yash [Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Ashish [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Fang, Kenith [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Cardiothoracic Surgery, Banner University Medical Center, Phoenix, AZ (United States); Gellert, George [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Anesthesiology, Banner University Medical Center, Phoenix, AZ (United States); Morris, Michael F., E-mail: mfmorris@mail.arizona.edu [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States)

    2016-12-15

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low (<40 cases), intermediate (40–75 cases), and high-volume sites (>75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had

  5. Dual energy CT: New horizon in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Goo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  6. Dual-Energy CT: New Horizon in Medical Imaging.

    Science.gov (United States)

    Goo, Hyun Woo; Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  7. A clinical study on the usefulness of CT and MRI imaging in evaluating differential diagnosis and the degree of dementia in vascular dementia

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Mariko [Nippon Medical School, Tokyo (Japan)

    1990-06-01

    In a retrospective review of 117 computed tomography (CT) scans and 56 magnetic resonance imaging (MRI) scans sequentially performed for dementia patients, CT and MRI were compared for assessment of the usefulness in the differential diagnosis and determination of the functional prognosis of vascular dementia. The correlation between CT findings and the degree of mental function was also examined. Since MRI had a higher sensitivity than CT in detecting small infarcts or lacunaes in the perforating area or white matter, it should differentiate vascular dementia from dementia of Alzheimer type. When both dementia of Alzheimer type was clinically diagnosed and infarct areas were detected on either CT or MRI, activity of daily living tended to be poor. Even when mixed type of dementia or vascular dementia was clinically diagnosed in spite of negative findings on either CT or MRI, troublesome behavior was frequently observed, posing the likelihood of dementia of Alzheimer type. The ability of CT and MRI to detect lesions was not correlated with the degree of dementia or aging, even if MRI was capable of detecting smaller lesions. CT was thus considered to be more specific modality for evaluating mental function. The size of lesions on CT was found to be more significant than the number and localization of lesions in determining the degree of dementia in the chronic stage of cerebrovascular disease. The ability of MRI to detect smaller lesions, as well as clinically determined ischemic scores, may assist in the diagnostic differentiation. Lesion size on CT may be an important factor for determining the degree of dementia and functional prognosis. (N.K.).

  8. A clinical study on the usefulness of CT and MRI imaging in evaluating differential diagnosis and the degree of dementia in vascular dementia

    International Nuclear Information System (INIS)

    Hagiwara, Mariko

    1990-01-01

    In a retrospective review of 117 computed tomography (CT) scans and 56 magnetic resonance imaging (MRI) scans sequentially performed for dementia patients, CT and MRI were compared for assessment of the usefulness in the differential diagnosis and determination of the functional prognosis of vascular dementia. The correlation between CT findings and the degree of mental function was also examined. Since MRI had a higher sensitivity than CT in detecting small infarcts or lacunaes in the perforating area or white matter, it should differentiate vascular dementia from dementia of Alzheimer type. When both dementia of Alzheimer type was clinically diagnosed and infarct areas were detected on either CT or MRI, activity of daily living tended to be poor. Even when mixed type of dementia or vascular dementia was clinically diagnosed in spite of negative findings on either CT or MRI, troublesome behavior was frequently observed, posing the likelihood of dementia of Alzheimer type. The ability of CT and MRI to detect lesions was not correlated with the degree of dementia or aging, even if MRI was capable of detecting smaller lesions. CT was thus considered to be more specific modality for evaluating mental function. The size of lesions on CT was found to be more significant than the number and localization of lesions in determining the degree of dementia in the chronic stage of cerebrovascular disease. The ability of MRI to detect smaller lesions, as well as clinically determined ischemic scores, may assist in the diagnostic differentiation. Lesion size on CT may be an important factor for determining the degree of dementia and functional prognosis. (N.K.)

  9. The influence of interpreters' professional background and experience on the interpretation of multimodality imaging of pulmonary lesions using 18F-3'-deoxy-fluorothymidine and 18F-fluorodeoxyglucose PET/CT.

    Directory of Open Access Journals (Sweden)

    Bai-xuan Xu

    Full Text Available OBJECTIVE: Based on the results of a recently accomplished multicenter clinical trial for the incremental value of a dual-tracer (18F-FDG and 18F-FLT, dual-modality (PET and CT imaging in the differential diagnosis of pulmonary lesions, we investigate some issues that might affect the image interpretation and result reporting. METHODS: The images were read in two separate sessions. Firstly the images were read and reported by physician(s of the imaging center on completion of each PET/CT scanning. By the end of MCCT, all images collected during the trial were re-read by a collective of readers in an isolated, blinded, and independent way. RESULTS: One hundred sixty two patients successfully passed the data verification and entered into the final analysis. The primary reporting result showed adding 18F-FDG image information did not change the clinical performance much in sensitivity, specifity and accuracy, but the ratio between SUVFLT and SUVFDG did help the differentiation efficacy among the three subgroups of patients. The collective reviewing result showed the diagnostic achievement varied with reading strategies. ANOVA indicated significant differences among (18F-FDG, (18F-FLT in SUV (F = 14.239, p = 0.004. CT had almost the same diagnostic performance as 18F-FLT. When the 18F-FDG, 18F-FLT and CT images read in pair, both diagnostic sensitivity and specificity improved. The best diagnostic figures were obtained in full-modality strategy, when dual-tracer PET worked in combination with CT. CONCLUSIONS: With certain experience and training both radiologists and nuclear physicians are qualified to read and to achieve the similar diagnostic accuracy in PET/CT study. Making full use of modality combination and selecting right criteria seems more practical than professional back ground and personal experience in the new hybrid imaging technology, at least when novel tracer or application is concerned.

  10. CT colonography after colostomy - clinical application and technical feasibility

    International Nuclear Information System (INIS)

    Nedevska, A.

    2013-01-01

    Full text:Introduction: The aim of this study was to evaluate the clinical application and technical implementation of computed tomographic (CT ) colonoscopy in patients undergoing sigmoid or rectal resection and following sigmoid colostomy in the course of standard diagnostic postoperative follow-up and prior to the reconstructive colon surgery. Materials and Methods: The study included 48 patients who underwent anterior abdomen-perineal or rectal resection and subsequent sigmoid colostomy in case of sigma or rectum carcinoma. The pre-procedure bowel preparation included a full colon cleansing and barium-based fecal tagging. The balloon catheter (18 F) is placed in the colonic stoma. The balloon is insufflated with 15-30 ml saline or air. The balloon was gently pulled until opening of the stoma has been closed completely. In 15 patients, a second catheter was placed in the remaining rectum. Contrast scanning in supination was done for all patients. An additional scanning in left and right lateral position was necessary for 9 patients. Results: All studies were carried out without any major complications. All patients tolerated the intubation and insufflation of air into the intestinal lumen. Two patients (4%) have evaluated the examination as uncomfortable. In 6 patients (12.5 %) it was impossible to evaluate the intestinal segments because due to a collapse of the wall. Five of them were localized in the descending colon. In 5 patients there was a significant amount of residual intestinal contents. The fecal tagging and intravenous contrast enhancing allowed the assessment of these intestinal segments. The rectal residue was correctly assessed in all patients in terms of length, position and wall changes. Conclusion: CT colonoscopy is applicable after sigmostoma in patients with abdomen-perineal and anterior rectal resection. Further in-depth studies are needed to determine the clinical indications and reliability of the method

  11. Ovarian cancer: the clinical role of US, CT, and MRI

    International Nuclear Information System (INIS)

    Togashi, K.

    2003-01-01

    This article presents an overview of ovarian cancer, which addresses the clinical roles of imaging studies, including US, CT, and MR imaging in the course of diagnosis and treatment of this important disease. US is the modality of choice in the evaluation of patients with suspected adnexal masses. Although its accuracy is not sufficient to avert surgery, morphological analysis of adnexal masses with US helps narrow the differential diagnosis, determining the degree of suspicion for malignancy, usually in concert with a serum CA-125 level. Combined morphological and vascular imaging obtained by US appear to further improve the preoperative assessment of adnexal masses. For uncertain or problematic cases, MR imaging helps to distinguish benign from malignant, with an overall accuracy for the diagnosis of malignancy of 93%. The accuracy of MR imaging in the confident diagnosis of mature cystic teratoma, endometrial cysts, and leiomayomas is very high. CT is not indicated for differential diagnosis of adnexal masses because of poor soft tissue discrimination, except for fatty tissue and for calcification, and the disadvantages of irradiation. In the staging of ovarian cancer, CT, US, and MR imaging all have a similarly high accuracy. Although it is difficult to suggest a simple algorithm for evaluating the state of women with adnexal masses, the correct preoperative diagnosis and staging of ovarian cancer with the use of any of these imaging studies will lead to an appropriate referral to a specialist in gynecologic oncology and offer a significant survival advantage for patients with ovarian cancer. (orig.)

  12. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  13. Subprosthetic Pannus after Aortic Valve Replacement Surgery: Cardiac CT Findings and Clinical Features.

    Science.gov (United States)

    Han, Kichang; Yang, Dong Hyun; Shin, So Youn; Kim, Namkug; Kang, Joon-Won; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Lim, Tae-Hwan

    2015-09-01

    To investigate the cardiac computed tomographic (CT) findings and clinical implications of subprosthetic pannus in patients who have undergone aortic valve replacement. The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. From April 2011 to March 2012, 88 patients (mean age, 63 years; 45 men) with a prosthetic aortic valve who underwent cardiac CT were retrospectively selected. Dynamic cardiac CT images were analyzed by using a multiplanar reformatted technique. The presence or absence of subprosthetic pannus and its extent were evaluated at cardiac CT. The geometric orifice area and the effective orifice area of each prosthetic valve were measured to enable analysis of the pannus encroachment ratio in the systolic phase. Hemodynamic parameters at echocardiography, including mean transprosthetic pressure gradient (MTPG), were compared between patients with and those without pannus. The encroachment ratio and the MTPG were correlated by using the Spearman test to evaluate the relationship between the two variables. Seventeen patients (19%) had subprosthetic pannus at cardiac CT. In patients with subprosthetic pannus, MTPG, peak pressure gradient, transvalvular peak velocity, and left ventricular ejection fraction (LVEF) were significantly higher than in patients without pannus (MTPG: 28.1 mm Hg ± 19.8 [standard deviation] vs 14.0 mm Hg ± 6.5, P = .004; peak pressure gradient: 53.1 mm Hg ± 38.4 vs 26.1 mm Hg ± 11.4, P = .004; transvalvular peak velocity: 3.3 m/sec ± 1.3 vs 2.5 m/sec ± 0.5; and LVEF: 64.7% ± 7.4 vs 56.8% ± 10.5, P = .004). A high MTPG (≥40 mm Hg) was observed in four patients at echocardiography, and subprosthetic panni were identified at CT in all four patients. In patients with increased MTPGs, the encroachment ratio by subprosthetic pannus at CT was significantly higher than that in patients with MTPGs of less than 40 mm Hg (42.7 ± 13.3 vs 7.6 ± 3, P = .012

  14. The interventional treatment of acute renal infarction:clinical experience in six cases

    International Nuclear Information System (INIS)

    Wang Kai; Jiang Guomin; Zhao Jinwei; Li Shaoqin; Tian Feng; Huang Wenhua; Zhang Xianshun; Liu Yizhi

    2010-01-01

    Objective: To discuss the clinical characteristics of acute renal infarction and to evaluate the endovascular interventional therapy in treating acute renal infarction. Methods: Since 2006, six patients with acute renal infarction were encountered in our hospital. Renal arterial suction and thrombolytic therapy were immediately carried out as soon as the diagnosis was confirmed. The clinical data were retrospectively analyzed. Results: Based on clinical manifestations, enhanced CT scan and angiography, the diagnosis of acute renal infarction was definitely confirmed in all 6 patients. After renal arterial suction and thrombolytic therapy the clinical symptoms were markedly relieved and the blood flow in infracted area completely or partially returned to normal. Conclusion: The clinical presentation of acute renal infarction is not characteristic. For the diagnosis of acute renal infarction contrast-enhanced CT scanning and renal angiography are the exams of first choice. Renal artery suction and thrombolytic therapy is a safe and effective treatment for acute renal infarction. (authors)

  15. Clinical value of 99Tcm-octreotide SPECT/CT in diagnostics of lung cancer

    International Nuclear Information System (INIS)

    Liu Xiaofang; Li Mei; Liu Yong; Li Ran; Xu Jie; Sun yongchang; Dai Haojie

    2012-01-01

    Objective: To evaluate the clinical value of 99 Tc m -Octreotide SPECT-CT in the diagnosis of lung cancer. Methods: Sixty-five consecutive patients with suspected lung cancer received intravenous injection of 740 MBq 99 Tc m -Octreotide and additional SPECT images of the chest were performed at 4h post injection. The SPECT/CT images were interpreted separately. The tumor uptake of 99 Tc m -Octreotide was visually determined and then measured and expressed as the activity ratio of tumor to normal tissues (T/N). The differences between lung cancer and benign lung lesion and between SCLC and NSCLC, and between adenocarcinoma and squamous carcinoma were studied by statistical analysis. Moreover, the receiver operating characteristic ROC curves were plotted and the predicted probabilities and areas under the curve were calculated. Results: Fifty-one patients and fourteen patients in 65 cases were diagnosed as lung cancer and benign lung lesion by histopathological analysis, respectively. The sensitivity, specificity, positive predictive value and negative predictive value of 99 Tc m -Octreotide SPECT/CT in diagnosis of lung cancer were 92.2%, 85.7%, 95.9% and 75%, respectively. The area under ROC curve was 0.889 (P 99 Tc m -Octreotide SPECT/CT could play an important role in the diagnosis of lung cancer, and it may be useful for identifying SCLC and NSCLC. (authors)

  16. Fast and Automatic Ultrasound Simulation from CT Images

    Directory of Open Access Journals (Sweden)

    Weijian Cong

    2013-01-01

    Full Text Available Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  17. Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    International Nuclear Information System (INIS)

    Lee, Yun-Gyoo; Bang, Yung-Jue; Han, Sae-Won; Oh, Do-Youn; Chie, Eui Kyu; Jang, Jin-Young; Im, Seock-Ah; Kim, Tae-You; Kim, Sun-Whe; Ha, Sung Whan

    2011-01-01

    Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of 18 F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings. We consecutively enrolled 50 patients with BTC who underwent curative surgery. An 18 F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and 18 F-FDG PET/CT with the final diagnosis. Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% vs. 76%, p = 0.16) and accuracy (82% vs. 66%, p = 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% vs. 74%, p = 0.72) and negative predictive values for recurrence (73% vs. 47%, p = 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT vs. 76% [26/34] for ceCT alone, p = 0.03) without increasing the specificity, positive predictive value, and negative predictive value. 18 F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional 18 F-FDG PET/CT on ceCT significantly improves the

  18. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  19. The thin-section CT, pathological and clinical findings of peripheral small squamous cell lung carcinomas

    International Nuclear Information System (INIS)

    Yamamoto, Takahito; Saito, Haruhiro; Kondo, Tetsuro

    2010-01-01

    We analyzed thin-section CT, pathological, and clinical findings of peripheral lung squamous cell carcinomas, with diameters of less than 20 mm and compared these findings with solid type adenocarcinomas. CT findings of polygonal shapes, notches, pleural thickness, and cavities are more frequently found in squamous cell carcinomas than in adenocarcinomas. The pathological types can be classified in two groups: Solid types, Scirrhous types. The 5 year survival rate after resection is 64.5%, which is poorer than survival rate for solid type adenocarcinomas. It is vital to diagnose and treat peripheral squamous cell carcinomas as early as possible. (author)

  20. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zeniya, T.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T

    2001-07-21

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  1. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Science.gov (United States)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  2. Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update

    Directory of Open Access Journals (Sweden)

    Nakanishi R

    2016-06-01

    Full Text Available Rine Nakanishi, Mathew J Budoff Los Angeles Biomedical Research Institute, Harbor-UCLA Medical Center, Torrance, CA, USA Abstract: After a decade of clinical use of coronary computed tomographic angiography (CCTA to evaluate the anatomic severity of coronary artery disease, new methods of deriving functional information from CCTA have been developed. These methods utilize the anatomic information provided by CCTA in conjunction with computational fluid dynamics to calculate fractional flow reserve (FFR values from CCTA image data sets. Computed tomography-derived FFR (CT-FFR enables the identification of lesion-specific drop noninvasively. A three-dimensional CT-FFR modeling technique, which provides FFR values throughout the coronary tree (HeartFlow FFRCT analysis, has been validated against measured FFR and is now approved by the US Food and Drug Administration for clinical use. This technique requires off-site supercomputer analysis. More recently, a one-dimensional computational analysis technique (Siemens cFFR, which can be performed on on-site workstations, has been developed and is currently under investigation. This article reviews CT-FFR technology and clinical evidence for its use in stable patients with suspected coronary artery disease. Keywords: fractional flow reserve, coronary computed tomographic angiography, FFRCT, cFFR

  3. Clinical Usefulness of SPECT-CT in Patients with an Unexplained Pain in Metal on Metal (MOM) Total Hip Arthroplasty.

    Science.gov (United States)

    Berber, Reshid; Henckel, Johann; Khoo, Michael; Wan, Simon; Hua, Jia; Skinner, John; Hart, Alister

    2015-04-01

    SPECT-CT is increasingly used to assess painful knee arthroplasties. The aim of this study was to evaluate the clinical usefulness of SPECT-CT in unexplained painful MOM hip arthroplasty. We compared the diagnosis and management plan for 19 prosthetic MOM hips in 15 subjects with unexplained pain before and after SPECT-CT. SPECT-CT changed the management decision in 13 (68%) subjects, Chi-Square=5.49, P=0.24. In 6 subjects (32%) pain remained unexplained however the result reassured the surgeon to continue with non-operative management. SPECT-CT should be reserved as a specialist test to help identify possible causes of pain where conventional investigations have failed. It can help reassure surgeons making management decisions for patients with unexplained pain following MOM hip arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Development of a nomogram combining clinical staging with 18F-FDG PET/CT image features in non-small-cell lung cancer stage I-III

    International Nuclear Information System (INIS)

    Desseroit, Marie-Charlotte; Visvikis, Dimitris; Majdoub, Mohamed; Hatt, Mathieu; Tixier, Florent; Perdrisot, Remy; Cheze Le Rest, Catherine; Guillevin, Remy

    2016-01-01

    Our goal was to develop a nomogram by exploiting intratumour heterogeneity on CT and PET images from routine 18 F-FDG PET/CT acquisitions to identify patients with the poorest prognosis. This retrospective study included 116 patients with NSCLC stage I, II or III and with staging 18 F-FDG PET/CT imaging. Primary tumour volumes were delineated using the FLAB algorithm and 3D Slicer trademark on PET and CT images, respectively. PET and CT heterogeneities were quantified using texture analysis. The reproducibility of the CT features was assessed on a separate test-retest dataset. The stratification power of the PET/CT features was evaluated using the Kaplan-Meier method and the log-rank test. The best standard metric (functional volume) was combined with the least redundant and most prognostic PET/CT heterogeneity features to build the nomogram. PET entropy and CT zone percentage had the highest complementary values with clinical stage and functional volume. The nomogram improved stratification amongst patients with stage II and III disease, allowing identification of patients with the poorest prognosis (clinical stage III, large tumour volume, high PET heterogeneity and low CT heterogeneity). Intratumour heterogeneity quantified using textural features on both CT and PET images from routine staging 18 F-FDG PET/CT acquisitions can be used to create a nomogram with higher stratification power than staging alone. (orig.)

  5. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  6. {sup 18}F-FDG PET/CT quantification in head and neck squamous cell cancer: principles, technical issues and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Manca, Gianpiero; Volterrani, Duccio [University Hospital of Pisa, Regional Center of Nuclear Medicine, Pisa (Italy); Vanzi, Eleonora [University Hospital of Siena, Service of Medical Physics, Siena (Italy); Rubello, Domenico; Grassetto, Gaia [Santa Maria della Misericordia Rovigo Hospital, Department of Nuclear Medicine, Rovigo (Italy); Giammarile, Francesco [Faculte Charles Merieux, Medecine Nucleaire, Centre Hospitalier and Biophysique, Lyon (France); Wong, Ka Kit [University of Michigan Hospital, Nuclear Medicine/Radiology Department, Ann Arbor, MI (United States); Nuclear Medicine Service, Department of Veterans Affairs Health System, Ann Arbor, MI (United States); Perkins, Alan C. [University of Nottingham, Department of Radiological Sciences, School of Medicine, Nottingham (United Kingdom); Colletti, Patrick M. [Southern University of California, Department of Radiology, Los Angeles, CA (United States)

    2016-07-15

    {sup 18}F-FDG PET/CT plays a crucial role in the diagnosis and management of patients with head and neck squamous cell cancer (HNSCC). The major clinical applications of this method include diagnosing an unknown primary tumour, identifying regional lymph node involvement and distant metastases, and providing prognostic information. {sup 18}F-FDG PET/CT is also used for precise delineation of the tumour volume for radiation therapy planning and dose painting, and for treatment response monitoring, by detecting residual or recurrent disease. Most of these applications would benefit from a quantitative approach to the disease, but the quantitative capability of {sup 18}F-FDG PET/CT is still underused in HNSCC. Innovations in PET/CT technology promise to overcome the issues that until now have hindered the employment of dynamic procedures in clinical practice and have limited ''quantification'' to the evaluation of standardized uptake values (SUV), de facto a semiquantitative parameter, the limits of which are well known to the nuclear medicine community. In this paper the principles of quantitative imaging and the related technical issues are reviewed so that professionals involved in HNSCC management can reflect on the advantages of ''true'' quantification. A discussion is then presented on how semiquantitative information is currently used in clinical {sup 18}F-FDG PET/CT applications in HNSCC, by discussing the improvements that could be obtained with more advanced and ''personalized'' quantification techniques. (orig.)

  7. Basic principles of magnetic resonance imaging in cerebral ischemia and initial clinical experience

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Solomon, M.; Newton, T.H.; Weinstein, P.; Schmidley, J.; Norman, D.

    1985-01-01

    NMR tomography proved to be a method superior to computerized tomography (CT) in terms of sensitivity in the diagnosis of pathological changes in the brain. The article on hand gives a brief survey on the principle of the method and demonstrates the superiority of NMR tomography to CT exemplified by images taken from a number of cases. Instrumental factors influencing diagnosis of cerebral ischaemie are discussed. Clinical studies performed on more than 20 partients with suspected infarct revealed the superiority of NMR tomography to CT. (MG) [de

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  9. Implementing radiographic CT head reporting: The experiences of students and managers

    International Nuclear Information System (INIS)

    Clarke, Ruth; Allen, David; Arnold, Paul; Snaith, Beverley

    2014-01-01

    Introduction: In the face of growing demand in radiology, skill mix initiatives have sought to improve and expand service provision. Within the UK radiographer reporting is now widespread, although the growth in computerised tomography (CT) head reporting has not been as rapid as anticipated. The literature in this area is limited, but case studies have highlighted the successful implementation of this training through new radiographer roles in practice. Method: A cross-sectional survey was developed to elicit information from radiographers and managers on their experiences before, during and after post-graduate training in CT head reporting. Results: Seventy one responses were received comprising 48 past students (n = 48/111; 43.2%) and 23 service managers (n = 23/67; 34.3%). Key factors for the development were personal continual professional development for students and departmental need for managers. Challenges during training included a lack of study time due to staff shortages and access to radiologist mentors. Only 48.8% of students responding have gone on to use the new skills in practice cited reasons include staff shortages, resistance from radiologists and increase in radiological staffing. Conclusions: This qualitative study has demonstrated that those trusts who have implemented CT head reporting have evidenced perceptible benefits for both the department and individuals. Those radiographers who are successfully reporting have shown themselves to be highly motivated and persistent in their development

  10. Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques

    International Nuclear Information System (INIS)

    Bettinardi, Valentino; Picchio, Maria; Di Muzio, Nadia; Gianolli, Luigi; Gilardi, Maria Carla; Messa, Cristina

    2010-01-01

    Purpose: To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. Methods: Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. Results: RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. Conclusions: RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.

  11. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    International Nuclear Information System (INIS)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis; Baixas, Cecile; Galinier, Michel; Deken, Valerie; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2004-01-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean±SD value: 34±12.9 vs 43±13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean±SD value: 17±2.75 vs 14±3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  12. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis [Department of Radiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Baixas, Cecile; Galinier, Michel [Department of Cardiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Deken, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France); Remy, Jacques; Remy-Jardin, Martine [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France)

    2004-05-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean{+-}SD value: 34{+-}12.9 vs 43{+-}13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean{+-}SD value: 17{+-}2.75 vs 14{+-}3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  13. Technique and clinical applications of full-inflation and end-exhalation controlled-ventilation chest CT in infants and young children

    International Nuclear Information System (INIS)

    Long, F.R.; Castile, R.G.

    2001-01-01

    Background. The inability of young children to cooperate with breath holding limits the usefulness of chest CT. Objective. To describe the technique and utility of a non-invasive method called controlled-ventilation CT (CVCT) for obtaining motion-free full-inflation and end-exhalation images of the lung in infants and young children. Materials and methods. Eighty-seven children (ages 1 week to 5 years, mean 2 years) underwent CVCT of the chest during suspended respiration at full-lung inflation and end-exhalation for a variety of clinical indications. Respiratory pauses were produced using conscious sedation and positive-pressure face-mask ventilation. Forty-one of 87 children had recordings of respiratory motion during CVCT. Results. Respiratory pause lengths increased with age (P < 0.003), were highly reproducible (r = 0.85), and lasted sufficiently long to be practical for full-inflation (24 ± 9 s) and end-exhalation (12 ± 5 s) CT scanning. Full-inflation CVCT was useful in evaluating tracheal and bronchial stenosis, bronchial wall thickening, early bronchiectasis, bronchial fistula, extent of interstitial fibrosis, and lung nodules. End-exhalation CVCT was useful in evaluating tracheomalacia and air trapping. Conclusion. Controlled-ventilation chest CT is a practical and reliable technique that promises to be clinically useful for a number of clinical indications in infants and young children. (orig.)

  14. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    International Nuclear Information System (INIS)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-01-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with 18 F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy

  15. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F [Duke University Medical Center, Durham, NC (United States)

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  16. Usefulness and limit of CT diagnosis on appendicitis

    International Nuclear Information System (INIS)

    Kuchiki, Megumi; Takanashi, Toshiyasu; Yamaguchi, Koichi.

    1997-01-01

    CT was performed in 104 patients with abdominal pain suspected appendicitis. CT showed positive finding (abnormal appendix, appendicolith, pericecal inflammatory change, fluid collection, LN swelling, abscess) and complication of appendicitis clearly. CT diagnosis showed high accuracy than clinical diagnosis. CT proved its usefulness especially only CT imaging showed the correct diagnosis. On the other hand, diverticulitis and terminal ileitis common diagnostic disease of appendicitis showed similar clinical appearance and CT image, caused to be difficult to diagnose correctly. In the cases showing similar image to appendicitis or atypical image, CT also proved its limit of the diagnosis on appendicitis. (author)

  17. Oxygen-enhanced MRI vs. quantitatively assessed thin-section CT: Pulmonary functional loss assessment and clinical stage classification of asthmatics

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1100, Shimogatou, Chuo, Yamanashi, 409-3898 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2 Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Takenaka, Daisuke; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2011-01-15

    Purpose: The purpose of this study was to prospectively compare the efficacy of oxygen-enhanced MR imaging (O{sub 2}-enhanced MRI) and CT for pulmonary functional loss assessment and clinical stage classification of asthmatics. Materials and methods: O{sub 2}-enhanced MRI, CT and %FEV{sub 1} measurement were used 34 consecutive asthmatics classified into four stages ('Mild Intermittent [n = 7]', 'Mild Persistent [n = 8], 'Moderate Persistent [n = 14]' and 'Severe Persistent [n = 5]'). Relative enhancement ratio maps for every subject were generated, and determine mean relative enhancement ratios (MRERs). Mean lung density (MLD) and the airway wall area (WA) corrected by body surface area (WA/BSA) were also measured on CT. To compare the efficacy of the two methods for pulmonary functional loss assessment, all indexes were correlated with %FEV{sub 1}. To determine the efficacy of the two methods for clinical stage classification, all parameters for the four clinical stages were statistically compared. Results: %FEV{sub 1} showed fair or moderate correlation with all parameters (0.15 {<=} r{sup 2} {<=} 0.30, p < 0.05). WA, WA/BSA and MRER of the 'Severe Persistent' group were significantly larger than those of 'Mild Intermittent' and 'Mild Persistent' groups (p < 0.05), and MRER of the 'Moderate Persistent' group significantly lower than that of the 'Mild Intermittent' group (p < 0.05). Conclusion: O{sub 2}-enhanced MRI is as effective as CT for pulmonary functional loss assessment and clinical stage classification of asthmatics.

  18. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair.

    Science.gov (United States)

    Donayre, Carlos E; Zarins, Christopher K; Krievins, Dainis K; Holden, Andrew; Hill, Andrew; Calderas, Carlos; Velez, Jaime; White, Rodney A

    2011-03-01

    All current aortic endografts depend on proximal and distal fixation to prevent migration. However, migration and rupture can occur, particularly in patients with aortic necks that are short or angulated, or both. We present our initial clinical experience with a new sac-anchoring endoprosthesis designed to anchor and seal the device within the aneurysm sac. The initial worldwide experience using a new endoprosthesis for the treatment of aortic aneurysms (Nellix Endovascular, Palo Alto, Calif) was reviewed. The endoprosthesis consists of dual balloon-expandable endoframes surrounded by polymer-filled endobags designed to obliterate the aneurysm sac and maintain endograft position. Clinical results and follow-up contrast computed tomography (CT) scans at 30 days and 6 and 12 months were reviewed. The endograft was successfully deployed in 21 patients with infrarenal aortic aneurysms measuring 5.7 ± 0.7 cm (range, 4.3-7.4 cm). Two patients with common iliac aneurysms were treated with sac-anchoring extenders that maintained patency of the internal iliac artery. Infusion of 71 ± 37 mL of polymer (range, 19-158 mL) into the aortic endobags resulted in complete aneurysm exclusion in all patients. Mean implant time was 76 ± 35 minutes, with 33 ± 17 minutes of fluoroscopy time and 180 ± 81 mL of contrast; estimated blood loss was 174 ± 116 mL. One patient died during the postoperative period (30-day mortality, 4.8%), and one died at 10 months from non-device-related causes. During a mean follow-up of 8.7 ± 3.1 months and a median of 6.3 months, there were no late aneurysm- or device-related adverse events and no secondary procedures. CT imaging studies at 6 months and 1 year revealed no increase in aneurysm size, no device migration, and no new endoleaks. One patient had a limited proximal type I endoleak at 30 days that resolved at 60 days and remained sealed. One patient has an ongoing distal type I endoleak near the iliac bifurcation, with no change in aneurysm

  19. SU-F-I-51: CT/MR Image Deformation: The Clinical Assessment QA in Target Delineation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C; Chen, Y [Monmouth Medical Center, Long Branch, NJ (United States)

    2016-06-15

    Purpose: To study the deformation effects in CT/MR image registration of head and neck (HN) cancers. We present a clinical indication in guiding and simplifying registration procedures of this process while CT images possessed artifacts. Methods: CT/MR image fusion provides better soft tissue contrast in intracranial GTV definition with artifacts. However, whether the fusion process should include the deformation process is questionable and not recommended. We performed CT/MR image registration of a HN patient with tonsil GTV and nodes delineation on Varian Velocity™ system. Both rigid transformation and deformable registration of the same CT/MR imaging data were processed separately. Physician’s selection of target delineation was implemented to identify the variations. Transformation matrix was shown with visual identification, as well as the deformation QA numbers and figures were assessed. Results: The deformable CT/MR images were traced with the calculated matrix, both translation and rotational parameters were summarized. In deformable quality QA, the calculated Jacobian matrix was analyzed, which the min/mean/max of 0.73/0/99/1.37, respectively. Jacobian matrix of right neck node was 0.84/1.13/1.41, which present dis-similarity of the nodal area. If Jacobian = 1, the deformation is at the optimum situation. In this case, the deformation results have shown better target delineation for CT/MR deformation than rigid transformation. Though the root-mean-square vector difference is 1.48 mm, with similar rotational components, the cord and vertebrae position were aligned much better in the deformable MR images than the rigid transformation. Conclusion: CT/MR with/without image deformation presents similar image registration matrix; there were significant differentiate the anatomical structures in the region of interest by deformable process. Though vendor suggested only rigid transformation between CT/MR assuming the geometry remain similar, our findings

  20. SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, N; Zhang, J; Happersett, L; Kadbi, M; Mechalakos, J; Deasy, J; Hunt, M [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master

  1. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    International Nuclear Information System (INIS)

    Chen Yang; Shi Luyao; Shu Huazhong; Luo Limin; Coatrieux, Jean-Louis; Yin Xindao; Toumoulin, Christine

    2013-01-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors. (paper)

  2. Intracranial tuberculosis in children: CT appearance and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, R C; Burton, E M; Gerald, B E [Le Bonheur Children' s Medical Center, Memphis, TN (United States). Dept. of Radiology Tennessee Univ., Memphis (United States); Barrett, F F; Leggiadro, R J [Le Bonheur Children' s Medical Center, Memphis, TN (United States). Dept. of Pediatrics Tennessee Univ., Memphis (United States); Lasater, O E [Le Bonheur Children' s Medical Center, Memphis, TN (United States). Dept. of Pathology Tennessee Univ., Memphis (United States)

    1991-05-01

    We retrospectively evaluated the CT studies of 9 children who presented with intracranial tuberculosis during 1981-1987, and compared their radiographic appearance with the clinical outcome. The most common radiographic findings were: 1) Ventriculomegaly (7/9), 2) tuberculoma formation (6/9), and 3) infarction (4/9). Of 7 patients with ventriculomegaly, 3 required a ventricular shunt and 2 had spontaenous resolution of ventricular dilatation. Four children with ventriculomegaly were moderately or severely retarded, one had cognitive dysfunction, and one was neurologically normal. Four of six children with tuberculoma also had infarction and/or ventriculomegaly; of these four children, three were moderately or severely retarded. Two patients with tuberculoma as the only intracranial abnormality had complete resolution or the granuloma with normal neurologic outcome following antituberculous therapy. The four children with large vessel infarction also had ventriculomegaly; three had poor clinical outcome. The presence of tuberculoma alone is not necessarily predictive of poor neurologic outcome; age less than 20 months, infarct, and/or ventriculomegaly are usually associated with sequelae. (orig.).

  3. Diagnostic Performance of CT Colonography for the Detection of Colorectal Polyps

    International Nuclear Information System (INIS)

    Yun, Ji Young; Ro, Hee Jeong; Choi, Jung Bin; Chung, Ji Eun; Kim, Yong Jin; Suh, Won Hyuck; Lee, Jong Kyun; Park, Jong Beom

    2007-01-01

    To investigate the diagnostic value of CT colonography for the detection of colorectal polyps. From December 2004 to December 2005, 399 patients underwent CT colonography and follow-up conventional colonoscopy. We excluded cases of advanced colorectal cancer. We retrospectively analyzed the CT colonography findings and follow-up conventional colonoscopy findings of 113 patients who had polyps more than 6 mm in diameter. Radiologists using 3D and 2D computer generated displays interpreted the CT colonography images. The colonoscopists were aware of the CT colonography findings before the procedure. CT colonography detected 132 polyps in 107 of the 113 patients and conventional colonoscopy detected 114 colorectal polyps more than 6 mm in diameter in 87 of the 113 patients. The sensitivity of CT colonography analyzed per polyp was 91% (41/45) for polyps more than 10 mm in diameter and 89% (101/114) for polyps more than 6 mm in diameter. Thirteen polyps were missed by CT colonography and were detected on follow-up conventional colonoscopy. CT colonography is a sensitive diagnostic tool for the detection of colorectal polyps and adequate bowel preparation, optimal bowel distention and clinical experience are needed to reduce the rate of missing appropriate lesions

  4. Clinical impact of 18F-FDG-PET/CT in the extra cardiac work-up of patients with infective endocarditis

    DEFF Research Database (Denmark)

    Asmar, Ali; Ozcan, Cengiz; Diederichsen, Axel C P

    2014-01-01

    OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement, the progno......OBJECTIVE: The purpose of this study was to assess the clinical importance of (18)F-FDG-PET/CT used in the extra cardiac work-up of patients with infective endocarditis (IE). BACKGROUND: IE is a serious condition with a significant mortality. Besides the degree of valvular involvement...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  8. Initial experience with FDG-PET/CT in the evaluation of breast cancer

    International Nuclear Information System (INIS)

    Tatsumi, Mitsuaki; Cohade, Christian; Mourtzikos, Karen A.; Wahl, Richard L.; Fishman, Elliot K.

    2006-01-01

    We retrospectively reviewed FDG-PET/CT images in patients with breast cancer to determine whether PET/CT improved the level of diagnostic confidence as compared with PET and to compare PET/CT and CT findings at the location of suspected malignancies. The study included 75 patients with known breast cancer. The initial PET/CT study for each patient was retrospectively reviewed to determine whether improved diagnostic confidence (IDC) regarding lesion localization and characterization was observed with PET/CT as compared with PET alone. PET/CT and CT findings were compared regarding lesion characterization and staging in 69 of the 75 patients, and in the case of discordant findings, comparison with histological or informative follow-up results was also performed. Fifty of the 75 patients exhibited increased FDG uptake in a total of 95 regions. In the comparison of PET/CT and PET, PET/CT resulted in IDC in 30 (60%) of these 50 patients and in 52 (55%) of the 95 regions. In the comparison between PET/CT and CT in 69 patients, PET/CT demonstrated a significantly better accuracy than CT (P<0.05). PET/CT showed definitely positive findings in 60 regions with malignancies, among which CT exhibited positive findings in 43 (72%). PET/CT and CT accurately staged 59 (86%) and 53 (77%) of the 69 patients, respectively. (orig.)

  9. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  10. Clinical significance of changes of serum contents of IL-8, CT, BGF and T in elderly men with osteoporosis

    International Nuclear Information System (INIS)

    Zhou Jian

    2011-01-01

    Objective: To study the clinical significance of changes of serum contents of IL-8 calcitonin (CT) bone glaprotein (BGF) and testosterone (T) in elderly men with osteoporosis. Methods: The serum IL-8, CT, BGP and T levels were determined with RIA in 33 elderly men with osteoporosis and 35 controls. Results: The serum levels of IL-8 were significantly higher, but levels of CT, BGP and T were significantly lower in the elderly men with osteoporosis than those in controls (P<0.01). There were significantly negative relationship between the serum levels of IL-8 and serum levels of CT, BGP and T (r = -0.4712, -0.5014, -0.4915, P<0.05). Conclusion: The changes of IL-8, CT, BGP and T levels correctly reflected increase of bone absorption with less osteogenesis, which was characteristic in osteoporosis. (authors)

  11. The application of PET/CT in immunoglobulin G4-related disease

    International Nuclear Information System (INIS)

    Zhang Huiwei; Zhao Jun

    2013-01-01

    Immunoglobulin G4 (IgG4)-related disease is a kind of new systemic entity characterized by mass-forming lesions in various organs that consist of lymphoplasmacytic infiltrates and fibrosclerosis with numerous IgG4-positive plasma cells. PET/CT has been widely used in clinical as a whole body examination that earned plenty of successful experience, especially in multiple locations and organs cancer such as lymphoma. PET/CT also has a potential application in IgG4-related diseases as its feature of systemic. (authors)

  12. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    Energy Technology Data Exchange (ETDEWEB)

    Bunt, Fabian van de [VU University Medical Center, Amsterdam (Netherlands); Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul [Kaiser Permanente, Los Angeles, CA (United States)

    2015-11-15

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  13. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability

    International Nuclear Information System (INIS)

    Bunt, Fabian van de; Pearl, Michael L.; Lee, Eric K.; Peng, Lauren; Didomenico, Paul

    2015-01-01

    Recent studies have challenged the accuracy of conventional measurements of glenoid version. Variability in the orientation of the scapula from individual anatomical differences and patient positioning, combined with differences in observer measurement practices, have been identified as sources of variability. The purpose of this study was to explore the utility and reliability of clinically available software that allows manipulation of three-dimensional images in order to bridge the variance between clinical and anatomic version in a clinical setting. Twenty CT scans of normal glenoids of patients who had proximal humerus fractures were measured for version. Four reviewers first measured version in a conventional manner (clinical version), measurements were made again (anatomic version) after employing a protocol for reformatting the CT data to align the coronal and sagittal planes with the superior-inferior axis of the glenoid, and the scapular body, respectively. The average value of clinical retroversion for all reviewers and all subjects was -1.4 (range, -16 to 21 ), as compared to -3.2 (range, -21 to 6 ) when measured from reformatted images. The mean difference between anatomical and clinical version was 1.9 ± 5.6 but ranged on individual measurements from -13 to 26 . In no instance did all four observers choose the same image slice from the sequence of images. This study confirmed the variation in glenoid version dependent on scapular orientation previously identified in other studies using scapular models, and presents a clinically accessible protocol to correct for scapular orientation from the patient's CT data. (orig.)

  14. Assessing student clinical learning experiences.

    Science.gov (United States)

    Nehyba, Katrine; Miller, Susan; Connaughton, Joanne; Singer, Barbara

    2017-08-01

    This article describes the use of an activity worksheet and questionnaire to investigate the learning experience of students on clinical placement. The worksheet measures the amount of time students spend in different learning activities, and the questionnaire explores student satisfaction and preferred learning activities. An activity worksheet and questionnaire … investigate[d] the learning experiences of students on clinical placement METHODS: The activity worksheet and questionnaire were used in a cohort pilot study of physiotherapy students on clinical placement. The activity worksheet provides details of the amount of time students engage in a range of clinical and non-clinical tasks while on placement, such as time spent treating patients, working individually, working with their peers and engaging in reflective practice. In combination with the questionnaire results, it allows clinicians to gain an understanding of the clinical learning environment experienced by their students. The data collected using these tools provide a description of the students' activities while undertaking the clinical placement. This information may guide the refinement of the clinical experience, and offers an opportunity to individualise learning activities to match students' needs and preferences. © 2016 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  15. Clinical evaluation of high-resolution CT, 1. CT diagnosis of liver tumors and its limit

    Energy Technology Data Exchange (ETDEWEB)

    Araki, T [Tokyo Univ. (Japan). Faculty of Medicine

    1980-03-01

    To estimate diagnostic accuracy of CT in liver tumors, CT diagnosis in 120 patients with primary hepatocellular carcinoma was discussed. As a result, primary hepatocellular carcinoma less than 2 cm in diameter could not be visualized by CT. Even tumors between 4 and 8 cm in diameter showed false negative caused by isodense tumors on images of 4 patients. To improve the detectability of liver tumors by CT, the higher resolution of low contrast regions on images are required. As a method to improve qualitative diagnosis of liver tumors, rapid intravenous injection of contrast medium was performed on 42 patients with liver tumors, As a result, images reflecting vascularity of tumors were obtained, and the differential diagnosis was possible to some extent by observing the movement of the contrast. Especially, cavernous hemangioma could be distinguished from hepatocellular carcinoma, because cavernous hemangioma showed specific images and could be diagnosed accurately.

  16. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  17. Clinical role of the skull base with increased uptake of 99mTc-MDP on SPECT/CT fused imaging with patients of nasopharyngeal

    International Nuclear Information System (INIS)

    Yao Hongxia; Zhang Jinshan; Liu Sheng

    2009-01-01

    Objective: To investigate the clinical role of the fused skull single photon emission computed tomographic and computed tomographic images (SPECT/CT) when there was 'hot' in the skull base of patients with NPC. Methods: 99 mTc-MDP SPECT/ CT and MRI were performed in a week in 44 patients (30 with first-visited cases and 14 with return-visited, 38 cases of poorly differentiated squamous cell carcinoma and 6 cases of undifferentiated cancer, 14 with headache). Region of interests (ROI) were drawn on the area of the suspected skull base and the upper cervical vertebral body on the same slice. A lesion-to-spine (L/S) ratio was interpreted on SPECT/CT as normal, benign, or malignant. L/S>1 indicated malignant skull base bone involvement (SBBI). Ten patients were studied as controls. Results: (1)Of the 44 study patients, 24 had SBBI (55%) based on SPECT/CT detecting skull base bone lesions with L/S =1.83±0.69. Twenty patients had normal or benign bone lesions on SPECT/CT with L/S =0.68±0.13. There was statistic significance compared SBBI with no SBBI subgroups (P 0.05). The numbers of SBBI had no relationship with positive rate of SPECT/CT (P >0.05). (3)There was no obviously increased uptake in the skull base in the 10 control patients (L/S<1). Conclusion: The skull SPECT/CT was recommended as one of clinical diagnosis tool for SBBI from NPC. Patients with headache should be highly suspected whether tumor cells involved the skull base bone or not. Further accumulation of other clinical factors would clarify the values of SPECT/CT. (authors)

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  19. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  20. Acute sialadenitis in children and adolescents: CT findings and clinical manifestations according to glandular involvement

    International Nuclear Information System (INIS)

    Lee, A. Leum; Kim, Young Tong; Han, Jong Kyu; Jou, Sung Shick; Jung, Du Shin

    2008-01-01

    This study was designed to compare the CT findings and clinical manifestations in children and adolescents with acute sialadenitis according to the involved salivary glands. The study included fifty children and adolescents (34 boys, 16 girls) with acute sialadenitis that was diagnosed during the past five years. All of the subjects were divided into three groups: group I (parotid gland involvement, n = 16), group II (submandibular gland involvement, n = 20) and group III (involvement of both glands, n 14). We analyzed the presence of an abscess, sialolith, bilaterality, cellulitis and lymphadenopathy on CT scans. The analyzed clinical data were age, sex, lymphadenopathy, pain, swelling, presence of a mass, tonsillitis, treatment period and surgical treatment if it was performed. The presence of an abscess, sialolith, cellulitis, swelling, age, presence of a palpable mass and treatment period were statistically significant factors for the patients in the three groups. An abscess was combined only in group I patients. There was a high rate of sialolith in group II patients and cellulitis in group III patients as seen on CT scans. Swelling in group II patients and group III patients and the presence of a palpable mass in group I patients were identified as clinical manifestations. Age was younger in group I patients (mean age, 5.3 years) than in group II patients (mean age, 12.9 years) and group III patients (mean age, 15.2 years). The treatment period was longer for group I patients. For acute sialadenitis in children and adolescents, age, presence of an abscess, sialolith, cellulitis, swelling, presence of a palpable mass and treatment period were different according to the involved salivary glands

  1. Detection of low-grade prosthetic joint infections using 99mTc-antigranulocyte SPECT/CT: initial clinical results

    International Nuclear Information System (INIS)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus; Feist, Markus; Mueller, Peter Ernst

    2010-01-01

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with 99m Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using 99m Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with 99m Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  2. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system

    International Nuclear Information System (INIS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2002-01-01

    The aim of this study was to evaluate a computer-aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Eighty-eight consecutive spiral-CT examinations were reported by two radiologists in consensus. All examinations were reviewed using a CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm is designed to detect nodules with diameters of at least 5 mm. A total of 153 nodules were detected with at least one modality (radiologists in consensus, CAD, 85 nodules with diameter <5 mm, 68 with diameter ≥5 mm). The results of automatic nodule detection were compared to nodules detected with any modality as gold standard. Computer-aided diagnosis correctly identified 26 of 59 (38%) nodules with diameters ≥5 mm detected by visual assessment by the radiologists; of these, CAD detected 44% (24 of 54) nodules without pleural contact. In addition, 12 nodules ≥5 mm were detected which were not mentioned in the radiologist's report but represented real nodules. Sensitivity for detection of nodules ≥5 mm was 85% (58 of 68) for radiologists and 38% (26 of 68) for CAD. There were 5.8±3.6 false-positive results of CAD per CT study. Computer-aided diagnosis improves detection of pulmonary nodules at spiral CT and is a valuable second opinion in a clinical setting for lung cancer screening despite of its still limited sensitivity. (orig.)

  3. Clinical application of helical CT 3D reconstruction for the dental orthopaedics

    International Nuclear Information System (INIS)

    Han Benyi; Jiang Xiaolu; Li Hongru

    2005-01-01

    Objective: To evaluate the clinical application of helical CT 3D reconstruction technique in the dental orthopaedics. Methods: The helical CT was performed with 3.0 mm slice thickness and 1.0 pitch in 41 patients with dental orthopaedics. The 3D reconstructions, including maximum intensity projection (MIP), surface shaded display (SSD), and multiplanar reconstructions (MPR), were made for all the cases. Results: Thirty-seven of the 41 patients showed malalignment, tilt, rotation, overlap of the teeth and the different space between the longitudinal axes of the teeth. Twenty-five cases of them have shown 36 buried teeth in all. The axial images covered all the information. SSD demonstrated the external contours and entire morphologies of the teeth and the mandible with the relationship of the teeth alignment and the mandible. MIP clearly manifested the full view and the longitudinal alignment of the teeth. Among the 36 buried teeth, there were 29 palatally and 7 labially presented teeth, and they were morphologically delineated on MIP through various angles. Conclusion: The helical CT 3D reconstruction is a new technique to display the stereoscopic configuration of teeth. The combination of axial images and MIP, SSD, and MPR provides valuable anatomic and diagnostic information helpful for the surgeons to structure and determine the treatment protocol for the dental orthopaedics. (authors)

  4. PET and PET/CT with radiolabeled choline in prostate cancer: a critical reappraisal of 20 years of clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Giovacchini, Giampiero; Giovannini, Elisabetta; Leoncini, Rossella; Riondato, Mattia; Ciarmiello, Andrea [S. Andrea Hospital, Nuclear Medicine Department, La Spezia (Italy)

    2017-09-15

    We here aim to provide a comprehensive and critical review of the literature concerning the clinical applications of positron emission tomography/computed tomography (PET/CT) with radiolabeled choline in patients with prostate cancer (PCa). We will initially briefly summarize the historical context that brought to the synthesis of [{sup 11}C]choline, which occurred exactly 20 years ago. We have arbitrarily grouped the clinical studies in three different periods, according to the year in which they were published and according to their relation with their applications in urology, radiotherapy and oncology. Studies at initial staging and, more extensively, studies in patients with biochemical failure, as well as factors predicting positive PET/CT will be reviewed. The capability of PET/CT with radiolabeled choline to provide prognostic information on PCa-specific survival will also be examined. The last sections will be devoted to the use of radiolabeled choline for monitoring the response to androgen deprivation therapy, radiotherapy, and chemotherapy. The accuracy and the limits of the technique will be discussed according to the information available from standard validation processes, including biopsy or histology. The clinical impact of the technique will be discussed on the basis of changes induced in the management of patients and in the evaluation of the response to therapy. Current indications to PET/CT, as officially endorsed by guidelines, or as routinely performed in the clinical practice will be illustrated. Emphasis will be made on methodological factors that might have influenced the results of the studies or their interpretation. Finally, we will briefly highlight the potential role of positron emission tomography/magnetic resonance and of new radiotracers for PCa imaging. (orig.)

  5. Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Jeremiah, E-mail: jeremiah.sanders@duke.edu [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Clinical Imaging Physics Group, Duke University, Durham, North Carolina 27710 (United States); Hurwitz, Lynne [Department of Radiology, Duke University, Durham, North Carolina 27710 (United States); Samei, Ehsan [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Clinical Imaging Physics Group, Duke University, Durham, North Carolina 27710 and Departments of Physics, Biomedical Engineering, Electrical and Computer Engineering, Duke University, Durham, North Carolina 27710 (United States)

    2016-10-15

    Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this

  6. Awareness of radiation exposure of thoracic CT scans and conventional radiographs: what do non-radiologists know?

    International Nuclear Information System (INIS)

    Heyer, C.M.; Peters, S.; Lemburg, S.; Nicolas, V.

    2007-01-01

    Purpose: Assessment of the knowledge of non-radiological physicians concerning radiation exposure during radiological procedures on the thorax. Material and Methods: 124 non-radiological physicians from the departments of surgery, internal medicine, anesthesiology, and neurology at a university hospital were questioned during a four-week period using a standardized questionnaire as to the effective dose (ED) of different radiological procedures on the thorax. The interviewees were asked to estimate the ED of chest X-rays and CT examinations and to compare these with the ED of other radiological methods. Length of professional experience, field of clinical training, and hierarchical position were also documented. The T-test and chi-square test were used for statistical analysis. Results: 119/124 (96.0 %) physicians with an average work experience of 8.2 years (0.3 - 32 years) were willing to participate. 47/119 (39.5 %) correctly estimated the ED of conventional chest X-ray (0.01 - 0.1 mSv), and 40/119 (33.6 %) correctly gauged the ED of adult chest CT (1 - 10 mSv). The ED of cardiac CT and pediatric chest CT without dose reduction (10 - 100 mSv) were correctly judged by 31/119 (26.1 %) and 32/119 (26.9 %), respectively. The correct ratio of the ED of chest X-ray to that of chest CT (factor 100 - 1000) was given by 28/119 (23.5 %), while 86/119 (72.3 %) underestimated the ratio. 50/119 (42.0 %) and 35/119 (29.4 %) correctly stated that the ED of pediatric chest CT without dose reduction and that of cardiac CT are greater than that of adult chest CT. 24/119 (20.2 %) and 10/119 (8.4 %) thought that the ED of low-dose chest CT is smaller than that of chest X-ray or chest MRI, respectively. The length of professional experience, field of clinical training, and hierarchical position of the participants did not have a significant influence on the test results. (orig.)

  7. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT; Fruehes klinisches Management nach Polytrauma mit 1- und 4-Schicht-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kloeppel, R.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schreiter, D. [Chirurgische Intensivtherapieabteilung, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany); Dietrich, J. [Abt. Neuroradiologie der Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Josten, C. [Klinik und Poliklinik fuer Unfall- und Wiederherstellungschirurgie, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany)

    2002-07-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of {approx}30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by {approx}4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [German] Die klinische Erstversorgung Polytraumatisierter schliesst inzwischen in vielen Unfallkliniken den fruehzeitigen Einsatz der Spiral-CT ein. Kann die neuerlich eingefuehrte Mehrschicht-Spiral-CT Ergebnisse und Patientenmanagement weiter verbessern?Nach lebensrettenden Sofortmassnahmen, Thoraxroentgen und Notsonographie im Schockraum erfolgte die CT: Von 1998-2000 wurden 241 Patienten mit einem 1-Schicht-Spiral-CT (Somatom plus 4) und in 2001 79 Patienten mit einem 4-Schicht-Spiral-CT (Somatom VZ, beide Siemens Med. Sol.) untersucht. Klinisch ausgewaehlte Extremitaetenaufnahmen wurden ergaenzt.359 von 360 Untersuchungen verliefen erfolgreich

  8. CT-guided conformal cryoablation for peripheral NSCLC: Initial experience

    International Nuclear Information System (INIS)

    Zhang, Xiao; Tian, Jinlin; Zhao, Lei; Wu, Bin; Kacher, Daniel S.; Ma, Xuyang; Liu, Shurong; Ren, Chao; Xiao, Yue-Yong

    2012-01-01

    Purpose: To study the feasibility of CT-guided and monitored percutaneous conformal cryoablation of Non-Small Cell Lung Cancer for patients who are not suitable for surgical resection. Materials and method: CT-guided percutaneous conformal cryoablation was performed on 46 patients with peripheral Non-Small Cell Lung Cancer. Patients with tumor sizes less than 3 cm in diameter were treated with double-needle clamping cryoablation, while the patients with 3–5 cm tumor sizes were treated with multiple-needle conformal cryoablation. CT was used to monitor the extent of cryoablation during the procedures. At month 1, 3, 6, 12, and 24 post-procedure, enhanced CT scans and/or PET-CT scans were performed to evaluate the impact of the therapy. Results: The average tumor CT values were 32 ± 10 HU and −21 ± 8 HU before and after cryoablation, respectively. The largest diameters of the lesions at month 1, 3, 6, 12, and 24 post-procedure were 2.63 ± 0.56 cm, 1.93 ± 0.51 cm, 1.55 ± 0.39 cm, 1.43 ± 0.40 cm, and 1.38 ± 0.38 cm, respectively, in patients with tumor diameter less than 3 cm, and 3.63 ± 0.39 cm, 2.98 ± 0.31 cm, 2.62 ± 0.32 cm, 2.54 ± 0.34 cm, and 2.56 ± 0.37 cm respectively in patients with the tumor diameters between 3 and 5 cm. At the 24th month, there were 36 cases of complete response (83.7%), 7 cases of partial response (16.3%), and no cases of stable disease or progressive disease. 3 patients died due to multiple metastases. Conclusion: CT-guided percutaneous conformal cryoablation is a safe, effective, and minimally invasive therapeutic method for peripheral lung cancer.

  9. CT-clinical approach to patients with symptoms related to the V, VII, IX-XII cranial nerves and cervical sympathetics

    International Nuclear Information System (INIS)

    Kalovidouris, A.; Mancuso, A.A.; Dillon, W.

    1984-01-01

    Forty-three patients who had signs and symptoms possibly related to the extracranial course of cranial nerves V, VII, IX, X-XII, and the cervical sympathetics were examined prospectively using high resolution CT to obtain images of thin sections during rapid drip infusion of contrast material. Anatomic areas in the scan protocols included the posterior fossa, cavernous and paranasal sinuses, skull base, temporal bone, nasopharynx, parotid gland, tongue base, and neck. Nine of the 23 patients with possible fifth nerve deficits had extracranial structural lesions that explained the symptoms; none of these nine, however, had typical trigeminal neuralgia. Of eight patients with peripheral seventh nerve abnormalities, two had positive findings on scans. Of five patients presenting with referred ear pain, three had carcinoma of the upper aerodigestive tract. The authors' experience suggests that patients at high risk for structural lesions responsible for cranial nerve deficits can be selected by clinical criteria. Protocols for each clinical setting are presented

  10. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  11. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  12. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  13. Recent advances in iterative reconstruction for clinical SPECT/PET and CT.

    Science.gov (United States)

    Hutton, Brian F

    2011-08-01

    Statistical iterative reconstruction is now widely used in clinical practice and has contributed to significant improvement in image quality in recent years. Although primarily used for reconstruction in emission tomography (both single photon emission computed tomography (SPECT) and positron emission tomography (PET)) there is increasing interest in also applying similar algorithms to x-ray computed tomography (CT). There is increasing complexity in the factors that are included in the reconstruction, a demonstration of the versatility of the approach. Research continues with exploration of methods for further improving reconstruction quality with effective correction for various sources of artefact.

  14. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  15. The clinical evaluation of CT and radionuclide examination in renal diseases

    International Nuclear Information System (INIS)

    Kutani, Wataru; Ishida, Hirofumi; Shirakawa, Shigetoshi; Shintaku, Takao; Funaki, Ryo

    1980-01-01

    One hundred and twelve cases of renal diseases were studied by computed tomography (CT) using EMI 5005/12. Of them, 60 were examined by both CT and renal scintigraphy, and comparatively evaluated. The CT units were checked before and after the contrast enhancement. Renal scintigrams were obtained by gamma cameras (PHO/GAMMA HP 6406, PHO/GAMMA LFOV) using 99 M Tc-DMSA. CT was especially useful in diagnosing the renal cysts and the hydronephrosis. Cysts in other organs (liver, spleen and pancreas) were simultaneously ascertained in polycystic diseases. CT was not helpful in diagnosing nephritis and diabetic nephropathy. Floating kidney and horse-shoe kidney were difficult to diagnose with CT. The renal scintigram was the reflection of the renal function, and was relatively more useful than CT in diagnosing horse-shoe kidney, floating kidney and nephritis, while it was not useful for non-functioning kidneys. (author)

  16. Refinement of clinical X-ray computed tomography (CT) scans containing metal implants.

    Science.gov (United States)

    Treece, Graham

    2017-03-01

    X-ray computed tomography (CT) data contains artefacts from many sources, with sufficient prominence to affect diagnostic utility when metal is present in the scans. These artefacts can be reduced, usually by the removal and in-filling of any sinogram data which has been affected by metal, and several such techniques have been proposed. Most of them are prone to introducing new artefacts into the CT data or may take a long time to correct the data. It is the purpose of this paper to introduce a new technique which is fast, yet can effectively remove most artefacts without introducing significant new ones. The new metal artefact reduction technique (RMAR) consists of an iterative refinement of the CT data by alternately forward- and back-projecting the part of the reconstruction near to metal. The forward-projection is corrected by making use of a prior derived from the reconstructed data which is independently estimated for each projection angle, and smoothed using a newly developed Bitonic filter. The new technique is compared with previously published (LI, NMAR, MDT) and commercial (O-MAR, IMAR) alternatives, quantitatively on phantom data, and qualitatively on a selection of clinical scans, mostly of the hip. The phantom data is from two recently published studies, enabling direct comparison with previous results. The results show an increased reduction of artefacts on the four phantom data sets tested. On two of the phantom data sets, RMAR is significantly better (pCT data, RMAR can correct each image in 3-8s, which is more than one hundred times faster than MDT. The new technique is demonstrated to have performance at least as good as MDT, with both out-performing other approaches. However, it is much faster then the latter technique, and shows better preservation of data very close to metal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    OpenAIRE

    Hirschmann, Michael T; Konala, Praveen; Iranpour, Farhad; Kerner, Anna; Rasch, Helmut; Friederich, Niklaus F

    2011-01-01

    Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA). Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization sch...

  18. Radiofrequency Ablation Treatment for Renal Cell Carcinoma: Early Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Hoon; Yoon, Seong Kuk; Cho, Jin Han; Oh, Jong Young; Nam, Kyung Jin; Kwon, Hee Jin; Kim, Su Yeon; Kang, Myong Jin; Choi, Sun Seob; Sung, Gyung Tak [Dong-A University College of Medicine, Busan (Korea, Republic of)

    2008-08-15

    To evaluate the early clinical experience associated with radiofrequency (RF) ablation in patients with renal cell carcinoma (RCC). The RF ablation treatment was performed on 17 tumors from 16 patients (mean age, 60.5 years; range, 43 73 years) with RCC. The treatment indications were localized, solid renal mass, comorbidities, high operation risk, and refusal to perform surgery. All tumors were treated by a percutaneous CT (n = 10), followed by an US-guided (n = 2), laparoscopy-assisted US (n = 2), and an open (n = 2) RF ablation. Furthermore, patients underwent a follow- up CT at one day, one week, one month, three and six months, and then every six months from the onset of treatment. We evaluated the technical success, technical effectiveness, ablation zone, benign periablation enhancement, irregular peripheral enhancement, and complications. All 17 exophytic tumors (mean size, 2.2 cm; range, 1.1 5.0 cm) were completely ablated. Technical success and effectiveness was achieved in all cases and the mean follow-up period was 23.8 months (range, 17 33 months). A local recurrence was not detected in any of the cases; however, five patients developed complications as a result of treatment, including hematuria (n = 2), mild thermal injury of the psoas muscle (n = 1), mild hydronephrosis (n = 1), and fistula formation (n = 1). The RF ablation is an alternative treatment for exophytic RCCs and represents a promising treatment for some patients with small RCCs.

  19. Radiofrequency Ablation Treatment for Renal Cell Carcinoma: Early Clinical Experience

    International Nuclear Information System (INIS)

    Park, Seong Hoon; Yoon, Seong Kuk; Cho, Jin Han; Oh, Jong Young; Nam, Kyung Jin; Kwon, Hee Jin; Kim, Su Yeon; Kang, Myong Jin; Choi, Sun Seob; Sung, Gyung Tak

    2008-01-01

    To evaluate the early clinical experience associated with radiofrequency (RF) ablation in patients with renal cell carcinoma (RCC). The RF ablation treatment was performed on 17 tumors from 16 patients (mean age, 60.5 years; range, 43 73 years) with RCC. The treatment indications were localized, solid renal mass, comorbidities, high operation risk, and refusal to perform surgery. All tumors were treated by a percutaneous CT (n = 10), followed by an US-guided (n = 2), laparoscopy-assisted US (n = 2), and an open (n = 2) RF ablation. Furthermore, patients underwent a follow- up CT at one day, one week, one month, three and six months, and then every six months from the onset of treatment. We evaluated the technical success, technical effectiveness, ablation zone, benign periablation enhancement, irregular peripheral enhancement, and complications. All 17 exophytic tumors (mean size, 2.2 cm; range, 1.1 5.0 cm) were completely ablated. Technical success and effectiveness was achieved in all cases and the mean follow-up period was 23.8 months (range, 17 33 months). A local recurrence was not detected in any of the cases; however, five patients developed complications as a result of treatment, including hematuria (n = 2), mild thermal injury of the psoas muscle (n = 1), mild hydronephrosis (n = 1), and fistula formation (n = 1). The RF ablation is an alternative treatment for exophytic RCCs and represents a promising treatment for some patients with small RCCs

  20. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  1. Case of asymmetrical arthrogryposis. A clinical study and a preliminary report on the value of CT-scanning

    Energy Technology Data Exchange (ETDEWEB)

    Hageman, G.; Vette, J.K.; Willemse, J. (University Hospital, Utrecht (Netherlands))

    1983-01-01

    Following the introduction of the conception that arthrogryposis is a symptom and not a clinical entity, a case of the very rare asymmetric form of neurogenic arthrogryposis is presented. The asymmetry of congenital contractures and weakness is associated with hemihypotrophy. The value of muscular CT-scanning prior to muscle biopsy is demonstrated. Muscular CT-scanning shows the extension of adipose tissue, which has replaced damaged muscles and therby indicates the exact site for muscle biopsy. Since orthopaedic treatment in arthrogryposis can be unrewarding due to severe muscular degeneration, preoperative scanning may provide additional important information on muscular function and thus be of benefit for surgery. The advantage of muscular CT-scanning in other forms of arthrogryposis requires further determination. The differential diagnosis with Werdnig-Hoffmann disease is discussed.

  2. Anatomy and function: PET-CT.

    Science.gov (United States)

    Kajander, Sami; Saraste, Antti; Ukkonen, Heikki; Knuuti, Juhani

    2010-05-01

    CT coronary angiography and perfusion PET form an attractive combination to study coronary artery lesions and their consequences in patients with coronary artery disease. Whereas CT provides non-invasive assessment of coronary lumen and wall, PET perfusion is a reliable method for the evaluation of myocardial flow. CT, although very capable of ruling out significant coronary artery disease, is less than satisfactory in assessing the actual significance of the detected lesions. PET imaging, despite its excellent sensitivity, fails to describe the exact anatomy of the epicardial vessels. By fusing image data from these two modalities, lesions can be accurately correlated with their physiological or anatomical counterparts. Hybrid PET-CT devices, now in wide clinical use, allow such fusion in a one-stop-shop study. Although still seeking its place in clinical scenarios, growing evidence suggests that hybrid PET-CT imaging of coronary anatomy and myocardial perfusion can accurately - and non-invasively - assess the existence and degree of coronary artery disease.

  3. Diagnostic performance of a CT-based scoring system for diagnosis of anastomotic leakage after esophagectomy: comparison with subjective CT assessment

    Energy Technology Data Exchange (ETDEWEB)

    Goense, Lucas; Rossum, Peter S.N. van [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiation Oncology, Utrecht (Netherlands); Stassen, Pauline M.C.; Ruurda, Jelle P.; Hillegersberg, Richard van [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); Wessels, Frank J.; Leeuwen, Maarten S. van [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2017-10-15

    To develop a CT-based prediction score for anastomotic leakage after esophagectomy and compare it to subjective CT interpretation. Consecutive patients who underwent a CT scan for a clinical suspicion of anastomotic leakage after esophagectomy with cervical anastomosis between 2003 and 2014 were analyzed. The CT scans were systematically re-evaluated by two radiologists for the presence of specific CT findings and presence of an anastomotic leak. Also, the original CT interpretations were acquired. These results were compared to patients with and without a clinical confirmed leak. Out of 122 patients that underwent CT for a clinical suspicion of anastomotic leakage; 54 had a confirmed leak. In multivariable analysis, anastomotic leakage was associated with mediastinal fluid (OR = 3.4), esophagogastric wall discontinuity (OR = 4.9), mediastinal air (OR = 6.6), and a fistula (OR = 7.2). Based on these criteria, a prediction score was developed resulting in an area-under-the-curve (AUC) of 0.86, sensitivity of 80%, and specificity of 84%. The original interpretation and the systematic subjective CT assessment by two radiologists resulted in AUCs of 0.68 and 0.75 with sensitivities of 52% and 69%, and specificities of 84% and 82%, respectively. This CT-based score may provide improved diagnostic performance for diagnosis of anastomotic leakage after esophagectomy. (orig.)

  4. Clinical Utility of Iopamidol (Pamiray 370) for Cardiac CT

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Seon, Hyun Ju; Choi, Song; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heong Keun

    2011-01-01

    We evaluated the utility of iopamidol-based nonionic contrast media (Pamiray 370) for cardiac CT, with assessment of its image quality and safety. The study included 100 patients who underwent cardiac CT with Pamiray 370 (experimental group), and 100 patients who underwent cardiac CT with Ultravist 370 (control group). A comparison of the image qualities and degree of vascular contrast enhancement was made between the two groups and evaluated statistically by an independent t-test. Changes in vital signs and adverse events during cardiac CT were evaluated in the experimental group. There were no statistically significant differences in the image quality (image quality score in experimental group vs. control group: 4.26 ± 0.63 vs. 4.24 ± 0.62), and mean attenuation values at the coronary arteries(p > 0.05) between two groups. For the experimental group, 12% experienced adverse events, including mild and transient reactions such as dizziness (7%), nausea (4%), and fatigue (1%). Further, 94% of patients complained of mild to moderate febrile sense just after contrast agent administration, which spontaneously disappeared within 3 minutes without any specific management. For cardiac CT, Pamiray 370 was comparable to the widely-used contrast agent (Ultravist 370) in terms of image quality and safety without any severe adverse reaction.

  5. [Clinical application of high-pitch excretory phase images during dual-source CT urography with stellar photon detector].

    Science.gov (United States)

    Sun, Hao; Xue, Hua-dan; Jin, Zheng-yu; Wang, Xuan; Chen, Yu; He, Yong-lan; Zhang, Da-ming; Zhu, Liang; Wang, Yun; Qi, Bing; Xu, Kai; Wang, Ming

    2014-10-01

    To retrospectively evaluate the clinical feasibility of high-pitch excretory phase images during dual-source CT urography with Stellar photon detector. Totally 100 patients received dual-source CT high-pitch urinary excretory phase scanning with Stellar photon detector [80 kV, ref.92 mAs, CARE Dose 4D and CARE kV, pitch of 3.0, filter back projection reconstruction algorithm (FBP)] (group A). Another 100 patients received dual-source CT high-pitch urinary excretory phase scanning with common detector(100 kV, ref.140 mAs, CARE Dose 4D, pitch of 3.0, FBP) (group B). Quantitative measurement of CT value of urinary segments (Hounsfield units), image noise (Hounsfield units), and effective radiation dose (millisievert) were compared using independent-samples t test between two groups. Urinary system subjective opacification scores were compared using Mann-Whitney U test between two groups. There was no significant difference in subjective opacification score of intrarenal collecting system and ureters between two groups (all P>0.05). The group A images yielded significantly higher CT values of all urinary segments (all P0.05). The effective radiation dose of group A (1.1 mSv) was significantly lower than that of group B (3.79 mSv) (Ppitch low-tube-voltage during excretory phase dual-source CT urography with Stellar photon detector is feasible, with acceptable image noise and lower radiation dose.

  6. Case Report: Hypertensive encephalopathy with CT confirmation in ...

    African Journals Online (AJOL)

    Hypertensive encephalopathy (HE) is a clinical syndrome that occurs infrequently in children and is often underdiagnosed. We review four patients with HE and describe their clinical presentation and radiological findings on computed tomography (CT). Our cases demonstrate typical features on CT and correlate clinically ...

  7. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Lampmann, L.E.H.

    1982-01-01

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  8. Technical note: cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    NARCIS (Netherlands)

    Humbert, L.; Hazrati Marangalou, J.; Del Río Barquero, L.M.; van Lenthe, G.H.; van Rietbergen, B.

    2016-01-01

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical

  9. Pre-clinical medical student experience in a pediatric pulmonary clinic

    Directory of Open Access Journals (Sweden)

    Thomas G. Saba

    2015-11-01

    Full Text Available Objective: Our objective was to evaluate the educational value of introducing pre-clinical medical students to pediatric patients and their families in a subspecialty clinic setting. Methods: First- and second-year medical students at the University of Michigan seeking clinical experience outside of the classroom attended an outpatient pediatric pulmonary clinic. Evaluation of the experience consisted of pre- and post-clinic student surveys and post-clinic parent surveys with statements employing a four-point Likert scale as well as open-ended questions. Results: Twenty-eight first-year students, 6 second-year students, and 33 parents participated in the study. Post-clinic statement scores significantly increased for statements addressing empathic attitudes, confidence communicating with children and families, comfort in the clinical environment, and social awareness. Scores did not change for statements addressing motivation, a sense of team membership, or confidence with career goals. Students achieved their goals of gaining experience interacting with patients, learning about pulmonary diseases, and observing clinic workflow. Parents felt that they contributed to student education and were not inconvenienced. Conclusions: Students identified several educational benefits of exposure to a single pediatric pulmonary clinic. Patients and families were not inconvenienced by the participation of a student. Additional studies are warranted to further investigate the value of this model of pre-clinical medical student exposure to subspecialty pediatrics.

  10. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  11. Restoration of Thickness, Density, and Volume for Highly Blurred Thin Cortical Bones in Clinical CT Images.

    Science.gov (United States)

    Pakdel, Amirreza; Hardisty, Michael; Fialkov, Jeffrey; Whyne, Cari

    2016-11-01

    In clinical CT images containing thin osseous structures, accurate definition of the geometry and density is limited by the scanner's resolution and radiation dose. This study presents and validates a practical methodology for restoring information about thin bone structure by volumetric deblurring of images. The methodology involves 2 steps: a phantom-free, post-reconstruction estimation of the 3D point spread function (PSF) from CT data sets, followed by iterative deconvolution using the PSF estimate. Performance of 5 iterative deconvolution algorithms, blind, Richardson-Lucy (standard, plus Total Variation versions), modified residual norm steepest descent (MRNSD), and Conjugate Gradient Least-Squares were evaluated using CT scans of synthetic cortical bone phantoms. The MRNSD algorithm resulted in the highest relative deblurring performance as assessed by a cortical bone thickness error (0.18 mm) and intensity error (150 HU), and was subsequently applied on a CT image of a cadaveric skull. Performance was compared against micro-CT images of the excised thin cortical bone samples from the skull (average thickness 1.08 ± 0.77 mm). Error in quantitative measurements made from the deblurred images was reduced 82% (p < 0.01) for cortical thickness and 55% (p < 0.01) for bone mineral mass. These results demonstrate a significant restoration of geometrical and radiological density information derived for thin osseous features.

  12. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  13. [Liver trauma due to penetrating lesions: miscellanea, personal case series, clinical and CT findings].

    Science.gov (United States)

    Salzano, A; Nocera, V; De Rosa, A; Rossi, E; Carbone, M; Gatta, G; Vitale, L; Vigliotti, A

    2000-12-01

    Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. We will report the clinical and radiological findings of our personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. We will also try to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years we retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different causes. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the mid-chest for accurate assessment of diaphragm and lung bases and to exclude associated pleuropulmonary damage. Penetrating liver wounds were caused by firearms in 70% of cases, by stabbing in 12% and, in the extant 18%, by other causes such as home accidents, road and work traumas, and liver biopsy. In our series, the liver was most frequently involved, especially by firearms wounds; in our 16 cases the most frequent injuries were hemorrhagic tears. We found bullets in the liver in 6 cases. In one case of home accident the patient wounded himself while slicing bread with a long knife, which cut into the anterior abdominal wall and tore the anterior liver capsule, as seen at CTA. Penetrating wounds to liver and abdomen are less frequent than those to the chest. In the past decade the use of CT has changed the diagnostic and therapeutic approach to such injuries completely, decreasing the resort to explorative laparotomy and hepatorrhaphy. Indeed, CT provides a clear picture of the extent and

  14. Clinical applications of the superior epigastric artery perforator (SEAP) flap: anatomical studies and preoperative perforator mapping with multidetector CT.

    Science.gov (United States)

    Hamdi, Moustapha; Van Landuyt, Koenraad; Ulens, Sara; Van Hedent, Eddy; Roche, Nathalie; Monstrey, Stan

    2009-09-01

    Pedicled superior epigastric artery perforator (SEAP) flaps can be raised to cover challenging thoracic defects. We present an anatomical study based on multidetector computerized tomography (MDCT) scan findings of the SEA perforators in addition to the first reported clinical series of SEAP flaps in anterior chest wall reconstruction. (a) In the CT scan study, images of a group of 20 patients who underwent MDCT scan analysis were used to visualise bilaterally the location of musculocutaneous SEAP. X- and Y-axes were used as landmarks to localise the perforators. The X-axis is a horizontal line at the junction of sternum and xyphoid (JCX) and the Y-axis is at the midline. (b) In the clinical study, seven pedicled SEAP flaps were performed in another group of patients. MDCT images revealed totally 157 perforators with a mean of 7.85 perforators per patient. The dominant perforators (137 perforators) were mainly localised in an area between 1.5 and 6.5 cm from the X-axis on both sides and between 3 and 16 cm below the Y-axis. The calibre of these dominant perforators was judged as 'good' to 'very good' in 82.5% of the cases. The average dimension of the flap was 21.7x6.7 cm. All flaps were based on one perforator. Mean harvesting time was 110 min. There were no flap losses. Minor tip necrosis occurred in two flaps. One of them was treated with excision and primary closure. Our clinical experience indicates that the SEAP flap provides a novel and useful approach for reconstruction of anterior chest wall defects. CT-based imaging allows for anatomical assessment of the perforators of the superior epigastric artery (SEA).

  15. A prototype table-top inverse-geometry volumetric CT system

    International Nuclear Information System (INIS)

    Schmidt, Taly Gilat; Star-Lack, Josh; Bennett, N. Robert; Mazin, Samuel R.; Solomon, Edward G.; Fahrig, Rebecca; Pelc, Norbert J.

    2006-01-01

    A table-top volumetric CT system has been implemented that is able to image a 5-cm-thick volume in one circular scan with no cone-beam artifacts. The prototype inverse-geometry CT (IGCT) scanner consists of a large-area, scanned x-ray source and a detector array that is smaller in the transverse direction. The IGCT geometry provides sufficient volumetric sampling because the source and detector have the same axial, or slice direction, extent. This paper describes the implementation of the table-top IGCT scanner, which is based on the NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) and an investigation of the system performance. The alignment and flat-field calibration procedures are described, along with a summary of the reconstruction algorithm. The resolution and noise performance of the prototype IGCT system are studied through experiments and further supported by analytical predictions and simulations. To study the presence of cone-beam artifacts, a ''Defrise'' phantom was scanned on both the prototype IGCT scanner and a micro CT system with a ±5 deg.cone angle for a 4.5-cm volume thickness. Images of inner ear specimens are presented and compared to those from clinical CT systems. Results showed that the prototype IGCT system has a 0.25-mm isotropic resolution and that noise comparable to that from a clinical scanner with equivalent spatial resolution is achievable. The measured MTF and noise values agreed reasonably well with theoretical predictions and computer simulations. The IGCT system was able to faithfully reconstruct the laminated pattern of the Defrise phantom while the micro CT system suffered severe cone-beam artifacts for the same object. The inner ear acquisition verified that the IGCT system can image a complex anatomical object, and the resulting images exhibited more high-resolution details than the clinical CT acquisition. Overall, the successful implementation of the prototype system supports the IGCT concept for

  16. Clinical application of CT-guided radiofrequency ablation for the treatment of metastatic bone neoplasms

    International Nuclear Information System (INIS)

    Gong Ju; Lu Zhijun; Wang Zhongmin; Zhang Liyun; Zheng Yunfeng; Chen Kemin

    2009-01-01

    Objective: To investigate the clinical efficacy of CT-guided radiofrequency ablation (RFA) for the treatment of metastatic bone neoplasms. Methods: Under intravenous aneaesthesia, CT- guided RFA was performed in 20 patients with metastatic bone tumor. The degree of pain was evaluated at 24 hours, 3 and 6 months after the operation by brief pain inventory (BPI). Results: All patients were followed up for 6 months and survived so far. The average peak pain score before the operation was 8.1 (6-10), which decreased significantly to 6.1, 4.6, 3.3 and 3.0 at 24 hours, 1, 3 and 6 months after the operation respectively (P<0.001). The mean pain score before the operation was 6.3, which decreased significantly to 4.0, 2.3, 2.13 and 1.9 at 24 hours, 1, 3 and 6 months after the operation respectively (P<0.001). After RFA treatment, the KPS scores of all patients increased while the CT values of the bone lesions decreased. No major complications occurred both during and after the operation. One patient with vertebral lamina destruction suffered from lower limb hypoesthesia after RFA procedure, and the lower limb sensation was restored within 48 hours after the injection of prednisone was employed. Conclusion: CT-guided radiofisequency ablation is a safe, effective, minimally-invasive and up-to-date technique for the treatment of metastatic bone neoplasms with excellent anti-pain effect, its short-term response is sure and reliable. (authors)

  17. The role of key image notes in CT imaging study interpretation.

    Science.gov (United States)

    Fan, Shu-Feng; Xu, Zhe; He, Hai-Qing; Ding, Jian-Rong; Teng, Gao-Jun

    2011-04-01

    The objective of the study was to investigate the clinical effects of CT key image notes (KIN) in the interpretation of a CT image study. All experiments were approved by the ethics committee of the local district. Six experienced radiologists were equally divided into routine reporting (RR) group and KIN reporting (KIN) group. CT scans of each 100 consecutive cases before and after using KIN technique were randomly selected, and the reports were made by group RR and KIN, respectively. All the reports were again reviewed 3 months later by both groups. All the results with using or not using KIN were interpreted and reinterpreted after 3 months by six clinicians, who were experienced in picture archiving and communication system (PACS) applications and were equally divided into the clinical routine report group and the clinical KIN report group, respectively. The results were statistically analyzed; the time used in making a report, the re-reading time 3 months later, and the consistency of imaging interpretation were determined and compared between groups. After using KIN technique, the time used in making a report was significantly increased (8.77 ± 5.27 vs. 10.53 ± 5.71 min, P < 0.05), the re-reading time was decreased (5.23 ± 2.54 vs. 4.99 ± 1.70 min, P < 0.05), the clinical interpretation and reinterpretation time after 3 months were decreased, and the consistency of the interpretation, reinterpretation between different doctors in different time was markedly improved (P < 0.01). CT report with KIN technique in PACS can significantly improve the consistency of the interpretation and efficiency in routine clinical work.

  18. Case of clinical Reye syndrome presenting characteristic CT changes

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Tamaki; Sai, Hoshun; Morikawa, Yuji; Mizuta, Ryuzo [Kyoto Second Red Cross Hospital (Japan); Okuno, Takehiko

    1984-05-01

    A 9-month-old male infant was admitted to our hospital on the second day of cold like syndrome because of high fever, convulsion, coma, and decerebrate rigidity. Serum GOT, GPT, LDH, and CPK were markedly elevated. Serum ammonia was slightly increased, and hypoglycemia was present. The cerebrospinal fluid showed no pleocytosis, normal sugar content, but increased protein. Thus we made a diagnosis of clinical Reye syndrome according to the criteria by Yamashita, et al. A CT on the day of admission showed symmetrical low-density areas in the posterior fossa and the regions of thalamus. Ringed enhancements were seen around the areas of low density in the thalamus on the twenty-second hospital day. We consider that these lesions may represent the infarction due to obstruction of the thalamoperforant arteries caused by cerebral edema in the early stage of the disease.

  19. Detection of low-grade prosthetic joint infections using {sup 99m}Tc-antigranulocyte SPECT/CT: initial clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus [University of Munich, Department of Nuclear Medicine, Munich (Germany); Feist, Markus; Mueller, Peter Ernst [University of Munich, Department of Orthopedic Medicine, Munich (Germany)

    2010-09-15

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using {sup 99m}Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  20. CT of submandibular gland sialolithiasis

    International Nuclear Information System (INIS)

    Avrahami, E.; Englender, M.; Chen, E.; Shabtay, D.; Katz, R.; Harell, M.

    1996-01-01

    We emphasise the importance of high-resolution CT with reconstruction in the demonstration of submandibular gland (SMG) sialolithiasis and its role in monitoring treatment. We studied 76 patients with swollen and tender SMG, some with fever. They underwent conventional radiography, sonography (US) and high-resolution CT with reconstructions. Conventional radiographs demonstrated single stones in 29 patients. Axial CT, before reconstructions, demonstrated single stones in 63 patients and multiple stones in another 5. Following CT reconstructions, multiple stones were demonstrated in 37 patients. On US stones were diagnosed in only 33 patients, and multiple stones in only 1. All 68 patients with stones shown on imaging and 2 without stones underwent surgery, with good clinical results. Total removal of the SMG and its duct was performed in patients with multiple stones, chronic inflammatory changes in the SMG, or a solitary stone in the SMG or deep in the duct. A small incision for removal of a solitary stone in the distal aspects of Wharton's duct was performed in 15 patients, with excellent clinical results. Another 14 patients with multiple salivary glad stones, diagnosed on CT reconstructions, did not improve following this procedure and needed further surgery; clinical improvement occurred following excision of the SMG and Wharton's duct. Histological examination in all of these confirmed the presence of additional stones. Conservative anti-inflammatory treatment was recommended for 6 patients in whom CT reconstructions did not demonstrate stones. (orig.)