  1. Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Weiwei; Du, Xiangke [Peking University People' s Hospital, Beijing (China); Li, Jianying [GE Healthcare China, Beijing (China)

    2009-12-15

    To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans. This formula was used to predict the required tube current to obtain the desired cardiac CT image noise based on the timing bolus noise measurement. Subsequently, 80 additional cardiac patients (Group B) were scanned with individually adjusted tube currents using an established formula to evaluate its ability to obtain accurate and consistent image noise across the patient population. Image quality was evaluated using score scale of 1 to 5 with a score of 3 or higher being clinically acceptable. Using the formula, we obtained an average CT image noise of 28.55 Hounsfield unit (HU), with a standard deviation of only 1.7 HU, as opposed to a target value of 28 HU. Image quality scores were 4.03 and 4.27 for images in Groups A and B, respectively, and there was no statistical difference between the image quality scores between the two groups. However, the average CT dose index (CTDIvol) was 30% lower for Group B. Adjusting the tube current based on timing bolus scans may provide a consistent image quality and dose optimization for cardiac patients of various body mass index values.

  2. Automated Detection of Healthy and Diseased Aortae from Images Obtained by Contrast-Enhanced CT Scan

    Directory of Open Access Journals (Sweden)

    Michael Gayhart

    2013-01-01

    Full Text Available Purpose. We developed the next stage of our computer assisted diagnosis (CAD system to aid radiologists in evaluating CT images for aortic disease by removing innocuous images and highlighting signs of aortic disease. Materials and Methods. Segmented data of patient’s contrast-enhanced CT scan was analyzed for aortic dissection and penetrating aortic ulcer (PAU. Aortic dissection was detected by checking for an abnormal shape of the aorta using edge oriented methods. PAU was recognized through abnormally high intensities with interest point operators. Results. The aortic dissection detection process had a sensitivity of 0.8218 and a specificity of 0.9907. The PAU detection process scored a sensitivity of 0.7587 and a specificity of 0.9700. Conclusion. The aortic dissection detection process and the PAU detection process were successful in removing innocuous images, but additional methods are necessary for improving recognition of images with aortic disease.

  3. Furthering Chemical and Geophysical Computations: Analysis of SACROC SEM and CT images to obtain pore percentage, size, and connectivity data

    Science.gov (United States)

    Mur, A. J.; Purcell, C. C.; Harbert, W. P.; Soong, Y.; Kutchko, B. G.; Kennedy, S.; McIntryre, D.

    2009-12-01

    The National Energy Technology Laboratory of the United States Department of Energy, in collaboration with the Bureau of Economic Geology in Austin, Texas has been involved in an extensive study of the many aspects involved in the injection of CO2 into the 2042 meter deep Permian reef structure at the SACROC field. Subsamples of reef limestone cores used for seismic velocity measurements were obtained. XRD determined the sample to be ~99% Calcite and ~1% Dolomite with a small amount of impurities. Preliminary petrographic slides revealed a vuggy porosity. We acquired CT scans of a SACROC limestone core at the Morgantown NETL site. We also acquired a high pixel resolution (112 MB) SEM secondary electron image of the reef limestone at RJ Lee Group. By using ArcMap , we created a tool that groups grayscale ranges into three categories, cleans boundaries between groups, and produces a polygon map of the macropores, micropores, and matrix. The darkest areas in the SEM image were cavern-like pores and were thus called macropores. Micropores, the brightest regions, are textured micrite faces that create many, small pore spaces. Using ImageJ, the CT and Arc pore maps were analyzed to reveal pore shape statistics. Average pore perimeter, average pore area, and pore connectivity is essential for chemistry experiments that will emulate time exposure of CO2 to limestone. Further, ImageJ allows us to obtain pore orientation information. This is important in understanding the anisotropic conditions that may or may not affect seismic data. The image is 10240x11264 pixels which correspond to ~ 8890.00x9780.00 micrometers. Micro- and macropores combined, there were 613744 pores mapped. Differing statistical methods revealed differing results. For example, the average pore perimeter was ~28 microns while the average pore area was perimeter. The lower estimate was formulated by using the maximum pore perimeter as the average pore size. By using the 13% porosity model and assuming

  4. [Minimum intensity projection image and curved reformation image of the main pancreatic duct obtained by helical CT in patients with main pancreatic duct dilation].

    Science.gov (United States)

    Takeshita, K; Furui, S; Yamauchi, T; Harasawa, A; Kohtake, H; Sasaki, Y; Suzuki, S; Tanaka, H; Takeshita, T

    1999-03-01

    Contrast enhanced CT was performed in seven patients with pancreatic disease (chronic pancreatitis, n = 3; pancreatic head cancer, n = 2; mucin-producing pancreatic tumor, n = 2) who showed dilation of the main pancreatic duct (MPD) Minimum intensity projection (Min-IP) images of the pancreas were obtained using multi-projection volume reconstruction (MPVR) software by selecting an oblique slab that contained the entire MPD. Curved reformation (CR) images were obtained using multiplanar reformation (MPR) software by tracing the MPD on the Min-IP image. Both Min-IP images and CR images clearly showed the dilated main pancreatic duct in all seven patients. In three of the seven, obstruction of the MPD in the pancreatic head and the cause of obstruction (tumor mass, n = 2; caliculus, n = 1) were also clearly seen. Min-IP and CR images seem to be useful for the diagnosis of pancreatic diseases.

  5. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Directory of Open Access Journals (Sweden)

    Paoli Alessandro

    2011-02-01

    Full Text Available Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast and preoperative (radiographic template models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology.

  6. Validity of Fusion Imaging of Hamster Heart obtained by Fluorescent and Phase-Contrast X-Ray CT with Synchrotron Radiation

    Science.gov (United States)

    Wu, J.; Takeda, T.; Lwin, Thet Thet; Huo, Q.; Sunaguchi, N.; Murakami, T.; Mouri, S.; Nasukawa, S.; Fukami, T.; Yuasa, T.; Hyodo, K.; Hontani, H.; Minami, M.; Akatsuka, T.

    2007-01-01

    Fluorescent X-ray CT (FXCT) to depict functional information and phase-contrast X-ray CT (PCCT) to demonstrate morphological information are being developed to analyze the disease model of small animal. To understand the detailed pathological state, integration of both functional and morphological image is very useful. The feasibility of image fusion between FXCT and PCCT were examined by using ex-vivo hearts injected fatty acid metabolic agent (127I-BMIPP) in normal and cardiomyopathic hamsters. Fusion images were reconstructed from each 3D image of FXCT and PCCT. 127I-BMIPP distribution within the heart was clearly demonstrated by FXCT with 0.25 mm spatial resolution. The detailed morphological image was obtained by PCCT at about 0.03 mm spatial resolution. Using image integration technique, metabolic abnormality of fatty acid in cardiomyopathic myocardium was easily recognized corresponding to anatomical structures. Our study suggests that image fusion provides important biomedical information even in FXCT and PCCT imaging.

  7. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    OpenAIRE

    Paoli Alessandro; Barone Sandro; Chessa Giacomo; Frisardi Gianni; Razionale Armando; Frisardi Flavio

    2011-01-01

    Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgi...

  8. Comparison of cerebral blood flow data obtained by computed tomography (CT) perfusion with that obtained by xenon CT using 320-row CT.

    Science.gov (United States)

    Takahashi, Satoshi; Tanizaki, Yoshio; Kimura, Hiroaki; Akaji, Kazunori; Kano, Tadashige; Suzuki, Kentaro; Takayama, Youhei; Kanzawa, Takao; Shidoh, Satoka; Nakazawa, Masaki; Yoshida, Kazunari; Mihara, Ban

    2015-03-01

    Cerebral blood flow (CBF) data obtained by computed tomography perfusion (CTP) imaging have been shown to be qualitative data rather than quantitative, in contrast with data obtained by other imaging methods, such as xenon CT (XeCT) imaging. Thus, interpatient comparisons of CBF values themselves obtained by CTP may be inaccurate. In this study, we have compared CBF ratios as well as CBF values obtained from CTP-CBF data to those obtained from XeCT-CBF data for the same patients to determine CTP-CBF parameters that can be used for interpatient comparisons. The data used in the present study were obtained as volume data using 320-row CT. The volume data were applied to an automated region of interest-determining software (3DSRT, version 3.5.2 ) and converted to 59 slices of 2 mm interval standardized images. In the present study, we reviewed 10 patients with occlusive cerebrovascular diseases (CVDs) undergoing both CTP and XeCT in the same period. Our study shows that ratios of CBF measurements, such as hemodynamic stress distribution (perforator-to-cortical flow ratio of middle cerebral artery [MCA] region) or the left/right ratio for the region of the MCA, calculated using CTP data have been shown to correlate well with the same ratios calculated using XeCT data. These results suggest that such CBF ratios could be useful for generating interpatient comparisons of CTP-CBF data obtained by 320-row CT among patients with occlusive CVD.

  9. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  10. A sparsity-based iterative algorithm for reconstruction of micro-CT images from highly undersampled projection datasets obtained with a synchrotron X-ray source

    Science.gov (United States)

    Melli, S. Ali; Wahid, Khan A.; Babyn, Paul; Cooper, David M. L.; Gopi, Varun P.

    2016-12-01

    Synchrotron X-ray Micro Computed Tomography (Micro-CT) is an imaging technique which is increasingly used for non-invasive in vivo preclinical imaging. However, it often requires a large number of projections from many different angles to reconstruct high-quality images leading to significantly high radiation doses and long scan times. To utilize this imaging technique further for in vivo imaging, we need to design reconstruction algorithms that reduce the radiation dose and scan time without reduction of reconstructed image quality. This research is focused on using a combination of gradient-based Douglas-Rachford splitting and discrete wavelet packet shrinkage image denoising methods to design an algorithm for reconstruction of large-scale reduced-view synchrotron Micro-CT images with acceptable quality metrics. These quality metrics are computed by comparing the reconstructed images with a high-dose reference image reconstructed from 1800 equally spaced projections spanning 180°. Visual and quantitative-based performance assessment of a synthetic head phantom and a femoral cortical bone sample imaged in the biomedical imaging and therapy bending magnet beamline at the Canadian Light Source demonstrates that the proposed algorithm is superior to the existing reconstruction algorithms. Using the proposed reconstruction algorithm to reduce the number of projections in synchrotron Micro-CT is an effective way to reduce the overall radiation dose and scan time which improves in vivo imaging protocols.

  11. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  12. Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake, E-mail: yamada@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Jinzaki, Masahiro, E-mail: jinzaki@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Hosokawa, Takahiro, E-mail: snowglobe@infoseek.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Tanami, Yutaka, E-mail: tanami@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Abe, Takayuki, E-mail: tabe@z5.keio.jp [Center for Clinical Research, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Kuribayashi, Sachio, E-mail: skuribay@med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan)

    2014-10-15

    Highlights: • We compared virtual monochromatic spectral (VMS) images with 120-kVp images. • VMS images are generated using accurate two-material beam-hardening correction. • Abdominal 70-keV VMS images provide better image quality than 120-kVp images. • Iterative reconstruction can further improve the image quality of VMS images. - Abstract: Objectives: To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. Materials and methods: Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. Results: VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P < 0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P < 0.004). Conclusions: VMS

  13. CT image of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Morioka, Nobuo; Shudo, Yuji; Jahana, Masanobu; Matsuki, Tsutomu; Kotani, Kazuhiko (Tottori Univ., Yonago (Japan). School of Medicine)

    1983-10-01

    Computor tomographic images of 11 patients who had had thymectomy for myasthenia gravis or thymoma were studied retrospectively. Of those 11 patients, malignant thymoma and benign condition including normal thymus were 6 and 5 respectively. On CT, calcification and lobulation with irregular margin seem to be reliable findings of malignancy. Defect or abscence of fatty plane and non-homogenous density are ancillary.

  14. Dynamic CT myocardial perfusion imaging.

    Science.gov (United States)

    Caruso, Damiano; Eid, Marwen; Schoepf, U Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie; Spandorfer, Adam; Laghi, Andrea; De Cecco, Carlo N

    2016-10-01

    Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  15. CT Imaging: Basics and New Trends

    Science.gov (United States)

    Peyrin, Françoise; Engelke, Klaus

    This chapter presents the principle of X-ray CT and its evolution during the last 40 years. The first section describes the physical basis of X-ray CT, tomographic image reconstruction algorithms, and the source of artifacts in X-ray CT images. The second section is devoted to the evolution of CT technology from the first translation-rotation systems to multi-slice spiral CTs currently used today. The next section addresses specific developments of CT technology and applications, like perfusion CT, quantitative CT, and spectral CT. The fourth section introduces the problem of radiation exposure delivered to the patient and its evaluation. Finally the last section addresses the development in micro- and even nano-CT which is a rapidly evolving area in preclinical imaging and biology.

  16. Denoising CT Images using wavelet transform

    Directory of Open Access Journals (Sweden)

    Lubna Gabralla

    2015-05-01

    Full Text Available Image denoising is one of the most significant tasks especially in medical image processing, where the original images are of poor quality due the noises and artifacts introduces by the acquisition systems. In this paper, we propose a new image denoising scheme by modifying the wavelet coefficients using soft-thresholding method, we present a comparative study of different wavelet denoising techniques for CT images and we discuss the obtained results. The denoising process rejects noise by thresholding in the wavelet domain. The performance is evaluated using Peak Signal-to-Noise Ratio (PSNR and Mean Squared Error (MSE. Finally, Gaussian filter provides better PSNR and lower MSE values. Hence, we conclude that this filter is an efficient one for preprocessing medical images.

  17. Calibration free beam hardening correction for cardiac CT perfusion imaging

    Science.gov (United States)

    Levi, Jacob; Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    Myocardial perfusion imaging using CT (MPI-CT) and coronary CTA have the potential to make CT an ideal noninvasive gate-keeper for invasive coronary angiography. However, beam hardening artifacts (BHA) prevent accurate blood flow calculation in MPI-CT. BH Correction (BHC) methods require either energy-sensitive CT, not widely available, or typically a calibration-based method. We developed a calibration-free, automatic BHC (ABHC) method suitable for MPI-CT. The algorithm works with any BHC method and iteratively determines model parameters using proposed BHA-specific cost function. In this work, we use the polynomial BHC extended to three materials. The image is segmented into soft tissue, bone, and iodine images, based on mean HU and temporal enhancement. Forward projections of bone and iodine images are obtained, and in each iteration polynomial correction is applied. Corrections are then back projected and combined to obtain the current iteration's BHC image. This process is iterated until cost is minimized. We evaluate the algorithm on simulated and physical phantom images and on preclinical MPI-CT data. The scans were obtained on a prototype spectral detector CT (SDCT) scanner (Philips Healthcare). Mono-energetic reconstructed images were used as the reference. In the simulated phantom, BH streak artifacts were reduced from 12+/-2HU to 1+/-1HU and cupping was reduced by 81%. Similarly, in physical phantom, BH streak artifacts were reduced from 48+/-6HU to 1+/-5HU and cupping was reduced by 86%. In preclinical MPI-CT images, BHA was reduced from 28+/-6 HU to less than 4+/-4HU at peak enhancement. Results suggest that the algorithm can be used to reduce BHA in conventional CT and improve MPI-CT accuracy.

  18. Dose calculation based on Cone Beam CT images

    DEFF Research Database (Denmark)

    Slot Thing, Rune

    , several other factors contributing to the image quality degradation, and while one should, theoretically, be able to obtain CT-like image quality from CBCT scans, clinical image quality is often very far from this ideal realisation. The present thesis describes the investigation of potential image quality...... improvements in clinical CBCT imaging achieved through post-processing of the clinical image data. A Monte Carlo model was established to predict patient specific scattered radiation in CBCT imaging, based on anatomical information from the planning CT scan. This allowed the time consuming Monte Carlo......Cone beam CT (CBCT) imaging is frequently used in modern radiotherapy to ensure the proper positioning of the patient prior to each treatment fraction. With the increasing use of CBCT imaging for image guidance, interest has grown in exploring the potential use of these 3– or 4–D medical images...

  19. Hepatic CT image query using Gabor features

    Institute of Scientific and Technical Information of China (English)

    Chenguang Zhao(赵晨光); Hongyan Cheng(程红岩); Tiange Zhuang(庄天戈)

    2004-01-01

    A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented.For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transform is utilized to analyze the texture of the pathology bearing region and extract the corresponding feature vectors. For a given sample image, we compare its feature vector with those of other images. Similar images with the highest rank are retrieved. In experiments, 45 liver CT images are collected, and the effectiveness of Gabor texture for content based retrieval is verified.

  20. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin;

    2012-01-01

    on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...... inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant......This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...

  1. Image reconstruction for brain CT slices

    Institute of Scientific and Technical Information of China (English)

    吴建明; 施鹏飞

    2004-01-01

    Different modalities in biomedical images, like CT, MRI and PET scanners, provide detailed cross-sectional views of human anatomy. This paper introduces three-dimensional brain reconstruction based on CT slices. It contains filtering, fuzzy segmentation, matching method of contours, cell array structure and image animation. Experimental results have shown its validity. The innovation is matching method of contours and fuzzy segmentation algorithm of CT slices.

  2. Image processing methods to obtain symmetrical distribution from projection image.

    Science.gov (United States)

    Asano, H; Takenaka, N; Fujii, T; Nakamatsu, E; Tagami, Y; Takeshima, K

    2004-10-01

    Flow visualization and measurement of cross-sectional liquid distribution is very effective to clarify the effects of obstacles in a conduit on heat transfer and flow characteristics of gas-liquid two-phase flow. In this study, two methods to obtain cross-sectional distribution of void fraction are applied to vertical upward air-water two-phase flow. These methods need projection image only from one direction. Radial distributions of void fraction in a circular tube and a circular-tube annuli with a spacer were calculated by Abel transform based on the assumption of axial symmetry. On the other hand, cross-sectional distributions of void fraction in a circular tube with a wire coil whose conduit configuration rotates about the tube central axis periodically were measured by CT method based on the assumption that the relative distributions of liquid phase against the wire were kept along the flow direction.

  3. Automatic segmentation of bladder in CT images

    Institute of Scientific and Technical Information of China (English)

    Feng SHI; Jie YANG; Yue-min ZHU

    2009-01-01

    Segmentation of the bladder in computerized tomography (CT) images is an important step in radiation therapy planning of prostate cancer. We present a new segmentation scheme to automatically delineate the bladder contour in CT images with three major steps. First, we use the mean shift algorithm to obtain a clustered image containing the rough contour of the bladder, which is then extracted in the second step by applying a region-growing algorithm with the initial seed point selected from a line-by-line scanning process. The third step is to refine the bladder contour more accurately using the rolling-ball algorithm. These steps are then extended to segment the bladder volume in a slice-by-slice manner. The obtained results were compared to manual segmentation by radiation oncologists. The average values of sensitivity, specificity, positive predictive value, negative predictive value, and Hausdorff distance are 86.5%, 96.3%, 90.5%, 96.5%, and 2.8 pixels, respectively. The results show that the bladder can be accurately segmented.

  4. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  5. Ultrasonography Fused with PET-CT Hybrid Imaging

    DEFF Research Database (Denmark)

    Udesen, Jesper; Ewertsen, Caroline; Gran, Fredrik

    2011-01-01

    We present a method with fusion of images of three modalities 18F-FDG PET, CT, and 3-D ultrasound (US) applied to imaging of the anal canal and the rectum. To obtain comparable geometries in the three imaging modalities, a plexiglas rod, with the same dimensions as the US transducer, is placed...... in the anal canal prior to the PET-CT examination. The method is based on manual co-registration of PET-CT images and 3-D US images. The three-modality imaging of the rectum-anal canal may become useful as a supplement to conventional imaging in the external radiation therapy in the treatment of anal cancer......, where the precise delineation of a tumor is crucial to avoid damage from radiation therapy to the healthy tissue surrounding it. The technique is still in a phase of development, and the demands for integration different company software systems are significant before commercial application. Three...

  6. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  7. Quantitative Techniques in PET-CT Imaging

    NARCIS (Netherlands)

    Basu, Sandip; Zaidi, Habib; Holm, Soren; Alavi, Abass

    2011-01-01

    The appearance of hybrid PET/CT scanners has made quantitative whole body scanning of radioactive tracers feasible. This paper deals with the novel concepts for assessing global organ function and disease activity based on combined functional (PET) and structural (CT or MR) imaging techniques, their

  8. Automatic nonrigid registration of whole body CT mice images.

    Science.gov (United States)

    Li, Xia; Yankeelov, Thomas E; Peterson, Todd E; Gore, John C; Dawant, Benoit M

    2008-04-01

    Three-dimensional intra- and intersubject registration of image volumes is important for tasks that include quantification of temporal/longitudinal changes, atlas-based segmentation, computing population averages, or voxel and tensor-based morphometry. While a number of methods have been proposed to address this problem, few have focused on the problem of registering whole body image volumes acquired either from humans or small animals. These image volumes typically contain a large number of articulated structures, which makes registration more difficult than the registration of head images, to which the majority of registration algorithms have been applied. This article presents a new method for the automatic registration of whole body computed tomography (CT) volumes, which consists of two main steps. Skeletons are first brought into approximate correspondence with a robust point-based method. Transformations so obtained are refined with an intensity-based nonrigid registration algorithm that includes spatial adaptation of the transformation's stiffness. The approach has been applied to whole body CT images of mice, to CT images of the human upper torso, and to human head and neck CT images. To validate the authors method on soft tissue structures, which are difficult to see in CT images, the authors use coregistered magnetic resonance images. They demonstrate that the approach they propose can successfully register image volumes even when these volumes are very different in size and shape or if they have been acquired with the subjects in different positions.

  9. Virtual CT laparoscopic imaging using intravenous cholangiography with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Masafumi; Ishibashi, Masatoshi; Nishimura, Hiroshi; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine

    2000-08-01

    Laparoscopic cholecystectomy is a reatively new technology that allows for minimally invasive treatment of cholelithiasis. The purpose of this paper is to demonstrate the feasibility of virtual laparoscopic imaging using helical CT cholangiography with volume rendering technique. We used the technique with ten patients with suspected gallbladder abnormalities. Our imaging sets produced high quality 3D images with excellent visualization in 70% (7/10) of all cases. Virtual laparoscopic imaging was also compared with other imaging techniques and imaging using helical scans can proved useful in preoperative imaging. Furthermore, virtual laparoscopic imaging using helical scans can in surgical planning and serve as a visual aid in discussions between radiologists, surgeons, and patients. (author)

  10. Clinical feasibility of {sup 90}Y digital PET/CT for imaging microsphere biodistribution following radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Chadwick L.; Binzel, Katherine; Zhang, Jun; Knopp, Michael V. [The Ohio State University Wexner Medical Center, Wright Center of Innovation in Biomedical Imaging, Department of Radiology, Columbus, OH (United States); Wuthrick, Evan J. [The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Columbus, OH (United States)

    2017-07-15

    The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following {sup 90}Y microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC {sup 90}Y bremsstrahlung imaging immediately following routine radioembolization with 3.5 ± 1.7 GBq of {sup 90}Y-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 ± 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and {sup 90}Y biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of {sup 90}Y activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and {sup 90}Y-to-background image contrast while depicting {sup 90}Y biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined {sup 90}Y activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of {sup 90}Y microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of {sup 90}Y microsphere biodistribution. (orig.)

  11. Blind Analysis of CT Image Noise Using Residual Denoised Images

    CERN Document Server

    Roychowdhury, Sohini; Alessio, Adam

    2016-01-01

    CT protocol design and quality control would benefit from automated tools to estimate the quality of generated CT images. These tools could be used to identify erroneous CT acquisitions or refine protocols to achieve certain signal to noise characteristics. This paper investigates blind estimation methods to determine global signal strength and noise levels in chest CT images. Methods: We propose novel performance metrics corresponding to the accuracy of noise and signal estimation. We implement and evaluate the noise estimation performance of six spatial- and frequency- based methods, derived from conventional image filtering algorithms. Algorithms were tested on patient data sets from whole-body repeat CT acquisitions performed with a higher and lower dose technique over the same scan region. Results: The proposed performance metrics can evaluate the relative tradeoff of filter parameters and noise estimation performance. The proposed automated methods tend to underestimate CT image noise at low-flux levels...

  12. CT versus MR in neonatal brain imaging at term

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Richard L.; Robson, Caroline D.; Zurakowski, David; Antiles, Sharon; Strauss, Keith; Mulkern, Robert V. [Department of Radiology, Children' s Hospital Medical Center, Harvard Medical School, 300 Longwood Avenue, MA 02115, Boston (United States)

    2003-07-01

    Recent reports have highlighted the lifetime risk of malignancy from using ionizing radiation in pediatric imaging. Computed tomography (CT), which uses ionizing radiation, is employed extensively for neonatal brain imaging of term infants. Magnetic resonance (MR) provides an alternative that does not use ionizing radiation. The purpose of this study was to assess the cross-modality agreement and interobserver agreement of CT and MR brain imaging of the term or near-term neonate. Brain CT and MR images of 48 neonates were retrospectively reviewed by two pediatric neuroradiologists. CT and MR examinations had been obtained within 72 h of one another in all patients. CT was obtained with 5 mm collimation (KV=120, mAs=340). MR consisted of T1-weighted imaging (TR/TE=300/14; 4-mm slice thickness/1-mm gap), T2-weighted imaging (TR/TE/etl= 3000/126/16; 4-mm slice thickness/1-mm gap), and line scan diffusion imaging (LSDI) (TR/TE/b factor=1258/63/750; nominal 4-mm slice thickness/3-mm gap). The brain was categorized as normal or abnormal on both CT and MR. Ischemic injury was the most common brain abnormality demonstrated. McNemar's test indicated no significant difference between CT and MR test results for reader 1 (P=0.22) or reader 2 (P=0.45). The readers agreed on the presence or absence of abnormality on CT in 40 patients (83.3%) and on MR in 45 patients (93.8%). For CT, the kappa coefficient indicated excellent interobserver agreement ({kappa}=0.68), although the lower limit of the 95% confidence interval extends to {kappa}=0.55, which indicates only good-to-moderate agreement. For MR, the kappa coefficient indicated almost perfect interobserver agreement ({kappa}=0.88) with the 95% confidence interval extending to a lower limit of {kappa}=0.76, which represents excellent agreement. Because MR demonstrates findings similar to CT and has greater interobserver agreement, it appears that MR is a superior test to CT in determining brain abnormalities in the term

  13. SPECT/CT and tumour imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abikhzer, Gad [Rambam Health Care Campus, Department of Nuclear Medicine, Haifa (Israel); Keidar, Zohar [Rambam Health Care Campus, Department of Nuclear Medicine, Haifa (Israel); Technion - Israel Institute of Technology, The Ruth and Bruce Rappaport Faculty of Medicine, Haifa (Israel)

    2014-05-15

    Scintigraphic techniques are sensitive imaging modalities in the diagnosis and follow-up of cancer patients providing the functional and metabolic activity characteristics of the tumour. Hybrid SPECT/CT improves the diagnostic accuracy of these well-established imaging techniques by precise anatomical localization and characterization of morphological findings, differentiation between foci of physiological and pathological tracer uptake, resulting in a significant impact on patient management and more definitive interpretations. The use of SPECT/CT has been studied in a variety of applications in tumour imaging which are reviewed in this article. By combining functional and anatomical information in a single imaging session, SPECT/CT has become a one-stop cancer imaging modality. (orig.)

  14. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  15. Size and CT density of iodine-containing ethosomal vesicles obtained by membrane extrusion: potential for use as CT contrast agents.

    Science.gov (United States)

    Na, Bomin; Choi, Byoung Wook; Kim, Bumsang

    2013-11-01

    Computed tomography (CT) is the primary non-invasive imaging technique used for most patients with suspected liver disease. In order to improve liver-specific imaging properties and prevent toxic effects in patients with compromised renal function, we investigated the encapsulation of iodine within ethosomal vesicles. As a first step in the development of novel contrast agents using ethosomes for CT imaging applications, iodine was entrapped within ethosomes and iodine-containing ethosomes of the desired size were obtained by extrusion using a polycarbonate membrane with a defined pore size. Ethosomes containing iodine showed a relatively high CT density, which decreased when they were extruded, due to the rupture and re-formation of the lipid bilayer of the ethosome. However, when a solution with a high iodine concentration was used as a dispersion media during the extrusion process, the decrease in CT density could be prevented. In addition, ethosomes containing iodine were taken up efficiently by macrophages, which are abundant in the liver, and these ethosomes exhibited no cellular toxicity. These results demonstrate that iodine could be entrapped within ethosomal vesicles, giving the ethosomes a relatively high CT density, and that the extrusion technique used in this study could conveniently and reproducibly produce ethosomal vesicles with a desired size. Therefore, ethosomes containing iodine, as prepared in this study, have potential as contrast agents with applications in CT imaging.

  16. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2012-01-01

    This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...... into a standard image registration framework with a composition of a global affine and several free-form B-Spline transformations with increasing grid resolution. The proposed mass preserving registration method is compared to registration using the sum of squared intensity differences as a similarity function...... inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant...

  17. Image Analysis in CT Angiography

    NARCIS (Netherlands)

    Manniesing, R.

    2006-01-01

    In this thesis we develop and validate novel image processing techniques for the analysis of vascular structures in medical images. First a new type of filter is proposed which is capable of enhancing vascular structures while suppressing noise in the remainder of the image. This filter is based on

  18. The maxillomandibular ameloblastoma: CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Han, Moon Hee; Kim, Myung Jin; Chang, Kee Hyun [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-02-15

    We retrospectively performed this study to evaluate the characteristic findings of maxillomandibular ameloblastomas on CT and MR imaging. We reviewed histologically proved 12 cases of ameloblastomas, of which 7 cases were postoperative recurrent tumors, one of twelve cases was presumed ameloblastic carcinoma. Eleven cases were examined with CT and 3 cases with MR. The types were solid in 4, unicystic in 4, and mixed in the rest 4. CT and MRI of 11 ameloblastomas showed concentric expansile mass (n = 11), cortical bone thinning and focal bone destruction by the tumors (n = 9), well-margined, expansile destruction of surrounding sturctures (n = 9), focal bulging of the tumors (n = 6) and focal poorly-marginated invasion of tissue planes (n = 4). Ameloblastic carcinoma showed ill-defined irregular margin, aggressive invasion of surrounding structures and hematogeneous lung metastasis. Unerupted teeth or mural modules were found in unicystic ameloblastomas. All three tumors examined by MRI showed isointensity to muscle on T1 weighted images and slight hyperintensity on T2 weighted images. The wall, septa and solid portions of the tumors were strongly enhanced on MR imaging. There was no difference in CT ro MR finding between primary and recurrent tumors. Ameloblastomas showed solid, cystic or mixed pattern, and commonly well marginated expansile contour with local aggressiveness. Presence of mural nodules on CT in unicystic ameloblastoma with unerupted tooth was helpful in distinguishing ameloblastoma from dentigerous cyst.

  19. CT imaging with a mobile C-arm prototype

    Science.gov (United States)

    Cheryauka, Arvi; Tubbs, David; Langille, Vinton; Kalya, Prabhanjana; Smith, Brady; Cherone, Rocco

    2008-03-01

    Mobile X-ray imagery is an omnipresent tool in conventional musculoskeletal and soft tissue applications. The next generation of mobile C-arm systems can provide clinicians of minimally-invasive surgery and pain management procedures with both real-time high-resolution fluoroscopy and intra-operative CT imaging modalities. In this study, we research two C-arm CT experimental system configurations and evaluate their imaging capabilities. In a non-destructive evaluation configuration, the X-ray Tube - Detector assembly is stationary while an imaging object is placed on a rotating table. In a medical imaging configuration, the C-arm gantry moves around the patient and the table. In our research setting, we connect the participating devices through a Mobile X-Ray Imaging Environment known as MOXIE. MOXIE is a set of software applications for internal research at GE Healthcare - Surgery and used to examine imaging performance of experimental systems. Anthropomorphic phantom volume renderings and orthogonal slices of reconstructed images are obtained and displayed. The experimental C-arm CT results show CT-like image quality that may be suitable for interventional procedures, real-time data management, and, therefore, have great potential for effective use on the clinical floor.

  20. MR and CT image fusion of the cervical spine: a noninvasive alternative to CT-myelography

    Science.gov (United States)

    Hu, Yangqiu; Mirza, Sohail K.; Jarvik, Jeffrey G.; Heagerty, Patrick J.; Haynor, David R.

    2005-04-01

    CT-Myelography (CTM) is routinely used for planning surgery for degenerative disease of the spine, but its invasive nature, significant potential morbidity, and high costs make a noninvasive substitute desirable. We report our work on evaluating CT and MR image fusion as an alternative to CTM. Because the spine is only piecewise rigid, a multi-rigid approach to the registration of spinal CT and MR images was developed (SPIE 2004), in which the spine on CT images is first segmented into separate vertebrae, each of which is then rigidly registered with the corresponding vertebra on MR images. The results are then blended to obtain fusion images. Since they contain information from both modalities, we hypothesized that fusion images would be equivalent to CTM. To test this we selected 34 patients who had undergone MRI and CTM for degenerative disease of the cervical spine, and used the multi-rigid approach to produce fused images. A clinical vignette for each patient was created and presented along with either CT/MR fusion images or CTM images. A group of spine surgeons are asked to formulate detailed surgical plans based on each set of images, and the surgical plans are compared. A similar study assessing diagnostic agreement is being performed with neuroradiologists, who also assess the accuracy of registration. Our work to date has demonstrated the feasibility of segmentation and multi-rigid fusion in clinical cases and the acceptability of the questionnaire to physicians. Preliminary analysis of one surgeon's and one neuroradiologist"s evaluation has been performed.

  1. Modern CT and PET/CT imaging of the liver; Moderne CT- und PET/CT-Bildgebung der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J.; Heusner, T.A.; Riegger, C.; Reichelt, D.; Kuhlemann, J.; Antoch, G.; Blondin, D. [Medizinische Fakultaet, Heinrich-Heine-Universitaet Duesseldorf, Institut fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2011-08-15

    Computed tomography (CT) is now widely available and represents an important and rapid method for the diagnostics of acute liver disease, characterization of focal liver lesions, planning of interventional therapy measures and postintervention control. In recent years CT has not become less important despite the increasing value of magnetic resonance imaging (MRI). By the use of different contrast medium phases good characterization of space-occupying lesions can be achieved. For the diagnostics of hepatocellular carcinoma (HCC) a triphasic examination protocol should always be implemented. The introduction of dual energy CT increased the sensitivity of imaging of hypervascularized and hypovascularized liver lesions and by the use of virtual native imaging it has become possible to avoid additional native imaging which reduces the x-ray exposition of patients. Positron emission tomography (PET) has an advantage for imaging in oncology because nearly the complete body of the patient can be screened and this is the main indication for PET/CT (whole-body staging). For purely hepatic problems 18F-fluorodeoxyglucose (FDG)-PET/CT using diagnostic CT data has a higher precision than CT alone but is inferior to MRI. (orig.) [German] Die Computertomographie (CT) ist heute breit verfuegbar und stellt eine wichtige und schnelle Methode zur Diagnostik akuter Lebererkrankungen, der Artdiagnostik fokaler Leberlaesionen und der Planung interventioneller Therapiemassnahmen sowie der postinterventionellen Kontrolle dar. In den letzten Jahren hat die CT trotz des zunehmenden Stellenwerts der Magnetresonanztomographie (MRT) nicht an Bedeutung verloren. Durch den Einsatz unterschiedlicher Kontrastmittelphasen kann meist eine gute Charakterisierung von Raumforderungen erfolgen. Bei der Diagnostik des hepatozellulaeren Karzinoms (HCC) sollte beispielsweise immer ein triphasisches Untersuchungsprotokoll angewendet werden. Mit Einfuehrung der Dual-energy-CT hat die Sensitivitaet in der

  2. Pediatric renal leukemia: spectrum of CT imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Hilmes, Melissa A. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); Vanderbilt University Children' s Hospital, Section of Pediatric Radiology, Nashville, TN (United States); Dillman, Jonathan R. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Mody, Rajen J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Division of Pediatric Hematology-Oncology and Bone Marrow Transplantation, Ann Arbor, MI (United States); Strouse, Peter J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States)

    2008-04-15

    The kidneys are a site of extramedullary leukemic disease that can be readily detected by CT. To demonstrate the spectrum of CT findings in children with renal leukemic involvement. Twelve children were identified retrospectively as having renal leukemic involvement by contrast-enhanced CT of the abdomen. Contrast-enhanced CT images through the kidneys of each patient were reviewed by two pediatric radiologists. Pertinent imaging findings and renal lengths were documented. The electronic medical record was accessed to obtain relevant clinical and pathologic information. Five patients with renal leukemic involvement presented with multiple bilateral low-attenuation masses, while three patients demonstrated large areas of wedge-shaped and geographic low attenuation. Four other patients presented with unique imaging findings, including a solitary unilateral low-attenuation mass, solitary bilateral low-attenuation masses, multiple bilateral low-attenuation masses including unilateral large conglomerate masses, and bilateral areas of ill-defined parenchymal low attenuation. Two patients showed unilateral nephromegaly, while eight other patients showed bilateral nephromegaly. Two patients had normal size kidneys. Two patients had elevated serum creatinine concentrations at the time of imaging. Renal leukemic involvement in children can present with a variety of CT imaging findings. Focal renal abnormalities as well as nephromegaly are frequently observed. Most commonly, renal leukemic involvement does not appear to impair renal function. (orig.)

  3. Liver recognition based on statistical shape model in CT images

    Science.gov (United States)

    Xiang, Dehui; Jiang, Xueqing; Shi, Fei; Zhu, Weifang; Chen, Xinjian

    2016-03-01

    In this paper, an automatic method is proposed to recognize the liver on clinical 3D CT images. The proposed method effectively use statistical shape model of the liver. Our approach consist of three main parts: (1) model training, in which shape variability is detected using principal component analysis from the manual annotation; (2) model localization, in which a fast Euclidean distance transformation based method is able to localize the liver in CT images; (3) liver recognition, the initial mesh is locally and iteratively adapted to the liver boundary, which is constrained with the trained shape model. We validate our algorithm on a dataset which consists of 20 3D CT images obtained from different patients. The average ARVD was 8.99%, the average ASSD was 2.69mm, the average RMSD was 4.92mm, the average MSD was 28.841mm, and the average MSD was 13.31%.

  4. Image quality evaluation of virtual monoenergetic spectral images obtained in two types of dual energy CT based on noise level%两种双能CT技术虚拟单能谱图像的噪声比较研究

    Institute of Scientific and Technical Information of China (English)

    周旸; 曾勇明; 周密; 高志梅; 孙静坤

    2016-01-01

    Objective To investigate the image quality difference of the virtual monochromatic spectral(VMS) images synthesized from fast kilovoltage switching and dual-source dual-energy CT for a given radiation dose. Methods A plurality of disposable syringes containing 15 mg/ml iodine contrast agent and saline were placed on the surface of the male anthropomorphic phantom consisting ofhead neck and torso, GE HD750 gemstone spectral imaging and Siemens Somatom Definition Flash dual energy CT protocols were performed on the phantom for a same dose(volume CT dose index 6.52 mGy), and VMS images (40, 60, 70, 80, 100, 120, 140 keV) were reconstructed and obtained(VMSkV switching and VMSdual-source image), respectively. The objective image noise, iodine signal noise ratio(SNR), iodine contrast noise ratio (CNR) and CT values were measured. The results were analyzed using the paired t test and ANOVA. Results All VMS iodine CT values were gradually decreased with the increasing of keV , and iodine CT values on VMSdual-source images were greater than on VMSkV switching images(P<0.05), VMSkV switching iodine CT values in descending order from the head , chest, abdomen at less than 100 keV,while most VMSdual-source iodine CT values were highest on chest(P<0.05). VMSdual-source and VMSkV switching image noise were highest at 40 keV and successively raised from the head, chest , abdomen. VMSkV switching image noise gradually decreased with the increase of keV in the range of 40 to 70 keV , gradually increased up to the trough after 70 keV from 80 keV gradually decreased, while VMSdual-source image noise was lowest at 70 keV or 80 keV , and then with the keV increased gradually increased. Image noise on VMSkV switching images in the range of 40 to 100 keV were higher than that on VMSdual-source images and lower in the range of 100 to 140 keV at most part(P<0.05). VMSdual-source and VMSkV switching iodine SNR were highest at 40 keV or 60 keV,SNR on VMSdual-source images are greater than

  5. Intracranial Hemorrhage Annotation for CT Brain Images

    Directory of Open Access Journals (Sweden)

    Tong Hau Lee

    2011-01-01

    Full Text Available In this paper, we created a decision-making model to detect intracranial hemorrhage and adopted Expectation Maximization(EM segmentation to segment the Computed Tomography (CT images. In this work, basically intracranial hemorrhage is classified into two main types which are intra-axial hemorrhage and extra-axial hemorrhage. In order to ease classification, contrast enhancement is adopted to finetune the contrast of the hemorrhage. After that, k-means is applied to group the potential and suspicious hemorrhagic regions into one cluster. The decision-making process is to identify whether the suspicious regions are hemorrhagic regions or non-regions of interest. After the hemorrhagic detection, the images are segmented into brain matter and cerebrospinal fluid (CSF by using expectation-maximization (EM segmentation. The acquired experimental results are evaluated in terms of recall and precision. The encouraging results have been attained whereby the proposed system has yielded 0.9333 and 0.8880 precision for extra-axial and intra-axial hemorrhagic detection respectively, whereas recall rate obtained is 0.9245 and 0.8043 for extra-axial and intra-axial hemorrhagic detection respectively.

  6. Imaging of jaw with dental CT software program: Normal Anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myong Gon; Seo, Kwang Hee; Jung, Hak Young; Sung, Nak Kwan; Chung, Duk Soo; Kim, Ok Dong [School of Medicine, Taegu Catholic University, Taegu (Korea, Republic of); Lee, Young Hwan [Taegu Armed Forces General Hospital, Taegu (Korea, Republic of)

    1994-07-15

    Dental CT software program can provide reformatted cross-sectional and panoramic images that cannot be obtained with conventional axial and direct coronal CT scan. The purpose of this study is to describe the method of the technique and to identify the precise anatomy of jaw. We evaluated 13 mandibles and 7 maxillae of 15 subjects without bony disease who were being considered for endosseous dental implants. Reformatted images obtained by the use of bone algorithm performed on GE HiSpeed Advantage CT scanner were retrospectively reviewed for detailed anatomy of jaw. Anatomy related to neurovascular bundle(mandibular foramen, inferior alveolar canal, mental foramen, canal for incisive artery, nutrient canal, lingual foramen and mylohyoid groove), muscular insertion(mylohyoid line, superior and inferior genial tubercle and digastric fossa) and other anatomy(submandibular fossa, sublingual fossa, contour of alveolar process, oblique line, retromolar fossa, temporal crest and retromolar triangle) were well delineated in mandible. In maxilla, anatomy related to neurovascular bundle(greater palatine foramen and groove, nasopalatine canal and incisive foramen) and other anatomy(alveolar process, maxillary sinus and nasal fossa) were also well delineated. Reformatted images using dental CT software program provided excellent delineation of the jaw anatomy. Therefore, dental CT software program can play an important role in the preoperative assessment of mandible and maxilla for dental implants and other surgical conditions.

  7. Techniques in Iterative Proton CT Image Reconstruction

    CERN Document Server

    Penfold, Scott

    2015-01-01

    This is a review paper on some of the physics, modeling, and iterative algorithms in proton computed tomography (pCT) image reconstruction. The primary challenge in pCT image reconstruction lies in the degraded spatial resolution resulting from multiple Coulomb scattering within the imaged object. Analytical models such as the most likely path (MLP) have been proposed to predict the scattered trajectory from measurements of individual proton location and direction before and after the object. Iterative algorithms provide a flexible tool with which to incorporate these models into image reconstruction. The modeling leads to a large and sparse linear system of equations that can efficiently be solved by projection methods-based iterative algorithms. Such algorithms perform projections of the iterates onto the hyperlanes that are represented by the linear equations of the system. They perform these projections in possibly various algorithmic structures, such as block-iterative projections (BIP), string-averaging...

  8. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  9. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  10. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a good'' surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  11. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a ``good`` surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  12. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  13. New frontiers in CT imaging of airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine [Department of Radiology, University Pierre et Marie Curie, Paris (France); Fetita, Catalin; Preteux, Francoise [Institut National des Telecommunications, Department ARTEMIS, Evry (France); Brauner, Michel W. [Avicenne Hospital, UFR SMBH Paris XIII, Bobigny (France); Lenoir, Stephane [Institut Mutualiste Montsouris, Paris (France)

    2002-05-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  14. Multi-institutional MicroCT image comparison of image-guided small animal irradiators

    Science.gov (United States)

    Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena

    2017-07-01

    To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2  >  0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR  >  36 and noise levels  1.5 lp mm-1 for MTF  =  0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set

  15. Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study

    Science.gov (United States)

    Lee, Youngjin; Lee, Seungwan; Kim, Hee-Joung

    2016-04-01

    Photon-counting detectors allow spectral computed tomography (CT) imaging using energy-resolved information from a polychromatic X-ray spectrum. The spectral CT images based on the photon-counting detectors are dependent on the energy ranges defined by energy bins for image acquisition. In this study, K-edge and energy weighting imaging methods were experimentally implemented by using a spectral CT system with a cadmium zinc telluride (CZT)-based photon-counting detector. The spectral CT images were obtained by various energy bins and compared in terms of CNR improvement for investigating the effect of energy bins and the efficiency of the spectral CT imaging methods. The results showed that the spectral CT image quality was improved by using the particular energy bins, which were optimized for each spectral CT imaging method and target material. The CNR improvement was different for the spectral CT imaging methods and target materials. It can be concluded that an appropriate selection of imaging method for each target material and the optimization of energy bin can maximize the quality of spectral CT images.

  16. Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youngjin [Department of Radiological Science, College of Health Science, Eulji University, 553 Sangseong-daero, Seongnam, Gyeonggi-do 461-713 (Korea, Republic of); Lee, Seungwan, E-mail: slee1@konyang.ac.kr [Department of Radiological Science, College of Medical Science, Konyang University, 158 Gwanjeodong-ro, Daejeon 302-812 (Korea, Republic of); Kim, Hee-Joung [Department of Radiological Science, College of Health Science, Yonsei University, 1 Yonseidae-gil, Wonju, Kangwon-do 220-710 (Korea, Republic of)

    2016-04-11

    Photon-counting detectors allow spectral computed tomography (CT) imaging using energy-resolved information from a polychromatic X-ray spectrum. The spectral CT images based on the photon-counting detectors are dependent on the energy ranges defined by energy bins for image acquisition. In this study, K-edge and energy weighting imaging methods were experimentally implemented by using a spectral CT system with a cadmium zinc telluride (CZT)-based photon-counting detector. The spectral CT images were obtained by various energy bins and compared in terms of CNR improvement for investigating the effect of energy bins and the efficiency of the spectral CT imaging methods. The results showed that the spectral CT image quality was improved by using the particular energy bins, which were optimized for each spectral CT imaging method and target material. The CNR improvement was different for the spectral CT imaging methods and target materials. It can be concluded that an appropriate selection of imaging method for each target material and the optimization of energy bin can maximize the quality of spectral CT images.

  17. Clinical micro-CT for dental imaging

    Science.gov (United States)

    Youn, Hanbean; Cho, Min Kook; Shon, Cheol-Soon; Cho, Bong Hae; Kim, Chang Hyuk; Kim, Ho Kyung

    2009-02-01

    We exploit the development of a clinical computed microtomography (micro-CT) system for dental imaging. While the conventional dental CT simply serves implant treatment, the clinical dental micro-CT may provide clinicians with a histologic evaluation. To investigate the feasibility of the realization of a dental micro-CT, we have constructed an experimental test system which mainly consists of a microfocus x-ray source, a rotational subject holder, and a flat-panel detector. The flat-panel detector is based on a matrix-addressed photodiode array coupled to a CsI:Tl scintillator. The detective quantum efficiency (DQE) of the detector was measured as a function of magnification based on the measured modulation-transfer function (MTF) and noise-power spectrum (NPS). The best MTF and DQE performances were achieved at the magnification factor of 3. Similar tendency of the spatial resolving power in tomography was also observed with a wire phantom having a 25 μm diameter. From the investigation of tomographs reconstructed from a humanoid skull phantom, the application of magnification in the system largely reduced both signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for a fixed dose at the entrance surface of the detector, 1.2 mGy, while this setup increased the dose at the object plane from 4.7 mGy to 19.1 mGy for the magnification factor from 2 to 4, respectively. Although the quantum mottles at the high magnification factor tackled the practical use in the clinic, the information contained in the magnified CT images was quite promising.

  18. RONI Based Secured and Authenticated Indexing of Lung CT Images.

    Science.gov (United States)

    Jasmine Selvakumari Jeya, I; Suganthi, J

    2015-01-01

    Medical images need to be transmitted with the patient's information without altering the image data. The present paper discusses secured indexing of lung CT image (SILI) which is a secured way of indexing the lung CT images with the patient information. Authentication is provided using the sender's logo information and the secret key is used for embedding the watermark into the host image. Watermark is embedded into the region of Noninterest (RONI) of the lung CT image. RONI is identified by segmenting the lung tissue from the CT scan image. The experimental results show that the proposed approach is robust against unauthorized access, noise, blurring, and intensity based attacks.

  19. Body-wide anatomy recognition in PET/CT images

    Science.gov (United States)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Zhao, Liming; Torigian, Drew A.

    2015-03-01

    With the rapid growth of positron emission tomography/computed tomography (PET/CT)-based medical applications, body-wide anatomy recognition on whole-body PET/CT images becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem and seldom studied due to unclear anatomy reference frame and low spatial resolution of PET images as well as low contrast and spatial resolution of the associated low-dose CT images. We previously developed an automatic anatomy recognition (AAR) system [15] whose applicability was demonstrated on diagnostic computed tomography (CT) and magnetic resonance (MR) images in different body regions on 35 objects. The aim of the present work is to investigate strategies for adapting the previous AAR system to low-dose CT and PET images toward automated body-wide disease quantification. Our adaptation of the previous AAR methodology to PET/CT images in this paper focuses on 16 objects in three body regions - thorax, abdomen, and pelvis - and consists of the following steps: collecting whole-body PET/CT images from existing patient image databases, delineating all objects in these images, modifying the previous hierarchical models built from diagnostic CT images to account for differences in appearance in low-dose CT and PET images, automatically locating objects in these images following object hierarchy, and evaluating performance. Our preliminary evaluations indicate that the performance of the AAR approach on low-dose CT images achieves object localization accuracy within about 2 voxels, which is comparable to the accuracies achieved on diagnostic contrast-enhanced CT images. Object recognition on low-dose CT images from PET/CT examinations without requiring diagnostic contrast-enhanced CT seems feasible.

  20. Phase and amplitude binning for 4D-CT imaging

    Science.gov (United States)

    Abdelnour, A. F.; Nehmeh, S. A.; Pan, T.; Humm, J. L.; Vernon, P.; Schöder, H.; Rosenzweig, K. E.; Mageras, G. S.; Yorke, E.; Larson, S. M.; Erdi, Y. E.

    2007-07-01

    We compare the consistency and accuracy of two image binning approaches used in 4D-CT imaging. One approach, phase binning (PB), assigns each breathing cycle 2π rad, within which the images are grouped. In amplitude binning (AB), the images are assigned bins according to the breathing signal's full amplitude. To quantitate both approaches we used a NEMA NU2-2001 IEC phantom oscillating in the axial direction and at random frequencies and amplitudes, approximately simulating a patient's breathing. 4D-CT images were obtained using a four-slice GE Lightspeed CT scanner operating in cine mode. We define consistency error as a measure of ability to correctly bin over repeated cycles in the same field of view. Average consistency error μe ± σe in PB ranged from 18% ± 20% to 30% ± 35%, while in AB the error ranged from 11% ± 14% to 20% ± 24%. In PB nearly all bins contained sphere slices. AB was more accurate, revealing empty bins where no sphere slices existed. As a proof of principle, we present examples of two non-small cell lung carcinoma patients' 4D-CT lung images binned by both approaches. While AB can lead to gaps in the coronal images, depending on the patient's breathing pattern, PB exhibits no gaps but suffers visible artifacts due to misbinning, yielding images that cover a relatively large amplitude range. AB was more consistent, though often resulted in gaps when no data existed due to patients' breathing pattern. We conclude AB is more accurate than PB. This has important consequences to treatment planning and diagnosis.

  1. Phase and amplitude binning for 4D-CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abdelnour, A F [US Patent and Trademark Office, Alexandria, VA (United States); Nehmeh, S A [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Pan, T [M.D. Anderson Cancer Center, Houston, TX (United States); Humm, J L [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Vernon, P [GE Healthcare Technologies, Waukesha, WI (United States); Schoeder, H [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Rosenzweig, K E [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Mageras, G S [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Yorke, E [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Larson, S M [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Erdi, Y E [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2007-07-21

    We compare the consistency and accuracy of two image binning approaches used in 4D-CT imaging. One approach, phase binning (PB), assigns each breathing cycle 2{pi} rad, within which the images are grouped. In amplitude binning (AB), the images are assigned bins according to the breathing signal's full amplitude. To quantitate both approaches we used a NEMA NU2-2001 IEC phantom oscillating in the axial direction and at random frequencies and amplitudes, approximately simulating a patient's breathing. 4D-CT images were obtained using a four-slice GE Lightspeed CT scanner operating in cine mode. We define consistency error as a measure of ability to correctly bin over repeated cycles in the same field of view. Average consistency error {mu}{sub e} {+-} {sigma}{sub e} in PB ranged from 18% {+-} 20% to 30% {+-} 35%, while in AB the error ranged from 11% {+-} 14% to 20% {+-} 24%. In PB nearly all bins contained sphere slices. AB was more accurate, revealing empty bins where no sphere slices existed. As a proof of principle, we present examples of two non-small cell lung carcinoma patients' 4D-CT lung images binned by both approaches. While AB can lead to gaps in the coronal images, depending on the patient's breathing pattern, PB exhibits no gaps but suffers visible artifacts due to misbinning, yielding images that cover a relatively large amplitude range. AB was more consistent, though often resulted in gaps when no data existed due to patients' breathing pattern. We conclude AB is more accurate than PB. This has important consequences to treatment planning and diagnosis.

  2. CT perfusion image processing: analysis of liver tumors

    OpenAIRE

    D’Antò, Michela

    2013-01-01

    Perfusion CT imaging of the liver has potential to improve evaluation of tumour angiogenesis. Quantitative parameters can be obtained applying mathematical models to Time Attenuation Curve (TAC). However, there are still some difficulties for an accurate quantification of perfusion parameters due, for example, to algorithms employed, to mathematical model, to patient’s weight and cardiac output and to the acquisition system. In this thesis, new parameters and alternative methodologies ab...

  3. Incidental Detection of Interstitial Pregnancy on CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of)

    2010-02-15

    Ectopic pregnancy is a potentially life-threatening condition. Detection of ectopic pregnancy on CT images is rare. In this case, we describe the CT findings of interstitial pregnancy both before and after rupture. If CT images demonstrate the presence of a strong enhancing ring-like mass in the pelvis, ectopic pregnancy should be considered

  4. Functional CT imaging of prostate cancer

    Science.gov (United States)

    Henderson, Elizabeth; Milosevic, Michael F.; Haider, Masoom A.; Yeung, Ivan W. T.

    2003-09-01

    The purpose of this paper is to investigate the distribution of blood flow (F), mean capillary transit time (Tc), capillary permeability (PS) and blood volume (vb) in prostate cancer using contrast-enhanced CT. Nine stage T2-T3 prostate cancer patients were enrolled in the study. Following bolus injection of a contrast agent, a time series of CT images of the prostate was acquired. Functional maps showing the distribution of F, Tc, PS and vb within the prostate were generated using a distributed parameter tracer kinetic model, the adiabatic approximation to the tissue homogeneity model. The precision of the maps was assessed using covariance matrix analysis. Finally, maps were compared to the findings of standard clinical investigations. Eight of the functional maps demonstrated regions of increased F, PS and vb, the locations of which were consistent with the results of standard clinical investigations. However, model parameters other than F could only be measured precisely within regions of high F. In conclusion functional CT images of cancer-containing prostate glands demonstrate regions of elevated F, PS and vb. However, caution should be used when applying a complex tracer kinetic model to the study of prostate cancer since not all parameters can be measured precisely in all areas.

  5. 3D Interpolation Method for CT Images of the Lung

    Directory of Open Access Journals (Sweden)

    Noriaki Asada

    2003-06-01

    Full Text Available A 3-D image can be reconstructed from numerous CT images of the lung. The procedure reconstructs a solid from multiple cross section images, which are collected during pulsation of the heart. Thus the motion of the heart is a special factor that must be taken into consideration during reconstruction. The lung exhibits a repeating transformation synchronized to the beating of the heart as an elastic body. There are discontinuities among neighboring CT images due to the beating of the heart, if no special techniques are used in taking CT images. The 3-D heart image is reconstructed from numerous CT images in which both the heart and the lung are taken. Although the outline shape of the reconstructed 3-D heart is quite unnatural, the envelope of the 3-D unnatural heart is fit to the shape of the standard heart. The envelopes of the lung in the CT images are calculated after the section images of the best fitting standard heart are located at the same positions of the CT images. Thus the CT images are geometrically transformed to the optimal CT images fitting best to the standard heart. Since correct transformation of images is required, an Area oriented interpolation method proposed by us is used for interpolation of transformed images. An attempt to reconstruct a 3-D lung image by a series of such operations without discontinuity is shown. Additionally, the same geometrical transformation method to the original projection images is proposed as a more advanced method.

  6. Segmentation-based CT image compression

    Science.gov (United States)

    Thammineni, Arunoday; Mukhopadhyay, Sudipta; Kamath, Vidya

    2004-04-01

    The existing image compression standards like JPEG and JPEG 2000, compress the whole image as a single frame. This makes the system simple but inefficient. The problem is acute for applications where lossless compression is mandatory viz. medical image compression. If the spatial characteristics of the image are considered, it can give rise to a more efficient coding scheme. For example, CT reconstructed images have uniform background outside the field of view (FOV). Even the portion within the FOV can be divided as anatomically relevant and irrelevant parts. They have distinctly different statistics. Hence coding them separately will result in more efficient compression. Segmentation is done based on thresholding and shape information is stored using 8-connected differential chain code. Simple 1-D DPCM is used as the prediction scheme. The experiments show that the 1st order entropies of images fall by more than 11% when each segment is coded separately. For simplicity and speed of decoding Huffman code is chosen for entropy coding. Segment based coding will have an overhead of one table per segment but the overhead is minimal. Lossless compression of image based on segmentation resulted in reduction of bit rate by 7%-9% compared to lossless compression of whole image as a single frame by the same prediction coder. Segmentation based scheme also has the advantage of natural ROI based progressive decoding. If it is allowed to delete the diagnostically irrelevant portions, the bit budget can go down as much as 40%. This concept can be extended to other modalities.

  7. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  8. Automated determination of spinal centerline in CT and MR images

    Science.gov (United States)

    Štern, Darko; Vrtovec, Tomaž; Pernuš, Franjo; Likar, Boštjan

    2009-02-01

    The spinal curvature is one of the most important parameters for the evaluation of spinal deformities. The spinal centerline, represented by the curve that passes through the centers of the vertebral bodies in three-dimensions (3D), allows valid quantitative measurements of the spinal curvature at any location along the spine. We propose a novel automated method for the determination of the spinal centerline in 3D spine images. Our method exploits the anatomical property that the vertebral body walls are cylindrically-shaped and therefore the lines normal to the edges of the vertebral body walls most often intersect in the middle of the vertebral bodies, i.e. at the location of spinal centerline. These points of intersection are first obtained by a novel algorithm that performs a selective search in the directions normal to the edges of the structures and then connected with a parametric curve that represents the spinal centerline in 3D. As the method is based on anatomical properties of the 3D spine anatomy, it is modality-independent, i.e. applicable to images obtained by computed tomography (CT) and magnetic resonance (MR). The proposed method was evaluated on six CT and four MR images (T1- and T2-weighted) of normal spines and on one scoliotic CT spine image. The qualitative and quantitative results for the normal spines show that the spinal centerline can be successfully determined in both CT and MR spine images, while the results for the scoliotic spine indicate that the method may also be used to evaluate pathological curvatures.

  9. Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies

    Science.gov (United States)

    Murase, Kenya; Nanjo, Takafumi; Satoshi, Ii; Miyazaki, Shohei; Hirata, Masaaki; Sugawara, Yoshifumi; Kudo, Masayuki; Sasaki, Kousuke; Mochizuki, Teruhito

    2005-11-01

    The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation × 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current.

  10. Information extraction and CT reconstruction of liver images based on diffraction enhanced imaging

    Institute of Scientific and Technical Information of China (English)

    Chunhong Hu; Tao Zhao; Lu Zhang; Hui Li; Xinyan Zhao; Shuqian Luo

    2009-01-01

    X-ray phase-contrast imaging (PCI) is a new emerging imaging technique that generates a high spatial resolution and high contrast of biological soft tissues compared to conventional radiography. Herein a biomedical application of diffraction enhanced imaging (DEI) is presented. As one of the PCI methods, DEI derives contrast from many different kinds of sample information, such as the sample's X-ray absorption, refraction gradient and ultra-small-angle X-ray scattering (USAXS) properties, and the sample information is expressed by three parametric images. Combined with computed tomography (CT), DEI-CT can produce 3D volumetric images of the sample and can be used for investigating micro-structures of biomedical samples. Our DEI experiments for fiver samples were implemented at the topog-raphy station of Beijing Synchrotron Radiation Facility (BSRF). The results show that by using our provided information extraction method and DEI-CT reconstruction approach, the obtained parametric images clearly display the inner structures of liver tissues and the morphology of blood vessels. Furthermore, the reconstructed 3D view of the fiver blood vessels exhibits the micro blood vessels whose minimum diameter is on the order of about tens of microns, much better than its conventional CT reconstruction at a millimeter resolution.In conclusion, both the information extraction method and DEI-CT have the potential for use in biomedical micro-structures analysis.

  11. Myocardial perfusion imaging with dual energy CT.

    Science.gov (United States)

    Jin, Kwang Nam; De Cecco, Carlo N; Caruso, Damiano; Tesche, Christian; Spandorfer, Adam; Varga-Szemes, Akos; Schoepf, U Joseph

    2016-10-01

    Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  12. CT myocardial perfusion imaging: current status and future directions.

    Science.gov (United States)

    Williams, M C; Newby, D E

    2016-08-01

    Computed tomography (CT) imaging of the heart has advanced rapidly, and it is now possible to perform a comprehensive assessment at a low radiation dose. CT myocardial perfusion imaging can provide additive information to CT coronary angiography, and is particularly useful in patients with heavily calcified coronary arteries or coronary artery stents. A number of protocols are now available for CT myocardial perfusion including static, dynamic, and dual-energy techniques. This review will discuss the current status of CT myocardial perfusion imaging, its clinical application, and future directions for this technology.

  13. A CT-, PET- and MR-imaging-compatible hyperbaric pressure chamber for baromedical research

    DEFF Research Database (Denmark)

    Hansen, Kasper; Søvsø Szocska Hansen, Esben; Tolbod, Lars P;

    2015-01-01

    OBJECTIVES: We describe the development of a novel preclinical rodent-sized pressure chamber system compatible with computed tomography (CT), positron emission tomography (PET) and magnetic resonance imaging (MRI) that allows continuous uncompromised and minimally invasive data acquisition...... different tissues in the MRI phantoms. CONCLUSION: This study demonstrates a pressure chamber system compatible with CT, PET and MRI. We found that no correction in image intensity was required with pressurisation up to 1.013 mPa for any imaging modality. CT, PET or MRI can be used to obtain anatomical...... throughout hyperbaric exposures. The effect of various pressures on the acquired image intensity obtained with different CT, PET and MRI phantoms are characterised. MATERIAL AND METHODS: Tissue-representative phantom models were examined with CT, PET or MRI at normobaric pressure and hyperbaric pressures up...

  14. A novel stereoscopic projection display system for CT images of fractures.

    Science.gov (United States)

    Liu, Xiujuan; Jiang, Hong; Lang, Yuedong; Wang, Hongbo; Sun, Na

    2013-06-01

    The present study proposed a novel projection display system based on a virtual reality enhancement environment. The proposed system displays stereoscopic images of fractures and enhances the computed tomography (CT) images. The diagnosis and treatment of fractures primarily depend on the post-processing of CT images. However, two-dimensional (2D) images do not show overlapping structures in fractures since they are displayed without visual depth and these structures are too small to be simultaneously observed by a group of clinicians. Stereoscopic displays may solve this problem and allow clinicians to obtain more information from CT images. Hardware with which to generate stereoscopic images was designed. This system utilized the conventional equipment found in meeting rooms. The off-axis algorithm was adopted to convert the CT images into stereo image pairs, which were used as the input for a stereo generator. The final stereoscopic images were displayed using a projection system. Several CT fracture images were imported into the system for comparison with traditional 2D CT images. The results showed that the proposed system aids clinicians in group discussions by producing large stereoscopic images. The results demonstrated that the enhanced stereoscopic CT images generated by the system appear clearer and smoother, such that the sizes, displacement and shapes of bone fragments are easier to assess. Certain fractures that were previously not visible on 2D CT images due to vision overlap became vividly evident in the stereo images. The proposed projection display system efficiently, economically and accurately displayed three-dimensional (3D) CT images. The system may help clinicians improve the diagnosis and treatment of fractures.

  15. A preliminary study of CT imaging of water in a carnation flower

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, T.M. [Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1, Yayoi, Bunkyo-ku, Tokyo 113 (Japan); Furukawa, J. [Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1, Yayoi, Bunkyo-ku, Tokyo 113 (Japan); Matsubayashi, M. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki-ken 319-11 (Japan)

    1999-11-03

    We present the trial to determine the water deletion part in a carnation flower tissue while drying by neutron computer tomography (CT). The flower part was fixed on a rotating disk and thermal neutrons were irradiated for 4 s per projection. The total neutron dose was 6.0x10{sup 8} n/cm{sup 2} per projection. The neutrons penetrating the sample were converted to photons by a fluorescence converter. The photon image was guided to a cooled CCD camera using two mirrors. The sample was rotated, stepwise, every 1 deg. , up to 180 deg. , i.e. 180 images were obtained for the CT construction. Horizontal CT images of several slices of the flower were taken before and after the drying treatment. Vertical CT images of the flower were also constructed based on horizontal CT images. It was found that the water around the ovule was selectively removed by the drying treatment.

  16. A preliminary study of CT imaging of water in a carnation flower

    Science.gov (United States)

    Nakanishi, T. M.; Furukawa, J.; Matsubayashi, M.

    1999-11-01

    We present the trial to determine the water deletion part in a carnation flower tissue while drying by neutron computer tomography (CT). The flower part was fixed on a rotating disk and thermal neutrons were irradiated for 4 s per projection. The total neutron dose was 6.0×10 8 n/cm 2 per projection. The neutrons penetrating the sample were converted to photons by a fluorescence converter. The photon image was guided to a cooled CCD camera using two mirrors. The sample was rotated, stepwise, every 1°, up to 180°, i.e. 180 images were obtained for the CT construction. Horizontal CT images of several slices of the flower were taken before and after the drying treatment. Vertical CT images of the flower were also constructed based on horizontal CT images. It was found that the water around the ovule was selectively removed by the drying treatment.

  17. Cirrhosis: CT and MR imaging evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brancatelli, Giuseppe [Sezione di Radiologia, Ospedale Specializzato in Gastroenterologia, ' Saverio de Bellis' -IRCCS, 70013 Castellana Grotte (Bari) (Italy) and Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy) and Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States)]. E-mail: gbranca@yahoo.com; Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States); Ambrosini, Roberta [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Lagalla, Roberto [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Carriero, Alessandro [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Midiri, Massimo [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Vilgrain, Valerie [Service de Radiologie, Hopital Beaujon, 100 Boulevard du General Leclerc, 92118 Clichy (France)

    2007-01-15

    In this article, we present the CT and MR imaging characteristics of the cirrhotic liver. We describe the altered liver morphology in different forms of viral, alcoholic and autoimmune end-stage liver disease. We present the spectrum of imaging findings in portal hypertension, such as splenomegaly, ascites and varices. We describe the patchy and lacelike patterns of fibrosis, along with the focal confluent form. The process of hepatocarcinogenesis is detailed, from regenerative to dysplastic nodules to overt hepatocellular carcinoma. Different types of non-neoplastic focal liver lesions occurring in the cirrhotic liver are discussed, including arterially enhancing nodules, hemangiomas and peribiliary cysts. We show different conditions causing liver morphology changes that can mimic cirrhosis, such as congenital hepatic fibrosis, 'pseudo-cirrhosis' due to breast metastases treated with chemotherapy, Budd-Chiari syndrome, sarcoidosis and cavernous transformation of the portal vein.

  18. Abdominal wall hernias: imaging with spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G. [Department of Radiology, Bari University Hospital (Italy)

    2000-06-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  19. The influence of respiratory motion on CT image volume definition

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Romero, Ruth, E-mail: rrromero@salud.madrid.org; Castro-Tejero, Pablo, E-mail: pablo.castro@salud.madrid.org [Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Puerta de Hierro Majadahonda, 28222 Madrid (Spain)

    2014-04-15

    Purpose: Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). Methods: A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. Results: 4DCT acquisitions provided volume and position accuracies within ±3% and ±2 mm for structure dimensions >2 cm, breath amplitude ≤15 mm, and breath period ≥3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath

  20. The influence of respiratory motion on CT image volume definition.

    Science.gov (United States)

    Rodríguez-Romero, Ruth; Castro-Tejero, Pablo

    2014-04-01

    Radiotherapy treatments are based on geometric and density information acquired from patient CT scans. It is well established that breathing motion during scan acquisition induces motion artifacts in CT images, which can alter the size, shape, and density of a patient's anatomy. The aim of this work is to examine and evaluate the impact of breathing motion on multislice CT imaging with respiratory synchronization (4DCT) and without it (3DCT). A specific phantom with a movable insert was used. Static and dynamic phantom acquisitions were obtained with a multislice CT. Four sinusoidal breath patterns were simulated to move known geometric structures longitudinally. Respiratory synchronized acquisitions (4DCT) were performed to generate images during inhale, intermediate, and exhale phases using prospective and retrospective techniques. Static phantom data were acquired in helical and sequential mode to define a baseline for each type of respiratory 4DCT technique. Taking into account the fact that respiratory 4DCT is not always available, 3DCT helical image studies were also acquired for several CT rotation periods. To study breath and acquisition coupling when respiratory 4DCT was not performed, the beginning of the CT image acquisition was matched with inhale, intermediate, or exhale respiratory phases, for each breath pattern. Other coupling scenarios were evaluated by simulating different phantom and CT acquisition parameters. Motion induced variations in shape and density were quantified by automatic threshold volume generation and Dice similarity coefficient calculation. The structure mass center positions were also determined to make a comparison with their theoretical expected position. 4DCT acquisitions provided volume and position accuracies within ± 3% and ± 2 mm for structure dimensions >2 cm, breath amplitude ≤ 15 mm, and breath period ≥ 3 s. The smallest object (1 cm diameter) exceeded 5% volume variation for the breath patterns of higher

  1. Utilizing Astrometric Orbits to Obtain Coronagraphic Images

    CERN Document Server

    Davidson, John M

    2010-01-01

    We present an approach for utilizing astrometric orbit information to improve the yield of planetary images and spectra from a follow-on direct detection mission. This approach is based on the notion-strictly hypothetical-that if a particular star could be observed continuously, the instrument would in time observe all portions of the habitable zone so that no planet residing therein could be missed. This strategy could not be implemented in any realistic mission scenario. But if an exoplanet's orbit is known from astrometric observation, then it may be possible to plan and schedule a sequence of imaging observations that is the equivalent of continuous observation. A series of images-optimally spaced in time-could be recorded to examine contiguous segments of the orbit. In time, all segments would be examined, leading to the inevitable detection of the planet. In this paper, we show how astrometric orbit information can be used to construct such a sequence. Using stars from astrometric and imaging target lis...

  2. Cardiac CT Imaging of Plaque Vulnerability : Hype or Hope?

    NARCIS (Netherlands)

    Willemink, Martin J.; Leiner, Tim; Maurovich-Horvat, Pál

    2016-01-01

    Advances in cardiovascular computed tomography (CT) have resulted in an excellent ability to exclude coronary heart disease (CHD). Anatomical information, functional information, and spectral information can already be obtained with current CT technologies. Moreover, novel developments such as targe

  3. Cardiac CT Imaging of Plaque Vulnerability : Hype or Hope?

    NARCIS (Netherlands)

    Willemink, Martin J.; Leiner, Tim; Maurovich-Horvat, Pál

    2016-01-01

    Advances in cardiovascular computed tomography (CT) have resulted in an excellent ability to exclude coronary heart disease (CHD). Anatomical information, functional information, and spectral information can already be obtained with current CT technologies. Moreover, novel developments such as targe

  4. Neural network and its application to CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nikravesh, M.; Kovscek, A.R.; Patzek, T.W. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-02-01

    We present an integrated approach to imaging the progress of air displacement by spontaneous imbibition of oil into sandstone. We combine Computerized Tomography (CT) scanning and neural network image processing. The main aspects of our approach are (I) visualization of the distribution of oil and air saturation by CT, (II) interpretation of CT scans using neural networks, and (III) reconstruction of 3-D images of oil saturation from the CT scans with a neural network model. Excellent agreement between the actual images and the neural network predictions is found.

  5. An approach for quantitative image quality analysis for CT

    Science.gov (United States)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  6. Pitfalls and Limitations of PET/CT in Brain Imaging.

    Science.gov (United States)

    Salmon, Eric; Bernard Ir, Claire; Hustinx, Roland

    2015-11-01

    Neurologic applications were at the forefront of PET imaging when the technique was developed in the mid-1970s. Although oncologic indications have become prominent in terms of number of studies performed worldwide, neurology remains a major field in which functional imaging provides unique information, both for clinical and research purposes. The evaluation of glucose metabolism using FDG remains the most frequent exploration, but in recent years, alternative radiotracers have been developed, including fluorinated amino acid analogues for primary brain tumor imaging and fluorinated compounds for assessing the amyloid deposits in patients with suspected Alzheimer disease. As the brain is enclosed in the skull, which presents fixed landmarks, it is relatively easy to coregister images obtained with various cross-sectional imaging methods, either functional or anatomical, with a relatively high accuracy and robustness. Nevertheless, PET in neurology has fully benefited from the advent of hybrid imaging. Attenuation and scatter correction is now much faster and equally accurate, using CT as compared with the traditional transmission scan using an external radioactive source. The perfect coregistration with the CT data, which is now systematically performed, also provides its own set of valuable information, for instance regarding cerebral atrophy. However, hybrid imaging in neurology comes with pitfalls and limitations, in addition to those that are well known, for example, blood glucose levels or psychotropic drugs that greatly affect the physiological FDG uptake. Movements of the patient's head, either during the PET acquisition or between the PET and the CT acquisitions will generate artifacts that may be very subtle yet lead to erroneous interpretation of the study. Similarly, quantitative analysis, such as voxel-based analyses, may prove very helpful in improving the diagnostic accuracy and the reproducibility of the reading, but a wide variety of artifacts may

  7. Automated vertebra identification in CT images

    Science.gov (United States)

    Ehm, Matthias; Klinder, Tobias; Kneser, Reinhard; Lorenz, Cristian

    2009-02-01

    In this paper, we describe and compare methods for automatically identifying individual vertebrae in arbitrary CT images. The identification is an essential precondition for a subsequent model-based segmentation, which is used in a wide field of orthopedic, neurological, and oncological applications, e.g., spinal biopsies or the insertion of pedicle screws. Since adjacent vertebrae show similar characteristics, an automated labeling of the spine column is a very challenging task, especially if no surrounding reference structures can be taken into account. Furthermore, vertebra identification is complicated due to the fact that many images are bounded to a very limited field of view and may contain only few vertebrae. We propose and evaluate two methods for automatically labeling the spine column by evaluating similarities between given models and vertebral objects. In one method, object boundary information is taken into account by applying a Generalized Hough Transform (GHT) for each vertebral object. In the other method, appearance models containing mean gray value information are registered to each vertebral object using cross and local correlation as similarity measures for the optimization function. The GHT is advantageous in terms of computational performance but cuts back concerning the identification rate. A correct labeling of the vertebral column has been successfully performed on 93% of the test set consisting of 63 disparate input images using rigid image registration with local correlation as similarity measure.

  8. Spectral Reconstruction for Obtaining Virtual Hyperspectral Images

    Science.gov (United States)

    Perez, G. J. P.; Castro, E. C.

    2016-12-01

    Hyperspectral sensors demonstrated its capabalities in identifying materials and detecting processes in a satellite scene. However, availability of hyperspectral images are limited due to the high development cost of these sensors. Currently, most of the readily available data are from multi-spectral instruments. Spectral reconstruction is an alternative method to address the need for hyperspectral information. The spectral reconstruction technique has been shown to provide a quick and accurate detection of defects in an integrated circuit, recovers damaged parts of frescoes, and it also aids in converting a microscope into an imaging spectrometer. By using several spectral bands together with a spectral library, a spectrum acquired by a sensor can be expressed as a linear superposition of elementary signals. In this study, spectral reconstruction is used to estimate the spectra of different surfaces imaged by Landsat 8. Four atmospherically corrected surface reflectance from three visible bands (499 nm, 585 nm, 670 nm) and one near-infrared band (872 nm) of Landsat 8, and a spectral library of ground elements acquired from the United States Geological Survey (USGS) are used. The spectral library is limited to 420-1020 nm spectral range, and is interpolated at one nanometer resolution. Singular Value Decomposition (SVD) is used to calculate the basis spectra, which are then applied to reconstruct the spectrum. The spectral reconstruction is applied for test cases within the library consisting of vegetation communities. This technique was successful in reconstructing a hyperspectral signal with error of less than 12% for most of the test cases. Hence, this study demonstrated the potential of simulating information at any desired wavelength, creating a virtual hyperspectral sensor without the need for additional satellite bands.

  9. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  10. High-Dynamic-Range CT Reconstruction Based on Varying Tube-Voltage Imaging

    Science.gov (United States)

    2015-01-01

    For complicated structural components characterized by wide X-ray attenuation ranges, the conventional computed tomography (CT) imaging using a single tube-voltage at each rotation angle cannot obtain all structural information. This limitation results in a shortage of CT information, because the effective thickness of the components along the direction of X-ray penetration exceeds the limitation of the dynamic range of the X-ray imaging system. To address this problem, high-dynamic-range CT (HDR-CT) reconstruction is proposed. For this new method, the tube’s voltage is adjusted several times to match the corresponding effective thickness about the local information from an object. Then, HDR fusion and HDR-CT are applied to obtain the full reconstruction information. An accompanying experiment demonstrates that this new technology can extend the dynamic range of X-ray imaging systems and provide the complete internal structures of complicated structural components. PMID:26544723

  11. High-Dynamic-Range CT Reconstruction Based on Varying Tube-Voltage Imaging.

    Directory of Open Access Journals (Sweden)

    Ping Chen

    Full Text Available For complicated structural components characterized by wide X-ray attenuation ranges, the conventional computed tomography (CT imaging using a single tube-voltage at each rotation angle cannot obtain all structural information. This limitation results in a shortage of CT information, because the effective thickness of the components along the direction of X-ray penetration exceeds the limitation of the dynamic range of the X-ray imaging system. To address this problem, high-dynamic-range CT (HDR-CT reconstruction is proposed. For this new method, the tube's voltage is adjusted several times to match the corresponding effective thickness about the local information from an object. Then, HDR fusion and HDR-CT are applied to obtain the full reconstruction information. An accompanying experiment demonstrates that this new technology can extend the dynamic range of X-ray imaging systems and provide the complete internal structures of complicated structural components.

  12. Static and dynamic CT imaging of the cervical spine in patients with rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Soederman, Tomas; Shalabi, Adel; Sundin, Anders [Uppsala University Hospital, Department of Radiology, Uppsala (Sweden); Olerud, Claes; Alavi, Kamran [Uppsala University Hospital, Department of Orthopedic Surgery, Uppsala (Sweden)

    2014-09-18

    To compare CR with CT (static and dynamic) to evaluate upper spine instability and to determine if CT in flexion adds value compared to MR imaging in neutral position to assess compression of the subarachnoid space and of the spinal cord. Twenty-one consecutive patients with atlantoaxial subluxation due to rheumatoid arthritis planned for atlantoaxial fusion were included. CT and MRI were performed with the neck in the neutral position and CT also in flexion. CR in neutral position and flexion were obtained in all patients except for one subject who underwent examination in flexion and extension. CR and CT measurements of atlantoaxial subluxation correlated but were larger by CR than CT in flexion, however, the degree of vertical dislocation was similar with both techniques irrespective of the position of the neck. Cervical motion was larger at CR than at CT. The spinal cord compression was significantly worse at CT obtained in the flexed position as compared to MR imaging in the neutral position. Functional CR remains the primary imaging method but CT in the flexed position might be useful in the preoperative imaging work-up, as subarachnoid space involvement may be an indicator for the development of neurologic dysfunction. (orig.)

  13. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; von Schulthess, Gustav K.; Buck, Alfred [Division of Nuclear Medicine, Department of Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    Germanium-68 based attenuation correction (PET{sub Ge68}) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET{sub CT}) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET{sub Ge68} and PET{sub CT}. Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET{sub CT} in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET{sub Ge68} images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET{sub Ge68} and PET{sub CT} images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional {sup 68}Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the

  14. Comparison of stroke infarction between CT perfusion and diffusion weighted imaging: preliminary results

    Science.gov (United States)

    Abd. Rahni, Ashrani Aizzuddin; Arka, Israna Hossain; Chellappan, Kalaivani; Mukari, Shahizon Azura; Law, Zhe Kang; Sahathevan, Ramesh

    2016-03-01

    In this paper we present preliminary results of comparison of automatic segmentations of the infarct core, between that obtained from CT perfusion (based on time to peak parameter) and diffusion weighted imaging (DWI). For each patient, the two imaging volumes were automatically co-registered to a common frame of reference based on an acquired CT angiography image. The accuracy of image registration is measured by the overlap of the segmented brain from both images (CT perfusion and DWI), measured within their common field of view. Due to the limitations of the study, DWI was acquired as a follow up scan up to a week after initial CT based imaging. However, we found significant overlap of the segmented brain (Jaccard indices of approximately 0.8) and the percentage of infarcted brain tissue from the two modalities were still fairly highly correlated (correlation coefficient of approximately 0.9). The results are promising with more data needed in future for clinical inference.

  15. Automatic segmentation of lumbar vertebrae in CT images

    Science.gov (United States)

    Kulkarni, Amruta; Raina, Akshita; Sharifi Sarabi, Mona; Ahn, Christine S.; Babayan, Diana; Gaonkar, Bilwaj; Macyszyn, Luke; Raghavendra, Cauligi

    2017-03-01

    Lower back pain is one of the most prevalent disorders in the developed/developing world. However, its etiology is poorly understood and treatment is often determined subjectively. In order to quantitatively study the emergence and evolution of back pain, it is necessary to develop consistently measurable markers for pathology. Imaging based measures offer one solution to this problem. The development of imaging based on quantitative biomarkers for the lower back necessitates automated techniques to acquire this data. While the problem of segmenting lumbar vertebrae has been addressed repeatedly in literature, the associated problem of computing relevant biomarkers on the basis of the segmentation has not been addressed thoroughly. In this paper, we propose a Random-Forest based approach that learns to segment vertebral bodies in CT images followed by a biomarker evaluation framework that extracts vertebral heights and widths from the segmentations obtained. Our dataset consists of 15 CT sagittal scans obtained from General Electric Healthcare. Our main approach is divided into three parts: the first stage is image pre-processing which is used to correct for variations in illumination across all the images followed by preparing the foreground and background objects from images; the next stage is Machine Learning using Random-Forests, which distinguishes the interest-point vectors between foreground or background; and the last step is image post-processing, which is crucial to refine the results of classifier. The Dice coefficient was used as a statistical validation metric to evaluate the performance of our segmentations with an average value of 0.725 for our dataset.

  16. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline

    Institute of Scientific and Technical Information of China (English)

    DENG Biao; YANG Qun; XIE Hong-Lan; DU Guo-Hao; XIAO Wi-Qiao

    2011-01-01

    X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF X-ray imaging beamline (BL13W1) are described. The test samples were investigated and the 2D elemental image was reconstructed using a filtered back-projection algorithm. In the sample the element Cd was observed. Up to now, the X-ray fluorescence CT could be carried out at the SSRF X-ray imaging beamline.

  17. AAPM/RSNA physics tutorial for residents: topics in CT. Image processing in CT.

    Science.gov (United States)

    Cody, Dianna D

    2002-01-01

    Several image-processing methods for computed tomographic (CT) examinations are currently being used in clinical radiology departments. Image processing involves operations such as reformatting of original CT images, volume-rendered displays, surface-rendered displays, and physiologic imaging analysis. The reformatting process does not alter the CT voxels in any way; instead it uses them in off-axis views and displays the images produced from the original reconstruction process in an orientation other than how they were originally generated. Sagittal, coronal, oblique, and curved reformatting are standard reformatting methods. Other reformatting techniques include maximum-intensity projection, minimum-intensity projection, and variable thickness viewing. Volume and surface rendering are two different methods for reformatting axial images into three-dimensional views. CT perfusion allows the measurement of physiologic parameters over time. Additional postprocessing efforts can potentially add value to the patients and their outcomes, as can be seen in the cases that illustrate this article.

  18. Personal computer aided cerebral perfusion imaging with dynamic CT

    Institute of Scientific and Technical Information of China (English)

    林燕; 高培毅

    2004-01-01

    @@Reports on the clinical implementation of dynamic computerised tomography (CT) perfusion imaging and quantitative measurement have increased dramatically of late.1-8 The advantages of dynamic CT perfusion imaging and quantitative measurement for the diagnosis of acute cerebral infarction have been acknowledged. However, most overseas CT vendors set perfusion imaging software package as an option for graphic workstation at a too high price for domestic practitioners. To foster the domestic implementation and development of this new technology, we have extended the earlier work.1,2 Applying the theory of central volume principle to DICOM 3.0 standard forms of prime CT images, we developed dynamic CT perfusion imaging and quantitative measure-ment programmes for PCs using Visual C+ + in Windows 98 system.

  19. Fast CT-CT fluoroscopy registration with respiratory motion compensation for image-guided lung intervention

    Science.gov (United States)

    Su, Po; Xue, Zhong; Lu, Kongkuo; Yang, Jianhua; Wong, Stephen T.

    2012-02-01

    CT-fluoroscopy (CTF) is an efficient imaging method for guiding percutaneous lung interventions such as biopsy. During CTF-guided biopsy procedure, four to ten axial sectional images are captured in a very short time period to provide nearly real-time feedback to physicians, so that they can adjust the needle as it is advanced toward the target lesion. Although popularly used in clinics, this traditional CTF-guided intervention procedure may require frequent scans and cause unnecessary radiation exposure to clinicians and patients. In addition, CTF only generates limited slices of images and provides limited anatomical information. It also has limited response to respiratory movements and has narrow local anatomical dynamics. To better utilize CTF guidance, we propose a fast CT-CTF registration algorithm with respiratory motion estimation for image-guided lung intervention using electromagnetic (EM) guidance. With the pre-procedural exhale and inhale CT scans, it would be possible to estimate a series of CT images of the same patient at different respiratory phases. Then, once a CTF image is captured during the intervention, our algorithm can pick the best respiratory phase-matched 3D CT image and performs a fast deformable registration to warp the 3D CT toward the CTF. The new 3D CT image can be used to guide the intervention by superimposing the EM-guided needle location on it. Compared to the traditional repetitive CTF guidance, the registered CT integrates both 3D volumetric patient data and nearly real-time local anatomy for more effective and efficient guidance. In this new system, CTF is used as a nearly real-time sensor to overcome the discrepancies between static pre-procedural CT and the patient's anatomy, so as to provide global guidance that may be supplemented with electromagnetic (EM) tracking and to reduce the number of CTF scans needed. In the experiments, the comparative results showed that our fast CT-CTF algorithm can achieve better registration

  20. Classification of CT brain images based on deep learning networks.

    Science.gov (United States)

    Gao, Xiaohong W; Hui, Rui; Tian, Zengmin

    2017-01-01

    While computerised tomography (CT) may have been the first imaging tool to study human brain, it has not yet been implemented into clinical decision making process for diagnosis of Alzheimer's disease (AD). On the other hand, with the nature of being prevalent, inexpensive and non-invasive, CT does present diagnostic features of AD to a great extent. This study explores the significance and impact on the application of the burgeoning deep learning techniques to the task of classification of CT brain images, in particular utilising convolutional neural network (CNN), aiming at providing supplementary information for the early diagnosis of Alzheimer's disease. Towards this end, three categories of CT images (N = 285) are clustered into three groups, which are AD, lesion (e.g. tumour) and normal ageing. In addition, considering the characteristics of this collection with larger thickness along the direction of depth (z) (~3-5 mm), an advanced CNN architecture is established integrating both 2D and 3D CNN networks. The fusion of the two CNN networks is subsequently coordinated based on the average of Softmax scores obtained from both networks consolidating 2D images along spatial axial directions and 3D segmented blocks respectively. As a result, the classification accuracy rates rendered by this elaborated CNN architecture are 85.2%, 80% and 95.3% for classes of AD, lesion and normal respectively with an average of 87.6%. Additionally, this improved CNN network appears to outperform the others when in comparison with 2D version only of CNN network as well as a number of state of the art hand-crafted approaches. As a result, these approaches deliver accuracy rates in percentage of 86.3, 85.6 ± 1.10, 86.3 ± 1.04, 85.2 ± 1.60, 83.1 ± 0.35 for 2D CNN, 2D SIFT, 2D KAZE, 3D SIFT and 3D KAZE respectively. The two major contributions of the paper constitute a new 3-D approach while applying deep learning technique to extract signature information

  1. Dual energy CT: New horizon in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Goo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  2. Dual-Energy CT: New Horizon in Medical Imaging.

    Science.gov (United States)

    Goo, Hyun Woo; Goo, Jin Mo

    2017-01-01

    Dual-energy CT has remained underutilized over the past decade probably due to a cumbersome workflow issue and current technical limitations. Clinical radiologists should be made aware of the potential clinical benefits of dual-energy CT over single-energy CT. To accomplish this aim, the basic principle, current acquisition methods with advantages and disadvantages, and various material-specific imaging methods as clinical applications of dual-energy CT should be addressed in detail. Current dual-energy CT acquisition methods include dual tubes with or without beam filtration, rapid voltage switching, dual-layer detector, split filter technique, and sequential scanning. Dual-energy material-specific imaging methods include virtual monoenergetic or monochromatic imaging, effective atomic number map, virtual non-contrast or unenhanced imaging, virtual non-calcium imaging, iodine map, inhaled xenon map, uric acid imaging, automatic bone removal, and lung vessels analysis. In this review, we focus on dual-energy CT imaging including related issues of radiation exposure to patients, scanning and post-processing options, and potential clinical benefits mainly to improve the understanding of clinical radiologists and thus, expand the clinical use of dual-energy CT; in addition, we briefly describe the current technical limitations of dual-energy CT and the current developments of photon-counting detector.

  3. Description of patellar movement by 3D parameters obtained from dynamic CT acquisition

    Science.gov (United States)

    de Sá Rebelo, Marina; Moreno, Ramon Alfredo; Gobbi, Riccardo Gomes; Camanho, Gilberto Luis; de Ávila, Luiz Francisco Rodrigues; Demange, Marco Kawamura; Pecora, Jose Ricardo; Gutierrez, Marco Antonio

    2014-03-01

    The patellofemoral joint is critical in the biomechanics of the knee. The patellofemoral instability is one condition that generates pain, functional impairment and often requires surgery as part of orthopedic treatment. The analysis of the patellofemoral dynamics has been performed by several medical image modalities. The clinical parameters assessed are mainly based on 2D measurements, such as the patellar tilt angle and the lateral shift among others. Besides, the acquisition protocols are mostly performed with the leg laid static at fixed angles. The use of helical multi slice CT scanner can allow the capture and display of the joint's movement performed actively by the patient. However, the orthopedic applications of this scanner have not yet been standardized or widespread. In this work we present a method to evaluate the biomechanics of the patellofemoral joint during active contraction using multi slice CT images. This approach can greatly improve the analysis of patellar instability by displaying the physiology during muscle contraction. The movement was evaluated by computing its 3D displacements and rotations from different knee angles. The first processing step registered the images in both angles based on the femuŕs position. The transformation matrix of the patella from the images was then calculated, which provided the rotations and translations performed by the patella from its position in the first image to its position in the second image. Analysis of these parameters for all frames provided real 3D information about the patellar displacement.

  4. RONI Based Secured and Authenticated Indexing of Lung CT Images

    Directory of Open Access Journals (Sweden)

    I. Jasmine Selvakumari Jeya

    2015-01-01

    Full Text Available Medical images need to be transmitted with the patient’s information without altering the image data. The present paper discusses secured indexing of lung CT image (SILI which is a secured way of indexing the lung CT images with the patient information. Authentication is provided using the sender’s logo information and the secret key is used for embedding the watermark into the host image. Watermark is embedded into the region of Noninterest (RONI of the lung CT image. RONI is identified by segmenting the lung tissue from the CT scan image. The experimental results show that the proposed approach is robust against unauthorized access, noise, blurring, and intensity based attacks.

  5. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    Energy Technology Data Exchange (ETDEWEB)

    Won Kim, Chang [Interdisciplinary Program of Bioengineering Major Seoul National University College of Engineering, San 56-1, Silim-dong, Gwanak-gu, Seoul 152-742, South Korea and Institute of Radiation Medicine, Seoul National University College of Medicine, 28, Yongon-dong, Chongno-gu, Seoul 110-744 (Korea, Republic of); Kim, Jong Hyo, E-mail: kimjhyo@snu.ac.kr [Department of Radiology, Institute of Radiation Medicine, Seoul National University College of Medicine, 28, Yongon-dong, Chongno-gu, Seoul, 110-744 (Korea, Republic of); Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Suwon, Gyeonggi-do, 443-270 (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Suwon, Gyeonggi-do, 443-270 (Korea, Republic of)

    2014-01-15

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  6. A PRELIMINARY STUDY ON COMPARISON AND FUSION OF METABOLIC IMAGES OF PET WITH ANATOMIC IMAGES OF CT AND MRI

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective. To compare and match metabolic images of PET with anatomic images of CT and MRI. Methods. The CT or MRI images of the patients were obtained through a photo scanner, and then transferred to the remote workstation of PET scanner with a floppy disk. A fusion method was developed to match the 2-dimensional CT or MRI slices with the correlative slices of 3-dimensional volume PET images. Results. Twenty- nine metabolically changed foci were accurately localized in 21 epilepsy patients' MRI images, while MRI alone had only 6 true positive findings. In 53 cancer or suspicious cancer patients, 53 positive lesions detected by PET were compared and matched with the corresponding lesions in CT or MRI images, in which 10 lesions were missed. On the other hand, 23 lesions detected from the patients' CT or MRI images were negative or with low uptake in the PET images, and they were finally proved as benign. Conclusions. Comparing and matching metabolic images with anatomic images helped obtain a full understanding about the lesion and its peripheral structures. The fusion method was simple, practical and useful for localizing metabolically changed lesions.

  7. Quantitative image quality evaluation for cardiac CT reconstructions

    Science.gov (United States)

    Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.; Balhorn, William; Okerlund, Darin R.

    2016-03-01

    Maintaining image quality in the presence of motion is always desirable and challenging in clinical Cardiac CT imaging. Different image-reconstruction algorithms are available on current commercial CT systems that attempt to achieve this goal. It is widely accepted that image-quality assessment should be task-based and involve specific tasks, observers, and associated figures of merits. In this work, we developed an observer model that performed the task of estimating the percentage of plaque in a vessel from CT images. We compared task performance of Cardiac CT image data reconstructed using a conventional FBP reconstruction algorithm and the SnapShot Freeze (SSF) algorithm, each at default and optimal reconstruction cardiac phases. The purpose of this work is to design an approach for quantitative image-quality evaluation of temporal resolution for Cardiac CT systems. To simulate heart motion, a moving coronary type phantom synchronized with an ECG signal was used. Three different percentage plaques embedded in a 3 mm vessel phantom were imaged multiple times under motion free, 60 bpm, and 80 bpm heart rates. Static (motion free) images of this phantom were taken as reference images for image template generation. Independent ROIs from the 60 bpm and 80 bpm images were generated by vessel tracking. The observer performed estimation tasks using these ROIs. Ensemble mean square error (EMSE) was used as the figure of merit. Results suggest that the quality of SSF images is superior to the quality of FBP images in higher heart-rate scans.

  8. Feasibility study of CT perfusion imaging for prostate carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cullu, Nesat [Mugla Sitki Kocman University, School of Medicine, Department of Radiology, Mugla (Turkey); Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Kantarci, Mecit; Ogul, Hayri; Pirimoglu, Berhan; Karaca, Leyla; Kizrak, Yesim [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Adanur, Senol; Koc, Erdem; Polat, Ozkan [Atatuerk University, School of Medicine, Department of Urology, Erzurum (Turkey); Okur, Aylin [Atatuerk University, School of Medicine, Department of Radiology, Erzurum (Turkey); Bozok University, School of Medicine, Department of Radiology, Yozgat (Turkey)

    2014-09-15

    The aim of this feasibility study was to obtain initial data with which to assess the efficiency of perfusion CT imaging (CTpI) and to compare this with magnetic resonance imaging (MRI) in the diagnosis of prostate carcinoma. This prospective study involved 25 patients with prostate carcinoma undergoing MRI and CTpI. All analyses were performed on T2-weighted images (T2WI), apparent diffusion coefficient (ADC) maps, diffusion-weighted images (DWI) and CTp images. We compared the performance of T2WI combined with DWI and CTp alone. The study was approved by the local ethics committee, and written informed consent was obtained from all patients. Tumours were present in 87 areas according to the histopathological results. The diagnostic performance of the T2WI+DWI+CTpI combination was significantly better than that of T2WI alone for prostate carcinoma (P < 0.001). The diagnostic value of CTpI was similar to that of T2WI+DWI in combination. There were statistically significant differences in the blood flow and permeability surface values between prostate carcinoma and background prostate on CTp images. CTp may be a valuable tool for detecting prostate carcinoma and may be preferred in cases where MRI is contraindicated. If this technique is combined with T2WI and DWI, its diagnostic value is enhanced. (orig.)

  9. In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent

    Science.gov (United States)

    Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho

    2015-04-01

    In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.

  10. High Dose MicroCT Does Not Contribute Toward Improved MicroPET/CT Image Quantitative Accuracy and Can Limit Longitudinal Scanning of Small Animals

    Directory of Open Access Journals (Sweden)

    Wendy A. McDougald

    2017-10-01

    Full Text Available Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1 to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2 to evaluate the absorbed dose associated with varying CT parameters.Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA software implemented by Mediso. Measured Hounsfield Unit (HU in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC, uniformity and quantitative bias were also measured.Results: Only less than 2 and 1% of CT acquisition protocols yielded water HU values < −80 and air HU values < −840, respectively. Four out of 11 CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration.Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed toward improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  11. Clough-Tocher interpolation of virtual sinogram in a Delaunay triangulated grid for metal artifact reduction of PET/CT images

    NARCIS (Netherlands)

    Abdoli, M.; de Long, J. R.; Pruim, J.; Dierckx, R. A. J. O.; Zaidi, H.

    2011-01-01

    Metallic implants, such as hip implants, are known to induce streaking artifacts in CT images which can cause over/underestimation of the activity uptake in CT-based attenuation corrected PET images. Hence, metal artifact reduction (MAR) of CT images is essential in order to obtain accurate quantifi

  12. Robust cranial cavity segmentation in CT and CT perfusion images of trauma and suspected stroke patients

    NARCIS (Netherlands)

    Patel, A; Ginneken, B. van; Meijer, F.J.A.; Dijk, E.J. van; Prokop, M.; Manniesing, R.

    2017-01-01

    A robust and accurate method is presented for the segmentation of the cranial cavity in computed tomography (CT) and CT perfusion (CTP) images. The method consists of multi-atlas registration with label fusion followed by a geodesic active contour levelset refinement of the segmentation.

  13. Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, Jessen; Khan, M. Fawad; Maataoui, Adel; Herzog, C.; Vogl, Thomas J. [Johann Wolfgang Goethe University, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Bux, R.; Bratzke, H. [Johann Wolfgang Goethe University, Institute for Forensic Medicine, Frankfurt am Main (Germany); Ackermann, Hanns [Johann Wolfgang Goethe University, Institute for Epidemiology and Medical Statistics, Frankfurt am Main (Germany)

    2005-09-01

    To optimize examination protocols of 16-row multi-detector CT (MDCT) of pelvis for dose reduction with regard to image quality. MDCT of pelvis was performed on 12 cadaver specimens with stepwise reduction of tube current from 160 mA (113, 80, 56, 40, 28) to 20 mA at 120 kV. Scan parameters were 16 x 1.5 mm collimation. Reconstructions of axial and coronal images were used for evaluation of cortex, trabeculum, image quality, image noise, acetabulum and iliosacral (ISJ) joints. After data were blinded, evaluation of images was done by three radiologists according to 5-point Likert scale. Accuracy of the observers in sorting films according to dose reduction was determined with kappa coefficient. Mean values of image evaluation were determined. Pronounced deterioration of image quality for all criteria was observed between 80 and 28 mA. Adequate image quality was obtained at 40 mA [effective dose (E): 2.2 mSv, CTDI{sub w}: 2.8 mGy] for criterion detailed definition of acetabulum and ISJ and at 80 mA (E: 4.4 mSv, CTDI{sub w}: 5.6 mGy) for remaining criteria. Moderate agreement was observed between the three observers (kappa coefficient: 0.31). All observers were excellent in arranging images according to decreasing dose. Using 16-row MDCT image quality of pelvis is acceptable at 80 mA and 120 kV. This translates into a dose reduction of 33% of average value of the nationwide survey of the German Roentgen Society (1999) for this type of examination. (orig.)

  14. A New Method of CT MedicalImages Contrast Enhancement

    Institute of Scientific and Technical Information of China (English)

    SUNFeng-rong; LIUWei; WANGChang-yu; MEILiang-mo

    2004-01-01

    A new method of contrast enhancement is proposed in the paper using multiscale edge representation of images, and is applied to the field of CT medical image processing. Comparing to the traditional Window technique, our method is adaptive and meets the demand of radiology clinics more better. The clinical experiment results show the practicality and the potential applied value of our methodin the field of CT medical images contrast enhancement.

  15. Segmentation of the thoracic aorta in noncontrast cardiac CT images.

    Science.gov (United States)

    Avila-Montes, Olga C; Kurkure, Uday; Nakazato, Ryo; Berman, Daniel S; Dey, Damini; Kakadiaris, Ioannis A

    2013-09-01

    Studies have shown that aortic calcification is associated with cardiovascular disease. In this study, a method for localization, centerline extraction, and segmentation of the thoracic aorta in noncontrast cardiac-computed tomography (CT) images, toward the detection of aortic calcification, is presented. The localization of the right coronary artery ostium slice is formulated as a regression problem whose input variables are obtained from simple intensity features computed from a pyramid representation of the slice. The localization, centerline extraction, and segmentation of the aorta are formulated as optimal path detection problems. Dynamic programming is applied in the Hough space for localizing key center points in the aorta which guide the centerline tracing using a fast marching-based minimal path extraction framework. The input volume is then resampled into a stack of 2-D cross-sectional planes orthogonal to the obtained centerline. Dynamic programming is again applied for the segmentation of the aorta in each slice of the resampled volume. The obtained segmentation is finally mapped back to its original volume space. The performance of the proposed method was assessed on cardiac noncontrast CT scans and promising results were obtained.

  16. MR image-based synthetic CT for IMRT prostate treatment planning and CBCT image-guided localization.

    Science.gov (United States)

    Chen, Shupeng; Quan, Hong; Qin, An; Yee, Seonghwan; Yan, Di

    2016-05-08

    The purpose of this study was to propose and evaluate a method of creating a synthetic CT (S-CT) from MRI simulation for dose calculation and daily CBCT localization. A pair of MR and CT images was obtained in the same day from each of 10 prostate patients. The pair of MR and CT images was preregistered using the deformable image registration (DIR). Using the corresponding displacement vector field (atlas-DVF), the CT image was deformed to the MR image to create an atlas MR-CT pair. Regions of interest (ROI) on the atlas MR-CT pair were delineated and used to create atlas-ROI masks. 'Leave-one-out' test (one pair of MR and CT was used as subject-MR and subject-CT for evaluation, and the remaining 9 pairs were in the atlas library) was performed. For a subject-MR, autosegmentation and DVFs were generated using DIR between the subject-MR and the 9 atlas-MRs. An S-CT was then generated using the corresponding 9 paired atlas-CTs, the 9 atlas-DVFs and the corresponding atlas-ROI masks. The total 10 S-CTs were evaluated using the Hounsfield unit (HU), the calculated dose distribution, and the auto bony registration to daily CBCT images with respect to the 10 subject-CTs. HU differences (mean ± STD) were (2.4 ± 25.23), (1.18 ± 39.49), (32.46 ± 81.9), (0.23 ± 40.13), and (3.74 ± 144.76) for prostate, bladder, rectal wall, soft tissue outside all ROIs, and bone, respectively. The discrepancy of dose-volume param-eters calculated using the S-CT for treatment planning was small (≤ 0.22% with 95% confidence). Gamma pass rate (2% & 2 mm) was higher than 99.86% inside PTV and 98.45% inside normal structures. Using the 10 S-CTs as the reference CT for daily CBCT localization achieved the similar results compared to using the subject-CT. The translational vector differences were within 1.08 mm (0.37 ± 0.23 mm), and the rotational differences were within 1.1° in all three directions. S-CT created from a simulation MR image using the proposed approach with the

  17. SPECT/CT imaging in children with papillary thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E. [Cincinnati Children' s Hospital, Department of Radiology, Cincinnati, OH (United States)

    2011-08-15

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  18. Multimodal CT in stroke imaging: new concepts.

    Science.gov (United States)

    Ledezma, Carlos J; Wintermark, Max

    2009-01-01

    A multimodal CT protocol provides a comprehensive noninvasive survey of acute stroke patients with accurate demonstration of the site of arterial occlusion and its hemodynamic tissue status. It combines widespread availability with the ability to provide functional characterization of cerebral ischemia, and could potentially allow more accurate selection of candidates for acute stroke reperfusion therapy. This article discusses the individual components of multimodal CT and addresses the potential role of a combined multimodal CT stroke protocol in acute stroke therapy.

  19. Whole-brain dynamic CT angiography and perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orrison, W.W. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Department of Medical Education, University of Nevada School of Medicine, Reno, NV (United States); Snyder, K.V.; Hopkins, L.N. [Department of Neurosurgery, Millard Fillmore Gates Circle Hospital, Buffalo, NY (United States); Roach, C.J. [School of Life Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Ringdahl, E.N. [Department of Psychology, University of Nevada Las Vegas, Las Vegas, NV (United States); Nazir, R. [Shifa International Hospital, Islamabad (Pakistan); Hanson, E.H., E-mail: eric.hanson@amigenics.co [College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States)

    2011-06-15

    The availability of whole brain computed tomography (CT) perfusion has expanded the opportunities for analysing the haemodynamic parameters associated with varied neurological conditions. Examples demonstrating the clinical utility of whole-brain CT perfusion imaging in selected acute and chronic ischaemic arterial neurovascular conditions are presented. Whole-brain CT perfusion enables the detection and focused haemodynamic analyses of acute and chronic arterial conditions in the central nervous system without the limitation of partial anatomical coverage of the brain.

  20. Automated Selection of Uniform Regions for CT Image Quality Detection

    CERN Document Server

    Naeemi, Maitham D; Roychodhury, Sohini

    2016-01-01

    CT images are widely used in pathology detection and follow-up treatment procedures. Accurate identification of pathological features requires diagnostic quality CT images with minimal noise and artifact variation. In this work, a novel Fourier-transform based metric for image quality (IQ) estimation is presented that correlates to additive CT image noise. In the proposed method, two windowed CT image subset regions are analyzed together to identify the extent of variation in the corresponding Fourier-domain spectrum. The two square windows are chosen such that their center pixels coincide and one window is a subset of the other. The Fourier-domain spectral difference between these two sub-sampled windows is then used to isolate spatial regions-of-interest (ROI) with low signal variation (ROI-LV) and high signal variation (ROI-HV), respectively. Finally, the spatial variance ($var$), standard deviation ($std$), coefficient of variance ($cov$) and the fraction of abdominal ROI pixels in ROI-LV ($\

  1. Functional imaging of the lung by CT und MRI; Funktionelle Lungendiagnostik mit CT und MRT

    Energy Technology Data Exchange (ETDEWEB)

    Puderbach, M.; Eichinger, M.; Kauczor, H.U. [Deutsches Krebsforschungsinstitut Heidelberg (Germany). Abt. Radiologie

    2005-06-01

    Imaging techniques are indispensable for diagnosis and follow-up of pulmonary diseases. In the past the interest was focused on morphological aspects of pulmonary tissue. With the development of novel CT and MRI techniques functional pulmonary imaging became available. In this review the value of cross sectional functional imaging in pulmonary diseases is presented and its potential clinical applications are discussed. (orig.)

  2. IMAGE RECONSTRUCTION AND OBJECT CLASSIFICATION IN CT IMAGING SYSTEM

    Institute of Scientific and Technical Information of China (English)

    张晓明; 蒋大真; 等

    1995-01-01

    By obtaining a feasible filter function,reconstructed images can be got with linear interpolation and filtered backoprojection techniques.Considering the gray and spatial correlation neighbour informations of each pixel,a new supervised classification method is put forward for the reconstructed images,and an experiment with noise image is done,the result shows that the method is feasible and accurate compared with ideal phantoms.

  3. Can Spectral CT Imaging Improve the Differentiation between Malignant and Benign Solitary Pulmonary Nodules?

    Science.gov (United States)

    Hua, Xiaolan; Yu, Mingji; Xu, Chengdong; Zhang, Feng; Xu, Jianrong; Wu, Huawei

    2016-01-01

    Purpose To quantitatively assess the value of dual-energy CT (DECT) in differentiating malignancy and benignity of solitary pulmonary nodules. Materials and Methods Sixty-three patients with solitary pulmonary nodules detected by CT plain scan underwent contrast enhanced CT scans in arterial phase (AP) and venous phase (VP) with spectral imaging mode for tumor type differentiation. The Gemstone Spectral Imaging (GSI) viewer was used for image display and data analysis. Region of interest was placed on the relatively homogeneous area of the nodule to measure iodine concentration (IC) on iodine-based material decomposition images and CT numbers on monochromatic image sets to generate spectral HU curve. Normalized IC (NIC), slope of the spectral HU curve (λHU) and net CT number enhancement on 70keV images were calculated. The two-sample t-test was used to compare quantitative parameters. Receiver operating characteristic curves were generated to calculate sensitivity and specificity. Results There were 63 nodules, with 37 malignant nodules (59%) and 26 benign nodules (41%). NIC, λHU and net CT number enhancement on 70keV images for malignant nodules were all greater than those of benign nodules. NIC and λHU had intermediate to high performances to differentiate malignant nodules from benign ones with the areas under curve of 0.89 and 0.86 respectively in AP, 0.96 and 0.89 respectively in VP. Using 0.30 as a threshold value for NIC in VP, one could obtain sensitivity of 93.8% and specificity of 85.7% for differentiating malignant from benign solitary pulmonary nodules. These values were statistically higher than the corresponding values of 74.2% and 53.8% obtained with the conventional CT number enhancement. Conclusions DECT imaging with GSI mode provides more promising value in quantitative way for distinguishing malignant nodules from benign ones than CT enhancement numbers. PMID:26840459

  4. Can Spectral CT Imaging Improve the Differentiation between Malignant and Benign Solitary Pulmonary Nodules?

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    Full Text Available To quantitatively assess the value of dual-energy CT (DECT in differentiating malignancy and benignity of solitary pulmonary nodules.Sixty-three patients with solitary pulmonary nodules detected by CT plain scan underwent contrast enhanced CT scans in arterial phase (AP and venous phase (VP with spectral imaging mode for tumor type differentiation. The Gemstone Spectral Imaging (GSI viewer was used for image display and data analysis. Region of interest was placed on the relatively homogeneous area of the nodule to measure iodine concentration (IC on iodine-based material decomposition images and CT numbers on monochromatic image sets to generate spectral HU curve. Normalized IC (NIC, slope of the spectral HU curve (λHU and net CT number enhancement on 70keV images were calculated. The two-sample t-test was used to compare quantitative parameters. Receiver operating characteristic curves were generated to calculate sensitivity and specificity.There were 63 nodules, with 37 malignant nodules (59% and 26 benign nodules (41%. NIC, λHU and net CT number enhancement on 70keV images for malignant nodules were all greater than those of benign nodules. NIC and λHU had intermediate to high performances to differentiate malignant nodules from benign ones with the areas under curve of 0.89 and 0.86 respectively in AP, 0.96 and 0.89 respectively in VP. Using 0.30 as a threshold value for NIC in VP, one could obtain sensitivity of 93.8% and specificity of 85.7% for differentiating malignant from benign solitary pulmonary nodules. These values were statistically higher than the corresponding values of 74.2% and 53.8% obtained with the conventional CT number enhancement.DECT imaging with GSI mode provides more promising value in quantitative way for distinguishing malignant nodules from benign ones than CT enhancement numbers.

  5. SPECT/CT 90Y-Bremsstrahlung images for dosimetry during therapy

    OpenAIRE

    Fabbri, C.; Sarti, G.; Agostini, M; Di Dia, A; Paganelli, G

    2008-01-01

    Background: the characteristics of 90Y, suitable for therapy, are denoted by the lack of γ-emission. Alternative methods, using analogues labelled with 111In or 86Y, are generally applied to image 90Y-conjugates, with some inevitable drawbacks. New generation SPECT/CT image systems offer improved Bremsstrahlung images. The intent of this brief communication is to show that high quality 90Y-Bremsstrahlung SPECT-CT images can be obtained, allowing the biodistribution of pure β-emitter therapeut...

  6. Atlas image labeling of subcortical structures and vascular territories in brain CT images.

    Science.gov (United States)

    Du, Kaifang; Zhang, Li; Nguyen, Tony; Ordy, Vincent; Fichte, Heinz; Ditt, Hendrik; Chefd'hotel, Christophe

    2013-01-01

    We propose a multi-atlas labeling method for subcortical structures and cerebral vascular territories in brain CT images. Each atlas image is registered to the query image by a non-rigid registration and the deformation is then applied to the labeling of the atlas image to obtain the labeling of the query image. Four label fusion strategies (single atlas, most similar atlas, major voting, and STAPLE) were compared. Image similarity values in non-rigid registration were calculated and used to select and rank atlases. Major voting fusion strategy gave the best accuracy, with DSC (Dice similarity coefficient) around 0.85 ± 0.03 for caudate, putamen, and thalamus. The experimental results also show that fusing more atlases does not necessarily yield higher accuracy and we should be able to improve accuracy and decrease computation cost at the same time by selecting a preferred set with the minimum number of atlases.

  7. Fusion of intravenous contrast-enhanced C-arm CT and pretreatment imaging for ablation margin assessment of liver tumors: A preliminary study

    Directory of Open Access Journals (Sweden)

    Jin Iwazawa

    2012-01-01

    Full Text Available The aim of this preliminary study was to evaluate the feasibility of assessing ablation margins after radiofrequency ablation (RFA of liver tumors from fusion images of post-treatment C-arm computed tomography (CT images fused to pretreatment images. Five patients with liver tumors underwent RFA. Intravenous contrast-enhanced C-arm CT images were obtained for all patients immediately after RFA, and multi-detector CT (MDCT images were obtained 3-7 days later. The C-arm CT and MDCT images were fused to pretreatment images using a multimodality image fusion software. The minimum ablation margins were assessed in the C-arm CT and MDCT fusion images. Ablation margins after RFA of liver tumors can be measured using intravenous contrast-enhanced C-arm CT images fused with pretreatment images. This technique has the potential for use in the intra-procedural assessment of liver tumor ablation.

  8. Investigation of the LabPET™ detector and electronics for photon-counting CT imaging

    Science.gov (United States)

    Bérard, Philippe; Riendeau, Joel; Pepin, Catherine M.; Rouleau, Daniel; Cadorette, Jules; Fontaine, Réjean; Lecomte, Roger

    2007-02-01

    The development of new molecular probes targeting receptors with high specificity in selected cells and tissues highlights the importance of obtaining the anatomical context in Positron Emission Tomography (PET) imaging. This can be achieved using another imaging modality, such as X-ray Computed Tomography (CT) or Magnetic Resonance Imaging (MRI), but the anatomic and molecular images obtained sequentially with different scanners must subsequently be co-registered and are subjected to motion artifacts. Conventional CT imaging also contributes a significant dose, which may compromise the benefits of longitudinal molecular imaging studies in the same subject. To overcome these difficulties, we have investigated the use of the LabPET™ detector and electronics as a multi-modal detection system. Based on fast light emitting inorganic scintillators individually coupled to avalanche photodiodes and parallel, low-noise, fast digital processing electronics, the proposed detector front-end is suitable for coincidence detection of annihilation radiation (511 keV) in PET and for ultra-fast low-energy X-ray photon counting in CT. This combined detection system enables concurrent PET/CT imaging while potentially achieving superior image contrast sensitivity for a given dose in CT photon-counting mode. Anatomical images with millimeter spatial resolution and sufficient tissue contrast for anatomical localization in small animals have been obtained with doses in the mGy range. The CT performance for dual-modality imaging of small animals was analyzed in terms of spatial resolution, noise and image contrast sensitivity as a function of dose.

  9. A single CdZnTe detector for simultaneous CT/SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Barber, W.C. E-mail: bill@barber.uscf.edu; Iwata, Koji; Hasegawa, B.H.; Bennett, P.R.; Cirignano, L.J.; Shah, K.S

    2003-06-01

    Clinical CT/SPECT systems acquire CT and SPECT data sequentially using different detectors in close proximity to minimise patient movement and interscan delay. We have developed a prototype simultaneous CT/SPECT imager, using a single CdZnTe detector, with the goal of improving image coregistration and decreasing scan time. A 16-pixel CdZnTe detector was operated in pulse-counting mode with 50 ns shaping time. Energy discrimination is used to separate the CT and SPECT data. Simultaneous SPECT and CT images were obtained for a phantom with the X-ray flux limited to reduce pulse pile-up in the radionuclide energy window. At 140 keV, the efficiency and energy resolution are 70% and 10%, respectively, and were constant for fluence rates up to 10{sup 3} cps per detector element for 140 keV gamma rays, but degrade rapidly at higher fluence rates. In pulse-counting mode, the maximum count rate of 10{sup 3} cps per element from the CdZnTe detector is sufficient for SPECT imaging, but is considerably lower than the fluence rates encountered in CT. The smallest lesion visually detectable in SPECT is 9 mm and the CT spatial resolution is smaller than 4.5 mm. Image registration is intrinsic because the data can be acquired simultaneously with a single detector with the same reconstruction geometry.

  10. Compartment Syndrome After Varicose Vein Surgery Evidenced by CT Images.

    Science.gov (United States)

    Wang, Sheng-Min; Kim, Maru

    2016-03-01

    A 21-year-old man developed compartment syndrome after a varicose vein surgery. Because of a lack of appropriate diagnostic apparatus, it was not possible to measure calf pressure. The only diagnostic tool available was computed tomography (CT). With the aid of CT, faster diagnosis of the compartment syndrome was possible, leading to appropriate management. By providing unique CT images of a patient before and after having compartment syndrome and after a fasciotomy, this study could add valuable references for diagnosis of compartment syndrome using CT. © The Author(s) 2014.

  11. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  12. Three dimensional analysis of coelacanth body structure by computer graphics and X-ray CT images

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Naoki (Jikei Univ., Tokyo (Japan). School of Medicine); Hamada, Takashi

    1990-06-01

    Three dimensional imaging processes were applied for the structural and functional analyses of the modern coelacanth (Latimeria chalumnae). Visualization of the obtained images is performed with computer graphics on the basis of serial images by an X-ray CT scanning method. Reconstruction of three dimensional images of the body structure of coelacanth using the volume rendering and surface rendering methods provides us various information about external and internal shapes of this exquisite fish. (author).

  13. Three-dimensional helical CT imaging of bone and joint diseases in the trunk and the hip joints. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Gong Hohghan [Jangxi Medical Coll. (China). First Affiliated Hospital; Hiraishi, Kumiko; Doi, Miwako; Matsui, Ritsuo; Simizu, Tadafumi; Sueyoshi, Kouzou; Narabayashi, Isamu

    1997-12-01

    To confirm the utility of CT scan images for orthopedic surgeons managing patients with complex disorders, we have produced and studied three-dimensional images from helical CT scans of 28 patients with various bone and joint disorders in the trunk and the hip joint. The CT scanner employed was a Toshiba X-force, and the 3D-CT images were constructed on an X-link50. The 3D images obtained could be observed from various projections. Congenital vertebral malformations, spondylosis, OPLL, osteonecrosis, fractures, and bone tumors were examined, and the 3D helical CT images brought useful information to bear on the spatial location and extent of the lesions. Therefore, 3D helical CT should become an indispensable tool for both preoperative examination and post-operative follow-up studies in orthopedic surgery. (author)

  14. PET/CT (and CT) instrumentation, image reconstruction and data transfer for radiotherapy planning

    DEFF Research Database (Denmark)

    Sattler, Bernhard; Lee, John A; Lonsdale, Markus;

    2010-01-01

    , especially when transferring data across the (network-) borders of different hospitals. Overall, the most important precondition for successful integration of functional imaging in RT treatment planning is the goal orientated as well as close and thorough communication between nuclear medicine......The positron emission tomography in combination with CT in hybrid, cross-modality imaging systems (PET/CT) gains more and more importance as a part of the treatment-planning procedure in radiotherapy. Positron emission tomography (PET), as a integral part of nuclear medicine imaging and non......-invasive imaging technique, offers the visualization and quantification of pre-selected tracer metabolism. In combination with the structural information from CT, this molecular imaging technique has great potential to support and improve the outcome of the treatment-planning procedure prior to radiotherapy...

  15. 'Ready-access' CT imaging for an orthopaedic trauma clinic.

    LENUS (Irish Health Repository)

    Cawley, D

    2011-03-01

    \\'Ready-Access\\' to CT imaging facilities in Orthopaedic Trauma Clinics is not a standard facility. This facility has been available at the regional trauma unit, in Merlin Park Hospital, Galway for the past four years. We reviewed the use of this facility over a 2-year period when 100 patients had CT scans as part of their trauma clinic assessment. The rate of CT scan per clinic was 0.6. The mean waiting time for a CT scan was 30 minutes. 20 (20%) new fractures were confirmed, 33 (33%) fractures were out-ruled, 25 (25%) fractures demonstrated additional information and 8 (8%) had additional fractures. 20 (20%) patients were discharged and 12 (12%) patients were admitted as a result of the CT scan. It adds little time and cost to CT scanning lists.

  16. Recurrent Convolutional Networks for Pulmonary Nodule Detection in CT Imaging

    OpenAIRE

    Ypsilantis, Petros-Pavlos; Montana, Giovanni

    2016-01-01

    Computed tomography (CT) generates a stack of cross-sectional images covering a region of the body. The visual assessment of these images for the identification of potential abnormalities is a challenging and time consuming task due to the large amount of information that needs to be processed. In this article we propose a deep artificial neural network architecture, ReCTnet, for the fully-automated detection of pulmonary nodules in CT scans. The architecture learns to distinguish nodules and...

  17. A new method for robust organ positioning in CT images

    NARCIS (Netherlands)

    Vik, T.; Bystrov, D.; Schadewaldt, N.; Schulz, H.; Peters, J.

    2012-01-01

    A robust initialization is the key to any successful segmentation process in medical images. For CT images, initialization ischallenging because the quality, appearance, content and field-of-view of the images are highly variable, and, furthermore, the user tolerance to errors in clinical applicatio

  18. A CT Image Segmentation Algorithm Based on Level Set Method

    Institute of Scientific and Technical Information of China (English)

    QU Jing-yi; SHI Hao-shan

    2006-01-01

    Level Set methods are robust and efficient numerical tools for resolving curve evolution in image segmentation. This paper proposes a new image segmentation algorithm based on Mumford-Shah module. The method is used to CT images and the experiment results demonstrate its efficiency and veracity.

  19. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  20. Quantifying trabecular bone material anisotropy and orientation using low resolution clinical CT images: A feasibility study.

    Science.gov (United States)

    Nazemi, S Majid; Cooper, David M L; Johnston, James D

    2016-09-01

    Accounting for spatial variation of trabecular material anisotropy and orientation can improve the accuracy of quantitative computed tomography-based finite element (FE) modeling of bone. The objective of this study was to investigate the feasibility of quantifying trabecular material anisotropy and orientation using clinical computed tomography (CT). Forty four cubic volumes of interest were obtained from micro-CT images of the human radius. Micro-FE modeling was performed on the samples to obtain orthotropic stiffness entries as well as trabecular orientation. Simulated computed tomography images (0.32, 0.37, and 0.5mm isotropic voxel sizes) were created by resampling micro-CT images with added image noise. The gray-level structure tensor was used to derive fabric eigenvalues and eigenvectors in simulated CT images. For 'best case' comparison purposes, Mean Intercept Length was used to define fabric from micro-CT images. Regression was used in combination with eigenvalues, imaged density and FE to inversely derive the constants used in Cowin and Zysset-Curnier fabric-elasticity equations, and for comparing image derived fabric-elasticity stiffness entries to those obtained using micro-FE. Image derived eigenvectors (which indicated trabecular orientation) were then compared to orientation derived using micro-FE. When using clinically available voxel sizes, gray-level structure tensor derived fabric combined with Cowin's equations was able to explain 94-97% of the variance in orthotropic stiffness entries while Zysset-Curnier equations explained 82-88% of the variance in stiffness. Image derived orientation deviated by 4.4-10.8° from micro-FE derived orientation. Our results indicate potential to account for spatial variation of trabecular material anisotropy and orientation in subject-specific finite element modeling of bone using clinically available CT.

  1. Image quality assessment for CT used on small animals

    Energy Technology Data Exchange (ETDEWEB)

    Cisneros, Isabela Paredes, E-mail: iparedesc@unal.edu.co; Agulles-Pedrós, Luis, E-mail: lagullesp@unal.edu.co [Universidad Nacional de Colombia, Departamento de Física, Grupo de Física Médica (Colombia)

    2016-07-07

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  2. Image quality assessment for CT used on small animals

    Science.gov (United States)

    Cisneros, Isabela Paredes; Agulles-Pedrós, Luis

    2016-07-01

    Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MatLab, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

  3. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  4. Qualitative and quantitative comparison of PET/CT and PET/MR imaging in clinical practice.

    Science.gov (United States)

    Al-Nabhani, Khalsa Z; Syed, Rizwan; Michopoulou, Sofia; Alkalbani, Jokha; Afaq, Asim; Panagiotidis, Emmanouil; O'Meara, Celia; Groves, Ashley; Ell, Peter; Bomanji, Jamshed

    2014-01-01

    The aim of this study was to prospectively compare whole-body PET/MR imaging and PET/CT, qualitatively and quantitatively, in oncologic patients and assess the confidence and degree of inter- and intraobserver agreement in anatomic lesion localization. Fifty patients referred for staging with known cancers underwent PET/CT with low-dose CT for attenuation correction immediately followed by PET/MR imaging with 2-point Dixon attenuation correction. PET/CT scans were obtained according to standard protocols (56 ± 20 min after injection of an average 367 MBq of (18)F-FDG, 150 MBq of (68)Ga-DOTATATE, or 333.8 MBq of (18)F-fluoro-ethyl-choline; 2.5 min/bed position). PET/MR was performed with 5 min/bed position. Three dual-accredited nuclear medicine physicians/radiologists identified the lesions and assigned each to an exact anatomic location. The image quality, alignment, and confidence in anatomic localization of lesions were scored on a scale of 1-3 for PET/CT and PET/MR imaging. Quantitative analysis was performed by comparing the standardized uptake values. Intraclass correlation coefficients and the Wilcoxon signed-rank test were used to assess intra- and interobserver agreement in image quality, alignment, and confidence in lesion localization for the 2 modalities. Two hundred twenty-seven tracer-avid lesions were identified in 50 patients. Of these, 225 were correctly identified on PET/CT and 227 on PET/MR imaging by all 3 observers. The confidence in anatomic localization improved by 5.1% when using PET/MR imaging, compared with PET/CT. The mean percentage interobserver agreement was 96% for PET/CT and 99% for PET/MR imaging, and intraobserver agreement in lesion localization across the 2 modalities was 93%. There was 10% (5/50 patients) improvement in local staging with PET/MR imaging, compared with PET/CT. In this first study, we show the effectiveness of whole-body PET/MR imaging in oncology. There is no statistically significant difference between PET

  5. The engagement of FDG PET/CT image quality and harmonized quantification: from competitive to complementary

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Ronald [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands)

    2016-01-15

    The use of {sup 18}F-FDG PET/CT as a quantitative imaging biomarker requires standardization and harmonization of imaging procedures and PET/CT system performance to obtain repeatable and reproducible quantitative data. However, a PET/CT system optimized to meet international quantitative standards is not necessarily optimized for use as a diagnostic tool (i.e. for lesion detectability). Several solutions have been proposed and validated, but until recently none of them had been implemented commercially. Vendor-provided solutions allowing the use of PET/CT both as a diagnostic tool and as a quantitative imaging biomarker are therefore greatly needed and would be highly appreciated. In this invited perspective one such solution is highlighted. (orig.)

  6. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  7. PET/CT Imaging in Mouse Models of Myocardial Ischemia

    Directory of Open Access Journals (Sweden)

    Sara Gargiulo

    2012-01-01

    Full Text Available Different species have been used to reproduce myocardial infarction models but in the last years mice became the animals of choice for the analysis of several diseases, due to their short life cycle and the possibility of genetic manipulation. Many techniques are currently used for cardiovascular imaging in mice, including X-ray computed tomography (CT, high-resolution ultrasound, magnetic resonance imaging, and nuclear medicine procedures. Cardiac positron emission tomography (PET allows to examine noninvasively, on a molecular level and with high sensitivity, regional changes in myocardial perfusion, metabolism, apoptosis, inflammation, and gene expression or to measure changes in anatomical and functional parameters in heart diseases. Currently hybrid PET/CT scanners for small laboratory animals are available, where CT adds high-resolution anatomical information. This paper reviews mouse models of myocardial infarction and discusses the applications of dedicated PET/CT systems technology, including animal preparation, anesthesia, radiotracers, and images postprocessing.

  8. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter [Heidelberg Univ. (Germany). Dept. of Diagnostic and Interventional Radiology; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U. [Heidelberg Univ. (Germany). Dept. of Obstetrics and Gynecology

    2011-11-15

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  9. Biomechanical deformable image registration of longitudinal lung CT images using vessel information

    Science.gov (United States)

    Cazoulat, Guillaume; Owen, Dawn; Matuszak, Martha M.; Balter, James M.; Brock, Kristy K.

    2016-07-01

    Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Six lung cancer patients previously treated with conventionally fractionated radiotherapy were retrospectively evaluated. Exhale CT scans were obtained at treatment planning and following three weeks of treatment. For each patient, the planning CT was registered to the follow-up CT using Morfeus, a biomechanical model-based deformable registration algorithm. To model the complex response of the lung, an extension to Morfeus has been developed: an initial deformation was estimated with Morfeus consisting of boundary conditions on the chest wall and incorporating a sliding interface with the lungs. It was hypothesized that the addition of boundary conditions based on vessel tree matching would provide a robust reduction of the residual registration error. To achieve this, the vessel trees were segmented on the two images by thresholding a vesselness image based on the Hessian matrix’s eigenvalues. For each point on the reference vessel tree centerline, the displacement vector was estimated by applying a variant of the Demons registration algorithm between the planning CT and the deformed follow-up CT. An expert independently identified corresponding landmarks well distributed in the lung to compute target registration errors (TRE). The TRE was: 5.8+/- 2.9 , 3.4+/- 2.3 and 1.6+/- 1.3 mm after rigid registration, Morfeus and Morfeus with boundary conditions on the vessel tree, respectively. In conclusion, the addition of boundary conditions on the vessels significantly improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these geometrical uncertainties will enable

  10. Modelling of classical ghost images obtained using scattered light

    Science.gov (United States)

    Crosby, S.; Castelletto, S.; Aruldoss, C.; Scholten, R. E.; Roberts, A.

    2007-08-01

    The images obtained in ghost imaging with pseudo-thermal light sources are highly dependent on the spatial coherence properties of the incident light. Pseudo-thermal light is often created by reducing the coherence length of a coherent source by passing it through a turbid mixture of scattering spheres. We describe a model for simulating ghost images obtained with such partially coherent light, using a wave-transport model to calculate the influence of the scattering on initially coherent light. The model is able to predict important properties of the pseudo-thermal source, such as the coherence length and the amplitude of the residual unscattered component of the light which influence the resolution and visibility of the final ghost image. We show that the residual ballistic component introduces an additional background in the reconstructed image, and the spatial resolution obtainable depends on the size of the scattering spheres.

  11. A minimum spanning forest based classification method for dedicated breast CT images

    Energy Technology Data Exchange (ETDEWEB)

    Pike, Robert [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Sechopoulos, Ioannis [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 and Winship Cancer Institute of Emory University, Atlanta, Georgia 30322 (United States); Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Science, Emory University, Atlanta, Georgia 30322 (United States); Winship Cancer Institute of Emory University, Atlanta, Georgia 30322 (United States)

    2015-11-15

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.

  12. Optimized Flat-Detector CT in Stroke Imaging: Ready for First-Line Use?

    Science.gov (United States)

    Eckert, Matthias; Gölitz, Philipp; Lücking, Hannes; Struffert, Tobias; Knossalla, Frauke; Doerfler, Arnd

    2017-01-01

    Using flat-detector CT (FD-CT) for stroke imaging has the advantage that both diagnostic imaging and endovascular therapy can be performed directly within the Angio Suite without any patient transfer and time delay. Thus, stroke management could be speeded up significantly, and patient outcome might be improved. But as precondition for using FD-CT as primary imaging modality, a reliable exclusion of intracranial hemorrhage (ICH) has to be possible. This study aimed to investigate whether optimized native FD-CT, using a newly implemented reconstruction algorithm, may reliably detect ICH in stroke patients. Additionally, the potential to identify ischemic changes was evaluated. Cranial FD-CT scans were obtained in 102 patients presenting with acute ischemic stroke (n = 32), ICH (n = 45) or transient ischemic attack (n = 25). All scans were reconstructed with a newly implemented half-scan cone-beam algorithm. Two experienced neuroradiologists, unaware of clinical findings, evaluated independently the FD-CTs screening for hemorrhage or ischemic signs. The findings were correlated to CT, and rater and inter-rater agreement was assessed. FD-CT demonstrated high sensitivity (95-100%) and specificity (100%) in detecting intracerebral and intraventricular hemorrhage (IVH). Overall, interobserver agreement (κ = 0.92) was almost perfect and rater agreement to CT highly significant (r = 0.81). One infratentorial ICH and 10 or 11 of 22 subarachnoid hemorrhages (SAHs) were missed of whom 7 were perimesencephalic. The sensitivity for detecting acute ischemic signs was poor in blinded readings (0 or 25%, respectively). Optimized FD-CT, using a newly implemented reconstruction algorithm, turned out as a reliable tool for detecting supratentorial ICH and IVH. However, detection of infratentorial ICH and perimesencephalic SAH is limited. The potential of FD-CT in detecting ischemic changes is poor in blinded readings. Thus, plain FD-CT seems insufficient as a standalone modality in

  13. PET/CT imaging and radioimmunotherapy of prostate cancer

    OpenAIRE

    Bouchelouche, Kirsten; Tagawa, Scott T.; Goldsmith, Stanley J.; Turkbey, Baris; Capala, Jacek; Choyke, Peter

    2011-01-01

    Prostate cancer is a common cancer in men and continues to be a major health problem. Imaging plays an important role in the clinical management of patients with prostate cancer. An important goal for prostate cancer imaging is more accurate disease characterization through the synthesis of anatomic, functional, and molecular imaging information. Positron emission tomography (PET)/computed tomography (CT) in oncology is emerging as an important imaging tool. The most common radiotracer for PE...

  14. Iodine contrast cone beam CT imaging of breast cancer

    Science.gov (United States)

    Partain, Larry; Prionas, Stavros; Seppi, Edward; Virshup, Gary; Roos, Gerhard; Sutherland, Robert; Boone, John

    2007-03-01

    An iodine contrast agent, in conjunction with an X-ray cone beam CT imaging system, was used to clearly image three, biopsy verified, cancer lesions in two patients. The lesions were approximately in the 10 mm to 6 mm diameter range. Additional regions were also enhanced with approximate dimensions down to 1 mm or less in diameter. A flat panel detector, with 194 μm pixels in 2 x 2 binning mode, was used to obtain 500 projection images at 30 fps with an 80 kVp X-ray system operating at 112 mAs, for an 8-9 mGy dose - equivalent to two view mammography for these women. The patients were positioned prone, while the gantry rotated in the horizontal plane around the uncompressed, pendant breasts. This gantry rotated 360 degrees during the patient's 16.6 sec breath hold. A volume of 100 cc of 320 mg/ml iodine-contrast was power injected at 4 cc/sec, via catheter into the arm vein of the patient. The resulting 512 x 512 x 300 cone beam CT data set of Feldkamp reconstructed ~(0.3 mm) 3 voxels were analyzed. An interval of voxel contrast values, characteristic of the regions with iodine contrast enhancement, were used with surface rendering to clearly identify up to a total of 13 highlighted volumes. This included the three largest lesions, that were previously biopsied and confirmed to be malignant. The other ten highlighted regions, of smaller diameters, are likely areas of increased contrast trapping unrelated to cancer angiogenesis. However the technique itself is capable of resolving lesions that small.

  15. US, CT and MR imaging characteristics of nephroblastomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Rohrschneider, W.K.; Weirich, A.; Darge, K.; Troeger, J. [Department of Pediatric Radiology, University of Heidelberg, Im Neuenheimer Feld 153, D-69 120 Heidelberg (Germany); Rieden, K. [Department of Radiology, University of Heidelberg, Heidelberg (Germany); Graf, N. [Department of Paediatric Oncology, Children`s Hospital, University of Homburg/Saar (Germany)

    1998-06-01

    Objectives. To describe the imaging features of nephroblastomatosis with US, CT and MR, to point out characteristics of differentiation between nephrogenic rests (NR) and Wilms` tumour (WT) and to determine the most appropriate imaging modality. Materials and methods. We reviewed the US, CT and MR images of 29 cases of histopathologically confirmed nephroblastomatosis sent to our department for reference evaluation (German nephroblastoma study). The series included 17 kidneys with NR, 6 kidneys with WT and 32 kidneys with both NR and WT. Results. NR presented as multinodular, peripheral, cortical lesions, the diffuse form of distribution being less common. Foci were homogeneous and of low echogenicity, density or signal intensity. The lesions were most clearly depicted with contrast-enhanced CT and T1-weighted (T1-W) MR images. Lesions smaller than 1 cm were rarely identified by US. The most reliable criterion to differentiate NR from WT was their homogeneity. Conclusions. Contrast-enhanced CT and T1-W MR images are of similar potential and superior to US in the diagnosis of nephroblastomatosis. Due to the significant radiation dose of serial CT, MR imaging should be the method of choice wherever it is available. The cost-effectiveness and availability of US makes it ideal for serial follow-up of known lesions. (orig.) With 8 figs., 1 tab., 23 refs.

  16. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  17. Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Mitsuru, E-mail: m2rbimn@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Kawai, Tatsuya; Ito, Masato; Ogawa, Masaki [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Hara, Masaki; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan)

    2012-11-15

    Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 {+-} 15 [SD] and -16 {+-} 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required.

  18. CT and MR imaging after middle ear surgery

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, Sabrina E-mail: sabrina.koesling@medizin.uni-halle.de; Bootz, F

    2001-11-01

    This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue.

  19. An image analysis approach for automatically re-orienteering CT images for dental implants.

    Science.gov (United States)

    Cucchiara, Rita; Lamma, Evelina; Sansoni, Tommaso

    2004-06-01

    In the last decade, computerized tomography (CT) has become the most frequently used imaging modality to obtain a correct pre-operative implant planning. In this work, we present an image analysis and computer vision approach able to identify, from the reconstructed 3D data set, the optimal cutting plane specific to each implant to be planned, in order to obtain the best view of the implant site and to have correct measures. If the patient requires more implants, different cutting planes are automatically identified, and the axial and cross-sectional images can be re-oriented accordingly to each of them. In the paper, we describe the defined algorithms in order to recognize 3D markers (each one aligned with a missed tooth for which an implant has to be planned) in the 3D reconstructed space, and the results in processing real exams, in terms of effectiveness and precision and reproducibility of the measure.

  20. CT imaging in acute ischemic stroke

    NARCIS (Netherlands)

    Borst, J.

    2016-01-01

    Time is of the essence when treating acute ischemic stroke, to limit the damage caused. One form of intra-arterial treatment (IAT) used in such cases is the mechanical removal of the blood clot using stent-retrievers. It is thought that patient selection for IAT requires improvement and that CT

  1. Automatic dental arch detection and panoramic image synthesis from CT images.

    Science.gov (United States)

    Sa-Ing, Vera; Wangkaoom, Kongyot; Thongvigitmanee, Saowapak S

    2013-01-01

    Due to accurate 3D information, computed tomography (CT), especially cone-beam CT or dental CT, has been widely used for diagnosis and treatment planning in dentistry. Axial images acquired from both medical and dental CT scanners can generate synthetic panoramic images similar to typical 2D panoramic radiographs. However, the conventional way to reconstruct the simulated panoramic images is to manually draw the dental arch on axial images. In this paper, we propose a new fast algorithm for automatic detection of the dental arch. Once the dental arch is computed, a series of synthetic panoramic images as well as a ray-sum panoramic image can be automatically generated. We have tested the proposed algorithm on 120 CT axial images and all of them can provide the decent estimate of the dental arch. The results show that our proposed algorithm can mostly detect the correct dental arch.

  2. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lauzier, Pascal Theriault; Tang Jie; Speidel, Michael A.; Chen Guanghong [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States); Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States)

    2012-07-15

    Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution

  3. A novel reconstruction tool (syngo DynaCT Head Clear) in the post-processing of DynaCT images to reduce artefacts and improve image quality.

    Science.gov (United States)

    Lescher, Stephanie; Reh, Christina; Hoelter, Maya Christina; Czeppan, Katja; Porto, Luciana; Blasel, Stella; Berkefeld, Joachim; Wagner, Marlies

    2016-01-19

    Latest generations of flat detector (FD) neuroangiography systems are able to obtain CT-like images of the brain parenchyma. Owing to the geometry of the C-arm system, cone beam artifacts are common and reduce image quality, especially at the periphery of the field of view. An advanced reconstruction algorithm (syngo DynaCT Head Clear) tackles these artifacts by using a modified interpolation-based 3D correction algorithm to improve image quality. Eleven volumetric datasets from FD-CT scans were reconstructed with the standard algorithm as well as with the advanced algorithm. In a two-step data analysis process, two reviewers compared dedicated regions of the skull and brain in both reconstruction modes using a 5-point scale (1, much better; 5, much worse; advanced vs standard algorithm). Both reviewers were blinded to the reconstruction mode. In a second step, two additional observers independently evaluated image quality of the 3D data (non-comparative evaluation) in dedicated regions also using a 5-point scale (1, not diagnostically evaluable; 5, good quality, perfectly usable for diagnosis) for both reconstruction algorithms. Both in the comparative evaluation of dedicated brain regions and in the independent analysis of the FD-CT datasets the observers rated a better image quality if the advanced algorithm was used. The improvement in image quality was statistically significant at both the supraganglionic (p=0.018) and the infratentorial (p=0.002) levels. The advanced reconstruction algorithm reduces typical artifacts in FD-CT images and improves image quality at the periphery of the field of view. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. CT guided diffuse optical tomography for breast cancer imaging

    Science.gov (United States)

    Baikejiang, Reheman; Zhang, Wei; Zhu, Dianwen; Li, Changqing

    2016-03-01

    Diffuse optical tomography (DOT) has attracted attentions in the last two decades due to its intrinsic sensitivity in imaging chromophores of tissues such as blood, water, and lipid. However, DOT has not been clinically accepted yet due to its low spatial resolution caused by strong optical scattering in tissues. Structural guidance provided by an anatomical imaging modality enhances the DOT imaging substantially. Here, we propose a computed tomography (CT) guided multispectral DOT imaging system for breast cancer detection. To validate its feasibility, we have built a prototype DOT imaging system which consists of a laser at wavelengths of 650 and an electron multiplying charge coupled device (EMCCD) camera. We have validated the CT guided DOT reconstruction algorithms with numerical simulations and phantom experiments, in which different imaging setup parameters, such as projection number of measurements, the width of measurement patch, have been investigated. Our results indicate that an EMCCD camera with air cooling is good enough for the transmission mode DOT imaging. We have also found that measurements at six projections are sufficient for DOT to reconstruct the optical targets with 4 times absorption contrast when the CT guidance is applied. Finally, we report our effort and progress on the integration of the multispectral DOT imaging system into a breast CT scanner.

  5. CT perfusion imaging in the management of posterior reversible encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Casey, S.O.; McKinney, A.; Teksam, M.; Liu, H.; Truwit, C.L. [Department of Radiology, University of Minnesota Medical School, 420 Delaware Street SE, Box 292, MN 55455, Minneapolis (United States)

    2004-04-01

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110-120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient. (orig.)

  6. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography.

    Science.gov (United States)

    Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias

    2015-01-01

    The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.

  7. Obtaining quantitative global tumoral state indicators based on whole-body PET/CT scans: a breast cancer case study.

    Science.gov (United States)

    Sampedro, Frederic; Domenech, Anna; Escalera, Sergio

    2014-04-01

    In this work we address the need for the computation of quantitative global tumoral state indicators from oncological whole-body PET/computed tomography scans. The combination of such indicators with other oncological information such as tumor markers or biopsy results would prove useful in oncological decision-making scenarios. From an ordering of 100 breast cancer patients on the basis of oncological state through visual analysis by a consensus of nuclear medicine specialists, a set of numerical indicators computed from image analysis of the PET/computed tomography scan is presented, which attempts to summarize a patient's oncological state in a quantitative manner taking into consideration the total tumor volume, aggressiveness, and spread. Results obtained by comparative analysis of the proposed indicators with respect to the experts' evaluation show up to 87% Pearson's correlation coefficient when providing expert-guided PET metabolic tumor volume segmentation and 64% correlation when using completely automatic image analysis techniques. Global quantitative tumor information obtained by whole-body PET/CT image analysis can prove useful in clinical nuclear medicine settings and oncological decision-making scenarios. The completely automatic computation of such indicators would improve its impact as time efficiency and specialist independence would be achieved.

  8. CT imaging of mass-like renal lesions in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Y. [Children' s Hospital Boston, Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2007-09-15

    Mass-like renal lesions in children occur in a diverse spectrum of conditions including benign and malignant neoplasm, infection, infarction, lymphatic malformation, and traumatic injury. Although mass-like renal lesions can sometimes be suspected on plain radiographs and evaluated with US in children, subsequent CT is usually performed for the confirmation of diagnosis and further characterization. The purpose of this pictorial essay was to review the CT imaging findings of both common and uncommon mass-like renal lesions in pediatric patients. Understanding the characteristic CT appearance of mass-like renal lesions in children enables an accurate diagnosis and optimizes patient management. (orig.)

  9. Image quality in CT: From physical measurements to model observers.

    OpenAIRE

    2015-01-01

    Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners o...

  10. Phase-contrast CT: fundamental theorem and fast image reconstruction algorithms

    Science.gov (United States)

    Bronnikov, Andrei V.

    2006-08-01

    Phase-contrast x-ray computed tomography (CT) is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources or by using a microfocus x-ray tube. Promising experimental results have recently been obtained in material science and biological applications. At the same time, the lack of a mathematical theory comparable to that of conventional absorption-based CT limits the progress in this field. We suggest such a theory and prove a fundamental theorem that plays the same role for phase-contrast CT as the Fourier slice theorem does for absorption-based CT. The fundamental theorem allows us to derive fast image reconstruction algorithms in the form of filtered backprojection (FBP).

  11. CT and MR image fusion scheme in nonsubsampled contourlet transform domain.

    Science.gov (United States)

    Ganasala, Padma; Kumar, Vinod

    2014-06-01

    Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing an effective CT and MR image fusion method. In the proposed method, first source images are decomposed by using nonsubsampled contourlet transform (NSCT) which is a shift-invariant, multiresolution and multidirection image decomposition transform. Maximum entropy of square of the coefficients with in a local window is used for low-frequency sub-band coefficient selection. Maximum weighted sum-modified Laplacian is used for high-frequency sub-bands coefficient selection. Finally fused image is obtained through inverse NSCT. CT and MR images of different cases have been used to test the proposed method and results are compared with those of the other conventional image fusion methods. Both visual analysis and quantitative evaluation of experimental results shows the superiority of proposed method as compared to other methods.

  12. Edge-oriented dual-dictionary guided enrichment (EDGE) for MRI-CT image reconstruction.

    Science.gov (United States)

    Li, Liang; Wang, Bigong; Wang, Ge

    2016-01-01

    In this paper, we formulate the joint/simultaneous X-ray CT and MRI image reconstruction. In particular, a novel algorithm is proposed for MRI image reconstruction from highly under-sampled MRI data and CT images. It consists of two steps. First, a training dataset is generated from a series of well-registered MRI and CT images on the same patients. Then, an initial MRI image of a patient can be reconstructed via edge-oriented dual-dictionary guided enrichment (EDGE) based on the training dataset and a CT image of the patient. Second, an MRI image is reconstructed using the dictionary learning (DL) algorithm from highly under-sampled k-space data and the initial MRI image. Our algorithm can establish a one-to-one correspondence between the two imaging modalities, and obtain a good initial MRI estimation. Both noise-free and noisy simulation studies were performed to evaluate and validate the proposed algorithm. The results with different under-sampling factors show that the proposed algorithm performed significantly better than those reconstructed using the DL algorithm from MRI data alone.

  13. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  14. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities

    Science.gov (United States)

    Weidlich, Georg A.

    2016-01-01

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities—fan beam and cone beam—was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient. PMID:27752404

  15. Surgical stent for dental implant using cone beam CT images

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, School of Dentistry, Kung Hee University, Seoul (Korea, Republic of)

    2010-12-15

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  16. Efficient iterative image reconstruction algorithm for dedicated breast CT

    Science.gov (United States)

    Antropova, Natalia; Sanchez, Adrian; Reiser, Ingrid S.; Sidky, Emil Y.; Boone, John; Pan, Xiaochuan

    2016-03-01

    Dedicated breast computed tomography (bCT) is currently being studied as a potential screening method for breast cancer. The X-ray exposure is set low to achieve an average glandular dose comparable to that of mammography, yielding projection data that contains high levels of noise. Iterative image reconstruction (IIR) algorithms may be well-suited for the system since they potentially reduce the effects of noise in the reconstructed images. However, IIR outcomes can be difficult to control since the algorithm parameters do not directly correspond to the image properties. Also, IIR algorithms are computationally demanding and have optimal parameter settings that depend on the size and shape of the breast and positioning of the patient. In this work, we design an efficient IIR algorithm with meaningful parameter specifications and that can be used on a large, diverse sample of bCT cases. The flexibility and efficiency of this method comes from having the final image produced by a linear combination of two separately reconstructed images - one containing gray level information and the other with enhanced high frequency components. Both of the images result from few iterations of separate IIR algorithms. The proposed algorithm depends on two parameters both of which have a well-defined impact on image quality. The algorithm is applied to numerous bCT cases from a dedicated bCT prototype system developed at University of California, Davis.

  17. Automatic lung tumor segmentation on PET/CT images using fuzzy Markov random field model.

    Science.gov (United States)

    Guo, Yu; Feng, Yuanming; Sun, Jian; Zhang, Ning; Lin, Wang; Sa, Yu; Wang, Ping

    2014-01-01

    The combination of positron emission tomography (PET) and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF) model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC) patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice's similarity coefficient (DSC) was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  18. Automatic Lung Tumor Segmentation on PET/CT Images Using Fuzzy Markov Random Field Model

    Directory of Open Access Journals (Sweden)

    Yu Guo

    2014-01-01

    Full Text Available The combination of positron emission tomography (PET and CT images provides complementary functional and anatomical information of human tissues and it has been used for better tumor volume definition of lung cancer. This paper proposed a robust method for automatic lung tumor segmentation on PET/CT images. The new method is based on fuzzy Markov random field (MRF model. The combination of PET and CT image information is achieved by using a proper joint posterior probability distribution of observed features in the fuzzy MRF model which performs better than the commonly used Gaussian joint distribution. In this study, the PET and CT simulation images of 7 non-small cell lung cancer (NSCLC patients were used to evaluate the proposed method. Tumor segmentations with the proposed method and manual method by an experienced radiation oncologist on the fused images were performed, respectively. Segmentation results obtained with the two methods were similar and Dice’s similarity coefficient (DSC was 0.85 ± 0.013. It has been shown that effective and automatic segmentations can be achieved with this method for lung tumors which locate near other organs with similar intensities in PET and CT images, such as when the tumors extend into chest wall or mediastinum.

  19. Semi-automatic delineation using weighted CT-MRI registered images for radiotherapy of nasopharyngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fitton, I. [European Georges Pompidou Hospital, Department of Radiology, 20 rue Leblanc, 75015, Paris (France); Cornelissen, S. A. P. [Image Sciences Institute, UMC, Department of Radiology, P.O. Box 85500, 3508 GA Utrecht (Netherlands); Duppen, J. C.; Rasch, C. R. N.; Herk, M. van [The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Radiotherapy, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Steenbakkers, R. J. H. M. [University Medical Center Groningen, Department of Radiation Oncology, Hanzeplein 1, 9713 GZ Groningen (Netherlands); Peeters, S. T. H. [UZ Gasthuisberg, Herestraat 49, 3000 Leuven, Belgique (Belgium); Hoebers, F. J. P. [Maastricht University Medical Center, Department of Radiation Oncology (MAASTRO clinic), GROW School for Oncology and Development Biology Maastricht, 6229 ET Maastricht (Netherlands); Kaanders, J. H. A. M. [UMC St-Radboud, Department of Radiotherapy, Geert Grooteplein 32, 6525 GA Nijmegen (Netherlands); Nowak, P. J. C. M. [ERASMUS University Medical Center, Department of Radiation Oncology,Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2011-08-15

    Purpose: To develop a delineation tool that refines physician-drawn contours of the gross tumor volume (GTV) in nasopharynx cancer, using combined pixel value information from x-ray computed tomography (CT) and magnetic resonance imaging (MRI) during delineation. Methods: Operator-guided delineation assisted by a so-called ''snake'' algorithm was applied on weighted CT-MRI registered images. The physician delineates a rough tumor contour that is continuously adjusted by the snake algorithm using the underlying image characteristics. The algorithm was evaluated on five nasopharyngeal cancer patients. Different linear weightings CT and MRI were tested as input for the snake algorithm and compared according to contrast and tumor to noise ratio (TNR). The semi-automatic delineation was compared with manual contouring by seven experienced radiation oncologists. Results: A good compromise for TNR and contrast was obtained by weighing CT twice as strong as MRI. The new algorithm did not notably reduce interobserver variability, it did however, reduce the average delineation time by 6 min per case. Conclusions: The authors developed a user-driven tool for delineation and correction based a snake algorithm and registered weighted CT image and MRI. The algorithm adds morphological information from CT during the delineation on MRI and accelerates the delineation task.

  20. PET/CT (and CT) instrumentation, image reconstruction and data transfer for radiotherapy planning.

    Science.gov (United States)

    Sattler, Bernhard; Lee, John A; Lonsdale, Markus; Coche, Emmanuel

    2010-09-01

    The positron emission tomography in combination with CT in hybrid, cross-modality imaging systems (PET/CT) gains more and more importance as a part of the treatment-planning procedure in radiotherapy. Positron emission tomography (PET), as a integral part of nuclear medicine imaging and non-invasive imaging technique, offers the visualization and quantification of pre-selected tracer metabolism. In combination with the structural information from CT, this molecular imaging technique has great potential to support and improve the outcome of the treatment-planning procedure prior to radiotherapy. By the choice of the PET-Tracer, a variety of different metabolic processes can be visualized. First and foremost, this is the glucose metabolism of a tissue as well as for instance hypoxia or cell proliferation. This paper comprises the system characteristics of hybrid PET/CT systems. Acquisition and processing protocols are described in general and modifications to cope with the special needs in radiooncology. This starts with the different position of the patient on a special table top, continues with the use of the same fixation material as used for positioning of the patient in radiooncology while simulation and irradiation and leads to special processing protocols that include the delineation of the volumes that are subject to treatment planning and irradiation (PTV, GTV, CTV, etc.). General CT acquisition and processing parameters as well as the use of contrast enhancement of the CT are described. The possible risks and pitfalls the investigator could face during the hybrid-imaging procedure are explained and listed. The interdisciplinary use of different imaging modalities implies a increase of the volume of data created. These data need to be stored and communicated fast, safe and correct. Therefore, the DICOM-Standard provides objects and classes for this purpose (DICOM RT). Furthermore, the standard DICOM objects and classes for nuclear medicine (NM, PT) and

  1. Molecular imaging for prostate cancer: Performance analysis of (68)Ga-PSMA PET/CT versus choline PET/CT.

    Science.gov (United States)

    Michaud, L; Touijer, K A

    2017-06-01

    There is a need for a precise and reliable imaging to improve the management of prostate cancer. In recent years the PET/CT with choline has changed the handling of prostate cancer in Europe, and it is commonly used for initial stratification or for the diagnosis of a biochemical recurrence, although it does not lack limitations. Other markers are being tested, including the ligand of prostate-specific membrane antigen (PSMA), that seems to offer encouraging prospects. The goal of this piece of work was to critically review the role of choline and PSMA PET/CT in prostate cancer. A systematic literature review of databases PUBMED/MEDLINE and EMBASE was conducted searching for articles fully published in English on the PET marker in prostate cancer and its clinical application. It seems as 68Ga-PSMA PET/CT is better than PET/CT in prostate cancer to detect primary prostate lesions, initial metastases in the lymph nodes and recurrence. However, further research is required to obtain high-level tests. Also, other PET markers are studied. Moreover, the emergence of a new PET/MR camera could change the performance of PET imaging. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Prior CT imaging history for patients who undergo PAN CT for acute traumatic injury

    Directory of Open Access Journals (Sweden)

    Jeremy Kenter

    2015-06-01

    Full Text Available Objective. A single PAN scan may provide more radiation to a patient than is felt to be safe within a one-year period. Our objective was to determine how many patients admitted to the trauma service following a PAN scan had prior CT imaging within our six-hospital system.Methods. We performed a secondary analysis of a prospectively collected trauma registry. The study was based at a level-two trauma center and five affiliated hospitals, which comprise 70.6% of all Emergency Department visits within a twelve county region of southern Texas. Electronic medical records were reviewed dating from the point of trauma evaluation back to December 5, 2005 to determine evidence of prior CT imaging.Results. There were 867 patients were admitted to the trauma service between January 1, 2012 and December 31, 2012. 460 (53% received a PAN scan and were included in the study group. The mean age of the study group was 37.7 ± 1.54 years old, 24.8% were female, and the mean ISS score was 13.4 ± 1.07. The most common mechanism of injury was motor vehicle collision (47%. 65 (14%; 95% CI [11–18]% of the patients had at least one prior CT. The most common prior studies performed were: CT head (29%; 19–42%, CT Face (29%; 19–42% and CT Abdomen and Pelvis (18%; 11–30%.Conclusion. Within our trauma registry, 14% of patients had prior CT imaging within our hospital system before their traumatic event and PAN scan.

  3. CT vaginography: a new CT technique for imaging of upper and middle vaginal fistulas.

    Science.gov (United States)

    Botsikas, Diomidis; Pluchino, Nicola; Kalovidouri, Anastasia; Platon, Alexandra; Montet, Xavier; Dallenbach, Patrick; Poletti, Pierre-Alexandre

    2017-05-01

    Different types of vaginal fistulas is a relatively uncommon condition in the Western world but very frequent in developing countries. In the past, conventional vaginography was the radiological examination of choice for exploring this condition. CT and MRI are now both used for this purpose. Our objective was to test the feasibility and to explore the potential role of a new CT imaging technique implementing vaginal introitus obstruction and opacification of the vagina with iodine contrast agent, to show patency of a fistula. We describe the technical protocol of CT-vaginography as performed in Geneva University Hospitals, including vaginal catheterization with a Foley catheter and obstruction of the introitus by inflating the balloon of the catheter. We also report three cases of patients with suspected vaginal fistula who underwent CT-vaginography. The examinations were technically successful. In one patient, it revealed the presence of fistulous pathways from the vaginal fornix along the bilateral infected surgical prostheses. In a second patient, it showed a fistula between the vagina and the necrotic cavity of a recurrent cervical cancer. In a third patient, it proved the absence of a suspected vaginal fistula. CT-vaginography is a technically feasible CT protocol that provides anatomical and functional information on clinically suspected vaginal fistulas. Advances in knowledge: After the abandon of conventional vaginography in the era of transaxial imaging, the current modalities of imaging vaginal fistulas provide excellent anatomical detail but less functional information concerning the permeability of a vaginal fistulous pathway. We propose the use of CT-vaginography, a technical protocol that we describe in detail.

  4. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  5. CT x-ray tube voltage optimisation and image reconstruction evaluation using visual grading analysis

    Science.gov (United States)

    Zheng, Xiaoming; Kim, Ted M.; Davidson, Rob; Lee, Seongju; Shin, Cheongil; Yang, Sook

    2014-03-01

    The purposes of this work were to find an optimal x-ray voltage for CT imaging and to determine the diagnostic effectiveness of image reconstruction techniques by using the visual grading analysis (VGA). Images of the PH-5 CT abdomen phantom (Kagaku Co, Kyoto) were acquired by the Toshiba Aquillion One 320 slices CT system with various exposures (from 10 to 580 mAs) under different tube peak voltages (80, 100 and 120 kVp). The images were reconstructed by employing the FBP and the AIDR 3D iterative reconstructions with Mild, Standard and Strong FBP blending. Image quality was assessed by measuring noise, contrast to noise ratio and human observer's VGA scores. The CT dose index CTDIv was obtained from the values displayed on the images. The best fit for the curves of the image quality VGA vs dose CTDIv is a logistic function from the SPSS estimation. A threshold dose Dt is defined as the CTDIv at the just acceptable for diagnostic image quality and a figure of merit (FOM) is defined as the slope of the standardised logistic function. The Dt and FOM were found to be 5.4, 8.1 and 9.1 mGy and 0.47, 0.51 and 0.38 under the tube voltages of 80, 100 and 120 kVp, respectively, from images reconstructed by the FBP technique. The Dt and FOM values were lower from the images reconstructed by the AIDR 3D in comparison with the FBP technique. The optimal xray peak voltage for the imaging of the PH-5 abdomen phantom by the Aquillion One CT system was found to be at 100 kVp. The images reconstructed by the FBP are more diagnostically effective than that by the AIDR 3D but with a higher dose Dt to the patients.

  6. Automated delineation of stroke lesions using brain CT images

    Directory of Open Access Journals (Sweden)

    Céline R. Gillebert

    2014-01-01

    Full Text Available Computed tomographic (CT images are widely used for the identification of abnormal brain tissue following infarct and hemorrhage in stroke. Manual lesion delineation is currently the standard approach, but is both time-consuming and operator-dependent. To address these issues, we present a method that can automatically delineate infarct and hemorrhage in stroke CT images. The key elements of this method are the accurate normalization of CT images from stroke patients into template space and the subsequent voxelwise comparison with a group of control CT images for defining areas with hypo- or hyper-intense signals. Our validation, using simulated and actual lesions, shows that our approach is effective in reconstructing lesions resulting from both infarct and hemorrhage and yields lesion maps spatially consistent with those produced manually by expert operators. A limitation is that, relative to manual delineation, there is reduced sensitivity of the automated method in regions close to the ventricles and the brain contours. However, the automated method presents a number of benefits in terms of offering significant time savings and the elimination of the inter-operator differences inherent to manual tracing approaches. These factors are relevant for the creation of large-scale lesion databases for neuropsychological research. The automated delineation of stroke lesions from CT scans may also enable longitudinal studies to quantify changes in damaged tissue in an objective and reproducible manner.

  7. Automated segmentation of acetabulum and femoral head from 3-D CT images.

    Science.gov (United States)

    Zoroofi, Reza A; Sato, Yoshinobu; Sasama, Toshihiko; Nishii, Takashi; Sugano, Nobuhiko; Yonenobu, Kazuo; Yoshikawa, Hideki; Ochi, Takahiro; Tamura, Shinichi

    2003-12-01

    This paper describes several new methods and software for automatic segmentation of the pelvis and the femur, based on clinically obtained multislice computed tomography (CT) data. The hip joint is composed of the acetabulum, cavity of the pelvic bone, and the femoral head. In vivo CT data sets of 60 actual patients were used in the study. The 120 (60 x 2) hip joints in the data sets were divided into four groups according to several key features for segmentation. Conventional techniques for classification of bony tissues were first employed to distinguish the pelvis and the femur from other CT tissue images in the hip joint. Automatic techniques were developed to extract the boundary between the acetabulum and the femoral head. An automatic method was built up to manage the segmentation task according to image intensity of bone tissues, size, center, shape of the femoral heads, and other characters. The processing scheme consisted of the following five steps: 1) preprocessing, including resampling 3-D CT data by a modified Sinc interpolation to create isotropic volume and to avoid Gibbs ringing, and smoothing the resulting images by a 3-D Gaussian filter; 2) detecting bone tissues from CT images by conventional techniques including histogram-based thresholding and binary morphological operations; 3) estimating initial boundary of the femoral head and the joint space between the acetabulum and the femoral head by a new approach utilizing the constraints of the greater trochanter and the shapes of the femoral head; 4) enhancing the joint space by a Hessian filter; and 5) refining the rough boundary obtained in step 3) by a moving disk technique and the filtered images obtained in step 4). The above method was implemented in a Microsoft Windows software package and the resulting software is freely available on the Internet. The feasibility of this method was tested on the data sets of 60 clinical cases (5000 CT images).

  8. Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner

    Science.gov (United States)

    Du, Louise Y.; Lee, Ting-Yim; Holdsworth, David W.

    2006-03-01

    Small animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. Current micro-CT systems are capable of achieving spatial resolution on the order of 10 μm, giving highly detailed anatomical information. However, the speed of data acquisition of these systems is relatively slow, when compared with clinical CT systems. Dynamic CT perfusion imaging has proven to be a powerful tool clinically in detecting and diagnosing cancer, stroke, pulmonary and ischemic heart diseases. In order to perform this technique in mice and rats, quantitative CT images must be acquired at a rate of at least 1 Hz. Recently, a research pre-clinical CT scanner (eXplore Ultra, GE Healthcare) has been designed specifically for dynamic perfusion imaging in small animals. Using an amorphous silicon flat-panel detector and a clinical slip-ring gantry, this system is capable of acquiring volumetric image data at a rate of 1 Hz, with in-plane resolution of 150 μm, while covering the entire thoracic region of a mouse or whole organs of a rat. The purpose of this study was to evaluate the principal imaging performance of the micro-CT system, in terms of spatial resolution, image uniformity, linearity, dose and voxel noise for the feasibility of imaging mice and rats. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.7 line pairs per mm and noise of 42 HU, using an acquisition interval of 8 seconds at an entrance dose of 6.4 cGy.

  9. Nasal polyps with metaplastic ossification: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yi Kyung; Kim, Hyung-Jin; Kim, Eunhee; Kim, Sung Tae [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jinna [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Chung, Seung-Kyu [Sungkyunkwan University School of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Seoul (Korea, Republic of); Ko, Young-Hyeh [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2010-12-15

    Metaplastic ossification is a rare event in nasal polyps. The purpose of this study was to review the computed tomography (CT) and magnetic resonance (MR) imaging findings of nasal polyps with metaplastic ossification. CT (n = 5) and MR (n = 3) images of five patients (four men and one woman; mean age, 59 years) with surgically proven nasal polyp with metaplastic ossification were retrospectively reviewed. The location and morphologic characteristics of metaplastic ossification were documented as well. All lesions were seen as lobulated (n = 3), ovoid (n = 1), or dumbbell-shaped (n = 1) benign-looking masses with a mean size of 3.7 cm (range, 2.4-6.5 cm), located unilaterally in the posterior nasal cavity and nasopharynx (n = 2), posterior nasoethmoidal tract (n = 2), and maxillary sinus and nasal cavity (n = 1). Compared with the brain stem, the soft tissue components of all lesions demonstrated isoattenuation on precontrast CT scans, slight hypointensity on T1-weighted MR images, and hyperintensity on T2-weighted MR images. On contrast-enhanced MR images, heterogeneous enhancement with marked peripheral enhancement was seen in two and homogeneous moderate enhancement in one. All lesions contained centrally located radiodense materials on CT scans, the shape of which was multiple clustered in three, single nodular in one, and single large lobulated in one. Although rare, metaplastic ossification can occur within nasal polyps. The possibility of its diagnosis may be raised when one sees a benign-looking sinonasal mass with centrally located radiodense materials on CT scans. MR imaging may be useful when mycetoma or inverted papilloma cannot be ruled out on CT scans. (orig.)

  10. CT/FMT dual-model imaging of breast cancer based on peptide-lipid nanoparticles

    Science.gov (United States)

    Xu, Guoqiang; Lin, Qiaoya; Lian, Lichao; Qian, Yuan; Lu, Lisen; Zhang, Zhihong

    2016-03-01

    Breast cancer is one of the most harmful cancers in human. Its early diagnosis is expected to improve the patients' survival rate. X-ray computed tomography (CT) has been widely used in tumor detection for obtaining three-dimentional information. Fluorescence Molecular Tomography (FMT) imaging combined with near-infrared fluorescent dyes provides a powerful tool for the acquisition of molecular biodistribution information in deep tissues. Thus, the combination of CT and FMT imaging modalities allows us to better differentiate diseased tissues from normal tissues. Here we developed a tumor-targeting nanoparticle for dual-modality imaging based on a biocompatible HDL-mimicking peptide-phospholipid scaffold (HPPS) nanocarrier. By incorporation of CT contrast agents (iodinated oil) and far-infrared fluorescent dyes (DiR-BOA) into the hydrophobic core of HPPS, we obtained the FMT and CT signals simultaneously. Increased accumulation of the nanoparticles in the tumor lesions was achieved through the effect of the tumor-targeting peptide on the surface of nanoparticle. It resulted in excellent contrast between lesions and normal tissues. Together, the abilities to sensitively separate the lesions from adjacent normal tissues with the aid of a FMT/CT dual-model imaging approach make the targeting nanoparticles a useful tool for the diagnostics of breast cancer.

  11. An Improved Total Variation Minimization Method Using Prior Images and Split-Bregman Method in CT Reconstruction

    Science.gov (United States)

    2016-01-01

    Compressive Sensing (CS) theory has great potential for reconstructing Computed Tomography (CT) images from sparse-views projection data and Total Variation- (TV-) based CT reconstruction method is very popular. However, it does not directly incorporate prior images into the reconstruction. To improve the quality of reconstructed images, this paper proposed an improved TV minimization method using prior images and Split-Bregman method in CT reconstruction, which uses prior images to obtain valuable previous information and promote the subsequent imaging process. The images obtained asynchronously were registered via Locally Linear Embedding (LLE). To validate the method, two studies were performed. Numerical simulation using an abdomen phantom has been used to demonstrate that the proposed method enables accurate reconstruction of image objects under sparse projection data. A real dataset was used to further validate the method. PMID:27689076

  12. The utilization of dual source CT in imaging of polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Nicolaou, S. [University of British Columbia, Vancouver General Hospital, Department of Radiology, 899 West 12th Avenue, Vancouver, British Columbia, V5Z1M9 (Canada)], E-mail: savvas.nicolaou@vch.ca; Eftekhari, A.; Sedlic, T.; Hou, D.J.; Mudri, M.J.; Aldrich, John; Louis, L. [University of British Columbia, Vancouver General Hospital, Department of Radiology, 899 West 12th Avenue, Vancouver, British Columbia, V5Z1M9 (Canada)

    2008-12-15

    Despite the growing role of imaging, trauma remains the leading cause of death in people below the age of 45 years in the western industrialized countries. Trauma has been touted as the largest epidemic in the 20th century. The advent of MDCT has been the greatest advance in trauma care in the last 25 years. However, there are still challenges in CT imaging of the polytrauma individual including time restraints, diagnostic errors, radiation dose effects and bridging the gap between anatomy and physiology. This article will analyze these challenges and provide possible solutions offered by the unique design of the dual source CT scanner.

  13. PET/CT imaging in lung cancer: indications and findings

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-06-01

    Full Text Available The use of PET/CT imaging in the work-up and management of patients with lung cancer has greatly increased in recent decades. The ability to combine functional and anatomical information has equipped PET/CT to look into various aspects of lung cancer, allowing more precise disease staging and providing useful data during the characterization of indeterminate pulmonary nodules. In addition, the accuracy of PET/CT has been shown to be greater than is that of conventional modalities in some scenarios, making PET/CT a valuable noninvasive method for the investigation of lung cancer. However, the interpretation of PET/CT findings presents numerous pitfalls and potential confounders. Therefore, it is imperative for pulmonologists and radiologists to familiarize themselves with the most relevant indications for and limitations of PET/CT, seeking to protect their patients from unnecessary radiation exposure and inappropriate treatment. This review article aimed to summarize the basic principles, indications, cancer staging considerations, and future applications related to the use of PET/CT in lung cancer.

  14. CT and MR imaging of desmoplastic fibroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Shuto, Rieko; Kiyosue, Hiro; Hori, Yuko; Miyake, Hidetoshi; Mori, Hiromu [Department of Radiology, Oita Medical University, Hasama-machi, Oita 879-5593 (Japan); Kawano, Katsunori [1. Department of Surgery, Oita Medical University, Hasama-machi, Oita 879-5593 (Japan)

    2002-10-01

    Desmoplastic fibroblastoma (collagenous fibroma) developing as a slowly enlarging lower abdominal mass is described. The lesion had inhomogeneous low signal intensity (SI) on T1-weighted images, and mixed SI as low SI within high SI on T2-weighted images. On post-contrast T1-weighted images, the mass showed inhomogeneous enhancement. Histologically, the areas showing low SI on both post-contrast T1- and T2-weighted images consisted of dense collagenous components and reduced cellularity compared with the areas showing high SI on them. (orig.)

  15. PET/CT Imaging and Radioimmunotherapy of Prostate Cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Tagawa, Scott T; Goldsmith, Stanley J;

    2011-01-01

    Prostate cancer is a common cancer in men and continues to be a major health problem. Imaging plays an important role in the clinical management of patients with prostate cancer. An important goal for prostate cancer imaging is more accurate disease characterization through the synthesis...... disease (ideal for antigen access and antibody delivery). Furthermore, prostate cancer is also radiation sensitive. Prostate-specific membrane antigen is expressed by virtually all prostate cancers, and represents an attractive target for RIT. Antiprostate-specific membrane antigen RIT demonstrates...... of anatomic, functional, and molecular imaging information. Positron emission tomography (PET)/computed tomography (CT) in oncology is emerging as an important imaging tool. The most common radiotracer for PET/CT in oncology, (18)F-fluorodeoxyglucose (FDG), is not very useful in the imaging of prostate cancer...

  16. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, R. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology; Johansen, J.G. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology

    1995-09-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG).

  17. 3D-CT imaging processing for qualitative and quantitative analysis of maxillofacial cysts and tumors

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti, Marcelo de Gusmao Paraiso [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Radiologia; Antunes, Jose Leopoldo Ferreira [Sao Paulo Univ., SP (Brazil). Faculdade de Odotologia. Dept. de Odontologia Social

    2002-09-01

    The objective of this study was to evaluate spiral-computed tomography (3D-CT) images of 20 patients presenting with cysts and tumors in the maxillofacial complex, in order to compare the surface and volume techniques of image rendering. The qualitative and quantitative appraisal indicated that the volume technique allowed a more precise and accurate observation than the surface method. On the average, the measurements obtained by means of the 3D volume-rendering technique were 6.28% higher than those obtained by means of the surface method. The sensitivity of the 3D surface technique was lower than that of the 3D volume technique for all conditions stipulated in the diagnosis and evaluation of lesions. We concluded that the 3D-CT volume rendering technique was more reproducible and sensitive than the 3D-CT surface method, in the diagnosis, treatment planning and evaluation of maxillofacial lesions, especially those with intra-osseous involvement. (author)

  18. Automatic anatomy recognition on CT images with pathology

    Science.gov (United States)

    Huang, Lidong; Udupa, Jayaram K.; Tong, Yubing; Odhner, Dewey; Torigian, Drew A.

    2016-03-01

    Body-wide anatomy recognition on CT images with pathology becomes crucial for quantifying body-wide disease burden. This, however, is a challenging problem because various diseases result in various abnormalities of objects such as shape and intensity patterns. We previously developed an automatic anatomy recognition (AAR) system [1] whose applicability was demonstrated on near normal diagnostic CT images in different body regions on 35 organs. The aim of this paper is to investigate strategies for adapting the previous AAR system to diagnostic CT images of patients with various pathologies as a first step toward automated body-wide disease quantification. The AAR approach consists of three main steps - model building, object recognition, and object delineation. In this paper, within the broader AAR framework, we describe a new strategy for object recognition to handle abnormal images. In the model building stage an optimal threshold interval is learned from near-normal training images for each object. This threshold is optimally tuned to the pathological manifestation of the object in the test image. Recognition is performed following a hierarchical representation of the objects. Experimental results for the abdominal body region based on 50 near-normal images used for model building and 20 abnormal images used for object recognition show that object localization accuracy within 2 voxels for liver and spleen and 3 voxels for kidney can be achieved with the new strategy.

  19. Assessment of CT image quality using a Bayesian approach

    Science.gov (United States)

    Reginatto, M.; Anton, M.; Elster, C.

    2017-08-01

    One of the most promising approaches for evaluating CT image quality is task-specific quality assessment. This involves a simplified version of a clinical task, e.g. deciding whether an image belongs to the class of images that contain the signature of a lesion or not. Task-specific quality assessment can be done by model observers, which are mathematical procedures that carry out the classification task. The most widely used figure of merit for CT image quality is the area under the ROC curve (AUC), a quantity which characterizes the performance of a given model observer. In order to estimate AUC from a finite sample of images, different approaches from classical statistics have been suggested. The goal of this paper is to introduce task-specific quality assessment of CT images to metrology and to propose a novel Bayesian estimation of AUC for the channelized Hotelling observer (CHO) applied to the task of detecting a lesion at a known image location. It is assumed that signal-present and signal-absent images follow multivariate normal distributions with the same covariance matrix. The Bayesian approach results in a posterior distribution for the AUC of the CHO which provides in addition a complete characterization of the uncertainty of this figure of merit. The approach is illustrated by its application to both simulated and experimental data.

  20. CT image segmentation using FEM with optimized boundary condition.

    Directory of Open Access Journals (Sweden)

    Hiroyuki Hishida

    Full Text Available The authors propose a CT image segmentation method using structural analysis that is useful for objects with structural dynamic characteristics. Motivation of our research is from the area of genetic activity. In order to reveal the roles of genes, it is necessary to create mutant mice and measure differences among them by scanning their skeletons with an X-ray CT scanner. The CT image needs to be manually segmented into pieces of the bones. It is a very time consuming to manually segment many mutant mouse models in order to reveal the roles of genes. It is desirable to make this segmentation procedure automatic. Although numerous papers in the past have proposed segmentation techniques, no general segmentation method for skeletons of living creatures has been established. Against this background, the authors propose a segmentation method based on the concept of destruction analogy. To realize this concept, structural analysis is performed using the finite element method (FEM, as structurally weak areas can be expected to break under conditions of stress. The contribution of the method is its novelty, as no studies have so far used structural analysis for image segmentation. The method's implementation involves three steps. First, finite elements are created directly from the pixels of a CT image, and then candidates are also selected in areas where segmentation is thought to be appropriate. The second step involves destruction analogy to find a single candidate with high strain chosen as the segmentation target. The boundary conditions for FEM are also set automatically. Then, destruction analogy is implemented by replacing pixels with high strain as background ones, and this process is iterated until object is decomposed into two parts. Here, CT image segmentation is demonstrated using various types of CT imagery.

  1. CT scan of the brain (image)

    Science.gov (United States)

    ... CAT scan (computed tomography) is a much more sensitive imaging technique than x-ray, allowing high definition not only of the bony structures, but of the soft tissues. Clear images of organs such as the brain, muscles, joint structures, veins ...

  2. CEREBRAL HYDATID DISEASE: CT AND MR IMAGING FINDINGS

    Directory of Open Access Journals (Sweden)

    Ajay

    2014-10-01

    Full Text Available OBJECTIVE: Cerebral hydatid disease is very rare, representing only 2% of all cerebral space occupying lesions even in the countries where the disease is endemic. The aim of this paper is to describe the characteristic features of cerebral hydatid disease in computed tomography (CT and magnetic resonance imaging (MRI. METHODS: Here is a case 25yr/m who presented to neurosurgery OPD with complaints of headache, vomiting, right sided weakness and seizures for 2 weeks. CT and MRI were the imaging modalities to reach the diagnosis which was pathologically confirmed postoperatively as hydatid disease. RESULTS: CT and MR imaging findings of E. granulosus lesions were well defined, smooth thin-walled, spherical, homogeneous cystic lesions with no contrast enhancement, no calcification, and no surrounding oedema. CONCLUSION: Although cystic cerebral hydatid disease is well demonstrated by CT and MR examinations, CT is superior in detecting calcification in the cyst, when present, MR is better in demonstrating cyst capsule, detecting multiplicity and defining the anatomic relationship of the lesion with the adjacent structures, and it is more helpful in surgical planning.

  3. Disease quantification on PET/CT images without object delineation

    Science.gov (United States)

    Tong, Yubing; Udupa, Jayaram K.; Odhner, Dewey; Wu, Caiyun; Fitzpatrick, Danielle; Winchell, Nicole; Schuster, Stephen J.; Torigian, Drew A.

    2017-03-01

    The derivation of quantitative information from images to make quantitative radiology (QR) clinically practical continues to face a major image analysis hurdle because of image segmentation challenges. This paper presents a novel approach to disease quantification (DQ) via positron emission tomography/computed tomography (PET/CT) images that explores how to decouple DQ methods from explicit dependence on object segmentation through the use of only object recognition results to quantify disease burden. The concept of an object-dependent disease map is introduced to express disease severity without performing explicit delineation and partial volume correction of either objects or lesions. The parameters of the disease map are estimated from a set of training image data sets. The idea is illustrated on 20 lung lesions and 20 liver lesions derived from 18F-2-fluoro-2-deoxy-D-glucose (FDG)-PET/CT scans of patients with various types of cancers and also on 20 NEMA PET/CT phantom data sets. Our preliminary results show that, on phantom data sets, "disease burden" can be estimated to within 2% of known absolute true activity. Notwithstanding the difficulty in establishing true quantification on patient PET images, our results achieve 8% deviation from "true" estimates, with slightly larger deviations for small and diffuse lesions where establishing ground truth becomes really questionable, and smaller deviations for larger lesions where ground truth set up becomes more reliable. We are currently exploring extensions of the approach to include fully automated body-wide DQ, extensions to just CT or magnetic resonance imaging (MRI) alone, to PET/CT performed with radiotracers other than FDG, and other functional forms of disease maps.

  4. "Conventional" CT images from spectral measurements

    Science.gov (United States)

    Rajbhandary, Paurakh L.; Pelc, Norbert J.

    2016-03-01

    Spectral imaging systems need to be able to produce "conventional" images, and it's been shown that systems with energy discriminating detectors can achieve higher CNR than conventional systems by optimal weighting. Combining measured data in energy bins (EBs) and also combining basis material images have previously been proposed, but there are no studies systematically comparing the two methods. In this paper, we analytically evaluate the two methods for systems with ideal photon counting detectors using CNR and beam hardening (BH) artifact as metrics. For a 120-kVp polychromatic simulations of a water phantom with low contrast inserts, the difference of the optimal CNR between the two methods for the studied phantom is within 2%. For a polychromatic spectrum, beam-hardening artifacts are noticeable in EB weighted images (BH artifact of 3.8% for 8 EB and 6.9% for 2 EB), while weighted basis material images are free of such artifacts.

  5. PET/CT imaging in head and neck tumors; PET-CT-Bildgebung bei Kopf-Hals-Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J. [Universitaetsklinikum Bonn, Klinik und Poliklinik fuer Nuklearmedizin (Germany); Straehler-Pohl, H.J. [Universitaetsklinikum Bonn, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde (Germany); Jaeger, U. [Universitaetsklinikum Bonn, Radiologische Klinik (Germany)

    2004-11-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [German] Die Bestimmung der Wertigkeit der kombinierten PET-CT-Untersuchung zum Nachweis maligner Kopf-Hals-Tumoren und ihrer Metastasen. Bei 51 Patienten wurden Ganzkoerperuntersuchungen mit dem kombiniertem PET-CT-System durchgefuehrt. Die CT erfolgte ohne i.v. Kontrastmittelgabe. Die Ergebnisse wurden in ihrer diagnostischen Aussage einerseits getrennt fuer native CT- und FDG-PET-Bildgebung und andererseits fuer das fusionierte Bild verglichen. Von 153 Laesionen wurden 97 im CT und 136 im FDG-PET als maligne, 33 im CT und 7 im FDG-PET als malignitaetsverdaechtig, 23 im CT und 10 in der FDG-PET als benigne beurteilt. Die Anzahl der konkordanten Ergebnisse betrug 94 (61%), die der diskordanten 59 (39 %). Mit der PET-CT konnten alle Primaertumoren und Rezidive entdeckt werden, die Nachweisrate eines unbekannten Primaertumors betrug 45%. Im Vergleich zur alleinigen PET- oder CT-Untersuchung erhoehen sich bei der kombinierten PET-CT Sensitivitaet, Spezifitaet sowie die

  6. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  7. Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm.

    Science.gov (United States)

    Lubner, Meghan G; Pickhardt, Perry J; Tang, Jie; Chen, Guang-Hong

    2011-07-01

    To assess the effect of prior image constrained compressed sensing (PICCS) on noise reduction and image quality at low-dose computed tomography (CT). This HIPAA-compliant institutional review board-approved retrospective study was performed by using DICOM CT colonography data sets obtained in 20 adult patients. Informed consent was waived. Low-dose CT colonography was performed with 64-detector CT by using the standard protocol with mean effective dose per series of 3.06 mSv (range, 1.4-7.7 mSv). PICCS was applied to standard filtered back-projection (FBP) series. For FBP and PICCS series, mean and standard deviation (SD) of attenuation were obtained with 100-mm(2) circular region of interest (ROI) at six sites (240 soft-tissue, colonic gas, and subcutaneous fat measurements). Two abdominal radiologists reviewed two- and three-dimensional CT colonography displays and graded image quality with a five-point scale. Phantom studies were performed to compare spatial resolution and image quality between FBP and PICCS. Mean image noise and image quality scores were calculated and compared for clinical and phantom data sets. Bland-Altman, generalized estimating equation regression model, and Student t tests were used to obtain limits of agreement and to compare noise ratios and subjective image quality. Mean SD of attenuation (image noise) for ROIs was 38.0 for FBP and 12.2 for PICCS, corresponding to a noise-reduction factor of 3.1 (P < .001). Average noise reduction was 3.3 for soft tissue, 2.8 for air, and 3.0 for fat attenuation. Attenuation did not substantially change between FBP and PICCS images. Average two-dimensional image quality was 2.45 for FBP and 3.4 for PICCS (P < .001). Average three-dimensional image quality at three sites in the colon was 3.5 for FBP and 3.7 for PICCS (P = .34). Phantom data sets revealed no loss of spatial resolution in a line phantom and reduced noise in a liver tumor phantom when PICCS was compared with FBP. Application of PICCS to

  8. Image analysis of the inner ear with CT and MR imaging; Pre-operative assessment for cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Kohzoh; Takeda, Hidehiko; Mutoh, Naoko; Miyakawa, Kohichi (Toranomon Hospital, Tokyo (Japan)); Yukawa, Kumiko; Funasaka, Sohtaro

    1992-06-01

    Recent progress in magnetic resonance imaging (MRI) has made it possible to obtain detailed images of the inner ear by delineating the lymphatic fluid within the labyrinth. We analyzed CT scans and MR imaging in 70 ears manifesting profound deafness owing to inner ear lesions and compared their detective ability for inner ear lesions. The following results were obtained. CT scan examination showed slight to extensive ossification of the labyrinth in six ears (9%), whereas MRI examination revealed low to absent signal intensity of the inner ear in nine ears (13%). Therefore, it was concluded that MRI is more sensitive in detecting abnormalities of the inner ear than CT scan. MRI provided useful information as to whether the cochlear turn is filled with lymphatic fluid or obstructed. This point was one of the greatest advantages of MRI over CT scan. Abnormal findings in either or both the CT scan and the MRI were detected in suppurative labyrinthitis occurring secondary to chronic otitis media, bacterial meningitis and in inner ear trauma. However, such abnormal findings were not detected in patients with idiopathic progressive sensorineural hearing loss, ototoxity or sudden deafness. These findings should be taken into consideration in pre-operative assessment of cochlear implant candidates. (author).

  9. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof [Heidelberg Univ. (Germany). Dept. of Obstetrics and Gynecology; Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter [Heidelberg Univ. (Germany). Dept. of Diagnostic and Interventional Radiology

    2011-10-15

    The goal of this article is to provide an overview of diagnostic standard operating procedures for both clinical and imaging assessment of cervical and endometrial carcinoma, sarcoma of the uterus, and primary pelvic non-Hodgkin's lymphoma. The literature was reviewed for methods used to diagnose malignancies in the female pelvis with a special focus on the role of MRI as the imaging method of choice. Furthermore, CT findings and staging criteria for the mentioned malignancies are also provided. Whereas ultrasound still remains the imaging modality of choice in clinical practice for the early diagnosis of female pelvic malignancies, MRI is more frequently recognized as a diagnostic tool for its accuracy in tumor identification. MRI also plays a crucial role in the 3D pretreatment planning for brachytherapy especially in cervical cancer. In the future, PET/CT might achieve an important role for staging lymph nodes or distant metastases as well as tumor recurrence.

  10. Osteosarcoma of the jaws: demographic and CT imaging features

    Science.gov (United States)

    Wang, S; Shi, H; Yu, Q

    2012-01-01

    Objective The aim of this study was to evaluate the patient demographic and CT imaging findings of primary osteosarcoma of the jaws. Methods 88 primary osteosarcomas of the jaws histopathologically diagnosed during 1997–2007 were reviewed. 21 cases of CT images were reviewed. Results Of 88 patients, 51 (58%) had tumours in the mandible and 37 (42%) in the maxilla. The mean age was 37.8 years (range 9–80 years). The male-to-female ratio was 1.32:1. The mean age of patients with mandibular lesions was 41.04 years and in those with maxillary lesions it was 33.3 years. CT imaging findings were available in 21 patients. In the maxilla (n = 9), all tumours (100%) arose from the alveolar ridge. In the mandible (n = 12), most tumours (9 cases, 75%), arose from the ramus and/or condyle. All except two lesions had the epicentrum within the medullary cavity of the involved bone. The presence of periosteal reaction was demonstrated in 13 cases (62%). Soft-tissue extension was present in 18 lesions (86%), with calcification identified in 13 (72%). Conclusions This study provides age, sex distribution, location and CT imaging features of primary osteosarcoma of the jaws. PMID:22074870

  11. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  12. Software windows for the display of CT-images

    Energy Technology Data Exchange (ETDEWEB)

    Gell, G.; Sager, W.D.; Toelly, E.

    1983-03-01

    Software windows are a flexible and general method for defining arbitrary functions for the mapping of Hounsfield-numbers of CT-scans on to the grey levels of the display image. The method which is illustrated with the aid of a few examples has been implemented on an EMI viewing console.

  13. Computer aided detection of oral lesions on CT images

    Science.gov (United States)

    Galib, S.; Islam, F.; Abir, M.; Lee, H. K.

    2015-12-01

    Oral lesions are important findings on computed tomography (CT) images. In this study, a fully automatic method to detect oral lesions in mandibular region from dental CT images is proposed. Two methods were developed to recognize two types of lesions namely (1) Close border (CB) lesions and (2) Open border (OB) lesions, which cover most of the lesion types that can be found on CT images. For the detection of CB lesions, fifteen features were extracted from each initial lesion candidates and multi layer perceptron (MLP) neural network was used to classify suspicious regions. Moreover, OB lesions were detected using a rule based image processing method, where no feature extraction or classification algorithm were used. The results were validated using a CT dataset of 52 patients, where 22 patients had abnormalities and 30 patients were normal. Using non-training dataset, CB detection algorithm yielded 71% sensitivity with 0.31 false positives per patient. Furthermore, OB detection algorithm achieved 100% sensitivity with 0.13 false positives per patient. Results suggest that, the proposed framework, which consists of two methods, has the potential to be used in clinical context, and assist radiologists for better diagnosis.

  14. Hydatid disease of the spleen; Ultrasonography, CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N. von; Stridbeck, H. (Dept. of Diagnostic Radiology, King Faisal Specialist Hospital, and Research Center, Riyadh (Saudi Arabia) Lund Univ. Hospital (Sweden))

    1992-09-01

    Seven patients with hydatid disease of the spleen were examined by radiography, ultrasound, CT, and in one case MR imaging. The observations were confirmed by patho-anatomic findings except in 2 patients where high indirect hemagglutination tests confirmed the diagnosis. (orig./MG).

  15. Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner

    Science.gov (United States)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.

    2006-03-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.

  16. 3D SPECT/CT fusion using image data projection of bone SPECT onto 3D volume-rendered CT images: feasibility and clinical impact in the diagnosis of bone metastasis.

    Science.gov (United States)

    Ogata, Yuji; Nakahara, Tadaki; Ode, Kenichi; Matsusaka, Yohji; Katagiri, Mari; Iwabuchi, Yu; Itoh, Kazunari; Ichimura, Akira; Jinzaki, Masahiro

    2017-05-01

    We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness. Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale. Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB

  17. Reliability of visual assessment of non-contrast CT, CT angiography source images and CT perfusion in patients with suspected ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Tom van Seeters

    Full Text Available BACKGROUND AND PURPOSE: Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA rule and the Alberta Stroke Program Early CT Score (ASPECTS for different CT modalities in patients suspected of acute ischemic stroke. METHODS: We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement. RESULTS: Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps. Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps. CONCLUSION: Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging.

  18. CT and MR imaging findings of xanthogranulomatous cholecystitis: correlation with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shuto, R.; Kiyosue, H.; Komatsu, E.; Matsumoto, S.; Mori, H. [Oita Medical Univ. (Japan). Dept. of Radiology; Kawano, K. [Oita Medical Univ. (Japan). Dept. of First Surgery; Kondo, Y.; Yokoyama, S. [Oita Medical Univ. (Japan). Dept. of First Pathology

    2004-03-01

    The aim of this study was to evaluate CT and MRI findings in xanthogranulomatous cholecystitis (XGC) and to correlate the imaging findings with various pathologic parameters. The study included 13 patients with histopathologically confirmed XGC. The CT (n=13) and MRI (n=5) obtained in these patients were evaluated retrospectively. On CT, low-attenuation areas in the wall of XGC correlated with foam and inflammatory cells or necrosis and/or abscess in XGC. Areas of iso- to slightly high signal intensity on T2-weighted images, showing slight enhancement at early phase and strong enhancement at last phase on dynamic study, corresponded with areas of abundant xanthogranulomas. Areas with very high signal intensity on T2-weighted images without enhancement corresponded with necrosis and/or abscesses. Luminal surface enhancement (LSE) of gallbladder wall represented preservation of the epithelial layer. The early-enhanced areas of the liver bed on dynamic CT and MR images corresponded with accumulation of inflammatory cells and abundant fibrosis. Our results indicate that CT and MRI findings correlate well with the histopathologic findings of XGC.

  19. Evaluation of reformatted sagittal CT images for measurement of condylar position. Comparison between original axial and coronal images

    Energy Technology Data Exchange (ETDEWEB)

    Hiruma, Takayoshi; Funato, Masahiko; Suganuma, Takeshi; Shinya, Akiyuki; Furuya, Ryoichi; Kawawa, Tadaharu; Seki, Kenji; Okano, Tomohiro [Showa Univ., Tokyo (Japan). School of Dentistry

    1995-09-01

    Accurate measurement of the condylar position is important for diagnosis and treatment of temporomandibular joint dysfunction. Conventional radiographic techniques have been used for this purpose and the recent advance of computed tomography (CT) is applicable to temporomandibular joints. The accuracy of CT in the measurement of the condylar position is still unclear. The purpose of this study was to evaluate the measurement accuracy of the condylar position on reformatted sagittal CT images. Six TMJs obtained from dried skulls were used. The TMJs were examined using a CT scanner with 1 mm thickness/interval in the axial and coronal directions. The visibility of the condyle and fossa on the reformatted sagittal images created were evaluated by measuring the joint space defined in our study. The results were as follows: (1) The superior surface of the condyle and the deepest part of the fossa were obscured in the reformatted images created from the axial scan and coronal scan projected at 60deg to the F-H plane. (2) The reformatted images from the coronal scan projected at 90deg, 80deg or 70deg to the F-H plane clearly depicted the condyle and fossa, the reproducibility of the measurement on these images mentioned above was less than 0.1 mm. The results indicated that the coronal scan from 90deg to 70deg to the F-H plane is more accurate than the axial scan for determining the condylar position on the reformatted sagittal images. (author).

  20. Fast and Automatic Ultrasound Simulation from CT Images

    OpenAIRE

    Weijian Cong; Jian Yang; Yue Liu; Yongtian Wang

    2013-01-01

    Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of...

  1. Multi-material decomposition of spectral CT images

    Science.gov (United States)

    Mendonça, Paulo R. S.; Bhotika, Rahul; Maddah, Mahnaz; Thomsen, Brian; Dutta, Sandeep; Licato, Paul E.; Joshi, Mukta C.

    2010-04-01

    Spectral Computed Tomography (Spectral CT), and in particular fast kVp switching dual-energy computed tomography, is an imaging modality that extends the capabilities of conventional computed tomography (CT). Spectral CT enables the estimation of the full linear attenuation curve of the imaged subject at each voxel in the CT volume, instead of a scalar image in Hounsfield units. Because the space of linear attenuation curves in the energy ranges of medical applications can be accurately described through a two-dimensional manifold, this decomposition procedure would be, in principle, limited to two materials. This paper describes an algorithm that overcomes this limitation, allowing for the estimation of N-tuples of material-decomposed images. The algorithm works by assuming that the mixing of substances and tissue types in the human body has the physicochemical properties of an ideal solution, which yields a model for the density of the imaged material mix. Under this model the mass attenuation curve of each voxel in the image can be estimated, immediately resulting in a material-decomposed image triplet. Decomposition into an arbitrary number of pre-selected materials can be achieved by automatically selecting adequate triplets from an application-specific material library. The decomposition is expressed in terms of the volume fractions of each constituent material in the mix; this provides for a straightforward, physically meaningful interpretation of the data. One important application of this technique is in the digital removal of contrast agent from a dual-energy exam, producing a virtual nonenhanced image, as well as in the quantification of the concentration of contrast observed in a targeted region, thus providing an accurate measure of tissue perfusion.

  2. Generation of synthetic CT data using patient specific daily MR image data and image registration

    Science.gov (United States)

    Melanie Kraus, Kim; Jäkel, Oliver; Niebuhr, Nina I.; Pfaffenberger, Asja

    2017-02-01

    To fully exploit the advantages of magnetic resonance imaging (MRI) for radiotherapy (RT) treatment planning, a method is required to overcome the problem of lacking electron density information. We aim to establish and evaluate a new method for computed tomography (CT) data generation based on MRI and image registration. The thereby generated CT data is used for dose accumulation. We developed a process flow based on an initial pair of rigidly co-registered CT and T2-weighted MR image representing the same anatomical situation. Deformable image registration using anatomical landmarks is performed between the initial MRI data and daily MR images. The resulting transformation is applied to the initial CT, thus fractional CT data is generated. Furthermore, the dose for a photon intensity modulated RT (IMRT) or intensity modulated proton therapy (IMPT) plan is calculated on the generated fractional CT and accumulated on the initial CT via inverse transformation. The method is evaluated by the use of phantom CT and MRI data. Quantitative validation is performed by evaluation of the mean absolute error (MAE) between the measured and the generated CT. The effect on dose accumulation is examined by means of dose-volume parameters. One patient case is presented to demonstrate the applicability of the method introduced here. Overall, CT data derivation lead to MAEs with a median of 37.0 HU ranging from 29.9 to 66.6 HU for all investigated tissues. The accuracy of image registration showed to be limited in the case of unexpected air cavities and at tissue boundaries. The comparisons of dose distributions based on measured and generated CT data agree well with the published literature. Differences in dose volume parameters kept within 1.6% and 3.2% for photon and proton RT, respectively. The method presented here is particularly suited for application in adaptive RT in current clinical routine, since only minor additional technical equipment is required.

  3. Improved diagnosis of actively bleeding aneurysm on CT angiography using delayed CT images

    Energy Technology Data Exchange (ETDEWEB)

    Kathuria, Sudhir, E-mail: skathur2@jhmi.edu [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Division of Interventional Neuroradiology, Department of Neurology and Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Deveikis, John P.; Westesson, Per-Lennart [Division of Diagnostic and Interventional Neuroradiology, Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY 14642 (United States); Gandhi, Dheeraj [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Division of Interventional Neuroradiology, Department of Neurology and Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD (United States)

    2011-08-15

    Computed tomographic angiography (CTA) is being increasingly utilized in the non-invasive diagnosis of aneurysmal subarachnoid hemorrhage (SAH). There are emerging reports of diagnosis of active aneurysmal bleeding on CTA, furthering our understanding of imaging features of active extravasation on cross-sectional studies. We demonstrate imaging characteristics of two such cases of active contrast extravasation from intracranial aneurysms. Additionally, we demonstrate that delayed CT images greatly improve the confidence of this diagnosis by demonstrating pooling of contrast in the subarachnoid space. Prompt recognition and management can improve prognosis of this potentially lethal condition.

  4. Image registration/fusion software for PET and CT/MRI by using simultaneous emission and transmission scans

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Keishi; Amano, Masaharu; Sato, Tomohiko [Shimadzu Corp., Medical Systems Division, Kyoto (Japan); Okumura, Takeshi [Shimadzu Corp., Technology Research Laboratory, Kyoto (Japan); Konishi, Norihiro; Komatsu, Masahiko [Shimadzu System Development Corp., Kyoto (Japan)

    2003-06-01

    When PET (positron emission tomography) is used for oncology studies, it is important to register and over-lay PET images with the images of other anatomical modalities, such as those obtained by CT (computed tomography) or MRI (magnetic resonance imaging), in order for the lesions to be anatomically located with high accuracy. The Shimadzu SET-2000W Series PET scanners provide simultaneous acquisition of emission and transmission data, which is capable of complete spatial alignment of both functional and attenuation images. This report describes our newly developed image registration/fusion software, which reformats PET emission images to the CT/MRI grid by using the transform matrix obtained by matching PET transmission images with CT/MRI images. Transmission images are registered and fused either automatically or manually, through 3-dimensional rotation and translation, with the transaxial, sagittal, and coronal fused images being monitored on the screen. This new method permits sufficiently accurate registration and efficient data processing with promoting effective use of CT/MRI images of the DICOM format, without using markers in data acquisition or any special equipment, such as a combined PET/CT scanner. (author)

  5. [CT coronary angiography: indications, image acquisition, and interpretation].

    Science.gov (United States)

    Schoepf, U J; Thilo, C; Fernández, M J; Costello, P

    2008-01-01

    Intense scientific and clinical evaluation have brought about great improvements in cardiac CT. This is no longer merely an experimental technique, rather it has become a clinical application that is ready to fulfill its promise of replacing invasive cardiac catheterization in certain patient populations. Among the proven indications is the evaluation of patients with atypical chest pain, the morphological evaluation of the coronary arteries in cases of suspected congenital anomalies, and before surgical intervention, as well as the evaluation of coronary revascularizations. The use of CT angiography for the exhaustive evaluation of cardiac and non-cardiac pathology in patients with acute chest pain in the emergency department is currently being investigated. Because the heart is continuously moving, CT coronary angiography represents a greater technical challenge than other applications of CT. On the other hand, rapid technical development requires acquisition protocols to be adjusted constantly. However, users that know the general techniques of computed tomography can overcome these challenges. The aim of this article is to provide those interested and involved in CT angiography with a manual to enable them to follow our method step by step. We include considerations regarding the correct selection of patients, patient medication, radiological protection, contrast enhancement, acquisition and reconstruction parameters, image display, image analysis techniques, and the radiological report. Our recommendations are based on our experience, which runs from the evolution of multiple-row detector CT scanners for cardiac applications from its beginnings to the most modern presentations of advanced acquisition modalities, including dual-source CT, which we consider to be the precursor of this test in routine clinical practice.

  6. Reconstruction of CT images by the Bayes- back projection method

    CERN Document Server

    Haruyama, M; Takase, M; Tobita, H

    2002-01-01

    In the course of research on quantitative assay of non-destructive measurement of radioactive waste, the have developed a unique program based on the Bayesian theory for reconstruction of transmission computed tomography (TCT) image. The reconstruction of cross-section images in the CT technology usually employs the Filtered Back Projection method. The new imaging reconstruction program reported here is based on the Bayesian Back Projection method, and it has a function of iterative improvement images by every step of measurement. Namely, this method has the capability of prompt display of a cross-section image corresponding to each angled projection data from every measurement. Hence, it is possible to observe an improved cross-section view by reflecting each projection data in almost real time. From the basic theory of Baysian Back Projection method, it can be not only applied to CT types of 1st, 2nd, and 3rd generation. This reported deals with a reconstruction program of cross-section images in the CT of ...

  7. CT Metal Artifact Reduction Method Based on Improved Image Segmentation and Sinogram In-Painting

    Directory of Open Access Journals (Sweden)

    Yang Chen

    2012-01-01

    Full Text Available The streak artifacts caused by metal implants degrade the image quality and limit the applications of CT imaging. The standard method used to reduce these metallic artifacts often consists of interpolating the missing projection data but the result is often a loss of image quality with additional artifacts in the whole image. This paper proposes a new strategy based on a three-stage process: (1 the application of a large-scale non local means filter (LS-NLM to suppress the noise and enhance the original CT image, (2 the segmentation of metal artifacts and metallic objects using a mutual information maximized segmentation algorithm (MIMS, (3 a modified exemplar-based in-painting technique to restore the corrupted projection data in sinogram. The final corrected image is then obtained by merging the segmented metallic object image with the filtered back-projection (FBP reconstructed image from the in-painted sinogram. Quantitative and qualitative experiments have been conducted on both a simulated phantom and clinical CT images and a comparative study has been led with Bal's algorithm that proposed a similar segmentation-based method.

  8. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  9. Esthesioneuroblastoma methods of intracranial extension: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Tian; Xu, Yi-Kai; Jia, Fei-Ge; Yang, Rui-Meng; Feng, Jie; Ye, Xiang-Hua; Qiu, Ying-Wei [Southern Medical University, Department of Medical Imaging Center, Nan Fang Hospital, Guangzhou, Guangdong (China); Li, Long [Chinese People' s Armed Police Forces, Department of Radiology, Guangdong Provincial Corps Hospital, Guangzhou (China); Duan, Gang; Wu, Yuan-Kui [Southern Medical University, Department of Radiology, Nan Fang Hospital, Guangzhou (China); Li, Hua-Yu [No. 458 Hospital of PLA, Department of Medical Imaging Center, Guangzhou (China)

    2009-12-15

    Esthesioneuroblastoma (ENB) is an aggressive neuroectodermal malignancy in the upper nasal cavity with local infiltration and lymphatic or hematogenous metastasis. The purpose of this paper is to document three types of direct intracranial extensions by ENB using computed tomography (CT) and magnetic resonance imaging (MRI). Eleven patients with pathologically confirmed ENB were admitted in our hospital between December 2002 and December 2008. Their magnetic resonance (MR; n = 10) and CT (n = 8) images were retrospectively reviewed, and particular attention was paid to tumor location and extension, enhancement pattern, cervical lymph node metastasis, and Kadish stage. The majority of patients were male (8/11) with Kadish stage C tumor (10/11). Three types of direct intracranial extension by ENBs were put forward according to their MR and CT findings. The primary tumors were well-defined soft-tissue masses centered in the roof of the nasal cavity eroding into the paranasal sinuses (11/11), the contralateral nasal cavity (4/11), the cranial cavity (5/11), and the fossa orbitalis (3/11). The tumor parenchyma were hypointensity on T1-weighted images, heterogeneous hyperintensity on T2-weighted images, and isodensity or slight hyperdensity on CT images with scattered necroses (4/11) and marginal cysts(4/11). Their enhancements were significant and inhomogeneous. Cervical lymph nodes metastases were observed in four patients (4/11), but no pathologically proved distant metastasis was observed. Three types of direct intracranial extensions by ENB can be found on CT and MRI: cranio-orbital-nasal-communicating ENB, cranio-nasal-communicating ENB, and orbital-nasal-communicating ENB. (orig.)

  10. Hybrid detection of lung nodules on CT scan images

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Lin; Tan, Yongqiang; Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-09-15

    Purpose: The diversity of lung nodules poses difficulty for the current computer-aided diagnostic (CAD) schemes for lung nodule detection on computed tomography (CT) scan images, especially in large-scale CT screening studies. We proposed a novel CAD scheme based on a hybrid method to address the challenges of detection in diverse lung nodules. Methods: The hybrid method proposed in this paper integrates several existing and widely used algorithms in the field of nodule detection, including morphological operation, dot-enhancement based on Hessian matrix, fuzzy connectedness segmentation, local density maximum algorithm, geodesic distance map, and regression tree classification. All of the adopted algorithms were organized into tree structures with multi-nodes. Each node in the tree structure aimed to deal with one type of lung nodule. Results: The method has been evaluated on 294 CT scans from the Lung Image Database Consortium (LIDC) dataset. The CT scans were randomly divided into two independent subsets: a training set (196 scans) and a test set (98 scans). In total, the 294 CT scans contained 631 lung nodules, which were annotated by at least two radiologists participating in the LIDC project. The sensitivity and false positive per scan for the training set were 87% and 2.61%. The sensitivity and false positive per scan for the testing set were 85.2% and 3.13%. Conclusions: The proposed hybrid method yielded high performance on the evaluation dataset and exhibits advantages over existing CAD schemes. We believe that the present method would be useful for a wide variety of CT imaging protocols used in both routine diagnosis and screening studies.

  11. Implementation of efficient image reconstruction for CT

    Institute of Scientific and Technical Information of China (English)

    Jie Liu; Guangfei Wang

    2005-01-01

    @@ The operational procedures for efficiently reconstructing the two-dimensional image of a body by the filtered back projection are described in this paper. The projections are interpolated for four times of original projection by zero-padding the original projection in frequency-domain and then inverse fast Fourier transform (FFT) is taken to improve accuracy.

  12. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, Dae Cheol [Dept. of Radiological Science, College of Health Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2016-06-15

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

  13. Dysplastic gangliocytoma (Lhermitte-Duclos disease): CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vieco, P.T.; Del Carpio-O' Donovan, R.; Melanson, D. (Montreal Neurological Hospital, PQ (Canada). Dept. of Diagnostic Radiology); Montes, J. (Montreal Children' s Hospital, PQ (Canada). Dept. of Neurosurgery); O' Gorman, A.M. (Montreal Children' s Hospital, PQ (Canada). Dept. of Radiology); Meagher-Villemure, K. (Montreal Children' s Hospital, PQ (Canada). Dept. of Pathology)

    1992-09-01

    Dysplastic gangliocytoma (Lhermitte-Duclos disease) is a rare entity. Usually presenting as a posterior fossa mass, dyplastic gangliocytoma is not a true neoplasm but a hard-to-characterize lesion that may represent an abnormality of cell migration or a phacomatosis. Previous reports of CT findings are rare in the radiologic literature, and high-field (1.5 Tesla) MR images have never been described in the pediatric age group. We present a case of dysplastic gangliocytoma in a one-year-old boy with CT and MR findings. (orig.).

  14. Interapophyseal joint synovial cyst of lumbar spine. CT scan and MR imaging correlation in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Granat, O.; Jeanbourquin,D.; Perfettini, C.; Pernot, P.; Ducolombier, A.; Cosnard, G.

    1987-05-01

    Two patients presenting with L5 radiculagia were investigated by CT scan imaging. The origin of the pain was determined with certitude as arising from intraspinal development of an interapophyseal synovial cyst. Examination of the two cases by MR imaging provided conflicting results: in one patient images obtained by MR were not contributive and the synovial cyst would probably have been missed while in the other patient images were specific and very sensitive for diagnosis of interapophyseal synovial lesions. Treatment was surgical in both cases.

  15. Lack of Anatomical Concordance between Preablation and Postablation CT Images: A Risk Factor Related to Ablation Site Recurrence.

    Science.gov (United States)

    Kele, Petra G; Van der Jagt, Eric J; Krabbe, Paul F M; de Jong, Koert P

    2012-01-01

    Objective. Variation in the position of the liver between preablation and postablation CT images hampers assessment of treatment of colorectal liver metastasis (CRLM). The aim of this study was to test the hypothesis that discordant preablation and postablation imaging is associated with more ablation site recurrences (ASRs). Methods. Patients with CRLM were included. Index-tumor size, location, number, RFA approachs and ablative margins were obtained on CT scans. Preablation and postablation CT images were assigned a "Similarity of Positioning Score" (SiPS). A suitable cutoff was determined. Images were classified as identical (SiPS-id) or nonidentical (SiPS-diff). ASR was identified prospectively on follow-up imaging. Results. Forty-seven patients with 97 tumors underwent 64 RFA procedures (39 patients/63 tumors open RFA, 25 patients/34 tumours CT-targeted RFA, 12 patients underwent >1 RFA). Images of 52 (54%) ablation sites were classified as SiPS-id, 45 (46%) as SiPS-diff. Index-tumor size, tumor location and number, concomitant partial hepatectomy, and RFA approach did not influence the SiPS. ASR developed in 11/47 (23%) patients and 20/97 (21%) tumours. ASR occurred less frequently after open RFA than after CT targeted RFA (P 20 mm and CT-targeted RFA as independent risk factors for ASR. Conclusion. Variation in anatomical concordance between preablation and postablation images, index-tumor size, and a CT-targeted approach are risk factors for ASR in CRLM.

  16. Comparison of quantitative myocardial perfusion imaging CT to fluorescent microsphere-based flow from high-resolution cryo-images

    Science.gov (United States)

    Eck, Brendan L.; Fahmi, Rachid; Levi, Jacob; Fares, Anas; Wu, Hao; Li, Yuemeng; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    Myocardial perfusion imaging using CT (MPI-CT) has the potential to provide quantitative measures of myocardial blood flow (MBF) which can aid the diagnosis of coronary artery disease. We evaluated the quantitative accuracy of MPI-CT in a porcine model of balloon-induced LAD coronary artery ischemia guided by fractional flow reserve (FFR). We quantified MBF at baseline (FFR=1.0) and under moderate ischemia (FFR=0.7) using MPI-CT and compared to fluorescent microsphere-based MBF from high-resolution cryo-images. Dynamic, contrast-enhanced CT images were obtained using a spectral detector CT (Philips Healthcare). Projection-based mono-energetic images were reconstructed and processed to obtain MBF. Three MBF quantification approaches were evaluated: singular value decomposition (SVD) with fixed Tikhonov regularization (ThSVD), SVD with regularization determined by the L-Curve criterion (LSVD), and Johnson-Wilson parameter estimation (JW). The three approaches over-estimated MBF compared to cryo-images. JW produced the most accurate MBF, with average error 33.3+/-19.2mL/min/100g, whereas LSVD and ThSVD had greater over-estimation, 59.5+/-28.3mL/min/100g and 78.3+/-25.6 mL/min/100g, respectively. Relative blood flow as assessed by a flow ratio of LAD-to-remote myocardium was strongly correlated between JW and cryo-imaging, with R2=0.97, compared to R2=0.88 and 0.78 for LSVD and ThSVD, respectively. We assessed tissue impulse response functions (IRFs) from each approach for sources of error. While JW was constrained to physiologic solutions, both LSVD and ThSVD produced IRFs with non-physiologic properties due to noise. The L-curve provided noise-adaptive regularization but did not eliminate non-physiologic IRF properties or optimize for MBF accuracy. These findings suggest that model-based MPI-CT approaches may be more appropriate for quantitative MBF estimation and that cryo-imaging can support the development of MPI-CT by providing spatial distributions of MBF.

  17. A study on the effect of CT imaging acquisition parameters on lung nodule image interpretation

    Science.gov (United States)

    Yu, Shirley J.; Wantroba, Joseph S.; Raicu, Daniela S.; Furst, Jacob D.; Channin, David S.; Armato, Samuel G., III

    2009-02-01

    Most Computer-Aided Diagnosis (CAD) research studies are performed using a single type of Computer Tomography (CT) scanner and therefore, do not take into account the effect of differences in the imaging acquisition scanner parameters. In this paper, we present a study on the effect of the CT parameters on the low-level image features automatically extracted from CT images for lung nodule interpretation. The study is an extension of our previous study where we showed that image features can be used to predict semantic characteristics of lung nodules such as margin, lobulation, spiculation, and texture. Using the Lung Image Data Consortium (LIDC) dataset, we propose to integrate the imaging acquisition parameters with the low-level image features to generate classification models for the nodules' semantic characteristics. Our preliminary results identify seven CT parameters (convolution kernel, reconstruction diameter, exposure, nodule location along the z-axis, distance source to patient, slice thickness, and kVp) as influential in producing classification rules for the LIDC semantic characteristics. Further post-processing analysis, which included running box plots and binning of values, identified four CT parameters: distance source to patient, kVp, nodule location, and rescale intercept. The identification of these parameters will create the premises to normalize the image features across different scanners and, in the long run, generate automatic rules for lung nodules interpretation independently of the CT scanner types.

  18. Imaging in covert ectopic ACTH secretion: a CT pictorial review

    Energy Technology Data Exchange (ETDEWEB)

    Sookur, Paul A.; Sahdev, Anju; Rockall, Andrea G.; Reznek, Rodney H. [St Bartholomew' s Hospital, Department of Academic Radiology, Dominion House, London (United Kingdom); Isidori, Andrea M. [Sapienza University of Rome, Department of Medical Pathophysiology, Rome (Italy); Monson, John P.; Grossman, Ashley B. [St Bartholomew' s Hospital, Department of Endocrinology, London (United Kingdom)

    2009-05-15

    The syndrome of ectopic adrenocorticotrophin secretion (EAS) is rare and is due to excess adrenocorticotrophin (ACTH) production from a nonpituitary tumour. These tumours can be covert, where the tumours are not readily apparent, and very small making them challenging to image. It is clinically and biochemically difficult to distinguish between covert EAS and Cushing's disease. The first-line investigation in locating the source of ACTH production is computed tomography (CT). The aim of this pictorial review is to illustrate the likely covert sites and related imaging findings. We review the CT appearances of tumours resulting in covert EAS and the associated literature. The most common tumours were bronchial carcinoid tumours, which appear as small, well-defined, round or ovoid pulmonary lesions. Rarer causes included thymic carcinoids, gastrointestinal carcinoids and pancreatic neuroendocrine tumours. Awareness of the imaging characteristics will aid identification of the source of ACTH production and allow potentially curative surgical resection. (orig.)

  19. Automatic annotation of radiological observations in liver CT images.

    Science.gov (United States)

    Gimenez, Francisco; Xu, Jiajing; Liu, Yi; Liu, Tiffany; Beaulieu, Christopher; Rubin, Daniel; Napel, Sandy

    2012-01-01

    We aim to predict radiological observations using computationally-derived imaging features extracted from computed tomography (CT) images. We created a dataset of 79 CT images containing liver lesions identified and annotated by a radiologist using a controlled vocabulary of 76 semantic terms. Computationally-derived features were extracted describing intensity, texture, shape, and edge sharpness. Traditional logistic regression was compared to L(1)-regularized logistic regression (LASSO) in order to predict the radiological observations using computational features. The approach was evaluated by leave one out cross-validation. Informative radiological observations such as lesion enhancement, hypervascular attenuation, and homogeneous retention were predicted well by computational features. By exploiting relationships between computational and semantic features, this approach could lead to more accurate and efficient radiology reporting.

  20. FDG PET/CT imaging as a biomarker in lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Meignan, Michel; Itti, Emmanuel [Hopitaux Universitaires Henri Mondor, Paris-Est Creteil University, LYSA Imaging, Department of Nuclear Medicine, Creteil (France); Gallamini, Andrea [Nice University, Research, Innovation and Statistic Department, Antoine Lacassagne Cancer Center, Nice (France); Scientific Research Committee, S. Croce Hospital, Cuneo (Italy); Younes, Anas [Memorial Sloan Kettering Cancer Center, Lymphoma Service, New York, NY (United States)

    2015-04-01

    FDG PET/CT has changed the management of FDG-avid lymphoma and is now recommended as the imaging technique of choice for staging and restaging. The need for tailoring therapy to reduce toxicity in patients with a favourable outcome and for improving treatment in those with high-risk factors requires accurate diagnostic methods and a new prognostic algorithm to identify different risk categories. New drugs are used in relapsed/refractory patients. The role of FDG PET/CT as a biomarker in this context is summarized in this review. New trends in FDG metabolic imaging in lymphoma are addressed including metabolic tumour volume measurement at staging and integrative PET which combines PET data with clinical and molecular markers or other imaging techniques. The quantitative approach for response assessment which is under investigation and is used in large ongoing trials is compared with visual criteria. The place of FDG in the era of targeted therapy is discussed. (orig.)

  1. Fast and automatic ultrasound simulation from CT images.

    Science.gov (United States)

    Cong, Weijian; Yang, Jian; Liu, Yue; Wang, Yongtian

    2013-01-01

    Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  2. Fast and Automatic Ultrasound Simulation from CT Images

    Directory of Open Access Journals (Sweden)

    Weijian Cong

    2013-01-01

    Full Text Available Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  3. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report; Bildgebende Diagnostik des Klippel-Feil-Syndroms: Konventionelle Roentgenaufnahmen, CT und MRT. Fallbericht

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schubeus, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Menzhausen, L. [Abt. fuer Psychiatrie, Urban Krankenhaus, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1993-12-31

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [Deutsch] Anhand von zwei Patienten mit Klippel-Feil-Syndrom Typ II werden typische radiologische Befunde des Missbildungssyndroms im Bereich der Halswirbelsaeule und des kraniozervikalen Ueberganges dargestellt. Neben den konventionellen HWS-Roentgenaufnahmen und den konventionellen Schichtaufnahmen, wurden bei beiden Patienten ein CT der HWS und bei einem Patienten zusaetzlich ein MRT durchgefuehrt. Die Ergebnisse und Befunde der verschiedenen Untersuchungsverfahren werden einander gegenuebergestellt. (orig.)

  4. Hepatic CT Image Query Based on Threshold-based Classification Scheme with Gabor Features

    Institute of Scientific and Technical Information of China (English)

    JIANG Li-jun; LUO Yong-zing; ZHAO Jun; ZHUANG Tian-ge

    2008-01-01

    Hepatic computed tomography (CT) images with Gabor function were analyzed.Then a thresholdbased classification scheme was proposed using Gabor features and proceeded with the retrieval of the hepatic CT images.In our experiments,a batch of hepatic CT images containing several types of CT findings was used and compared with the Zhao's image classification scheme,support vector machines (SVM) scheme and threshold-based scheme.

  5. Nondestructive Evaluation of Hardwood Logs Using Automated Interpretation of CT Images

    Science.gov (United States)

    Daniel L. Schmoldt; Dongping Zhu; Richard W. Conners

    1993-01-01

    Computed tomography (CT) imaging is being used to examine the internal structure of hardwood logs. The following steps are used to automatically interpret CT images: (1) preprocessing to remove unwanted portions of the image, e.g., annual ring structure, (2) image-by-image segmentation to produce relatively homogeneous image areas, (3) volume growing to create volumes...

  6. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnaure, I.; Lovblad, K.O.; Vargas, M.I. [Geneva University Hospital, Department of Neuroradiology, Geneva 14 (Switzerland); Pollak, P.; Horvath, J.; Boex, C.; Burkhard, P. [Geneva University Hospital, Department of Neurology, Geneva (Switzerland); Momjian, S. [Geneva University Hospital, Department of Neurosurgery, Geneva (Switzerland); Remuinan, J. [Geneva University Hospital, Department of Radiology, Geneva (Switzerland)

    2015-09-15

    Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS. (orig.)

  7. Multislice CT brain image registration for perfusion studies

    Science.gov (United States)

    Lin, Zhong Min; Pohlman, Scott; Chandra, Shalabh

    2002-04-01

    During the last several years perfusion CT techniques have been developed as an effective technique for clinically evaluating cerebral hemodynamics. Perfusion CT techniques are capable of measurings functional parameters such as tissue perfusion, blood flow, blood volume, and mean transit time and are commonly used to evaluate stroke patients. However, the quality of functional images of the brain frequently suffers from patient head motion. Because the time window for an effective treatment of stroke patient is narrow, a fast motion correction is required. The purpose of the paper is to present a fast and accurate registration technique for motion correction of multi-slice CT and to demonstrate the effects of the registration on perfusion calculation.

  8. A general approach to liver lesion segmentation in CT images

    Science.gov (United States)

    Cao, Li; Udupa, Jayaram K.; Odhner, Dewey; Huang, Lidong; Tong, Yubing; Torigian, Drew A.

    2016-03-01

    Lesion segmentation has remained a challenge in different body regions. Generalizability is lacking in published methods as variability in results is common, even for a given organ and modality, such that it becomes difficult to establish standardized methods of disease quantification and reporting. This paper makes an attempt at a generalizable method based on classifying lesions along with their background into groups using clinically used visual attributes. Using an Iterative Relative Fuzzy Connectedness (IRFC) delineation engine, the ideas are implemented for the task of liver lesion segmentation in computed tomography (CT) images. For lesion groups with the same background properties, a few subjects are chosen as the training set to obtain the optimal IRFC parameters for the background tissue components. For lesion groups with similar foreground properties, optimal foreground parameters for IRFC are set as the median intensity value of the training lesion subset. To segment liver lesions belonging to a certain group, the devised method requires manual loading of the corresponding parameters, and correct setting of the foreground and background seeds. The segmentation is then completed in seconds. Segmentation accuracy and repeatability with respect to seed specification are evaluated. Accuracy is assessed by the assignment of a delineation quality score (DQS) to each case. Inter-operator repeatability is assessed by the difference between segmentations carried out independently by two operators. Experiments on 80 liver lesion cases show that the proposed method achieves a mean DQS score of 4.03 and inter-operator repeatability of 92.3%.

  9. Xenon-enhanced CT imaging of local pulmonary ventilation

    Science.gov (United States)

    Tajik, Jehangir K.; Tran, Binh Q.; Hoffman, Eric A.

    1996-04-01

    We are using the unique features of electron beam CT (EBCT) in conjunction with respiratory and cardiac gating to explore the use of non-radioactive xenon gas as a pulmonary ventilation contrast agent. The goal is to construct accurate and quantitative high-resolution maps of local pulmonary ventilation in humans. We are evaluating xenon-enhanced computed tomography in the pig model with dynamic tracer washout/dilution and single breath inhalation imaging protocols. Scanning is done via an EBCT scanner which offers 50 msec scan aperture speeds. CT attenuation coefficients (image gray scale value) show a linear increase with xenon concentration (r equals 0.99). We measure a 1.55 Hounsfield Unit (HU) enhancement (kV equals 130, mA equals 623) per percentage increase in xenon gas concentration giving an approximately 155 HU enhancement with 100% xenon gas concentration as measured in a plexiglass super-syringe. Early results indicate that a single breath (from functional residual capacity to total lung capacity) of 100% xenon gas provides an average 32 +/- 1.85 (SE) HU enhancement in the lung parenchyma (maximum 50 HU) and should not encounter unwanted xenon side effects. However, changes in lung density occurring during even short breath holds (as short as 10 seconds) may limit using a single breath technique to synchronous volumetric scanning, currently possible only with EBCT. Preliminary results indicate close agreement between measured regional xenon concentration-time curves and theoretical predictions for the same sample. More than 10 breaths with inspirations to as high as 25 cmH2O airway pressure were needed to clear tracer from all lung regions and some regions had nearly linear rather than mono-exponential clearance curves. When regional parenchymal xenon concentration-time curves were analyzed, vertical gradients in ventilation and redistribution of ventilation at higher inspiratory flow rates were consistent with known pulmonary physiology. We present

  10. Learning with distribution of optimized features for recognizing common CT imaging signs of lung diseases

    Science.gov (United States)

    Ma, Ling; Liu, Xiabi; Fei, Baowei

    2017-01-01

    Common CT imaging signs of lung diseases (CISLs) are defined as the imaging signs that frequently appear in lung CT images from patients. CISLs play important roles in the diagnosis of lung diseases. This paper proposes a novel learning method, namely learning with distribution of optimized feature (DOF), to effectively recognize the characteristics of CISLs. We improve the classification performance by learning the optimized features under different distributions. Specifically, we adopt the minimum spanning tree algorithm to capture the relationship between features and discriminant ability of features for selecting the most important features. To overcome the problem of various distributions in one CISL, we propose a hierarchical learning method. First, we use an unsupervised learning method to cluster samples into groups based on their distribution. Second, in each group, we use a supervised learning method to train a model based on their categories of CISLs. Finally, we obtain multiple classification decisions from multiple trained models and use majority voting to achieve the final decision. The proposed approach has been implemented on a set of 511 samples captured from human lung CT images and achieves a classification accuracy of 91.96%. The proposed DOF method is effective and can provide a useful tool for computer-aided diagnosis of lung diseases on CT images.

  11. Spindle cell lipoma of the head and neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Wook [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Ajou University School of Medicine, Department of Radiology, Suwon (Korea, Republic of); Kim, Hyung-Jin; Kim, Hye Jung; Cha, Ji Hoon; Kim, Sung Tae [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jinna [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2013-01-15

    Spindle cell lipoma (SCL) is an uncommon benign lipomatous tumor, most commonly occurring in the posterior neck and shoulder. The purpose of this study was to investigate the CT and MR imaging features of SCL in the head and neck. CT (n = 5) and MR (n = 3) images of seven patients (five men and two women; mean age, 54 years) with surgically proven SCL in the head and neck were retrospectively reviewed. The location and morphologic characteristics of SCL were documented as well. Six lesions were well-defined and located in the subcutaneous fat of the posterior neck (n = 4), anterior neck (n = 1), and buccal space (n = 1). One lesion was ill-defined and located deeply in the supraclavicular fossa, infiltrating the adjacent shoulder muscles. Intratumoral fat was identified in five lesions in various amounts. Compared with the adjacent subcutaneous fat, intratumoral fat was slightly hyperattenuated on CT scans and slightly hypointense on T1-weighted MR images. In five of six lesions in which postcontrast CT and/or MR images were obtained, significant enhancement was seen in the nonadipose component of the lesion. Various components of the adipose and nonadipose tissues may cause difficulty differentiating between SCL and other adipocytic tumors including liposarcoma radiologically. Although nonspecific, the radiologist should know the various imaging features of SCL, because the tumor can be cured by simple excision. (orig.)

  12. Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.

    Science.gov (United States)

    Li, Yongrui; Li, Ye; Jackson, Alan; Li, Xiaodong; Huang, Ning; Guo, Chunjie; Zhang, Huimao

    2017-01-01

    To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT. 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing. The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%. VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine

  13. Quantitative imaging of electron density and effective atomic number using phase contrast CT

    Energy Technology Data Exchange (ETDEWEB)

    Qi Zhihua; Zambelli, Joseph; Bevins, Nicholas; Chen Guanghong, E-mail: gchen7@wisc.ed [Department of Medical Physics, University of Wisconsin-Madison, WI 53705 (United States)

    2010-05-07

    Compared to single energy CT, which only provides information for x-ray linear attenuation coefficients, dual-energy CT is able to obtain both the electron density and effective atomic number for different materials in a quantitative way. In this study, as an alternative to dual-energy CT, a novel quantitative imaging method based on phase contrast CT is presented. Rather than requiring two projection data sets with different x-ray energy spectra, diffraction-grating-based phase contrast CT is capable of reconstructing images of both linear attenuation and refractive index decrement from the same projection data using a single x-ray energy spectra. From the two images, quantitative information of both the electron density and effective atomic number can be extracted. Two physical phantoms were constructed and used to validate the presented method. Experimental results demonstrate that (1) electron density can be accurately determined from refractive index decrement through a linear relationship, and (2) the effective atomic number can be explicitly derived from the ratio of the linear attenuation to refractive index decrement using a power function plus a constant. The presented method will provide insight into the technique of material separation and find its use in medical and industrial applications.

  14. Quantitative imaging of electron density and effective atomic number using phase contrast CT

    Science.gov (United States)

    Qi, Zhihua; Zambelli, Joseph; Bevins, Nicholas; Chen, Guang-Hong

    2010-05-01

    Compared to single energy CT, which only provides information for x-ray linear attenuation coefficients, dual-energy CT is able to obtain both the electron density and effective atomic number for different materials in a quantitative way. In this study, as an alternative to dual-energy CT, a novel quantitative imaging method based on phase contrast CT is presented. Rather than requiring two projection data sets with different x-ray energy spectra, diffraction-grating-based phase contrast CT is capable of reconstructing images of both linear attenuation and refractive index decrement from the same projection data using a single x-ray energy spectra. From the two images, quantitative information of both the electron density and effective atomic number can be extracted. Two physical phantoms were constructed and used to validate the presented method. Experimental results demonstrate that (1) electron density can be accurately determined from refractive index decrement through a linear relationship, and (2) the effective atomic number can be explicitly derived from the ratio of the linear attenuation to refractive index decrement using a power function plus a constant. The presented method will provide insight into the technique of material separation and find its use in medical and industrial applications.

  15. A novel quantitative imaging technique for material differentiation based on differential phase contrast CT

    Science.gov (United States)

    Qi, Zhihua; Zambelli, Joseph; Bevins, Nicholas; Chen, Guang-Hong

    2010-04-01

    Compared to single energy CT, which provides information only about the x-ray linear attenuation coefficients, dual energy CT is able to obtain the electron density and effective atomic number for different materials in a quantitative way. In this study, as an alternative to dual energy CT, a novel quantitative imaging method based on phase contrast CT is described. Rather than requiring two scans with different x-ray photon energies, diffraction grating-based phase contrast CT is capable of reconstructing images of both the linear attenuation and refractive index decrement from a single scan. From the two images, quantitative information of both the electron density and effective atomic number can be extracted. Experimental results demonstrate that: (1) electron density can be accurately determined from refractive index decrement through a linear relationship; and (2) effective atomic number can be explicitly derived from the ratio of linear attenuation to refractive index decrement, using a simple function, i.e., a power function plus a constant. The presented method will shed insight into the field of material separation and find its use in medical and non-medical applications.

  16. Image-Based Treatment Planning of the Post-Lumpectomy Breast Utilizing CT and 3TMRI

    Directory of Open Access Journals (Sweden)

    Geraldine Jacobson

    2011-01-01

    Full Text Available Accurate lumpectomy cavity definition is critical in breast treatment planning. We compared contouring lumpectomy cavity volume and cavity visualization score (CVS with CT versus 3T MRI. 29 patients were imaged with CT and 3T MRI. Seven additional boost planning sets were obtained for 36 image sets total. Three observers contoured the lumpectomy cavity on all images, assigning a cavity visualization score (CVS of 1 to 5. Measures of consistency and agreement for CT volumes were 98.84% and 98.62%, for T1 MRI were 95.65% and 95.55%, and for T2 MRI were 97.63% and 97.71%. The mean CT, T1 MRI, and T2 MRI CVS scores were 3.28, 3.38, and 4.32, respectively. There was a highly significant difference between CT and T2 scores (<.00001 and between T1 and T2 scores (<.00001. Interobserver consistency and agreement regarding volumes were high for all three modalities with T2 MRI CVS the highest. MRI may contribute to target definition in selected patients.

  17. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    2011-01-01

    in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...... is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small...

  18. A minimum spanning forest based classification method for dedicated breast CT images

    NARCIS (Netherlands)

    Pike, R.; Sechopoulos, I.; Fei, B.

    2015-01-01

    PURPOSE: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. METHODS: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bila

  19. Importance of PET/CT for imaging of colorectal cancer; Stellenwert der PET/CT zur Bildgebung des kolorektalen Karzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Meinel, F.G.; Schramm, N.; Graser, A.; Reiser, M.F.; Rist, C. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Haug, A.R. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2012-06-15

    Fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has emerged as a very useful imaging modality in the management of colorectal carcinoma. Data from the literature regarding the role of PET/CT in the initial diagnosis, staging, radiotherapy planning, response monitoring and surveillance of colorectal carcinoma is presented. Future directions and economic aspects are discussed. Computed tomography (CT), magnetic resonance imaging (MRI) and FDG-PET for colorectal cancer and endorectal ultrasound for rectal cancer. Combined FDG-PET/CT. While other imaging modalities allow superior visualization of the extent and invasion depth of the primary tumor, PET/CT is most sensitive for the detection of distant metastases of colorectal cancer. We recommend a targeted use of PET/CT in cases of unclear M staging, prior to metastasectomy and in suspected cases of residual or recurrent colorectal carcinoma with equivocal conventional imaging. The role of PET/CT in radiotherapy planning and response monitoring needs to be determined. Currently there is no evidence to support the routine use of PET/CT for colorectal screening, staging or surveillance. To optimally exploit the synergy between morphologic and functional information, FDG-PET should generally be performed as an integrated FDG-PET/CT with a contrast-enhanced CT component in colorectal carcinoma. (orig.) [German] Die Fluordesoxyglukose-Positronenemissionstomographie/Computertomographie (FDG-PET/CT) hat in den letzten Jahren zunehmende Bedeutung zur Bildgebung des kolorektalen Karzinoms erlangt. In diesem Beitrag stellen wir den Stand der Literatur zur Rolle der PET/CT bei Screening, Staging, Bestrahlungsplanung, Beurteilung eines Therapieansprechens und Nachsorge des kolorektalen Karzinoms dar. Zudem wird auf gesundheitsoekonomische Aspekte und zukuenftige Entwicklungen eingegangen. CT, MRT, FDG-PET, beim Rektumkarzinom zusaetzlich endorektaler Ultraschall. Kombinierte FDG-PET/CT. Waehrend

  20. Highly sensitive detection of the soft tissues based on refraction contrast by in-plane diffraction-enhanced imaging CT

    Science.gov (United States)

    Yuasa, Tetsuya; Hashimoto, Eiko; Maksimenko, Anton; Sugiyama, Hiroshi; Arai, Yoshinori; Shimao, Daisuke; Ichihara, Shu; Ando, Masami

    2008-07-01

    We discuss the recently proposed computed tomography (CT) technique based on refractive effects for biomedical use, which reconstructs the in-plane refractive-index gradient vector field in a cross-sectional plane of interest by detecting the angular deviation of the beam, refracted by a sample, from the incident beam, using the diffraction-enhanced imaging (DEI) method. The CT has advantages for delineating biological weakly absorbing soft tissues over the conventional absorption-contrast CT because of the use of phase sensitive detection. The paper aims to define the imaging scheme rigidly and to demonstrate its efficacy for non-destructive measurement of biomedical soft-tissue samples without imaging agent. We first describe the imaging principle of in-plane DEI-CT from the physico-mathematical viewpoints in detail, and investigate what physical quantities are extracted from the reconstructed images. Then, we introduce the imaging system using the synchrotron radiation as a light source, constructed at beamline BL-14B in KEK, Japan. Finally, we demonstrate the advantage of the refraction-based image for non-destructive analysis of biological sample by investigating the image of human breast cancer tumors obtained using the imaging system. Here, the refraction- and the apparent absorption-based images obtained simultaneously by the in-plane DEI-CT are compared. Also, the conventional absorption-based image obtained using micro-computed tomography (μCT) imaging system is compared with them. Thereby, it is shown that the refraction contrast much more sensitively delineates the soft tissues than the absorption contrast. In addition, the radiologic-histologic correlation study not only validates the efficacy for imaging soft tissues, but also produces the potential that the pathological inspection for the breast cancer tumors may be feasible non-destructively.

  1. Gallium-68 EDTA PET/CT for Renal Imaging.

    Science.gov (United States)

    Hofman, Michael S; Hicks, Rodney J

    2016-09-01

    Nuclear medicine renal imaging provides important functional data to assist in the diagnosis and management of patients with a variety of renal disorders. Physiologically stable metal chelates like ethylenediaminetetraacetic acid (EDTA) and diethylenetriamine penta-acetate (DTPA) are excreted by glomerular filtration and have been radiolabelled with a variety of isotopes for imaging glomerular filtration and quantitative assessment of glomerular filtration rate. Gallium-68 ((68)Ga) EDTA PET usage predates Technetium-99m ((99m)Tc) renal imaging, but virtually disappeared with the widespread adoption of gamma camera technology that was not optimal for imaging positron decay. There is now a reemergence of interest in (68)Ga owing to the greater availability of PET technology and use of (68)Ga to label other radiotracers. (68)Ga EDTA can be used a substitute for (99m)Tc DTPA for wide variety of clinical indications. A key advantage of PET for renal imaging over conventional scintigraphy is 3-dimensional dynamic imaging, which is particularly helpful in patients with complex anatomy in whom planar imaging may be nondiagnostic or difficult to interpret owing to overlying structures containing radioactive urine that cannot be differentiated. Other advantages include accurate and absolute (rather than relative) camera-based quantification, superior spatial and temporal resolution and integrated multislice CT providing anatomical correlation. Furthermore, the (68)Ga generator enables on-demand production at low cost, with no additional patient radiation exposure compared with conventional scintigraphy. Over the past decade, we have employed (68)Ga EDTA PET/CT primarily to answer difficult clinical questions in patients in whom other modalities have failed, particularly when it was envisaged that dynamic 3D imaging would be of assistance. We have also used it as a substitute for (99m)Tc DTPA if unavailable owing to supply issues, and have additionally examined the role of

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging ( ...

  8. A registration-based segmentation method with application to adiposity analysis of mice microCT images

    Science.gov (United States)

    Bai, Bing; Joshi, Anand; Brandhorst, Sebastian; Longo, Valter D.; Conti, Peter S.; Leahy, Richard M.

    2014-04-01

    Obesity is a global health problem, particularly in the U.S. where one third of adults are obese. A reliable and accurate method of quantifying obesity is necessary. Visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) are two measures of obesity that reflect different associated health risks, but accurate measurements in humans or rodent models are difficult. In this paper we present an automatic, registration-based segmentation method for mouse adiposity studies using microCT images. We co-register the subject CT image and a mouse CT atlas. Our method is based on surface matching of the microCT image and an atlas. Surface-based elastic volume warping is used to match the internal anatomy. We acquired a whole body scan of a C57BL6/J mouse injected with contrast agent using microCT and created a whole body mouse atlas by manually delineate the boundaries of the mouse and major organs. For method verification we scanned a C57BL6/J mouse from the base of the skull to the distal tibia. We registered the obtained mouse CT image to our atlas. Preliminary results show that we can warp the atlas image to match the posture and shape of the subject CT image, which has significant differences from the atlas. We plan to use this software tool in longitudinal obesity studies using mouse models.

  9. Segmentation of the ovine lung in 3D CT Images

    Science.gov (United States)

    Shi, Lijun; Hoffman, Eric A.; Reinhardt, Joseph M.

    2004-04-01

    Pulmonary CT images can provide detailed information about the regional structure and function of the respiratory system. Prior to any of these analyses, however, the lungs must be identified in the CT data sets. A popular animal model for understanding lung physiology and pathophysiology is the sheep. In this paper we describe a lung segmentation algorithm for CT images of sheep. The algorithm has two main steps. The first step is lung extraction, which identifies the lung region using a technique based on optimal thresholding and connected components analysis. The second step is lung separation, which separates the left lung from the right lung by identifying the central fissure using an anatomy-based method incorporating dynamic programming and a line filter algorithm. The lung segmentation algorithm has been validated by comparing our automatic method to manual analysis for five pulmonary CT datasets. The RMS error between the computer-defined and manually-traced boundary is 0.96 mm. The segmentation requires approximately 10 minutes for a 512x512x400 dataset on a PC workstation (2.40 GHZ CPU, 2.0 GB RAM), while it takes human observer approximately two hours to accomplish the same task.

  10. Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

    Science.gov (United States)

    Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W

    2015-07-01

    CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.

  11. Three modality image registration of brain SPECT/CT and MR images for quantitative analysis of dopamine transporter imaging

    Science.gov (United States)

    Yamaguchi, Yuzuho; Takeda, Yuta; Hara, Takeshi; Zhou, Xiangrong; Matsusako, Masaki; Tanaka, Yuki; Hosoya, Kazuhiko; Nihei, Tsutomu; Katafuchi, Tetsuro; Fujita, Hiroshi

    2016-03-01

    Important features in Parkinson's disease (PD) are degenerations and losses of dopamine neurons in corpus striatum. 123I-FP-CIT can visualize activities of the dopamine neurons. The activity radio of background to corpus striatum is used for diagnosis of PD and Dementia with Lewy Bodies (DLB). The specific activity can be observed in the corpus striatum on SPECT images, but the location and the shape of the corpus striatum on SPECT images only are often lost because of the low uptake. In contrast, MR images can visualize the locations of the corpus striatum. The purpose of this study was to realize a quantitative image analysis for the SPECT images by using image registration technique with brain MR images that can determine the region of corpus striatum. In this study, the image fusion technique was used to fuse SPECT and MR images by intervening CT image taken by SPECT/CT. The mutual information (MI) for image registration between CT and MR images was used for the registration. Six SPECT/CT and four MR scans of phantom materials are taken by changing the direction. As the results of the image registrations, 16 of 24 combinations were registered within 1.3mm. By applying the approach to 32 clinical SPECT/CT and MR cases, all of the cases were registered within 0.86mm. In conclusions, our registration method has a potential in superimposing MR images on SPECT images.

  12. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    Science.gov (United States)

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  13. SU-D-BRB-01: 4D-CT Lung Ventilation Images Vary with 4D-CT Sorting Techniques.

    Science.gov (United States)

    Yamamoto, T; Kabus, S; Lorenz, C; Johnston, E; Maxim, P; Loo, B; Keall, P

    2012-06-01

    4D-CT ventilation imaging is a novel promising technique for lung functional imaging and has potential as a biomarker for radiation pneumonitis, but has not been validated in human subjects. The current 4D- CT technique with phase-based sorting results in artifacts at an alarmingly high frequency (90%), which may introduce variations into ventilation calculations. The purpose of this study was to quantify the variability of 4D- CT ventilation imaging to 4D-CT sorting techniques. Two 4D-CT images were generated from the same data set by: (1) phase-based; (2) anatomic similarity- and abdominal displacement-based sorting for five patients. Two ventilation image sets (V_phase and V_anat) were then calculated by deformable image registration of peak-exhale and peak-inhale4D-CT images and quantification of regional volume change based on Hounsfield unit change. The variability of 4D-CT ventilation imaging wasquantified using the voxel-based Spearman rank correlation coefficients and Dice similarity coefficients (DSC) for the spatial overlap of segmented low- functional lung regions. The relationship between the abdominal motionrange variation and ventilation variation was also assessed using linearregression. Furthermore, the correlations between V_phase or V_anat and SPECT ventilation images (assumed ground-truth) were compared. In general, displacement- and anatomic similarity-based sorting reduced 4D- CT artifacts compared to phase-based sorting. The voxel-based correlationsbetween V_phase and V_anat were only moderate (range, 0.57-0.77). The DSCs for the low-functional lung regions were moderate to substantial (0.58-0.70). The relationship between the motion range variation and ventilation variation was strong on average (R2=0.79±0.25), suggesting that ventilation variations are related to 4D-CT artifacts. Vanat was found to improve correlations with SPECT ventilation images compared to V_phase. 4D-CT ventilation images vary markedly with 4D-CT sorting techniques. 4

  14. A study on using texture analysis methods for identifying lobar fissure regions in isotropic CT images.

    Science.gov (United States)

    Wei, Q; Hu, Y

    2009-01-01

    The major hurdle for segmenting lung lobes in computed tomographic (CT) images is to identify fissure regions, which encase lobar fissures. Accurate identification of these regions is difficult due to the variable shape and appearance of the fissures, along with the low contrast and high noise associated with CT images. This paper studies the effectiveness of two texture analysis methods - the gray level co-occurrence matrix (GLCM) and the gray level run length matrix (GLRLM) - in identifying fissure regions from isotropic CT image stacks. To classify GLCM and GLRLM texture features, we applied a feed-forward back-propagation neural network and achieved the best classification accuracy utilizing 16 quantized levels for computing the GLCM and GLRLM texture features and 64 neurons in the input/hidden layers of the neural network. Tested on isotropic CT image stacks of 24 patients with the pathologic lungs, we obtained accuracies of 86% and 87% for identifying fissure regions using the GLCM and GLRLM methods, respectively. These accuracies compare favorably with surgeons/radiologists' accuracy of 80% for identifying fissure regions in clinical settings. This shows promising potential for segmenting lung lobes using the GLCM and GLRLM methods.

  15. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  16. Varying-energy CT imaging method based on EM-TV

    Science.gov (United States)

    Chen, Ping; Han, Yan

    2016-11-01

    For complicated structural components with wide x-ray attenuation ranges, conventional fixed-energy computed tomography (CT) imaging cannot obtain all the structural information. This limitation results in a shortage of CT information because the effective thickness of the components along the direction of x-ray penetration exceeds the limit of the dynamic range of the x-ray imaging system. To address this problem, a varying-energy x-ray CT imaging method is proposed. In this new method, the tube voltage is adjusted several times with the fixed lesser interval. Next, the fusion of grey consistency and logarithm demodulation are applied to obtain full and lower noise projection with a high dynamic range (HDR). In addition, for the noise suppression problem of the analytical method, EM-TV (expectation maximization-total Jvariation) iteration reconstruction is used. In the process of iteration, the reconstruction result obtained at one x-ray energy is used as the initial condition of the next iteration. An accompanying experiment demonstrates that this EM-TV reconstruction can also extend the dynamic range of x-ray imaging systems and provide a higher reconstruction quality relative to the fusion reconstruction method.

  17. TRANSFORMATION ALGORITHM FOR IMAGES OBTAINED BY OMNIDIRECTIONAL CAMERAS

    Directory of Open Access Journals (Sweden)

    V. P. Lazarenko

    2015-01-01

    Full Text Available Omnidirectional optoelectronic systems find their application in areas where a wide viewing angle is critical. However, omnidirectional optoelectronic systems have a large distortion that makes their application more difficult. The paper compares the projection functions of traditional perspective lenses and omnidirectional wide angle fish-eye lenses with a viewing angle not less than 180°. This comparison proves that distortion models of omnidirectional cameras cannot be described as a deviation from the classic model of pinhole camera. To solve this problem, an algorithm for transforming omnidirectional images has been developed. The paper provides a brief comparison of the four calibration methods available in open source toolkits for omnidirectional optoelectronic systems. Geometrical projection model is given used for calibration of omnidirectional optical system. The algorithm consists of three basic steps. At the first step, we calculate he field of view of a virtual pinhole PTZ camera. This field of view is characterized by an array of 3D points in the object space. At the second step the array of corresponding pixels for these three-dimensional points is calculated. Then we make a calculation of the projection function that expresses the relation between a given 3D point in the object space and a corresponding pixel point. In this paper we use calibration procedure providing the projection function for calibrated instance of the camera. At the last step final image is formed pixel-by-pixel from the original omnidirectional image using calculated array of 3D points and projection function. The developed algorithm gives the possibility for obtaining an image for a part of the field of view of an omnidirectional optoelectronic system with the corrected distortion from the original omnidirectional image. The algorithm is designed for operation with the omnidirectional optoelectronic systems with both catadioptric and fish-eye lenses

  18. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging.

    Science.gov (United States)

    Kaufmann, Sascha; Sauter, Alexander; Spira, Daniel; Gatidis, Sergios; Ketelsen, Dominik; Heuschmid, Martin; Claussen, Claus D; Thomas, Christoph

    2013-05-01

    To measure and compare the objective image quality of true noncontrast (TNC) images with virtual noncontrast (VNC) images acquired by tin-filter-enhanced, dual-source, dual-energy computed tomography (DECT) of upper abdomen. Sixty-three patients received unenhanced abdominal CT and enhanced abdominal DECT (100/140 kV with tin filter) in portal-venous phase. VNC images were calculated from the DECT datasets using commercially available software. The mean attenuation of relevant tissues and image quality were compared between the TNC and VNC images. Image quality was rated objectively by measuring image noise and the sharpness of object edges using custom-designed software. Measurements were compared using Student two-tailed t-test. Correlation coefficients for tissue attenuation measurements between TNC and VNC were calculated and the relative deviations were illustrated using Bland-Altman plots. Mean attenuation differences between TNC and VNC (HUTNC - HUVNC) image sets were as follows: right liver lobe -4.94 Hounsfield units (HU), left liver lobe -3.29 HU, vena cava -2.19 HU, spleen -7.46 HU, pancreas 1.29 HU, fat -11.14 HU, aorta 1.29 HU, bone marrow 36.83 HU (all P Mean image noise was significantly higher in TNC images (P images (P = .19). The Hounsfield units in VNC images closely resemble TNC images in the majority of the organs of the upper abdomen (kidneys, liver, pancreas). In spleen and fat, Hounsfield numbers in VNC images are tend to be higher than in TNC images. VNC images show a low image noise and satisfactory edge sharpness. Other criteria of image quality and the depiction of certain lesions need to be evaluated additionally. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  19. Imaging of cochlear implant electrode array with flat-detector CT and conventional multislice CT: comparison of image quality and radiation dose.

    Science.gov (United States)

    Struffert, Tobias; Hertel, Victoria; Kyriakou, Yannis; Krause, Jens; Engelhorn, Tobias; Schick, Bernhard; Iro, Heinrich; Hornung, Joachim; Doerfler, Arnd

    2010-04-01

    Cochlear implantation assessment is possible using commercially available standard flat-detector computed tomography (FD-CT) protocols. Image quality is superior to multislice CT (MSCT). The radiation dose of FD-CT is lower in comparison with MSCT standard protocols and may therefore overcome the limitations of MSCT in the evaluation of cochlear implants. FD-CT offers higher spatial resolution than MSCT. Our objective was to compare the image quality of FD-CT to conventional MSCT in the visualization of a cochlear implant electrode array with respect to radiation exposure. An isolated temporal bone specimen was scanned using a commercially available FD-CT system and a 4 and 64 row MSCT scanner. Different scanning protocols were used. Image quality was assessed by four independent readers using a scoring system with different criteria describing delineation of the cochlea and the electrode array, image noise and spatial resolution. Radiation dose was measured using the CT dose index (CTDI) and a 16 cm acrylic phantom. Image quality was rated superior for FD-CT for all criteria by all readers. Single electrode contacts were only visible in FD-CT and assessment of implant position was improved by FD-CT. The radiation dose of FD-CT was half that of MSCT standard protocols.

  20. Optical-CT imaging of complex 3D dose distributions

    Science.gov (United States)

    Oldham, Mark; Kim, Leonard; Hugo, Geoffrey

    2005-04-01

    The limitations of conventional dosimeters restrict the comprehensiveness of verification that can be performed for advanced radiation treatments presenting an immediate and substantial problem for clinics attempting to implement these techniques. In essence, the rapid advances in the technology of radiation delivery have not been paralleled by corresponding advances in the ability to verify these treatments. Optical-CT gel-dosimetry is a relatively new technique with potential to address this imbalance by providing high resolution 3D dose maps in polymer and radiochromic gel dosimeters. We have constructed a 1st generation optical-CT scanner capable of high resolution 3D dosimetry and applied it to a number of simple and increasingly complex dose distributions including intensity-modulated-radiation-therapy (IMRT). Prior to application to IMRT, the robustness of optical-CT gel dosimetry was investigated on geometry and variable attenuation phantoms. Physical techniques and image processing methods were developed to minimize deleterious effects of refraction, reflection, and scattered laser light. Here we present results of investigations into achieving accurate high-resolution 3D dosimetry with optical-CT, and show clinical examples of 3D IMRT dosimetry verification. In conclusion, optical-CT gel dosimetry can provide high resolution 3D dose maps that greatly facilitate comprehensive verification of complex 3D radiation treatments. Good agreement was observed at high dose levels (>50%) between planned and measured dose distributions. Some systematic discrepancies were observed however (rms discrepancy 3% at high dose levels) indicating further work is required to eliminate confounding factors presently compromising the accuracy of optical-CT 3D gel-dosimetry.

  1. Quantitative imaging of excised osteoarthritic cartilage using spectral CT

    Energy Technology Data Exchange (ETDEWEB)

    Rajendran, Kishore; Bateman, Christopher J.; Younis, Raja Aamir; De Ruiter, Niels J.A.; Ramyar, Mohsen; Anderson, Nigel G. [University of Otago - Christchurch, Department of Radiology, Christchurch (New Zealand); Loebker, Caroline [University of Otago, Christchurch Regenerative Medicine and Tissue Engineering Group, Department of Orthopaedic Surgery and Musculoskeletal Medicine, Christchurch (New Zealand); University of Twente, Department of Developmental BioEngineering, Enschede (Netherlands); Schon, Benjamin S.; Hooper, Gary J.; Woodfield, Tim B.F. [University of Otago, Christchurch Regenerative Medicine and Tissue Engineering Group, Department of Orthopaedic Surgery and Musculoskeletal Medicine, Christchurch (New Zealand); Chernoglazov, Alex I. [University of Canterbury, Human Interface Technology Laboratory New Zealand, Christchurch (New Zealand); Butler, Anthony P.H. [University of Otago - Christchurch, Department of Radiology, Christchurch (New Zealand); European Organisation for Nuclear Research (CERN), Geneva (Switzerland); MARS Bioimaging, Christchurch (New Zealand)

    2017-01-15

    To quantify iodine uptake in articular cartilage as a marker of glycosaminoglycan (GAG) content using multi-energy spectral CT. We incubated a 25-mm strip of excised osteoarthritic human tibial plateau in 50 % ionic iodine contrast and imaged it using a small-animal spectral scanner with a cadmium telluride photon-processing detector to quantify the iodine through the thickness of the articular cartilage. We imaged both spectroscopic phantoms and osteoarthritic tibial plateau samples. The iodine distribution as an inverse marker of GAG content was presented in the form of 2D and 3D images after applying a basis material decomposition technique to separate iodine in cartilage from bone. We compared this result with a histological section stained for GAG. The iodine in cartilage could be distinguished from subchondral bone and quantified using multi-energy CT. The articular cartilage showed variation in iodine concentration throughout its thickness which appeared to be inversely related to GAG distribution observed in histological sections. Multi-energy CT can quantify ionic iodine contrast (as a marker of GAG content) within articular cartilage and distinguish it from bone by exploiting the energy-specific attenuation profiles of the associated materials. (orig.)

  2. Kinematic CT and MR imaging of the patellofemoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C.; Brossmann, J.; Heller, M. [Klinik fuer Radiologische Diagnostik, Christian-Albrechts-Universitaet, Kiel (Germany)

    1999-04-01

    Anterior knee pain is a frequently encountered orthopedic symptom and is often associated with patellofemoral malalignment, which may cause chondromalacia of the patella. The difficulty in determining the patellar position between 0 and 30 of knee flexion with a conventional axial radiographic examination is well known. The introduction of computed tomography (CT) and magnetic resonance (MR) imaging for the diagnosis of knee joint abnormalities has enabled assessment of the patellar position in this critical range. More recently, emphasis has been placed on dynamic visualization of patellar motion to detect an abnormal tracking pattern. The important influence of the quadriceps muscle on the patellar tracking pattern is well known and has been examined during active knee extension by the use of ultrafast CT, and motion-triggered and ultrafast MR imaging. This article provides an overview of the current status of kinematic CT and MR imaging in the diagnosis of patellofemoral alignment, its clinical implications, and future directions. (orig.) With 13 figs., 5 tabs., 47 refs.

  3. Semiautomatic segmentation of liver metastases on volumetric CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Jiayong [Department of Biomedical Engineering, Shanghai University of Medicine & Health Sciences, 101 Yingkou Road, Yang Pu District, Shanghai 200093 (China); Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@cumc.columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-11-15

    Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation

  4. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Liao, S; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

  5. CT and MR imaging of odontoid abnormalities: A pictorial review

    Directory of Open Access Journals (Sweden)

    Nishchint Jain

    2016-01-01

    Full Text Available Odontoid process is the central pillar of the craniovertebral junction. Imaging of this small structure continues to be a challenge for the radiologists due to complex bony and ligamentous anatomy. A wide range of developmental and acquired abnormalities of odontoid have been identified. Their accurate radiologic evaluation is important as different lesions have markedly different clinical course, patient management, and prognosis. This article seeks to provide knowledge for interpreting appearances of odontoid on computed tomography (CT and magnetic resonance imaging (MRI with respect to various disease processes, along with providing a quick review of the embryology and relevant anatomy.

  6. Pancreas tumor model in rabbit imaged by perfusion CT scans

    Science.gov (United States)

    Gunn, Jason; Tichauer, Kenneth; Moodie, Karen; Kane, Susan; Hoopes, Jack; Stewart, Errol E.; Hadway, Jennifer; Lee, Ting-Yim; Pereira, Stephen P.; Pogue, Brian W.

    2013-03-01

    The goal of this work was to develop and validate a pancreas tumor animal model to investigate the relationship between photodynamic therapy (PDT) effectiveness and photosensitizer drug delivery. More specifically, this work lays the foundation for investigating the utility of dynamic contrast enhanced blood perfusion imaging to be used to inform subsequent PDT. A VX2 carcinoma rabbit cell line was grown in the tail of the pancreas of three New Zealand White rabbits and approximately 3-4 weeks after implantation the rabbits were imaged on a CT scanner using a contrast enhanced perfusion protocol, providing parametric maps of blood flow, blood volume, mean transit time, and vascular permeability surface area product.

  7. CT and MR Image Fusion Scheme in Nonsubsampled Contourlet Transform Domain

    OpenAIRE

    Ganasala, Padma; Kumar, Vinod

    2014-01-01

    Fusion of CT and MR images allows simultaneous visualization of details of bony anatomy provided by CT image and details of soft tissue anatomy provided by MR image. This helps the radiologist for the precise diagnosis of disease and for more effective interventional treatment procedures. This paper aims at designing an effective CT and MR image fusion method. In the proposed method, first source images are decomposed by using nonsubsampled contourlet transform (NSCT) which is a shift-invaria...

  8. X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT

    Directory of Open Access Journals (Sweden)

    Sorapong Aootaphao

    2016-01-01

    Full Text Available Soft tissue images from portable cone beam computed tomography (CBCT scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work, we propose the X-ray scatter correction method for improving soft tissue images. The X-ray scatter correction scheme to estimate X-ray scatter signals is based on the deconvolution technique using the maximum likelihood estimation maximization (MLEM method. The scatter kernels are obtained by simulating the PMMA sheet on the Monte Carlo simulation (MCS software. In the experiment, we used the QRM phantom to quantitatively compare with fan-beam CT (FBCT data in terms of CT number values, contrast to noise ratio, cupping artifacts, and low contrast detectability. Moreover, the PH3 angiography phantom was also used to mimic human soft tissues in the brain. The reconstructed images with our proposed scatter correction show significant improvement on image quality. Thus the proposed scatter correction technique has high potential to detect soft tissues in the brain.

  9. A curvelet transform approach for the fusion of MR and CT images

    Science.gov (United States)

    Ali, F. E.; El-Dokany, I. M.; Saad, A. A.; Abd El-Samie, F. E.

    2010-02-01

    There are several medical imaging techniques such as the magnetic resonance (MR) and the computed tomography (CT) techniques. Both techniques give sophisticated characteristics of the region to be imaged. This paper proposes a curvelet based approach for fusing MR and CT images to obtain images with as much detail as possible, for the sake of medical diagnosis. This approach is based on the application of the additive wavelet transform (AWT) on both images and the segmentation of their detail planes into small overlapping tiles. The ridgelet transform is then applied on each of these tiles, and the fusion process is performed on the ridgelet transforms of the tiles. Simulation results show the superiority of the proposed curvelet fusion approach to the traditional fusion techniques like the multiresolution discrete wavelet transform (DWT) technique and the principal component analysis (PCA) technique. The fusion of MR and CT images in the presence of noise is also studied and the results reveal that unlike the DWT fusion technique, the proposed curvelet fusion approach doesn't require denoising.

  10. Computer-aided diagnosis for osteoporosis using chest 3D CT images

    Science.gov (United States)

    Yoneda, K.; Matsuhiro, M.; Suzuki, H.; Kawata, Y.; Niki, N.; Nakano, Y.; Ohmatsu, H.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.

    2016-03-01

    The patients of osteoporosis comprised of about 13 million people in Japan and it is one of the problems the aging society has. In order to prevent the osteoporosis, it is necessary to do early detection and treatment. Multi-slice CT technology has been improving the three dimensional (3-D) image analysis with higher body axis resolution and shorter scan time. The 3-D image analysis using multi-slice CT images of thoracic vertebra can be used as a support to diagnose osteoporosis and at the same time can be used for lung cancer diagnosis which may lead to early detection. We develop automatic extraction and partitioning algorithm for spinal column by analyzing vertebral body structure, and the analysis algorithm of the vertebral body using shape analysis and a bone density measurement for the diagnosis of osteoporosis. Osteoporosis diagnosis support system obtained high extraction rate of the thoracic vertebral in both normal and low doses.

  11. MR imaging compared with CT, angiography, and myelography supplemented with CT in the diagnosis of spinal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro; Uchino, Akira; Matsumoto, Shunichi; Fujii, Kiyotaka; Fukui, Masashi; Masuda, Kouji (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    To clarify the significance of MR imaging and the present status of CT, angiography, and myelography supplemented by CT (M-CTM), the radiological findings of 50 spinal tumors were reviewed and analyzed. MR imaging was most effective for visualizing morphological features such as the margins and/or inner structures of the tumors. CT was also effective for imaging 'dumbbell' neurinomas and extradural tumors. Angiography was necessary in one hemangioblastoma and in cervical extradural tumors. M-CTM visualized the morphology of intradural extramedullary tumors and extradural tumors, but provided no new information in most of these cases. It was concluded that when using MR the indications for CT, angiography, and M-CTM are limited and that CT or angiography should be performed only in selected cases. M-CTM appeared to be unnecessary. (author).

  12. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Ronald; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Delgado-Bolton, Roberto [University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), Logrono, La Rioja (Spain); Oyen, Wim J.G.; Visser, Eric [Radboud University Nijmegen Medical Centre, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Giammarile, Francesco [Centre Hospitalier Universitaire de Lyon, Department of Nuclear Medicine, Lyon (France); Tatsch, Klaus [Municipal Hospital Karlsruhe Inc., Department of Nuclear Medicine, Karlsruhe (Germany); Eschner, Wolfgang [University of Cologne, Department of Nuclear Medicine, Cologne (Germany); Verzijlbergen, Fred J. [Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands); Barrington, Sally F.; Pike, Lucy C. [King' s College London, King' s Health Partners, PET Imaging Centre, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Weber, Wolfgang A. [Memorial Sloan Kettering Center, Department of Radiology, New York, NY (United States); Stroobants, Sigrid [Antwerp University Hospital, Department of Nuclear Medicine, Antwerp (Belgium); Delbeke, Dominique [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Donohoe, Kevin J. [Beth Israel Deaconess Medical Center, Boston, MA (United States); Holbrook, Scott [Invivo Molecular Imaging LLC, Gray, TN (United States); Graham, Michael M. [University of Iowa, Department of Radiology, Iowa City, IA (United States); Testanera, Giorgio; Chiti, Arturo [Humanitas Clinical and Research Center, Department of Nuclear Medicine, Rozzano, MI (Italy); Zijlstra, Josee [VU University Medical Centre, Department of Hematology, Amsterdam (Netherlands); Hoekstra, Corneline J. [Jeroen Bosch Hospital, Department of Nuclear Medicine, Den Bosch (Netherlands); Pruim, Jan; Willemsen, Antoon [University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Arends, Bertjan [Catharina Hospital, Department of Clinical Physics, Eindhoven (Netherlands); Kotzerke, Joerg [University Hospital Dresden, Clinic and Outpatient Clinic for Nuclear Medicine, Dresden (Germany); Bockisch, Andreas [University Hospital Essen, Clinic for Nuclear Medicine, Essen (Germany); Beyer, Thomas [Medical University of Vienna, Centre for Medical Physics and Biomedical Engineering, Vienna (Austria); Krause, Bernd J. [University Hospital Rostock, Department of Nuclear Medicine, Rostock (Germany)

    2014-12-02

    The purpose of these guidelines is to assist physicians in recommending, performing, interpreting and reporting the results of FDG PET/CT for oncological imaging of adult patients. PET is a quantitative imaging technique and therefore requires a common quality control (QC)/quality assurance (QA) procedure to maintain the accuracy and precision of quantitation. Repeatability and reproducibility are two essential requirements for any quantitative measurement and/or imaging biomarker. Repeatability relates to the uncertainty in obtaining the same result in the same patient when he or she is examined more than once on the same system. However, imaging biomarkers should also have adequate reproducibility, i.e. the ability to yield the same result in the same patient when that patient is examined on different systems and at different imaging sites. Adequate repeatability and reproducibility are essential for the clinical management of patients and the use of FDG PET/CT within multicentre trials. A common standardised imaging procedure will help promote the appropriate use of FDG PET/CT imaging and increase the value of publications and, therefore, their contribution to evidence-based medicine. Moreover, consistency in numerical values between platforms and institutes that acquire the data will potentially enhance the role of semiquantitative and quantitative image interpretation. Precision and accuracy are additionally important as FDG PET/CT is used to evaluate tumour response as well as for diagnosis, prognosis and staging. Therefore both the previous and these new guidelines specifically aim to achieve standardised uptake value harmonisation in multicentre settings. (orig.)

  13. Elastic registration of multiphase CT images of liver

    Science.gov (United States)

    Heldmann, Stefan; Zidowitz, Stephan

    2009-02-01

    In this work we present a novel approach for elastic image registration of multi-phase contrast enhanced CT images of liver. A problem in registration of multiphase CT is that the images contain similar but complementary structures. In our application each image shows a different part of the vessel system, e.g., portal/hepatic venous/arterial, or biliary vessels. Portal, arterial and biliary vessels run in parallel and abut on each other forming the so called portal triad, while hepatic veins run independent. Naive registration will tend to align complementary vessel. Our new approach is based on minimizing a cost function consisting of a distance measure and a regularizer. For the distance we use the recently proposed normalized gradient field measure that focuses on the alignment of edges. For the regularizer we use the linear elastic potential. The key feature of our approach is an additional penalty term using segmentations of the different vessel systems in the images to avoid overlaps of complementary structures. We successfully demonstrate our new method by real data examples.

  14. Coronary imaging techniques with emphasis on CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lederlin, Mathieu; Latrabe, Valerie; Corneloup, Olivier; Cochet, Hubert; Montaudon, Michel; Laurent, Francois [Hopital Cardiologique, CHU Bordeaux, Thoracic and Cardiovascular Imaging Department, Pessac (France); Thambo, Jean-Benoit [Hopital Cardiologique, CHU Bordeaux, Pediatric and Adult Congenital Heart Disease Unit, Pessac (France)

    2011-12-15

    Coronary artery imaging in children is challenging, with high demands both on temporal and spatial resolution due to high heart rates and smaller anatomy. Although invasive conventional coronary angiography remains the benchmark technique, over the past 10 years, CT and MRI have emerged in the field of coronary imaging. The choice of hardware is important. For CT, the minimum requirement is a 64-channel scanner. The temporal resolution of the scanner is most important for optimising image quality and minimising radiation dose. Manufacturers have developed several modes of electrocardiographic (ECG) triggering to facilitate dose reduction. Recent technical advances have opened new possibilities in MRI coronary imaging. As a non-ionising radiation technique, MRI is of great interest in paediatric imaging. It is currently recommended in centres with appropriate expertise for the screening of patients with suspected congenital coronary anomalies. However, MRI is still not feasible in infants. This review describes and discusses the technical requirements and the pros and cons of all three techniques. (orig.)

  15. Image quality in CT: From physical measurements to model observers.

    Science.gov (United States)

    Verdun, F R; Racine, D; Ott, J G; Tapiovaara, M J; Toroi, P; Bochud, F O; Veldkamp, W J H; Schegerer, A; Bouwman, R W; Giron, I Hernandez; Marshall, N W; Edyvean, S

    2015-12-01

    Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.

  16. CT imaging with fistulography for perianal fistula: does it really help the surgeon?

    Science.gov (United States)

    Liang, Changhu; Jiang, Wanli; Zhao, Bin; Zhang, Yan; Du, Yinglin; Lu, Yongchao

    2013-01-01

    To prospectively evaluate the relative accuracy of computed tomography (CT) fistulography for preoperative assessment of fistula in ano. Ethical committee approval and informed consent were obtained. A total of 22 patients (15 male and 7 female, age 21-58 years) who were suspected of having fistula in ano underwent preoperative CT fistulography (CTF). The CT images of 0.6 mm were obtained respectively before and after fistulography; contrast-enhanced CT scan was also performed in 22 patients. CTF images were evaluated by two expert radiologists to assess the fistulas in the following respects: (a) the volume-rendered imaging; (b) the extensions of active inflammatory tissue; (c) the internal opening and external opening; (d) the hidden areas of tract or abscess; and (e) the deep abscess adjacent to fistula. CT findings in 18 patients were compared with surgical findings or exam under anesthesia. The CTF findings in 18 cases were basically in accordance with the surgical findings and/or examination findings under anesthesia. Both coronal and transverse planes were useful in assessing the location and direction of tracts or abscesses. Complicated spatial information within the perianal soft tissue about the fistula with secondary ramifications or abscesses can be easily demonstrated to the surgeons. Contrast-enhanced images were useful in assessing the inflammatory lesion activity and infiltrated area. CTF exquisitely depicts the perianal anatomy and shows the fistulous tracks with their associated ramifications, enables selection of the most appropriate surgical treatment, and therefore minimizes all chances of recurrence. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Fundamentals of PET and PET/CT imaging.

    Science.gov (United States)

    Basu, Sandip; Kwee, Thomas C; Surti, Suleman; Akin, Esma A; Yoo, Don; Alavi, Abass

    2011-06-01

    In this review, the fundamental principles of fluorodeoxyglucose (FDG) positron emission tomography (PET) and FDG PET/computed tomography (CT) imaging have been described. The basic physics of PET instrumentation, radiotracer chemistry, and the artifacts, as well as normal physiological or benign pathological variants, have been described and presented to the readers in a lucid manner to enable them an easy grasp of the fundamentals of the subject. Finally, we have outlined the current developments in quantitative PET imaging, including dual time point and delayed PET imaging, time-of-flight technology in PET imaging and partial volume correction, and global disease assessment with their potential of being incorporated into the assessment of benign and malignant disorders.

  18. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  19. Dynamic CT perfusion image data compression for efficient parallel processing.

    Science.gov (United States)

    Barros, Renan Sales; Olabarriaga, Silvia Delgado; Borst, Jordi; van Walderveen, Marianne A A; Posthuma, Jorrit S; Streekstra, Geert J; van Herk, Marcel; Majoie, Charles B L M; Marquering, Henk A

    2016-03-01

    The increasing size of medical imaging data, in particular time series such as CT perfusion (CTP), requires new and fast approaches to deliver timely results for acute care. Cloud architectures based on graphics processing units (GPUs) can provide the processing capacity required for delivering fast results. However, the size of CTP datasets makes transfers to cloud infrastructures time-consuming and therefore not suitable in acute situations. To reduce this transfer time, this work proposes a fast and lossless compression algorithm for CTP data. The algorithm exploits redundancies in the temporal dimension and keeps random read-only access to the image elements directly from the compressed data on the GPU. To the best of our knowledge, this is the first work to present a GPU-ready method for medical image compression with random access to the image elements from the compressed data.

  20. Imaging performance in differential phase contrast CT compared with the conventional CT-noise equivalent quanta NEQ(k)

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2012-03-01

    The grating-based x-ray differential phase contrast (DPC) CT is emerging as a new technology with the potential for extensive preclinical and clinical applications. In general, the performance of an imaging system is jointly determined by its signal property (modulation transfer function-MTF(k)) and noise property (noise power spectrum-NPS(k)), which is characterized by its spectrum of noise equivalent quanta. As reported by us previously, owing to an adoption of the Hilbert filtering for image reconstruction in the fashion of filtered backprojection (FBP), the noise property of DPC-CT characterized by its NPS(k) differs drastically from that of the conventional attenuation-based CT (1/|k| trait vs. |k| trait). In this work, via system analysis, modeling and simulated phantom study, we initially investigate the signal property of DPC-CT characterized by its MTF(k) and compare it with that of the conventional CT. In addition, we investigate the DPC-CT's spectrum of noise equivalent quanta NEQ(k) - the most important figure of merit (FOM) in the assessment of an imaging system's performance - by taking the MTF(k) and NPS(k) jointly into account. Through such a thorough investigation into both the signal and noise properties, the imaging performance of DPC-CT and its potential over the conventional attenuation-based CT can be fully understood and appreciated.

  1. Comparison of {sup 131}I whole-body imaging, {sup 131}I SPECT/CT, and {sup 18}F-FDG PET/CT in the detection of metastatic thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong-Ryool; Chong, Ari; Kim, Jahae; Kang, Sae-Ryung; Song, Ho-Chun; Bom, Hee-Seung [Chonnam National University Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Gwangju (Korea, Republic of); Byun, Byung-Hyun; Hong, Sun-Pyo; Yoo, Su-Woong [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Hwasun, Jeonnam (Korea, Republic of); Kim, Dong-Yeon [Dongguk University, Department of Chemistry, Seoul (Korea, Republic of); Chonnam National University Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Gwangju (Korea, Republic of); Min, Jung-Joon [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Hwasun, Jeonnam (Korea, Republic of); Center for Biomedical Human Resources at Chonnam National University, Brain Korea 21 Project, Gwangju (Korea, Republic of)

    2011-08-15

    The aim of this study was to compare {sup 131}I whole-body scintigraphy (WBS), WBS with {sup 131}I single photon emission computed tomography/computed tomography (SPECT/CT), and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the detection of distant metastases of differentiated thyroid cancer (DTC). A total of 140 patients with 258 foci of suspected distant metastases were evaluated. {sup 131}I WBS, {sup 131}I SPECT/CT, and {sup 18}F-FDG PET/CT images were interpreted separately. The final diagnosis was obtained from histopathologic study, serum thyroglobulin level, other imaging modalities, and/or clinical follow-up. Of the 140 patients with 258 foci, 46 patients with 166 foci were diagnosed as positive for distant metastasis. The sensitivity, specificity, and diagnostic accuracy of each imaging modality were 65, 55, and 59%, respectively, for {sup 131}I WBS; 65, 95, and 85% for {sup 131}I SPECT/CT, respectively; and 61, 98, and 86%, respectively, for {sup 18}F-FDG PET/CT in patient-based analyses. Lesion-based analyses demonstrated that both SPECT/CT and PET/CT were superior to WBS (p<0.001) in all patient groups. SPECT/CT was superior to WBS and PET/CT (p<0.001) in patients who received a single challenge of radioiodine therapy, whereas PET/CT was superior to WBS (p=0.005) and SPECT/CT (p=0.013) in patients who received multiple challenges. Both SPECT/CT and PET/CT demonstrated high diagnostic performance in detecting metastatic thyroid cancer. SPECT/CT was highly accurate in patients who underwent a single challenge of radioiodine therapy. In contrast, {sup 18}F-FDG PET/CT presented the highest diagnostic performance in patients who underwent multiple challenges of radioiodine therapy. (orig.)

  2. An integral design strategy combining optical system and image processing to obtain high resolution images

    Science.gov (United States)

    Wang, Jiaoyang; Wang, Lin; Yang, Ying; Gong, Rui; Shao, Xiaopeng; Liang, Chao; Xu, Jun

    2016-05-01

    In this paper, an integral design that combines optical system with image processing is introduced to obtain high resolution images, and the performance is evaluated and demonstrated. Traditional imaging methods often separate the two technical procedures of optical system design and imaging processing, resulting in the failures in efficient cooperation between the optical and digital elements. Therefore, an innovative approach is presented to combine the merit function during optical design together with the constraint conditions of image processing algorithms. Specifically, an optical imaging system with low resolution is designed to collect the image signals which are indispensable for imaging processing, while the ultimate goal is to obtain high resolution images from the final system. In order to optimize the global performance, the optimization function of ZEMAX software is utilized and the number of optimization cycles is controlled. Then Wiener filter algorithm is adopted to process the image simulation and mean squared error (MSE) is taken as evaluation criterion. The results show that, although the optical figures of merit for the optical imaging systems is not the best, it can provide image signals that are more suitable for image processing. In conclusion. The integral design of optical system and image processing can search out the overall optimal solution which is missed by the traditional design methods. Especially, when designing some complex optical system, this integral design strategy has obvious advantages to simplify structure and reduce cost, as well as to gain high resolution images simultaneously, which has a promising perspective of industrial application.

  3. Axial segmentation of lungs CT scan images using canny method and morphological operation

    Science.gov (United States)

    Noviana, Rina; Febriani, Rasal, Isram; Lubis, Eva Utari Cintamurni

    2017-08-01

    Segmentation is a very important topic in digital image process. It is found simply in varied fields of image analysis, particularly within the medical imaging field. Axial segmentation of lungs CT scan is beneficial in designation of abnormalities and surgery planning. It will do to ascertain every section within the lungs. The results of the segmentation are accustomed discover the presence of nodules. The method which utilized in this analysis are image cropping, image binarization, Canny edge detection and morphological operation. Image cropping is done so as to separate the lungs areas, that is the region of interest. Binarization method generates a binary image that has 2 values with grey level, that is black and white (ROI), from another space of lungs CT scan image. Canny method used for the edge detection. Morphological operation is applied to smoothing the lungs edge. The segmentation methodology shows an honest result. It obtains an awfully smooth edge. Moreover, the image background can also be removed in order to get the main focus, the lungs.

  4. Automated extraction method for the center line of spinal canal and its application to the spinal curvature quantification in torso X-ray CT images

    Science.gov (United States)

    Hayashi, Tatsuro; Zhou, Xiangrong; Chen, Huayue; Hara, Takeshi; Miyamoto, Kei; Kobayashi, Tatsunori; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Fujita, Hiroshi

    2010-03-01

    X-ray CT images have been widely used in clinical routine in recent years. CT images scanned by a modern CT scanner can show the details of various organs and tissues. This means various organs and tissues can be simultaneously interpreted on CT images. However, CT image interpretation requires a lot of time and energy. Therefore, support for interpreting CT images based on image-processing techniques is expected. The interpretation of the spinal curvature is important for clinicians because spinal curvature is associated with various spinal disorders. We propose a quantification scheme of the spinal curvature based on the center line of spinal canal on CT images. The proposed scheme consists of four steps: (1) Automated extraction of the skeletal region based on CT number thresholding. (2) Automated extraction of the center line of spinal canal. (3) Generation of the median plane image of spine, which is reformatted based on the spinal canal. (4) Quantification of the spinal curvature. The proposed scheme was applied to 10 cases, and compared with the Cobb angle that is commonly used by clinicians. We found that a high-correlation (for the 95% confidence interval, lumbar lordosis: 0.81-0.99) between values obtained by the proposed (vector) method and Cobb angle. Also, the proposed method can provide the reproducible result (inter- and intra-observer variability: within 2°). These experimental results suggested a possibility that the proposed method was efficient for quantifying the spinal curvature on CT images.

  5. Reliability of fish size estimates obtained from multibeam imaging sonar

    Science.gov (United States)

    Hightower, Joseph E.; Magowan, Kevin J.; Brown, Lori M.; Fox, Dewayne A.

    2013-01-01

    Multibeam imaging sonars have considerable potential for use in fisheries surveys because the video-like images are easy to interpret, and they contain information about fish size, shape, and swimming behavior, as well as characteristics of occupied habitats. We examined images obtained using a dual-frequency identification sonar (DIDSON) multibeam sonar for Atlantic sturgeon Acipenser oxyrinchus oxyrinchus, striped bass Morone saxatilis, white perch M. americana, and channel catfish Ictalurus punctatus of known size (20–141 cm) to determine the reliability of length estimates. For ranges up to 11 m, percent measurement error (sonar estimate – total length)/total length × 100 varied by species but was not related to the fish's range or aspect angle (orientation relative to the sonar beam). Least-square mean percent error was significantly different from 0.0 for Atlantic sturgeon (x̄  =  −8.34, SE  =  2.39) and white perch (x̄  = 14.48, SE  =  3.99) but not striped bass (x̄  =  3.71, SE  =  2.58) or channel catfish (x̄  = 3.97, SE  =  5.16). Underestimating lengths of Atlantic sturgeon may be due to difficulty in detecting the snout or the longer dorsal lobe of the heterocercal tail. White perch was the smallest species tested, and it had the largest percent measurement errors (both positive and negative) and the lowest percentage of images classified as good or acceptable. Automated length estimates for the four species using Echoview software varied with position in the view-field. Estimates tended to be low at more extreme azimuthal angles (fish's angle off-axis within the view-field), but mean and maximum estimates were highly correlated with total length. Software estimates also were biased by fish images partially outside the view-field and when acoustic crosstalk occurred (when a fish perpendicular to the sonar and at relatively close range is detected in the side lobes of adjacent beams). These sources of

  6. Noncardiac findings on cardiac CT. Part II: spectrum of imaging findings.

    LENUS (Irish Health Repository)

    Killeen, Ronan P

    2012-02-01

    Cardiac computed tomography (CT) has evolved into an effective imaging technique for the evaluation of coronary artery disease in selected patients. Two distinct advantages over other noninvasive cardiac imaging methods include its ability to directly evaluate the coronary arteries and to provide a unique opportunity to evaluate for alternative diagnoses by assessing the extracardiac structures, such as the lungs and mediastinum, particularly in patients presenting with the chief symptom of acute chest pain. Some centers reconstruct a small field of view (FOV) cropped around the heart but a full FOV (from skin to skin in the area irradiated) is obtainable in the raw data of every scan so that clinically relevant noncardiac findings are identifiable. Debate in the scientific community has centered on the necessity for this large FOV. A review of noncardiac structures provides the opportunity to make alternative diagnoses that may account for the patient\\'s presentation or to detect important but clinically silent problems such as lung cancer. Critics argue that the yield of biopsy-proven cancers is low and that the follow-up of incidental noncardiac findings is expensive, resulting in increased radiation exposure and possibly unnecessary further testing. In this 2-part review we outline the issues surrounding the concept of the noncardiac read, looking for noncardiac findings on cardiac CT. Part I focused on the pros and cons for and against the practice of identifying noncardiac findings on cardiac CT. Part II illustrates the imaging spectrum of cardiac CT appearances of benign and malignant noncardiac pathology.

  7. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  8. Free radical reaction in ischemic rat brain. ESR-CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kayama, Takamasa [Yamagata Univ. (Japan). School of Medicine

    1998-07-01

    Free radical change in images of rat brain during brain ischemia was observed by using a rapid scan L-band ESR-CT system. Male Wistar rats weighing 200 g were used. Rats were divided into three groups according to the duration of occlusion of 2, 4, and 8 hr as well as a control, sham-operated group. C-PROXYL dissolved in saline solution was used as an imaging agent and injected intraperitoneally in a volume of 3 ml at a concentration of 0.3 M at the beginning of reperfusion. ESR-CT imaging was performed 20 min after injection of C-PROXYL. In the sham-operated group, histological examination disclosed no ischemic lesion. Because C-PROXYL does not pass the blood-brain barrier, no brain image was obtained. In the 2 hr occlusion ischemic group, histological findings revealed spongioid change at the dorsal putamen. The ESR-CT image showed a small spot of uptake of nitroxide radicals in the area of the presumed left putamen which corresponded to the histological ischemic lesion. In the 8 hr occlusion group, the ischemic lesion was found even in the cerebral cortex. The image of nitroxide radical in the brain again closely corresponded to the histological ischemic area and occupied most of the left cerebral hemisphere. However, the area of ESR-CT image was wider than that of histological ischemic lesion. This may be because C-PROXYL leakage in the ischemic lesion diffuses and also because the extent of the efficiency of scavenging free radicals may decline. (K.H.)

  9. Accuracy of quantitative reconstructions in SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shcherbinin, S; Celler, A [Department of Radiology, University of British Columbia, 366-828 West 10th Avenue, Vancouver BC, V5Z 1L8 (Canada); Belhocine, T; Vanderwerf, R; Driedger, A [Department of Nuclear Medicine, London Health Sciences Centre, 375 South Street, PO Box 5375, London ON, N6A 4G5 (Canada)], E-mail: shcher2@interchange.ubc.ca

    2008-09-07

    The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition protocols. Two radioactive sources were centrally and peripherally placed inside an anthropometric Thorax phantom filled with non-radioactive water. Corrections for attenuation, scatter, collimator blurring and collimator septal penetration were applied and their contribution to the overall accuracy of the reconstruction was evaluated. Reconstruction with the most comprehensive set of corrections resulted in activity estimation with error levels of 3-5% for all the isotopes.

  10. CT imaging vs. traditional radiographic imaging for evaluating Harris Lines in tibiae

    DEFF Research Database (Denmark)

    Primeau, Charlotte; Jakobsen, Lykke Schrøder; Lynnerup, Niels

    2016-01-01

    This paper is the first to systematically investigate computer tomography (CT) images vs. ordinary flat plane radiography for evaluating Harris Lines (HL) on tibiae. Harris Lines are traditionally investigated using radiographic images and recorded as either present or absent, or by counting...

  11. New approach for the pelvic registration and fusion of CT and MR images

    Science.gov (United States)

    Liu, Yuh-Hwan; Sun, Yung-Nien; Chiou, Jong-Iuan

    1997-04-01

    This paper presents a two-passed registration method to register the pelvic CT and MR images. The geometrical relationship between CT and Mr images is determined by some uniquely selected internal landmarks which are all located on the coxal bone. Thus, it can be assumed to be a rigid transformation. In the first passed registration, the relative feature vectors, such as the normal vectors, such as the normal vectors of acetabular rim planes and the vector connecting two centroids of rims, are extracted and used for registration. The relative feature vectors determined based on the edge of acetabular rims are one of few features which can be observed on both CT and Mr images. The registration results based on the relative feature vectors are less influenced by the variation in the accuracy of the detection of absolute feature points. In the second passed registration, the corner points of sacrum are used to eliminate the distortion in z-directions. The least square error approximation is used to obtain the transformation matrix in both registration passes. In addition, a complete system is developed to provide clinicians with all image processing operations and visualization. For the visualization of fused data, 2D overlapping display and 3D transparent display are used to illustrate the correspondence of different structures, including bones and soft tissues. The fused images well demonstrate the information from two complementary modalities and are highly appreciated in clinical applications.

  12. Lesion area detection using source image correlation coefficient for CT perfusion imaging.

    Science.gov (United States)

    Fan Zhu; Rodriguez Gonzalez, David; Carpenter, Trevor; Atkinson, Malcolm; Wardlaw, Joanna

    2013-09-01

    Computer tomography (CT) perfusion imaging is widely used to calculate brain hemodynamic quantities such as cerebral blood flow, cerebral blood volume, and mean transit time that aid the diagnosis of acute stroke. Since perfusion source images contain more information than hemodynamic maps, good utilization of the source images can lead to better understanding than the hemodynamic maps alone. Correlation-coefficient tests are used in our approach to measure the similarity between healthy tissue time-concentration curves and unknown curves. This information is then used to differentiate penumbra and dead tissues from healthy tissues. The goal of the segmentation is to fully utilize information in the perfusion source images. Our method directly identifies suspected abnormal areas from perfusion source images and then delivers a suggested segmentation of healthy, penumbra, and dead tissue. This approach is designed to handle CT perfusion images, but it can also be used to detect lesion areas in magnetic resonance perfusion images.

  13. Multislice CT scans in patients on extracorporeal membrane oxygenation: Emphasis on hemodynamic changes and imaging pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Kao Lang; Wang, Yu Feng; Chang, Yeun Chung; Huang, Shu Chien; Chen, Shyh Jye; Chang, Chin Chen [National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei (China); Tsang, Yuk Ming [Dept. of Medical Imaging, Far Eastern Memorial Hospital, New Taipei City (China)

    2014-06-15

    This pictorial review provides the principles of extracorporeal membrane oxygenation (ECMO) support and associated CT imaging features with emphasis on the hemodynamic changes and possible imaging pitfalls encountered. It is important that radiologists in ECMO centers apply well-designed imaging protocols and familiarize themselves with post-contrast CT imaging findings in patients on ECMO.

  14. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney NSW 2006 (Australia); Siva, Shankar [Department of Radiation Oncology, Peter MacCallum Cancer Centre, and Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville VIC 3052 (Australia); Hofman, Michael S.; Callahan, Jason; Hicks, Rodney J. [Centre for Cancer Imaging, Peter MacCallum Cancer Centre and Department of Medicine, University of Melbourne, Melbourne VIC 3002 (Australia)

    2014-01-15

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant

  15. WE-G-207-05: Relationship Between CT Image Quality, Segmentation Performance, and Quantitative Image Feature Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J; Nishikawa, R [University of Pittsburgh, Pittsburgh, PA (United States); Reiser, I [The University of Chicago, Chicago, IL (United States); Boone, J [UC Davis Medical Center, Sacramento, CA (United States)

    2015-06-15

    Purpose: Segmentation quality can affect quantitative image feature analysis. The objective of this study is to examine the relationship between computed tomography (CT) image quality, segmentation performance, and quantitative image feature analysis. Methods: A total of 90 pathology proven breast lesions in 87 dedicated breast CT images were considered. An iterative image reconstruction (IIR) algorithm was used to obtain CT images with different quality. With different combinations of 4 variables in the algorithm, this study obtained a total of 28 different qualities of CT images. Two imaging tasks/objectives were considered: 1) segmentation and 2) classification of the lesion as benign or malignant. Twenty-three image features were extracted after segmentation using a semi-automated algorithm and 5 of them were selected via a feature selection technique. Logistic regression was trained and tested using leave-one-out-cross-validation and its area under the ROC curve (AUC) was recorded. The standard deviation of a homogeneous portion and the gradient of a parenchymal portion of an example breast were used as an estimate of image noise and sharpness. The DICE coefficient was computed using a radiologist’s drawing on the lesion. Mean DICE and AUC were used as performance metrics for each of the 28 reconstructions. The relationship between segmentation and classification performance under different reconstructions were compared. Distributions (median, 95% confidence interval) of DICE and AUC for each reconstruction were also compared. Results: Moderate correlation (Pearson’s rho = 0.43, p-value = 0.02) between DICE and AUC values was found. However, the variation between DICE and AUC values for each reconstruction increased as the image sharpness increased. There was a combination of IIR parameters that resulted in the best segmentation with the worst classification performance. Conclusion: There are certain images that yield better segmentation or classification

  16. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  17. SU-E-I-13: Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Kohli, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2015-06-15

    Purpose: A new commercially available metal artifact reduction (MAR) software in computed tomography (CT) imaging was evaluated with phantoms in the presence of metals. The goal was to assess the ability of the software to restore the CT number in the vicinity of the metals without impacting the image quality. Methods: A Catphan 504 was scanned with a GE Optima RT 580 CT scanner (GE Healthcare, Milwaukee, WI) and the images were reconstructed with and without the MAR software. Both datasets were analyzed with Image Owl QA software (Image Owl Inc, Greenwich, NY). CT number sensitometry, MTF, low contrast, uniformity, noise and spatial accuracy were compared for scans with and without MAR software. In addition, an in-house made phantom was scanned with and without a stainless steel insert at three different locations. The accuracy of the CT number and metal insert dimension were investigated as well. Results: Comparisons between scans with and without MAR algorithm on the Catphan phantom demonstrate similar results for image quality. However, noise was slightly higher for the MAR algorithm. Evaluation of the CT number at various locations of the in-house made phantom was also performed. The baseline HU, obtained from the scan without metal insert, was compared to scans with the stainless steel insert at 3 different locations. The HU difference between the baseline scan versus metal scan was improved when the MAR algorithm was applied. In addition, the physical diameter of the stainless steel rod was over-estimated by the MAR algorithm by 0.9 mm. Conclusion: This work indicates with the presence of metal in CT scans, the MAR algorithm is capable of providing a more accurate CT number without compromising the overall image quality. Future work will include the dosimetric impact on the MAR algorithm.

  18. Algorithms for density and composition-discrimination imaging for fourth-generation CT systems.

    Science.gov (United States)

    Busono, P; Hussein, E M

    1999-06-01

    This paper shows that if the off-beam idle detectors in the detection ring of a fourth-generation x-ray computed tomography (CT) system are used to measure the scattered radiation, it is numerically feasible to reconstruct electron-density images to supplement the conventional attenuation-coefficient images of transmitted radiation. It is also shown that by combining these two images, composition changes can be detected with the aid of an effective-atomic-number indicator. The required image-reconstruction algorithms are developed and tested against Monte Carlo simulated measurements, for a variety of phantom configurations. In spite of the relatively poor statistical quality of scattering measurements, it is demonstrated that electron-density images of reasonable quality can be obtained. In addition, it is shown that composition discrimination is possible for materials of effective atomic number greater than five, in the photon energy range of a typical medical x-ray CT system operating at 102 kVp. The obtained supplementary electron-density and composition images can be useful in radiotherapy planning and for studying tumour histology, as well as in industrial and security applications where identification of materials based on density and composition is important.

  19. A new Level-set based Protocol for Accurate Bone Segmentation from CT Imaging

    CERN Document Server

    Pinheiro, Manuel

    2015-01-01

    In this work it is proposed a medical image segmentation pipeline for accurate bone segmentation from CT imaging. It is a two-step methodology, with a pre-segmentation step and a segmentation refinement step. First, the user performs a rough segmenting of the desired region of interest. Next, a fully automatic refinement step is applied to the pre-segmented data. The automatic segmentation refinement is composed by several sub-stpng, namely image deconvolution, image cropping and interpolation. The user-defined pre-segmentation is then refined over the deconvolved, cropped, and up-sampled version of the image. The algorithm is applied in the segmentation of CT images of a composite femur bone, reconstructed with different reconstruction protocols. Segmentation outcomes are validated against a gold standard model obtained with coordinate measuring machine Nikon Metris LK V20 with a digital line scanner LC60-D that guarantees an accuracy of 28 $\\mu m$. High sub-pixel accuracy models were obtained for all tested...

  20. Proton-induced x-ray fluorescence CT imaging.

    Science.gov (United States)

    Bazalova-Carter, Magdalena; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Matsuo, Yuto; Fahrig, Rebecca; Shirato, Hiroki; Umegaki, Kikuo; Xing, Lei

    2015-02-01

    To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%-5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm(2) CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%-5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R(2) > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Proton-induced x-ray fluorescence CT imaging of 3%-5% gold solutions in a small animal sized water phantom has been demonstrated

  1. Proton-induced x-ray fluorescence CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova-Carter, Magdalena, E-mail: bazalova@stanford.edu; Xing, Lei [Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 and Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 060-8648 (Japan); Ahmad, Moiz [Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Matsuura, Taeko; Takao, Seishin; Shirato, Hiroki; Umegaki, Kikuo [Department of Medical Physics, Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo 060-8648, Japan and Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 060-8648 (Japan); Matsuo, Yuto [Department of Medical Physics, Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo 060-8648 (Japan); Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2015-02-15

    Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm{sup 2} CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R{sup 2} > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a

  2. CT enterography for Crohn's disease: optimal technique and imaging issues.

    Science.gov (United States)

    Baker, Mark E; Hara, Amy K; Platt, Joel F; Maglinte, Dean D T; Fletcher, Joel G

    2015-06-01

    CT enterography (CTE) is a common examination for patients with Crohn's disease. In order to achieve high quality, diagnostic images, proper technique is required. The purpose of this treatise is to review the processes and techniques that can optimize CTE for patients with suspected or known Crohn's disease. We will review the following: (1) how to start a CT enterography program; (2) workflow issues, including patient and ordering physician education and preparation; (3) oral contrast media options and administration regimens; (4) intravenous contrast media injection for uniphasic and multiphasic studies; (5) CTE radiation dose reduction strategies and the use of iterative reconstruction in lower dose examinations; (6) image reconstruction and interpretation; (7) imaging Crohn's patients in the acute or emergency department setting; (8) limitations of CTE as well as alternatives such as MRE or barium fluoroscopic examinations; and (9) dictation templates and a common nomenclature for reporting findings of CTE in Crohn's disease. Many of the issues discussed are summarized in the Abdominal Radiology Society Consensus MDCT Enterography Acquisition Protocol for Crohn's Disease.

  3. CT imaging in acute pulmonary embolism: diagnostic strategies

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, Joachim E.; Mahnken, Andreas H.; Das, Marco; Guenther, Rolf W. [University of Technology (RWTH), Department of Diagnostic Radiology, University Hospital, Aachen (Germany); Kuettner, Axel [Eberhard Karls University, Department of Diagnostic Radiology, Tuebingen (Germany); Lell, Michael [Friedrich Alexander University, Department of Diagnostic Radiology, Erlangen (Germany)

    2005-05-01

    Computed tomography pulmonary angiography (CTA) has increasingly become accepted as a widely available, safe, cost-effective, and accurate method for a quick and comprehensive diagnosis of acute pulmonary embolism (PE). Pulmonary catheter angiography is still considered the gold standard and final imaging method in many diagnostic algorithms. However, spiral CTA has become established as the first imaging test in clinical routine due to its high negative predictive value for clinically relevant PE. Despite the direct visualization of clot material, depiction of cardiac and pulmonary function in combination with the quantification of pulmonary obstruction helps to grade the severity of PE for further risk stratification and to monitor the effect of thrombolytic therapy. Because PE and deep venous thrombosis are two different aspects of the same disease, additional indirect CT venography may be a valuable addition to the initial diagnostic algorithm - if this was positive for PE - and demonstration of the extent and localization of deep venous thrombosis has an impact on clinical management. Additional and alternate diagnoses add to the usefulness of this method. Using advanced multislice spiral CT technology, some practitioners have advocated CTA as the sole imaging tool for routine clinical assessment in suspected acute PE. This will simplify standards of practice in the near future. (orig.)

  4. The algorithm study for using the back propagation neural network in CT image segmentation

    Science.gov (United States)

    Zhang, Peng; Liu, Jie; Chen, Chen; Li, Ying Qi

    2017-01-01

    Back propagation neural network(BP neural network) is a type of multi-layer feed forward network which spread positively, while the error spread backwardly. Since BP network has advantages in learning and storing the mapping between a large number of input and output layers without complex mathematical equations to describe the mapping relationship, it is most widely used. BP can iteratively compute the weight coefficients and thresholds of the network based on the training and back propagation of samples, which can minimize the error sum of squares of the network. Since the boundary of the computed tomography (CT) heart images is usually discontinuous, and it exist large changes in the volume and boundary of heart images, The conventional segmentation such as region growing and watershed algorithm can't achieve satisfactory results. Meanwhile, there are large differences between the diastolic and systolic images. The conventional methods can't accurately classify the two cases. In this paper, we introduced BP to handle the segmentation of heart images. We segmented a large amount of CT images artificially to obtain the samples, and the BP network was trained based on these samples. To acquire the appropriate BP network for the segmentation of heart images, we normalized the heart images, and extract the gray-level information of the heart. Then the boundary of the images was input into the network to compare the differences between the theoretical output and the actual output, and we reinput the errors into the BP network to modify the weight coefficients of layers. Through a large amount of training, the BP network tend to be stable, and the weight coefficients of layers can be determined, which means the relationship between the CT images and the boundary of heart.

  5. Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Leschka, Sebastian; Husmann, Lars; Desbiolles, Lotus M.; Boehm, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Gaemperli, Oliver; Schepis, Tiziano; Koepfli, Pascal [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Center for Integrative Human Physiology, Zurich (Switzerland)

    2006-09-15

    The reconstruction intervals providing best image quality for non-invasive coronary angiography with 64-slice computed tomography (CT) were evaluated. Contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT coronary angiography was performed in 80 patients (47 male, 33 female; mean age 62.1{+-}10.6 years). Thirteen data sets were reconstructed in 5% increments from 20 to 80% of the R-R interval. Depending on the average heart rate during scanning, patients were grouped as <65 bpm (n=49) and {>=}65 bpm (n=31). Two blinded and independent readers assessed the image quality of each coronary segment with a diameter {>=}1.5 mm using the following scores: 1, no motion artifacts; 2, minor artifacts; 3, moderate artifacts; 4, severe artifacts; and 5, not evaluative. The average heart rate was 63.3{+-}13.1 bpm (range 38-102). Acceptable image quality (scores 1-3) was achieved in 99.1% of all coronary segments (1,162/1,172; mean image quality score 1.55{+-}0.77) in the best reconstruction interval. Best image quality was found at 60% and 65% of the R-R interval for all patients and for each heart rate subgroup, whereas motion artifacts occurred significantly more often (P<0.01) at other reconstruction intervals. At heart rates <65 bpm, acceptable image quality was found in all coronary segments at 60%. At heart rates {>=}65 bpm, the whole coronary artery tree could be visualized with acceptable image quality in 87% (27/31) of the patients at 60%, while ten segments in four patients were rated as non-diagnostic (scores 4-5) at any reconstruction interval. In conclusion, 64-slice CT coronary angiography provides best overall image quality in mid-diastole. At heart rates <65 bpm, diagnostic image quality of all coronary segments can be obtained at a single reconstruction interval of 60%. (orig.)

  6. Segmentation and separation of venous vasculatures in liver CT images

    Science.gov (United States)

    Wang, Lei; Hansen, Christian; Zidowitz, Stephan; Hahn, Horst K.

    2014-03-01

    Computer-aided analysis of venous vasculatures including hepatic veins and portal veins is important in liver surgery planning. The analysis normally consists of two important pre-processing tasks: segmenting both vasculatures and separating them from each other by assigning different labels. During the acquisition of multi-phase CT images, both of the venous vessels are enhanced by injected contrast agent and acquired either in a common phase or in two individual phases. The enhanced signals established by contrast agent are often not stably acquired due to non-optimal acquisition time. Inadequate contrast and the presence of large lesions in oncological patients, make the segmentation task quite challenging. To overcome these diffculties, we propose a framework with minimal user interactions to analyze venous vasculatures in multi-phase CT images. Firstly, presented vasculatures are automatically segmented adopting an efficient multi-scale Hessian-based vesselness filter. The initially segmented vessel trees are then converted to a graph representation, on which a series of graph filters are applied in post-processing steps to rule out irrelevant structures. Eventually, we develop a semi-automatic workow to refine the segmentation in the areas of inferior vena cava and entrance of portal veins, and to simultaneously separate hepatic veins from portal veins. Segmentation quality was evaluated with intensive tests enclosing 60 CT images from both healthy liver donors and oncological patients. To quantitatively measure the similarities between segmented and reference vessel trees, we propose three additional metrics: skeleton distance, branch coverage, and boundary surface distance, which are dedicated to quantifying the misalignment induced by both branching patterns and radii of two vessel trees.

  7. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Colin D.; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H.; Parmar, Hemant A. [University of Michigan, Department of Radiology, Ann Arbor, MI (United States)

    2014-08-15

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDI{sub vol}) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDI{sub vol} value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDI{sub vol} for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDI{sub vol} in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the

  8. Comparison of CT and MRI brain tumor imaging using a canine glioma model.

    Science.gov (United States)

    Whelan, H T; Clanton, J A; Wilson, R E; Tulipan, N B

    1988-01-01

    A canine gliosarcoma model was used to study the effectiveness of magnetic resonance imaging (MRI) with gadolinium contrast enhancement in defining the histologic margins of brain tumors. The effectiveness of this technique was compared to conventional computed tomography (CT) using iodinated contrast enhancement. Cultured canine gliosarcoma cells were injected into the left hemisphere of adult mongrel dogs. The dogs developed brain tumors and progressive clinical signs. Serial MRI with and without gadolinium diethylene triamine penta-acetic acid was compared to serial CT with and without sodium iothalamate obtained on the same days. After the final scans, animals were sacrificed; the brains were removed and processed for routine histopathologic study. All tumors were visualized with contrast-enhanced MRI which proved most sensitive. Gadolinium di-ethylene triamine penta-acetic acid caused bright enhancement of tumors in a distribution that consistently corresponded to areas of pathologically proved tumor infiltration. Gross and microscopic autopsy findings correlated better with MRI than with CT which tended to produce poorer resolution and underrepresent the size of viable tumor. Gadolinium-enhanced MRI is more accurate than unenhanced MRI, unenhanced CT, or enhanced CT in defining the histologic margins of tumors.

  9. FDG PET/CT imaging in canine cancer patients

    DEFF Research Database (Denmark)

    Hansen, Anders Elias; McEvoy, Fintan; Engelholm, Svend Aage;

    2011-01-01

    and organs in canine cancer patients. FDG PET/CT was performed in 14 dogs including, nine mesenchymal tumors, four carcinomas, and one incompletely excised mast cell tumor. A generally higher FDG uptake was observed in carcinomas relative to sarcomas. Maximum SUV of carcinomas ranged from 7.6 to 27.......0, and for sarcomas from 2.0 to 10.6. The FDG SUV of several organs and tissues, including regional brain uptake is reported, to serve as a reference for future FDG PET studies in canine cancer patients. Several potential pitfalls have been recognized in interpretation of FDG PET images of human patients, a number...

  10. Metastatic meningioma: positron emission tomography CT imaging findings.

    LENUS (Irish Health Repository)

    Brennan, C

    2010-12-01

    The imaging findings of a case of metastasing meningioma are described. The case illustrates a number of rare and interesting features. The patient presented with haemoptysis 22 years after the initial resection of an intracranial meningioma. CT demonstrated heterogeneous masses with avid peripheral enhancement without central enhancement. Blood supply to the larger lesion was partially from small feeding vessels from the inferior pulmonary vein. These findings correlate with a previously published case in which there was avid uptake of fluoro-18-deoxyglucose peripherally with lesser uptake centrally. The diagnosis of metastasing meningioma was confirmed on percutaneous lung tissue biopsy.

  11. Wide coverage by volume CT: benefits for cardiac imaging

    Science.gov (United States)

    Sablayrolles, Jean-Louis; Cesmeli, Erdogan; Mintandjian, Laura; Adda, Olivier; Dessalles-Martin, Diane

    2005-04-01

    With the development of new technologies, computed tomography (CT) is becoming a strong candidate for non-invasive imaging based tool for cardiac disease assessment. One of the challenges of cardiac CT is that a typical scan involves a breath hold period consisting of several heartbeats, about 20 sec with scanners having a longitudinal coverage of 2 cm, and causing the image quality (IQ) to be negatively impacted since beat to beat variation is high likely to occur without any medication, e.g. beta blockers. Because of this and the preference for shorter breath hold durations, a CT scanner with a wide coverage without the compromise in the spatial and temporal resolution of great clinical value. In this study, we aimed at determining the optimum scan duration and the delay relative to beginning of breath hold, to achieve high IQ. We acquired EKG data from 91 consecutive patients (77 M, 14 F; Age: 57 +/- 14) undergoing cardiac CT exams with contrast, performed on LightSpeed 16 and LightSpeed Pro16. As an IQ metric, we adopted the standard deviation of "beat-to-beat variation" (stdBBV) within a virtual scan period. Two radiologists evaluated images by assigning a score of 1 (worst) to 4 best). We validated stdBBV with the radiologist scores, which resulted in a population distribution of 9.5, 9.5, 31, and 50% for the score groups 1, 2, 3, and 4, respectively. Based on the scores, we defined a threshold for stdBBV and identified an optimum combination of virtual scan period and a delay. With the assumption that the relationship between the stdBBV and diagnosable scan IQ holds, our analysis suggested that the success rate can be improved to 100% with scan durations equal or less than 5 sec with a delay of 1 - 2 sec. We confirmed the suggested conclusion with LightSpeed VCT (GE Healthcare Technologies, Waukesha, WI), which has a wide longitudinal coverage, fine isotropic spatial resolution, and high temporal resolution, e.g. 40 mm coverage per rotation of 0.35 sec

  12. Metastatic meningioma: positron emission tomography CT imaging findings

    Science.gov (United States)

    Brennan, C; O'Connor, O J; O'Regan, K N; Keohane, C; Dineen, J; Hinchion, J; Sweeney, B; Maher, M M

    2010-01-01

    The imaging findings of a case of metastasing meningioma are described. The case illustrates a number of rare and interesting features. The patient presented with haemoptysis 22 years after the initial resection of an intracranial meningioma. CT demonstrated heterogeneous masses with avid peripheral enhancement without central enhancement. Blood supply to the larger lesion was partially from small feeding vessels from the inferior pulmonary vein. These findings correlate with a previously published case in which there was avid uptake of fluoro-18-deoxyglucose peripherally with lesser uptake centrally. The diagnosis of metastasing meningioma was confirmed on percutaneous lung tissue biopsy. PMID:21088084

  13. CT images of an anthropomorphic and anthropometric male pelvis phantom

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  14. CT and MR Imagings of Semicircular Canal Aplasia

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chung Hee; Hong, Hyun Sook; Yi, Beom Ha; Cha, Jang Gyu; Park, Seong Jin; Kim, Dae Ho; Lee, Hae Kyung; Kim, Shi Chan [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2009-07-15

    To evaluate the clinical, CT and MR imaging findings of semicircular canal (SCC) aplasia and to evaluate if a correlation exists between these findings and the associated anomalies or syndromes. This study retrospectively reviewed the CT and MRI findings of five patients with SCC aplasia. The CT and MR findings were analyzed for SCC, direction of facial nerve canal, cochlea, vestibule, oval or round window, middle ear ossicles, and internal auditory canal (IAC). The subjects included three boys and two girls ranging in age from one to 120 months (mean age; 51 months). Four of the subjects had the CHARGE syndrome, and one had the Goldenhar syndrome. Moreover, four subjects had sensorineural hearing loss and one had combined hearing loss. The course of the facial nerve canal was abnormal in all five cases. Moreover, trapped cochlea and dysplastic modiolus were each observed in one case. Four subjects had atresia of the oval window; whereas ankylosis of the ossicles was present in three subjects. IAC stenosis was present in one patient with the CHARGE syndrome. The aberrant course of the facial nerve canal, atresia of the oval window, and abnormal ossicles were frequently associated in patients with SCC aplasia. In addition, the Goldenhar and CHARGE syndromes were also commonly associated syndromes.

  15. Ultra-filtration measurement using CT imaging technology

    Energy Technology Data Exchange (ETDEWEB)

    Lu Junfeng [Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, No.2 Beiyitiao Street, Zhongguancun, Haidian District, Beijing, 100190 (China); Lu Wenqiang, E-mail: junfenglu@mail.ipc.ac.c [Graduate University of Chinese Academy of Sciences, No.19A Yuquan Road, Shijingshan District, Beijing, 100049 (China)

    2009-02-01

    As a functional unit in the hemodialysis process, dialyzer captured quite a few medical research interests since 1980s. In the design of dialyzer or in the ongoing hemodialysis process, to estimate the ultra-filtration amount of a dialyzer, the sideway loss of the running blood flow through hollow fibers or filtration channels should be measured. This further leads to the measurement of the blood flow inside the dialyzer. For this measurement, a non-invasive method is highly desired because of the high-dense bundled hollow fibers or packed channels inside the dialyzer. As non-invasive measurement tools, CT (Computed Tomography) technologies were widely used for tissue, bone, and cancerous clinical analyses etc .... Thus, in this paper, a CT system is adopted to predict the blood flow inside a hollow fiber dialyzer. In view of symmetric property of the hollow fiber dialyzer, the largest cutting plane that parallels to the cylindrical dialyzer was analyzed by the CT system dynamically. And then, a noninvasive image analysis method used to predict the ultra-filtration amount is proposed.

  16. Making renal stones change size-impact of CT image post processing and reader variability.

    Science.gov (United States)

    Lidén, Mats; Andersson, Torbjörn; Geijer, Håkan

    2011-10-01

    The objectives of this study were to quantify the impact of image post-processing parameters on the apparent renal stone size, and to quantify the intra- and inter-reader variability in renal stone size estimation. Fifty CT datasets including a renal or ureteral stone were included retrospectively during a prospective inclusion period. Each of the CT datasets was post-processed in different ways regarding slice thickness, slice increment and window setting. In the first part of the study a single reader repeated size estimations for the renal stones using different post-processing parameters. In the intra-reader variability experiment one reader reported size estimations for the same images with a one-week interval. The inter-reader variability data were obtained from 11 readers reporting size estimations for the same renal stones. The apparent stone size differed according to image post-processing parameters with the largest mean differences seen with regard to the window settings experiment (1.5 mm, p reader variability was considerably larger than the intra-reader variability. Our results indicate a need for the standardisation of making measurements on CT images.

  17. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  18. Deep convolutional networks for pancreas segmentation in CT imaging

    Science.gov (United States)

    Roth, Holger R.; Farag, Amal; Lu, Le; Turkbey, Evrim B.; Summers, Ronald M.

    2015-03-01

    Automatic organ segmentation is an important prerequisite for many computer-aided diagnosis systems. The high anatomical variability of organs in the abdomen, such as the pancreas, prevents many segmentation methods from achieving high accuracies when compared to state-of-the-art segmentation of organs like the liver, heart or kidneys. Recently, the availability of large annotated training sets and the accessibility of affordable parallel computing resources via GPUs have made it feasible for "deep learning" methods such as convolutional networks (ConvNets) to succeed in image classification tasks. These methods have the advantage that used classification features are trained directly from the imaging data. We present a fully-automated bottom-up method for pancreas segmentation in computed tomography (CT) images of the abdomen. The method is based on hierarchical coarse-to-fine classification of local image regions (superpixels). Superpixels are extracted from the abdominal region using Simple Linear Iterative Clustering (SLIC). An initial probability response map is generated, using patch-level confidences and a two-level cascade of random forest classifiers, from which superpixel regions with probabilities larger 0.5 are retained. These retained superpixels serve as a highly sensitive initial input of the pancreas and its surroundings to a ConvNet that samples a bounding box around each superpixel at different scales (and random non-rigid deformations at training time) in order to assign a more distinct probability of each superpixel region being pancreas or not. We evaluate our method on CT images of 82 patients (60 for training, 2 for validation, and 20 for testing). Using ConvNets we achieve maximum Dice scores of an average 68% +/- 10% (range, 43-80%) in testing. This shows promise for accurate pancreas segmentation, using a deep learning approach and compares favorably to state-of-the-art methods.

  19. Interior tomography in x-ray differential phase contrast CT imaging

    Science.gov (United States)

    Thériault Lauzier, Pascal; Qi, Zhihua; Zambelli, Joseph; Bevins, Nicholas; Chen, Guang-Hong

    2012-05-01

    Differential phase contrast computed tomography (DPC-CT) is an x-ray imaging method that uses the wave properties of imaging photons as the contrast mechanism. It has been demonstrated that DPC images can be obtained using a conventional x-ray tube and a Talbot-Lau-type interferometer. Due to the limited size of the gratings, current data acquisition systems only offer a limited field of view, and thus are prone to data truncation. As a result, the reconstructed DPC-CT image may suffer from image artifacts and increased inaccuracy in the reconstructed image values. In this paper, we demonstrate that a small region of interest (ROI) within a large object can be accurately and stably reconstructed using fully truncated projection datasets provided that a priori information on electron density is known for a small region inside the ROI. The method reconstructs an image iteratively to satisfy a group of physical conditions by using a projection onto convex set (POCS) approach. In this work, this POCS algorithm is validated using both numerical simulations and physical phantom experimental data. In both cases, the root mean square error is reduced by an order of magnitude with respect to the truncated analytic reconstructions. Truncation artifacts observed in the latter reconstructions are eliminated using the POCS algorithm.

  20. Optimization of the imaging quality of 64-slice CT acquisition protocol using Taguchi analysis: A phantom study.

    Science.gov (United States)

    Pan, Lung Fa; Erdene, Erdenetsetseg; Chen, Chun Chi; Pan, Lung Kwang

    2015-01-01

    In this study, the phantom imaging quality of 64-slice CT acquisition protocol was quantitatively evaluated using Taguchi. The phantom acrylic line group was designed and assembled with multiple layers of solid water plate in order to imitate the adult abdomen, and scanned with Philips brilliance CT in order to simulate a clinical examination. According to the Taguchi L8(2(7)) orthogonal array, four major factors of the acquisition protocol were optimized, including (A) CT slice thickness, (B) the image reconstruction filter type, (C) the spiral CT pitch, and (D) the matrix size. The reconstructed line group phantom image was counted by four radiologists for three discrete rounds in order to obtain the averages and standard deviations of the line counts and the corresponding signal to noise ratios (S/N). The quantified S/N values were analyzed and the optimal combination of the four factor settings was determined to be comprised of (A) a 1-mm thickness, (B) a sharp filter type, (C) a 1.172 spiral CT pitch, and (D) a 1024×1024 matrix size. The dominant factors included the (A) filter type and the cross interaction between the filter type and CT slice thickness (A×B). The minor factors were determined to be (C) the spiral CT pitch and (D) the matrix size since neither was capable of yielding a 95% confidence level in the ANOVA test.

  1. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  2. Automated segmentation of knee and ankle regions of rats from CT images to quantify bone mineral density for monitoring treatments of rheumatoid arthritis

    Science.gov (United States)

    Cruz, Francisco; Sevilla, Raquel; Zhu, Joe; Vanko, Amy; Lee, Jung Hoon; Dogdas, Belma; Zhang, Weisheng

    2014-03-01

    Bone mineral density (BMD) obtained from a CT image is an imaging biomarker used pre-clinically for characterizing the Rheumatoid arthritis (RA) phenotype. We use this biomarker in animal studies for evaluating disease progression and for testing various compounds. In the current setting, BMD measurements are obtained manually by selecting the regions of interest from three-dimensional (3-D) CT images of rat legs, which results in a laborious and low-throughput process. Combining image processing techniques, such as intensity thresholding and skeletonization, with mathematical techniques in curve fitting and curvature calculations, we developed an algorithm for quick, consistent, and automatic detection of joints in large CT data sets. The implemented algorithm has reduced analysis time for a study with 200 CT images from 10 days to 3 days and has improved the robust detection of the obtained regions of interest compared with manual segmentation. This algorithm has been used successfully in over 40 studies.

  3. MUTUAL INFORMATION BASED 3D NON-RIGID REGISTRATION OF CT/MR ABDOMEN IMAGES

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A mutual information based 3D non-rigid registration approach was proposed for the registration of deformable CT/MR body abdomen images. The Parzen Windows Density Estimation (PWDE) method is adopted to calculate the mutual information between the two modals of CT and MRI abdomen images. By maximizing MI between the CT and MR volume images, the overlapping part of them reaches the biggest, which means that the two body images of CT and MR matches best to each other. Visible Human Project (VHP) Male abdomen CT and MRI Data are used as experimental data sets. The experimental results indicate that this approach of non-rigid 3D registration of CT/MR body abdominal images can be achieved effectively and automatically, without any prior processing procedures such as segmentation and feature extraction, but has a main drawback of very long computation time. Key words: medical image registration; multi-modality; mutual information; non-rigid; Parzen window density estimation

  4. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    DEFF Research Database (Denmark)

    Thing, Rune Slot; Bernchou, Uffe; Mainegra-Hing, Ernesto

    2016-01-01

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five ...

  5. Imaging of rhinosinusitis and its complications: plain film, CT, and MRI.

    Science.gov (United States)

    Mafee, Mahmood F; Tran, Brandon H; Chapa, Ajay R

    2006-06-01

    Conventional plain-film radiography may be used as a screening method for various pathological conditions of the sinonasal cavities. However, CT scanning remains the study of choice for the imaging evaluation of acute and chronic inflammatory diseases of sinonasal cavities. MRI is superior to CT in differentiating inflammatory conditions from neoplastic processes. The most common complications of rhinosinusitis in children occur in the orbit. The information obtained from the CT scan and MRI, together with clinical findings, may be the best guidelines for clinical management and the mode of treatment. Although intracranial complications of sinusitis are relatively rare, prompt recognition of these disease states is important to prevent permanent neurological deficit or fatality. It is prudent to obtain MRI of the sinuses, orbits, and brain whenever extensive or multiple complications of sinusitis are suspected, in addition to CT scanning. Chronic rhinosinusitis is a clinical diagnosis, confirmed and staged with the CT scan of sinonasal cavities. Chronic inflammatory disease is often associated with mucosal thickening and sclerosis of the bone, particularly within the sinuses. Chronic extramucosal fungal sinusitis develops as a saprophytic growth in retained secretions in a sinus cavity. The imaging manifestations of chronic mycotic rhinosinusitis may be nonspecific or highly suggestive of the presence of fungal infection. The presence of diffuse increased attenuation within the paranasal sinuses and nasal cavity should be considered as chronic allergic hypersensitivity aspergillosis (chronic noninvasive aspergillosis) or chronic hyperplastic sinusitis and polyposis associated with desiccated, retained mucosal secretions. The MRI characteristics of fungal sinusitis depend on the stage of the disease.

  6. A compressed sensing-based iterative algorithm for CT reconstruction and its possible application to phase contrast imaging

    Directory of Open Access Journals (Sweden)

    Li Xueli

    2011-08-01

    Full Text Available Abstract Background Computed Tomography (CT is a technology that obtains the tomogram of the observed objects. In real-world applications, especially the biomedical applications, lower radiation dose have been constantly pursued. To shorten scanning time and reduce radiation dose, one can decrease X-ray exposure time at each projection view or decrease the number of projections. Until quite recently, the traditional filtered back projection (FBP method has been commonly exploited in CT image reconstruction. Applying the FBP method requires using a large amount of projection data. Especially when the exposure speed is limited by the mechanical characteristic of the imaging facilities, using FBP method may prolong scanning time and cumulate with a high dose of radiation consequently damaging the biological specimens. Methods In this paper, we present a compressed sensing-based (CS-based iterative algorithm for CT reconstruction. The algorithm minimizes the l1-norm of the sparse image as the constraint factor for the iteration procedure. With this method, we can reconstruct images from substantially reduced projection data and reduce the impact of artifacts introduced into the CT reconstructed image by insufficient projection information. Results To validate and evaluate the performance of this CS-base iterative algorithm, we carried out quantitative evaluation studies in imaging of both software Shepp-Logan phantom and real polystyrene sample. The former is completely absorption based and the later is imaged in phase contrast. The results show that the CS-based iterative algorithm can yield images with quality comparable to that obtained with existing FBP and traditional algebraic reconstruction technique (ART algorithms. Discussion Compared with the common reconstruction from 180 projection images, this algorithm completes CT reconstruction from only 60 projection images, cuts the scan time, and maintains the acceptable quality of the

  7. Assessment of pulmonary hypertension by CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ley, Sebastian [Department of Radiology, Deutsches Krebsforschungszentrum, Im Neuenheimer Feld 280, 69120, Heidelberg (Germany); Department of Radiology, Johannes Gutenberg University, Langenbeckstrasse 1, 55131, Mainz (Germany); Kreitner, Karl-Friedrich; Heussel, Claus P. [Department of Radiology, Johannes Gutenberg University, Langenbeckstrasse 1, 55131, Mainz (Germany); Fink, Christian; Kauczor, Hans-Ulrich [Department of Radiology, Deutsches Krebsforschungszentrum, Im Neuenheimer Feld 280, 69120, Heidelberg (Germany); Borst, Mathias M. [Department of Internal Medicine III, Ruprecht-Karls University, Heidelberg (Germany)

    2004-03-01

    In the recent World Health Organization (WHO) classification the group of pulmonary arterial hypertension (PH) comprises the classic primary pulmonary hypertension and several conditions with definite or very high risk factors to develop pulmonary arterial hypertension. Therapeutic advances drive the need for a comprehensive pre-therapeutic evaluation for optimal treatment. Furthermore, follow-up examinations need to be performed to monitor changes in disease status and response to therapy. Up to now, the diagnostic imaging work-up of PH comprises mainly echocardiography, invasive right heart catheterization and ventilation/perfusion scintigraphy. Due to technical advances helical computed tomography (CT) and magnetic resonance imaging (MRI) became more important in the evaluation and for differential diagnosis of pulmonary arterial hypertension. Both modalities are reviewed and recommendations for clinical use are given. (orig.)

  8. [A novel denoising approach to SVD filtering based on DCT and PCA in CT image].

    Science.gov (United States)

    Feng, Fuqiang; Wang, Jun

    2013-10-01

    Because of various effects of the imaging mechanism, noises are inevitably introduced in medical CT imaging process. Noises in the images will greatly degrade the quality of images and bring difficulties to clinical diagnosis. This paper presents a new method to improve singular value decomposition (SVD) filtering performance in CT image. Filter based on SVD can effectively analyze characteristics of the image in horizontal (and/or vertical) directions. According to the features of CT image, we can make use of discrete cosine transform (DCT) to extract the region of interest and to shield uninterested region so as to realize the extraction of structure characteristics of the image. Then we transformed SVD to the image after DCT, constructing weighting function for image reconstruction adaptively weighted. The algorithm for the novel denoising approach in this paper was applied in CT image denoising, and the experimental results showed that the new method could effectively improve the performance of SVD filtering.

  9. Constrain static target kinetic iterative image reconstruction for 4D cardiac CT imaging

    Science.gov (United States)

    Alessio, Adam M.; La Riviere, Patrick J.

    2011-03-01

    Iterative image reconstruction offers improved signal to noise properties for CT imaging. A primary challenge with iterative methods is the substantial computation time. This computation time is even more prohibitive in 4D imaging applications, such as cardiac gated or dynamic acquisition sequences. In this work, we propose only updating the time-varying elements of a 4D image sequence while constraining the static elements to be fixed or slowly varying in time. We test the method with simulations of 4D acquisitions based on measured cardiac patient data from a) a retrospective cardiac-gated CT acquisition and b) a dynamic perfusion CT acquisition. We target the kinetic elements with one of two methods: 1) position a circular ROI on the heart, assuming area outside ROI is essentially static throughout imaging time; and 2) select varying elements from the coefficient of variation image formed from fast analytic reconstruction of all time frames. Targeted kinetic elements are updated with each iteration, while static elements remain fixed at initial image values formed from the reconstruction of data from all time frames. Results confirm that the computation time is proportional to the number of targeted elements; our simulations suggest that 3 times reductions in reconstruction time. The images reconstructed with the proposed method have matched mean square error with full 4D reconstruction. The proposed method is amenable to most optimization algorithms and offers the potential for significant computation improvements, which could be traded off for more sophisticated system models or penalty terms.

  10. Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation.

    Science.gov (United States)

    Kaewlek, Titipong; Koolpiruck, Diew; Thongvigitmanee, Saowapak; Mongkolsuk, Manus; Thammakittiphan, Sastrawut; Tritrakarn, Siri-on; Chiewvit, Pipat

    2015-01-01

    Metal artifacts often appear in the images of computed tomography (CT) imaging. In the case of lumbar spine CT images, artifacts disturb the images of critical organs. These artifacts can affect the diagnosis, treatment, and follow up care of the patient. One approach to metal artifact reduction is the sinogram completion method. A mixed-variable thresholding (MixVT) technique to identify the suitable metal sinogram is proposed. This technique consists of four steps: 1) identify the metal objects in the image by using k-mean clustering with the soft cluster assignment, 2) transform the image by separating it into two sinograms, one of which is the sinogram of the metal object, with the surrounding tissue shown in the second sinogram. The boundary of the metal sinogram is then found by the MixVT technique, 3) estimate the new value of the missing data in the metal sinogram by linear interpolation from the surrounding tissue sinogram, 4) reconstruct a modified sinogram by using filtered back-projection and complete the image by adding back the image of the metal object into the reconstructed image to form the complete image. The quantitative and clinical image quality evaluation of our proposed technique demonstrated a significant improvement in image clarity and detail, which enhances the effectiveness of diagnosis and treatment.

  11. Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, Damien; Remy-Jardin, Martine; Rozel, Celine; Remy, Jacques [University Center of Lille, Boulevard Jules Leclerc, Department of Thoracic Imaging, Hospital Calmette, Lille cedex (France); Dusson, Catherine; Wurtz, Alain [University Center of Lille, Department of Thoracic Surgery, Hospital Calmette, Lille cedex (France); Delannoy-Deken, Valerie; Duhamel, Alain [University of Lille, Department of Medical Statistics, Lille cedex (France)

    2007-03-15

    The purpose of this study was to evaluate the clinical feasibility of coronary artery imaging during routine preoperative 64-slice MDCT scans of the chest. Ninety-nine consecutive patients in sinus rhythm underwent a biphasic multidetector-row spiral CT examination of the chest without the administration of beta-blockers, including an ECG-gated acquisition over the cardiac cavities, followed by a non-gated examination of the upper third of the thorax. Data were reconstructed to evaluate coronary arteries and to obtain presurgical staging of the underlying disease. The percentage of assessable segments ranged from 65.4% (972/1,485) when considering all coronary artery segments to 88% (613/693) for the proximal and mid segments, reaching 98% (387/396) for proximal coronary artery segments. The 387 interpretable proximal segments included 97 (97%) LM, 99 (100%) LAD, 96 (97%) LCX and 95 (96%) RCA with a mean attenuation of 280.70{+-}52.93 HU. The mean percentage of assessable segments was significantly higher in patients with a heart rate {<=}80 bpm (n=48) than in patients with a heart rate greater than 80 bpm (n=35) (80{+-}11% vs. 72{+-}13%; P=0.0008). Diagnostic image quality was achieved in all patients for preoperative staging of the underlying disorder. The mean estimated effective dose was 12.06{+-}3.25 mSv for ECG-gated scans and 13.88{+-}3.49 mSv for complete chest examinations. Proximal and mid-coronary artery segments can be adequately evaluated during presurgical CT examinations of the chest obtained with 64-slice MDCT without the administration of {beta}-blockers. (orig.)

  12. Automatic lobar segmentation for diseased lungs using an anatomy-based priority knowledge in low-dose CT images

    Science.gov (United States)

    Park, Sang Joon; Kim, Jung Im; Goo, Jin Mo; Lee, Doohee

    2014-03-01

    Lung lobar segmentation in CT images is a challenging tasks because of the limitations in image quality inherent to CT image acquisition, especially low-dose CT for clinical routine environment. Besides, complex anatomy and abnormal lesions in the lung parenchyma makes segmentation difficult because contrast in CT images are determined by the differential absorption of X-rays by neighboring structures, such as tissue, vessel or several pathological conditions. Thus, we attempted to develop a robust segmentation technique for normal and diseased lung parenchyma. The images were obtained with low-dose chest CT using soft reconstruction kernel (Sensation 16, Siemens, Germany). Our PC-based in-house software segmented bronchial trees and lungs with intensity adaptive region-growing technique. Then the horizontal and oblique fissures were detected by using eigenvalues-ratio of the Hessian matrix in the lung regions which were excluded from airways and vessels. To enhance and recover the faithful 3-D fissure plane, our proposed fissure enhancing scheme were applied to the images. After finishing above steps, for careful smoothening of fissure planes, 3-D rolling-ball algorithm in xyz planes were performed. Results show that success rate of our proposed scheme was achieved up to 89.5% in the diseased lung parenchyma.

  13. Influence of respiratory motion in the delineation of treatment volumes using CT images; Influencia del movimiento respiratorio en la delimiacion de volumenes de tratamiento mediante imagenes TC

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Romero, R.; Castro Tejero, P.

    2011-07-01

    The radiation treatments are based on geometric information and density of the CT images obtained for each patient. As a result of the motion blur produced in the imaging studies, the sizes, shapes and densities of the structures can be altered. The aim of this study was to determine the magnitude of these variations caused by respiratory motion in the CT study according to the conditions of image acquisition.

  14. 4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling

    OpenAIRE

    2008-01-01

    Four-dimensional computed tomography (4D-CT) imaging technology has been developed for radiation therapy to provide tumor and organ images at the different breathing phases. In this work, a procedure is proposed for estimating and modeling the respiratory motion field from acquired 4D-CT imaging data and predicting tissue motion at the different breathing phases. The 4D-CT image data consist of series of multislice CT volume segments acquired in ciné mode. A modified optical flow deformable i...

  15. [Characteristic of evaluation of new image filter devised for improvement of workflow in CT examination].

    Science.gov (United States)

    Hara, Takanori; Ichikawa, Katsuhiro; Tsuzaka, Masatoshi

    2005-07-20

    In this study, we processed reconstructed images with a new image filter (Siemens Medical Systems, Adaptive Image Filter: AIF). As one of its characteristics, the filter uses low-pass filtering. When an image that emphasizes a high-frequency element is changed to one with a reduced high-frequency element, an image suitable for clinical use can be obtained. For the resolving characteristic and the noise characteristic, we evaluated the degree of transition, using the modulation transfer factor (MTF) and Wiener spectrum (WS). Moreover, we used the signal-to-noise ratio (SNR) to examine the total loss of signal detection capability after use of the AIF. The results showed that, when we changed to images using the AIF and made it the same level as B30 and U40, we had to hold down the kernel level to at least B60 and U80. The use of an image filter did not recognize less of an SNR in comparison with the reconstruction image. In this study, changes in detailed characteristics of the image and SNR could be evaluated objectively using the AIF. As for the effective method by AIF that raw data isn't used for is available for the control of an image (times) using reconstruction and the change of an image on database. Therefore, we consider the AIF useful to improve workflow in CT examinations.

  16. Lack of Anatomical Concordance between Preablation and Postablation CT Images: A Risk Factor Related to Ablation Site Recurrence

    Directory of Open Access Journals (Sweden)

    Petra G. Kele

    2012-01-01

    Full Text Available Objective. Variation in the position of the liver between preablation and postablation CT images hampers assessment of treatment of colorectal liver metastasis (CRLM. The aim of this study was to test the hypothesis that discordant preablation and postablation imaging is associated with more ablation site recurrences (ASRs. Methods. Patients with CRLM were included. Index-tumor size, location, number, RFA approachs and ablative margins were obtained on CT scans. Preablation and postablation CT images were assigned a “Similarity of Positioning Score” (SiPS. A suitable cutoff was determined. Images were classified as identical (SiPS-id or nonidentical (SiPS-diff. ASR was identified prospectively on follow-up imaging. Results. Forty-seven patients with 97 tumors underwent 64 RFA procedures (39 patients/63 tumors open RFA, 25 patients/34 tumours CT-targeted RFA, 12 patients underwent >1 RFA. Images of 52 (54% ablation sites were classified as SiPS-id, 45 (46% as SiPS-diff. Index-tumor size, tumor location and number, concomitant partial hepatectomy, and RFA approach did not influence the SiPS. ASR developed in 11/47 (23% patients and 20/97 (21% tumours. ASR occurred less frequently after open RFA than after CT targeted RFA (P20 mm and CT-targeted RFA as independent risk factors for ASR. Conclusion. Variation in anatomical concordance between preablation and postablation images, index-tumor size, and a CT-targeted approach are risk factors for ASR in CRLM.

  17. Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Hun; Park, Jin Hong; Choi, Byung Don; Won, Hui Su; Chang, Nam Jun; Goo, Jang Hyun; Hong, Joo Wan [Dept. of Radiation Oncology, Seoul national university bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, 15x15cm{sup 2} and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

  18. Image patch-based method for automated classification and detection of focal liver lesions on CT

    Science.gov (United States)

    Safdari, Mustafa; Pasari, Raghav; Rubin, Daniel; Greenspan, Hayit

    2013-03-01

    We developed a method for automated classification and detection of liver lesions in CT images based on image patch representation and bag-of-visual-words (BoVW). BoVW analysis has been extensively used in the computer vision domain to analyze scenery images. In the current work we discuss how it can be used for liver lesion classification and detection. The methodology includes building a dictionary for a training set using local descriptors and representing a region in the image using a visual word histogram. Two tasks are described: a classification task, for lesion characterization, and a detection task in which a scan window moves across the image and is determined to be normal liver tissue or a lesion. Data: In the classification task 73 CT images of liver lesions were used, 25 images having cysts, 24 having metastasis and 24 having hemangiomas. A radiologist circumscribed the lesions, creating a region of interest (ROI), in each of the images. He then provided the diagnosis, which was established either by biopsy or clinical follow-up. Thus our data set comprises 73 images and 73 ROIs. In the detection task, a radiologist drew ROIs around each liver lesion and two regions of normal liver, for a total of 159 liver lesion ROIs and 146 normal liver ROIs. The radiologist also demarcated the liver boundary. Results: Classification results of more than 95% were obtained. In the detection task, F1 results obtained is 0.76. Recall is 84%, with precision of 73%. Results show the ability to detect lesions, regardless of shape.

  19. Paired inspiratory/expiratory volumetric CT and deformable image registration for quantitative and qualitative evaluation of airflow limitation in smokers with or without copd.

    Science.gov (United States)

    Nishio, Mizuho; Matsumoto, Sumiaki; Tsubakimoto, Maho; Nishii, Tatsuya; Koyama, Hisanobu; Ohno, Yoshiharu; Sugimura, Kazuro

    2015-03-01

    To evaluate paired inspiratory/expiratory computed tomography (CT; iCT/eCT) and deformable image registration for quantitative and qualitative assessment of airflow limitation in smokers. Paired iCT/eCT images acquired from 35 smokers (30 men and 5 women) were coregistered and subtraction images (air trapping CT images [aCT]) generated. To evaluate emphysema quantitatively, the percentage of low-attenuation volume (LAV%) on iCT was calculated at -950 HU, as were mean and kurtosis on aCT for quantitative assessment of air trapping. Parametric response maps of emphysema (PRMe) and of functional small airways disease (PRMs) were also obtained. For qualitative evaluation of emphysema, low-attenuation areas on iCT were scored by consensus of two radiologists using Goddard classification. To assess air trapping qualitatively, the degree of air trapping on aCT was scored. For each quantitative and qualitative index, the Spearman rank correlation coefficient for forced expiratory flow in 1 second was calculated, and differences in correlation coefficients were statistically tested. The correlation coefficients for the indices were as follows: mean on aCT, 0.800; kurtosis on aCT, -0.726; LAV%, -0.472; PRMe, -0.570; PRMs, -0.565; addition of PRMe and PRMs, -0.653; emphysema score, -0.502; air trapping score, -0.793. The indices showing significant differences were as follows: mean on aCT and addition of PRMe and PRMs (P = 1.43 × 10(-8)); air trapping score and emphysema score (P = .0169). Air trapping images yielded more accurate quantitative and qualitative evaluation of airflow limitation than did LAV%, PRMe, PRMs, and Goddard classification. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  20. Open source deformable image registration system for treatment planning and recurrence CT scans

    DEFF Research Database (Denmark)

    Zukauskaite, Ruta; Brink, Carsten; Hansen, Christian Rønn

    2016-01-01

    manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. METHODS: pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR...... on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p elastix in HNSCC on planning and recurrence CT scans is feasible...

  1. Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware

    Science.gov (United States)

    Kole, J. S.; Beekman, F. J.

    2006-02-01

    Statistical reconstruction methods offer possibilities to improve image quality as compared with analytical methods, but current reconstruction times prohibit routine application in clinical and micro-CT. In particular, for cone-beam x-ray CT, the use of graphics hardware has been proposed to accelerate the forward and back-projection operations, in order to reduce reconstruction times. In the past, wide application of this texture hardware mapping approach was hampered owing to limited intrinsic accuracy. Recently, however, floating point precision has become available in the latest generation commodity graphics cards. In this paper, we utilize this feature to construct a graphics hardware accelerated version of the ordered subset convex reconstruction algorithm. The aims of this paper are (i) to study the impact of using graphics hardware acceleration for statistical reconstruction on the reconstructed image accuracy and (ii) to measure the speed increase one can obtain by using graphics hardware acceleration. We compare the unaccelerated algorithm with the graphics hardware accelerated version, and for the latter we consider two different interpolation techniques. A simulation study of a micro-CT scanner with a mathematical phantom shows that at almost preserved reconstructed image accuracy, speed-ups of a factor 40 to 222 can be achieved, compared with the unaccelerated algorithm, and depending on the phantom and detector sizes. Reconstruction from physical phantom data reconfirms the usability of the accelerated algorithm for practical cases.

  2. Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware

    Energy Technology Data Exchange (ETDEWEB)

    Kole, J S; Beekman, F J [Image Sciences Institute, Department of Nuclear Medicine and Department of Pharmacology and Anatomy, Rudolf Magnus Institute of Neuroscience, UMC Utrecht, Universiteitsweg 100, STR5.203, 3584 CG Utrecht (Netherlands)

    2006-02-21

    Statistical reconstruction methods offer possibilities to improve image quality as compared with analytical methods, but current reconstruction times prohibit routine application in clinical and micro-CT. In particular, for cone-beam x-ray CT, the use of graphics hardware has been proposed to accelerate the forward and back-projection operations, in order to reduce reconstruction times. In the past, wide application of this texture hardware mapping approach was hampered owing to limited intrinsic accuracy. Recently, however, floating point precision has become available in the latest generation commodity graphics cards. In this paper, we utilize this feature to construct a graphics hardware accelerated version of the ordered subset convex reconstruction algorithm. The aims of this paper are (i) to study the impact of using graphics hardware acceleration for statistical reconstruction on the reconstructed image accuracy and (ii) to measure the speed increase one can obtain by using graphics hardware acceleration. We compare the unaccelerated algorithm with the graphics hardware accelerated version, and for the latter we consider two different interpolation techniques. A simulation study of a micro-CT scanner with a mathematical phantom shows that at almost preserved reconstructed image accuracy, speed-ups of a factor 40 to 222 can be achieved, compared with the unaccelerated algorithm, and depending on the phantom and detector sizes. Reconstruction from physical phantom data reconfirms the usability of the accelerated algorithm for practical cases.

  3. A study on quantifying COPD severity by combining pulmonary function tests and CT image analysis

    Science.gov (United States)

    Nimura, Yukitaka; Kitasaka, Takayuki; Honma, Hirotoshi; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Mori, Kensaku

    2011-03-01

    This paper describes a novel method that can evaluate chronic obstructive pulmonary disease (COPD) severity by combining measurements of pulmonary function tests and measurements obtained from CT image analysis. There is no cure for COPD. However, with regular medical care and consistent patient compliance with treatments and lifestyle changes, the symptoms of COPD can be minimized and progression of the disease can be slowed. Therefore, many diagnosis methods based on CT image analysis have been proposed for quantifying COPD. Most of diagnosis methods for COPD extract the lesions as low-attenuation areas (LAA) by thresholding and evaluate the COPD severity by calculating the LAA in the lung (LAA%). However, COPD is usually the result of a combination of two conditions, emphysema and chronic obstructive bronchitis. Therefore, the previous methods based on only LAA% do not work well. The proposed method utilizes both of information including the measurements of pulmonary function tests and the results of the chest CT image analysis to evaluate the COPD severity. In this paper, we utilize a multi-class AdaBoost to combine both of information and classify the COPD severity into five stages automatically. The experimental results revealed that the accuracy rate of the proposed method was 88.9% (resubstitution scheme) and 64.4% (leave-one-out scheme).

  4. Importance of multidetector CT imaging in multiple trauma; Stellenwert der Multidetektor-CT bei Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U. [HELIOS Kliniken Muenchen West, HELIOS Klinik Muenchen Perlach, Institut fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Geyer, L.L.; Reiser, M.; Wirth, S. [Klinikum der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Koerner, M. [Radiologie Muehleninsel, Landshut (Germany)

    2014-09-15

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [German] Die Diagnostik komplexer Mehrfachverletzungen ist eine Herausforderung fuer die moderne radiologische Notfalldiagnostik. Eine umfassend angelegte, fruehe und praezise radiologische Diagnostik ist entscheidend fuer eine prioritaetenorientierte und

  5. Correlation of the same fields imaged in the TEM, confocal, LM, and microCT by image registration: from specimen preparation to displaying a final composite image.

    Science.gov (United States)

    Keene, Douglas R; Tufa, Sara F; Wong, Melissa H; Smith, Nicholas R; Sakai, Lynn Y; Horton, William A

    2014-01-01

    Correlated imaging is the process of imaging a specimen with two complementary modalities and then registering and overlaying the fields obtained in each modality to create a composite view. One of the images is made somewhat transparent, allowing detail in the underlying image to be visible and assisting in the registration of the two images. As an example, an image localizing a specific tissue component by fluorescence may be overlaid atop a TEM image of the same field. The resulting composite image would demonstrate specific ultrastructural features in the high-resolution TEM field, which are colorized in the overlay. Other examples include composites from MicroCT or soft X-ray images overlaid atop light microscopy or TEM images. Automated image registration may be facilitated by a variety of sophisticated computer programs utilized by high-throughput laboratories. This chapter is meant for the more occasional user wishing to align images manually. ImageJ is a public domain, image processing program developed at the National Institutes of Health and is available to anyone as a free download. ImageJ performs marvelously well for the purpose of image registration; therefore, step-by-step instructions are included here. Specimen handling, including fixation and choice of embedding media, is not straightforward for correlative imaging. A step-by-step description of the protocols which work in our laboratory is included for simultaneous localization in LM, EM and micro-CT, as well as maintaining GFP emission in tissue embedded for TEM. © 2014 Elsevier Inc. All rights reserved.

  6. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Yasuyuki; Murase, Kenya [Osaka Univ., Suita (Japan). Graduate School of Medicine; Higashino, Hiroshi [Ehime Prefectural Imabari Hospital (Japan); Mochizuki, Teruhito [Ehime Univ., Matsuyama (Japan). School of Medicine; Motomura, Nobutoku [Toshiba Corp., Otawara, Tochigi (Japan). Medical Engineering Lab.

    2002-09-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with {sup 201}Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external {gamma}-ray source ({sup 99m}Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  7. Development of a guideline on reading CT images of malignant pleural mesothelioma and selection of the reference CT films

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Huashi, E-mail: zhouhua@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Tamura, Taro, E-mail: tarou@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Kusaka, Yukinori, E-mail: kusakayk@gmail.com [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Suganuma, Narufumi, E-mail: nsuganuma@kochi-u.ac.jp [Department of Environmental Medicine, Kochi University School of Medicine (Japan); Subhannachart, Ponglada, E-mail: pongladas@gmail.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Vijitsanguan, Chomphunut, E-mail: Chompoo_vj@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Noisiri, Weeraya, E-mail: weeraya_tat@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Hering, Kurt G., E-mail: k.g.hering@t-online.de [Department of Diagnostic Radiology, Radiooncology and Nuclear Medicine, Radiological Clinic, Miner' s Hospital, Radiologische Klinik, Lansppaschaftskranhaus Dortmund, Wieckesweg 27 44309, Dortmund (Germany); Akira, Masanori, E-mail: akira@kch.hosp.go.jp [Department of Radiology, National Hospital Organization Kinki-Chuo Chest Medical Center, 1180 Nagasone-cho, Kita-ku, Sakai, Osaka 591-8555 (Japan); Itoh, Harumi, E-mail: hitoh@fmsrsa.fukui-med.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Department of Radiology, School of Medicine, University of Fukui, 23-3 Shimoaitsuki Matsuoka, Eiheizi-cho, Fukui Prefecture 910-1193 (Japan); and others

    2012-12-15

    Purpose: International experts developed a guideline on reading CT images of malignant pleural mesothelioma for radiologists and physicians. It is intended that it act as a supplement to the current International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Methods: The research literatures on mesothelioma CT features were systematically reviewed. Ten mesothelioma CT features were adopted into the guideline prepared according to experts’ opinion. The terminology of mesothelioma CT features and mesothelioma probability were agreed by consensus of experts. The CT reference films for each mesothelioma feature were selected based on agreement by experts from 22 definite mesothelioma cases confirmed pathologically and immunohistochemically. To support the validity of the mesothelioma probability, 4 experts’ readings of CT films from 57 cases with or without mesothelioma were analyzed by kappa statistics between the experts; sensitivity and specificity for mesothelioma were also assessed. Results: The mesothelioma CT Guideline was developed, providing the terminology of CT features and the mesothelioma probability, the judgement of severity, the distribution of mesothelioma, and the revised CT reading sheet including mesothelioma items. The CT reference films with ten mesothelioma typical features were selected. The average linearly and quadratically weighted kappa of the agreement on the 4-point scale mesothelioma probability were 0.58 and 0.71, respectively. The average sensitivity and specificity for mesothelioma were 93.2% and 65.6%, respectively. Conclusion: The evidence-based mesothelioma CT Guideline developed may serve as a good educational tool to facilitate physicians in recognising mesothelioma and improve their proficiency in diagnosis of mesothelioma.

  8. Mirror-image lymph node in FDG PET/CT and SPECT/CT for sentinel node detection.

    Science.gov (United States)

    Domenech, Beatriz; Paredes, Pilar; Rubí, Sebastià; Pahisa, Jaume; Vidal-Sicart, Sergi; Pons, Francesca

    2014-03-01

    We report a case of a patient with presumed stage IB1 squamous cell carcinoma of the cervix in which FDG PET/CT scan revealed 1 hypermetabolic left iliac node suggestive to be malignant. Lymphoscintigraphy and SPECT/CT studies previous to sentinel node (SLN) biopsy revealed unilateral drainage in the right pelvis. Intraoperative pathological assessment of the SLN showed no tumoral involvement, and the hypermetabolic node revealed macrometastasis. Tumor node invasion can lead to a lymphatic blockage and become false-negative for SLN technique. Although FDG PET/CT has lower sensitivity than surgical staging, this case shows its value as a preoperative imaging technique.

  9. Concurrent Diffuse Pyelonephritis and Prostatitis: Discordant Findings on Sequential FDG PET/CT and 67Ga SPECT/CT Imaging.

    Science.gov (United States)

    Lucaj, Robert; Achong, Dwight M

    2017-01-01

    A 45-year-old man underwent FDG PET/CT for initial imaging evaluation of recurrent Escherichia coli urinary tract infections, which demonstrated no significant FDG uptake in either kidney and subtle FDG uptake in the right prostate lobe. Subsequent Ga SPECT/CT demonstrated abnormal intense gallium uptake throughout the right kidney and entire prostate gland, clearly discordant with PET/CT findings and consistent with unexpected concurrent pyelonephritis and prostatitis. Although FDG has effectively replaced Ga in everyday clinical practice, the current case serves as a reminder that there is still a role for Ga in the evaluation of genitourinary infections.

  10. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  11. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-H [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec.1, Jianguo N.Rd, Taichung City 40201, Taiwan (China); Liang, C-H [Agfa Healthcare Systems Taiwan Co., Ltd., 6F, 237 Sung Chiang Road, Taipei, 104 Taiwan (China); Wu, J-K [Division of Radiation Oncology, Department of Oncology, and Cancer Research Center, National Taiwan University Hospital, No.7 Chung San South Road, Taipei, 104 Taiwan (China); Lien, C-Y [Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec.2, Linong Street, Taipei, 112 Taiwan (China); Yang, B-H; Lee, J J S [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, No. 155, Sec.2, Linong Street, Taipei, 112 Taiwan (China); Huang, Y-H [Department of Medical Imaing and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao Township, Kaohsiung County 82445, Taiwan (China)], E-mail: jslee@ym.edu.tw

    2009-07-15

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT

  12. Portal dosimetry for VMAT using integrated images obtained during treatment.

    Science.gov (United States)

    Bedford, James L; Hanson, Ian M; Hansen, Vibeke Nordmark

    2014-02-01

    Portal dosimetry provides an accurate and convenient means of verifying dose delivered to the patient. A simple method for carrying out portal dosimetry for volumetric modulated arc therapy (VMAT) is described, together with phantom measurements demonstrating the validity of the approach. Portal images were predicted by projecting dose in the isocentric plane through to the portal image plane, with exponential attenuation and convolution with a double-Gaussian scatter function. Appropriate parameters for the projection were selected by fitting the calculation model to portal images measured on an iViewGT portal imager (Elekta AB, Stockholm, Sweden) for a variety of phantom thicknesses and field sizes. This model was then used to predict the portal image resulting from each control point of a VMAT arc. Finally, all these control point images were summed to predict the overall integrated portal image for the whole arc. The calculated and measured integrated portal images were compared for three lung and three esophagus plans delivered to a thorax phantom, and three prostate plans delivered to a homogeneous phantom, using a gamma index for 3% and 3 mm. A 0.6 cm(3) ionization chamber was used to verify the planned isocentric dose. The sensitivity of this method to errors in monitor units, field shaping, gantry angle, and phantom position was also evaluated by means of computer simulations. The calculation model for portal dose prediction was able to accurately compute the portal images due to simple square fields delivered to solid water phantoms. The integrated images of VMAT treatments delivered to phantoms were also correctly predicted by the method. The proportion of the images with a gamma index of less than unity was 93.7% ± 3.0% (1SD) and the difference between isocenter dose calculated by the planning system and measured by the ionization chamber was 0.8% ± 1.0%. The method was highly sensitive to errors in monitor units and field shape, but less sensitive to

  13. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    Directory of Open Access Journals (Sweden)

    Yuka Yamamoto

    2014-05-01

    diphosphonate (HMDP. Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography/ computed tomography (SPECT/CT images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone: the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis.

  14. Development of a combined microSPECT/CT system for small animal imaging

    Science.gov (United States)

    Sun, Mingshan

    Modern advances in the biomedical sciences have placed increased attention on small animals such as mice and rats as models of human biology and disease in biological research and pharmaceutical development. Their small size and fast breeding rate, their physiologic similarity to human, and, more importantly, the availability of sophisticated genetic manipulations, all have made mice and rats the laboratory mammals of choice in these experimental studies. However, the increased use of small animals in biomedical research also calls for new instruments that can measure the anatomic and metabolic information noninvasively with adequate spatial resolution and measurement sensitivity to facilitate these studies. This dissertation describes the engineering development of a combined single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) system dedicated for small animals imaging. The system aims to obtain both the anatomic and metabolic images with submillimeter spatial resolution in a way that the data can be correlated to provide improved image quality and to offer more complete biological evaluation for biomedical studies involving small animals. The project requires development of complete microSPECT and microCT subsystems. Both subsystems are configured with a shared gantry and animal bed with integrated instrumentation for data acquisition and system control. The microCT employs a microfocus X-ray tube and a CCD-based detector for low noise, high resolution imaging. The microSPECT utilizes three semiconductor detectors coupled with pinhole collimators. A significant contribution of this dissertation project is the development of iterative algorithms with geometrical compensation that allows radionuclide images to be reconstructed at submillimeter spatial resolution, but with significantly higher detection efficiency than conventional methods. Both subsystems are capable of helical scans, offering lengthened field of view and improved

  15. Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: Initial patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Apfaltrer, Paul, E-mail: paul.apfaltrer@medma.uni-heidelberg.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoendube, Harald, E-mail: harald.schoendube@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Allmendinger, Thomas, E-mail: thomas.allmendinger@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Tricarico, Francesco, E-mail: francescotricarico82@gmail.com [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, “A. Gemelli” Hospital, Largo A. Gemelli 8, Rome (Italy); Schindler, Andreas, E-mail: andreas.schindler@campus.lmu.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Vogt, Sebastian, E-mail: sebastian.vogt@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Sunnegårdh, Johan, E-mail: johan.sunnegardh@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); and others

    2013-02-15

    Objective: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. Materials and methods: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175–426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. Results: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m{sup 2}. Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p > 0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p > 0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p < 0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median = 2.5) and TRIM (median = 2.0) reconstructions. Conclusion: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients.

  16. A LabVIEW based user-friendly nano-CT image alignment and 3D reconstruction platform

    CERN Document Server

    Wang, Shenghao; Wang, Zhili; Gao, Kun; Wu, Zhao; Zhu, Peiping; Wu, Ziyu

    2014-01-01

    X-ray nanometer computed tomography (nano-CT) offers applications and opportunities in many scientific researches and industrial areas. Here we present a user-friendly and fast LabVIEW based package running, after acquisition of the raw projection images, a procedure to obtain the inner structure of the sample under analysis. At first, a reliable image alignment procedure fixes possible misalignments among image series due to mechanical errors, thermal expansion and other external contributions, then a novel fast parallel beam 3D reconstruction performs the tomographic reconstruction. The remarkable improved reconstruction after the image calibration confirms the fundamental role of the image alignment procedure. It minimizes blurring and additional streaking artifacts present in a reconstructed slice that cause loss of information and faked structures in the observed material. The nano-CT image alignment and 3D reconstruction LabVIEW package significantly reducing the data process, makes faster and easier th...

  17. CT venography for deep venous thrombosis: continuous images versus reformatted discontinuous images using PIOPED II data.

    Science.gov (United States)

    Goodman, Lawrence R; Stein, Paul D; Beemath, Afzal; Sostman, H Dirk; Wakefield, Thomas W; Woodard, Pamela K; Yankelevitz, David F

    2007-08-01

    This study was designed to determine whether discontinuous CT of the lower extremities for the detection of deep venous thrombosis (DVT) yields results similar to those of complete helical imaging using cases from the Prospective Investigation of Pulmonary Embolism Diagnosis II (PIOPED II). In PIOPED II, CT venography followed CT angiography (CTA) to detect pulmonary embolus, using 7.5-mm continuous helical imaging from the iliac crest to the tibial plateau. DVT was detected in 105 of 737 patients (14.2%). We randomly chose 54 positive cases and 96 negative cases for our study. The continuous helical images were reformatted as 7.5-mm images and two of every three images were deleted. These images (7.5 mm; skip = 15 mm) were then sent--without identifying information--to the original reviewers. From 1 to 3.5 years had elapsed since the original interpretations. The results of the new interpretations were compared with the original CT venography consensus interpretations of PIOPED II. There was agreement for the presence of DVT in at least one leg (same leg) or for the absence of DVT in both legs in 133 of the 150 study patients (89%). The kappa statistic showed substantial agreement between the consensus interpretations and the test interpretations (kappa = 0.75; 95% CI = 0.64-0.86) per patient. There was good--but not perfect--agreement between continuous helical and discontinuous axial imaging for the detection of DVT. Given the vagaries of interobserver and intraobserver variation, there appears to be little difference between the two approaches. Adopting discontinuous imaging and other dose-reduction strategies can reduce pelvic radiation by more than 75%.

  18. CT imaging of the internal human ear: Test of a high resolution scanner

    Energy Technology Data Exchange (ETDEWEB)

    Bettuzzi, M., E-mail: matteo.bettuzzi@unibo.it [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Brancaccio, R.; Morigi, M.P. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Gallo, A. [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Strolin, S.; Casali, F. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Lamanna, Ernesto [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Ariu, Marilu [CEFLA Dental Group, Imola (Italy)

    2011-08-21

    During the course of 2009, in the framework of a project supported by the National Institute of Nuclear Physics, a number of tests were carried out at the Department of Physics of the University of Bologna in order to achieve a good quality CT scan of the internal human ear. The work was carried out in collaboration with the local 'S. Orsola' Hospital in Bologna and a company (CEFLA) already involved in the production and commercialization of a CT scanner dedicated to dentistry. A laboratory scanner with a simple concept detector (CCD camera-lens-mirror-scintillator) was used to see to what extent it was possible to enhance the quality of a conventional CT scanner when examining the internal human ear. To test the system, some conventional measurements were made, such as the spatial resolution calculation with the MTF and dynamic range evaluation. Different scintillators were compared to select the most suitable for the purpose. With 0.5 mm thick structured cesium iodide and a field of view of 120x120 mm{sup 2}, a spatial resolution of 6.5l p/mm at 5% MTF was obtained. The CT of a pair of human head phantoms was performed at an energy of 120 kVp. The first phantom was a rough representation of the human head shape, with soft tissue made of coarse slabs of Lucite. Some inserts, like small aluminum cylinders and cubes, with 1 mm diameter drilled holes, were used to simulate the channels that one finds inside the human inner ear. The second phantom is a plastic PVC fused head with a real human cranium inside. The bones in the cranium are well conserved and the inner ear features, such as the cochlea and semicircular channels, are clearly detectable. After a number of CT tests we obtained good results as far as structural representation and channel detection are concerned. Some images of the 3D rendering of the CT volume are shown below. The doctors of the local hospital who followed our experimentation expressed their satisfaction. The CT was compared to a

  19. Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

    Science.gov (United States)

    Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko

    2015-06-01

    Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P computation time despite the difference in the complexity of the algorithms (P = .71). The GPU-accelerated volume subdivision technique was as accurate as the B-spline technique and required significantly less processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid

  20. Physiological study on CT image analysis of acute pulmonary edema by oleic acid and its application to diagnosis of drowning

    Energy Technology Data Exchange (ETDEWEB)

    Nosaka, Mizuho [Wakayama Medical Coll. (Japan)

    1998-05-01

    Recently, various investigations are carried out about the relationship between the pathophysiological changes and the images of the destructive extent in acute lung injury. In present paper, we examined, in progression time, the pathophysiological and histological changes basing upon pulmonary edema model made by administration of oleic acid to beagle dogs, and simultaneously took images of the lung by employing high-resolution X-ray CT and analyzed them. In pathophysiological and histological investigation, V{sub A}/Q heterogeneity and lung water volume increased, and decrease of PO{sub 2} in arterial blood was observed, and also filling of the alveoli with exudate, edema of the alveolar interstitium, congestion of the alveoli were observed histologically. In image analysis, the findings, that is enough to reflect the pathophysiological and histological changes, were obtained from mean CT value and the distribution of CT value histogram. Moreover, the same examination as in acute pulmonary edema model was carried out in drowning model with seawater. Consequently, it became evident that presuming of pathophysiological changes in drowning was possible from results of X-ray CT image analysis. The results described above seem to indicate that X-ray CT image analysis in acute lung injury can use as an index of the damage degree, and also is available for elucidation of the pathophysiological changes. (author)

  1. Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

    Energy Technology Data Exchange (ETDEWEB)

    Tang Xiangyang; Yang Yi; Tang Shaojie [Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Drive, C-5018, Atlanta, Georgia 30322 (United States)

    2012-07-15

    Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function

  2. Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2012-01-01

    Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360° full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G1 and G2 with periods 8 and 4 μm, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 × 32, 64 × 64, 96 × 96, and 128 × 128 μm2, respectively, corresponding to a 40.96 × 40.96 mm2 field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n = 1 − δ + iβ = 1 −2.5604 × 10−7 + i1.2353 × 10−10 is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 × 106 photon/cm2 per projection and

  3. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  4. Anatomy packing with hierarchical segments: an algorithm for segmentation of pulmonary nodules in CT images.

    Science.gov (United States)

    Tsou, Chi-Hsuan; Lor, Kuo-Lung; Chang, Yeun-Chung; Chen, Chung-Ming

    2015-05-14

    This paper proposes a semantic segmentation algorithm that provides the spatial distribution patterns of pulmonary ground-glass nodules with solid portions in computed tomography (CT) images. The proposed segmentation algorithm, anatomy packing with hierarchical segments (APHS), performs pulmonary nodule segmentation and quantification in CT images. In particular, the APHS algorithm consists of two essential processes: hierarchical segmentation tree construction and anatomy packing. It constructs the hierarchical segmentation tree based on region attributes and local contour cues along the region boundaries. Each node of the tree corresponds to the soft boundary associated with a family of nested segmentations through different scales applied by a hierarchical segmentation operator that is used to decompose the image in a structurally coherent manner. The anatomy packing process detects and localizes individual object instances by optimizing a hierarchical conditional random field model. Ninety-two histopathologically confirmed pulmonary nodules were used to evaluate the performance of the proposed APHS algorithm. Further, a comparative study was conducted with two conventional multi-label image segmentation algorithms based on four assessment metrics: the modified Williams index, percentage statistic, overlapping ratio, and difference ratio. Under the same framework, the proposed APHS algorithm was applied to two clinical applications: multi-label segmentation of nodules with a solid portion and surrounding tissues and pulmonary nodule segmentation. The results obtained indicate that the APHS-generated boundaries are comparable to manual delineations with a modified Williams index of 1.013. Further, the resulting segmentation of the APHS algorithm is also better than that achieved by two conventional multi-label image segmentation algorithms. The proposed two-level hierarchical segmentation algorithm effectively labelled the pulmonary nodule and its surrounding

  5. Sinusitis and intracranial sepsis: the CT imaging and clinical presentation

    Energy Technology Data Exchange (ETDEWEB)

    Saxton, V.J. [Dept. of Radiology, Royal Children`s Hospital, Melbourne (Australia); Boldt, D.W. [Dept. of Radiology, Royal Children`s Hospital, Melbourne (Australia); Shield, L.K. [Dept. of Neurology, Royal Children`s Hospital, Melbourne (Australia)

    1995-11-01

    The CT imaging and clinical presentation in 14 children with coexistent intracranial sepsis and sinusitis were reviewed. A routine CT head scan (10-mm thick semi-axial slices through the cranium done before and after intravenous contrast medium administration) was found to be an inadequate initial investigation as the intracranial collection was missed in four patients and the abnormal sinuses not shown in six. In half the children the dagnosis of sinusitis was unsuspected at the time of admission. The dominant clinical features were fever, intense headache and facial swelling in early adolescent males. In this clinical setting we recommend: (1) The routine scan is extended through the frontal and ethmoidal sinuses and photographed at a window level and width showing both bone detail and air/soft tissue interfaces; (2) direct coronal projections are performed through the anterior cranial fossa if no collection is seen on the routine study; (3) an early repeat scan within 48 h if the initial study shows no intracranial pathology but the fronto-ethomoidal sinuses are abnormal and there is a high clinical supicion of intracranial sepsis; and (4) in the presence of intracranial sepsis the vault is viewed at bone window settings to exclude cranial osteomyelitis. (orig.)

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... and accurate. It’s also the most reliable imaging technique for determining if the sinuses are obstructed and ... to obtain images. For children, the CT scanner technique will be adjusted to their size and the ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... to obtain images. For children, the CT scanner technique will be adjusted to their size and the ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  8. The cerebral imaging using vessel-around method in the perfusion CT of the human brain

    Science.gov (United States)

    Ahn, Choong-Il; Choi, Seung-Wook; Park, Seung-Chul; Shin, Yeong-Gil; Kim, Jae-Hyoung; Chong, Gi-Bong

    2005-04-01

    Perfusion CT has been successfully used as a functional imaging technique for diagnosis of patients with hyperacute stroke. However, the commonly used methods based on curve-fitting are time consuming. Numerous researchers have investigated to what extent Perfusion CT can be used for the quantitative assessment of cerebral ischemia and to rapidly obtain comprehensive information regarding the extent of ischemic damage in acute stroke patients. The aim of this study is to propose an alternative approach to rapidly obtain the brain perfusion mapping and to show the proposed cerebral flow imaging of the vessel and tissue in human brain be reliable and useful. Our main design concern was algorithmic speed, robustness and automation in order to allow its potential use in the emergency situation of acute stroke. To obtain a more effective mapping, we analyzed the signal characteristics of Perfusion CT and defined the vessel-around model which includes the vessel and tissue. We proposed a nonparametric vessel-around approach which automatically discriminates the vessel and tissue around vessel from non-interested brain matter stratifying the level of maximum enhancement of pixel-based TAC. The stratification of pixel-based TAC was executed using the mean and standard deviation of the signal intensity of each pixel and mapped to the cerebral flow imaging. The defined vessel-around model was used to show the cerebral flow imaging and to specify the area of markedly reduced perfusion with loss of function of still viable neurons. Perfusion CT is a fast and practical technique for routine clinical application. It provides substantial and important additional information for the selection of the optimal treatment strategy for patients with hyperacute stroke. The vessel-around approach reduces the computation time significantly when compared with the perfusion imaging using the GVF. The proposed cerebral imaging shows reliable results which are validated by physicians and

  9. An evaluation on CT image acquisition method for medical VR applications

    Science.gov (United States)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  10. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weidong, E-mail: dongw.z@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Li Chuanxing, E-mail: lichuanh@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Liu Qingyu, E-mail: liu.qingyu@163.com [Department of Radiology, No. 2 Affiliated Hospital, 107 Yanjiangxi Road, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Hu Yingying, E-mail: yingyinghu1981@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Cao Yun, E-mail: caoyun@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Pathology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Huang Jinhua, E-mail: drhuangjh@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China)

    2011-11-15

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  11. Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing

    Science.gov (United States)

    Chen, Yang; Yin, Xindao; Shi, Luyao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis; Toumoulin, Christine

    2013-08-01

    In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors.

  12. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  13. Pulmonary Vascular Tree Segmentation from Contrast-Enhanced CT Images

    CERN Document Server

    Helmberger, M; Pienn, M; Balint, Z; Olschewski, A; Bischof, H

    2013-01-01

    We present a pulmonary vessel segmentation algorithm, which is fast, fully automatic and robust. It uses a coarse segmentation of the airway tree and a left and right lung labeled volume to restrict a vessel enhancement filter, based on an offset medialness function, to the lungs. We show the application of our algorithm on contrast-enhanced CT images, where we derive a clinical parameter to detect pulmonary hypertension (PH) in patients. Results on a dataset of 24 patients show that quantitative indices derived from the segmentation are applicable to distinguish patients with and without PH. Further work-in-progress results are shown on the VESSEL12 challenge dataset, which is composed of non-contrast-enhanced scans, where we range in the midfield of participating contestants.

  14. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    Directory of Open Access Journals (Sweden)

    Daniela Muenzel

    Full Text Available OBJECTIVE: To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI by using motion compensation and a spatio-temporal filter. METHODS: Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT. Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved. Three datasets for each patient were generated: (i original data (ii motion compensated data and (iii motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. RESULTS: The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. CONCLUSION: The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  15. Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vrigneaud, Jean-Marc; Courteau, Alan; Oudot, Alexandra; Collin, Bertrand [Department of Nuclear Medicine, Centre Georges-François Leclerc, 1 rue Professeur Marion, Dijon 21079 Cedex (France); Ranouil, Julien [Landauer Europe, 33 avenue du Général Leclerc, Fontenay-aux-Roses 92266 Cedex (France); Morgand, Loïc; Raguin, Olivier [Oncodesign, 20 rue Jean Mazen, Dijon 21076 Cedex (France); Walker, Paul [LE2i CNRS UMR 5158, Faculty of Medicine, BP 87900, 21079 Dijon Cedex (France); Brunotte, François [Department of Nuclear Medicine, Centre Georges-François Leclerc, 1 rue Professeur Marion, Dijon 21079 Cedex, France and LE2i CNRS UMR 5158, Faculty of Medicine, BP 87900, 21079 Dijon Cedex (France)

    2013-12-15

    Purpose: Micro-CT is considered to be a powerful tool to investigate various models of disease on anesthetized animals. In longitudinal studies, the radiation dose delivered by the micro-CT to the same animal is a major concern as it could potentially induce spurious effects in experimental results. Optically stimulated luminescence dosimeters (OSLDs) are a relatively new kind of detector used in radiation dosimetry for medical applications. The aim of this work was to assess the dose delivered by the CT component of a micro-SPECT (single-photon emission computed tomography)/CT camera during a typical whole-body mouse study, using commercially available OSLDs based on Al{sub 2}O{sub 3}:C crystals.Methods: CTDI (computed tomography dose index) was measured in micro-CT with a properly calibrated pencil ionization chamber using a rat-like phantom (60 mm in diameter) and a mouse-like phantom (30 mm in diameter). OSLDs were checked for reproducibility and linearity in the range of doses delivered by the micro-CT. Dose measurements obtained with OSLDs were compared to those of the ionization chamber to correct for the radiation quality dependence of OSLDs in the low-kV range. Doses to tissue were then investigated in phantoms and cadavers. A 30 mm diameter phantom, specifically designed to insert OSLDs, was used to assess radiation dose over a typical whole-body mouse imaging study. Eighteen healthy female BALB/c mice weighing 27.1 ± 0.8 g (1 SD) were euthanized for small animal measurements. OLSDs were placed externally or implanted internally in nine different locations by an experienced animal technician. Five commonly used micro-CT protocols were investigated.Results: CTDI measurements were between 78.0 ± 2.1 and 110.7 ± 3.0 mGy for the rat-like phantom and between 169.3 ± 4.6 and 203.6 ± 5.5 mGy for the mouse-like phantom. On average, the displayed CTDI at the operator console was underestimated by 1.19 for the rat-like phantom and 2.36 for the mouse

  16. Accessory cardiac bronchus: Proposed imaging classification on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Min; Kim, Young Tong; Han, Jong Kyu; Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of)

    2016-02-15

    To propose the classification of accessory cardiac bronchus (ACB) based on imaging using multidetector computed tomography (MDCT), and evaluate follow-up changes of ACB. This study included 58 patients diagnosed as ACB since 9 years, using MDCT. We analyzed the types, division locations and division directions of ACB, and also evaluated changes on follow-up. We identified two main types of ACB: blind-end (51.7%) and lobule (48.3%). The blind-end ACB was further classified into three subtypes: blunt (70%), pointy (23.3%) and saccular (6.7%). The lobule ACB was also further classified into three subtypes: complete (46.4%), incomplete (28.6%) and rudimentary (25%). Division location to the upper half bronchus intermedius (79.3%) and medial direction (60.3%) were the most common in all patients. The difference in division direction was statistically significant between the blind-end and lobule types (p = 0.019). Peribronchial soft tissue was found in five cases. One calcification case was identified in the lobule type. During follow-up, ACB had disappeared in two cases of the blind-end type and in one case of the rudimentary subtype. The proposed classification of ACB based on imaging, and the follow-up CT, helped us to understand the various imaging features of ACB.

  17. Automated Segmentation and Retrieval System for CT Head Images

    Science.gov (United States)

    Tong, Hau-Lee; Ahmad Fauzi, Mohammad Faizal; Komiya, Ryoichi

    In this paper, automatic segmentation and retrieval of medical images are presented. For the segmentation, different unsupervised clustering techniques are employed to partition the Computed Tomography (CT) brain images into three regions, which are the abnormalities, cerebrospinal fluids (CSF) and brain matters. The novel segmentation method proposed is a dual level segmentation approach. The first level segmentation, which purpose is to acquire abnormal regions, uses the combination of fuzzy c-means (FCM) and k-means clustering. The second level segmentation performs either the expectation-maximization (EM) technique or the modified FCM with population-diameter independent (PDI) to segment the remaining intracranial area into CSF and brain matters. The system automatically determines which algorithm to be utilized in order to produce optimum results. The retrieval of the medical images is based on keywords such as "no abnormal region", "abnormal region(s) adjacent to the skull" and "abnormal region(s) not adjacent to the skull". Medical data from collaborating hospital are experimented and promising results are observed.

  18. CT imaging of splenic sequestration in sickle cell disease

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, S.; Piomelli, S. [Columbia Univ., New York, NY (United States). Dept. of Pediatrics; Ruzal-Shapiro, C.; Berdon, W.E. [Columbia Univ., New York, NY (United States). Div. of Pediatric Radiology

    2000-12-01

    Pooling of blood in the spleen is a frequent occurrence in children with sickle cell diseases, particularly in the first few years of life, resulting in what is termed ''splenic sequestration crisis.'' The spectrum of severity in this syndrome is wide, ranging from mild splenomegaly to massive enlargement, circulatory collapse, and even death. The diagnosis is usually clinical, based on the enlargement of the spleen with a drop in hemoglobin level by >2 g/dl, and it is rare that imaging studies are ordered. However, in the patient who presents to the emergency department with non-specific findings of an acute abdomen, it is important to recognize the appearance of sequestration on imaging studies. We studied seven patients utilizing contrast-enhanced CT scans and found two distinct patterns - multiple, peripheral, non-enhancing low-density areas or large, diffuse areas of low density in the majority of the splenic tissue. Although radiological imaging is not always necessary to diagnose splenic sequestration, in those situations where this diagnosis is not immediately obvious, it makes an important clarifying contribution. (orig.)

  19. CT imaging, then and now: a 30-year review of the economics of computed tomography.

    Science.gov (United States)

    Stockburger, Wayne T

    2004-01-01

    The first computed tomography (CT) scanner in the US was installed in June 1973 at the Mayo Clinic in Rochester, MN. By the end of 1974, 44 similar systems had been installed at medical facilities around the country. Less than 4 years after the introduction of CT imaging in the US, at least 400 CT systems had been installed. The practice of pneumoencephalography was eliminated. The use of nuclear medicine brain scans significantly diminished. At the time, CT imaging was limited to head studies, but with the introduction of contrast agents and full body CT systems the changes in the practice of medicine became even more significant. CT imaging was hailed by the US medical community as the greatest advance in radiology since the discovery of x-rays. But the rapid spread of CT systems, their frequency of use, and the associated increase in healthcare costs combined to draw the attention of decision-makers within the federal and state governments, specifically to establish policies regarding the acquisition and use of diagnostic technologies. Initially, CT imaging was limited to neurological applications, but in the 30 years since its inception, capabilities and applications have been expanded as a result of the advancements in technology and software development. While neurological disorders are still a common reason for CT imaging, many other medical disciplines (oncology, emergency medicine, orthopedics, etc.) have found CT imaging to be the definitive tool for diagnostic information. As such, the clinical demand for CT imaging has steadily increased. Economically, the development of CT imaging has been one of success, even in the face of governmental action to restrict its acquisition and utilization by healthcare facilities. CTimaging has increased the cost of healthcare, but in turn has added unquantifiable value to the practice of medicine in the US.

  20. Spectral CT in patients with small HCC: investigation of image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Gao, Jianbo [The First Affiliated Hospital of Zhengzhou University, The Department of Radiology, Zhengzhou, Henan Province (China); Lin, Xiao Zhu; Chen, Kemin [Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai (China)

    2012-10-15

    To assess image quality and diagnostic accuracy of monochromatic imaging from spectral CT in patients with small HCC ({<=}3 cm). Twenty-seven patients with 31 HCC underwent spectral CT to generate conventional 140-kVp polychromatic images (group A) and monochromatic images with energy levels from 40 to 140 keV (group B) during the late arterial phase (LAP) and the portal venous phase (PVP). Two-sample t tests compared the tumour-to-liver contrast-to-noise ratio (CNR) and mean image noise. Lesion detection for LAP, reader confidence and readers' subjective evaluations of image quality were recorded. Highest CNRs in group B were distributed at 40, 50 and 70 keV. Higher CNR values and lesion conspicuity scores (LCS) were obtained in group B than in group A (CNR 3.36 {+-} 2.07 vs. 1.47 {+-} 0.89 in LAP; 2.29 {+-} 2.26 vs. 1.58 {+-} 1.75 in PVP; LCS 2.82, 2.84, 2.63 and 2.53 at 40-70 keV, respectively, vs. 1.95) (P < 0.001). Lowest image noise for group B was at 70 keV, resulting in higher image quality than that in group A (4.70 vs. 4.07; P < 0.001). Monochromatic energy levels of 40-70 keV can increase detectability in small HCC and this increase might not result in image quality degradation. (orig.)

  1. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Don; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of); Yoo, Sun Kook; Lee, Kyoung Sang [Dept. of Medical Engineering, College of Medicine, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  2. Impact of low-energy CT imaging on selection of positive oral contrast media concentration.

    Science.gov (United States)

    Patino, Manuel; Murcia, Diana J; Iamurri, Andrea Prochowski; Kambadakone, Avinash R; Hahn, Peter F; Sahani, Dushyant V

    2017-05-01

    To determine to what extent low-energy CT imaging affects attenuation of gastrointestinal tract (GIT) opacified with positive oral contrast media (OCM). Second, to establish optimal OCM concentrations for low-energy diagnostic CT exams. One hundred patients (38 men and 62 women; age 62 ± 11 years; BMI 26 ± 5) with positive OCM-enhanced 120-kVp single-energy CT (SECT), and follow-up 100-kVp acquisitions (group A; n = 50), or 40-70-keV reconstructions from rapid kV switching-single-source dual-energy CT (ssDECT) (group B; n = 50) were included. Luminal attenuation from different GIT segments was compared between exams. Standard dose of three OCM and diluted solutions (75%, 50%, and 25% concentrations) were introduced serially in a gastrointestinal phantom and scanned using SECT (120, 100, and 80 kVp) and DECT (80/140 kVp) acquisitions on a ssDECT scanner. Luminal attenuation was obtained on SECT and DECT images (40-70 keV), and compared to 120-kVp scans with standard OCM concentrations. Luminal attenuation was higher on 100-kVp (328 HU) and on 40-60-keV images (410-924 HU) in comparison to 120-kVp scans (298 HU) in groups A and B (p concentration.

  3. Ultra-low dose comprehensive cardiac CT imaging in a patient with acute myocarditis.

    Science.gov (United States)

    Tröbs, Monique; Brand, Michael; Achenbach, Stephan; Marwan, Mohamed

    2014-01-01

    The ability of contrast-enhanced CT to detect "late enhancement" in a fashion similar to magnetic resonance imaging has been previously reported. We report a case of acute myocarditis with coronary CT angiography as well as "late enhancement" imaging with ultra-low effective radiation dose.

  4. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre and Caen University, Bioticla Team, EA1792, IFR 146 ICORE, GRECAN, Caen (France); Caen University Hospital and Francois Baclesse Cancer Centre, PET Unit, Caen (France); Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia); Centre Francois Baclesse, Nuclear Medicine Department, Caen cedex 5 (France); Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard [Caen University Hospital and Francois Baclesse Cancer Centre, PET Unit, Caen (France); Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia); Beyer, Thomas [cmi-experts GmbH, Zurich (Switzerland); University Hospital Essen, Department of Nuclear Medicine, Essen (Germany); University Hospital Bern, Institute of Nuclear Medicine, Bern (Switzerland); Kinross, Kathryn [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia); Peter MacCallum Cancer Centre, Sir Donald and Lady Trescowthick Laboratories, East Melbourne (Australia); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia); University of Melbourne, The Department of Medicine, Parkville (Australia)

    2010-05-15

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of {sup 68}Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR{sub air} and SOR{sub water} were 5.3 and 7.5%, respectively. A strong correlation (r {sup 2} = 0.97, p < 0.0001) between quantitative data obtained in mice imaged alone and simultaneously in a group of three was found following PSF reconstruction. The correlation between ex vivo counting and PET/CT data was better with PSF reconstruction (r {sup 2} = 0.98; slope = 0.89, p < 0.0001) than without (r {sup 2} = 0.96; slope = 0.62, p < 0.001). Valid time-activity curves of the blood pool, kidneys and bladder could be derived from {sup 68}Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  5. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    Science.gov (United States)

    Slot Thing, Rune; Bernchou, Uffe; Mainegra-Hing, Ernesto; Hansen, Olfred; Brink, Carsten

    2016-08-01

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five lung cancer patients. Projection image based artefact corrections of image lag, detector scatter, body scatter and beam hardening are described and applied to CBCT images of five lung cancer patients. Image quality is evaluated through visual appearance of the reconstructed images, HU-correspondence with the planning CT images, and total volume HU error. Artefacts are reduced and CT-like HUs are recovered in the artefact corrected CBCT images. Visual inspection confirms that artefacts are indeed suppressed by the proposed method, and the HU root mean square difference between reconstructed CBCTs and the reference CT images are reduced by 31% when using the artefact corrections compared to the standard clinical CBCT reconstruction. A versatile artefact correction method for clinical CBCT images acquired for IGRT has been developed. HU values are recovered in the corrected CBCT images. The proposed method relies on post processing of clinical projection images, and does not require patient specific optimisation. It is thus a powerful tool for image quality improvement of large numbers of CBCT images.

  6. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  7. Dose efficiency consideration for volume-of-interest breast imaging using x-ray differential phase-contrast CT

    Science.gov (United States)

    Cai, Weixing; Ning, Ruola

    2009-02-01

    The newly developed differential phase-contrast (DPC) imaging technique has attracted increasing interest among researchers. In a DPC system, the self-imaging effect and the phase-stepping method are implemented through three gratings to manifest phase contrast, and differentiated phase images can be obtained. An important advantage of this technique is that hospital-grade x-ray tubes can be used, allowing much higher x-ray output power and faster image processing than with micro-focus in-line phase-contrast imaging. A DPC-CT system can acquire images from different view angles along a circular orbit, and tomographic images can be reconstructed. However, the principle of DPC imaging requires multiple exposures to compute any differentiated phase image at each view angle, which raises concerns about radiation exposure via x-ray dose. Computer simulations are carried out to study the dose efficiency for DPC-CT for volume-of-interest breast imaging. A conceptual CBCT/DPC-CT hybrid imaging system and a numerical breast phantom are designed for this study. A FBP-type reconstruction algorithm is optimized for the VOI reconstruction. Factors including the x-ray flux and detector pixel size are considered and their effects on reconstruction image quality in terms of noise level and contrast-to-noise ratio are investigated. The results indicate that with a pixel size of 20 microns and a dose level of 5.7mGy, which is equivalent to the patient dose of a two-view mammography screening or a dedicated CBCT breast imaging scan, much better tissue contrast and spatial resolution can be achieved using the DPC-CT technique. It is very promising for possible application at pathology-level in vivo study for human breasts.

  8. Technological value of SPECT/CT fusion imaging for the diagnosis of lower gastrointestinal bleeding.

    Science.gov (United States)

    Wang, Z G; Zhang, G X; Hao, S H; Zhang, W W; Zhang, T; Zhang, Z P; Wu, R X

    2015-11-24

    The aim of this study was to assess the clinical value of diagnosing and locating lower gastrointestinal (GI) bleeding using single photon emission computed tomography (SPECT)/computed tomography (CT) fusion imaging with 99mTc labeled red blood cells ((99m)Tc-RBC). Fifty-six patients with suspected lower GI bleeding received a preoperative intravenous injection of (99m)Tc-RBC and each underwent planar, SPECT/CT imaging of the lower abdominal region. The location and path of lower GI bleeding were diagnosed by contrastive analysis of planar and SPECT/CT fusion imaging. Among the 56 patients selected, there were abnormalities in concentrated radionuclide activity with planar imaging in 50 patients and in SPECT/CT fusion imaging in 52 patients. Moreover, bleeding points that were coincident with the surgical results were evident with planar imaging in 31 patients and with SPECT/CT fusion imaging in 48 patients. The diagnostic sensitivity of planar imaging and SPECT/CT fusion imaging were 89.3% (50/56) and 92.9% (52/56), respectively, and the difference was not statistically significant (χ(2) = 0.11, P > 0.05). The corresponding positional accuracy values were 73.8% (31/42) and 92.3% (48/52), and the difference was statistically significant (χ(2) = 4.63, P CT fusion imaging is an effective, simple, and accurate method that can be used for diagnosing and locating lower GI bleeding.

  9. Virtual animation of victim-specific 3D models obtained from CT scans for forensic reconstructions

    DEFF Research Database (Denmark)

    Villa, C; Olsen, K B; Hansen, S H

    2017-01-01

    the anatomical proportions of the patient was made combining the actual bones of the victim with those obtained from the human anatomy 3D model. The resulted 3D model was used for the animation process. Several probable postures were also visualized in this case. It has be shown that in Case #1 the lesions...... and the bullet path were not consistent with an upright standing position; instead, the victim was slightly bent forward, i.e. he was sitting or running when he was shot. In Case #2, one of the bullets could have passed through the arm and continued into the thorax. In conclusion, specialized 3D modelling...

  10. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  11. Reference-free ground truth metric for metal artifact evaluation in CT images

    Energy Technology Data Exchange (ETDEWEB)

    Kratz, Baerbel; Ens, Svitlana; Mueller, Jan; Buzug, Thorsten M. [Institute of Medical Engineering, University of Luebeck, 23538 Luebeck (Germany)

    2011-07-15

    Purpose: In computed tomography (CT), metal objects in the region of interest introduce data inconsistencies during acquisition. Reconstructing these data results in an image with star shaped artifacts induced by the metal inconsistencies. To enhance image quality, the influence of the metal objects can be reduced by different metal artifact reduction (MAR) strategies. For an adequate evaluation of new MAR approaches a ground truth reference data set is needed. In technical evaluations, where phantoms can be measured with and without metal inserts, ground truth data can easily be obtained by a second reference data acquisition. Obviously, this is not possible for clinical data. Here, an alternative evaluation method is presented without the need of an additionally acquired reference data set. Methods: The proposed metric is based on an inherent ground truth for metal artifacts as well as MAR methods comparison, where no reference information in terms of a second acquisition is needed. The method is based on the forward projection of a reconstructed image, which is compared to the actually measured projection data. Results: The new evaluation technique is performed on phantom and on clinical CT data with and without MAR. The metric results are then compared with methods using a reference data set as well as an expert-based classification. It is shown that the new approach is an adequate quantification technique for artifact strength in reconstructed metal or MAR CT images. Conclusions: The presented method works solely on the original projection data itself, which yields some advantages compared to distance measures in image domain using two data sets. Beside this, no parameters have to be manually chosen. The new metric is a useful evaluation alternative when no reference data are available.

  12. The Experimental Research on the Frameless Registration of DSA/CT Images

    Institute of Scientific and Technical Information of China (English)

    HUANG Yong-feng; LI Wen; ZENG Pei-feng; ZHAO Jun

    2006-01-01

    DSA images show vessels with clarity and CT images show bones distinctly. In this paper, we present an experimental research on the frameless registration of DSA/CT images based on localization algorithm. With four external markers, the vessels and bones in human brain can be integrated. The mean accuracy of simulated experiment is about 2.0 mm. The experiment proved that the 3D images composed cerebral anatomy and vasculature could help neurosurgeons perform accurate diagnosis and make right operation planning.

  13. Image enhancement by spatial frequency post-processing of images obtained with pupil filters

    Science.gov (United States)

    Estévez, Irene; Escalera, Juan C.; Stefano, Quimey Pears; Iemmi, Claudio; Ledesma, Silvia; Yzuel, María J.; Campos, Juan

    2016-12-01

    The use of apodizing or superresolving filters improves the performance of an optical system in different frequency bands. This improvement can be seen as an increase in the OTF value compared to the OTF for the clear aperture. In this paper we propose a method to enhance the contrast of an image in both its low and its high frequencies. The method is based on the generation of a synthetic Optical Transfer Function, by multiplexing the OTFs given by the use of different non-uniform transmission filters on the pupil. We propose to capture three images, one obtained with a clear pupil, one obtained with an apodizing filter that enhances the low frequencies and another one taken with a superresolving filter that improves the high frequencies. In the Fourier domain the three spectra are combined by using smoothed passband filters, and then the inverse transform is performed. We show that we can create an enhanced image better than the image obtained with the clear aperture. To evaluate the performance of the method, bar tests (sinusoidal tests) with different frequency content are used. The results show that a contrast improvement in the high and low frequencies is obtained.

  14. Accuracy assessment of the axial images obtained from cone beam computed tomography

    Science.gov (United States)

    Panzarella, FK; Junqueira, JLC; Oliveira, LB; de Araújo, NS; Costa, C

    2011-01-01

    Objective The aim of this study was to evaluate accuracy of linear measurements assessed from axial tomograms and the influence of the use of different protocols in two cone beam CT (CBCT) units. Methods A cylinder object consisting of Nylon® (Day Brazil, Sao Paulo, Brazil) with radiopaque markers was radiographically examined applying different protocols from NewTom 3GTM (Quantitative Radiology s.r.l, Verona, Veneto, Italy) and i-CATTM (Imaging Sciences International, Hatfield, PA) units. Horizontal (A–B) and vertical (C–D) distances were assessed from axial tomograms and measured using a digital calliper that provided the gold standard for actual values. Results There were differences when considering acquisition protocols to each CBCT unit. Concerning all analysed protocols from i-CATTM and Newtom 3GTM, both A–B and C–D distances presented underestimated values. Measurements of the axial images obtained from NewTom 3GTM (6 inch 0.16 mm and 9 inch 0.25 mm) were similar to the ones obtained from i-CATTM (13 cm 20 s 0.3 mm, 13 cm 20 s 0.4 mm and 13 cm 40 s 0.25 mm). Conclusion The use of different protocols from CBCT machines influences linear measurements assessed from axial images. Linear distances were underestimated in both equipments. Our findings suggest that the best protocol for the i-CATTM is 13 cm 20 s 0.3 mm and for the NewTom 3GTM, the use of 6 inch or 9 inch is recommended. PMID:21831977

  15. Biomechanical Role of Bone Anisotropy Estimated on Clinical CT Scans by Image Registration.

    Science.gov (United States)

    Taghizadeh, Elham; Reyes, Mauricio; Zysset, Philippe; Latypova, Adeliya; Terrier, Alexandre; Büchler, Philippe

    2016-08-01

    Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

  16. Volume-of-change cone-beam CT for image-guided surgery

    Science.gov (United States)

    Lee, Junghoon; Webster Stayman, J.; Otake, Yoshito; Schafer, Sebastian; Zbijewski, Wojciech; Khanna, A. Jay; Prince, Jerry L.; Siewerdsen, Jeffrey H.

    2012-08-01

    C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D-2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRRs) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector. The VOCs were reconstructed from a varying number of images (10-66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15-20 images were used, allowing dose reduction by the factor of 10-20.

  17. Robust linear registration of CT images using random regression forests

    Science.gov (United States)

    Konukoglu, Ender; Criminisi, Antonio; Pathak, Sayan; Robertson, Duncan; White, Steve; Haynor, David; Siddiqui, Khan

    2011-03-01

    Global linear registration is a necessary first step for many different tasks in medical image analysis. Comparing longitudinal studies1, cross-modality fusion2, and many other applications depend heavily on the success of the automatic registration. The robustness and efficiency of this step is crucial as it affects all subsequent operations. Most common techniques cast the linear registration problem as the minimization of a global energy function based on the image intensities. Although these algorithms have proved useful, their robustness in fully automated scenarios is still an open question. In fact, the optimization step often gets caught in local minima yielding unsatisfactory results. Recent algorithms constrain the space of registration parameters by exploiting implicit or explicit organ segmentations, thus increasing robustness4,5. In this work we propose a novel robust algorithm for automatic global linear image registration. Our method uses random regression forests to estimate posterior probability distributions for the locations of anatomical structures - represented as axis aligned bounding boxes6. These posterior distributions are later integrated in a global linear registration algorithm. The biggest advantage of our algorithm is that it does not require pre-defined segmentations or regions. Yet it yields robust registration results. We compare the robustness of our algorithm with that of the state of the art Elastix toolbox7. Validation is performed via 1464 pair-wise registrations in a database of very diverse 3D CT images. We show that our method decreases the "failure" rate of the global linear registration from 12.5% (Elastix) to only 1.9%.

  18. Blockwise conjugate gradient methods for image reconstruction in volumetric CT.

    Science.gov (United States)

    Qiu, W; Titley-Peloquin, D; Soleimani, M

    2012-11-01

    Cone beam computed tomography (CBCT) enables volumetric image reconstruction from 2D projection data and plays an important role in image guided radiation therapy (IGRT). Filtered back projection is still the most frequently used algorithm in applications. The algorithm discretizes the scanning process (forward projection) into a system of linear equations, which must then be solved to recover images from measured projection data. The conjugate gradients (CG) algorithm and its variants can be used to solve (possibly regularized) linear systems of equations Ax=b and linear least squares problems minx∥b-Ax∥2, especially when the matrix A is very large and sparse. Their applications can be found in a general CT context, but in tomography problems (e.g. CBCT reconstruction) they have not widely been used. Hence, CBCT reconstruction using the CG-type algorithm LSQR was implemented and studied in this paper. In CBCT reconstruction, the main computational challenge is that the matrix A usually is very large, and storing it in full requires an amount of memory well beyond the reach of commodity computers. Because of these memory capacity constraints, only a small fraction of the weighting matrix A is typically used, leading to a poor reconstruction. In this paper, to overcome this difficulty, the matrix A is partitioned and stored blockwise, and blockwise matrix-vector multiplications are implemented within LSQR. This implementation allows us to use the full weighting matrix A for CBCT reconstruction without further enhancing computer standards. Tikhonov regularization can also be implemented in this fashion, and can produce significant improvement in the reconstructed images.

  19. Improving Low-dose Cardiac CT Images based on 3D Sparse Representation

    Science.gov (United States)

    Shi, Luyao; Hu, Yining; Chen, Yang; Yin, Xindao; Shu, Huazhong; Luo, Limin; Coatrieux, Jean-Louis

    2016-03-01

    Cardiac computed tomography (CCT) is a reliable and accurate tool for diagnosis of coronary artery diseases and is also frequently used in surgery guidance. Low-dose scans should be considered in order to alleviate the harm to patients caused by X-ray radiation. However, low dose CT (LDCT) images tend to be degraded by quantum noise and streak artifacts. In order to improve the cardiac LDCT image quality, a 3D sparse representation-based processing (3D SR) is proposed by exploiting the sparsity and regularity of 3D anatomical features in CCT. The proposed method was evaluated by a clinical study of 14 patients. The performance of the proposed method was compared to the 2D spares representation-based processing (2D SR) and the state-of-the-art noise reduction algorithm BM4D. The visual assessment, quantitative assessment and qualitative assessment results show that the proposed approach can lead to effective noise/artifact suppression and detail preservation. Compared to the other two tested methods, 3D SR method can obtain results with image quality most close to the reference standard dose CT (SDCT) images.

  20. Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Mieville, Frederic A.; Bochud, Francois O.; Verdun, Francis R. [Lausanne University Hospital, Institute of Radiation Physics, Lausanne (Switzerland); Berteloot, Laureline; Brunelle, Francis [Necker Children' s Hospital of Paris and University of Paris Descartes, Department of Pediatric Radiology, Paris (France); Grandjean, Albane; Ayestaran, Paul [General Electric Medical Systems Europe, Paris (France); Gudinchet, Francois; Schmidt, Sabine [Lausanne University Hospital, Department of Radiology, Lausanne (Switzerland)

    2013-03-15

    The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO trademark is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. To evaluate the potential of VEO trademark on diagnostic image quality and dose reduction in pediatric chest CT examinations. Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDI{sub vol} 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection. (orig.)

  1. Material Science Image Analysis using Quant-CT in ImageJ

    Energy Technology Data Exchange (ETDEWEB)

    Ushizima, Daniela M.; Bianchi, Andrea G. C.; DeBianchi, Christina; Bethel, E. Wes

    2015-01-05

    We introduce a computational analysis workflow to access properties of solid ob