Sample records for ct scan image

  1. CT scan of the brain (image)

    Science.gov (United States)

    ... CAT scan (computed tomography) is a much more sensitive imaging technique than x-ray, allowing high definition not only of the bony structures, but of the soft tissues. Clear images of organs such as the brain, muscles, joint structures, veins ...

  2. Hybrid detection of lung nodules on CT scan images

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Lin; Tan, Yongqiang; Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-09-15

    Purpose: The diversity of lung nodules poses difficulty for the current computer-aided diagnostic (CAD) schemes for lung nodule detection on computed tomography (CT) scan images, especially in large-scale CT screening studies. We proposed a novel CAD scheme based on a hybrid method to address the challenges of detection in diverse lung nodules. Methods: The hybrid method proposed in this paper integrates several existing and widely used algorithms in the field of nodule detection, including morphological operation, dot-enhancement based on Hessian matrix, fuzzy connectedness segmentation, local density maximum algorithm, geodesic distance map, and regression tree classification. All of the adopted algorithms were organized into tree structures with multi-nodes. Each node in the tree structure aimed to deal with one type of lung nodule. Results: The method has been evaluated on 294 CT scans from the Lung Image Database Consortium (LIDC) dataset. The CT scans were randomly divided into two independent subsets: a training set (196 scans) and a test set (98 scans). In total, the 294 CT scans contained 631 lung nodules, which were annotated by at least two radiologists participating in the LIDC project. The sensitivity and false positive per scan for the training set were 87% and 2.61%. The sensitivity and false positive per scan for the testing set were 85.2% and 3.13%. Conclusions: The proposed hybrid method yielded high performance on the evaluation dataset and exhibits advantages over existing CAD schemes. We believe that the present method would be useful for a wide variety of CT imaging protocols used in both routine diagnosis and screening studies.

  3. Head CT scan

    Science.gov (United States)

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... hold your breath for short periods. A complete scan usually take only 30 seconds to a few ...

  4. Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner

    Science.gov (United States)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.

    2006-03-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.

  5. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    Science.gov (United States)

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  6. Pancreas tumor model in rabbit imaged by perfusion CT scans

    Science.gov (United States)

    Gunn, Jason; Tichauer, Kenneth; Moodie, Karen; Kane, Susan; Hoopes, Jack; Stewart, Errol E.; Hadway, Jennifer; Lee, Ting-Yim; Pereira, Stephen P.; Pogue, Brian W.

    2013-03-01

    The goal of this work was to develop and validate a pancreas tumor animal model to investigate the relationship between photodynamic therapy (PDT) effectiveness and photosensitizer drug delivery. More specifically, this work lays the foundation for investigating the utility of dynamic contrast enhanced blood perfusion imaging to be used to inform subsequent PDT. A VX2 carcinoma rabbit cell line was grown in the tail of the pancreas of three New Zealand White rabbits and approximately 3-4 weeks after implantation the rabbits were imaged on a CT scanner using a contrast enhanced perfusion protocol, providing parametric maps of blood flow, blood volume, mean transit time, and vascular permeability surface area product.

  7. Open source deformable image registration system for treatment planning and recurrence CT scans

    DEFF Research Database (Denmark)

    Zukauskaite, Ruta; Brink, Carsten; Hansen, Christian Rønn

    2016-01-01

    manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. METHODS: pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR...... on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p elastix in HNSCC on planning and recurrence CT scans is feasible...

  8. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    Science.gov (United States)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  9. Lumbar spine CT scan

    Science.gov (United States)

    CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... your breath for short periods of time. The scan should take only 10 to 15 minutes.

  10. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  11. Subperiosteal chondroma. Diagnostic value of CT scan imaging in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lerais, J.M.; Auquier, F.; Baudrillard, J.C.; Durot, J.F.; Laugareil, P.; Wallays, C.; Lefort, G.; Daoud, S.; Gaillard, D.

    1988-01-01

    Results of CT scan exploration are reported in two cases of subperiosteal chondroma, one in a 4 year old child affecting the anterior tibial tuberosity the other in a 9 year old child involving the upper end of humerus. Data from CT scan imaging were undoubtedly superior to those of conventional radiography and appear to be characteristic of this benign cartilaginous tumor, greatly facilitating correlation between clinical, radiological and pathologic findings. The scanner should allow certain situations to be dedramatized and the surgical attitude adapted when the functional prognosis is involved.

  12. Evaluation of the image quality of chest CT scans: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Martins N, P. I.; Prata M, A., E-mail: priscillainglid@gmail.com [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) is considered one of the most important methods of medical imaging employed nowadays, due to its non-invasiveness and the high quality of the images it is able to generate. However, the diagnostic radiation dose received by an individual over the year often exceeds the dose received on account of background radiation. Therefore, it is important to know and to control the dose distribution in the patient by varying the image acquisition parameters. The aim of this study is to evaluate the variation of the image quality of chest CT scans performed by two phantoms. In this paper, a cylindrical Polymethyl Methacrylate (PMMA) chest phantom was used and a second PMMA phantom has been developed with the same volume but an oblong shape, based on the actual dimensions of a male human thorax, in the axillary region. Ten-centimeter scans of the central area of each phantom were performed by a 16-channel Toshiba CT scanner, model Alexion. The scanning protocol employed was the radiology service protocol for chest scans. The noise survey was conducted within the image of the center slice, in five regions: one central and four peripheral areas close to the edge of the object (anterior, posterior, left and right). The recorded values showed that the oblong phantom, with a shape that is more similar to the actual human chest, has a considerably smaller noise, especially in the anterior, posterior and central regions. (Author)

  13. Lumbar spine joint synovial cysts of intraspinal development. CT scan imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vallee, C.; Chevrot, A.; Benhamouda, M. and others

    CT scan imaging findings are described in 22 patients with lumbar spine joint synovial cysts, of intraspinal development, provoking sciatica or lumbosciatica from nerve compression in spinal canal. Diagnosis was suggested by a mass at the posterior joint level, of variable density, sometimes with peripheral calcification, presenting a vacuum appearance on occasions, and with enhanced image with contrast. Differential diagnosis is from excluded hernia and postoperative fibrosis. Posterior intra-articular arthrography can confirm diagnosis and allow treatment with prolonged action corticoid infiltrations.

  14. Interapophyseal joint synovial cyst of lumbar spine. CT scan and MR imaging correlation in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Granat, O.; Jeanbourquin,D.; Perfettini, C.; Pernot, P.; Ducolombier, A.; Cosnard, G.

    1987-05-01

    Two patients presenting with L5 radiculagia were investigated by CT scan imaging. The origin of the pain was determined with certitude as arising from intraspinal development of an interapophyseal synovial cyst. Examination of the two cases by MR imaging provided conflicting results: in one patient images obtained by MR were not contributive and the synovial cyst would probably have been missed while in the other patient images were specific and very sensitive for diagnosis of interapophyseal synovial lesions. Treatment was surgical in both cases.

  15. Cardiac CT Scan

    Science.gov (United States)

    ... combine these pictures to create a three-dimensional (3D) model of the whole heart. This imaging test ... findings from earlier chest x rays. Different CT scanners are used for different purposes. A multidetector CT ...

  16. Investigation of the potential causes of partial scan artifacts in dynamic CT myocardial perfusion imaging

    Science.gov (United States)

    Tao, Yinghua; Speidel, Michael; Szczykutowicz, Timothy; Chen, Guang-Hong

    2014-03-01

    In recent years, there have been several findings regarding CT number variations (partial scan artifact or PSA) across time in dynamic myocardial perfusion studies with short scan gated reconstruction. These variations are correlated with the view angle range corresponding to the short scan acquisition for a given cardiac phase, which can vary from one cardiac cycle to another due to the asynchrony between heart rate and gantry rotation speed. In this study, we investigate several potential causes of PSA, including noise, beam hardening and scatter, using numerical simulations. In addition, we investigate partial scan artifact in a single source 64-slice diagnostic CT scanner in vivo data sets, and report its effect on perfusion analysis. Results indicated that among all three factors investigated, scatter can cause obvious partial scan artifact in dynamic myocardial perfusion imaging. Further, scatter is a low frequency phenomenon and is not heavily dependent on the changing contrasts, as both the frequency method and the virtual scan method are effective in reducing partial scan artifact. However, PSA does not necessarily lead to different blood volume maps compared to the full scan, because these maps are usually generated with a curve fitting procedure.

  17. Axial segmentation of lungs CT scan images using canny method and morphological operation

    Science.gov (United States)

    Noviana, Rina; Febriani, Rasal, Isram; Lubis, Eva Utari Cintamurni

    2017-08-01

    Segmentation is a very important topic in digital image process. It is found simply in varied fields of image analysis, particularly within the medical imaging field. Axial segmentation of lungs CT scan is beneficial in designation of abnormalities and surgery planning. It will do to ascertain every section within the lungs. The results of the segmentation are accustomed discover the presence of nodules. The method which utilized in this analysis are image cropping, image binarization, Canny edge detection and morphological operation. Image cropping is done so as to separate the lungs areas, that is the region of interest. Binarization method generates a binary image that has 2 values with grey level, that is black and white (ROI), from another space of lungs CT scan image. Canny method used for the edge detection. Morphological operation is applied to smoothing the lungs edge. The segmentation methodology shows an honest result. It obtains an awfully smooth edge. Moreover, the image background can also be removed in order to get the main focus, the lungs.

  18. Automated Detection of Healthy and Diseased Aortae from Images Obtained by Contrast-Enhanced CT Scan

    Directory of Open Access Journals (Sweden)

    Michael Gayhart

    2013-01-01

    Full Text Available Purpose. We developed the next stage of our computer assisted diagnosis (CAD system to aid radiologists in evaluating CT images for aortic disease by removing innocuous images and highlighting signs of aortic disease. Materials and Methods. Segmented data of patient’s contrast-enhanced CT scan was analyzed for aortic dissection and penetrating aortic ulcer (PAU. Aortic dissection was detected by checking for an abnormal shape of the aorta using edge oriented methods. PAU was recognized through abnormally high intensities with interest point operators. Results. The aortic dissection detection process had a sensitivity of 0.8218 and a specificity of 0.9907. The PAU detection process scored a sensitivity of 0.7587 and a specificity of 0.9700. Conclusion. The aortic dissection detection process and the PAU detection process were successful in removing innocuous images, but additional methods are necessary for improving recognition of images with aortic disease.

  19. CT scan of choristoma

    Energy Technology Data Exchange (ETDEWEB)

    Moriki, A.; Morimoto, M.; Sada, Y.; Kurisaka, M.; Mori, K.

    1987-02-01

    Choristoma is a rare tumor that occurs in the pituitary gland. The case presented here is a 44-year-old male. A plain CT scan demonstrated a slight high-density mass near the posterior clinoid of the sella turcica, while a moderate and homogeneous enhancing effect and a clear borderline were shown by an enhanced CT scan. A cornal CT scan study showed that the tumor extended from the intrasellar to the suprasellar region. The diagnosis of choristoma was made by means of histology.

  20. National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chung-Jung Lin

    Full Text Available The purpose of the present study was to evaluate the influence of different variables on radiation dose and image quality based on a national database.Taiwan's Ministry of Health and Welfare requested all radiology departments to complete a questionnaire for each of their CT scanners. Information gathered included all scanning parameters for CT head scans. For the present analysis, CT machines were divided into three subgroups: single slice CT (Group A; multi-detector CT (MDCT with 2-64 slices (Group B; and MDCT with more than 64 slices (Group C. Correlations between computed tomography dose index (CTDI and signal-to-noise ratio (SNR with cumulated tube rotation number (CTW(n and cumulated tube rotation time (CTW(s, and sub group analyses of CTDI and SNR across the three groups were performed.CTDI values demonstrated a weak correlation (r = 0.33 with CTW(n in Group A. SNR values demonstrated a weak negative correlation (r = -0.46 with CTW(n in Group C. MDCT with higher slice numbers used more tube potential resulting in higher effective doses. There were both significantly lower CTDI and SNR values in helical mode than in axial mode in Group B, but not Group C.CTW(n and CTW(s did not influence radiation output. Helical mode is more often used in MDCT and results in both lower CTDI and SNR compared to axial mode in MDCT with less than 64 slices.

  1. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  2. Cervical spine CT scan

    Science.gov (United States)

    ... defects of the cervical spine Bone problems Fracture Osteoarthritis Disc herniation Risks Risks of CT scans include: ... Ma, MD, Assistant Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  3. Evaluating 3D registration of CT-scan images using crest lines

    Science.gov (United States)

    Ayache, Nicholas; Gueziec, Andre P.; Thirion, Jean-Philippe; Gourdon, A.; Knoplioch, Jerome

    1993-06-01

    We consider the issue of matching 3D objects extracted from medical images. We show that crest lines computed on the object surfaces correspond to meaningful anatomical features, and that they are stable with respect to rigid transformations. We present the current chain of algorithmic modules which automatically extract the major crest lines in 3D CT-Scan images, and then use differential invariants on these lines to register together the 3D images with a high precision. The extraction of the crest lines is done by computing up to third order derivatives of the image intensity function with appropriate 3D filtering of the volumetric images, and by the 'marching lines' algorithm. The recovered lines are then approximated by splines curves, to compute at each point a number of differential invariants. Matching is finally performed by a new geometric hashing method. The whole chain is now completely automatic, and provides extremely robust and accurate results, even in the presence of severe occlusions. In this paper, we briefly describe the whole chain of processes, already presented to evaluate the accuracy of the approach on a couple of CT-scan images of a skull containing external markers.

  4. Reduction of Cone-Beam CT scan time without compromising the accuracy of the image registration in IGRT

    DEFF Research Database (Denmark)

    Westberg, Jonas; Jensen, Henrik R; Bertelsen, Anders;

    2010-01-01

    In modern radiotherapy accelerators are equipped with 3D cone-beam CT (CBCT) which is used to verify patient position before treatment. The verification is based on an image registration between the CBCT acquired just before treatment and the CT scan made for the treatment planning. The purpose...... of this study is to minimise the scan time of the CBCT without compromising the accuracy of the image registration in IGRT....

  5. 3D segmentation of abdominal aorta from CT-scan and MR images.

    Science.gov (United States)

    Duquette, Anthony Adam; Jodoin, Pierre-Marc; Bouchot, Olivier; Lalande, Alain

    2012-06-01

    We designed a generic method for segmenting the aneurismal sac of an abdominal aortic aneurysm (AAA) both from multi-slice MR and CT-scan examinations. It is a semi-automatic method requiring little human intervention and based on graph cut theory to segment the lumen interface and the aortic wall of AAAs. Our segmentation method works independently on MRI and CT-scan volumes and has been tested on a 44 patient dataset and 10 synthetic images. Segmentation and maximum diameter estimation were compared to manual tracing from 4 experts. An inter-observer study was performed in order to measure the variability range of a human observer. Based on three metrics (the maximum aortic diameter, the volume overlap and the Hausdorff distance) the variability of the results obtained by our method is shown to be similar to that of a human operator, both for the lumen interface and the aortic wall. As will be shown, the average distance obtained with our method is less than one standard deviation away from each expert, both for healthy subjects and for patients with AAA. Our semi-automatic method provides reliable contours of the abdominal aorta from CT-scan or MRI, allowing rapid and reproducible evaluations of AAA.

  6. Improved image quality and radiation dose reduction in liver dynamic CT scan with the protocol change

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yu Jin; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5-24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120 kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100 kVp, apply SAFIRE strength 0-5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120 kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100 kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100 kVp than 120 kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality

  7. Self-directed learning modules of CT scan images to improve students' perception of gross anatomy.

    Science.gov (United States)

    Kumar, Pananghat Achutha; Jothi, Ramakrishnan; Mathivanan, Dharmalingam

    2016-01-01

    A contemporary anatomy curriculum that aims to be clinically relevant requires medical students to be introduced to radiological anatomy in the preclinical years. Ideally, the curriculum should also support self-directed learning, a habit best instilled early. Based on these educational requirements, we designed an interesting and clinically-meaningful program of self-learning modules in radiological anatomy to augment students' learning of gross anatomy. The program is guided by current theories of learning, which emphasize an individualized learning pace for students. This program uses enlarged computerized tomography (CT) scan images and associated resource materials. Scans are posted on the first day of the week in a public area for students to review on their own time. On the second day penciled outlines of important structures are provided to help students identify structures, and students are encouraged to discuss the images with faculty. On the last day of the week the identity of the structures are revealed to students. An open-ended questionnaire used to evaluate the program revealed that 95.5% of students used the program and a great majority recommended the program should be continued for future students. The present program enhances learning of gross anatomical relations through having students use visual clues in logically interpreting unlabeled CT scans in an organized and sequential way. The program promotes self-directed learning. In addition to its use with preclinical students, the modules might also help students in the clinical phase of the curriculum bolster their knowledge of spatial anatomy.

  8. Image reconstruction for view-limited x-ray CT in baggage scanning

    Science.gov (United States)

    Mandava, Sagar; Coccarelli, David; Greenberg, Joel A.; Gehm, Michael E.; Ashok, Amit; Bilgin, Ali

    2017-05-01

    X-ray CT based baggage scanners are widely used in security applications. Recently, there has been increased interest in view-limited systems which can improve the scanning throughput while maintaining the threat detection performance. However as very few view angles are acquired in these systems, the image reconstruction problem is challenging. Standard reconstruction algorithms such as the filtered backprojection create strong artifacts when working with view-limited data. In this work, we study the performance of a variety of reconstruction algorithms for both single and multi-energy view-limited systems.

  9. Chest CT Scan

    Science.gov (United States)

    ... can combine these pictures to create three-dimensional (3D) models to help show the size, shape, and ... a medical imaging facility or hospital. The CT scanner is a large, tunnel-like machine that has ...

  10. Open source deformable image registration system for treatment planning and recurrence CT scans : Validation in the head and neck region.

    Science.gov (United States)

    Zukauskaite, Ruta; Brink, Carsten; Hansen, Christian Rønn; Bertelsen, Anders; Johansen, Jørgen; Grau, Cai; Eriksen, Jesper Grau

    2016-08-01

    Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images.

  11. Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Park, Hyok; Kim, Dong Ook; Jeong, Hai Jo; Kim, Hee Joung; Yoo, Sun Kook; Kim, Yong Oock; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate the quantitative accuracy of three-dimensional (3D) images by mean of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0 (Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. 11 line items in Conventional 3 mm, 8 in Helical 3 mm, 11 in Conventional 5 mm, 10 in Helical 5 mm, 5 in Conventional 7 mm and 9 in Helical 7 mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2 mm in 19 line items of Conventional 3 mm. 20 of Helical 3 mm, 15 of Conventional 5 mm, 18 of Helical 5 mm, 11 of Conventional 7 mm and 16 of Helical 7 mm. Considering image quality and patient's exposure time, scanning protocol of Helical 5 mm is recommended for 3D image analysis of the skull in CT.

  12. Multislice CT scans in patients on extracorporeal membrane oxygenation: Emphasis on hemodynamic changes and imaging pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Kao Lang; Wang, Yu Feng; Chang, Yeun Chung; Huang, Shu Chien; Chen, Shyh Jye; Chang, Chin Chen [National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei (China); Tsang, Yuk Ming [Dept. of Medical Imaging, Far Eastern Memorial Hospital, New Taipei City (China)

    2014-06-15

    This pictorial review provides the principles of extracorporeal membrane oxygenation (ECMO) support and associated CT imaging features with emphasis on the hemodynamic changes and possible imaging pitfalls encountered. It is important that radiologists in ECMO centers apply well-designed imaging protocols and familiarize themselves with post-contrast CT imaging findings in patients on ECMO.

  13. High Dose MicroCT Does Not Contribute Toward Improved MicroPET/CT Image Quantitative Accuracy and Can Limit Longitudinal Scanning of Small Animals

    Directory of Open Access Journals (Sweden)

    Wendy A. McDougald

    2017-10-01

    Full Text Available Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1 to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2 to evaluate the absorbed dose associated with varying CT parameters.Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA software implemented by Mediso. Measured Hounsfield Unit (HU in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC, uniformity and quantitative bias were also measured.Results: Only less than 2 and 1% of CT acquisition protocols yielded water HU values < −80 and air HU values < −840, respectively. Four out of 11 CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration.Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed toward improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  14. Static Myocardial Perfusion Imaging using denoised dynamic Rb-82 PET/CT scans

    DEFF Research Database (Denmark)

    Petersen, Maiken N.M.; Hoff, Camilla; Harms, Hans

    Introduction: Relative and absolute measures of myocardial perfusion are derived from a single 82Rb PET/CT scan. However, images are inherently noising due to the short half-life of 82Rb. We have previously shown that denoising techniques can be applied to dynamic 82Rb series with excellent....... Administered 82Rb dose was 1110 MBq. Denoising using HYPR-LR or Hotelling 3D algorithms was performed as post-processing on the dynamic images series. Static series were created by summing frames from 2.5-5 min. The image data was analysed in QPET (Cedars-Sinai). Relative segmental perfusion (normalized...... and Bland-Altman analysis. Results: For HYPR-LR, a good correlation was found for relative segmental perfusion for both stress (y=1.007x+0.313, R2=0.98) and rest (y=1.007x+ 0.421, R2=0.96) scans with negative bias of -0.79±1.44 and -0.90±1.63, respectively. Correlations for SSS (R2=0.94), SRS (R2=0.92), SDS...

  15. SEGMENTATION OF CT SCAN LUMBAR SPINE IMAGE USING MEDIAN FILTER AND CANNY EDGE DETECTION ALGORITHM

    Directory of Open Access Journals (Sweden)

    E.Punarselvam

    2013-09-01

    Full Text Available The lumbar vertebrae are the largest segments of the movable part of the vertebral column, they are elected L1 to L5, starting at the top. The spinal column, more commonly called the backbone, is made up primarily of vertebrae discs, and the spinal cord. Acting as a communication conduit for the brain, signals are transmitted and received through the spinal cord. It is otherwise known as vertebralcolumn consists of 24 separate bony vertebrae together with 5 fused vertebrae, it is the unique interaction between the solid and fluid components that provides the disc strength and flexibility required to bear loading of the lumbar spine. In this work the Segmentation of Spine Image using Median Filter and Canny Edge Detection Algorithm between lumbar spine CT scan spine disc image. The result shows thatthe canny edge detection algorithm produced better result when compared other edge detection algorithm. Finding the correct boundary in a noisy image of spine disc is still a difficult one. To find outabsolute edges from noisy images, the comparative result can be verified and validated with the standard medical values. The result shows that the canny edge detection algorithm performs well and produced a solution very nearer to the optimal solution. This method is vigorous for all kinds of noisy images.

  16. Automatic transperineal ultrasound probe positioning based on CT scan for image guided radiotherapy

    Science.gov (United States)

    Camps, S. M.; Verhaegen, F.; Paiva Fonesca, G.; de With, P. H. N.; Fontanarosa, D.

    2017-03-01

    Image interpretation is crucial during ultrasound image acquisition. A skilled operator is typically needed to verify if the correct anatomical structures are all visualized and with sufficient quality. The need for this operator is one of the major reasons why presently ultrasound is not widely used in radiotherapy workflows. To solve this issue, we introduce an algorithm that uses anatomical information derived from a CT scan to automatically provide the operator with a patient-specific ultrasound probe setup. The first application we investigated, for its relevance to radiotherapy, is 4D transperineal ultrasound image acquisition for prostate cancer patients. As initial test, the algorithm was applied on a CIRS multi-modality pelvic phantom. Probe setups were calculated in order to allow visualization of the prostate and adjacent edges of bladder and rectum, as clinically required. Five of the proposed setups were reproduced using a precision robotic arm and ultrasound volumes were acquired. A gel-filled probe cover was used to ensure proper acoustic coupling, while taking into account possible tilted positions of the probe with respect to the flat phantom surface. Visual inspection of the acquired volumes revealed that clinical requirements were fulfilled. Preliminary quantitative evaluation was also performed. The mean absolute distance (MAD) was calculated between actual anatomical structure positions and positions predicted by the CT-based algorithm. This resulted in a MAD of (2.8±0.4) mm for prostate, (2.5±0.6) mm for bladder and (2.8±0.6) mm for rectum. These results show that no significant systematic errors due to e.g. probe misplacement were introduced.

  17. Sex determination from scapular length measurements by CT scans images in a Caucasian population.

    Science.gov (United States)

    Giurazza, F; Schena, E; Del Vescovo, R; Cazzato, R L; Mortato, L; Saccomandi, P; Paternostro, F; Onofri, L; Zobel, B Beomonte

    2013-01-01

    Together with race, stature and age, sex is a main component of the biological identity. Thanks to its proportional correlation with parts of the human body, sex can be evaluated form the skeleton. The most accurate approach to determine sex by bone size is based on os coxae or skull. After natural disaster their presence can never be guaranteed, therefore the development of methods of sex determination using other skeletal elements can result crucial. Herein, sexual dimorphism in the human scapula is used to develop a two-variable discriminant function for sex estimation. We have enrolled 100 males and 100 females who underwent thoracic CT scan evaluation and we have estimated two scapular diameters. The estimation has been carried out by analyzing images of the scapulae of each patient after three dimensional post-processing reconstructions. The two-variable function allows to obtain an overall accuracy of 88% on the calibration sample. Furthermore, we have employed the mentioned function on a collection of 10 individual test sample from the collection of the "Museo di Anatomia Umana di Firenze" of the Università degli Studi di Firenze; sex has been correctly predicted on 9 skeletons.

  18. Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization

    Science.gov (United States)

    Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance

    2017-04-01

    Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.

  19. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Uros; Herk, Marcel van; Ploeger, Lennert S.; Sonke, Jan-Jakob, E-mail: j.sonke@nki.nl [Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam 1066 CX (Netherlands)

    2014-06-15

    Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different

  20. Rigid Registration of Freehand 3D Ultrasound and CT-Scan Kidney Images

    CERN Document Server

    Leroy, A; Payan, Y; Troccaz, J; Leroy, Antoine; Mozer, Pierre; Payan, Yohan; Troccaz, Jocelyne

    2004-01-01

    This paper presents a method to register a preoperative CT volume to a sparse set of intraoperative US slices. In the context of percutaneous renal puncture, the aim is to transfer a planning information to an intraoperative coordinate system. The spatial position of the US slices is measured by localizing a calibrated probe. Our method consists in optimizing a rigid 6 degree of freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The images have been preprocessed in order to increase the relationship between CT and US pixels. Correlation Ratio turned out to be the most accurate and appropriate similarity measure to be used in a Powell-Brent minimization scheme. Results are compared to a standard rigid point-to-point registration involving segmentation, and discussed.

  1. Anatomical basis for the interpretation of CT-scan imaging of the lumbar spine. Pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Laredo, J.D.; Bard, M.

    1988-01-01

    A good understanding of the normal anatomy of the lumbar spine is required for the interpretation of CT-scans obtained for ischiatic or crural neuralgia. An attempt has been made to rely on precise terminology to designate each anatomical region pertaining to the lumbar canal. Examples of tomodensitometric investigations of the normal intervertebral space are given, and criteria allowing for the identification of normal anatomical variations are also provided.

  2. Technical aspects of CT scanning.

    Science.gov (United States)

    Maravilla, K R; Pastel, M S

    1978-01-01

    The advent of computed tomography (CT) has initiated a technological revolution which continues to the present time. A brief review of basic principles of CT scanning is presented, and the evolution of modern CT scanner systems is traced. Some early indications of future trends are also presented.

  3. Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jonghwan; Pua, Rizza; Cho, Seungryong, E-mail: scho@kaist.ac.kr [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Kim, Insoo; Han, Bumsoo [EB Tech, Co., Ltd., 550 Yongsan-dong, Yuseong-gu, Daejeon 305-500 (Korea, Republic of)

    2015-11-15

    Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the

  4. A Hybrid Method for Segmentation and Visualization of Teeth in Multi-Slice CT scan Images

    Directory of Open Access Journals (Sweden)

    Mohammad Hosntalab

    2009-12-01

    Full Text Available Introduction: Various computer assisted medical procedures such as dental implant, orthodontic planning, face, jaw and cosmetic surgeries require automatic quantification and volumetric visualization of teeth. In this regard, segmentation is a major step. Material and Methods: In this paper, inspired by our previous experiences and considering the anatomical knowledge of teeth and jaws, we propose a hybrid technique for teeth segmentation and visualization in CT volumetric data. The major steps of the proposed techniques are as follows: (1 Separation of teeth in CT dataset; (2 Initial segmentation of teeth in panoramic projection; (3 Final segmentation of teeth in CT dataset; (4 3D visualization of teeth. Results: The proposed algorithm was evaluated in 30 multi-slice CT datasets. Segmented images were compared with manually outlined contours. In order to evaluate the proposed method, we utilized several common performance measures such as sensitivity, specificity, precision, accuracy and mean error rate. The experimental results reveal the effectiveness of the proposed method. Discussion and Conclusion: In the proposed algorithm, the variationallevel set technique was utilized to trace the contour of the teeth. In view of the fact that this technique is based on the characteristics of the overall region of the tooth image, it is possible to extract a very smooth and accurate tooth contour using this technique. For the available datasets, the proposed technique was more successful in teeth segmentation compared to previous techniques.

  5. Biomechanical Role of Bone Anisotropy Estimated on Clinical CT Scans by Image Registration.

    Science.gov (United States)

    Taghizadeh, Elham; Reyes, Mauricio; Zysset, Philippe; Latypova, Adeliya; Terrier, Alexandre; Büchler, Philippe

    2016-08-01

    Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

  6. Body CT (CAT Scan)

    Science.gov (United States)

    ... You may also be asked to remove hearing aids and removable dental work. Women will be asked to remove bras ... and surgical biopsy. No radiation remains in a patient's body after a CT ... side effects. Risks There is no conclusive evidence that radiation at ...

  7. Contribution of brain imaging techniques: CT-scan and magnetic resonance imaging (MRI); Apports de l`imagerie cerebrale (tomodensitometrie et imagerie par resonance magnetique)

    Energy Technology Data Exchange (ETDEWEB)

    Pasco-Papon, A.; Gourdier, A.L.; Papon, X.; Caron-Poitreau, C. [Centre Hospitalier Universitaire, 49 - Angers (France)

    1996-06-01

    In light of the current lack of consensus on the benefit of carotid artery surgery to treat asymptomatic carotid artery stenosis, the decision to operate on a patient depends on individual evaluation and characterization of risk factors on carotid artery stenosis greater than 70 %. The assessment of such risk factors is based especially on non-invasive brain imaging techniques.Computed tomography scanning (CT-scan) and magnetic resonance imaging (MRI) enable two types of stenosis to be differentiated, i.e. stenoses which are symptomatic and those that are radiologically proven versus those which are clinically and radiologically silent. CT-scan investigation (with and without injection of iodinated contrast media) still continues to be a common routine test in 1996 whenever a surgical revascularization procedure is planned. The presence of deep lacunar infarcts ipsilateral to the carotid artery stenosis generally evidence the reality of stenosis and thus are useful to the surgeon in establishing whether surgery is indicated. In the absence a consensus on indications for surgical management, the surgeon could use the CT-scan and MRI as medicolegal records which could be compared to a subsequent postoperative CT-scan in case of ischemic complications associated with the surgical procedure. Furthermore, recent cerebral ischemia as evidenced by filling with contrast material, will call for postponing treatment by a few weeks. Although conventional MRI is more contributive than brain CT-scan in terms of sensibility and specificity, its indications are narrower because of its limited availability and cost constraints. But, development of angio-MRI and functional imaging promise that its future is assured and even perhaps as the sole diagnostic method if its indications are expanded to include preoperative angiographic evaluation of atheromatous lesions of supra-aortic trunks. (authors). 37 refs.

  8. Detection of small hepatocellular carcinoma: Comparison of dynamic enhancement magnetic resonance imaging and multiphase multirow-detector helical CT scanning

    Institute of Scientific and Technical Information of China (English)

    Hong Zhao; Jin-Lin Yao; Ying Wang; Kang-Rong Zhou

    2007-01-01

    AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT)scanning for detection of small hepatocellular carcinoma (HCC).METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality.RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm)was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively.CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.

  9. Leg CT scan

    Science.gov (United States)

    ... x-ray beam rotates around you. (Modern "spiral" scanners can perform the exam without stopping.) A computer creates separate images of the body area, called slices. These images can be stored, viewed on a monitor, or printed on film. Three-dimensional (3D) models of the leg can be created by ...

  10. Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot.

    Science.gov (United States)

    Guéziec, A; Kazanzides, P; Williamson, B; Taylor, R H

    1998-10-01

    We describe new methods for rigid registration of a preoperative computed tomography (CT)-scan image to a set of intraoperative X-ray fluoroscopic images, for guiding a surgical robot to its trajectory planned from CT. Our goal is to perform the registration, i.e., compute a rotation and translation of one data set with respect to the other to within a prescribed accuracy, based upon bony anatomy only, without external fiducial markers. With respect to previous approaches, the following aspects are new: 1) we correct the geometric distortion in fluoroscopic images and calibrate them directly with respect to the robot by affixing to it a new calibration device designed as a radiolucent rod with embedded metallic markers, and by moving the device along two planes, while radiographs are being acquired at regular intervals; 2) the registration uses an algorithm for computing the best transformation between a set of lines in three space, the (intraoperative) X-ray paths, and a set of points on the surface of the bone (imaged preoperatively), in a statistically robust fashion, using the Cayley parameterization of a rotation; and 3) to find corresponding sets of points to the X-ray paths on the surfaces, our new approach consists of extracting the surface apparent contours for a given viewpoint, as a set of closed three-dimensional nonplanar curves, before registering the apparent contours to X-ray paths. Aside from algorithms, there are a number of major technical difficulties associated with engineering a clinically viable system using anatomy and image-based registration. To detect and solve them, we have so far conducted two experiments with the surgical robot in an operating room (OR), using CT and fluoroscopic image data of a cadaver bone, and attempting to faithfully simulate clinical conditions. Such experiments indicate that intraoperative X-ray-based registration is a promising alternative to marker-based registration for clinical use with our proposed method.

  11. Arm CT scan

    Science.gov (United States)

    ... scanners can perform the exam without stopping.) A computer creates separate images of the arm area, called ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  12. Abdominal CT scan

    Science.gov (United States)

    ... scanners can perform the exam without stopping. A computer creates separate images of the belly area. These ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  13. Shoulder CT scan

    Science.gov (United States)

    ... scanners can perform the exam without stopping.) A computer creates separate images of the shoulder area. These ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  14. Sinus CT scan

    Science.gov (United States)

    ... scanners can perform the exam without stopping.) A computer creates separate images of the body area. These ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  15. Investigation on the optical scan condition for imaging of multi-slice spiral CT liver perfusion in rats

    Institute of Scientific and Technical Information of China (English)

    BAI Rong-jie; WANG Jin-e; JIANG Hui-jie; HAO Xue-jia; DONG Xu-peng; HUANG Ya-hua; WEI Lai

    2013-01-01

    Background Multi-slice CT liver perfusion has been widely used in experimental studies of hemodynamic changes in liver lesions,and is usually performed as an adjunct to a conventional CT examination because of its high temporal and spatial resolution,simple protocol,good reproducibility,and ability to measure hemodynamic changes of liver tissues at the capillary level.Experimental rat models,especially those of induced liver cancer,are often used in studies of hemodynamic changes in liver cancer.Carcinogenesis in rats has a similar pathological progression and characteristics resembling those in human liver cancer; as a result,rat models are often used as ideal animal models in the study of human liver cancer.However,liver perfusion imaging in rats is difficult to perform,because rats' livers are so small that different concentrations,flow rates,and dose of contrast agents during the CT perfusion scanning can influence the quality of liver perfusion images in rats.The purpose of this study,therefore,was to investigate the optimal scan protocol for the imaging of hepatic perfusion using a deconvolution mathematical method in rats by comparing the results of rats in different injection conditions of the contrast agent,including concentration,rate and time.Methods Plain CT scan conditions in eighty 2-month-old male Wistar rats were 5.0 mm slice thickness,5.0 mm interval,1.0 pitch,120 kV tube voltage,60 mA tube current,512×512 matrix,and FOV 9.6 cm.Perfusion scanning was carried out with different concentrations of diatrizoate (19%,38%,57%,and 76%),different injection rates (0.3 and 0.5 mi/s),and different injection times (1,2-3,4-5,and 6 seconds).The above conditions were randomly matched and adjusted to determine the best perfusion scan protocol.Thrae-phase contrast-enhanced scanning was performed after CT perfusion.Histological examination of the liver tissues with hematoxylin and eosin stains was done after CT scanning.Results When the concentration of the

  16. Contextual Analysis of CT Scanned Pig Carcasses

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Larsen, Rasmus; Christensen, Lars Bager;

    2006-01-01

    Knowledge of the weight of tissue types in pig carcasses is generally only available after manual dissection. The use of computed tomography (CT) has demonstrated to be a promising approach to gain knowledge on the lean meat weight (Romvari, 2005), but less effort has been put into gaining...... knowledge about the weight of other tissue types from CT. Knowing the weight of individual tissue types will directly give access to other measures such as the weight of the carcass and the Lean Meat Percentage (LMP). Until now, most analyses of CT scans have been based on the Hounsfield spectra that does...... not consider the spatial context in CT scan. Applying contextual methods from the field of image analysis we hope to make a virtual dissection of pig carcasses....

  17. Investigation of the influence of image reconstruction filter and scan parameters on operation of automatic tube current modulation systems for different CT scanners.

    Science.gov (United States)

    Sookpeng, Supawitoo; Martin, Colin J; Gentle, David J

    2015-03-01

    Variation in the user selected CT scanning parameters under automatic tube current modulation (ATCM) between hospitals has a substantial influence on the radiation doses and image quality for patients. The aim of this study was to investigate the effect of changing image reconstruction filter and scan parameter settings on tube current, dose and image quality for various CT scanners operating under ATCM. The scan parameters varied were pitch factor, rotation time, collimator configuration, kVp, image thickness and image filter convolution (FC) used for reconstruction. The Toshiba scanner varies the tube current to achieve a set target noise. Changes in the FC setting and image thickness for the first reconstruction were the major factors affecting patient dose. A two-step change in FC from smoother to sharper filters doubles the dose, but is counterbalanced by an improvement in spatial resolution. In contrast, Philips and Siemens scanners maintained tube current values similar to those for a reference image and patient, and the tube current only varied slightly for changes in individual CT scan parameters. The selection of a sharp filter increased the image noise, while use of iDose iterative reconstruction reduced the noise. Since the principles used by CT manufacturers for ATCM vary, it is important that parameters which affect patient dose and image quality for each scanner are made clear to operator to aid in optimisation.

  18. Comparisons of Derived Metrics from Computed Tomography (CT) Scanned Images of Fluvial Sediment from Gravel-Bed Flume Experiments

    Science.gov (United States)

    Voepel, Hal; Ahmed, Sharif; Hodge, Rebecca; Leyland, Julian; Sear, David

    2016-04-01

    Uncertainty in bedload estimates for gravel bed rivers is largely driven by our inability to characterize arrangement, orientation and resultant forces of fluvial sediment in river beds. Water working of grains leads to structural differences between areas of the bed through particle sorting, packing, imbrication, mortaring and degree of bed armoring. In this study, non-destructive, micro-focus X-ray computed tomography (CT) imaging in 3D is used to visualize, quantify and assess the internal geometry of sections of a flume bed that have been extracted keeping their fabric intact. Flume experiments were conducted at 1:1 scaling of our prototype river. From the volume, center of mass, points of contact, and protrusion of individual grains derived from 3D scan data we estimate 3D static force properties at the grain-scale such as pivoting angles, buoyancy and gravity forces, and local grain exposure. Here metrics are derived for images from two flume experiments: one with a bed of coarse grains (>4mm) and the other where sand and clay were incorporated into the coarse flume bed. In addition to deriving force networks, comparison of metrics such as critical shear stress, pivot angles, grain distributions, principle axis orientation, and pore space over depth are made. This is the first time bed stability has been studied in 3D using CT scanned images of sediment from the bed surface to depths well into the subsurface. The derived metrics, inter-granular relationships and characterization of bed structures will lead to improved bedload estimates with reduced uncertainty, as well as improved understanding of relationships between sediment structure, grain size distribution and channel topography.

  19. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  20. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  1. Three-dimensional CT imaging with a helical scan on temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Sakakura, Atsushi; Yoshikawa, Shuji; Shimizu, Takaya; Sueyoshi, Kozo; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1996-06-01

    To evaluate the usefulness of three-dimensional (3D) CT on the lesions of temporal bone, we studied 19 patients with disorders on the region of temporal bone by high speed helical CT. The results showed that 8 patients with congenital hearing disorder had deficiency of the auditory ossicles, 2 patients with chronic otitis media had deformity and shortness of the auditory ossicles, 4 patients with trauma had fracture of the temporal bone (1 patient was complicated by doubtful fracture of the incus), 5 patients (4 patients with acquired hearing disorder and 1 patient with otorrhea) had space-occupying lesions. 3-D helical CT could detect abnormal findings on all the patients and it was an important examination for the temporal bone. (author)

  2. Image registration/fusion software for PET and CT/MRI by using simultaneous emission and transmission scans

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Keishi; Amano, Masaharu; Sato, Tomohiko [Shimadzu Corp., Medical Systems Division, Kyoto (Japan); Okumura, Takeshi [Shimadzu Corp., Technology Research Laboratory, Kyoto (Japan); Konishi, Norihiro; Komatsu, Masahiko [Shimadzu System Development Corp., Kyoto (Japan)

    2003-06-01

    When PET (positron emission tomography) is used for oncology studies, it is important to register and over-lay PET images with the images of other anatomical modalities, such as those obtained by CT (computed tomography) or MRI (magnetic resonance imaging), in order for the lesions to be anatomically located with high accuracy. The Shimadzu SET-2000W Series PET scanners provide simultaneous acquisition of emission and transmission data, which is capable of complete spatial alignment of both functional and attenuation images. This report describes our newly developed image registration/fusion software, which reformats PET emission images to the CT/MRI grid by using the transform matrix obtained by matching PET transmission images with CT/MRI images. Transmission images are registered and fused either automatically or manually, through 3-dimensional rotation and translation, with the transaxial, sagittal, and coronal fused images being monitored on the screen. This new method permits sufficiently accurate registration and efficient data processing with promoting effective use of CT/MRI images of the DICOM format, without using markers in data acquisition or any special equipment, such as a combined PET/CT scanner. (author)

  3. A case of catastrophic antiphospholipid syndrome, which presented an acute interstitial pneumonia-like image on chest CT scan.

    Science.gov (United States)

    Kameda, Tomohiro; Dobashi, Hiroaki; Susaki, Kentaro; Danjo, Junichi; Nakashima, Shusaku; Shimada, Hiromi; Izumikawa, Miharu; Takeuchi, Yohei; Mitsunaka, Hiroki; Bandoh, Shuji; Imataki, Osamu; Nose, Masato; Matsunaga, Takuya

    2015-01-01

    We report the case of catastrophic antiphospholipid syndrome (CAPS) complicated with mixed connective tissue disease (MCTD). A female patient was diagnosed with acute interstitial pneumonia (AIP) with MCTD by chest CT scan. Corticosteroid therapy was refractory for lung involvement, and she died due to acute respiratory failure. The autopsy revealed that AIP was compatible with lung involvement of CAPS. We therefore suggest that chest CT might reveal AIP-like findings in CAPS patients whose condition is complicated with pulmonary manifestations.

  4. Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan

    Science.gov (United States)

    Choi, Jang-Hwan; Muller, Kerstin; Hsieh, Scott; Maier, Andreas; Gold, Garry; Levenston, Marc; Fahrig, Rebecca

    2016-03-01

    C-arm-based cone-beam CT (CBCT) systems with flat-panel detectors are suitable for diagnostic knee imaging due to their potentially flexible selection of CT trajectories and wide volumetric beam coverage. In knee CT imaging, over-exposure artifacts can occur because of limitations in the dynamic range of the flat panel detectors present on most CBCT systems. We developed a straightforward but effective method for correction and detection of over-exposure for an Automatic Exposure Control (AEC)-enabled standard knee scan incorporating a prior low dose scan. The radiation dose associated with the low dose scan was negligible (0.0042mSv, 2.8% increase) which was enabled by partially sampling the projection images considering the geometry of the knees and lowering the dose further to be able to just see the skin-air interface. We combined the line integrals from the AEC and low dose scans after detecting over-exposed regions by comparing the line profiles of the two scans detector row-wise. The combined line integrals were reconstructed into a volumetric image using filtered back projection. We evaluated our method using in vivo human subject knee data. The proposed method effectively corrected and detected over-exposure, and thus recovered the visibility of exterior tissues (e.g., the shape and density of the patella, and the patellar tendon), incorporating a prior low dose scan with a negligible increase in radiation exposure.

  5. Metastatic Neuroblastoma in Adult Patient, Presenting as a Super Scan on 68Ga-DOTANOC PET/CT Imaging.

    Science.gov (United States)

    Malik, Dharmender; Jois, Abhiram; Singh, Harmandeep; Bora, Girdhar S; Basher, Rajender Kumar; Mittal, Bhagwant Rai

    2017-09-01

    We report a case of 23-year-old man who presented with complaints of progressive abdominal distension for the past 3 months along with the loss of appetite and weight and had a large solid cystic mass in the left half of the abdominal cavity revealed on ultrasonography and contrast-enhanced CT of the abdomen. Subsequent biopsy and histopathology revealed it to be neuroblastoma. Ga-DOTANOC PET/CT scan performed to rule out distant metastasis showed intense radiotracer uptake distributed throughout the skeleton, mimicking a super scan.

  6. Accurate IMRT fluence verification for prostate cancer patients using 'in-vivo' measured EPID images and in-room acquired kilovoltage cone-beam CT scans

    NARCIS (Netherlands)

    A.S.A.M. Ali (Ali Sid Ahmed M.); M.L.P. Dirkx (Maarten); R.M. Cools (Ruud); B.J.M. Heijmen (Ben)

    2013-01-01

    textabstractBackground: To investigate for prostate cancer patients the comparison of 'in-vivo' measured portal dose images (PDIs) with predictions based on a kilovoltage cone-beam CT scan (CBCT), acquired during the same treatment fraction, as an alternative for pre-treatment verification. For eval

  7. Nuclear magnetic resonance imaging with cardiac synchronization in chronic thrombosis of main pulmonary arteries. A case review with CT scan imaging correlation

    Energy Technology Data Exchange (ETDEWEB)

    Coulomb, M.; Wolf, J.E.; Rose-Pittet, L.; Le Bas, J.F.; Dalsoglio, S.; Paramelle, B.

    Results of nuclear magnetic resonance exploration in a patient with chronic thrombosis of main pulmonary arteries are used to outline an elementary semiology in agreement with current documented data. Signs observed relate to the thrombosis and showing of flow due to associated pulmonary artery hypertension. Cardiac synchronization is essential: obtaining 2 echos by the spin-echo technique allows differentiation of circulatory slowing phenomena, which provoke increased strength of 2nd echo, from the thrombus itself. Correlations established with V/Q scintigraphy, angiography and CT scan findings in this case provided preliminary evaluation of use of this imaging technique in this affection.

  8. Application of stereological estimates in patients with severe head injuries using CT and MR scanning images

    DEFF Research Database (Denmark)

    Eriksen, Nanna; Rostrup, E; Andersen, K;

    2010-01-01

    traditional imaging methods are not always applicable and automatic methods may not be able to match the individual observer. Stereological techniques are alternative tools in the quantitative description of biological structures, and have been increasingly applied to the human brain. In the present study, we...... estimation. The validity of phantom estimates was tested by the average deviation from the true geometric values, and was below 10%. The stereological methods were compared with more traditional region-based methods performed on medical imaging, which showed a CV below 7% and bias below 14%. It is concluded...

  9. Application of stereological estimates in patients with severe head injuries using CT and MR scanning images

    DEFF Research Database (Denmark)

    Eriksen, Nanna; Rostrup, E; Andersen, K;

    2010-01-01

    traditional imaging methods are not always applicable and automatic methods may not be able to match the individual observer. Stereological techniques are alternative tools in the quantitative description of biological structures, and have been increasingly applied to the human brain. In the present study, we......Severe brain damage is often followed by serious complications. Quantitative measurements, such as regional volume and surface area under various conditions, are essential for understanding functional changes in the brain and assessing prognosis. The affected brain tissue is variable, hence...... estimation. The validity of phantom estimates was tested by the average deviation from the true geometric values, and was below 10%. The stereological methods were compared with more traditional region-based methods performed on medical imaging, which showed a CV below 7% and bias below 14%. It is concluded...

  10. How parrots talk: insights based on CT scans, image processing, and mathematical models

    Science.gov (United States)

    Patterson, Dianne K.; Pepperberg, Irene M.; Story, Brad H.; Hoffman, Eric A.

    1997-05-01

    Little is known about mechanisms of speech production in parrots. Recently, however, techniques for correlating vocal tract shape with vowel production in humans have become more sophisticated and we have adapted these techniques for use with parrots. We scanned two grey parrot heads with intact vocal tracts. One specimen, 'Oldbird' was fixed with its beak propped open; the second 'Youngbird' was fixed with its beak closed. Using VIDA software, we (1) established that differences in tongue and larynx positioning resulted from opening or closing the beak; and (2) obtained lengths and area functions for the trachea, glottis, pharynx, mouth, and choana for both specimens and esophageal length and area functions for the first specimen. We entered lengths and area functions into a 1D wave propagation model to determine the natural formant frequencies associated with an open versus closed beak. We also determined how manipulating lengths and area functions could affect formant frequency and relative intensity. Finally, by comparing observed grey parrot vowel formant, we predict how the parrot uses its vocal tract to produce speech.

  11. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori [Kagoshima Univ. (Japan). Dental School

    1999-09-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  12. Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies

    Directory of Open Access Journals (Sweden)

    Xue Dong

    2013-01-01

    Full Text Available Excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT imaging. Compressed sensing (CS reconstruction algorithms show promises in recovering faithful signals from low-dose projection data but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter can be accurately measured and removed using measurement-based methods. However, these approaches are considered unpractical in the conventional FDK reconstruction, due to the inevitable primary loss for scatter measurement. We combine measurement-based scatter correction and CS-based iterative reconstruction to generate scatter-free images from low-dose projections. We distribute blocked areas on the detector where primary signals are considered redundant in a full scan. Scatter distribution is estimated by interpolating/extrapolating measured scatter samples inside blocked areas. CS-based iterative reconstruction is finally carried out on the undersampled data to obtain scatter-free and low-dose CBCT images. With only 25% of conventional full-scan dose, our method reduces the average CT number error from 250 HU to 24 HU and increases the contrast by a factor of 2.1 on Catphan 600 phantom. On an anthropomorphic head phantom, the average CT number error is reduced from 224 HU to 10 HU in the central uniform area.

  13. CT scan of the hypopharynx and larynx. Value of phonation scans

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Naoko; Anno, Hirofumi; Takahashi, Masaki; Koga, Sukehiko; Mori, Shigeki; Iwata, Shigenobu; Ikuta, Katsumi; Mashita, Shinichi.

    1988-08-01

    29 patients with hypopharyngeal or laryngeal disorders were sustained phonation of vowel /E/ at their comfortable pitch and intensity levels on their CT scans. These images were compared with CT scans during quiet breathing or breath holding. The pyriform sinuses and the aryepiglottic folds were better visualized and the details of the glottis and the laryngeal ventricles were demonstrable during phonation.

  14. Coronary calcium score scans for attenuation correction of quantitative PET/CT {sup 13}N-ammonia myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Burkhard, Nina; Herzog, Bernhard A.; Husmann, Lars; Pazhenkottil, Aju P.; Burger, Irene A.; Buechel, Ronny R.; Valenta, Ines; Wyss, Christophe A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2010-03-15

    The aim of this study was to evaluate whether ECG-triggered coronary calcium scoring (CCS) scans can be used for attenuation correction (AC) to quantify myocardial blood flow (MBF) and coronary flow reserve (CFR) assessed by PET/CT with {sup 13}N-ammonia. Thirty-five consecutive patients underwent a {sup 13}N-ammonia PET/CT scan at rest and during standard adenosine stress. MBF values were calculated using AC maps obtained from the ECG-triggered CCS scan during inspiration and validated against MBF values calculated using standard non-gated transmission scans for AC. CFR was calculated as the ratio of hyperaemic over resting MBF. In all 35 consecutive patients intraobserver variability was assessed by blinded repeat analysis for both AC methods. There was an excellent correlation between CT AC and CCS for global MBF values at rest (n = 35, r = 0.94, p < 0.001) and during stress (n = 35, r = 0.97, p < 0.001) with narrow Bland-Altman (BA) limits of agreement (-0.21 to 0.10 ml/min per g and -0.41 to 0.30 ml/min per g) as well as for global CFR (n = 35, r = 0.96, p < 0.001, BA -0.27 to 0.34). The excellent correlation was preserved on the segmental MBF analysis for both rest and stress (n = 1190, r = 0.93, p < 0.001, BA -0.60 to 0.50) and for CFR (n = 595, r = 0.87, p < 0.001, BA -0.71 to 0.74). In addition, reproducibility proved excellent for global CFR by CT AC (n = 35, r = 0.91, p < 0.001, BA -0.42-0.58) and CCS scans (n = 35, r = 0.94, p < 0.001, BA -0.34-0.45). Use of attenuation maps from CCS scans allows accurate quantitative MBF and CFR assessment with {sup 13}N-ammonia PET/CT. (orig.)

  15. Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model

    Science.gov (United States)

    Wang, Yang; Goldin, Jonathan G.; Abtin, Fereidoun G.; Brown, Matt; McNitt-Gray, Mike

    2008-03-01

    The purpose of this study is to test a new dynamic Perfusion-CT imaging protocol in an animal model and investigate the feasibility of quantifying perfusion of lung parenchyma to perform functional analysis from 4D CT image data. A novel perfusion-CT protocol was designed with 25 scanning time points: the first at baseline and 24 scans after a bolus injection of contrast material. Post-contrast CT scanning images were acquired with a high sampling rate before the first blood recirculation and then a relatively low sampling rate until 10 minutes after administrating contrast agent. Lower radiation techniques were used to keep the radiation dose to an acceptable level. 2 Yorkshire swine with pulmonary emboli underwent this perfusion- CT protocol at suspended end inspiration. The software tools were designed to measure the quantitative perfusion parameters (perfusion, permeability, relative blood volume, blood flow, wash-in & wash-out enhancement) of voxel or interesting area of lung. The perfusion values were calculated for further lung functional analysis and presented visually as contrast enhancement maps for the volume being examined. The results show increased CT temporal sampling rate provides the feasibility of quantifying lung function and evaluating the pulmonary emboli. Differences between areas with known perfusion defects and those without perfusion defects were observed. In conclusion, the techniques to calculate the lung perfusion on animal model have potential application in human lung functional analysis such as evaluation of functional effects of pulmonary embolism. With further study, these techniques might be applicable in human lung parenchyma characterization and possibly for lung nodule characterization.

  16. Improving the quality of reconstructed X-ray CT images of polymer gel dosimeters: zero-scan coupled with adaptive mean filtering.

    Science.gov (United States)

    Kakakhel, M B; Jirasek, A; Johnston, H; Kairn, T; Trapp, J V

    2017-02-06

    This study evaluated the feasibility of combining the 'zero-scan' (ZS) X-ray computed tomography (CT) based polymer gel dosimeter (PGD) readout with adaptive mean (AM) filtering for improving the signal to noise ratio (SNR), and to compare these results with available average scan (AS) X-ray CT readout techniques. NIPAM PGD were manufactured, irradiated with 6 MV photons, CT imaged and processed in Matlab. AM filter for two iterations, with 3 × 3 and 5 × 5 pixels (kernel size), was used in two scenarios (a) the CT images were subjected to AM filtering (pre-processing) and these were further employed to generate AS and ZS gel images, and (b) the AS and ZS images were first reconstructed from the CT images and then AM filtering was carried out (post-processing). SNR was computed in an ROI of 30 × 30 for different pre and post processing cases. Results showed that the ZS technique combined with AM filtering resulted in improved SNR. Using the previously-recommended 25 images for reconstruction the ZS pre-processed protocol can give an increase of 44% and 80% in SNR for 3 × 3 and 5 × 5 kernel sizes respectively. However, post processing using both techniques and filter sizes introduced blur and a reduction in the spatial resolution. Based on this work, it is possible to recommend that the ZS method may be combined with pre-processed AM filtering using appropriate kernel size, to produce a large increase in the SNR of the reconstructed PGD images.

  17. New Technique for Automatic Segmentation of Blood Vessels in CT Scan Images of Liver Based on Optimized Fuzzy C-Means Method

    Directory of Open Access Journals (Sweden)

    Katayoon Ahmadi

    2016-01-01

    Full Text Available Automatic segmentation of medical CT scan images is one of the most challenging fields in digital image processing. The goal of this paper is to discuss the automatic segmentation of CT scan images to detect and separate vessels in the liver. The segmentation of liver vessels is very important in the liver surgery planning and identifying the structure of vessels and their relationship to tumors. Fuzzy C-means (FCM method has already been proposed for segmentation of liver vessels. Due to classical optimization process, this method suffers lack of sensitivity to the initial values of ​​class centers and segmentation of local minima. In this article, a method based on FCM in conjunction with genetic algorithms (GA is applied for segmentation of liver’s blood vessels. This method was simulated and validated using 20 CT scan images of the liver. The results showed that the accuracy, sensitivity, specificity, and CPU time of new method in comparison with FCM algorithm reaching up to 91%, 83.62, 94.11%, and 27.17 were achieved, respectively. Moreover, selection of optimal and robust parameters in the initial step led to rapid convergence of the proposed method. The outcome of this research assists medical teams in estimating disease progress and selecting proper treatments.

  18. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Directory of Open Access Journals (Sweden)

    Paoli Alessandro

    2011-02-01

    Full Text Available Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast and preoperative (radiographic template models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology.

  19. Attenuation and image quality in the use of protective bismuth in chest CT scans; Atenuacion y calidad de imagen en el empleo de protectores de bismuto en exploraciones de TC de torax

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Ruiz-Zorrila, J.; Fernandez Leton, P.; Martinez Gomez, L. C.; Casa de Julian, M. A. de la; Gilarranz Moreno, R.; Zucca Aparicio, D.; Minambres Moro, A.; Perez Moreno, J. M.

    2011-07-01

    For chest CT scans are protective of bismuth (Bi) with the aim of reducing the dose in the breast. The aim of this study was to evaluate the attenuation with thermoluminescent dosimeters in the glandular dose average when using these protective breast CT scans and to evaluate the image quality with and without protective Bismuth.

  20. Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

    Energy Technology Data Exchange (ETDEWEB)

    Sriwayu, Wa Ode [Physics Departement, Haluoleo University Indonesia (Indonesia); Haryanto, Freddy; Khotimah, Siti Nurul; Latief, Fourier Dzar Eljabbar [Physics Departement, ITB Indonesia email : ayoe-fisika@yahoo.com (Indonesia)

    2015-04-16

    We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

  1. Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Antoine; Mozer, Pierre; Payan, Yohan; Troccaz, Jocelyne [TIMC Lab - IN3S, Faculte de Medecine, La Tronche cedex (France)

    2007-06-15

    Objectives This paper presents a method to register a pre-operative computed-tomography (CT) volume to a sparse set of intra-operative ultra-sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. Materials and methods The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 degree of freedom transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images were preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, correlation ratio turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent's. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. Results The obtained results are presented and discussed. (orig.)

  2. Intensity-Based Registration of Freehand 3D Ultrasound and CT-scan Images of the Kidney

    CERN Document Server

    Leroy, Antoine; Payan, Yohan; Troccaz, Jocelyne

    2007-01-01

    This paper presents a method to register a pre-operative Computed-Tomography (CT) volume to a sparse set of intra-operative Ultra-Sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 Degree Of Freedom (DOF) transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images have been preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, Correlation Ratio (CR) turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, n...

  3. Three-Dimensional Image Fusion of SPECT and CT Scans for Locating Sentinel Lymph Nodes in Malignant Melanomas

    Directory of Open Access Journals (Sweden)

    Michiko Akiyama

    2011-03-01

    Full Text Available Image fusion software can derive a fusion image from single photon emission computed tomography and computed tomography scans. We applied a three-dimensional fusion image to detect sentinel lymph nodes (SLNs in 3 patients with malignant melanomas of the lumbar, vulvar and head region, respectively. During each operation, we detected SLNs at the expected site, as indicated by the fusion images. The three-dimensional image fusion could thus be confirmed as a simple and helpful method for precisely localizing SLNs in these patients.

  4. Image-based compensation for involuntary motion in weight-bearing C-arm cone-beam CT scanning of knees

    Science.gov (United States)

    Unberath, Mathias; Choi, Jang-Hwan; Berger, Martin; Maier, Andreas; Fahrig, Rebecca

    2015-03-01

    We previously introduced four fiducial marker-based strategies to compensate for involuntary knee-joint motion during weight-bearing C-arm CT scanning of the lower body. 2D methods showed significant reduction of motion- related artifacts, but 3D methods worked best. However, previous methods led to increased examination times and patient discomfort caused by the marker attachment process. Moreover, sub-optimal marker placement may lead to decreased marker detectability and therefore unstable motion estimates. In order to reduce overall patient discomfort, we developed a new image-based 2D projection shifting method. A C-arm cone-beam CT system was used to acquire projection images of five healthy volunteers at various flexion angles. Projection matrices for the horizontal scanning trajectory were calibrated using the Siemens standard PDS-2 phantom. The initial reconstruction was forward projected using maximum-intensity projections (MIP), yielding an estimate of a static scan. This estimate was then used to obtain the 2D projection shifts via registration. For the scan with the most motion, the proposed method reproduced the marker-based results with a mean error of 2.90 mm +/- 1.43 mm (compared to a mean error of 4.10 mm +/- 3.03 mm in the uncorrected case). Bone contour surrounding modeling clay layer was improved. The proposed method is a first step towards automatic image-based, marker-free motion-compensation.

  5. Ultra-low-dose dual-source CT coronary angiography with high pitch: diagnostic yield of a volumetric planning scan and effects on dose reduction and imaging strategy

    Science.gov (United States)

    Hamm, B; Huppertz, A; Lembcke, A

    2015-01-01

    Objective: To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. Methods: 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. Results: Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. Conclusion: An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. Advances in knowledge: Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure. PMID:25710210

  6. Morphometric measurement of the patella on 3D model reconstructed from CT scan images for the southern Chinese population

    Institute of Scientific and Technical Information of China (English)

    Shang Peng; Zhang Linan; Hou Zengtao; Bai Xueling; Ye Xin; Xu Zhaobin; Huang Xu

    2014-01-01

    Background Due to racial differences in the morphology of the knee joint and due to most prostheses available in the market being designed using measurements from Caucasians,the objective of this study was to provide the morphometric data of the patella for the southern Chinese population for total knee arthroplasty (TKA),patellar resurfacing,and prostheses design.Methods The CT slices of the knee joint were obtained from both knees of 40 Chinese volunteers (20 females,20 males,and age from 20-25 years) by performing a computer tomographic scan.A 3D model was reconstructed by Mimics software based on the computed tomography images.Six metrical characteristics were measured by digital ruler.Statistical analysis was performed with the SPSS statistical program.Results The mean,standard deviation and P values of measurements and ratios were calculated using SPSS.All dimensions showed a significant gender difference with P<0.05,but the six variables of the left and right knees had no statistical significance with P>0.05.In addition,we studied the relationship between six couples (H-W,H-T,H-HAF,W-T,W-HAF,T-HAF) of the four variables (H:height,W:width,T:thickness and HAF:height of articulating facet) that were measured,which showed a significant correlation.Conclusions Examination of the southern Chinese population revealed that males have larger patellae than women.In both genders,comparing data between left and right knees shows no statistically significant difference.Compared with Westerners in previous studies,the patella in our study was thin and small.There was a good linear regression correlation between measurements of the patella.The indirect measurement method on 3D models makes it easy to obtain anatomical data,and the results can provide a region and gender specific database for morphometric measurements of the oatella,and can be helpful for designing implants suited for southern Chinese patients.

  7. Computer-aided diagnosis: a 3D segmentation method for lung nodules in CT images by use of a spiral-scanning technique

    Science.gov (United States)

    Wang, Jiahui; Engelmann, Roger; Li, Qiang

    2008-03-01

    Lung nodule segmentation in computed tomography (CT) plays an important role in computer-aided detection, diagnosis, and quantification systems for lung cancer. In this study, we developed a simple but accurate nodule segmentation method in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. We then transformed the VOI into a two-dimensional (2D) image by use of a "spiral-scanning" technique, in which a radial line originating from the center of the VOI spirally scanned the VOI. The voxels scanned by the radial line were arranged sequentially to form a transformed 2D image. Because the surface of a nodule in 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified our segmentation method and enabled us to obtain accurate segmentation results. We employed a dynamic programming technique to delineate the "optimal" outline of a nodule in the 2D image, which was transformed back into the 3D image space to provide the interior of the nodule. The proposed segmentation method was trained on the first and was tested on the second Lung Image Database Consortium (LIDC) datasets. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric. The experimental results on the LIDC database demonstrated that our segmentation method provided relatively robust and accurate segmentation results with mean overlap values of 66% and 64% for the nodules in the first and second LIDC datasets, respectively, and would be useful for the quantification, detection, and diagnosis of lung cancer.

  8. Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study.

    Science.gov (United States)

    Chen, Han; Danielsson, Mats; Xu, Cheng

    2016-06-07

    We are developing a photon-counting spectral CT detector with a small pixel size of [Formula: see text] mm(2), offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, [Formula: see text], with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, [Formula: see text]dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference

  9. Size-dependent scanning parameters (kVp and mAs) for photon-counting spectral CT system in pediatric imaging: simulation study

    Science.gov (United States)

    Chen, Han; Danielsson, Mats; Xu, Cheng

    2016-06-01

    We are developing a photon-counting spectral CT detector with a small pixel size of 0.4× 0.5 mm2, offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. Cylindrical soft-tissue phantoms of diameters between 10-25 cm were used to mimic patients of different ages from 0 to 15 y. For adipose imaging, a 5 mm diameter adipose sphere was assumed as an imaging target, while in the case of iodinated imaging, an iodinated blood sphere of 1 mm in diameter was assumed. By applying the geometry of a commercial CT scanner (GE Lightspeed VCT), simulations were carried out to calculate the detectability index, {{d}\\prime 2} , with tube potentials varying from 40 to 140 kVp. The optimal kVp for each phantom in each imaging case was determined such that the dose-normalized detectability index, {{d}\\prime 2}/ dose, is maximized. With the assumption that the detectability index in pediatric imaging is required the same as in typical adult imaging, the value of mAs at optimal kVp for each phantom was selected to achieve a reference detectability index that was obtained by scanning an adult phantom (30 cm in diameter) in a typical adult CT procedure (120 kVp and 200 mAs) using a modeled energy-integrating system. For adipose imaging, the optimal kVps are 50, 60, 80, and 120 kVp, respectively, for phantoms of 10, 15, 20, and 25 cm in diameter. The corresponding mAs values required to achieve the reference detectability index are only 9%, 23%, 24%, and 54% of the mAs that is used for adult patients at 120 kVp, for 10, 15, 20, and 25 cm diameter phantoms, respectively. In the case of iodinated imaging, a tube potential of 60 kVp was found optimal for all phantoms investigated, and the mAs values required to achieve the reference detectability

  10. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin;

    2012-01-01

    on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...... inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant......This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...

  11. Diagnostic accuracy of CT scan in abdominal blunt trauma

    Institute of Scientific and Technical Information of China (English)

    Javad Salimi; Khadyjeh Bakhtavar; Mehdi Solimani; Patrcia Khashayar; Ali Pasha Meysamie; Moosa Zargar

    2009-01-01

    Obiective: To evaluate the sensitivity and specificity of CT scan findings in Patients ith blunt abdominal trauma admitted to the university hospital.Methods: All the atients ith blunt abdominal trauma admitted at a tertiary teaching trauma center in Iran between 2005 and 2007 were enrolled in this study.In the absence of any clinical anifestations,he patients underwent a diagnostic CT scan.Laparatomy was performed in those with positive CT results.Others were observed for 48 hours and discharged in case no problem as reported;otherwise they underwent laparatomy.Information on patients'demographic ata,mechanism of trauma,indication for CT scan,CT scan findings,results of laparotomy ere gathered.The sensitivity,specificity and accuracy of the CT-scan images in regard ith the organ injured were calculated.The sensitivity,specificity and accuracy of the T scan were calculated in each case.Results: CT Scan had the highest sensitivity for etecting the injuries to liver (100%) and spleen (86.6%).The specificity of the method or detecting retroperitoneal hematoma (100%) and injuries to kidney (93.5%) was higher han other organs.The accuracy of CT images to detect the injuries to spleen,liver,idney and retroperitoneal hematoma was reported to be 96.1%,94.4%,91.6% and 91.6% espectively.Conclusion: The findings of the present study reveal that CT scan could econsidered as a good choice,especially for patients with blunt abdominal trauma in eaching hospitals where the radiologic academic staff is not present in the hospital in the night shifts.

  12. Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior

    Science.gov (United States)

    Ma, Jianhua; Zhang, Hua; Gao, Yang; Huang, Jing; Liang, Zhengrong; Feng, Qianjing; Chen, Wufan

    2012-11-01

    Cerebral perfusion x-ray computed tomography (PCT) imaging, which detects and characterizes the ischemic penumbra, and assesses blood-brain barrier permeability with acute stroke or chronic cerebrovascular diseases, has been developed extensively over the past decades. However, due to its sequential scan protocol, the associated radiation dose has raised significant concerns to patients. Therefore, in this study we developed an iterative image reconstruction algorithm based on the maximum a posterior (MAP) principle to yield a clinically acceptable cerebral PCT image with lower milliampere-seconds (mA s). To preserve the edges of the reconstructed image, an edge-preserving prior was designed using a normal-dose pre-contrast unenhanced scan. For simplicity, the present algorithm was termed as ‘MAP-ndiNLM’. Evaluations with the digital phantom and the simulated low-dose clinical brain PCT datasets clearly demonstrate that the MAP-ndiNLM method can achieve more significant gains than the existing FBP and MAP-Huber algorithms with better image noise reduction, low-contrast object detection and resolution preservation. More importantly, the MAP-ndiNLM method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the MAP-Huber method.

  13. Preoperative CT scanning of 70 cases of rheumatic valvular disease

    Energy Technology Data Exchange (ETDEWEB)

    Take, Akira; Matuzaki, Shigeru; Oki, Shinichi (Jichi Medical School, Minamikawachi, Tochigi (Japan)) (and others)

    1992-05-01

    Seventy patients with rheumatic valvular disease were evaluated with preoperative CT scanning. The correlation of the obtained CT images to the operative findings were examined. Left atrial thrombi were found in 24 cases at the operation. CT scan had detected thrombi in 19 cases (79.2%) and echocardiography in 15 (62.5%). CT failed to find them in 5 cases in which the left atrial thrombi were less than 3 g. Echocardiogram, however, failed to detect thrombi in 9 cases, the largest being 14 g. There were 15 cases with left atrial calcification, in which 10 cases had left atrial thrombi. Nine cases out of these 10 cases had rough left atrial surface after thrombectomy. Early postoperative CT of 10 with left atrial calcification showed recurrent left atrial thrombi in 4 (40%) cases. Mitral valve calcification was found in 42 cases during operation. CT scan was able to detect it in 40 (95.2%), while echocardiogram detected in 34 cases (81.0%) (p<0.05). All mitral valves with calcification required replacement. Out of 30 cases with non calcified mitral valves, 9 underwent OMC, and the other 21 underwent mitral valve replacement. Aortic valve calcification was found in 9 out of 11 cases of aortic stenosis. All has been diagnosed by CT scan. In conclusion, 1. in detecting the left atrial thrombi, CT scan was superior to echo-cardiography, and provided useful information for planning the operative procedure including atrial approach and valvular manipulation, 2. CT scan could detect calcification of left atrial wall which had high incidence of thrombus formation and rough left atrial surface, 3. CT scan could detect calcification of both mitral and aortic valve, and showed the severity of valvular structural changes. (author).

  14. Evaluation strategies in CT scanning

    DEFF Research Database (Denmark)

    uncertainty. This investigation includes measurements of two industrial items, an aluminum pipe connector and a plastic toggle, a hearing aid component. These are measured using a commercial CT scanner. Traceability is transferred using tactile and optical coordinate measuring machines, which are used...

  15. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  16. Indications for CT scanning in minor head injuries: a review.

    Science.gov (United States)

    Żyluk, Andrzej

    2015-01-01

    To determine indications for performing head CT following minor head injuries, which allow reducing number of imaging. Based on 15 articles dedicated to this topic, the clinical decision rules were systematically analysed. The Canadian Computed Tomography Head Rule was found to be the most reliable instrument meeting these criteria, characterised by excellent sensitivity of 100% and fairly good specificity of 48-77%. Remaining scales, although very sensitive, showed poor ability to reduce number of "unnecessary" CT scans. Features most predictive for intracranial injuries included: disorientation, abnormal alertness, somnolentia and neurological deficits. Patients with no loss of consciousness and in normal physical condition need only clinical assessment. Indications to head CT scanning are determined by decision rules presented in the article. Use of clinical decision rules may have effect on reducing number of head CT scanning performed "just in a case". Copyright © 2015 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  17. CT scan of bacterial and aseptic meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi (Kobe Central Municipal Hospital (Japan))

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of the 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role.

  18. Photothermal imaging scanning microscopy

    Science.gov (United States)

    Chinn, Diane; Stolz, Christopher J.; Wu, Zhouling; Huber, Robert; Weinzapfel, Carolyn

    2006-07-11

    Photothermal Imaging Scanning Microscopy produces a rapid, thermal-based, non-destructive characterization apparatus. Also, a photothermal characterization method of surface and subsurface features includes micron and nanoscale spatial resolution of meter-sized optical materials.

  19. An Edge Detection Method for Brain CT Scan Images Based on LVQ Neural Network%基于 LVQ 神经网络脑部 CT 边缘检测方法的研究

    Institute of Scientific and Technical Information of China (English)

    张喜红

    2016-01-01

    研究运用LVQ神经网络进行脑部CT图像边缘检测的方法,以提高边缘检测的准确度。使用传统的Sobel算法对脑部CT图像进行边缘检测,作为网络学习的教师信号,并将脑部CT图像的中值特征量、方向性信息特征量、Krisch算子方向特征量3项特征量作为LVQ神经网络的输入信号,进行网络训练后,再将训练好的网络进行边缘检测。在Matlab 2010平台下进行仿真对比,结果显示改进算法边缘检测结果与实际相符,比传统Sobel算法更具优越性。%An edge detection method for brain CT scan images using LVQ neural network is studied to enhance the accuracy of edge detection.First, the traditional Sobel algorithm is used to detect the edge of brain CT scan images as the teacher′s signal for network learning.Second,the value of the median,the direc-tion of information characteristics,the direction of the characteristics of the Krisch operator of brain CT scan images are adopted as the input signal of the LVQ neural network to conduct network training.Finally,the trained neural network is used for edge detection.Comparison of computer simulations on Matlab 2010 shows that the improved method can achieve a credible result and has a better detection effect than the traditional Sobel algorithm.

  20. Automated lung segmentation of low resolution CT scans of rats

    Science.gov (United States)

    Rizzo, Benjamin M.; Haworth, Steven T.; Clough, Anne V.

    2014-03-01

    Dual modality micro-CT and SPECT imaging can play an important role in preclinical studies designed to investigate mechanisms, progression, and therapies for acute lung injury in rats. SPECT imaging involves examining the uptake of radiopharmaceuticals within the lung, with the hypothesis that uptake is sensitive to the health or disease status of the lung tissue. Methods of quantifying lung uptake and comparison of right and left lung uptake generally begin with identifying and segmenting the lung region within the 3D reconstructed SPECT volume. However, identification of the lung boundaries and the fissure between the left and right lung is not always possible from the SPECT images directly since the radiopharmaceutical may be taken up by other surrounding tissues. Thus, our SPECT protocol begins with a fast CT scan, the lung boundaries are identified from the CT volume, and the CT region is coregistered with the SPECT volume to obtain the SPECT lung region. Segmenting rat lungs within the CT volume is particularly challenging due to the relatively low resolution of the images and the rat's unique anatomy. Thus, we have developed an automated segmentation algorithm for low resolution micro-CT scans that utilizes depth maps to detect fissures on the surface of the lung volume. The fissure's surface location is in turn used to interpolate the fissure throughout the lung volume. Results indicate that the segmentation method results in left and right lung regions consistent with rat lung anatomy.

  1. Quantitative Techniques in PET-CT Imaging

    NARCIS (Netherlands)

    Basu, Sandip; Zaidi, Habib; Holm, Soren; Alavi, Abass

    2011-01-01

    The appearance of hybrid PET/CT scanners has made quantitative whole body scanning of radioactive tracers feasible. This paper deals with the novel concepts for assessing global organ function and disease activity based on combined functional (PET) and structural (CT or MR) imaging techniques, their

  2. MRI of patients with cerebral palsy and normal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Bogaert, P. van; Szliwowski, H.B. (Hopital Erasme, Brussels (Belgium). Dept. of Neurology); Baleriaux, D.; Christophe, C. (Hopital Erasme, Brussels (Belgium). Dept. of Radiology (Neuroradiology))

    1992-02-01

    Three children with clinical evidence of cerebral palsy (CP) and normal cerebral computed tomography (CT) scans were evaluated by magnetic resonance imaging (MRI) to identify CT-undetectable white matter lesions in the watershed zones of arterial territories. The two patients with spastic diplegia showed bilateral lesions either in the subcortical regions or in the occipital periventricular regions. The patient with congenital hemiplegia exhibited unilateral lesions in the periventricular region. We conclude that MRI is more informative than CT for the evaluation of patients with CP. (orig.).

  3. Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners

    Energy Technology Data Exchange (ETDEWEB)

    Kotasidis, F A; Matthews, J C; Angelis, G I; Noonan, P J; Jackson, A [Imaging, Genomics and Proteomics, Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester (United Kingdom); Price, P [Academic Department of Radiation Oncology, University of Manchester, Manchester (United Kingdom); Lionheart, W R [School of Mathematics, Alan Turing Building, University of Manchester, Manchester (United Kingdom); Reader, A J, E-mail: fotis.kotasidis@mmic.man.ac.uk [Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, QC (Canada)

    2011-05-21

    Incorporation of a resolution model during statistical image reconstruction often produces images of improved resolution and signal-to-noise ratio. A novel and practical methodology to rapidly and accurately determine the overall emission and detection blurring component of the system matrix using a printed point source array within a custom-made Perspex phantom is presented. The array was scanned at different positions and orientations within the field of view (FOV) to examine the feasibility of extrapolating the measured point source blurring to other locations in the FOV and the robustness of measurements from a single point source array scan. We measured the spatially-variant image-based blurring on two PET/CT scanners, the B-Hi-Rez and the TruePoint TrueV. These measured spatially-variant kernels and the spatially-invariant kernel at the FOV centre were then incorporated within an ordinary Poisson ordered subset expectation maximization (OP-OSEM) algorithm and compared to the manufacturer's implementation using projection space resolution modelling (RM). Comparisons were based on a point source array, the NEMA IEC image quality phantom, the Cologne resolution phantom and two clinical studies (carbon-11 labelled anti-sense oligonucleotide [{sup 11}C]-ASO and fluorine-18 labelled fluoro-l-thymidine [{sup 18}F]-FLT). Robust and accurate measurements of spatially-variant image blurring were successfully obtained from a single scan. Spatially-variant resolution modelling resulted in notable resolution improvements away from the centre of the FOV. Comparison between spatially-variant image-space methods and the projection-space approach (the first such report, using a range of studies) demonstrated very similar performance with our image-based implementation producing slightly better contrast recovery (CR) for the same level of image roughness (IR). These results demonstrate that image-based resolution modelling within reconstruction is a valid alternative to

  4. Optical flow and image segmentation analysis for noninvasive precise mapping of microwave thermal ablation in X-ray CT scans - ex vivo study.

    Science.gov (United States)

    Ziv, Omri; Goldberg, S Nahum; Nissenbaum, Yitzhak; Sosna, Jacob; Weiss, Noam; Azhari, Haim

    2017-09-20

    To develop image processing algorithms for noninvasive mapping of microwave thermal ablation using X-ray CT. Ten specimens of bovine liver were subjected to microwave ablation (20-80 W, 8 min) while scanned by X-ray CT at 5 s intervals. Specimens were cut and manually traced by two observers. Two algorithms were developed and implemented to map the ablation zone. The first algorithm utilises images segmentation of Hounsfield units changes (ISHU). The second algorithm utilises radial optical flow (ROF). Algorithm sensitivity to spatiotemporal under-sampling was assessed by decreasing the acquisition rate and reducing the number of acquired projections used for image reconstruction in order to evaluate the feasibility of implementing radiation reduction techniques. The average radial discrepancy between the ISHU and ROF contours and the manual tracing were 1.04±0.74 and 1.16±0.79mm, respectively. When diluting the input data, the ISHU algorithm retained its accuracy, ranging from 1.04 to 1.79mm. By contrast, the ROF algorithm performance became inconsistent at low acquisition rates. Both algorithms were not sensitive to projections reduction, (ISHU: 1.24±0.83mm, ROF: 1.53±1.15mm, for reduction by eight fold). Ablations near large blood vessels affected the ROF algorithm performance (1.83±1.30mm; p mapping algorithms can provide highly accurate contouring of the ablation zone at low scan rates. The ISHU algorithm may be more suitable for clinical practice as it appears more robust when radiation dose reduction strategies are employed and when the ablation zone is near large blood vessels.

  5. CT image of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Morioka, Nobuo; Shudo, Yuji; Jahana, Masanobu; Matsuki, Tsutomu; Kotani, Kazuhiko (Tottori Univ., Yonago (Japan). School of Medicine)

    1983-10-01

    Computor tomographic images of 11 patients who had had thymectomy for myasthenia gravis or thymoma were studied retrospectively. Of those 11 patients, malignant thymoma and benign condition including normal thymus were 6 and 5 respectively. On CT, calcification and lobulation with irregular margin seem to be reliable findings of malignancy. Defect or abscence of fatty plane and non-homogenous density are ancillary.

  6. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    OpenAIRE

    Paoli Alessandro; Barone Sandro; Chessa Giacomo; Frisardi Gianni; Razionale Armando; Frisardi Flavio

    2011-01-01

    Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgi...

  7. Artifacts and pitfalls of high-resolution CT scans.

    Science.gov (United States)

    Hahn, F J; Chu, W K; Anderson, J C; Dobry, C A

    1985-01-01

    Artifacts on CT images have been observed since the introduction of CT scanners. Some artifacts have been corrected with the improvement of technology and better understanding of the image formation and reconstruction algorithms. Some artifacts, however, are still observable in state-of-the-art high-resolution scans. Many investigations on CT artifacts have been reported. Some artifacts are obvious and some are similar to patterns commonly associated with pathological conditions. The present report summarizes some of the causes of artifacts and presents some artifacts that mimic pathology on clinical scans of the head and spine. It is the intention of this report to bring these artifacts and potential pitfalls to the attention of the radiologists so that misinterpretation can be avoided.

  8. Study on Flash scan combined with iterative reconstruction in chest CT scan: image quality and radiation dose%Flash扫描联合迭代重建技术在胸部CT中的可行性研究

    Institute of Scientific and Technical Information of China (English)

    陈小芳; 沈莉

    2015-01-01

    Objective To assess radiation dose and image quality of chest CT examinations that acquired with Flash scan technique combined with iterative reconstruction.Methods Thirty continuous patients required no-contrast chest CT with Flash scan mode and contrast enhanced chest CT with conventional CT scan mode.For each examination,the images were reconstructed by filter back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE).The volume CT dose index (CTDIvol),dose-length product (DLP),and effective dose (ED) were estimated.The image noise,signal to noise ratio (SNR),overall subjective image quality,and respiratory motion artifacts were evaluated blindly by two radiologists.Results For Flash scan and conventional scan,SAFIRE reduced the image noise 35% and 16%,respectively;and increased SNR 21.9% and 25% compared to FBP,respectively (P <0.05).There was significant lower subjective image scores acquired by SAFIRE than by FBP.Flash scan reduced the CTDIvol (mGy) 40.9%,DLP 32.1%,and ED 26.9% compared to conventional CT scan mode.The motion artifact scores were reduced significantly with Flash scan mode compared to conventional scan mode.Conclusions Flash scan technique of the chest can obtain image with minimum respiratory motion artifact due to dramatically increased scan speed,and when SAFIRE was combined with,it reduces significantly radiation dose and image noise.%目的 研究Flash扫描技术与迭代重建联合应用在胸部CT中对图像质量及辐射剂量的影响.方法 2014年12月至2015年4月本科进行胸部Flash扫描及常规螺旋扫描CT的连续30例患者,其中Flash扫描序列采用FLash螺旋扫描,常规螺旋扫描序列采用常规螺旋扫描,图像分别进行滤波反投影重建(FBP)及迭代重建(SAFIRE),两位放射科医师在未告知图像参数的情况下,对CT容积辐射指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)、图像噪声、信噪比及总体主观图像质量、

  9. CT evaluation of solitary pulmonary nodule : value of additional HRCT scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Kwak Jin Young; Lee, Seung Ik; Ha, Doo Hoe [Pundang CHA General Hospital, Pochon CHA Univ. College of Medicine, Sungnam (Korea, Republic of); Kim, Tae Sung; Hwang, Jung Hwa; Lee, Kyung Soo [Samsung Medical Center, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Yook Yung [Ewha Womans Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-04-01

    The aim of our study was to evaluate the usefulness of high-resolution CT scans in addition to helical CT for characterizing a solitary pulmonary nodule. Our study included 49 patients with a solitary pulmonary nodule ; in each patient this was evaluated by both additional high-resolution CT and helical scanning. Images were evaluated by three independent observers, each of whom read them twice : initially with helical CT images only and then with helical images plus high-resolution CT images. After analysis, the observers recorded the following : histologic diagnosis, benignancy or malignancy of a nodule, and confidence in their diagnosis (three scales). In differentiating benign and malignant nodules, the accuracy of helical scans only was 75% (110/147 readings) whereas that of helical plus high-resolution CT scans was 82% (121/147 readings)({rho}=0.001). Correct histologic diagnosis was made in 47% of cases (69/147 readings) when helical scans only had been evaluated and in 48% of cases (71/147 readings) for which both helical and high-resolotion CT scans were available ({rho}=0.815). Diagnosis was more often highly confident on the basis of additional high-resolution CT scans (25%) than helical scans only (5%) ({rho}=0.001). By enhancing differential diagnostic accuracy between benign and malignant nodules and by increasing confidence in the histologic diagnosis of a pulmonary nodule, additional high-resolution CT scans are valuable for the evaluation of a solitary pulmonary nodule.

  10. Virtual CT laparoscopic imaging using intravenous cholangiography with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Masafumi; Ishibashi, Masatoshi; Nishimura, Hiroshi; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine

    2000-08-01

    Laparoscopic cholecystectomy is a reatively new technology that allows for minimally invasive treatment of cholelithiasis. The purpose of this paper is to demonstrate the feasibility of virtual laparoscopic imaging using helical CT cholangiography with volume rendering technique. We used the technique with ten patients with suspected gallbladder abnormalities. Our imaging sets produced high quality 3D images with excellent visualization in 70% (7/10) of all cases. Virtual laparoscopic imaging was also compared with other imaging techniques and imaging using helical scans can proved useful in preoperative imaging. Furthermore, virtual laparoscopic imaging using helical scans can in surgical planning and serve as a visual aid in discussions between radiologists, surgeons, and patients. (author)

  11. An automatic approach for 3D registration of CT scans

    Science.gov (United States)

    Hu, Yang; Saber, Eli; Dianat, Sohail; Vantaram, Sreenath Rao; Abhyankar, Vishwas

    2012-03-01

    CT (Computed tomography) is a widely employed imaging modality in the medical field. Normally, a volume of CT scans is prescribed by a doctor when a specific region of the body (typically neck to groin) is suspected of being abnormal. The doctors are required to make professional diagnoses based upon the obtained datasets. In this paper, we propose an automatic registration algorithm that helps healthcare personnel to automatically align corresponding scans from 'Study' to 'Atlas'. The proposed algorithm is capable of aligning both 'Atlas' and 'Study' into the same resolution through 3D interpolation. After retrieving the scanned slice volume in the 'Study' and the corresponding volume in the original 'Atlas' dataset, a 3D cross correlation method is used to identify and register various body parts.

  12. Blind Analysis of CT Image Noise Using Residual Denoised Images

    CERN Document Server

    Roychowdhury, Sohini; Alessio, Adam

    2016-01-01

    CT protocol design and quality control would benefit from automated tools to estimate the quality of generated CT images. These tools could be used to identify erroneous CT acquisitions or refine protocols to achieve certain signal to noise characteristics. This paper investigates blind estimation methods to determine global signal strength and noise levels in chest CT images. Methods: We propose novel performance metrics corresponding to the accuracy of noise and signal estimation. We implement and evaluate the noise estimation performance of six spatial- and frequency- based methods, derived from conventional image filtering algorithms. Algorithms were tested on patient data sets from whole-body repeat CT acquisitions performed with a higher and lower dose technique over the same scan region. Results: The proposed performance metrics can evaluate the relative tradeoff of filter parameters and noise estimation performance. The proposed automated methods tend to underestimate CT image noise at low-flux levels...

  13. Neural network and its application to CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nikravesh, M.; Kovscek, A.R.; Patzek, T.W. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-02-01

    We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.

  14. Radiography, Bone Scan, and F-18 FDG PET/CT Imaging Findings in a Patient with Paget's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun Tae; Kim, Sung Eun [Korea University Guro Hospital, Seoul (Korea, Republic of)

    2010-04-15

    Background A 52-year-old female patient sought evaluation at our hospital for an incidental abnormal finding on an abdominal radiograph. The initial radiograph showed irregular sclerotic changes involving the right pelvic bone. At the same time, bone scintigraphy showed intense hot uptake in the right iliac and pubic bones. CT images showed characteristic thickening of the pelvic brim, suggesting the mixed phase of Paget's disease. The level of alkaline phosphatase (ALP) was 266 IU/I. {sup 18}F-FDG PET/CT images also showed diffusely increased {sup 18}F-FDG uptake in the right pelvic bone. However, the findings of {sup 18}F-FDG PET/CT were less notable than those of bone scintigraphy. We report the imaging findings of a patient with Paget's disease evaluated by radiography, bone scintigraphy, and {sup 18}F-FDG PET/CT.

  15. An experimental approach to improve the Monte Carlo modelling of offline PET/CT-imaging of positron emitters induced by scanned proton beams

    Science.gov (United States)

    Bauer, J.; Unholtz, D.; Kurz, C.; Parodi, K.

    2013-08-01

    We report on the experimental campaign carried out at the Heidelberg Ion-Beam Therapy Center (HIT) to optimize the Monte Carlo (MC) modelling of proton-induced positron-emitter production. The presented experimental strategy constitutes a pragmatic inverse approach to overcome the known uncertainties in the modelling of positron-emitter production due to the lack of reliable cross-section data for the relevant therapeutic energy range. This work is motivated by the clinical implementation of offline PET/CT-based treatment verification at our facility. Here, the irradiation induced tissue activation in the patient is monitored shortly after the treatment delivery by means of a commercial PET/CT scanner and compared to a MC simulated activity expectation, derived under the assumption of a correct treatment delivery. At HIT, the MC particle transport and interaction code FLUKA is used for the simulation of the expected positron-emitter yield. For this particular application, the code is coupled to externally provided cross-section data of several proton-induced reactions. Studying experimentally the positron-emitting radionuclide yield in homogeneous phantoms provides access to the fundamental production channels. Therefore, five different materials have been irradiated by monoenergetic proton pencil beams at various energies and the induced β+ activity subsequently acquired with a commercial full-ring PET/CT scanner. With the analysis of dynamically reconstructed PET images, we are able to determine separately the spatial distribution of different radionuclide concentrations at the starting time of the PET scan. The laterally integrated radionuclide yields in depth are used to tune the input cross-section data such that the impact of both the physical production and the imaging process on the various positron-emitter yields is reproduced. The resulting cross-section data sets allow to model the absolute level of measured β+ activity induced in the investigated

  16. Standard Splenic Volume Estimation in North Indian Adult Population: Using 3D Reconstruction of Abdominal CT Scan Images

    Directory of Open Access Journals (Sweden)

    Adil Asghar

    2011-01-01

    Full Text Available A prospective study was carried out to establish normative data for splenic dimensions in North Indian population and their correlation with physical standard on abdominal CT of 21 patients aged between 20 and 70 years having no splenic disorders. Splenic volume was measured by two methods—volume and surface rendering technique of Able 3D doctor software and prolate ellipsoid formula. Volumes measured by both the techniques were correlated with their physical standards. Mean splenic volume was 161.57±90.2 cm3 and range 45.7–271.46 cm3. The volume of spleen had linear correlation with body height (r=0.512, P<.05. Splenic volume (cm3 = 7 × height (cm − 961 can be used to generate normal standard volume of spleen as a function of body height in North Indian population (with 95% confidence interval. This formula can be used to objectively measure the size of the spleen in adults who have clinically suspected splenomegaly.

  17. CT scan correlates of gesture recognition.

    Science.gov (United States)

    Ferro, J M; Martins, I P; Mariano, G; Caldas, A C

    1983-10-01

    The ability to recognise gestures was studied in 65 left-hemispheric stroke patients whose lesions were located by CT scan. In the acute stage (first month) frontal lobe and basal ganglia were frequently involved in patients showing inability to recognise gestures. In the later (third to fourth month) and chronic stages (greater than 6 months) parietal lobe involvement was important; lesions causing gesture recognition impairment were larger, had more extensive and frequent parietal involvement and produced less temporal lobe damage than those causing aural comprehension defects. These findings are discussed in the light of recent models of cerebral localisation of complex functions.

  18. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans,

  19. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, a

  20. Acquired tracheomalacia: detection by expiratory CT scan.

    Science.gov (United States)

    Aquino, S L; Shepard, J A; Ginns, L C; Moore, R H; Halpern, E; Grillo, H C; McLoud, T C

    2001-01-01

    The purpose of this work was to determine whether cross-sectional area and coronal and sagittal diameter measurements of the trachea between inspiration and end-expiration on CT are significantly different between patients with acquired tracheomalacia and those without this condition. Inspiratory and end-expiratory CT scans of the trachea of 23 normal patients and 10 patients with acquired tracheomalacia were analyzed. Percent changes in cross-sectional area, coronal, and sagittal diameters were calculated. For patients with tracheomalacia, mean percent changes in the upper and middle trachea between inspiration and expiration were 49 and 44%; mean changes in the coronal and sagittal diameters in the upper and middle tracheal were 4 and 10% and 39 and 54%, respectively. Control group mean percent changes in the upper and middle tracheal area were 12 and 14%, respectively, and mean changes in the coronal and sagittal diameters in the upper and middle trachea were 4 and 4% and 11 and 13%, respectively. Significant differences were calculated for changes in cross-sectional area and sagittal diameter between groups (p 18% change in the upper trachea and 28% change in the midtrachea between inspiration and expiration were observed; the probability of tracheomalacia was 89-100%. The probability of tracheomalacia was > 89%, especially if the change in sagittal diameter was > 28%. By measuring changes in tracheal cross-sectional area and sagittal diameters between inspiratory and end-expiratory CT, a significant difference can be identified between normal patients and those with acquired tracheomalacia.

  1. Diagnosis of pituitary microadenomas by CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Sakoda, K.; Gen, M.; Yonezawa, M.; Ohta, M.; Matsumura, S. (Hiroshima Univ. (Japan). School of Medicine)

    1981-10-01

    The presence of pituitary microadenomas can be established by the detection of minor changes on polytomograms of the sella turcica. However, as this method is a procedure for detecting secondary changes due to adenoma, it is understandable that microadenomas which fail to present secondary changes cannot be picked up. From this point of view, we investigated the possibility detecting changes in the pituitary itself by means of CT. An axial scan of pituitary microadenomas by EMI-1010 showed that some of the PRL secreting adenomas and all of the GH secreting adenomas showed areas of high density, and that some of PRL secreting adenomas and all the ACTH secreting adenomas showed areas of low density at the site of the adenomas. On a coronal scan with GE/X2, the normal pituitary is highly enhanced, and an absorption coefficient of 70 - 80 is demonstrated, but on an axial scan the coefficient becomes 25 - 35 due to the partial-volume effect. On a coronal scan pituitary microadenomas are shown as hypodense-lucent or isodense as a normal pituitary. However, the absorption coefficient of the hypodense-lucent area was 50 - 60; this is not low, but is, rather, a high density. At present, it is our belief that it is most effective to use a coronal angle with a high-resolution scanner in the diagnosis of pituitary microadenomas.

  2. Dose versus image quality in multidetector CT scanning: a methodology for acquisition protocols optimization;Dose versus qualite image en TDM multidetecteur: une methodologie pour l'optimisation des protocoles d'acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Bonniaud, G.; Tran Dinh, V.; Texier, N.; Touati, R.; Simon, J.; Roger, P.

    2009-10-15

    Objective: to determine the influence of acquisition and reconstruction parameters on the dose and the image quality in multi detectors CT scanning to optimize the protocols. As conclusion: The optimization allowed to reduce, in average, the weighted computed tomography dose index-vol (wC.T.D.I.vol) of 20% through the pitch increase, the use of the broadest collimation and/or the use of a retrospectively reconstruction (zoom factor and/or increase matrix size) without deteriorating the noise and/or resolution performances more than 10%. (N.C.)

  3. Colitis detection on abdominal CT scans by rich feature hierarchies

    Science.gov (United States)

    Liu, Jiamin; Lay, Nathan; Wei, Zhuoshi; Lu, Le; Kim, Lauren; Turkbey, Evrim; Summers, Ronald M.

    2016-03-01

    Colitis is inflammation of the colon due to neutropenia, inflammatory bowel disease (such as Crohn disease), infection and immune compromise. Colitis is often associated with thickening of the colon wall. The wall of a colon afflicted with colitis is much thicker than normal. For example, the mean wall thickness in Crohn disease is 11-13 mm compared to the wall of the normal colon that should measure less than 3 mm. Colitis can be debilitating or life threatening, and early detection is essential to initiate proper treatment. In this work, we apply high-capacity convolutional neural networks (CNNs) to bottom-up region proposals to detect potential colitis on CT scans. Our method first generates around 3000 category-independent region proposals for each slice of the input CT scan using selective search. Then, a fixed-length feature vector is extracted from each region proposal using a CNN. Finally, each region proposal is classified and assigned a confidence score with linear SVMs. We applied the detection method to 260 images from 26 CT scans of patients with colitis for evaluation. The detection system can achieve 0.85 sensitivity at 1 false positive per image.

  4. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  5. RONI Based Secured and Authenticated Indexing of Lung CT Images.

    Science.gov (United States)

    Jasmine Selvakumari Jeya, I; Suganthi, J

    2015-01-01

    Medical images need to be transmitted with the patient's information without altering the image data. The present paper discusses secured indexing of lung CT image (SILI) which is a secured way of indexing the lung CT images with the patient information. Authentication is provided using the sender's logo information and the secret key is used for embedding the watermark into the host image. Watermark is embedded into the region of Noninterest (RONI) of the lung CT image. RONI is identified by segmenting the lung tissue from the CT scan image. The experimental results show that the proposed approach is robust against unauthorized access, noise, blurring, and intensity based attacks.

  6. Dynamic CT myocardial perfusion imaging.

    Science.gov (United States)

    Caruso, Damiano; Eid, Marwen; Schoepf, U Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie; Spandorfer, Adam; Laghi, Andrea; De Cecco, Carlo N

    2016-10-01

    Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  7. Thoracic CT

    Science.gov (United States)

    ... lungs; CT scan - chest Images CT scan Thyroid cancer - CT scan Pulmonary nodule, solitary - CT scan Lung mass, right upper ... Chest Injuries and Disorders CT Scans Emphysema Lung Cancer Lung Diseases Pleural Disorders Pneumonia Pulmonary Embolism Tuberculosis Browse the Encyclopedia A.D.A. ...

  8. The Beatles, the Nobel Prize, and CT scanning of the chest.

    Science.gov (United States)

    Goodman, Lawrence R

    2010-01-01

    From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.

  9. Optimized Temporal Window for Detection and Characterization of Renal Cell Carcinomas with Dynamic CT Scanning

    Institute of Scientific and Technical Information of China (English)

    Jinhong Wang; Peijun Wang; Xiaohu Zhao; Xinqin Mao; Xiaolong Gao; Jun Liu

    2005-01-01

    OBJECTIVE To investigate the optimized time period for detection and characterization of renal cell carcinomas (RCC) when the specific CT features appear during spiral dynamic CT scanning, and to optimize an effective scanning protocol of spiral CT for evaluating RCC.METHODS Twenty-four patients with RCC verified by pathology had undergone a dynamic CT (D-CT) scan. A plain scan was employed to select the target slice. Single-level dynamic scanning started at 14-17 s after the intravenous contrast media had been administered, with a scan interval of 4.9 s acquiring a total number of 17~24 frames. A regular CT scan of the whole kidney followed by a delayed single slice acquisition through the target slice in the excretory phase was performed. Images were assessed in two ways: (1) A group of experienced radiologists reviewed the CT images to find when the specific signs appeared and when the CT features of RCC were optimally displayed; (2) Data measurement of the time-density curves (T-DC) of RCC. The exact time was obtained when the densities of the tumor, renal parenchyma, medulla and aorta reached their peak enhancement, thus also the time when the density difference between tumor and parenchyma was at maximum (Max T-M). Based on the slope of the contrast media uptake curve, T-DC types were ranked from the smallest to the biggest of slope as type A, B and C.RESULTS 1. The review of the CT images by the radiologists showed that the CT features of RCC were optimally demonstrated at 70.2 s. The earliest time at which RCC CT features were examined was at 23.9 s. 2. Image data analysis: the time that the density (or CT value) of the tumor mass reached peak enhancement was at 54 s and peak value was at 80.4 Hu for RCC. The time of the maximal difference of densities between tumor and renal parenchyma was at 102 s.CONCLUSION The following proposal is the scanning protocol for detecting RCC recommended by our research: After a plain scan to determine the target level, a

  10. 护理质量对PET-CT检查成像质量的影响及处理对策%Effect of Nursing Quality on the Image Quality of PET-CT Scanning and Management Strategy

    Institute of Scientific and Technical Information of China (English)

    李红; 郑凯; 李海英; 王云华

    2014-01-01

    To explore the effect of nursing quality on the image quality of PET-CT scanning .[Methods] The nursing factors such as the preparation before examination ,drug injection method and doctor's advice after injection in 57 patients receiving PET-CT scanning were analyzed .The success rate of PET-CT scanning was calculated .The nursing factor affecting the image quality was analyzed .[Results] The success rate of 57 patients was 100% .There were 44 cases(77 .2% ) with 1st image ,9 cases(15 .8% ) with 2nd image , 4 cases(7% ) with 3rd image and 0 case with 4th image .The influential factors of poor PET-CT image included over high physiogenic aggregation in enteric cavity caused by insufficient hydration in intestinal tract of 9 cases in which 18F-FDG uptake in digestive tract of 4 cases was obviously decreased after receiving the delayed scan-ning ,and 3 cases had abnormal increased glucose metabolism due to tracer leakage ,and 1 case had urine con-tamination ,and 1 case had poor concordance between PET and CT image .[Conclusion] Nursing quality can directly affect the quality of PET-CT scanning .Controlling blood sugar level ,strengthening mental nursing for patients ,taking sufficient intestinal hydration ,avoiding drug injection leakage ,advising patients to refrain from contamination of clothes and skin by urine and properly using the sedative for dysphoria patients are very important to improve the quality of PET-CT image .%【目的】探讨护理质量对正电子发射断层成像-X线计算机断层成像(PET-CT )检查成像质量的影响。【方法】对57例PET-CT检查患者采用检查前准备、药物注射方法、注药后候诊医嘱等护理因素,统计检查成功率、并分析影响图像质量的护理因素。【结果】57例检查成功率100%,其中图片质量以甲、乙、丙、丁判定分别占44例(77.2%)、9例15.8%、4例(7%)与0例。PET-CT图像质量欠佳中数据采集与图像扫描前肠道水化

  11. 'Ready-access' CT imaging for an orthopaedic trauma clinic.

    LENUS (Irish Health Repository)

    Cawley, D

    2011-03-01

    \\'Ready-Access\\' to CT imaging facilities in Orthopaedic Trauma Clinics is not a standard facility. This facility has been available at the regional trauma unit, in Merlin Park Hospital, Galway for the past four years. We reviewed the use of this facility over a 2-year period when 100 patients had CT scans as part of their trauma clinic assessment. The rate of CT scan per clinic was 0.6. The mean waiting time for a CT scan was 30 minutes. 20 (20%) new fractures were confirmed, 33 (33%) fractures were out-ruled, 25 (25%) fractures demonstrated additional information and 8 (8%) had additional fractures. 20 (20%) patients were discharged and 12 (12%) patients were admitted as a result of the CT scan. It adds little time and cost to CT scanning lists.

  12. Segmentation of anatomical structures in chest CT scans

    NARCIS (Netherlands)

    van Rikxoort, E.M.

    2009-01-01

    In this thesis, methods are described for the automatic segmentation of anatomical structures from chest CT scans. First, a method to segment the lungs from chest CT scans is presented. Standard lung segmentation algorithms rely on large attenuation differences between the lungs and the surrounding

  13. Automatic segmentation of pulmonary segments from volumetric chest CT scans.

    NARCIS (Netherlands)

    Rikxoort, E.M. van; Hoop, B. de; Vorst, S. van de; Prokop, M.; Ginneken, B. van

    2009-01-01

    Automated extraction of pulmonary anatomy provides a foundation for computerized analysis of computed tomography (CT) scans of the chest. A completely automatic method is presented to segment the lungs, lobes and pulmonary segments from volumetric CT chest scans. The method starts with lung segmenta

  14. Dual energy CT with one full scan and a second sparse-view scan using structure preserving iterative reconstruction (SPIR)

    Science.gov (United States)

    Wang, Tonghe; Zhu, Lei

    2016-09-01

    Conventional dual-energy CT (DECT) reconstruction requires two full-size projection datasets with two different energy spectra. In this study, we propose an iterative algorithm to enable a new data acquisition scheme which requires one full scan and a second sparse-view scan for potential reduction in imaging dose and engineering cost of DECT. A bilateral filter is calculated as a similarity matrix from the first full-scan CT image to quantify the similarity between any two pixels, which is assumed unchanged on a second CT image since DECT scans are performed on the same object. The second CT image from reduced projections is reconstructed by an iterative algorithm which updates the image by minimizing the total variation of the difference between the image and its filtered image by the similarity matrix under data fidelity constraint. As the redundant structural information of the two CT images is contained in the similarity matrix for CT reconstruction, we refer to the algorithm as structure preserving iterative reconstruction (SPIR). The proposed method is evaluated on both digital and physical phantoms, and is compared with the filtered-backprojection (FBP) method, the conventional total-variation-regularization-based algorithm (TVR) and prior-image-constrained-compressed-sensing (PICCS). SPIR with a second 10-view scan reduces the image noise STD by a factor of one order of magnitude with same spatial resolution as full-view FBP image. SPIR substantially improves over TVR on the reconstruction accuracy of a 10-view scan by decreasing the reconstruction error from 6.18% to 1.33%, and outperforms TVR at 50 and 20-view scans on spatial resolution with a higher frequency at the modulation transfer function value of 10% by an average factor of 4. Compared with the 20-view scan PICCS result, the SPIR image has 7 times lower noise STD with similar spatial resolution. The electron density map obtained from the SPIR-based DECT images with a second 10-view scan has an

  15. Discordant Findings of Skeletal Metastasis Between Tc99m MDP Bone Scans and F18 FDG PET/CT Imaging for Advanced Breast and Lung Cancers—Two Case Reports and Literature Review

    Directory of Open Access Journals (Sweden)

    Yu-Wen Chen

    2007-12-01

    Full Text Available Traditionally, Tc99m methyl diphosphate (MDP bone scintigraphy provides high-sensitivity detection of skeletal metastasis from breast and lung cancers in regular follow-up. Fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT, based on the glucose metabolism of malignant cells, plays a role in describing rumor growth, proliferation of neoplasm and the extent of metastasis. In general, concordant findings of skeletal metastasis are seen on both types of image, especially in cases of breast and lung cancer. However, there were extremely discordant findings of skeletal metastasis between bone scans and F18 FDG PET/CT imaging in two cases among 300 consecutive F18 FDG PET/CT follow-up exams of patients with malignancies, during the past year, in our center. Both cases, one of breast cancer and one of lung cancer, had negative bone scintigraphic findings, but a diffusely high grade of F18 FDG avid marrow infiltration in the axial spine, leading to the diagnosis of stage IV disease in both cases. Owing to variant genetic aberrance of malignance, F18 FDG PET/CT reveals direct evidence of diffuse, rapid neoplasm metabolism in the bone marrow of the spine, but not of secondary osteoblastic reactions in vivo. F18 FDG PET/CT should always be employed in the follow-up of patients with malignancies.

  16. An Effort to Develop an Algorithm to Target Abdominal CT Scans for Patients After Gastric Bypass.

    Science.gov (United States)

    Pernar, Luise I M; Lockridge, Ryan; McCormack, Colleen; Chen, Judy; Shikora, Scott A; Spector, David; Tavakkoli, Ali; Vernon, Ashley H; Robinson, Malcolm K

    2016-10-01

    Abdominal CT (abdCT) scans are frequently ordered for Roux-en-Y gastric bypass (RYGB) patients presenting to the emergency department (ED) with abdominal pain, but often do not reveal intra-abdominal pathology. We aimed to develop an algorithm for rational ordering of abdCTs. We retrospectively reviewed our institution's RYGB patients presenting acutely with abdominal pain, documenting clinical and laboratory data, and scan results. Associations of clinical parameters to abdCT results were examined for outcome predictors. Of 1643 RYGB patients who had surgery between 2005 and 2015, 355 underwent 387 abdCT scans. Based on abdCT, 48 (12 %) patients required surgery and 86 (22 %) another intervention. No clinical or laboratory parameter predicted imaging results. Imaging decisions for RYGB patients do not appear to be amenable to a simple algorithm, and patient work-up should be based on astute clinical judgment.

  17. Comparison of image quality between axial and spiral scan mode in routine head CT%常规头部CT螺旋扫描与轴扫描模式的影像质量对照

    Institute of Scientific and Technical Information of China (English)

    傅强; 刘晓菲; 于虹; 徐克

    2012-01-01

    目的 通过头部CT螺旋扫描和轴扫描两种不同扫描模式的影像质量对照,探讨常规头部CT采用螺旋扫描模式取代轴扫描模式的可行性.方法 40例患者,其中男性24例,女性16例;年龄18 ~ 74岁,平均年龄46岁.分别接受头部CT螺旋扫描和轴扫描两种不同模式扫描,轴扫描参数:140 kV、170 mA用于颅底部;120 kV、150 mA用于颅脑部,每周2s.螺旋扫描参数:120 kV,150 mA,每周0.6 s.扫描剂量直接取自设备剂量指示值(CTDI和DLP).影像质量分别由2位专家采用双盲法,对头部CT的颅底、脑灰-白质层面及全部影像逐层进行CT值测量评估.结果 常规头部CT螺旋扫描模式较轴扫描模式可有效去除颅底部伪影,并能减少扫描时间和扫描剂量(轴扫描模式与螺旋扫描模式对比,CTDI 55.43 mGy/37.80 mGy;DLP 662.10 mGy· cm/498.28 mGy· cm;扫描时间12.0 s/7.2 s)(P< 0.001).结论 常规头部CT螺旋扫描模式的影像质量完全可与轴扫描模式相媲美,并可取代轴扫描模式.同时常规头部CT螺旋扫描模式还具有可减少扫描时间和辐射剂量,并可进行影像的二维和三维后处理,有利于提高微小病灶正确诊断率的优越性.%Objective To assess the feasibility of replacing axial CT scan mode with spiral CT scan mode in routine head CT through comparing the image quality between spiral and routine axial (sequential) acquired head CT. Methods A total of 40 cases were enrolled, male 24, female 16; aged 18 - 74 years old, mean age 46 years old. They were performed spiral scan and axial scan, respectively. Scan parameter axial mode were 140 kV, 170 mA for petrou bone, and 120 kV, 150 mA for brain, scan time 2.0 s/rol; and spiral mode were 120 kV, 150 mA, scan time 0.6 s/rol. Radiation dose were measured directly from the CT scan indicated computed tomography dose index (CTDI) and dose-length product (DLP). The image quality at the level of the posterior fossa and grey -white matter

  18. Possible Role of Meckel’s Scan Fused with SPECT CT Imaging: Unraveling the Cause of Abdominal Pain and Obscure-Overt Gastrointestinal Bleeding

    Directory of Open Access Journals (Sweden)

    D.Kim Turgeon

    2008-03-01

    Full Text Available A 27-year-old male presented with recurrent abdominal pain and high volume hematochezia despite undergoing extensive testing and a right hemicolectomy 3 years prior for a linear bleeding ulceration in the ascending colon. Studies at the University of Michigan included esophagogastroduodenoscopy (EGD, colonoscopy and video capsule endoscopy (VCE, revealing an arteriovenous malformation (AVM in the terminal ileum. He was hospitalized for recurrent symptoms. His presentation suggested a small bowel source of obscure-overt GI bleeding based on prior non-diagnostic colonoscopy and EGD and a bilious nasogastric lavage. Tagged red blood cell scan localized bleeding to the right lower quadrant. Colonoscopy showed fresh blood in the terminal ileum without a clear source. Angiography showed no evidence of bleeding or terminal ileal AVM. A novel Meckel’s scan fused with SPECT imaging showed focal uptake in the terminal ileum. The patient underwent Meckel’s diverticulectomy with sparing of adjacent bowel and has remained asymptomatic for 19 months. This case illustrates that patients with obscure-overt GI bleeding require a step-wise multi-modality diagnostic work-up. Because Meckel’s scans are false-positive in 28% of adults, Meckel’s scan fused with SPECT imaging may offer an approach to refine diagnostic accuracy of either scan alone, but requires further investigation. Exploratory laparotomy should be reserved as a last option and is best performed with intraoperative endoscopy.

  19. Dose calculation based on Cone Beam CT images

    DEFF Research Database (Denmark)

    Slot Thing, Rune

    , several other factors contributing to the image quality degradation, and while one should, theoretically, be able to obtain CT-like image quality from CBCT scans, clinical image quality is often very far from this ideal realisation. The present thesis describes the investigation of potential image quality...... improvements in clinical CBCT imaging achieved through post-processing of the clinical image data. A Monte Carlo model was established to predict patient specific scattered radiation in CBCT imaging, based on anatomical information from the planning CT scan. This allowed the time consuming Monte Carlo......Cone beam CT (CBCT) imaging is frequently used in modern radiotherapy to ensure the proper positioning of the patient prior to each treatment fraction. With the increasing use of CBCT imaging for image guidance, interest has grown in exploring the potential use of these 3– or 4–D medical images...

  20. DentaScan in oral imaging

    Energy Technology Data Exchange (ETDEWEB)

    Au-Yeung, K.M.; Ahuja, A.T.; Ching, A.S.C.; Metreweli, C

    2001-09-01

    In the past, dental disease and lesions involving the jaw were either evaluated by plain radiography or tomography. The advent of spiral computed tomography (CT) and DentaScan is changing the imaging trend. It is now not only used for pre-implant assessment but also in the diagnosis of lesions affecting the jaw. This pictorial review discusses the role of DentaScan in the various abnormalities that may affect the mandible and maxilla. Au-Yeung, K.M. et al. (2001)

  1. Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation.

    Science.gov (United States)

    Park, Chan Kue; Choo, Ki Seok; Jeon, Ung Bae; Baik, Seung Kug; Kim, Yong Woo; Kim, Tae Un; Kim, Chang Won; Jeong, Yeon Ju; Jeong, Dong Wook; Lim, Soo Jin

    2013-06-01

    To compare vascular enhancement, image quality, and radiation dose of 128-slice dual-source CT venography (CTV) between an imaging setting of 120 kVp with low pitch, and a setting of 100 kVp combined with high pitch and automatic tube current modulation. A total of 100 patients with suspected deep vein thrombosis and varicose veins were divided into two groups: Group 1 [50 patients, 120 kVp, low pitch (0.6), and fixed 120 mA) and Group 2 (50 patients, 100 kVp, high pitch (3.0), and automatic tube current modulation]. Two radiologists, who were blinded to the image protocol, assessed vascular enhancement and image noise in the inferior vena cava (IVC), femoral vein, and popliteal vein. They also assigned an image quality score independently using a 5-point visual scale. Effective dose was estimated using the dose-length product (DLP). Group demographics, radiation dose, vascular enhancement, image noise, and image quality in the two groups were analyzed. Mean vascular enhancement of the IVC, femoral vein, and popliteal vein was significantly higher in group 2 than in group 1, and images in group 2 had significantly higher image noise. However, there were no significant differences in subjective image quality score of the IVC, femoral vein, and popliteal vein. The mean DLP in group 2 (402.10 ± 94.29 mGy cm) was significantly lower than that in group 1 (973.36 ± 63.20 mGy cm) (P enhancement with acceptable image quality and low radiation dose.

  2. Relationship between Hounsfield unit in CT scan and gray scale in CBCT

    Science.gov (United States)

    Kamaruddin, Noorshaida; Rajion, Zainul Ahmad; Yusof, Asilah; Aziz, Mohd Ezane

    2016-12-01

    Cone-beam computed tomography (CBCT) is an imaging system which has advantages over computed tomography (CT). Recently, CBCT has become widely used for oral and maxillofacial imaging. In CT scan, Hounsfield Unit (HU) is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value). The aim of the present (in vitro) study was to investigate the relationship between gray scale in CBCT and HU in CT scan. In this descriptive study, the anthropomorphic head phantom was scanned with CBCT and CT scanner. Gray scales and HUs were detected on images at the crown of the teeth, trabecular and cortical bone of mandible. The images were analyzed to obtain the gray scale value and HU value. The obtained value then used to investigate the relationship between CBCT gray scales and HUs. For the statistical analysis, t-test, Pearson's correlation and regression analysis were used. The differences between the gray scale of CBCT and HU of CT were statistically not significant, whereas the Pearson's correlation coefficients demonstrated a statistically significant correlation between gray scale of CBCT and HU of CT values. Considering the fact that gray scale in CBCT is important in pre assessment evaluation of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  3. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Liu, Q; Qiu, J; Zhuo, W [Institute of Radiation Medicine Fudan University, Shanghai (China); Majer, M; Knezevic, Z; Miljanic, S [Radiation Chemistry and Dosimetry Laboratory, Ruder Boskovic Institute, Zagreb (Croatia); Hrsak, H [Clinical Hospital Centre Zagreb, Zagreb (Croatia)

    2016-06-15

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

  4. CT scan findings in cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Udaka, Fukashi; Okuda, Bungo; Okada, Masako; Okae, Shunji; Kameyama, Masakuni (Chikamori Hospital, Kochi (Japan))

    1982-12-01

    Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies.

  5. Solitary pulmonary granuloma with marked enhancement on dynamic CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Stark, P.; Wong, V.; Gold, P.

    1988-10-01

    A patient is described who presented with a vividly enhancing solitary pulmonary nodule during dynamic CT scanning. This mass proved to represent a granuloma due to coccidioidomycosis. The presumptive mechanism of enhancement as well as the differential diagnosis are discussed.

  6. CT Scans Might Help Gauge Heart Attack Risk

    Science.gov (United States)

    ... html CT Scans Might Help Gauge Heart Attack Risk Researchers aim to identify vulnerable patients before damage becomes irreversible To use ... significantly narrowed, Antoniades said. No currently available test identifies ... journal Science Translational Medicine . About 750,000 Americans have ...

  7. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  8. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  9. Cervical spine evaluation in urban trauma centers: lowering institutional costs and complications through helical CT scan.

    Science.gov (United States)

    Grogan, Eric L; Morris, John A; Dittus, Robert S; Moore, Derek E; Poulose, Benjamin K; Diaz, Jose J; Speroff, Theodore

    2005-02-01

    In the evaluation of the cervical spine (c-spine), helical CT scan has higher sensitivity and specificity than plain radiographs in the moderate- and high-risk trauma population, but is more costly. We hypothesize that institutional costs associated with missed injuries make helical CT scan the least costly approach. A cost-minimization study was performed using decision analysis examining helical CT scan versus radiographic evaluation of the c-spine. Parameter estimates were obtained from the literature for probability of c-spine injury, probability of paralysis after missed injury, plain film sensitivity and specificity, CT scan sensitivity and specificity, and settlement cost of missed injuries resulting in paralysis. Institutional costs of CT scan and plain radiography were used. Sensitivity analyses tested robustness of strategy preference, accounted for parameter variability, and determined threshold values for individual parameters on strategy preference. C-spine evaluation with helical CT scan has an expected cost of US 554 dollars per patient compared with US 2,142 dollars for plain films. CT scan is the least costly alternative if threshold values exceed US 58,180 dollars for institutional settlement costs, 0.9% for probability of c-spine fracture, and 1.7% for probability of paralysis. Plain films are least costly if CT scan costs surpass US 1,918 dollars or plain film sensitivity exceeds 90%. Helical CT scan is the preferred initial screening test for detection of cervical spine fractures among moderate- to high-risk patients seen in urban trauma centers, reducing the incidence of paralysis resulting from false-negative imaging studies and institutional costs, when settlement costs are taken into account.

  10. [Direct total body CT scan in multi-trauma patients

    NARCIS (Netherlands)

    Sierink, J.C.; Saltzherr, T.P.; Edwards, M.J.R.; Beuker, B.J.; Patka, P.; Goslings, J.C.; studiegroep, R.

    2012-01-01

    BACKGROUND: Immediate total body computed tomography (CT) scanning has become important in the early diagnostic phase of trauma care because of its high diagnostic accuracy. However, literature provides limited evidence whether immediate total body CT leads to better clinical outcome then convention

  11. Value of CT scan in the diagnosis of primary large bowel lymphoma

    Institute of Scientific and Technical Information of China (English)

    赵修义; 张雪林; 王劲; 郑卫权; 文戈

    2003-01-01

    Objective:To study the CT imaging of primary large bowel lymphoma and evaluate the value of CT scan.Methods:CT reports of 8 patients with proven primary large bowel lymphoma were retrospectively reviewed.Plain CT scans were done on all patients,enhanced CT scans simultaneously with 5 - 10 mm section thickness,and 5 - 10 mm table increments in 6 cases.Results:Primary involved sites were on the cecum(n = 3),the ascending colon(n = 2),and the rectum(n = 1).The tumor was found in multiple areas of the large bowel in 2 cases.CT appearance fell into 3 typical patterns in our study.The first was focal mass type in 2 cases,with one combined with intussusception and retroperitoneal adenopathy; the second was segmental annular involvement type in 3 cases,with one of them combined with mesenteric adenopathy; the last was diffuse involvement type in 2 cases.Multiple nodules were seen in the rectum in 1 case.Conclusion:CT was found to be accurate in detecting the primary sites and complications of lymphoma,and evaluating invasion of adjacent structures; Focal mass type,segmental annular involvement type and diffuse involvement type are the main patterns of CT features in the primary large bowel lymphoma; The features revealed by CT scan are suggestive of primary large bowel lymphoma in some cases.

  12. Evaluation of Helical CT Scanning in Judging the Invasion and Metastasis of Gastric Carcinoma

    Institute of Scientific and Technical Information of China (English)

    GAOJianbo; KONGXiangquan; GUOHua; LIShuxin; YANGXuehua; LIYintai; ZHANGZhixu

    2004-01-01

    To determine the accuracy of triphase enhanced helical CT in judging the invasion and metastasis of gastric carcinoma, and to discuss the relation between imaging signs and pathological findings. Methods: Triphase enhanced helical CT scanning was performed in 46 patients with gastric carcinoma. Imaging findings were compared with postoperative pathologic results. Results: (1) The accuracy of helical CT for diagnosing involvement of tunica serosa, lymph node metastasis and distant metastasis was 84.8%, 87.0% and 100~ respectively. (2) CT signs of serosal involvement, lymph node metastasis and distant metastasis were in good accordance with pathological findings (P<0.05). Conclusion: Triphase enhanced helical CT scans can comprehensively and precisely reflect the pathologic characteristics of gastric carcinoma, thus it is a reliable technique for the diagnosis of this disease.

  13. Incidental finding of ovarian teratoma on post-therapy scan for papillary thyroid cancer and impact of SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jammah, Anwar Ali, E-mail: dranwarjammah@hotmail.com [Department of Medicine, King Saud University, Riyadh (Saudi Arabia); Driedger, Albert; Rachinsky, Irina [Department of Nuclear Medicine, University of Western Ontario, (Canada)

    2011-10-15

    A 41-year old woman post thyroidectomy and neck dissection is presented in this case. She initially presented goiter and an enlarged cervical lymph node. She had no family history of cancer or radiation therapy. She had total thyroidectomy and found to have papillary thyroid cancer (T4N1M0). Histopathology report revealed multifocal classical papillary thyroid carcinoma with lymphovascular invasion, extra-thyroidal extension, and positive lymph nodes. She was treated with 6.5 Gigabecquerel (GBq) of {sup 131}Iodine. Whole-body scan showed uptake in the neck and large focus in the left lower abdomen. Single-photon emission computed tomography SPECT/CT demonstrated a round shaped mass in the left pelvis. Pathology revealed cystic teratoma with benign thyroid tissue (struma ovarii), and no malignancy. Two months later, she had the second treatment with 5.5 GBq {sup 131}Iodine. Her follow-up stimulated and non-stimulated thyroglobulin levels were significantly lower, and there was no abnormal uptake in the follow- -up scan (author)

  14. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  15. Abdominal CT scanning in critically ill surgical patients.

    Science.gov (United States)

    Norwood, S H; Civetta, J M

    1985-01-01

    Clinical parameters, intensive care unit (ICU) course, abdominal computed tomography (CT) scans, and the clinical decisions of 53 critically ill patients were reviewed to determine the influence of the CT scan. No scans were positive before the eighth day. Sensitivity was 48% and specificity, 64%. Seventeen (23%) scans of the 72 provided beneficial results: eight localized abscesses that were drained; nine were negative and not operated on. Five (7%) scans provided detrimental information: scan negative with abscess discovered or scan positive but negative laparotomy. Fifty (70%) scans were either of no help or not used in management. The mortality rate was 50% when CT led to an intervention, and 47% in the entire group. Hospital charges were +33,408. Personnel time and cost were 497 hours and +3658; of the total +37,066, 77% (+28,541) could be considered wasted. From these data, it was concluded that CT scans should be used to confirm abscesses, not to search for a source of sepsis. PMID:4015222

  16. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  17. Quality assurance of CT scanning for industrial applications

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch

    ClassWeb through volume comparisons to real dissections of pig carcasses. For the real dissections, volumes of tissue types such as bone, lean meat and fat, are estimated using commercial VolumeGraphics software. It is detected that the ANOVA and the residuals from the virtual dissection fail the normality test...... to 158 μm, compared to average uncertainties below 5.5 μm using CMMs. A test was performed to check if X-ray contrast modalities can be applied for metrological purposes. Traditionally, segmentation between multi-materials in CT scanning is done by using different edge detection techniques and threshold...... to 1348 mL, compared to average uncertainties below 10 mL using the gravimetric method. DMRI and DTU Compute have previously developed advanced image analysis software (PigClassWeb) which performs virtual dissections in pig carcasses. A DOE was carried out to document the performance of Pig...

  18. Fast CT-CT fluoroscopy registration with respiratory motion compensation for image-guided lung intervention

    Science.gov (United States)

    Su, Po; Xue, Zhong; Lu, Kongkuo; Yang, Jianhua; Wong, Stephen T.

    2012-02-01

    CT-fluoroscopy (CTF) is an efficient imaging method for guiding percutaneous lung interventions such as biopsy. During CTF-guided biopsy procedure, four to ten axial sectional images are captured in a very short time period to provide nearly real-time feedback to physicians, so that they can adjust the needle as it is advanced toward the target lesion. Although popularly used in clinics, this traditional CTF-guided intervention procedure may require frequent scans and cause unnecessary radiation exposure to clinicians and patients. In addition, CTF only generates limited slices of images and provides limited anatomical information. It also has limited response to respiratory movements and has narrow local anatomical dynamics. To better utilize CTF guidance, we propose a fast CT-CTF registration algorithm with respiratory motion estimation for image-guided lung intervention using electromagnetic (EM) guidance. With the pre-procedural exhale and inhale CT scans, it would be possible to estimate a series of CT images of the same patient at different respiratory phases. Then, once a CTF image is captured during the intervention, our algorithm can pick the best respiratory phase-matched 3D CT image and performs a fast deformable registration to warp the 3D CT toward the CTF. The new 3D CT image can be used to guide the intervention by superimposing the EM-guided needle location on it. Compared to the traditional repetitive CTF guidance, the registered CT integrates both 3D volumetric patient data and nearly real-time local anatomy for more effective and efficient guidance. In this new system, CTF is used as a nearly real-time sensor to overcome the discrepancies between static pre-procedural CT and the patient's anatomy, so as to provide global guidance that may be supplemented with electromagnetic (EM) tracking and to reduce the number of CTF scans needed. In the experiments, the comparative results showed that our fast CT-CTF algorithm can achieve better registration

  19. The preliminary study of dentition surface reconstruction from CT scans and cast scanning image%根据CT扫描数据及印模三维重建牙列数字模型精度的初步研究

    Institute of Scientific and Technical Information of China (English)

    孙力; 郭亚娟; 赵妍; 李鸿波; 储冰峰

    2011-01-01

    目的:评价根据CT扫描数据和牙列印模重建牙列数字模型的精度.方法:以OKIO-V-100三维光学扫描系统扫描猴牙列标本获取标准模型;根据螺旋CT、锥柬CT扫描数据重建颌骨及牙列三维数字模型;制取猴牙列标本印模,灌制石膏模型,通过OKIO-V-100三维光学扫描系统扫描重建牙列形态.分别将CT扫描重建的数字图像、石膏模型扫描重建图像与标准模型的牙列图像拟合.拟合图像中使用不同颜色标记不同大小的误差值,并生成误差直方图.在拟合图像中以模拟平面截取牙列形态,分析不同位置的平面所截取的牙列数字模型与标准模型的体积之差及RVD/vs.结果:根据螺旋CT、锥束CT扫描数据重建牙列三维数字模型的RVD/vs可达40%以上,随着模拟平面龈向移动,RVD/vs有变小的趋势;再根据石膏模型扫描重建的模型中,随着模拟平面龈向移动,RVD/vs有变大的趋势.结论:根据螺旋CT、锥束CT扫描图像重建的牙列数字模型,与标准模型相比都有较大程度的放大,不同位置的平面所截取牙列图像的变形程度是不一致的,CT扫描与印模相结合重建三维牙颌模型可能是获得较高精度三维牙颌数字模型的方法.%Objective: The aim of this study was to evaluate the dimensional accuracy of dentition image reconstruction from CT scans and east scanning image. Methods: A simian dental arch was prepared and digitized as the standard model using OKIO-V-100 3D optical scanner. Impression was made for stone cast using silicone impression material, and the cast was digitized using the optical scanner. Dentition images were also reconstructed from spiral CT and cone-beam CT scans. The dentition images from impression and CT were superimposed onto the standard image. Distribution patterns of dimensional discrepancy were presented using histogram and different colors. The superimposed images were cut using different cross-section. The RVDVS was

  20. Computer-Aided Diagnosis with Deep Learning Architecture: Applications to Breast Lesions in US Images and Pulmonary Nodules in CT Scans

    Science.gov (United States)

    Cheng, Jie-Zhi; Ni, Dong; Chou, Yi-Hong; Qin, Jing; Tiu, Chui-Mei; Chang, Yeun-Chung; Huang, Chiun-Sheng; Shen, Dinggang; Chen, Chung-Ming

    2016-04-01

    This paper performs a comprehensive study on the deep-learning-based computer-aided diagnosis (CADx) for the differential diagnosis of benign and malignant nodules/lesions by avoiding the potential errors caused by inaccurate image processing results (e.g., boundary segmentation), as well as the classification bias resulting from a less robust feature set, as involved in most conventional CADx algorithms. Specifically, the stacked denoising auto-encoder (SDAE) is exploited on the two CADx applications for the differentiation of breast ultrasound lesions and lung CT nodules. The SDAE architecture is well equipped with the automatic feature exploration mechanism and noise tolerance advantage, and hence may be suitable to deal with the intrinsically noisy property of medical image data from various imaging modalities. To show the outperformance of SDAE-based CADx over the conventional scheme, two latest conventional CADx algorithms are implemented for comparison. 10 times of 10-fold cross-validations are conducted to illustrate the efficacy of the SDAE-based CADx algorithm. The experimental results show the significant performance boost by the SDAE-based CADx algorithm over the two conventional methods, suggesting that deep learning techniques can potentially change the design paradigm of the CADx systems without the need of explicit design and selection of problem-oriented features.

  1. Dual energy CT: New horizon in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Goo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  2. Dual-Energy CT: New Horizon in Medical Imaging.

    Science.gov (United States)

    Goo, Hyun Woo; Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  3. Knowledge Representation Of CT Scans Of The Head

    Science.gov (United States)

    Ackerman, Laurens V.; Burke, M. W.; Rada, Roy

    1984-06-01

    We have been investigating diagnostic knowledge models which assist in the automatic classification of medical images by combining information extracted from each image with knowledge specific to that class of images. In a more general sense we are trying to integrate verbal and pictorial descriptions of disease via representations of knowledge, study automatic hypothesis generation as related to clinical medicine, evolve new mathematical image measures while integrating them into the total diagnostic process, and investigate ways to augment the knowledge of the physician. Specifically, we have constructed an artificial intelligence knowledge model using the technique of a production system blending pictorial and verbal knowledge about the respective CT scan and patient history. It is an attempt to tie together different sources of knowledge representation, picture feature extraction and hypothesis generation. Our knowledge reasoning and representation system (KRRS) works with data at the conscious reasoning level of the practicing physician while at the visual perceptional level we are building another production system, the picture parameter extractor (PPE). This paper describes KRRS and its relationship to PPE.

  4. Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2014-06-01

    Full Text Available Background and aims. Cone-beam computed tomography (CBCT is an imaging system which has many advantages over computed tomography (CT. In CT scan, Hounsfield Unit (HU is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value. The aim of the present study was to investigate the relationship between gray scale in CBCT and Hounsfield Unit (HU in CT scan. Materials and methods. In this descriptive study, the head of a sheep was scanned with 3 CBCT and one medical CT scanner. Gray scales and HUs were detected on images. Reconstructed data were analyzed to investigate relationship between CBCT gray scales and HUs. Results. A strong correlation between gray scales of CBCT and HUs of CT scan was determined. Conclusion. Considering the fact that gray scale in CBCT is the criteria in measurement of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  5. Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT.

    Science.gov (United States)

    Razi, Tahmineh; Niknami, Mahdi; Alavi Ghazani, Fakhri

    2014-01-01

    Background and aims. Cone-beam computed tomography (CBCT) is an imaging system which has many advantages over computed tomography (CT). In CT scan, Hounsfield Unit (HU) is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value). The aim of the present study was to investigate the relationship between gray scale in CBCT) and Hounsfield Unit (HU) in CT scan. Materials and methods. In this descriptive study, the head of a sheep was scanned with 3 CBCT and one medical CT scanner. Gray scales and HUs were detected on images. Reconstructed data were analyzed to investigate relationship between CBCT gray scales and HUs. Results. A strong correlation between gray scales of CBCT and HUs of CT scan was determined. Conclusion. Considering the fact that gray scale in CBCT is the criteria in measurement of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  6. Size variation and collapse of emphysema holes at inspiration and expiration CT scan: evaluation with modified length scale method and image co-registration

    Directory of Open Access Journals (Sweden)

    Oh SY

    2017-07-01

    Full Text Available Sang Young Oh,1,* Minho Lee,1,* Joon Beom Seo,1,* Namkug Kim,1,2,* Sang Min Lee,1 Jae Seung Lee,3 Yeon Mok Oh3 1Department of Radiology, 2Department of Convergence Medicine, 3Department of Pulmonology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea *These authors contributed equally to this work Abstract: A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT. Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method (r-values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942. The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT parameters using the Pearson’s correlation test. The mean extents of low-attenuation area (LAA, E1 (<1.5 mm, E2 (<7 mm, E3 (<15 mm, and E4 (≥15 mm were 25.9%, 3.0%, 11.4%, 7.6%, and 3.9%, respectively, at the inspiratory CT, and 15.3%, 1.4%, 6.9%, 4.3%, and 2.6%, respectively at the expiratory CT. The extents of LAA, E2, E3, and E4 were found to be significantly correlated with the PFT ­parameters (r=−0.53, −0.43, −0.48, and −0.25, with forced expiratory volume in 1 second (FEV1; −0.81, −0.62, −0.75, and

  7. An evaluation of cranial CT scanning in clinical psychiatry.

    Science.gov (United States)

    Colohan, H; O'Callaghan, E; Larkin, C; Waddington, J L

    1989-07-01

    From 6,300 psychiatric admissions over a 37 month period, all 54 patient referrals for CT were identified and their charts reviewed. CT influenced diagnosis, management or prognosis in 11.7 percent of patients scanned. There was poor correlation between organicity on CT scan and findings on physical examination, laboratory testing, EEG and psychological testing. The mental state examination was the single significant correlate of CT abnormality. We suggest that the use of a formalised mental state examination such as the Mini Mental State, in addition to the usual clinical assessment of mental state, may improve the accuracy of prediction of abnormality on CT scan. The introduction of X-ray computed tomography (CT) is recognised to be one of the most important innovations in the recent history of clinical medicine. In neurology the value of a non-invasive technique for examining the intracranial contents was quickly realised in the areas of diagnosis, particularly in the detection of vascular accidents and tumours. CT has also attained a significant place in psychiatry. In research studies, it has provided important information on schizophrenia, alcoholism and chronic organic reactions. The place of CT in clinical psychiatry is less clear. As its availability has increased, such scans are being requested with increasing frequency in psychiatric patients. Cranial CT is a highly sensitive diagnostic procedure which, when used unselectively, may result in the discovery of incidental findings. Until recently, a function of the psychiatrist in relation to diagnosis was to first seek to distinguish symptoms produced by organic pathology from those produced by functional illness.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Thin-section CT scan of the pituitary gland

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, T.; Inoue, Y.; Taniguchi, S. (Osaka City Univ. (Japan). Faculty of Medicine)

    1982-02-01

    Topographic anatomy of the pituitary fossa was studied by 2 mm thin-section CT scan (Somatom II). Nineteen with normal pituitary (control group) and 20 with suspected pituitary abnormality were selected. Plain and contrast CT were performed in all cases. Contrast CT was carried out immediately after the rapid infusion of 220 ml of 30% iodinated contrast medium. In all of control group but two, pituitary gland was detected as homogeneous density and its density was the same as the density of normal brain tissues, and was enhanced in degree of about 25 CT number. In 2 cases, small low density was visualized in the pituitary gland. Pituitary gland was differentiated from cavernous sinus was usually higher than the pituitary gland. In the abnormal group, microadenoma of the pituitary gland was diagnosed in 5 cases and 3 out of 5 cases was proved by surgery. All 3 microadenomas proved slightly dense by plain CT and enhanced higher than normal pituitary gland by contrast CT. Polytomograms showed no abnormality of the sella turcica in one of these 3 cases. Although 3 microadenomas were detected by the abnormal enhancement, we are not sure whether all microadenoma can be detected by CT alone. Arachnoid herniation into the pituitary fossa was diagnosed in 7 of the control group and 2 of the abnormal group. Four out of these 9 cases were verified by using Metrizamide CT. By plain thin-section CT, the diagnosis of arachnoid herniation seems to be possible without Metrizamide CT.

  9. Scanning Terahertz Heterodyne Imaging Systems

    Science.gov (United States)

    Siegel, Peter; Dengler, Robert

    2007-01-01

    Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

  10. RONI Based Secured and Authenticated Indexing of Lung CT Images

    Directory of Open Access Journals (Sweden)

    I. Jasmine Selvakumari Jeya

    2015-01-01

    Full Text Available Medical images need to be transmitted with the patient’s information without altering the image data. The present paper discusses secured indexing of lung CT image (SILI which is a secured way of indexing the lung CT images with the patient information. Authentication is provided using the sender’s logo information and the secret key is used for embedding the watermark into the host image. Watermark is embedded into the region of Noninterest (RONI of the lung CT image. RONI is identified by segmenting the lung tissue from the CT scan image. The experimental results show that the proposed approach is robust against unauthorized access, noise, blurring, and intensity based attacks.

  11. Neurological ct Scan Value for Ictus in Cienfuegos Province

    Directory of Open Access Journals (Sweden)

    Idaylí Pérez Rodríguez

    2007-05-01

    Full Text Available Backgrounds: CT scan constitutes a very important technique in the diagnosis of the cerebrovascular disease. The impact this transcendental event had and will continue having in the medicine area is impossible to state in terms of dimensions during the next years. Objective: To determine the neurological CT scan value for ictus in our milieu. Methods: A retrospective, prospective, longitudinal study of a series of cases performed during a review of statistical reports as well as that of Stroke data base which stores information of patients with neurocitus in our province, and which is based on others aspects founds by means of neurological CT scan. Results: CT scan allowed us to diagnose the type of cerebrovascular event (75.55 % ischemic events, 24.45% hemorrhagic events. It also contributed to the necessary data such as the localization (with predominium of 35.55% in more than one area, and 7.40 % in the parietal area. The presence of cerebral edema was verified in 16.29% of the cases as well as displacement of the midline in 7.40 % both associated to a torpid evolution. It incorporated the Fisher and Le Roux scales showing their prognosis value with elevated measures for deceased patients and decreased values for survivors without disability. Conclusions: The diagnosis and prognosis value were proved as well as CT scan behavior in our milieu. These aspects permit the reliable introduction of new therapeutic modalities in our province.

  12. Classication Methods for CT-Scanned Carcass Midsections

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    Computed tomography (CT) has successfully been applied in medical environments for decades. In recent years CT has also made its entry to the industrial environments, including the slaughterhouses. In this paper we investigate classication methods for an online CT system, in order to assist...... in the segmentation of the outer fat layer in the mid- section of CT-scanned pig carcasses. Prior information about the carcass composition can potentially be applied for a fully automated solution, in order to optimize the slaughter line. The methods comprise Markov Random Field and contextual Bayesian classication......, and are adapted to use neighbourhood information in 2D and 3D. Articial Poisson noise is added to the provided dataset to determine how well each of the methods handles noise. Good noise handling will allow lower dose scannings. The investigated methods did not perform better than the reference model in terms...

  13. Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT Imaging

    OpenAIRE

    Ypsilantis, Petros-Pavlos; Montana, Giovanni

    2016-01-01

    Computed tomography (CT) generates a stack of cross-sectional images covering a region of the body. The visual assessment of these images for the identification of potential abnormalities is a challenging and time consuming task due to the large amount of information that needs to be processed. In this article we propose a deep artificial neural network architecture, ReCTnet, for the fully-automated detection of pulmonary nodules in CT scans. The architecture learns to distinguish nodules and...

  14. Noncontrast perfusion single-photon emission CT/CT scanning: a new test for the expedited, high-accuracy diagnosis of acute pulmonary embolism.

    Science.gov (United States)

    Lu, Yang; Lorenzoni, Alice; Fox, Josef J; Rademaker, Jürgen; Vander Els, Nicholas; Grewal, Ravinder K; Strauss, H William; Schöder, Heiko

    2014-05-01

    Standard ventilation and perfusion (V˙/Q˙) scintigraphy uses planar images for the diagnosis of pulmonary embolism (PE). To evaluate whether tomographic imaging improves the diagnostic accuracy of the procedure, we compared noncontrast perfusion single-photon emission CT (Q˙-SPECT)/CT scans with planar V˙/Q˙scans in patients at high risk for PE. Between 2006 and 2010, most patients referred for diagnosis of PE underwent both Q˙-SPECT/CT scan and planar V˙/Q˙scintigraphy. All scans were reviewed retrospectively by four observers; planar scans were read with modified Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) II and Prospective Investigative Study of Pulmonary Embolism Diagnosis (PISA-PED) criteria. On Q˙-SPECT/CT scan, any wedge-shaped peripheral perfusion defect occupying > 50% of a segment without corresponding pulmonary parenchymal or pleural disease was considered to show PE. The final diagnosis was established with a composite reference standard that included ECG, ultrasound of lower-extremity veins, D-dimer levels, CT pulmonary angiography (when available), and clinical follow-up for at least 3 months. One hundred six patients with cancer and mean Wells score of 4.4 had sufficient follow-up; 22 patients were given a final diagnosis of PE, and 84 patients were given a final diagnosis of no PE. According to PIOPED II, 13 studies were graded as intermediate probability. Sensitivity and specificity for PE were 50% and 98%, respectively, based on PIOPED II criteria; 86% and 93%, respectively, based on PISA-PED criteria; and 91% and 94%, respectively, based on Q˙-SPECT/CT scan. Seventy-six patients had additional relevant findings on the CT image of the Q˙-SPECT/CT scan. Noncontrast Q˙-SPECT/CT imaging has a higher accuracy than planar V˙/Q˙imaging based on PIOPED II criteria in patients with cancer and a high risk for PE.

  15. Computed Tomography (CT) Scans and Cancer

    Science.gov (United States)

    ... and other imaging procedures be included in the electronic medical records of patients treated at the center ( ... posts that are written by individuals from outside the government may be owned by the writer, and graphics ...

  16. Incidental Findings on CT Scans in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Ryan J. Thompson

    2011-01-01

    Full Text Available Objectives. Incidental findings on computed tomography (CT scans are common. We sought to examine rates of findings and disclosure among discharged patients who received a CT scan in the ED. Methods. Retrospective chart review (Aug-Oct 2009 of 600 patients age 18 and older discharged home from an urban Level 1 trauma center. CT reports were used to identify incidental findings and discharge paperwork was used to determine whether the patient was informed of these findings. Results. There were 682 CT scans among 600 patients: 199 Abdomen & Pelvis, 405 Head, and 78 Thorax. A total of 348 incidental findings were documented in 228/682 (33.4% of the scans, of which 34 (9.8% were reported to patients in discharge paperwork. Patients with 1 incidental finding were less likely to receive disclosure than patients with 2 or more (=.010. Patients age <60 were less likely to have incidental findings (<.001. There was no significant disclosure or incidental finding difference by gender. Conclusions. While previous research suggests that CT incidental findings are often benign, reporting to patients is recommended but this is rarely happening.

  17. Single energy micro CT SkyScan 1173 for the characterization of urinary stone

    Science.gov (United States)

    Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.

    2016-08-01

    A urinary stone is a solid piece of material produced from crystallization of excreted substances in the urine. Knowledge of the composition of urinary stones is essential to determine the suitable treatment for the patient. The aim of this research was to characterize urinary stones using single energy micro CT SkyScan 1173. Six human urinary stones were scanned in vitro using 80 kV in micro CT SkyScan 1173. The produced projection, images, were reconstructed using NRecon (in-house software from SkyScan). The images of urinary stones were analyzed using CT Analyser (CT An) to obtain information of the internal structure and the Hounsfield Unit (HU) value to determine the information regarding the composition of the urinary stones, respectively. The average HU values from certain region of interests in the same slice were compared with spectral curves of known materials from National Institute of Standards and Technology (NIST). From the analysis, the composition of the six scanned stones were obtained. Two stones are composed of cystine, two are composed of struvite, two other stones are composed of struvite+cystine. In conclusion, the single energy micro CT with 80 kV can be used identifying cystine and struvite urinary stone.

  18. Spinal CT scan, 2. Lumbar and sacral spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ., Aichi (Japan))

    1982-08-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival.

  19. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded...... as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones....

  20. Analysis of cranial CT-scan findings in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, F.; Andoh, T.; Une, K.; Takamatsu, T. (Kitakyushu Municipal Sogo-Ryoiku Center (Japan))

    1981-06-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed.

  1. The Impact of Sources of Variability on Parametric Response Mapping of Lung CT Scans.

    Science.gov (United States)

    Boes, Jennifer L; Bule, Maria; Hoff, Benjamin A; Chamberlain, Ryan; Lynch, David A; Stojanovska, Jadranka; Martinez, Fernando J; Han, Meilan K; Kazerooni, Ella A; Ross, Brian D; Galbán, Craig J

    2015-09-01

    Parametric response mapping (PRM) of inspiration and expiration computed tomography (CT) images improves the radiological phenotyping of chronic obstructive pulmonary disease (COPD). PRM classifies individual voxels of lung parenchyma as normal, emphysematous, or nonemphysematous air trapping. In this study, bias and noise characteristics of the PRM methodology to CT and clinical procedures were evaluated to determine best practices for this quantitative technique. Twenty patients of varying COPD status with paired volumetric inspiration and expiration CT scans of the lungs were identified from the baseline COPD-Gene cohort. The impact of CT scanner manufacturer and reconstruction kernels were evaluated as potential sources of variability in PRM measurements along with simulations to quantify the impact of inspiration/expiration lung volume levels, misregistration, and image spacing on PRM measurements. Negligible variation in PRM metrics was observed when CT scanner type and reconstruction were consistent and inspiration/expiration lung volume levels were near target volumes. CT scanner Hounsfield unit drift occurred but remained difficult to ameliorate. Increasing levels of image misregistration and CT slice spacing were found to have a minor effect on PRM measurements. PRM-derived values were found to be most sensitive to lung volume levels and mismatched reconstruction kernels. As with other quantitative imaging techniques, reliable PRM measurements are attainable when consistent clinical and CT protocols are implemented.

  2. Depiction of Nidi and Fibrovascular Zones of Osteoid Ostemas Using Gamma Correction Tc 99m HDP Pinhole Bone Scan and Conventional Radiograph, and Correlation with CT, MRI, and PVC Phantom Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Youg Whee [Sung Ae Hospital, Seoul (Korea, Republic of); Kim, Sung Hoon; Chung, Yong An; Bahk, Won Jong; Park, Jung Mee; Kang, You Mee; Choi, Woo Hee; Park, Young Ha; Sohn, Hyung Sun; Kim, Byung Ki; Chung, Soo Kyo [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2011-03-15

    For the precise imaging diagnosis of osteoid osteoma (OO), the identification of the nidus and fibrovascular zone (FVZ) is essential. However, the latter sign has received little attention because it is difficult to demonstrate. We applied the recently introduced gamma correction (GC) to depict the FVZ on pinhole bone scan (PBS), conventional radiography (CR), and computed tomography (CT). Non gamma correction MRI was also analyzed for reference. Ten patients with histologically proven diagnoses of OO were enrolled in this retrospective study. PBS, CR, and CT were processed by GC to demonstrate the nidi and FVZ as distinct yet integrating components of OO. PBS was performed using a 4mm pinhole collimator 3 h after iv injection of 925 to 1, 110 MBq (25 to 30mCi) of Tc 99m HDP, and anteroposterior and mediolateral CR and transverse CT were taken according to the standard technique. MRI sequences included T1 and T2 weighted images. For gamma correction, we utilized the Photo Correction Wizard program of ACD Photo Editor v3. 1. A team of three qualified nuclear physician radiologists, two nuclear physicians, and one MRI specialist read bone scans, radiographs, and MRIs of OO according to each specialty, and orthopaedic aspects and histology were reviewed by one qualified orthopedic surgeon and two qualified pathologists, respectively. Each observer first read the images separately with basic information about the aim of the study given and then in concert. Interpretive disagreement was settled by discussion and consensus. On pinhole scan, nidi were presented as areas of intense tracer uptake in all cases, and, importantly after GC, a thin ring like zone with lower tracer uptake became visible in seven out of ten cases. GCCR also revealed a thin lucent zone that circumscribed the nidi in six out of ten cases and GCCT in two of four cases. MRI, without GC, presented nidi with high signal in the center and a thin ring like zone with low signal in the periphery in five out

  3. CT Diagnosis of Fitz-Hugh and Curtis Syndrome: Value of the Arterial Phase Scan

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Seung Ho; Kim, Myeong Jin; Lim, Joon Seok; Kim, Joo Hee; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-02-15

    We wanted to evaluate the role of the arterial phase (AP) together with the portal venous phase (PP) scans in the diagnosis of Fitz-Hugh-Curtis syndrome (FHCS) with using computed tomography (CT). Twenty-five patients with FHCS and 25 women presenting with non-specifically diagnosed acute abdominal pain and who underwent biphasic CT examinations were evaluated. The AP scan included the upper abdomen, and the PP scan included the whole abdomen. Two radiologists blindly and retrospectively reviewed the PP scans first and then they reviewed the AP plus PP scans. The diagnostic accuracy of FHCS on each image set was compared for each reader by analyzing the area under the receiver operating characteristic curve (Az). Weighted kappa (wk) statistics were used to measure the interobserver agreement for the presence of CT signs of the pelvic inflammatory disease (PID) on the PP images and FHCS as the diagnosis based on the increased perihepatic enhancement on both sets of images. The individual diagnostic accuracy of FHCS was higher on the biphasic images (Az = 0.905 and 0.942 for reader 1 and 2, respectively) than on the PP images alone (Az = 0.806 and 0.706, respectively). The interobserver agreement for the presence of PID on the PP images was moderate (wk = 0.530). The interobserver agreement for FHCS as the diagnosis was moderate on only the PP images (wk = 0.413), but it was substantial on the biphasic images (wk 0.719). Inclusion of the AP scan is helpful to depict the increased perihepatic enhancement, and it improves the diagnostic accuracy of FHCS on CT.

  4. CT Imaging: Basics and New Trends

    Science.gov (United States)

    Peyrin, Françoise; Engelke, Klaus

    This chapter presents the principle of X-ray CT and its evolution during the last 40 years. The first section describes the physical basis of X-ray CT, tomographic image reconstruction algorithms, and the source of artifacts in X-ray CT images. The second section is devoted to the evolution of CT technology from the first translation-rotation systems to multi-slice spiral CTs currently used today. The next section addresses specific developments of CT technology and applications, like perfusion CT, quantitative CT, and spectral CT. The fourth section introduces the problem of radiation exposure delivered to the patient and its evaluation. Finally the last section addresses the development in micro- and even nano-CT which is a rapidly evolving area in preclinical imaging and biology.

  5. Quantitative image quality evaluation for cardiac CT reconstructions

    Science.gov (United States)

    Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.; Balhorn, William; Okerlund, Darin R.

    2016-03-01

    Maintaining image quality in the presence of motion is always desirable and challenging in clinical Cardiac CT imaging. Different image-reconstruction algorithms are available on current commercial CT systems that attempt to achieve this goal. It is widely accepted that image-quality assessment should be task-based and involve specific tasks, observers, and associated figures of merits. In this work, we developed an observer model that performed the task of estimating the percentage of plaque in a vessel from CT images. We compared task performance of Cardiac CT image data reconstructed using a conventional FBP reconstruction algorithm and the SnapShot Freeze (SSF) algorithm, each at default and optimal reconstruction cardiac phases. The purpose of this work is to design an approach for quantitative image-quality evaluation of temporal resolution for Cardiac CT systems. To simulate heart motion, a moving coronary type phantom synchronized with an ECG signal was used. Three different percentage plaques embedded in a 3 mm vessel phantom were imaged multiple times under motion free, 60 bpm, and 80 bpm heart rates. Static (motion free) images of this phantom were taken as reference images for image template generation. Independent ROIs from the 60 bpm and 80 bpm images were generated by vessel tracking. The observer performed estimation tasks using these ROIs. Ensemble mean square error (EMSE) was used as the figure of merit. Results suggest that the quality of SSF images is superior to the quality of FBP images in higher heart-rate scans.

  6. CT-scan bij stomp buiktrauma bij kinderen : veel stralen en weinig opbrengst?

    NARCIS (Netherlands)

    Nellensteijn, David R; El Moumni, Mostafa; Greuter, Marcel J W; Kneyber, Martin C J; Hulscher, Jan B F

    2013-01-01

    Blunt abdominal trauma in children occurs fairly frequently. Although computed tomography scanning is considered by many to be the gold standard, in children who are hemodynamically stable, CT images do not usually result in new perspectives that lead to changes in treatment management. However, the

  7. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  8. Calibration free beam hardening correction for cardiac CT perfusion imaging

    Science.gov (United States)

    Levi, Jacob; Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    Myocardial perfusion imaging using CT (MPI-CT) and coronary CTA have the potential to make CT an ideal noninvasive gate-keeper for invasive coronary angiography. However, beam hardening artifacts (BHA) prevent accurate blood flow calculation in MPI-CT. BH Correction (BHC) methods require either energy-sensitive CT, not widely available, or typically a calibration-based method. We developed a calibration-free, automatic BHC (ABHC) method suitable for MPI-CT. The algorithm works with any BHC method and iteratively determines model parameters using proposed BHA-specific cost function. In this work, we use the polynomial BHC extended to three materials. The image is segmented into soft tissue, bone, and iodine images, based on mean HU and temporal enhancement. Forward projections of bone and iodine images are obtained, and in each iteration polynomial correction is applied. Corrections are then back projected and combined to obtain the current iteration's BHC image. This process is iterated until cost is minimized. We evaluate the algorithm on simulated and physical phantom images and on preclinical MPI-CT data. The scans were obtained on a prototype spectral detector CT (SDCT) scanner (Philips Healthcare). Mono-energetic reconstructed images were used as the reference. In the simulated phantom, BH streak artifacts were reduced from 12+/-2HU to 1+/-1HU and cupping was reduced by 81%. Similarly, in physical phantom, BH streak artifacts were reduced from 48+/-6HU to 1+/-5HU and cupping was reduced by 86%. In preclinical MPI-CT images, BHA was reduced from 28+/-6 HU to less than 4+/-4HU at peak enhancement. Results suggest that the algorithm can be used to reduce BHA in conventional CT and improve MPI-CT accuracy.

  9. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  10. Diagnostic Utility of CT Scan for Acute Headache

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2009-08-01

    Full Text Available ED records for 364 children 2 to 5 years of age who presented to the Children’s National Medical Center ED, Washington, DC, between July 1, 2003, and June 30, 2006, with headache as their chief complaint, were examined to determine whether CT scans led to better acute management, justifying the risk of radiation.

  11. Impact of low-dose CT scan in dual timepoint investigations: a phantom study

    DEFF Research Database (Denmark)

    Micheelsen, M A; Jensen, Mikael

    2011-01-01

    with a CT image and also use the CT for attenuation correction. In any practical hospital setting, 1 hour is too long to occupy the scanner bed and a second CT procedure thus becomes necessary. This study tries to validate to what extent the dose/quality of the second CT scan can be lowered, without...... compromising attenuation correction, lesion detection and quantification. Using a standard NEMA phantom with the GE Discovery PET/CT scanner, taken in and out between scan sessions, we have tried to find the minimal CT dose necessary for the second scan while still reaching tissue activity quantification...... within predetermined error limits. For a hot sphere to background activity concentration ratio of 1:5, the average uptake (normalised by the time corrected input activity concentration) in a sphere of 6 cm3 was found to be 0.90 ± 0.08 for the standard scan, yielding a dose of 5.5 mGy, and 0.90 ± 0...

  12. Scanning strategies for imaging arrays

    CERN Document Server

    Kovács, A

    2008-01-01

    Large-format (sub)millimeter wavelength imaging arrays are best operated in scanning observing modes rather than traditional position-switched (chopped) modes. The choice of observing mode is critical for isolating source signals from various types of noise interference, especially for ground-based instrumentation operating under a bright atmosphere. Ideal observing strategies can combat 1/f noise, resist instrumental defects, sensitively recover emission on large scales, and provide an even field coverage -- all under feasible requirements of telescope movement. This work aims to guide the design of observing patterns that maximize scientific returns. It also compares some of the popular choices of observing modes for (sub)millimeter imaging, such as random, Lissajous, billiard, spiral, On-The-Fly (OTF), DREAM, chopped and stare patterns. Many of the conclusions are also applicable other imaging applications and imaging in one dimension (e.g. spectroscopic observations).

  13. Clinical utility of 18 Fluorodeoxyglucose (FDG-PET/CT scans in patients with suspect ocular tuberculosis

    Directory of Open Access Journals (Sweden)

    Salil Mehta

    2013-01-01

    Full Text Available Systemic imaging of patients with suspect ocular tuberculosis include chest X-rays and computed tomography (CT scans. Reports have suggested a role for 18 fluorodeoxyglucose-positron emission tomography/CT (FDG-PET/CT scans. We report on the clinical utility of 18 FDG PET/CT in two patients. Case 1: A 38-year-old female patient presented with recurrent anterior uveitis. A 18 FDG-PET scan revealed metabolically active supraclavicular and chest lymph nodes. An aspiration cytology of the cervical lymph node revealed caseating granulomas suggestive of tuberculosis. Case 2: A 58-year-old female patient presented with recurrent anterior uveitis. A 18 FDG-PET scan revealed metabolically active lymph nodes in the neck. A biopsy of the cervical lymph node revealed epithelioid granulomas suggestive of tuberculosis. Both patients were started on standard antitubercular therapy with a subsequent marked reduction of activity. PET/CT scans may suggest the sites of safe high-yield biopsies.

  14. Alternative oblique head CT scanning technique reduces bone artifact and improves interpretability of brainstem anatomy

    Directory of Open Access Journals (Sweden)

    Sam Douglas Kampondeni

    2010-06-01

    Full Text Available Brainstem pathology due to infections, infarcts and tumors are common in developing countries, but neuroimaging technology in these resource-poor settings is often limited to single slice, and occasionally spiral, CT. Unlike multislice CT and MRI, single slice and spiral CT are compromised by bone artifacts in the posterior fossa due to the dense petrous bones, often making imaging of the brainstem non-diagnostic. With appropriate head positioning, the petrous ridges can be avoided with 40˚ sagittal oblique scans parallel to either petrous ridge. We describe an alternative sagittal oblique scanning technique that significantly reduces brainstem CT artifacts thereby improving clarity of anatomy. With Inst­itutional Ethical approval, 13 adult patients were enrolled (5 males; 39%. All patients had routine axial brain CT and sagittal oblique scans with no lesions found. Images were read by 2 readers who gave a score for amount of artefact and clarity of structures in the posterior fossa. The mean artifact score was higher for routine axial images compared to sagittal oblique (2.92 vs. 1.23; P<0.0001. The mean anatomical certainty scores for the brainstem were significantly better in the sagittal oblique views compared to routine axial (1.23 vs. 2.77; P<0.0001. No difference was found between the two techniques with respect to the fourth ventricle or the cerebellum (axial vs. sag oblique: 1.15 vs. 1.27; P=0.37. When using single slice CT, the sagittal oblique scanning technique is valuable in improving clarity of anatomy in the brainstem if axial images are non-diagnostic due to bone artifacts.

  15. Automatic segmentation of bladder in CT images

    Institute of Scientific and Technical Information of China (English)

    Feng SHI; Jie YANG; Yue-min ZHU

    2009-01-01

    Segmentation of the bladder in computerized tomography (CT) images is an important step in radiation therapy planning of prostate cancer. We present a new segmentation scheme to automatically delineate the bladder contour in CT images with three major steps. First, we use the mean shift algorithm to obtain a clustered image containing the rough contour of the bladder, which is then extracted in the second step by applying a region-growing algorithm with the initial seed point selected from a line-by-line scanning process. The third step is to refine the bladder contour more accurately using the rolling-ball algorithm. These steps are then extended to segment the bladder volume in a slice-by-slice manner. The obtained results were compared to manual segmentation by radiation oncologists. The average values of sensitivity, specificity, positive predictive value, negative predictive value, and Hausdorff distance are 86.5%, 96.3%, 90.5%, 96.5%, and 2.8 pixels, respectively. The results show that the bladder can be accurately segmented.

  16. Brain CT scanning of children with purulent meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Mishima, M.; Suzuki, M.; Nagata, M.; Kawamura, G.

    1986-12-01

    Nine of 21 children with purulent meningitis showed abnormal findings in brain CT when admitted. All of the abnormal group were less than 12 months of age, but 75 % of the normal group were more than 1 year old. The period of positive CRP was longer and the level of sugar in CSF was lower in abnormal group when compared with normal group. Because convulsion and EEG abnormalities were observed similarly in both groups, it may be difficult to determine the organic changes of the brain clinically. Brain CT scanning is recommended as soon as possible after the onset of purulent meningitis.

  17. Computer-assisted solid lung nodule 3D volumetry on CT : influence of scan mode and iterative reconstruction: a CT phantom study

    NARCIS (Netherlands)

    Coenen, Adriaan; Honda, Osamu; van der Jagt, Eric J.; Tomiyama, Noriyuki

    2013-01-01

    To evaluate the effect of high-resolution scan mode and iterative reconstruction on lung nodule 3D volumetry. Solid nodules with various sizes (5, 8, 10 and 12 mm) were placed inside a chest phantom. CT images were obtained with various tube currents, scan modes (conventional mode, high-resolution m

  18. Hepatic CT image query using Gabor features

    Institute of Scientific and Technical Information of China (English)

    Chenguang Zhao(赵晨光); Hongyan Cheng(程红岩); Tiange Zhuang(庄天戈)

    2004-01-01

    A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented.For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transform is utilized to analyze the texture of the pathology bearing region and extract the corresponding feature vectors. For a given sample image, we compare its feature vector with those of other images. Similar images with the highest rank are retrieved. In experiments, 45 liver CT images are collected, and the effectiveness of Gabor texture for content based retrieval is verified.

  19. Detection of Dental Pathologies in Routine Paranasal CT Scans: A Retrospective Study.

    Science.gov (United States)

    Bulbul, Erdogan; Yanik, Bahar; Demirpolat, Gulen

    2017-07-01

    Multidetector Computed Tomography (MDCT) is a widespread method for evaluating paranasal sinuses and nasal cavity in daily practice. The maxillary teeth are in field of view in a paranasal sinus CT scan and it is possible to detect dental pathologies with CT. To determine the incidence of maxillary teeth pathologies in routine paranasal sinus CT scans. A retrospective study was conducted. Consecutive 395 paranasal sinus CT scans were evaluated. All CT images were obtained with a 64 detector-CT. Patients with previous facial trauma, operation, invasive tumors and repeated exams were excluded. Detected findings were classified as "tooth loss, dental restorations or procedures and dental pathologies (carious lesions, dental developmental anomalies, periapical lesions and periodontal diseases). The proportion of findings was reported as simple percentiles. Three hundred and eighty-four CT scans were included in the study. Dental restorations or procedures were determined in 129 (33.5%) patients. A total of 34 (8.8%) patients had normal teeth count and morphology. A total of 264 (64.3%) patients had at least one tooth loss. A total of 195 (51%) patients had at least one or more dental pathology. Number of dental carious lesions, dental developmental anomalies, periapical lesions and periodontal disease were 104 (27.0%), 78 (14.3%), 46 (11.9%), 44 (11.4%), respectively. Dental pathologies were encountered in more than half of the patients. Detecting dental pathologies may prevent tooth loss and improve oral health. The radiologist should keep in mind dental pathologies while evaluating paranasal sinus CT in daily practice.

  20. Size variation and collapse of emphysema holes at inspiration and expiration CT scan: evaluation with modified length scale method and image co-registration.

    Science.gov (United States)

    Oh, Sang Young; Lee, Minho; Seo, Joon Beom; Kim, Namkug; Lee, Sang Min; Lee, Jae Seung; Oh, Yeon Mok

    2017-01-01

    A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT). Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method (r-values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942). The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT) parameters using the Pearson's correlation test. The mean extents of low-attenuation area (LAA), E1 (size variation and collapse of emphysema holes may be useful for understanding the dynamic collapse of emphysema and its functional relation.

  1. Interactive lung segmentation in abnormal human and animal chest CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Kockelkorn, Thessa T. J. P., E-mail: thessa@isi.uu.nl; Viergever, Max A. [Image Sciences Institute, University Medical Center Utrecht, 3584 CX Utrecht (Netherlands); Schaefer-Prokop, Cornelia M. [Department of Radiology, Meander Medical Centre, 3813 TZ Amersfoort, The Netherlands and Diagnostic Image Analysis Group, Radboud University Nijmegen Medical Centre, 6525 GA Nijmegen (Netherlands); Bozovic, Gracijela [Center for Diagnostic Imaging and Physiology, Skåne University Hospital, Lund University, SE-221 85 Lund (Sweden); Muñoz-Barrutia, Arrate [Cancer Imaging Laboratory, Center for Applied Medical Research, University of Navarra, ES-31008 Pamplona, Navarra (Spain); Rikxoort, Eva M. van [Diagnostic Image Analysis Group, Radboud University Nijmegen Medical Centre, 6525 GA Nijmegen (Netherlands); Brown, Matthew S. [Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, David Geffen School of Medicine at UCLA, University of California, Los Angeles, California 90024 (United States); Jong, Pim A. de [Department of Radiology, University Medical Center Utrecht, 3584 CX Utrecht (Netherlands); Ginneken, Bram van [Diagnostic Image Analysis Group, Radboud University Nijmegen Medical Centre, 6525 GA Nijmegen (Netherlands); Image Sciences Institute, University Medical Center Utrecht, 3584 CX Utrecht (Netherlands)

    2014-08-15

    Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in

  2. A novel sedimentological method based on CT-scanning: Use for tomographic characterization of the Galicia Interior Basin

    Science.gov (United States)

    Mena, Anxo; Francés, Guillermo; Pérez-Arlucea, Marta; Aguiar, Pablo; Barreiro-Vázquez, José Daniel; Iglesias, Alfredo; Barreiro-Lois, Andrés

    2015-05-01

    Non-destructive techniques of core analysis, especially of marine cores, are being broadly employed for sedimentary, paleoceanographic and paleoclimate research. In particular, Computed Tomography scanning (CT-scanning) allows acquisition of 3D and 2D images, according to desired planes, and thus the identification of sedimentary structures, large grains and their distributions as well as direct measurements of material densities. The most significant contribution of this technique is the possibility of getting results before opening the core. In this work CT-scan data obtained for five cores from the Galicia Interior Basin (GIB, NW Peninsula Iberia) are presented and discussed, focussing on (1) methodology of the CT-scan use, (2) tomographic description of sedimentary facies identified in the GIB, (3) treatment of the numeric data obtained with CT-scanning using specific software (anidoC), and (4) comparison of tomographic data with data obtained by conventional methodologies of core analysis. The most singular feature of GIB cores is the presence of Ice Rafted Debris (IRD) deposited during late Pleistocene Heinrich Events (HE), which can be easily recognized using the CT-scan by the presence of high radio-density grains immersed in a low radio-density matrix. Comparison of CT-scan data with analytical sedimentary data and HE proxies performed on the cores validates the CT-scanning method as a powerful tool to improve correlations, identify well-constrained events, and make more accurate basin reconstructions without opening all the cores in an oceanographic study.

  3. CT scan findings of patients with Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hisaharu; Takanashi, Aiko; Hirayama, Yoshito; Sakuragawa, Norio; Arima, Masataka; Tateno, Akihiko; Koide, Hiroyoshi.

    1989-05-01

    CT findings and clinical features were analyzed in 16 female patients with Rett syndrome, whose ages were between 4 and 20. Fifteen patients had microcrania. Twelve patients were able to stand and run; however, the remaining 4 patients had the only ability to sit. CT revealed an atrophy of the ponse and various degrees of dilatation in the Silvian fissure, frontal sulcus, and space between the cranium and the frontal polar lobe. An atrophy in the frontal lobe, cerebral cortex surrounding the Silvian fissure, and white matter directly below the cortex seemed to have an important role in the occurrence of this syndrome. There was, however, no definitive correlation between the degree of atrophy and both the patient's age and motor function. Serial CT scannings with clinical process are required. (Namekawa, K).

  4. Progression of CT scan findings in Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hisaharu; Hirayama, Yoshito; Sakuragawa, Norio; Arima, Masataka (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan))

    1989-07-01

    Progression of the lesions revealed by CT scan was observed in five girls with Rett syndrome. The most distinct and common finding was progressive dilatation of Sylvian fissures, frontal extracerebral space, interhemispheric fissure, and sulci mainly in frontal lobe. It may indicate progressive lesion in the frontal and the temporal lobes. In addition, dilatation of the anterior horns of the lateral ventricles and the third ventricle was noted in some cases. Brainstem and cerebellum were small at any age with some morphological development as the patients became elder. Neither malformations nor abnormalities in density were found in any case. It is concluded that the main lesion of Rett syndrome on CT scan is progressive and localized in the frontal and the temporal lobes. (author).

  5. PET/CT imaging in head and neck tumors; PET-CT-Bildgebung bei Kopf-Hals-Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J. [Universitaetsklinikum Bonn, Klinik und Poliklinik fuer Nuklearmedizin (Germany); Straehler-Pohl, H.J. [Universitaetsklinikum Bonn, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde (Germany); Jaeger, U. [Universitaetsklinikum Bonn, Radiologische Klinik (Germany)

    2004-11-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [German] Die Bestimmung der Wertigkeit der kombinierten PET-CT-Untersuchung zum Nachweis maligner Kopf-Hals-Tumoren und ihrer Metastasen. Bei 51 Patienten wurden Ganzkoerperuntersuchungen mit dem kombiniertem PET-CT-System durchgefuehrt. Die CT erfolgte ohne i.v. Kontrastmittelgabe. Die Ergebnisse wurden in ihrer diagnostischen Aussage einerseits getrennt fuer native CT- und FDG-PET-Bildgebung und andererseits fuer das fusionierte Bild verglichen. Von 153 Laesionen wurden 97 im CT und 136 im FDG-PET als maligne, 33 im CT und 7 im FDG-PET als malignitaetsverdaechtig, 23 im CT und 10 in der FDG-PET als benigne beurteilt. Die Anzahl der konkordanten Ergebnisse betrug 94 (61%), die der diskordanten 59 (39 %). Mit der PET-CT konnten alle Primaertumoren und Rezidive entdeckt werden, die Nachweisrate eines unbekannten Primaertumors betrug 45%. Im Vergleich zur alleinigen PET- oder CT-Untersuchung erhoehen sich bei der kombinierten PET-CT Sensitivitaet, Spezifitaet sowie die

  6. Nasal polyps with metaplastic ossification: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yi Kyung; Kim, Hyung-Jin; Kim, Eunhee; Kim, Sung Tae [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jinna [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Chung, Seung-Kyu [Sungkyunkwan University School of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Seoul (Korea, Republic of); Ko, Young-Hyeh [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2010-12-15

    Metaplastic ossification is a rare event in nasal polyps. The purpose of this study was to review the computed tomography (CT) and magnetic resonance (MR) imaging findings of nasal polyps with metaplastic ossification. CT (n = 5) and MR (n = 3) images of five patients (four men and one woman; mean age, 59 years) with surgically proven nasal polyp with metaplastic ossification were retrospectively reviewed. The location and morphologic characteristics of metaplastic ossification were documented as well. All lesions were seen as lobulated (n = 3), ovoid (n = 1), or dumbbell-shaped (n = 1) benign-looking masses with a mean size of 3.7 cm (range, 2.4-6.5 cm), located unilaterally in the posterior nasal cavity and nasopharynx (n = 2), posterior nasoethmoidal tract (n = 2), and maxillary sinus and nasal cavity (n = 1). Compared with the brain stem, the soft tissue components of all lesions demonstrated isoattenuation on precontrast CT scans, slight hypointensity on T1-weighted MR images, and hyperintensity on T2-weighted MR images. On contrast-enhanced MR images, heterogeneous enhancement with marked peripheral enhancement was seen in two and homogeneous moderate enhancement in one. All lesions contained centrally located radiodense materials on CT scans, the shape of which was multiple clustered in three, single nodular in one, and single large lobulated in one. Although rare, metaplastic ossification can occur within nasal polyps. The possibility of its diagnosis may be raised when one sees a benign-looking sinonasal mass with centrally located radiodense materials on CT scans. MR imaging may be useful when mycetoma or inverted papilloma cannot be ruled out on CT scans. (orig.)

  7. Role of high resolution multislice CT scan in otosclerosis

    Directory of Open Access Journals (Sweden)

    Atef EL Maraghy

    2015-11-01

    Full Text Available This prospective study was carried out to assess the radiological findings in patients with otosclerosis using high resolution multislice CT scan and to correlate these findings with audiological findings in those patients. This study was done at Al Azhar University hospitals during the period from Jan 2012 to Jun 2014. Thirty-two patients were enrolled in this study; 13 (40.63% males and 19 (59.37% females. Their age ranged from 13 to 55 with a mean of 36.21 ± 8.7 years. Written consent was taken from all patients. Multislice CT scan was done to all patients and reports were done by computer assisted analysis with thorough audiological assessment including pure tone audiometry, tympanometry and stapedial reflex. Positive findings were present in 40/58 ears (69% while negative findings were present in 18/58 ears (31%. Otosclerotic foci were more detected when slice thickness was lesser than one millimeter especially at fissula ante fenestrum and round window region. There was a good correlation between air bone gap and CT score (p = 0.002. High resolution multislice CT helps in the diagnosis of otosclerosis with sensitivity (69% and it aids in the diagnosis of doubtful cases. Otosclerosis has a special predilection to affect certain sites mainly the fissula ante fenestrum followed by the round window and the cochlear promontory.

  8. Analysis of functional CT scan in cervical vertebral disease

    Energy Technology Data Exchange (ETDEWEB)

    Hirofuji, Eiichi; Tanaka, Seisuke; Tomihara, Mitsuo; Kita, Hiroshi; Yamasaki, Hiroyuki

    1982-12-01

    The atlantoaxial joint showed displacement in various directions in rheumatoid arthritis and cervical spondylosis. The displacements were promoted by anterior flexion and rotatory movements, exerting great influences on the spnial cord. The intervertebral space between the 5th and 6th vertebra showed narrowing of the vertebral canal in cervical spondylosis and was promoted by posterior flexion to affect the spinal cord to a great extent. Functional CT scan was useful for observation of pathologic conditions of vertebral diseases.

  9. Prior CT imaging history for patients who undergo PAN CT for acute traumatic injury

    Directory of Open Access Journals (Sweden)

    Jeremy Kenter

    2015-06-01

    Full Text Available Objective. A single PAN scan may provide more radiation to a patient than is felt to be safe within a one-year period. Our objective was to determine how many patients admitted to the trauma service following a PAN scan had prior CT imaging within our six-hospital system.Methods. We performed a secondary analysis of a prospectively collected trauma registry. The study was based at a level-two trauma center and five affiliated hospitals, which comprise 70.6% of all Emergency Department visits within a twelve county region of southern Texas. Electronic medical records were reviewed dating from the point of trauma evaluation back to December 5, 2005 to determine evidence of prior CT imaging.Results. There were 867 patients were admitted to the trauma service between January 1, 2012 and December 31, 2012. 460 (53% received a PAN scan and were included in the study group. The mean age of the study group was 37.7 ± 1.54 years old, 24.8% were female, and the mean ISS score was 13.4 ± 1.07. The most common mechanism of injury was motor vehicle collision (47%. 65 (14%; 95% CI [11–18]% of the patients had at least one prior CT. The most common prior studies performed were: CT head (29%; 19–42%, CT Face (29%; 19–42% and CT Abdomen and Pelvis (18%; 11–30%.Conclusion. Within our trauma registry, 14% of patients had prior CT imaging within our hospital system before their traumatic event and PAN scan.

  10. A vast increase in the use of CT scans for investigating occult hip fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Robert, E-mail: Robert.jordan@doctors.org.uk; Dickenson, Edward, E-mail: edwarddickenson@doctors.org.uk; Westacott, Daniel, E-mail: dan_westacott@hotmail.com; Baraza, Njalalle, E-mail: njaleb@Doctors.Org.Uk; Srinivasan, Kuntrapka, E-mail: bijusri@Yahoo.Co.Uk

    2013-08-15

    Background: Early diagnosis in neck of femur fractures has been shown to improve outcome. The National Institute for Clinical Excellence recommends if an occult hip fracture is suspected then an MRI should be performed and if not available within 24 h a CT should be considered. At our centre, emergency MRI is rarely available and so CT is commonly used. Objectives: Our study aims to analyse the trends in CT use over a five year period for the diagnosis of neck of femur fractures. Methods: Both the number of patients with a hip fracture and those undergoing a CT hip to diagnose an occult injury were identified across two district general hospitals between 2006–2007 and 2010–2011. The time from initial radiograph to CT and initial radiograph to operation were calculated. Results: In 2006–2007, of 547 hip fractures, 20 CT hips were performed and 6 reported as a fractured neck of femur (30%). In 2010–2011, of 499 hip fractures, 239 CT hips were performed and 65 fractures were recognised (27%). The mean time from radiograph until CT scan was 2.0 days in 2007 and 3.2 days in 2011, which was a statistically significant difference (p < 0.001). For those diagnosed using a CT scan the mean time from admission X-ray to surgery was 1.2 days in 2007 and 3.6 days in 2011. Conclusion: Clinicians are becoming increasingly reliant on CT for the diagnosis of hip fractures with our data suggesting further imaging is one factor that can delay time to diagnosis and theatre.

  11. Image reconstruction for brain CT slices

    Institute of Scientific and Technical Information of China (English)

    吴建明; 施鹏飞

    2004-01-01

    Different modalities in biomedical images, like CT, MRI and PET scanners, provide detailed cross-sectional views of human anatomy. This paper introduces three-dimensional brain reconstruction based on CT slices. It contains filtering, fuzzy segmentation, matching method of contours, cell array structure and image animation. Experimental results have shown its validity. The innovation is matching method of contours and fuzzy segmentation algorithm of CT slices.

  12. Leigh syndrome. A comparison of CT scanning and pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Y.; Okamoto, K.; Somiya, K. (Hamamatsu Medical Center, Shizuoka (Japan)); Hokazono, Y.; Tozuka, S.

    1981-11-01

    A male infant developed hypotonia at 5 months, vomiting, diarrhea, fever, generalized clonic convulsion, tonic spasm and periodical opisthotonus at 8 months, swallowing difficulty at 10 months, pes equinovarus and optic atrophy at 11 months, and then tachypnea, and died at 14 months of age. Parents were consanguinous. Laboratory studies revealed elevated serum LDH, CPK, lactate and Pyruvate. TPP-ATP phosphoryl transferase inhibitor was negative in urine. EEG showed irregular and diffuse slow waves and periodic diffuse spike and waves. CT scan at 9 months of age showed slightly low attenuation areas in the putamen bilaterally. At 11 months, a diffuse cerebral atrophy was found, and the low attenuation of the basal ganglia became more definite. No enhanced lesion was seen at 13 months of age. Thiamine tetra-hydrofurfuryl disulfide and lipoic acid were tried without success. The pathological findings of the brain were astrogliosis and proliferation of capillaries in putamen, thalamus, caudate nucleus, substantia nigra, pontine brachium and cerebral cortex, which were symmetrically involved. The symmetrical cavitation was found in putamen. Optic nerve and mamillary body were spared. CT scan findings corresponded well with the pathology of the necrotic lesions of the brain. It was concluded that these CT scan pictures described above may be diagnostic of Leigh syndrome.

  13. Software windows for the display of CT-images

    Energy Technology Data Exchange (ETDEWEB)

    Gell, G.; Sager, W.D.; Toelly, E.

    1983-03-01

    Software windows are a flexible and general method for defining arbitrary functions for the mapping of Hounsfield-numbers of CT-scans on to the grey levels of the display image. The method which is illustrated with the aid of a few examples has been implemented on an EMI viewing console.

  14. Characterizing a discrete-to-discrete X-ray transform for iterative image reconstruction with limited angular-range scanning in CT

    DEFF Research Database (Denmark)

    Sidky, Emil; Jørgensen, Jakob Heide; Pan, Xiaochuan

    2012-01-01

    Iterative image reconstruction in computed tomography often employs a discrete-to-discrete (DD) linear data model, and many of the aspects of the image recovery relate directly to the properties of this linear model. While much is known about the properties of the continuous X-ray, the correspond......Iterative image reconstruction in computed tomography often employs a discrete-to-discrete (DD) linear data model, and many of the aspects of the image recovery relate directly to the properties of this linear model. While much is known about the properties of the continuous X...

  15. 3D Reconstruction in Spiral Multislice CT Scans

    Directory of Open Access Journals (Sweden)

    M. Ghafouri

    2005-08-01

    Full Text Available Introduction & Background: The rapid development of spiral (helical computed tomography (CT has resulted in exciting new applications for CT. One of these applications, three-dimensional (3D CT with volume ren-dering, is now a major area of clinical and academic interest. One of the greatest advantages of spiral CT with 3D volume rendering is that it provides all the necessary information in a single radiologic study (and there-fore at the lowest possible price in cases that previously required two or more studies. Three-dimensional vol-ume rendering generates clinically accurate and immediately available images from the full CT data set with-out extensive editing. It allows the radiologist and clinician to address specific questions concerning patient care by interactively exploring different aspects of the data set. Three-dimensional images integrate a series of axial CT sections into a form that is often easier to interpret than the sections themselves and can be made to appear similar to other more familiar images such as catheter angiograms. The data are organized into a 3D matrix of volume elements (voxels. The screen of the computer monitor is a 2D-surface composed of discrete picture elements (pixels. Presenting what is stored in memory (ie, floating within the monitor on a 2D-screen is a challenge, but it is the very problem that 3D reconstruc-tion software has creatively solved. Voxel selection is usually accomplished by projecting lines (rays through the data set that correspond to the pixel matrix of the desired 2D image. Differences in the images produced with various 3D rendering techniques are the result of variations in how voxels are selected and weighted. In this article, I compare 3D volume rendering of spiral CT data with other rendering techniques (shaded surface display, maximum intensity projection and present a brief history of 3D volume rendering and discuss the im-plementation of this promising technology in terms of

  16. Diagnosis of pituitary microadenomas by CT scan. Detection of the microadenoma by high resolution coronal scan

    Energy Technology Data Exchange (ETDEWEB)

    Sakoda, K.; Uozumi, T. (Hiroshima Univ. (Japan). School of Medicine)

    1981-10-01

    Following a detection of abnormality of pituitary hormone, it is very important to know whether the abnormality is due to pituitary microadenoma for deciding treatment methods. To diagnose pituitary microadenoma, polytomography of the sella turcica has been used. The recently developed high resolution coronal CT scan is prone to be more valuable in diagnosing microadenoma. New findings by this method were reported.

  17. Combining generative and discriminative models for semantic segmentation of CT scans via active learning.

    Science.gov (United States)

    Iglesias, Juan Eugenio; Konukoglu, Ender; Montillo, Albert; Tu, Zhuowen; Criminisi, Antonio

    2011-01-01

    This paper presents a new supervised learning framework for the efficient recognition and segmentation of anatomical structures in 3D computed tomography (CT), with as little training data as possible. Training supervised classifiers to recognize organs within CT scans requires a large number of manually delineated exemplar 3D images, which are very expensive to obtain. In this study, we borrow ideas from the field of active learning to optimally select a minimum subset of such images that yields accurate anatomy segmentation. The main contribution of this work is in designing a combined generative-discriminative model which: i) drives optimal selection of training data; and ii) increases segmentation accuracy. The optimal training set is constructed by finding unlabeled scans which maximize the disagreement between our two complementary probabilistic models, as measured by a modified version of the Jensen-Shannon divergence. Our algorithm is assessed on a database of 196 labeled clinical CT scans with high variability in resolution, anatomy, pathologies, etc. Quantitative evaluation shows that, compared with randomly selecting the scans to annotate, our method decreases the number of training images by up to 45%. Moreover, our generative model of body shape substantially increases segmentation accuracy when compared to either using the discriminative model alone or a generic smoothness prior (e.g. via a Markov Random Field).

  18. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  19. Influence of Arm Movement on Lesion Detection in PET/CT Imaging: Case Report

    Directory of Open Access Journals (Sweden)

    Yasemin Parlak

    2015-06-01

    Full Text Available Arm movement after the CT scan is a common artifact in PET/CT scanning. Motion artifacts may lead to difficulties in interpreting PET/CT images accurately. We report a 66 year old male patient with gastric cancer who underwent PET/CT for primary staging. He had a previous history of papillary thyroid cancer. In PET scan, there were striking cold artifacts at the level of arms. This is a classical sign of an accidental arm motion. A second scan was performed with the arms down due to the history of papillary thyroid cancer. The results were discussed.

  20. Image scanning microscopy with radially polarized light

    Science.gov (United States)

    Xiao, Yun; Zhang, Yunhai; Wei, Tongda; Huang, Wei; Shi, Yaqin

    2017-03-01

    In order to improve the resolution of image scanning microscopy, we present a method based on image scanning microscopy and radially polarized light. According to the theory of image scanning microscopy, we get the effective point spread function of image scanning microscopy with the longitudinal component of radially polarized light and a 1 AU detection area, and obtain imaging results of the analyzed samples using this method. Results show that the resolution can be enhanced by 7% compared with that in image scanning microscopy with circularly polarized light, and is 1.54-fold higher than that in confocal microscopy with a pinhole of 1 AU. Additionally, the peak intensity of ISM is 1.54-fold higher than that of a confocal microscopy with a pinhole of 1 AU. In conclusion, the combination of the image scanning microscopy and the radially polarized light could improve the resolution, and it could realize high-resolution and high SNR imaging at the same time.

  1. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  2. The Influence of Perfusion Values of Renal Cortex on Altering Image Frequency and Slice Thickness at CT Scan%扫描频率和层厚选择对肾皮质CT灌注参数值的影响

    Institute of Scientific and Technical Information of China (English)

    王琦; 时高峰; 王士杰; 田志辉

    2011-01-01

    目的 研究选择不同扫描频率和层厚对肾皮质CT灌注参数值的影响.方法 15例志愿者行肾脏CT灌注扫描,扫描时间为32 s.扫描层厚为5 mm,重建层厚2.5 mm.采用cine扫描模式完成扫描.然后依据间隔1 s、2 s、3 s分别选取一系列图像进行灌注分析,观察不同时间间隔灌注参数血流量(BF)、血容量(BV)、平均通过时间(MTT)、毛细血管表面通透性(PS)4项灌注参数值的差异.2种层厚的对照研究采用单变量计量资料中的配对t检验;不同频率选择采用配伍设计的方差分析.结果 通过cine模式、层厚5 mm连续扫描获得肾皮质的BF、BV、MTT、PS参数值分别为(407.10±86.69) ml·min-1·100 ml-1、(21.59±3.93) ml/100 g、(3.37±0.65) s、(56.42±16.30) ml·min-1·100 ml-1.与层厚为2.5 mm肾皮质的灌注参数值比较,不同层厚BF、BV、MTT和PS组间均无统计学意义(P>0.05).另与间隔1 s、间隔2 s、间隔3 s的肾皮质灌注参数值比较,前3种扫描时间间隔对BF、BV及PS灌注参数影响不大(P>0.05).间隔3 s的图像较少,得到的各项灌注参数值均明显不同于其他的序列,且相关性较差.结论 对肾皮质CT灌注成像,间隔1 s或2 s是值得提倡的扫描模式.5 mm和2.5 mm层厚的选择对CT灌注参数值没有影响.%Objective To study the influcnce of perfusion values of renal cortex on image frequency and slice thickness at CT scan . Methods 15 volunteers underwent renal CT cine perfusion during 32 second with 5 mm slice thickness and reconstructed 2. 5 mm slice thickness. The series of images in the interval at 1,2 and 3 second were chosen to analyse the blood flow(BF) , blood volume( BV) , mean transit time ( MTT) , permeability surface ( PS) of the renal cortex. The comparison between 2. 5 mm and 5 mm slice thickness was analayzed with paired t-test for depcndent samples. The comparison of the different image frequency was analayzed with two-way analysis of variance( ANOVA) and linear

  3. A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2

    Directory of Open Access Journals (Sweden)

    Sierink Joanne C

    2012-03-01

    Full Text Available Abstract Background Computed tomography (CT scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients. Methods/design The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED. All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness. Discussion The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning

  4. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  5. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  6. Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose.

    Science.gov (United States)

    Struffert, Tobias; Hertel, Victoria; Kyriakou, Yannis; Krause, Jens; Engelhorn, Tobias; Schick, Bernhard; Iro, Heinrich; Hornung, Joachim; Doerfler, Arnd

    2010-04-01

    Cochlear implantation assessment is possible using commercially available standard flat-detector computed tomography (FD-CT) protocols. Image quality is superior to multislice CT (MSCT). The radiation dose of FD-CT is lower in comparison with MSCT standard protocols and may therefore overcome the limitations of MSCT in the evaluation of cochlear implants. FD-CT offers higher spatial resolution than MSCT. Our objective was to compare the image quality of FD-CT to conventional MSCT in the visualization of a cochlear implant electrode array with respect to radiation exposure. An isolated temporal bone specimen was scanned using a commercially available FD-CT system and a 4 and 64 row MSCT scanner. Different scanning protocols were used. Image quality was assessed by four independent readers using a scoring system with different criteria describing delineation of the cochlea and the electrode array, image noise and spatial resolution. Radiation dose was measured using the CT dose index (CTDI) and a 16 cm acrylic phantom. Image quality was rated superior for FD-CT for all criteria by all readers. Single electrode contacts were only visible in FD-CT and assessment of implant position was improved by FD-CT. The radiation dose of FD-CT was half that of MSCT standard protocols.

  7. Computed tomographic (CT) scans in cerebral palsy (CP)

    Energy Technology Data Exchange (ETDEWEB)

    Kolawole, T.M.; Patel, P.J. (King Saud Univ., Riyadh (Saudi Arabia). Dept. of Radiology); Mahdi, A.H. (King Saud Univ., Riyadh (Saudi Arabia). Dept. of Paediatrics)

    1989-11-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.).

  8. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    Science.gov (United States)

    Chen, Yang; Yin, Xindao; Shi, Luyao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis; Toumoulin, Christine

    2013-08-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors.

  9. A comparative study for the effectiveness of the image by multiphase CT enterography among three scan phases%不同扫描时相小肠CT造影显示效能研究

    Institute of Scientific and Technical Information of China (English)

    李京津; 徐国萍; 夏庆来; 刘莹莹; 张雪宁; 牛冬梅; 刘梁生

    2015-01-01

    Objective To evaluate the influence of the CT enterography (CTE) in different scan phases of small intesti⁃nal wall and arteriovenous vessels, and to confirm the diagnostic efficiency thereof. Methods A total of 286 patients under⁃went CTE were collected, and their CT image of three scan phases, including 20 s, 40 s and 60 s after injection, were record⁃ed. Values of reinforcement of the intestinal wall and arteriovenous enhancing degree in all phases were collected. A statisti⁃cal analysis was used to confirm the best phase for showing the structure. The diagnostic efficiency of the best phase of CT image was evaluated for the clinical diagnosis of small intestine and vascular lesions. Results (1) The CT value of the small intestinal wall in the intestinal phase was significantly higher than other two phases (Pintestinal phase, and there is no statistical difference between the intestinal phase and oth⁃er two phases. The result of CT value of ileum vein showed that intestinal phase>portal phase>arterial phase (P<0.05). (3) The sensitivity was 95.8%, the specificity was 94.9%, the accuracy was 95.1%, the positive predictive value was 79.3%and the negative predictive value was 99.1%using CT image of intestinal period for diagnosing small intestinal diseases. (4) The intestinal period showed small intestinal lesions and confirmed by pathology including 22 cases of small intestinal lympho⁃ma, 10 cases of stromal tumor, 1 case adenoma, cavernous 3 cases hemangioma and 8 cases of Crohn's disease. The diagno⁃sis of hemangioma should be combined with arterial phase. Conclusion Small intestinal wall and blood vessels have better display performance in the intestinal phase of multiphase CT enterography, using the arterial phase and intestinal phase scan⁃ning, we can make an accurate diagnosis for the majority of small intestinal diseases.%目的:比较CT造影在不同扫描时相下对小肠肠壁及血管的显示效果,确定最佳扫描时相,评

  10. Correlation between the Degree and Severity of Symptoms and CT scan Changes in Chronic Rhinosinusitis (CRS

    Directory of Open Access Journals (Sweden)

    H. Moghaddasi

    2008-01-01

    Full Text Available Background/Objective: find out whether any correlation exists between the degree and severity of symptoms as assessed by the SNOT-20 questionnaire and CT scan changes as graded by Lund-Mackay scoring system in chronic rhinosinusitis (CRS."nPatients and Methods: Fifties patients attending the otolaryngology department and diagnosed with CRS were prospectively entered in this study. All patients had their CT scans graded by using the Lund-Mackay  with the sino-nasal outcome questionnaire (SNOT-20. Correlation analysis was conducted to determine whether the CT scan stage as assigned by Lund Mackay staging system correlated with the SNOT-20 scores."nResults: The mean age of our patients was 32.4±8.5 and 32(64% of them were male and 18(36% were female. The mean SNOT-20 was 45±8.7 (29-67 and the mean Lund-Mackay sinus score was 18.5±5 (8- 24.The mean SNOT-20 score was higher for postnasal drip (PND and facial pain, and the lowest mean scores were for dizziness and ear pain. The Pearson's correlation coefficient confirmed that there was a good correlation between SNOT-20 scores and CT scores (Pearson correlation coefficient 0.77; P value, 0.0001."nConclusion: Patients with higher symptom scores are more likely to have CT imaging evidence of rhinosinusitis. In patients with isolated sleep or systematic symptoms, the likelihood of rhinosinusitis is less, even if symptoms are severe. Therefore, in these patients, sinus CT-scan should be considered before treatment to establish the diagnosis of chronic rhinosinusitis due to that a number of these patients may be doing not have rhinosinusitis.

  11. CT versus MR in neonatal brain imaging at term

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Richard L.; Robson, Caroline D.; Zurakowski, David; Antiles, Sharon; Strauss, Keith; Mulkern, Robert V. [Department of Radiology, Children' s Hospital Medical Center, Harvard Medical School, 300 Longwood Avenue, MA 02115, Boston (United States)

    2003-07-01

    Recent reports have highlighted the lifetime risk of malignancy from using ionizing radiation in pediatric imaging. Computed tomography (CT), which uses ionizing radiation, is employed extensively for neonatal brain imaging of term infants. Magnetic resonance (MR) provides an alternative that does not use ionizing radiation. The purpose of this study was to assess the cross-modality agreement and interobserver agreement of CT and MR brain imaging of the term or near-term neonate. Brain CT and MR images of 48 neonates were retrospectively reviewed by two pediatric neuroradiologists. CT and MR examinations had been obtained within 72 h of one another in all patients. CT was obtained with 5 mm collimation (KV=120, mAs=340). MR consisted of T1-weighted imaging (TR/TE=300/14; 4-mm slice thickness/1-mm gap), T2-weighted imaging (TR/TE/etl= 3000/126/16; 4-mm slice thickness/1-mm gap), and line scan diffusion imaging (LSDI) (TR/TE/b factor=1258/63/750; nominal 4-mm slice thickness/3-mm gap). The brain was categorized as normal or abnormal on both CT and MR. Ischemic injury was the most common brain abnormality demonstrated. McNemar's test indicated no significant difference between CT and MR test results for reader 1 (P=0.22) or reader 2 (P=0.45). The readers agreed on the presence or absence of abnormality on CT in 40 patients (83.3%) and on MR in 45 patients (93.8%). For CT, the kappa coefficient indicated excellent interobserver agreement ({kappa}=0.68), although the lower limit of the 95% confidence interval extends to {kappa}=0.55, which indicates only good-to-moderate agreement. For MR, the kappa coefficient indicated almost perfect interobserver agreement ({kappa}=0.88) with the 95% confidence interval extending to a lower limit of {kappa}=0.76, which represents excellent agreement. Because MR demonstrates findings similar to CT and has greater interobserver agreement, it appears that MR is a superior test to CT in determining brain abnormalities in the term

  12. Treatment of alzheimer disease with CT scans - a case report

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M. [Cuttler & Associates Inc., Vaughan, Ontario (Canada); Moore, E.R. [Dow Chemical Co., Midland, MI (United States); Hosfeld, V.D. [MidMichigan Health, Midland, MI (United States); Nadolski, D.L. [Midland Internal Medicine Associates PC, Midland, MI (United States)

    2016-03-15

    Alzheimer disease (AD) primarily affects older adults. This neurodegenerative disorder is the most common cause of dementia and is a leading source of their morbidity and mortality. U.S. patient care costs are about 200 billion dollars and will more than double by 2040. This case report describes the remarkable improvement of an advanced AD patient in hospice, who received five CT scans of the brain, about 40 mGy each, over a period of three months. The mechanism appears to be radiation-induced up-regulation of the patient's adaptive protection systems against AD, which partially restored cognition, memory, speech, movement, and appetite. (author)

  13. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  14. The pros and cons of intraoperative CT scan in evaluation of deep brain stimulation lead implantation: A retrospective study

    Science.gov (United States)

    Servello, Domenico; Zekaj, Edvin; Saleh, Christian; Pacchetti, Claudio; Porta, Mauro

    2016-01-01

    Background: Deep brain stimulation (DBS) is an established therapy for movement disorders, such as Parkinson's disease (PD), dystonia, and tremor. The efficacy of DBS depends on the correct lead positioning. The commonly adopted postoperative radiological evaluation is performed with computed tomography (CT) scan and/or magnetic resonance imaging (MRI). Methods: We conducted a retrospective study on 202 patients who underwent DBS from January 2009 to October 2013. DBS indications were PD, progressive supranuclear palsy, tremor, dystonia, Tourette syndrome, obsessive compulsive disorder, depression, and Huntington's disease. Preoperatively, all patients underwent brain MRI and brain CT scan with the stereotactic frame positioned. The lead location was confirmed intraoperatively with CT. The CT images were subsequently transferred to the Stealth Station Medtronic and merged with the preoperative planning. On the first or second day after, implantation we performed a brain MRI to confirm the correct position of the lead. Results: In 14 patients, leads were in suboptimal position after intraoperative CT scan positioning. The cases with alteration in the Z-axis were corrected immediately under fluoroscopic guidance. In all the 14 patients, an immediate repositioning was done. Conclusions: Based on our data, intraoperative CT scan is fast, safe, and a useful tool in the evaluation of the position of the implanted lead. It also reduces the patient's discomfort derived from the transfer of the patient from the operating room to the radiological department. However, intraoperative CT should not be considered as a substitute for postoperative MRI. PMID:27583182

  15. Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

    Science.gov (United States)

    Parsa, A; Ibrahim, N; Hassan, B; Motroni, A; van der Stelt, P; Wismeijer, D

    2013-01-01

    The aim of this study was to determine the grey value variation at the implant site with different scan settings, including field of view (FOV), spatial resolution, number of projections, exposure time and dose selections in two cone beam CT (CBCT) systems and to compare the results with those obtained from a multislice CT system. A partially edentulous human mandibular cadaver was scanned by three CT modalities: multislice CT (MSCT) (Philips, Best, the Netherlands), and two CBCT systems: (Accuitomo 170(®), Morita, Japan) and (NewTom 5G(®), QR, Verona, Italy). Using different scan settings 36 and 24 scans were obtained from the Accuitomo and the NewTom, respectively. The scans were converted to digital imaging and communications in medicine 3 format. The analysis of the data was performed using 3Diagnosys(®) software (v. 3.1, 3diemme, Cantù, Italy) and Geomagic studio(®) 2012 (Morrisville, NC). On the MSCT scan, one probe designating the site for pre-operative implant placement was inserted. The inserted probe on MSCT was transformed to the same region on each CBCT scan using a volume-based three-dimensional registration algorithm. The mean voxel grey value of the region around the probe was derived separately for each CBCT. The influence of scanning parameters on the measured mean voxel grey values was assessed. Grey values in both CBCT systems significantly deviated from Hounsfield unit values measured with MSCT (p = 0.0001). In both CBCT systems, scan FOV and spatial resolution selections had a statistically significant influence on grey value measurements (p = 0.0001). The number of projections selection had a statistically significant influence in the Accuitomo system (p = 0.0001) while exposure time and dose selections had no statistically significant influence on grey value measurements in the NewTom (p = 0.43 and p = 0.37, respectively). Grey-level values from CBCT images are influenced by device and scanning settings.

  16. Light scattering in optical CT scanning of Presage dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y; Adamovics, J; Cheeseborough, J C; Chao, K S; Wuu, C S, E-mail: yx2010@columbia.ed

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS' optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  17. Reliability of visual assessment of non-contrast CT, CT angiography source images and CT perfusion in patients with suspected ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Tom van Seeters

    Full Text Available BACKGROUND AND PURPOSE: Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA rule and the Alberta Stroke Program Early CT Score (ASPECTS for different CT modalities in patients suspected of acute ischemic stroke. METHODS: We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement. RESULTS: Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps. Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps. CONCLUSION: Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging.

  18. PET CT imaging in extramedullary hematopoiesis and lung cancer surprise in a case with thalassemia intermedia

    Directory of Open Access Journals (Sweden)

    Semra Paydaş

    2011-03-01

    Full Text Available Extramedullary hematopoiesis (EMH is the production of hematopoietic precursors outside the bone marrow cavity, and it causes mass effects according to its localization. Magnetic resonance imaging (MRI and/or computed tomography (CT scans are used most commonly to detect EMH foci. We report herein a case with thalassemia intermedia causing paravertebral mass associated with EMH detected by CT scan. We further evaluated the case with positron emission tomography (PET CT, and lung cancer, which was not revealed in the CT scan, was detected coincidentally.

  19. Optimization of megavoltage CT scan registration settings for brain cancer treatments on tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Woodford, Curtis; Yartsev, Slav; Van Dyk, Jake [London Regional Cancer Program, London Health Sciences Centre, 790 Commissioners Road East, London, Ontario (Canada)

    2007-04-21

    This study aims to determine the settings that provide the optimal clinical accuracy and consistency for the registration of megavoltage CT (MVCT) with planning kilovoltage CT image sets on the Hi-ART tomotherapy system. The systematic offset between the MVCT and the planning kVCT was determined by registration of multiple MVCT scans of a head phantom aligned with the planning isocentre. Residual error vector lengths and components were used to quantify the alignment quality for the phantom shifted by 5 mm in different directions obtained by all 27 possible combinations of MVCT inter-slice spacing, registration techniques and resolution. MVCT scans with normal slices are superior to coarse slices for registration of shifts in the superior-inferior, lateral and anterior-posterior directions. Decreasing the scan length has no detrimental effect on registration accuracy as long as the scan lengths are larger than 24 mm. In the case of bone technique and fine resolution, normal and fine MVCT scan slice spacing options give similar accuracy, so normal mode is preferable due to shorter procedure and less delivered dose required for patient set-up. A superior-inferior field length of 24-30 mm, normal slice spacing, bone technique, and fine resolution is the optimum set of registration settings for MVCT scans of a Rando head phantom acquired with the Hi-ART tomotherapy system, provided the registration shifts are less than 5 mm. (note)

  20. Imaging analysis of different types of liver metastases of colorectal carcinoma with CT contrast enhancement scan%结肠癌肝转移瘤的不同CT增强类型影像特征分析

    Institute of Scientific and Technical Information of China (English)

    邵文尚; 李丹; 迟宇; 张清波

    2014-01-01

    Objective To summarize the imaging features of colon carcinoma liver metastasis by CT contrast enhancement and discusses rare manifestation of the lesions. Methods 177 liver metastatic lesions from colon carcinoma in 80 patients were retrospectively analyzed using three phase enhanced CT scanning. The imaging features of the various lesions were summarized. Results Among the 177 metastatic lesions,93 annular enhanced ones, accounting for 52.5%,56 focal nodular enhanced ones,accounting for 31.6%,and wheel sign,loofah sign, calcified bull eye sign,accounting for 15.9%,were respectively found. The annular enhanced lesions are characterized by smooth outer walls and rough inner walls. The uneven walls, which thickness being between 0.2-8mm(average 1.8mm),were heterogeneous enhanced. Conclusion Most liver metastatic lesions of colon carcinoma demonstrate annular and nodular enhanced on CT images. While some lesions show special features, they have some special enhanced characteristics different from other liver lesions,which might be helpful to improve diagnosis accurate rate.%目的:总结CT增强扫描所见结肠癌肝转移病灶CT表现,探讨少见类型的特征表现,以提高对结肠癌肝转移的进一步认识。方法回顾性分析经我院检查确诊的结肠癌肝转移病例共80例177个病灶。所有患者接受16排CT常规三期增强扫描,对图像进行分析。结果177个转移灶中:CT增强表现环状强化者93灶,占52.5%;表现为结节状强化者56灶,占31.6%;表现为车轮征、丝瓜瓤征、钙化性牛眼征者28灶,占15.9%。环形强化的特征为外壁光滑,内壁毛糙,壁厚薄不均,为0.2~8mm,平均1.8mm,壁强化不均。结论结肠癌肝转移CT强化主要表现为环状强化和结节状强化,但也有部分转移瘤影像表现较特殊,其强化有一定的特征表现可与其他病变鉴别,这些特征有助于提高诊断的准确性,减少误诊率。

  1. Comparative analysis of realistic CT-scan and simplified human airway models in airflow simulation.

    Science.gov (United States)

    Johari, Nasrul Hadi; Osman, Kahar; Helmi, Nor Harris N; Abdul Kadir, Mohammed A Rafiq

    2015-01-01

    Efforts to model the human upper respiratory system have undergone many phases. Geometrical proximity to the realistic shape has been the subject of many research projects. In this study, three different geometries of the trachea and main bronchus were modelled, which were reconstructed from computed tomography (CT) scan images. The geometrical variations were named realistic, simplified and oversimplified. Realistic refers to the lifelike image taken from digital imaging and communications in medicine format CT scan images, simplified refers to the reconstructed image based on natural images without realistic details pertaining to the rough surfaces, and oversimplified describes the straight wall geometry of the airway. The characteristics of steady state flows with different flow rates were investigated, simulating three varied physical activities and passing through each model. The results agree with previous studies where simplified models are sufficient for providing comparable results for airflow in human airways. This work further suggests that, under most exercise conditions, the idealised oversimplified model is not favourable for simulating either airflow regimes or airflow with particle depositions. However, in terms of immediate analysis for the prediction of abnormalities of various dimensions of human airways, the oversimplified techniques may be used.

  2. SPECT/CT and tumour imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abikhzer, Gad [Rambam Health Care Campus, Department of Nuclear Medicine, Haifa (Israel); Keidar, Zohar [Rambam Health Care Campus, Department of Nuclear Medicine, Haifa (Israel); Technion - Israel Institute of Technology, The Ruth and Bruce Rappaport Faculty of Medicine, Haifa (Israel)

    2014-05-15

    Scintigraphic techniques are sensitive imaging modalities in the diagnosis and follow-up of cancer patients providing the functional and metabolic activity characteristics of the tumour. Hybrid SPECT/CT improves the diagnostic accuracy of these well-established imaging techniques by precise anatomical localization and characterization of morphological findings, differentiation between foci of physiological and pathological tracer uptake, resulting in a significant impact on patient management and more definitive interpretations. The use of SPECT/CT has been studied in a variety of applications in tumour imaging which are reviewed in this article. By combining functional and anatomical information in a single imaging session, SPECT/CT has become a one-stop cancer imaging modality. (orig.)

  3. Automated delineation of stroke lesions using brain CT images

    Directory of Open Access Journals (Sweden)

    Céline R. Gillebert

    2014-01-01

    Full Text Available Computed tomographic (CT images are widely used for the identification of abnormal brain tissue following infarct and hemorrhage in stroke. Manual lesion delineation is currently the standard approach, but is both time-consuming and operator-dependent. To address these issues, we present a method that can automatically delineate infarct and hemorrhage in stroke CT images. The key elements of this method are the accurate normalization of CT images from stroke patients into template space and the subsequent voxelwise comparison with a group of control CT images for defining areas with hypo- or hyper-intense signals. Our validation, using simulated and actual lesions, shows that our approach is effective in reconstructing lesions resulting from both infarct and hemorrhage and yields lesion maps spatially consistent with those produced manually by expert operators. A limitation is that, relative to manual delineation, there is reduced sensitivity of the automated method in regions close to the ventricles and the brain contours. However, the automated method presents a number of benefits in terms of offering significant time savings and the elimination of the inter-operator differences inherent to manual tracing approaches. These factors are relevant for the creation of large-scale lesion databases for neuropsychological research. The automated delineation of stroke lesions from CT scans may also enable longitudinal studies to quantify changes in damaged tissue in an objective and reproducible manner.

  4. CT脑灌注成像临床诊断急性脑梗死价值评价与平扫CT值差值的测量价值%Value Evaluation on Clinical Diagnosis of CT Cerebral Perfusion Imaging on Acute Cerebral infarction and Measurement Value of Difference Value of Plain Scan CT Value

    Institute of Scientific and Technical Information of China (English)

    余东

    2015-01-01

    Objective This Paper is to explore the application value of CT perfusion imaging and differential value of measured CT value in the diagnosis of acute cerebral infarction. Methods Thirty six patients with acute cerebral infarction admitted the Radiology Department of the Hospital were selected as research subjects, retrospective analysis and summary were conducted according to clinical data. CT plaint scan and brain CT perfusion imaging were made respectively, The time to peak (TIP), cerebral blood flow (CBF) and cerebral blood volume (CBV) of CT perfusion imaging were evaluated, the difference of CT value on both sides of symmetric positions was measured. In addition, 36 patients with no brain disease and normal nervous function were divided into the control group, and diagnostic value of the difference between CT perfusion imaging and CT measurement value in acute cerebral infarction was analyzed. Results It is visually found that there were 17 patients with suspicious lesions with the sensitivity at 47.2%, and it was found that there were 28 patients with suspicious lesions by measuring CT value difference. It was found that the CTP of 3 patients was normal CT perfusion imaging examination, and such 2 patients were finally diagnosed to suffer from transient ischemic attack, and others were abnomal, rCBF, rCBV and rTTP changed obviously, the comparison in lesion center and perimeter and controlled side satisfied p<0.05, and the differences were statistically significant. Conclusion CT perfusion imaging and the difference value in CT value measurement delivers high application value in the diagnosis of acute cerebral infarction, and it is capable of diagnosing cerebral infarction in early differential diagnosis, the infarct area and ischemic penumbra area may be differentiated via through quantitative analysis, providing important basis for clinical determination on the existence of infarct and development of therapeutic schedule.%目的:探讨CT灌注成像

  5. Development of 1-year-old computational phantom and calculation of organ doses during CT scans using Monte Carlo simulation.

    Science.gov (United States)

    Pan, Yuxi; Qiu, Rui; Gao, Linfeng; Ge, Chaoyong; Zheng, Junzheng; Xie, Wenzhang; Li, Junli

    2014-09-21

    With the rapidly growing number of CT examinations, the consequential radiation risk has aroused more and more attention. The average dose in each organ during CT scans can only be obtained by using Monte Carlo simulation with computational phantoms. Since children tend to have higher radiation sensitivity than adults, the radiation dose of pediatric CT examinations requires special attention and needs to be assessed accurately. So far, studies on organ doses from CT exposures for pediatric patients are still limited. In this work, a 1-year-old computational phantom was constructed. The body contour was obtained from the CT images of a 1-year-old physical phantom and the internal organs were deformed from an existing Chinese reference adult phantom. To ensure the organ locations in the 1-year-old computational phantom were consistent with those of the physical phantom, the organ locations in 1-year-old computational phantom were manually adjusted one by one, and the organ masses were adjusted to the corresponding Chinese reference values. Moreover, a CT scanner model was developed using the Monte Carlo technique and the 1-year-old computational phantom was applied to estimate organ doses derived from simulated CT exposures. As a result, a database including doses to 36 organs and tissues from 47 single axial scans was built. It has been verified by calculation that doses of axial scans are close to those of helical scans; therefore, this database could be applied to helical scans as well. Organ doses were calculated using the database and compared with those obtained from the measurements made in the physical phantom for helical scans. The differences between simulation and measurement were less than 25% for all organs. The result shows that the 1-year-old phantom developed in this work can be used to calculate organ doses in CT exposures, and the dose database provides a method for the estimation of 1-year-old patient doses in a variety of CT examinations.

  6. Three modality image registration of brain SPECT/CT and MR images for quantitative analysis of dopamine transporter imaging

    Science.gov (United States)

    Yamaguchi, Yuzuho; Takeda, Yuta; Hara, Takeshi; Zhou, Xiangrong; Matsusako, Masaki; Tanaka, Yuki; Hosoya, Kazuhiko; Nihei, Tsutomu; Katafuchi, Tetsuro; Fujita, Hiroshi

    2016-03-01

    Important features in Parkinson's disease (PD) are degenerations and losses of dopamine neurons in corpus striatum. 123I-FP-CIT can visualize activities of the dopamine neurons. The activity radio of background to corpus striatum is used for diagnosis of PD and Dementia with Lewy Bodies (DLB). The specific activity can be observed in the corpus striatum on SPECT images, but the location and the shape of the corpus striatum on SPECT images only are often lost because of the low uptake. In contrast, MR images can visualize the locations of the corpus striatum. The purpose of this study was to realize a quantitative image analysis for the SPECT images by using image registration technique with brain MR images that can determine the region of corpus striatum. In this study, the image fusion technique was used to fuse SPECT and MR images by intervening CT image taken by SPECT/CT. The mutual information (MI) for image registration between CT and MR images was used for the registration. Six SPECT/CT and four MR scans of phantom materials are taken by changing the direction. As the results of the image registrations, 16 of 24 combinations were registered within 1.3mm. By applying the approach to 32 clinical SPECT/CT and MR cases, all of the cases were registered within 0.86mm. In conclusions, our registration method has a potential in superimposing MR images on SPECT images.

  7. Initial experience with optical-CT scanning of RadBall Dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M; Clift, C; Thomas, A; Farfan, E; Foley, T; Jannik, T; Adamovics, J; Holmes, C; Stanley, S, E-mail: Mark.Oldham@Duke.ed

    2010-11-01

    The RadBall dosimeter is a novel device for providing 3-D information on the magnitude and distribution of contaminant sources of unknown radiation in a given hot cell, glovebox, or contaminated room. The device is presently under evaluation by the National Nuclear Lab (NNL, UK) and the Savannah River National Laboratory (SRNL, US), for application as a diagnostic device for such unknown contaminants in the nuclear industry. A critical component of the technique is imaging the dose distribution recorded in the RadBall using optical-CT scanning. Here we present our initial investigations using the Duke Mid-sized Optical-CT Scanner (DMOS) to image dose distributions deposited in RadBalls exposed to a variety of radiation treatments.

  8. Intrapartum FHR monitoring and neonatal CT brain scan

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Yoshiki; Ukita, Masahiko; Nakada, Eizo (Kurashiki Central Hospital, Okayama (Japan))

    1982-12-01

    The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no variability resulted in severe neonatal brain edema. Four cases with variable deceleration and increased variability resulted in mild neonatal brain edema. Two cases with late deceleration and decreased variability resulted in no neonatal brain edema.

  9. Clinical evaluation of dynamic CT scan of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Tokuda, Masamichi

    1984-09-01

    The clinical usefulness of dynamic CT scans (DCT) of the pancreas was evaluated in 62 normal cases, 9 cases of acute pancreatitis, 24 cases of chronic pancreatitis and 43 cases of carcinoma of the pancreas. The normal pancreas was intensely and homogeneously enhanced on DCT, and peripancreatic vessels were clearly demonstrated, especially the gastroduodenal artery (98.4%). DCT was useful to demonstrate vascular lesions, associated with pancreatitis such as pseudoaneurysm. Although the carcinoma of the pancreas showed poor contrast enhancement on conventional enhanced CT (CCT), 37.2% showed intense contrast enhancement on DCT. Visualization of the gastroduodenal artery by DCT is helpful to decide the extent of tumor. DCT is superior to CCT in demonstrating collateral veins caused by tumor invasion to the portal system in carcinoma. DCT was approximately as accurate as angiography (92.6%) in evaluating tumor invasion to the portal system. DCT is a useful and minimally invasive modality in assessing the resectability of pancreatic carcinoma. DCT may eliminate angiography and surgery in unresectable cases. (author).

  10. A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Yonekawa, Hiroyuki; Ohashi, Masami; Miyashita, Souji; Gotoh, Mizuho; Nemoto, Satohiko; Kikuchi, Hideki (Azabu Triology Hospital, Sapporo (Japan)); Sakai, Noboru; Inuyama, Yukio

    1993-09-01

    The current availability of 3 dimensional (3-D) imaging from Computed Tomography (CT) has yielded new anatomical information and pre- and postoperative evaluations. However, little discussion as to the 3-D structural image of the temporal bone has been reported because conventional CT does provide sufficient data to produce such images. The helical scanning CT gathers continuous and multiple slice image data since it consists of an X-ray tube that continuously rotates around the patient while the patient moves continuously into the CT scanner. Thus, application of the helical scanning CT has made it possible to reconstruct 3-D images of the minute and complicated structure of the temporal bone. We evaluated 3-D images from 9 typical cases, examined from February to October 1992. As a result, we found that the 3-D images reconstructed with this system are useful for evaluation of the postoperative state of tympanoplasty, the diagnosis of anomalies of the bony labyrinth, and examining the extent of bone destruction induced by trauma, cholesteatoma, etc. (author).

  11. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  12. Imaging of jaw with dental CT software program: Normal Anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myong Gon; Seo, Kwang Hee; Jung, Hak Young; Sung, Nak Kwan; Chung, Duk Soo; Kim, Ok Dong [School of Medicine, Taegu Catholic University, Taegu (Korea, Republic of); Lee, Young Hwan [Taegu Armed Forces General Hospital, Taegu (Korea, Republic of)

    1994-07-15

    Dental CT software program can provide reformatted cross-sectional and panoramic images that cannot be obtained with conventional axial and direct coronal CT scan. The purpose of this study is to describe the method of the technique and to identify the precise anatomy of jaw. We evaluated 13 mandibles and 7 maxillae of 15 subjects without bony disease who were being considered for endosseous dental implants. Reformatted images obtained by the use of bone algorithm performed on GE HiSpeed Advantage CT scanner were retrospectively reviewed for detailed anatomy of jaw. Anatomy related to neurovascular bundle(mandibular foramen, inferior alveolar canal, mental foramen, canal for incisive artery, nutrient canal, lingual foramen and mylohyoid groove), muscular insertion(mylohyoid line, superior and inferior genial tubercle and digastric fossa) and other anatomy(submandibular fossa, sublingual fossa, contour of alveolar process, oblique line, retromolar fossa, temporal crest and retromolar triangle) were well delineated in mandible. In maxilla, anatomy related to neurovascular bundle(greater palatine foramen and groove, nasopalatine canal and incisive foramen) and other anatomy(alveolar process, maxillary sinus and nasal fossa) were also well delineated. Reformatted images using dental CT software program provided excellent delineation of the jaw anatomy. Therefore, dental CT software program can play an important role in the preoperative assessment of mandible and maxilla for dental implants and other surgical conditions.

  13. Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans

    Science.gov (United States)

    Shahzad, Rahil; Bos, Daniel; Budde, Ricardo P. J.; Pellikaan, Karlijn; Niessen, Wiro J.; van der Lugt, Aad; van Walsum, Theo

    2017-05-01

    Early structural changes to the heart, including the chambers and the coronary arteries, provide important information on pre-clinical heart disease like cardiac failure. Currently, contrast-enhanced cardiac computed tomography angiography (CCTA) is the preferred modality for the visualization of the cardiac chambers and the coronaries. In clinical practice not every patient undergoes a CCTA scan; many patients receive only a non-contrast-enhanced calcium scoring CT scan (CTCS), which has less radiation dose and does not require the administration of contrast agent. Quantifying cardiac structures in such images is challenging, as they lack the contrast present in CCTA scans. Such quantification would however be relevant, as it enables population based studies with only a CTCS scan. The purpose of this work is therefore to investigate the feasibility of automatic segmentation and quantification of cardiac structures viz whole heart, left atrium, left ventricle, right atrium, right ventricle and aortic root from CTCS scans. A fully automatic multi-atlas-based segmentation approach is used to segment the cardiac structures. Results show that the segmentation overlap between the automatic method and that of the reference standard have a Dice similarity coefficient of 0.91 on average for the cardiac chambers. The mean surface-to-surface distance error over all the cardiac structures is 1.4+/- 1.7 mm. The automatically obtained cardiac chamber volumes using the CTCS scans have an excellent correlation when compared to the volumes in corresponding CCTA scans, a Pearson correlation coefficient (R) of 0.95 is obtained. Our fully automatic method enables large-scale assessment of cardiac structures on non-contrast-enhanced CT scans.

  14. Experiences of using a single post-contrast CT scan of the urinary tract after triphasic contrast injection

    Directory of Open Access Journals (Sweden)

    Phillip Carl Pretorius

    2011-12-01

    Full Text Available I was alerted to an article in Radiology Vol. 255 No. 2 (May 20101 by a colleague. The article, entitled ‘Kidney and urinary tract imaging: Triple-bolus multidetector CT urography as a one-stop shop – Protocol design, opacification, and image quality analysis’, clearly describes the technique, while the quotation below, from the article, summarises the findings: ‘We have shown that triple-bolus multidetector CT urography allowed visualization of renal parenchymal, excretory, and vascular contrast-enhancement phases in a single dose-efficient acquisition and provided sufficient opacification of the UUT, with simultaneous and adequate image quality of renal parenchyma and vascular anatomy.’ The main emphasis on this technique is to reduce the number of unnecessary CT scans when assessing the urinary tract. Our previous protocol for scanning the urinary tract for pathology included four phases: a pre-contrast, corticomedullary, nephrographic and delay excretory phase.

  15. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Davide; Agnoletti, Gabriella [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); Brunelle, Francis [University Paris Descartes, UFR Necker-Enfants Malades, Department of Pediatric Radiology, APHP, Paris (France); Sidi, Daniel; Bonnet, Damien [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); Ou, Phalla [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); University Paris Descartes, UFR Necker-Enfants Malades, Department of Pediatric Radiology, APHP, Paris (France)], E-mail: phalla.ou@nck.aphp.fr

    2009-09-15

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 {+-} 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 {+-} 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surge0008.

  16. Automatic Calibration Method of Voxel Size for Cone-beam 3D-CT Scanning System

    CERN Document Server

    Yang, Min; Liu, Yipeng; Men, Fanyong; Li, Xingdong; Liu, Wenli; Wei, Dongbo

    2013-01-01

    For cone-beam three-dimensional computed tomography (3D-CT) scanning system, voxel size is an important indicator to guarantee the accuracy of data analysis and feature measurement based on 3D-CT images. Meanwhile, the voxel size changes with the movement of the rotary table along X-ray direction. In order to realize the automatic calibration of the voxel size, a new easily-implemented method is proposed. According to this method, several projections of a spherical phantom are captured at different imaging positions and the corresponding voxel size values are calculated by non-linear least square fitting. Through these interpolation values, a linear equation is obtained, which reflects the relationship between the rotary table displacement distance from its nominal zero position and the voxel size. Finally, the linear equation is imported into the calibration module of the 3D-CT scanning system, and when the rotary table is moving along X-ray direction, the accurate value of the voxel size is dynamically expo...

  17. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2012-01-01

    This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...... into a standard image registration framework with a composition of a global affine and several free-form B-Spline transformations with increasing grid resolution. The proposed mass preserving registration method is compared to registration using the sum of squared intensity differences as a similarity function...... inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant...

  18. Evaluation of thin section CT scanning in the prone position of metastatic axillary lymphnodes for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Yasuhiro; Ogawa, Yasuhiro; Nishioka, Akihito; Inomata, Taisuke; Yoshida, Shoji; Toki, Taiichi [Kochi Medical School, Nangoku (Japan)

    1996-12-01

    A retrospective study was performed to determine whether thin section CT scanning in the prone position of the breast and the axilla yield useful information regarding the status of axillary lymph nodes in patients with breast cancer. Thirty-six patients with breast carcinomas were scanned preoperatively from the supraclavicular regions to the breast in the prone position with 5 mm sections. Axillary lymph nodes measuring {>=}5 mm on the short axis were considered abnormal. Correlation with axillary dissection was obtained in all patients, giving a positive predictive value for axillary metastases of 83.3%, with 88.2% sensitivity, 84.2% specificity, and 88.8% negative predictive value. We concluded that thin section CT scan in the prone position was an accurate predictor of axillary lymph node involvement. We made a phantom with lymph node swelling to evaluate whether CT scanning with 5 mm sections was necessary for detecting 5 mm swollen lymph nodes. We scanned the phantom with 5 mm and 10 mm sections. Twelve radiologists counted the swollen lymph nodes on 5 mm section images and 10 mm section images of the phantom. The average number of miscounts was 1.1 (miscount rate 6.8%) on 5 mm section and 2.8 (15%) on 10 mm sections. We conclued that 5 mm section CT scanning is superior for detecting 5 mm lymph nodes. (author)

  19. Image Analysis in CT Angiography

    NARCIS (Netherlands)

    Manniesing, R.

    2006-01-01

    In this thesis we develop and validate novel image processing techniques for the analysis of vascular structures in medical images. First a new type of filter is proposed which is capable of enhancing vascular structures while suppressing noise in the remainder of the image. This filter is based on

  20. The maxillomandibular ameloblastoma: CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Han, Moon Hee; Kim, Myung Jin; Chang, Kee Hyun [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-02-15

    We retrospectively performed this study to evaluate the characteristic findings of maxillomandibular ameloblastomas on CT and MR imaging. We reviewed histologically proved 12 cases of ameloblastomas, of which 7 cases were postoperative recurrent tumors, one of twelve cases was presumed ameloblastic carcinoma. Eleven cases were examined with CT and 3 cases with MR. The types were solid in 4, unicystic in 4, and mixed in the rest 4. CT and MRI of 11 ameloblastomas showed concentric expansile mass (n = 11), cortical bone thinning and focal bone destruction by the tumors (n = 9), well-margined, expansile destruction of surrounding sturctures (n = 9), focal bulging of the tumors (n = 6) and focal poorly-marginated invasion of tissue planes (n = 4). Ameloblastic carcinoma showed ill-defined irregular margin, aggressive invasion of surrounding structures and hematogeneous lung metastasis. Unerupted teeth or mural modules were found in unicystic ameloblastomas. All three tumors examined by MRI showed isointensity to muscle on T1 weighted images and slight hyperintensity on T2 weighted images. The wall, septa and solid portions of the tumors were strongly enhanced on MR imaging. There was no difference in CT ro MR finding between primary and recurrent tumors. Ameloblastomas showed solid, cystic or mixed pattern, and commonly well marginated expansile contour with local aggressiveness. Presence of mural nodules on CT in unicystic ameloblastoma with unerupted tooth was helpful in distinguishing ameloblastoma from dentigerous cyst.

  1. CT image segmentation using FEM with optimized boundary condition.

    Directory of Open Access Journals (Sweden)

    Hiroyuki Hishida

    Full Text Available The authors propose a CT image segmentation method using structural analysis that is useful for objects with structural dynamic characteristics. Motivation of our research is from the area of genetic activity. In order to reveal the roles of genes, it is necessary to create mutant mice and measure differences among them by scanning their skeletons with an X-ray CT scanner. The CT image needs to be manually segmented into pieces of the bones. It is a very time consuming to manually segment many mutant mouse models in order to reveal the roles of genes. It is desirable to make this segmentation procedure automatic. Although numerous papers in the past have proposed segmentation techniques, no general segmentation method for skeletons of living creatures has been established. Against this background, the authors propose a segmentation method based on the concept of destruction analogy. To realize this concept, structural analysis is performed using the finite element method (FEM, as structurally weak areas can be expected to break under conditions of stress. The contribution of the method is its novelty, as no studies have so far used structural analysis for image segmentation. The method's implementation involves three steps. First, finite elements are created directly from the pixels of a CT image, and then candidates are also selected in areas where segmentation is thought to be appropriate. The second step involves destruction analogy to find a single candidate with high strain chosen as the segmentation target. The boundary conditions for FEM are also set automatically. Then, destruction analogy is implemented by replacing pixels with high strain as background ones, and this process is iterated until object is decomposed into two parts. Here, CT image segmentation is demonstrated using various types of CT imagery.

  2. Childhood CT scans linked to leukemia and brain cancer later in life

    Science.gov (United States)

    Children and young adults scanned multiple times by computed tomography (CT), a commonly used diagnostic tool, have a small increased risk of leukemia and brain tumors in the decade following their first scan.

  3. Incorporating Radiology into Medical Gross Anatomy: Does the Use of Cadaver CT Scans Improve Students' Academic Performance in Anatomy?

    Science.gov (United States)

    Lufler, Rebecca S.; Zumwalt, Ann C.; Romney, Carla A.; Hoagland, Todd M.

    2010-01-01

    Radiological images show anatomical structures in multiple planes and may be effective for teaching anatomical spatial relationships, something that students often find difficult to master. This study tests the hypotheses that (1) the use of cadaveric computed tomography (CT) scans in the anatomy laboratory is positively associated with…

  4. Incorporating Radiology into Medical Gross Anatomy: Does the Use of Cadaver CT Scans Improve Students' Academic Performance in Anatomy?

    Science.gov (United States)

    Lufler, Rebecca S.; Zumwalt, Ann C.; Romney, Carla A.; Hoagland, Todd M.

    2010-01-01

    Radiological images show anatomical structures in multiple planes and may be effective for teaching anatomical spatial relationships, something that students often find difficult to master. This study tests the hypotheses that (1) the use of cadaveric computed tomography (CT) scans in the anatomy laboratory is positively associated with…

  5. Disease quantification on PET/CT images without object delineation

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Wu, Caiyun; Fitzpatrick, Danielle; Winchell, Nicole; Schuster, Stephen J.; Torigian, Drew A.

    2017-03-01

    The derivation of quantitative information from images to make quantitative radiology (QR) clinically practical continues to face a major image analysis hurdle because of image segmentation challenges. This paper presents a novel approach to disease quantification (DQ) via positron emission tomography/computed tomography (PET/CT) images that explores how to decouple DQ methods from explicit dependence on object segmentation through the use of only object recognition results to quantify disease burden. The concept of an object-dependent disease map is introduced to express disease severity without performing explicit delineation and partial volume correction of either objects or lesions. The parameters of the disease map are estimated from a set of training image data sets. The idea is illustrated on 20 lung lesions and 20 liver lesions derived from 18F-2-fluoro-2-deoxy-D-glucose (FDG)-PET/CT scans of patients with various types of cancers and also on 20 NEMA PET/CT phantom data sets. Our preliminary results show that, on phantom data sets, "disease burden" can be estimated to within 2% of known absolute true activity. Notwithstanding the difficulty in establishing true quantification on patient PET images, our results achieve 8% deviation from "true" estimates, with slightly larger deviations for small and diffuse lesions where establishing ground truth becomes really questionable, and smaller deviations for larger lesions where ground truth set up becomes more reliable. We are currently exploring extensions of the approach to include fully automated body-wide DQ, extensions to just CT or magnetic resonance imaging (MRI) alone, to PET/CT performed with radiotracers other than FDG, and other functional forms of disease maps.

  6. Modern CT and PET/CT imaging of the liver; Moderne CT- und PET/CT-Bildgebung der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J.; Heusner, T.A.; Riegger, C.; Reichelt, D.; Kuhlemann, J.; Antoch, G.; Blondin, D. [Medizinische Fakultaet, Heinrich-Heine-Universitaet Duesseldorf, Institut fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2011-08-15

    Computed tomography (CT) is now widely available and represents an important and rapid method for the diagnostics of acute liver disease, characterization of focal liver lesions, planning of interventional therapy measures and postintervention control. In recent years CT has not become less important despite the increasing value of magnetic resonance imaging (MRI). By the use of different contrast medium phases good characterization of space-occupying lesions can be achieved. For the diagnostics of hepatocellular carcinoma (HCC) a triphasic examination protocol should always be implemented. The introduction of dual energy CT increased the sensitivity of imaging of hypervascularized and hypovascularized liver lesions and by the use of virtual native imaging it has become possible to avoid additional native imaging which reduces the x-ray exposition of patients. Positron emission tomography (PET) has an advantage for imaging in oncology because nearly the complete body of the patient can be screened and this is the main indication for PET/CT (whole-body staging). For purely hepatic problems 18F-fluorodeoxyglucose (FDG)-PET/CT using diagnostic CT data has a higher precision than CT alone but is inferior to MRI. (orig.) [German] Die Computertomographie (CT) ist heute breit verfuegbar und stellt eine wichtige und schnelle Methode zur Diagnostik akuter Lebererkrankungen, der Artdiagnostik fokaler Leberlaesionen und der Planung interventioneller Therapiemassnahmen sowie der postinterventionellen Kontrolle dar. In den letzten Jahren hat die CT trotz des zunehmenden Stellenwerts der Magnetresonanztomographie (MRT) nicht an Bedeutung verloren. Durch den Einsatz unterschiedlicher Kontrastmittelphasen kann meist eine gute Charakterisierung von Raumforderungen erfolgen. Bei der Diagnostik des hepatozellulaeren Karzinoms (HCC) sollte beispielsweise immer ein triphasisches Untersuchungsprotokoll angewendet werden. Mit Einfuehrung der Dual-energy-CT hat die Sensitivitaet in der

  7. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  8. Multi-institutional MicroCT image comparison of image-guided small animal irradiators

    Science.gov (United States)

    Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena

    2017-07-01

    To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2  >  0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR  >  36 and noise levels  1.5 lp mm-1 for MTF  =  0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set

  9. Centre for Industrial Application of CT scanning (CIA-CT) – Four years of results 2009-2013

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Andreasen, Jan Lasson; Christensen, Lars Bager;

    as a centre of excellence for industrial CT scanning, both nationally and internationally. A network with approx. 40 participants has been established, and a total of 22 students have been educated. Dissemination activities have encompassed: a web page www.cia-ct.mek.dtu.dk , 8 newsletters, 4 topical...

  10. Surface area and volume measurements of volcanic ash particles using micro-computed tomography (micro-CT): A comparison with scanning electron microscope (SEM) stereoscopic imaging and geometric considerations

    Science.gov (United States)

    Ersoy, Orkun; Şen, Erdal; Aydar, Erkan; Tatar, İlkan; Çelik, H. Hamdi

    2010-10-01

    Volcanic ash particles are important components of explosive eruptions, and their surface textures are the subject of intense research. Characterization of ash surfaces is crucial for understanding the physics of volcanic plumes, remote sensing measurements of ash and aerosols, interfacial processes, modelling transportation and deposition of tephra and characterizing eruptive styles. A number of different methods have been used over the years to arrive at surface area estimates. The more common methods include estimates based on geometric considerations (geometric surface area) and physisorption of gas molecules on the surface of interest (physical surface area). In this study, micro computed tomography (micro-CT), which is a non-destructive method providing three-dimensional data, enabled the measurement of surface area and volume of individual ash particles. Results were compared with the values obtained from SEM stereoscopic imaging and geometric considerations. Surface area estimates of micro-CT and SEM stereoscopic imaging are similar, with surface area/volume ratios (SA/V) of 0.0368 and 0.0467, respectively. Ash particle surface textures show a large deviation from that of simple geometric forms, and an approximation both to spheres and ellipsoids do not seem adequate for the representation of ash surface. SEM stereoscopic and/or micro-CT imaging are here suggested as good candidate techniques for the characterization of textures on macro-pore regions of ash particles.

  11. Does early ED CT scanning of afebrile patients with first episodes of acute pancreatitis ever change management?

    Science.gov (United States)

    Dachs, Robert J; Sullivan, Luke; Shanmugathasan, Preshanthini

    2015-06-01

    Rising utilization of computed tomography (CT) imaging early in the course of acute pancreatitis (AP) has been recently reported. However, radiographic demonstration of the degree of necrosis or the presence of complications is not fully apparent within the first days of an acute attack. The objective of this study was to examine if CT scanning early in the course of disease (<48 h of symptoms) in afebrile patients with an emergency department (ED) diagnosis of first episode of AP revealed any unanticipated pathology that altered clinical management. A retrospective chart review of all adult patients with a first episode of AP without fever admitted to the medical ward through the ED of our community hospital from January 1, 2011 to May 31, 2012 was performed. In cases in which CT scans were performed, the record was reviewed to determine if any unexpected findings were uncovered or if patient care was altered by the CT report. Two hundred forty-eight patients were admitted with an ED diagnosis of AP; 26.2 % (n = 65) met inclusion criteria; 70.8 % (n = 46) received a CT scan within 48 h of symptom onset. No patient that underwent CT scanning had an unexpected finding (95 % CI, 0.923-1.0). Our results demonstrate that afebrile patients with first episodes of AP do not benefit from early abdominal CT imaging. These results support the ACR Appropriateness Criteria recommendation that CT is not indicated in the first 48 h after symptom onset in unequivocal cases of AP.

  12. Evolving brain lesions in the follow-up CT scans 12 h after traumatic brain injury

    Institute of Scientific and Technical Information of China (English)

    Muhammad Sohail Umerani; Asad Abbas; Saqib Kamran Bakhshi; Ujala Muhammad Qasim; Salman Sharif

    2016-01-01

    Objective: To establish the frequency of evolution in CT appearance from an initial scan to a subsequent scan within 12 h and the prognostic significance of such deterioration. Methods: All patients who presented to Department of Neurosurgery, Liaquat National Hospital and Medical College with traumatic brain injury and received their CT scan within the first 4 h of injury were included in the study. Indications for repeat CT scan were: any deterioration in neurological status after the initial scan, potentially deterio-rating lesion on initial scan with or without worsening neurology, worsening neurological status after the initial CT scan findings, or no neurological improvement after initial management in patients with normal CT scan with significant head injury. This compiled with the data of 107 patients. Results: There were 67 males and 40 females. The cause of trauma of the 70%patients was road traffic accident. In 11 patients, the lesion evolved towards resorption while 32 patients had no significant changes in the subsequent CT scan. Sixty four patients showed an increase in the size of the lesion and 65.6%of them were required surgical intervention subsequently. Conclusions: In case where the initial CT scan performed within 4 h of significant head injury was not correlated with the patient's neurology, it should be repeated within 12 h.

  13. Improving CT scan capabilities with a new trauma workflow concept: Simulation of hospital logistics using different CT scanner scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Fung Kon Jin, P.H.P., E-mail: p.fungkonjin@amc.uva.nl [Trauma Unit Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Dijkgraaf, M.G.W., E-mail: m.dijkgraaf@amc.uva.nl [Department of Clinical Epidemiology, Biostatistics, and Bioinformatics, Academic Medical Center, Amsterdam (Netherlands); Alons, C.L., E-mail: clalons@few.vu.nl [Department of Mathematics, VU University Amsterdam, Amsterdam (Netherlands); Kuijk, C. van, E-mail: c.vankuijk@vumc.nl [Department of Radiology, VU Medical Center, Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.beenen@amc.uva.nl [Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Koole, G.M., E-mail: koole@few.vu.nl [Department of Mathematics, VU University Amsterdam, Amsterdam (Netherlands); Goslings, J.C., E-mail: j.c.goslings@amc.uva.nl [Trauma Unit Department of Surgery, Academic Medical Center, Amsterdam (Netherlands)

    2011-11-15

    Introduction: The Amsterdam Trauma Workflow (ATW) concept includes a sliding gantry CT scanner serving two mirrored (trauma) rooms. In this study, several predefined scenarios with a varying number of CT scanners and CT locations are analyzed to identify the best performing patient flow management strategy from an institutional perspective on process quality. Materials and methods: A total of six clinically relevant scenarios with variables that included the number of CT scanners, CT scanner location, and different patient categories (regular, urgent, and trauma patients) were evaluated using computer simulation. Each scenario was simulated using institutional data and was assessed for patient waiting times, idle time of CT scanners, and overtime due to scheduling. The best 2- and 3-scanner scenarios were additionally evaluated with the ATW-concept. Results: Based on institutional data, the best 2-scanner scenario distributes all 3 patient categories over both scanners and plans 4 urgent patients per hour while locating both scanners outside of the trauma room. The best 3-scanner scenario distributes urgent and regular patients over all 3 scanners and trauma patients on only 1 scanner and locates all CT scanners outside of the trauma room. The ATW concept reduces waiting times and overtime, while increasing idle time. Conclusion: Choosing the optimal planning and distribution strategies depends on the number and location of available CT scanners, along with number of trauma, urgent and regular patients. The Amsterdam Trauma Workflow concept could provide institutions with the ability of early CT scanning in trauma patients without influencing regular and urgent CT scanning.

  14. Total-body CT scanning in trauma patients: Benefits and boundaries

    NARCIS (Netherlands)

    Sierink, J.C.

    2015-01-01

    Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care. It is a fast and highly accurate modality for the identification of various injuries and it enables a rapid response to life-threatening problems. Especially total-body CT (TBCT) scanning is increasi

  15. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  16. Semi-automated method to measure pneumonia severity in mice through computed tomography (CT) scan analysis

    Science.gov (United States)

    Johri, Ansh; Schimel, Daniel; Noguchi, Audrey; Hsu, Lewis L.

    2010-03-01

    Imaging is a crucial clinical tool for diagnosis and assessment of pneumonia, but quantitative methods are lacking. Micro-computed tomography (micro CT), designed for lab animals, provides opportunities for non-invasive radiographic endpoints for pneumonia studies. HYPOTHESIS: In vivo micro CT scans of mice with early bacterial pneumonia can be scored quantitatively by semiautomated imaging methods, with good reproducibility and correlation with bacterial dose inoculated, pneumonia survival outcome, and radiologists' scores. METHODS: Healthy mice had intratracheal inoculation of E. coli bacteria (n=24) or saline control (n=11). In vivo micro CT scans were performed 24 hours later with microCAT II (Siemens). Two independent radiologists scored the extent of airspace abnormality, on a scale of 0 (normal) to 24 (completely abnormal). Using the Amira 5.2 software (Mercury Computer Systems), a histogram distribution of voxel counts between the Hounsfield range of -510 to 0 was created and analyzed, and a segmentation procedure was devised. RESULTS: A t-test was performed to determine whether there was a significant difference in the mean voxel value of each mouse in the three experimental groups: Saline Survivors, Pneumonia Survivors, and Pneumonia Non-survivors. It was found that the voxel count method was able to statistically tell apart the Saline Survivors from the Pneumonia Survivors, the Saline Survivors from the Pneumonia Non-survivors, but not the Pneumonia Survivors vs. Pneumonia Non-survivors. The segmentation method, however, was successfully able to distinguish the two Pneumonia groups. CONCLUSION: We have pilot-tested an evaluation of early pneumonia in mice using micro CT and a semi-automated method for lung segmentation and scoring system. Statistical analysis indicates that the system is reliable and merits further evaluation.

  17. Techniques in Iterative Proton CT Image Reconstruction

    CERN Document Server

    Penfold, Scott

    2015-01-01

    This is a review paper on some of the physics, modeling, and iterative algorithms in proton computed tomography (pCT) image reconstruction. The primary challenge in pCT image reconstruction lies in the degraded spatial resolution resulting from multiple Coulomb scattering within the imaged object. Analytical models such as the most likely path (MLP) have been proposed to predict the scattered trajectory from measurements of individual proton location and direction before and after the object. Iterative algorithms provide a flexible tool with which to incorporate these models into image reconstruction. The modeling leads to a large and sparse linear system of equations that can efficiently be solved by projection methods-based iterative algorithms. Such algorithms perform projections of the iterates onto the hyperlanes that are represented by the linear equations of the system. They perform these projections in possibly various algorithmic structures, such as block-iterative projections (BIP), string-averaging...

  18. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Yasuyuki; Murase, Kenya [Osaka Univ., Suita (Japan). Graduate School of Medicine; Higashino, Hiroshi [Ehime Prefectural Imabari Hospital (Japan); Mochizuki, Teruhito [Ehime Univ., Matsuyama (Japan). School of Medicine; Motomura, Nobutoku [Toshiba Corp., Otawara, Tochigi (Japan). Medical Engineering Lab.

    2002-09-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with {sup 201}Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external {gamma}-ray source ({sup 99m}Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  19. Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaowei; Servaes, Sabah; Darge, Kassa [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); University of Pennsylvania, The Perelman School of Medicine, Philadelphia, PA (United States); McCullough, William P. [University of Virginia Health System, Department of Radiology and Medical Imaging, Charlottesville, VA (United States); Mecca, Patricia [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2016-11-15

    Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens Flash {sup registered} CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDI{sub vol}) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality by

  20. Cervical CT scan-guided epidural blood patches for spontaneous intracranial hypotension.

    Science.gov (United States)

    Maingard, Julian; Giles, Lauren; Marriott, Mark; Phal, Pramit M

    2015-12-01

    We describe two patients with spontaneous intracranial hypotension (SIH), presenting with postural headache due to C1-C2 cerebrospinal fluid (CSF) leak. Both patients were refractory to lumbar epidural blood patching (EBP), and subsequently underwent successful CT scan-guided cervical EBP. SIH affects approximately 1 in 50,000 patients, with females more frequently affected. Its associated features are variable, and as such, misdiagnosis is common. Therefore, imaging plays an important role in the diagnostic workup of SIH and can include MRI of the brain and spine, CT myelogram, and radionuclide cisternography. In patients with an established diagnosis and confirmed CSF leak, symptoms will usually resolve with conservative management. However, in a select subgroup of patients, the symptoms are refractory to medical management and require more invasive therapies. In patients with cervical leaks, EBP in the cervical region is an effective management approach, either in close proximity to, or directly targeting a dural defect. CT scan-guided cervical EBP is an effective treatment approach in refractory SIH, and should be considered in those patients who are refractory to conservative management.

  1. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  2. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  3. The diagnostic value of PET/CT scanning in patients with cervical cancer

    DEFF Research Database (Denmark)

    Loft, Annika; Berthelsen, Anne Kiil; Roed, Henrik

    2007-01-01

    OBJECTIVE: To investigate the clinical value of PET/CT as a supplement to FIGO staging in patients with cervical cancer stage >or=1B. METHODS: This prospective study included 120 consecutive patients. After staging, a whole-body PET/CT scan was performed and these examinations were divided into two....../CT scanning for newly diagnosed cervical cancer FIGO stage >or=1B has a high sensitivity and specificity, and can be a valuable supplement to the FIGO staging procedure....

  4. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a good'' surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  5. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a ``good`` surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  6. Wide coverage by volume CT: benefits for cardiac imaging

    Science.gov (United States)

    Sablayrolles, Jean-Louis; Cesmeli, Erdogan; Mintandjian, Laura; Adda, Olivier; Dessalles-Martin, Diane

    2005-04-01

    With the development of new technologies, computed tomography (CT) is becoming a strong candidate for non-invasive imaging based tool for cardiac disease assessment. One of the challenges of cardiac CT is that a typical scan involves a breath hold period consisting of several heartbeats, about 20 sec with scanners having a longitudinal coverage of 2 cm, and causing the image quality (IQ) to be negatively impacted since beat to beat variation is high likely to occur without any medication, e.g. beta blockers. Because of this and the preference for shorter breath hold durations, a CT scanner with a wide coverage without the compromise in the spatial and temporal resolution of great clinical value. In this study, we aimed at determining the optimum scan duration and the delay relative to beginning of breath hold, to achieve high IQ. We acquired EKG data from 91 consecutive patients (77 M, 14 F; Age: 57 +/- 14) undergoing cardiac CT exams with contrast, performed on LightSpeed 16 and LightSpeed Pro16. As an IQ metric, we adopted the standard deviation of "beat-to-beat variation" (stdBBV) within a virtual scan period. Two radiologists evaluated images by assigning a score of 1 (worst) to 4 best). We validated stdBBV with the radiologist scores, which resulted in a population distribution of 9.5, 9.5, 31, and 50% for the score groups 1, 2, 3, and 4, respectively. Based on the scores, we defined a threshold for stdBBV and identified an optimum combination of virtual scan period and a delay. With the assumption that the relationship between the stdBBV and diagnosable scan IQ holds, our analysis suggested that the success rate can be improved to 100% with scan durations equal or less than 5 sec with a delay of 1 - 2 sec. We confirmed the suggested conclusion with LightSpeed VCT (GE Healthcare Technologies, Waukesha, WI), which has a wide longitudinal coverage, fine isotropic spatial resolution, and high temporal resolution, e.g. 40 mm coverage per rotation of 0.35 sec

  7. A longitudinal study of neurocysticercosis through CT scan of the brain

    Directory of Open Access Journals (Sweden)

    Abhiram Chakraborty

    2011-09-01

    Full Text Available Objective: To find out the role of CT scan in the diagnosis of neurocysticercosis (NC and also to get an idea of the nature and extent of this disease in a definite geographical ethnic location. Methods: CT scan of the brain of altogether 4 762 persons residing in a congested area of central Kolkata, was performed between 2004 and 2010, in an imaging centre in central Kolkata (Calcutta, of whom 1 114 (23.39% suspected patients were investigated for NC, having complaints of convulsion (472, headache (272, right sided weakness (98, loss of consciousness (84, left sided weakness (61, abnormal behavior (48, slurring of speech (34, difficulty with keeping balance (33 and dementia (12. Results: NC was detected in 45, 1, 0, 2, 1, 0, 0, 1 and 0, respectively consisting 4.48% (50/1 114 of the suspected cases varying from as low as 2 (in 2006 to as high as 23 (in 2005 in different years indicating this parasitic infection is perennial. The age of patients varied from 6 to 59 years of whom 28 (56% were vegan. We were also able to detect 4 types of lesions viz. calcified lesions (14, small hypodense i.e. vesicle (12, bright central spot i.e. vesicular lesion with central spot (2 and ring enhancement (22. For 3 patients, further imaging investigation (MRI was needed to confirm the diagnosis. We calculated the specificity and sensitivity of CT scan of brain diagnosing NC which was found to be 64% and 100%, respectively. Conclusions: Although, the sample may not be the representatives of the whole community, the findings suggest that cysticercosis is a significant but under-recognized public health concern in Kolkata.

  8. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lauzier, Pascal Theriault; Tang Jie; Speidel, Michael A.; Chen Guanghong [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States); Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States)

    2012-07-15

    Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution

  9. Value and clinical application of orthopedic metal artifact reduction algorithm in CT scans after orthopedic metal implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yi; Pan, Shinong; Zhao, Xudong; Guo, Wenli; He, Ming; Guo, Qiyong [Shengjing Hospital of China Medical University, Shenyang (China)

    2017-06-15

    To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants.

  10. Mirror-image lymph node in FDG PET/CT and SPECT/CT for sentinel node detection.

    Science.gov (United States)

    Domenech, Beatriz; Paredes, Pilar; Rubí, Sebastià; Pahisa, Jaume; Vidal-Sicart, Sergi; Pons, Francesca

    2014-03-01

    We report a case of a patient with presumed stage IB1 squamous cell carcinoma of the cervix in which FDG PET/CT scan revealed 1 hypermetabolic left iliac node suggestive to be malignant. Lymphoscintigraphy and SPECT/CT studies previous to sentinel node (SLN) biopsy revealed unilateral drainage in the right pelvis. Intraoperative pathological assessment of the SLN showed no tumoral involvement, and the hypermetabolic node revealed macrometastasis. Tumor node invasion can lead to a lymphatic blockage and become false-negative for SLN technique. Although FDG PET/CT has lower sensitivity than surgical staging, this case shows its value as a preoperative imaging technique.

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and accurate. A ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an ...

  12. Scanning Electron Microscopy Sample Preparation and Imaging.

    Science.gov (United States)

    Nguyen, Jenny Ngoc Tran; Harbison, Amanda M

    2017-01-01

    Scanning electron microscopes allow us to reach magnifications of 20-130,000× and resolve compositional and topographical images with intense detail. These images are created by bombarding a sample with electrons in a focused manner to generate a black and white image from the electrons that bounce off of the sample. The electrons are detected using positively charged detectors. Scanning electron microscopy permits three-dimensional imaging of desiccated specimens or wet cells and tissues by using variable pressure chambers. SEM ultrastructural analysis and intracellular imaging supplement light microscopy for molecular profiling of prokaryotes, plants, and mammals. This chapter demonstrates how to prepare and image samples that are (a) desiccated and conductive, (b) desiccated and nonconductive but coated with an electron conductive film using a gold sputter coater, and (c) wet and maintained in a hydrated state using a Deben Coolstage.

  13. CT perfusion imaging for patients of posterior circulation ischemia without responsible lesions on MRI scanning%MRI检查无责任病灶脑后循环缺血患者的CT灌注成像研究

    Institute of Scientific and Technical Information of China (English)

    戚观树; 侯群; 曹志坚; 李冉冉; 许茂盛

    2013-01-01

    Objective To assess the diagnostic value of CT perfusion imaging in patients of posterior circulation ischemia (PCI) without responsible lesions on MRI scanning. Methods Twenty four patients with clinical diagnosis of PCI underwent MRI DWI examination, for the patients without responsible lesions on MRI, CTPI was then performed. The region of interest (ROI ) was hand-painted and the perfusion parameters of abnormal regions and normal regions were recorded, including regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV),mean transmit time (MTT) and time to peak (TTP). Results Out of 24 cases positive CTPI was detected in 18 with a positive rate of 75%. There were 26 ischemic focuses detected, including 10 in cerebel um (38.5%), 7 in occipital lobe (26.9%), 3 in temporal lobe (11.5%) and 6 in brainstem (23.1%). Abnormal regions were detected on the diagram of TTP in 15 cases and the findings were corresponded to clinical symptoms;those were detected by rCBF in 13 cases and those detected by rCBC in 8 cases. The stages of cerebral infarction prophase included I-1 in 4 cases, I-2 in 1 case, II-1 in 5 cased and II-2 in 8 cases. Conclusion CTPI can objectively evaluate cerebral blood flow perfusion and is of value in detection of ischemic focuses that are not found by MRI scanning.%  目的探讨MRI检查显示无责任病灶的脑后循环缺血(PCI)患者的局部脑血流灌注情况,探索PCI患者早期诊断的有效方法.方法选取符合PCI临床诊断的24例患者行头颅MRI检查,对未发现责任病灶的患者进一步行CT灌注成像(CTPI)检查.在CTPI图像上手绘感兴趣区域(ROI),记录病灶区与对照区的灌注参数,包括局部脑血流量(rCBF)、局部脑血容量(rCBV)、平均通过时间(MTT)和达峰时间(TTP).结果 CTPI检查发现异常灌注18例(阳性率75%),缺血灶共26处,其中小脑10处(38.5%),枕叶7处(26.9%),颞叶3处(11.5%),脑干6处(23.1%).TTP发现异常15例,且均与临床

  14. Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rebiere, Marilou, E-mail: Marilou.Rebiere@rwth-aachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Verburg, Frederik A., E-mail: fverburg@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Experimental Molecular Imaging, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Krohn, Thomas, E-mail: tkrohn@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Pietsch, Hubertus, E-mail: hubertus.pietsch@bayer.com [Contrast Media Research, Bayer Pharma AG, Muellerstr. 178, 13353 Berlin (Germany); Kuhl, Christiane K., E-mail: ckuhl@ukaachen.de [Department of Radiology, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Mottaghy, Felix M., E-mail: fmottaghy@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany); Department of Nuclear Medicine, Maastricht University Medical Center, P. Debeylaan 25, 6202 AZ Maastricht (Netherlands); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, University Hospital RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen (Germany)

    2012-08-15

    Purpose: To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. Material and methods: 140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and venous contrast enhanced CT. The first (second) 70 patients, received contrast medium with 370 (300) mg iodine/ml. The iodine delivery rate (1.3 mg/s) and total iodine load (44.4 g) were identical for both groups. Contrast enhancement and maximum and mean standardized FDG uptake values (SUVmax and SUVmean) were determined for the un-enhanced, arterial and venous PET/CT at multiple anatomic sites and PET reconstructions were visually evaluated. Results: Arterial contrast enhancement was significantly higher for the 300 mg/ml contrast medium compared to 370 mg I/ml at all anatomic sites. Venous enhancement was not different between the two contrast media. SUVmean and SUVmax were significantly higher for the contrast enhanced compared to the non-enhanced PET/CT at all anatomic sites (all P < 0.001). Tracer uptake was significantly higher in the arterial than in the venous PET/CT in the arteries using both contrast media (all P < 0.001). No differences in tracer uptake were found between the contrast media (all P > 0.05). Visual assessment revealed no relevant differences between the different PET reconstructions. Conclusions: There is no relevant qualitative influence on the PET scan from the use of different intravenous contrast media in its various phases in combined multiphase PET/CT. For quantitative analysis of tracer uptake it is required to use an identical PET/CT protocol.

  15. Construction and analysis of a head CT-scan database for craniofacial reconstruction.

    Science.gov (United States)

    Tilotta, Françoise; Richard, Frédéric; Glaunès, Joan; Berar, Maxime; Gey, Servane; Verdeille, Stéphane; Rozenholc, Yves; Gaudy, J F

    2009-10-30

    This paper is devoted to the construction of a complete database which is intended to improve the implementation and the evaluation of automated facial reconstruction. This growing database is currently composed of 85 head CT-scans of healthy European subjects aged 20-65 years old. It also includes the triangulated surfaces of the face and the skull of each subject. These surfaces are extracted from CT-scans using an original combination of image-processing techniques which are presented in the paper. Besides, a set of 39 referenced anatomical skull landmarks were located manually on each scan. Using the geometrical information provided by triangulated surfaces, we compute facial soft-tissue depths at each known landmark positions. We report the average thickness values at each landmark and compare our measures to those of the traditional charts of [J. Rhine, C.E. Moore, Facial Tissue Thickness of American Caucasoïds, Maxwell Museum of Anthropology, Albuquerque, New Mexico, 1982] and of several recent in vivo studies [M.H. Manhein, G.A. Listi, R.E. Barsley, et al., In vivo facial tissue depth measurements for children and adults, Journal of Forensic Sciences 45 (1) (2000) 48-60; S. De Greef, P. Claes, D. Vandermeulen, et al., Large-scale in vivo Caucasian facial soft tissue thickness database for craniofacial reconstruction, Forensic Science International 159S (2006) S126-S146; R. Helmer, Schödelidentifizierung durch elektronische bildmischung, Kriminalistik Verlag GmbH, Heidelberg, 1984].

  16. CT scanning carcases has no detrimental effect on the colour stability of M. longissimus dorsi from beef and sheep.

    Science.gov (United States)

    Jose, C G; Pethick, D W; Jacob, R H; Gardner, G E

    2009-01-01

    This study investigated the effect of computerised tomography imaging (CT scan), for carcase composition determination, on the oxy/metmyoglobin ratio, hue and L(∗), a(∗) and b(∗) scores of M. longissimus dorsi from both beef and lamb. Beef and lamb M. longissimus dorsi were divided into four proportions and randomly allocated to one of the following treatments; CT 30 day aged; CT fresh; control 30 day aged; control fresh. Colour measurements were made over a 96h retail display period. CT scan had little effect on the colour of both lamb and beef across all colour parameters. There was a small negative affect observed in CT aged samples (PCT. Aged M. longissimus dorsi clearly had a worse colour stability than the fresh packaged samples, while beef was a lot more colour stable than lamb. It appears that CT scan for the purpose of body composition determination will not have any commercially relevant impact on colour stability of both beef and lamb.

  17. Effective doses associated with PET-CT scans two common in pediatric patients; Dosis efectivas asociadas a dos exploraciones PET-CT habituales en pacientes pediatricos

    Energy Technology Data Exchange (ETDEWEB)

    Camacho Lopez, C.; Garcia Martinez, M. t.; Marti Vidal, J. f.; Falgas Lacuela, M.; Vercher Conejero, J. L.

    2011-07-01

    The main objective of this paper is to outline the effective dose (E) that can be given in two studies conducted PET-CT common for children, in the absence of standard protocols both at standardizing the way image acquisition in this field, as standard levels to guide us when it comes to associate a certain effective dose to pediatric PET-CT scan. These doses will be compared to an adult patient receiving the same type of examination, and consider the percentage of the total dose due to TC.

  18. Study of optimize scanning program of double helical CT in reducing skull base artifacts in images%优化扫描方案减轻双排螺旋CT颅底伪影的研究

    Institute of Scientific and Technical Information of China (English)

    何新华; 胡永胜; 杨越; 胡鹏程; 王自勇; 付璇; 慕鹏

    2014-01-01

    目的:优化扫描方案,减少颅底伪影,改善图像质量。方法双排螺旋CT头颅平扫病例60例,随机分为3组,每组20例。 A、B组采用常规序列扫描,A组层厚为8 mm (4.0 mm ×2),B组层厚为4 mm(4.0 mm ×2)。 C组采用2段螺旋扫描程序,扫描参数为颅底3 mm (1.5 mm ×2)+颅脑幕上5 mm(2.5 mm ×2)。观察和评价后、中颅窝图像有无伪影、伪影形态、位置、严重程度等。结果除A组1例外,A、B两组后颅窝均有不同程度的放射状伪影和交叉伪影,中颅窝部分病例有不同程度伪影。 B组Ⅱ级伪影的总数多于A组(29/16),Ш级伪影2例,显示B组4 mm层厚不能减轻颅底伪影,且有加重伪影程度的可能。 C组中部分病例后颅窝、中颅窝未见明显伪影,Ⅱ级伪影的例数为5例。与A、B组比较, C组可显著减轻颅底伪影,差异有统计学意义(P<0.05)。结论颅底3 mm (1.5 mm ×2)+颅脑幕上5 mm(2.5 mm ×2)螺旋扫描法,可显著减轻颅底伪影,改善图像质量,清晰显示颅底组织结构,具有临床应用价值。%Objective To optimize the scanning programs in order to reduce the skull base artifacts and improve images quality . Methods Sixty cases of brain performed with double helical CT were randomly divided into three groups with 20 in each.Group A and B u-sing routine sequential program ,the thickness was 8mm (4.0 mm ×2) in group A and was 4mm (4.0 mm ×2) in group B.Group C using two segments helical scan,the thickness for the base of the skull (Base) was 3mm (1.5 mm ×2),and for cerebrum (above brain curtain) was 5 mm (2.5 mm ×2).The artifacts shape,location,severity at posterior fossa,and middle cranial fossa images were observed and evalua-ted.Results In group A and B ,almost all cases had varying severity of radial and cross artifacts at posterior fossa ,and had different degrees of artifacts at middle cranial fossa in

  19. Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Hun; Park, Jin Hong; Choi, Byung Don; Won, Hui Su; Chang, Nam Jun; Goo, Jang Hyun; Hong, Joo Wan [Dept. of Radiation Oncology, Seoul national university bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, 15x15cm{sup 2} and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

  20. The value of baseline CT head scans in the assessment of shunt complications in hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, P. (Alder Hey Children' s Hospital, Liverpool (United Kingdom)); Fraser, F. (Alder Hey Children' s Hospital, Liverpool (United Kingdom)); Pilling, D. (Alder Hey Children' s Hospital, Liverpool (United Kingdom)); Carty, H. (Alder Hey Children' s Hospital, Liverpool (United Kingdom))

    1993-10-01

    The purpose of this study was to determine the value of a baseline CT head scan in the assessment of patients who subsequently presented with symptoms which may have been due to shunt complications (such as blockage or infection). In all these patients the shunt had been inserted in the treatment of hydrocephalus. We conclude that the presence of a baseline scan does not add to the interpretation of CT scans done when the patient presents with symptoms of possible shunt malfunction. (orig.)

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  2. Surface area and volume measurements of volcanic ash particles using micro-computed tomography (micro-CT): A comparison with scanning electron microscope (SEM) stereoscopic imaging and Brunauer-Emmett-Teller (BET) model

    Science.gov (United States)

    Ersoy, Orkun; Şen, Erdal; Aydar, Erkan; Tatar, Ä.°Lkan; Ćelik, H. Hamdi

    2010-05-01

    Volcanic ash particles are important components of explosive eruptions and their surface texture is the subject of intense research. Characterization of ash surfaces is crucial for understanding the physics of the volcanic plumes, remote sensing measurements of ash and aerosols, interfacial processes, modelling transportation and deposition of tephra and characterizing eruptive styles. A number of different methods have been used over the years to arrive at surface area estimates. The more common methods include estimates based on the geometric considerations (geometric surface area) and the physisorption of gas molecules on the surface of interest (physical surface area). In this study, micro computed tomography (micro-CT), a non-destructive method providing three-dimensional data enabled the measurement of surface areas and volumes of individual ash particles. Specific surface area estimates for ash particles were also obtained using nitrogen as gas adsorbent and the BET (Brunauer-Emmett-Teller) model. Results were compared with the values obtained from SEM stereoscopic imaging and geometric considerations. Surface area estimates of micro-CT and SEM stereoscopic imaging overlaps with mean specific surface area results of 0.0167 and 0.0214 m2/g, respectively. However, ash particle surface textures present quite a deviation from that of their geometric forms and approximation to sphere and ellipsoid both seemed to be inadequate for representation of real ash surfaces. The higher surface area estimate (> 0.4 m2/g) obtained from the technique based on physical sorption of gases (BET model here) was attributed to its capability for surface areas associated even with angstrom-sized pores. SEM stereoscopic and/or micro-CT imaging were suggested for characterization of textures on macro-pore regions of ash particles.

  3. Course and variation of the intercostal artery by CT scan.

    Science.gov (United States)

    Helm, Emma J; Rahman, Najib M; Talakoub, Omid; Fox, Danial L; Gleeson, Fergus V

    2013-03-01

    It is conventionally taught that the intercostal artery is shielded in the intercostal groove of the superior rib. The continuous course and variability of the intercostal artery, and factors that may influence them, have not been described in a large number of arteries in vivo. Maximal intensity projection reformats in the coronal plane were produced from CT scan pulmonary angiograms to identify the posterolateral course of the intercostal artery (seventh to 11th rib spaces). A novel semiautomated computer segmentation algorithm was used to measure distances between the lower border of the superior rib, the upper border of the inferior rib, and the position of the intercostal artery when exposed in the intercostal space. The position and variability of the artery were analyzed for association with clinical factors. Two hundred ninety-eight arteries from 47 patients were analyzed. The mean lateral distance from the spine over which the artery was exposed within the intercostal space was 39 mm, with wide variability (SD, 10 mm; 10th-90th centile, 28-51 mm). At 3 cm lateral distance from the spine, 17% of arteries were shielded by the superior rib, compared with 97% at 6 cm. Exposed artery length was not associated with age, sex, rib space, or side. The variability of arterial position was significantly associated with age (coefficient, 0.91; P intercostal artery is exposed within the intercostal space in the first 6 cm lateral to the spine. The variability of its vertical position is greater in older patients and in more cephalad rib spaces.

  4. A comparative study of the diagnostic accuracy on Waters view with CT scan in detecting midface fractures

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2006-08-01

    Full Text Available Background and Aim: In recent years, CT scan has become available as an alternative to conventional radiography. To date, the utility of Waters view in detecting midface fractures has been rarely evaluated. The aim of this study was to compare the diagnostic accuracy and reliability of Waters radiography with CT scan in detecting midface fractures. Materials and Methods: In this tests evaluation study, waters view and CT scan were performed for 42 patients with midface fracture admitted to maxillofacial surgery department of Shariati hospital. All images were observed and interpreted by an oral and maxillofacial radiologist and an oral and maxillofacial surgeon. Sensitivity, specificity and reliability for Waters view in detecting midface fractures were assessed by Cohen’s kappa test. Results: Sensitivity and specificity for Waters view in detection of midface fratures by the radiologist were 31.79% and 95.35% and by the surgeon were 29.59% and 93.75% respectively. The highest reliability in CT scan and Waters view (in nasal fractures by the radiologist was 66.67% and was 58.33% by the surgeon in buttress of zygoma. The highest agreement rate between the radiologist and the surgeon for CT scan was in zygomatic arch (78.95% and for Waters view was in nasal fracture (62.5%. Conclusion: Based on the results of this study, the specificity of Waters view is sufficient to diagnose fractures of lateral orbital wall, infraorbital rim, orbital floor, zygomatic arch, frontozygomatic suture, lateral wall of maxillary sinus and Lefort II fracture. The specificity is not sufficient to diagnose fractures of medial orbital wall and anterior, posterior and medial wall of maxillary sinus. Detection of these midface fractures needs other conventional radiographies or CT scan.

  5. Denoising CT Images using wavelet transform

    Directory of Open Access Journals (Sweden)

    Lubna Gabralla

    2015-05-01

    Full Text Available Image denoising is one of the most significant tasks especially in medical image processing, where the original images are of poor quality due the noises and artifacts introduces by the acquisition systems. In this paper, we propose a new image denoising scheme by modifying the wavelet coefficients using soft-thresholding method, we present a comparative study of different wavelet denoising techniques for CT images and we discuss the obtained results. The denoising process rejects noise by thresholding in the wavelet domain. The performance is evaluated using Peak Signal-to-Noise Ratio (PSNR and Mean Squared Error (MSE. Finally, Gaussian filter provides better PSNR and lower MSE values. Hence, we conclude that this filter is an efficient one for preprocessing medical images.

  6. Data compression of scanned halftone images

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Jensen, Kim S.

    1994-01-01

    A new method for coding scanned halftone images is proposed. It is information-lossy, but still preserving the image quality, compression rates of 16-35 have been achieved for a typical test image scanned on a high resolution scanner. The bi-level halftone images are filtered, in phase...... with the halftone grid, and converted to a gray level representation. A new digital description of (halftone) grids has been developed for this purpose. The gray level values are coded according to a scheme based on states derived from a segmentation of gray values. To enable real-time processing of high resolution...... scanner output, the coding has been parallelized and implemented on a transputer system. For comparison, the test image was coded using existing (lossless) methods giving compression rates of 2-7. The best of these, a combination of predictive and binary arithmetic coding was modified and optimized...

  7. Heart region segmentation from low-dose CT scans: an anatomy based approach

    Science.gov (United States)

    Reeves, Anthony P.; Biancardi, Alberto M.; Yankelevitz, David F.; Cham, Matthew D.; Henschke, Claudia I.

    2012-02-01

    Cardiovascular disease is a leading cause of death in developed countries. The concurrent detection of heart diseases during low-dose whole-lung CT scans (LDCT), typically performed as part of a screening protocol, hinges on the accurate quantification of coronary calcification. The creation of fully automated methods is ideal as complete manual evaluation is imprecise, operator dependent, time consuming and thus costly. The technical challenges posed by LDCT scans in this context are mainly twofold. First, there is a high level image noise arising from the low radiation dose technique. Additionally, there is a variable amount of cardiac motion blurring due to the lack of electrocardiographic gating and the fact that heart rates differ between human subjects. As a consequence, the reliable segmentation of the heart, the first stage toward the implementation of morphologic heart abnormality detection, is also quite challenging. An automated computer method based on a sequential labeling of major organs and determination of anatomical landmarks has been evaluated on a public database of LDCT images. The novel algorithm builds from a robust segmentation of the bones and airways and embodies a stepwise refinement starting at the top of the lungs where image noise is at its lowest and where the carina provides a good calibration landmark. The segmentation is completed at the inferior wall of the heart where extensive image noise is accommodated. This method is based on the geometry of human anatomy and does not involve training through manual markings. Using visual inspection by an expert reader as a gold standard, the algorithm achieved successful heart and major vessel segmentation in 42 of 45 low-dose CT images. In the 3 remaining cases, the cardiac base was over segmented due to incorrect hemidiaphragm localization.

  8. An evaluation on CT image acquisition method for medical VR applications

    Science.gov (United States)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  9. Clinical significance of multislice spiral CT scans in hepatic veins occlusion in Budd-Chiari syndrome

    Institute of Scientific and Technical Information of China (English)

    MENG Xiao-chun; ZHU Kang-shun; QIN Jie; ZHANG Jian-sheng; WANG Xiao-hong; ZOU Yan; ZHANG Ya-qin; SHAN Hong

    2007-01-01

    Background Budd-Chiari syndrome with hepatic vein occlusion (HVBCS) can induce severe portal hypertension and liver damage. We retrospectively analyzed hepatic CT features of HVBCS and evaluated the usefulness of triphasic enhancement of CT examinations and CT angiography (CTA) in its diagnosis.Methods Twenty-five cases with HVBCS, confirmed by digital subtraction angiography (DSA), received a triphasic enhancement CT scan within one week before DSA. The CTA images of the relevant blood vessels were reconstructed with maximum intensity projection, volume rendering and oblique reformat techniques.Results Compared with DSA, the detection rate of transverse CT and CTA images for abnormal hepatic vein were 81.7% (58/71) and 95.8% (68/71) (χ2=7.044, P=0.008), for membranous obstruction were 47.4% (9/19) and 84.2% (16/19) respectively (χ2 =5.729, P=0.017 ), for segmental obstruction were 88.0% (22/25) and 100% (25/25) respectively (χ2=1.418, P=0.234). The detection rates for hepatic vein stenosis were 100% with each method. Diffuse hepatomegaly was found in all 6 cases in acute phase and 3 of 19 cases in chronic phase who had severe obstruction of three hepatic veins without patent intrahepatic collaterals. The other 16 cases in chronic phase had hepatatrophia to different extents related to the obstructed hepatic vein. All in acute phase and 15 in chronic phase presented typical patchy enhancement initially in caudate lobe and perihilar areas and enlarged with time delay. In all cases, parenchyma areas with atrophy, necrosis and congestion demonstrated lower and later enhancement. In all the parts, which had normal enhancement at least one patent outflow hepatic vein, accessory hepatic vein or collateral vessel was detected. Conclusion Dynamic enhancement CT examination by multislice spiral CT not only could improve the diagnosis of HVBCS by CTA technique, but also could noninvasively provide anatomical information and reveal damage to the hepatic parenchyma.

  10. CT scan-based modelling of anastomotic leak risk after colorectal surgery.

    Science.gov (United States)

    Gervaz, P; Platon, A; Buchs, N C; Rocher, T; Perneger, T; Poletti, P-A

    2013-01-01

    Prolonged ileus, low-grade fever and abdominal discomfort are common during the first week after colonic resection. Undiagnosed anastomotic leak carries a poor outcome and computed tomography (CT) scan is the best imaging tool for assessing postoperative abdominal complications. We used a CT scan-based model to quantify the risk of anastomotic leak after colorectal surgery. A case-control analysis of 74 patients who underwent clinico-radiological evaluation after colorectal surgery for suspicion of anastomotic leak was undertaken and a multivariable analysis of risk factors for leak was performed. A logistic regression model was used to identify determinant variables and construct a predictive score. Out of 74 patients with a clinical suspicion of anastomotic leak, 17 (23%) had this complication confirmed following repeat laparotomy. In multivariate analysis, three variables were associated with anastomotic leak: (1) white blood cells count > 9 × 10(9) /l (OR = 14.8); (2) presence of ≥ 500 cm(3) of intra- abdominal fluid (OR = 13.4); and (3) pneumoperitoneum at the site of anastomosis (OR = 9.9). Each of these three parameters contributed one point to the risk score. The observed risk of leak was 0, 6, 31 and 100%, respectively, for patients with scores of 0, 1, 2 and 3. The area under the receiver operating characteristic curve for the score was 0.83 (0.72-0.94). This CT scan-based model seems clinically promising for objective quantification of the risk of a leak after colorectal surgery. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  11. Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    OpenAIRE

    Dimitrios Lyras; Craig Loucks; Robert Greenhow

    2016-01-01

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard protocol. Using this database, the Hip-Knee-Angle (HKA), the Femur Valgus Angle (FVA), the Tibia Varus A...

  12. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; von Schulthess, Gustav K.; Buck, Alfred [Division of Nuclear Medicine, Department of Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    Germanium-68 based attenuation correction (PET{sub Ge68}) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET{sub CT}) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET{sub Ge68} and PET{sub CT}. Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET{sub CT} in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET{sub Ge68} images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET{sub Ge68} and PET{sub CT} images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional {sup 68}Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the

  13. Radiation dose and imaging quality of abdominal computed tomography before and scan protocol adjustment: Single-institution experience in three years

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hwi Young; Choi, Joon Il; Jung, Seung Eun; Rha, Seong Eun; Oh, Nam Soon; Lee, Young Joon; Byun, Jae Young [Dept. of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    To compare radiation dose and image quality of abdominal CT for patients who underwent repeated CT examinations before and after adjustment of scan protocol. We compared radiation dose and image quality of repeated abdominal CT scans (at three-year-interval) of 50 patients with chronic liver disease, 50 patients with early gastric cancer, and 50 patients with uterine cancer. To reduce radiation dose, we optimized CT protocols by omitting unnecessary pre-contrast phase, reducing kVp, and setting higher noise index. Data of dose reports were collected. Objective image quality was evaluated for noise level, signal to noise ratio (SNR), and contrast noise ratio (CNR). For subjective image quality, we evaluated image noise, contrast, and overall diagnostic acceptability. The mean values of dose length product of 2011 CT scans compared to those of 2008 CT scans were 27.6% to 45.7%. The image noise level, SNR, and CNR were significantly (p < 0.05) worse in 2011 CT scans compared to 2008 CT scans. For subjective image quality, image noise was also significantly (p < 0.05) worse in 2011. However, CNR and diagnostic acceptability showed variable results. No CT scans were considered as unacceptable image.We modified abdominal CT protocols to reduce radiation exposure while trying to maintain diagnostic acceptability.

  14. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  15. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author).

  16. Mobile CT. Technical aspects of prehospital stroke imaging before intravenous thrombolysis; CT im Notarztwagen. Technische Aspekte der praehospitalen radiologischen Schlaganfalldiagnostik vor systemischer Thrombolyse

    Energy Technology Data Exchange (ETDEWEB)

    Gierhake, Daniel; Villringer, K.; Fiebach, J.B. [Charite - Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Weber, J.E.; Audebert, H.J. [Charite - Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite - Universitaetsmedizin Berlin (Germany). Klinik fuer Neurologie; Ebinger, M. [Charite - Universitaetsmedizin Berlin (Germany). Center for Stroke Research Berlin (CSB); Charite - Universitaetsmedizin Berlin (Germany). Klinik und Hochschulambulanz fuer Neurologie

    2013-01-15

    To reduce the time from symptom onset to treatment with tissue plasminogen activator (tPA) in ischemic stroke, an ambulance was equipped with a CT scanner. We analyzed process and image quality of CT scanning during the pilot study regarding image quality and safety issues. The pilot study of a stroke emergency mobile unit (STEMO) ran over a period of 12 weeks on 5 weekdays from 7a. m. to 6:30 p. m. A teleradiological service for the justifying indication and reporting was established. The radiographer was responsible for the performance of the CT scan on the ambulance. 64 cranial CT scans and 1 intracranial CT angiography were performed. We compared times from ambulance alarm to treatment decision (time of last brain scan) with a cohort of 50 consecutive tPA treatments before implementation of STEMO. 62 (95 %) of the 65 scans performed had sufficient quality for reading. Technical quality was not optimal in 45 cases (69 %) mainly caused by suboptimal positioning of patient or eye lense protection. Motion artefacts were observed in 8 exams (12 %). No safety issues occurred for team or patients. 23 patients were treated with thrombolysis. Time from alarm to last CT scan was 18 minutes shorter than in the tPA cohort before STEMO implementation. A teleradiological support for primary stroke imaging by CT on-site is feasible, quality-wise of diagnostic value and has not raised safety issues. (orig.)

  17. Is It Possible to Predict Heart Rate and Range during Enhanced Cardiac CT Scan from Previous Non-enhanced Cardiac CT?

    OpenAIRE

    Horiguchi, Jun; Yamamoto, Hideya; Arie, Ryuichi; Kiguchi, Masao; Fujioka, Chikako; Ohtaki, Megu; Kihara, Yasuki; Awai, Kazuo

    2010-01-01

    The effect of heart rate and variation during cardiac computed tomography (CT) on the examination quality. The purpose of this study is to investigate whether it is possible to predict heart rate and range during enhanced cardiac computed CT scan from previous non-enhanced cardiac CT scan. Electrocardiograph (ECG) files from 112 patients on three types of cardiac 64-slice CT (non-enhanced, prospective ECG-triggered and retrospective ECG-gated enhanced scans) were recorded. The mean heart rate...

  18. Brain tumors and CT scan in infants and children, (1). The impact on pediatric neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Ohi, S.; Velasco, J.M. (Northwestern Univ., Chicago, IL (USA). Medical School)

    1980-10-01

    The dramatic change in the neuroradiological procedures have been noted after CT scan was introduced in the last several years. Remarkable decreasing numbers of angiographic, pneumoencephalographic and other invasive neuroradiologic studies as well as nuclear brain scan were also found in the pediatric neuroradiology. The authors analyzed the total numbers of these studies performed in the last several years in pediatric neurological/neurosurgical practice in the light of the impact of CT scan especially in the diagnostic procedures and treatments of brain tumor in children. Although the number of these procedures decreased up to 49% in plain skull X-ray, 54% in cerebral angiography, 70% in pneumoencephalography/ventriculography and 79% in nuclear brain scan after CT scan was installed in our results, it is extremely important to renew understanding of those characteristics in each special procedures. Cerebral angiography as well as pneumoencephalography may give the surgeon more precise ideas of the anatomical relationship between the lesion and other normal structures, especially in the posterior fossa tumor in which CT scan occassionally demonstrates only a gross finding. A case with false negative result and another case with a complicated anatomical structure in CT scan were presented. The significance of cerebral angiography and other invasive studies in the diagnosis and follow up of brain tumor in CT scan were discussed.

  19. The influence of respiratory motion on CT image volume definition

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Romero, Ruth, E-mail: rrromero@salud.madrid.org; Castro-Tejero, Pablo, E-mail: pablo.castro@salud.madrid.org [Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Puerta de Hierro Majadahonda, 28222 Madrid (Spain)

    2014-04-15

    Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath

  20. The influence of respiratory motion on CT image volume definition.

    Science.gov (United States)

    Rodríguez-Romero, Ruth; Castro-Tejero, Pablo

    2014-04-01

    Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. 4DCT acquisitions provided volume and position accuracies within ± 3% and ± 2 mm for structure dimensions >2 cm, breath amplitude ≤ 15 mm, and breath period ≥ 3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher

  1. Clinical micro-CT for dental imaging

    Science.gov (United States)

    Youn, Hanbean; Cho, Min Kook; Shon, Cheol-Soon; Cho, Bong Hae; Kim, Chang Hyuk; Kim, Ho Kyung

    2009-02-01

    We exploit the development of a clinical computed microtomography (micro-CT) system for dental imaging. While the conventional dental CT simply serves implant treatment, the clinical dental micro-CT may provide clinicians with a histologic evaluation. To investigate the feasibility of the realization of a dental micro-CT, we have constructed an experimental test system which mainly consists of a microfocus x-ray source, a rotational subject holder, and a flat-panel detector. The flat-panel detector is based on a matrix-addressed photodiode array coupled to a CsI:Tl scintillator. The detective quantum efficiency (DQE) of the detector was measured as a function of magnification based on the measured modulation-transfer function (MTF) and noise-power spectrum (NPS). The best MTF and DQE performances were achieved at the magnification factor of 3. Similar tendency of the spatial resolving power in tomography was also observed with a wire phantom having a 25 μm diameter. From the investigation of tomographs reconstructed from a humanoid skull phantom, the application of magnification in the system largely reduced both signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for a fixed dose at the entrance surface of the detector, 1.2 mGy, while this setup increased the dose at the object plane from 4.7 mGy to 19.1 mGy for the magnification factor from 2 to 4, respectively. Although the quantum mottles at the high magnification factor tackled the practical use in the clinic, the information contained in the magnified CT images was quite promising.

  2. Fully automatic segmentation of femurs with medullary canal definition in high and in low resolution CT scans.

    Science.gov (United States)

    Almeida, Diogo F; Ruben, Rui B; Folgado, João; Fernandes, Paulo R; Audenaert, Emmanuel; Verhegghe, Benedict; De Beule, Matthieu

    2016-12-01

    Femur segmentation can be an important tool in orthopedic surgical planning. However, in order to overcome the need of an experienced user with extensive knowledge on the techniques, segmentation should be fully automatic. In this paper a new fully automatic femur segmentation method for CT images is presented. This method is also able to define automatically the medullary canal and performs well even in low resolution CT scans. Fully automatic femoral segmentation was performed adapting a template mesh of the femoral volume to medical images. In order to achieve this, an adaptation of the active shape model (ASM) technique based on the statistical shape model (SSM) and local appearance model (LAM) of the femur with a novel initialization method was used, to drive the template mesh deformation in order to fit the in-image femoral shape in a time effective approach. With the proposed method a 98% convergence rate was achieved. For high resolution CT images group the average error is less than 1mm. For the low resolution image group the results are also accurate and the average error is less than 1.5mm. The proposed segmentation pipeline is accurate, robust and completely user free. The method is robust to patient orientation, image artifacts and poorly defined edges. The results excelled even in CT images with a significant slice thickness, i.e., above 5mm. Medullary canal segmentation increases the geometric information that can be used in orthopedic surgical planning or in finite element analysis.

  3. Three-dimensional helical CT imaging of bone and joint diseases in the trunk and the hip joints. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Gong Hohghan [Jangxi Medical Coll. (China). First Affiliated Hospital; Hiraishi, Kumiko; Doi, Miwako; Matsui, Ritsuo; Simizu, Tadafumi; Sueyoshi, Kouzou; Narabayashi, Isamu

    1997-12-01

    To confirm the utility of CT scan images for orthopedic surgeons managing patients with complex disorders, we have produced and studied three-dimensional images from helical CT scans of 28 patients with various bone and joint disorders in the trunk and the hip joint. The CT scanner employed was a Toshiba X-force, and the 3D-CT images were constructed on an X-link50. The 3D images obtained could be observed from various projections. Congenital vertebral malformations, spondylosis, OPLL, osteonecrosis, fractures, and bone tumors were examined, and the 3D helical CT images brought useful information to bear on the spatial location and extent of the lesions. Therefore, 3D helical CT should become an indispensable tool for both preoperative examination and post-operative follow-up studies in orthopedic surgery. (author)

  4. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  5. Comparison of stroke infarction between CT perfusion and diffusion weighted imaging: preliminary results

    Science.gov (United States)

    Abd. Rahni, Ashrani Aizzuddin; Arka, Israna Hossain; Chellappan, Kalaivani; Mukari, Shahizon Azura; Law, Zhe Kang; Sahathevan, Ramesh

    2016-03-01

    In this paper we present preliminary results of comparison of automatic segmentations of the infarct core, between that obtained from CT perfusion (based on time to peak parameter) and diffusion weighted imaging (DWI). For each patient, the two imaging volumes were automatically co-registered to a common frame of reference based on an acquired CT angiography image. The accuracy of image registration is measured by the overlap of the segmented brain from both images (CT perfusion and DWI), measured within their common field of view. Due to the limitations of the study, DWI was acquired as a follow up scan up to a week after initial CT based imaging. However, we found significant overlap of the segmented brain (Jaccard indices of approximately 0.8) and the percentage of infarcted brain tissue from the two modalities were still fairly highly correlated (correlation coefficient of approximately 0.9). The results are promising with more data needed in future for clinical inference.

  6. Seamless stitching of tile scan microscope images.

    Science.gov (United States)

    Legesse, F B; Chernavskaia, O; Heuke, S; Bocklitz, T; Meyer, T; Popp, J; Heintzmann, R

    2015-06-01

    For diagnostic purposes, optical imaging techniques need to obtain high-resolution images of extended biological specimens in reasonable time. The field of view of an objective lens, however, is often smaller than the sample size. To image the whole sample, laser scanning microscopes acquire tile scans that are stitched into larger mosaics. The appearance of such image mosaics is affected by visible edge artefacts that arise from various optical aberrations which manifest in grey level jumps across tile boundaries. In this contribution, a technique for stitching tiles into a seamless mosaic is presented. The stitching algorithm operates by equilibrating neighbouring edges and forcing the brightness at corners to a common value. The corrected image mosaics appear to be free from stitching artefacts and are, therefore, suited for further image analysis procedures. The contribution presents a novel method to seamlessly stitch tiles captured by a laser scanning microscope into a large mosaic. The motivation for the work is the failure of currently existing methods for stitching nonlinear, multimodal images captured by our microscopic setups. Our method eliminates the visible edge artefacts that appear between neighbouring tiles by taking into account the overall illumination differences among tiles in such mosaics. The algorithm first corrects the nonuniform brightness that exists within each of the tiles. It then compensates for grey level differences across tile boundaries by equilibrating neighbouring edges and forcing the brightness at the corners to a common value. After these artefacts have been removed further image analysis procedures can be applied on the microscopic images. Even though the solution presented here is tailored for the aforementioned specific case, it could be easily adapted to other contexts where image tiles are assembled into mosaics such as in astronomical or satellite photos.

  7. Body-wide anatomy recognition in PET/CT images

    Science.gov (United States)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.

    2015-03-01

    With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.

  8. Was magnetic resonance imaging scan contraindicated?

    Science.gov (United States)

    Rafiq, Muhammad Khizar

    2010-01-01

    An intravenous drug abuser with a retained needle posed a management problem at a neurosurgical unit, having declined magnetic resonance imaging (MRI) on safety grounds. However, later, having been assessed by the senior radiologist, she went though the MRI scan safely.

  9. Digital forensic osteology: morphological sexing of skeletal remains using volume-rendered cranial CT scans.

    Science.gov (United States)

    Ramsthaler, Frank; Kettner, Mattias; Gehl, Axel; Verhoff, M A

    2010-02-25

    Because of the increasing lack of recent bone collections, ethical issues concerning maceration procedures, and progress in radiological imaging techniques, computed tomography (CT) scans offer an alternative to traditional anthropological bone collection. The present study examined volume-rendered cranial CT (CCT) scans from 50 crania to morphologically evaluate sex characteristics. CCT scans were performed and scored by two teams (Teams A and B) of two examiners each (2x50=100 examinations) to evaluate the occurrence and/or absence of morphological traits. Altogether, 60 of 100 crania (31 Team A+29 Team B) crania were determined to be male, and 40 (19 Team A+21 Team B) were determined to be female when using the scoring system adapted from Knussmann. These results imply a sex determination accuracy rate of 96%. Only in one case was recalculation of weighting factors necessary to determine one additional correct classification. As a single parameter, arcus superciliaris evaluation permitted the most accurate sex determination (female, 84.2%; male, 85.5%). No significant difference in accuracy rates was observed between the two sexes (p<0.65, chi(2)=0.39, Fisher's exact test). Interobserver bias rates for both teams were very low (kappa=0.83). The present study shows that volume-rendered CCT images are suitable for the collection of data concerning morphologic sex determination of skulls. Thus, this method may be helpful in both actual forensic casework and the systematic reevaluation and improvement of classical anthropological methods and their adaptation to changing populations.

  10. Pitfalls and Limitations of PET/CT in Brain Imaging.

    Science.gov (United States)

    Salmon, Eric; Bernard Ir, Claire; Hustinx, Roland

    2015-11-01

    Neurologic applications were at the forefront of PET imaging when the technique was developed in the mid-1970s. Although oncologic indications have become prominent in terms of number of studies performed worldwide, neurology remains a major field in which functional imaging provides unique information, both for clinical and research purposes. The evaluation of glucose metabolism using FDG remains the most frequent exploration, but in recent years, alternative radiotracers have been developed, including fluorinated amino acid analogues for primary brain tumor imaging and fluorinated compounds for assessing the amyloid deposits in patients with suspected Alzheimer disease. As the brain is enclosed in the skull, which presents fixed landmarks, it is relatively easy to coregister images obtained with various cross-sectional imaging methods, either functional or anatomical, with a relatively high accuracy and robustness. Nevertheless, PET in neurology has fully benefited from the advent of hybrid imaging. Attenuation and scatter correction is now much faster and equally accurate, using CT as compared with the traditional transmission scan using an external radioactive source. The perfect coregistration with the CT data, which is now systematically performed, also provides its own set of valuable information, for instance regarding cerebral atrophy. However, hybrid imaging in neurology comes with pitfalls and limitations, in addition to those that are well known, for example, blood glucose levels or psychotropic drugs that greatly affect the physiological FDG uptake. Movements of the patient's head, either during the PET acquisition or between the PET and the CT acquisitions will generate artifacts that may be very subtle yet lead to erroneous interpretation of the study. Similarly, quantitative analysis, such as voxel-based analyses, may prove very helpful in improving the diagnostic accuracy and the reproducibility of the reading, but a wide variety of artifacts may

  11. CT imaging, then and now: a 30-year review of the economics of computed tomography.

    Science.gov (United States)

    Stockburger, Wayne T

    2004-01-01

    The first computed tomography (CT) scanner in the US was installed in June 1973 at the Mayo Clinic in Rochester, MN. By the end of 1974, 44 similar systems had been installed at medical facilities around the country. Less than 4 years after the introduction of CT imaging in the US, at least 400 CT systems had been installed. The practice of pneumoencephalography was eliminated. The use of nuclear medicine brain scans significantly diminished. At the time, CT imaging was limited to head studies, but with the introduction of contrast agents and full body CT systems the changes in the practice of medicine became even more significant. CT imaging was hailed by the US medical community as the greatest advance in radiology since the discovery of x-rays. But the rapid spread of CT systems, their frequency of use, and the associated increase in healthcare costs combined to draw the attention of decision-makers within the federal and state governments, specifically to establish policies regarding the acquisition and use of diagnostic technologies. Initially, CT imaging was limited to neurological applications, but in the 30 years since its inception, capabilities and applications have been expanded as a result of the advancements in technology and software development. While neurological disorders are still a common reason for CT imaging, many other medical disciplines (oncology, emergency medicine, orthopedics, etc.) have found CT imaging to be the definitive tool for diagnostic information. As such, the clinical demand for CT imaging has steadily increased. Economically, the development of CT imaging has been one of success, even in the face of governmental action to restrict its acquisition and utilization by healthcare facilities. CTimaging has increased the cost of healthcare, but in turn has added unquantifiable value to the practice of medicine in the US.

  12. Comparative study on developmental stages of the clavicle by postmortem MRI and CT imaging

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels; Jensen, K.E.

    2013-01-01

    Objectives: The developmental stages of the clavicles are important for forensic age estimation purposes in adolescents. This study compares the 4-stage system to evaluate the ossification of the medial end of the clavicle as visualized by magnetic resonance imaging (MRI) and computed tomography...... (CT). As several forensic institutes routinely perform CT scans, the large amount of available data may serve as reference sample for MRI in specific cases. Material and methods: This prospective study included an MRI and CT scan of 47 autopsy cases performed prior to medico-legal autopsy (age range...

  13. Angiogenesis in tissue-engineered nerves evaluated objectively using MICROFIL perfusion and micro-CT scanning

    Institute of Scientific and Technical Information of China (English)

    Hong-kui Wang; Ya-xian Wang; Cheng-bin Xue; Zhen-mei-yu Li; Jing Huang; Ya-hong Zhao; Yu-min Yang; Xiao-song Gu

    2016-01-01

    Angiogenesis is a key process in regenerative medicine generally, as well as in the speciifc ifeld of nerve regeneration. However, no conve-nient and objective method for evaluating the angiogenesis of tissue-engineered nerves has been reported. In this study, tissue-engineered nerves were constructedin vitro using Schwann cells differentiated from rat skin-derived precursors as supporting cells and chitosan nerve conduits combined with silk ifbroin ifbers as scaffolds to bridge 10-mm sciatic nerve defects in rats. Four weeks after surgery, three-di-mensional blood vessel reconstructions were made through MICROFIL perfusion and micro-CT scanning, and parameter analysis of the tissue-engineered nerves was performed. New blood vessels grew into the tissue-engineered nerves from three main directions: the prox-imal end, the distal end, and the middle. The parameter analysis of the three-dimensional blood vessel images yielded several parameters, including the number, diameter, connection, and spatial distribution of blood vessels. The new blood vessels were mainly capillaries and microvessels, with diameters ranging from 9 to 301µm. The blood vessels with diameters from 27 to 155µm accounted for 82.84% of the new vessels. The microvessels in the tissue-engineered nerves implantedin vivo were relatively well-identiifed using the MICROFIL perfusion and micro-CT scanning method, which allows the evaluation and comparison of differences and changes of angiogenesis in tis-sue-engineered nerves implantedin vivo.

  14. The use of CT-scanning at the medicolegal external postmortem examination and at the forensic autopsy

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2006-01-01

    Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn and Sønde......Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn...... and Sønderjylland) (15 females and 45 males) were CT-scanned before autopsy. Method: A double-blind prospective investigation of CT-scanning in autopsy cases. A multislice spiral CT-scanner (Siemens Somatom Spirit) was used. Data from the CT-scanning and the autopsy were registered in a computer database...

  15. CT muscle scanning in the evaluation of patients with spinal muscular atrophy (SMA)

    Energy Technology Data Exchange (ETDEWEB)

    Sambrook, P.; Rickards, D.; Cumming, W.J.K.

    1988-12-01

    One hundred with spinal muscular atrophy (SMA) were assessed by CT scanning using a standardised technique. The spectrum of CT abnormality occurring in SMA was observed and by overall analysis the patients were divided into 4 groups. While the CT appearances of these groups correlated well with clinical assessment of severity of disease, the disease process was usually much more widespread than clinical examination suggested. CT abnormality was first observed in the leg and gluteal muscles, progressing to the posterior spinal, thigh, shoulder girdle and sternomastoid muscles. Hypertrophy of sartorius and gracilis was observed in a significant number of patients. Fascial planes were preserved in involved muscles in over half of the patients, even in late-stage disease. Asymmetrical muscle involvement was seen with increasing frequency as the disease process increased in extent as evaluated by CT scanning. There was no discernible difference in the CT appearances in those patients who clinically had limb-girdle, facioscapulohumeral or scapuloperoneal distribution of weakness.

  16. Is it possible to limit the use of CT scanning in acute diverticular disease without compromising outcomes? A preliminary experience.

    Science.gov (United States)

    Caputo, Pierpaolo; Rovagnati, Marco; Carzaniga, Pier Luigi

    2015-01-01

    The aim of our study was to determine whether the use of CT scanning in the assessment of acute diverticulitis can be reduced without a negative effect on outcome. Our series consisted of 93 out of 100 patients with acute diverticulitis admitted to the Emergency Room of our institution in the period from February 2012 to March 2013.The Hinchey classification system was used to stage disease based on findings on ultrasound (US) examination and/or computed tomography (CT) scanning. We compared the patients' Hinchey stage (HS) on admission and 72 hours later. Types of treatment were defined as emergency or delayed intervention (operative approaches (OA); ultrasound-guided percutaneous drainage (UPD), and surgery. The borderline between conservative and surgical management was identified. In patients with a HS imaging is sufficient and they can be spared the exposure to ionizing radiation associated with CT scans. The skill of the individual operator in US examination was found to be of key importance. As regards CT scanning, we found, in agreement with the literature, that it has greater specificity and sensitivity than US, and is therefore indicated if the patient's condition has deteriorated.

  17. Impact of miscentering on patient dose and image noise in x-ray CT imaging : Phantom and clinical studies

    NARCIS (Netherlands)

    Habibzadeh, M. A.; Ay, M. R.; Asl, A. R. Kamali; Ghadiri, H.; Zaidi, H.

    The operation of the bowtie filter in x-ray CT is correct if the object being scanned is properly centered in the scanner's field-of-view. Otherwise, the dose delivered to the patient and image noise will deviate from optimal setting. We investigate the effect of miscentering on image noise and

  18. Impact of miscentering on patient dose and image noise in x-ray CT imaging : Phantom and clinical studies

    NARCIS (Netherlands)

    Habibzadeh, M. A.; Ay, M. R.; Asl, A. R. Kamali; Ghadiri, H.; Zaidi, H.

    2012-01-01

    The operation of the bowtie filter in x-ray CT is correct if the object being scanned is properly centered in the scanner's field-of-view. Otherwise, the dose delivered to the patient and image noise will deviate from optimal setting. We investigate the effect of miscentering on image noise and surf

  19. Incidental Detection of Interstitial Pregnancy on CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of)

    2010-02-15

    Ectopic pregnancy is a potentially life-threatening condition. Detection of ectopic pregnancy on CT images is rare. In this case, we describe the CT findings of interstitial pregnancy both before and after rupture. If CT images demonstrate the presence of a strong enhancing ring-like mass in the pelvis, ectopic pregnancy should be considered

  20. A low density area along the ventricular catheter on CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yasuo; Ishii, Ryoji; Watanabe, Akira; Hirano, Kazuhiro; Kamada, Masaki; Okamura, Hironari (Kawasaki Medical School, Kurashiki, Okayama (Japan))

    1990-12-01

    Ten patients with hydrocephalus due to various causes, such as subarachnoid or intraventricular hemorrhage, had low density area (LDA) along the ventricular catheter on CT scans. This is an analysis of the 10 patients, with a discussion of the etiology. Ventriculoperitoneal (VS) shunt was performed in 8 patients, and 3 underwent ventricular drainage. None of the patients had postoperative hemorrhage. According to CT findings, the patients were divided into three groups. The first group consisted of 3 patients whose CT scans showed progressive ventricular dilatation and a presence of LDA along the ventricular catheter. After surgical resolution of high intraventricular pressure, repeated CT scans showed a remarkably decreased ventricles and LDA. In this group, an increased intraventricular pressure may play an important role in the formation of LDA. In the second group consisting of 3 patients, there was no postoperative CT evidence of progressive ventricular dilatation, but LDA was present. Follow-up CT scans revealed a decreased lesion. A slightly increased intraventricular pressure may result in LDA. In the last group of 4 patients, CT scans showed a small, irregular, marginal LDA along the ventricular catheter, with no evidence of increased ventricle. On repeated CT scans after conservative treatment, the lesion persisted for several years after VP shunt. There was a good correlation between CT findings and patient age. Children seemed to have a large porencephalic cyst. In conclusion, LDA may be an accumulation of CSF within the unresisting white matter along the ventricular catheter due to increased intraventricular pressure. Various CT patterns seem to depend on the increased degree of intraventricular pressure and the compliance of the surrounding white matter. (N.K.).

  1. Evaluation of reformatted sagittal CT images for measurement of condylar position. Comparison between original axial and coronal images

    Energy Technology Data Exchange (ETDEWEB)

    Hiruma, Takayoshi; Funato, Masahiko; Suganuma, Takeshi; Shinya, Akiyuki; Furuya, Ryoichi; Kawawa, Tadaharu; Seki, Kenji; Okano, Tomohiro [Showa Univ., Tokyo (Japan). School of Dentistry

    1995-09-01

    Accurate measurement of the condylar position is important for diagnosis and treatment of temporomandibular joint dysfunction. Conventional radiographic techniques have been used for this purpose and the recent advance of computed tomography (CT) is applicable to temporomandibular joints. The accuracy of CT in the measurement of the condylar position is still unclear. The purpose of this study was to evaluate the measurement accuracy of the condylar position on reformatted sagittal CT images. Six TMJs obtained from dried skulls were used. The TMJs were examined using a CT scanner with 1 mm thickness/interval in the axial and coronal directions. The visibility of the condyle and fossa on the reformatted sagittal images created were evaluated by measuring the joint space defined in our study. The results were as follows: (1) The superior surface of the condyle and the deepest part of the fossa were obscured in the reformatted images created from the axial scan and coronal scan projected at 60deg to the F-H plane. (2) The reformatted images from the coronal scan projected at 90deg, 80deg or 70deg to the F-H plane clearly depicted the condyle and fossa, the reproducibility of the measurement on these images mentioned above was less than 0.1 mm. The results indicated that the coronal scan from 90deg to 70deg to the F-H plane is more accurate than the axial scan for determining the condylar position on the reformatted sagittal images. (author).

  2. Coronal CT scan of paranasal sinuses; Long survey after Caldwell-Luc operation

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko (Tokyo Metropolitan Komagome Hospital (Japan)); Ikeda, Motohisa; Watanabe, Isamu; Komatsuzaki, Atsushi

    1994-03-01

    The clinical features were correlated with the coronal CT scan appearance of the paranasal sinuses of 49 patients who had received the Caldwell-Luc operation 16 to 58 years ago. The clinical diagnosis at the time of the CT scan was postoperative maxillary cyst in 22 patients, chronic sinusitis in 21 patients, trigeminal neuralgia in 3 patients, radicular cyst, postoperative ethmoid cyst and inverted papilloma in one patient each. The CT scans of the 91 operated maxillary sinuses showed obliterated cavity in 21 cases, small cavity in 46 cases, and cystic formation in 24 cases. The authors speculated that some maxillary sinuses which appeared in CT scans as small cavities might cause the clinical symptoms of postoperative maxillary cyst in the future. (author).

  3. Functional CT imaging of prostate cancer

    Science.gov (United States)

    Henderson, Elizabeth; Milosevic, Michael F.; Haider, Masoom A.; Yeung, Ivan W. T.

    2003-09-01

    The purpose of this paper is to investigate the distribution of blood flow (F), mean capillary transit time (Tc), capillary permeability (PS) and blood volume (vb) in prostate cancer using contrast-enhanced CT. Nine stage T2-T3 prostate cancer patients were enrolled in the study. Following bolus injection of a contrast agent, a time series of CT images of the prostate was acquired. Functional maps showing the distribution of F, Tc, PS and vb within the prostate were generated using a distributed parameter tracer kinetic model, the adiabatic approximation to the tissue homogeneity model. The precision of the maps was assessed using covariance matrix analysis. Finally, maps were compared to the findings of standard clinical investigations. Eight of the functional maps demonstrated regions of increased F, PS and vb, the locations of which were consistent with the results of standard clinical investigations. However, model parameters other than F could only be measured precisely within regions of high F. In conclusion functional CT images of cancer-containing prostate glands demonstrate regions of elevated F, PS and vb. However, caution should be used when applying a complex tracer kinetic model to the study of prostate cancer since not all parameters can be measured precisely in all areas.

  4. Definitive role of CT scanning of the pancreas. The second year's experience.

    Science.gov (United States)

    Haaga, J R; Alfidi, R J; Havrilla, T R; Tubbs, R; Gonzalez, L; Meaney, T F; Corsi, M A

    1977-09-01

    In a group of 188 patients, 192 computed tomographic (CT) scans of the pancreas were done, and the diagnostic accuracy of CT determined relative to other modalities. CT was the most effective method of detecting neoplastic and inflammatory diseases. The full extent of the disease process, including involvement of the retroperitoneum and metastasis to the liver, was visualized with one examination. Calcification and cystic collections associated with pancreatitis were also clearly seen.

  5. Computer-aided detection and quantification of cavitary tuberculosis from CT scans

    Science.gov (United States)

    Xu, Ziyue; Bagci, Ulas; Kubler, Andre; Luna, Brian; Jain, Sanjay; Bishai, William R.; Mollura, Daniel J.

    2013-01-01

    Purpose: To present a computer-aided detection tool for identifying, quantifying, and evaluating tuberculosis (TB) cavities in the infected lungs from computed tomography (CT) scans. Methods: The authors’ proposed method is based on a novel shape-based automated detection algorithm on CT scans followed by a fuzzy connectedness (FC) delineation procedure. In order to assess interaction between cavities and airways, the authors first roughly identified air-filled structures (airway, cavities, esophagus, etc.) by thresholding over Hounsfield unit of CT image. Then, airway and cavity structure detection was conducted within the support vector machine classification algorithm. Once airway and cavities were detected automatically, the authors extracted airway tree using a hybrid multiscale approach based on novel affinity relations within the FC framework and segmented cavities using intensity-based FC algorithm. At final step, the authors refined airway structures within the local regions of FC with finer control. Cavity segmentation results were compared to the reference truths provided by expert radiologists and cavity formation was tracked longitudinally from serial CT scans through shape and volume information automatically determined through the authors’ proposed system. Morphological evolution of the cavitary TB were analyzed accordingly with this process. Finally, the authors computed the minimum distance between cavity surface and nearby airway structures by using the linear time distance transform algorithm to explore potential role of airways in cavity formation and morphological evolution. Results: The proposed methodology was qualitatively and quantitatively evaluated on pulmonary CT images of rabbits experimentally infected with TB, and multiple markers such as cavity volume, cavity surface area, minimum distance from cavity surface to the nearest bronchial-tree, and longitudinal change of these markers (namely, morphological evolution of cavities) were

  6. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  7. The presence and progression of emphysema in COPD as determined by CT scanning and biomarker expression

    DEFF Research Database (Denmark)

    Coxson, Harvey O; Dirksen, Asger; Edwards, Lisa D

    2013-01-01

    Emphysema is a key contributor to airflow limitation in chronic obstructive pulmonary disease (COPD) and can be quantified using CT scanning. We investigated the change in CT lung density in a longitudinal, international cohort of patients with COPD. We also explored the potential relation betwee...

  8. Patient-centered clinical impact of incidentally detected abnormalities on chest CT scans

    Directory of Open Access Journals (Sweden)

    Sherine G. Moftah

    2014-09-01

    Conclusion: The clinically significant different incidental abnormalities on chest CT scans represented 10.4% of all incidental findings, 3.3% were due to malignancies. The clinical impact of incidental abnormalities on chest CT may be of utmost importance on patient care.

  9. Prognostic Value of Gastric Bare Area & Left Adrenal Gland Involvement in Acute Pancreatitis on Abdominal CT SCAN

    Directory of Open Access Journals (Sweden)

    Saeed Naghibi

    2009-01-01

    Full Text Available "nIntroduction: The CT severity index (CTSI proposed by Baithazar is a well-defined scoring system and has proved to be an excellent prognostic tool in predicting complications and mortality in patients with acute pancreatitis .But new investigations demonstrate that the other findings on abdominal CT scan in acute pancreatitis impression on prognostic outcome (involvement of abdominal viscera. Therefore the newer scoring system has been proposed. In our study the involvement of gastric bare area & left adrenal gland in CT scan is usually associated with a more severe clinical course. "nMaterials and Methods: This study was a retrospective & prospective evaluation in 22-Bahman Hospital of AZAD University of Mashhad from 2006 to 2008 .78 patients with acute pancreatitis (based on a typical clinical presentation & an elevated serum amylase level and "or pathologic findings had undergone the abdominal spiral CT scan with oral & IV contrast (if necesary. 28 cases were excluded from the study population for the following reasons: CT was not performed (n=10 ; CT images were not available (n=13; inadequate data analysis (n=2; and acute pancreatitis was not the first episode (n=3. "nFollow-up CT was performed within 1 week after the initial CT. Leaving 50 patients in our study there were 32 men and 18 women in the age range of 21-82 years (50.5+_ 18.2 years. All the patients underwent unenhanced CT followed by dual-phase contrast-enhanced CT. The arterial and portal venous phase data acquisition started at 25-30s and 60-65s after injection of contrast. Then two experienced abdominal radiologists recorded the findings of CT scan including the size,contour and density of the pancreas and manifestations of peripancreatic inflammation as well as the GBAI and LAGI involvement (haziness and streaky density with fluid collection in the gastric bare area and deformity with ill-defined margin and hypodensity of the left adrenal gland on unenhanced or contrast

  10. 3D Interpolation Method for CT Images of the Lung

    Directory of Open Access Journals (Sweden)

    Noriaki Asada

    2003-06-01

    Full Text Available A 3-D image can be reconstructed from numerous CT images of the lung. The procedure reconstructs a solid from multiple cross section images, which are collected during pulsation of the heart. Thus the motion of the heart is a special factor that must be taken into consideration during reconstruction. The lung exhibits a repeating transformation synchronized to the beating of the heart as an elastic body. There are discontinuities among neighboring CT images due to the beating of the heart, if no special techniques are used in taking CT images. The 3-D heart image is reconstructed from numerous CT images in which both the heart and the lung are taken. Although the outline shape of the reconstructed 3-D heart is quite unnatural, the envelope of the 3-D unnatural heart is fit to the shape of the standard heart. The envelopes of the lung in the CT images are calculated after the section images of the best fitting standard heart are located at the same positions of the CT images. Thus the CT images are geometrically transformed to the optimal CT images fitting best to the standard heart. Since correct transformation of images is required, an Area oriented interpolation method proposed by us is used for interpolation of transformed images. An attempt to reconstruct a 3-D lung image by a series of such operations without discontinuity is shown. Additionally, the same geometrical transformation method to the original projection images is proposed as a more advanced method.

  11. Segmentation-based CT image compression

    Science.gov (United States)

    Thammineni, Arunoday; Mukhopadhyay, Sudipta; Kamath, Vidya

    2004-04-01

    The existing image compression standards like JPEG and JPEG 2000, compress the whole image as a single frame. This makes the system simple but inefficient. The problem is acute for applications where lossless compression is mandatory viz. medical image compression. If the spatial characteristics of the image are considered, it can give rise to a more efficient coding scheme. For example, CT reconstructed images have uniform background outside the field of view (FOV). Even the portion within the FOV can be divided as anatomically relevant and irrelevant parts. They have distinctly different statistics. Hence coding them separately will result in more efficient compression. Segmentation is done based on thresholding and shape information is stored using 8-connected differential chain code. Simple 1-D DPCM is used as the prediction scheme. The experiments show that the 1st order entropies of images fall by more than 11% when each segment is coded separately. For simplicity and speed of decoding Huffman code is chosen for entropy coding. Segment based coding will have an overhead of one table per segment but the overhead is minimal. Lossless compression of image based on segmentation resulted in reduction of bit rate by 7%-9% compared to lossless compression of whole image as a single frame by the same prediction coder. Segmentation based scheme also has the advantage of natural ROI based progressive decoding. If it is allowed to delete the diagnostically irrelevant portions, the bit budget can go down as much as 40%. This concept can be extended to other modalities.

  12. Speckle Scanning Based X-ray Imaging

    CERN Document Server

    Berujon, Sebastien

    2015-01-01

    The X-ray near field speckle scanning concept is an approach recently introduced to obtain absorption, phase and darkfield images of a sample. In this paper, we demonstrate ways of recovering from a sample its ultra-small angle X-ray scattering distribution using numerical deconvolution, and the 2D phase gradient signal from random step scans, the latter being used to elude the flat field correction error. Each feature is explained theoretically and demonstrated experimentally at a synchrotron X-ray facility.

  13. Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries.

    Science.gov (United States)

    Liu, Fenglin; Yu, Hengyong; Cong, Wenxiang; Wang, Ge

    2014-01-01

    The goal is to develop new architectures for computed tomography (CT) which are at an ultra-low-cost for developing countries, especially in rural areas. The proposed general scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. Similar to linear tomosynthesis, the source and detector are translated in opposite directions but in contrast to conventional tomosynthesis, our proposal is for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In other words, the popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. The various translational scanning modes are theoretically analyzed, and the scanning parameters are optimized. The numerical simulation results from different numbers of linear scans confirm the feasibility of the proposed scheme, and suggest two preferred low-end systems for horizontal and vertical patient positions respectively. Ultra-low-cost x-ray CT is feasible with our proposed combination of linear scanning, compressive sensing, and interior tomography. The proposed architecture can be tailored into permanent, movable, or reconfigurable systems as desirable. Advanced image registration and spectral imaging features can be included as well.

  14. CT-Scans of Cochlear Implant Patients with Characteristics of Pendred Syndrome

    Directory of Open Access Journals (Sweden)

    Sebastian Roesch

    2013-12-01

    Full Text Available Background: Sensorineural hearing loss (SNHL in newborns is estimated with an incidence around 1:10,000 per year and is divided into syndromic and non-syndromic forms. In case of present retrocochlear function‚ cochlear implantation allows speech and cognitive development in affected children, comparable to that of normal hearing children. Pathogenesis of SNHL remains unclear in many cases. Imaging of the temporal bone, such as computed tomography (CT and magnetic resonance imaging (MRI, can reveal conspicuous findings, e.g. enlarged vestibular aqueduct (EVA and Mondini malformation (MM of the cochlea. These malformations can be a clinical sign for Pendred syndrome. Methods: We screened CT scans of 75 cochlear implant patients for EVA and MM. Results: Six patients were observed to have either EVA alone (n=3, or MM alone (n=2, or a combination of both (n=1. Further malformations of the temporal bone could be found within the whole group, as well. Conclusion: Our results confirm the general opinion on EVA and MM, being commonly found in patients with SNHL. A possible association with Pendred syndrome needs to be confirmed by genetic investigations with search for mutations in the SLC26A4 gene and further clinical tests, such as Perchlorate test for surveillance of thyroid function.

  15. CT-scans of cochlear implant patients with characteristics of Pendred syndrome.

    Science.gov (United States)

    Roesch, Sebastian; Moser, Gerhard; Rasp, Gerd; Tóth, Miklós

    2013-01-01

    Sensorineural hearing loss (SNHL) in newborns is estimated with an incidence around 1:10,000 per year and is divided into syndromic and non-syndromic forms. In case of present retrocochlear function' cochlear implantation allows speech and cognitive development in affected children, comparable to that of normal hearing children. Pathogenesis of SNHL remains unclear in many cases. Imaging of the temporal bone, such as computed tomography (CT) and magnetic resonance imaging (MRI), can reveal conspicuous findings, e.g. enlarged vestibular aqueduct (EVA) and Mondini malformation (MM) of the cochlea. These malformations can be a clinical sign for Pendred syndrome. We screened CT scans of 75 cochlear implant patients for EVA and MM. Six patients were observed to have either EVA alone (n=3), or MM alone (n=2), or a combination of both (n=1). Further malformations of the temporal bone could be found within the whole group, as well. Our results confirm the general opinion on EVA and MM, being commonly found in patients with SNHL. A possible association with Pendred syndrome needs to be confirmed by genetic investigations with search for mutations in the SLC26A4 gene and further clinical tests, such as Perchlorate test for surveillance of thyroid function. © 2014 S. Karger AG, Basel.

  16. Increase in dicentric chromosome formation after a single CT scan in adults.

    Science.gov (United States)

    Abe, Yu; Miura, Tomisato; Yoshida, Mitsuaki A; Ujiie, Risa; Kurosu, Yumiko; Kato, Nagisa; Katafuchi, Atsushi; Tsuyama, Naohiro; Ohba, Takashi; Inamasu, Tomoko; Shishido, Fumio; Noji, Hideyoshi; Ogawa, Kazuei; Yokouchi, Hiroshi; Kanazawa, Kenya; Ishida, Takashi; Muto, Satoshi; Ohsugi, Jun; Suzuki, Hiroyuki; Ishikawa, Tetsuo; Kamiya, Kenji; Sakai, Akira

    2015-09-09

    Excess risk of leukemia and brain tumors after CT scans in children has been reported. We performed dicentric chromosome assay (DCAs) before and after CT scan to assess effects of low-dose ionizing radiation on chromosomes. Peripheral blood (PB) lymphocytes were collected from 10 patients before and after a CT scan. DCA was performed by analyzing either 1,000 or 2,000 metaphases using both Giemsa staining and centromere-fluorescence in situ hybridization (Centromere-FISH). The increment of DIC formation was compared with effective radiation dose calculated using the computational dosimetry system, WAZA-ARI and dose length product (DLP) in a CT scan. Dicentric chromosome (DIC) formation increased significantly after a single CT scan, and increased DIC formation was found in all patients. A good correlation between the increment of DIC formation determined by analysis of 2,000 metaphases using Giemsa staining and those by 2,000 metaphases using Centromere-FISH was observed. However, no correlation was observed between the increment of DIC formation and the effective radiation dose. Therefore, these results suggest that chromosome cleavage may be induced by one CT scan, and we recommend 2,000 or more metaphases be analyzed in Giemsa staining or Centromere-FISH for DCAs in cases of low-dose radiation exposure.

  17. A microPET/CT system for invivo small animal imaging

    Science.gov (United States)

    Liang, H.; Yang, Y.; Yang, K.; Wu, Y.; Boone, J. M.; Cherry, S. R.

    2007-07-01

    A microCT scanner was designed, fabricated and integrated with a previously reported microPET II scanner (Tai et al 2003 Phys. Med. Biol. 48 1519, Yang et al 2004 Phys. Med. Biol. 49 2527), forming a dual modality system for in vivo anatomic and molecular imaging of the mouse. The system was designed to achieve high-spatial-resolution and high-sensitivity PET images with adequate CT image quality for anatomic localization and attenuation correction with low x-ray dose. The system also has relatively high throughput for screening, and a flexible gantry and user interface. X-rays were produced by a 50 kVp, 1.5 mA fixed tungsten anode tube, with a focal spot size of 70 µm. The detector was a 5 × 5 cm2 photodiode detector incorporating 48 µm pixels on a CMOS array and a fast gadolinium oxysulfide (GOS) intensifying screen. The microCT system has a flexible C-arm gantry design with adjustable detector positioning, which acquires CT projection images around the common microPET/CT bed. The design and the initial characterization of the microCT system is described, and images of the first mouse scans with microPET/CT scanning protocols are shown.

  18. A microPET/CT system for invivo small animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liang, H [Department of Biomedical Engineering, University of California, Davis, GBSF Building, 451 East Health Sciences Drive, Davis, CA 95616 (United States); Yang, Y [Department of Biomedical Engineering, University of California, Davis, GBSF Building, 451 East Health Sciences Drive, Davis, CA 95616 (United States); Yang, K [Department of Radiology, UC Davis Medical Center, 4701 X Street, X-ray Imaging Laboratory, Sacramento, CA 95817 (United States); Wu, Y [Department of Biomedical Engineering, University of California, Davis, GBSF Building, 451 East Health Sciences Drive, Davis, CA 95616 (United States); Boone, J M [Department of Biomedical Engineering, University of California, Davis, GBSF Building, 451 East Health Sciences Drive, Davis, CA 95616 (United States); Cherry, S R [Department of Biomedical Engineering, University of California, Davis, GBSF Building, 451 East Health Sciences Drive, Davis, CA 95616 (United States)

    2007-07-07

    A microCT scanner was designed, fabricated and integrated with a previously reported microPET II scanner (Tai et al 2003 Phys. Med. Biol. 48 1519, Yang et al 2004 Phys. Med. Biol. 49 2527), forming a dual modality system for in vivo anatomic and molecular imaging of the mouse. The system was designed to achieve high-spatial-resolution and high-sensitivity PET images with adequate CT image quality for anatomic localization and attenuation correction with low x-ray dose. The system also has relatively high throughput for screening, and a flexible gantry and user interface. X-rays were produced by a 50 kVp, 1.5 mA fixed tungsten anode tube, with a focal spot size of 70 {mu}m. The detector was a 5 x 5 cm{sup 2} photodiode detector incorporating 48 {mu}m pixels on a CMOS array and a fast gadolinium oxysulfide (GOS) intensifying screen. The microCT system has a flexible C-arm gantry design with adjustable detector positioning, which acquires CT projection images around the common microPET/CT bed. The design and the initial characterization of the microCT system is described, and images of the first mouse scans with microPET/CT scanning protocols are shown.

  19. Sinusitis and intracranial sepsis: the CT imaging and clinical presentation

    Energy Technology Data Exchange (ETDEWEB)

    Saxton, V.J. [Dept. of Radiology, Royal Children`s Hospital, Melbourne (Australia); Boldt, D.W. [Dept. of Radiology, Royal Children`s Hospital, Melbourne (Australia); Shield, L.K. [Dept. of Neurology, Royal Children`s Hospital, Melbourne (Australia)

    1995-11-01

    The CT imaging and clinical presentation in 14 children with coexistent intracranial sepsis and sinusitis were reviewed. A routine CT head scan (10-mm thick semi-axial slices through the cranium done before and after intravenous contrast medium administration) was found to be an inadequate initial investigation as the intracranial collection was missed in four patients and the abnormal sinuses not shown in six. In half the children the dagnosis of sinusitis was unsuspected at the time of admission. The dominant clinical features were fever, intense headache and facial swelling in early adolescent males. In this clinical setting we recommend: (1) The routine scan is extended through the frontal and ethmoidal sinuses and photographed at a window level and width showing both bone detail and air/soft tissue interfaces; (2) direct coronal projections are performed through the anterior cranial fossa if no collection is seen on the routine study; (3) an early repeat scan within 48 h if the initial study shows no intracranial pathology but the fronto-ethomoidal sinuses are abnormal and there is a high clinical supicion of intracranial sepsis; and (4) in the presence of intracranial sepsis the vault is viewed at bone window settings to exclude cranial osteomyelitis. (orig.)

  20. Adapted Treatment Guided by Interim PET-CT Scan in Advanced Hodgkin's Lymphoma.

    Science.gov (United States)

    Johnson, Peter; Federico, Massimo; Kirkwood, Amy; Fosså, Alexander; Berkahn, Leanne; Carella, Angelo; d'Amore, Francesco; Enblad, Gunilla; Franceschetto, Antonella; Fulham, Michael; Luminari, Stefano; O'Doherty, Michael; Patrick, Pip; Roberts, Thomas; Sidra, Gamal; Stevens, Lindsey; Smith, Paul; Trotman, Judith; Viney, Zaid; Radford, John; Barrington, Sally

    2016-06-23

    We tested interim positron-emission tomography-computed tomography (PET-CT) as a measure of early response to chemotherapy in order to guide treatment for patients with advanced Hodgkin's lymphoma. Patients with newly diagnosed advanced classic Hodgkin's lymphoma underwent a baseline PET-CT scan, received two cycles of ABVD (doxorubicin, bleomycin, vinblastine, and dacarbazine) chemotherapy, and then underwent an interim PET-CT scan. Images were centrally reviewed with the use of a 5-point scale for PET findings. Patients with negative PET findings after two cycles were randomly assigned to continue ABVD (ABVD group) or omit bleomycin (AVD group) in cycles 3 through 6. Those with positive PET findings after two cycles received BEACOPP (bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone). Radiotherapy was not recommended for patients with negative findings on interim scans. The primary outcome was the difference in the 3-year progression-free survival rate between randomized groups, a noninferiority comparison to exclude a difference of 5 or more percentage points. A total of 1214 patients were registered; 937 of the 1119 patients (83.7%) who underwent an interim PET-CT scan according to protocol had negative findings. With a median follow-up of 41 months, the 3-year progression-free survival rate and overall survival rate in the ABVD group were 85.7% (95% confidence interval [CI], 82.1 to 88.6) and 97.2% (95% CI, 95.1 to 98.4), respectively; the corresponding rates in the AVD group were 84.4% (95% CI, 80.7 to 87.5) and 97.6% (95% CI, 95.6 to 98.7). The absolute difference in the 3-year progression-free survival rate (ABVD minus AVD) was 1.6 percentage points (95% CI, -3.2 to 5.3). Respiratory adverse events were more severe in the ABVD group than in the AVD group. BEACOPP was given to the 172 patients with positive findings on the interim scan, and 74.4% had negative findings on a third PET-CT scan; the 3-year progression

  1. Adapted Treatment Guided by Interim PET-CT Scan in Advanced Hodgkin’s Lymphoma

    Science.gov (United States)

    Johnson, Peter; Federico, Massimo; Kirkwood, Amy; Fosså, Alexander; Berkahn, Leanne; Carella, Angelo; d’Amore, Francesco; Enblad, Gunilla; Franceschetto, Antonella; Fulham, Michael; Luminari, Stefano; O’Doherty, Michael; Patrick, Pip; Roberts, Thomas; Sidra, Gamal; Stevens, Lindsey; Smith, Paul; Trotman, Judith; Viney, Zaid; Radford, John; Barrington, Sally

    2016-01-01

    Background We tested interim positron-emission tomography–computed tomography (PET-CT) as a measure of early response to chemotherapy in order to guide treatment for patients with advanced Hodgkin’s lymphoma. Methods Patients with newly diagnosed advanced classic Hodgkin’s lymphoma underwent a baseline PET-CT scan, received two cycles of ABVD (doxorubicin, bleomycin, vinblastine, and dacarbazine) chemotherapy, and then underwent an interim PET-CT scan. Images were centrally reviewed with the use of a 5-point scale for PET findings. Patients with negative PET findings after two cycles were randomly assigned to continue ABVD (ABVD group) or omit bleomycin (AVD group) in cycles 3 through 6. Those with positive PET findings after two cycles received BEACOPP (bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone). Radiotherapy was not recommended for patients with negative findings on interim scans. The primary outcome was the difference in the 3-year progression-free survival rate between randomized groups, a noninferiority comparison to exclude a difference of 5 or more percentage points. Results A total of 1214 patients were registered; 937 of the 1119 patients (83.7%) who underwent an interim PET-CT scan according to protocol had negative findings. With a median follow-up of 41 months, the 3-year progression-free survival rate and overall survival rate in the ABVD group were 85.7% (95% confidence interval [CI], 82.1 to 88.6) and 97.2% (95% CI, 95.1 to 98.4), respectively; the corresponding rates in the AVD group were 84.4% (95% CI, 80.7 to 87.5) and 97.6% (95% CI, 95.6 to 98.7). The absolute difference in the 3-year progression-free survival rate (ABVD minus AVD) was 1.6 percentage points (95% CI, −3.2 to 5.3). Respiratory adverse events were more severe in the ABVD group than in the AVD group. BEACOPP was given to the 172 patients with positive findings on the interim scan, and 74.4% had negative findings on a third

  2. Survey regarding the clinical practice of cardiac CT in Germany. Indications, scanning technique and reporting

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Marc H.; Hamm, B.; Dewey, M. [Inst. fuer Radiologie, Charite - Universitaetsmedizin Berlin (Germany)

    2009-12-15

    Purpose: to obtain an overview of the current clinical practice of cardiac computed tomography (CT) in Germany. Materials and methods: a 30-item question-naire was mailed to 149 providers of cardiac CT in Germany. The items asked about indications, scanning technique and reporting, data storage, and cost of the examination. Results: overall 45 questionnaires could be analyzed (30%). The majority of centers (76%, 34 of 45 centers) used CT scanners of the latest generation (at least 64 rows). The most common appropriate indications were exclusion of coronary artery disease (91%, 41/45), coronary anomalies (80%, 36/45), and follow-up after coronary artery bypass grafting (53%, 24/45). Each center examined on average 243 {+-} 310 patients in 2007 and the number of centers performing cardiac CT increased significantly in 2007 (p = 0.035) compared with the preceding year. Most used sublingual nitroglycerin (84%, 38/45; median of 2 sprays = 0.8 mg) and/or a beta blocker (86%, 39/44; median of 5 mg IV, median heart rate threshold: 70 beats/min). Many providers used ECG-triggered tube current modulation (65%, 29/44) and/or adjusted the tube current to the body mass index or body weight (63%, 28/44). A median slice thickness of 0.75 mm with a 0.5 mm increment and a 20 cm field-of-view was most commonly used. Source images in orthogonal planes (96%, 43/45), curved MPRs (93%, 42/45), and thin-slice MIPs (69%, 31/45) were used most frequently for interpretation. Extracardiac structures were also evaluated by 84% of the centers (38/45). The mean examination time was 16.2 min and reporting took an average of 28.8 min. (orig.)

  3. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  4. Advantage of CT scan in muscular pathology. Personal cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Laroche, M.; Rousseau, H.; Mazieres, B.; Bonafe, A.; Joffre, F.; Arlet, J.

    1989-05-01

    The advantage of CT scans in muscular pathology is studied. The scan, in addition to the diagnosis of tumors and muscular abscesses, permits to differentiate primary myopathies from neurogenic atrophies: in the course of myopathies, the muscle volume is preserved and they appear as a hypodensity; in neurogenic atrophies, the muscle volume is reduced with preserved density. The CT scan permits to determine the extension of these lesions. In the course of polymyositis, certain forms of rheumatid arthritis, the scan discloses a trabecular and 'worm-eaten' aspect of the muscles. This is also observed after long-term steroid therapy and other endocrine diseases (hyperthyroidism, osteomalacia) indicating an infra-clinical myopathy. In vertebral osteoporosis with fractures and patients with chronic lumbalgia, very ofter, an atrophy of the spinal muscle is observed. Finally, in the course of acquired kyphosis of the adult patient (camptocormia), the CT scan suggest an isolated myopathy, with late manifestations, of the paravertebral muscles.

  5. Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: Comparison with retrospective ECG gating

    Energy Technology Data Exchange (ETDEWEB)

    Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yang Lin, E-mail: anna7949@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Li Yu, E-mail: athen06@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Xiaohai, E-mail: maxi8238@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lv Biao, E-mail: biao_lu2007@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2010-11-15

    Purpose: To explore feasibility of dual-source CT (DS-CT) prospective ECG-gated coronary angiography in patients with heart rate (HR) higher than 70 beat per minute (bpm), and evaluate image quality and radiation dose with comparison to retrospective ECG-gated spiral scan. Materials and methods: One hundred patients who underwent DS-CT coronary angiography (DS-CTCA) with mean HR higher than 70 bpm but below 110 bpm were enrolled in the study, 50 were scanned by adaptive sequential scan and another 50 were analyzed by retrospectively gated CT scan. The imaging quality of coronary artery segments in the two groups was evaluated using a four-point grading scale by two independent reviewers. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. Results: There was no significant difference between the two groups for mean HR (p = 0.305), HR variability (p = 0.103), body mass index (p = 0.472), and scan length (p = 0.208). There was good agreement for image quality scoring between the two reviewers (Kappa = 0.72). Coronary evaluability of adaptive sequential scan was 99.7% (608 of 610 segments), while that of retrospective gated scan was 98.7% (614 of 622 segments), showing similar coronary evaluability (p = 0.061). Effective doses of adaptive sequential scan and retrospective gated scan were 5.1 {+-} 1.6 and 11.8 {+-} 4.5 mSv, respectively (p < 0.001), showing that adaptive sequential scan reduced radiation dose by 57% compared with that of retrospective gated scan. Conclusions: In patients with 70-110 bpm HR, DS-CTCA adaptive sequential scan shows similar image quality as retrospective ECG-gated spiral scan with 57% reduction of radiation dose.

  6. Effect of large contrast agent dose and prolong scanning time on the image quality of CT portal venous phase images in patients with liver cirrhosis%延长扫描时间和大剂量对比剂对肝硬化患者门静脉期CT图像质量的影响

    Institute of Scientific and Technical Information of China (English)

    鲁慧; 杨剑

    2014-01-01

    目的:探讨大剂量对比剂及延长扫描时间对肝硬化患者门静脉期CT图像质量的影响。方法选取75例肝硬化患者,其中采用常规时间常规剂量扫描(60 s,1.5 ml/kg)患者为对照组(25例),延长扫描时间(70 s)患者为延长组(25例),在延长扫描时间的基础上增加对比剂剂量(2.5 ml/kg)患者为大剂量组(25例),不同延长扫描时间和不同扫描剂量肝静脉、肝实质、门静脉强化峰值、平均强化峰值时间与图像质量双盲目测评分值的差异。结果延长扫描时间后,延长组肝静脉、肝实质、门静脉强化峰值、静脉与肝实质差值、图像质量评分为(206.4±3.6)Hu、(110±13)Hu、(188±13)Hu、(74±11)Hu、(3.0±1.2)分,均明显高于对照组,肝实质、门静脉平均强化峰值时间明显低于对照组,2组比较差异具有统计学意义(P<0.05);在延长扫描时间的基础上增大对比剂剂量后,大剂量组上述指标分别为(218±11)Hu、(115±14)Hu、(214±16)Hu、(86±13)Hu、(3.6±0.7)分、(63.8±2.9)s、(44±5)s,均明显优于延长组,2组比较差异具有统计学意义(P<0.05)。结论延长扫描时间(70 s)和增加对比剂剂量(2.5 ml/kg)在一定程度上改善肝硬化患者门静脉期CT图像质量,有利于获取更清晰的CT图像。%Objective To discuss effect of large contrast agent dose and prolonged scanning time on the image quality of CT portal venous phase images in patients with liver cirrhosis. Methods Seventy-five cases of liver cirrho-sis were divided into three groups, which used the conventional time and dose scan (60 s, 1.5 ml/kg) were chosen as control group (25 cases), prolonged scanning time (70 s) and conventional dose scan were as prolonged group (25 cases), high dose (2.5 ml/kg) and prolonged scanning time were as high dose group (25 cases). The

  7. Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer

    Directory of Open Access Journals (Sweden)

    Saima Riaz

    2017-06-01

    Full Text Available Objective(s: Small cell lung cancer (SCLC is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM staging of SCLC, compared to the conventional computed tomography (CT scan and its potential role as a prognosticator.Methods: This retrospective review was conducted on 23 patients, who were histopathologically diagnosed to have SCLC and referred for undergoing 18F-FDG PET/CT scanning during October 2009-December 2015. The rate of agreement between the CT and 18F-FDG PET/CT findings for TNM staging was calculated using the Cohen’s kappa (κ. The median follow-up time was eight months, ranging 27-3 months. The overall and disease-free survival rates were calculated based on the extent of disease.Results: 19 cases were male and four female with the mean age of 58±9 years. The 18F-FDG PET/CT identified limited and extensive diseases in 2 (8.7% and 21 (91.3% patients, respectively. In addition, the results of the Cohen’s kappa demonstrated a strong (κ=0.82, fair (κ=0.24, and poor (κ=0.12 agreement between the PET/CT and CT findings for determining tumor, node, and metastasis stages, respectively. The 18F-FDG PET/CT scans upstaged disease in 47% of the cases with visceral and osseous metastasis. The disease-free survival rates for the limited and extensive diseases were 100% and 23% within the 12-month follow-up. In addition, 8 (35% patients expired during the follow-up period.Conclusion: Improved nodal and metastatic disease identification highlights the role of 18F-FDG PET/CT scanning in initial staging of SCLC with prognostic implications.

  8. Image analysis of the inner ear with CT and MR imaging; Pre-operative assessment for cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Kohzoh; Takeda, Hidehiko; Mutoh, Naoko; Miyakawa, Kohichi (Toranomon Hospital, Tokyo (Japan)); Yukawa, Kumiko; Funasaka, Sohtaro

    1992-06-01

    Recent progress in magnetic resonance imaging (MRI) has made it possible to obtain detailed images of the inner ear by delineating the lymphatic fluid within the labyrinth. We analyzed CT scans and MR imaging in 70 ears manifesting profound deafness owing to inner ear lesions and compared their detective ability for inner ear lesions. The following results were obtained. CT scan examination showed slight to extensive ossification of the labyrinth in six ears (9%), whereas MRI examination revealed low to absent signal intensity of the inner ear in nine ears (13%). Therefore, it was concluded that MRI is more sensitive in detecting abnormalities of the inner ear than CT scan. MRI provided useful information as to whether the cochlear turn is filled with lymphatic fluid or obstructed. This point was one of the greatest advantages of MRI over CT scan. Abnormal findings in either or both the CT scan and the MRI were detected in suppurative labyrinthitis occurring secondary to chronic otitis media, bacterial meningitis and in inner ear trauma. However, such abnormal findings were not detected in patients with idiopathic progressive sensorineural hearing loss, ototoxity or sudden deafness. These findings should be taken into consideration in pre-operative assessment of cochlear implant candidates. (author).

  9. Three dimensional analysis of coelacanth body structure by computer graphics and X-ray CT images

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Naoki (Jikei Univ., Tokyo (Japan). School of Medicine); Hamada, Takashi

    1990-06-01

    Three dimensional imaging processes were applied for the structural and functional analyses of the modern coelacanth (Latimeria chalumnae). Visualization of the obtained images is performed with computer graphics on the basis of serial images by an X-ray CT scanning method. Reconstruction of three dimensional images of the body structure of coelacanth using the volume rendering and surface rendering methods provides us various information about external and internal shapes of this exquisite fish. (author).

  10. Myocardial perfusion imaging with dual energy CT.

    Science.gov (United States)

    Jin, Kwang Nam; De Cecco, Carlo N; Caruso, Damiano; Tesche, Christian; Spandorfer, Adam; Varga-Szemes, Akos; Schoepf, U Joseph

    2016-10-01

    Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  11. SU-E-I-13: Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Kohli, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2015-06-15

    Purpose: A new commercially available metal artifact reduction (MAR) software in computed tomography (CT) imaging was evaluated with phantoms in the presence of metals. The goal was to assess the ability of the software to restore the CT number in the vicinity of the metals without impacting the image quality. Methods: A Catphan 504 was scanned with a GE Optima RT 580 CT scanner (GE Healthcare, Milwaukee, WI) and the images were reconstructed with and without the MAR software. Both datasets were analyzed with Image Owl QA software (Image Owl Inc, Greenwich, NY). CT number sensitometry, MTF, low contrast, uniformity, noise and spatial accuracy were compared for scans with and without MAR software. In addition, an in-house made phantom was scanned with and without a stainless steel insert at three different locations. The accuracy of the CT number and metal insert dimension were investigated as well. Results: Comparisons between scans with and without MAR algorithm on the Catphan phantom demonstrate similar results for image quality. However, noise was slightly higher for the MAR algorithm. Evaluation of the CT number at various locations of the in-house made phantom was also performed. The baseline HU, obtained from the scan without metal insert, was compared to scans with the stainless steel insert at 3 different locations. The HU difference between the baseline scan versus metal scan was improved when the MAR algorithm was applied. In addition, the physical diameter of the stainless steel rod was over-estimated by the MAR algorithm by 0.9 mm. Conclusion: This work indicates with the presence of metal in CT scans, the MAR algorithm is capable of providing a more accurate CT number without compromising the overall image quality. Future work will include the dosimetric impact on the MAR algorithm.

  12. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    Directory of Open Access Journals (Sweden)

    Erdi Yusuf E

    2007-03-01

    Full Text Available Abstract Background It is estimated that 60 million computed tomography (CT scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. Methods The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. Results The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Conclusion Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.

  13. CT myocardial perfusion imaging: current status and future directions.

    Science.gov (United States)

    Williams, M C; Newby, D E

    2016-08-01

    Computed tomography (CT) imaging of the heart has advanced rapidly, and it is now possible to perform a comprehensive assessment at a low radiation dose. CT myocardial perfusion imaging can provide additive information to CT coronary angiography, and is particularly useful in patients with heavily calcified coronary arteries or coronary artery stents. A number of protocols are now available for CT myocardial perfusion including static, dynamic, and dual-energy techniques. This review will discuss the current status of CT myocardial perfusion imaging, its clinical application, and future directions for this technology.

  14. Adherence to follow-up CT scans in patients with small pulmonary nodules, a retrospective study

    DEFF Research Database (Denmark)

    Johansson, Sofie Lock; Gerner Hansen, Niels-Christian

    2010-01-01

    Adherence to follow-up CT scans in patients with small pulmonary nodules, a retrospective study The Danish National guidelines have since 2008 suggested serial follow-up CT scans at 3, 6, 12, and 24 months for nodules between 5 and 10 mm and at 12 and 24 months for nodules less than 5 mm in accor...... is that management of the follow-up of small nodules did improve in 2008-2009, but adherence to the guidelines was still limited. We will now implement a prospective program for monitoring the adherence to the follow-up CTs.......Adherence to follow-up CT scans in patients with small pulmonary nodules, a retrospective study The Danish National guidelines have since 2008 suggested serial follow-up CT scans at 3, 6, 12, and 24 months for nodules between 5 and 10 mm and at 12 and 24 months for nodules less than 5 mm...... in the four year period 2006-2009. In 72 cases, 19 in 2006-2007 and 51 in 2008-2009, one or more small nodules, with diameter ≤ 10 mm, were detected on CT in patients with no known recent malignant disease. For these patients follow-up was suggested, either with CT or PET-CT. One of the 70 patients from 2008...

  15. Potential cancer risk associated to CT scan. State of the art of epidemiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, Marie-Odile; Baysson, Neige Joumy Helene; Jacob, Sophie; Laurier, Dominique [Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses (France). Lab. of Epidemiology

    2013-07-01

    Introduction: The increasing use of computed tomography (CT) scans in paediatric population raises the question of a possible health impact of ionizing radiation exposure associated with CT scans. Material and methods: Two large cohort studies have been recently published that assessed the risk of cancer related to CT examinations of children and young adults. Methodology and results of these studies are presented. Results: The UK cohort included over 176,000 young people, who underwent one or more CT scans between 1985 and 2002. The Australian study compared the risk of cancer and leukaemia in a population of 680,000 young people exposed to CT scans between 1985 and 2005 to non-exposed similar age people. Both studies showed a significant dose-response relation between exposure to CT and leukaemia or brain tumour risks. These results are consistent with predictions from A-bomb survivors' data. However, uncertainties in dosimetric estimation and potential bias linked to underlying medical conditions should be considered. Conclusion and perspectives: Further studies with more accurate dosimetry and assessment of potential bias and uncertainties are needed. Ongoing national studies and the European collaborative EPI-CT study will help to better understand the relation between low level radiation exposure and cancer and to support recommendations for patients'' radiation protection. (orig.)

  16. Lesion Detection in CT Images Using Deep Learning Semantic Segmentation Technique

    Science.gov (United States)

    Kalinovsky, A.; Liauchuk, V.; Tarasau, A.

    2017-05-01

    In this paper, the problem of automatic detection of tuberculosis lesion on 3D lung CT images is considered as a benchmark for testing out algorithms based on a modern concept of Deep Learning. For training and testing of the algorithms a domestic dataset of 338 3D CT scans of tuberculosis patients with manually labelled lesions was used. The algorithms which are based on using Deep Convolutional Networks were implemented and applied in three different ways including slice-wise lesion detection in 2D images using semantic segmentation, slice-wise lesion detection in 2D images using sliding window technique as well as straightforward detection of lesions via semantic segmentation in whole 3D CT scans. The algorithms demonstrate superior performance compared to algorithms based on conventional image analysis methods.

  17. Dose versus image quality in multidetector CT scanning: a methodology for the optimization of acquisition protocols;Dose versus qualite image en TDM multidetecteur: une methodologie pour l'optimisation des protocoles d'acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Bonniaud, G.; Tran Dinh, V.; Texier, N.; Touati, R.; Simon, J.; Roger, P. [Centre Saint Yves, 56 - Vannes (France)

    2009-10-15

    Objective: to determine the influence of acquisition parameters and reconstruction of dose and the image quality in multi detectors T.D.M. for protocols optimization. conclusion: the optimization allowed to reduce in average, the C.T.D.I.vol (weighted computed tomography dose index) of 20% via the pitch increase, the use of a collimation as broad as possible and/or the use of a retrospectively construction (factor zoom and/or increased size of matrix) without degrading the performances of noise and:or resolution of more than 10%. (N.C.)

  18. Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Cunliffe, Alexandra R.; Armato, Samuel G.; White, Bradley; Justusson, Julia [Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637 (United States); Contee, Clay; Malik, Renuka; Al-Hallaq, Hania A., E-mail: hal-hallaq@radonc.uchicago.edu [Department of Radiation and Cellular Oncology, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637 (United States)

    2015-01-15

    Purpose: To characterize the effects of deformable image registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60 Gy, 2 Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pretherapy (4–75 days) CT scan and a treatment planning scan with an associated dose map were collected. To establish correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pretherapy scans then were coregistered with planning scans (and associated dose maps) using the demons deformable registration algorithm and two variants of the Fraunhofer MEVIS algorithm (“Fast” and “EMPIRE10”). Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from each of the three algorithms. The Euclidean distance between manually and automatically mapped landmark points (d{sub E}) and the absolute difference in planned dose (|ΔD|) were calculated. Using regression modeling, |ΔD| was modeled as a function of d{sub E}, dose (D), dose standard deviation (SD{sub dose}) in an eight-pixel neighborhood, and the registration algorithm used. Results: Over 1400 landmark point pairs were identified, with 58–93 (median: 84) points identified per patient. Average |ΔD| across patients was 3.5 Gy (range: 0.9–10.6 Gy). Registration accuracy was highest using the Fraunhofer MEVIS EMPIRE10 algorithm, with an average d{sub E} across patients of 5.2 mm (compared with >7 mm for the other two algorithms). Consequently, average |ΔD| was also lowest using the Fraunhofer MEVIS EMPIRE10 algorithm. |ΔD| increased significantly as a function of d{sub E} (0.42 Gy/mm), D (0.05 Gy/Gy), SD{sub dose} (1.4 Gy/Gy), and the algorithm used (≤1 Gy). Conclusions: An

  19. Cardiac CT for the assessment of chest pain: Imaging techniques and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Hans-Christoph, E-mail: christoph.becker@med.uni-muenchen.de [Ludwig-Maximilians-University, Grosshadern Clinic, Department of Clinical Radiology, Marchioninistr. 15, 81377 Munich (Germany); Johnson, Thorsten [Ludwig-Maximilians-University, Grosshadern Clinic, Department of Clinical Radiology, Marchioninistr. 15, 81377 Munich (Germany)

    2012-12-15

    Immediate and efficient risk stratification and management of patients with acute chest pain in the emergency department is challenging. Traditional management of these patients includes serial ECG, laboratory tests and further on radionuclide perfusion imaging or ECG treadmill testing. Due to the advances of multi-detector CT technology, dedicated coronary CT angiography provides the potential to rapidly and reliably diagnose or exclude acute coronary artery disease. Life-threatening causes of chest pain, such as aortic dissection and pulmonary embolism can simultaneously be assessed with a single scan, sometimes referred to as “triple rule out” scan. With appropriate patient selection, cardiac CT can accurately diagnose heart disease or other sources of chest pain, markedly decrease health care costs, and reliably predict clinical outcomes. This article reviews imaging techniques and clinical results for CT been used to evaluate patients with chest pain entering the emergency department.

  20. Automatic identification of IASLC-defined mediastinal lymph node stations on CT scans using multi-atlas organ segmentation

    Science.gov (United States)

    Hoffman, Joanne; Liu, Jiamin; Turkbey, Evrim; Kim, Lauren; Summers, Ronald M.

    2015-03-01

    Station-labeling of mediastinal lymph nodes is typically performed to identify the location of enlarged nodes for cancer staging. Stations are usually assigned in clinical radiology practice manually by qualitative visual assessment on CT scans, which is time consuming and highly variable. In this paper, we developed a method that automatically recognizes the lymph node stations in thoracic CT scans based on the anatomical organs in the mediastinum. First, the trachea, lungs, and spines are automatically segmented to locate the mediastinum region. Then, eight more anatomical organs are simultaneously identified by multi-atlas segmentation. Finally, with the segmentation of those anatomical organs, we convert the text definitions of the International Association for the Study of Lung Cancer (IASLC) lymph node map into patient-specific color-coded CT image maps. Thus, a lymph node station is automatically assigned to each lymph node. We applied this system to CT scans of 86 patients with 336 mediastinal lymph nodes measuring equal or greater than 10 mm. 84.8% of mediastinal lymph nodes were correctly mapped to their stations.

  1. Texture feature extraction for the lung lesion density classification on computed tomography scan image

    Directory of Open Access Journals (Sweden)

    Hasnely

    2016-05-01

    Full Text Available The radiology examination by computed tomography (CT scan is an early detection of lung cancer to minimize the mortality rate. However, the assessment and diagnosis by an expert are subjective depending on the competence and experience of a radiologist. Hence, a digital image processing of CT scan is necessary as a tool to diagnose the lung cancer. This research proposes a morphological characteristics method for detecting lung cancer lesion density by using the histogram and GLCM (Gray Level Co-occurrence Matrices. The most well-known artificial neural network (ANN architecture that is the multilayers perceptron (MLP, is used in classifying lung cancer lesion density of heterogeneous and homogeneous. Fifty CT scan images of lungs obtained from the Department of Radiology of RSUP Dr. Sardjito Hospital, Yogyakarta are used as the database. The results show that the proposed method achieved the accuracy of 98%, sensitivity of 96%, and specificity of 96%.

  2. Clock Scan Protocol for Image Analysis: ImageJ Plugins.

    Science.gov (United States)

    Dobretsov, Maxim; Petkau, Georg; Hayar, Abdallah; Petkau, Eugen

    2017-06-19

    The clock scan protocol for image analysis is an efficient tool to quantify the average pixel intensity within, at the border, and outside (background) a closed or segmented convex-shaped region of interest, leading to the generation of an averaged integral radial pixel-intensity profile. This protocol was originally developed in 2006, as a visual basic 6 script, but as such, it had limited distribution. To address this problem and to join similar recent efforts by others, we converted the original clock scan protocol code into two Java-based plugins compatible with NIH-sponsored and freely available image analysis programs like ImageJ or Fiji ImageJ. Furthermore, these plugins have several new functions, further expanding the range of capabilities of the original protocol, such as analysis of multiple regions of interest and image stacks. The latter feature of the program is especially useful in applications in which it is important to determine changes related to time and location. Thus, the clock scan analysis of stacks of biological images may potentially be applied to spreading of Na(+) or Ca(++) within a single cell, as well as to the analysis of spreading activity (e.g., Ca(++) waves) in populations of synaptically-connected or gap junction-coupled cells. Here, we describe these new clock scan plugins and show some examples of their applications in image analysis.

  3. A comparative study of SPECT/CT fusion imaging and CT in infiltrated mandible by gingival carcinoma%牙龈癌侵犯下颌骨SPECT/CT融合显像和CT影像的对照研究

    Institute of Scientific and Technical Information of China (English)

    Hongwei Liu; Guichang Li; Ningyi Li; Jie Wang; Baomei Fang

    2009-01-01

    Objective: The aim of the study was to evaluate the clinical value of99mTc-methylene diphosphonic acid (MDP) SPECT/CT fusion imaging and CT scanning in diagnosis of infiltrated mandible by gingival carcinoma. Methods: 18 cases of gingival carcinoma were processed infiltrated mandible by99mTc-MDP SPECT/CT fusion image and CT, and their scanning results compared with pathology findings. Results: Eleven of 13 cases with well-differentiated squamous cell carcinoma showed positive images, one of 11 cases was false positive images by pathology findings, and 10 cases were exhibited infil-trated mandibles; 5 cases with moderately differentiated and poorly differentiated squamous cell carcinoma showed positive images, pathology showed carcinoma cell had infiltrated cavum ossis of mandible. Five of 18 cases were positive images by CT. Conclusion: 99mTc-MDP SPECT/CT fusion imaging is a useful method in diagnosis of infiltrated mandible by gingival carcinoma.

  4. Brain tissue segmentation in PET-CT images using probabilistic atlas and variational Bayes inference.

    Science.gov (United States)

    Xia, Yong; Wang, Jiabin; Eberl, Stefan; Fulham, Michael; Feng, David Dagan

    2011-01-01

    PET-CT provides aligned anatomical (CT) and functional (PET) images in a single scan, and has the potential to improve brain PET image segmentation, which can in turn improve quantitative clinical analyses. We propose a statistical segmentation algorithm that incorporates the prior anatomical knowledge represented by probabilistic brain atlas into the variational Bayes inference to delineate gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF) in brain PET-CT images. Our approach adds an additional novel aspect by allowing voxels to have variable and adaptive prior probabilities of belonging to each class. We compared our algorithm to the segmentation approaches implemented in the expectation maximization segmentation (EMS) and statistical parametric mapping (SPM8) packages in 26 clinical cases. The results show that our algorithm improves the accuracy of brain PET-CT image segmentation.

  5. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  6. Body surface area determined by whole-body CT scanning: need for new formulae?

    DEFF Research Database (Denmark)

    Villa, Chiara; Primeau, Charlotte; Hesse, Ulrik

    2017-01-01

    Calculation of the estimated body surface area (BSA) by body height and weight has been a challenge in the past centuries due to lack of a well-documented gold standard. More recently, available techniques such as 3D laser surface scanning and CT scanning may be expected to quantify the BSA...... Mimics software, and BSA values were automatically extracted from the program. They were compared with nine predictive equations from the literature. Remarkably, close correlations (r > 0·90) were found between BSA values from CT scans and those from the predictive formulae. A mean BSA of the 54 cadavers...

  7. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement

    Directory of Open Access Journals (Sweden)

    Nathaniel H. Greene

    2015-01-01

    Full Text Available Background. Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist. Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter. Methods. This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD on computed tomography (CT to determine loss of resistance depth acquired during epidural placement. Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging. Results. There was a strong association between CT measurement and loss of resistance depth (P35 changed this relationship (P=0.007. The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs>0.9. Conclusions. Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter. Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

  8. Gambaran CT Scan Toraks Sesuai dengan Jenis Sitologi/Histologi pada Pasien Kanker Paru yang Merokok

    Directory of Open Access Journals (Sweden)

    Rosa Tatun

    2016-03-01

    Full Text Available Kanker paru merupakan  penyebab kematian paling banyak akibat keganasan. Kanker paru memberikan gambaran CT scan yang berbeda sesuai dengan jenis sitologi/histologinya. Pemeriksaan CT scan  toraksdengan teknik high resolution computed tomography (HRCT dapat memperlihatkan kelainan kanker parusecara rinci. Penelitian dilakukan di Instalasi Radiologi RSU Persahabatan, Jakarta bekerja sama denganDepartemen Pulmonologi dan Respirasi RSU Persahabatan terhadap 100 sampel yang diperoleh pada bulanNovember 2014 hingga Maret 2015. Berdasarkan jenis sitologi/histologi kanker paru (adenokarsinoma dankarsinoma sel skuamosa/KSS tidak ditemukan  variabel yang bermakna secara statistik  (bentuk, letak, tepispikulasi, tepi lobulasi, nodul satelit. Variabel yang paling banyak ditemukan pada adenokarsinoma maupunKSS adalah bentuk massa, lokasi di sentral dan paru sebelah kanan. Gambaran kanker paru adenokarsinomadan KSS pada pasien merokok paling banyak berupa massa, lokasi di sentral dan lobus kanan paru. Kata kunci: kanker paru, merokok, CT scan toraks   Lung Cancer CT Scan Findings in Smoker Patients Basedon Cytology/Histology Abstract Lung cancer is the leading cause of most deaths due to malignancy. Lung cancer CT scan provides an overview according to the type of cytology / histology. Thorax CT scan with high resolution technique (HRCT may revealdetail lung cancer abnormalities. This study was conducted between Department of Radiology and Departmentof Pulmonology Respiratory, Persahabatan Hospital Jakarta based on 100 samples, November 2014 until March2015. Based on cytological/histological type (adenocarcinoma and squamous cell carcinoma/KSS, it was not found significant meaningfull variables (shape, location, spiculate edge, lobulate edge, satellite nodules. Most commonly variables found in adenocarcinomas and KSS were mass forming, central location, right lung location.Most of adenocarcinoma and SCC in smoked patients were mass forming, central

  9. Cirrhosis: CT and MR imaging evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brancatelli, Giuseppe [Sezione di Radiologia, Ospedale Specializzato in Gastroenterologia, ' Saverio de Bellis' -IRCCS, 70013 Castellana Grotte (Bari) (Italy) and Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy) and Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States)]. E-mail: gbranca@yahoo.com; Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States); Ambrosini, Roberta [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Lagalla, Roberto [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Carriero, Alessandro [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Midiri, Massimo [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Vilgrain, Valerie [Service de Radiologie, Hopital Beaujon, 100 Boulevard du General Leclerc, 92118 Clichy (France)

    2007-01-15

    In this article, we present the CT and MR imaging characteristics of the cirrhotic liver. We describe the altered liver morphology in different forms of viral, alcoholic and autoimmune end-stage liver disease. We present the spectrum of imaging findings in portal hypertension, such as splenomegaly, ascites and varices. We describe the patchy and lacelike patterns of fibrosis, along with the focal confluent form. The process of hepatocarcinogenesis is detailed, from regenerative to dysplastic nodules to overt hepatocellular carcinoma. Different types of non-neoplastic focal liver lesions occurring in the cirrhotic liver are discussed, including arterially enhancing nodules, hemangiomas and peribiliary cysts. We show different conditions causing liver morphology changes that can mimic cirrhosis, such as congenital hepatic fibrosis, 'pseudo-cirrhosis' due to breast metastases treated with chemotherapy, Budd-Chiari syndrome, sarcoidosis and cavernous transformation of the portal vein.

  10. Abdominal wall hernias: imaging with spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G. [Department of Radiology, Bari University Hospital (Italy)

    2000-06-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  11. Semiautomated three-dimensional segmentation software to quantify carpal bone volume changes on wrist CT scans for arthritis assessment.

    Science.gov (United States)

    Duryea, J; Magalnick, M; Alli, S; Yao, L; Wilson, M; Goldbach-Mansky, R

    2008-06-01

    Rapid progression of joint destruction is an indication of poor prognosis in patients with rheumatoid arthritis. Computed tomography (CT) has the potential to serve as a gold standard for joint imaging since it provides high resolution three-dimensional (3D) images of bone structure. The authors have developed a method to quantify erosion volume changes on wrist CT scans. In this article they present a description and validation of the methodology using multiple scans of a hand phantom and five human subjects. An anthropomorphic hand phantom was imaged with a clinical CT scanner at three different orientations separated by a 30-deg angle. A reader used the semiautomated software tool to segment the individual carpal bones of each CT scan. Reproducibility was measured as the root-mean-square standard deviation (RMMSD) and coefficient of variation (CoV) between multiple measurements of the carpal volumes. Longitudinal erosion progression was studied by inserting simulated erosions in a paired second scan. The change in simulated erosion size was calculated by performing 3D image registration and measuring the volume difference between scans in a region adjacent to the simulated erosion. The RMSSD for the total carpal volumes was 21.0 mm3 (CoV = 1.3%) for the phantom, and 44.1 mm3 (CoV = 3.0%) for the in vivo subjects. Using 3D registration and local volume difference calculations, the RMMSD was 1.0-3.0 mm3 The reader time was approximately 5 min per carpal bone. There was excellent agreement between the measured and simulated erosion volumes. The effect of a poorly measured volume for a single erosion is mitigated by the large number of subjects that would comprise a clinical study and that there will be many erosions measured per patient. CT promises to be a quantifiable tool to measure erosion volumes and may serve as a gold standard that can be used in the validation of other modalities such as magnetic resonance imaging.

  12. Three-Dimensions Segmentation of Pulmonary Vascular Trees for Low Dose CT Scans

    Science.gov (United States)

    Lai, Jun; Huang, Ying; Wang, Ying; Wang, Jun

    2016-12-01

    Due to the low contrast and the partial volume effects, providing an accurate and in vivo analysis for pulmonary vascular trees from low dose CT scans is a challenging task. This paper proposes an automatic integration segmentation approach for the vascular trees in low dose CT scans. It consists of the following steps: firstly, lung volumes are acquired by the knowledge based method from the CT scans, and then the data are smoothed by the 3D Gaussian filter; secondly, two or three seeds are gotten by the adaptive 2D segmentation and the maximum area selecting from different position scans; thirdly, each seed as the start voxel is inputted for a quick multi-seeds 3D region growing to get vascular trees; finally, the trees are refined by the smooth filter. Through skeleton analyzing for the vascular trees, the results show that the proposed method can provide much better and lower level vascular branches.

  13. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Paech, Daniel [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany); Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Unterhinninghofen, Roland [Institute of Anthropomatics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kuner, Thomas; Doll, Sara [Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany)

    2017-05-15

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n{sub 1} = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n{sub 2} = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n{sub 3} = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  14. CT scan findings and EEG in systemic lupus erythematodes patients with neuro-psychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Rumiko; Hagiwara, Mariko; Katayose, Keiko; Yashima, Yuko; Kumashiro, Hisashi

    1988-06-01

    In 14 patients with systemic lupus erythematodes presenting with neuro-psychiatric disorders, CT scans were compared with encephalographic (EEG) findings. CT findings were markedly abnormal in 6, slight with a sulcal enlargement in 3, and normal in 5. In the group of markedly abnormal CT findings, focal abnormal low density areas were detected in 2, severe generalized cerebral atrophy in one, and severe atrophy of the right hemisphere in one. EEG findings included focal paroxysmal abnormality of high voltage slow burst at the left frontal dominance and positive spike on the right hemisphere. Epileptic seizure and depressed sensorium seemed to be related to CT abnormality. In 3 patients with epileptic seizures, their symptoms were closely related to CT abnormality. Parkinsonisms and depressed sensorium were also related to CT abnormality. (Namekawa, K).

  15. Evaluation of Radiation Dose Reduction during CT Scans Using Oxide Bismuth and Nano-Barium Sulfate Shields

    CERN Document Server

    Seoung, Youl-Hun

    2015-01-01

    The purpose of the present study was to evaluate radiation dose reduction and image quality during CT scanning by using a new dose reduction fiber sheet (DRFS) with commercially available bismuth shields. These DRFS were composed of nano-barium sulfate (BaSO4), filling the gaps left by the large oxide bismuth (Bi2O3) particle sizes. The radiation dose was measured five times at directionss of 12 o'clock from the center of the polymethyl methacrylate (PMMA) head phantom to calculate an average value using a CT ionization chamber. The image quality measured CT transverse images of the PMMA head phantom depending on X-ray tube voltages and the type of shielding. Two regions of interest in CT transverse images were chosen from the right and left areas under the surface of the PMMA head phantom and from ion chamber holes located at directions of 12 o'clock from the center of the PMMA head phantom. The results of this study showed that the new DRFS shields could reduce dosages to 15.61%, 23.05%, and 22.71% more in ...

  16. Automatic segmentation of lumbar vertebrae in CT images

    Science.gov (United States)

    Kulkarni, Amruta; Raina, Akshita; Sharifi Sarabi, Mona; Ahn, Christine S.; Babayan, Diana; Gaonkar, Bilwaj; Macyszyn, Luke; Raghavendra, Cauligi

    2017-03-01

    Lower back pain is one of the most prevalent disorders in the developed/developing world. However, its etiology is poorly understood and treatment is often determined subjectively. In order to quantitatively study the emergence and evolution of back pain, it is necessary to develop consistently measurable markers for pathology. Imaging based measures offer one solution to this problem. The development of imaging based on quantitative biomarkers for the lower back necessitates automated techniques to acquire this data. While the problem of segmenting lumbar vertebrae has been addressed repeatedly in literature, the associated problem of computing relevant biomarkers on the basis of the segmentation has not been addressed thoroughly. In this paper, we propose a Random-Forest based approach that learns to segment vertebral bodies in CT images followed by a biomarker evaluation framework that extracts vertebral heights and widths from the segmentations obtained. Our dataset consists of 15 CT sagittal scans obtained from General Electric Healthcare. Our main approach is divided into three parts: the first stage is image pre-processing which is used to correct for variations in illumination across all the images followed by preparing the foreground and background objects from images; the next stage is Machine Learning using Random-Forests, which distinguishes the interest-point vectors between foreground or background; and the last step is image post-processing, which is crucial to refine the results of classifier. The Dice coefficient was used as a statistical validation metric to evaluate the performance of our segmentations with an average value of 0.725 for our dataset.

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  19. A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2).

    NARCIS (Netherlands)

    Sierink, J.C.; Saltzherr, T.P.; Beenen, L.F.; Luitse, J.S.; Hollmann, M.W.; Reitsma, J.B.; Edwards, M.J.R.; Hohmann, J.; Beuker, B.J.; Patka, P.; Suliburk, J.W.; Dijkgraaf, M.G.; Goslings, J.C.

    2012-01-01

    BACKGROUND: Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is curr

  20. A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2)

    NARCIS (Netherlands)

    J.C. Sierink (Joanne); T.P. Saltzherr (Teun); L.F.M. Beenen (Ludo); J.S.K. Luitse; M.W. Hollmann (Markus); J.B. Reitsma (Johannes); M.J.R. Edwards (Michael); J. Hohmann (Joachim); B.J.A. Beuker (Benn); P. Patka (Peter); J.W. Suliburk (James); M.G.W. Dijkgraaf (Marcel); J.C. Goslings (Carel)

    2012-01-01

    textabstractBackground: Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its u

  1. Extrapulmonary small cell sarcinoma: involvement of the brain without evidence of extracranial malignancy by serial PET/CT scans

    Directory of Open Access Journals (Sweden)

    Havlioglu Necat

    2008-09-01

    Full Text Available Abstract Background Extrapulmonary small cell carcinoma (EPSCC involving the brain is a rare manifestation of an uncommon tumor type. Case presentation We report a 59 year-old Caucasian female diagnosed with an EPSCC involving the left parietal lobe without detectable extracranial primary tumor followed by serial positron emission tomography/computed tomography (PET/CT imaging. Histopathological examination at both initial presentation and recurrence revealed small cell carcinoma. Serial PET/CT scans of the entire body failed to reveal any extracranial [18F]2-fluoro-2-deoxy-D-glucose (FDG avid lesions at either diagnosis or follow-up. Conclusion Chemotherapy may show a transient response in the treatment of EPSCC. Further studies are needed to help identify optimal treatment strategies. Combination PET/CT technology may be a useful tool to monitor EPSCC and assess for an occult primary malignancy.

  2. Can Spectral CT Imaging Improve the Differentiation between Malignant and Benign Solitary Pulmonary Nodules?

    Science.gov (United States)

    Hua, Xiaolan; Yu, Mingji; Xu, Chengdong; Zhang, Feng; Xu, Jianrong; Wu, Huawei

    2016-01-01

    Purpose To quantitatively assess the value of dual-energy CT (DECT) in differentiating malignancy and benignity of solitary pulmonary nodules. Materials and Methods Sixty-three patients with solitary pulmonary nodules detected by CT plain scan underwent contrast enhanced CT scans in arterial phase (AP) and venous phase (VP) with spectral imaging mode for tumor type differentiation. The Gemstone Spectral Imaging (GSI) viewer was used for image display and data analysis. Region of interest was placed on the relatively homogeneous area of the nodule to measure iodine concentration (IC) on iodine-based material decomposition images and CT numbers on monochromatic image sets to generate spectral HU curve. Normalized IC (NIC), slope of the spectral HU curve (λHU) and net CT number enhancement on 70keV images were calculated. The two-sample t-test was used to compare quantitative parameters. Receiver operating characteristic curves were generated to calculate sensitivity and specificity. Results There were 63 nodules, with 37 malignant nodules (59%) and 26 benign nodules (41%). NIC, λHU and net CT number enhancement on 70keV images for malignant nodules were all greater than those of benign nodules. NIC and λHU had intermediate to high performances to differentiate malignant nodules from benign ones with the areas under curve of 0.89 and 0.86 respectively in AP, 0.96 and 0.89 respectively in VP. Using 0.30 as a threshold value for NIC in VP, one could obtain sensitivity of 93.8% and specificity of 85.7% for differentiating malignant from benign solitary pulmonary nodules. These values were statistically higher than the corresponding values of 74.2% and 53.8% obtained with the conventional CT number enhancement. Conclusions DECT imaging with GSI mode provides more promising value in quantitative way for distinguishing malignant nodules from benign ones than CT enhancement numbers. PMID:26840459

  3. Can Spectral CT Imaging Improve the Differentiation between Malignant and Benign Solitary Pulmonary Nodules?

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    Full Text Available To quantitatively assess the value of dual-energy CT (DECT in differentiating malignancy and benignity of solitary pulmonary nodules.Sixty-three patients with solitary pulmonary nodules detected by CT plain scan underwent contrast enhanced CT scans in arterial phase (AP and venous phase (VP with spectral imaging mode for tumor type differentiation. The Gemstone Spectral Imaging (GSI viewer was used for image display and data analysis. Region of interest was placed on the relatively homogeneous area of the nodule to measure iodine concentration (IC on iodine-based material decomposition images and CT numbers on monochromatic image sets to generate spectral HU curve. Normalized IC (NIC, slope of the spectral HU curve (λHU and net CT number enhancement on 70keV images were calculated. The two-sample t-test was used to compare quantitative parameters. Receiver operating characteristic curves were generated to calculate sensitivity and specificity.There were 63 nodules, with 37 malignant nodules (59% and 26 benign nodules (41%. NIC, λHU and net CT number enhancement on 70keV images for malignant nodules were all greater than those of benign nodules. NIC and λHU had intermediate to high performances to differentiate malignant nodules from benign ones with the areas under curve of 0.89 and 0.86 respectively in AP, 0.96 and 0.89 respectively in VP. Using 0.30 as a threshold value for NIC in VP, one could obtain sensitivity of 93.8% and specificity of 85.7% for differentiating malignant from benign solitary pulmonary nodules. These values were statistically higher than the corresponding values of 74.2% and 53.8% obtained with the conventional CT number enhancement.DECT imaging with GSI mode provides more promising value in quantitative way for distinguishing malignant nodules from benign ones than CT enhancement numbers.

  4. Dynamic CT Scan of the Normal Scapholunate Joint in a Clenched Fist and Radial and Ulnar Deviation.

    Science.gov (United States)

    Kelly, Paul M; Hopkins, John G; Furey, Andrew J; Squire, Daniel S

    2017-08-01

    Injuries to the scapholunate can have severe long-term effects on the wrist. Early detection of these injuries can help identify pathology. The purpose of this study was to evaluate the motions of the scapholunate joint in normal wrists in a clenched fist and through radial and ulnar deviation using novel dynamic computed tomography (CT) imaging. Fifteen participants below 40 years of age consented to have their wrist scanned. Eight participants were randomized to have the right wrist scanned and 7 the left wrist. Volunteers were positioned at the back of the gantry with the wrist placed on the table, palmar side down. Participants began with the hand in a relaxed fist position and then proceeded through an established range of motion protocol. Dynamic CT imaging was captured throughout the range of motion. The movement in the healthy scapholunate joint through a clenched fist and radial and ulnar deviation is minimal. The averages were 1.19, 1.01, and 0.95 mm, representing the middle, dorsal, and volar measurements, respectively. This novel dynamic CT scan of the wrist is a user-friendly way of measuring of the scapholunate distance, which is minimal in the normal wrist below 40 years of age.

  5. Optimized Flat-Detector CT in Stroke Imaging: Ready for First-Line Use?

    Science.gov (United States)

    Eckert, Matthias; Gölitz, Philipp; Lücking, Hannes; Struffert, Tobias; Knossalla, Frauke; Doerfler, Arnd

    2017-01-01

    Using flat-detector CT (FD-CT) for stroke imaging has the advantage that both diagnostic imaging and endovascular therapy can be performed directly within the Angio Suite without any patient transfer and time delay. Thus, stroke management could be speeded up significantly, and patient outcome might be improved. But as precondition for using FD-CT as primary imaging modality, a reliable exclusion of intracranial hemorrhage (ICH) has to be possible. This study aimed to investigate whether optimized native FD-CT, using a newly implemented reconstruction algorithm, may reliably detect ICH in stroke patients. Additionally, the potential to identify ischemic changes was evaluated. Cranial FD-CT scans were obtained in 102 patients presenting with acute ischemic stroke (n = 32), ICH (n = 45) or transient ischemic attack (n = 25). All scans were reconstructed with a newly implemented half-scan cone-beam algorithm. Two experienced neuroradiologists, unaware of clinical findings, evaluated independently the FD-CTs screening for hemorrhage or ischemic signs. The findings were correlated to CT, and rater and inter-rater agreement was assessed. FD-CT demonstrated high sensitivity (95-100%) and specificity (100%) in detecting intracerebral and intraventricular hemorrhage (IVH). Overall, interobserver agreement (κ = 0.92) was almost perfect and rater agreement to CT highly significant (r = 0.81). One infratentorial ICH and 10 or 11 of 22 subarachnoid hemorrhages (SAHs) were missed of whom 7 were perimesencephalic. The sensitivity for detecting acute ischemic signs was poor in blinded readings (0 or 25%, respectively). Optimized FD-CT, using a newly implemented reconstruction algorithm, turned out as a reliable tool for detecting supratentorial ICH and IVH. However, detection of infratentorial ICH and perimesencephalic SAH is limited. The potential of FD-CT in detecting ischemic changes is poor in blinded readings. Thus, plain FD-CT seems insufficient as a standalone modality in

  6. What is a reliable CT scan for diagnosing splenosis under emergency conditions?

    Institute of Scientific and Technical Information of China (English)

    Francesco Giuseppe Garaci; Michele Grande; Massimo Villa; Stefano Mancino; Daniel Konda; Grazia Maria Attinà; Gabriele Galatà; Giovanni Simonetti

    2009-01-01

    Splenosis is a condition in which splenic tissue is present in a non-anatomical position. Implants of splenic tissue can mimic neoplasms and only specific examinations can confirm the correct diagnosis. Here we report a case of a 23-year-old male patient with a history of surgical splenectomy during childhood after trauma. He was admitted to the emergency department with acute bowel obstruction. An abdominalpelvic computed tomography (CT) scan revealed small bowel obstruction and the presence of two rounded, solid masses located in the rectal-vescical pouch. Quantitative analyses of the different density values in the arterial phase and early portal venous phase demonstrated that these lesions were highly vascularised (92 and 97 Hounsfield Units, respectively). The hypothesis of an ectopic splenic mass was made after evaluation of the CT images and clinical history. The acute bowel obstruction caused by adhesive intestinal syndrome was resolved by surgical adhesiolysis. The smallest mass adherent to the rectum was removed. Histopathologic examination confirmed the benign nature of the lesion, which consisted of splenic tissue.

  7. Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans.

    Science.gov (United States)

    Cunliffe, Alexandra R; White, Bradley; Justusson, Julia; Straus, Christopher; Malik, Renuka; Al-Hallaq, Hania A; Armato, Samuel G

    2015-12-01

    We evaluated the image registration accuracy achieved using two deformable registration algorithms when radiation-induced normal tissue changes were present between serial computed tomography (CT) scans. Two thoracic CT scans were collected for each of 24 patients who underwent radiation therapy (RT) treatment for lung cancer, eight of whom experienced radiologically evident normal tissue damage between pre- and post-RT scan acquisition. For each patient, 100 landmark point pairs were manually placed in anatomically corresponding locations between each pre- and post-RT scan. Each post-RT scan was then registered to the pre-RT scan using (1) the Plastimatch demons algorithm and (2) the Fraunhofer MEVIS algorithm. The registration accuracy for each scan pair was evaluated by comparing the distance between landmark points that were manually placed in the post-RT scans and points that were automatically mapped from pre- to post-RT scans using the displacement vector fields output by the two registration algorithms. For both algorithms, the registration accuracy was significantly decreased when normal tissue damage was present in the post-RT scan. Using the Plastimatch algorithm, registration accuracy was 2.4 mm, on average, in the absence of radiation-induced damage and 4.6 mm, on average, in the presence of damage. When the Fraunhofer MEVIS algorithm was instead used, registration errors decreased to 1.3 mm, on average, in the absence of damage and 2.5 mm, on average, when damage was present. This work demonstrated that the presence of lung tissue changes introduced following RT treatment for lung cancer can significantly decrease the registration accuracy achieved using deformable registration.

  8. Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

    CERN Document Server

    Liu, Fenglin; Cong, Wenxiang; Wang, Ge

    2013-01-01

    Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for developing countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The source and detector are translated in opposite directions for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In other words, the popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. Results: The various translational scanning modes are theoretically analyzed, and the scanning parameters are optimized. The numerical simulation results from different numbers of linear scans confirm the feasibility of the proposed scheme, and suggest two pre...

  9. Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, Jessen; Khan, M. Fawad; Maataoui, Adel; Herzog, C.; Vogl, Thomas J. [Johann Wolfgang Goethe University, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Bux, R.; Bratzke, H. [Johann Wolfgang Goethe University, Institute for Forensic Medicine, Frankfurt am Main (Germany); Ackermann, Hanns [Johann Wolfgang Goethe University, Institute for Epidemiology and Medical Statistics, Frankfurt am Main (Germany)

    2005-09-01

    To optimize examination protocols of 16-row multi-detector CT (MDCT) of pelvis for dose reduction with regard to image quality. MDCT of pelvis was performed on 12 cadaver specimens with stepwise reduction of tube current from 160 mA (113, 80, 56, 40, 28) to 20 mA at 120 kV. Scan parameters were 16 x 1.5 mm collimation. Reconstructions of axial and coronal images were used for evaluation of cortex, trabeculum, image quality, image noise, acetabulum and iliosacral (ISJ) joints. After data were blinded, evaluation of images was done by three radiologists according to 5-point Likert scale. Accuracy of the observers in sorting films according to dose reduction was determined with kappa coefficient. Mean values of image evaluation were determined. Pronounced deterioration of image quality for all criteria was observed between 80 and 28 mA. Adequate image quality was obtained at 40 mA [effective dose (E): 2.2 mSv, CTDI{sub w}: 2.8 mGy] for criterion detailed definition of acetabulum and ISJ and at 80 mA (E: 4.4 mSv, CTDI{sub w}: 5.6 mGy) for remaining criteria. Moderate agreement was observed between the three observers (kappa coefficient: 0.31). All observers were excellent in arranging images according to decreasing dose. Using 16-row MDCT image quality of pelvis is acceptable at 80 mA and 120 kV. This translates into a dose reduction of 33% of average value of the nationwide survey of the German Roentgen Society (1999) for this type of examination. (orig.)

  10. Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers

    Energy Technology Data Exchange (ETDEWEB)

    Toftegaard, Jakob, E-mail: jaktofte@rm.dk; Fledelius, Walther; Worm, Esben S.; Poulsen, Per R. [Department of Oncology, Aarhus University Hospital, Aarhus 8000 (Denmark); Seghers, Dieter; Huber, Michael; Brehm, Marcus [Varian Medical Systems, Imaging Laboratory GmbH, Baden-Daettwil 5405 (Switzerland); Elstrøm, Ulrik V. [Department of Medical Physics, Aarhus University Hospital, Aarhus 8000 (Denmark)

    2014-12-15

    Purpose: Implanted gold markers for image-guided radiotherapy lead to streaking artifacts in cone-beam CT (CBCT) scans. Several methods for metal artifact reduction (MAR) have been published, but they all fail in scans with large motion. Here the authors propose and investigate a method for automatic moving metal artifact reduction (MMAR) in CBCT scans with cylindrical gold markers. Methods: The MMAR CBCT reconstruction method has six steps. (1) Automatic segmentation of the cylindrical markers in the CBCT projections. (2) Removal of each marker in the projections by replacing the pixels within a masked area with interpolated values. (3) Reconstruction of a marker-free CBCT volume from the manipulated CBCT projections. (4) Reconstruction of a standard CBCT volume with metal artifacts from the original CBCT projections. (5) Estimation of the three-dimensional (3D) trajectory during CBCT acquisition for each marker based on the segmentation in Step 1, and identification of the smallest ellipsoidal volume that encompasses 95% of the visited 3D positions. (6) Generation of the final MMAR CBCT reconstruction from the marker-free CBCT volume of Step 3 by replacing the voxels in the 95% ellipsoid with the corresponding voxels of the standard CBCT volume of Step 4. The MMAR reconstruction was performed retrospectively using a half-fan CBCT scan for 29 consecutive stereotactic body radiation therapy patients with 2–3 gold markers implanted in the liver. The metal artifacts of the MMAR reconstructions were scored and compared with a standard MAR reconstruction by counting the streaks and by calculating the standard deviation of the Hounsfield units in a region around each marker. Results: The markers were found with the same autosegmentation settings in 27 CBCT scans, while two scans needed slightly changed settings to find all markers automatically in Step 1 of the MMAR method. MMAR resulted in 15 scans with no streaking artifacts, 11 scans with 1–4 streaks, and 3 scans

  11. An approach for quantitative image quality analysis for CT

    Science.gov (United States)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  12. Observation on the Accuracy of Perfusion Imaging and CT Enhanced Scan in Determining Preoperative Grading of Gliomas%灌注成像与CT增强扫描对脑胶质瘤术前分级的判断准确性观察

    Institute of Scientific and Technical Information of China (English)

    杨磊; 杨元山; 张海燕

    2016-01-01

    目的:观察并分析灌注成像与CT增强扫描对脑胶质瘤术前分级的判断准确性。方法对2009年1月至2012年12月来我院就诊并治疗的76例脑胶质瘤患者作回顾性分析,进行灌注扫描与CT增强扫描,以两种诊断方法的影像学资料为基础,灌注成像参考脑血容量(CBV)、脑血流量(CBF)和脑血管表面通透性(PS)和相对脑血容量(rCBV)值进行术前分级, CT增强扫描以影像学图片为判断依据,对比术后病理结果,比较两组术前分级准确率。结果以术后病理结果为标准,灌注成像中,两级别组病灶区域的CBF、PS、CBV、rCBV值均大于对侧正常区域的对应值(P<0.05),高级别组各灌注参数显著大于低级别组对应值(P<0.05)。灌注成像在低级别组、高级别组的判断准确率分别为90.24%、91.43%,均显著高于CT增强扫描的准确率73.17%、71.43%(P<0.05)。结论灌注成像对脑胶质瘤术前分级准确性均高于CT增强扫描,是一种有效的胶质瘤术前诊断技术。%Objective To observe and analyze the accuracy of perfusion imaging and CT scan in determining preoperative grading of gliomas.Methods 76 cases of patients with gliomas who were treated in our hospital between January 2009 and December 2012 were retrospectively analyzed. All underwent perfusion scan and CT enhanced scan. Based on the imaging data of the two kinds of diagnostic methods, preoperative grading of perfusion imaging was performed with reference to cerebral blood volume (CBV), cerebral blood flow (CBF), cerebrovascular permeability surface (PS) and relative cerebral blood volume (rCBV) values.Results The postoperative pathological results were taken as the standard. In terms of perfusion imaging, the values of CBF, PS, CBV and rCBV of lesion areas in the two different grade of groups were greater than the corresponding values of the contralateral normal areas (P<0.05). The perfusion parameters of high grade

  13. Functional CT imaging of angiogenesis in rabbit VX2 soft-tissue tumour

    Science.gov (United States)

    Purdie, Thomas G.; Henderson, Elizabeth; Lee, Ting-Yim

    2001-12-01

    Functional parameters such as blood flow (BF), microvessel permeability surface area product (PS), blood volume (BV) and mean transit time (MTT) are physiological markers related to the changes associated with angiogenesis. In the current study we present a functional CT technique for the simultaneous measurement of these four functional parameters and the display of each parameter as a functional image over an entire tissue slice. New Zealand White rabbits with implanted VX2 thigh tumours were scanned using CT with contrast media injection. The ex vivo method of radioactive microspheres was used to evaluate the accuracy of BF measurements with the functional CT technique. There was a significant linear correlation (R = 0.96) between regional CT and microsphere-measured BF values, with a slope not significantly different from unity (0.98 +/- 0.02, P precision of our CT technique was determined by the repeated scanning under steady-state conditions. The precision of CT-measured BF, PS, BV and MTT was 14%, 18%, 20% and 24%, respectively. In conclusion, BF can be measured accurately and BF, PS, BV and MTT reproducibly using our functional CT technique. Functional CT can be readily incorporated into existing imaging protocols to assess tumour angiogenesis.

  14. Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind

    Energy Technology Data Exchange (ETDEWEB)

    Michel, Morgane; Jacob, Sophie [Institute for Radiological Protection and Nuclear Safety, IRSN/DRPH/SRBE/Laboratoire d' Epidemiologie, BP 17, 92 262 Fontenay-aux-Roses (France); Roger, Gilles [Otolaryngology Department, Trousseau Hospital, Paris (France); Pelosse, Beatrice [Ophthalmology Department, Trousseau Hospital, Paris (France); Laurier, Dominique [Institute for Radiological Protection and Nuclear Safety, IRSN/DRPH/SRBE/Laboratoire d' Epidemiologie, BP 17, 92 262 Fontenay-aux-Roses (France); Le Pointe, Hubert Ducou [Radiology Department, Trousseau Hospital, Paris (France); Bernier, Marie-Odile, E-mail: marie-odile.bernier@irsn.fr [Institute for Radiological Protection and Nuclear Safety, IRSN/DRPH/SRBE/Laboratoire d' Epidemiologie, BP 17, 92 262 Fontenay-aux-Roses (France)

    2012-08-15

    Objectives: The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Methods: Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Results: Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7 mSv and 168 mGy, respectively. Conclusion: A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients' families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT.

  15. Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Mitsuru, E-mail: m2rbimn@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Kawai, Tatsuya; Ito, Masato; Ogawa, Masaki [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Hara, Masaki; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan)

    2012-11-15

    Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 {+-} 15 [SD] and -16 {+-} 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required.

  16. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R.; McNeel, Sandra V. [Environmental Health Investigations Branch, California Department of Public Health, Richmond, CA (United States); Cohen, Ronald A. [Children' s Hospital and Research Center Oakland, Department of Radiology, Oakland, CA (United States)

    2014-05-15

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care. (orig.)

  17. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  18. Potential Lung Nodules Identification for Characterization by Variable Multistep Threshold and Shape Indices from CT Images

    Directory of Open Access Journals (Sweden)

    Saleem Iqbal

    2014-01-01

    Full Text Available Computed tomography (CT is an important imaging modality. Physicians, surgeons, and oncologists prefer CT scan for diagnosis of lung cancer. However, some nodules are missed in CT scan. Computer aided diagnosis methods are useful for radiologists for detection of these nodules and early diagnosis of lung cancer. Early detection of malignant nodule is helpful for treatment. Computer aided diagnosis of lung cancer involves lung segmentation, potential nodules identification, features extraction from the potential nodules, and classification of the nodules. In this paper, we are presenting an automatic method for detection and segmentation of lung nodules from CT scan for subsequent features extraction and classification. Contribution of the work is the detection and segmentation of small sized nodules, low and high contrast nodules, nodules attached with vasculature, nodules attached to pleura membrane, and nodules in close vicinity of the diaphragm and lung wall in one-go. The particular techniques of the method are multistep threshold for the nodule detection and shape index threshold for false positive reduction. We used 60 CT scans of “Lung Image Database Consortium-Image Database Resource Initiative” taken by GE medical systems LightSpeed16 scanner as dataset and correctly detected 92% nodules. The results are reproducible.

  19. Practice of CT scanning;Pratique de la tomodensitometrie

    Energy Technology Data Exchange (ETDEWEB)

    Kerviler, E. de [Assistance Publique - Hopitaux de Paris, Saint Louis, 75 - Paris (France)

    2009-10-15

    The proliferation of CT examinations necessitates the use of indicators of standard dose and reference levels. The dose.length product calculated from the computed tomography dose index (C.T.D.I.) is available on every recent machine and must appeared in the radiological report. Several techniques easily accessible to the console as the dose modulation, allow to reduce the dose to the patient. The combined use of these techniques allows dose reductions of more than 50%. The most important dose reductions are got in the organs with a strong contrast (lungs, sinus of the face). (N.C.)

  20. Automated vertebra identification in CT images

    Science.gov (United States)

    Ehm, Matthias; Klinder, Tobias; Kneser, Reinhard; Lorenz, Cristian

    2009-02-01

    In this paper, we describe and compare methods for automatically identifying individual vertebrae in arbitrary CT images. The identification is an essential precondition for a subsequent model-based segmentation, which is used in a wide field of orthopedic, neurological, and oncological applications, e.g., spinal biopsies or the insertion of pedicle screws. Since adjacent vertebrae show similar characteristics, an automated labeling of the spine column is a very challenging task, especially if no surrounding reference structures can be taken into account. Furthermore, vertebra identification is complicated due to the fact that many images are bounded to a very limited field of view and may contain only few vertebrae. We propose and evaluate two methods for automatically labeling the spine column by evaluating similarities between given models and vertebral objects. In one method, object boundary information is taken into account by applying a Generalized Hough Transform (GHT) for each vertebral object. In the other method, appearance models containing mean gray value information are registered to each vertebral object using cross and local correlation as similarity measures for the optimization function. The GHT is advantageous in terms of computational performance but cuts back concerning the identification rate. A correct labeling of the vertebral column has been successfully performed on 93% of the test set consisting of 63 disparate input images using rigid image registration with local correlation as similarity measure.

  1. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  2. A reassessment of cervical surface anatomy via CT scan in an adult population.

    Science.gov (United States)

    Shen, Xin-Hua; Xue, Hua-Dan; Chen, Yu; Wang, Man; Mirjalili, S Ali; Zhang, Zhu-Hua; Ma, Chao

    2017-04-01

    Surface landmarks in the neck are important for orientations of cervical glands, arteries, veins, nerves, and vertebrae. Recent research suggests some orientations are not correct. What are the cervical landmark orientations in the Chinese population? In this study, two essential cervical anatomy planes, the thyroid cartilage and C7 planes, were assessed in living adult Chinese subjects using computed tomography (CT), and the hyoid, carotid bifurcation, cricoid cartilage, thyroid arteries, and vertebral artery were simultaneously positioned. After excluding patients with distorting pathology, a total of 108 cervical CT scans were examined. The thyroid cartilage plane commonly passed through the C5 (in males) or C4 (in females) vertebral level. The carotid artery bifurcated most commonly at C3 (left) or C4 (right), more than 10 mm above the thyroid cartilage plane bilaterally in most cases. Orientation of the carotid bifurcation according to the body or greater horn of the hyoid was more accurate. The superior thyroid artery was found a finger-breadth below the thyroid cartilage plane, and the inferior thyroid artery in the C7 plane. The inferior border of the cricoid cartilage was most often at C7 (in males) or C6 (in females). The vertebral artery entered the C6 transverse foramen in more than 80% of scans. This reassessment of cervical surface anatomy using modern imaging tools in vivo provides both qualitative and quantitative information for surgeons in clinical practice. Clin. Anat. 30:330-335, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    Science.gov (United States)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  4. CARE kV—智能最佳kV扫描技术——降低剂量的同时提高图像质量%CARE kV-Intelligent Optimal kV Scanning Technology: Reducing X-ray Dose and Improving CT Image Quality Synchronously

    Institute of Scientific and Technical Information of China (English)

    徐卓东

    2012-01-01

    本文介绍了CARE kV-智能最佳kV扫描技术的工作原理和应用意义.作为CT业界唯一地能够根据检查目的和受检者个体情况自动设置最佳kV值的CT扫描技术,CARE kV不但能够最优化CT扫描的个性化辐射剂量水平,降低受检者接受的辐射剂量,而且同时也能够提高CT图像质量.CARE kV的使用还可以减少造影剂使用的总量、浓度和注射速率.%The paper introduced CARE kV-Intelligent optimal kV scanning technology, mainly focusing on its principle and applications. CARE kV is an unique low dose technology that can optimize and patient's customized radiation dose by using optimized kV setting based on CT examination destination and patient's conditions. CARE kV can reduce patient's radiation dose and improve CT image quality synchronously. CARE kV also has positive function of reducing the volume/concentration/injection speed of contrast media during CT contrast examination.

  5. A novel method of estimating effective dose from the point dose method: a case study—parathyroid CT scans

    Science.gov (United States)

    Januzis, Natalie; Nguyen, Giao; Hoang, Jenny K.; Lowry, Carolyn; Yoshizumi, Terry T.

    2015-02-01

    The purpose of this study was to validate a novel approach of applying a partial volume correction factor (PVCF) using a limited number of MOSFET detectors in the effective dose (E) calculation. The results of the proposed PVCF method were compared to the results from both the point dose (PD) method and a commercial CT dose estimation software (CT-Expo). To measure organ doses, an adult female anthropomorphic phantom was loaded with 20 MOSFET detectors and was scanned using the non-contrast and 2 phase contrast-enhanced parathyroid imaging protocols on a 64-slice multi-detector computed tomography scanner. E was computed by three methods: the PD method, the PVCF method, and the CT-Expo method. The E (in mSv) for the PD method, the PVCF method, and CT-Expo method was 2.6  ±  0.2, 1.3  ±  0.1, and 1.1 for the non-contrast scan, 21.9  ±  0.4, 13.9  ±  0.2, and 14.6 for the 1st phase of the contrast-enhanced scan, and 15.5  ±  0.3, 9.8  ±  0.1, and 10.4 for the 2nd phase of the contrast-enhanced scan, respectively. The E with the PD method differed from the PVCF method by 66.7% for the non-contrast scan, by 44.9% and by 45.5% respectively for the 1st and 2nd phases of the contrast-enhanced scan. The E with PVCF was comparable to the results from the CT-Expo method with percent differences of 15.8%, 5.0%, and 6.3% for the non-contrast scan and the 1st and 2nd phases of the contrast-enhanced scan, respectively. To conclude, the PVCF method estimated E within 16% difference as compared to 50-70% in the PD method. In addition, the results demonstrate that E can be estimated accurately from a limited number of detectors.

  6. Noise reduction and vascular enhancement in 4D CT perfusion scans

    NARCIS (Netherlands)

    Mendrik, A.M.

    2010-01-01

    Computed tomography (CT) uses X-ray radiation to construct images. Applying X-ray radiation to the human body may damage the tissue and increases the risk of inducing cancer. Therefore, the radiation dose should be kept as low as reasonably achievable (ALARA). This is especially true for 4D CT perfu

  7. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weidong, E-mail: dongw.z@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Li Chuanxing, E-mail: lichuanh@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Liu Qingyu, E-mail: liu.qingyu@163.com [Department of Radiology, No. 2 Affiliated Hospital, 107 Yanjiangxi Road, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Hu Yingying, E-mail: yingyinghu1981@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Cao Yun, E-mail: caoyun@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Pathology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Huang Jinhua, E-mail: drhuangjh@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China)

    2011-11-15

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  8. A single CdZnTe detector for simultaneous CT/SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Barber, W.C. E-mail: bill@barber.uscf.edu; Iwata, Koji; Hasegawa, B.H.; Bennett, P.R.; Cirignano, L.J.; Shah, K.S

    2003-06-01

    Clinical CT/SPECT systems acquire CT and SPECT data sequentially using different detectors in close proximity to minimise patient movement and interscan delay. We have developed a prototype simultaneous CT/SPECT imager, using a single CdZnTe detector, with the goal of improving image coregistration and decreasing scan time. A 16-pixel CdZnTe detector was operated in pulse-counting mode with 50 ns shaping time. Energy discrimination is used to separate the CT and SPECT data. Simultaneous SPECT and CT images were obtained for a phantom with the X-ray flux limited to reduce pulse pile-up in the radionuclide energy window. At 140 keV, the efficiency and energy resolution are 70% and 10%, respectively, and were constant for fluence rates up to 10{sup 3} cps per detector element for 140 keV gamma rays, but degrade rapidly at higher fluence rates. In pulse-counting mode, the maximum count rate of 10{sup 3} cps per element from the CdZnTe detector is sufficient for SPECT imaging, but is considerably lower than the fluence rates encountered in CT. The smallest lesion visually detectable in SPECT is 9 mm and the CT spatial resolution is smaller than 4.5 mm. Image registration is intrinsic because the data can be acquired simultaneously with a single detector with the same reconstruction geometry.

  9. EFEKTIFITAS VARIASI NILAI WINDOW LEVEL TERHADAP KUALITAS HASIL CT SCAN THORAX LUNG WINDOW

    OpenAIRE

    dani, Rahma

    2014-01-01

    EFEKTIFITAS VARIASI NILAI WINDOW LEVEL TERHADAP KUALITAS HASIL CT SCAN THORAX LUNG WINDOW Rahmadani Jurusan Fisika, FMIPA, Universitas Hasanuddin, Makassar 90245, Indonesia Pembimbing Utama : Prof. Dr. H. Halmar Halide, M.Sc Pembimbing Pertama : Dahlang Tahir, M.Sc. Phd ABSTRAK Telah dilakukan penelitian untuk mengetahui efek variasi nilai window level terhadap kualitas hasil CT Scann thorax lung window dengan pengaturan window width 1000,1500, 2000 dengan varias...

  10. Acute Pyelonephritis Focusing on Perfusion Defects on Contrast Enhansed Computerized Tomography(CT) Scans and Its Clinical Outcome

    Science.gov (United States)

    Ha, Sung-Kyu; Seo, Jung-Kun; Kim, Seung-Jung; Park, Seung-Ho; Park, Chong-Hoon; Lee, Ho-Yung; Han, Dae-Suk; Kim, Ki-Whang

    1997-01-01

    Objectives Many cases of acute pyelonephritis show renal perfusion defects on contrast enhanced computerized tomography (CT) imaging studies. The purpose of this study is to show the frequency of renal perfusion defects in uncomplicated acute pyelonephritis and to compare the clinical responses of patients who had perfusion defects or not. Methods We studied patients who had symptoms and signs of acute pyelonephritis through CT examinations with contrast enhancement. We identified 21 cases who had perfusion defects among 35 patients who had undergone CT imaging studies and compared the clinical data in the two groups of patients who had perfusion defects on CT (group 1) and who had not (group 2). Results Nearly all patients had typical symptoms and signs of acute pyelonephritis such as high fever and chill, flank pain and costovertebral angle tenderness. Combined clinical problems were septic shock (one case, 4.8%) and disseminated intravascular coagulation (DIC) (one case, 4.8%) in group 1. Laboratory findings were not different between the two groups. All patients were treated with antibiotics and had successful recoveries. The duration of recovery of pyuria in group 1 (5.2±9.6 days) was not longer than that in group 2(3.1±2.9 days) (p>0.05). The length of defeverscence in group 1 (7.0±4.6 days) was longer than in group 2 (3.5±2.7 days) (ppyelonephritis patients). We classified CT findings of group 1 as focal unilateral (2 cases, 9.5%), multifocal unilateral (14 cases, 66.7%) and multifocal bilateral (5 cases, 23.8%), and there were no differences between the subgroups of group 1 in the duration of defeverscence. Conclusion Those patients who had perfusion defects on CT showed relatively severe clinical courses but responses to early antibiotics were very good. Contrast enhanced CT scans may be very sensitive for the detection of acute renal parenchymal inflammatory disease and for defining the extent of disease, but it is clinically not essential to perform

  11. Effect of CT scanning parameters on CT number%CT扫描参数对人体组织CT值影响的研究

    Institute of Scientific and Technical Information of China (English)

    彭文献; 彭天舟; 叶小琴; 付益谋; 潘慧平; 高源统; 金光波

    2010-01-01

    目的 探索不同CT扫描参数对人体同一种组织CT值的影响.方法 通过在同一台CT机上,分别改变其中1个扫描参数,如X线管电压、毫安秒和重建函数等,而保持其他扫描参数不变,多次扫描标准体模,测量和分析体模中不同物质的CT值.结果 X线管电压的改变对物质的CT值影响具有显著意义.聚乙烯、聚碳酸酯、有机玻璃的CT值与管电压成正相关;聚四氟乙烯的CT值与管电压成负相关.毫安秒和重建函数对CT值的影响差异无统计学意义.结论 同一个人体组织在不同的X线管电压条件下CT值是变化的.因此,在临床影像诊断和放疗中应该考虑图像扫描参数的设置对诊断和治疗结果的影响.%Objective To study the effects on tissue CT number caused by scan protocols.Methods The phantom was repeatedly scanned in different protocols by changing only one of parameters,such as X-ray tube voltage,mAs and recon kernel,while other parameters were ketp unchanged.The CT number of different materials in phantom were measured and analyzed.Results The CT numbers of tissues changed remarkably with the tube voltage and had different relativity for different tissues.The CT numbers had positive correlation with kV for such maierials as polyethyle,lexan,perspex,but for teflon the correlation was negative.The mAs and recon kernel had no effects on CT number.Conclusions The CT number of tissue changes with scanning X-ray tube voltage,so the setting of scan parameters should be taken into account in image diagnosis and radiotherapy.

  12. Efficacy of CT scanning in a group of 174 patients with orthopedic and musculoskeletal problems

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, H.J.; Hamlin, D.J.; Kiss, S.; Lovelock, J.

    1981-11-01

    One hundred and seventy-four patients with orthopedic and musculoskeletal problems received computed tomography (CT) scans between January 1979 and July 1980. There were 34 trauma patients, 35 patients with known or suspected primary tumors, 20 patients with metastases, 18 patients with suspected spinal stenosis, 25 patients with disc problems, five patients with infections, 13 children with congenital anomalies, and 24 patients with miscellaneous problems. The CT scans proved useful in all the pediatric cases, 97% of the trauma patients, and in the majority of patients with tumors. It appears that absolute indications for CT scanning in orthopedic patients include acute trauma to the spine, pelvis, hip, and shoulder girdles as well as in children with congenital spinal anomalies. Relative indications include determining the extent of the tumor and also aiding in the correct approach for biopsying a lesion.

  13. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi (Kobe Central Municipal Hospital, Kobe (Japan))

    1983-04-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.''

  14. Applications of Micro-CT scanning in medicine and dentistry: Microstructural analyses of a Wistar Rat mandible and a urinary tract stone

    Science.gov (United States)

    Latief, F. D. E.; Sari, D. S.; Fitri, L. A.

    2017-08-01

    High-resolution tomographic imaging by means of x-ray micro-computed tomography (μCT) has been widely utilized for morphological evaluations in dentistry and medicine. The use of μCT follows a standard procedure: image acquisition, reconstruction, processing, evaluation using image analysis, and reporting of results. This paper discusses methods of μCT using a specific scanning device, the Bruker SkyScan 1173 High Energy Micro-CT. We present a description of the general workflow, information on terminology for the measured parameters and corresponding units, and further analyses that can potentially be conducted with this technology. Brief qualitative and quantitative analyses, including basic image processing (VOI selection and thresholding) and measurement of several morphometrical variables (total VOI volume, object volume, percentage of total volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity) were conducted on two samples, the mandible of a wistar rat and a urinary tract stone, to illustrate the abilities of this device and its accompanying software package. The results of these analyses for both samples are reported, along with a discussion of the types of analyses that are possible using digital images obtained with a μCT scanning device, paying particular attention to non-diagnostic ex vivo research applications.

  15. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants.

    Science.gov (United States)

    Castro, Alfonso; Rey, Alberto; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium).

  16. Automated segmentation of the thyroid gland on thoracic CT scans by multiatlas label fusion and random forest classification.

    Science.gov (United States)

    Narayanan, Divya; Liu, Jiamin; Kim, Lauren; Chang, Kevin W; Lu, Le; Yao, Jianhua; Turkbey, Evrim B; Summers, Ronald M

    2015-10-01

    The thyroid is an endocrine gland that regulates metabolism. Thyroid image analysis plays an important role in both diagnostic radiology and radiation oncology treatment planning. Low tissue contrast of the thyroid relative to surrounding anatomic structures makes manual segmentation of this organ challenging. This work proposes a fully automated system for thyroid segmentation on CT imaging. Following initial thyroid segmentation with multiatlas joint label fusion, a random forest (RF) algorithm was applied. Multiatlas label fusion transfers labels from labeled atlases and warps them to target images using deformable registration. A consensus atlas solution was formed based on optimal weighting of atlases and similarity to a given target image. Following the initial segmentation, a trained RF classifier employed voxel scanning to assign class-conditional probabilities to the voxels in the target image. Thyroid voxels were categorized with positive labels and nonthyroid voxels were categorized with negative labels. Our method was evaluated on CT scans from 66 patients, 6 of which served as atlases for multiatlas label fusion. The system with independent multiatlas label fusion method and RF classifier achieved average dice similarity coefficients of [Formula: see text] and [Formula: see text], respectively. The system with sequential multiatlas label fusion followed by RF correction increased the dice similarity coefficient to [Formula: see text] and improved the segmentation accuracy.

  17. Point spread function modeling and images restoration for cone-beam CT

    CERN Document Server

    Zhang, Hua; Shi, Yikai; Xu, Zhe

    2014-01-01

    X-ray cone-beam computed tomography (CT) has the notable features such as high efficiency and precision, and is widely used in the fields of medical imaging and industrial non-destructive testing, but the inherent imaging degradation reduces the quality of CT images. Aimed at the problems of projection images degradation and restoration in cone-beam CT, a point spread function (PSF) modeling method is proposed firstly. The general PSF model of cone-beam CT is established, and based on it, the PSF under arbitrary scanning conditions can be calculated directly for projection images restoration without the additional measurement, which greatly improved the application convenience of cone-beam CT. Secondly, a projection images restoration algorithm based on pre-filtering and pre-segmentation is proposed, which can make the edge contours in projection images and slice images clearer after restoration, and control the noise in the equivalent level to the original images. Finally, the experiments verified the feasib...

  18. A CAD of fully automated colonic polyp detection for contrasted and non-contrasted CT scans.

    Science.gov (United States)

    Tulum, Gökalp; Bolat, Bülent; Osman, Onur

    2017-04-01

    Computer-aided detection (CAD) systems are developed to help radiologists detect colonic polyps over CT scans. It is possible to reduce the detection time and increase the detection accuracy rates by using CAD systems. In this paper, we aimed to develop a fully integrated CAD system for automated detection of polyps that yields a high polyp detection rate with a reasonable number of false positives. The proposed CAD system is a multistage implementation whose main components are: automatic colon segmentation, candidate detection, feature extraction and classification. The first element of the algorithm includes a discrete segmentation for both air and fluid regions. Colon-air regions were determined based on adaptive thresholding, and the volume/length measure was used to detect air regions. To extract the colon-fluid regions, a rule-based connectivity test was used to detect the regions belong to the colon. Potential polyp candidates were detected based on the 3D Laplacian of Gaussian filter. The geometrical features were used to reduce false-positive detections. A 2D projection image was generated to extract discriminative features as the inputs of an artificial neural network classifier. Our CAD system performs at 100% sensitivity for polyps larger than 9 mm, 95.83% sensitivity for polyps 6-10 mm and 85.71% sensitivity for polyps smaller than 6 mm with 5.3 false positives per dataset. Also, clinically relevant polyps ([Formula: see text]6 mm) were identified with 96.67% sensitivity at 1.12 FP/dataset. To the best of our knowledge, the novel polyp candidate detection system which determines polyp candidates with LoG filters is one of the main contributions. We also propose a new 2D projection image calculation scheme to determine the distinctive features. We believe that our CAD system is highly effective for assisting radiologist interpreting CT.

  19. Relationship between lower third molar and mandibular canal; Preoperative evaluation using CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Itou, Masaki; Miyagishima, Toshio; Onizuka, Hiroyuki (Fujieda City Shida General Hospital, Shizuoka (Japan)); Takagi, Norio

    1994-01-01

    The mandibular canal is often closely related to the lower third molars. During the surgical removal of the third molar, the inferior alveolar nerve in the canal is sometimes damaged leading to impaired sensation in the lower lip. This is one of the most unpleasant postoperative complications. The buccolingual relationship between the lower third molar and the mandibular canal cannot be diagnosed by ortho-pantomography although preoperative evaluation must be carried out radiologically. In present study, the relationship was determined by using CT scan. Forty-seven lower third molars of 35 patients were evaluated preoperatively by CT scan. The mandibular canal of all cases overlapped with the third molar on ortho-pantomography. CT scan was taken in two ways. The first was the Tragion-Menton plane which was nearly parallel to the canal at the apex of the third molar. The second was the plane of the axis of the third molar. Axial CT scan was taken when the third molar erupted horizontally, and coronal CT scan was done when the molar erupted vertically. CT scan examination exactly revealed the position of the mandibular canal in relation to the root of the third molar. The canal was located buccally to the roots in 55 percent of cases, apicobuccally in 6 percent, apically in 23 percent, apicolingually in 6 percent, lingually in 2 percent, and between roots in 6 percent. The results of the present study were consistent with previous reports. In 12 cases, the inferior alveolar neurovascular bundle was visible during operation. It was visible in only 2 of 22 cases when the canal was located buccally. It was visible, on the other hand, in all cases in which the canal was located apicolingually, lingually, and between roots. It also tended to be visible when the canal overlapped more strongly with the third molar on preoperative ortho-pantomography. (author).

  20. Initial brain CT scan and shunting outcomes in children with hydrocephalus

    Directory of Open Access Journals (Sweden)

    Andi Anita Utami

    2013-04-01

    Full Text Available Background Hydrocephalus is one of the most common clinical conditions affecting the central nervous system, with a congenital hydrocephalus incidence of 3-4 per 1000 births. Incidence of acquired types of hydrocephalus is unknown. Brain computerised tomography (CT scan can be used to assess the size of ventricles and other structures. Shunting has long been performed to alleviate hydrocephalus. Shunting has dramatically changed the outlook of children with hydrocephalus, with many of them having normal life expectancies and attaining normal intelligence. Objective To determine the outcomes of shunting in children with hydrocephalus based on initial brain CT scan. Methods We performed a cross-sectional study in Dr. Kariadi Hospital. Initial brain CT scan data were collected from the medical records of children admitted to the Neurosurgery Ward for ventriculoperitoneal (VP shunt surgery from January 2009 to December 2010. We studied the brain CT scan findings before VP shunt surgery and the outcomes of the children after VP shunt surgery. Radiological findings were determined by a radiologist responsible at that time. Results This study consisted of 30 subjects, 19 boys and 11 girls. Initial brain CT scans to assess disease severity revealed the following conditions: lateral ventricle dilatation in 7 subjects, lateral and third ventricle dilatation in 16 subjects, and lateral, third and fourth ventricle dilatation in 7 subjects. After VP shunt surgery, 3 subjects in the lateral, third and fourth ventricle dilatation category died. They were grouped according to their condition. Group 1 consisted of subjects with only lateral ventricle dilatation and subjects with lateral and third ventricle dilatation (23 subjects, while group 2 consisted of subjects with lateral, third and fourth ventricle dilatation (7 subjects. More survivors were found in group 1 than those in group 2. Conclusion Less severe initial brain CT scan findings are associated with

  1. Body surface area determined by whole-body CT scanning: need for new formulae?

    Science.gov (United States)

    Villa, Chiara; Primeau, Charlotte; Hesse, Ulrik; Hougen, Hans Petter; Lynnerup, Niels; Hesse, Birger

    2017-03-01

    Calculation of the estimated body surface area (BSA) by body height and weight has been a challenge in the past centuries due to lack of a well-documented gold standard. More recently, available techniques such as 3D laser surface scanning and CT scanning may be expected to quantify the BSA in an easier and more accurate way. This study provides the first comparison between BSA obtained from post-mortem whole-body CT scans and BSA calculated by nine predictive formulae. The sample consisted of 54 male cadavers ranging from 20 to 87 years old. 3D reconstructions were generated from CT scans using Mimics software, and BSA values were automatically extracted from the program. They were compared with nine predictive equations from the literature. Remarkably, close correlations (r > 0·90) were found between BSA values from CT scans and those from the predictive formulae. A mean BSA of the 54 cadavers of 1·84-1·87 m(2) was calculated by all formulae except one, SD values varying between 0·171 and 0·223 m(2) . T-tests revealed significant differences between mean BSA values calculated with CT and three of the formulae. Regression analyses showed intercepts >(0;0) and slopes <1·0 using all predictive equations, with the CT scan determination as gold standard. It is concluded that DuBois and DuBois' equation can be safely used in normal-weight male subjects with high accuracy, but it seems likely that BSA is underestimated in underweight subjects and overestimated in overweight individuals. Creation of new formulae specific for overweight subjects and children may be needed.

  2. CT scan findings of fungal pneumonia; Diagnose der Pilzpneumonie in der Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Heckmann, M.; Uder, M.; Bautz, W.; Heinrich, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Diagnostische Radiologie

    2008-07-01

    The importance of fungal infection of the lung in immunocompromised patients has increased substantially during the last decades. Numerically the most patients are those with neutropenia, e.g. patients with malignancies or solid organ and stem cell transplantation, chemotherapy, corticosteroid use and HIV infection. Although fungal infections can occur in immunocompetent patients, their frequency in this population is rare. The clinical symptoms such as fever accompanied with non-productive cough are unspecific. In some patients progression to hypoxemia and dyspnea may occur rapidly. In spite of improved antifungal therapy morbidity and mortality of these infections are still high. Therefore an early and non-invasive diagnosis is very important. That is why CT and even better High-Resolution-CT (HR-CT) is a very important modality in examining immunocompromised patients with a probability of fungal infection. CT is everywhere available and, as a non-invasive method, able to give the relevant diagnose efficiently. This paper should give an overview about the radiologic findings and possible differential diagnosis of diverse pulmonary fungal infections in CT. Pneumonias caused by Aspergillus, Cryptococcus, Candida, Histoplasma, Mucor and Geotrichum capitatum are illustrated. (orig.)

  3. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  4. Proton-induced x-ray fluorescence CT imaging.

    Science.gov (United States)

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Matsuo, Yuto; Fahrig, Rebecca; Shirato, Hiroki; Umegaki, Kikuo; Xing, Lei

    2015-02-01

    To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulatio