WorldWideScience

Sample records for ct head scans

  1. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  2. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  3. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  4. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  5. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  6. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  8. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2009-01-01

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  9. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E. [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia 5000 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Division of Medical Imaging, Women' s and Children' s Hospital, North Adelaide, South Australia 5006 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia)

    2009-09-15

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  10. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Liu, Q; Qiu, J; Zhuo, W [Institute of Radiation Medicine Fudan University, Shanghai (China); Majer, M; Knezevic, Z; Miljanic, S [Radiation Chemistry and Dosimetry Laboratory, Ruder Boskovic Institute, Zagreb (Croatia); Hrsak, H [Clinical Hospital Centre Zagreb, Zagreb (Croatia)

    2016-06-15

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  12. Analysis of lenses absorbed dose in head CT scan with the use of bismuth shielding

    Energy Technology Data Exchange (ETDEWEB)

    Santos, F.S.; Santana, P.C., E-mail: fernanda.stephaniebh@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil); Mourão, A.P. [Centro de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. However, CT scan usually requires a higher radiation exposure than a conventional radiography examination. Head CT scans are used for diagnosis of traumatic head injuries, infections and other diseases with instability. Based on this information, it was studied the dose variation deposited in the lenses and in nearby organs, such as: pharynx, hypophysis and salivary gland with and without the use of bismuth shield. In this study a head CT scan was performed on anthropomorphic male phantom using a GE scanner. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. The results show that the lenses had a reduction of 26% of the dose with the use of the bismuth shield. (author)

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  14. Knowledge Representation Of CT Scans Of The Head

    Science.gov (United States)

    Ackerman, Laurens V.; Burke, M. W.; Rada, Roy

    1984-06-01

    We have been investigating diagnostic knowledge models which assist in the automatic classification of medical images by combining information extracted from each image with knowledge specific to that class of images. In a more general sense we are trying to integrate verbal and pictorial descriptions of disease via representations of knowledge, study automatic hypothesis generation as related to clinical medicine, evolve new mathematical image measures while integrating them into the total diagnostic process, and investigate ways to augment the knowledge of the physician. Specifically, we have constructed an artificial intelligence knowledge model using the technique of a production system blending pictorial and verbal knowledge about the respective CT scan and patient history. It is an attempt to tie together different sources of knowledge representation, picture feature extraction and hypothesis generation. Our knowledge reasoning and representation system (KRRS) works with data at the conscious reasoning level of the practicing physician while at the visual perceptional level we are building another production system, the picture parameter extractor (PPE). This paper describes KRRS and its relationship to PPE.

  15. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  16. Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind

    International Nuclear Information System (INIS)

    Michel, Morgane; Jacob, Sophie; Roger, Gilles; Pelosse, Béatrice; Laurier, Dominique; Le Pointe, Hubert Ducou; Bernier, Marie-Odile

    2012-01-01

    Objectives: The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Methods: Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Results: Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7 mSv and 168 mGy, respectively. Conclusion: A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients’ families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT.

  17. Dose profile study in head CT scans using a male anthropomorphic phantom

    International Nuclear Information System (INIS)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P.

    2017-01-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  18. Dose profile study in head CT scans using a male anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P., E-mail: amlgphys@gmail.com, E-mail: pridili@gmail.com, E-mail: apratabhz@gmail.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  19. Indications for direct multidirectional or multiplanar electronic reconstructions in CT-scanning of the head

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Veiga-Pires, J.A.; Gooskens, R.; Troost, J.

    1982-01-01

    The authors set out to indicate the optimal applications at minimum radiation penalty of both direct multidirectional and multiplanar electronic reconstruction modes in CT-scanning of the head by means of two illustrative case reports of midline congenital tumours. (orig.)

  20. The profile of CT scan findings in acute head trauma in Orotta ...

    African Journals Online (AJOL)

    The use of investigation modalities are influenced by socioeconomic and cost effectiveness of the tests. Objective and methods: The purpose of the present five months observational study was to describe the profile of cranial computed tomography (CT) scan findings of 110 cases of acute head trauma in Orotta Hospital.

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  2. A case of linear nevus sebaceous syndrome showing abnormalities by head CT scan

    International Nuclear Information System (INIS)

    Matsuda, Yoshio; Kuraya, Kazue; Sumiyoshi, Minoru; Seki, Shuichiro; Murakami, Naoki

    1982-01-01

    A female baby weighing 2,702 g, who was delivered spontaneously after 37 weeks of gestation, showed linear nevus sebaceous syndrome with abnormalities on EEG and head CT scan. Immediately after birth, the baby showed abnormalities of the skin in the left half of the body, especially from the head to the face. At the same time, EEG showed a low voltage on the affected side, and head CT scan showed expansion of the lateral ventricle. Funduscopic findings showed retinochoroidal toxoplasmosis-like degeneration. This disease has been rarely reported. An early diagnosis is seemed to be important since the skin lesion per se was premalignant, and generalized abnormalities including those of the central nervous system occurred concurrently. (Chiba, N.)

  3. Radiation dose reduction at a price: the effectiveness of a thyroid shield during head CT scanning

    International Nuclear Information System (INIS)

    Fu Qiang; Lu Tao; Zhang Ling

    2008-01-01

    Objective: To assess radiation dose to the thyroid in patients undergoing head CT scanning and to evaluate dose reduction to the thyroid by load shielding. Methods: A post-morterm was scanned by different model and study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. (a)No thyroid shields and (b) thyroid shield. One thermoluminescent dosimeters (TLDs)were placed over the thyroid gland center, A thyroid lead shield (Pb eq 0.5mm)was placed around the neck of post-morterm. Scan parameter, CTDIw and DLP were recorded. Results: (a) 0.207mSv; (b) 0.085mSv. A mean effective radiation dose reduction of 58% was seen in the shielded versus the unshielded. Conclusion: Thyroid exposure to scattered radiation from head CT scanning only once is associated with a low but not negligible risk of cancer, but accumulatived doses to the thyroid are serious, highlighting the need for increased awareness of patient radiation protection. Thyroid lead shielding yields significant radiation protection, which should be used routinely during head CT scan. (authors)

  4. Four cases with localized brain-stem lesion on CT scan following closed head injury

    International Nuclear Information System (INIS)

    Saeki, Naokatsu; Odaki, Masaru; Oka, Nobuo; Takase, Manabu; Ono, Junichi.

    1981-01-01

    Cases of primary brain-stem injury following closed head injury, verified by a CT scan, have been increasingly reported. However, most of them have other intracranial lesions in addition to the brain stem, resulting in a poor outcome. The CT scan of 200 cases with severe head injury-Araki's classification of types 3 and 4 - were analysed. Four cases out of them had localized brain-stem lesion without any other significant intracranial injury on a CT scan at the acute stage and had a better outcome than had previously been reported. In this analysis, these 4 cases were studied, and the CT findings, prognosis, and pathogenesis of the localized brain-stem injury were discussed. Follow-up CT of three cases, and taken one month or more later, showed diffuse cortical atrophy. This may indicate the presence of diffuse cerebral injury which could not be seen on CT scans at the acute stage. This atrophic change may also be related with the mechanism of posttraumatic conscious impairment and posttraumatic neurological deficits, such as mental symptoms and impairment of the higher cortical function. Shearing injury is a probable pathogenesis for this diffuse cortical injury. On the other hand, one case did not have any cortical atrophy on a follow-up CT scan. Therefore, this is a case with a localized primary brain-stem injury. Coup injury against the brain stem by a tentorial margin in a case with a small tentorial opening is a possible mechanism producing the localized brain-stem injury. (J.P.N.)

  5. On the uncertainties in effective dose estimates of adult CT head scans

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan against the risk of radiation-induced cancer. The question arises: What is the uncertainty in these effective dose estimates? This study calculates the uncertainty of effective dose estimates produced by three computer programs (CT-EXPO, CTDosimetry, and ImpactDose) and one method that makes use of dose-length product (DLP) values. Uncertainties were calculated in accordance with an internationally recognized uncertainty analysis guide. For each of the four methods, the smallest and largest overall uncertainties (stated at the 95% confidence interval) were: 20%-31% (CT-EXPO), 15%-28% (CTDosimetry), 20%-36% (ImpactDose), and 22%-32% (DLP), respectively. The overall uncertainties for each method vary due to differences in the uncertainties of factors used in each method. The smallest uncertainties apply when the CT dose index for the scanner has been measured using a calibrated pencil ionization chamber

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  9. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  10. Study of CT head scans using different voltages: image quality evaluation

    International Nuclear Information System (INIS)

    Pacheco de Freitas C, I.; Prata M, A.; Alonso, T. C.; Santana, P.

    2016-10-01

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  11. Does head CT scan pathology predict outcome after mild traumatic brain injury?

    Science.gov (United States)

    Lannsjö, M; Backheden, M; Johansson, U; Af Geijerstam, J L; Borg, J

    2013-01-01

    More evidence is needed to forward our understanding of the key determinants of poor outcome after mild traumatic brain injury (MTBI). A large, prospective, national cohort of patients was studied to analyse the effect of head CT scan pathology on the outcome. One-thousand two-hundred and sixty-two patients with MTBI (Glasgow Coma Scale score 15) at 39 emergency departments completed a study protocol including acute head CT scan examination and follow-up by the Rivermead Post Concussion Symptoms Questionnaire and the Glasgow Outcome Scale Extended (GOSE) at 3 months after MTBI. Binary logistic regression was used for the assessment of prediction ability. In 751 men (60%) and 511 women (40%), with a mean age of 30 years (median 21, range 6-94), we observed relevant or suspect relevant pathologic findings on acute CT scan in 52 patients (4%). Patients aged below 30 years reported better outcome both with respect to symptoms and GOSE as compared to patients in older age groups. Men reported better outcome than women as regards symptoms (OR 0.64, CI 0.49-0.85 for ≥3 symptoms) and global function (OR 0.60, CI 0.39-0.92 for GOSE 1-6). Pathology on acute CT scan examination had no effect on self-reported symptoms or global function at 3 months after MTBI. Female gender and older age predicted a less favourable outcome. The findings support the view that other factors than brain injury deserve attention to minimize long-term complaints after MTBI. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  12. Dose assessment of head CT examination by volume scanning with 320-area-detector

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Kobayashi, Masanao

    2009-01-01

    CT with the 320-area-detector (320-ADCT), first presented in 2007, still requires further basic studies, particularly in the field of dose assessment, as the CT has been widely spread in clinic due to its many advantages compared with the usual spiral CT. In this paper, the assessment in the title was thereby done in human phantom and a patient with suspicious acute cerebral infarction under different scanning modes (non-spiral, spiral and volume) for their comparison. Machines for 320-ADCT, and non-spiral and spiral CT were Toshiba Aquilion ONE, and Aquilion 64-MD, respectively. Scanning of the phantom and patient was individually conducted under similar conditions of tube voltage/ current, rotation time and length with the same field of view with defined nominal slice thicknesses. Alderson human body phantom in which 240 thermoluminescent dosimeters were indwelled, was used; doses were read by the thermoluminescence dosimeter (TLD) reader model 3000 (Kyokko Co.) after scanning; and effective doses were calculated with reference to ICRP publ. 102/103 equations for patient's head to be 4.2 (64-MDCT) and 6.6 (320-ADCT) mSv, which were respectively 6.4 and 5.4 mSv when estimated using the conversion coefficient and DLP (dose length product) in the texts. It was suggested that the exposure dose at the volume scanning by 320-ADCT can be reduced in the routine examination, and in the exact diagnosis, possibly increases. These doses can be reduced further by optimization of scanning conditions by additional basic investigations. (K.T.)

  13. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  14. Detection of treatment setup errors between two CT scans for patients with head and neck cancer

    International Nuclear Information System (INIS)

    Ezzell, Leah C.; Hansen, Eric K.; Quivey, Jeanne M.; Xia Ping

    2007-01-01

    Accuracy of treatment setup for head and neck patients undergoing intensity-modulated radiation therapy is of paramount importance. The conventional method using orthogonal portal images can only detect translational setup errors while the most frequent setup errors for head and neck patients could be rotational errors. With the rapid development of image-guided radiotherapy, three-dimensional images are readily acquired and can be used to detect both translational and rotational setup errors. The purpose of this study is to determine the significance of rotational variations between two planning CT scans acquired for each of eight head and neck patients, who experienced substantial weight loss or tumor shrinkage. To this end, using a rigid body assumption, we developed an in-house computer program that utilizes matrix transformations to align point bony landmarks with an incremental best-fit routine. The program returns the quantified translational and rotational shifts needed to align the scans of each patient. The program was tested using a phantom for a set of known translational and rotational shifts. For comparison, a commercial treatment planning system was used to register the two CT scans and estimate the translational errors for these patients. For the eight patients, we found that the average magnitudes and standard deviations of the rotational shifts about the transverse, anterior-posterior, and longitudinal axes were 1.7±2.3 deg., 0.8±0.7 deg., and 1.8±1.1 deg., respectively. The average magnitudes and standard deviations of the translational shifts were 2.5±2.6 mm, 2.9±2.8 mm, 2.7±1.7 mm while the differences detected between our program and the CT-CT fusion method were 1.8±1.3 mm, 3.3±5.4 mm, and 3.0±3.4 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. A trend of larger rotational errors resulting in larger translational differences between the two methods was observed. In conclusion, conventional

  15. Prediction value of the Canadian CT head rule and the New Orleans criteria for positive head CT scan and acute neurosurgical procedures in minor head trauma: a multicenter external validation study.

    Science.gov (United States)

    Bouida, Wahid; Marghli, Soudani; Souissi, Sami; Ksibi, Hichem; Methammem, Mehdi; Haguiga, Habib; Khedher, Sonia; Boubaker, Hamdi; Beltaief, Kaouthar; Grissa, Mohamed Habib; Trimech, Mohamed Naceur; Kerkeni, Wiem; Chebili, Nawfel; Halila, Imen; Rejeb, Imen; Boukef, Riadh; Rekik, Noureddine; Bouhaja, Bechir; Letaief, Mondher; Nouira, Semir

    2013-05-01

    The New Orleans Criteria and the Canadian CT Head Rule have been developed to decrease the number of normal computed tomography (CT) results in mild head injury. We compare the performance of both decision rules for identifying patients with intracranial traumatic lesions and those who require an urgent neurosurgical intervention after mild head injury. This was an observational cohort study performed between 2008 and 2011 on patients with mild head injury who were aged 10 years or older. We collected prospectively clinical head CT scan findings and outcome. Primary outcome was need for neurosurgical intervention, defined as either death or craniotomy, or the need of intubation within 15 days of the traumatic event. Secondary outcome was the presence of traumatic lesions on head CT scan. New Orleans Criteria and Canadian CT Head Rule decision rules were compared by using sensitivity specifications and positive and negative predictive value. We enrolled 1,582 patients. Neurosurgical intervention was performed in 34 patients (2.1%) and positive CT findings were demonstrated in 218 patients (13.8%). Sensitivity and specificity for need for neurosurgical intervention were 100% (95% confidence interval [CI] 90% to 100%) and 60% (95% CI 44% to 76%) for the Canadian CT Head Rule and 82% (95% CI 69% to 95%) and 26% (95% CI 24% to 28%) for the New Orleans Criteria. Negative predictive values for the above-mentioned clinical decision rules were 100% and 99% and positive values were 5% and 2%, respectively, for the Canadian CT Head Rule and New Orleans Criteria. Sensitivity and specificity for clinical significant head CT findings were 95% (95% CI 92% to 98%) and 65% (95% CI 62% to 68%) for the Canadian CT Head Rule and 86% (95% CI 81% to 91%) and 28% (95% CI 26% to 30%) for the New Orleans Criteria. A similar trend of results was found in the subgroup of patients with a Glasgow Coma Scale score of 15. For patients with mild head injury, the Canadian CT Head Rule had higher

  16. Open source deformable image registration system for treatment planning and recurrence CT scans. Validation in the head and neck region

    International Nuclear Information System (INIS)

    Zukauskaite, Ruta; Brink, Carsten; Hansen, Christian Roenn; Bertelsen, Anders; Johansen, Joergen; Eriksen, Jesper Grau; Grau, Cai

    2016-01-01

    Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p < 0.001) and tissue rigidity (r = 0.54, p < 0.001). DIR using elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images. (orig.) [de

  17. Open source deformable image registration system for treatment planning and recurrence CT scans : Validation in the head and neck region.

    Science.gov (United States)

    Zukauskaite, Ruta; Brink, Carsten; Hansen, Christian Rønn; Bertelsen, Anders; Johansen, Jørgen; Grau, Cai; Eriksen, Jesper Grau

    2016-08-01

    Clinical application of deformable registration (DIR) of medical images remains limited due to sparse validation of DIR methods in specific situations, e. g. in case of cancer recurrences. In this study the accuracy of DIR for registration of planning CT (pCT) and recurrence CT (rCT) images of head and neck squamous cell carcinoma (HNSCC) patients was evaluated. Twenty patients treated with definitive IMRT for HNSCC in 2010-2012 were included. For each patient, a pCT and an rCT scan were used. Median interval between the scans was 8.5 months. One observer manually contoured eight anatomical regions-of-interest (ROI) twice on pCT and once on rCT. pCT and rCT images were deformably registered using the open source software elastix. Mean surface distance (MSD) and Dice similarity coefficient (DSC) between contours were used for validation of DIR. A measure for delineation uncertainty was estimated by assessing MSD from the re-delineations of the same ROI on pCT. DIR and manual contouring uncertainties were correlated with tissue volume and rigidity. MSD varied 1-3 mm for different ROIs for DIR and 1-1.5 mm for re-delineated ROIs performed on pCT. DSC for DIR varied between 0.58 and 0.79 for soft tissues and was 0.79 or higher for bony structures, and correlated with the volumes of ROIs (r = 0.5, p elastix in HNSCC on planning and recurrence CT scans is feasible; an uncertainty of the method is close to the voxel size length of the planning CT images.

  18. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Klasic, B. [Hospital for pulmonary diseases, Zagreb (Croatia); Knezevic, Z.; Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Brnic, Z.; Novacic, K. [Merkur Univ. Hospital, Zagreb (Croatia)

    2006-07-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  19. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    International Nuclear Information System (INIS)

    Klasic, B.; Knezevic, Z.; Vekic, B.; Brnic, Z.; Novacic, K.

    2006-01-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  20. Indications of CT scan after minor head trauma in children. Can age younger than 2 years be a risk factor?

    International Nuclear Information System (INIS)

    Ozaki, Mitsunori; Seo, Yoshinobu; Nakamura, Hirohiko

    2010-01-01

    The indications of CT scan after minor head trauma in children are often discussed, including risks of radiation-induced malignancy. Our aim is to identify whether children younger than 2 years have greater risk of traumatic brain injury compared to older children. We enrolled and analysed 1,830 patients younger than 7 years who underwent CT scans after head trauma in our institute. Patients without any symptoms (n=916) were defined as Group A (age<2: n=391, age 2-6: n=525). Patients with extracranial traumatic findings such as scalp hematoma or laceration, and without any neurological symptoms (n=600) were defined as Group B (age<2: n=163, age 2-6: n=437). In order to analyze whether children younger than 2 years have risks of abnormal CT findings due to head trauma, we used the chi-square test in both Group A and Group B. A P-value of less than 0.05 was considered statistically significant. In Group A, there was no significant difference in the frequency of abnormal CT findings between the younger and older groups (p=0.526). In Group B, however, there was a significant difference between those groups (p=0.0186). We suggest that, based on our findings, children younger than 2 years without any symptoms don't have a greater risk of brain injury compared to older children after minor head trauma. This study might contribute to save those children from receiving unnecessary radiation. (author)

  1. Revascularization of femoral head ischemic necrosis with vascularized bone graft: A CT scan experimental study

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Knapp, K.; Gomez Castresana, F.; Benito, M.

    1990-01-01

    An ischemic necrosis of the femoral head was induced in 15 mongrel adult dogs using the technique described by Gartsman et al. Five weeks later, a free vascularized rib graft was transferred into the previously induced ischemic femoral head. High resolution computed tomographic scanning was used to evaluate revascularization 4, 8 and 12 weeks after grafting. The femoral head exhibited new vessel formation throughout the study. Arterial terminal branches arising from the rib graft medullary and periosteal circulations extended beyond the rib graft, entered the head, and reached the subchondral plate. Even where the rib graft did not replenish the central core of the head, there was vascular supply from the grafted bone's vascular tree. These results suggest that a free vascularized bone graft is able to revascularize an experimentally induced ischemic femoral head necrosis. (orig.)

  2. The application of dose-reduction simulation in neonatal head CT scan

    International Nuclear Information System (INIS)

    Liu Yue; Peng Yun; Zeng Jinjin; Zhang Qifeng; Li Jianying

    2009-01-01

    Objective: To determine the effects of dose reduction on multi-slice spiral CT (MSCT) of neonatal head and assess the lowest possible radiation for acceptable clinical images. Methods: Fifty-seven newborns suspected intracranial hemorrhage were entered into the study and underwent MSCT scans. Original images at three anatomic levels (posterior fossa, basal ganglia, centrum semiovale) were collected and synthetic noise was added so as to simulate dose reductions of 25%, 40%, 50% and 70%, respectively by using the noise addition tool. A total of 855 image data sets were obtained for the 57 patients. Original and simulated dose-reduction scan images were analyzed. Image noise and image quality were assessed by two independent experienced pediatric radiologists using diagnostic acceptability score, subjective image noise score on a 5-point scale and objective noise index. Image noise was measured by respectively placing region of interest (ROI) at cerebellum, thalamus and corona radiata of 3 different slices. And the noise index and mean value was calculated. The degree of inter-observer concordance was determined by Kappa statistical analysis. The Spearman statistical correlations between the noise index and diagnostic acceptability score were performed. Results: On the images of original dose and simulated dose reductions of 25%, 40%, 50% and 70%, the diagnostic acceptability was 4.47±0.51, 3.96±0.33, 3.21±0.45, 2.92±0.32, and 1.85±0.57, respectively, the subjective image scores were 1.62±0.48, 1.99±0.48, 2.76±0.81, 3.19±0.67, and 4.27±0.54, respectively, the noise index were 1.90±0.19, 2.17±0.20. 2.44± 0.25, 2.68±0.28, and 3.37±0.39, respectively. The two radiologists had good interobserver agreement for diagnostic acceptability (K=0.860, P=0.017) and for image noise scoring(K=0.630, P=0.022). There was significant statistical correlation between image noise index and diagnostic acceptability (r= 0.826,P=0.001). At 40% dose reduction to the standard

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  4. Dosimetric study on head CT scans using adult and newborn phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva de O, G. A.; Prata M, A., E-mail: giovanni_paiva@hotmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography is the radiodiagnostic method that most contributes to the dose deposition in population. Therefore, the dose reductions used in these tests are very important, especially for pediatric patients who have a life expectancy greater than the rest of the population. This study purpose to compare the doses generated from newborns compared to adult patients in head computed tomography scans. Two head phantoms in a cylindrical shape made in PMMA were used, one to adult and another to newborn patient dimensions. The pediatric routine scan protocol from a radiological service was used for the computed tomography scans. They were performed in General Electric Computed Tomography scanner, Bright Speed model with 4 channels. The absorbed dose measurements were performed with a pencil chamber placed into both phantoms. The newborn head phantom was developed in order to compare the amount of absorbed dose by the phantoms when it is used the same acquisition protocol. The dose found for newborn phantom was 29.9% higher than the adult phantom. (Author)

  5. Dosimetric study on head CT scans using adult and newborn phantoms

    International Nuclear Information System (INIS)

    Paiva de O, G. A.; Prata M, A.

    2016-10-01

    Computed tomography is the radiodiagnostic method that most contributes to the dose deposition in population. Therefore, the dose reductions used in these tests are very important, especially for pediatric patients who have a life expectancy greater than the rest of the population. This study purpose to compare the doses generated from newborns compared to adult patients in head computed tomography scans. Two head phantoms in a cylindrical shape made in PMMA were used, one to adult and another to newborn patient dimensions. The pediatric routine scan protocol from a radiological service was used for the computed tomography scans. They were performed in General Electric Computed Tomography scanner, Bright Speed model with 4 channels. The absorbed dose measurements were performed with a pencil chamber placed into both phantoms. The newborn head phantom was developed in order to compare the amount of absorbed dose by the phantoms when it is used the same acquisition protocol. The dose found for newborn phantom was 29.9% higher than the adult phantom. (Author)

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  10. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Claudia C.; Stern, Stanley H.; Chakrabarti, Kish [U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993 (United States); Minniti, Ronaldo [National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899 (United States); Parry, Marie I. [Walter Reed National Military Medical Center, 8901 Rockville Pike, Bethesda, Maryland 20889 (United States); Skopec, Marlene [National Institutes of Health, 9000 Rockville Pike, Bethesda, Maryland 20892 (United States)

    2013-08-15

    Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 m

  11. Computerized tomography(CT) in patients with head injuries, assessment of outcome based upon initial clinical findings and initial CT scans

    International Nuclear Information System (INIS)

    Espersen, J.O.; Petersen, O.F.

    1982-01-01

    In this study, which comprises 144 consecutive head injuries, the initial clinical assessment and the findings of the initial CT scan are relatd to the outcome. The mortality is related to the patient's level of consiousness and pupillary light reflex on admission. The disability rate (= number of disabled/number of survivors) was independent of the level of consiousness but closely related to pupillary light reaction. Diminished and obliterated basal cisterns were bad prognostic signs, with a mortality rate of 66% in the latter group. Both disability and mortality increase with the number of different lesion types. (Author)

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  16. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  17. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    International Nuclear Information System (INIS)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-01-01

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  18. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  1. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  2. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  3. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  4. The profile of CT scan findings in acute head trauma in Orotta ...

    African Journals Online (AJOL)

    In developing countries accident rates in general and ... injury refers to any damage to the scalp, skull, or brain. There are two ... and disability in children and adults in their most productive ... and gender distribution, and CT findings related to.

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  7. Measurement of adult and paediatric patient doses during head CT scan

    International Nuclear Information System (INIS)

    Suliman, S. A.

    2011-03-01

    CT represents only 5% of all x-ray imaging and yet the radiation from CT examination is 40% to 67% of all medical radiation. The dose from single CT examinations can range from 1.0 mSv to 27.0 mSv. The radiation given by diagnostic CT is comparable to the low dose received by Japanese survivors of the atomic bombs. As per united nations scientific committee UNSCEAR 2000(2), CT contributes over 34% collective dose from diagnostic x-ray examinations in the world. This figure is much larger than this for developed countries, approaching as much as 50% to 70% even thought the frequency of CT examinations in these countries is of the order of 5 to 12%. It thus implies a small but statistically significant increased risk for developing cancer as a result of the radiation. The objective of the study were to investigate doses from CT examinations of adult and paediatric patients in brain CT examination and compare the doses with international standard as provided in DRLs. A total of 59 patients (paediatric and adults) were examined at the department of radiology, Al Ribat University Hospital-Khartoum. The mean age was 40.80 years for adults while the mean weight was 70.04 kg and the mean age for paediatric was 5.10 years while the mean weight was 20kg. DLP for adults were 1000.25 mGy.cm, 733.33 for paediatrics. The mean effective dose for adults patient was 0.48 mSv in rang (0.49-0.44)mSv, while for paediatric patients was 0.31 mSv in rang between (0.49-0.11) mSv. The DRL was 1120 mGy.cm, a value which is higher than the European Guidelines on quality criteria for computed tomography. The study has shown a great need for referring criteria, continuous training of staff in radiation dose optimization concepts. Further studies are required in order to establish a reference level in Sudan.(Author)

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  9. Automated volume analysis of head and neck lesions on CT scans using 3D level set segmentation

    International Nuclear Information System (INIS)

    Street, Ethan; Hadjiiski, Lubomir; Sahiner, Berkman; Gujar, Sachin; Ibrahim, Mohannad; Mukherji, Suresh K.; Chan, Heang-Ping

    2007-01-01

    The authors have developed a semiautomatic system for segmentation of a diverse set of lesions in head and neck CT scans. The system takes as input an approximate bounding box, and uses a multistage level set to perform the final segmentation. A data set consisting of 69 lesions marked on 33 scans from 23 patients was used to evaluate the performance of the system. The contours from automatic segmentation were compared to both 2D and 3D gold standard contours manually drawn by three experienced radiologists. Three performance metric measures were used for the comparison. In addition, a radiologist provided quality ratings on a 1 to 10 scale for all of the automatic segmentations. For this pilot study, the authors observed that the differences between the automatic and gold standard contours were larger than the interobserver differences. However, the system performed comparably to the radiologists, achieving an average area intersection ratio of 85.4% compared to an average of 91.2% between two radiologists. The average absolute area error was 21.1% compared to 10.8%, and the average 2D distance was 1.38 mm compared to 0.84 mm between the radiologists. In addition, the quality rating data showed that, despite the very lax assumptions made on the lesion characteristics in designing the system, the automatic contours approximated many of the lesions very well

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... is reduced. Though the scanning itself causes no pain, there may be some discomfort from having to ... time staying still, are claustrophobic or have chronic pain, you may find a CT exam to be ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... that lasts for at most a minute or two. You may experience a sensation like you have ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... its ability to image bone, soft tissue and blood vessels all at the same time. Unlike conventional x-rays, CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies. You ... a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tissue damage in patients with facial trauma, and planning surgical reconstruction. diagnose diseases of the temporal bone ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. No radiation remains in a ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... See the Safety page for more information about pregnancy and x-rays. top of page What does ... See the Safety page for more information about pregnancy and x-rays. CT scanning is, in general, ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... liver, shows up in shades of gray, and air appears black. With CT scanning, numerous x-ray ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... therapy for brain cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... up in shades of gray, and air appears black. With CT scanning, numerous x-ray beams and ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  3. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. A ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ... us improve RadiologyInfo.org by taking our brief survey: Survey Do you have a personal story about ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. A ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  8. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  10. CT of the neonatal head

    International Nuclear Information System (INIS)

    Mohan, S.; Rogan, E.A.; Batty, R.; Raghavan, A.; Whitby, E.H.; Hart, A.R.; Connolly, D.J.A.

    2013-01-01

    Computed tomography (CT) is used less often than other techniques on neonatal units. However, in the acute setting, CT can be invaluable in diagnosing or excluding potentially life-threatening conditions and guiding initial management in neonates. Common indications for scanning include trauma, suspected non-accidental injury, infection, or an acute hypoxic or metabolic event. The aim of this review is to provide an overview of the normal neonatal head at CT and compare this to the common pathological abnormalities. Several key features of each condition will be highlighted. It is important to note that some pathological conditions can have overlapping features at CT and, therefore, the clinical history and additional investigations are also of key importance in determining the diagnosis

  11. Does trauma team activation associate with the time to CT scan for those suspected of serious head injuries?

    Science.gov (United States)

    Rados, Alma; Tiruta, Corina; Xiao, Zhengwen; Kortbeek, John B; Tourigny, Paul; Ball, Chad G; Kirkpatrick, Andrew W

    2013-11-18

    Traumatic brain injury (TBI) constitutes the leading cause of posttraumatic mortality. Practically, the major interventions required to treat TBI predicate expedited transfer to CT after excluding other immediately life-threatening conditions. At our center, trauma responses variably consist of either full trauma activation (FTA) including an attending trauma surgeon or a non-trauma team response (NTTR). We sought to explore whether FTAs expedited the time to CT head (TTCTH). Retrospective review of augmented demographics of 88 serious head injuries identified from a Regional Trauma Registry within one year at a level I trauma center. The inclusion criteria consisted of a diagnosis of head injury recorded as intubated or GCS FTA (median 50 vs. 26 minutes, p FTA). Without FTA, most delays (69%) were for emergency intubation. TTCTH after securing the airway was longer for NTTR group (median 38 vs. 26 minutes, p =0.0013). Even with no requirements for ED interventions, TTCTH for FTA was less than half versus NTTR (25 vs. 61 minutes, p =0.0013). Multivariate regression analysis indicated age and FTA with an attending surgeon as significant predictors of TTCTH, although the majority of variability in TTCTH was not explained by these two variables (R² = 0.33). Full trauma activations involving attending trauma surgeons were quicker at transferring serious head injury patients to CT. Patients with FTA were younger and more seriously injured. Discerning the reasons for delays to CT should be used to refine protocols aimed at minimizing unnecessary delays and enhancing workforce efficiency and clinical outcome.

  12. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

    International Nuclear Information System (INIS)

    Aw-Zoretic, J.; Seth, D.; Katzman, G.; Sammet, S.

    2014-01-01

    Purpose: The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). Method and materials: A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Results: Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10–18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Conclusion: Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... conditions may increase the risk of an unusual adverse effect. The radiologist also should know if you have ... CT scanning may eliminate the need for exploratory surgery and surgical ... immediate side effects. Risks There is always a slight chance of ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... for children who cannot hold still. Motion will cause blurring of the images and degrade the quality ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different body parts absorb the x-rays in varying ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... shield may stay in the room with their child. However, the technologist will always be able to ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... operates the scanner and monitors your examination in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much ...

  1. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  2. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  3. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  4. Estimation of skin, organ and effective doses of patients who undertake head CT scan in 4 medical radiography

    International Nuclear Information System (INIS)

    Bahreyni Toosi, M.T.; Khalilpour, M.

    2007-01-01

    Complete test of publication follows. CT was first introduced into clinical practice in 1972, and has since grown into one of the predominant diagnostic procedures. In this work we have estimated patient dose arising from CT examination of brain in four hospitals in Mashhad. Organ and effective doses were estimated for 123 patients who underwent CT examination of brain. 'ImPACT' version 0.99w was used to estimate organ and effective dose. ESD of same patients were measured by TLD-100. Brain examinations were performed with fixed kV, mA and T (slice thickness) for each scanner. The CT Scanners investigated in this study were GE HiLight, Siemens Somatom AR-T, Somatom Balance and Shimadzu SCT. Summary of our findings are as follows: Application of 'ImPACT' software enabled us to compute Bone marrow (red), Brain, Thyroid and effective doses of all patients. Table 1 shows the average organ dose (Brain, Bone marrow (red), Thyroid), mean effective dose and mean ESD were measured by TLD for each patients. Patients, who were scanned by Siemens Somatom AR-T, received maximum organ dose (brain) equal to 25.64 mGy and minimum organ dose equal to 0.21 mGy was delivered to thyroid of patients who were scanned by GE HiLight Scanner. Our average effective dose (0.54 ± 0.02 mSv) is smaller than the corresponding value (0.75 ± 0.03 mSv) obtained by Peter F. Caracappa (M.Sc dissertation submitted to the Faculty of Rensselaer Polytechnic Institute, Troy, New York April 2004). Scanning by Siemens Somatom AR-T, gave rise to maximum ESD (equal to 16.22 mGy). On the other hand minimum ESD (5.51 mGy) was achieved when patients were scanned by GE HiLight machine. ESD values and organ doses acquired in this work by two different methods, TLD measurement and computing by 'ImPACT' software; are in good agreement and this is an indication of the accuracy and validity of both sets of results.

  5. Gyral high density on CT scan after head injury; [sup 123]I-IMP SPECT and MRI findings in three children

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Takumi; Matsumoto, Kiyoshi (Showa Univ., Tokyo (Japan). School of Medicine); Sakamoto, Tetsuya; Aruga, Tohru

    1994-02-01

    The authors treated three children who had 'gyral high density' on plain CT scans after head injury with acute subdural hematoma. [sup 123]I-IMP SPECT (IMP) and MRI in the chronic stage were performed. All were males, about one year of age, with acute subdural hematoma. CT scan 48 hours after injury showed diffuse low density in the ipsilateral parenchyma with minimum midline shift, and IMP showed decreased activity in the same area. Plain CT scan 1 to 3 weeks after injury showed remarkably high density along the gyri in part of the same area. This area was markedly enhanced on CT with contrast medium and showed decreased blood flow on IMP. This high density area disappeared within 2 months after injury and the area concerned showed brain atrophy. In the chronic stage (after 6 months), only the high density area along the gyri seen in the CT scan showed MRI evidence of ishemia, but there was no definite evidence of hemorrhage. All three children had hemiplegia at the time of discharge. The gyral high density suggests ischemic brain, but the pathophysiological process might be different from that of so-called hemorrhagic infarction. Presumably, it is due to incomplete autoregulation, the incomplete blood-brain barrier and the sensitivity to stimulation of cerebral blood vessels in the brains of infants. The intensity and range of the gyral high density are considered to be important in estimating the future amount of atrophic change in the insulted brain and the resulting sequelae. (author).

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  7. Is contrast-enhanced CT indicated in acute head injury

    International Nuclear Information System (INIS)

    Mauser, H.W.; Nieuwenhuizen, O. van; Veiga-Pires, J.A.

    1984-01-01

    The authors discuss the value of intravenous contrast enhancement in CT scanning in acute head injury. In a series of seventy consecutive patients they conclude that no incremental information was obtained by performing contrast-enhanced CT scans in the acute phase of the head injury. (orig.)

  8. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other ... aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  17. CT angiography - head and neck

    Science.gov (United States)

    ... your provider if you take the diabetes medicine metformin (Glucophage). You may need to take extra precautions. ... to the kidneys from the dye CT scans use more radiation than regular x-rays. Having many ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... wear during the procedure. Metal objects, including jewelry, eyeglasses, dentures and hairpins, may affect the CT images ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may ... hard time staying still, are claustrophobic or have chronic pain, you may find a CT exam to ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... detailed images of many types of tissue as well as the lungs, bones, and blood vessels. CT ... iodine is extremely rare, and radiology departments are well-equipped to deal with them. Because children are ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ... have diabetes —particularly if you are taking Glucophage . Women should always inform their physician and the CT ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner or may be over the weight limit—usually 450 pounds—for the moving table. Compared ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... brain cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to help save ... to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... to you, revolve around you during the imaging process. You will be alone in the exam room ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ... is also performed to: evaluate the extent of bone and soft tissue damage in patients with facial ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... a few seconds, and even faster in small children. Such speed is beneficial for all patients but ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images can be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... are claustrophobic or have chronic pain, you may find a CT exam to be stressful. The technologist ... 08, 2016 Send us your feedback Did you find the information you were looking for? Yes No ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... very much like other x-ray examinations. Different body parts absorb the x-rays in varying degrees. ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... quickly. When you enter the CT scanner, special light lines may be seen projected onto your body, ... its ability to image bone, soft tissue and blood vessels all at the same time. Unlike conventional ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the CT images and should be left at home or removed prior to your exam. You may also be asked to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... may increase the risk of an unusual adverse effect. The radiologist also should know if you have ... to urinate; however, this is actually a contrast effect and subsides quickly. When you enter the CT ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a very detailed multidimensional view of the body's interior. Refinements in detector technology allow nearly all CT ... a few seconds, and even faster in small children. Such speed is beneficial for all patients but ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. A diagnosis ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... have a known allergy to contrast material, or "dye," your doctor may prescribe medications (usually a steroid) ... like? The CT scanner is typically a large, box-like machine with a hole, or short tunnel, ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the CT images and should be left at home or removed prior to your exam. You may also be asked to remove hearing aids and removable dental work. Women will be asked to remove bras containing ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... hours prior to your exam. Leave jewelry at home and wear loose, comfortable clothing. You may be ... the CT images and should be left at home or removed prior to your exam. You may ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... your doctor to evaluate your face, sinuses, and skull or to plan radiation therapy for brain cancer. ... typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... works very much like other x-ray examinations. Different body parts absorb the x-rays in varying degrees. ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... area of the body being studied. top of page How is the ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  12. CT scan of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, T; Noguchi, S; Nishitani, H [National Sanatorium of Utano, Kyoto (Japan); Kitano, H; Ikegami, Y

    1981-04-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs.

  13. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    Konishi, Tetsuro; Noguchi, Sadako; Nishitani, Hiroshi; Kitano, Haruo; Ikegami, Yoshinori.

    1981-01-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ... RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association top ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of ... tissue and blood vessels provide greater detail than traditional x-rays, particularly of soft tissues and blood ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for children who cannot hold still. Motion will cause blurring of the images and degrade the quality ... lie still is reduced. Though the scanning itself causes no pain, there may be some discomfort from ...

  17. Combined bilateral idiopathic necrosis of the humerus and femur heads: Bone scan, X-ray, CT, and MRI findings

    International Nuclear Information System (INIS)

    Piepenburg, R.; Hahn, K.; Doll, G.; Grimm, J.

    1992-01-01

    Untreated aseptic bone necroses close to a joint commonly leads to severe secondary arthrosis and destruction of the joint within a short time. Therefore, only a diagnosis in an early stage of the disease offers the chance of a successful joint- preserving therapy. In cases of clinically suspected aseptic bone necrosis but still negative or doubtful X-ray findings, bone scans or MRI are reliable methods of verifying the diagnosis. (orig./MG) [de

  18. CT scan of pituitary adenomas

    International Nuclear Information System (INIS)

    Sakoda, K.; Mukada, K.; Yonezawa, M.; Matsumura, S.; Yoshimoto, H.; Mori, S.; Uozumi, T.

    1981-01-01

    CT scan is an extremely useful, almost harmless means of diagnosing pituitary adenomas. Growth hormone (GH)-secreting adenomas tend to have higher absorption coefficent in plain CT than the nonfunctioning and prolactin (PRL)-secreting adenomas. The absorption coefficent on contrast-enhanced CT does not identify the specific type of adenoma. Ring-like enhancement was observed in five nonfunctioning and four PRL-secreting adenomas with suprasellar extension, while cystic components were observed in four nonfunctioning and four PRL-secreting adenomas. In three of ten cases of PRL-secreting microadenomas, the site corresponding to the adenoma was not enhanced, whereas the normal pituitary was. A correlation exists between the size of PRL-secreting adenoma and the serum PRL level, but not between the size of GH-secreting adenomas and the serum GH level. (orig.)

  19. Delayed intracerebral hemorrhage as demonstrated by CT scanning

    International Nuclear Information System (INIS)

    Brunetti, J.; Zingesser, L.; Dunn, J.; Rovit, R.L.; Saint Vincent's Hospital and Medical Center, New York

    1979-01-01

    Three patients are presented who developed delayed intracerebral hematomas after head injury. Two patients had essentially negative CT scans on admission and developed intracerebral hematomas within 24 h after injury. They required surgical treatment and had fatal outcomes. The third patient presented with an epidural hematoma on CT scan, developed an intracerebral hematoma 48 h after evacuation of the epidural hematoma, and did well with conservative management. (orig.) [de

  20. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  1. CT scan findings in mild head trauma: a series of 2,000 patients Achados tomográficos no trauma cranioencefálico leve: análise de 2000 casos

    Directory of Open Access Journals (Sweden)

    Kelly C. Bordignon

    2002-06-01

    Full Text Available The present study describes the cranial computed tomography (CT scan findings of 2,000 cases of mild head trauma (HT in Curitiba, Southern Brazil. The mean age of the entire series was 30.8 ±19 years. The overall male to female ratio was 2:1. The most common causes of head injury were interpersonal aggression (17.9%, falls (17.4%, automobile accidents (16.2%, falls to the ground (13.1% and pedestrian injuries (13 %. Alcohol intoxication was associated with HT in 158 cases (7.9%. A normal CT scan was seen in 60.75% (1215 and an abnormal CT scan in 39.25% (785 of patients. Out of 785 abnormal CT scan, 518(65.9% lesions were related to HT. The most common CT scan HT related findings were: soft tissue swelling (8.9 %, skull fractures (4.3 %, intracranial and subgaleal hematomas (3.4% and 2.4 %, brain swelling (2 % and brain contusion (1.2%. Out of 785 abnormal CT scans, 267 (34.1% lesions were not related to head trauma. Incidental CT scan findings included brain atrophy (5.9%, one calcification (5.2% several calcifications (2.4% (probably neurocysticercosis in most cases, ischemic infarct (1.9% and leukoaraiosis (1.3%. These findings showed the importance of CT scan examination in mild head injuries. Further studies to identify mild HT patients at higher risk of significant brain injury are warranted in order to optimize its use.São descritos os achados de tomografia computadorizada craniana (TC de 2000 casos de trauma cranio-encefálico (TCE leve em Curitiba, Paraná. A idade média de toda série de pacientes foi 30,8 ± 19 anos. A razão homem/mulher foi 2:1. A causas mais comuns de TCE foram agressão interpessoal (17,9%, quedas de nível (17,4%, acidentes automobilísticos (16,2%, queda ao solo (13,1% e atropelamento (13%. Intoxicação por álcool foi um importante fator associado ao TCE e esteve presente em 158 casos (7,9% de 2000 pacientes. Uma TC normal ocorreu em 60,75% (1215 e uma TC anormal em 39,25% (785 dos pacientes. Das 785 TC

  2. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  3. Head injury: audit of a clinical guideline to justify head CT

    International Nuclear Information System (INIS)

    Haydon, Nicholas B.

    2013-01-01

    Head injury causes significant morbidity and mortality, and there is contention about which patients to scan. The UK National Health Service Clinical Guideline (CG) 56 provides criteria for selecting patients with clinically important brain injury who may benefit from a head CT scan, while minimising the radiation and economic burden of scanning patients without significant injury. This study aims to audit the documentation of the use of these guidelines in a busy UK trauma hospital and discusses the comparison with an Australian (New South Wales (NSW) ) head injury guideline. A retrospective cohort study of 480 patients presenting with head injury to the emergency department over 2 months was performed. The patient notes were assessed for documentation of each aspect of the clinical guidelines. Criteria were established to assess the utilisation of the CG 56. A database of clinical data was amalgamated with the head CT scan results for each patient. For the UK CG 56, 73% of the criteria were documented, with the least documented being 'signs of basal skull fracture' and 'amnesia of events'. Thirty-two per cent of patients received head CT and of these, 24% (37 patients) were reported to have pathology. Twenty-four patients underwent head CT without clinical justification being documented, none of which had reported pathology on CT. The study shows that the head injury guidelines are not being fully utilised at a major UK trauma hospital, resulting in 5% of patients being exposed to ionising radiation without apparent documented clinical justification. The NSW guideline has distinct differences to the CG 56, with a more complex algorithm and an absence of specific time frames for head CT completion. The results suggest a need for further education and awareness of head injury clinical guidelines.

  4. Clinical Symptoms of Minor Head Trauma and Abnormal Computed Tomography Scan

    Directory of Open Access Journals (Sweden)

    Maghsoudi

    2015-11-01

    Full Text Available Background Minor head trauma accounts for 70% to 90% of all head traumas. Previous studies stated that minor head traumas were associated with 7% - 20% significant abnormal findings in brain computed tomography (CT-scans. Objectives The aim of this study was to reevaluate clinical criteria of taking brain CT scan in patients who suffered from minor head trauma. Patients and Methods We enrolled 680 patients presented to an academic trauma hospital with minor head trauma in a prospective manner. All participants underwent brain CT scan if they met the inclusion criteria and the results of scans were compared with clinical examination finding. Results Loss of consciousness (GCS drop or amnesia was markedly associated with abnormal brain CT scan (P < 0.05. Interestingly, we found 7 patients with normal clinical examination but significant abnormal brain CT scan. Conclusions According to the results of our study, we recommend that all patients with minor head trauma underwent brain CT scan in order not to miss any life-threatening head injuries.

  5. Evaluation strategies in CT scanning

    DEFF Research Database (Denmark)

    In this talk, dimensional measurement results using different measuring strategies applied in different inspection software packages for volume and surface data analysis are presented. The influence of the strategy on the dimensional measurement is determined by calculating the measurement...... uncertainty. This investigation includes measurements of two industrial items, an aluminum pipe connector and a plastic toggle, a hearing aid component. These are measured using a commercial CT scanner. Traceability is transferred using tactile and optical coordinate measuring machines, which are used...

  6. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  7. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  8. Detailed Review of CT Scans Aids Assessment of the Airway in ...

    African Journals Online (AJOL)

    Two cases are presented that illustrate the importance of information gained from CT scans of the head and neck taken in patients presenting for maxillo-facial surgery. The first case involved a 25 year old with a massive tumour filling his mouth. Pre-operative assessment was done without reviewing the CT scans of his ...

  9. Variations in the intensive use of head CT for elderly patients with hemorrhagic stroke.

    Science.gov (United States)

    Bekelis, Kimon; Fisher, Elliott S; Labropoulos, Nicos; Zhou, Weiping; Skinner, Jonathan

    2015-04-01

    To investigate the variability in head computed tomographic (CT) scanning in patients with hemorrhagic stroke in U.S. hospitals, its association with mortality, and the number of different physicians consulted. The study was approved by the Committee for the Protection of Human Subjects at Dartmouth College. A retrospective analysis of the Medicare fee-for-service claims data was performed for elderly patients admitted for hemorrhagic stroke in 2008-2009, with 1-year follow-up through 2010. Risk-adjusted primary outcome measures were mean number of head CT scans performed and high-intensity use of head CT (six or more head CT scans performed in the year after admission). We examined the association of high-intensity use of head CT with the number of different physicians consulted and mortality. A total of 53 272 patients (mean age, 79.6 years; 31 377 women [58.9%]) with hemorrhagic stroke were identified in the study period. The mean number of head CT scans conducted in the year after admission for stroke was 3.4; 8737 patients (16.4%) underwent six or more scans. Among the hospitals with the highest case volume (more than 50 patients with hemorrhagic stroke), risk-adjusted rates ranged from 8.0% to 48.1%. The correlation coefficient between number of physicians consulted and rates of high-intensity use of head CT was 0.522 (P mortality was found for patients undergoing six or more head CT scans (odds ratio, 0.84; 95% confidence interval: 0.69, 1.02). High rates of head CT use for patients with hemorrhagic stroke are frequently observed, without an association with decreased mortality. A higher number of physicians consulted was associated with high-intensity use of head CT. © RSNA, 2014 Online supplemental material is available for this article.

  10. Prognostic role of metabolic parameters of {sup 18}F-FDG PET-CT scan performed during radiation therapy in locally advanced head and neck squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Min, Myo; Forstner, Dion [Liverpool Hospital, Cancer Therapy Centre, Liverpool, NSW (Australia); University of New South Wales, Sydney, NSW (Australia); Ingham Institute of Applied Medical Research, Liverpool, NSW (Australia); Lin, Peter; Shon, Ivan Ho; Lin, Michael [University of New South Wales, Sydney, NSW (Australia); Liverpool Hospital, Department of Nuclear Medicine and Positron Emission Tomography, Liverpool, NSW (Australia); University of Western Sydney, Sydney, NSW (Australia); Lee, Mark T. [Liverpool Hospital, Cancer Therapy Centre, Liverpool, NSW (Australia); University of New South Wales, Sydney, NSW (Australia); Bray, Victoria; Fowler, Allan [Liverpool Hospital, Cancer Therapy Centre, Liverpool, NSW (Australia); Chicco, Andrew [Liverpool Hospital, Department of Nuclear Medicine and Positron Emission Tomography, Liverpool, NSW (Australia); Tieu, Minh Thi [Calvary Mater Newcastle, Department of Radiation Oncology, Newcastle, NSW (Australia); University of Newcastle, Newcastle, NSW (Australia)

    2015-12-15

    To evaluate the prognostic value of {sup 18}F-FDG PET-CT performed in the third week (iPET) of definitive radiation therapy (RT) in patients with newly diagnosed locally advanced mucosal primary head and neck squamous-cell-carcinoma (MPHNSCC). Seventy-two patients with MPHNSCC treated with radical RT underwent staging PET-CT and iPET. The maximum standardised uptake value (SUV{sub max}), metabolic tumour volume (MTV) and total lesional glycolysis (TLG) of primary tumour (PT) and index node (IN) [defined as lymph node(s) with highest TLG] were analysed, and results were correlated with loco-regional recurrence-free survival (LRFS), disease-free survival (DFS), metastatic failure-free survival(MFFS) and overall survival (OS), using Kaplan-Meier analysis. Optimal cutoffs (OC) were derived from receiver operating characteristic curves: SUV{sub max-PT} = 4.25 g/mL, MTV{sub PT} = 3.3 cm{sup 3}, TLG{sub PT} = 9.4 g, for PT, and SUV{sub max-IN} = 4.05 g/mL, MTV{sub IN} = 1.85 cm{sup 3} and TLG{sub IN} = 7.95 g for IN. Low metabolic values in iPET for PT below OC were associated with statistically significant better LRFS and DFS. TLG was the best predictor of outcome with 2-year LRFS of 92.7 % vs. 71.1 % [p = 0.005, compared with SUV{sub max} (p = 0.03) and MTV (p = 0.022)], DFS of 85.9 % vs. 60.8 % [p = 0.005, compared with SUV{sub max} (p = 0.025) and MTV (p = 0.018)], MFFS of 85.9 % vs. 83.7 % [p = 0.488, compared with SUV{sub max} (p = 0.52) and MTV (p = 0.436)], and OS of 81.1 % vs. 75.0 % [p = 0.279, compared with SUV{sub max} (p = 0.345) and MTV (p = 0.512)]. There were no significant associations between the percentage reduction of primary tumour metabolic parameters and outcomes. In patients with nodal disease, metabolic parameters below OC (for both PT and IN) were significantly associated with all oncological outcomes, while TLG was again the best predictor: LRFS of 84.0 % vs. 55.3 % (p = 0.017), DFS of 79.4 % vs. 38.6 % (p = 0.001), MFFS 86.4 % vs. 68.2 % (p = 0

  11. CT scan of bacterial and aseptic meningitis

    International Nuclear Information System (INIS)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role. (author)

  12. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  13. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  14. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  15. A new objective method for CT triage after minor head injury--serum S100B

    DEFF Research Database (Denmark)

    Undén, Johan; Rommer, Bertil Roland

    2009-01-01

    The risk of acute intracranial complication after minor head injury (MHI) is low. Despite this, a computed tomography (CT) scan is generally recommended for all patients following MHI. Admission for clinical observation is a secondary management option when a CT scan is unavailable or is judged i...

  16. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  17. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  18. Developing optimized CT scan protocols: Phantom measurements of image quality

    International Nuclear Information System (INIS)

    Zarb, Francis; Rainford, Louise; McEntee, Mark F.

    2011-01-01

    Purpose: The increasing frequency of computerized tomography (CT) examinations is well documented, leading to concern about potential radiation risks for patients. However, the consequences of not performing the CT examination and missing injuries and disease are potentially serious, impacting upon correct patient management. The ALARA principle of dose optimization must be employed for all justified CT examinations. Dose indicators displayed on the CT console as either CT dose index (CTDI) and/or dose length product (DLP), are used to indicate dose and can quantify improvements achieved through optimization. Key scan parameters contributing to dose have been identified in previous literature and in previous work by our group. The aim of this study was to optimize the scan parameters of mA; kV and pitch, whilst maintaining image quality and reducing dose. This research was conducted using psychophysical image quality measurements on a CT quality assurance (QA) phantom establishing the impact of dose optimization on image quality parameters. Method: Current CT scan parameters for head (posterior fossa and cerebrum), abdomen and chest examinations were collected from 57% of CT suites available nationally in Malta (n = 4). Current scan protocols were used to image a Catphan 600 CT QA phantom whereby image quality was assessed. Each scan parameter: mA; kV and pitch were systematically reduced until the contrast resolution (CR), spatial resolution (SR) and noise were significantly lowered. The Catphan 600 images, produced by the range of protocols, were evaluated by 2 expert observers assessing CR, SR and noise. The protocol considered as the optimization threshold was just above the setting that resulted in a significant reduction in CR and noise but not affecting SR at the 95% confidence interval. Results: The limit of optimization threshold was determined for each CT suite. Employing optimized parameters, CTDI and DLP were both significantly reduced (p ≤ 0.001) by

  19. CT analysis of missile head injury

    International Nuclear Information System (INIS)

    Besenski, N.; Jadro-Santel, D.; Jelavic-Koic, F.; Pavic, D.; Mikulic, D.; Glavina, K.; Maskovic, J.

    1995-01-01

    Between August 1991 and December 1992, CT was performed in 154 patients who had suffered missile head injury during the war in the Republic of Croatia. In 54% CT was performed 1-24 h after injury, and in 27% follow-up CT was also obtained. The wounds were penetrating, tangential or perforating (45%, 34% and 21%, respectively). Haemorrhage was the most frequent lesion in the brain (84%). Follow-up CT evolution of haemorrhage, oedema, cerebritis, abscess, secondary vascular lesions, necrosis, encephalomalacia and hydrocephalus. The most dynamic changes occurred 7-14 days after injury. In 14% of cases, deep cerebral lesions were found in the corpus callosum, septum pellucidum periventricular region and pons, although bone and shell fragments were in a different part of the brain parenchyma. Such lesions were found in penetrating injuries only. CT proved very useful for assessing the extent and type of lesions. Although different mechanisms of brain damage in missile head injury are known, here they are, to the best of our knowledge, shown for the first time by CT. (orig.)

  20. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  1. Serial CT scannings in herpes simplex encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, M.; Sawada, T.; Kuriyama, Y.; Kinugawa, H.; Yamaguchi, T. (National Cardivascular Center, Osaka (Japan))

    1981-10-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemiparesis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis.

  2. Serial CT scannings in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Fukushima, Masashi; Sawada, Tohru; Kuriyama, Yoshihiro; Kinugawa, Hidekazu; Yamaguchi, Takenori

    1981-01-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemipare sis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis. (author)

  3. CT scanning in patients with amputated legs

    International Nuclear Information System (INIS)

    Huebener, K.H.; Ahlemann, L.M.

    1981-01-01

    CT scanning after above-knee amputation and below-knee amputation helps to determine the calcium salt content of the examined bones, and to differentiate changes in the surrounding soft parts. By comaring the sides, it is quite easy to detect osteoporotic changes shortly after amputation which would otherwise remain undetected by X-ray film examination. It is equally easy to verify muscular changes, whereas characteristic changes in density allow to determine the share of vacant fat in muscular atrophy. Initial examinations proved the usefulness of CT diagnosis for early detection of dystrophic osseous and muscular changes and also show the possibilities of early therapy control of dystrophy treatment. (orig.) [de

  4. Computed tomography scan optimization using head phantom and radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P., E-mail: lorena.cfernandes@hotmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: pridili@gmail.com, E-mail: apmourao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro de Imagem Molecular do INCT-Medicina Molecular (CIMol/UFMG) Belo Horizonte (Brazil); Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  5. Computed tomography scan optimization using head phantom and radiochromic films

    International Nuclear Information System (INIS)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P.

    2017-01-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  6. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  7. Efficacy of Breast Shielding During CT of the Head

    International Nuclear Information System (INIS)

    Brnic, Z.; Vekic, B.; Hebrang, A.; Anic, P.

    2003-01-01

    The use of computerized tomography (CT) is rapidly increasing in last two decades, and this method has become the major non-natural source of radiation exposure to the population. CT examinations delivers to the patients more radiation than all other imaging techniques, and contribute disproportionately to the collective dose; in Britain it has been estimated that 4% of diagnostic radiology procedures are CT examinations, being responsible for approximately 40% of the total annual collective dose. Breast doses are high in CT examinations with breasts in scanning planes, being not insignificant also when breasts are exposed only to scatter radiation. Breast doses received through scatter radiation during head CT may account for up to one-fifth of an average mammographic dose per one view. Whilst the possibilities of reduction of radiation load to organs lying in CT scanning planes are limited, the tissues outside the primary beam should be protected against scatter whenever it does not sacrifice image quality. Lead shielding results in significant reduction of external scatter to radiosensitive superficial organs in many diagnostic procedures. The published studies of breast shielding against scatter radiation in diagnostic radiology are scanty, only the later one dealing particularly with breast shielding during head CT examination. The aims of this study were to investigate in vivo the levels of breast exposure to scatter radiation in head CT examination and the dependence of breast exposure upon body constitution. We tried to estimate the efficacy of external lead shielding as a mean of breast dose reduction, and to determine how much radiation reaches the organ from outside, in comparison to radiation load caused through internal scatter. We conclude that, although the level of breast radiation exposure during head CT examinations is generally low, shielding of the breasts with lead apron will further reduce the doses. However is the effect of shielding limited

  8. CT-scanning in otolaryngology, 2

    International Nuclear Information System (INIS)

    Kusakari, Jun; Endo, Satomi; Hara, Akira

    1982-01-01

    Combined computerized tomography-sialography was performed in 28 patients with parotid tumors. Sialography was performed in the usual fashion. After confirming the presence of the contrast material within the parotid gland by X-ray, 4 to 5 scannings were done at the width of 10 mm below Repid's base line. With this procedure, the parotid gland was clearly demonstrated and the location of the tumor was shown as a shadow defect. Although the nature of the tumor, especially whether it was malignant or benign was difficult to predict, the CT-findings regarding the size and location of the tumor were completely coincident with the operative findings in all the cases. Accurate appraisal of the relation between the tumor and the facial nerve was possible in all but two cases. The preoperative information obtained from CT-scanning is extremely useful in the case of parotid tumor surgery. (author)

  9. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  10. Evolution of traumatic intracerebral hematoma. Analysis of sequential CT scans since per-acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Nagaseki, Yoshishige; Horikoshi, Satoru [Gunma Univ., Maebashi (Japan). School of Medicine; Tamura, Masaru

    1984-05-01

    To clarify the evolution of traumatic intracerebral hematoma (TICH), initial computerized tomography (CT) scans of 28 TICH cases performed within one hour after head trauma were studied along with their follow-up CT scans. They were classified into the following two groups; per-acute group included seven cases in which TICH was completed on the initial CT scans taken within one hour after head injury and acute group included 21 cases in which the initial CT scans revealed isodensity or high density spot and repeat CT scans disclosed TICH by 48 hours after injury. In the per-acute group, initial CT scans showed a homogeneous, well defined, and high density mass (1.5-6.5 cm in diameter). In sequential CT scans of the three cases, the hematoma did not increase but spontaneously disappeared. Other four cases died early after head trauma. Their initial CT scans revealed a large high density mass (3-6.5 cm in diameter) combined with other extracerebral hemorrhages. In the acute group, initial CT scans demonstrated isodensity or high density spot and sequential CT scans showed mottled appearance of salt and pepper appearance, and after a while showed fusion of small high density areas to become a massive high density area (contusional hematoma) by 48 hours after injury. In six cases of this group, the contusional hematoma was removed within 24 hours after injury and in one case at 3.5 days. In other 14 cases, the hematomas shrank or disappeared spontaneously. From these results, it was considered that evolution of TICH's were classified into the two groups; per-acute group resulting from rupture of vessels and acute group resulting from contusion.

  11. Rhabdomyosarcoma of children in the head and neck : CT and MR finding

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, In One; Kim, Woo Sun; Han, Sang Wook; Kim, Hyun Beom; Yeon, Myung Mo

    1998-01-01

    The purpose of this study is to evaluate radiologic findings of rhabdomyosarcoma of children in the head and neck concerning the origin, morphologic characteristics, extent, and the route of intracranial extension on CT and MR. Twenty cases of pathologically proven rhabdomyosarcoma were analyzed. Fifteen CT scans (postcontrast CT (n=13), precontrast CT (n=2)) and eleven MR scans were obtained. Postcontrast MR scans were performed in the ten cases. Six cases had CT and MR scans. Nine cases had only CT scan and five had only MR scans. We retrospectively analyzed the origin, morphologic characteristics (attenuation, signal intensity, margin), extent,intracranial extension, route and clinical staging of rhabdomyosarcoma on CT and MR scans. Rhabdomyosarcoma of children in the head and neck tends to show relatively severe bony destruction of skull base and various intracranial extension routes can be helpful radiologic findings on the CT or MR scan although its CT density or signal intensity of MR was not specific. And it is peculiar that infratempral fossa was the most common site of origin of rhabdomyosarcoma. (author). 28 refs., 2 tabs., 5 figs

  12. Brain CT findings in head injury with skull fracture

    International Nuclear Information System (INIS)

    Jeong, In Tae; Lee, Hae Kyung; Chung, Mi Kyung; Kwon, Kwi Hyang; Kim, Ki Jeong

    1982-01-01

    CT has revolutionized the evaluation and management of patients with head injuries. CT in non-invasion and rapidly provides accurate information regarding the presence, extent and nature of intracranial lesions resulting from trauma. We have reviewed the CT scans of 114 patients, who got head injury with confirmed to skull fracture in plain films. The results were as follows: 1. Of all cases, traffic accident was the most frequent cause and in children fall down was more than 50%. 2. Compound linear fracture was the most frequent type fractures in plain skull film.3. Of all 114 cases, epidural hematoma was 16%, subdural hematoma was 18.4%, intracerebral hematoma was 14.4%, subdural hygroma was 2.4%, normal finding was 50%. 4. Mortality rate was 13.2%. 5. Fracture was detected by CT about 28.9%, depression fracture was more easily detected in CT. 6. Incidence rate of counter coup lesion was 14.9% and mortality rate was higher than same site lesion. 7. The shape of epidural hematoma was biconvex in 75%, planoconvex in 25%. 8. The shape of subdural hematoma was cresentic shape 82.6%, biconvex shape 8.7%, planoconvex shape 8.7%

  13. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  14. Postmortem CT of severe head injuries

    International Nuclear Information System (INIS)

    Tamura, Masaru; Tsukahara, Yoshio; Nagaseki, Yoshishige; Horikoshi, Satoru; Yodonawa, Masahiko

    1983-01-01

    CT findings of fatal head injuries were analysed for the cause of death. Postmortem CT examinations were undertaken on 14 cases who died before reaching the hospital or shortly after arrival at the hospital (immediate death group). CT were also examined in non-operative 20 cases who were comatose and who died within 24 hours after severe head injuries (early death group). In the immediate death group, the following findings were demonstrated: a huge amount of free intracranial and intraventricular air in 8 cases; traumatic basal subarachnoid hemorrhage in 3 cases; a mixture of pneumocephalus and subarachnoid hemorrhage in 2 cases, and intracranial hematoma in 1 case. In the early death group: a mixture of pneumocephalus and subarachnoid hemorrhage in 2 cases; traumatic subarachnoid hemorrhage in 5 cases; intracranial hematoma in 11 cases, and brain contusion in 2 cases. The huge amount of intracranial free air due to the severe fracture of the skull base will make the CNS collapse immediately. Basal subarachnoid hemorrhage with signs of brain-stem injuries may result in instantaneous death. Acute subdural hematoma with contusion and edema in elderly patients was the most frequent cause of death in the early death group. (author)

  15. Clinical value of computerized tomography scanning in severe head injury

    International Nuclear Information System (INIS)

    Kobayashi, Shiro; Yano, Masami; Otsuka, Toshibumi; Nakazawa, Shozo

    1982-01-01

    Serial computerized tomography (SCT) was performed on 138 patients suffering from severe head injuries (8 or less on the Glasgow Coma Scale). Standard practice called for scans to be done upon admission (within hours of the injury), and after 1, 3, 7 days and 1 month. Subsequent CT's depended on the patient's condition. Clinical results at the time of discharge were graded according to the Glasgow Outcome Scale. Patients who died, were in a persistent vegetative state, or were severely disabled were considered to have a ''bad outcome''. On the other hand, patients who were somewhat disabled or made good recoveries were considered to have a ''good outcome''. During the serial CT scan, there were new findings (not visualized on the initial CT but appearing on subsequent ones) in 91 of the 138 patients. These new findings were classified as follows; 1) decreased density collection in the subdural space (DDC), 2) ventricular dilation (VD), 3) intracerebral hematoma (ICH), 4) intraventricular hemorrhage (IVH), 5) extracerebral hematoma (ECH), 6) edema (E), 7) infarction (I). We defined ICH, IVH, ECH, E and I as new lesions. Of the 60 patients with new lesions 12 had good outcomes and 48 had poor outcomes. There were 78 patients who did not have any new lesions, 60 with good outcomes and 18 with poor outcomes. A significant correlation was found between good outcomes and the absence of new lesions, and between bad outcomes and the development of new lesions (p 2 = 44.038). We conclude that SCT can help predict the outcome with severe head injury patients and may be very important in their examination and care. (J.P.N.)

  16. High speed printing with polygon scan heads

    Science.gov (United States)

    Stutz, Glenn

    2016-03-01

    To reduce and in many cases eliminate the costs associated with high volume printing of consumer and industrial products, this paper investigates and validates the use of the new generation of high speed pulse on demand (POD) lasers in concert with high speed (HS) polygon scan heads (PSH). Associated costs include consumables such as printing ink and nozzles, provisioning labor, maintenance and repair expense as well as reduction of printing lines due to high through put. Targets that are applicable and investigated include direct printing on plastics, printing on paper/cardboard as well as printing on labels. Market segments would include consumer products (CPG), medical and pharmaceutical products, universal ID (UID), and industrial products. In regards to the POD lasers employed, the wavelengths include UV(355nm), Green (532nm) and IR (1064nm) operating within the repetition range of 180 to 250 KHz.

  17. Implementation of dual energy CT scanning

    International Nuclear Information System (INIS)

    Marshall, W.; Hall, E.; Doost-Hoseini, A.; Alvarez, R.; Macovski, A.; Cassel, D.

    1984-01-01

    A prereconstruction method for dual energy (PREDECT) analysis of CT scans is described. In theory, this method can (a) eliminate beam hardening and produce an accuracy comparable with monoenergetic scans and (b) provide the effective atomic number and electron density of any voxel scanned. The implementation proves these statements and eliminates some of the objectionable noise. A phantom was constructed with a cylindrical sleeve-like compartment containing known amounts of high atomic number material simulating a removable skull. Conventional scans, with and without this beam hardener, were done of a water bath containing tubes of high electron and high atomic number material. Dual energy scans were then done for PREDECT. To increase the effective separation of the low and high energy beams by using more appropriate tube filtration, a beam filter changer was fabricated containing erbium, tungsten, aluminum, and steel. Erbium, tungsten, and steel were used at high energy and aluminum, steel, and erbium at low energy for data acquisition. The reconstructions were compared visually and numerically for noise levels with the original steel only filtration. A decrease was found in noise down to approximately one-half the prior level when erbium/aluminum or tungsten/aluminum replaced the steel/steel filter. Erbium and tungsten were equally effective. Steel/erbium and steel/aluminum also significantly reduced image noise. The noise in the photoelectric (P) and Compton (C) images is negatively correlated. At any pixel, if the noise is positive in the P image, it is most probably negative in the C. Using this fact, the noise was reduced by postreconstruction processing

  18. Portable head computed tomography scanner--technology and applications: experience with 3421 scans.

    Science.gov (United States)

    Carlson, Andrew P; Yonas, Howard

    2012-10-01

    The use of head computed tomography (CT) is standard in the management of acute brain injury; however, there are inherent risks of transport of critically ill patients. Portable CT can be brought to the patient at any location. We describe the clinical use of a portable head CT scanner (CereTom: NeuroLogica: Danvers, MA) that can be brought to the patient's bedside or to other locations such as the operating room or angiography suite. Between June of 2006 and December of 2009, a total of 3421 portable CTs were performed. A total of 3278 (95.8%) were performed in the neuroscience intensive care unit (ICU) for an average of 2.6 neuroscience ICU CT scans per day. Other locations where CTs were performed included other ICUs (n = 97), the operating room (n = 53), the emergency department (n = 1), and the angiography suite (n = 2). Most studies were non-contrasted head CT, though other modalities including xenon/CT, contrasted CT, and CT angiography were performed. Portable head CT can reliably and consistently be performed at the patient's bedside. This should lead to decreased transportation-related morbidity and improved rapid decision making in the ICU, OR, and other locations. Further studies to confirm this clinical advantage are needed. Copyright © 2011 by the American Society of Neuroimaging.

  19. CT SCAN EVALUATION OF PULMONARY NODULE

    Directory of Open Access Journals (Sweden)

    A. Ravi Kumar

    2016-06-01

    Full Text Available BACKGROUND Lung carcinomas are quite commonly diagnosed. Thanks to the ever increasing smokers’ population. Majority of the city dwellers are at a higher risk of having this disease when compared to the village counterparts. The stigma through which the person and the family have to undergo before confirming the diagnosis is enormous. So the radiographic methods of diagnosing the malignancies have to improve. Before confirming the diagnosis, the radiologists, the treating physicians should be somewhat confident about the diagnosis so as to prepare the patients and their relatives for the most probable diagnosis before the confirmatory report. The confirmatory procedures include the PET scan and the Histopathology. Both are time consuming procedures and in an economy like ours, finding a PET scanning centre is rather difficult. So the most probable diagnosis has to be thought of using minimal resource. This study puts in a sincere effort to understand and evaluate the pulmonary nodule when identified by a CT scan. This paper is intended to help the practicing radiologists and also make life easy for a practicing physician to identify correctly the lesions and also help the patients to prevent further progression of the disease. METHODS The study was a cross-sectional study. The sample size of the study consisted of thirty patients. CT scan was done in thirty patients who were identified to have lung nodules either by other mode of radiological studies or first time identified in a CT scan itself. The study was conducted in Fathima Institute of Medical Sciences, Kadapa. The study was conducted from 2014 to 2015. RESULT Non-solid nodules were more in number when compared to the solid nodules. All the non-solid nodules were confirmed to be adenomas. Eighty percent of the nodules which were more than 8 mm in size were confirmed to be malignant. One hundred percent of the spiculated border on CT was confirmed to be malignant. In the present study

  20. Full-Body CT Scans - What You Need to Know

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Full-Body CT Scans - What You Need to Know Share ... if you are thinking of having a whole-body screening: Whole-body CT screening has not been ...

  1. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  2. Differential Aging Signals in Abdominal CT Scans.

    Science.gov (United States)

    Orlov, Nikita V; Makrogiannis, Sokratis; Ferrucci, Luigi; Goldberg, Ilya G

    2017-12-01

    Changes in the composition of body tissues are major aging phenotypes, but they have been difficult to study in depth. Here we describe age-related change in abdominal tissues observable in computed tomography (CT) scans. We used pattern recognition and machine learning to detect and quantify these changes in a model-agnostic fashion. CT scans of abdominal L4 sections were obtained from Baltimore Longitudinal Study of Aging (BLSA) participants. Age-related change in the constituent tissues were determined by training machine classifiers to differentiate age groups within male and female strata ("Younger" at 50-70 years old vs "Older" at 80-99 years old). The accuracy achieved by the classifiers in differentiating the age cohorts was used as a surrogate measure of the aging signal in the different tissues. The highest accuracy for discriminating age differences was 0.76 and 0.72 for males and females, respectively. The classification accuracy was 0.79 and 0.71 for adipose tissue, 0.70 and 0.68 for soft tissue, and 0.65 and 0.64 for bone. Using image data from a large sample of well-characterized pool of participants dispersed over a wide age range, we explored age-related differences in gross morphology and texture of abdominal tissues. This technology is advantageous for tracking effects of biological aging and predicting adverse outcomes when compared to the traditional use of specific molecular biomarkers. Application of pattern recognition and machine learning as a tool for analyzing medical images may provide much needed insight into tissue changes occurring with aging and, further, connect these changes with their metabolic and functional consequences. Published by Elsevier Inc.

  3. CT and MRI matching for radiotherapy planning in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rasch, C; Keus, R; Touw, A; Lebesque, J; Van Herk, M [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands)

    1995-12-01

    The objective of this study was to evaluate the impact of matched CT and MRI information on target delineation in radiotherapy planning for head and neck tumors. MRI images of eight patients with head and neck cancer in supine position, not necessarily obtained in radiotherapy treatment position were matched to the CT scans made in radiotherapy position using automatic three-dimensional chamfer-matching of bony structures. Four independent observers delineated the Gross Tumor Volume (GTV) in CT scans and axial and sagittal MR scans. The GTV`s were compared, overlapping volumes and non-overlapping volumes between the different datasets and observers were determined. In all patients a good match of CT and MRI information was accomplished in the head region. The combined information provided a better visualisation of the GTV, oedema and normal tissues compared with CT or MRI alone. Determination of overlapping and non-overlapping volumes proved to be a valuable tool to measure uncertainties in the determination of the GTV. CT-MRI matching in patients with head and neck tumors is feasible and makes a more accurate irradiation with higher tumor doses and less normal tissue complications possible. Remaining uncertainties in the determination of the GTV can be quantified using the combined information of MRI and CT.

  4. CT scan for the diagnosis of maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Kimura, Yo; Kato, Isao; Aoyagi, Masaru; Kikuchi, Akira; Koike, Yoshio; Suzuki, Hachiro.

    1984-01-01

    A comparative study between the conventional radiological examination and the computed tomographical examination for the diagnosis of maxillary sinus carcinoma was done. CT scan has been more appreciated to detect the tumor invasion in the pterygopalatine fossa, orbit, posterior ethmoid sinus and skull base than the conventional examination. CT scan was most usefull for the determination of size and location of the tumor. The prognosis by the stage-grouping was significantly separated by the new classification with CT scan. Therefore, new TNM classification of maxillary sinus carcinoma with CT scan should be taken into account. (author)

  5. Correlation between image quality of CT scan and amount of intravenous contrast media

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Choi, Dae Seob; Kim, Seung Hyup; Han, Joon Koo; Choi, Byung Ihn; Im, Jung Gi; Han, Moon Hee; Chang, Kee Hyun; Kim, Jong Hyo; Han, Man Chung

    1993-01-01

    A blind, comparative clinical study was performed prospectively to examine the correlation between image quality of CT scan in terms of contrast enhancement effect and amount of intravenous contrast media. A total of 357 patients were randomized into two groups. Ionic high-osmolality contrast media (68% meglumine ioglicate) was administered intravenously as 100 ml bolus in one group and as 50 ml bolus in the other group. Statistically significant differences of image quality were found in CT scans of the brain, head and neck, chest and abdomen (p 0.05). We suggest that amount of contrast media may be reduced in pelvis CT without significant degradation of image quality

  6. CT findings and outcome in head injury

    Energy Technology Data Exchange (ETDEWEB)

    Yamaura, Akira

    1984-12-01

    CT findings and outcome were discussed in head injuries. Parenchymal findings were classified into 5 categories; ''normal'', ''hemispheric (isodense) swelling'', ''hemorrhagic lesions'', ''diffuse cerebral swelling'', and ''low density''. The worst outcome (73% mortality) was seen in ''hemispheric swelling''. This abnormality was quite often associated with acute subdural hematoma. Multiple ''hemorrhagic lesions'' were associated with much poorer outcome than single lesions. The older groups had more acute subdural hematomas and more ''hemorrhagic lesions''. And ''hemorrhagic lesions'' were more often multiple and larger in the older group. (author).

  7. Ultrafast CT scanning of an oak log for internal defects

    Science.gov (United States)

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  8. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  9. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  10. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  11. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  12. Clinical and CT scan pictures of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Singounas, E.G.; Krassanakis, K.; Karvounis, P.C. (Evangelismos Hospital, Athens (Greece))

    1982-01-01

    The clinical presentations and CT scan pictures of four patients harbouring big cysticercus cysts are described. The value of CT scanning in detecting these cysts is emphasized, and also the fact that these cysts can behave as space-occyping lesions, which must be differentiated from other cystic formations.

  13. Combined bilateral idiopathic necrosis of the humerus and femur heads: Bone scan, X-ray, CT, and MRI findings. Kombinierte beidseitige idiopathische Nekrose der Humerus- und Femurkoepfe: Skelettszintigraphie, Roentgen-, CT- und MRT-Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Piepenburg, R.; Hahn, K. (Mainz Univ. (Germany). Klinik fuer Nuklearmedizin); Doll, G. (Mainz Univ. (Germany). Klinik fuer Roentgendiagnostik); Grimm, J. (Mainz Univ. (Germany). Orthopaedische Klinik)

    1992-12-01

    Untreated aseptic bone necroses close to a joint commonly leads to severe secondary arthrosis and destruction of the joint within a short time. Therefore, only a diagnosis in an early stage of the disease offers the chance of a successful joint- preserving therapy. In cases of clinically suspected aseptic bone necrosis but still negative or doubtful X-ray findings, bone scans or MRI are reliable methods of verifying the diagnosis. (orig./MG).

  14. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  15. Spinal CT scan, 1. Cervical and thoracic spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ. (Japan))

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections.

  16. The use of the eyes protection for dose reduction in CT scans of skull

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Silva, Teogenes A.; Alonso, Thessa C.

    2013-01-01

    The technique for imaging the brain scans of the skull by computed tomography (CT) scanning is the volume bounded by the foramen magnum and the apex of the skull. The lenses are radiosensitive tissues and CT scans of the head deposited significant doses on them, since they are in the region of incidence of the primary beam of X-rays. Thus, the variation of the dose deposited in the crystalline skull CT scans for diagnostic imaging of the brain was investigated. Cranial scans were performed using the acquisition protocol routine with or without the use of bismuth to shield the eyes. To carry out the scans we used a male anthropomorphic phantom, Alderson Rando model and dosimeters (TLD-100) were used to record the doses. These TLDs were used to record specific doses internally to the phantom in specific organs (crystalline, pituitary, thyroid, spinal cord and breasts). The scans were performed on a GE machine, model 64 Discovery channels. The data obtained allowed to observe the variation of dose in organs. The highest dose was recorded in the lens (26,18 mGy), followed by spinal cord (17,79 mGy). Comparing the doses of the two scans it was significant variation in the crystal. Scan using bismuth shield generated smaller doses in the eyes and in the eyes occurred the higher dose reduction, about 37%. The results may contribute to spread a suitable procedure for the optimization of CT scans of the skull

  17. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    International Nuclear Information System (INIS)

    Hinzpeter, Ricarda; Sprengel, Kai; Wanner, Guido A.; Mildenberger, Peter; Alkadhi, Hatem

    2017-01-01

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  18. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    Energy Technology Data Exchange (ETDEWEB)

    Hinzpeter, Ricarda, E-mail: Ricarda.Hinzpeter@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland); Sprengel, Kai, E-mail: Kai.Sprengel@usz.ch [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Wanner, Guido A., E-mail: Guido.Wanner@sbk-vs.de [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Department of General Surgery, Schwarzwald-Baar Klinikum, University of Freiburg, Klinikstr. 11, D-78052 Villingen-Schwenningen (Germany); Mildenberger, Peter, E-mail: peter.mildenberger@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, University Hospital of Mainz, Langenbeckstr. 1, D-55131 Mainz (Germany); Alkadhi, Hatem, E-mail: hatem.alkadhi@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland)

    2017-03-15

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  19. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  20. 3D dosimetry by optical-CT scanning

    Science.gov (United States)

    Oldham, Mark

    2006-12-01

    The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (within 7% dose-difference or 4mm distance-to-agreement) evaluated at a half-dozen points and a single axial plane. The question that arises from this disturbing finding is - what percentage of institutions would have failed if a comprehensive 3D measurement had been feasible, rather than measurements restricted to the central film-plane and TLD points? This question can only be adequately answered by a comprehensive 3D-dosimetry system, which presents a compelling argument for its development as a clinically viable low cost dosimetry solution. Optical-CT dosimetry is perhaps the closest system to providing such a comprehensive solution. In this article, we review the origins and recent developments of optical-CT dosimetry systems. The principle focus is on first generation systems known to have highest accuracy but longer scan times.

  1. CT detection of occult pneumothorax in head trauma

    International Nuclear Information System (INIS)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.; Bahr, A.L.; Thomas, F.

    1984-01-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothorax during subsequent mechanical ventilation or emergency surgery under general anesthesia

  2. CT detection of occult pneumothorax in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.; Bahr, A.L.; Thomas, F.

    1984-11-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothorax during subsequent mechanical ventilation or emergency surgery under general anesthesia.

  3. Role of CT scan in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Salem, O.A.; Khasawneh, M.

    2007-01-01

    To evaluate the diagnostic accuracy of the spiral-CT in patients with clinically suspected acute appendicitis. A total of 124 patients referred for CT scan with suspected appendicitis between January 2005 and October 2006 were assessed for the appendiceal size and the presence of signs of appendicitis. The findings were correlated with surgical histopathology. CT scan had a sensitivity of 95 percent and a specifity of 93 percent and an overall accuracy of 92 percent. The use of spiral CT in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to significant improvement in the preoperative diagnosis. (author)

  4. Computed Tomography (CT) Scans and Cancer

    Science.gov (United States)

    ... Reporting & Auditing Grant Transfer Grant Closeout Contracts & Small Business Training Cancer Training at NCI (Intramural) Resources for ... companies (and Medicare) do not currently reimburse the costs of this procedure. Also, because CT ... the effectiveness of low-dose helical CT for lung cancer ...

  5. Initial experience of Fag-PET/CT guided Imr of head-and-neck carcinoma

    International Nuclear Information System (INIS)

    Wang Dian; Schultz, Christopher J.; Jursinic, Paul A.; Bialkowski, Mirek; Zhu, X. Ronald; Brown, W. Douglas; Rand, Scott D.; Michel, Michelle A.; Campbell, Bruce H.; Wong, Stuart; Li, X. Allen; Wilson, J. Frank

    2006-01-01

    Purpose: The purpose of this study is to evaluate the impact of 18 F-fluorodeoxyglucose positron emission tomography (Fag-PET) fused with planning computed tomography (CT) on tumor localization, which guided intensity-modulated radiotherapy (Imr) of patients with head-and-neck carcinoma. Methods and Materials: From October 2002 through April 2005, we performed Fag-PET/CT guided Imr for 28 patients with head-and-neck carcinoma. Patients were immobilized with face masks that were attached with five fiducial markers. Fag-PET and planning CT scans were performed on the same flattop table in one session and were then fused. Target volumes and critical organs were contoured, and Imr plans were generated based on the fused images. Results: All 28 patients had abnormal increased uptake in Fag-PET/CT scans. PET/CT resulted in CT-based staging changes in 16 of 28 (57%) patients. PET/CT fusions were successfully performed and were found to be accurate with the use of the two commercial planning systems. Volume analysis revealed that the PET/CT-based gross target volumes (GTVs) were significantly different from those contoured from the CT scans alone in 14 of 16 patients. In addition, 16 of 28 patients who were followed for more than 6 months did not have any evidence of locoregional recurrence in the median time of 17 months. Conclusion: Fused images were found to be useful to delineate GTV required in IMRT planning. PET/CT should be considered for both initial staging and treatment planning in patients with head-and-neck carcinoma

  6. Diagnosis of gynecologic pelvic masses by CT scans

    International Nuclear Information System (INIS)

    Ito, Hisao; Kubo, Atsushi; Takagi, Yaeko; Kinoshita, Fumio; Maekawa, Akira.

    1981-01-01

    Two hundred eighty four patients with gynecologic pelvic masses were evaluated with CT scans. Of the patients, 196 had subsequent surgical determination of abnormalities and pathological proof of diagnosis was obtained. Only these 196 patients were included in this study. The CT scans could provide correct diagnosis in 113 of 114 (99%) patients with benign uterine tumor and in all (100%) patients with either serous cystadenoma or dermoid cyst. However, evaluation of mucinous cystadenoma (44%) and endometriosis cyst (37%) by CT scan has some limitations. It was difficult to differentiate mucinous cystadenoma from ovarian carcinoma, because both lesions had partial multiloculation and solid-like areas in the cyst. The CT findings of endometriosis cyst had similarity with serous cystadenoma, and 5 of 8 patients with this disease were diagnosed as serous cystadenoma. Ovarian fibroma and endometrial cancer were also not determined by CT scans. CT identified 87% of patients with ovarian cancer, while false positive rate of this disease was 38% (8/21). In 6 of 13 patients with both of leiomyoma and ovarian cyst, CT was able to demonstrate ovarian lesions that were overlooked by bimanual examinations. The role of CT scanning in our clinical practice is discussed. (author)

  7. CT scan findings in focal epilepsy

    International Nuclear Information System (INIS)

    Kobayashi, Eiki; Mihara, Tadahiro; Yamamoto, Kunimitsu; Yamashita, Kenji; Asakura, Tetsuhiko

    1980-01-01

    In 80 cases of focal epilepsy, excluding such cases as late onset after the age of 30 and traumatic or expansive lesions, the epileptogenic foci have been studied by comparing the CT findings with the seizure types and the EEG findings. The results were as follows: (1) Abnormal CT findings were observed in 36% of the patients. (2) These findings were classified into 4 large groups: localized cerebral atrophy, localized low density, localized high density with contrast enhancement and diffuse cerebral atrophy. (3) The incidence of CT abnormality was higher in the cases with continuous and localized EEG abnormality than in the cases with other types of EEG abnormality. In 48% of the cases, the location of the abnormal CT findings coincided with their EEG foci. (4) In the cases of temporal lobe epilepsy without abnormal CT images, the print-out data compared with the bilateral promised temporal regions, before and after contrast enhancement. The EMI-No. of the medial temporal focus increased more than that of the contralateral side in 3 cases out of 4 after contrast-media injection. (5) Moreover, for the purpose of comparing the CT findings on general seizures with those in focal seizures, we have studied 80 cases of general seizures. In the cases of the general seizures, abnormal CT findings were observed in only 16%. These abnormal findings were diffuse in 5 cases, localized in 6 cases, and combined in 3 cases. (author)

  8. Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2014-06-01

    Full Text Available Background and aims. Cone-beam computed tomography (CBCT is an imaging system which has many advantages over computed tomography (CT. In CT scan, Hounsfield Unit (HU is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value. The aim of the present study was to investigate the relationship between gray scale in CBCT and Hounsfield Unit (HU in CT scan. Materials and methods. In this descriptive study, the head of a sheep was scanned with 3 CBCT and one medical CT scanner. Gray scales and HUs were detected on images. Reconstructed data were analyzed to investigate relationship between CBCT gray scales and HUs. Results. A strong correlation between gray scales of CBCT and HUs of CT scan was determined. Conclusion. Considering the fact that gray scale in CBCT is the criteria in measurement of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  9. Photon CT scanning of advanced ceramic materials

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Ellingson, W.A.

    1987-02-01

    Advanced ceramic materials are being developed for high temperature applications in advanced heat engines and high temperature heat recovery systems. Small size flaws (10 - 200 μm) and small nonuniformities in density distributions (0.1 -2%) present as long-range density gradients, are critical in most ceramics and their detection is of crucial importance. Computed tomographic (CT) imaging provides a means of obtaining a precise two-dimensional density map of a cross section through an object from which accurate information about small flaws and small density gradients can be obtained. With the use of high energy photon sources high contrast CT images can be obtained for both low and high density ceramics. In the present paper we illustrate the applicability of the photon CT technique to the examination of advanced ceramics. CT images of sintered alumina tiles are presented from which data on high-density inclusions, cracks and density gradients have been extracted

  10. CT scan findings in cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Udaka, Fukashi; Okuda, Bungo; Okada, Masako; Okae, Shunji; Kameyama, Masakuni

    1982-01-01

    Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author)

  11. Head trauma and CT with special reference to diagnosis of complications of head trauma

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitose

    1979-01-01

    Cases in which CT was useful for the diagnosis of complications of head trauma were reported. First, complications of head trauma were given an outline, and then, cases of protrusion of the brain, traumatic pneumocephalus, and cerebro-vascular disorders caused by head trauma were mentioned. (Tsunoda, M.)

  12. Cushing's syndrome with an apparently normal CT scan

    International Nuclear Information System (INIS)

    Vlahos, L.; Strigaris, K.; Aliferopoulos, D.; Pontifex, G.

    1981-01-01

    A case of Cushing's syndrome is described in which the CT scan was considered as normal. The diagnosis was established with selective venography and blood sampling and was verified surgically. (orig.)

  13. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  14. Diagnostic efficacy and pitfalls of a 64-raw multislice computed tomography scan for mild head injuries in children

    International Nuclear Information System (INIS)

    Matsumoto, Yoshihisa; Nawashiro, Hiroshi; Uozumi, Youichi

    2010-01-01

    The aim of this study is to analyze the usefulness of 64-raw multislice computed tomography (CT) scans and bone images of three-dimensional CT (3D-CT) scans for evaluation of mild head injuries in children. Thirteen children (9 boys and 4 girls, less than or equal to 15 years old) with mild head injury were included in the study. Head CT scans obtained within 24 hours after injury. All children had no episodes of loss of consciousness, amnesia, epilepsy, vomiting, and no neurological abnormality on arrival at hospital. We detected 9 positive findings on CT scans, which looked like fracture lines at the frontal bone in 7 cases. The bone images of CT axial views revealed a true fracture in one case in which a skull X-ray could not demonstrate a fracture line, but, other positive findings turned out to be a diploic vein surrounded by a thin bone cortex. All false positive findings were detected in the patients under the age of 6. By the 3D-reconstructive CT scan, it is easier to detect not only the intracranial lesions but also the cranial fracture. But, the diploic vein is apt to be misdiagnosed as the fracture line, especially in patients under the age of 6. (author)

  15. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  16. Comparative evaluation of coronal images of the middle ear visualized by CT scan and polytomography

    International Nuclear Information System (INIS)

    Sugiyama, Masao; Nakai, Yoshiaki; Cho, Kansei; Tanabe, Kyoji; Inoue, Yuichi; Onoyama, Yasuto

    1982-01-01

    We retrospectively analysed the coronal images of the middle ear obtained by multidirectional tomography (polytomography) and computed tomography (CT) in 40 patients. Although CT was capable of demonstrating water density in the middle ear more clearly than polytomography and of delineating a lesion extending even outside of the petrous bone, the diagnostic capability was not much different between the two tomographic techniques. On the other hand, coronal CT scan has a disadvantage in that it usually has to be performed during hyperextension of the neck or while patients are in an uncomfortable hanging head position. We think that CT scan should be utilized only in case with a lesion extending beyond the petrous bone and/or is not well visualized by polytomography. (author)

  17. Dual scan CT image recovery from truncated projections

    Science.gov (United States)

    Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat

    2017-12-01

    There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.

  18. CT study of pancreatic diseases with modified dynamic scanning

    International Nuclear Information System (INIS)

    Qian Minghui; Zhu Guangying

    1990-01-01

    Experience of 20 cases modified dynamic CT scanning is presented. With a slight increased X-ray tube burden, it is possible to investigate tumor blood supply and find small pancreatic insulinoma with this method. The capsular sign typical for chronic traumatic pancreatic hematoma on CT is presented

  19. Dynamic CT scan in cerebral infarction

    International Nuclear Information System (INIS)

    Kobayashi, Shigeki; Oka, Nobuo; Mitsuhashi, Hiromitsu

    1984-01-01

    Forty-two dynamic CT studies were performed on 27 patients with cerebral infarction (11 to 75 years of age), and perfusion patterns of low density areas on plain CT were evaluated. The initial studies were performed 1.5 hours to 60 days after acute onset. The following results were obtained. 1) The perfusion pattern in the low density area on plain CT varies among patients at any periods after onset, ranging from absent perfusion pattern to hyperfusion pattern. No consisitent perfusion pattern was obtained at any given time after onset. 2) Repeat dynamic CT revealed that the perfusion pattern in the low density area changed with time variously. 3) The perfusion pattern or change of perfusion pattern did not correlate with outcome of the patient. 4) At an acute stage, when no abnormal findings were obtained on plain CT, dynamic CT revealed abnormal perfusion pattern, enabling early diagnosis of cerebral infarction and estimation of blood perfusion in the infarcted area. In determining the treatment for the cerebral infarction at an acute stage, it is important to know the condition of the blood perfusion in the infarcted area. For the patients in whom recanalization has already taken place, mannitol or steroid might be effective, providing protection against severe brain edema and hemorrhagic infarction. On the other hand, if recanalization has not taken place, revascularization therapy might be worth trying within 6 hours since the onset. It has been said that ischemic brain damage may not be reversed by the revascularization after 6 hours. Dynamic CT is safe, less invasive, convenient and very useful for early diagnosis of the cerebral infarction and determination of the treatment at the acute stage. (J.P.N.)

  20. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  1. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  2. CT scan findings of fungal pneumonia

    International Nuclear Information System (INIS)

    Heckmann, M.; Uder, M.; Bautz, W.; Heinrich, M.

    2008-01-01

    The importance of fungal infection of the lung in immunocompromised patients has increased substantially during the last decades. Numerically the most patients are those with neutropenia, e.g. patients with malignancies or solid organ and stem cell transplantation, chemotherapy, corticosteroid use and HIV infection. Although fungal infections can occur in immunocompetent patients, their frequency in this population is rare. The clinical symptoms such as fever accompanied with non-productive cough are unspecific. In some patients progression to hypoxemia and dyspnea may occur rapidly. In spite of improved antifungal therapy morbidity and mortality of these infections are still high. Therefore an early and non-invasive diagnosis is very important. That is why CT and even better High-Resolution-CT (HR-CT) is a very important modality in examining immunocompromised patients with a probability of fungal infection. CT is everywhere available and, as a non-invasive method, able to give the relevant diagnose efficiently. This paper should give an overview about the radiologic findings and possible differential diagnosis of diverse pulmonary fungal infections in CT. Pneumonias caused by Aspergillus, Cryptococcus, Candida, Histoplasma, Mucor and Geotrichum capitatum are illustrated. (orig.)

  3. Study on the brain CT scan of SLE patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S; Narita, M; Katoh, K; Matsunaga, K; Ishigatsubo, Y [Yokohama City Univ. (Japan). Faculty of Medicine

    1982-03-01

    Cranial CT scanning revealed abnormality in 12 of 25 patients with SLE (48%). Ventricular sulcal enlargement was found mostly in younger patients between 16 and 36 years, an average of 25 years. Abnormality in electroencephalogram, principally paroxysmal abnormality, was found in 8 of 13 cases (62%) of normal CT findings. Non-paroxysmal slow-wave abnormality was observed in 9 of 12 abnormal CT cases. Of 13 patients with CNS symptoms, 8 had abnormal CT findings, and 5 had only mental disorder with normal CT findings. In 12 patients without neuropsychiatric involvement, 4 (33%) had abnormal CT findings. The rate of abnormal CT findings was increased in the patients receiving a high dosage of a steroid agent. Five of 6 patients who showed ventricular sulcal enlargement had been given prednisolone in a dosage of 35 mg or more per day.

  4. Post-operative abdominal CT scanning in extrahepatic biliary atresia

    Energy Technology Data Exchange (ETDEWEB)

    Day, D L; Mulcahy, P F; Letourneau, J G; Dehner, L P

    1989-07-01

    A retrospective review of the abdominal CT scans of 26 children with extrahepatic biliary atresia was performed, and the results were correlated with available surgical and pathologic data. Associated congenital anomalies or acquired abnormalities were identified in these patients. Congenital anomalies included polysplenia, venous anomalies and bowel stenosis. Acquired abnormalities developed secondary to cirrhosis, portal hypertension, intrahepatic biliary duct dilatation, and hepatic ischemia. Despite frequent episodes of ascending cholangitis in these children, no hepatic abscesses were identified by CT or by pathologic examination. In conclusion, abdominal CT scanning of children with extrahepatic biliary atresia can define congenital and acquired abnormalities and provide important anatomic data for the surgeons before liver transplantation. (orig.).

  5. Emergency medicine summary code for reporting CT scan results: implementation and survey results.

    Science.gov (United States)

    Lam, Joanne; Coughlin, Ryan; Buhl, Luce; Herbst, Meghan; Herbst, Timothy; Martillotti, Jared; Coughlin, Bret

    2018-06-01

    The purpose of the study was to assess the emergency department (ED) providers' interest and satisfaction with ED CT result reporting before and after the implementation of a standardized summary code for all CT scan reporting. A summary code was provided at the end of all CTs ordered through the ED from August to October of 2016. A retrospective review was completed on all studies performed during this period. A pre- and post-survey was given to both ED and radiology providers. A total of 3980 CT scans excluding CTAs were ordered with 2240 CTs dedicated to the head and neck, 1685 CTs dedicated to the torso, and 55 CTs dedicated to the extremities. Approximately 74% CT scans were contrast enhanced. Of the 3980 ED CT examination ordered, 69% had a summary code assigned to it. Fifteen percent of the coded CTs had a critical or diagnostic positive result. The introduction of an ED CT summary code did not show a definitive improvement in communication. However, the ED providers are in consensus that radiology reports are crucial their patients' management. There is slightly increased satisfaction with the providers with less than 5 years of experience with the ED CT codes compared to more seasoned providers. The implementation of a user-friendly summary code may allow better analysis of results, practice improvement, and quality measurements in the future.

  6. Diagnostic value of the coronary CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1982-01-01

    Using high-resolution computed tomography, coronary scanning has been made to investigate the radiographical details of the middle and inner ear organs. Twenty patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, facial spasm, and suspected meningitis, were evaluated. In 26 of 40 ears in this series, the coronary scans sharply outlined almost all of the bony structures, and showed also the eardrum as a clearly defined soft tissue, but no abnormal radiographical findings were recognized. In the remaining ears with chronic otitis media, the scans were valuable in demonstration of mucosal thickening, granulation tissue, and destruction of the auditory ossicles. (author)

  7. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction

    International Nuclear Information System (INIS)

    Raissaki, Maria; Perisinakis, Kostas; Damilakis, John; Gourtsoyiannis, Nicholas

    2010-01-01

    CT scans of the brain, sinuses and petrous bones performed as the initial imaging test for a variety of indications have the potential to expose the eye-lens, considered among the most radiosensitive human tissues, to a radiation dose. There are several studies in adults discussing the reduction of orbital dose resulting from the use of commercially available bismuth-impregnated latex shields during CT examinations of the head. To evaluate bismuth shielding-induced artefacts and to provide suggestions for optimal eye-lens shielding in paediatric head CT. A bismuth shield was placed over the eyelids of 60 consecutive children undergoing head CT. Images were assessed for the presence and severity of artefacts with regard to eye-shield distance and shield wrinkling. An anthropomorphic paediatric phantom and thermoluminescence dosimeters (TLDs) were used to study the effect of eye lens-to-shield distance on shielding efficiency. Shields were tolerated by 56/60 children. Artefacts were absent in 45% of scans. Artefacts on orbits, not affecting and affecting orbit evaluation were noted in 39% and 14% of scans, respectively. Diagnostically insignificant artefacts on intracranial structures were noted in 1 case (2%) with shield misplacement. Mean eye-lens-to-shield distance was 8.8 mm in scans without artefacts, and 4.3 mm and 2.2 mm in scans with unimportant and diagnostically important artefacts, respectively. Artefacts occurred in 8 out of 9 cases with shield wrinkling. Dose reduction remained unchanged for different shield-to-eye distances. Bismuth shielding-related artefacts occurring in paediatric head CT are frequent, superficial and diagnostically insignificant when brain pathology is assessed. Shields should be placed 1 cm above the eyes when orbital pathology is addressed. Shield wrinkling should be avoided. (orig.)

  8. Classication Methods for CT-Scanned Carcass Midsections

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    Computed tomography (CT) has successfully been applied in medical environments for decades. In recent years CT has also made its entry to the industrial environments, including the slaughterhouses. In this paper we investigate classication methods for an online CT system, in order to assist...... in the segmentation of the outer fat layer in the mid- section of CT-scanned pig carcasses. Prior information about the carcass composition can potentially be applied for a fully automated solution, in order to optimize the slaughter line. The methods comprise Markov Random Field and contextual Bayesian classication...

  9. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  10. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  11. Prognosis of head injury. In relation to age, CT findings and the GCS on admission

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Satoshi; Kamei, Ichiro; Ooiwa, Yoshitsugu; Hyotani, Genhachi; Yabumoto, Michio; Kuriyama, Tsuyoshi [Japanese Red Cross Society, Wakayama (Japan). Wakayama Medical Center; Kakishita, Koji; Inui, Yoshiro

    1996-02-01

    We have carried out a retrospective study of head injury patients to determine the factors that predict their outcomes. The subjects consisted of 74 head injury patients (Glasgow Coma Scale: 3-12) treated at our hospital from January, 1989 to March, 1994. Age, CT findings and the GCS on admission were investigated as outcome-predicting factors. CT findings were classified according to the TCDB (Traumatic Coma Data Bank) and the outcomes were evaluated using the Glasgow Outcome Scale 3 months after the head injury. In our study, the factors indicated favorable outcomes were as follows; age younger than 50 years old, GCS higher than 6, appearance of the basal cisterns on CT scan, existence of removable acute epidural hematoma. In contrast, the factors that indicated unfavorable outcomes were as follows; disappearance of the basal cisterns on CT scan, existence of apparent acute subdural hematoma and/or intracranial hematoma associated with cerebral contusion. Based on these findings, we can more accurately estimate the prognosis of head injury. (author)

  12. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  13. An economic evaluation of introducing a skills mix approach to CT head reporting in clinical practice

    International Nuclear Information System (INIS)

    Lockwood, P.

    2016-01-01

    Background: Computed Tomography (CT) head examinations are a common diagnostic examination in National Health Service (NHS) acute hospital trusts. Current NHS England and Royal College of Radiologist (RCR) reports estimate the year on year increase of examinations to be 10%, with the designated workforce of radiologists disproportionate to the increase in demand of imaging reporting. Objective: To determine an economic evaluation of cost, risk and feasibility of introducing skills mix CT head reporting by radiographers. Design: Applying a PICO framework study to evaluate the patient workflow demand from retrospective audit data of CT head examination attendance (n = 7266) at an acute NHS district general hospital (DGH) to model an example workflow demand over 12 months. Reviewing potential outcome risk data (diagnostic thresholds), and feasibility (workforce capacity) of both interventions. The economic evaluation calculated hourly unit costs for comparison estimation of consultant radiologists and reporting radiographers using Netten et al.'s Ready Reckoner. Report unit costs were calculated utilising the Gishen's Ready Reckoner to estimate the uninterrupted time of reporting a non-complex CT report using RCR, Centre for Workforce Intelligence (CfWI) and Department of Health (DoH) estimates for both interventions. Conclusions: The economic evaluation of introducing a skills mix reporting service model to the benefit of service delivery with the NHS has shown a potential £299,359–£124,514 per annum cost saving using a generic acute DGH workload model. Research into recorded discrepancy/error audit data for potential detrimental risk to patient outcomes identified a paucity of evidence, and recommends further research is needed. - Highlights: • There was 5.2 million CT scans from April 2013 to March 2014 in the UK. • In 2015 the RCR estimated there were up to 3693 unreported CT scans. • Comparison of workforce, reference standards, unit costs

  14. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  15. CT-scanning of ancient Greenlandic Inuit temporal bones

    International Nuclear Information System (INIS)

    Homoe, P.; Videbaek, H.

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.)

  16. CT-scanning of ancient Greenlandic Inuit temporal bones

    Energy Technology Data Exchange (ETDEWEB)

    Homoe, P [Copenhagen Univ. (Denmark). Lab. of Biological Anthropology and Dept. of Otolaryngology, Head and Neck Surgery; Lynnerup, N [Copenhagen Univ., Lab. of Biological Anthropology and Univ. Inst. of Ferensic Medicine, Copenhagen (Denmark); Videbaek, H [Hvidovre Univ. Hospital, Copenhagen (Denmark). Dept. of Radiology

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.).

  17. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  18. Value of CT scan in synovial diseases

    International Nuclear Information System (INIS)

    Tamisier, J.N.; Regent, D.; Thomas, P.; Pere, P.; Gaucher, A.; Capesius, P.

    1986-01-01

    The authors have developed a technique of CT arthroscan which, by the use of a gas or opaque contrast medium, is able to demonstrate the synovial structures of the knee, the shoulder and the hip. Among the essential indications, they include the demonstration of neoplasia of the synovium and the evaluation of the pannus in rheumatoid arthritis. Their secondary indications include the demonstration of fluid effusions in the hip, the precise evaluation of hyperostotic lesions in the same joint, the detection of ossification phenomena in the capsule of the inter-apophyseal joints in ankylosing spondylitis and, in some cases, following negative or doubtful arthrography for the detection of synovial plica. They also recall the usefulness or the arthroscan in the diagnosis of lesions of the labrum glenoidale [fr

  19. Value of CT scan in synovial diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tamisier, J.N.; Regent, D.; Thomas, P.; Pere, P.; Gaucher, A.; Capesius, P.

    1986-02-01

    The authors have developed a technique of CT arthroscan which, by the use of a gas or opaque contrast medium, is able to demonstrate the synovial structures of the knee, the shoulder and the hip. Among the essential indications, they include the demonstration of neoplasia of the synovium and the evaluation of the pannus in rheumatoid arthritis. Their secondary indications include the demonstration of fluid effusions in the hip, the precise evaluation of hyperostotic lesions in the same joint, the detection of ossification phenomena in the capsule of the inter-apophyseal joints in ankylosing spondylitis and, in some cases, following negative or doubtful arthrography for the detection of synovial plica. They also recall the usefulness or the arthroscan in the diagnosis of lesions of the labrum glenoidale.

  20. Diagnosis of pituitary adenoma by dynamic CT scanning

    International Nuclear Information System (INIS)

    Tanabe, Sumiyoshi; Uede, Teiji; Daibo, Masahiko; Niwa, Jun; Hashi, Kazuo

    1988-01-01

    The advantage of high resolution CT in the diagnosis of pituitary microadenomas has been established, but the diagnosis becomes more difficult when the pituitary microadenoma is less than 5 mm in diameter. We have studied the usefulness of dynamic CT scans particularly for diagnosis of small microadenomas. The dynamic CT scans were performed for 61 normal pituitary glands and 68 pituitary adenomas (36 microadenomas, 32 macroadenomas) with a GECT/T 9800 scanner. Coronal sections of 1.5 mm thickness were taken at the plane just in front of the pituitary stalk of the pituitary gland. Following a bolus intra-venous injection of 40 - 60 ml of contrast media using an automatic injector, ten consecutive CT scans of 2 seconds scan time were obtained, beginning 2 seconds from the start of intravenous injection. The first seven scans were taken with an interval of 2.3 seconds, and the last three scans with an interval of 10 seconds. Then, time-density curves were obtained at the ROI which were set on the anterior pituitary gland, the vascular bed of the pituitary gland, the pituitary stalk and the area of the pituitary adenoma respectively. In a normal pituitary gland, the density increases gradually and makes an S shaped curve, then attains the maximum density value (92.3 CT number) approximately 60 seconds after the administration of contrast media. The pituitary vascular bed is located in midline on the upper surface of the pituitary gland, and shows a symmetrical square, triangular or rhomboid shape. In case of pituitary adenoma, the time-density curve makes a plateau curve and attains the maximum density value (60.1 CT number) approximately 60 seconds after the administration of contrast media. In microadenoma, the pituitary vascular bed is either deformed or compressed, showing an asymmetrical shape. (author)

  1. MRI of patients with cerebral palsy and normal CT scan

    International Nuclear Information System (INIS)

    Bogaert, P. van; Szliwowski, H.B.

    1992-01-01

    Three children with clinical evidence of cerebral palsy (CP) and normal cerebral computed tomography (CT) scans were evaluated by magnetic resonance imaging (MRI) to identify CT-undetectable white matter lesions in the watershed zones of arterial territories. The two patients with spastic diplegia showed bilateral lesions either in the subcortical regions or in the occipital periventricular regions. The patient with congenital hemiplegia exhibited unilateral lesions in the periventricular region. We conclude that MRI is more informative than CT for the evaluation of patients with CP. (orig.)

  2. MRI of patients with cerebral palsy and normal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Bogaert, P. van; Szliwowski, H.B. (Hopital Erasme, Brussels (Belgium). Dept. of Neurology); Baleriaux, D.; Christophe, C. (Hopital Erasme, Brussels (Belgium). Dept. of Radiology (Neuroradiology))

    1992-02-01

    Three children with clinical evidence of cerebral palsy (CP) and normal cerebral computed tomography (CT) scans were evaluated by magnetic resonance imaging (MRI) to identify CT-undetectable white matter lesions in the watershed zones of arterial territories. The two patients with spastic diplegia showed bilateral lesions either in the subcortical regions or in the occipital periventricular regions. The patient with congenital hemiplegia exhibited unilateral lesions in the periventricular region. We conclude that MRI is more informative than CT for the evaluation of patients with CP. (orig.).

  3. Analysis of cranial CT-scan findings in cerebral palsy

    International Nuclear Information System (INIS)

    Wada, Fumio; Andoh, Tadashi; Une, Koji; Takamatsu, Tsurukichi

    1981-01-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed. (author)

  4. Analysis of cranial CT-scan findings in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, F.; Andoh, T.; Une, K.; Takamatsu, T. (Kitakyushu Municipal Sogo-Ryoiku Center (Japan))

    1981-06-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed.

  5. The pictures of CT scan of gold pneumonitis

    International Nuclear Information System (INIS)

    Taguchi, Yoshio; Iwata, Takekuni; Kuroda, Yasumasa; Sadato, Norihiro; Tanemoto, Kiichiro; Adachi, Kazuhiko.

    1987-01-01

    We experienced two cases of gold pneumonitis and their interesting findings of CT scan. After the cessation of gold salt, both cases were treated with the corticosteroid, resulting in the disappearance of pulmonary manifestations and clearing of shadows on chest roentgenograms. The findings of CT scan on both cases were very interesting. They were the high density shadows along the bronchovascular bundles, the fluffy figures surroundings these shadows and band like shadows reached to the thoracic wall. We considered that each shadows were pathologically compatible with severe exudative changes of interstitial pneumonitis, shrinkage surroundings them and thickness of interlobular septum. (author)

  6. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    Science.gov (United States)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion

  7. CT scan imaging in cervical infections

    International Nuclear Information System (INIS)

    Marsot-Dupuch, K.; Janklewicz, Ph.; Chabolle, F.

    1988-01-01

    Infections of face and neck represent serious and potentially life threatening conditions that are sometimes difficult to differentiate from neoplasic tumours, especially in subacute clinical forms. Conventional radiographic techniques offer interest for cervical masses, except Ultra-Sonographic examen, in sites regarding vascular axes, but carries little value for evaluating their spread the into different cervical spaces. On the other hand, C.T. is valuable to precise the location and the extent and to determine its inflammatory nature by studying the fats and the aponeurosis around it. It helps in the analysis of associated adjacent signs: soft tissue swelling, extensive obliteration of adjacent fats, swelling of cervical aponeurosis, thickening of adjacent muscles. These findings are documented by the study of fourteen patients, admitted in St-Antopine hospital. All abcesses, except one, were easy to diagnose because of their low central attenuation. False negative cases are possible and noted by other authors. So, in absence of response to appropriate therapy, surgery is necessary to eliminate a misdiagnosed abcess. Furthermore, it's sometimes possible to suspect an etiology (foreign body, tuberculosis) [fr

  8. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  9. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  10. The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

    Science.gov (United States)

    Vorona, G A; Zuccoli, G; Sutcavage, T; Clayton, B L; Ceschin, R C; Panigrahy, A

    2013-01-01

    Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.

  11. Doses from pediatric CT examinations in Norway: are pediatric scan protocols developed and in daily use?

    International Nuclear Information System (INIS)

    Friberg, Eva G.

    2008-01-01

    Doses to pediatric patients from CT examinations are known to be unnecessarily high if scan protocols developed for adult patients are adopted. This overexposure is most often not recognized by the operating radiographer, due to the digital behavior of the imaging system. Use of optimized size-specific pediatric scan protocols is therefore essential to keep the doses at an appropriate level. The aim of this study was to investigate the doses to pediatric patients from CT examinations and to evaluate the level of optimization of the scan protocols. Patient data, applied scan parameters together with the dose parameters volume computed tomography dose index (CTD vol ) and dose length product (DLP) for examinations of the head, chest and abdomen were collected by means of a questionnaire from five university hospitals. The effective dose was estimated from the total DLP by use of region-specific conversion coefficients (E DLP ). Totally 136, 108 and 82 questionnaires were received for examinations of the head, chest and abdomen, respectively. Large variations in patient doses between the hospitals were observed, addressing the need for optimization of the scan protocols in general. Most of the hospitals applied successive lower mAs with decreasing patient age for all scan areas, while the use of lower tube voltage for small patients and a higher tube voltage for large patients were more rarely. This indicates the presence, to a certain level, of size specific scan protocols at some Norwegian hospitals. Focus on developing size-specific scan protocols for pediatric patients are important to reduce the doses and risks associated with pediatric CT examinations. (author)

  12. Radiation dose reduction with dictionary learning based processing for head CT

    International Nuclear Information System (INIS)

    Chen, Yang; Shi, Luyao; Hu, Yining; Luo, Limin; Yang, Jiang; Yin, Xindao; Coatrieux, Jean-Louis

    2014-01-01

    In CT, ionizing radiation exposure from the scan has attracted much concern from patients and doctors. This work is aimed at improving head CT images from low-dose scans by using a fast Dictionary learning (DL) based post-processing. Both Low-dose CT (LDCT) and Standard-dose CT (SDCT) nonenhanced head images were acquired in head examination from a multi-detector row Siemens Somatom Sensation 16 CT scanner. One hundred patients were involved in the experiments. Two groups of LDCT images were acquired with 50 % (LDCT50 %) and 25 % (LDCT25 %) tube current setting in SDCT. To give quantitative evaluation, Signal to noise ratio (SNR) and Contrast to noise ratio (CNR) were computed from the Hounsfield unit (HU) measurements of GM, WM and CSF tissues. A blinded qualitative analysis was also performed to assess the processed LDCT datasets. Fifty and seventy five percent dose reductions are obtained for the two LDCT groups (LDCT50 %, 1.15 ± 0.1 mSv; LDCT25 %, 0.58 ± 0.1 mSv; SDCT, 2.32 ± 0.1 mSv; P < 0.001). Significant SNR increase over the original LDCT images is observed in the processed LDCT images for all the GM, WM and CSF tissues. Significant GM–WM CNR enhancement is noted in the DL processed LDCT images. Higher SNR and CNR than the reference SDCT images can even be achieved in the processed LDCT50 % and LDCT25 % images. Blinded qualitative review validates the perceptual improvements brought by the proposed approach. Compared to the original LDCT images, the application of DL processing in head CT is associated with a significant improvement of image quality.

  13. Comparison of intracranial computed tomographic (CT) findings in pediatric abusive and accidental head trauma

    International Nuclear Information System (INIS)

    Hymel, K.P.; Rumack, C.M.; Hay, T.C.; Strain, J.D.; Jenny, C.

    1997-01-01

    Background. Child abuse specialists rely heavily on diagnostic neuroimaging. Objectives. Study objectives were: (1) to compare the frequencies of six specific intracranial CT abnormalities in accidental and non-accidental pediatric head trauma, and (2) to assess interobserver agreement regarding these CT findings. Materials and methods. Three pediatric radiologists blindly and independently reviewed cranial CT scans of pediatric patients who sustained closed head trauma between 1991 and 1994. All patients were less than 4 years of age. Study cases included thirty-nine (50 %) with non-accidental head trauma and thirty-nine (50 %) with accidental head trauma. Each scan was evaluated for the presence or absence of the following six intracranial findings: (1) interhemispheric falx hemorrhage, (2) subdural hemorrhage, (3) large (non-acute) extra-axial fluid, (4) basal ganglia edema, (5) posterior fossa hemorrhage, and (6) frontal-parietal shearing tear(s). Interobserver agreement was calculated as the percentage of total cases in which all reviewers agreed a specific CT finding was present or absent. Diagnosis required independent agreement by all three pediatric radiologists. The frequencies of these six intracranial CT abnormalities were compared between the two study groups by Chi-square analysis and Fisher's exact test. Results. Interobserver agreement between radiologists was greater than 80 % for all lesions evaluated, with the exception of frontal-parietal shearing tear(s). Interhemispheric falx hemorrhage, subdural hemorrhage, large (non-acute) extra-axial fluid, and basal ganglia edema were discovered significantly more frequently in non-accidental trauma (P ≤.05). Conclusion. Although not specific for child abuse, discovery of these intracranial CT abnormalities in young patients should prompt careful evaluation of family and injury circumstances for indicators of non-accidental trauma. (orig.). With 6 figs., 2 tabs

  14. Adenocarcinoma of the pancreatic head: preoperative helical CT. Criteria of resectability

    International Nuclear Information System (INIS)

    Kozima, Shigeru; Szelagowski, Carlos; Tisserand, Guy L.; Ocampo, Carlos; Zandalazini, Hugo; Silva, Walter; Oria, Alejandro; Vidovic, Gustavo; Varas, Pablo

    2001-01-01

    Objective: The purpose of this study is to determine the accuracy of biphasic helical CT scanning in predicting resectability of adenocarcinoma of the head of the pancreas by staying tumor involvement of the portal and superior mesenteric veins. Material and methods: 46 patients with proven adenocarcinoma of the head of the pancreas who underwent curative or palliative surgery were studied with preoperative biphasic helical CT scanning. Tumor involvement of the portal and mesenteric veins was graduated on a 1-3 scale based on circumferential contiguity of the tumor vessel. Grade 1: without contact; grade 2: tumor involvement of less than 50% of the vessel; grade 3: tumor involvement of more than 50%. Results: The total number of vessels evaluated was 92. In our series the preoperative biphasic helical CT was accurate in 77% for resectability and unresectability. Conclusion: Our experience of staging in 3 grades with biphasic helical CT, vessel involvement the portal and superior mesenteric veins of adenocarcinoma of the head of the pancreas is highly specific for unresectable tumor in patients who were graded 2 and 3. (author)

  15. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  16. Intrathoracic kidney. Diagnostic value of CT scan imaging

    International Nuclear Information System (INIS)

    Baillet, A.M.; Escure, M.N.

    1988-01-01

    Two cases are reported of an ectopic right kidney that was partially intrathoracic in position. Diagnosis was simple from CT scan imaging appearances, the examination being performed to investigate an intrathoracic mass. Images showed a tissular mass within a fatty zone in sections without contrast and the typical appearance of the kidney on sections with contrast [fr

  17. Serial CT scans and Menkes' kinky hair disease

    International Nuclear Information System (INIS)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-01-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 μ g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died. (author)

  18. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  19. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal...

  20. Technological features and clinical feasibility of megavoltage CT scanning

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Akanuma, Atsuo; Sakata, Kouichi; Karasawa, Katsuyuki; Terahara, Atsurou; Onogi, Yuzou; Hasezawa, Kenji; Sasaki, Yasuhito

    1992-01-01

    Megavoltage CT scanning using 4-MV and 6-MV radiotherapy beams has been developed and applied to verify errors in patient positioning. A detector system composed of 120 pairs of cadmium tungstate scintillators with photodiodes is mounted to the treatment unit at a distance of 160 cm from the beam source. Image reconstruction is performed with a standard filtered back-projection algorithm. Scanning time and reconstruction time for a slice is approximately 35 s and 60 s respectively. Although spatial resolution is as large as 4 mm, it has sufficient image quality to be applied for treatment planning and verification. The delivered dose with 4 MV and 6 MV is about 1.4 cGy and 2.8 cGy respectively. When a megavoltage CT image is taken in treatment position, the positioning errors are easily detected by comparing it with diagnostic CT sections for treatment planning. Several clinical examples are presented. (orig.)

  1. CT perfusion scanning of the brain in stroke and beyond

    International Nuclear Information System (INIS)

    Riedel, Christian

    2011-01-01

    CT perfusion scanning (CTP) allows for quantitative analysis of cerebral blood flow (CBF) and cerebral blood volume (CBV). Until recently, it was only possible to study brain perfusion parameters in a small stack of CT-slices close to the skull base. With the introduction of multidetector CT scanners with 64 and more detector rows it has become possible to assess perfusion of the entire brain. An optimal choice of scanning parameters like the new 'shuttle'-technique combined with a well adapted regimen for contrast administration is required to guarantee reliable perfusion measurements while still keeping the X-ray dose absorbed by the patient at a minimum. With these techniques, CTP is not only an important modality in the work-up of patients suffering from acute ischemic stroke but can also be valuable in other emergency situations such as in prolonged epileptic seizures or to monitor patients with subacute subarachnoid hemorrhage. (orig.)

  2. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Masanori [Keio Univ., Tokyo (Japan). School of Medicine

    1997-11-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  3. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ishibashi, Masanori

    1997-01-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  4. CT Scanning in Identification of Sheep Cystic Echinococcosis.

    Science.gov (United States)

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei; Bao, Yongxing; Li, Haitao

    2017-01-01

    We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung ( R = 0.770, P < 0.001). CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure.

  5. Helical CT scan for emergent patients with cerebrovascular diseases

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio

    1995-01-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author)

  6. Helical CT scan for emergent patients with cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio [Fukushima Medical Coll. (Japan)

    1995-08-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author).

  7. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  8. A new method of CT scanning for the diagnosis of mandibular fractures

    International Nuclear Information System (INIS)

    Tsukagoshi, Taku; Satoh, Kaneshige; Onizuka, Takuya

    1990-01-01

    The condylar neck of the mandible is one of the most common fracture sites in the facial skeleton. Such a fracture is routinely diagnosed by A-P, lateral oblique, and Towne projection roentgenography or orthopantomography. Despite the combination of these films, fracture of the neck of the mandible is still difficult to diagnose definitely. Therefore, a new CT scanning method was developed for diagnosing fractures of the neck of the condylar mandible. The CT axis is projected along the length of the mandible, extending from the condyle to the symphysis. This projection visualizes both the condyle and the mandibular symphysis in the same plane. The patient is placed in a supine position with the head fully extended. The base line, a line extending from the midpoint of the glenoid fossa to the menton, is determined with a lateral facial cephalogram. CT scanning with a 5 mm window is performed in parallel with and 2 cm anterior to and 2 cm posterior to the base line. When CT scanning was performed in a healthy volunteer, the condition of the condyle and the condylar neck of the mandible was clearly shown, and the view extended from the condyle to the symphysis. For automobile accident patients in whom fracture of the neck of the mandible was associated with fracture of the symphysis, two fractures were found in the same plane. A newly developed CT scanning technique is useful in the diagnosis of fractures of the condylar neck of the mandible and in the identification of fractures at other mandibular sites. It also allows scanning of patients in a supine position, which may aid in managing patients with multiple traumas. (N.K.)

  9. Dose responses in a normoxic polymethacrylic acid gel dosimeter using optimal CT scanning parameters

    Energy Technology Data Exchange (ETDEWEB)

    Cho, K.H. [Department of Radiation Oncology, College of Medicine, Soonchunhyang University, Bucheon 420-767 (Korea, Republic of); Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of); Cho, S.J. [Department of Radiation Oncology, College of Medicine, Eulji University, Seongnam 461-713 (Korea, Republic of); Lee, S. [Department of Radiation Oncology, College of Medicine, Korea University, Seoul 130-701 (Korea, Republic of); Lee, S.H. [Cheil General Hospital and Women' s Healthcare Center, Kwandong University College of Medicine, Seoul 100-380 (Korea, Republic of); Min, C.K.; Kim, Y.H.; Moon, S.K.; Kim, E.S.; Chang, A.R. [Department of Radiation Oncology, College of Medicine, Soonchunhyang University, Bucheon 420-767 (Korea, Republic of); Kwon, S.I., E-mail: sikwon@kyonggi.ac.kr [Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of)

    2012-05-21

    The dosimetric characteristics of normoxic polymethacrylic acid gels are investigated using optimal CT scanning parameters and the possibility of their clinical application is also considered. The effects of CT scanning parameters (tube voltage, tube current, scan time, slick thickness, field of view, and reconstruction algorithm) are experimentally investigated to determine the optimal parameters for minimizing the amount of noise in images obtained using normoxic polymethacrylic acid gel. In addition, the dose sensitivity, dose response, accuracy, and reproducibility of the normoxic polymethacrylic acid gel are evaluated. CT images are obtained using a head phantom that is fabricated for clinical applications. In addition, IMRT treatment planning is performed using a Tomotherapy radiation treatment planning system. A program for analyzing the results is produced using Visual C. A comparison between the treatment planning and the CT images of irradiated gels is performed. The dose sensitivity is found to be 2.41{+-}0.04 HGy{sup -1}. The accuracies of dose evaluation at doses of 2 Gy and 4 Gy are 3.0% and 2.6%, respectively, and their reproducibilities are 2.0% and 2.1%, respectively. In the comparison of gel and Tomotherpay planning, the pass rate of the {gamma}-index, based on the reference values of a dose error of 3% and a DTA of 3 mm, is 93.7%.

  10. Dose responses in a normoxic polymethacrylic acid gel dosimeter using optimal CT scanning parameters

    Science.gov (United States)

    Cho, K. H.; Cho, S. J.; Lee, S.; Lee, S. H.; Min, C. K.; Kim, Y. H.; Moon, S. K.; Kim, E. S.; Chang, A. R.; Kwon, S. I.

    2012-05-01

    The dosimetric characteristics of normoxic polymethacrylic acid gels are investigated using optimal CT scanning parameters and the possibility of their clinical application is also considered. The effects of CT scanning parameters (tube voltage, tube current, scan time, slick thickness, field of view, and reconstruction algorithm) are experimentally investigated to determine the optimal parameters for minimizing the amount of noise in images obtained using normoxic polymethacrylic acid gel. In addition, the dose sensitivity, dose response, accuracy, and reproducibility of the normoxic polymethacrylic acid gel are evaluated. CT images are obtained using a head phantom that is fabricated for clinical applications. In addition, IMRT treatment planning is performed using a Tomotherapy radiation treatment planning system. A program for analyzing the results is produced using Visual C. A comparison between the treatment planning and the CT images of irradiated gels is performed. The dose sensitivity is found to be 2.41±0.04 HGy-1. The accuracies of dose evaluation at doses of 2 Gy and 4 Gy are 3.0% and 2.6%, respectively, and their reproducibilities are 2.0% and 2.1%, respectively. In the comparison of gel and Tomotherpay planning, the pass rate of the γ-index, based on the reference values of a dose error of 3% and a DTA of 3 mm, is 93.7%.

  11. Reducing Radiation Dose in Adult Head CT using Iterative Reconstruction - A Clinical Study in 177 Patients.

    Science.gov (United States)

    Kaul, D; Kahn, J; Huizing, L; Wiener, E; Grupp, U; Böning, G; Ghadjar, P; Renz, D M; Streitparth, F

    2016-02-01

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n = 71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n = 86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n = 74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n = 20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n = 20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up. ASIR may reduce radiation significantly while maintaining adequate image quality. cCT protocol with 20 % ASIR and 40 %ASIR/60 %FBP blending is adequate for everyday clinical use. cCT protocol with 30 % ASIR and 50 %ASIR/50 %FBP blending is adequate for follow-up imaging © Georg Thieme Verlag KG Stuttgart · New York.

  12. Intraobserver and Interobserver Variability in GTV Delineation on FDG-PET-CT Images of Head and Neck Cancers

    International Nuclear Information System (INIS)

    Breen, Stephen L.; Publicover, Julia; De Silva, Shiroma; Pond, Greg; Brock, Kristy; O'Sullivan, Brian; Cummings, Bernard; Dawson, Laura; Keller, Anne; Kim, John; Ringash, Jolie; Yu, Eugene; Hendler, Aaron; Waldron, John

    2007-01-01

    Purpose: To determine if the addition of fluorodeoxyglucose positron emission tomography (FDG-PET) data changes primary site gross tumor volumes (GTVs) in head and neck cancers. Methods and Materials: Computed tomography (CT), contrast-enhanced CT, and FDG-PET-CT scans were obtained in 10 patients with head and neck cancers. Eight experienced observers (6 head and neck oncologists and 2 neuro-radiologists) with access to clinical and radiologic reports outlined primary site GTVs on each modality. Three cases were recontoured twice to assess intraobserver variability. The magnitudes of the GTVs were compared. Intra- and interobserver variability was assessed by a two-way repeated measures analysis of variance. Inter- and intraobserver reliability were calculated. Results: There were no significant differences in the GTVs across the image modalities when compared as ensemble averages; the Wilcoxon matched-pairs signed-rank test showed that CT volumes were larger than PET-CT. Observers demonstrated the greatest consistency and were most interchangeable on contrast-enhanced CT; they performed less reliably on PET-CT. Conclusions: The addition of PET-CT to primary site GTV delineation of head and neck cancers does not change the volume of the GTV defined by this group of expert observers in this patient sample. An FDG-PET may demonstrate differences in neck node delineation and in other disease sites

  13. Reducing dose in head CT: A phantom study

    International Nuclear Information System (INIS)

    Perez Diaz, M.; Carvalho, A. E.; Andrade, M. E.; Khoury, H. J.

    2013-01-01

    Thirty two head CT scans were acquired employing an anthropomorphic phantom which contains small lesions in posterior fosse, using 2 scanners, one with 64 slices 'Siemens Sensation' and other with 6 slices P hilip Brilliance . Parameters as Tube current (I [mA]), Collimation (C [mm]), spectrum energy (kVp) and dynamic range were changed during studies, looking for the optimal acquisition/processing conditions which permit both, good lesion detectability and the lowest dose. Air kerma (mGy) was measured with a ionization chamber and the air kerma index (Ca,100 [mGy]) was calculated as dose index. Image quality was analyzed by 5 expert criteria using a 5 points-scale (1=poor, 2=fair, 3=good, 4=very good, 5=excellent) and also using 5 Figure of merit in the spatial and frequency domains: Contrast C(%), Contrast to Noise Ratio CNR, Signal to Noise Ratio SNR, Normalized Mean Square Error (NMSE) and the Spectral Distance (SD). Objective and subjective results were correlated. We observed that doses can be diminished until a 25% respect to the usual practice with both technologies, diminishing mainly the mAs, without affecting lesion detection. As a result, we propose an optimized protocol for each scanner as follow: The use of 250 mAs, 120 kVp and the collimation of 6 slices x 1.50 mm per rotation to detect the lesions in posterior fosse with good image quality for the Philips Brilliance 6 tested, while 150 mAs, 100 kVp and slice thickness of 3 mm were needed with the Siemens Sensation 64. (Author)

  14. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  15. CT and MR imaging of closed head trauma

    International Nuclear Information System (INIS)

    Park, Byung Moon; Kim, Wan Jin; Kim, Dae Ho; Lee, Hae Kyung; Chung, Moo Chan; Kwon, Kui Hyang; Kim, Ki Jeong

    1990-01-01

    The distribution and extent of traumatic lesions were evaluated with MR imaging in 40 patients with closed head injuries. The primary intraaxial lesions were classified into four main types, according to their topographical distribution within the brain ; cortical contusion (54%), diffuse axonal injury (35%), subcortical gray matter injury (4%), primary brain stem injury (7%). MR was found to be superior to CT and to be very useful in the detection of traumatic head lesions and T2WI were most useful for lesion detection. But T1WI proved to be also useful for detection of hemorrhage and anatomical localization

  16. Spontaneous spinal epidural hematoma diagnosed by CT scan

    International Nuclear Information System (INIS)

    Abumiya, Takeo; Isu, Toyohiko; Iwasaki, Yoshinobu; Akino, Minoru; Abe, Hiroshi

    1985-01-01

    A case of spinal epidural hematoma diagnosed by CT scan is reported. A 58-year-old man was admitted on June 18, 1984. He had had a sudden onset of severe low-back pain 7 days before admission and had developed paraparesis and numbness of the lower limbs 4 day before admission. Physical examination revealed weakness in the lower limbs, with the reflexes there decreased. The Babinski reflex and the Chaddock reflex were, however, present on both sides. Sensory disturbances were noted below L 2 . Urinary incontinence was present, too. Metrizamide myelography revealed an epidural mass which was located from the power part of T 11 to the upper part of L 2 . A CT scan revealed a biconvex, relatively high-density mass in the posterior spinal canal. On the day of admission, a laminectomy was performed from T 11 to L 1 , and the epidural hematoma was evacuated. The postoperative course was uneventful. Spinal epidural hematoma is uncommon. A CT scan can be used for an early diagnosis of this lesion. According to the review of the CT findings in 15 reported cases, including our case, CT reveals a smoothly marginated biconvex homogeneous density mass. The density of the hematoma decreases with the time. An acute type (within 3 days) is high-density, while a chronic type has a relatively high or isodensity. The acute type is easily differentiated from other epidural masses, such as a herniated disc, an epidural abscess, and an epidural tumor. On the other hand, the diagnosis of the chronic type is not always easy. (author)

  17. Brain atrophy in Huntington's disease: A CT-scan study

    International Nuclear Information System (INIS)

    Starkstein, S.E.; Folstein, S.E.; Brandt, J.; McDonnell, A.; Folstein, M.

    1989-01-01

    CT-scan measurements of cortical and subcortical atrophy were carried out in 34 patients with Huntington's disease (HD). While a significant correlation was observed between parameters of subcortical atrophy (bicaudate ratio, bifrontal ratio and third ventricular ratio) and duration of the disease, there was no significant correlation between these parameters and age. On the other hand, measurements of cortical atrophy (frontal fissure ratio and cortical sulci ratio) correlated significantly with age but not with duration of the disease. When a group of 24 HD patients were compared on CT-scan measurements with a group of 24 age-matched normal controls, significant differences were obtained for all the variables examined, but the bicaudate ratio showed the highest sensitivity and specificity. Even mildly affected patients, with duration of motor symptoms less than 3 years had higher bicaudate ratios than age-matched controls. (orig.)

  18. Progression of CT scan findings in Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hisaharu; Hirayama, Yoshito; Sakuragawa, Norio; Arima, Masataka (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan))

    1989-07-01

    Progression of the lesions revealed by CT scan was observed in five girls with Rett syndrome. The most distinct and common finding was progressive dilatation of Sylvian fissures, frontal extracerebral space, interhemispheric fissure, and sulci mainly in frontal lobe. It may indicate progressive lesion in the frontal and the temporal lobes. In addition, dilatation of the anterior horns of the lateral ventricles and the third ventricle was noted in some cases. Brainstem and cerebellum were small at any age with some morphological development as the patients became elder. Neither malformations nor abnormalities in density were found in any case. It is concluded that the main lesion of Rett syndrome on CT scan is progressive and localized in the frontal and the temporal lobes. (author).

  19. Evaluation in the use of bismuth shielding on cervical spine CT scan using a male phantom

    International Nuclear Information System (INIS)

    Aleme, C.; Mourao, A. P.; Lyra, M. A.

    2014-08-01

    The cervical spine is the region of the column that articulates the head and chest. The tests of computed tomography (CT) performed in this region have as main objectives to diagnose fractures, dislocations and tumors. In CT scans the cervical spine volume is limited by the foramen Magnum and the first thoracic vertebra. In this region is the thyroid that is directly irradiated by X-ray beam during cervical scan. Based on this information, it was studied the dose variation deposited in thyroid and in nearby organs, such as: lenses, spinal cord in the foramen Magnum region and breasts, with and without the use of bismuth protector. In this study was used a male anthropomorphic phantom and thermoluminescent s dosimeters (TLD-100) were required to register the individual doses in the organs of interest. CT scans were performed on a GE Bright Speed scanner of 32 channels. With the data obtained, it was found the organ dose variation. The largest recorded dose was in the thyroid. Comparing two scans it was possible to note that the use of the bismuth protector promoted a 26% reduction in the thyroid dose and an increase in the lens dose. (Author)

  20. Evaluation in the use of bismuth shielding on cervical spine CT scan using a male phantom

    Energy Technology Data Exchange (ETDEWEB)

    Aleme, C.; Mourao, A. P. [Centro Federal de Educacion Tecnologica de Minas Gerais, Biomedical Engineering Center, Belo Horizonte - MG (Brazil); Lyra, M. A., E-mail: carolinaaleme@gmail.com [Universidad Federal de Minas Gerais, Department of Nuclear Engineering, Av. Pdte. Antonio Carlos 6627, Pampulha, 31270-91 Belo Horizonte - MG (Brazil)

    2014-08-15

    The cervical spine is the region of the column that articulates the head and chest. The tests of computed tomography (CT) performed in this region have as main objectives to diagnose fractures, dislocations and tumors. In CT scans the cervical spine volume is limited by the foramen Magnum and the first thoracic vertebra. In this region is the thyroid that is directly irradiated by X-ray beam during cervical scan. Based on this information, it was studied the dose variation deposited in thyroid and in nearby organs, such as: lenses, spinal cord in the foramen Magnum region and breasts, with and without the use of bismuth protector. In this study was used a male anthropomorphic phantom and thermoluminescent s dosimeters (TLD-100) were required to register the individual doses in the organs of interest. CT scans were performed on a GE Bright Speed scanner of 32 channels. With the data obtained, it was found the organ dose variation. The largest recorded dose was in the thyroid. Comparing two scans it was possible to note that the use of the bismuth protector promoted a 26% reduction in the thyroid dose and an increase in the lens dose. (Author)

  1. Segmentation of organs at risk in CT volumes of head, thorax, abdomen, and pelvis

    Science.gov (United States)

    Han, Miaofei; Ma, Jinfeng; Li, Yan; Li, Meiling; Song, Yanli; Li, Qiang

    2015-03-01

    Accurate segmentation of organs at risk (OARs) is a key step in treatment planning system (TPS) of image guided radiation therapy. We are developing three classes of methods to segment 17 organs at risk throughout the whole body, including brain, brain stem, eyes, mandible, temporomandibular joints, parotid glands, spinal cord, lungs, trachea, heart, livers, kidneys, spleen, prostate, rectum, femoral heads, and skin. The three classes of segmentation methods include (1) threshold-based methods for organs of large contrast with adjacent structures such as lungs, trachea, and skin; (2) context-driven Generalized Hough Transform-based methods combined with graph cut algorithm for robust localization and segmentation of liver, kidneys and spleen; and (3) atlas and registration-based methods for segmentation of heart and all organs in CT volumes of head and pelvis. The segmentation accuracy for the seventeen organs was subjectively evaluated by two medical experts in three levels of score: 0, poor (unusable in clinical practice); 1, acceptable (minor revision needed); and 2, good (nearly no revision needed). A database was collected from Ruijin Hospital, Huashan Hospital, and Xuhui Central Hospital in Shanghai, China, including 127 head scans, 203 thoracic scans, 154 abdominal scans, and 73 pelvic scans. The percentages of "good" segmentation results were 97.6%, 92.9%, 81.1%, 87.4%, 85.0%, 78.7%, 94.1%, 91.1%, 81.3%, 86.7%, 82.5%, 86.4%, 79.9%, 72.6%, 68.5%, 93.2%, 96.9% for brain, brain stem, eyes, mandible, temporomandibular joints, parotid glands, spinal cord, lungs, trachea, heart, livers, kidneys, spleen, prostate, rectum, femoral heads, and skin, respectively. Various organs at risk can be reliably segmented from CT scans by use of the three classes of segmentation methods.

  2. Topographic diagnosis of parathyroid tumor by CT scan

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Harioka, Toshio; Morita, Rikuji

    1981-01-01

    In order to detect the hyperfunctioning parathyroid gland(s), CT scan over the neck was performed in patients with parathyroid disorders, including 10 primary hyperparathyroidism (6 bone type, 3 stone type and 1 chemical type), 8 chronic renal failure on hemodialysis with renal osteodystrophy and 2 multiple endocrine adenomatosis (MEA) type I. We used a whole-body scanner (CT/T, GE). The slice thickness was 5 mm. All patients were scanned from the sternal notch upward to the larynx, and were enhanced by the administration of 30% DIP Conray for 15 min. The results of the topographic diagnosis were compared with the surgical findings. Precise preoperative localization was accomplished in 9/10 adenomas in primary hyperparathyroidism, 27/32 hyperplasias in secondary hyperparathyroidism, and 2/4 hyperplasias in MEA type I. The smallest lesion weighed 0.2 g. It was shown that CT scan over the neck was a noninvasive and simple method to define the localization of hyperfunctionig parathyroid gland(s). (author)

  3. Efficacy of breast shielding during CT of the head

    International Nuclear Information System (INIS)

    Brnic, Z.; Hebrang, A.; Anic, P.

    2002-01-01

    The aims of this study were to investigate in vivo the levels of breast exposure to scatter radiation in head CT examination and the dependence of breast exposure upon body constitution. We tried to estimate the efficacy of external lead shielding as a mean of breast dose reduction. We wanted to estimate how much radiation reaches the organ from outside, in comparison to radiation load due to internal scatter

  4. Evaluation of radiation dose in pediatric head CT examination: a phantom study

    Science.gov (United States)

    Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, Ahmad Taufek Abdul

    2018-01-01

    The aim of this study was to evaluate the radiation dose in pediatric head Computed Tomography examination. It was reported that decreasing tube voltage in CT examination can reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The average dose was 2.60 mGy at CT imaging parameters of 80 kV and 10 - 30 mAs. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

  5. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    International Nuclear Information System (INIS)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J.

    2016-01-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  6. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    Energy Technology Data Exchange (ETDEWEB)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland)

    2016-10-15

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  7. MRI of head trauma. Serial changes and comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Osamu; Sato, Shuji; Suzuki, Takashi; Endo, Shunro; Takaku, Akira.

    1988-08-01

    Sequential changes in magnetic resonance imaging (MRI) were investigated in comparison with computed tomography (CT) in 31 cases of head trauma. Twenty-one of them were of acute head trauma; the first MRI study was performed within 48 hours after the accident. Forty-two intracranial lesions were observed in these cases on MRI. The other 10 cases were of chronic subdural hematoma, two cases of which had bilateral lesions. Fourteen lesions of acute head trauma and two lesions of chronic subdural hematoma were detected only by MRI. MRI was superior to CT for the detection of small contusions and thin extra-axial collections, especially those which were located near the bony structures. The abnormal lesions were visualized in MRI during a longer period than in CT. Because the signal intensity of a hematoma changed sequentially, the detection of brain edema was easier than that of a subarachnoid and parenchimal hemorrhage. Judging from this experience, it seems that careful attention should be taken in the diagnosis of hemorrhagic lesions. However, MRI was poor in tissue characterization because of the too-high tissue sensitivity. T/sub 2/-weight SE imaging was essentially sensitive and useful in the early stage.

  8. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  9. Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Alan J.; Vora, Nayana [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States); Suh, Steve [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Liu, An, E-mail: aliu@coh.org [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Schultheiss, Timothy E. [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Wong, Jeffrey Y.C. [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States)

    2015-04-01

    The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

  10. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  11. Quantitative measurement of ventricular dilatation on CT scan

    International Nuclear Information System (INIS)

    Okita, Naoshi; Mochizuki, Hiroshi; Takase, Sadao

    1985-01-01

    Cerebral atrophy might be judged from the ventricular dilatation with some indices, calculated from various ventricular width. But, there is no general agreement on what index is the most reliable. In this paper, we attempted to establish the index, easy to measure and most reliable. Our method is as follow. 1) We carried out the CT scan (EMI 1010) on 89 neurologically intact patients. Scans were parallel to orbito-meatal line (OML), and were 10 mm in thickness. On CT scan films, various width, area of anterior horns and area of bodies of lateral ventricles were measured. Measurement about the anterior horns of lateral ventricles were carried out on image the most clearly showed the foramen of Monro. And measurements about the bodies of lateral ventricles were on image, 20 mm above the image of anterior horn. Correlations of various width and areas were calculated. Then we proposed new indices with high correlations (over 0.9) with ventricular area; Anterior horn CVI (Cerebro-Ventricular Index) and Body CVI. 2) Patients with myotonic dystrophy show cerebral atrophy. We carried out the CT scan (GECT/T 8800) on 17 myotonic dystrophy patients and 30 controls. Between the two groups, age and sex were almost matched. In the two groups, we calculated our new indices as well as various indices which have been reported; Huckman number, Bifrontal CVI, Bicaudal CVI, Anterior horn index, Hirajima's index, and Cella-media index. The data were analyzed statistically. The ventricular dilatation of myotonic dystrophy patients is more definite with Anterior horn CVI, Bicaudal CVI and Body CVI (p<0.01). These indices have higher correlations with the ventricular area (about 0.9). (J.P.N.)

  12. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  13. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  14. An assessment of pulmonary emphysema in smokers using CT scan

    International Nuclear Information System (INIS)

    Satoh, Katashi; Kobayashi, Takuya; Misao, Takahiko

    1999-01-01

    We assessed the relationship between PE and smoking in 639 cases (411 males and 228 females with age ranged 21-86 years) who underwent CT scans during the period, from December 1997 to December 1998, under suspicion of respiratory disease on chest radiograph or some respiratory complaints. PE was diagnosed by the existence of low attenuation areas in CT scan and not by pulmonary function tests. CT was performed with 10 mm collimation in a standard algorithm. PE, regardless of the grade, was seen: in 189 out of 348 (54.3%) cases in male smokers and in only 2 out of 63 (3.2%) cases in male non-smokers; and in 5 out of 25 (20.0%) female smokers and in 4 out of 203 (2.0%) female non-smokers. PE was observed in more than half of male smokers. High incidence of PE was also observed in even younger generation, and its severity progresses with advancing age and increasing smoking index. (author)

  15. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation

    Energy Technology Data Exchange (ETDEWEB)

    Landry, Guillaume, E-mail: g.landry@lmu.de [Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748, Germany and Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377 (Germany); Nijhuis, Reinoud; Thieke, Christian; Reiner, Michael; Ganswindt, Ute; Belka, Claus [Department of Radiation Oncology, Ludwig-Maximilians-University, Munich D81377 (Germany); Dedes, George; Handrack, Josefine; Parodi, Katia [Department of Medical Physics, Ludwig-Maximilians-University, Munich D85748 (Germany); Janssens, Guillaume; Orban de Xivry, Jonathan [ICTEAM, Université Catholique de Louvain, Louvain-La-Neuve B1348 (Belgium); Kamp, Florian; Wilkens, Jan J. [Department of Radiation Oncology, Technische Universität München, Klinikum rechts der Isar, Munich D81675, Germany and Physik-Department, Technische Universität München, Garching D85748 (Germany); Paganelli, Chiara; Riboldi, Marco; Baroni, Guido [Dipartimento di Elettronica Informazione e Bioingegneria, Politecnico di Milano, Milan 20133 (Italy)

    2015-03-15

    Purpose: Intensity modulated proton therapy (IMPT) of head and neck (H and N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigated deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. Methods: Datasets of six H and N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT

  16. Computed tomographic (CT) scans in cerebral palsy (CP)

    International Nuclear Information System (INIS)

    Kolawole, T.M.; Patel, P.J.; Mahdi, A.H.

    1989-01-01

    The CT findings in 120 cerebral palsied children are analysed. The 72.5% positive findings are correlated with the clinical types, as well as the aetiological basis for the cerebral palsy. The spastic type, 83.3% of the total number of children, had the highest positive findings. The yield was increased in children with seizures (91.3%) and those in the postnatal group (90%), as well as those with birth trauma and neonatal asphyxia (94%). The findings were those of atrophy in 30.8%, hydrocephalus, in 10%, infarct in 11.6%, porencephaly in 8.3% and others. The atropic changes and their patterns are explained. Treatable lesions, such as tumour, hydrocephalus, subdural haematoma, porencephaly and hygroma were identified in 22.5% of cases. It is concluded that CT scan is definitely efficacious in the management of cerebral palsied children. (orig.)

  17. Optimal CT scanning parameters for commonly used tumor ablation applicators

    International Nuclear Information System (INIS)

    Eltorai, Adam E.M.; Baird, Grayson L.; Monu, Nicholas; Wolf, Farrah; Seidler, Michael; Collins, Scott; Kim, Jeomsoon; Dupuy, Damian E.

    2017-01-01

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  18. Optimal CT scanning parameters for commonly used tumor ablation applicators

    Energy Technology Data Exchange (ETDEWEB)

    Eltorai, Adam E.M. [Warren Alpert Medical School of Brown University (United States); Baird, Grayson L. [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Lifespan Biostatistics Core (United States); Rhode Island Hospital (United States); Monu, Nicholas; Wolf, Farrah; Seidler, Michael [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States); Collins, Scott [Department of Diagnostic Imaging (United States); Rhode Island Hospital (United States); Kim, Jeomsoon [Department of Medical Physics (United States); Rhode Island Hospital (United States); Dupuy, Damian E., E-mail: ddupuy@comcast.net [Department of Diagnostic Imaging (United States); Warren Alpert Medical School of Brown University (United States); Rhode Island Hospital (United States)

    2017-04-15

    Highlights: • This study aimed to determine optimal scanning parameters for commonly-used tumor ablation applicators. • The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance. • Optimum combinations for each probe are provided. - Abstract: Purpose: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. Materials and methods: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440 mA with 5 mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. Results: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p = <0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. Conclusion: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.

  19. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  20. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    Science.gov (United States)

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  1. Dosimetry study using head dummy in computed tomography scans

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Do Carmo S, P.; Prata M, A.

    2017-10-01

    The concern in the amounts of radiation doses deposited in the patients is still great because the computed tomography (CT) exams are currently the ones that reach the highest levels of radiation deposited in the population. Brazilian legislation regulates the levels of doses deposited in patients since it is limited to estimating a maximum amount, depending on the region of the body to be exposed. Therefore is necessary to determine the amount of dose that is deposited in patients depending on the routine protocols used in the radio diagnosis services and thus, propose an optimization of these under the principles referring to dose limitation, optimization of radiological protection and of course, the justification of the practices. Experiments were conducted to determine the dose profile for routine head exams in an adult patient, using a physical simulator object of polymethylmethacrylate (PMMA) in cylindrical format with 4 peripheral orifices and one central one. Strips of radiochromic film were introduced in each of the holes to record the dose profile in each region and thus determine the amount of dose deposited in the entire volume of the simulator object. A General Electric 64-channel tomograph, typical of the radiology service, was used for voltages of 80, 100 and 120 kV with a fixed current of 200 ma, finding dose levels between 6.24 and 23.73 mGy. Noise analysis of the images was performed, finding that all of them met the acceptable diagnostic parameters. An optimized protocol is proposed for head CT exams with a voltage of 80 kV for images with a noise index of 0.5%. (Author)

  2. Evaluation of normal brain CT scan in Korean

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Suh, J. H.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1981-06-15

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm ({+-} 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm ({+-} 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age.

  3. Evaluation of normal brain CT scan in Koreans

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodiagnostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normartive criteria in Koreans for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5mm( ± 0.3), more wider in male (male; 5.2mm, female; 4.5mm) and increased with age. 3. Mean width of fourth ventricle is 13mm( ± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  4. Evaluation of normal brain CT scan in Korean

    International Nuclear Information System (INIS)

    Lee, Y. H.; Suh, J. H.; Park, C. Y.

    1981-01-01

    The safety of procedure combined with wealth of information have resulted in rapid acceptance of CT as a practical and reliable neurodignostic technique. To understand the alternation in tissue density and associated displacement and distortion caused by pathologic lesion in CT, it is necessary to have clear understanding of normal anatomical landmark. For the purpose of establishing normative criteria in Korean for comparative diagnosis, 500 normal CT scan without neurologic sign were studied. The brief results are follows; 1. Among many ventricular index measured for lateral ventricle, the bifrontal CVI is more sensitive and easily determined. Ventricular size increased with age, especially after 6th decade but no difference with sex. 2. Mean width of third ventricle is 5 mm (± 0.3), more wider in male (male; 5.2 mm, female; 4.5 mm) and increased with age. 2. Mean width of fourth ventricle is 13 mm (± 1.3), without difference in age and sex. The shape of ventricle is variable form of triangle. The position of ventricle relative to Twining's line can be determined, so ratio of distance from tuberculum sellae to center of fourth ventricle to Twining's line is between 0.46-0.52. 4. Suprasellar cistern is visible in 89.7% of scan and shape of cistern is found to be pentagonal (73.3%), hexagonal (23.0%) and tetragonal (3.7%). 5. Choroid plexus can be identified in 90% and asymmetrical in 4%. 45% of identified choroid plexus can be visible on scan without contrast enhancement, and more frequently visible in older age

  5. Leigh's subacute necrotizing encephalomyelopathy: Possible diagnosis by CT scan

    International Nuclear Information System (INIS)

    Chi, J.G.; Yoo, H.W.; Chang, K.H.; Kim, C.W.; Moon, H.R.; Ko, K.W.

    1981-01-01

    A 28-month-old Korean girl developed a rapidly progressive disease, characterized by disturbance of consciousness, tremor, nystagmus, ophthalmoplegia, irregular deep respiration and vomiting. The patient succumbed 2 weeks after the onset of the illness. CT scan disclosed bilaterally symmetrical, low density lesions in the white matter and lateral basal ganglia. Distinctive histopathological findings at postmortem included spongiotic necrosis of the neuropil, marked capillary vascularity, persistence of relatively normal neurons in severely damaged zones, and comparatively little astrocytosis. The bilaterally symmetrical distribution of these changes in the putamen and periaqueductal gray matter of the midbrain were compatible with Leigh's disease. (orig.)

  6. Treatment of alzheimer disease with CT scans - a case report

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M. [Cuttler & Associates Inc., Vaughan, Ontario (Canada); Moore, E.R. [Dow Chemical Co., Midland, MI (United States); Hosfeld, V.D. [MidMichigan Health, Midland, MI (United States); Nadolski, D.L. [Midland Internal Medicine Associates PC, Midland, MI (United States)

    2016-03-15

    Alzheimer disease (AD) primarily affects older adults. This neurodegenerative disorder is the most common cause of dementia and is a leading source of their morbidity and mortality. U.S. patient care costs are about 200 billion dollars and will more than double by 2040. This case report describes the remarkable improvement of an advanced AD patient in hospice, who received five CT scans of the brain, about 40 mGy each, over a period of three months. The mechanism appears to be radiation-induced up-regulation of the patient's adaptive protection systems against AD, which partially restored cognition, memory, speech, movement, and appetite. (author)

  7. Treatment of alzheimer disease with CT scans - a case report

    International Nuclear Information System (INIS)

    Cuttler, J.M.; Moore, E.R.; Hosfeld, V.D.; Nadolski, D.L.

    2016-01-01

    Alzheimer disease (AD) primarily affects older adults. This neurodegenerative disorder is the most common cause of dementia and is a leading source of their morbidity and mortality. U.S. patient care costs are about 200 billion dollars and will more than double by 2040. This case report describes the remarkable improvement of an advanced AD patient in hospice, who received five CT scans of the brain, about 40 mGy each, over a period of three months. The mechanism appears to be radiation-induced up-regulation of the patient's adaptive protection systems against AD, which partially restored cognition, memory, speech, movement, and appetite. (author)

  8. Primary laryngeal tuberculosis mimicking laryngeal carcinoma: CT scan features

    International Nuclear Information System (INIS)

    El Kettani, N Ech-Cherif; El Hassani, MR; Chakir, N; Jiddane, M

    2010-01-01

    Laryngeal tuberculosis is a rare disease. It is almost always associated with pulmonary tuberculosis. It occurs generally in adults without BCG vaccination or in cases of the acquired immune deficiency syndrome. On laryngoscopy and imaging, it often simulates laryngeal carcinoma, and confirmation is always histological. We report the case of a 36-year-old man who presented to our hospital with dysphonia and dysphagia. Laryngoscopy revealed a lesion of the left vocal cord and the ventricular strip. CT scan found focal, regular thickening of the left vocal cord, associated with irregular thickening of the posterior laryngeal wall. A biopsy confirmed the diagnosis of tuberculosis

  9. Diagnosis of anemia on CT scans of the thorax

    International Nuclear Information System (INIS)

    Corcoran, H.L.; Cook, D.E.; Proto, A.V.

    1986-01-01

    Visualization of the interventricular septum on nonenhanced CT scans of the thorax of patients with anemia has been illustrated in the literature and explained in terms of a density differential between the cardiac musculature and the blood of anemic patients (blood with a low hemoglobin level). There are no data on the frequency of visualization of the walls of the cardiac chambers, the aorta and its branches, the superior and inferior venae cavae, the brachiocephalic veins, the azygos arch, and so forth. Experience with 50 patients is reported in terms of the foregoing. Findings are correlated with the severity of the anemia, thereby indicating how commonly one may encounter such an appearance

  10. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  11. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    International Nuclear Information System (INIS)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y.; Hibbard, Roberta A.; Hicks, Ralph A.

    2017-01-01

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  12. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Hibbard, Roberta A.; Hicks, Ralph A. [Indiana University School of Medicine, Department of Pediatrics, Section of Child Protection Programs, Indianapolis, IN (United States)

    2017-07-15

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  13. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  14. The use of brain CT Scan in craniocerebral trauma with Glasgow coma scale scores of 13 – 15 in Dr. Cipto Mangunkusumo Hospital 1999-2001

    Directory of Open Access Journals (Sweden)

    Jofizal Jannis

    2004-09-01

    Full Text Available There is still a controversy among the neurologists whether brain CT scan must be performed on the mild head trauma patients. This study was executed to find out the correlation between the brain CT scan image findings and its clinical impairment among the mild head trauma patients with Glasgow coma scale (GCS score of 13 to 15. The study was a retrospective study by analyzing the uniform medical records of the head trauma patients hospitalized at the Neurology ward of Dr. Cipto Mangunkusumo Hospital within the period of 1999 to 2001. During that period 1,663 patients were hospitalized due to head trauma, and 1,166 of them (70.1 % were suffered from mild head trauma patients with GCS score of 13-15. Among those with brain CT scan examinations (N: 271, the neurological abnormalities were found on 144 (53.1% of patients, consisted of cerebral edema (11,4%, intracerebral hemorrhage (5.5%, epidural hemorrhage (16.2%, subdural hemorrhage (18.1%, subarachnoid hemorrhage (5.5%, and combination (13.8%. The further analysis showed that cranial nerves disturbance, amnesia, loss of conciousness for more than 10 minutes, and vomiting are significantly correlated to the brain CT scan abnormality. Combination of the above four clinical signs and symptoms have sensitivity of 90 % in predicting brain insults. This findings may be used as a simple set of clinical criteria for identifying mild head trauma patients who need undergo CT scan examination. (Med J Indones 2004; 13: 156-60 Keywords: mild head injury, brain CT scan

  15. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  16. Reducing radiation dose in adult head CT using iterative reconstruction. A clinical study in 177 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaul, D. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiology; Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiation Oncology; Kahn, J.; Huizing, L.; Wiener, E.; Grupp, U.; Boening, G.; Streitparth, F. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiology; Ghadjar, P. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiation Oncology; Renz, D.M. [Jena University Hospital (Germany). Dept. of Radiology

    2016-02-15

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n=71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n=86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n=74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n=20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n=20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p < 0.0001), respectively. Group B1 and group C1/2 also showed significantly reduced quantitative and qualitative image quality parameters. In group B2, quantitative measures were comparable to group A, and qualitative scores were lower compared to group A but higher compared to group B1. Diagnostic confidence grading showed groups B1/2 to be adequate for everyday clinical practice. Group C2 was considered acceptable for follow-up imaging of severe acute events such as bleeding or subacute stroke. Conclusion: Use of ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up.

  17. Reducing radiation dose in adult head CT using iterative reconstruction. A clinical study in 177 patients

    International Nuclear Information System (INIS)

    Kaul, D.; Charite School of Medicine and University Hospital, Berlin; Kahn, J.; Huizing, L.; Wiener, E.; Grupp, U.; Boening, G.; Streitparth, F.; Ghadjar, P.; Renz, D.M.

    2016-01-01

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n=71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n=86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n=74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n=20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n=20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p < 0.0001), respectively. Group B1 and group C1/2 also showed significantly reduced quantitative and qualitative image quality parameters. In group B2, quantitative measures were comparable to group A, and qualitative scores were lower compared to group A but higher compared to group B1. Diagnostic confidence grading showed groups B1/2 to be adequate for everyday clinical practice. Group C2 was considered acceptable for follow-up imaging of severe acute events such as bleeding or subacute stroke. Conclusion: Use of ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up.

  18. Light scattering in optical CT scanning of Presage dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y; Adamovics, J; Cheeseborough, J C; Chao, K S; Wuu, C S, E-mail: yx2010@columbia.ed

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS' optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  19. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  20. SU-F-SPS-03: Direct Measurement of Organ Doses Resulting From Head and Cervical Spine Trauma CT Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Carranza, C; Lipnharski, I; Quails, N; Correa, N; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: This retrospective study analyzes the exposure history of emergency department (ED) patients undergoing head and cervical spine trauma computed tomography (CT) studies. This study investigated dose levels received by trauma patients and addressed any potential concerns regarding radiation dose issues. Methods: Under proper IRB approval, a cohort of 300 trauma cases of head and cervical spine trauma CT scans received in the ED was studied. The radiological image viewing software of the hospital was used to view patient images and image data. The following parameters were extracted: the imaging history of patients, the reported dose metrics from the scanner including the volumetric CT Dose Index (CTDIvol) and Dose Length Product (DLP). A postmortem subject was scanned using the same scan techniques utilized in a standard clinical head and cervical spine trauma CT protocol with 120 kVp and 280 mAs. The CTDIvol was recorded for the subject and the organ doses were measured using optically stimulated luminescent (OSL) dosimeters. Typical organ doses to the brain, thyroid, lens, salivary glands, and skin, based on the cadaver studies, were then calculated and reported for the cohort. Results: The CTDIvol reported by the CT scanner was 25.5 mGy for the postmortem subject. The average CTDIvol from the patient cohort was 34.1 mGy. From these metrics, typical average organ doses in mGy were found to be: Brain (44.57), Thyroid (33.40), Lens (82.45), Salivary Glands (61.29), Skin (47.50). The imaging history of the cohort showed that on average trauma patients received 26.1 scans over a lifetime. Conclusion: The average number of scans received on average by trauma ED patients shows that radiation doses in trauma patients may be a concern. Available dose tracking software would be helpful to track doses in trauma ED patients, highlighting the importance of minimizing unnecessary scans and keeping doses ALARA.

  1. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Sivit, C.J. [Department of Radiology, Rainbow Babies and Children' s Hospital of the University Hospitals of Cleveland and Case Western Reserve School of Medicine, 11100 Euclid Avenue, Cleveland, OH (United States)

    2000-02-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  2. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    International Nuclear Information System (INIS)

    Sivit, C.J.

    2000-01-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  3. An investigation into CT radiation dose variations for head examinations on matched equipment

    International Nuclear Information System (INIS)

    Zarb, Francis; Foley, Shane; Toomey, Rachel; Rainford, Louise; Holm, Susanne; Evanoff, Michael G.

    2016-01-01

    This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n = 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDI vol -mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p ≤ 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC AUC 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality. (authors)

  4. Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Peroni, Marta, E-mail: marta.peroni@mail.polimi.it [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Ciardo, Delia [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Spadea, Maria Francesca [Department of Experimental and Clinical Medicine, Universita degli Studi Magna Graecia, Catanzaro (Italy); Riboldi, Marco [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Comi, Stefania; Alterio, Daniela [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Baroni, Guido [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Orecchia, Roberto [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Universita degli Studi di Milano, Milano (Italy); Medical Department, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy)

    2012-11-01

    Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

  5. Automatic segmentation and online virtualCT in head-and-neck adaptive radiation therapy.

    Science.gov (United States)

    Peroni, Marta; Ciardo, Delia; Spadea, Maria Francesca; Riboldi, Marco; Comi, Stefania; Alterio, Daniela; Baroni, Guido; Orecchia, Roberto

    2012-11-01

    The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Head-facial hemangiomas studied with scanning electron microscopy.

    Science.gov (United States)

    Cavallotti, Carlo; Cavallotti, Chiara; Giovannetti, Filippo; Iannetti, Giorgio

    2009-11-01

    Hemangiomas of the head or face are a frequent vascular pathology, consisting in an embryonic dysplasia that involves the cranial-facial vascular network. Hemangiomas show clinical, morphological, developmental, and structural changes during their course. Morphological, structural, ultrastructural, and clinical characteristics of head-facial hemangiomas were studied in 28 patients admitted in our hospital. Nineteen of these patients underwent surgery for the removal of the hemangiomas, whereas 9 patients were not operated on. All the removed tissues were transferred in our laboratories for the morphological staining. Light microscopy, transmission electron microscopy, and scanning electron microscopy techniques were used for the observation of all microanatomical details. All patients were studied for a clinical diagnosis, and many were subjected to surgical therapy. The morphological results revealed numerous microanatomical characteristics of the hemangiomatous vessels. The observation by light microscopy shows the afferent and the efferent vessels for every microhemangioma. All the layers of the arterial wall are uneven. The lumen of the arteriole is entirely used by a blood clot. The observation by transmission electron microscopy shows that it was impossible to see the limits of the different layers (endothelium, medial layer, and adventitia) in the whole wall of the vessels. Moreover, both the muscular and elastic components are disarranged and replaced with connective tissue. The observation by scanning electron microscopy shows that the corrosion cast of the hemangioma offers 3 periods of filling: initially with partial filling of the arteriolar and of the whole cast, intermediate with the entire filling of the whole cast (including arteriole and venule), and a last period with a partial emptying of the arteriolar and whole cast while the venule remains totally injected with resin. Our morphological results can be useful to clinicians for a precise

  7. Standardised tumour, node and metastasis reporting of oncology CT scans

    International Nuclear Information System (INIS)

    Gormly, K. L. M.

    2009-01-01

    Full text: The oncology CT report is a vital piece of communication between the radiologist and the treating clinician and often determines patient management. The use of a standardised report that follows the tumour, node and metastasis (TNM) structure makes it easier for the radiologist to include all of the necessary information in an easy-to-read format. Presenting the results under the headings of primary tumour, lymph nodes, metastases, and other findings follows a similar pattern to that used by pathologists and also follows the thought process of the treating clinician. Standardised templates for TNM-based oncology CT reports were introduced into public and private institutions. An audit of 199 reports demonstrated a significant increase in the presence of measurements and conclusions in the template reports. While there was a non-significant increase in the use of correct Response Evaluation Criteria In Solid Tumours terminology for template reports, there was an improved attempt to describe the disease response. Saving measurements as a summary series on PACS also assists follow-up reporting

  8. Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke

    International Nuclear Information System (INIS)

    Fahmi, F.; Beenen, L.F.M.; Streekstra, G.J.; Janssen, N.Y.; Jong, H.W. de; Riordan, A.; Roos, Y.B.; Majoie, C.B.; Bavel, E. van; Marquering, H.A.

    2013-01-01

    Objective: Computed Tomography Perfusion (CTP) is a promising tool to support treatment decision for acute ischemic stroke patients. However, head movement during acquisition may limit its applicability. Information of the extent of head motion is currently lacking. Our purpose is to qualitatively and quantitatively assess the extent of head movement during acquisition. Methods: From 103 consecutive patients admitted with suspicion of acute ischemic stroke, head movement in 220 CTP datasets was qualitatively categorized by experts as none, minimal, moderate, or severe. The movement was quantified using 3D registration of CTP volume data with non-contrast CT of the same patient; yielding 6 movement parameters for each time frame. The movement categorization was correlated with National Institutes of Health Stroke Scale (NIHSS) score and baseline characteristic using multinomial logistic regression and student's t-test respectively. Results: Moderate and severe head movement occurred in almost 25% (25/103) of all patients with acute ischemic stroke. The registration technique quantified head movement with mean rotation angle up to 3.6° and 14°, and mean translation up to 9.1 mm and 22.6 mm for datasets classified as moderate and severe respectively. The rotation was predominantly in the axial plane (yaw) and the main translation was in the scan direction. There was no statistically significant association between movement classification and NIHSS score and baseline characteristics. Conclusions: Moderate or severe head movement during CTP acquisition of acute stroke patients is quite common. The presented registration technique can be used to automatically quantify the movement during acquisition, which can assist identification of CTP datasets with excessive head movement

  9. Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Fahmi, F., E-mail: f.fahmi@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.f.beenen@amc.uva.nl [Department of Radiology, AMC, Amsterdam (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Janssen, N.Y., E-mail: n.n.janssen@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Jong, H.W. de, E-mail: H.W.A.M.deJong@umcutrecht.nl [Department of Radiology, UMC Utrecht, 3584CX, Utrecht (Netherlands); Riordan, A., E-mail: alan.riordan@gmail.com [Department of Radiology, UMC Utrecht, 3584CX, Utrecht (Netherlands); Roos, Y.B., E-mail: y.b.roos@amc.uva.nl [Department of Neurology, AMC, Amsterdam (Netherlands); Majoie, C.B., E-mail: c.b.majoie@amc.uva.nl [Department of Radiology, AMC, Amsterdam (Netherlands); Bavel, E. van, E-mail: e.vanbavel@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Marquering, H.A., E-mail: h.a.marquering@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands)

    2013-12-01

    Objective: Computed Tomography Perfusion (CTP) is a promising tool to support treatment decision for acute ischemic stroke patients. However, head movement during acquisition may limit its applicability. Information of the extent of head motion is currently lacking. Our purpose is to qualitatively and quantitatively assess the extent of head movement during acquisition. Methods: From 103 consecutive patients admitted with suspicion of acute ischemic stroke, head movement in 220 CTP datasets was qualitatively categorized by experts as none, minimal, moderate, or severe. The movement was quantified using 3D registration of CTP volume data with non-contrast CT of the same patient; yielding 6 movement parameters for each time frame. The movement categorization was correlated with National Institutes of Health Stroke Scale (NIHSS) score and baseline characteristic using multinomial logistic regression and student's t-test respectively. Results: Moderate and severe head movement occurred in almost 25% (25/103) of all patients with acute ischemic stroke. The registration technique quantified head movement with mean rotation angle up to 3.6° and 14°, and mean translation up to 9.1 mm and 22.6 mm for datasets classified as moderate and severe respectively. The rotation was predominantly in the axial plane (yaw) and the main translation was in the scan direction. There was no statistically significant association between movement classification and NIHSS score and baseline characteristics. Conclusions: Moderate or severe head movement during CTP acquisition of acute stroke patients is quite common. The presented registration technique can be used to automatically quantify the movement during acquisition, which can assist identification of CTP datasets with excessive head movement.

  10. Head-to-head comparison between {sup 18}F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela [University Hospitals of Strasbourg, Department of Radiology, Strasbourg (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Goichot, Bernard; Chabrier, Gerard [University Hospitals of Strasbourg, Department of Internal Medicine, Strasbourg (France); Petit-Thomas, Julie; Charpiot, Anne [University Hospitals of Strasbourg, Department of Otolaryngology and Maxillofacial Surgery, Strasbourg (France); Averous, Gerlinde [University Hospitals of Strasbourg, Department of Pathology, Strasbourg (France); Imperiale, Alessio [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Hautepierre University Hospital, Biophysics and Nuclear Medicine, Strasbourg Cedex (France)

    2017-06-15

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of {sup 18}F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both {sup 18}F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further {sup 18}F-FDOPA PET/CT and/or MRA. {sup 18}F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. {sup 18}F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. {sup 18}F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, {sup 18}F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. {sup 18}F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that {sup 18}F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when {sup 68

  11. Head-to-head comparison between "1"8F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    International Nuclear Information System (INIS)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques; Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela; Taieb, David; Goichot, Bernard; Chabrier, Gerard; Petit-Thomas, Julie; Charpiot, Anne; Averous, Gerlinde; Imperiale, Alessio

    2017-01-01

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of "1"8F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both "1"8F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further "1"8F-FDOPA PET/CT and/or MRA. "1"8F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. "1"8F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. "1"8F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, "1"8F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. "1"8F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that "1"8F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when "6"8Ga-labeled somatostatin analogues are

  12. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  13. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT

    International Nuclear Information System (INIS)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W.; Koester, M.

    1999-01-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [de

  14. Dual purpose QA tool developed for teletherapy unit and CT scan in SNDH

    International Nuclear Information System (INIS)

    Shilvant, D.V.; Tamane, C.J.; Pangam, S.B.; Raees, M.D.; Aynoor, S.K.; Pol, P.S.; Verghese, Aju; Ghorpade, C.J.

    2007-01-01

    To make a simple device used in Teletherapy unit and CT scan for depth data measurement. The accurate depth data is essential and very important factor for precise treatment in SAD isocentric setup calculation. In CT scan based treatment planning, the calculation obtained is from the depth given by the CT scan. The success of treatment depends on the same parameters in treatment unit matched with diagnostic CT scan data. To check the depth parameters in both CT scan and Teletherapy unit we have developed a single QA tool in our hospital. As this tool is precise, handy and easily accessible the results obtained from it assures the quality of Teletherapy unit as well as CT scan depth data. This small device resulted data helps a lot in calculations of complicated SAD setup in Telecobalt and also useful in recent new treatment modalities such as IMRT, micro MLC, etc

  15. Nonrigid Image Registration for Head and Neck Cancer Radiotherapy Treatment Planning With PET/CT

    International Nuclear Information System (INIS)

    Ireland, Rob H.; Dyker, Karen E.; Barber, David C.; Wood, Steven M.; Hanney, Michael B.; Tindale, Wendy B.; Woodhouse, Neil; Hoggard, Nigel; Conway, John; Robinson, Martin H.

    2007-01-01

    Purpose: Head and neck radiotherapy planning with positron emission tomography/computed tomography (PET/CT) requires the images to be reliably registered with treatment planning CT. Acquiring PET/CT in treatment position is problematic, and in practice for some patients it may be beneficial to use diagnostic PET/CT for radiotherapy planning. Therefore, the aim of this study was first to quantify the image registration accuracy of PET/CT to radiotherapy CT and, second, to assess whether PET/CT acquired in diagnostic position can be registered to planning CT. Methods and Materials: Positron emission tomography/CT acquired in diagnostic and treatment position for five patients with head and neck cancer was registered to radiotherapy planning CT using both rigid and nonrigid image registration. The root mean squared error for each method was calculated from a set of anatomic landmarks marked by four independent observers. Results: Nonrigid and rigid registration errors for treatment position PET/CT to planning CT were 2.77 ± 0.80 mm and 4.96 ± 2.38 mm, respectively, p = 0.001. Applying the nonrigid registration to diagnostic position PET/CT produced a more accurate match to the planning CT than rigid registration of treatment position PET/CT (3.20 ± 1.22 mm and 4.96 ± 2.38 mm, respectively, p = 0.012). Conclusions: Nonrigid registration provides a more accurate registration of head and neck PET/CT to treatment planning CT than rigid registration. In addition, nonrigid registration of PET/CT acquired with patients in a standardized, diagnostic position can provide images registered to planning CT with greater accuracy than a rigid registration of PET/CT images acquired in treatment position. This may allow greater flexibility in the timing of PET/CT for head and neck cancer patients due to undergo radiotherapy

  16. Varifocal mirror display of organ surfaces from CT scans

    International Nuclear Information System (INIS)

    Pizer, S.M.; Fuchs, H.; Bloomberg, S.H.; Li Ching Tsai; Heinz, E.R.

    1982-01-01

    A means will be presented of constructing a powerful varifocal mirror 3D display system with limited cost based on an ordinary color video digital display system. The importance of dynamic interactive control of the display of these images will be discussed; in particular, the design and usefulness of a method allowing real-time user-controlled motion of the 3D object being displayed will be discussed. Also, an effective method will be described of presenting images made of surfaces by the straightforward, automatic calculation of 3D edge strength, the ordering of the resulting voxels by edge strength, and the 3D grey-scale display of the top voxels on this ordered list. The application of these ideas to the 3D display of the intimal wall of the region of bifurcation of the carotid artery from 12-24 CT scans of the neck will be discussed

  17. Exploring miniature insect brains using micro-CT scanning techniques

    Science.gov (United States)

    Smith, Dylan B.; Bernhardt, Galina; Raine, Nigel E.; Abel, Richard L.; Sykes, Dan; Ahmed, Farah; Pedroso, Inti; Gill, Richard J.

    2016-01-01

    The capacity to explore soft tissue structures in detail is important in understanding animal physiology and how this determines features such as movement, behaviour and the impact of trauma on regular function. Here we use advances in micro-computed tomography (micro-CT) technology to explore the brain of an important insect pollinator and model organism, the bumblebee (Bombus terrestris). Here we present a method for accurate imaging and exploration of insect brains that keeps brain tissue free from trauma and in its natural stereo-geometry, and showcase our 3D reconstructions and analyses of 19 individual brains at high resolution. Development of this protocol allows relatively rapid and cost effective brain reconstructions, making it an accessible methodology to the wider scientific community. The protocol describes the necessary steps for sample preparation, tissue staining, micro-CT scanning and 3D reconstruction, followed by a method for image analysis using the freeware SPIERS. These image analysis methods describe how to virtually extract key composite structures from the insect brain, and we demonstrate the application and precision of this method by calculating structural volumes and investigating the allometric relationships between bumblebee brain structures. PMID:26908205

  18. Intrapartum FHR monitoring and neonatal CT brain scan

    International Nuclear Information System (INIS)

    Takahashi, Yoshiki; Ukita, Masahiko; Nakada, Eizo

    1982-01-01

    The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no variability resulted in severe neonatal brain edema. Four cases with variable deceleration and increased variability resulted in mild neonatal brain edema. Two cases with late deceleration and decreased variability resulted in no neonatal brain edema. (author)

  19. Focal hepatic steatosis: ultrasound and CT scan features may mimick carcinoma of the liver

    International Nuclear Information System (INIS)

    Monnin, J.L.; Blanc, F.; Guiry, P.; Bruel, J.M.; Monnin, E.; Ciurana, A.J.

    1988-01-01

    Ultrasound and CT scan features of focal hepatic steatosis (FHS) may closely resemble those of primary or secondary malignant hepatic tumors. Three cases of FHS in chronic alcoholics are reported. In two cases, the area of steatosis was hyperechogenic upon ultrasonography. In all three patients, CT scan demonstrated a hypodense image, with poor enhancement following opacification and no mass effect. Diagnosis of FHS was ascertained upon hepatic biopsy under CT scan guidance in all three patients [fr

  20. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob; Yang, Jie

    2014-01-01

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm 3 Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT

  1. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Yang, Jie [Pinnacle Health - Fox Chase Regional Cancer Center, Harrisburg, Pennsylvania 17109 (United States)

    2014-09-15

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

  2. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  3. Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Kuang, Anna A.; Schwartz, Daniel L.; Selden, Nathan R.; Stevens, Donna M.; Bardo, Dianna M.E.

    2010-01-01

    Children are exposed to ionizing radiation during pre- and post-operative evaluation for craniofacial surgery. The primary purpose of the study was to decrease effective radiation dose while preserving the diagnostic quality of the study. In this prospective study 49 children were positioned during craniofacial CT (CFCT) imaging with their neck fully extended into an exaggerated sniff position, parallel to the CT gantry, to eliminate the majority of the cervical spine and the thyroid gland from radiation exposure. Image-quality and effective radiation dose comparisons were made retrospectively in age-matched controls (n = 49). When compared to CT scans reviewed retrospectively, the prospective examinations showed a statistically significant decrease in z-axis length by 16% (P < 0.0001) and delivered a reduced effective radiation dose by 18% (P < 0.0001). The subjective diagnostic quality of the exams performed in the prospective arm was maintained despite a slight decrease in the quality of the brain windows. There was statistically significant improvement in the quality of the bone windows and three-dimensional reconstructed images. Altering the position of the head by extending the neck during pediatric craniofacial CT imaging statistically reduces the effective radiation dose while maintaining the diagnostic quality of the images. (orig.)

  4. Frequency of cerebral infarction secondary to head injury and the underlying mechanisms: CT study

    International Nuclear Information System (INIS)

    Fernande-Fresno, L.; Manzanares, R.; Caniego, J.L.; Velasco, M.; Parra, M.L.; Monasterio, F.

    1997-01-01

    To study the frequency of and possible mechanisms producing severe head injury (HI) by serial CT studies. We reviewed brain CT results in 154 HI patients examined over the past 31 months. All of them were hospitalized in the Intensive Care Unit (ICU) presenting coma with Glosgow Coma Scale scores of 9 or under. A first CT scan was performed when the patients arrived in the emergency room and at a least one more was carried out over the following 1 to 6 days. Sixteen of the 154 patients presented ischemic areas of low attenuation in a territory of defined vascular distribution that did not exist in the CT done at admission; the majority of them also had extensive extraaxial or intraaxial hematomas causing a considerable mass effect and cerebral displacement inducing different types of herniation. The vascular territories involved were anterior cerebral artery in five cases, middle cerebral artery in two, posterior cerebral artery in seven lenticulostriate arteries in six, anterior choroidal artery in five, perforating thalamus in six, recurrent artery in one case and superior cerebellar artery in another. In our series, there was a high prevalence (10.4%) of infarcts associated with severe HI; the most common etiopathogenic mechanisms are cerebral displacement accompanied by compression and vessel strain. (Author) 13 refs

  5. Case of pycnodysostosis. Observation of skull by CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Anegawa, Shigetaka; Bekki, Yoshiaki; Furukawa, Yasuhiro; Yokota, Seishi; Torigoe, Ryuichiro

    1987-07-01

    A 13-year-old boy was presented to the Department of Neurosurgery, Saiseikai Fukuoka General Hospital for further examinations concerning abnormal findings in the skull radiogram taken when he struck his head. His physical features showed some characteristics the same as those of pycnodysostosis as follows - proportionate dwarfism, prominent forehead, short spoon-shaped fingers, bilateral exophthalmos. A skull radiogram revealed widely open cranial sutures with no healing of the fracture and craniotomy which was performed for an acute epidural hematoma 6 years ago. Furthermore, the mandible was hypoplastic with a virtural loss of mandibular angle. CT of the soft tissues showed somewhat dilated cortical sulci and ventricles without any structural abnormalities in the brain. CT of bone algorythum revealed specific characteristics of this disease. The paranasal sinuses were quite hypoplastic. Especially in the maxillary sinuses, frontal sinussus and mastoid air cells, none of developments of sinuses were noted, even though the middle and internal ear seemed to be normal. Moreover, the ethomoid and sphenoid sinuses were noted, although their developments were poor. The appearance of skull base was normal, including the inlets and outlets of cranial nerves or vessels and synchondroses. However, the density of the skull base, especially in the diploe, was higher than normal in Hansfield number. Furthermore, detailed measurements of skull base demonstrated that the skull base itself was also dwarfish. In our study, the development of sinuses in bones with intramembranous ossification are worse than that with endochondral ossification. Furthermore, sutures or synchondroses in the skull base were well-developed than those of the convex. So, it is considered that pycnodysostosis must be the neighboring entity of diseases such as achondroplastic dwarfism or cleidocranial dysplasia. (J.P.N.).

  6. A case of intracranial malignant lymphoma with pure akinesia and repeated regression on CT scans

    International Nuclear Information System (INIS)

    Suzuki, Takeo; Yamamoto, Mari; Saitoh, Mitsunori; Aoki, Akira; Imai, Hisamasa; Narabayashi, Hirotaro.

    1984-01-01

    In a case of primary reticulum cell sarcoma in the brain, histologically verified by biopsy, the tumor regressed twice on a CT scan without radiotherapy. The systemic freezing phenomenon was seen as a main clinical symptom. The patient, a 44 year-old male, first complained of decreased livido and festinating speech. He also showed frozen gait, micrographia, a decrease in spontaneity and urinary incontinence. Four months after onset he was hospitalized. Neurological findings on admission revealed freezing of gait, writing, and speech, but there was no weakness of muscles with normal tendon reflexes, and normal muscular tone. In the CT scan on admission, there were high density areas mainly in the head of the right caudate nucleus, the medial deep portion of the right frontal lobe, the right side of the hypothalamus, the anterior thalamus, the globus pallidus. There were also nodular-type enhanced effects in the same areas. Regression of the tumor was seen on the CT scans after administration of betamethasone. The tumor which had again incrased in size regressed spontaneously without the use of steroids after 3 months. Thereafter, the tumor gradually became larger and an open biopsy was perfomed. Histopathological findings showed a reticulum cell sarcoma. There were no findings of systemic malignant lymphoma. Such intracrainal malignant lymphomas showing repeated regression including spontaneous one are very rare in the literature. The freezing phenomenon in this case started with festinating speech and spread to writing and gait. L-DOPA had no effect. This systemic freezing phenomenon was considered to be the same as that in the cases of pure akinesia without rigidity and tremor reported by Narabayashi and Imai, which did not respond to L-DOPA at all. But on the other hand, L-Threo-3, 4-Dihydroxyphenylserine was effective to the frozen gait of this patient. (J.P.N.)

  7. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  8. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  9. Childhood CT scans linked to leukemia and brain cancer later in life

    Science.gov (United States)

    Children and young adults scanned multiple times by computed tomography (CT), a commonly used diagnostic tool, have a small increased risk of leukemia and brain tumors in the decade following their first scan.

  10. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  11. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  12. Radiologic evaluation of orbital index among Ghanaians using CT scan.

    Science.gov (United States)

    Botwe, Benard Ohene; Sule, Derick Seyram; Ismael, Abdul Mumin

    2017-07-11

    Orbital index (OI) expresses the proportion of the orbital height to the orbital width and varies with race, regions within the same race and periods in evolution. This index is useful in forensic medicine, anthropology and surgery. However, the average OI among Ghanaian adults was unknown. The aim of this study was to determine the orbital index of adult Ghanaians and classify them under one of the three predetermined groups. The study design was a retrospective cross-sectional. A systematic random sampling method was used for selecting 350 adult Ghanaian head computed tomography images available from 1 January to 31 December 2015 at KBTH Hospital. The orbital height and orbital width of each orbit were measured on a 3D CT skull. Data was analysed using Microsoft Excel and Statistical Package for Social Sciences version 20. The study had more females than men (167, 47.71%, vs 183, 52.29%). The observed orbital index of Ghanaians in the study was 81.22 ± 4.22. The mean orbital index was 80.52 ± 4.66 in males and 82.15 ± 3.83 in females with their difference being statistically significant (p value forensic medicine for skull classification and also for better surgical approach in neurosurgery as well as cosmetic surgery.

  13. Significance and problems of the dynamic CT scan for the diagnosis and treatment of cerebral infarctions

    International Nuclear Information System (INIS)

    Morita, Akio; Teraoka, Akira

    1985-01-01

    Dynamic CT scan is a very useful method for the diagnosis of cerebral infarctions and other ischemic disorders. We have used this method for 1) the ultra-early stage diagnosis of major infarctions, 2) the detection of the recanalization and the disruption of the blood-brain barrier, and 3) the detection of latent ischemic lesions. In this report we discussed the clinical cases and the usual use of this dynamic CT scan. We used a GE CT/T8800 scanner for dynamic CT scanning. Manual bolus-contrast-medium injection was done simultaneously with the first scanning, and 6 sequential scannings (scan time: 4.8 s; scan interval: 1.4 s) were done on the same slice level. Especially in major infarctions (e.g., MCA occlusion), OM 40 was the most preferred slice. In cases of ultra-early stage infarctions (i.e., no abnormal lesions in non-enhanced CT), we used this dynamic CT scan immediately after the non-enhanced CT; we could thus obtain information on the ischemic lesions and the ischemic degree. After that we repeated this examination on Days 3, 7, and 14 for the evaluation of the recanalization and blood-brain-barrier disruption. In the cases of TIA and impending or progressing strokes, dynamic CT scan could disclose latent ischemic lesions; in there instances, we treated the patients with intensive to prevent the prognosis from worsening. These benefits and also some problems were discussed. (author)

  14. A case of diffuse hemispheric gyral high density on CT scan following acute subdural hematoma in children

    International Nuclear Information System (INIS)

    Kannuki, Seiji; Oi, Shizuo

    1986-01-01

    A case of diffuse hemispheric gyral high density area following acute subdural hematoma was reported. A 2 - 10/12 year-old male was admitted to our hospital in comatous state after head injury by fall. Neurological examination revealed deep coma with anisocoria (R < L), absence of light reflex and positive bilateral Babinski reflex. CT scan disclosed left acute subdural hematoma with remarkable midline shift and tentorial herniation sign. Emergency decompressive craniectomy was performed. Posttraumatic hydrocephalus appeared after 10 days. So, ventriculoperitoneal shunt was done. The patient became gradually improved, but was in appalic state. 23 days after craniectomy, suddenly diffuse hemispheric gyral high density appeared on plain CT scan. In spite of this change, no clinical change was found. This high density spontaneously disappeared 10 days after appearance. Cerebral infarction-like phenomenon on postoperative CT scan of acute subdural hematoma in infants was sometimes reported. This phenomenon was sometimes accompanied with hemorrhagic infarction-like high density on CT scan. Diffuse hemispheric gyral high density was probably a kind of those hemorrhagic infarction-like phenomenon. Possible mechanism of this peculiar high density is discussed on the basis of characteristics of child's cerebral artery and pathophysiology of cerebral infarction. (author)

  15. Protocol optimization in chest CT scans of child

    Energy Technology Data Exchange (ETDEWEB)

    Abrao L, L. T.; Amaral de O, F.; Prata M, A. [Biomedical Engineering Center, Centro Federal de Educacao Tecnologica de Minas Gerais, 30421-169, Belo Horizonte, Minas Gerais (Brazil); Bustos F, M., E-mail: luanaabrao@gmail.com [Universidad Federal de Minas Gerais, Department of Nuclear Engineering, Av. Pres. Antonio Carlos 6627, Pampulha, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    The dissemination of Computed Tomography (CT), a radiodiagnostic technique, has significant increase in the patient dose. In the last years, this technique has shown a high growth due to clinical cases of medical emergencies, neoplasm and pediatric traumas. Dose measurement is important to correlate with the deleterious effects of radiation on the organism and radiation future effects is related with stochastic risks due to tissue radiosensitivity, allied to the life expectancy of the child. In this work, a cylindrical phantom, representing an adult chest made of polymethylmethacrylate (PMMA), was used and a new born chest phantom with a shape oblong was developed based on the dimensions of a typical newborn. In a Ge CT scanner, Discovery model, with 64 channels, the central slice of the phantoms were irradiated successively in order to obtain dose measurements using an ionizing pencil camera. Based in the measurements, dose index was calculated (CTDI{sub vol}). The radiological service chest protocol using a voltage of 120 kV was used for scanning 10 cm of the central area of the adult and newborn phantom, in helical mode. An acquisition of images was performed using this radiological service chest protocol to compare with the protocol optimized. In the newborn phantom was also used protocols optimized using a voltage of 120 and 80 kV. The voltage of 80 kV has the lowest dose index for the pediatric object phantom. This work allowed the comparison between absorbed dose variations by the pediatric phantom changing the X-ray tube supply voltage. This dose variation has shown how important is specific protocols for children. (Author)

  16. Protocol optimization in chest CT scans of child

    International Nuclear Information System (INIS)

    Abrao L, L. T.; Amaral de O, F.; Prata M, A.; Bustos F, M.

    2017-10-01

    The dissemination of Computed Tomography (CT), a radiodiagnostic technique, has significant increase in the patient dose. In the last years, this technique has shown a high growth due to clinical cases of medical emergencies, neoplasm and pediatric traumas. Dose measurement is important to correlate with the deleterious effects of radiation on the organism and radiation future effects is related with stochastic risks due to tissue radiosensitivity, allied to the life expectancy of the child. In this work, a cylindrical phantom, representing an adult chest made of polymethylmethacrylate (PMMA), was used and a new born chest phantom with a shape oblong was developed based on the dimensions of a typical newborn. In a Ge CT scanner, Discovery model, with 64 channels, the central slice of the phantoms were irradiated successively in order to obtain dose measurements using an ionizing pencil camera. Based in the measurements, dose index was calculated (CTDI vol ). The radiological service chest protocol using a voltage of 120 kV was used for scanning 10 cm of the central area of the adult and newborn phantom, in helical mode. An acquisition of images was performed using this radiological service chest protocol to compare with the protocol optimized. In the newborn phantom was also used protocols optimized using a voltage of 120 and 80 kV. The voltage of 80 kV has the lowest dose index for the pediatric object phantom. This work allowed the comparison between absorbed dose variations by the pediatric phantom changing the X-ray tube supply voltage. This dose variation has shown how important is specific protocols for children. (Author)

  17. Not a NICE CT protocol for the acutely head injured child

    International Nuclear Information System (INIS)

    Willis, A.P.; Latif, S.A.A.; Chandratre, S.; Stanhope, B.; Johnson, K.

    2008-01-01

    Aim: To assess the impact of the introduction of the Birmingham Children's Hospital (BCH) head injury computed tomography (CT) guidelines, when compared with the National Institute of Health and Clinical Excellence (NICE) guidelines, on the number of children with head injuries referred from the Emergency Department (ED) undergoing a CT examination of the head. Material and methods: All children attending BCH ED over a 6-month period with any severity of head injury were included in the study. ED case notes were reviewed and data were collected on a specifically designed proforma. Indications for a CT examination according to both NICE and BCH head injury guidelines and whether or not CT examinations were performed were recorded. Results: A total of 1428 children attended the BCH ED following a head injury in the 6-month period. The median age was 4 years (range 6 days to 15 years) and 65% were boys. Four percent of children were referred for a CT using BCH guidelines and were appropriately examined. If the NICE guidelines had been strictly adhered to a further 8% of children would have undergone a CT examination of the head. All of these children were discharged without complication. The remaining 88% had no indication for CT examination by either BCH or NICE and appropriately did not undergo CT. Conclusions: Adherence to the NICE head injury guidelines would have resulted in a three-fold increase in the total number of CT examinations of the head. The BCH head injury guidelines are both safe and appropriate in the setting of a large children's hospital experienced in the management of children with head injuries

  18. Intercomparison of two dynamic treatment techniques, ring scan and spot scan, for head and neck tumors with the Piotron

    International Nuclear Information System (INIS)

    Takai, M.; Blattmann, H.; Pedroni, E.

    1988-01-01

    An evaluation of the ring scan and the spot scan was made for the pion irradiation of head and neck tumors with the Piotron. For the geometry of the Piotron, with its 60 radially converging beams, two scanning techniques have been developed, ring scan and spot scan. They have different characteristics concerning achievable dose distributions and sensitivity to tissue inhomogenities. The optimized 3-dimensional dose distributions for the treatment with ring scan and spot scan techniques were calculated for two examples of the target volume. The comparison of the dose distributions has shown that the ring scan is better in sparing normal tissues than the spot scan for a simple shape target volume but not for an irregular shape target volume with the present status of the technique. The irradiation time needed for the ring scan is longer, for the present examples three times, than for the spot scan. From the practical view point the spot scan is preferable to the ring scan for the treatment of head and neck tumors with the Piotron

  19. The presence and progression of emphysema in COPD as determined by CT scanning and biomarker expression

    DEFF Research Database (Denmark)

    Coxson, Harvey O; Dirksen, Asger; Edwards, Lisa D

    2013-01-01

    Emphysema is a key contributor to airflow limitation in chronic obstructive pulmonary disease (COPD) and can be quantified using CT scanning. We investigated the change in CT lung density in a longitudinal, international cohort of patients with COPD. We also explored the potential relation between...... emphysema and patient characteristics, and investigated if certain circulating biomarkers were associated with decline in CT lung density....

  20. CT scanning in Australia: a report by the National Health Technology Advisory Panel

    International Nuclear Information System (INIS)

    1988-06-01

    An overview of trends in the usage of CT scanning in Australia is given and the areas of benefit and uncertainty associated with this technology are outlined. Numbers and distribution of CT units, costs of CT services, clinical applications, safety aspects and the effects of new developments are discussed. 54 refs., 5 figs., 18 tabs

  1. Importance of repeated CT scan in Fournier gangrene treatment: clinical case

    International Nuclear Information System (INIS)

    Ignatenco, Sergiu

    2011-01-01

    A patient of 53 years presented fever, swelling and erythema in the perineal region. After computed tomography (CT) was diagnosed Fournier gangrene. After aggressive surgical debridement postoperative evolution was unfavorable. Repeated CT scan trace spread of infection to new areas that led to new surgical debridement on time. Use of CT scan in the postoperative period allows assessment of the effectiveness of surgical debridement and spread of infection. This article presents CT scan images and the most important periods of intraoperative surgical intervention. (authors)

  2. Pediatric CT scan usage in Japan. Results of a hospital survey

    Energy Technology Data Exchange (ETDEWEB)

    Ghotbi, N; Morishita, Mariko; Norimatsu, Nana; Namba, Hiroyuki; Yamashita, Shunichi [Nagasaki Univ., Graduate School of Biomedical Sciences, Nagasaki, Nagasaki (Japan); Ohtsuru, Akira [Nagasaki Univ., Hospital, Takashi Nagai Memorial International Hibakusha Medical Center, Nagasaki, Nagaski (Japan); Ogawa, Yoji; Uetani, Masataka; Moriuchi, Hiroyuki [Nagasaki Univ., Hospital, Nagasaki, Nagasaki (Japan)

    2006-10-15

    The aim of this study was to examine the usage parameters of diagnostic computed tomography (CT) in children because of concerns of possible overuse in Japanese hospitals, including the ''technical'' CT exposure settings and the ''clinical'' grounds for CT requests. We examined the methodology at the radiology department to reduce radiation exposure to children and performed a retrospective study on pediatric CT requests during a 1-year period at Nagasaki University Hospital. The parameters of diagnostic CT usage for minor head trauma and acute appendicitis were studied in detail. CT radiation dose settings are adjusted for children based on guidelines issued by the Japan Radiological Society, with few limitations. CT requests were made for 62% of minor head trauma cases and 76% of cases clinically suspected to be acute appendicitis. These figures are considerably higher than those reported by studies in the United Kingdom, Canada, or the United States. No specific guidelines are advocated regarding CT usage for minor head trauma. The diagnosis of acute appendicitis in children is almost routinely referred for confirmation'' by CT. CT radiation risks to children at Japanese hospitals need to be considered more seriously. Physicians should be encouraged to follow diagnostic algorithms that help avoid unnecessary CT usage in children. (author)

  3. Pediatric CT scan usage in Japan. Results of a hospital survey

    International Nuclear Information System (INIS)

    Ghotbi, N.; Morishita, Mariko; Norimatsu, Nana; Namba, Hiroyuki; Yamashita, Shunichi; Ohtsuru, Akira; Ogawa, Yoji; Uetani, Masataka; Moriuchi, Hiroyuki

    2006-01-01

    The aim of this study was to examine the usage parameters of diagnostic computed tomography (CT) in children because of concerns of possible overuse in Japanese hospitals, including the ''technical'' CT exposure settings and the ''clinical'' grounds for CT requests. We examined the methodology at the radiology department to reduce radiation exposure to children and performed a retrospective study on pediatric CT requests during a 1-year period at Nagasaki University Hospital. The parameters of diagnostic CT usage for minor head trauma and acute appendicitis were studied in detail. CT radiation dose settings are adjusted for children based on guidelines issued by the Japan Radiological Society, with few limitations. CT requests were made for 62% of minor head trauma cases and 76% of cases clinically suspected to be acute appendicitis. These figures are considerably higher than those reported by studies in the United Kingdom, Canada, or the United States. No specific guidelines are advocated regarding CT usage for minor head trauma. The diagnosis of acute appendicitis in children is almost routinely referred for confirmation'' by CT. CT radiation risks to children at Japanese hospitals need to be considered more seriously. Physicians should be encouraged to follow diagnostic algorithms that help avoid unnecessary CT usage in children. (author)

  4. Experimental study of abdominal CT scanning exposal doses adjusted on the basis of pediatric abdominal perimeter

    International Nuclear Information System (INIS)

    Wei Wenzhou; Zhu Gongsheng; Zeng Lingyan; Yin Xianglin; Yang Fuwen; Liu Changsheng

    2006-01-01

    Objective: To optimize the abdominal helical CT scanning parameters in pediatric patients and to reduce its radiation hazards. Methods: 60 canines were evenly grouped into 4 groups on the basis of pediatric abdominal perimeter, scanned with 110,150,190 and 240 mAs, and their qualities of canine CT images were analyzed. 120 pediafric patients with clinic suspected abdominal diseases were divided into 4 groups on the basis of abdominal perimeter, scanned by optimal parameters and their image qualities were analyzed. Results: After CT exposure were reduced, the percentages of total A and B were 90.9 % and 92.0 % in experimental canines and in pediatric patients, respectively. Compared with conventional CT scanning, the exposure and single slice CT dose index weighted (CTDIw) were reduced to 45.8%-79.17%. Conclusion: By adjusted the pediatric helical CT parameters basedon the of pediatric abdominal perimeter, exposure of patient to the hazards of radiation is reduced. (authors)

  5. Comparison of planar scanning and single photon emission computed tomography in the diagnosis of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Feiglin, D.H.I.; Levine, M.; Stulberg, B.; Pflanze, W.; O'Donnell, J.K.; Belhobek, G.H.; Go, R.T.; MacIntyre, W.J.

    1986-01-01

    Thirty-nine patients were investigated for avascular necrosis of the femoral head. All hips were studied by plain x-ray and MR imaging, 70 hips studied by radionuclide bone scanning, and 38 were studied by single photon emission CT (SPECT). Core biopsies of the femoral heads from 32 hips were examined. No one reference standard for noninvasive diagnosis of this disease is available. The sensitivity and specificity of the radionuclide studies with respect to SPECT were 77% and 100%; of SPECT with respect to pathologic confirmation, 100% and 57%; of MR imaging with respect to pathologic studies, 100% and 66%. Pathologic sampling is subject to error and may give false negative results with spuriously low specificities for imaging modalities. SPECT is recommended as the radionuclide imaging procedure of choice for detecting avascular necrosis of the femoral head

  6. Estimation of eye lens dose during brain scans using Gafchromic XR-QA2 film in various multidetector CT scanners

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Jamhale, Shramika H.; Sharma, S.D.; Kumar, Rajesh; Datta, D.; Kulkarni, Arti R.

    2017-01-01

    The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. (authors)

  7. Evaluating applicability of metal artifact reduction algorithm for head and neck radiation treatment planning CT

    International Nuclear Information System (INIS)

    Son, Sang Jun; Park, Jang Pil; Kim, Min Jeong; Yoo, Suk Hyun

    2014-01-01

    The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head and neck radiation treatment planning CT with metal artifact created by dental implant. All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120 kVp, 2 mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). In cases of head and neck phantom, the difference of dose distribution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area

  8. The diagnostic value of PET/CT scanning in patients with cervical cancer

    DEFF Research Database (Denmark)

    Loft, Annika; Berthelsen, Anne Kiil; Roed, Henrik

    2007-01-01

    OBJECTIVE: To investigate the clinical value of PET/CT as a supplement to FIGO staging in patients with cervical cancer stage >or=1B. METHODS: This prospective study included 120 consecutive patients. After staging, a whole-body PET/CT scan was performed and these examinations were divided into two....../CT scanning for newly diagnosed cervical cancer FIGO stage >or=1B has a high sensitivity and specificity, and can be a valuable supplement to the FIGO staging procedure....

  9. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  10. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Seok; Kim, Tae Hyung [Dept. of Radiological Science, Kangwon National University, Chuncheon (Korea, Republic of); Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol [Dept. of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of); Cho, Jae Hwan [Dept. of Radiological Science, Gyeongsan University College, Daegu (Korea, Republic of)

    2012-03-15

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  11. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    International Nuclear Information System (INIS)

    Han, Man Seok; Kim, Tae Hyung; Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol; Cho, Jae Hwan

    2012-01-01

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  12. Correlation between CT perfusion and vascular endothelial growth factor in neoplasm of head and neck

    International Nuclear Information System (INIS)

    Yang Zhiyun; Meng Quanfei; Xu Qiaolan; Li Shurong; Yan Chaogui; Xie Hongbo; Yang Xufeng; Peng Qian; Lai Yingrong

    2007-01-01

    Objective: To investigate the correlation between the CT perfusion and microvessel density (MVD), expression of vascular endothelial growth factor (VEGF) in neoplasm of head and neck. Methods: Eighty-eight lesions of head and neck were scanned by spiral CT. The largest axial surface of the mass was searched on unenhanced imaging, and at this level the dynamic contrast enhanced scan series was acquired. Time-density curves (TDC) were created from circular or oval regions of the interest drawn over the mass, target artery by Toshiba Xpress/SX spiral CT with perfusion functional software. The parameters were measured including: peak height (PH), peak time (PT), mean transit time (MTT), contrast enhancement ratio (RPH), and perfusion flow (PF). Histopathological slides of 35 masses were carefully prepared for the anti-CD34 and VEGF immunohistochemical staining and tumor microvessel density and calculation of VEGF expression scores. The parameters of CT perfusion were correlatively study with MVD and VEGF. Results: (1) The TDC of CT perfusion imaging could be classified into 3 types. The TDC of 53/77 (68.9%) malignant tumors presented the type with rapid ascending and rapid descending after injecting contrast. The TDC of 6/9 malignant lymphomas showed low platform curve o (2)The PF median of thyroid carcinoma was 82. 2(41.0,183.4)ml·min -1 ·100 g -1 . There was significantly difference in the parameters of CT perfusion among thyroid carcinoma and squamous cell cancer (Median 23.8 (7.0, 108.4) ml·min -1 ·100 g -1 ) and lymphomas (Median 24.5 (13.2, 78.6) ml·min -1 ·100 g -1 ). (3) MVD in benign tumors was (44.7±3.4), and in malignant tumors, it is (49.6±14.8). There was no significantly difference in MVD between benign and malignant tumors. High VEGF expression was found in 15 malignant tumors and 1 benign tumors, low VEGF expression was found in 9 malignant tumors and 10 benign tumors. (4)There were no significantly difference in VEGF expression and MVD. There

  13. Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Akram Al-Ibraheem

    2009-01-01

    Full Text Available 18F-FDG PET plays an increasing role in diagnosis and management planning of head and neck cancer. Hybrid PET/CT has promoted the field of molecular imaging in head and neck cancer. This modality is particular relevant in the head and neck region, given the complex anatomy and variable physiologic FDG uptake patterns. The vast majority of 18F-FDG PET and PET/CT applications in head and neck cancer related to head and neck squamous cell carcinoma. Clinical applications of 18F-FDG PET and PET/CT in head and neck cancer include diagnosis of distant metastases, identification of synchronous 2nd primaries, detection of carcinoma of unknown primary and detection of residual or recurrent disease. Emerging applications are precise delineation of the tumor volume for radiation treatment planning, monitoring treatment, and providing prognostic information. The clinical role of 18F-FDG PET/CT in N0 disease is limited which is in line with findings of other imaging modalities. MRI is usually used for T staging with an intense discussion concerning the preferable imaging modality for regional lymph node staging as PET/CT, MRI, and multi-slice spiral CT are all improving rapidly. Is this review, we summarize recent literature on 18F-FDG PET and PET/CT imaging of head and neck cancer.

  14. Utilization of head CT during injury visits to United States emergency departments: 2012-2015.

    Science.gov (United States)

    Yun, Brian J; Borczuk, Pierre; Zachrison, Kori S; Goldstein, Joshua N; Berlyand, Yosef; Raja, Ali S

    2018-05-18

    Studies have shown increasing utilization of head computed tomography (CT) imaging of emergency department (ED) patients presenting with an injury-related visit. Multiple initiatives, including the Choosing Wisely™ campaign and evidence-based clinical decision support based on validated decision rules, have targeted head CT use in patients with injuries. Therefore, we investigated national trends in the use of head CT during injury-related ED visits from 2012 to 2015. This was a secondary analysis of data from the annual United States (U.S.) National Hospital Ambulatory Medical Care Survey from 2012 to 2015. The study population was defined as injury-related ED visits, and we sought to determine the percentage in which a head CT was ordered and, secondarily, to determine both the diagnostic yield of clinically significant intracranial findings and hospital characteristics associated with increased head CT utilization. Between 2012 and 2015, 12.25% (95% confidence interval [CI] 11.48-13.02%) of injury-related visits received at least one head CT. Overall head CT utilization showed an increased trend during the study period (2012: 11.7%, 2015: 13.23%, p = 0.09), but the results were not statistically significant. The diagnostic yield of head CT for a significant intracranial injury over the period of four years was 7.4% (9.68% in 2012 vs. 7.67% in 2015, p = 0.23). Head CT use along with diagnostic yield has remained stable from 2012 to 2015 among patients presenting to the ED for an injury-related visit. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A new method of CT scanning for the diagnosis of mandibular fractures; A preliminary report: diagnosis of condyle fractures

    Energy Technology Data Exchange (ETDEWEB)

    Tsukagoshi, Taku; Satoh, Kaneshige; Onizuka, Takuya (Showa Univ., Tokyo (Japan). School of Medicine)

    1990-08-01

    The condylar neck of the mandible is one of the most common fracture sites in the facial skeleton. Such a fracture is routinely diagnosed by A-P, lateral oblique, and Towne projection roentgenography or orthopantomography. Despite the combination of these films, fracture of the neck of the mandible is still difficult to diagnose definitely. Therefore, a new CT scanning method was developed for diagnosing fractures of the neck of the condylar mandible. The CT axis is projected along the length of the mandible, extending from the condyle to the symphysis. This projection visualizes both the condyle and the mandibular symphysis in the same plane. The patient is placed in a supine position with the head fully extended. The base line, a line extending from the midpoint of the glenoid fossa to the menton, is determined with a lateral facial cephalogram. CT scanning with a 5 mm window is performed in parallel with and 2 cm anterior to and 2 cm posterior to the base line. When CT scanning was performed in a healthy volunteer, the condition of the condyle and the condylar neck of the mandible was clearly shown, and the view extended from the condyle to the symphysis. For automobile accident patients in whom fracture of the neck of the mandible was associated with fracture of the symphysis, two fractures were found in the same plane. A newly developed CT scanning technique is useful in the diagnosis of fractures of the condylar neck of the mandible and in the identification of fractures at other mandibular sites. It also allows scanning of patients in a supine position, which may aid in managing patients with multiple traumas. (N.K.).

  16. Serial CT scans and MRI scans of Tay-Sachs disease

    International Nuclear Information System (INIS)

    Shimoizumi, Hideo; Miyao, Masutomo; Ichihashi, Koh; Sawa, Rituko; Yamamoto, Yoshifumi; Tanaka, Osamu; Yanagisawa, Masayoshi; Kamoshita, Shigehiko.

    1986-01-01

    Serial X-ray CT and MRI were performed on 2 cases of Tay-Sachs disease. Case 1 : a 3-year-10-month-old girl. Her developmental milestones were normal until the age of 6 months. At the age of 10 months, hypotonia and unduly sensitiveness to sounds were noticed. She had cherry red spots in both fundi, and the serum hexosaminidase A activity was low. Significant clinical features during the next 3 years included regression of developmental milestones to the level of one month, and myoclonic and generalised seizures. After 3 years she showed megalencephaly, unstable body temperature, and respiratory disorders. Case 2 : a 2-year-6-month-old boy. His developmental milestones were normal until the age of 5 months. Then he manifested hyperreaction to noises and further developments ceased. He started to deteriorate from the age of 1 year and 2 months, and had no head control at the age of 1 year and 6 months. Cherry red spots were detected and the serum hexsosaminidase A activity was low, too. X-ray CT at the early stage of cases 1 and 2 showed mild cerebral atrophy and high density areas in bilateral thalami and basal ganglia. At the late stage of Case 1, high density areas appeared in occipital and frontal white matters. MRI in both patients were strikingly similar. In their grey matters, linear light areas were demonstrated on IR images. Their white matters showed extensive dark (long T 1 ) areas on IR images, and extensive light (long T 2 ) areas on SE images. Bilateral thalami and basal ganglia were light on IR images and dark on SE images. The findings of MRI in our patients seemed to correlate well with pathological and biochemical changes in their brains. (author)

  17. Automated lung volumetry from routine thoracic CT scans: how reliable is the result?

    Science.gov (United States)

    Haas, Matthias; Hamm, Bernd; Niehues, Stefan M

    2014-05-01

    Today, lung volumes can be easily calculated from chest computed tomography (CT) scans. Modern postprocessing workstations allow automated volume measurement of data sets acquired. However, there are challenges in the use of lung volume as an indicator of pulmonary disease when it is obtained from routine CT. Intra-individual variation and methodologic aspects have to be considered. Our goal was to assess the reliability of volumetric measurements in routine CT lung scans. Forty adult cancer patients whose lungs were unaffected by the disease underwent routine chest CT scans in 3-month intervals, resulting in a total number of 302 chest CT scans. Lung volume was calculated by automatic volumetry software. On average of 7.2 CT scans were successfully evaluable per patient (range 2-15). Intra-individual changes were assessed. In the set of patients investigated, lung volume was approximately normally distributed, with a mean of 5283 cm(3) (standard deviation = 947 cm(3), skewness = -0.34, and curtosis = 0.16). Between different scans in one and the same patient the median intra-individual standard deviation in lung volume was 853 cm(3) (16% of the mean lung volume). Automatic lung segmentation of routine chest CT scans allows a technically stable estimation of lung volume. However, substantial intra-individual variations have to be considered. A median intra-individual deviation of 16% in lung volume between different routine scans was found. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  18. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  19. Volumetric visualization of head and neck CT data for treatment planning

    International Nuclear Information System (INIS)

    Lee, Jean S.; Jani, Ashesh B.; Pelizzari, Charles A.; Haraf, Daniel J.; Vokes, Everett E.; Weichselbaum, Ralph R.; Chen, George T.Y.

    1999-01-01

    Purpose: To demonstrate the utility of volume rendering, an alternative visualization technique to surface rendering, in the practice of CT based radiotherapy planning for the head and neck. Methods and Materials: Rendo-avs, a volume visualization tool developed at the University of Chicago, was used to volume render head and neck CT scans from two cases. Rendo-avs is a volume rendering tool operating within the graphical user interface environment of AVS (Application Visualization System). Users adjust the opacity of various tissues by defining the opacity transfer function (OTF), a function which preclassifies voxels by opacity prior to rendering. By defining the opacity map (OTF), the user selectively enhances and suppresses structures of various intensity. Additional graphics tools are available within the AVS network, allowing for the manipulation of perspective, field of view, data orientation. Users may draw directly on volume rendered images, create a partial surface, and thereby correlate objects in the 3D scene to points on original axial slices. Information in volume rendered images is mapped into the original CT slices via a Z buffer, which contains the depth information (Z coordinate) for each pixel in the rendered view. Locally developed software was used to project conventionally designed GTV contours onto volume rendered images. Results: The lymph nodes, salivary glands, vessels, and airway are visualized in detail without prior manual segmentation. Volume rendering can be used to explore the finer anatomic structures that appear on consecutive axial slices as 'points'. Rendo-avs allowed for acceptable interactivity, with a processing time of approximately 5 seconds per 256 x 256 pixel output image. Conclusions: Volume rendering is a useful alternative to surface rendering, offering high-quality visualization, 3D anatomic delineation, and time savings to the user, due to the elimination of manual segmentation as a preprocessing step. Volume rendered

  20. Spinal CT scan, 2. Lumbar and sacral spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ., Aichi (Japan))

    1982-08-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival.

  1. Role of Postmortem Multislice Computed Tomography Scan in Close Blunt Head Injury

    Directory of Open Access Journals (Sweden)

    Prijo Sidipratomo

    2014-08-01

    Full Text Available BACKGROUND: Conventional autopsy in Indonesia is not well accepted as it is contrary to religion and culture. New radiological imaging method such as multislice computed tomography (MSCT scan has potential to be a diagnostic tool in forensic pathology. The purpose of this study is to determine the ability of MSCT scan in finding abnormalities in close blunt head injury compared with autopsy. METHODS: This study used descriptive qualitative method. Postmortem cases in Department of Forensic Medicine and Radiology of Dr. Cipto Mangunkusumo Hospital were selected based on inclusion criteria. Then MSCT scan and autopsy were conducted. MSCT scan and autopsy results were compared and analyzed. RESULTS: There were 491 postmortem cases of blunt head injury. However, only 10 cases fulfilled inclusion criteria. Subarachnoid haemorrhages were identified 100% with MSCT scan and 80% with autopsy. Cerebral oedemas were identified 100% either with MSCT scan and autopsy. Subdural haemorrhages were identified 100% with MSCT scan, while 50% with autopsy. Multiple fractures were identified 80% with MSCT scan, while 40% with auto. CONCLUSIONS: MSCT scan showed a sensitive detection in finding abnormalities in close blunt head injury. Therefore it could be as an alternative choice of examination in close blunt head injury cases. KEYWORDS: multislice computed tomography scan, postmortem, blunt head injury, autopsy.

  2. Reduction of Cone-Beam CT scan time without compromising the accuracy of the image registration in IGRT

    International Nuclear Information System (INIS)

    Westberg, Jonas; Jensen, Henrik R.; Bertelsen, Anders; Brink, Carsten

    2010-01-01

    Background. In modern radiotherapy accelerators are equipped with 3D cone-beam CT (CBCT) which is used to verify patient position before treatment. The verification is based on an image registration between the CBCT acquired just before treatment and the CT scan made for the treatment planning. The purpose of this study is to minimise the scan time of the CBCT without compromising the accuracy of the image registration in IGRT. Material and methods. Fast scans were simulated by reducing the number of acquired projection images, i.e. new reconstructions based on a subset of the original projections were made. The deviation between the registrations of these new reconstructions and the original registration was measured as function of the amount of reduction. Results and Discussion. Twenty nine head and neck (HandN) and 11 stereotactic lung patients were included in the study. The mean of the registration deviation did not differ significantly from zero independently of the number of projections included in the reconstruction. Except for the smallest subset of reconstructions (10% and 25% of the original projection for the lung and HandN patients, respectively) the standard deviation of the registration differences was constant. The standard deviations were approximately 0.1 mm and 0.2 mm for the HandN and lung group, respectively. Based on these results an in-house developed solution, able to reduce the Cone-Beam CT scan time, has been implemented clinically

  3. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  4. RADIODIAGNOSIS OF PLEURAL LESIONS WITH USG AND CT SCAN

    Directory of Open Access Journals (Sweden)

    Bheemashanker

    2017-09-01

    Full Text Available BACKGROUND Ultrasound is easy available, less expensive study. It differentiates pleural effusion, consolidation and masses. CT scores in diagnosing early pleural lesions and helps in localising lesions differentiating benign and malignant. The aim of the study is to- 1. Assess the value of ultrasonography and computed tomography in evaluation of pleural lesions. 2. Determine the sensitivity and specificity of ultrasound and CT in pleural lesions. MATERIALS AND METHODS The present study was aimed at assessing the value of ultrasonography and CT in evaluating the pleural lesions. In our study, during the period of 12 months, 100 patients with pleural effusions were evaluated. The most common cause was transudate. Exudates consist of malignant and non-malignant causes. RESULTS The study group was defined into two groups- Malignant and non-malignant group based on pleural effusion of transudate and exudate types. CT and ultrasound has success rate of 100% and 85% respectively to identify neoplastic and non-neoplastic disease. Diagnostic accuracy of CT and ultrasound are comparable while CT scores over ultrasound in failed cases. CT has 100% sensitivity and 100% specificity in pleural lesions. CT has more therapeutic value compared to ultrasound. CONCLUSION The role of ultrasound and CT are complimentary, give high yield of positive results for pleural mass differentiation; useful for guided procedures like pleural biopsy and pleural drainage. Combined study not only useful for localisation of lesion, but also gives information about the extent of disease and characterising the tissue density by analysis of attenuation coefficient.

  5. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  6. Fourier-based reconstruction via alternating direction total variation minimization in linear scan CT

    International Nuclear Information System (INIS)

    Cai, Ailong; Wang, Linyuan; Yan, Bin; Zhang, Hanming; Li, Lei; Xi, Xiaoqi; Li, Jianxin

    2015-01-01

    In this study, we consider a novel form of computed tomography (CT), that is, linear scan CT (LCT), which applies a straight line trajectory. Furthermore, an iterative algorithm is proposed for pseudo-polar Fourier reconstruction through total variation minimization (PPF-TVM). Considering that the sampled Fourier data are distributed in pseudo-polar coordinates, the reconstruction model minimizes the TV of the image subject to the constraint that the estimated 2D Fourier data for the image are consistent with the 1D Fourier transform of the projection data. PPF-TVM employs the alternating direction method (ADM) to develop a robust and efficient iteration scheme, which ensures stable convergence provided that appropriate parameter values are given. In the ADM scheme, PPF-TVM applies the pseudo-polar fast Fourier transform and its adjoint to iterate back and forth between the image and frequency domains. Thus, there is no interpolation in the Fourier domain, which makes the algorithm both fast and accurate. PPF-TVM is particularly useful for limited angle reconstruction in LCT and it appears to be robust against artifacts. The PPF-TVM algorithm was tested with the FORBILD head phantom and real data in comparisons with state-of-the-art algorithms. Simulation studies and real data verification suggest that PPF-TVM can reconstruct higher accuracy images with lower time consumption

  7. The use of CT scan in the pre-operative staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Pada, C.C.

    1992-01-01

    Surgery remains the treatment of choice in patients with localized bronchogenic carcinoma. Pre-operative identification of inoperability spares the patient from unnecessary surgery. This prospective study was carried out to determine the correctness of judgement regarding a patient's operability or inoperability based on the pre-operative staging of CT scan; to find out the sensitivity, specificity and overall accuracy of the CT scan in estimating tumor description, nodal status and metastatic spread to the chest. Staging was done by 3 senior radiologists aware of the diagnosis. Both the surgical and histopathologic findings and staging were gathered and used as measurement of truth in arriving at the CT scan's accuracy. Overall accuracy rate of CT scan in determining operability or inoperability is 80%; tumor description accuracy of assessment is 87% and nodal status estimation has an accuracy of 60%. Sensitivity of CT scan is assessment of metastatic spread to the chest is 93%. There is no statistically significant difference in the judgement of operability or interpretability by CT scan compared to surgical and histopathologic results. The CT scan is recommended as a valuable tool in the pre-operative staging of patients with bronchogenic carcinoma who are candidates for surgery. (auth.). 21 refs.; 8 tabs

  8. CT scanning in stroke patients: meeting the challenge in the remote and rural district general hospital.

    Science.gov (United States)

    Todd, A W; Anderson, E M

    2009-05-01

    National audit data allow crude comparison between centres and indicate that most Scottish hospitals fail to meet current guidelines for CT scanning of the brain in stroke patients. This study identifies some of the reasons for delay in performing CT scans in a largely rural population. This audit study assesses the delays from onset of symptoms, time of admission and request received to CT scan in stroke patients for three different in-patient groups as well as those managed in the community. The reasons for delay in CT scanning varied between different patient groups but for one group of in-patients, changes in booking procedure and introduction of a second CT scanner increased the proportion scanned within 48 hours of request from 65% to 96%. Further developments including the introduction of Saturday and Sunday routine CT scanning, radiologist reporting from home and additional CT scanners placed in remote hospitals may be expected to improve these figures further. Target times of three hours from onset of symptoms to scan to allow thrombolysis may however be impossible to meet for all stroke patients in rural areas.

  9. Volumetric quantification of brain volume in children using sequential CT scans

    International Nuclear Information System (INIS)

    Hamano, K.; Iwasaki, N.; Kawashima, K.; Takita, H.

    1990-01-01

    We devised a three dimensional method for the accurate measurement of brain volume and applied it to 32 neurologically normal children, 7 children with only mental retardation and 15 children with both mental retardation and motor disturbance. In the group of neurologically normal children, the total brain volume increased from 723 cm 3 to 1407 cm 3 in order of age. The correlation ratio between the total brain volume and age was significant (P 00600.0001). The values of the total brain volume and the developmental curve were similar to those of the total brain weight of normal children previously reported. The combined volume of the cerebellum, the midbrain, the pons, and the medulla also increased from 76 cm 3 to 200 cm 3 in a manner similar to that of the total brain. The correlation between total brain volume and head circumference was significant (P<0.0001). In the group of children with mental retardation, the total brain volume was relatively smaller than that of neurologically normal children. In the group of the children with mental retardation and motor disturbance, 10 out of 15 cases showed values below -2 SD of those of neurologically normal children. The values of the total brain volume were each less than -3 SD in 3 cases whose head circumferences were each more than -3 SD. Our method for the direct measurement of brain volume based on serial CT scans may be useful for the accurate examination of brain development. (orig.)

  10. Direct sagittal CT scanning in the diagnosis of pituitary fossa tumours and posterior fossa pathology

    International Nuclear Information System (INIS)

    Podlas, H.

    1981-01-01

    Two independent methods are presented for multidirectional CT scanning of the brain using the Philips Tomoscan 300. The advantages in scanning pituitary fossa tumours and pathology of the posterior fossa are discussed. No additional software or modifications are required. Direct sagittal scanning is particularly advantageous for accurate assessment of the size of pituitary tumours and intrasellar lesions requiring surgical intervention or radiation therapy. (Auth.)

  11. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  12. Diagnostic value of CT scanning in neuromuscular diseases

    International Nuclear Information System (INIS)

    Bulcke, J.A.L.; Leuven Univ.; Herpels, V.

    1983-01-01

    The diagnosis of myopathies has become easier since the CT technique is available. In this article the possibilities of CT for diagnostic procedures of neuromuscular diseases are pointed out. Density measurements increase differentiation of atrophy or hypertrophy of muscles as well as other pathological changes. (orig.)

  13. CT scanning may adversely influence choice of surgery in paediatric ...

    African Journals Online (AJOL)

    Kurt

    with a thyroid mass. Computed tomography (CT) revealed a lesion, missed by ultrasonography, which reversed the decision to perform con- servative thyroid surgery. The lesion proved to be non-neoplastic. CT may be a useful adjunct when ultrasound demonstrates a solitary lesion and conservative surgery is considered,.

  14. Brain tumors and CT scan in infants and children, (1). The impact on pediatric neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Ohi, S; Velasco, J M [Northwestern Univ., Chicago, IL (USA). Medical School

    1980-10-01

    The dramatic change in the neuroradiological procedures have been noted after CT scan was introduced in the last several years. Remarkable decreasing numbers of angiographic, pneumoencephalographic and other invasive neuroradiologic studies as well as nuclear brain scan were also found in the pediatric neuroradiology. The authors analyzed the total numbers of these studies performed in the last several years in pediatric neurological/neurosurgical practice in the light of the impact of CT scan especially in the diagnostic procedures and treatments of brain tumor in children. Although the number of these procedures decreased up to 49% in plain skull X-ray, 54% in cerebral angiography, 70% in pneumoencephalography/ventriculography and 79% in nuclear brain scan after CT scan was installed in our results, it is extremely important to renew understanding of those characteristics in each special procedures. Cerebral angiography as well as pneumoencephalography may give the surgeon more precise ideas of the anatomical relationship between the lesion and other normal structures, especially in the posterior fossa tumor in which CT scan occassionally demonstrates only a gross finding. A case with false negative result and another case with a complicated anatomical structure in CT scan were presented. The significance of cerebral angiography and other invasive studies in the diagnosis and follow up of brain tumor in CT scan were discussed.

  15. [Non-operation management of 12 cases with brain abscess demonstrated by CT scan].

    Science.gov (United States)

    Long, J

    1990-12-01

    This paper reported 12 cases with brain abscess demonstrated by CT scan. Using antibiotic management without surgical intervention, in 10 cases the curative effects were satisfactory. The paper indicated that CT scan was very useful in prompt and correct diagnosis of brain abscess and with sequential CT scan medical therapy was feasible. It is significant in treatment of brain abscess especially for the patients who have a poor general condition, have the brain abscess located in important functional area or have multiple abscesses so that the operation is difficult for them.

  16. The Beatles, the Nobel Prize, and CT scanning of the chest.

    Science.gov (United States)

    Goodman, Lawrence R

    2010-01-01

    From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.

  17. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  18. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  19. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    International Nuclear Information System (INIS)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon

    2017-01-01

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery

  20. Value of the post-operative CT in predicting delayed flap failures following head and neck cancer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bitna; Yoon, Dae Young; Seo, Young Lan; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo; Chung, Chul Hoon [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    To identify post-operative computed tomography (CT) findings associated with delayed flap failures following head and neck cancer surgery. We retrospectively reviewed 60 patients who underwent flap reconstruction after head and neck cancer surgery and post-operative (3–14 days) contrast-enhanced CT scans for suspected complications. Patients were divided into two groups: delayed flap failure patients (patients required flap revision) (n = 18) and flap success patients (n = 42). Clinical data (age, sex, T-stage, type of flap, and time interval between reconstruction surgery and CT) and post-operative CT findings of flap status (maximum dimension of the flap, intra- or peri-flap fluid collection and intra- or peri-flap air collection, fat infiltration within the flap, fistula to adjacent aerodigestive tract or skin, and enhanced vascular pedicle) were assessed and compared between the two groups. CT findings showed that the following flap anomalies were observed more frequently in the delayed flap failure group than in the flap success group: intra- or peri-flap fluid collection > 4 cm (61.1% vs. 23.8%, p < 0.05), intra- or peri-flap air collection > 2 cm (61.1% vs. 2.4%, p < 0.001), and fistula to adjacent aerodigestive tract or skin (44.4% vs. 0%, p < 0.001). The maximum dimension of the flap, fat infiltration within the flap, and enhanced vascular pedicle were not associated with delayed flap failures. A large amount of fluid or air collection and fistula are the CT findings that were associated with delayed flap failures in patients with suspected post-operative complications after head and neck cancer surgery.

  1. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    Science.gov (United States)

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  2. Increased inspiratory pressure for reduction of atelectasis in children anesthetized for CT scan

    International Nuclear Information System (INIS)

    Sargent, Michael A.; Jamieson, Douglas H.; McEachern, Anita M.; Blackstock, Derek

    2002-01-01

    Background: Atelectasis is more frequent and more severe in children anesthetized for CT scan than it is in children sedated for CT scan.Objective: To determine the effect of increased inspiratory pressure on atelectasis during chest CT in anesthetized children. Materials and methods: Atelectasis on chest CT was assessed by two observers in three groups of patients. Group A comprised 13 children (26 lungs) anesthetized at inspiratory pressures up to and including 25 cm H 2 O. Group B included 11 children anesthetized at inspiratory pressures ≥30 cm H 2 O. Group C included 8 children under deep sedation. Results: Atelectasis was significantly more severe in group A than in groups B and C. There was no significant difference between groups B and C. Conclusion: An inspiratory pressure of 30 cm H 2 O is recommended for children anesthetized for CT scan of the chest. (orig.)

  3. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  4. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  5. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    International Nuclear Information System (INIS)

    Verhaart, René F.; Paulides, Margarethus M.; Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F.; Verduijn, Gerda M.; Lugt, Aad van der

    2014-01-01

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI db ). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T max ) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI db . Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient

  6. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Verhaart, René F., E-mail: r.f.verhaart@erasmusmc.nl; Paulides, Margarethus M. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F. [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands); Verduijn, Gerda M. [Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Lugt, Aad van der [Department of Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands)

    2014-12-15

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI{sub db}). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T{sub max}) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI{sub db}. Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm

  7. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: a comparison of CT and CT-MRI based tissue segmentation on simulated temperature.

    Science.gov (United States)

    Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van der Lugt, Aad; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M

    2014-12-01

    In current clinical practice, head and neck (H&N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors' study is to investigate the relevance of using MRI in addition to CT for patient modeling in H&N HTP. CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H&N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRIdb). To quantify the relevance of MRI based segmentation for H&N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (Tmax) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRIdb. In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient models based on CT (Tmax: 38.0 °C) and CT and MRI

  8. Variations of patient dose in CT scan of skull using a female phantom

    International Nuclear Information System (INIS)

    Estanislau, Bruno A.; Mourao, Arnaldo P.

    2013-01-01

    This paper presents a comparison between the doses deposited in organs in CT scans of the skull when using different protocols in operating the TC unit. The protocols differ in the currents and voltages of the X-ray tube

  9. Analysis the findings of chest radiograph and CT scan in 217 acute thoracic trauma

    International Nuclear Information System (INIS)

    Huang Shaoying

    2005-01-01

    Objective: To evaluate chest radiograph and CT scan in assessing acute thoracic trauma. Methods: Retrospectively analyzed the findings of chest radiograph and CT scan in 217 cases of acute thoracic trauma and positive rate of each modality was compared. Results: The positive rate of rib and clavicle fracture was higher in chest radiograph than these in CT scan. But the positive rate of chest wall hematoma, mediastinum and subcutaneous emphysema, pneumothorax, hydropneumothorax, damage of lung parenchyma and traumatic pulmonary atelectasis was higher in CT scan than those in chest radiograph. Conclusion: The application of the combined imaging modalities improves assessing of acute thoracic trauma, because the imaging manifestation of the lesion is various. (authors)

  10. Socio-economic variation in CT scanning in Northern England, 1990-2002

    Directory of Open Access Journals (Sweden)

    Pearce Mark S

    2012-01-01

    Full Text Available Abstract Background Socio-economic status is known to influence health throughout life. In childhood, studies have shown increased injury rates in more deprived settings. Socio-economic status may therefore be related to rates of certain medical procedures, such as computed tomography (CT scans. This study aimed to assess socio-economic variation among young people having CT scans in Northern England between 1990 and 2002 inclusive. Methods Electronic data were obtained from Radiology Information Systems of all nine National Health Service hospital Trusts in the region. CT scan data, including sex, date of scan, age at scan, number and type of scans were assessed in relation to quintiles of Townsend deprivation scores, obtained from linkage of postcodes with census data, using χ2 tests and Spearman rank correlations. Results During the study period, 39,676 scans were recorded on 21,089 patients, with 38,007 scans and 19,485 patients (11344 male and 8132 female linkable to Townsend scores. The overall distributions of both scans and patients by quintile of Townsend deprivation scores were significantly different to the distributions of Townsend scores from the census wards included in the study (p Conclusions Social inequalities exist in the numbers of young people undergoing CT scans with those from deprived areas more likely to do so. This may reflect the rates of injuries in these individuals and implies that certain groups within the population may receive higher radiation doses than others due to medical procedures.

  11. Utility of whole-body (head-to-toe) PET/CT in the evaluation of melanoma and sarcoma patients.

    Science.gov (United States)

    Webb, Heather R; Latifi, Hamid R; Griffeth, Landis K

    2018-01-01

    The aim of this study was to assess the added benefit of whole-body (head-to-toes) PET/CT versus routine 'eyes-to-thighs' PET/CT of melanoma and sarcoma patients. We performed a retrospective review of consecutive whole-body PET/CT scans from January 2006 through December 2010 in patients with melanoma or sarcoma. PET abnormalities in the brain, distal thighs, and legs were recorded and clinical significance was assessed on the basis of pathology, imaging studies, and clinical follow-up. Patients with known primary lesions distal to the proximal femora were excluded as these patients would routinely undergo 'head-to-toe' PET/CT. We reviewed reports from 352 PET/CT examinations in 194 patients with melanoma and 75 PET/CT examinations in 44 patients with sarcoma. Melanoma: 13 patients had brain metastases on PET. In five of these patients, lesions were unknown, but all were in the setting of other metastatic disease. Twenty-seven patients had lower extremity metastases, all in the setting of other metastatic disease. No lower extremity metastases were found in the remaining 167 patients. Sarcoma: one patient had an isolated, unexpected brain metastasis. Six patients had leg metastases, but none were isolated. No lower extremity metastases were found in the remaining 38 patients. In patients with melanoma and sarcoma, inclusion of entire lower extremities adds little additional clinical value as detection of isolated, unexpected metastasis is rare. Brain imaging may add value as the presence of brain metastases alters clinical management. Overall, in patients with melanoma or sarcoma, whole-brain PET/CT imaging may be of value, but routine inclusion of the entire lower extremities adds little additional value.

  12. Lymphoma no Hodgkin extra nodal in head and neck: value of CT

    International Nuclear Information System (INIS)

    Ramos Aguilar, A.; Romance Garcia, A.; Fuentes Lupianez, J.J.; Sanchez Lafuente, J.; Rodriguez Sanpedro, F.

    1994-01-01

    The head and neck regions is one of the most common sites of extra nodal non-Hodgkin's lymphoma (NHL). We studied 7 cases of NHL of head and neck using CT enhanced with intravenous contrast medium, analyzing the important role it plays in diagnosis, treatment planning and evaluation of the recurrence of these tumors. (Author)

  13. A case of severe acute pancreatitis with near total pancreatic necrosis diagnosed by dynamic CT scanning

    International Nuclear Information System (INIS)

    Takeda, Kazunori; Kakugawa, Yoichiro; Amikura, Katsumi; Miyagawa, Kikuo; Matsuno, Seiki; Sato, Toshio

    1987-01-01

    A 42 year-old woman with severe acute pancreatitis had drainage of the pancreatic bed, cholecystostomy and jejunostomy on admission, but symptoms were not improved. Fourteen days after admission, clinical sepsis and septisemia were recognized. Dynamic CT scanning of the pancreas showed near total pancreatic necrosis. Symptoms were improved after necrosectomy of the pancreas and debridement of the peripancreatic necrotic tissue were performed. Our experience suggests the usefulness of dynamic CT scanning for detection of pancreatic necrosis in severe acute pancreatitis. (author)

  14. Hybrid imaging with contrast enhanced CT scan: A nuclear physician's point of view

    International Nuclear Information System (INIS)

    Houzard, C.; Tychyj-Pinel, C.; Defez, D.; Valette, P.J.; Giammarile, F.; Houzard, C.; Valette, P.J.; Giammarile, F.

    2010-01-01

    The ongoing development of hybrid imaging, with physical association of CT scan and PET or SPECT scan, allows integrating morphological and functional information on a single exam. This important technological evolution changes diagnostic and therapeutic strategy in a major manner, essentially in oncology. The possibility to inject intravenously iodinated contrast media in order to enhance CT image contrast is still a controversial question in France. We present our experience in this domain by approaching technical problems and diagnostic advantages. (authors)

  15. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  16. F-18-Fluorodeoxyglucose Positron Emission Tomography/CT Scanning in Diagnosing Vascular Prosthetic Graft Infection

    NARCIS (Netherlands)

    Saleem, Ben R.; Pol, Robert A.; Slart, Riemer H. J. A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2014-01-01

    Vascular prosthetic graft infection (VPGI) is a severe complication after vascular surgery. CT-scan is considered the diagnostic tool of choice in advanced VPGI. The incidence of a false-negative result using CT is relatively high, especially in the presence of low-grade infections.

  17. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  18. Role of computed tomography (CT scan in staging of cervical carcinoma

    Directory of Open Access Journals (Sweden)

    T V Prasad

    2014-01-01

    Full Text Available Background & objectives: Staging of cervical carcinoma is done clinically using International Federation of Obstetrics and Gynecology (FIGO guidelines. It is based on physical examination findings and also includes results of biopsy, endoscopy and conventional radiological tests like chest radiograph, intravenous urography and barium enema. These conventional radiological investigations have largely been replaced by computed tomography (CT and magnetic resonance imaging (MRI at present. FIGO staging system does not consider CT and MRI mandatory; however, use of these modalities are encouraged. This prospective study was conducted to determine the role of CT in staging work up in women diagnosed with cervical carcinoma. Methods: Fifty three women diagnosed with cervical carcinoma were evaluated with contrast enhanced CT scan of abdomen and pelvis. CT scan images were especially evaluated to determine tumour size, invasion of parmetrium, pelvic walls, rectum, urinary bladder and ureters, pelvic or retroperitoneal lymphadenopathy and distant metastases. CT findings were associated with clinical findings and staging, including findings from cystoscopy and sigmoidoscopy. Results: There was a poor agreement between clinical and CT staging of cervical carcinoma. Primary tumour was demonstrated on CT in 36 (70% of 53 patients. CT underestimated the parametrial, vaginal and pelvic wall invasion when compared with physical examination. CT overestimated the urinary bladder and rectal invasion when compared with cysto-sigmoidoscopy, however, CT had 100 per cent negative predictive value (NPV to exclude bladder and rectal involvement. CT detection of lymph node enlargement and lung metastases influenced the management. Interpretation & conclusions: Our findings show that CT scan does not reliably correlate with clinical FIGO staging of cervical cancer. However, it can detect urinary obstruction as well as nodal or distant metastases and thus improves the

  19. Experimental validation of a newly designed 6 degrees of freedom scanning laser head: Application to three-dimensional beam structure

    International Nuclear Information System (INIS)

    Di Maio, D.; Copertaro, E.

    2013-01-01

    A new scanning laser head is designed to use single Laser Doppler Vibrometer (LDV) for performing measurements up to 6 degrees of freedom (DOF) at a target. The scanning head is supported by a rotating hollow shaft, which allows the laser beam to travel up to the scanning head from an opposite direction where an LDV is set up. The scanning head is made of a set of two mirrors, which deflects the laser beam with an angle so that the rotation of the scanning head produces a conical scan. When measurements are performed at the focal point of the conical scan then three translational vibration components can be measured, otherwise the very small circle scan, before and after the focal point, can measure up to 6 degrees of freedom, including three translations and three rotations. This paper presents the 6DOF scanning head and the measurements of 3D operational deflection shapes of a test structure

  20. Brain CT scan in acute carbon monoxide poisoning

    International Nuclear Information System (INIS)

    We, En-Huei

    1986-01-01

    The brain CT findings in 19 patients with acute carbon monoxide poisoning was analysed and the emphasis was placed on the relationship between CT findings and prognosis. Five had a normal manifestation in CT ; eight had the findings of ovoid or patchy low density area in globus pallidus, bilateral or unlateral, during the second day to fifth week after poisoning, and the low density areas were decreasing and blurring in edge in follow up and at last disappeared during 3 - 14 weeks in three cases of them ; nine showed the appearance of diffuse low density of white matter and of globus pallidus in some of them ; two had an appearance of brain atrophy. The pathology of CT findings mentioned above may be brain edema, necrosis, malacia and degeneration in gray matter and globus pallidus. The result suggested the cases with normal CT manifestation, cerebral edema and decreasing and disappearing low density area had a good prognosis, in contrary, the cases with persistant low density in globus pallidus had a poorer prognosis. (author)

  1. Advantage of CT scan in muscular pathology. Personal cases and review of the literature

    International Nuclear Information System (INIS)

    Laroche, M.; Rousseau, H.; Mazieres, B.; Bonafe, A.; Joffre, F.; Arlet, J.

    1989-01-01

    The advantage of CT scans in muscular pathology is studied. The scan, in addition to the diagnosis of tumors and muscular abscesses, permits to differentiate primary myopathies from neurogenic atrophies: in the course of myopathies, the muscle volume is preserved and they appear as a hypodensity; in neurogenic atrophies, the muscle volume is reduced with preserved density. The CT scan permits to determine the extension of these lesions. In the course of polymyositis, certain forms of rheumatid arthritis, the scan discloses a trabecular and 'worm-eaten' aspect of the muscles. This is also observed after long-term steroid therapy and other endocrine diseases (hyperthyroidism, osteomalacia) indicating an infra-clinical myopathy. In vertebral osteoporosis with fractures and patients with chronic lumbalgia, very ofter, an atrophy of the spinal muscle is observed. Finally, in the course of acquired kyphosis of the adult patient (camptocormia), the CT scan suggest an isolated myopathy, with late manifestations, of the paravertebral muscles [fr

  2. Advantage of CT scan in muscular pathology. Personal cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Laroche, M.; Rousseau, H.; Mazieres, B.; Bonafe, A.; Joffre, F.; Arlet, J.

    1989-05-01

    The advantage of CT scans in muscular pathology is studied. The scan, in addition to the diagnosis of tumors and muscular abscesses, permits to differentiate primary myopathies from neurogenic atrophies: in the course of myopathies, the muscle volume is preserved and they appear as a hypodensity; in neurogenic atrophies, the muscle volume is reduced with preserved density. The CT scan permits to determine the extension of these lesions. In the course of polymyositis, certain forms of rheumatid arthritis, the scan discloses a trabecular and 'worm-eaten' aspect of the muscles. This is also observed after long-term steroid therapy and other endocrine diseases (hyperthyroidism, osteomalacia) indicating an infra-clinical myopathy. In vertebral osteoporosis with fractures and patients with chronic lumbalgia, very ofter, an atrophy of the spinal muscle is observed. Finally, in the course of acquired kyphosis of the adult patient (camptocormia), the CT scan suggest an isolated myopathy, with late manifestations, of the paravertebral muscles.

  3. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, Adam N.; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; McKinstry, Robert C. [Barnes Jewish Hospital, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Washington University School of Medicine, St. Louis, MO (United States); Vyhmeister, Ross [Washington University School of Medicine, St. Louis, MO (United States); Ramirez-Giraldo, Juan Carlos [Siemens Healthcare, Malvern, PA (United States)

    2015-03-17

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality. (orig.)

  4. Evaluation of the use of automatic exposure control and automatic tube potential selection in low-dose cerebrospinal fluid shunt head CT.

    Science.gov (United States)

    Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C

    2015-06-01

    Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.

  5. Evaluation of diagnostic quality in musculoskeletal three-dimensional CT scans

    International Nuclear Information System (INIS)

    Vannier, M.W.; Hildebolt, C.F.; Gilula, L.A.; Sutherland, C.J.; Offutt, C.J.; Drebin, R.; Mantle, M.; Giordono, T.A.

    1988-01-01

    A major application of three-dimensional computed tomography (CT) is in the imaging of the skeleton. Three-dimensional CT has an important role in determining the presence and extent of congenital and acquired orthopedic abnormalities. The objective of this study was to compare the diagnostic sensitivity and specificity of three-dimensional CT, planar CT, and plain radiography in the detection and characterization of orthopedic abnormalities. Three-dimensional CT scan reconstructions were obtained by two methods, surface reconstruction and volumetric techniques. Seventy patients were imaged with CT, three-dimensional CT, and plain radiography. The consensus opinion of experts with access to all images plus clinical history, surgical findings, and follow-up findings were taken as truth. Expert radiologists read these cases in a blinded fashion. The results were compared using receiver operating characteristic (ROC) analysis. The diagnostic value of each three-dimensional reconstruction method and the parameters used to perform the reconstructions were evaluated

  6. A primitive study on unsupervised anomaly detection with an autoencoder in emergency head CT volumes

    Science.gov (United States)

    Sato, Daisuke; Hanaoka, Shouhei; Nomura, Yukihiro; Takenaga, Tomomi; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-02-01

    Purpose: The target disorders of emergency head CT are wide-ranging. Therefore, people working in an emergency department desire a computer-aided detection system for general disorders. In this study, we proposed an unsupervised anomaly detection method in emergency head CT using an autoencoder and evaluated the anomaly detection performance of our method in emergency head CT. Methods: We used a 3D convolutional autoencoder (3D-CAE), which contains 11 layers in the convolution block and 6 layers in the deconvolution block. In the training phase, we trained the 3D-CAE using 10,000 3D patches extracted from 50 normal cases. In the test phase, we calculated abnormalities of each voxel in 38 emergency head CT volumes (22 abnormal cases and 16 normal cases) for evaluation and evaluated the likelihood of lesion existence. Results: Our method achieved a sensitivity of 68% and a specificity of 88%, with an area under the curve of the receiver operating characteristic curve of 0.87. It shows that this method has a moderate accuracy to distinguish normal CT cases to abnormal ones. Conclusion: Our method has potentialities for anomaly detection in emergency head CT.

  7. Multi-institutional collaborating study on CT scan of schizophrenia

    International Nuclear Information System (INIS)

    Takahashi, Ryo; Sato, Tokijiro; Okuma, Teruo

    1984-01-01

    More abnormal CT findings were observed in nuclear schizophrenic patients (55%) than in the matchable controls with a statistically significant difference. According to the site of the brain, these were marked in the whole ventricle (especially the third ventricle) and in the cortex including the longitudinal fissure, frontal lobe, temporal lobe, and sylvian fissure (especially of the left hemisphere). There was no correlation between the cerebral ventricular enlargement and the patient's age, the duration of illness or drug dosage, suggesting that the enlargement may exist from the onset of the disease. Aging or taking drug(s) were also not responsible for the cortical atrophy. CT findings were associated mainly with negative symptoms. In particular, the association between abnormalities of the left hemisphere and psychiatric symptoms was marked. Direct measurements of CT images revealed significantly higher incidences only in the third ventricular enlargement in schizophrenic patients. These results suggest the possibility that subtypes of schizophrenia can be classified. (Namekawa, K.)

  8. Value of PET/CT in the approach to head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Curioni, Otavio Alberto; Amar, Ali; Viana, Debora [Hospital Heliopolis, Sao Paulo, SP (Brazil). Service of Head and Neck Surgery and Otorhynolaryngology; Souza, Ricardo Pires de [Hospital Heliopolis, Sao Paulo, SP (Brazil). Service of Radiology; Rapoport, Abrao [Hospital Heliopolis, Sao Paulo, SP (Brazil); Dedivitis, Rogerio Aparecido [Universidade de Sao Paulo (HC-FMUSP), SP (Brazil). Hospital das Clinicas. Group of Larynx and Hypopharynx; Cernea, Claudio Roberto; Brandao, Lenine Garcia [Universidade de Sao Paulo (FMUSP), SP (Brazil). Fac. de Medicina. Dept. of Head and Neck Surgery

    2012-11-15

    Objective: To evaluate the role of PET/CT in the approach to patients with head and neck cancer. Materials and Methods: Retrospective study of medical records and PET/CT images of 63 patients with head and neck cancer. Results: Alterations were observed in 76% of the cases. Out of these cases, 7 (11%) were considered as false-positive, with SUV < 5.0. PET/CT demonstrated negative results in 15 cases (24%). Among the 14 cases where the method was utilized for staging, 3 (22%) had their stages changed. Conclusion: PET/CT has shown to be of potential value in the routine evaluation of patients with head and neck cancer, but further studies of a higher number of cases are required to define a protocol for utilization of the method. (author)

  9. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  10. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  11. Investigation of CT scan frequency in children based on RIS in a hospital

    International Nuclear Information System (INIS)

    Sun Yinping; Chen Junbo; Xiao Guobing; Sun Quanfu; Niu Haowei; Fu Yinghua

    2014-01-01

    Objective: To ascertain the frequency distribution of CT examinations in children. Method: A wide range of information was collected through the radiology information system (RIS), including ID, sex, birth date, examination time, the examined part of body and other relevant ones related to children who underwent CT examinations between Jan 1, 2012 and Dec 31, 2012. The SAS software was used for data processing and statistical analysis. Results: A total of 1 542 children underwent 1 670 examinations, of which 67% were male. Head CT examination was the most frequent,accounting for 71.9% of all CT examinations, and followed by the abdomen/pelvis examinations. The number of examinations of children undergoing the repetitive examination accounted for 6.4%; 51.7% of the examinations was for trauma. The positive rate of CT examination was 51%, dependent upon the age and examined body parts to some extent. The younger patients had lower positive rate, and the positive rate of head CT examination was lower than those in other parts. Conclusions: To reduce the possible cancer risk to be induced by the ionizing radiation from CT, justification of CT examination should be considered for children. (authors)

  12. Assessment of pancreatic adenocarcinoma: use of low-dose whole pancreatic CT perfusion and individualized dual-energy CT scanning

    International Nuclear Information System (INIS)

    Li, Hai-ou; Guo, Jun; Li, Xiao; Qi, Yao-dong; Wang, Xi-ming; Xu, Zhuo-dong; Liu, Cheng; Chen, Jiu-hong

    2015-01-01

    The objective of this study was to investigate the value of low-dose whole pancreatic computed tomography (CT) perfusion integrated with individualized dual-energy CT (DECT) scanning in the diagnosis of pancreatic adenocarcinoma. Twenty patients with pancreatic adenocarcinoma underwent pancreatic CT perfusion as well as individualized dual-phase DECT pancreatic scans. Perfusion characteristics of non-tumourous pancreatic parenchyma and pancreatic adenocarcinoma were analysed. Weighted-average 120 kVp images and the optimal monoenergetic images in dual phase were reconstructed and the contrast noise ratio (CNR) of pancreas-to-tumour were compared. There were significant difference on blood flow as well as blood volume between pancreatic adenocarcinoma and the non-tumourous pancreatic parenchyma (P < 0.05), whereas no difference on permeability (P > 0.05). CNRs of pancreas-to-tumour in individualized pancreatic phase were significantly higher than those in venous phase (P < 0.05), and CNRs of optimal monoenergetic images were higher than those on weighted-average 120 kVp images (P < 0.05) in both phase. Total effective radiation dose of CT examination was around 9.32–13.75 mSv. Low-dose whole pancreatic CT perfusion can provide functional information, and the individualized pancreatic phase DECT scan is the optimal method for detecting pancreatic adenocarcinomas. The integration of the two techniques has great value in clinical application.

  13. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  14. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  15. Automated volumetry of temporal horn of lateral ventricle for detection of Alzheimer's disease in CT scan

    Science.gov (United States)

    Takahashi, Noriyuki; Kinoshita, Toshibumi; Ohmura, Tomomi; Matsuyama, Eri; Toyoshima, Hideto

    2018-02-01

    The rapid increase in the incidence of Alzheimer's disease (AD) has become a critical issue in low and middle income countries. In general, MR imaging has become sufficiently suitable in clinical situations, while CT scan might be uncommonly used in the diagnosis of AD due to its low contrast between brain tissues. However, in those countries, CT scan, which is less costly and readily available, will be desired to become useful for the diagnosis of AD. For CT scan, the enlargement of the temporal horn of the lateral ventricle (THLV) is one of few findings for the diagnosis of AD. In this paper, we present an automated volumetry of THLV with segmentation based on Bayes' rule on CT images. In our method, first, all CT data sets are normalized into an atlas by using linear affine transformation and non-linear wrapping techniques. Next, a probability map of THLV is constructed in the normalized data. Then, THLV regions are extracted based on Bayes' rule. Finally, the volume of the THLV is evaluated. This scheme was applied to CT scans from 20 AD patients and 20 controls to evaluate the performance of the method for detecting AD. The estimated THLV volume was markedly increased in the AD group compared with the controls (P < .0001), and the area under the receiver operating characteristic curve (AUC) was 0.921. Therefore, this computerized method may have the potential to accurately detect AD on CT images.

  16. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  17. Scanning technology with multi-slice helical CT in security inspection domain

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Jiang Zenghui

    2008-01-01

    The paper analyzes the technology conditions of security inspection in home and abroad, and expatiates technology of spiral CT and how to define CT value etc, with studying on the key technology of spiral CT scanning way (X-RAY, detector, technology of pulley etc) and mutual relation. By comparing the present products of security inspection, the conclusion was drawn that it is inevitable to develop the tendency of security inspection area with the checking and discerning the substance by using the technology of multi-layer spiral CT. (authors)

  18. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  19. Colon distension and scan protocol for CT-colonography: an overview

    NARCIS (Netherlands)

    Boellaard, Thierry N.; de Haan, Margriet C.; Venema, Henk W.; Stoker, Jaap

    2013-01-01

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension,

  20. Appearance of the aging pancreas on CT scans: Implications in diagnosis of pancreatic carcinoma

    International Nuclear Information System (INIS)

    Mattison, G.R.; Francis, I.R.; Glazer, G.M.; Trenkner, S.W.

    1986-01-01

    Because early pancreatic cancer may not appear on CT as a frank mass, the CT-based diagnosis relies on detection of subtle changes such as focal loss of lobulation or asymmetry in the distribution of tissue. The author studied the normal pancreas in 140 patients of different ages to determine if there is an overlap in the appearance of the normal aging pancreas and subtle signs of pancreatic cancer. Both contour lobulation and fatty infiltration were found to increase with age and involved the pancreatic body and tail more than the head. These normal age-related changes should be recognized to avoid overdiagnosing pancreatic head masses

  1. Centre for Industrial Application of CT scanning (CIA-CT) – Four years of results 2009-2013

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Andreasen, Jan Lasson; Christensen, Lars Bager

    activities: Centre of Excellence, Dissemination, Collaboration, Research, and Initiation of new activities. The consortium has consisted of nine partners, including three research institutions, two consultancy partners, two large companies, and two small / medium enterprises. The consortium has acted......The innovation consortium project, carried out September 2009 – August 2013, has aimed to help the participating companies and Danish industry with the introduction of CT scanning as measuring technology, carrying out research at international level. The project has operated through five main...... as a centre of excellence for industrial CT scanning, both nationally and internationally. A network with approx. 40 participants has been established, and a total of 22 students have been educated. Dissemination activities have encompassed: a web page www.cia-ct.mek.dtu.dk , 8 newsletters, 4 topical...

  2. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  3. A review of patient dose and optimisation methods in adult and paediatric CT scanning

    International Nuclear Information System (INIS)

    Dougeni, E.; Faulkner, K.; Panayiotakis, G.

    2012-01-01

    Highlights: ► CT scanning frequency has grown with the development of new clinical applications. ► Up to 32-fold dose variation was observed for similar type of procedures. ► Scanning parameters should be optimised for patient size and clinical indication. ► Cancer risks knowledge amongst physicians of certain specialties was poor. ► A significant number of non-indicated CT scans could be eliminated. - Abstract: An increasing number of publications and international reports on computed tomography (CT) have addressed important issues on optimised imaging practice and patient dose. This is partially due to recent technological developments as well as to the striking rise in the number of CT scans being requested. CT imaging has extended its role to newer applications, such as cardiac CT, CT colonography, angiography and urology. The proportion of paediatric patients undergoing CT scans has also increased. The published scientific literature was reviewed to collect information regarding effective dose levels during the most common CT examinations in adults and paediatrics. Large dose variations were observed (up to 32-fold) with some individual sites exceeding the recommended dose reference levels, indicating a large potential to reduce dose. Current estimates on radiation-related cancer risks are alarming. CT doses account for about 70% of collective dose in the UK and are amongst the highest in diagnostic radiology, however the majority of physicians underestimate the risk, demonstrating a decreased level of awareness. Exposure parameters are not always adjusted appropriately to the clinical question or to patient size, especially for children. Dose reduction techniques, such as tube-current modulation, low-tube voltage protocols, prospective echocardiography-triggered coronary angiography and iterative reconstruction algorithms can substantially decrease doses. An overview of optimisation studies is provided. The justification principle is discussed along

  4. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  5. CT of multiple sclerosis: reassessment of delayed scanning with high doses of contrast material

    International Nuclear Information System (INIS)

    Spiegel, S.M.; Vinuela, F.; Fox, A.J.; Pelz, D.M.

    1985-01-01

    A prospective study involving 87 patients was carried out to evaluate the necessity for a high dose of contrast material in addition to delayed computed tomographic (CT) scanning for optimal detection of the lesions of multiple sclerosis in the brain. In patients with either clinically definite multiple sclerosis or laboratory-supported definite multiple sclerosis, CT scans were obtained with a uniform protocol. Lesions consistent with multiple sclerosis were demonstrated on the second scan in 54 patients. In 36 of these 54 patients, the high-dose delayed scan added information. These results are quite similar to those of a previous study from this institution using different patients, in whom the second scan was obtained immediately after the bolus injection of contrast material containing 40 g of organically bound iodine. The lack of real difference in the results of the two studies indicate that the increased dose, not just the delay in scanning, is necessary for a proper study

  6. Gambaran CT Scan Toraks Sesuai dengan Jenis Sitologi/Histologi pada Pasien Kanker Paru yang Merokok

    Directory of Open Access Journals (Sweden)

    Rosa Tatun

    2016-03-01

    Full Text Available Kanker paru merupakan  penyebab kematian paling banyak akibat keganasan. Kanker paru memberikan gambaran CT scan yang berbeda sesuai dengan jenis sitologi/histologinya. Pemeriksaan CT scan  toraksdengan teknik high resolution computed tomography (HRCT dapat memperlihatkan kelainan kanker parusecara rinci. Penelitian dilakukan di Instalasi Radiologi RSU Persahabatan, Jakarta bekerja sama denganDepartemen Pulmonologi dan Respirasi RSU Persahabatan terhadap 100 sampel yang diperoleh pada bulanNovember 2014 hingga Maret 2015. Berdasarkan jenis sitologi/histologi kanker paru (adenokarsinoma dankarsinoma sel skuamosa/KSS tidak ditemukan  variabel yang bermakna secara statistik  (bentuk, letak, tepispikulasi, tepi lobulasi, nodul satelit. Variabel yang paling banyak ditemukan pada adenokarsinoma maupunKSS adalah bentuk massa, lokasi di sentral dan paru sebelah kanan. Gambaran kanker paru adenokarsinomadan KSS pada pasien merokok paling banyak berupa massa, lokasi di sentral dan lobus kanan paru. Kata kunci: kanker paru, merokok, CT scan toraks   Lung Cancer CT Scan Findings in Smoker Patients Basedon Cytology/Histology Abstract Lung cancer is the leading cause of most deaths due to malignancy. Lung cancer CT scan provides an overview according to the type of cytology / histology. Thorax CT scan with high resolution technique (HRCT may revealdetail lung cancer abnormalities. This study was conducted between Department of Radiology and Departmentof Pulmonology Respiratory, Persahabatan Hospital Jakarta based on 100 samples, November 2014 until March2015. Based on cytological/histological type (adenocarcinoma and squamous cell carcinoma/KSS, it was not found significant meaningfull variables (shape, location, spiculate edge, lobulate edge, satellite nodules. Most commonly variables found in adenocarcinomas and KSS were mass forming, central location, right lung location.Most of adenocarcinoma and SCC in smoked patients were mass forming, central

  7. Body surface area determined by whole-body CT scanning: need for new formulae?

    DEFF Research Database (Denmark)

    Villa, Chiara; Primeau, Charlotte; Hesse, Ulrik

    2017-01-01

    Calculation of the estimated body surface area (BSA) by body height and weight has been a challenge in the past centuries due to lack of a well-documented gold standard. More recently, available techniques such as 3D laser surface scanning and CT scanning may be expected to quantify the BSA...... Mimics software, and BSA values were automatically extracted from the program. They were compared with nine predictive equations from the literature. Remarkably, close correlations (r > 0·90) were found between BSA values from CT scans and those from the predictive formulae. A mean BSA of the 54 cadavers...... equations, with the CT scan determination as gold standard. It is concluded that DuBois and DuBois' equation can be safely used in normal-weight male subjects with high accuracy, but it seems likely that BSA is underestimated in underweight subjects and overestimated in overweight individuals. Creation...

  8. Atlas ranking and selection for automatic segmentation of the esophagus from CT scans

    Science.gov (United States)

    Yang, Jinzhong; Haas, Benjamin; Fang, Raymond; Beadle, Beth M.; Garden, Adam S.; Liao, Zhongxing; Zhang, Lifei; Balter, Peter; Court, Laurence

    2017-12-01

    In radiation treatment planning, the esophagus is an important organ-at-risk that should be spared in patients with head and neck cancer or thoracic cancer who undergo intensity-modulated radiation therapy. However, automatic segmentation of the esophagus from CT scans is extremely challenging because of the structure’s inconsistent intensity, low contrast against the surrounding tissues, complex and variable shape and location, and random air bubbles. The goal of this study is to develop an online atlas selection approach to choose a subset of optimal atlases for multi-atlas segmentation to the delineate esophagus automatically. We performed atlas selection in two phases. In the first phase, we used the correlation coefficient of the image content in a cubic region between each atlas and the new image to evaluate their similarity and to rank the atlases in an atlas pool. A subset of atlases based on this ranking was selected, and deformable image registration was performed to generate deformed contours and deformed images in the new image space. In the second phase of atlas selection, we used Kullback-Leibler divergence to measure the similarity of local-intensity histograms between the new image and each of the deformed images, and the measurements were used to rank the previously selected atlases. Deformed contours were overlapped sequentially, from the most to the least similar, and the overlap ratio was examined. We further identified a subset of optimal atlases by analyzing the variation of the overlap ratio versus the number of atlases. The deformed contours from these optimal atlases were fused together using a modified simultaneous truth and performance level estimation algorithm to produce the final segmentation. The approach was validated with promising results using both internal data sets (21 head and neck cancer patients and 15 thoracic cancer patients) and external data sets (30 thoracic patients).

  9. Brain tumors and CT scans in infants and children, (3)

    International Nuclear Information System (INIS)

    Oi, Shizuo

    1983-01-01

    In clinical pictures of brain tumors in infants and children, many features are not identical to those in adults, including characteristics of the tumors in age population, the locations of the tumors, the clinical symptoms and signs, and various factors affecting prognosis. We have, therefore, clinically and extensively analyzed brain tumors in infants and children. This study was also performed in order to analyze the characteristic CT findings of astrocytoma, the tumor most frequently occurring among infants and children. The subjects were 24 cases of astrocytoma and 2 cases of glioblastoma in infants and children under 16 years. The locations and characteristics of the tumors were as follows. Most of the tumors occurred in the 4th ventricle, had a characteristic low density, and could almost entirely be clearly distinguished from medulloblastomas, but not from ependymomas, on CT. The features of the supratentorial tumors were similar to those of the astrocytomas and glioblastomas mostly appearing in adults, as previously reported, in the relatively close correlation with the location and malignancy of the tumor. There was also a case of diffuse astrocytoma, a ''non-enhanced low-density solid tumor,'' which raised clinical problems. Among low-grade astrocytomas in infants and children, only a few show a high density on plain CT, many have, at least macroscopically, a strong contrast enhancement, and peritumoral edema is not observed on CT or, if observed, is observed only slightly. As individual features, homogenous enhancement pattern, a mixed density, a central low density, and a rare absence of enhancement are listed. (author)

  10. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  11. CT Scans in Young People in Great Britain: Temporal and Descriptive Patterns, 1993–2002

    Directory of Open Access Journals (Sweden)

    Mark S. Pearce

    2012-01-01

    Results. The number of CT examinations doubled over the study period. While increases in numbers of recorded examinations were seen across all age groups, the greatest increases were in the older patients, most notably those aged 15–19 years of age. Sixty percent of CT examinations were of the head, with the percentages varying with calendar year and patient age. Conclusions. In contrast to previous data from the North of England, the doubling of CT use was not accompanied by an increase in numbers of multiple examinations to the same individual.

  12. CT scan findings and EEG in systemic lupus erythematodes patients with neuro-psychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Rumiko; Hagiwara, Mariko; Katayose, Keiko; Yashima, Yuko; Kumashiro, Hisashi

    1988-06-01

    In 14 patients with systemic lupus erythematodes presenting with neuro-psychiatric disorders, CT scans were compared with encephalographic (EEG) findings. CT findings were markedly abnormal in 6, slight with a sulcal enlargement in 3, and normal in 5. In the group of markedly abnormal CT findings, focal abnormal low density areas were detected in 2, severe generalized cerebral atrophy in one, and severe atrophy of the right hemisphere in one. EEG findings included focal paroxysmal abnormality of high voltage slow burst at the left frontal dominance and positive spike on the right hemisphere. Epileptic seizure and depressed sensorium seemed to be related to CT abnormality. In 3 patients with epileptic seizures, their symptoms were closely related to CT abnormality. Parkinsonisms and depressed sensorium were also related to CT abnormality. (Namekawa, K).

  13. CT scan findings and EEG in systemic lupus erythematodes patients with neuro-psychiatric disorders

    International Nuclear Information System (INIS)

    Kan, Rumiko; Hagiwara, Mariko; Katayose, Keiko; Yashima, Yuko; Kumashiro, Hisashi

    1988-01-01

    In 14 patients with systemic lupus erythematodes presenting with neuro-psychiatric disorders, CT scans were compared with encephalographic (EEG) findings. CT findings were markedly abnormal in 6, slight with a sulcal enlargement in 3, and normal in 5. In the group of markedly abnormal CT findings, focal abnormal low density areas were detected in 2, severe generalized cerebral atrophy in one, and severe atrophy of the right hemisphere in one. EEG findings included focal paroxysmal abnormality of high voltage slow burst at the left frontal dominance and positive spike on the right hemisphere. Epileptic seizure and depressed sensorium seemed to be related to CT abnormality. In 3 patients with epileptic seizures, their symptoms were closely related to CT abnormality. Parkinsonisms and depressed sensorium were also related to CT abnormality. (Namekawa, K)

  14. Repeatability of tumour hypoxia imaging using [{sup 18}F]EF5 PET/CT in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Silvoniemi, Antti [University of Turku, Turku PET Centre (Finland); Turku University Hospital, Department of Otorhinolaryngology - Head and Neck Surgery (Finland); Suilamo, Sami [Turku University Hospital, Department of Oncology and Radiotherapy (Finland); Turku University Hospital, Department of Medical Physics (Finland); Laitinen, Timo; Forsback, Sarita; Solin, Olof [University of Turku, Turku PET Centre (Finland); Loeyttyniemi, Eliisa [University of Turku, Department of Biostatistics, Turku (Finland); Vaittinen, Samuli [Turku University Hospital, Department of Pathology (Finland); Saunavaara, Virva [University of Turku, Turku PET Centre (Finland); Turku University Hospital, Department of Medical Physics (Finland); Groenroos, Tove J.; Minn, Heikki [University of Turku, Turku PET Centre (Finland); Turku University Hospital, Department of Oncology and Radiotherapy (Finland)

    2018-02-15

    Hypoxia contributes to radiotherapy resistance and more aggressive behaviour of several types of cancer. This study was designed to evaluate the repeatability of intratumour uptake of the hypoxia tracer [{sup 18}F]EF5 in paired PET/CT scans. Ten patients with newly diagnosed head and neck cancer (HNC) received three static PET/CT scans before chemoradiotherapy: two with [{sup 18}F]EF5 a median of 7 days apart and one with [{sup 18}F]FDG. Metabolically active primary tumour volumes were defined in [{sup 18}F]FDG images and transferred to co-registered [{sup 18}F]EF5 images for repeatability analysis. A tumour-to-muscle uptake ratio (TMR) of 1.5 at 3 h from injection of [{sup 18}F]EF5 was used as a threshold representing hypoxic tissue. In 10 paired [{sup 18}F]EF5 PET/CT image sets, SUVmean, SUVmax, and TMR showed a good correlation with the intraclass correlation coefficients of 0.81, 0.85, and 0.87, respectively. The relative coefficients of repeatability for these parameters were 15%, 17%, and 10%, respectively. Fractional hypoxic volumes of the tumours in the repeated scans had a high correlation using the Spearman rank correlation test (r = 0.94). In a voxel-by-voxel TMR analysis between the repeated scans, the mean of Pearson correlation coefficients of individual patients was 0.65. The mean (± SD) difference of TMR in the pooled data set was 0.03 ± 0.20. Pretreatment [{sup 18}F]EF5 PET/CT within one week shows high repeatability and is feasible for the guiding of hypoxia-targeted treatment interventions in HNC. (orig.)

  15. 'Out of hours' adult CT head interpretation by senior emergency department staff following an intensive teaching session: a prospective blinded pilot study of 405 patients.

    Science.gov (United States)

    Jamal, Karim; Mandel, Laura; Jamal, Leila; Gilani, Shamim

    2014-06-01

    Cranial CT is the gold standard for the investigation of intracranial emergencies. The aim of this pilot study was to audit whether senior emergency physicians were able to report CT head scans accurately and reliably having attended structured teaching. Senior emergency physicians attended a 3 h teaching session. Following this, they independently reported adult CT head scans between 22:00 and 08:00 using a pro forma. CT head examinations performed in this 'out of hours' period were formally reported by a consultant radiologist on the following morning. Data were collected in a blinded fashion over an 8-month period. 405 adult CT head examinations were performed. 360 pro formas were available for analysis, and the rest were excluded either because a consultant radiologist had been rung to discuss the results (five patients) or because the pro forma was not completed (40 patients). Concordance between consultant radiologists and emergency physicians was found in 339 (94%) of the cases (κ coefficient 0.78). None of the discordant cases was managed inappropriately or had an adverse clinical outcome. All cases of extradural, subdural and subarachnoid haemorrhage were detected by emergency physicians. In conclusion, we feel that this model can be employed as a safe and long-term alternative provided that the radiology department are committed to providing ongoing teaching and that a database is maintained to highlight problem areas. Emergency physicians need to remember that the clinical status of the patient must never be ignored, irrespective of their CT head findings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. CT scanning of the breast in problem cases

    Energy Technology Data Exchange (ETDEWEB)

    John, V.; Ewen, K. (Essen Univ. (Gesamthochschule) (Germany, F.R.). Radiologisches Zentrum; Zentralstelle fuer Sicherheitstechnik, Duesseldorf (Germany, F.R.))

    1989-09-01

    This is a report of the experience with 200 patients who during 1981 to 1984 underwent breast scanning on a conventional body scanner. Pre- and post-contrast scans of the breast were obtained. A postcontrast enhancement of 50 HU and more turned out to be specific for malignant lesions. Radiation dose to the breast was in the same range as with high filtration xeromammography and high resolution film-screen mammography with additional grid. Breast scanning is recommended in cases in which mammography alone is of limited value, including dense fibrocystic breasts in women at high risk, follow-up in breast cancer patients after breast conserving therapy, in patients with silastic implants and in the follow-up of breasts with huge scars due to multiple biopsies. (orig.).

  17. Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging

    International Nuclear Information System (INIS)

    Thornton, A.F. Jr.; Ten Haken, R.K.; Gerhardsson, A.; Correll, M.

    1991-01-01

    A mask/marker immobilization system for the routine radiation therapy treatment of head and neck disease is described, utilizing a commercially available thermoplastic mesh, indexed and mounted for a rigid frame attached to the therapy couch. Designed to permit CT, MRI, and PET diagnostics scans of the patient to be performed in the simulation and treatment position employing the same mask, the system has been tested in order to demonstrate the reproducibility of immobilization throughout a radical course of irradiation. Three-dimensional analysis of patient position over an 8-week course of daily radiation treatment has been performed for 9 patients from digitization of anatomic points identified on orthogonal radiographs. Studies employing weekly constructed system permits rapid mask formation to be performed on the treatment simulator, resulting in an immobilization device comparable to masks produced with vacuum-forming techniques. Details of motion analysis and central axis CT, MRI, and PET markers are offered. (author). 16 refs.; 3 figs

  18. Estimating local noise power spectrum from a few FBP-reconstructed CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Rongping, E-mail: rongping.zeng@fda.hhs.gov; Gavrielides, Marios A.; Petrick, Nicholas; Sahiner, Berkman; Li, Qin; Myers, Kyle J. [Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland 20993 (United States)

    2016-01-15

    Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has the same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available

  19. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  20. Some practical aspects of dual-energy CT scanning

    International Nuclear Information System (INIS)

    Dunscombe, P.B.; Katz, D.E.; Stacey, A.J.

    1984-01-01

    Using the dual-energy scanning method developed by Brooks (1977), and making slow x-ray scans at 100 kVp, 35 mA and 140 kVp, 20 mA, measurements were made of electron density and effective atomic number in the lumbar spines of 36 patients aged from 22 to 87 years, and not known to be suffering from conditions which result in osteoporosis or osteomalacia. The authors discuss in detail the sources of experimental error which contributed to the large measured spread of normal values of electron density and effective atomic number. (U.K.)

  1. Some practical aspects of dual-energy CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Dunscombe, P.B.; Katz, D.E.; Stacey, A.J. (Charing Cross Group of Hospitals, London (UK))

    1984-01-01

    Using the dual-energy scanning method developed by Brooks (1977), and making slow x-ray scans at 100 kVp, 35 mA and 140 kVp, 20 mA, measurements were made of electron density and effective atomic number in the lumbar spines of 36 patients aged from 22 to 87 years, and not known to be suffering from conditions which result in osteoporosis or osteomalacia. The authors discuss in detail the sources of experimental error which contributed to the large measured spread of normal values of electron density and effective atomic number.

  2. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams

    International Nuclear Information System (INIS)

    Paiva, F.G.

    2017-01-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification

  3. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    Science.gov (United States)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  4. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  5. A consideration of a measuring point of ventricular dilatation on CT scanning

    International Nuclear Information System (INIS)

    Kuno, Koichi; Miyake, Kazuo

    1980-01-01

    Ventricular dilatation has been judged by pneumo-ventricurography, pneumo-encepharography and carotid angiography (CAG), though all these procedures are very uncomfortable for patients. On the other hand, the CT scan is very easy as a follow-up study of ventricular dilatation for a weak patient. We carried out the CT scan (Hitachi CT-H 250 Scanner, NaI detector) and CAG on 84 cases. The ventricular dilatation was judged by the degree of outstretch of the strio-thalamic vein on an AP view of the phrebogram, classified into 3 types. For all three types classified by the phrebogram, we studied various measuring points of the ventricle on the CT scan. The portions measured on the CT scan were: (1) the frontal cerebro-ventricular index (F-CVI), (2) the bicaudate cerebro-ventricular index (Bicaud-CVI), and (3) the maximum Monro's cerebro-ventricular index (M-CVI), the width of the frontal horn, and the thickness of the ventricular body. The following results were obtained: (1) In measuring the ventricular size on the CT scan, the most interrelated point with the ventricular dilatation is the M-CVI - the ratio of the largest width of the body through the Monro foramen to the width of the brain. In this case, however, the width of the frontal horn and of the body should also be considered. (2) Voltage and electric current changed the EMI-number, but did not alter the measuring value. In this case, the width and the level should be kept constant. (3) The group with the marked ventricular dilatation has a larger value of the CT scan than its value of GAG. (4) The normal value of the M-CVI is 24 +- 3%, moreover, the width of the frontal horn is less than 10 mm, and the thickness of the ventricular body is less than 17 mm. (author)

  6. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities

    International Nuclear Information System (INIS)

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R.; McNeel, Sandra V.; Cohen, Ronald A.

    2014-01-01

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care. (orig.)

  7. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R.; McNeel, Sandra V. [Environmental Health Investigations Branch, California Department of Public Health, Richmond, CA (United States); Cohen, Ronald A. [Children' s Hospital and Research Center Oakland, Department of Radiology, Oakland, CA (United States)

    2014-05-15

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuse