WorldWideScience

Sample records for ct clot formation

  1. Formation of blood clot on biomaterial implants influences bone healing.

    Science.gov (United States)

    Shiu, Hoi Ting; Goss, Ben; Lutton, Cameron; Crawford, Ross; Xiao, Yin

    2014-12-01

    The first step in bone healing is forming a blood clot at injured bones. During bone implantation, biomaterials unavoidably come into direct contact with blood, leading to a blood clot formation on its surface prior to bone regeneration. Despite both situations being similar in forming a blood clot at the defect site, most research in bone tissue engineering virtually ignores the important role of a blood clot in supporting healing. Dental implantology has long demonstrated that the fibrin structure and cellular content of a peri-implant clot can greatly affect osteoconduction and de novo bone formation on implant surfaces. This article reviews the formation of a blood clot during bone healing in relation to the use of platelet-rich plasma (PRP) gels. It is implicated that PRP gels are dramatically altered from a normal clot in healing, resulting in conflicting effect on bone regeneration. These results indicate that the effect of clots on bone regeneration depends on how the clots are formed. Factors that influence blood clot structure and properties in relation to bone healing are also highlighted. Such knowledge is essential for developing strategies to optimally control blood clot formation, which ultimately alter the healing microenvironment of bone. Of particular interest are modification of surface chemistry of biomaterials, which displays functional groups at varied composition for the purpose of tailoring blood coagulation activation, resultant clot fibrin architecture, rigidity, susceptibility to lysis, and growth factor release. This opens new scope of in situ blood clot modification as a promising approach in accelerating and controlling bone regeneration.

  2. Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots.

    Science.gov (United States)

    Zubairova, Laily D; Nabiullina, Roza M; Nagaswami, Chandrasekaran; Zuev, Yuriy F; Mustafin, Ilshat G; Litvinov, Rustem I; Weisel, John W

    2015-12-04

    Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1-0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis.

  3. Massive clot formation after tooth extraction

    Directory of Open Access Journals (Sweden)

    Santosh Hunasgi

    2015-01-01

    Full Text Available Oral surgical procedures mainly tooth extraction can be related with an extended hemorrhage owed to the nature of the process resulting in an "open wound." The attempt of this paper is to present a case of massive postoperative clot formation after tooth extraction and highlight on the oral complications of surgical procedures. A 32-year-old male patient reported to the Dental Clinic for evaluation and extraction of grossly decayed 46. Clinical evaluation of 46 revealed root stumps. Extraction of the root stumps was performed, and it was uneventful. Hemostasis was achieved and postsurgical instructions were specified to the patient. The patient reported to the clinic, the very subsequent morning with a criticism of bleeding at the extraction site. On clinical examination, bleeding was noted from the socket in relation to 46. To control bleeding, oral hemostatic drugs Revici - E (Ethamsylate 500 mg was prescribed and bleeding was stopped in 2 h. However, a massive clot was formed at the extraction site. Further, this clot resolved on its own in 1-week time. Despite the fact that dental extraction is considered to be a minor surgical procedure, some cases may present with life-threatening complications including hemorrhage. Vigilant and significant history taking, physical and dental examinations prior to dental procedures are a must to avoid intraoperative and postoperative complications.

  4. Fluid Mechanics of Blood Clot Formation.

    Science.gov (United States)

    Fogelson, Aaron L; Neeves, Keith B

    2015-01-01

    Intravascular blood clots form in an environment in which hydrodynamic forces dominate and in which fluid-mediated transport is the primary means of moving material. The clotting system has evolved to exploit fluid dynamic mechanisms and to overcome fluid dynamic challenges to ensure that clots that preserve vascular integrity can form over the wide range of flow conditions found in the circulation. Fluid-mediated interactions between the many large deformable red blood cells and the few small rigid platelets lead to high platelet concentrations near vessel walls where platelets contribute to clotting. Receptor-ligand pairs with diverse kinetic and mechanical characteristics work synergistically to arrest rapidly flowing cells on an injured vessel. Variations in hydrodynamic stresses switch on and off the function of key clotting polymers. Protein transport to, from, and within a developing clot determines whether and how fast it grows. We review ongoing experimental and modeling research to understand these and related phenomena.

  5. Determination of enoxaparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent.

    Science.gov (United States)

    Schaden, Eva; Schober, Andreas; Hacker, Stefan; Spiss, Christian; Chiari, Astrid; Kozek-Langenecker, Sibylle

    2010-04-01

    Drug monitoring of low molecular weight heparin is generally not recommended, but could be reasonable in critically ill patients, whose risk for bleeding or thrombosis shows a high interpatient variability. Anti-Xa assays are not available around the clock even in central hospitals, whereas rotational thrombelastometry (ROTEM) becomes increasingly used at the bedside. Prothrombinase-induced clotting time (PiCT) reagent allows determination of factor Xa-inhibition in plasma. The aim of our study was to evaluate enoxaparin determination in whole blood with the ROTEM using specific test modifications, including PiCT. After ethics committee's approval, citrated whole blood obtained from overall 16 healthy volunteers was incubated with enoxaparin at 16 different anti-Xa concentrations. Main endpoint was the clotting time (CT) in ROTEM representing initial activation of clot formation. CT was determined in the new PiCT-ROTEM test, in a low-tissue factor-activated modification (LowTF-ROTEM) as well as in the commercially available heparin-sensitive ROTEM assays (HEPTEM and INTEM). In the absence of enoxaparin, CT values were 168.6 +/- 6.1 s (PiCT-ROTEM), 247.3 +/- 18.6 s (LowTF-ROTEM), and -6.2 +/- 7.9 s (INTEM-HEPTEM). A linear dependency (P anti-Xa concentration and CT was found for PiCT-ROTEM, LowTF-ROTEM, and for INTEM-HEPTEM with correlation coefficients of 0.93 for PiCT-ROTEM, 0.94 for LowTF-ROTEM, and 0.81 for INTEM-HEPTEM. This in-vitro experiment demonstrates a strong correlation between enoxaparin anti-Xa concentrations and specific ROTEM tests. These promising assays should be further evaluated for monitoring anticoagulation in high-risk patients in clinical studies.

  6. A hypothesis: factor VII governs clot formation, tissue repair and apoptosis.

    Science.gov (United States)

    Coleman, Lewis S

    2007-01-01

    A hypothesis: thrombin is a "Universal Enzyme of Energy Transduction" that employs ATP energy in flowing blood to activate biochemical reactions and cell effects in both hemostasis and tissue repair. All cells possess PAR-1 (thrombin) receptors and are affected by thrombin elevations, and thrombin effects on individual cell types are determined by their unique complement of PAR-1 receptors. Disruption of the vascular endothelium (VE) activates a tissue repair mechanism (TRM) consisting of the VE, tissue factor (TF), and circulating Factors VII, IX and X that governs localized thrombin elevations to activate clot formation and cellular effects that repair tissue damage. The culmination of the repair process occurs with the restoration of the VE followed by declines in thrombin production that causes Apoptosis ("programmed cell death") in wound-healing fibroblasts, which functions as a mechanism to draw wound edges together. The location and magnitude of TRM activity governs the location and magnitude of Factor VIII activity and clot formation, but the large size of Factor VIII prevents it from penetrating the clot formed by its activity, so that its effects are self-limiting. Factors VII, IX and X function primarily as tissue repair enzymes, while Factor VIII and Factor XIII are the only serine protease enzymes in the "Coagulation Cascade" that are exclusively associated with hemostasis.

  7. Influence of Interleukin-1 Beta on Platelet-Poor Plasma Clot Formation: A Potential Impact on Early Bone Healing.

    Directory of Open Access Journals (Sweden)

    Xin Wang

    Full Text Available Hematoma quality (especially the fibrin matrix plays an important role in the bone healing process. Here, we investigated the effect of interleukin-1 beta (IL-1β on fibrin clot formation from platelet-poor plasma (PPP.Five-milliliter of rat whole-blood samples were collected from the hepatic portal vein. All blood samples were firstly standardized via a thrombelastograph (TEG, blood cell count, and the measurement of fibrinogen concentration. PPP was prepared by collecting the top two-fifths of the plasma after centrifugation under 400 × g for 10 min at 20°C. The effects of IL-1β cytokines on artificial fibrin clot formation from PPP solutions were determined by scanning electronic microscopy (SEM, confocal microscopy (CM, turbidity, and clot lysis assays.The lag time for protofibril formation was markedly shortened in the IL-1β treatment groups (243.8 ± 76.85 in the 50 pg/mL of IL-1β and 97.5 ± 19.36 in the 500 pg/mL of IL-1β compared to the control group without IL-1β (543.8 ± 205.8. Maximal turbidity was observed in the control group. IL-1β (500 pg/mL treatment significantly decreased fiber diameters resulting in smaller pore sizes and increased density of the fibrin clot structure formed from PPP (P < 0.05. The clot lysis assay revealed that 500 pg/mL IL-1β induced a lower susceptibility to dissolution due to the formation of thinner and denser fibers.IL-1β can significantly influence PPP fibrin clot structure, which may affect the early bone healing process.

  8. Computational Study of Thrombus Formation and Clotting Factor Effects under Venous Flow Conditions

    Science.gov (United States)

    2016-04-26

    domain used in our thrombus formation simulations. Fig. 2 B shows the 3D geometry of the flow-chamber section consisting of two channels measuring 250 60...ArticleComputational Study of Thrombus Formation and Clotting Factor Effects under Venous Flow ConditionsVijay Govindarajan,1 Vineet Rakesh,1 Jaques...understanding of thrombus formation as a physicochemical process that has evolved to protect the integrity of the human vasculature is critical to our ability to

  9. Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study.

    Science.gov (United States)

    Brinjikji, Waleed; Michalak, Gregory; Kadirvel, Ramanathan; Dai, Daying; Gilvarry, Michael; Duffy, Sharon; Kallmes, David F; McCollough, Cynthia; Leng, Shuai

    2017-06-01

    Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.

  10. Hot-clot artifacts in the lung parenchyma on F-18-fluorodeoxyglucose position emission tomography/CT due to faulty injection techniques: Two case report

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, Elif; Yildirim, Nilufer; Keskin, Mutlay; Kandemir, Zuhai; Turkolmez, Seyda [Dept. of Nuclear Medicine, Ataturk Training and Research Hospital, Ankara (Turkmenistan)

    2014-08-15

    F-18-fluorodeoxyglucose (FDG) positron emission tomography/CT is an important whole-body imaging tool in the oncology and widely utilized to stage and restage various malignancies. The findings of significant focal accumulation of FDG in the lung parenchyma in the absence of corresponding CT abnormalities are related to the lung microembolism and known as hot-clot artifacts. Herein we present two cases with focal FDG uptake in the lung parenchyma with no structural lesions on the CT scan and discuss the possible mechanisms.

  11. Hot-clot artifacts in the lung parenchyma on F-18-fluorodeoxyglucose position emission tomography/CT due to faulty injection techniques: Two case report

    International Nuclear Information System (INIS)

    Ozdemir, Elif; Yildirim, Nilufer; Keskin, Mutlay; Kandemir, Zuhai; Turkolmez, Seyda

    2014-01-01

    F-18-fluorodeoxyglucose (FDG) positron emission tomography/CT is an important whole-body imaging tool in the oncology and widely utilized to stage and restage various malignancies. The findings of significant focal accumulation of FDG in the lung parenchyma in the absence of corresponding CT abnormalities are related to the lung microembolism and known as hot-clot artifacts. Herein we present two cases with focal FDG uptake in the lung parenchyma with no structural lesions on the CT scan and discuss the possible mechanisms.

  12. EVALUATION OF THE COMPUTED TOMOGRAPHIC "SENTINEL CLOT SIGN" TO IDENTIFY BLEEDING ABDOMINAL ORGANS IN DOGS WITH HEMOABDOMEN.

    Science.gov (United States)

    Specchi, Swan; Auriemma, Edoardo; Morabito, Simona; Ferri, Filippo; Zini, Eric; Piola, Valentina; Pey, Pascaline; Rossi, Federica

    2017-01-01

    The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen. © 2016 American College of Veterinary Radiology.

  13. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    International Nuclear Information System (INIS)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi; Morikage, Noriyasu; Sano, Yuichi; Suga, Kazuyoshi

    2013-01-01

    Background: Dual-energy perfusion CT (DE p CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE p CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE p CT using a 64-slice dual-source CT. DE p CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V 120 ), 1-15 HU (V 15 ), 1-10 HU (V 10 ), and 1-5 HU (V 5 ). Each relative ratio per V 120 was expressed as the %V 15 , %V 10 , and %V 5 . Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V 15 , V 10 , V 5 , %V 15 , %V 10 , and %V 5 were also significantly higher than those without IPC (P = 0.001). %V 5 had a better correlation with D-dimer (r = 0.30, P p CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE

  14. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  15. Thermal Blood Clot Formation and use in Microfluidic Device Valving Applications

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Shi, Wendian (Inventor); Guo, Luke (Inventor)

    2014-01-01

    The present invention provides a method of forming a blood-clot microvalve by heating blood in a capillary tube of a microfluidic device. Also described are methods of modulating liquid flow in a capillary tube by forming and removing a blood-clot microvalve.

  16. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  17. A simple clot based assay for detection of procoagulant cell-derived microparticles.

    Science.gov (United States)

    Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati

    2016-05-01

    Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.

  18. Alkali treatment of microrough titanium surfaces affects macrophage/monocyte adhesion, platelet activation and architecture of blood clot formation

    Directory of Open Access Journals (Sweden)

    V Milleret

    2011-05-01

    Full Text Available Titanium implants are most commonly used for bone augmentation and replacement due to their favorable osseointegration properties. Here, hyperhydrophilic sand-blasted and acid-etched (SBA titanium surfaces were produced by alkali treatment and their responses to partially heparinized whole human blood were analyzed. Blood clot formation, platelet activation and activation of the complement system was analyzed revealing that exposure time between blood and the material surface is crucial as increasing exposure time results in higher amount of activated platelets, more blood clots formed and stronger complement activation. In contrast, the number of macrophages/monocytes found on alkali-treated surfaces was significantly reduced as compared to untreated SBA Ti surfaces. Interestingly, when comparing untreated to modified SBA Ti surfaces very different blood clots formed on their surfaces. On untreated Ti surfaces blood clots remain thin (below 15 mm, patchy and non-structured lacking large fibrin fiber networks whereas blood clots on differentiated surfaces assemble in an organized and layered architecture of more than 30 mm thickness. Close to the material surface most nucleated cells adhere, above large amounts of non-nucleated platelets remain entrapped within a dense fibrin fiber network providing a continuous cover of the entire surface. These findings might indicate that, combined with findings of previous in vivo studies demonstrating that alkali-treated SBA Ti surfaces perform better in terms of osseointegration, a continuous and structured layer of blood components on the blood-facing surface supports later tissue integration of an endosseous implant.

  19. Transfusion packages for massively bleeding patients: the effect on clot formation and stability as evaluated by Thrombelastograph (TEG)

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Bochsen, L.; Stensballe, J.

    2008-01-01

    We investigated the effect of administering a transfusion package encompassing 5 red blood cells (RBC), 5 fresh frozen plasma (FFP), and 2 platelet concentrates (PC) on clot formation and stability as evaluated by Thrombelastograph (TEG) in 10 patients presenting with massive bleeding. Blood was ...

  20. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  1. Freeze-dried plasma enhances clot formation and inhibits fibrinolysis in the presence of tissue plasminogen activator similar to pooled liquid plasma.

    Science.gov (United States)

    Huebner, Benjamin R; Moore, Ernest E; Moore, Hunter B; Sauaia, Angela; Stettler, Gregory; Dzieciatkowska, Monika; Hansen, Kirk; Banerjee, Anirban; Silliman, Christopher C

    2017-08-01

    Systemic hyperfibrinolysis is an integral part of trauma-induced coagulopathy associated with uncontrolled bleeding. Recent data suggest that plasma-first resuscitation attenuates hyperfibrinolysis; however, the availability, transport, storage, and administration of plasma in austere environments remain challenging and have limited its use. Freeze-dried plasma (FDP) is a potential alternative due to ease of storage, longer shelf life, and efficient reconstitution. FDP potentially enhances clot formation and resists breakdown better than normal saline (NS) and albumin and similar to liquid plasma. Healthy volunteers underwent citrated blood draw followed by 50% dilution with NS, albumin, pooled plasma (PP), or pooled freeze-dried plasma (pFDP). Citrated native and tissue plasminogen activator (t-PA)-challenge (75 ng/mL) thrombelastography were done. Proteins in PP, pFDP, and albumin were analyzed by mass spectroscopy. pFDP and PP had superior clot-formation rates (angle) and clot strength (maximum amplitude) compared with NS and albumin in t-PA-challenge thrombelastographies (angle: pFDP, 67.9 degrees; PP, 67.8 degrees; NS, 40.6 degrees; albumin, 35.8 degrees; maximum amplitude: pFDP, 62.4 mm; PP, 63.5 mm; NS, 44.8 mm; albumin, 41.1 mm). NS and albumin dilution increased susceptibility to t-PA-induced hyperfibrinolysis compared with pFDP and PP (NS, 62.4%; albumin, 62.6%; PP, 8.5%; pFDP, 6.7%). pFDP was similar to PP in the attenuation of t-PA-induced fibrinolysis. Most proteins (97%) were conserved during the freeze-dry process, with higher levels in 12% of pFDP proteins compared with PP. pFDP enhances clot formation and attenuates hyperfibrinolysis better than NS and albumin and is a potential alternative to plasma resuscitation in the treatment of hemorrhagic shock. © 2017 AABB.

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  3. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ... Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are Blood Clots ...

  4. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... For Patients Blood Disorders Blood Clots Blood Clotting & Pregnancy If you are pregnant, or you have just ... The risk of developing a blood clot during pregnancy is increased by the following: Previous blood clots ...

  5. The Phosphatase Inhibitor Calyculin-A Impairs Clot Retraction, Platelet Activation, and Thrombin Generation

    Directory of Open Access Journals (Sweden)

    Renáta Hudák

    2017-01-01

    Full Text Available The aim of this study was to investigate the effect of the serine/threonine protein phosphatase inhibitor, calyculin-A (CLA, on clot formation and on the procoagulant activity of human platelets. Platelet-rich plasma (PRP samples were preincubated with buffer or CLA and subsequently platelets were activated by the protease-activated receptor 1 (PAR-1 activator, thrombin receptor activating peptide (TRAP. Clot retraction was detected by observing clot morphology up to 1 hour, phosphatidylserine- (PS- expression was studied by flow cytometry, and thrombin generation was measured by a fluorimetric assay. For the intracellular Ca2+ assay, platelets were loaded with calcium-indicator dyes and the measurements were carried out using a ratiometric method with real-time confocal microscopy. CLA preincubation inhibited clot retraction, PS-expression, and thrombin formation. TRAP activation elicited Ca2+ response and PS-expression in a subset of platelets. The activated PRP displayed significantly faster and enhanced thrombin generation compared to nonactivated samples. CLA pretreatment abrogated PS-exposure and clot retraction also in TRAP-activated samples. As a consequence of the inhibitory effect on calcium elevation and PS-expression, CLA significantly downregulated thrombin generation in PRP. Our results show that CLA pretreatment may be a useful tool to investigate platelet activation mechanisms that contribute to clot formation and thrombin generation.

  6. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... with Your Doctor Patient Group Links Advocacy Toolkit Home For Patients Blood Disorders Blood Clots Blood Clotting & Pregnancy If you are pregnant, or you have just had a baby, you are at greater risk of developing a blood clot. Blood clots in pregnant women tend to form in the deep veins of ...

  7. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  8. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... all publications For Patients Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and Travel DVT Myths vs. Facts Blood ...

  9. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... resource to help stay current with the latest advances in the field Hematology 2017 A collection of articles ... Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ...

  10. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... blood clots are treated with an anticoagulant, a medicine that prevents the blood from clotting. Certain anticoagulants are safe to use during pregnancy. back to top Are Blood Clots Preventable? There ...

  11. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... of articles from the 2017 ASH Annual Meeting Education Program Blood: How I Treat A compendium of Blood articles updated ... Clots Blood Clotting and Pregnancy Clots and Travel DVT Myths vs. Facts Blood ...

  12. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Blood Clots Blood Clotting and Pregnancy Clots and Travel DVT Myths vs. Facts Blood Disorder Fact Sheets ... that occurs when a DVT breaks off and travels to the blood vessels of the lungs. DVT ...

  13. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Section Action Alerts Advocacy Toolkit Policy News Sickle Cell Disease Initiative Policy Statements Congressional Fellowship Testimony and ... Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ...

  14. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... back to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with ... you think you have one. If you are pregnant and have concerns about blood clots, talk with ...

  15. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... clot. Blood clots in pregnant women tend to form in the deep veins of the legs or ... potentially dangerous to your baby. Blood clots can form inside the placenta, cutting off blood flow and ...

  16. Case series: Bladder clot evacuation using a prostate morcellation device.

    Science.gov (United States)

    Doersch, Karen M; Navetta, Andrew F; Bird, Erin T; El Tayeb, Marawan M

    2017-07-01

    We sought to provide a technical update on the use of a prostate morcellator device (PMD) to manage organized blood clots of the bladder following laser prostatectomy. Herein, we describe our experience in using the Wolf Piranha morcellator in managing organized bladder blood clots supplemented with a retrospective chart review of the patients in whom this procedure was performed. Six patients, all male with a mean age of 75 ± 8.9 years, had organized bladder clots following either holmium laser enucleation or photoselective vaporization of the prostate managed with a PMD. Clots were recognized based on hematuria or urinary retention a median of 3.5 days following the aforementioned procedures. Initial management was attempted with more conservative measures, including a three-way Foley catheter, followed by cystoscopy with an Ellik evacuator, or a glass Tommey syringe. Morcellation times were a mean of 10.2 ± 6.15 minutes (range 2-18). This technique was able to manage clots that were an average of 173.3 ± 115.9 cc in size. The procedure was well-tolerated. No patients experienced intraoperative or morcellator-related complications. Benign prostatic hypertrophy frequently requires surgical endoscopic management and can be complicated by hematuria and bladder blood clot formation. When these clots become organized, this can lead to urinary retention and the required management, evacuation, may be difficult. The use of a Wolf Piranha PMD is a safe, well-tolerated, and effective in evacuating organized blood clots of the bladder.

  17. Clot formation and lysis in platelet rich plasma of healthy donors and patients with resistant hypertension

    Directory of Open Access Journals (Sweden)

    I. I. Patalakh

    2018-04-01

    Full Text Available Hemostatic balance in blood is affected by numerous factors, including coagulation and fibrinolytic proteins, the wide spectrum of their inhibitors, and blood cells. Since platelets can participate in contradictory processes, they significantly complicate the whole picture. Therefore, nowadays the development of global assays of hemostasis, which can reflect the physiological process of hemostasis and can be used for point-of-care diagnosis of thrombosis, is crucial. This paper outlines a new approach we used to analyze the capabilities of clot waveform analysis tools to distinguish the response of platelet-rich plasma from healthy donors and patients with arterial hypertension caused by stimulation of coagulation and lysis (with exogenous thrombin and recombinant tissue-type plasminogen activator, respectively. In donor plasma, when the clot degradation was accompanied by 40 IU/ml of recombinant tissue-type plasminogen activator, platelets potentiated fibrinolysis more than coagulation, which ultimately shifts the overall balance to a profibrinolytic state. At the same time, for patients with hypertension, platelets, embedded in clot obtained from platelet-rich plasma, showed a weaker ability to stimulate fibrinolysis. The obtained data gives the evidence that platelets can act not only as procoagulants but also as profibrinolytics. By simultaneously amplifying coagulation and fibrinolysis, making their rates comparable, platelets would control plasma procoagulant activity, thereby regulating local hemostatic balance, the size and lifetime of the clot. Moreover, clot waveform analysis may be used to distinguish the effects of platelet-rich plasma on clotting or lysis of fibrin clots in healthy donors and patients with essential hypertension.

  18. Mechanical Stability and Fibrinolytic Resistance of Clots Containing Fibrin, DNA, and Histones*

    Science.gov (United States)

    Longstaff, Colin; Varjú, Imre; Sótonyi, Péter; Szabó, László; Krumrey, Michael; Hoell, Armin; Bóta, Attila; Varga, Zoltán; Komorowicz, Erzsébet; Kolev, Krasimir

    2013-01-01

    Neutrophil extracellular traps are networks of DNA and associated proteins produced by nucleosome release from activated neutrophils in response to infection stimuli and have recently been identified as key mediators between innate immunity, inflammation, and hemostasis. The interaction of DNA and histones with a number of hemostatic factors has been shown to promote clotting and is associated with increased thrombosis, but little is known about the effects of DNA and histones on the regulation of fibrin stability and fibrinolysis. Here we demonstrate that the addition of histone-DNA complexes to fibrin results in thicker fibers (increase in median diameter from 84 to 123 nm according to scanning electron microscopy data) accompanied by improved stability and rigidity (the critical shear stress causing loss of fibrin viscosity increases from 150 to 376 Pa whereas the storage modulus of the gel increases from 62 to 82 pascals according to oscillation rheometric data). The effects of DNA and histones alone are subtle and suggest that histones affect clot structure whereas DNA changes the way clots are lysed. The combination of histones + DNA significantly prolongs clot lysis. Isothermal titration and confocal microscopy studies suggest that histones and DNA bind large fibrin degradation products with 191 and 136 nm dissociation constants, respectively, interactions that inhibit clot lysis. Heparin, which is known to interfere with the formation of neutrophil extracellular traps, appears to prolong lysis time at a concentration favoring ternary histone-DNA-heparin complex formation, and DNase effectively promotes clot lysis in combination with tissue plasminogen activator. PMID:23293023

  19. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  20. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

    Directory of Open Access Journals (Sweden)

    Robinson RA

    2013-05-01

    Full Text Available Ronald A Robinson, Luke H Herbertson, Srilekha Sarkar Das, Richard A Malinauskas, William F Pritchard, Laurence W GrossmanOffice of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USAAbstract: The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm, length-to-diameter ratios (1:1, 3:1, 10:1, and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the

  1. Determining Human Clot Lysis Time (in vitro with Plasminogen/Plasmin from Four Species (Human, Bovine, Goat, and Swine

    Directory of Open Access Journals (Sweden)

    Omaira Cañas Bermúdez

    2015-05-01

    Full Text Available Cardiovascular disease is the leading cause of death worldwide, including failures in the plasminogen/plasmin system which is an important factor in poor lysis of blood clots. This article studies the fibrinolytic system in four species of mammals, and it identifies human plasminogen with highest thrombolysis efficiency. It examines plasminogen from four species (human, bovine, goat, and swine and identifies the most efficient one in human clot lysis in vitro. All plasminogens were identically purified by affinity chromatography. Human fibrinogen was purified by fractionation with ethanol. The purification of both plasminogen and fibrinogen was characterized by one-dimensional SDS-PAGE (10%. Human clot formation in vitro and its dissolution by plasminogen/plasmin consisted of determining lysis time from clot formation to its dilution. Purification of proteins showed greater than 95% purity, human plasminogen showed greater ability to lyse clot than animal plasminogen. The article concludes that human plasminogen/plasmin has the greatest catalysis and efficiency, as it dissolves human clot up to three times faster than that of irrational species.

  2. Blood Clotting and Pregnancy

    Science.gov (United States)

    ... blood clots A genetic predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) Multiple births Increased maternal age Other medical illness (e.g., cancer, infection) ...

  3. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... blood clots A genetic predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) Multiple births Increased maternal age Other medical illness (e.g., cancer, infection) ...

  4. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... increased by the following: Previous blood clots A genetic predisposition to blood clots Obesity Prolonged immobility (e. ... 2018 by American Society of Hematology Support Opportunities | Privacy Policy | Terms of Service | Contact Us

  5. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... an immediate impact on your practice Summit on Emerging Immunotherapies Registration Schedule & Program Meeting on Lymphoma Biology ... blood clots are treated with an anticoagulant, a medicine that prevents the blood from clotting. Certain anticoagulants ...

  6. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... 0544 | Fax 202-776-0545 ASH Store ASH Job Center ASH Apps Share Your Idea Donate Research ...

  7. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... are pregnant, or you have just had a baby, you are at greater risk of developing a ... Blood clots are also potentially dangerous to your baby. Blood clots can form inside the placenta, cutting ...

  8. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... pregnancy: Be aware of risk factors. Know your family history. Make sure your doctor knows about any ... blood clots or blood clotting disorders in your family. Remain active, with your doctor's approval. Be aware ...

  9. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... In This Section Agenda for Hematology Research Precision Medicine Initiative Research Registry Research Recommendations Research Programs and ... blood clots are treated with an anticoagulant, a medicine that prevents the blood from clotting. Certain anticoagulants ...

  10. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... these blood conditions and increase research on the causes, prevention, and treatment. Blood clots are also potentially ... Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are Blood Clots ...

  11. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... blood clots A genetic predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) ... of practicing hematologists in your area. Learn more AMERICAN SOCIETY OF HEMATOLOGY 2021 L Street NW, Suite ...

  12. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Be aware of risk factors. Know your family history. Make sure your doctor knows about any history of blood clots or blood clotting disorders in ... Support Opportunities | Privacy Policy | Terms of Service | Contact Us

  13. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... increased by the following: Previous blood clots A genetic predisposition to blood clots Obesity Prolonged immobility (e. ... Be aware of risk factors. Know your family history. Make sure your doctor knows about any history ...

  14. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... presentations, that can help you make an immediate impact on your practice Summit on Emerging Immunotherapies Registration ... blood clots are treated with an anticoagulant, a medicine that prevents the blood from clotting. Certain anticoagulants ...

  15. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... of Web links to patient groups and other organizations that provide information. back to top ASH Foundation ...

  16. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... Image Bank Advocacy Action Alerts Policy News Advocacy Leadership Institute Policy Statements Testimony & Correspondence Meetings ASH Annual ...

  17. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... Programs and Awards ASH Agenda for Hematology Research Education For Clinicians For Trainees For Educators For Patients ...

  18. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... This Section Action Alerts Advocacy Toolkit Policy News Sickle Cell Disease Initiative Policy Statements Congressional Fellowship Testimony and ... all publications For Patients Blood Basics Blood Disorders Anemia Bleeding Disorders Blood Cancers Blood Clots Blood Clotting ...

  19. Adenosine diphosphate-decorated chitosan nanoparticles shorten blood clotting times, influencing the structures and varying the mechanical properties of the clots

    Directory of Open Access Journals (Sweden)

    Chung TW

    2014-03-01

    Full Text Available Tze-Wen Chung,1,3 Pei-Yi Lin,2 Shoei-Shen Wang,2 Yen-Fung Chen31Department of Biomedical Engineering, National Yang-Ming University, 2Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan, Republic of China; 3Department of Chemical and Materials Engineering, National Yunlin University of Science and Technology, Yunlin, Taiwan, Republic of ChinaAbstract: Chitosan nanoparticles (NPs decorated with adenosine diphosphate (ADP (ANPs or fibrinogen (FNPs were used to fabricate hemostatic NPs that can shorten blood clotting time and prevent severe local hemorrhage. The structure and mechanical properties of the blood clot induced with ANP (clot/ANP or FNP (clot/FNP were also investigated. The NPs, ANPs, and FNPs, which had particle sizes of 245.1±14.0, 251.0±9.8, and 326.5±14.5 nm and zeta potentials of 24.1±0.5, 20.6±1.9, and 15.3±1.5 mV (n=4, respectively, were fabricated by ionic gelation and then decorated with ADP and fibrinogen. The zeta potentials and Fourier transform infrared (FTIR spectroscopy of the NPs confirmed that their surfaces were successfully coated with ADP and fibrinogen. The scanning electron microscope (SEM micrographs of the structure of the clot induced with "undecorated" chitosan NPs (clot/NP, clot/ANP, and clot/FNP (at 0.05 wt% were different, after citrated bloods had been recalcified by a calcium chloride solution containing NPs, ANPs, or FNPs. This indicated that many NPs adhered on the membrane surfaces of red blood cells, that ANPs induced many platelet aggregates, and that FNPs were incorporated into the fibrin network in the clots. Measurements of the blood clotting times (Tc of blood clot/NPs, clot/ANPs, and clot/FNPs, based on 90% of ultimate frequency shifts measured on a quartz crystal microbalance (QCM, were significantly (P<0.05 (n=4 shorter than that of a clot induced by a phosphate-buffered solution (PBS (clot/PBS (63.6%±3.1%, 48.3%±6.2%, and 63.2%±4.7%, respectively. The ∆F2

  20. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... harming your baby. Jump To: Am I at Risk? The risk of developing a blood clot during pregnancy is ... prevent blood clots during pregnancy: Be aware of risk factors. Know your family history. Make sure your ...

  1. The hydraulic permeability of blood clots as a function of fibrin and platelet density.

    Science.gov (United States)

    Wufsus, A R; Macera, N E; Neeves, K B

    2013-04-16

    Interstitial fluid flow within blood clots is a biophysical mechanism that regulates clot growth and dissolution. Assuming that a clot can be modeled as a porous medium, the physical property that dictates interstitial fluid flow is the hydraulic permeability. The objective of this study was to bound the possible values of the hydraulic permeability in clots formed in vivo and present relationships that can be used to estimate clot permeability as a function of composition. A series of clots with known densities of fibrin and platelets, the two major components of a clot, were formed under static conditions. The permeability was calculated by measuring the interstitial fluid velocity through the clots at a constant pressure gradient. Fibrin gels formed with a fiber volume fraction of 0.02-0.54 had permeabilities of 1.2 × 10(-1)-1.5 × 10(-4)μm(2). Platelet-rich clots with a platelet volume fraction of 0.01-0.61 and a fibrin volume fraction of 0.03 had permeabilities over a range of 1.1 × 10(-2)-1.5 × 10(-5)μm(2). The permeability of fibrin gels and of clots with platelet volume fraction of platelet volume fraction of >0.2 were modeled as a Brinkman medium of coarse solids (platelets) embedded in a mesh of fine fibers (fibrin). Our data suggest that the permeability of clots formed in vivo can vary by up to five orders of magnitude, with pore sizes that range from 4 to 350 nm. These findings have important implications for the transport of coagulation zymogens/enzymes in the interstitial spaces during clot formation, as well as the design of fibrinolytic drug delivery strategies. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. Examining platelet-fibrin interactions during traumatic shock in a swine model using platelet contractile force and clot elastic modulus.

    Science.gov (United States)

    White, Nathan J; Martin, Erika J; Brophy, Donald F; Ward, Kevin R

    2011-07-01

    A significant proportion of severely injured patients develop early coagulopathy, characterized by abnormal clot formation, which impairs resuscitation and increases mortality. We have previously demonstrated an isolated decrease in clot strength by thrombelastography in a swine model of nonresuscitated traumatic shock. In order to more closely examine platelet-fibrin interactions in this setting, we define the observed decrease in clot strength in terms of platelet-induced clot contraction and clot elastic modulus using the Hemostasis Analysis System (HAS) (Hemodyne Inc., Richmond, Virginia, USA). Whole blood was sampled for HAS measurements, metabolic measurements, cell counts, and fibrinogen concentration at baseline prior to injury and again at a predetermined level of traumatic shock defined by oxygen debt. Male swine (N=17) received femur fracture and controlled arterial hemorrhage to achieve an oxygen debt of 80 ml/kg. Platelet counts were unchanged, but fibrinogen concentration was reduced significantly during shock (167.6 vs. 66.7 mg/dl, P=0.0007). Platelet contractile force generated during clot formation did not change during shock (11.7 vs. 10.4 kdynes, P=0.41), but clot elastic modulus was dynamically altered, resulting in a lower final value (22.9 vs. 17.3 kdynes/cm, Pshock, platelet function was preserved, whereas terminal clot elastic modulus was reduced during shock in a manner most consistent with early changes in the mechanical properties of the developing fibrin fiber network.

  3. Endogenous fibrinolysis facilitates clot retraction in vivo.

    Science.gov (United States)

    Samson, Andre L; Alwis, Imala; Maclean, Jessica A A; Priyananda, Pramith; Hawkett, Brian; Schoenwaelder, Simone M; Jackson, Shaun P

    2017-12-07

    Clot retraction refers to the process whereby activated platelets transduce contractile forces onto the fibrin network of a thrombus, which over time increases clot density and decreases clot size. This process is considered important for promoting clot stability and maintaining blood vessel patency. Insights into the mechanisms regulating clot retraction at sites of vascular injury have been hampered by a paucity of in vivo experimental models. By pairing localized vascular injury with thrombin microinjection in the mesenteric circulation of mice, we have demonstrated that the fibrin network of thrombi progressively compacts over a 2-hour period. This was a genuine retraction process, as treating thrombi with blebbistatin to inhibit myosin IIa-mediated platelet contractility prevented shrinkage of the fibrin network. Real-time confocal analysis of fibrinolysis after recombinant tissue-type plasminogen activator (tPA) administration revealed that incomplete proteolysis of fibrin polymers markedly facilitated clot retraction. Similarly, inhibiting endogenous fibrinolysis with tranexamic acid reduced retraction of fibrin polymers in vivo. In vitro clot retraction experiments indicated that subthreshold doses of tPA facilitated clot retraction through a plasmin-dependent mechanism. These effects correlated with changes in the elastic modulus of fibrin clots. These findings define the endogenous fibrinolytic system as an important regulator of clot retraction, and show that promoting clot retraction is a novel and complementary means by which fibrinolytic enzymes can reduce thrombus size. © 2017 by The American Society of Hematology.

  4. Intracranial hemorrhage: principles of CT and MRI interpretation

    International Nuclear Information System (INIS)

    Parizel, P.M.; Makkat, S.; Miert, E. van; Goethem, J.W. van; Hauwe, L. van den; Schepper, A.M. de

    2001-01-01

    Accurate diagnosis of intracranial hemorrhage represents a frequent challenge for the practicing radiologist. The purpose of this article is to provide the reader with a synoptic overview of the imaging characteristics of intracranial hemorrhage, using text, tables, and figures to illustrate time-dependent changes. We examine the underlying physical, biological, and biochemical factors of evolving hematoma and correlate them with the aspect on cross-sectional imaging techniques. On CT scanning, the appearance of intracranial blood is determined by density changes which occur over time, reflecting clot formation, clot retraction, clot lysis and, eventually, tissue loss. However, MRI has become the technique of choice for assessing the age of an intracranial hemorrhage. On MRI the signal intensity of intracranial hemorrhage is much more complex and is influenced by multiple variables including: (a) age, location, and size of the lesion; (b) technical factors (e.g., sequence type and parameters, field strength); and (c) biological factors (e.g., pO2, arterial vs venous origin, tissue pH, protein concentration, presence of a blood-brain barrier, condition of the patient). We discuss the intrinsic magnetic properties of sequential hemoglobin degradation products. The differences in evolution between extra- and intracerebral hemorrhages are addressed and illustrated. (orig.)

  5. A constitutive model for developing blood clots with various compositions and their nonlinear viscoelastic behavior.

    Science.gov (United States)

    van Kempen, Thomas H S; Donders, Wouter P; van de Vosse, Frans N; Peters, Gerrit W M

    2016-04-01

    The mechanical properties determine to a large extent the functioning of a blood clot. These properties depend on the composition of the clot and have been related to many diseases. However, the various involved components and their complex interactions make it difficult at this stage to fully understand and predict properties as a function of the components. Therefore, in this study, a constitutive model is developed that describes the viscoelastic behavior of blood clots with various compositions. Hereto, clots are formed from whole blood, platelet-rich plasma and platelet-poor plasma to study the influence of red blood cells, platelets and fibrin, respectively. Rheological experiments are performed to probe the mechanical behavior of the clots during their formation. The nonlinear viscoelastic behavior of the mature clots is characterized using a large amplitude oscillatory shear deformation. The model is based on a generalized Maxwell model that accurately describes the results for the different rheological experiments by making the moduli and viscosities a function of time and the past and current deformation. Using the same model with different parameter values enables a description of clots with different compositions. A sensitivity analysis is applied to study the influence of parameter variations on the model output. The relative simplicity and flexibility make the model suitable for numerical simulations of blood clots and other materials showing similar behavior.

  6. Blood Clots

    Science.gov (United States)

    ... sitting for long periods. If you travel by airplane, walk the aisle periodically. For long car trips, ... Your-Risk-for-Excessive-Blood-Clotting_UCM_448771_Article.jsp. Accessed April 18, 2016. What causes excessive ...

  7. Ultrastructure of clots during isometric contraction

    OpenAIRE

    1982-01-01

    We explored the retraction or contraction of platelet-fibrin clots under isometric conditions. In the presence of micromolar calcium clots of normal platelet-rich plasma developed tension at an initial rate of 0.1 to 0.2 g/min per cm2 (initial cross-sectional area). Electron microscopy of clots fixed after attaining a force of 1.6 g/cm2 revealed platelets with elongated bodies and pseudopods in close apposition to fibrin strands which were oriented in cablelike fashion in the direction of ten...

  8. Blood Clots

    Science.gov (United States)

    ... Pregnancy Immobility (including prolonged inactivity, long trips by plane or car ) Smoking Oral contraceptives Certain cancers Trauma Certain surgeries Age (increased risk for people over age 60) A family history of blood clots Chronic inflammatory diseases Diabetes High ...

  9. Pilot study of Alteplase (tissue plasminogen activator) for treatment of urinary clot retention in an in vitro model.

    Science.gov (United States)

    Ritch, Chad R; Ordonez, Maria A; Okhunov, Zhamshid; Araujo, Juan; Walsh, Rhonda; Baudin, Vania; Lee, Daniel; Badani, Ketan K; Gupta, Mantu; Landman, Jaime

    2009-08-01

    The management of urinary clot retention and hematuria involves manual irrigation with sterile water or normal saline via a Foley catheter followed by continuous bladder irrigation. Irrigation may become difficult because of the formation of dense blood clots. Tissue plasminogen activator (t-PA/Alteplase) may be a useful pharmacological agent to improve the efficacy of manual irrigation of large, dense clots. The goal of the current study was to compare t-PA to sterile water for clot irrigation in an in vitro model. In vitro models of clot retention were created using 500-cc urinary leg bags each filled with 80 cc of unpreserved whole blood from a healthy volunteer. Each model was incubated at 25 degrees C for 24 hours to allow clot formation. Four models each with 25 mL solution of t-PA at concentrations of 2, 1, 0.5, and 0.25 mg/mL were evaluated and compared to a control (25 mL sterile water). Models were instilled with solution (t-PA or control) and incubated for 30 minutes at 37 degrees C, and then irrigated with sterile water via 18F Foley by a blinded investigator. Three separate experiments were conducted, and statistical analysis was performed comparing various irrigation parameters. Clot evacuation with 25 mL of t-PA at a concentration of 2 mg/mL (50 mg) was significantly easier (p = 0.05) and faster (p < 0.05) than the sterile water control. The mean time for clot evacuation in this model was 2.7 minutes for t-PA solution 2 mg/mL versus 7.3 minutes for the control (p < 0.05). Compared to the control, irrigation with t-PA solution 2 mg/mL also required less irrigant (180 mL vs. 500 mL) (p < 0.05) for complete evacuation. There was a similar trend in efficacy for the lower doses of t-PA, but this was not statistically significant. In this in vitro study, a single 25 mL instillation of t-PA solution 2 mg/mL is significantly better than sterile water alone for clot evacuation. In vivo animal studies are pending.

  10. CT analysis of intratumoral gas formation after hepatic tumor embolization

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Ahn, In Oak; Kim, Hyung Jin; Lee, Goo; Chung, Sung Hoon

    1994-01-01

    To evaluate the prevalence and the patterns of sterile gas shown at computed tomography(CT) after transarterial embolization(TAE) for primary hepatic tumor. Among 102 patients who performed TAE for hepatoma, thirty-four in whom follow-up CT was underwent constituted the basis of our study. At CT, we evaluated the patterns and locations of intratumoral gas. We also reviewed the clinical data to exclude an infectious origin of intratumoral gas. Of 34 patients, intratumoral gas was detected in 11 patients(32%), in all of whom Gelfoam was used as an embolic material. The initial tumor size measured at pre-TAE CT was larger in patients with intratumoral gas than in patients without it(p < 0.005). No specific patterns or locations of intratumoral gas were noted on CT scans. No patients had clinical signs and symptoms that suggested infection. Intratumoral gas formation without clinical evidence of infection is not an infrequent finding after TAE for hepatoma, especially when Gelfoam is used and when the tumor is larger in size. This finding may be a part of postinfarction syndrome and should not be misinterpreted as an postprocedural abscess formation

  11. Two cases of subdural hematoma with niveau formation on CT

    International Nuclear Information System (INIS)

    Shimizu, Satoshi; Fukuda, Atsuhiro; Sato, Masaharu; Kohama, Akitsugu

    1984-01-01

    The authors report a case of a bilateral chronic subdural hematoma with niveau formation and another rare case of an acute subdural hematoma with niveau formation on plain CT. The different mechanisms of the niveau formation in these cases are speculated about. The first case was a 75-year-old male who showed a drowsy state, urinary incontinence, and muscle weakness of the bilateral lower limbs. No definite history of head trauma could be found. A plain CT scan showed a bilateral-crescent type fluid collection with niveau formation, consisting of a low-density area in the upper part and a high-density area in the lower part. An operation showed bilateral, moderately encapsulated subdural hematomas; they were evacuated. The second case was a 61-year-old male with head trauma due to a fall from a ladder. On admission, neurological examination revealed a decerebrate posture, a deep coma, and anisocoria. A plain CT scan twenty hours after the onset showed a crescent-type fluid collection with niveau formation in the left fronto-parietal region. The operation showed an acute subdural hematoma containing xanthochromic fluid and coagulated blood. No capsule of hematoma could be seen. The incidence of niveau formation in chronic subdural hematomas is not low (5 - 20%); such niveau formation is thought to be caused by rebleeding into the hematoma and the spending of considerable time in the supine position. On the other hand, no case of an acute subdural hematoma with niveau formation has previously been reported. With regard to this mechanism of niveau formation, we speculate that the hematoma is mixed with cerebrospinal fluid from the arachnoidal tear caused by the head trauma; also, a considerable time in the supine position is necessary. (author)

  12. Developing Mesoscale Model of Fibrin-Platelet Network Representing Blood Clotting =

    Science.gov (United States)

    Sun, Yueyi; Nikolov, Svetoslav; Bowie, Sam; Alexeev, Alexander; Lam, Wilbur; Myers, David

    Blood clotting disorders which prevent the body's natural ability to achieve hemostasis can lead to a variety of life threatening conditions such as, excessive bleeding, stroke, or heart attack. Treatment of these disorders is highly dependent on understanding the underlying physics behind the clotting process. Since clotting is a highly complex multi scale mechanism developing a fully atomistic model is currently not possible. We develop a mesoscale model based on dissipative particle dynamics (DPD) to gain fundamental understanding of the underlying principles controlling the clotting process. In our study, we examine experimental data on clot contraction using stacks of confocal microscopy images to estimate the crosslink density in the fibrin networks and platelet location. Using this data we reconstruct the platelet rich fibrin network and study how platelet-fibrin interactions affect clotting. Furthermore, we probe how different system parameters affect clot contraction. ANSF CAREER Award DMR-1255288.

  13. Clot friction variation with fibrin content; implications for resistance to thrombectomy.

    Science.gov (United States)

    Gunning, Gillian M; McArdle, Kevin; Mirza, Mahmood; Duffy, Sharon; Gilvarry, Michael; Brouwer, Patrick A

    2018-01-01

    Despite significant advancements in the procedural efficacy of mechanical thrombectomy in patients with ischemic stroke in recent years, there still remains a portion of the population that does not achieve good recanalization. The reasons for this may be varied. We hypothesized that static friction between the clot and the vessel, or catheter wall might contribute to the difficulty in removing the clot. To determine if there is a relationship between clot composition and the resistance to sliding (friction) which might contribute to resistance to clot removal. As clot composition can vary significantly, we investigated five different types of clot in order to measure their respective frictional properties. To do this, a custom-made testing apparatus was created, consisting of various replaceable low-friction surfaces on which the clots could be placed. The surface was then gradually tilted until the clots began to slide; the angle at which this occurred is related to the coefficient of friction of the clots. The experiment was repeated on a bovine aortic surface in order to confirm the results. We found that fibrin-rich clots (friction than clots with a red blood cell content >20%. This result was confirmed by repeating the experiment on a bovine aortic surface as a representation of the interaction between clots and the arterial wall. The friction properties of clots were found to be related to the content ratio of fibrin to red blood cells. Future imaging techniques that could show fibrin and red blood cell content might help us to predict the 'stickiness' of a clot. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Capture of lipopolysaccharide (endotoxin) by the blood clot: a comparative study.

    Science.gov (United States)

    Armstrong, Margaret T; Rickles, Frederick R; Armstrong, Peter B

    2013-01-01

    In vertebrates and arthropods, blood clotting involves the establishment of a plug of aggregated thrombocytes (the cellular clot) and an extracellular fibrillar clot formed by the polymerization of the structural protein of the clot, which is fibrin in mammals, plasma lipoprotein in crustaceans, and coagulin in the horseshoe crab, Limulus polyphemus. Both elements of the clot function to staunch bleeding. Additionally, the extracellular clot functions as an agent of the innate immune system by providing a passive anti-microbial barrier and microbial entrapment device, which functions directly at the site of wounds to the integument. Here we show that, in addition to these passive functions in immunity, the plasma lipoprotein clot of lobster, the coagulin clot of Limulus, and both the platelet thrombus and the fibrin clot of mammals (human, mouse) operate to capture lipopolysaccharide (LPS, endotoxin). The lipid A core of LPS is the principal agent of gram-negative septicemia, which is responsible for more than 100,000 human deaths annually in the United States and is similarly toxic to arthropods. Quantification using the Limulus Amebocyte Lysate (LAL) test shows that clots capture significant quantities of LPS and fluorescent-labeled LPS can be seen by microscopy to decorate the clot fibrils. Thrombi generated in the living mouse accumulate LPS in vivo. It is suggested that capture of LPS released from gram-negative bacteria entrapped by the blood clot operates to protect against the disease that might be caused by its systemic dispersal.

  15. Capture of lipopolysaccharide (endotoxin by the blood clot: a comparative study.

    Directory of Open Access Journals (Sweden)

    Margaret T Armstrong

    Full Text Available In vertebrates and arthropods, blood clotting involves the establishment of a plug of aggregated thrombocytes (the cellular clot and an extracellular fibrillar clot formed by the polymerization of the structural protein of the clot, which is fibrin in mammals, plasma lipoprotein in crustaceans, and coagulin in the horseshoe crab, Limulus polyphemus. Both elements of the clot function to staunch bleeding. Additionally, the extracellular clot functions as an agent of the innate immune system by providing a passive anti-microbial barrier and microbial entrapment device, which functions directly at the site of wounds to the integument. Here we show that, in addition to these passive functions in immunity, the plasma lipoprotein clot of lobster, the coagulin clot of Limulus, and both the platelet thrombus and the fibrin clot of mammals (human, mouse operate to capture lipopolysaccharide (LPS, endotoxin. The lipid A core of LPS is the principal agent of gram-negative septicemia, which is responsible for more than 100,000 human deaths annually in the United States and is similarly toxic to arthropods. Quantification using the Limulus Amebocyte Lysate (LAL test shows that clots capture significant quantities of LPS and fluorescent-labeled LPS can be seen by microscopy to decorate the clot fibrils. Thrombi generated in the living mouse accumulate LPS in vivo. It is suggested that capture of LPS released from gram-negative bacteria entrapped by the blood clot operates to protect against the disease that might be caused by its systemic dispersal.

  16. Postpartum Blood Clots

    Science.gov (United States)

    ... Video) Fetal Ultrasound Scanning Additional Content Medical News Postpartum Blood Clots By Julie S. Moldenhauer, MD, Associate Professor ... Professional Version Postdelivery Period Overview of the Postdelivery (Postpartum) Period Postpartum Infections Postpartum Infections of the Uterus ...

  17. Characterisation of clotting factors, anticoagulant protein activities and viscoelastic analysis in healthy donkeys.

    Science.gov (United States)

    Perez-Ecija, A; Mendoza, F J

    2017-11-01

    Studies have demonstrated differences in commonly measured haemostatic parameters between donkeys and horses. Whether clotting factors, anticoagulant protein activities and thromboelastography parameters also differ between species is still unknown. To characterise haemostatic parameters in healthy donkeys and to compare these with those in horses. Cross-sectional study. Clotting factors (V, VII, VIII, IX, X, XI and XII), and antithrombin III, Protein C and Protein S activities were measured in 80 healthy Andalusian and crossbred donkeys and 40 healthy Andalusian crossbred horses with assays based on human deficient plasmas. Thromboelastography was performed in 34 donkeys using a coagulation and platelet function analyser. Donkeys had shorter activated partial thromboplastin time (mean ± s.d. 33.4 ± 5.2 s vs. 38.8 ± 4.2 s; P0.05) and XII (96 ± 21 vs. 108 ± 15; Pdonkeys. Activated clot time (175 [159-189]), time to peak (6.5 [5.8-7.8]) and clot formation rate (26.9 [16.9-36.4]) in donkeys were shorter than reported values in horses. Haemostatic pathways could not be fully evaluated in donkeys because some tests are unavailable. Certain fibrinolytic parameters (plasmin, plasminogen, etc.) have not been characterised in donkeys and this may have affected our results. The haemostatic system in donkeys differs from that in horses and extrapolation of reference values between these species is not appropriate. © 2017 EVJ Ltd.

  18. Intracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot: Case Report.

    Science.gov (United States)

    Hwang, Sung Ha; Yoo, Chungkwon; Kim, Yong Yeon; Lee, Dae Young; Nam, Dong Heun; Lee, Jong Yeon

    2017-12-01

    Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by blood clot. The first case was a 57-year-old female suffering from ocular pain because of a tube obstruction with blood clot after AGV implantation in neovascular glaucoma. Surgical blood clot removal was performed. However, intractable bleeding was noted during the removal of the blood clot, and so intracameral air injection was performed to prevent a recurrent tube obstruction. After the procedure, although blood clots formed around the tube, the tube opening where air could touch remained patent. In 3 cases of neovascular glaucoma with preoperative severe intraocular hemorrhages, intracameral air injection and AGV implantation were performed simultaneously. In all 3 cases, tube openings were patent. It appears that air impeded the blood clots formation in front of the tube opening. Intracameral air injection could be a feasible option to prevent tube obstruction of AGV implant with a blood clot in neovascular glaucoma with high risk of tube obstruction. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  19. Investigation of the effect of kaolin and tissue factor-activated citrated whole blood, on clot forming variables, as evaluated by thromboelastograph

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Bochsen, L.; Andersen, S.

    2008-01-01

    ), and maximum clot strength (amplitude [MA]) were evaluated, together with day-to-day variation, the coefficient of variance (CV%), and the effect of citrate storage time. RESULTS: Clot formation variables were equally affected by TF 1:17,000 and kaolin activation, whereas R was significantly longer when TF 1......:42,500 was used. The CV for the different variables varied from 3 to 13 percent with no significant differences between assays. Storage of citrated WB significantly affected the TEG variables in a hypercoagulable direction. Only the R, however, was significantly affected (12%) when samples rested for 0 and 30...... minutes were evaluated with kaolin as the activator. CONCLUSION: The TEG assays evaluated were reproducible and present with an acceptable CV% for routine clinical practice. Kaolin and TF 1:17,000 equally affected the clot formation variables. Storage of WB for up to 30 minutes in citrate did not, except...

  20. Elevated NT-proBNP is associated with unfavorably altered plasma fibrin clot properties in atrial fibrillation.

    Science.gov (United States)

    Matusik, Paweł T; Matusik, Patrycja S; Kornacewicz-Jach, Zdzisława; Małecka, Barbara; Ząbek, Andrzej; Undas, Anetta

    2017-09-15

    Dense fibrin clot formation and hypofibrinolysis have been reported in atrial fibrillation (AF). It is unclear which factors affect fibrin clot properties in AF. We investigated plasma fibrin clot permeability (K s ), clot lysis time (CLT), endogenous thrombin potential (ETP) as well as other coagulation and fibrinolysis parameters along with N-terminal pro-B-type natriuretic peptide (NT-proBNP) in 160 AF patients (median age, 70.5years). Previous stroke (n=15; 9.4%) was associated with decreased K s (P=0.04) and longer CLT (P=0.005), together with higher antiplasmin (P=0.03) and lower tissue-type plasminogen activator (P=0.01). Lower K s (P=0.04) and tendency towards longer CLT (P=0.10) were observed in patients with a left atrium diameter>40mm. Patients with a CHA 2 DS 2 -VASc score of 3 or more (82.5%) were characterized by higher thrombin-activatable fibrinolysis inhibitor antigen (P=0.009). K s was inversely correlated with log NT-proBNP (r=-0.34, PCLT was positively correlated with log NT-proBNP (R=0.61, PCLT (the top quartile,≥109min). In AF patients prothrombotic fibrin clot properties assessed ex vivo are determined by PAI-1 and NT-proBNP and this phenotype is associated with prior ischemic stroke. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A targeted ferritin-microplasmin based thrombolytic nanocage selectively dissolves blood clots.

    Science.gov (United States)

    Seo, Junyoung; Al-Hilal, Taslim A; Jee, Jun-Goo; Kim, Yong-Lim; Kim, Ha-Jeong; Lee, Byung-Heon; Kim, Soyoun; Kim, In-San

    2018-04-01

    The use of thrombolytic therapies is limited by an increased risk of systemic hemorrhage due to lysis of hemostatic clots. We sought to develop a plasmin-based thrombolytic nanocage that efficiently dissolves the clot without causing systemic fibrinolysis or disrupting hemostatic clots. Here, we generated a double chambered short-length ferritin (sFt) construct that has an N-terminal region fused to multivalent clot targeting peptides (CLT: CNAGESSKNC) and a C-terminal end fused to a microplasmin (μPn); CLT recognizes fibrin-fibronectin complexes in clots, μPn efficiently dissolves clots, and the assembly of double chambered sFt (CLT-sFt-μPn) into nanocage structure protects the activated-μPn from its circulating inhibitors. Importantly, activated CLT-sFt-μPn thrombolytic nanocage showed a prolonged circulatory life over activated-μPn and efficiently lysed the preexisting clots in both arterial and venous thromboses models. Thus, CLT-sFt-μPn thrombolytic nanocage platform represents the prototype of a targeted clot-busting agent with high efficacy and safety over existing thrombolytic therapies. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Intrinsic clotting factors in dependency of age, sex, body mass index, and oral contraceptives: definition and risk of elevated clotting factor levels.

    Science.gov (United States)

    Luxembourg, Beate; Schmitt, Joern; Humpich, Marek; Glowatzki, Matthias; Seifried, Erhard; Lindhoff-Last, Edelgard

    2009-10-01

    Elevated clotting factors have been demonstrated to be a risk factor for venous thromboembolism (VTE). The aim of our study was to investigate the impact of age, sex, body mass index, and oral contraceptives on the clotting factor activities of factors VIII, IX, XI, and XII and their impact on the cutoff definition and risk of VTE associated with elevated clotting factors. Factor VIII, IX, XI, and XII activities were measured in 499 blood donors and 286 patients with VTE. Age and body mass index predicted significantly and independently the clotting factor activities of factors VIII, IX, and XI, whereas use of oral contraceptives predicted factor IX, XI, and XII levels. Percentiles of clotting factor activities, which are often used for the cutoff definition of elevated clotting factors, varied due to the effect of age, body mass index, and oral contraceptives. The adjusted odds ratios for VTE were 10.3 [95% confidence interval (CI) 5.1-20.7], 6.1 (95% CI 3.1-12.0), and 3.3 (95% CI 1.9-5.8) for elevated factors VIII, IX, and XI, respectively. Furthermore, our study demonstrates for the first time that elevated factor XII is associated with an increased risk of VTE (adjusted odds ratio 2.9, 95% CI 1.6-5.3).

  3. Sucralfate protects blood clots from peptic digestion by gastric juice in vitro.

    Science.gov (United States)

    Nysaeter, Gunnar; Berstad, Arnold

    2006-01-01

    To test in vitro the ability of sucralfate to protect a blood clot from peptic digestion by gastric juice. Blood clots adhering to the bottom of plastic tubes were exposed to native acidic gastric juice or gastric juice to which Al-Mg antacids, sucralfate or alkali had been added. The tubes were tilted regularly at room temperature and clot digestion monitored by measuring the diameters of the clots. After 15 h, the liquids, but not the adherent clots, were poured out and the tubes refilled with native acidic gastric juice. Further clot digestion was measured, as before. Native gastric juice digested the clots completely during approximately 7 h, while in neutralized gastric juice or in gastric juice containing antacids or sucralfate no digestion was seen. In the second experiment, native gastric juice completely digested all remaining clots, except those previously exposed to sucralfate. A dose-response study indicated that gastric juice containing 3% or more of sucralfate had this long-lasting, clot-protective effect. In vitro, sucralfate adheres to and protects blood clots from digestion by gastric juice pepsin. This unique effect of sucralfate may be of clinical relevance in the treatment of bleeding peptic ulcers. Copyright 2006 S. Karger AG, Basel.

  4. Effect of Cold Storage on Shear-induced Platelet Aggregation and Clot Strength

    Science.gov (United States)

    2014-09-01

    hemostasis and are lifesavingwhen transfused to treat thrombocytopenia. In response to vascular injury, platelets adhere, aggregate, and along with fibrin ...Handling Platelet - rich plasma (PRP) was obtained from phlebot- omized blood or AP collection. Blood was drawn in acid cit- rate dextroseYcontaining...aging and senes- cence during storage.35,38 Platelet activation and aggregation lead to clot formation, beginning with the linear polymerization of fibrin

  5. The Effect of a Simulated Commercial Flight Environment with Hypoxia and Low Humidity on Clotting, Platelet, and Endothelial Function in Participants with Type 2 Diabetes – A Cross-over Study

    Directory of Open Access Journals (Sweden)

    Judit Konya

    2018-02-01

    Full Text Available AimsTo determine if clotting, platelet, and endothelial function were affected by simulated short-haul commercial air flight conditions (SF in participants with type 2 diabetes (T2DM compared to controls.Methods10 participants with T2DM (7 females, 3 males and 10 controls (3 females, 7 males completed the study. Participants were randomized to either spend 2 h in an environmental chamber at sea level conditions (temperature: 23°C, oxygen concentration 21%, humidity 45%, or subject to a simulated 2-h simulated flight (SF: temperature: 23°C, oxygen concentration 15%, humidity 15%, and crossed over 7 days later. Main outcome measures: clot formation and clot lysis parameters, functional platelet activation markers, and endothelial function measured by reactive hyperemia index (RHI by EndoPAT and serum microparticles.ResultsComparing baseline with SF conditions, clot maximal absorption was increased in controls (0.375 ± 0.05 vs. 0.39 ± 0.05, p < 0.05 and participants with T2DM (0.378 ± 0.089 vs. 0.397 ± 0.089, p < 0.01, while increased basal platelet activation for both fibrinogen binding and P-selectin expression (p < 0.05 was seen in participants with T2DM. Parameters of clot formation and clot lysis, stimulated platelet function (stimulated platelet response to ADP and sensitivity to prostacyclin, and endothelial function were unchanged.ConclusionWhile SF resulted in the potential of denser clot formation with enhanced basal platelet activation in T2DM, the dynamic clotting, platelet, and endothelial markers were not affected, suggesting that short-haul commercial flying adds no additional hazard for venous thromboembolism for participants with T2DM compared to controls.

  6. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... of articles from the 2017 ASH Annual Meeting Education Program Blood: How I Treat A compendium of Blood articles ... Pregnancy Clots and Travel DVT Myths vs. Facts Blood Disorder Fact Sheets ...

  7. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) Multiple births Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are Blood ...

  8. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... genetic predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) Multiple births Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are ...

  9. Pulmonary embolism: spiral CT evaluation; Embolie pulmonaire: apport de la tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Senac, J.P.; Vernhet, H.; Bousquet, C.; Giron, J.; Pieuchot, P.; Durand, G.; Benezet, O.; Aubas, P. [Centre Hospitalier Universitaire, 34 - Montpellier (France)

    1995-06-01

    Purpose: Spiral computed tomography was compared retrospectively with digital substraction pulmonary angiography (PA) in 45 patients suspected of having acute or chronic pulmonary embolism. Materials and method : 45 patients in whom the presence of acute or chronic pulmonary embolism was suspected underwent examination by spiral CT and PA. Diagnosis of pulmonary embolism was based on the direct visualization of intraluminal clots. The study of the agreement between the two methods was based on the Kappa test. In 35 cases, pulmonary emboli were proved. Acute pulmonary emboli were present in 28 cases and chronic in 7 cases. Results: Spiral computed tomography represents an excellent way to detect acute pulmonary embolism. In the chronic form, spiral CT is better than PA to detect intraluminal clots. However, Spiral CT can fail to detect small emboli in the peripheral arterial bed. In the 10 patients without pulmonary embolism, the spiral CT proved diagnosis pulmonary oedema (n=3), lymphangi-carcinoma (n=4), pleural effusion (n=3). Conclusion: This study suggest that the spiral CT examination is accurate for diagnosis of pulmonary embolism specifically in case of suspected important embolism. The advantages of spiral CT are multiple (non invasive, wide diagnosis spectrum). However, may be a limitation to is use is insufficient distal thrombi detection. This eventuality (5 to 10% in the Pioped study) justify the practice of pulmonary angiography. Spiral CT improvements should reduce this insufficiency in the next future. (Authors). 16 refs., 4 figs., 3 tabs.

  10. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... have one. If you are pregnant and have concerns about blood clots, talk with your doctor about ... 2018 by American Society of Hematology Support Opportunities | Privacy Policy | Terms of Service | Contact Us

  11. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Action on DVT and PE to raise public awareness of these blood conditions and increase research on ... Increased maternal age Other medical illness (e.g., cancer, infection) back to top How are Blood Clots ...

  12. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... A genetic predisposition to blood clots Obesity Prolonged immobility (e.g., bedrest, long distance travel) Multiple births ... treating blood conditions. back to top Antiphospholipid Antibody Syndrome: A Patient's Journey back to top Where Can ...

  13. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... harming your baby. Jump To: Am I at Risk? The risk of developing a blood clot during ... Advances The Hematologist ASH Clinical News ASH Self-Assessment Program Hematology , ASH Education Program About Awards Membership ...

  14. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... known as venous thromboembolism, are highly preventable (see prevention tips below). The U.S. Surgeon General has issued ... blood conditions and increase research on the causes, prevention, and treatment. Blood clots are also potentially dangerous ...

  15. 14-Day thawed plasma retains clot enhancing properties and inhibits tPA-induced fibrinolysis.

    Science.gov (United States)

    Huebner, Benjamin R; Moore, Ernest E; Moore, Hunter B; Shepherd-Singh, Raymond; Sauaia, Angela; Stettler, Gregory R; Nunns, Geoffrey R; Silliman, Christopher C

    2017-11-01

    Plasma-first resuscitation attenuates trauma-induced coagulopathy (TIC); however, the logistics of plasma-first resuscitation require thawed plasma (TP) be readily available due to the obligatory thawing time of fresh frozen plasma (FFP). The current standard is storage of TP for up to 5 days at 4°C, based on factor levels at outdate, for use in patients at risk for TIC, but there remains a 2.2% outdated wastage rate. However, the multitude of plasma proteins in attenuating TIC remains unknown. We hypothesize that TP retains the ability to enhance clotting and reduce tPA-induced fibrinolysis at 14-day storage. FFP was thawed and stored at 4°C at the following intervals: 14, 10, 7, 5, 3, and 1-day prior to the experiment. Healthy volunteers underwent blood draws followed by 50% dilution with TP stored at previously mentioned intervals as well as FFP, normal saline (NS), albumin, and whole blood (WB) control. Samples underwent tPA-modified (75 ng/mL) thrombelastography (TEG) with analysis of R-time, angle, maximum amplitude (MA), and LY30. TEG properties did not change significantly over the thawed storage. 14-day TP retained the ability to inhibit tPA-induced hyperfibrinolysis (median LY30% 9.6%) similar to FFP (5.6%), WB (14.6%), and superior to albumin (59.3%) and NS (58.1%). 14-day TP also retained faster clot formation (median angle, 66.2°) and superior clot strength (MA, 61.5 mm) to albumin (34.8°, 21.6 mm) and NS (41.6°, 32.2 mm). TP plasma stored for 14 days retains clot-enhancing ability and resistance to clot degradation similar to FFP. A clinical trial is needed to validate these in vitro results. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to help stay current with the latest advances in the field Hematology 2017 A collection of articles from ... Blood clots in pregnant women tend to form in the deep veins of the legs or in the ...

  17. Site specific measurements of bone formation using [18F] sodium fluoride PET/CT.

    Science.gov (United States)

    Blake, Glen M; Puri, Tanuj; Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac

    2018-02-01

    Dynamic positron emission tomography (PET) imaging with fluorine-18 labelled sodium fluoride ([ 18 F]NaF) allows the quantitative assessment of regional bone formation by measuring the plasma clearance of fluoride to bone at any site in the skeleton. Today, hybrid PET and computed tomography (CT) dual-modality systems (PET/CT) are widely available, and [ 18 F]NaF PET/CT offers a convenient non-invasive method of studying bone formation at the important osteoporotic fracture sites at the hip and spine, as well as sites of pure cortical or trabecular bone. The technique complements conventional measurements of bone turnover using biochemical markers or bone biopsy as a tool to investigate new therapies for osteoporosis, and has a potential role as an early biomarker of treatment efficacy in clinical trials. This article reviews methods of acquiring and analyzing dynamic [ 18 F]NaF PET/CT scan data, and outlines a simplified approach combining venous blood sampling with a series of short (3- to 5-minute) static PET/CT scans acquired at different bed positions to estimate [ 18 F]NaF plasma clearance at multiple sites in the skeleton with just a single injection of tracer.

  18. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... are pregnant and have concerns about blood clots, talk with your doctor about your risks and prevention. Depending on your condition, your OB-GYN may refer you to a hematologist, a doctor who specializes in treating blood conditions. back to top ...

  19. Investigation of the thrombin-generating capacity, evaluated by thrombogram, and clot formation evaluated by thrombelastography of platelets stored in the blood bank for up to 7 days

    DEFF Research Database (Denmark)

    Johansson, Per Ingemar; Svendsen, M.S.; Salado, J.

    2008-01-01

    thrombin) and endogenous thrombin potential (ETP; nm thrombin*min) were registered. Clot formation was evaluated by TEG and the R time (min), maxial amplitude (MA; mm), time to maximum thrombus generation (TMG; min) and maximum thrombus generation (MTG; dynes cm(-2) s(-1)) and total thrombus generation...... (TTG; dyne cm(-2)) were registered. RESULTS: Platelets become more procoagulant, evaluated both by TEG and CAT during storage. The reduction in CAT lag time and the ttPeak correlated with a decrease in the TEG R time and TMG (P

  20. Hyperplastic callus formation in osteogenesis imperfecta: CT and MRI findings

    International Nuclear Information System (INIS)

    Rieker, O.; Kreitner, K.F.; Karbowski, A.

    1998-01-01

    Hyperplastic callus formation is a noteworthy condition in patients with osteogenesis imperfecta because it often mimicks osteosarcoma on radiography. The findings of CT and MRI in hyperplastic callus formation have not been reported. In the presented case, MRI demonstrated contrast enhancement and edema of the surrounding soft tisssue, consistent with benign as well as malignant disease. Computed tomography showed a calcified rim of the lesion which may be a useful feature to rule out osteosarcoma in this condition. (orig.)

  1. Identification of quantitative trait loci for fibrin clot phenotypes: the EuroCLOT study

    DEFF Research Database (Denmark)

    Williams, Frances M K; Carter, Angela M; Kato, Bernet

    2009-01-01

    OBJECTIVE: Fibrin makes up the structural basis of an occlusive arterial thrombus, and variability in fibrin phenotype relates to cardiovascular risk. The aims of the current study from the EU consortium EuroCLOT were to (1) determine the heritability of fibrin phenotypes and (2) identify QTLs as...

  2. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  3. The relationship between contrast enhancement on CT and cerebral vasospasm in patient with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Tazawa, Toshiaki; Mizukami, Masahiro; Kawase, Takeshi; Usami, Takashi; Togashi, Osamu

    1982-01-01

    Sixty patients with a single rupture of an aneurysm were subjected to study. Contrast enhanced CT (CECT) was performed by intravenous infusion of 100 ml of 60% meglumine iothalamate in 10 minutes. Post-contrast CT scans were repeated serially just after infusion, 15 minutes and 30 minutes later. Prominent increase in density in the region of the circle of Willis and its branches 30 minutes after infusion was considered as remarkable enhancement. In 17 (46%) out of 37 patients who underwent CECT within day 3, the contrast enhancement was remarkable. Transient or permanent symptomatic vasospasm occurred in 13 (76.5%) out of these 17 patients and the remaining 4 patients who underwent the operation with successful removal of subarachnoid clot within day 3 did not develop symptomatic vasospasm. Eight (67%) out of 12 patients operated within day 3, in whom post-operative CT showed incomplete removal of subarachnoid clot, developed transient or permanent symptomatic vasospasm. In only one (5%) out of 20 patients without remarkable enhancement, transient symptomatic vasospasm occurred. The abnormal contrast enhancement in the region of the circle of Willis and its branches within day 3 was closely related to the subsequent occurrence of vasospasm. Contrast enhanced CT was performed in 41 patients after day 3. There was no patient with remarkable enhancement on CECT. There was no relationship between the findings on CECT after day 3 and the occurrence of vasospasm. CECT within day 3 allows prediction of that patient destined for vasospasm and early removal of subarachnoid clot within day 3 may minimize the future development of vasospasm.(J.P.N.)

  4. Hyperplastic callus formation in osteogenesis imperfecta: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Rieker, O.; Kreitner, K.F. [Klinik fuer Radiologie, Johannes-Gutenberg-Univ. Mainz (Germany); Karbowski, A. [Orthopaedische Abtl., Krankenhaus der Augustinerinnen, Koeln (Germany)

    1998-09-01

    Hyperplastic callus formation is a noteworthy condition in patients with osteogenesis imperfecta because it often mimicks osteosarcoma on radiography. The findings of CT and MRI in hyperplastic callus formation have not been reported. In the presented case, MRI demonstrated contrast enhancement and edema of the surrounding soft tisssue, consistent with benign as well as malignant disease. Computed tomography showed a calcified rim of the lesion which may be a useful feature to rule out osteosarcoma in this condition. (orig.) With 2 figs., 18 refs.

  5. Effect of anticoagulant administration on blood clotting and some hormones related to rat-fertility

    International Nuclear Information System (INIS)

    Abdel-Khalek, L.G.

    2009-01-01

    This study was performed using 30 mature male albino rats divided into 3 equal groups; control and two treated groups to assess the effect of anticoagulant (warfarin) administration on the level of some hormones related to fertility. The two treated groups were injected intraperitoneally every other day with 1 ml (0.03 mg)and 2 ml (0.06 mg)warfarin/ 100 g body weight respectively where, two specimens were taken from each group after two and four weeks. Clotting time (CT), prothrombin time (PT), partial prothrombin time (PTT) platelets count, fasting blood sugar (F.B.S), calcium levels in addition to triiodothyronine (T 3 ), thyroxin (T 4 ), insulin, corticosterone, and testosterone hormones were determined. The results showed that the intraperitoneal injection of warfarin caused significant increase in clotting time, prothrombin time , partial prothrombin time, platelets count and glucose level, while serum calcium level showed significant decrease. Intraperitoneal injection of warfarin caused significant decrease of insulin and significant increase of corticosterone, T 3 showed significant decrease in high dose group while T 4 showed significant decrease in small dose group. The high dose was associated with the highest level of testosterone hormone. these results denoted that warfarin anticoagulant had no negative effect on gonadal sex hormone and hence on male fertility

  6. Effect of chitosan and coagulation factors on the wound repair phenotype of bioengineered blood clots.

    Science.gov (United States)

    Hoemann, Caroline D; Marchand, Catherine; Rivard, Georges-Etienne; El-Gabalawy, Hani; Poubelle, Patrice E

    2017-11-01

    Controlling the blood clot phenotype in a surgically prepared wound is an evolving concept in scaffold-guided tissue engineering. Here, we investigated the effect of added chitosan (80% or 95% Degree of Deacetylation, DDA) or coagulation factors (recombinant human Factor VIIa, Tissue Factor, thrombin) on inflammatory factors released by blood clots. We tested the hypothesis that 80% DDA chitosan specifically enhances leukotriene B 4 (LTB 4 ) production. Human or rabbit whole blood was combined with isotonic chitosan solutions, coagulation factors, or lipopolysaccharide, cultured in vitro at 37°C, and after 4hours the serum was assayed for LTB 4 or inflammatory factors. Only 80% DDA chitosan clots produced around 15-fold more LTB 4 over other clots including 95% DDA chitosan clots. All serum contained high levels of PDGF-BB and CXCL8. Normal clots produced very low type I cytokines compared to lipopolysaccharide clots, with even lower IL-6 and IL-12 and more CCL3/CCL4 produced by chitosan clots. Coagulation factors had no detectable effect on clot phenotype. Conclusion In blood clots from healthy individuals, 80% DDA chitosan has a unique influence of inducing more LTB 4 , a potent neutrophil chemoattractant, with similar production of PDGF-BB and CXCL8, and lower type I cytokines, compared to whole blood clots. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Origin of opal-ct in lower eocene tallahatta formation, mississippi, usa and pleistocene barind clay formation in bangladesh: A comparative study

    International Nuclear Information System (INIS)

    Kabir, S.

    2008-01-01

    Opal-CT mineral in the lower Eocene Tallahatta formation in Mississippi. USA and the Pleistocene Barind clay formation in Bangladesh is of volcanogenic origin. X-ray diffraction patterns of claystones in the former indicated more ordered condition on the older sediments than those of the latter, which may be due to higher burial temperatures and longer time interval for transformation from volcanic ash to opal-CT of the former. Glass shards, present in the latter sediments, were not identified in the former, which may be due to transformation of glass shards of volcanic ash to opal-Cr over the time. (author)

  8. Addition of a sequence from α2-antiplasmin transforms human serum albumin into a blood clot component that speeds clot lysis

    Directory of Open Access Journals (Sweden)

    Gataiance Sharon

    2009-03-01

    Full Text Available Abstract Background The plasma protein α2-antiplasmin (α2AP is cross-linked to fibrin in blood clots by the transglutaminase factor XIIIa, and in that location retards clot lysis. Competition for this effect could be clinically useful in patients with thrombosis. We hypothesized that fusion of N-terminal portions of α2-antiplasmin to human serum albumin (HSA and production of the chimeric proteins in Pichia pastoris yeast would produce a stable and effective competitor protein. Results Fusion protein α2AP(13-42-HSA was efficiently secreted from transformed yeast and purified preparations contained within a mixed population the full-length intact form, while fusions with longer α2AP moieties were inefficiently secreted and/or degraded. The α2AP(13-42-HSA protein, but not recombinant HSA, was cross-linked to both chemical lysine donors and fibrin or fibrinogen by factor XIIIa, although with less rapid kinetics than native α2AP. Excess α2AP(13-42-HSA competed with α2AP for cross-linking to chemical lysine donors more effectively than a synthetic α2AP(13-42 peptide, and reduced the α2AP-dependent resistance to fibrinolysis of plasma clots equally effectively as the peptide. Native α2AP was found in in vivo clots in rabbits to a greater extent than α2AP(13-42, however. Conclusion In this first report of transfer of transglutamination substrate status from one plasma protein to another, fusion protein α2AP(13-42-HSA was shown to satisfy initial requirements for a long-lasting, well-tolerated competitive inhibitor of α2-antiplasmin predicted to act in a clot-localized manner.

  9. CT findings of osteogenesis imperfecta

    Energy Technology Data Exchange (ETDEWEB)

    Kojo, Nobuto; Otsuru, Katsuyasu; Lee, Soichi; Takagi, Shigeyuki; Shigemori, Minoru.

    1987-08-01

    Two cases of osteogenesis imperfecta found in one family (father and daughter) are reported, and the CT findings are described. Case 1 is a 58-year-old man who fell and struck his head at home on November 10, 1984. He was transferred to Omuta City Hospital when he became semicomatose and decerebrate posturing was noted. His family history revealed 8 persons with osteogenesis imperfecta. A skull X-ray film showed a large skull vault, many wormian bones at the lambdoid suture, platybasia, and a basilar impression. A CT scan demonstrated a right acute subdural hematoma, while the bone image showed well-developed mastoid air cells and a skull deformity characteristic of osteogenesis imperfecta. He had an emergency operation, and a 170-gr clot was successfully evacuated. A postoperative CT scan demonstrated brain atrophy, possibly present before head trauma. Case 2 is the daughter of Case 1 (a 27-year-old woman). She also showed characteristic neuroradiological manifestations on a plain skull film and on a CT scan. A basilar impression and platybasia were also demonstrated. In this report, the possible mechanism of the production of a traumatic acute subdural hematoma is also discussed.

  10. CT findings of osteogenesis imperfecta

    International Nuclear Information System (INIS)

    Kojo, Nobuto; Otsuru, Katsuyasu; Lee, Soichi; Takagi, Shigeyuki; Shigemori, Minoru.

    1987-01-01

    Two cases of osteogenesis imperfecta found in one family (father and daughter) are reported, and the CT findings are described. Case 1 is a 58-year-old man who fell and struck his head at home on November 10, 1984. He was transferred to Omuta City Hospital when he became semicomatose and decerebrate posturing was noted. His family history revealed 8 persons with osteogenesis imperfecta. A skull X-ray film showed a large skull vault, many wormian bones at the lambdoid suture, platybasia, and a basilar impression. A CT scan demonstrated a right acute subdural hematoma, while the bone image showed well-developed mastoid air cells and a skull deformity characteristic of osteogenesis imperfecta. He had an emergency operation, and a 170-gr clot was successfully evacuated. A postoperative CT scan demonstrated brain atrophy, possibly present before head trauma. Case 2 is the daughter of Case 1 (a 27-year-old woman). She also showed characteristic neuroradiological manifestations on a plain skull film and on a CT scan. A basilar impression and platybasia were also demonstrated. In this report, the possible mechanism of the production of a traumatic acute subdural hematoma is also discussed. (author)

  11. A French National Survey on Clotting Disorders in Mastocytosis.

    Science.gov (United States)

    Carvalhosa, Ana B; Aouba, Achille; Damaj, Gandhi; Canioni, Danielle; Brouzes, Chantal; Gyan, Emmanuel; Durupt, Stéphane; Durieu, Isabelle; Cathebras, Pascal; Costédoat-Chalumeau, Nathalie; Launay, David; Pilmis, Benoit; Barete, Stephane; Frenzel, Laurent; Lortholary, Olivier; Hermine, Olivier; Hermans, Cedric; Chandesris, Marie-Olivia

    2015-10-01

    Mastocytosis is characterized by a clonal mast cell proliferation with organ infiltration and uncontrolled degranulation. Although not characteristic and poorly explained, some patients develop clotting abnormalities. We retrospectively identified patients with established diagnosis of mastocytosis and related clotting abnormalities (clinical and/or biological) using the national French Reference Centre for Mastocytosis database. From our cohort of 14 adult patients with clotting abnormalities (median age 46 years [range 26-75]), 4 had a presentation suggestive of a primary hemostasis disorder alone (by their symptoms and/or abnormal clotting tests [PFA, von Willebrand's disease [vWD] screening]) and 10 had a laboratory impairment of secondary hemostasis. Among these, 7 had bleeds characteristic of a coagulation cascade disorder (severe/life-threatening in 5 and mild in 2 patients). Clotting abnormalities were of variable severity, typically related to intense crisis of degranulation, such as anaphylactic reactions, and/or to severe organ infiltration by mast cells. Importantly, classical hemostatic management with platelet transfusion, fresh frozen plasma, or vitamin K infusions was unsuccessful, as opposed to the use of agents inhibiting mast cell activity, particularly steroids. This illustrates the crucial role of mast cell mediators such as tryptase and heparin, which interfere both with primary (mainly via inhibition of von Willebrand factor) and secondary hemostasis. There was interestingly an unusually high number of aggressive mastocytosis (particularly mast cell leukemia) and increased mortality in the group with secondary hemostasis disorders (n = 5, 36% of the whole cohort). Mast cell degranulation and/or high tumoral burden induce both specific biologic antiaggregant and anticoagulant states with a wide clinical spectrum ranging from asymptomatic to life-threatening bleeds. Hemostatic control is achieved by mast cell inhibitors such as steroids.

  12. Evaluation of bone formation in calcium phosphate scaffolds with μCT-method validation using SEM.

    Science.gov (United States)

    Lewin, S; Barba, A; Persson, C; Franch, J; Ginebra, M-P; Öhman-Mägi, C

    2017-10-05

    There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in

  13. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  14. Some Important Milestones in the Field of Blood Clotting.

    Science.gov (United States)

    Doolittle, Russell F

    2016-01-01

    Several different kinds of 'milestone' in the field of blood coagulation are described from the middle decades of the 20th century. Although viewed from the standpoint of clotting per se, attention is also given to implications for innate immunity. The first milestone considered is the protracted saga of clotting dependence on vitamin K, an adventure that spanned more than five decades beginning in the 1920s. The second has to do with the discovery of a half-dozen 'new' clotting factors during the period immediately following World War II. A third pursues a narrower focus and examines the once mysterious transformation of fibrinogen into fibrin. Finally, the clinical treatment of classical hemophilia had a remarkable turning point in the 1960s as the result of simple but sensible measures. © 2015 S. Karger AG, Basel.

  15. Clotting of mammalian fibrinogens by papain: A re-examination

    OpenAIRE

    Doolittle, RF

    2014-01-01

    © 2014 American Chemical Society. Papain has long been known to cause the gelation of mammalian fibrinogens. It has also been reported that papain-fibrin is insoluble in dispersing solvents like strong urea or sodium bromide solutions, similar to what is observed with thrombin-generated clots in the presence of factor XIIIa and calcium. In those old studies, both the gelation and subsequent clot stabilization were attributed to papain, although the possibility that the second step might be du...

  16. Reduced clot debris size using standing waves formed via high intensity focused ultrasound

    Science.gov (United States)

    Guo, Shifang; Du, Xuan; Wang, Xin; Lu, Shukuan; Shi, Aiwei; Xu, Shanshan; Bouakaz, Ayache; Wan, Mingxi

    2017-09-01

    The feasibility of utilizing high intensity focused ultrasound (HIFU) to induce thrombolysis has been demonstrated previously. However, clinical concerns still remain related to the clot debris produced via fragmentation of the original clot potentially being too large and hence occluding downstream vessels, causing hazardous emboli. This study investigates the use of standing wave fields formed via HIFU to disintegrate the thrombus while achieving a reduced clot debris size in vitro. The results showed that the average diameter of the clot debris calculated by volume percentage was smaller in the standing wave mode than in the travelling wave mode at identical ultrasound thrombolysis settings. Furthermore, the inertial cavitation dose was shown to be lower in the standing wave mode, while the estimated cavitation bubble size distribution was similar in both modes. These results show that a reduction of the clot debris size with standing waves may be attributed to the particle trapping of the acoustic potential well which contributed to particle fragmentation.

  17. Pro blood clotting activity of Scoparia dulcis in rats.

    Science.gov (United States)

    Ediriweera, E R H S S; Jayakody, J R A C; Ratnasooriya, W D

    2011-04-01

    Scoparia dulcis Linn (Family: Scrophulariaceae, Sinhala: WalKoththamalli) is a perennial herb growing in many tropical countries including Sri Lanka. Traditional Physicians in rural down south areas apply crushed S. dulcis plant on cuts and bruises to stop bleeding. S. dulcis may also have Rakta Sthambhana property. The study on effect of decoction (water extract) of S. dulcis on blood clotting time in rats was carried out to investigate this. Two groups of rats, 12 males and 42 females were used in this experimental study. Forty-two female rats were assigned into seven equal groups (n = 6/gp). Different doses of DE (25, 50, 100, 1000, 1500 mg/kg) (group 1-5) or 2 ml of distilled water (DW) (group 6) were orally administered. 0.1 ml of vitamin K was injected intramuscularly (group 7) as reference drug to seventh the group. Twelve male rats were assigned into two equal groups (n = 6/gp), 2 ml of distilled water (DW) and doses of DE (1500 mg/kg) were orally administered. Clotting time was determined on the Days 1, 2, and 7 using Lee and White method. In the DE treated groups with all doses, there was no reduction in clotting time on the Day 1 but a significant reduction of clotting time (P dulcis has proclotting activity (rakthasthambhana property) and this was faster than vitamin K.

  18. Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

    Science.gov (United States)

    Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong

    2013-01-01

    Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583

  19. Non-severe pulmonary embolism: Prognostic CT findings

    International Nuclear Information System (INIS)

    Moroni, Anne-Line; Bosson, Jean-Luc; Hohn, Noelie; Carpentier, Francoise; Pernod, Gilles; Ferretti, Gilbert R.

    2011-01-01

    The goal of this study was to retrospectively evaluate CT cardiovascular parameters and pulmonary artery clot load score as predictors of 3-month mortality in patients with clinically non-severe pulmonary embolism (PE). We included 226 CT positive for PE in hemodynamically stable patients (112 women; mean age 67.1 years ±16.9). CT were independently reviewed by two observers. Results were compared with occurrence of death within 3 months using Cox regression. Twenty-four (10.6%) patients died, for whom 9 were considered to be due to PE. Interobserver agreement was moderate for the shape of interventricular septum (κ = 0.41), and for the ratio between the diameters of right and left ventricle (RV/LV) (κ = 0.76). Observers found no association between interventricular septum shape and death. A RV/LV diameter ratio >1 was predictive of death (OR, 3.83; p 1 is predictive of death when the embolic burden is low (<40%).

  20. Simulation of the radiography formation process from CT patient volume

    International Nuclear Information System (INIS)

    Bifulco, P.; Cesarelli, M.; Verso, E.; Roccasalva Firenze, M.; Sansone, M.; Bracale, M.

    1998-01-01

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors)

  1. Artificial Stroke Clots: How Wide is the Gap to the Real World?

    Science.gov (United States)

    Berndt, Maria; Prothmann, Sascha; Maegerlein, Christian; Oberdieck, Paul; Zimmer, Claus; Hegge, Barbara; Pelisek, Jaroslav; Schirmer, Lucas; Poppert, Holger; Boeckh-Behrens, Tobias

    2018-02-01

    Especially since the establishment of mechanical thrombectomy as part of standard stroke therapy, artificial thrombi have become important in the training of interventionalists as well as for the development and testing of devices. So far, these in vitro clots have lacked direct comparisons with ex vivo thrombi. We therefore compared the histologic appearance of dynamically produced clots with that of stroke thrombi acquired during mechanical recanalization. Thrombi of 145 consecutive patients with stroke with large-vessel occlusions were histologically compared with 10 artificial clots, dynamically created from human blood and pig's blood using a Chandler loop system. Quantified FP/RBC ratios (fibrin/platelets divided by red blood cell fraction) and white blood cell (WBC) fractions were identified and compared between artificial (human and pig) and ex vivo thrombi obtained from patients with various stroke causes. There were no significant differences in the analysis of FP/RBC ratios between artificial thrombi and ex vivo thrombi (P = 0.42) or in the more precise analyses considering etiologic subgroups. Distinct differences were observed for the WBC fraction, with lower values in artificial thrombi (median, 1.34%) than in ex vivo thrombi (median, 5%) (P < 0.001). The main clot components, FP and RBC, are presumably the most influential factors for clot stability and mechanical resistance. Similarities between artificially generated and ex vivo stroke clots (and when considering different stroke subgroups) support the usefulness of these artificial thrombi in the pre-evaluation of thrombus extraction devices and as appropriate training material. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. 42 CFR 410.63 - Hepatitis B vaccine and blood clotting factors: Conditions.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Hepatitis B vaccine and blood clotting factors... Other Health Services § 410.63 Hepatitis B vaccine and blood clotting factors: Conditions... under § 410.10, subject to the specified conditions: (a) Hepatitis B vaccine: Conditions. Effective...

  3. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  4. Identification and characterization of milk-clotting proteases ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... Two strains of fungi were isolated and identified as Aspergillus tamarii and Penicillium pinophilum ... for milk clotting enzymes by fermentation at acid pH on culture medium containing whey ..... Rhizopus oryzae NBRC 4749.

  5. Simulation of the radiography formation process from CT patient volume

    Energy Technology Data Exchange (ETDEWEB)

    Bifulco, P; Cesarelli, M; Verso, E; Roccasalva Firenze, M; Sansone, M; Bracale, M [University of Naples, Federico II, Electronic Engineering Department, Bioengineering Unit, Via Claudio, 21 - 80125 Naples (Italy)

    1999-12-31

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors) 16 refs., 12 figs., 1 tabs.

  6. CT diagnosis of intraperitoneal bladder rupture with blunt abdominal trauma

    International Nuclear Information System (INIS)

    Kong Fanbin

    2000-01-01

    Objective: To evaluate CT examination in the diagnosis of intraperitoneal bladder rupture (IPBR) caused by blunt abdominal trauma. Methods: All CT and clinical data of 9 patients with IPBR were reviewed retrospectively. Results: IPBR was detected on CT scans in all 9 patients. CT findings of IPBR included low -attenuation free intraperitoneal fluid collections in the lateral paravesical fossae, the pericolic space, the culde-sac of the pelvis, Morison's pouch, the peri-hepatic space, the perisplenic space and interspace of bowel loops in 9 cases with a lower CT density compared with pure blood. The disruption of the bladder wall was located by CT scan in 5 cases: high-attenuation bladder wall with focal defect in 3 cases and a tear drop-like deformity of the bladder in 2 cases. Other CT findings supporting the diagnosis of IPBR included an underfilled bladder in 8 cases, bladder contusion in 4 cases, and blood clots within the bladder in 6 cases. Conclusion: The presence of intraperitoneal fluid with a CT density less than that of pure blood strongly suggests extravasated urine in the trauma. Intraperitoneal and extraperitoneal rupture can be distinguished based on location of extravasated urine seen on CT scans. The precise localization of the ruptured bladder wall may be demonstrated by CT scan, which is valuable for surgical treatment

  7. Bone formation rather than inflammation reflects Ankylosing Spondylitis activity on PET-CT: a pilot study

    OpenAIRE

    Bruijnen, Stefan TG; van der Weijden, Mignon AC; Klein, Joannes P; Hoekstra, Otto S; Boellaard, Ronald; van Denderen, J Christiaan; Dijkmans, Ben AC; Voskuyl, Alexandre E; van der Horst-Bruinsma, Irene E; van der Laken, Conny J

    2012-01-01

    Introduction Positron Emission Tomography - Computer Tomography (PET-CT) is an interesting imaging technique to visualize Ankylosing Spondylitis (AS) activity using specific PET tracers. Previous studies have shown that the PET tracers [18F]FDG and [11C](R)PK11195 can target inflammation (synovitis) in rheumatoid arthritis (RA) and may therefore be useful in AS. Another interesting tracer for AS is [18F]Fluoride, which targets bone formation. In a pilot setting, the potential of PET-CT in ima...

  8. Prediction of recurrent venous thromboembolism by clot lysis time: a prospective cohort study.

    Science.gov (United States)

    Traby, Ludwig; Kollars, Marietta; Eischer, Lisbeth; Eichinger, Sabine; Kyrle, Paul A

    2012-01-01

    Venous thromboembolism (VTE) is a chronic disease, which tends to recur. Whether an abnormal fibrinolytic system is associated with an increased risk of VTE is unclear. We assessed the relationship between fibrinolytic capacity (reflected by clot lysis time [CLT]) and risk of recurrent VTE. We followed 704 patients (378 women; mean age 48 yrs) with a first unprovoked VTE for an average of 46 months after anticoagulation withdrawal. Patients with natural coagulation inhibitor deficiency, lupus anticoagulant, cancer, homozygosity for factor V Leiden or prothrombin mutation, or requirement for indefinite anticoagulation were excluded. Study endpoint was symptomatic recurrent VTE. For measurement of CLT, a tissue factor-induced clot was lysed by adding tissue-type plasminogen activator. Time between clot formation and lysis was determined by measuring the turbidity. 135 (19%) patients had recurrent VTE. For each increase in CLT of 10 minutes, the crude relative risk (RR) of recurrence was 1.13 (95% CI 1.02-1.25; p = 0.02) and was 1.08 (95% CI 0.98-1.20; p = 0.13) after adjustment for age and sex. For women only, the adjusted RR was 1.14 (95% CI, 0.91-1.42, p = 0.22) for each increase in CLT of 10 minutes. CLT values in the 4(th) quartile of the female patient population, as compared to values in the 1(st) quartile, conferred a risk of recurrence of 3.28 (95% CI, 1.07-10.05; p = 0.04). No association between CLT and recurrence risk was found in men. Hypofibrinolysis as assessed by CLT confers a moderate increase in the risk of recurrent VTE. A weak association between CLT and risk of recurrence was found in women only.

  9. Prediction of recurrent venous thromboembolism by clot lysis time: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    Ludwig Traby

    Full Text Available Venous thromboembolism (VTE is a chronic disease, which tends to recur. Whether an abnormal fibrinolytic system is associated with an increased risk of VTE is unclear. We assessed the relationship between fibrinolytic capacity (reflected by clot lysis time [CLT] and risk of recurrent VTE. We followed 704 patients (378 women; mean age 48 yrs with a first unprovoked VTE for an average of 46 months after anticoagulation withdrawal. Patients with natural coagulation inhibitor deficiency, lupus anticoagulant, cancer, homozygosity for factor V Leiden or prothrombin mutation, or requirement for indefinite anticoagulation were excluded. Study endpoint was symptomatic recurrent VTE. For measurement of CLT, a tissue factor-induced clot was lysed by adding tissue-type plasminogen activator. Time between clot formation and lysis was determined by measuring the turbidity. 135 (19% patients had recurrent VTE. For each increase in CLT of 10 minutes, the crude relative risk (RR of recurrence was 1.13 (95% CI 1.02-1.25; p = 0.02 and was 1.08 (95% CI 0.98-1.20; p = 0.13 after adjustment for age and sex. For women only, the adjusted RR was 1.14 (95% CI, 0.91-1.42, p = 0.22 for each increase in CLT of 10 minutes. CLT values in the 4(th quartile of the female patient population, as compared to values in the 1(st quartile, conferred a risk of recurrence of 3.28 (95% CI, 1.07-10.05; p = 0.04. No association between CLT and recurrence risk was found in men. Hypofibrinolysis as assessed by CLT confers a moderate increase in the risk of recurrent VTE. A weak association between CLT and risk of recurrence was found in women only.

  10. Clotting of mammalian fibrinogens by papain: a re-examination.

    Science.gov (United States)

    Doolittle, Russell F

    2014-10-28

    Papain has long been known to cause the gelation of mammalian fibrinogens. It has also been reported that papain-fibrin is insoluble in dispersing solvents like strong urea or sodium bromide solutions, similar to what is observed with thrombin-generated clots in the presence of factor XIIIa and calcium. In those old studies, both the gelation and subsequent clot stabilization were attributed to papain, although the possibility that the second step might be due to contaminating factor XIII in fibrinogen preparations was considered. I have revisited this problem in light of knowledge acquired over the past half-century about thiol proteases like papain, which mostly cleave peptide bonds, and transglutaminases like factor XIIIa that catalyze the formation of ε-lysyl-γ-glutamyl cross-links. Recombinant fibrinogen, inherently free of factor XIII and other plasma proteins, formed a stable gel when treated with papain alone. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis revealed that the intermolecular cross-linking in papain-fibrin leads to γ-chain dimers, trimers, and tetramers, just as is the case with thrombin-factor XIIIa-stabilized fibrin. Mass spectrometry of bands excised from gels showed that the cross-linked material is quite different from what occurs with factor XIIIa, however. With papain, the cross-linking occurs between γ chains in neighboring protofibrils becoming covalently linked in a "head-to-tail" fashion by a transpeptidation reaction involving the α-amino group of γ-Tyr1 and a papain cleavage site at γ-Gly403 near the carboxy terminus, rather than by the (reciprocal) "tail-to-tail" manner that occurs with factor XIIIa and that depends on cross-links between γ-Lys406 and γ-Gln398.

  11. Phase transitions during compression and decompression of clots from platelet-poor plasma, platelet-rich plasma and whole blood.

    Science.gov (United States)

    Liang, Xiaojun; Chernysh, Irina; Purohit, Prashant K; Weisel, John W

    2017-09-15

    Blood clots are required to stem bleeding and are subject to a variety of stresses, but they can also block blood vessels and cause heart attacks and ischemic strokes. We measured the compressive response of human platelet-poor plasma (PPP) clots, platelet-rich plasma (PRP) clots and whole blood clots and correlated these measurements with confocal and scanning electron microscopy to track changes in clot structure. Stress-strain curves revealed four characteristic regions, for compression-decompression: (1) linear elastic region; (2) upper plateau or softening region; (3) non-linear elastic region or re-stretching of the network; (4) lower plateau in which dissociation of some newly made connections occurs. Our experiments revealed that compression proceeds by the passage of a phase boundary through the clot separating rarefied and densified phases. This observation motivates a model of fibrin mechanics based on the continuum theory of phase transitions, which accounts for the pre-stress caused by platelets, the adhesion of fibrin fibers in the densified phase, the compression of red blood cells (RBCs), and the pumping of liquids through the clot during compression/decompression. Our experiments and theory provide insights into the mechanical behavior of blood clots that could have implications clinically and in the design of fibrin-based biomaterials. The objective of this paper is to measure and mathematically model the compression behavior of various human blood clots. We show by a combination of confocal and scanning electron microscopy that compression proceeds by the passage of a front through the sample that separates a densified region of the clot from a rarefied region, and that the compression/decompression response is reversible with hysteresis. These observations form the basis of a model for the compression response of clots based on the continuum theory of phase transitions. Our studies may reveal how clot rheology under large compression in vivo due

  12. 7 CFR 58.436 - Rennet, pepsin, other milk clotting enzymes and flavor enzymes.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Rennet, pepsin, other milk clotting enzymes and flavor enzymes. 58.436 Section 58.436 Agriculture Regulations of the Department of Agriculture (Continued... clotting enzymes and flavor enzymes. Enzyme preparations used in the manufacture of cheese shall be safe...

  13. Fibronectin alters the rate of formation and structure of the fibrin matrix.

    Science.gov (United States)

    Ramanathan, Anand; Karuri, Nancy

    2014-01-10

    Plasma fibronectin is a vital component of the fibrin clot; however its role on clot structure is not clearly understood. The goal of this study was to examine the influence of fibronectin on the kinetics of formation, structural characteristics and composition of reconstituted fibrin clots or fibrin matrices. Fibrin matrices were formed by adding thrombin to 1, 2 or 4 mg/ml fibrinogen supplemented with 0-0.4 mg/ml fibronectin. The rate of fibrin matrix formation was then monitored by measuring light absorbance properties at different time points. Confocal microscopy of fluorescein conjugated fibrinogen was used to visualize the structural characteristics of fibrin matrices. The amount of fibronectin in fibrin matrices was determined through electrophoresis and immunoblotting of solubilized matrices. Fibronectin concentration positively correlated with the initial rate of fibrin matrix formation and with steady state light absorbance values of fibrin matrices. An increase in fibronectin concentration resulted in thinner and denser fibers in the fibrin matrices. Electrophoresis and immunoblotting showed that fibronectin was covalently and non-covalently bound to fibrin matrices and in the form of high molecular weight multimers. The formation of fibronectin multimers was attributed to cross-linking of fibronectin by trace amounts Factor XIIIa. These findings are novel because they link results from light absorbance studies to microcopy analyses and demonstrate an influence of fibronectin on fibrin matrix structural characteristics. This data is important in developing therapies that destabilize fibrin clots. Copyright © 2014. Published by Elsevier Inc.

  14. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    International Nuclear Information System (INIS)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip

    2008-01-01

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE

  15. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    Science.gov (United States)

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  16. Effect of low frequency ultrasound on combined rt-PA and eptifibatide thrombolysis in human clots.

    Science.gov (United States)

    Meunier, Jason M; Holland, Christy K; Pancioli, Arthur M; Lindsell, Christopher J; Shaw, George J

    2009-01-01

    Fibrinolytics such as recombinant tissue plasminogen activator (rt-PA) are used to treat thrombotic disease such as acute myocardial infarction (AMI) and ischemic stroke. Interest in increasing efficacy and reducing side effects has led to the study of adjuncts such as GP IIb-IIIa inhibitors and ultrasound (US) enhanced thrombolysis. Currently, GP IIb-IIIa inhibitor and fibrinolytic treatment are often used in AMI, and are under investigation for stroke treatment. However, little is known of the efficacy of combined GP IIb-IIIa inhibitor, fibrinolytic and ultrasound treatment. We measure the lytic efficacy of rt-PA, eptifibatide (Epf) and 120 kHz ultrasound treatment in an in-vitro human clot model. Blood was drawn from 15 subjects after IRB approval. Clots were made in 20 microL pipettes, and placed in a water tank for microscopic visualization during lytic treatment. Clots were exposed to control, rt-PA (rt-PA), eptifibatide (Epf), or rt-PA+eptifibatide (rt-PA + Epf), with (+US) or without (-US) ultrasound for 30 minutes at 37 degrees C in human plasma. Clot lysis was measured over time, using a microscopic imaging technique. The fractional clot loss (FCL) and initial lytic rate (LR) were used to quantify lytic efficacy. LR values for (- US) treated clots were 0.8+/-0.1(control), 1.8+/-0.3 (Epf), 1.5+/-0.2 (rt-PA), and 1.3+/-0.4 (rt-PA + Epf) (% clot width/minute) respectively. In comparison, the (+ US) group exhibited LR values of 1.6+/-0.2 (control), 4.3+/-0.4 (Epf), 6.3+/-0.4 (rt-PA), and 4.6+/-0.6 (rt-PA + Epf). For (- US) treated clots, FCL was 6.0+/-0.8 (control), 9.2+/-2.5 (Epf), 15.6+/-1.7 (rt-PA), and 28.0+/-2.2% (rt-PA + Epf) respectively. FCL for (+ US) clots was 13.5+/-2.4 (control), 20.7+/-6.4 (Epf), 44.4+/-3.6 (rt-PA) and 30.3+/-3.6% (rt-PA + Epf) respectively. Although the addition of eptifibatide enhances the in-vitro lytic efficacy of rt-PA in the absence of ultrasound, the efficacy of ultrasound and rt-PA is greater than that of combined

  17. Automated analysis for early signs of cerebral infarctions on brain X-ray CT images

    International Nuclear Information System (INIS)

    Oshima, Kazuki; Hara, Takeshi; Zhou, X.; Muramatsu, Chisako; Fujita, Hiroshi; Sakashita, Keiji

    2010-01-01

    t-PA (tissue plasminogen activator) thrombolysis is an effective clinical treatment for the acute cerebral infarction by breakdown to blood clots. However there is a risk of hemorrhage with its use. The guideline of the treatment is denying cerebral hemorrhage and widespread Early CT sign (ECS) on CT images. In this study, we analyzed the CT value of normal brain and ECS with normal brain model by comparing patient brain CT scan with a statistical normal model. Our method has constructed normal brain models consisted of 60 normal brain X-ray CT images. We calculated Z-score based on statistical model for 16 cases of cerebral infarction with ECS, 3 cases of cerebral infarction without ECS, and 25 cases of normal brain. The results of statistical analysis showed that there was a statistically significant difference between control and abnormal groups. This result implied that the automated detection scheme for ECS by using Z-score would be a possible application for brain computer-aided diagnosis (CAD). (author)

  18. The application of large amplitude oscillatory stress in a study of fully formed fibrin clots

    Science.gov (United States)

    Lamer, T. F.; Thomas, B. R.; Curtis, D. J.; Badiei, N.; Williams, P. R.; Hawkins, K.

    2017-12-01

    The suitability of controlled stress large amplitude oscillatory shear (LAOStress) for the characterisation of the nonlinear viscoelastic properties of fully formed fibrin clots is investigated. Capturing the rich nonlinear viscoelastic behaviour of the fibrin network is important for understanding the structural behaviour of clots formed in blood vessels which are exposed to a wide range of shear stresses. We report, for the first time, that artefacts due to ringing exist in both the sample stress and strain waveforms of a LAOStress measurement which will lead to errors in the calculation of nonlinear viscoelastic properties. The process of smoothing the waveforms eliminates these artefacts whilst retaining essential rheological information. Furthermore, we demonstrate the potential of LAOStress for characterising the nonlinear viscoelastic properties of fibrin clots in response to incremental increases of applied stress up to the point of fracture. Alternating LAOStress and small amplitude oscillatory shear measurements provide detailed information of reversible and irreversible structural changes of the fibrin clot as a consequence of elevated levels of stress. We relate these findings to previous studies involving large scale deformations of fibrin clots. The LAOStress technique may provide useful information to help understand why some blood clots formed in vessels are stable (such as in deep vein thrombosis) and others break off (leading to a life threatening pulmonary embolism).

  19. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination

    Directory of Open Access Journals (Sweden)

    Yutaka Kitamura

    2018-02-01

    Full Text Available Platelet-rich fibrin (PRF clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.

  20. Pre-analytical variation in glucose concentration due to atmospheric temperature and clot in blood specimens

    International Nuclear Information System (INIS)

    Butt, T.; Masud, K.; Khan, J.A.; Bhatti, M.S.

    2016-01-01

    Objective: To determine the effect of temperature and contact of clot with serum on laboratory results of glucose concentration in blood. Study Design: Quasi-experimental study. Place and Duration of Study: December 2014 to August 2015 at the laboratory of Shoaib Hospital, Fateh Jang, Attock Pakistan. Material and Methods: Samples were collected for estimation of blood glucose (Random) concentration from patients reporting to the hospital. Blood specimens (n=94) of such volunteers were analyzed for glucose level. Each sample was put up in five tubes. When the blood clotted the serum from tube-1 was analyzed for glucose level within 30 minutes. In tube-2 and tube-3 serum was kept for 24 hours at room temperature and refrigerator temperature respectively before glucose estimation. In tube-4 and tube-5 serum was not separated from clot and kept at room temperature and refrigerator temperature respectively before glucose estimation. The value of tube 1 was taken as reference value for comparison with other parts of the specimen. The equipment used for blood glucose level estimation was semi auto chemistry analyzer (Rayto, China). The kit used for analysis was Glucose - Liquizyme (Germany). Results: The difference between the mean reference value (tube-1) and refrigerated serum without clot (tube-3) was 4.63 mg/100 ml while that of unrefrigerated portion (tube-2) had a difference of 10.68 mg/100 ml. The mean of unrefrigerated (tube-4) and refrigerated (tube-5) portions of serum kept with the clot had difference of 42.05 mg/100 ml and 25.84 mg/100 ml respectively. The fall in the blood glucose level in all (n=94) the samples in the tube number 3 (serum separated and kept at refrigerated temperature) was 4.63 mg/100 ml +- 3.68 (Mean +- SD) and it ranged from 0 to 20 mg/100 ml whereas fall was maximum in the tube number 4 (serum with clotted blood and kept at room temperature) was 42.04 mg/100 ml +- 10.61 (Mean +- SD) and it ranged from 13 to 82 mg/100 ml. The sample in

  1. Fibrin Clots Are Equilibrium Polymers That Can Be Remodeled Without Proteolytic Digestion

    OpenAIRE

    Chernysh, Irina N.; Nagaswami, Chandrasekaran; Purohit, Prashant K.; Weisel, John W.

    2012-01-01

    Fibrin polymerization is a necessary part of hemostasis but clots can obstruct blood vessels and cause heart attacks and strokes. The polymerization reactions are specific and controlled, involving strong knob-into-hole interactions to convert soluble fibrinogen into insoluble fibrin. It has long been assumed that clots and thrombi are stable structures until proteolytic digestion. On the contrary, using the technique of fluorescence recovery after photobleaching, we demonstrate here that the...

  2. Identification and characterization of milk-clotting proteases ...

    African Journals Online (AJOL)

    SAM

    2014-03-12

    Mar 12, 2014 ... Biochem. Soc. Trans. 10:285. Hashem AM (2000). Purification and properities of a milk-clotting enzyme produced by Penicillium oxalicum. J. Bioresour. Technol. 75:219-222. Laemmli UK (1970). Cleavage of structural proteins during the assembly of the head of bacteriophage T4. Nature. 227: 680-685.

  3. Plasma fibrin clot properties in the G20210A prothrombin mutation carriers following venous thromboembolism: the effect of rivaroxaban.

    Science.gov (United States)

    Janion-Sadowska, Agnieszka; Natorska, Joanna; Siudut, Jakub; Ząbczyk, Michal; Stanisz, Andrzej; Undas, Anetta

    2017-08-30

    We sought to investigate whether the G20210A prothrombin mutation modifies plasma fibrin clot properties in patients after venous thromboembolism (VTE) and how rivaroxaban treatment affects these alterations. We studied 34 prothrombin mutation heterozygous carriers and sex- and age-matched 34 non-carriers, all at least three months since the first VTE episode, before and during treatment with rivaroxaban. Clot permeability (K s ) and clot lysis time (CLT) with or without elimination of thrombin activatable fibrinolysis inhibitor (TAFI) were assessed at baseline, 2-6 hours (h) after and 20-25 h after intake of rivaroxaban (20 mg/day). At baseline, the prothrombin mutation group formed denser clots (K s -12 %, p=0.0006) and had impaired fibrinolysis (CLT +14 %, p=0.004, and CLT-TAFI +13 %, p=0.03) compared with the no mutation group and were similar to those observed in 15 healthy unrelated prothrombin mutation carriers. The G20210A prothrombin mutation was the independent predictor for K s and CLT before rivaroxaban intake. At 2-6 h after rivaroxaban intake, clot properties improved in both G20210A carriers and non-carriers (K s +38 %, and +37 %, CLT -25 % and -25 %, CLT-TAFI -20 % and -24 %, respectively, all pCLT +17 %, CLT-TAFI +13 %, all p<0.001). Rivaroxaban concentration correlated with fibrin clot properties. After 20-25 h since rivaroxaban intake most clot properties returned to baseline. Rivaroxaban-related differences in clot structure were confirmed by scanning electron microscopy images. In conclusion, rivaroxaban treatment, though improves fibrin clot properties, cannot abolish more prothrombotic fibrin clot phenotype observed in prothrombin mutation carriers following VTE.

  4. Identification and characterization of milk-clotting proteases ...

    African Journals Online (AJOL)

    Two strains of fungi were isolated and identified as Aspergillus tamarii and Penicillium pinophilum which showed good enzymatic activity on casein, 1933.33U and 1822, 21U, respectively. The search for milk clotting enzymes by fermentation at acid pH on culture medium containing whey and, after purification by molecular ...

  5. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using 18F FDG PET/CT and 99mTc HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    International Nuclear Information System (INIS)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun

    2011-01-01

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent 99mT c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  6. CT perfusion mapping of hemodynamic disturbances associated to acute spontaneous intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Fainardi, Enrico; Borrelli, Massimo; Saletti, Andrea; Ceruti, Stefano; Tamarozzi, Riccardo; Schivalocchi, Roberta; Cavallo, Michele; Azzini, Cristiano; Chieregato, Arturo

    2008-01-01

    We sought to quantify perfusion changes associated to acute spontaneous intracerebral hemorrhage (SICH) by means of computed tomography perfusion (CTP) imaging. We studied 89 patients with supratentorial SICH at admission CT by using CTP scanning obtained within 24 h after symptom onset. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV) and mean transit time (rMTT) levels were measured in four different regions of interest manually outlined on CT scan: (1) hemorrhagic core; (2) perihematomal low-density area; (3) 1 cm rim of normal-appearing brain tissue surrounding the perilesional area; and (4) a mirrored area, including the clot and the perihematomal region, located in the non-lesioned contralateral hemisphere. rCBF, rCBV, and rMTT mean levels showed a centrifugal distribution with a gradual increase from the core to the periphery (p 20 ml) hematomas (p<0.01 and p <0.02, respectively). Multi-parametric CTP mapping of acute SICH indicates that perfusion values show a progressive improvement from the core to the periphery. In the first 24 h, perihemorrhagic region was hypoperfused with CTP values which were not suggestive of ischemic penumbra destined to survive but more likely indicative of edema formation. These findings also argue for a potential influence of early amounts of bleeding on perihematomal hemodynamic abnormalities. (orig.)

  7. Effects of botropase on clotting factors in healthy human volunteers

    Directory of Open Access Journals (Sweden)

    Ashok K Shenoy

    2014-01-01

    Full Text Available Objective: To evaluate the effects of botropase on various clotting factors in human volunteers. Materials and Methods: It was a prospective open label study conducted on human healthy volunteers. After the baseline screening, subjects fulfilling inclusion criteria were enrolled. On the study day, 1 ml of botropase was administered intravenously and after an hour same dose of botropase (1 ml was given by intramuscular (IM route. The efficacy and safety parameters were monitored up to 72 h from the time of intravenous (IV administration. Results: A total of 15 volunteers, belonging to 24-35 years of age were included in the study. Botropase significantly reduced the plasma level of fibrinogen and fibrin degradation products after 5 min of IV administration (P < 0.05. In addition, factor X was observed to reduce constantly by botropase administration suggesting enhanced turnover between 5 and 20 min of IV administration. Although botropase reduced clotting and bleeding time in all the volunteers, the data remains to be statistically insignificant. Conclusion: Present study demonstrated the safety and efficacy of botropase in human healthy volunteers. The study has shown that it is a factor X activator and reduces effectively clotting and bleeding time.

  8. Clinical aspects and prognosis of intraventricular hemorrhage with cerebrovascular disease. CT findings and etiological analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Yukio; Nakazawa, Shozo; Higuchi, Hiroshi; Ueda, Kenji; Kouzo, [Nippon Medical School, Tokyo

    1982-10-01

    Intraventricular hemorrhage with cerebrovascular disease was identified in 81 cases and death occurred within seven days in 34 cases. Hypertension was the most common etiological factor, accounting for 40 of the 81 cases. Cerebral aneurysm was the second most common cause accounting for 27 cases, arteriovenous malformation accounted for 9 of the cases, and 5 were of other causes. Signs of primary or secondary brain stem dysfunction were mainly seen in cases with hypertension and aneurysm, while cases with arteriovenous malformation had benign courses. The mortality depended on the severity of intraventricular hemorrhage; i.e., the distribution, site, and the number of cast formation. The presence of intraventricular clot in the third and/or fourth ventricles was correlated with a high mortality rate, especially in cases accompanied by cast formation and third and fourth ventricular dilatation, which affects hypothalamus and brain stem function. Analysis of CT findings for the mechanism of intraventricular hemorrhage revealed three types: extension type, in which massive intracerebral hematomas extended and ruptured into ventricles; the direct type, which bled directly into ventricles without forming definite intracerebral hematomas; and the reflux type, which was characterized by reflux of the subarachnoid blood.

  9. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time.

    Science.gov (United States)

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-12-01

    Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro.

  10. Honey Bee Venom (Apis mellifera Contains Anticoagulation Factors and Increases the Blood-clotting Time

    Directory of Open Access Journals (Sweden)

    Hossein Zolfagharian

    2015-12-01

    Full Text Available Objectives: Bee venom (BV is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Methods: Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50, and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE. Blood samples were obtained from 10 rabbits, and the prothrombin time (PT and the partial thromboplastin time (PTT tests were conducted. The approximate lethal dose (LD values of BV were determined. Results: Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa, respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. Conclusion: BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2 and melittin, and that can increase the blood clotting times in vitro.

  11. High-Quality and -Quantity DNA Extraction from Frozen Archival Blood Clots for Genotyping of Single-Nucleotide Polymorphisms

    DEFF Research Database (Denmark)

    Bank, Steffen; Nexø, Bjørn Andersen; Andersen, Vibeke

    2013-01-01

    the efficiency of commercial purification kits for extracting DNA from long-term frozen clotted blood. Methods: Serum tubes with clotted blood were stored at −20°C for 1 to 2.5 years before DNA extraction. DNA was extracted from 10 blood clot samples using PureGene (Qiagen) with and without glycogen, the QIAamp...... with a median of 0.65 μg (range 0.5–2.6 μg) pr 300 μL total blood. Conclusion: The yield obtained by the different commercial kits varied considerably. Our work demonstrates that high-quality and -quantity DNA can be extracted with the Maxwell 16 Blood purification kit (Promega) from cryopreserved blood clots...

  12. Makers of clotting medicine not entitled to liability shield.

    Science.gov (United States)

    1996-02-23

    The Indiana Court of Appeals, Second District, reversed a ruling that protected the manufacturer of a hemophilia blood clotting medicine from legal liability. A boy with hemophilia, known in court records as J.K.B. Jr., contracted HIV from the blood clotting medicine, Factor VIII. His parents sued four pharmaceutical companies, Armour Pharmaceutical Company, Cutter Laboratories, Baxter Healthcare Corporation, and Alpha Therapeutics Corporation, alleging that their products caused J.K.B. Jr.'s death. The companies convinced a Superior Court judge that they were protected under the Indiana Blood Shield Statute. The appeals court ruled that pharmaceutical companies are not included in the Blood Shield Statute. The statute was originally established to protect state-approved blood banks, hospitals, and blood storage facilities because they provide a vital public service.

  13. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  14. CT findings of fulminant subarachnoid hemorrhages

    International Nuclear Information System (INIS)

    Ikeda, Yukio; Isayama, Kazuo; Yajima, Kouzo; Nakazawa, Shozo; Yano, Masami; Otsuka, Toshibumi

    1985-01-01

    We studied the clinical features and CT findings of 20 cases with fulminant subarachonid hemorrhages in the acute stage. They were admitted to our hospital within 3 hours after the attack as DOA (dead on arrival) or near DOA. CT-visualized subarachnoid hemorrhages were located in the basal cisterns surrounding the brain stem in all cases. In 90 % of the cases, the subarachnoid hemorrhage formed a clot or a thick layer. Massive intracerebral hematomas were observed in 10 % of the cases. Acute intraventricular hemorrhages were seen in 80 % of the cases. The mechanism of intraventricular hemorrhage in 70 % of the cases was of the reflux type, which was characterized by a reflux of the severe subarachnoid hemorrhage in the basal cistern. Acute and diffuse brain swelling on CT scan was observed in several cases, which also showed initial increased intracranial pressures. The major mechanisms leading to acute death or a very severe state soon after subarachnoid hemorrhage might be caused by acute brain-stem failure due to severe subarachnoid hemorrhages in the basal cisterns surrounding the brain-stem and an acute increase in intracranial pressure by cerebral edema following subarachnoid hemorrhage and secondary cerebral ischemia due to cardiac and respiratory arrest. (author)

  15. Cloning and expression of clt genes encoding milk-clotting proteases from Myxococcus xanthus 422.

    Science.gov (United States)

    Poza, M; Prieto-Alcedo, M; Sieiro, C; Villa, T G

    2004-10-01

    The screening of a gene library of the milk-clotting strain Myxococcus xanthus 422 constructed in Escherichia coli allowed the description of eight positive clones containing 26 open reading frames. Only three of them (cltA, cltB, and cltC) encoded proteins that exhibited intracellular milk-clotting ability in E. coli, Saccharomyces cerevisiae, and Pichia pastoris expression systems.

  16. A constitutive model for developing blood clots with various compositions and their nonlinear viscoelastic behavior

    NARCIS (Netherlands)

    van Kempen, T. H. S.; Donders, W. P.; van de Vosse, F. N.; Peters, G. W. M.

    2016-01-01

    The mechanical properties determine to a large extent the functioning of a blood clot. These properties depend on the composition of the clot and have been related to many diseases. However, the various involved components and their complex interactions make it difficult at this stage to fully

  17. How to distinguish between bleeding and coagulated extradural hematomas on the plain CT scanning

    International Nuclear Information System (INIS)

    Petersen, O.F.; Espersen, J.O.

    1984-01-01

    Four types of extradural hematoma could be separated at examination of the plain CT scan in 54 extradural hematomas. Two major groups appear: the still bleeding hematoma showing either generally low attenuation values of ''holes'', and a coagulated homogenous type with generally high attenuation values. The attenuation values of the bleeding-liquid part of hematoma - were correlated to hemoglobin concentration in blood, to which clots were not related. Seven extradural hematomas grew and coagulated on repeated preoperative CT scans. In two cases intravenous contrast was given to the bleeding type of hematoma, and the contrast media appeared in ''holes'', but not in areas of high attenuation value. It is easy to distinguish between the different types of hematoma on the plain CT scan, and the separation by eye between the still bleeding and the coagulated extradural hematoma seems reliable. (orig.)

  18. Bone formation rather than inflammation reflects ankylosing spondylitis activity on PET-CT: a pilot study.

    Science.gov (United States)

    Bruijnen, Stefan T G; van der Weijden, Mignon A C; Klein, Joannes P; Hoekstra, Otto S; Boellaard, Ronald; van Denderen, J Christiaan; Dijkmans, Ben A C; Voskuyl, Alexandre E; van der Horst-Bruinsma, Irene E; van der Laken, Conny J

    2012-04-02

    Positron Emission Tomography - Computer Tomography (PET-CT) is an interesting imaging technique to visualize Ankylosing Spondylitis (AS) activity using specific PET tracers. Previous studies have shown that the PET tracers [18F]FDG and [11C](R)PK11195 can target inflammation (synovitis) in rheumatoid arthritis (RA) and may therefore be useful in AS. Another interesting tracer for AS is [18F]Fluoride, which targets bone formation. In a pilot setting, the potential of PET-CT in imaging AS activity was tested using different tracers, with Magnetic Resonance Imaging (MRI) and conventional radiographs as reference. In a stepwise approach different PET tracers were investigated. First, whole body [18F]FDG and [11C](R)PK11195 PET-CT scans were obtained of ten AS patients fulfilling the modified New York criteria. According to the BASDAI five of these patients had low and five had high disease activity. Secondly, an extra PET-CT scan using [18F]Fluoride was made of two additional AS patients with high disease activity. MRI scans of the total spine and sacroiliac joints were performed, and conventional radiographs of the total spine and sacroiliac joints were available for all patients. Scans and radiographs were visually scored by two observers blinded for clinical data. No increased [18F]FDG and [11C](R)PK11195 uptake was noticed on PET-CT scans of the first 10 patients. In contrast, MRI demonstrated a total of five bone edema lesions in three out of 10 patients. In the two additional AS patients scanned with [18F]Fluoride PET-CT, [18F]Fluoride depicted 17 regions with increased uptake in both vertebral column and sacroiliac joints. In contrast, [18F]FDG depicted only three lesions, with an uptake of five times lower compared to [18F]Fluoride, and again no [11C](R)PK11195 positive lesions were found. In these two patients, MRI detected nine lesions and six out of nine matched with the anatomical position of [18F]Fluoride uptake. Conventional radiographs showed structural

  19. CT findings of subdural hematomas: as a special references of atypical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Whi Yul; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Ki Whang; Park, Chang Yun [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1987-10-15

    Subdural hematomas (SDH) are relatively common and the typical CT findings according to the age of them are well established. The CT findings of 82 patients with SDHs were reviewed and compared with the operative findings. The results were as follow: 1. The most common cause of SDHs was the direct trauma which was noted in 60 cases (73.2%). 2. The atypical CT findings of the mixed density were seen in 19 cases (23.2%), including acute SDH 7 cases (20%), subacute SDH 5 cases (41.7%), and chronic SDH 7 cases (20%). 3. The possible causes of the mixed density in acute SDH were unclotted blood in early stage of hematoma development or serum extruded during the early phase of clot retraction. But the possibility of cerebrospinal fluid within subdural space due to an arachnoid tear could not be excluded. 4. The possible causes of the mixed density in subacute and chronic SDH were serum extruded during the hematoma resolution and rebleeding. 5. Wall enhancement of hematomas was noted in 3 cases (25%) of subacute SDHs and 15 cases (42.9%) of chronic SDHs. 6. Most of SDHs was crescentic in shape, but lenticular in 4 cases (4.9%). Midline shift and compression of ventricles were proportional to the maximum thickness of SDHs. There were seen ipsilateral dilatation of ventricles in 9 cases (11.0%) and brain edema in 11 cases (13.4%)

  20. Platelet factor XIII increases the fibrinolytic resistance of platelet-rich clots by accelerating the crosslinking of alpha 2-antiplasmin to fibrin

    Science.gov (United States)

    Reed, G. L.; Matsueda, G. R.; Haber, E.

    1992-01-01

    Platelet clots resist fibrinolysis by plasminogen activators. We hypothesized that platelet factor XIII may enhance the fibrinolytic resistance of platelet-rich clots by catalyzing the crosslinking of alpha 2-antiplasmin (alpha 2AP) to fibrin. Analysis of plasma clot structure by polyacrylamide gel electrophoresis and immunoblotting revealed accelerated alpha 2AP-fibrin crosslinking in platelet-rich compared with platelet-depleted plasma clots. A similar study of clots formed with purified fibrinogen (depleted of factor XIII activity), isolated platelets, and specific factor XIII inhibitors indicated that this accelerated crosslinking was due to the catalytic activity of platelet factor XIII. Moreover, when washed platelets were aggregated by thrombin, there was evidence of platelet factor XIII-mediated crosslinking between platelet alpha 2AP and platelet fibrin(ogen). Specific inhibition (by a monoclonal antibody) of the alpha 2AP associated with washed platelet aggregates accelerated the fibrinolysis of the platelet aggregate. Thus in platelet-rich plasma clots, and in thrombin-induced platelet aggregates, platelet factor XIII actively formed alpha 2AP-fibrin crosslinks, which appeared to enhance the resistance of platelet-rich clots to fibrinolysis.

  1. Methane hydrate distribution from prolonged and repeated formation in natural and compacted sand samples: X-ray CT observations

    Energy Technology Data Exchange (ETDEWEB)

    Rees, E.V.L.; Kneafsey, T.J.; Seol, Y.

    2010-07-01

    To study physical properties of methane gas hydrate-bearing sediments, it is necessary to synthesize laboratory samples due to the limited availability of cores from natural deposits. X-ray computed tomography (CT) and other observations have shown gas hydrate to occur in a number of morphologies over a variety of sediment types. To aid in understanding formation and growth patterns of hydrate in sediments, methane hydrate was repeatedly formed in laboratory-packed sand samples and in a natural sediment core from the Mount Elbert Stratigraphic Test Well. CT scanning was performed during hydrate formation and decomposition steps, and periodically while the hydrate samples remained under stable conditions for up to 60 days. The investigation revealed the impact of water saturation on location and morphology of hydrate in both laboratory and natural sediments during repeated hydrate formations. Significant redistribution of hydrate and water in the samples was observed over both the short and long term.

  2. Changes to the structure of blood clots formed in the presence of fine particulate matter

    International Nuclear Information System (INIS)

    Metassan, Sofian; Routledge, Michael N; Ariens, Robert A S; Scott, D Julian

    2009-01-01

    Both long-term and short-term exposure (one to two hours) to particulate matter are associated with morbidity and mortality caused by cardiovascular diseases. The underlying mechanisms leading to cardiovascular events are unclear, however, changes to blood coagulability upon exposure to ultrafine particulate matter (UFPM, the smallest of which can enter the circulation) is a plausible mechanism. Objectives: This study aims to investigate the direct effects of particulate matter on fibrin polymerization, lateral aggregation and the formation of fibrin network structure. Methods: Standard Urban Particulate Matter (PM) was suspended in Tris buffer centrifuged and filtered with <200nm filter to obtain ultrafine PM or their water-soluble components. Purified normal fibrinogen was made to clot by adding thrombin and calcium chloride in the presence of varying concentrations of PM. Permeation properties (Darcy constant [Ks]) and turbidity of clots were measured to investigate the effects on flow-rate, pore size, and fibrin polymerization. In addition, confocal microscopy was performed to study detailed clot structure. Results: Total PM increased the Ks of clots in a dose dependant manner (Ks = 4.4, 6.9 and 13.2 x 10-9 cm2 for 0, 50 and 100 |ag/ml total PM concentrations, respectively). Filtered PM also produced a significant increase in Ks at PM concentration of 17 |ag/ml. Final turbidity measurements at 20min were obtained for varying concentrations of PM. Maximum optical density (OD) for 1 mg/ml fibrinogen at 0, 50, 100 and 200 |ag/ml total PM concentrations were 0.39, 0.42, 0.45 and 0.46, respectively. The maximum OD for 0, 17, 34 and 68 |ag/ml filtered PM concentrations were 0.39, 0.42 0.47 and 0.51, respectively, suggesting an increase in fibre diameter with increasing particulate concentration. The lag phase was significantly shorter and the rate of polymerisation was significantly faster in the presence of 68 |ag/ml filtered PM. Confocal microscopy results showed

  3. CT and MRI diagnosis of tubo-ovarian masses

    International Nuclear Information System (INIS)

    Xiong Minghui; Zhang Wanshi; Wang Dong

    2000-01-01

    Objective: To evaluate the diagnostic value of CT and MRI in tubo-ovarian masses. Methods: CT scan was performed in 67 patients with tubo-ovarian masses confirmed by pathology. 19 of them underwent MRI. Results: (1) 20 primary malignant ovarian tumors showed cystic,solid or cystic-solid masses; papillary projections on cystic wall; pelvic organs and pelvic wall invasion. Chocolate cysts with malignant degeneration exhibited small nodules on thickened cystic wall on CT and MRI. T 1 WI was better for revealing the lesions. (2) Of 11 cases of metastasis to tubo-ovary, 4 showed peritoneal linear enhancement. (3) There were 9 cystadenomas and 2 adenofibromas, one of the cystadenomas contained fat, two adenofibromas were similar to uterus in density on CT while showing lower signal intensity on MRI (both T 1 WI and T 2 WI). (4) Three cases of thecoma exhibited cystic or solid masses, solid thecomas revealed granular enhancement. (5) Teratomas were most specific, one of them was associated with thecoma. (6) Tubo-ovarian abscesses and tuberculosis depicted cystic or cystic-solid masses. (7) Two cases of tubal pregnancy showed inhomogeneous soft tissue masses, the lower density areas in the centers were clot and organized tissues confirmed by pathology. Conclusion: (1) CT and MRI had higher sensitivity but lower specificity for tubo-ovarian masses, the diagnosis should be combined with clinical history and patients' age. (2) Tumors of two different types may coexist and sometimes fat may be present in tumors other than teratoma

  4. Fiber-based optic sensor for detecting human blood clot: present and future revival

    Science.gov (United States)

    Elshikeri, Nada; Bakhtiar, Hazri

    2018-05-01

    Sustaining human’s life-frame away from being impeded by the clot - ghost term, we attempt to approach a mobile fiber-based optical sensor (f-s) for detecting blood clot in a blood vessel (intra-arteries/veins). Blood vessels are the part of the circulatory system that transport blood throughout the human body, thus their significance of being protected arise to the monograph focus. MRI (magnetic resonance imaging), X-rays and other medical instruments are diagnostic immobility techniques with a slackest interval. The corer causation of fiber-based optical sensor is to detect a clump of blood in the bloodstream by providing a prompt mobile diagnostic intervals preserving last-minutes-breath of human’s life. The detector (f-s) has been etched by diluting sulphuric acid ~10% at certain zone to sensate its function. The in-vitro monograph peaks its maximal monitoring when the sensor is attached to Raman Spectroscopy (RS) setup. RS quantifies the relative intensities of fibrinogen bond, which is the first type of blood coagulation elements of blood plasma. Blood coagulation parameters are the major concern of the monograph investigation, such as total haemoglobin (tHb), clotting reaction time (t), clot progression time (t2), maximum clot amplitude (ma) and mean refractive index (r). A blood sample will be drawn from the patient and after centrifugation to separate blood plasma from its constituents, then an immediate sloshing of blood plasma in the (f-s) packet which has its plug-in to RS. Estimating the quantitative analysis of blood sample concentration, RS will determine the presence of coagulation in terms of intensity and medical procedures will dominate the treatment process. Thus, the suggestive monograph provides a definite instrument for investigating blood coagulation intra-arteries/veins promptly.

  5. Thrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes

    Directory of Open Access Journals (Sweden)

    Wai-Yoong Ng

    2013-01-01

    Full Text Available Clot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the test performance of BD vacutainer rapid serum tubes (RSTs compared to current institutional issued BD vacutainer serum separator tubes (SSTs in its test result comparability, clotting time, and stability on serum storage. Data from the study population (n=160 of patients attending outpatient clinics and healthy subjects showed that results for renal, liver, lipids, cardiac, thyroid, and prostate biochemical markers were comparable between RSTs and SSTs. Clotting times of the RSTs were verified to be quick with a median time of 2.05 min. Analyte stability on serum storage at 4°C showed no statistically significant deterioration except for bicarbonate, electrolytes, and albumin over a period of 4 days. In conclusion, RSTs offered savings in the time required for the clotting process of serum specimens. This should translate to further trimming of the whole process from blood collection to result reporting without too much sacrifice on test accuracy and performance compared to the current widely used SSTs in most clinical laboratories.

  6. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using {sup 18F} FDG PET/CT and {sup 99mT}c HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent {sup 99mT}c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  7. The Evaluation of Hydroxyethyl Starch (6% HES 130/0.4 Solution’s Potential Preventive Effects on Coagulation Status in Women with Gynecologic Malignancies Using Rotation Thromboelastography

    Directory of Open Access Journals (Sweden)

    Meltem Olga Akay

    2014-09-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the effects of in vitro hemodilution with 6% hydroxyethyl starch (HES 130/0.4 solution on the coagulation status of women with gynecologic malignancies by using rotation thromboelastogram (ROTEM®. METHODS: Twenty-two patients with gynecological tumors scheduled for anesthesia were enrolled. Blood samples were diluted by 20% with 6% HES (130/0.4 solution. RESULTS: In the INTEM assay, clotting time (CT (p<0.01 and clot formation time (CFT (p<0.001 were significantly increased and maximum maximum clot formation (MCF (p< 0.001 was significantly decreased in HES hemodilution compared with the undiluted control samples. In the EXTEM assay, there was a similar significant increase in increase in CFT (p<0.01 and a decrease in maximum a decrease in MCF (p<0.01 in HES hemodilution when compared with control samples. CONCLUSION: HES 130/0.4 solution causes significant hypocoagulable changes in the thromboelastographic profile of gynecologic cancer patients in vitro.

  8. Viscoelasticity as a measurement of clot structure in poorly controlled type 2 diabetes patients: towards a precision and personalized medicine approach.

    Science.gov (United States)

    Pretorius, Etheresia; Bester, Janette

    2016-08-09

    Type 2 diabetes patients (T2D) have a considerably higher cardiovascular risk, which is closely associated with systemic inflammation, and an accompanying pathologic coagulation system. Due to the complexity of the diabetic profile, we suggest that we need to look at each patient individually and particularly at his or her clotting profile; as the healthiness of the coagulation system gives us an indication of the success of clinical intervention. T2D coagulability varied markedly, although there were no clear difference in medication use and the standards of HbA1c levels. Our sample consisted of 90 poorly controlled T2D and 71 healthy individuals. We investigated the medication use and standards of HbA1c levels of T2D and we used thromboelastography (TEG) and scanning electron microscopy (SEM) to study their clot formation. The latest NIH guidelines suggest that clinical medicine should focus on precision medicine, and the current broad understanding is that precision medicine may in future, provide personalized targets for preventative and therapeutic interventions. Here we suggest a practical example where TEG can be used as an easily accessible point-of-care tool to establish a comprehensive clotting profile analysis for T2D patients; and additionally may provide valuable information that may be used in the envisaged precision medicine approach. Only by closely following each individual patient's progress and healthiness and thereby managing systemic inflammation, will we be able to reduce this pandemic.

  9. Quantifying the degradation of degradable implants and bone formation in the femoral condyle using micro-CT 3D reconstruction.

    Science.gov (United States)

    Xu, Yichi; Meng, Haoye; Yin, Heyong; Sun, Zhen; Peng, Jiang; Xu, Xiaolong; Guo, Quanyi; Xu, Wenjing; Yu, Xiaoming; Yuan, Zhiguo; Xiao, Bo; Wang, Cheng; Wang, Yu; Liu, Shuyun; Lu, Shibi; Wang, Zhaoxu; Wang, Aiyuan

    2018-01-01

    Degradation limits the application of magnesium alloys, and evaluation methods for non-traumatic in vivo quantification of implant degradation and bone formation are imperfect. In the present study, a micro-arc-oxidized AZ31 magnesium alloy was used to evaluate the degradation of implants and new bone formation in 60 male New Zealand white rabbits. Degradation was monitored by weighing the implants prior to and following implantation, and by performing micro-computed tomography (CT) scans and histological analysis after 1, 4, 12, 24, 36, and 48 weeks of implantation. The results indicated that the implants underwent slow degradation in the first 4 weeks, with negligible degradation in the first week, followed by significantly increased degradation during weeks 12-24 (Pformation increased as the implant degraded. The findings concluded that micro-CT, which is useful for providing non-traumatic, in vivo , quantitative and precise data, has great value for exploring the degradation of implants and novel bone formation.

  10. Changes in clot lysis levels of reteplase and streptokinase following continuous wave ultrasound exposure, at ultrasound intensities following attenuation from the skull bone

    Directory of Open Access Journals (Sweden)

    Roijer Anders

    2008-08-01

    Full Text Available Abstract Background Ultrasound (US has been used to enhance thrombolytic therapy in the treatment of stroke. Considerable attenuation of US intensity is however noted if US is applied over the temporal bone. The aim of this study was therefore to explore possible changes in the effect of thrombolytic drugs during low-intensity, high-frequency continuous-wave ultrasound (CW-US exposure. Methods Clots were made from fresh venous blood drawn from healthy volunteers. Each clot was made from 1.4 ml blood and left to coagulate for 1 hour in a plastic test-tube. The thrombolytic drugs used were, 3600 IU streptokinase (SK or 0.25 U reteplase (r-PA, which were mixed in 160 ml 0.9% NaCl solution. Continuous-wave US exposure was applied at a frequency of 1 MHz and intensities ranging from 0.0125 to 1.2 W/cm2. For each thrombolytic drug (n = 2, SK and r-PA and each intensity (n = 9 interventional clots (US-exposed, n = 6 were submerged in thrombolytic solution and exposed to CW-US while control clots (also submerged in thrombolytic solution, n = 6 were left unexposed to US. To evaluate the effect on clot lysis, the haemoglobin (Hb released from each clot was measured every 20 min for 1 hour (20, 40 and 60 min. The Hb content (mg released was estimated by spectrophotometry at 540 nm. The difference in effect on clot lysis was expressed as the difference in the amount of Hb released between pairs of US-exposed clots and control clots. Statistical analysis was performed using Wilcoxon's signed rank test. Results Continuous-wave ultrasound significantly decreased the effects of SK at intensities of 0.9 and 1.2 W/cm2 at all times (P 2 and at 1.2 W/cm2, following 40 min exposure at 0.3, 0.6, 0.9 and at 1.2 W/cm2, and following 60 min of exposure at 0.05 0.3, 0.6, 0.9 and at 1.2 W/cm2 (all P Conclusion Increasing intensities of CW-US exposure resulted in increased clot lysis of r-PA-treated blood clots, but decreased clot lysis of SK-treated clots.

  11. Diagnosis of hemoparasitosis trough the spread-smear technique using a drop of blood clot

    OpenAIRE

    Neusa Saltiél Stobbe; Eunice Leonora Chaplin; Maria das Graças de Souza Paiva; Nilton Rogério Santos Silva; Flávio A. Pacheco Araújo; Elinor Fortes

    1992-01-01

    The spread-smear technique using a drop of blood clot and stained by diluted and undimitcd Giemsa stain was evaluated for the search of blood cell types and recognition of Babesia bovis, Babesia bigemina and Anaplasma marginale hemoparasites. The blood clot samples were taken from a 6 month-old calf experimentally inoculated with the blood from a Cattle Tick Fever carrier. The Technique was sumitable for the observation of different blood cells and for the recognition of the hemoparasites.

  12. Lung cancer mimicking lung abscess formation on CT images.

    Science.gov (United States)

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  13. Evaluation of the effects of levobupivacaine on clotting and fibrinolysis using thromboelastography.

    LENUS (Irish Health Repository)

    Leonard, S A

    2012-02-03

    Amide local anaesthetics inhibit platelet function. We hypothesized that residual anaesthetic in the epidural space could decrease efficacy of an epidural blood patch in preventing postdural puncture headache. Levobupivacaine has recently been approved for epidural anaesthesia. Its effects on coagulation have not previously been studied. The aim of this study was to determine the effects of levobupivacaine on clotting using thromboelastography. Ten ASA Class I volunteers were studied. Venous blood samples were analysed using a Haemoscope 2000D TEG analyser. Whole blood, a 50% saline control and two levobupivacaine solutions (2.5 mg mL(-1) and 2.5 microg mL(-1) in blood) were compared. The former reproduces that produced in the epidural space by blood (20 mL for an epidural blood patch) and levobupivacaine 0.5% (20 mL). The latter approximates plasma concentrations following epidural injection of levobupivacaine 0.5% (20 mL). P < 0.05 was considered significant. Maximum amplitude (MA), a measure of clot strength, is decreased by levobupivacaine 2.5 mg mL(-1). Levobupivacaine 2.5 mg mL(-1) decreases clot strength and may reduce efficacy of a prophylactic epidural blood patch.

  14. The use of alteplase for the resolution of an intravesical clot in a neonate receiving extracorporeal membrane oxygenation.

    Science.gov (United States)

    Olarte, J L; Glover, M L; Totapally, B R

    2001-01-01

    We present a case of the use of alteplase for the lysis of a large urinary bladder clot. A neonate presented with respiratory failure, secondary to a left diaphragmatic hernia necessitating the need for extracorporeal membrane oxygenation (ECMO) support. On day 3 of ECMO support, hematuria was noted, and a subsequent urinary bladder ultrasound revealed a significant urinary bladder clot. Alteplase (0.5-1 mg) was instilled into the urinary bladder via a 10 French Foley catheter (Sherwood Medical, St. Louis, MO). The catheter was clamped for 1 hour, followed by irrigation with normal saline. Multiple doses of alteplase were administered, resulting in complete resolution of the bladder clot. No adverse effects were attributed to the use of the intravesical alteplase. Alteplase seems to be safe and effective for the resolution of bladder clots, thereby potentially avoiding more invasive surgical procedures.

  15. The effect of sepsis and septic shock on the viscoelastic properties of clot quality and mass using rotational thromboelastometry: A prospective observational study.

    Science.gov (United States)

    Davies, Gareth R; Lawrence, Matthew; Pillai, Suresh; Mills, Gavin M; Aubrey, Robert; Thomas, Dafydd; Williams, Rhodri; Morris, Keith; Evans, Phillip Adrian

    2018-04-01

    The study purpose was to define changes in coagulation across the sepsis spectrum using rotational thromboelastometry (ROTEM). Sepsis patients were recruited on admission to the Emergency Department and Intensive Care Units of a large teaching hospital in Wales. ROTEM markers of clot development and fibrinolysis were determined, as well as standard coagulation markers. A healthy control group matched for age and gender was also recruited (n=44). 100 patients were recruited (50 sepsis, 20 severe sepsis and 30 septic shock). Maximum clot firmness was significantly higher in the sepsis (p<0.001) and severe sepsis (p=0.012) groups than the healthy control (71.6±4.5 and 70.4±4.1 vs 64.4 respectively). In septic shock there was prolonged clot development; however, maximum clot firmness remained normal. Fibrinolytic function was significantly impaired in septic shock, which was also significantly associated with 28-day mortality (p<0.001). ROTEM indicated significantly enhanced clot structural development in sepsis and severe sepsis, which could be indicative of a hypercoagulable phase. In septic shock, despite there being a prolongation of clotting pathways and impaired fibrinolysis, clot mass was comparably normal, suggestive of the development of a clot with healthy characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Diagnosis of hemoparasitosis trough the spread-smear technique using a drop of blood clot

    Directory of Open Access Journals (Sweden)

    Neusa Saltiél Stobbe

    1992-12-01

    Full Text Available The spread-smear technique using a drop of blood clot and stained by diluted and undimitcd Giemsa stain was evaluated for the search of blood cell types and recognition of Babesia bovis, Babesia bigemina and Anaplasma marginale hemoparasites. The blood clot samples were taken from a 6 month-old calf experimentally inoculated with the blood from a Cattle Tick Fever carrier. The Technique was sumitable for the observation of different blood cells and for the recognition of the hemoparasites.

  17. Clotting mechanism in beagles irradiated by 4.5 Gy γ-rays

    International Nuclear Information System (INIS)

    Zhao Zhenhu; Wang Ning; Li Ming; Xing Shuang; Huang Haixiao; Ou Hongling; Xiong Guolin; Zhao Yanfang; Xie Ling; Wang Jinxiang; Miao Jingcheng; Zhu Nankang; Zhang Xueguang; Luo Qingliang; Cong Yuwen

    2010-01-01

    Objective: To explore the clotting mechanism in beagles irradiated by 4.5 Gy γ-rays after treatment with supportive care, or supportive care and combined cytokines. Methods: Sixteen beagles were divided into irradiation control group, Supportive care group and combined cytokines treatment group. Platelet aggregation test, thrombelastography (TEG) and the time measurement were analyzed in vitro. Results: In irradiation group and supportive care group, the platelet aggregation rates in beagles were decreased markedly and the k value of TEG was increased 7 d post-irradiation, while those indexes in combined cytokines treatment group changed little. At 14 d post-irradiation, each parameter of TEG in irradiated group changed obviously. The values of r, k, r + k and M were elevated significantly, clotting time and the maximum coagulation time of thrombus delayed, the Ma value was decreased markedly, and the maximum elasticity amplitude of thrombus was diminished. All parameters in combined cytokines treatment group were better than those in supportive care group. The thrombin time was prolonged obviously in irradiated group 14 d post-irradiation, while the thrombin time was the longest at 2-3 weeks post irradiation in supportive care group and combined cytokines treatment group (P>0.05). Conclusions: Cytokines could improve the platelet aggregation and the blood clotting functions of beagles suffering from acute radiation sickness. (authors)

  18. What is this chocolate milk in my circuit? A cause of acute clotting of a continuous renal replacement circuit: Questions.

    Science.gov (United States)

    Kakajiwala, Aadil; Chiotos, Kathleen; Brothers, Julie; Lederman, April; Amaral, Sandra

    2016-12-01

    One of the greatest problems associated with continuous renal replacement therapy (CRRT) is the early clotting of filters. A literature search revealed three case reports of lipemic blood causing recurrent clotting and reduced CRRT circuit survival time in adult patients, but no reports of cases in children. A 23-month-old male infant with Martinez-Frias syndrome and multivisceral transplant was admitted to the hospital with severe sepsis and hemolytic anemia. He developed acute kidney injury, fluid overload and electrolyte imbalances requiring CRRT and was also administered total parenteral nutrition (TPN) and fat emulsion. The first circuit lasted 60 h before routine change was required. The second circuit showed acute clotting after only 18 h, and brownish-milky fluid was found in the circuit tubing layered between the clotted blood. The patient's serum triglyceride levels were elevated at 988 mg/dL. The lipid infusion was stopped and CRRT restarted. Serum triglyceride levels improved to 363 mg/dL. The new circuit lasted 63 h before routine change was required. Clotting of CRRT circuits due to elevated triglyceride levels is rare and has not been reported in the pediatric population. Physicians should be mindful of this risk in patients receiving TPN who have unexpected clotting of CRRT circuits.

  19. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  20. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  1. Iodinated Contrast Does Not Alter Clotting Dynamics in Acute Ischemic Stroke as Measured by Thromboelastography

    Science.gov (United States)

    McDonald, Mark M; Archeval-Lao, Joancy M; Cai, Chunyan; Peng, Hui; Sangha, Navdeep; Parker, Stephanie A; Wetzel, Jeremy; Riney, Stephen A; Cherches, Matt F; Guthrie, Greer J; Roper, Tiffany C; Kawano-Castillo, Jorge F; Pandurengan, Renga; Rahbar, Mohammad H; Grotta, James C

    2014-01-01

    Background and Purpose Iodinated contrast agents used for computed tomography angiography (CTA) may alter fibrin fiber characteristics and decrease fibrinolysis by tissue plasminogen activator (tPA). Thromboelastography (TEG™) measures the dynamics of coagulation and correlates with thrombolysis in acute ischemic stroke (AIS) patients. We hypothesized that receiving CTA prior to tPA will not impair thrombolysis as measured by TEG™. Methods AIS patients receiving 0.9 mg/kg tPA within 4.5 hours of symptom onset were prospectively enrolled. For CTA, 350 mg/dL of iohexol or 320 mg/dL of iodixanol at a dose of 2.2 ml/kg was administered. TEG™ was measured prior to tPA and 10-minutes after tPA bolus. CTA timing was left to the discretion of the treating physician. Results Of 136 AIS patients who received tPA, 47 had CTA prior to tPA bolus, and 42 had either CTA following tPA and post-tPA TEG™ draw or no CTA (non-contrast group). The median change in clot lysis (LY30) following tPA was 95.3% in the contrast group vs. 95.0% in the non-contrast group (p = 0.74). Thus, tPA-induced thrombolysis did not differ between contrast and non-contrast groups. Additionally, there was no effect of contrast on any pre-tPA TEG™ value. Conclusions Our data do not support an effect of iodinated contrast agents on clot formation or tPA activity. PMID:24370757

  2. Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment

    Science.gov (United States)

    Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro

    2016-01-01

    The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma. PMID:27009516

  3. Unfavorably Altered Fibrin Clot Properties in Patients with Eosinophilic Granulomatosis with Polyangiitis (Churg-Strauss Syndrome): Association with Thrombin Generation and Eosinophilia.

    Science.gov (United States)

    Mastalerz, Lucyna; Celińska-Lӧwenhoff, Magdalena; Krawiec, Piotr; Batko, Bogdan; Tłustochowicz, Witold; Undas, Anetta

    2015-01-01

    Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome), we investigated whether fibrin clot properties are unfavorably altered in EGPA. Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male), aged 48 (range, 21-80) years. The control group comprised 34 age- and sex- matched volunteers. Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2), faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s), thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07), higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L), and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min); all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%. This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.

  4. Unfavorably Altered Fibrin Clot Properties in Patients with Eosinophilic Granulomatosis with Polyangiitis (Churg-Strauss Syndrome: Association with Thrombin Generation and Eosinophilia.

    Directory of Open Access Journals (Sweden)

    Lucyna Mastalerz

    Full Text Available Given reports on the increased prevalence of thromboembolic incidents in patients with eosinophilic granulomatosis with polyangiitis (EGPA; Churg-Strauss syndrome, we investigated whether fibrin clot properties are unfavorably altered in EGPA.Ex vivo plasma fibrin clot characteristics, including clot permeability, turbidimetry and efficiency of fibrinolysis using two assays, were investigated in 34 consecutive patients with remission in EGPA according to the Birmingham Vasculitis Activity Score version 3 (23 female, 11 male, aged 48 (range, 21-80 years. The control group comprised 34 age- and sex- matched volunteers.Compared with controls, patients with EGPA were characterized by denser fiber clots (estimated pore size, Ks, 7.30±0.93 vs 10.14±1.07 10-9 cm2, faster fibrin polymerization (lag phase in a turbidimetric curve, 41.8±3.6 vs 47.4±2.9 s, thicker fibrin fibers (maximum absorbance, ΔAbs, 0.87±0.09 vs 0.72±0.07, higher maximum levels of D-dimer released from clots (DDmax 4.10±0.46 vs 3.54±0.35 mg/L, and prolonged clot lysis time (t50%; 9.50±1.45 vs 7.56±0.87 min; all p<0.0001. Scanning electron microscopy images confirmed denser plasma fibrin networks composed of thinner fibers formed in EGPA. Antineutrophil cytoplasmic antibody status and C-reactive protein did not affect clot variables. Multivariate analysis adjusted for fibrinogen showed that Ks was predicted by eosinophil count, peak thrombin generation, factor VIII, and soluble CD40 ligand, whereas eosinophil count, peak thrombin generation and antiplasmin predicted t50%.This study is the first to show that EGPA is associated with prothrombotic plasma fibrin clot phenotype, which may contribute to thromboembolic manifestations reported in this disease.

  5. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Activated whole blood clotting time tests. 864.7140 Section 864.7140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864...

  6. Long-term cytokine and growth factor release from equine platelet-rich fibrin clots obtained with two different centrifugation protocols.

    Science.gov (United States)

    Jiménez-Aristizabal, Román F; López, Catalina; Álvarez, María E; Giraldo, Carlos; Prades, Marta; Carmona, Jorge U

    2017-09-01

    To compare the temporal release (over three weeks) of tumor necrosis factor alpha (TNF-α), interleukin 4 (IL-4), IL-1 receptor antagonist (IL-1ra), platelet-derived growth factor BB (PDGF-BB) and transforming growth factor beta-1 (TGF-β 1 ) from two platelet-rich fibrin (PRF) preparations from equine blood obtained at either 240g/8min or 416g/10min. Whole blood from 10 horses was used to obtain PRF clots by two different centrifugation protocols. After 1h of rest, PRF clots were deposited in wells with culture medium, which was changed at 6h, 24h and then every 48h to 21days. Cytokines and GFs were measured by ELISA at 1h (serum supernatants from PRF clots) and all time points of culture medium change. A negative control (plasma) and a positive control (blood lysate) were also included. There were no relevant differences between the two protocols for the temporal release of proteins. However, a significant (p=0.01) effect of time was noted. All cytokines were detected after 6h of PRF clot culture until day 21. GF were detected at 1h until day 21. The concentrations for these proteins diminished gradually over time. A highly significant (p=0.01) correlation was noticed between all the proteins evaluated. Leukocytes enmeshed in PRF clots were able to produce cytokines, TGF-β 1 and PDGF-BB. These findings demonstrate a paramount role of leukocytes in wound healing induced or modified by PRF clots in mammals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Purification and characterization of a milk-clotting protease from ...

    African Journals Online (AJOL)

    Crude enzymatic extract obtained from five fermentations (300 g of wheat bran) was characterized by a clotting activity of 0.34 ± 0.08 UP/ml with a strength ratio of 1/1: 200. The comparative study of the summaries from 2 purification protocols showed that it is possible to recover 6% of the initial proteins with a 44.54% activity ...

  8. Intravenous flat-detector CT angiography in acute ischemic stroke management

    Energy Technology Data Exchange (ETDEWEB)

    Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands); Obadia, Michael [Fondation Rothschild Hospital, Department of Neurology, Paris (France); Alamowitch, Sonia [APHP Hopital Tenon, Universite Paris VI, Department of Neurology, Paris (France)

    2012-04-15

    In the settings of stroke, a non-invasive high-resolution imaging modality to visualize the arterial intracranial circulation in the interventional lab is a helpful mean to plan the endovascular recanalization procedure. We report our initial experience with intravenously enhanced flat-detector CT (IV FDCT) technology in the detection of obstructed intracranial arteries. Fourteen consecutive patients elected for endovascular stroke therapy underwent IV FDCT. The scans were intravenously enhanced and acquired in accordance with the previously calculated bolus arrival time. Images were processed on a commercially available workstation for reconstructions and 3D manipulation. Occlusion level and clot length, the quality of collateral vessels, and the patency of anterior and posterior communicating arteries were assessed. IV FDCT was performed successfully in all the cases and allowed for clot location and length visualization, assessment of communicating arteries patency, and evaluation of vessel collateral grade. Information obtained from this technique was considered useful for patients treated by endovascular approach. Retrospective review of the images by two independent readers was considered accurate and reproducible. IV FDCT technology provided accurate delineation of obstructed vessel segments in acute ischemic stroke disease. It gave a significant help in the interventional strategy. This new technology available in the operating room might provide a valuable tool in emerging endovascular stroke therapy. (orig.)

  9. Intravenous flat-detector CT angiography in acute ischemic stroke management

    International Nuclear Information System (INIS)

    Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel; Babic, Drazenko; Obadia, Michael; Alamowitch, Sonia

    2012-01-01

    In the settings of stroke, a non-invasive high-resolution imaging modality to visualize the arterial intracranial circulation in the interventional lab is a helpful mean to plan the endovascular recanalization procedure. We report our initial experience with intravenously enhanced flat-detector CT (IV FDCT) technology in the detection of obstructed intracranial arteries. Fourteen consecutive patients elected for endovascular stroke therapy underwent IV FDCT. The scans were intravenously enhanced and acquired in accordance with the previously calculated bolus arrival time. Images were processed on a commercially available workstation for reconstructions and 3D manipulation. Occlusion level and clot length, the quality of collateral vessels, and the patency of anterior and posterior communicating arteries were assessed. IV FDCT was performed successfully in all the cases and allowed for clot location and length visualization, assessment of communicating arteries patency, and evaluation of vessel collateral grade. Information obtained from this technique was considered useful for patients treated by endovascular approach. Retrospective review of the images by two independent readers was considered accurate and reproducible. IV FDCT technology provided accurate delineation of obstructed vessel segments in acute ischemic stroke disease. It gave a significant help in the interventional strategy. This new technology available in the operating room might provide a valuable tool in emerging endovascular stroke therapy. (orig.)

  10. Effect of sugammadex on coagulation as detected by rotational thromboelastometry in morbidly obese patients.

    Science.gov (United States)

    Carron, Michele; Bertini, Diana; Prandini, Tancredi; Fanton, Francesca; Foletto, Mirto; Ori, Carlo; Perissinotto, Egle; Simioni, Paolo

    2018-02-01

    Sugammadex, which is used to reverse rocuronium-induced neuromuscular blockade, has a limited and transient effect on activated partial thromboplastin time and prothrombin time. However, no data are available on the effects of sugammadex on coagulation in morbidly obese patients, as assessed by rotational thromboelastometry (ROTEM®). Sixty patients received sugammadex 2 mg/kg or 4 mg/kg to reverse moderate or deep rocuronium-induced neuromuscular blockade (N.=30/group) at the end of surgery under desflurane anesthesia. Arterial blood samples were collected before and 3 min and 30 min after sugammadex administration for ROTEM® analysis, including measurements of clotting time (CT), clot formation time, α angle, and maximum clot firmness in INTEM, EXTEM, and FIBTEM assays. Major and minor bleeding events were also monitored during the postoperative period. Sugammadex 2 and 4 mg/kg has a limited and transient (sugammadex dose (500 mg) on the INTEM CT (P=0.002). A regression analysis showed a positive relationship between sugammadex dose and INTEM CT value at 3 min after administration (coefficient = 0.052 s; 95% CI: 0.005-0.098 s; P=0.03). No major or minor bleeding events were observed in either group during the postoperative period. Sugammadex produces a slight effect on coagulation in morbidly obese patients, without increasing the risk for postoperative bleeding.

  11. Ruptured corpus luteal cyst: Prediction of clinical outcomes with CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok; Moon, Min Hoan; Woo, Hyun Sik; Sung, Chang Kyu; Jeon, Hye Won; Lee, Taek Sang [SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    To evaluate the determinant pretreatment CT findings that can predict surgical intervention for patients suffering from corpus luteal cyst rupture with hemoperitoneum. From January 2009 to December 2014, a total of 106 female patients (mean age, 26.1 years; range, 17–44 years) who visited the emergency room of our institute for acute abdominal pain and were subsequently diagnosed with ruptured corpus luteal cyst with hemoperitoneum were included in the retrospective study. The analysis of CT findings included cyst size, cyst shape, sentinel clot sign, ring of fire sign, hemoperitoneum depth, active bleeding in portal phase and attenuation of hemoperitoneum. The comparison of CT findings between the surgery and conservative management groups was performed with the Mann-Whitney U test or chi-square test. Logistic regression analysis was used to determine significant CT findings in predicting surgical intervention for a ruptured cyst. Comparative analysis revealed that the presence of active bleeding and the hemoperitoneum depth were significantly different between the surgery and conservative management groups and were confirmed as significant CT findings for predicting surgery, with adjusted odds ratio (ORs) of 3.773 and 1.318, respectively (p < 0.01). On the receiver-operating characteristic curve analysis for hemoperitoneum depth, the optimal cut-off value was 5.8 cm with 73.7% sensitivity and 58.6% specificity (Az = 0.711, p = 0.004). In cases with a hemoperitoneum depth > 5.8 cm and concurrent active bleeding, the OR for surgery increased to 5.786. The presence of active bleeding and the hemoperitoneum depth on a pretreatment CT scan can be predictive warning signs of surgery for a patient with a ruptured corpus luteal cyst with hemoperitoneum.

  12. Three-dimensional architecture and cell composition of a Choukroun's platelet-rich fibrin clot and membrane.

    Science.gov (United States)

    Dohan Ehrenfest, David M; Del Corso, Marco; Diss, Antoine; Mouhyi, Jaafar; Charrier, Jean-Baptiste

    2010-04-01

    Platelet-rich fibrin (PRF; Choukroun's technique) is a second-generation platelet concentrate for surgical use. This easy protocol allows the production of leukocyte and platelet-rich fibrin clots and membranes starting from 10-ml blood samples. The purposes of this study were to determine the cell composition and three-dimensional organization of this autologous biomaterial and to evaluate the influence of different collection tubes (dry glass or glass-coated plastic tubes) and compression procedures (forcible or soft) on the final PRF-membrane architecture. After centrifugation, blood analyses were performed on the residual waste plasmatic layers after collecting PRF clots. The PRF clots and membranes were processed for examination by light microscopy and scanning electron microscopy. Approximately 97% of the platelets and >50% of the leukocytes were concentrated in the PRF clot and showed a specific three-dimensional distribution, depending on the centrifugation forces. Platelets and fibrin formed large clusters of coagulation in the first millimeters of the membrane beyond the red blood cell base. The fibrin network was very mature and dense. Moreover, there was no significant difference in the PRF architecture between groups using the different tested collection tubes and compression techniques, even if these two parameters could have influenced the growth factor content and biologic matrix properties. The PRF protocol concentrated most platelets and leukocytes from a blood harvest into a single autologous fibrin biomaterial. This protocol offers reproducible results as long as the main production principles are respected.

  13. Increased Oxidation as an Additional Mechanism Underlying Reduced Clot Permeability and Impaired Fibrinolysis in Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Anna Lados-Krupa

    2015-01-01

    Full Text Available Aims. We sought to investigate whether enhanced oxidation contributes to unfavorable fibrin clot properties in patients with diabetes. Methods. We assessed plasma fibrin clot permeation (Ks, a measure of the pore size in fibrin networks and clot lysis time induced by recombinant tissue plasminogen activator (CLT in 163 consecutive type 2 diabetic patients (92 men and 71 women aged 65 ± 8.8 years with a mean glycated hemoglobin (HbA1c of 6.8%. We also measured oxidative stress markers, including nitrotyrosine, the soluble form of receptor for advanced glycation end products (sRAGE, 8-iso-prostaglandin F2α (8-iso-PGF2α, oxidized low-density lipoprotein (oxLDL, and advanced glycation end products (AGE. Results. There were inverse correlations between Ks and nitrotyrosine, sRAGE, 8-iso-PGF2α, and oxLDL. CLT showed a positive correlation with oxLDL and nitrotyrosine but not with other oxidation markers. All these associations remained significant for Ks after adjustment for fibrinogen, disease duration, and HbA1c (all P<0.05, while oxLDL was the only independent predictor of CLT. Conclusions. Our study shows that enhanced oxidative stress adversely affects plasma fibrin clot properties in type 2 diabetic patients, regardless of disease duration and glycemia control.

  14. High-precision surface formation method and the 3-D shaded display of the brain obtained from CT images

    International Nuclear Information System (INIS)

    Niki, Noboru; Fukuda, Hiroshi

    1987-01-01

    Our aim is to display the precise 3-D appearance of the brain based on data provided by CT images. For this purpose, we have developed a method of precisely forming surfaces from brain contours. The method expresses the brain surface as the sum of several partial surfaces. Each partial surface is individually constructed from respective parts of brain contours. The brain surface is finally made up of a superposition of partial surfaces. Two surface formation algorithms based on this principle are presented. One expresses the brain surface as the sum of a brain outline surface and sulcus surfaces. The other expresses the brain surface as the sum of surfaces in the same part of the brain. The effectiveness of these algorithms is shown by evaluation of contours obtained from dog and human brain samples and CT images. The latter algorithm is shown to be superior for high-resolution CT images. Optional cut-away views of the brain constructed by these algorithms are also shown. (author)

  15. Chitosan inhibits platelet-mediated clot retraction, increases platelet-derived growth factor release, and increases residence time and bioactivity of platelet-rich plasma in vivo.

    Science.gov (United States)

    Deprés-Tremblay, Gabrielle; Chevrier, Anik; Tran-Khanh, Nicolas; Nelea, Monica; Buschmann, Michael D

    2017-11-10

    Platelet-rich plasma (PRP) has been used to treat different orthopedic conditions, however, the clinical benefits of using PRP remain uncertain. Chitosan (CS)-PRP implants have been shown to improve meniscus, rotator cuff and cartilage repair in pre-clinical models. The purpose of this current study was to investigate in vitro and in vivo mechanisms of action of CS-PRP implants. Freeze-dried formulations containing 1% (w/v) CS (80% degree of deacetylation and number average molar mass 38 kDa), 1% (w/v) trehalose as a lyoprotectant and 42.2 mM calcium chloride as a clot activator were solubilized in PRP. Gravimetric measurements and molecular/cellular imaging studies revealed that clot retraction is inhibited in CS-PRP hybrid clots through physical coating of platelets, blood cells and fibrin strands by chitosan, which interferes with platelet aggregation and platelet-mediated clot retraction. Flow cytometry and ELISA assays revealed that platelets are activated and granules secreted in CS-PRP hybrid clots and that cumulative release of platelet-derived growth factor (PDGF-AB) and epidermal growth factor is higher from CS-PRP hybrid clots compared to PRP clots in vitro. Finally, CS-PRP implants resided for up to 6 weeks in a subcutaneous implantation model and induced cell recruitment and granulation tissue synthesis, confirming greater residency and bioactivity compared to PRP in vivo.

  16. RESULTS OF QUALITY COMPREHENSIVE EVALUATION OF DENTAL CARE FOR CHILDREN WITH BLOOD CLOTTING (PATHOLOGY

    Directory of Open Access Journals (Sweden)

    M. A. Gavrilenko

    2014-04-01

    Full Text Available Background. Treatment methods for diseases of teeth hard tissues and periodontium for children with blood clotting pathology are described in modern literature. But in practice we are faced with the problem of providing dental treatment for these children. Work of pediatric dentist is prevented by the risk of bleeding, fear of dental procedures, child’s psychoemotional tension and refusal of treatment because of bleeding. Taking into account the specificity of blood clotting pathology, surgical methods of dental treatment prevail for these children, which is evidenced by the early loss of deciduous and permanent teeth, occlusal surface disturbances, dentoalveolar anomalies, inflammatory diseases of periodontal tissues. Aim. To evaluate the level of dental care for children with the diseases of blood clotting. Materials and methods. 120 children between 2 and 18 years old with blood clotting disorders (hemophilia A, B, thrombocytopenia, thrombocytopathy were examined. Children were divided into groups: I group – 2-5 years old (40 children, II group – 6-10 years old (40 children, III group – 11-18 years old (40 children, according to the periods of tooth development, with an equal number of children in groups according to diagnoses. Clinical examination was carried out according to the standard scheme, including the analysis of complaints, anamnesis of treatment at the dentist, objective data with the use of statistical method of masticatory efficiency (according to N.I. Agapov, the level of dental care (according to P.A. Leus. Results. During clinical dental examination of children with blood clotting pathology it was found that destruction of crowns of maxillary front teeth, the first deciduous molars and the second deciduous molars, as well as their loss, prevails in the temporary occlusion. During the examination of 2-5 years old children with blood clotting pathology, loss of less than 25% of masticatory efficiency was revealed for 25

  17. Monitoring of the Formation and Development Process for Infection and Inflammation Using F-18 FDG, PET/CT

    Directory of Open Access Journals (Sweden)

    Türkan Ertay

    2015-02-01

    Full Text Available Objective: Many radiopharmaceuticals have been evaluated extensively in both preclinical and clinical studies as potential diagnostic agents to identify the sites of infection. There is a definite role of FDG-PET in diagnosis, extent of assessing the disease, evaluation of treatment response and disease activity in patients with infections and inflammation. The aim of the study, the process of formation and development of infection and inflammation is monitored using (18 F 2’-deoxy-2-fluoroD-glucose (F-18 FDG by Positron Emission Computed Tomography (PET-CT. Methods: In this study, sterile abscess was induced by using turpentine and infected abscess was induced by using Staphylococcus aureus atcc 25923 strain on rats. In the abscess formation on rats, three grups rats were used as sterile, infected and control grups. There were examined male White Wistar Rats, the clinical healthy animals were 150-220 gr body weight. Bacterial strain and rat model for abscess formation for infected abscess formation on rats (n=7, S. aureus 0.5 ml 107 CFU/ml was inoculated in the right arm of the rats as subcutaneous. For sterile abscess formation on rats (n=7 0.2-0.4 ml turpentine (sigma-aldrich was injected into the right arm of the rats as subcutaneous. In control group (n=6, 0.5 ml 0.9% NaCl was injected into the right arm of the rats as subcutaneous. First day imsaging was acquired 24 hours after inoculation of S.aureus and turpentine. 1 mCi 18F-FDG was injected intravenously via the tail vein. Prior to 18F-FDG injection, rats fasted at least 4 hours and well hydrated. Imaging was done using PET-CT (PHILIPS Gemini TF, beginning 1 hour following injection of 18F-FDG IV in the first day and at intervals of 24 hours for five days. First day imaging was performed 1. hour after IV injection of 18F-FDG to obtain optimum imaging time. PET/CT images were visually and semiquantitatively assessed. For semiquantitative analysis of the PET images, a region of interest

  18. Incorporation of vitronectin into fibrin clots. Evidence for a binding interaction between vitronectin and gamma A/gamma' fibrinogen.

    Science.gov (United States)

    Podor, Thomas J; Campbell, Stephanie; Chindemi, Paul; Foulon, Denise M; Farrell, David H; Walton, Philip D; Weitz, Jeffrey I; Peterson, Cynthia B

    2002-03-01

    Vitronectin is an abundant plasma protein that regulates coagulation, fibrinolysis, complement activation, and cell adhesion. Recently, we demonstrated that plasma vitronectin inhibits fibrinolysis by mediating the interaction of type 1 plasminogen activator inhibitor with fibrin (Podor, T. J., Peterson, C. B., Lawrence, D. A., Stefansson, S., Shaughnessy, S. G., Foulon, D. M., Butcher, M., and Weitz, J. I. (2000) J. Biol. Chem. 275, 19788-19794). The current studies were undertaken to further examine the interactions between vitronectin and fibrin(ogen). Comparison of vitronectin levels in plasma with those in serum indicates that approximately 20% of plasma vitronectin is incorporated into the clot. When the time course of biotinylated-vitronectin incorporation into clots formed from (125)I-fibrinogen is monitored, vitronectin incorporation into the clot parallels that of fibrinogen in the absence or presence of activated factor XIII. Vitronectin binds specifically to fibrin matrices with an estimated K(d) of approximately 0.6 microm. Additional vitronectin subunits are assembled on fibrin-bound vitronectin multimers through self-association. Confocal microscopy of fibrin clots reveals the globular vitronectin aggregates anchored at intervals along the fibrin fibrils. This periodicity raised the possibility that vitronectin interacts with the gamma A/gamma' variant of fibrin(ogen) that represents about 10% of total fibrinogen. In support of this concept, the vitronectin which contaminates fibrinogen preparations co-purifies with the gamma A/gamma' fibrinogen fraction, and clots formed from gamma A/gamma' fibrinogen preferentially bind vitronectin. These studies reveal that vitronectin associates with fibrin during coagulation, and may thereby modulate hemostasis and inflammation.

  19. Effects of calcium binding and of EDTA and CaEDTA on the clotting of bovine fibrinogen by thrombin.

    Science.gov (United States)

    Perizzolo, K E; Sullivan, S; Waugh, D F

    1985-03-01

    Studies were carried out at pH 7.0 and gamma/2 0.15 before addition of CaCl2 or EDTA. Clotting time, tau, at 3.03 microM fibrinogen and 0.91 u/ml thrombin was determined for equilibrium systems. With added Ca2+, tau decreases, from tau 0 at 0 added Ca2+ (mean, 29.7 +/- 3 s), by approximately 3 s at 5 mM added Ca2+. With added EDTA, tau increases sigmoidally from tau 0 at 0 EDTA to a maximum (mean tau m = 142 +/- 23 s) at approximately 200 microM EDTA. tau then decreases slightly to a minimum at approximately 1.3 mM and finally increases to infinity at approximately 10 mM EDTA. Between 0 and 1.3 mM EDTA, effects on clotting time are completely reversed by adding Ca2+ and, after equilibration at 400 microM EDTA, tau is independent of EDTA concentration. Thus, up to 400 microM EDTA, effects on clotting time are attributed to decreasing fibrinogen bound Ca2+. Between 5 mM Ca2+ and 200 microM EDTA it is assumed that an equilibrium distribution of fibrinogen species having 3, 2, 1, or 0 bound calcium ions is established and that a clotting time is determined by the sum of products of species fractional abundance and pure species clotting time. Analysis indicates that pure species clotting times increase proportionately with decreasing Ca2+ binding, binding sites are nearly independent, and the microscopic association constant for the first bound Ca2+ is approximately 4.9 X 10(6) M-1. Effects of adding Ca2+ at times t1 after thrombin addition to systems initially equilibrated at 200 microM EDTA were determined. Analysis of the relation between tau and t1 indicates that as Ca2+ binding decreases, rate constants for release of B peptides decrease less than those for release of A peptides. As EDTA concentration is increased above 1.3 mM, inhibitory effects of EDTA and CaEDTA progressively increase.

  20. 99mTc-NC100668, a new tracer for imaging venous thromboemboli: pre-clinical biodistribution and incorporation into plasma clots in vivo and in vitro

    International Nuclear Information System (INIS)

    Edwards, David; Lewis, Joanne; Battle, Mark; Lear, Rochelle; Farrar, Gill; Barnett, D.J.; Godden, Vanessa; Oliveira, Alexandra; Coombes, Catherine; Ahlstroem, Haakan

    2006-01-01

    99m Tc-NC100668 is a new radiotracer being developed to aid the diagnosis of thromboembolism. The structure of NC100668 is similar to a region of human α 2 -antiplasmin, which is a substrate for factor XIIIa (FXIIIa). The purpose of this study was to confirm the uptake of 99m Tc-NC100668 into forming plasma clot and to establish the biodistribution of 99m Tc-NC100668 in Wistar rats. The in vitro plasma clot uptake of 99m Tc-NC100668 and other compounds with known affinities to FXIIIa was measured using a plasma clot assay. The biodistribution and blood clot uptake of radioactivity of 99m Tc-NC100668 in normal Wistar rats and those bearing experimentally induced deep vein thrombi were investigated. The in vitro uptake of 99m Tc-NC100668 was greater than that for [ 14 C]dansyl cadaverine, a known substrate of FXIIIa in the plasma clot assay. The biodistribution of 99m Tc-NC100668 in male and female Wistar rats up to 24 h p.i. showed that radioactivity was rapidly excreted, predominantly into the urine, with very little background tissue retention. In vivo the uptake and retention of 99m Tc-NC100668 into the blood clot was greater than could be accounted for by non-specific accumulation of the radiotracer within the blood clot. 99m Tc-NC100668 was retained by plasma clots in vitro and blood clots in vivo. No significant tissue retention which could interfere with the ability to image thrombi in vivo was observed. This evidence suggests that 99m Tc-NC100668 might be useful in the detection of thromboembolism. (orig.)

  1. μCT-based, in vivo dynamic bone histomorphometry allows 3D evaluation of the early responses of bone resorption and formation to PTH and alendronate combination therapy.

    Science.gov (United States)

    de Bakker, Chantal M J; Altman, Allison R; Tseng, Wei-Ju; Tribble, Mary Beth; Li, Connie; Chandra, Abhishek; Qin, Ling; Liu, X Sherry

    2015-04-01

    Current osteoporosis treatments improve bone mass by increasing net bone formation: anti-resorptive drugs such as bisphosphonates block osteoclast activity, while anabolic agents such as parathyroid hormone (PTH) increase bone remodeling, with a greater effect on formation. Although these drugs are widely used, their role in modulating formation and resorption is not fully understood, due in part to technical limitations in the ability to longitudinally assess bone remodeling. Importantly, it is not known whether or not PTH-induced bone formation is independent of resorption, resulting in controversy over the effectiveness of combination therapies that use both PTH and an anti-resorptive. In this study, we developed a μCT-based, in vivo dynamic bone histomorphometry technique for rat tibiae, and applied this method to longitudinally track changes in bone resorption and formation as a result of treatment with alendronate (ALN), PTH, or combination therapy of both PTH and ALN (PTH+ALN). Correlations between our μCT-based measures of bone formation and measures of bone formation based on calcein-labeled histology (r=0.72-0.83) confirm the accuracy of this method. Bone remodeling parameters measured through μCT-based in vivo dynamic bone histomorphometry indicate an increased rate of bone formation in rats treated with PTH and PTH+ALN, together with a decrease in bone resorption measures in rats treated with ALN and PTH+ALN. These results were further supported by traditional histology-based measurements, suggesting that PTH was able to induce bone formation while bone resorption was suppressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Cloning, expression and characterization of a gene from earthworm Eisenia fetida encoding a blood-clot dissolving protein.

    Directory of Open Access Journals (Sweden)

    GangQiang Li

    Full Text Available A lumbrokinase gene encoding a blood-clot dissolving protein was cloned from earthworm (Eisenia fetida by RT-PCR amplification. The gene designated as CST1 (GenBank No. AY840996 was sequence analyzed. The cDNA consists of 888 bp with an open reading frame of 729 bp, which encodes 242 amino acid residues. Multiple sequence alignments revealed that CST1 shares similarities and conserved amino acids with other reported lumbrokinases. The amino acid sequence of CST1 exhibits structural features similar to those found in other serine proteases, including human tissue-type (tPA, urokinase (uPA, and vampire bat (DSPAα1 plasminogen activators. CST1 has a conserved catalytic triad, found in the active sites of protease enzymes, which are important residues involved in polypeptide catalysis. CST1 was expressed as inclusion bodies in Escherichia coli BL21(DE3. The molecular mass of recombinant CST1 (rCST was 25 kDa as estimated by SDS-PAGE, and further confirmed by Western Blot analysis. His-tagged rCST1 was purified and renatured using nickel-chelating resin with a recovery rate of 50% and a purity of 95%. The purified, renatured rCST1 showed fibrinolytic activity evaluated by both a fibrin plate and a blood clot lysis assay. rCST1 degraded fibrin on the fibrin plate. A significant percentage (65.7% of blood clot lysis was observed when blood clot was treated with 80 mg/mL of rCST1 in vitro. The antithrombotic activity of rCST1 was 912 units/mg calculated by comparison with the activity of a lumbrokinase standard. These findings indicate that rCST1 has potential as a potent blood-clot treatment. Therefore, the expression and purification of a single lumbrokinase represents an important improvement in the use of lumbrokinases.

  3. Staphylococcus chromogenes, a Coagulase-Negative Staphylococcus Species That Can Clot Plasma

    OpenAIRE

    dos Santos, Danielle Cabral; Lange, Carla Christine; Avellar-Costa, Pedro; dos Santos, Katia Regina Netto; Brito, Maria Aparecida Vasconcelos Paiva; Giambiagi-deMarval, Marcia

    2016-01-01

    Staphylococcus chromogenes is one of the main coagulase-negative staphylococci isolated from mastitis of dairy cows. We describe S. chromogenes isolates that can clot plasma. Since the main pathogen causing mastitis is coagulase-positive Staphylococcus aureus, the coagulase-positive phenotype of S. chromogenes described here can easily lead to misidentification.

  4. Multidetector CT: a new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Piva, Tommaso; Lovato, Luigi; Fattori, Rossella; Gavelli, Giampaolo

    2005-01-01

    Purpose: From the early 90s, spiral CT technology has considerably changed the diagnostic capability of Pulmonary Embolism (PE), giving a direct vision of intravascular thrombi. Further technological progress has straightened its diagnostic impact leading to an essential role in clinical practice. The advent of Multi-Detector CT (MDCT) has subsequently increased the reliability of this technique to the point of undermining the role of pulmonary angiography as the gold standard and occupying a central position in diagnostic algorithms. The aim of this paper is to appraise this evolution by means of a meta-analysis of the relevant literature from 1995 to 2004. Results: The review of the literature showed the sensitivity and specificity of CT to have increased from 37-94% and 91-100% (single detector CT) to 87-94% and 94-100% (4-channel multidetector CT), especially thanks to the possibility of depicting subsegmental clots, with an interobserver agreement of 0.63-0.94 (k). Conclusions: CT is one of the most reliable and effective methods in the diagnosis is PE, with the advantage of being extremely fast and providing alternative diagnoses. Recent improvements in MDCT technology confers the highest value of diagnostic accuracy with respect to other imaging modalities such as scintigraphy, angiography, MRI, D-dimer essay and Doppler US [it

  5. Lung cancer mimicking lung abscess formation on CT images

    OpenAIRE

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Patient: Male, 64 Final Diagnosis: Lung pleomorphic carcinoma Symptoms: Cough • fever Medication: — Clinical Procedure: — Specialty: Oncology Objective: Unusual clinical course Background: The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resemble...

  6. Staphylococcus chromogenes, a Coagulase-Negative Staphylococcus Species That Can Clot Plasma

    Science.gov (United States)

    dos Santos, Danielle Cabral; Lange, Carla Christine; Avellar-Costa, Pedro; dos Santos, Katia Regina Netto; Brito, Maria Aparecida Vasconcelos Paiva

    2016-01-01

    Staphylococcus chromogenes is one of the main coagulase-negative staphylococci isolated from mastitis of dairy cows. We describe S. chromogenes isolates that can clot plasma. Since the main pathogen causing mastitis is coagulase-positive Staphylococcus aureus, the coagulase-positive phenotype of S. chromogenes described here can easily lead to misidentification. PMID:26912749

  7. Effects of temperature on bleeding time and clotting time in normal male and female volunteers.

    Science.gov (United States)

    Valeri, C R; MacGregor, H; Cassidy, G; Tinney, R; Pompei, F

    1995-04-01

    This study was done to assess the effects of temperature on bleeding time and clotting time in normal male and female volunteers. Open study utilizing normal volunteers. University research laboratory. Fifty-four healthy male and female volunteers, ranging in age from 19 to 35 yrs, who were not receiving medications. The study was done and the samples of venous blood and shed blood collected at the template bleeding time site were obtained at a convenient time for each volunteer. Skin temperature was changed from +20 degrees to +38 degrees C and blood samples were obtained from the antecubital vein of each volunteer. The effect of local skin temperature ranging from +20 degrees to +38 degrees C on bleeding time was evaluated in 38 normal volunteers (19 male and 19 female). Skin temperature was maintained at +20 degrees to +38 degrees C by cooling or warming the forearm. At each temperature, measurements were made of complete blood count, bleeding time, and thromboxane B2 concentrations in shed blood collected at the template bleeding time site and in serum and plasma isolated from blood collected from the antecubital vein. Clotting time studies were measured in 16 normal volunteers (eight male and eight female) at temperatures ranging from +22 degrees to +37 degrees C. At +32 degrees C, the bleeding time was longer and hematocrit was lower in female than in male volunteers. However, at local skin temperatures of < +32 degrees C, both the males and females exhibited significantly increased bleeding times, which were associated with a reduction in shed blood thromboxane B2. Each 1 degree C decrease in temperature was associated with a 15% decrease in the shed blood thromboxane B2 concentration. Clotting times were three times longer at +22 degrees C than at +37 degrees C. Each 1 degree C reduction in the temperature of the clotted blood was associated with a 15% reduction in the serum thromboxane B2 concentration. Our data indicate that during surgical procedures, it

  8. Real-time monitoring of human blood clotting using a lateral excited film bulk acoustic resonator

    Science.gov (United States)

    Chen, Da; Wang, Jingjng; Wang, Peng; Guo, Qiuquan; Zhang, Zhen; Ma, Jilong

    2017-04-01

    Frequent assay of hemostatic status is an essential issue for the millions of patients using anticoagulant drugs. In this paper, we presented a micro-fabricated film bulk acoustic sensor for the real-time monitoring of blood clotting and the measurement of hemostatic parameters. The device was made of an Au/ZnO/Si3N4 film stack and excited by a lateral electric field. It operated under a shear mode resonance with the frequency of 1.42 GHz and had a quality factor of 342 in human blood. During the clotting process of blood, the resonant frequency decreased along with the change of blood viscosity and showed an apparent step-ladder curve, revealing the sequential clotting stages. An important hemostatic parameter, prothrombin time, was quantitatively determined from the frequency response for different dilutions of the blood samples. The effect of a typical anticoagulant drug (heparin) on the prothrombin time was exemplarily shown. The proposed sensor displayed a good consistency and clinical comparability with the standard coagulometric methods. Thanks to the availability of direct digital signals, excellent potentials of miniaturization and integration, the proposed sensor has promising application for point-of-care coagulation technologies.

  9. {sup 99m}Tc-NC100668, a new tracer for imaging venous thromboemboli: pre-clinical biodistribution and incorporation into plasma clots in vivo and in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, David [Grove Centre, Research and Development, GE Healthcare Bio-Sciences, Little Chalfont (United Kingdom); Uppsala University Hospital, Institution of Oncology, Radiology and Clinical Immunology, Section of Radiology, Uppsala (Sweden); Lewis, Joanne; Battle, Mark; Lear, Rochelle; Farrar, Gill; Barnett, D.J.; Godden, Vanessa; Oliveira, Alexandra; Coombes, Catherine [Grove Centre, Research and Development, GE Healthcare Bio-Sciences, Little Chalfont (United Kingdom); Ahlstroem, Haakan [Uppsala University Hospital, Institution of Oncology, Radiology and Clinical Immunology, Section of Radiology, Uppsala (Sweden)

    2006-11-15

    {sup 99m}Tc-NC100668 is a new radiotracer being developed to aid the diagnosis of thromboembolism. The structure of NC100668 is similar to a region of human {alpha}{sub 2}-antiplasmin, which is a substrate for factor XIIIa (FXIIIa). The purpose of this study was to confirm the uptake of {sup 99m}Tc-NC100668 into forming plasma clot and to establish the biodistribution of {sup 99m}Tc-NC100668 in Wistar rats. The in vitro plasma clot uptake of {sup 99m}Tc-NC100668 and other compounds with known affinities to FXIIIa was measured using a plasma clot assay. The biodistribution and blood clot uptake of radioactivity of {sup 99m}Tc-NC100668 in normal Wistar rats and those bearing experimentally induced deep vein thrombi were investigated. The in vitro uptake of {sup 99m}Tc-NC100668 was greater than that for [{sup 14}C]dansyl cadaverine, a known substrate of FXIIIa in the plasma clot assay. The biodistribution of {sup 99m}Tc-NC100668 in male and female Wistar rats up to 24 h p.i. showed that radioactivity was rapidly excreted, predominantly into the urine, with very little background tissue retention. In vivo the uptake and retention of {sup 99m}Tc-NC100668 into the blood clot was greater than could be accounted for by non-specific accumulation of the radiotracer within the blood clot. {sup 99m}Tc-NC100668 was retained by plasma clots in vitro and blood clots in vivo. No significant tissue retention which could interfere with the ability to image thrombi in vivo was observed. This evidence suggests that {sup 99m}Tc-NC100668 might be useful in the detection of thromboembolism. (orig.)

  10. Characteristic CT signs in oligodendrogliomas

    International Nuclear Information System (INIS)

    Marcu, H.; Vonofakos, D.; Hacker, H.

    1980-01-01

    Computed tomography offers valuable aid for improving the diagnostic capabilities for oligodendrogliomas. The authors have attempted to determine more precisely the CT characteristic signs for this type of tumor and to establish criteria for predicting malignancy grade. They can conclude that calcifications are the main signs which lead to the diagnosis of oligodendroglioma, as the most usual calcifying glioma. This finding was known before the CT era, but with the CT one can be more exact with regard to form, growth, number and density of the calcifications and especially the smallest of them, which are not to be seen on the conventional X-ray examination. The cyst formation is another feature of oligodendroglioma. The occurrence of contrast enhancement and cyst formation are the most characteristic signs of malignancy. (C.F.)

  11. Application of actuator-driven pulsed water jet in aneurysmal subarachnoid hemorrhage surgery: its effectiveness for dissection around ruptured aneurysmal walls and subarachnoid clot removal.

    Science.gov (United States)

    Endo, Hidenori; Endo, Toshiki; Nakagawa, Atsuhiro; Fujimura, Miki; Tominaga, Teiji

    2017-07-01

    In clipping surgery for aneurysmal subarachnoid hemorrhage (aSAH), critical steps include clot removal and dissection of aneurysms without premature rupture or brain injuries. To pursue this goal, a piezo actuator-driven pulsed water jet (ADPJ) system was introduced in this study. This study included 42 patients, who suffered aSAH and underwent clipping surgery. Eleven patients underwent surgery with the assistance of the ADPJ system (ADPJ group). In the other 31 patients, surgery was performed without the ADPJ system (Control group). The ADPJ system was used for clot removal and aneurysmal dissection. The clinical impact of the ADPJ system was judged by comparing the rate of premature rupture, degree of clot removal, and clinical outcomes. Intraoperatively, a premature rupture was encountered in 18.2 and 25.8% of cases in the ADPJ and control groups, respectively. Although the differences were not statistically significant, intraoperative observation suggested that the ADPJ system was effective in clot removal and dissection of aneurysms in a safe manner. Computed tomography scans indicated the achievement of higher degrees of clot removal, especially when the ADPJ system was used for cases with preoperative clot volumes of more than 25 ml (p = 0.047, Mann-Whitney U test). Clinical outcomes, including incidence of postoperative brain injury or symptomatic vasospasm, were similar in both groups. We described our preliminary surgical results using the ADPJ system for aSAH. Although further study is needed, the ADPJ system was considered a safe and effective tool for clot removal and dissection of aneurysms.

  12. Lung infarction following pulmonary embolism. A comparative study on clinical conditions and CT findings to identify predisposing factors

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, J.; Obermann, A.; Stueckradt, S.; Tueshaus, C. [General Hospital Hagen (Germany). Radiology; Goltz, J.; Kickuth, R. [University Hospital Wuerzburg (Germany). Radiology; Liermann, D. [University Hospital Marienhospital Herne (Germany). Radiology

    2015-06-15

    The aim of this study was to identify factors predisposing to lung infarction in patients with pulmonary embolism (PE). We performed a retrospective analysis on 154 patients with the final diagnosis of PE being examined between January 2009 and December 2012 by means of a Toshiba Aquilion 64 CT scanner. The severity of clinical symptoms was defined by means of a clinical index with 4 classes. The pulmonary clot load was quantified using a modified severity index of PE as proposed by Miller. We correlated several potential predictors of pulmonary infarction such as demographic data, pulmonary clot burden, distance of total vascular obstruction and pleura, the presence of cardiac congestion, signs of chronic bronchitis or emphysema with the occurrence of pulmonary infarction. Computed tomography revealed 78 areas of pulmonary infarction in 45/154 (29.2%) patients. The presence of infarction was significantly higher in the right lung than in the left lung (p < 0.001). We found no correlation between pulmonary infarction and the presence of accompanying malignant diseases (r=-0.069), signs of chronic bronchitis (r=-0.109), cardiac congestion (r=-0.076), the quantified clot burden score (r=0.176), and the severity of symptoms (r=-0.024). Only a very weak negative correlation between the presence of infarction and age (r=-0.199) was seen. However, we could demonstrate a moderate negative correlation between the distance of total vascular occlusion and the occurrence of infarction (r=-0.504). Neither cardiac congestion nor the degree of pulmonary vascular obstruction are main factors predisposing to pulmonary infarction in patients with PE. It seems that a peripheral total vascular obstruction more often results in infarction than even massive central clot burden.

  13. Platelet microparticle-inspired clot-responsive nanomedicine for targeted fibrinolysis.

    Science.gov (United States)

    Pawlowski, Christa L; Li, Wei; Sun, Michael; Ravichandran, Kavya; Hickman, DaShawn; Kos, Clarissa; Kaur, Gurbani; Sen Gupta, Anirban

    2017-06-01

    Intravascular administration of plasminogen activators is a clinically important thrombolytic strategy to treat occlusive vascular conditions. A major issue with this strategy is the systemic off-target drug action, which affects hemostatic capabilities and causes substantial hemorrhagic risks. This issue can be potentially resolved by designing technologies that allow thrombus-targeted delivery and site-specific action of thrombolytic drugs. To this end, leveraging a liposomal platform, we have developed platelet microparticle (PMP)-inspired nanovesicles (PMINs), that can protect encapsulated thrombolytic drugs in circulation to prevent off-target uptake and action, anchor actively onto thrombus via PMP-relevant molecular mechanisms and allow drug release via thrombus-relevant enzymatic trigger. Specifically, the PMINs can anchor onto thrombus via heteromultivalent ligand-mediated binding to active platelet integrin GPIIb-IIIa and P-selectin, and release the thrombolytic payload due to vesicle destabilization triggered by clot-relevant enzyme phospholipase-A 2 . Here we report on the evaluation of clot-targeting efficacy, lipase-triggered drug release and resultant thrombolytic capability of the PMINs in vitro, and subsequently demonstrate that intravenous delivery of thrombolytic-loaded PMINs can render targeted fibrinolysis without affecting systemic hemostasis, in vivo, in a carotid artery thrombosis model in mice. Our studies establish significant promise of the PMIN technology for safe and site-targeted nanomedicine therapies in the vascular compartment. Copyright © 2017. Published by Elsevier Ltd.

  14. Clotting of cow (Bos taurus) and goat milk ( Capra hircus ) using ...

    African Journals Online (AJOL)

    The ease to locally produce kid rennet contrary to that of calve has led us to compare the proteolytic and clotting activities of these two rennets depending on their action on goat (Capra hircus) milk and cow (Bos taurus) milk. The proteolysis was measured by determining the increase of non-protein nitrogen according to the ...

  15. Clot retraction is mediated by factor XIII-dependent fibrin-αIIbβ3-myosin axis in platelet sphingomyelin-rich membrane rafts.

    Science.gov (United States)

    Kasahara, Kohji; Kaneda, Mizuho; Miki, Toshiaki; Iida, Kazuko; Sekino-Suzuki, Naoko; Kawashima, Ikuo; Suzuki, Hidenori; Shimonaka, Motoyuki; Arai, Morio; Ohno-Iwashita, Yoshiko; Kojima, Soichi; Abe, Mitsuhiro; Kobayashi, Toshihide; Okazaki, Toshiro; Souri, Masayoshi; Ichinose, Akitada; Yamamoto, Naomasa

    2013-11-07

    Membrane rafts are spatially and functionally heterogenous in the cell membrane. We observed that lysenin-positive sphingomyelin (SM)-rich rafts are identified histochemically in the central region of adhered platelets where fibrin and myosin are colocalized on activation by thrombin. The clot retraction of SM-depleted platelets from SM synthase knockout mouse was delayed significantly, suggesting that platelet SM-rich rafts are involved in clot retraction. We found that fibrin converted by thrombin translocated immediately in platelet detergent-resistant membrane (DRM) rafts but that from Glanzmann's thrombasthenic platelets failed. The fibrinogen γ-chain C-terminal (residues 144-411) fusion protein translocated to platelet DRM rafts on thrombin activation, but its mutant that was replaced by A398A399 at factor XIII crosslinking sites (Q398Q399) was inhibited. Furthermore, fibrin translocation to DRM rafts was impaired in factor XIII A subunit-deficient mouse platelets, which show impaired clot retraction. In the cytoplasm, myosin translocated concomitantly with fibrin translocation into the DRM raft of thrombin-stimulated platelets. Furthermore, the disruption of SM-rich rafts by methyl-β-cyclodextrin impaired myosin activation and clot retraction. Thus, we propose that clot retraction takes place in SM-rich rafts where a fibrin-αIIbβ3-myosin complex is formed as a primary axis to promote platelet contraction.

  16. Two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan

    International Nuclear Information System (INIS)

    Fuwa, Isao; Matsukado, Yasuhiko; Otsuka, Tadahiro; Kodama, Takafumi; Wada, Hidetaka.

    1985-01-01

    We describe two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan. The first case was a 53-year-old woman who presented progressive motor difficulty and mental disturbance. A CT scan showed a large, round, high-density area with a clear margin in the right temporal and paraventricular regions. A low-density area extended around the large high-density lesion, and the ventricular system was shifted to the contralateral side. A thrombosed giant aneurysm with significant brain edema was confirmed surgically. The second case was a 66-year-old woman who had a history of severe headache and vomiting. A CT scan showed a ring-like calcification located in the right basal ganglia. A cystic low density, which compressed the right anterior horn, was observed in the right frontal region. Right carotid angiography revealed an aneurysm arising from the M 1 portion. The patient died before surgical intervention; however, neuroradiological examination indicated a liquefied clot in the thrombosed giant aneurysm. The etiology of the unusual low density was discussed in relation to the CT findings of the giant aneurysm. (author)

  17. Two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Isao; Matsukado, Yasuhiko; Otsuka, Tadahiro; Kodama, Takafumi; Wada, Hidetaka

    1985-12-01

    We describe two cases of thrombosed giant middle cerebral aneurysms presenting an unusual low-density area on a CT scan. The first case was a 53-year-old woman who presented progressive motor difficulty and mental disturbance. A CT scan showed a large, round, high-density area with a clear margin in the right temporal and paraventricular regions. A low-density area extended around the large high-density lesion, and the ventricular system was shifted to the contralateral side. A thrombosed giant aneurysm with significant brain edema was confirmed surgically. The second case was a 66-year-old woman who had a history of severe headache and vomiting. A CT scan showed a ring-like calcification located in the right basal ganglia. A cystic low density, which compressed the right anterior horn, was observed in the right frontal region. Right carotid angiography revealed an aneurysm arising from the M/sub 1/ portion. The patient died before surgical intervention; however, neuroradiological examination indicated a liquefied clot in the thrombosed giant aneurysm. The etiology of the unusual low density was discussed in relation to the CT findings of the giant aneurysm.

  18. Factors Affecting the Growth and Production of Milk-Clotting Enzyme by Amylomyces rouxii in Rice Liquid Medium

    Directory of Open Access Journals (Sweden)

    Pei-Jing Yu

    2005-01-01

    Full Text Available Amylomyces rouxii is one of the main fungi usually coexisting with yeasts in Chinese yeast ball, the starter of chiu-niang, a traditional Chinese fermented product from rice. In the present study, growth and production of milk-clotting enzyme (MCE in gelatinous rice liquid culture of A. rouxii as influenced by waxy (gelatinous rice content in the medium (5–20 %, temperature (25–40 °C, cultivation time (1–6 days, shaking speeds (0–150 rpm and metal ions (Na+, K+, Zn2+, Mg2+, Mn2+, Cu2+, Ca2+, Fe3+ and Al3+ were investigated. Results revealed that rice content in the medium, shaking speed, temperature and cultivation time all affected the mycelial propagation and the production of milk-clotting enzyme by A. rouxii in the rice liquid culture. The maximum milk-clotting enzyme activity of ca. 1.22 unit/mL of medium was observed in the 3-day static culture of test organism grown at 30 °C in the medium containing 20 % of gelatinous rice, while mycelial propagation increased with the increase of cultivation time and shaking speed. Furthermore, a significant increase (p<0.05 in the milk-clotting enzyme activity of ca. 1.90 unit/mL of medium, which was about 1.55-fold of the control, was observed when Al3+ was added to the rice liquid medium.

  19. Googling Service Boundaries for Endovascular Clot Retrieval Hub Hospitals in a Metropolitan Setting: Proof-of-Concept Study.

    Science.gov (United States)

    Phan, Thanh G; Beare, Richard; Chen, Jian; Clissold, Benjamin; Ly, John; Singhal, Shaloo; Ma, Henry; Srikanth, Velandai

    2017-05-01

    There is great interest in how endovascular clot retrieval hubs provide services to a population. We applied a computational method to objectively generate service boundaries for such endovascular clot retrieval hubs, defined by traveling time to hub. Stroke incidence data merged with population census to estimate numbers of stroke in metropolitan Melbourne, Australia. Traveling time from randomly generated addresses to 4 endovascular clot retrieval-capable hubs (Royal Melbourne Hospital [RMH], Monash Medical Center [MMC], Alfred Hospital [ALF], and Austin Hospital [AUS]) estimated using Google Map application program interface. Boundary maps generated based on traveling time at various times of day for combinations of hubs. In a 2-hub model, catchment was best distributed when RMH was paired with MMC (model 1a, RMH 1765 km 2 and MMC 1164 km 2 ) or with AUS (model 1c, RMH 1244 km 2 and AUS 1685 km 2 ), with no statistical difference between models ( P =0.20). Catchment was poorly distributed when RMH was paired with ALF (model 1b, RMH 2252 km 2 and ALF 676 km 2 ), significantly different from both models 1a and 1c (both P AUS was superior to that of RMH, MMC, and ALF in catchment distribution and travel time. The method was also successfully applied to the city of Adelaide demonstrating wider applicability. We provide proof of concept for a novel computational method to objectively designate service boundaries for endovascular clot retrieval hubs. © 2017 American Heart Association, Inc.

  20. Comparison of standard fibrinogen measurement methods with fibrin clot firmness assessed by thromboelastometry in patients with cirrhosis.

    Science.gov (United States)

    Vucelic, Dragica; Jesic, Rada; Jovicic, Snezana; Zivotic, Maja; Grubor, Nikica; Trajkovic, Goran; Canic, Ivana; Elezovic, Ivo; Antovic, Aleksandra

    2015-06-01

    The Clauss fibrinogen method and thrombin clotting time (TCT) are still routinely used in patients with cirrhosis to define fibrinogen concentration and clotting potential. The thromboelastometric functional fibrinogen FIBTEM assay evaluates the strength of fibrin-based clots in whole blood, providing information on both quantitative deficit and fibrin polymerization disorders. To compare these three methods of assessing fibrinogen in patients with cirrhosis of different aetiologies, characterized by impairment in fibrinogen concentration as well as functional aberrance. Sixty patients with alcoholic and 24 patients with cholestatic cirrhosis were included (Child-Pugh score (CPs)A, n=24; B, n=32; C, n=28). All parameters were compared with those from a control group. Maximum clot firmness (MCF) in the FIBTEM test was assessed in regard to its relevance in detection of qualitative fibrinogen disorders in comparison with results obtained by standard measurement methods, i.e. the Clauss fibrinogen method and TCT. With increased cirrhosis severity, fibrinogen and FIBTEM-MCF levels significantly declined (p=0.002), while TCT was significantly prolonged (p=0.002). In all CPs groups, fibrinogen strongly correlated with FIBTEM-MCF (r=0.77, r=0.72, r=0.74; pmeasurement in cirrhotic patients, especially in evaluating fibrin polymerization disorders in these patients. Further studies are needed to evaluate the usefulness of this assay in predicting bleeding complications in cirrhotic patients as well as monitoring replacement treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Production of milk-clotting enzyme by Bacillus subtilis B1 from wheat ...

    African Journals Online (AJOL)

    Three strains, Bacillus subtilis B1, B. subtilis B18 and Bacillus thuringiensis B12, were screened from wheat bran to produce milk-clotting enzyme. Among them, B. subtilis B1 exhibited considerable milkclotting activity with low proteolytic activity. After response surface methodology optimization, milkclotting activity was ...

  2. Extrapulmonary colony formation after intravenous injection of tumour cells into heparin treated animals

    NARCIS (Netherlands)

    Maat, B.

    1978-01-01

    Recent data on extrapulmonary colony formation after heparin administration are inconclusive. A systemic study of this topic was undertaken with 4 experimental tumour systems and 2 distinct periods of reduced clotting capacity in rats and mice. I.v. injection of various numbers of tumour cells into

  3. Clot lysis time in platelet-rich plasma: method assessment, comparison with assays in platelet-free and platelet-poor plasmas, and response to tranexamic acid.

    Science.gov (United States)

    Panes, Olga; Padilla, Oslando; Matus, Valeria; Sáez, Claudia G; Berkovits, Alejandro; Pereira, Jaime; Mezzano, Diego

    2012-01-01

    Fibrinolysis dysfunctions cause bleeding or predisposition to thrombosis. Platelets contain several factors of the fibrinolytic system, which could up or down regulate this process. However, the temporal relationship and relative contributions of plasma and platelet components in clot lysis are mostly unknown. We developed a clot lysis time (CLT) assay in platelet-rich plasma (PRP-CLT, with and without stimulation) and compared it to a similar one in platelet-free plasma (PFP) and to another previously reported test in platelet-poor plasma (PPP). We also studied the differential effects of a single dose of tranexamic acid (TXA) on these tests in healthy subjects. PFP- and PPP-CLT were significantly shorter than PRP-CLT, and the three assays were highly correlated (p plasma PAI-1, von Willebrand factor, fibrinogen, LDL-cholesterol, and triglycerides (p platelet aggregation/secretion, platelet counts, and pro-coagulant tests to explore factor X activation by platelets, PRP clotting time, and thrombin generation in PRP. Among all the studied variables, PFP-CLT was independently associated with plasma PAI-1, LDL-cholesterol, and triglycerides and, additionally, stimulated PRP-CLT was also independently associated with plasma fibrinogen. A single 1 g dose of TXA strikingly prolonged all three CLTs, but in contrast to the results without the drug, the lysis times were substantially shorter in non-stimulated or stimulated PRP than in PFP and PPP. This standardized PRP-CLT may become a useful tool to study the role of platelets in clot resistance and lysis. Our results suggest that initially, the platelets enmeshed in the clot slow down the fibrinolysis process. However, the increased clot resistance to lysis induced by TXA is overcome earlier in platelet-rich clots than in PFP or PPP clots. This is likely explained by the display of platelet pro-fibrinolytic effects. Focused research is needed to disclose the mechanisms for the relationship between CLT and plasma

  4. Travail et pouvoir d’agir d’Yves Clot

    Directory of Open Access Journals (Sweden)

    Jacques Leplat

    2008-11-01

    Full Text Available Yves Clot est titulaire de la Chaire de psychologie du travail du Conservatoire National des Arts et Métiers (CNAM au sein duquel il dirige l’équipe de clinique de l’activité. Cet ouvrage est le second qu’il publie dans cette collection, le premier « La fonction psychologique du travail » est paru en 1999. Entre les deux s’inscrivent un grand nombre de publications, dont beaucoup avec d’autres chercheurs, comme on pourra le constater en consultant la bibliographie de ce livre. Ce denier réun...

  5. Effects of neutron-gamma or gamma irradiations on plasma clotting factors. Effect of a treatment by substituted factors

    International Nuclear Information System (INIS)

    Mestries, J.C.; Martin, S.; Janodet, D.; Herodin, F.; Gourmelon, P.; Fatome, M.

    1991-01-01

    Neutron-gamma irradiation of the baboon at lethal dose altered the plasma clotting factors and induced a fibrinoformation alteration which occurred shortly before death. These disturbances, which were not found after gamma irradiation, could explain the importance of the haemorrhagic syndrome. Treatment by P.P.S.B. (factors II, VII, X and IX) counteracted the alterations of the plasma clotting factors, but had no influence on the lethality nor on the fibrinoformation alteration which seems to be an important cause of death [fr

  6. Chronic subdural hematoma with sedimentation level on CT: correlation with clinical and operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Hee; Lee, Hyeon Kyeong; Lee, Won Jae [College of Medicine, Dongguk University, Kyungju (Korea, Republic of)] (and others)

    1994-03-15

    The purpose of this study is to correlate CT findings of the patients with chronic subdural hematoma(SDH) showing a sedimentation level with their clinical and operative findings. We selected 9 patients who showed a sedimentation level within the hematoma after reviewing the CT findings of 55 patients with SDH. We also analyzed their age, initial symptoms, cause of head injury, latent period, the level of consciousness on admission, CT findings, and operative findings. All of the 9 patients were aged persons(over 52 years). They had a history of acute exacerbation of neurologic symptoms. Five of them had an apparent history of head trauma more than one month before the exacerbation. The CT scans showed unilateral, crescent-shaped subdural fluid collection with a sedimentation level except a case of bilateral SDH and 2 cases of planoconvex-shaped SDH. The interface of the sedimentation level was sharp in 3 cases and indistinct in 6 cases. None had bleeding tendency and the hemoglobin level was slightly decreased in 2 patients. All patients revealed membrane of the hematoma during operation. The upper portion of the sedimentation was liquefied blood and the lower portion was fresh blood clots. We could observe fresh RBC's in the hematoma microscopically. A sedimentation level in chronic SDH was operatively proved to represent rebleeding, and was clinically manifested as an acute exacerbation of symptoms.

  7. Staphylococcus chromogenes, a Coagulase-Negative Staphylococcus Species That Can Clot Plasma.

    Science.gov (United States)

    Dos Santos, Danielle Cabral; Lange, Carla Christine; Avellar-Costa, Pedro; Dos Santos, Katia Regina Netto; Brito, Maria Aparecida Vasconcelos Paiva; Giambiagi-deMarval, Marcia

    2016-05-01

    Staphylococcus chromogenes is one of the main coagulase-negative staphylococci isolated from mastitis of dairy cows. We describe S. chromogenes isolates that can clot plasma. Since the main pathogen causing mastitis is coagulase-positive Staphylococcus aureus, the coagulase-positive phenotype of S. chromogenes described here can easily lead to misidentification. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. Incorporation of albumin fusion proteins into fibrin clots in vitro and in vivo: comparison of different fusion motifs recognized by factor XIIIa

    Directory of Open Access Journals (Sweden)

    Sheffield William P

    2011-12-01

    Full Text Available Abstract Background The transglutaminase activated factor XIII (FXIIIa acts to strengthen pathological fibrin clots and to slow their dissolution, in part by crosslinking active α2-antiplasmin (α2AP to fibrin. We previously reported that a yeast-derived recombinant fusion protein comprising α2AP residues 13-42 linked to human serum albumin (HSA weakened in vitro clots but failed to become specifically incorporated into in vivo clots. In this study, our aims were to improve both the stability and clot localization of the HSA fusion protein by replacing α2AP residues 13-42 with shorter sequences recognized more effectively by FXIIIa. Results Expression plasmids were prepared encoding recombinant HSA with the following N-terminal 23 residue extensions: H6NQEQVSPLTLLAG4Y (designated XL1; H6DQMMLPWAVTLG4Y (XL2; H6WQHKIDLPYNGAG4Y (XL3; and their 17 residue non-His-tagged equivalents (XL4, XL5, and XL6. The HSA moiety of XL4- to XL6-HSA proteins was C-terminally His-tagged. All chimerae were efficiently secreted from transformed Pichia pastoris yeast except XL3-HSA, and following nickel chelate affinity purification were found to be intact by amino acid sequencing, as was an N-terminally His-tagged version of α2AP(13-42-HSA. Of the proteins tested, XL5-HSA was cross-linked to biotin pentylamine (BPA most rapidly by FXIIIa, and was the most effective competitor of α2AP crosslinking not only to BPA but also to plasma fibrin clots. In the mouse ferric chloride vena cava thrombosis model, radiolabeled XL5-HSA was retained in the clot to a greater extent than recombinant HSA. In the rabbit jugular vein stasis thrombosis model, XL5-HSA was also retained in the clot, in a urea-insensitive manner indicative of crosslinking to fibrin, to a greater extent than recombinant HSA. Conclusions Fusion protein XL5-HSA (DQMMLPWAVTLG4Y-HSAH6 was found to be more active as a substrate for FXIIIa-mediated transamidation than seven other candidate fusion proteins in

  9. The effects of Aloe vera [gel] on clotting time, prothrombin time and ...

    African Journals Online (AJOL)

    Background: Published reports on the effects of Aloe vera gel on blood coagulation in experimental animals are relatively scanty. Aim: To determine the effect of Aloe vera gel on clotting time, prothrombin time and plasma fibrinogen concentration in albino Wistar rats. Methods: A total of 28 adult albino Wistar rats divided ...

  10. CT findings of acute cholecystitis and its complications.

    Science.gov (United States)

    Shakespear, Jonathan S; Shaaban, Akram M; Rezvani, Maryam

    2010-06-01

    The purpose of this article is to describe and illustrate the CT findings of acute cholecystitis and its complications. CT findings suggesting acute cholecystitis should be interpreted with caution and should probably serve as justification for further investigation with abdominal ultrasound. CT has a relatively high negative predictive value, and acute cholecystitis is unlikely in the setting of a negative CT. Complications of acute cholecystitis have a characteristic CT appearance and include necrosis, perforation, abscess formation, intraluminal hemorrhage, and wall emphysema.

  11. Comparison of Hemostasis Times With a Kaolin-Based Hemostatic Pad (QuikClot Radial) vs Mechanical Compression (TR Band) Following Transradial Access: A Pilot Prospective Study.

    Science.gov (United States)

    Roberts, Jonathan S; Niu, Jianli; Pastor-Cervantes, Juan A

    2017-10-01

    Hemostasis following transradial access (TRA) is usually achieved by mechanical compression. We investigated use of the QuikClot Radial hemostasis pad (Z-Medica) compared with the TR Band (Terumo Medical) to shorten hemostasis after TRA. Thirty patients undergoing TRA coronary angiography and/or percutaneous coronary intervention were randomized into three cohorts post TRA: 10 patients received mechanical compression with the TR Band, 10 patients received 30 min of compression with the QuikClot Radial pad, and 10 patients received 60 min of compression with the QuikClot Radial pad. Times to hemostasis and access-site complications were recorded. Radial artery patency was evaluated 1 hour after hemostasis by the reverse Barbeau's test. There were no differences in patient characteristics, mean dose of heparin (7117 ± 1054 IU), or mean activated clotting time value (210 ± 50 sec) at the end of procedure among the three groups. Successful hemostasis was achieved in 100% of patients with both the 30-min and 60-min compression groups using the QuikClot pad. Hemostasis failure occurred in 50% of patients when the TR Band was initially weaned at the protocol-driven time (40 min after sheath removal). Mean compression time for hemostasis with the TR Band was 149.4 min compared with 30.7 min and 60.9 min for the 30-min and 60-min QuikClot groups, respectively. No radial artery occlusion occurred in any subject at the end of the study. Use of the QuikClot Radial pad following TRA in this pilot trial significantly shortened hemostasis times when compared with the TR Band, with no increased complications noted.

  12. Wedge-shaped lesion in the liver seen on postoperative CT. Probable thromboembolic phenomenon in the portal venous system

    International Nuclear Information System (INIS)

    Yoshimitsu, K.; Charnsangavej, C.; Mi Park, J.; Ibukuro, K.

    1996-01-01

    Retrospective review of teaching files in our institution revealed 18 cases showing postoperative WSL in the liver. We also retrospectively reviewed CT images of the liver in 104 patients with a recent history of abdominopelvic surgery performed during a period of 12 months, as well as in 102 patients with no history of surgery during the same period to be used as control. Three additional patients with WSL were found in the postoperative group and none in the control group. Liver CT images from the 21 patients showing WSL, along with their clinical data and follow-up CT where available, were retrospectively analyzed. I.v. contrast-enhanced CT showed homogeneous higher attenuation of WSL than the surrounding liver in all cases; unenhanced CT showed low density in 5 patients, isodensity in 7 patients, and high density in 5 patients as compared with the surrounding liver. Density of unenhanced CT was significantly correlated with the presence or grade of fatty liver. In 5 cases CT demonstrated clots in the portal vein branch within the area of WSL and in 2 cases portal perfusion defects were observed on arterial portal CT, corresponding to the areas of WSL. Follow-up CT examinations were available on 15 patients: WSL became less prominent, or atrophic, or showed no change in 10, 2 and 3 patients respectively. Follow-up CT showed development of liver metastasis in only 3 cases. Only 2 of the 21 patients were clinically symptomatic; one had postoperative ileus and the other obstructive jaundice. Postoperative WSL may represent a thromboembolic phenomenon at the peripheral intrahepatic branch of the portal venous system during or after abdominopelvic surgery, resulting in a compensatory increase in the hepatic arterial flow that appears as wedge-shaped enhancement on CT. (orig./MG)

  13. Assessment of rotation thromboelastometry parameters in patients with essential thrombocythemia at diagnosis and after hydroxyurea therapy.

    Science.gov (United States)

    Treliński, Jacek; Okońska, Marta; Robak, Marta; Chojnowski, Krzysztof

    2016-03-01

    Patients with essential thrombocythemia suffer from thrombotic complications that are the main source of mortality. Due to its complex pathogenesis, no existing single laboratory method is able to identify the patients at highest risk for developing thrombosis. Twenty patients with essential thrombocythemia at diagnosis, 15 healthy volunteers and 20 patients treated with hydroxyurea were compared with regard to certain rotation thromboelastometry parameters. Clotting time (CT), clot formation time (CFT), α-angle, and maximum clot firmness (MCF) were assessed by using the INTEM, EXTEM, FIBTEM, and NATEM tests. Patients with essential thrombocythemia at diagnosis demonstrated significantly higher mean platelet count and markedly lower mean red blood count than controls. CT and CFT readings were found to be markedly lower in essential thrombocythemia patients at diagnosis than in the control group according to the EXTEM test. Patients at diagnosis had markedly lower CT values (EXTEM, FIBTEM) than patients on hydroxyurea therapy. Alpha angle values were markedly higher in essential thrombocythemia patients at diagnosis than in controls, according to the EXTEM, FIBTEM and NATEM tests. MCF readings were significantly higher in essential thrombocythemia patients at diagnosis than in controls according to EXTEM, INTEM, FIBTEM, and NATEM tests. Patients on hydroxyurea therapy had markedly lower MCF values according to EXTEM test than patients at diagnosis. Patients with essential thrombocythemia demonstrate a prothrombotic state at the time of diagnosis, which is reflected in changes by certain rotation thromboelastometry parameters. The hydroxyurea therapy induces downregulation of the prothrombotic features seen in essential thrombocythemia patients at diagnosis.

  14. High-throughput proteomic characterization of plasma rich in growth factors (PRGF-Endoret)-derived fibrin clot interactome.

    Science.gov (United States)

    Anitua, Eduardo; Prado, Roberto; Azkargorta, Mikel; Rodriguez-Suárez, Eva; Iloro, Ibon; Casado-Vela, Juan; Elortza, Felix; Orive, Gorka

    2015-11-01

    Plasma rich in growth factors (PRGF®-Endoret®) is an autologous technology that contains a set of proteins specifically addressed to wound healing and tissue regeneration. The scaffold formed by using this technology is a clot mainly composed of fibrin protein, forming a three-dimensional (3D) macroscopic network. This biomaterial is easily obtained by biotechnological means from blood and can be used in a range of situations to help wound healing and tissue regeneration. Although the main constituent of this clot is the fibrin scaffold, little is known about other proteins interacting in this clot that may act as adjuvants in the healing process. The aim of this study was to characterize the proteins enclosed by PRGF-Endoret scaffold, using a double-proteomic approach that combines 1D-SDS-PAGE approach followed by LC-MS/MS, and 2-DE followed by MALDI-TOF/TOF. The results presented here provide a description of the catalogue of key proteins in close contact with the fibrin scaffold. The obtained lists of proteins were grouped into families and networks according to gene ontology. Taken together, an enrichment of both proteins and protein families specifically involved in tissue regeneration and wound healing has been found. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Does prior administration of enoxaparin influence the effects of levobupivacaine on blood clotting? Assessment using the Thrombelastograph.

    LENUS (Irish Health Repository)

    Leonard, S A

    2012-02-03

    The low molecular weight heparin, enoxaparin (by inhibition of factors Xa and IIa) and amide local anaesthetics (by altering platelet function) exert anti-clotting effects. Although these agents are often used in combination during the perioperative period, their potential interactive effect on clotting has not been defined. Blood from 10 ASA I-II patients who received enoxaparin 0.5 mg kg(-1) s.c. was studied using a Thrombelastograph (TEG) either alone or in combination with levobupivacaine (2.5 mg ml(-1) or 2.5 microg ml(-1)) or saline (50% dilution). In blood from patients who had received enoxaparin 0.5 mg kg(-1) s.c. 12 h previously, levobupivacaine 2.5 mg ml(-1) (but not 2.5 microg ml(-1)) produced significant changes in TEG clotting parameters (mean (SD) 15.7 (4.8) mm, 29.6 (25.6) mm, 34.4 (14.6) mm, 34.3 (12.2) degrees compared with control values of 6.1 (1.3) mm, 2.5 (0.5) mm, 63.5 (6.4) mm and 74.1 (2.9) degrees for r, K, MA, and alpha angle respectively).

  16. Comparative evaluation of Bacillus licheniformis 5A5 and Aloe variegata milk-clotting enzymes

    Directory of Open Access Journals (Sweden)

    S. A. Ahmed

    2012-03-01

    Full Text Available The properties of a milk clotting enzyme (MCE produced by bacteria (Bacillus licheniformis 5A5 were investigated and compared to those of rennet extracted from a plant (Aloe variegata. Production of MCE by B. licheniformis 5A5 was better in static than in shaken cultures. Maximum activity (98.3 and 160.3 U/ml of clotting was obtained at 75ºC and 80ºC with bacterial and plant rennet, respectively. In the absence of substrate, the clotting activity of Aloe MCE was found to be less sensitive to heat inactivation up to 80ºC for 75 min, retaining 63.8% of its activity, while bacterial MCE was completely inhibited. CaCl2 stimulated milk clotting activity (MCA up to 2% and 1.5% for bacterial and plant enzymes. NaCl inhibited MCA for both enzymes, even at low concentration (1%. Plant MCE was more sensitive to NaCl at 3% concentration it retained 30.2% of its activity, whereas bacterial MCE retained 64.1%. Increasing skim milk concentration caused a significant increase in MCA up to 6% for both enzymes. Mn2+ stimulated the activity of bacterial and plant enzymes to 158.6 and 177.9%, respectively. EDTA and PMSF increased the activity of plant MCE by 34.4 and 41.1%, respectively, which is higher than those for the bacterial MCE (19.1 and 20.9%. Some natural materials activated MCE, the highest activation of bacterial MCE (128.1% was obtained in the presence of Fenugreek (with acid extraction. However Lupine Giza 1 (with neutral extraction gave the highest activation of plant MCE (137.9%. All extracts from Neem plant increased MCA at range from 105.6% to 136.4%. Plant MCE exhibited much better stability when stored at room temperature (25-30ºC for 30 days, retaining 51.2% of its activity. Bacterial MCE was highly stabile when stored under freezing (-18ºC, retaining 100% of its activity after 30 days. Moreover, bacterial MCE was highly tolerant to repeated freezing and thawing without loss of activity for 8 months.

  17. Can Spatiotemporal Fluoride (18F-) Uptake be Used to Assess Bone Formation in the Tibia? A Longitudinal Study Using PET/CT.

    Science.gov (United States)

    Lundblad, Henrik; Karlsson-Thur, Charlotte; Maguire, Gerald Q; Jonsson, Cathrine; Noz, Marilyn E; Zeleznik, Michael P; Weidenhielm, Lars

    2017-05-01

    When a bone is broken for any reason, it is important for the orthopaedic surgeon to know how bone healing is progressing. There has been resurgence in the use of the fluoride ( 18 F - ) ion to evaluate various bone conditions. This has been made possible by availability of positron emission tomography (PET)/CT hybrid scanners together with cyclotrons. Absorbed on the bone surface from blood flow, 18 F - attaches to the osteoblasts in cancellous bone and acts as a pharmacokinetic agent, which reflects the local physiologic activity of bone. This is important because it shows bone formation indicating that the bone is healing or no bone formation indicating no healing. As 18 F - is extracted from blood in proportion to blood flow and bone formation, it thus enables determination of bone healing progress. The primary objective of this study was to determine whether videos showing the spatiotemporal uptake of 18 F - via PET bone scans could show problematic bone healing in patients with complex tibia conditions. A secondary objective was to determine if semiquantification of radionuclide uptake was consistent with bone healing. This study investigated measurements of tibia bone formation in patients with complex fractures, osteomyelitis, and osteotomies treated with a Taylor Spatial Frame TM (TSF) by comparing clinical healing progress with spatiotemporal fluoride ( 18 F - ) uptake and the semiquantitative standardized uptake value (SUV). This procedure included static and dynamic image acquisition. For intrapatient volumes acquired at different times, the CT and PET data were spatially registered to bring the ends of the bones that were supposed to heal into alignment. To qualitatively observe how and where bone formation was occurring, time-sequenced volumes were reconstructed and viewed as a video. To semiquantify the uptake, the mean and maximum SUVs (SUVmean, SUVmax) were calculated for the ends of the bones that were supposed to heal and for normal bone, using a

  18. Molar cusp deformation evaluated by micro-CT and enamel crack formation to compare incremental and bulk-filling techniques.

    Science.gov (United States)

    Oliveira, Laís Rani Sales; Braga, Stella Sueli Lourenço; Bicalho, Aline Arêdes; Ribeiro, Maria Tereza Hordones; Price, Richard Bengt; Soares, Carlos José

    2018-07-01

    To describe a method of measuring the molar cusp deformation using micro-computed tomography (micro-CT), the propagation of enamel cracks using transillumination, and the effects of hygroscopic expansion after incremental and bulk-filling resin composite restorations. Twenty human molars received standardized Class II mesio-occlusal-distal cavity preparations. They were restored with either a bulk-fill resin composite, X-tra fil (XTRA), or a conventional resin composite, Filtek Z100 (Z100). The resin composites were tested for post-gel shrinkage using a strain gauge method. Cusp deformation (CD) was evaluated using the images obtained using a micro-CT protocol and using a strain-gauge method. Enamel cracks were detected using transillumination. The post-gel shrinkage of Z100 was higher than XTRA (P cracks than XTRA (P = 0.012). Micro-CT was an effective method for evaluating the cusp deformation. Transillumination was effective for detecting enamel cracks. There were fewer negative effects of polymerization shrinkage in bulk-fill resin restorations using XTRA than for the conventional incremental filling technique using conventional composite resin Z100. Shrinkage and cusp deformation are directly related to the formation of enamel cracks. Cusp deformation and crack propagation may increase the risk of tooth fracture. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Plasma Clot Lysis Time and Its Association with Cardiovascular Risk Factors in Black Africans

    NARCIS (Netherlands)

    Z. de Lange (Zelda); M. Pieters (Marlien); J.C. Jerling (Johann); A. Kruger (Annamarie); D.C. Rijken (Dingeman)

    2012-01-01

    textabstractStudies in populations of European descent show longer plasma clot lysis times (CLT) in patients with cardiovascular disease (CVD) than in controls. No data are available on the association between CVD risk factors and fibrinolytic potential in black Africans, a group undergoing rapid

  20. Proteases from Latex of Euphorbia spp. and Its Application on Milk Clot Formation

    Directory of Open Access Journals (Sweden)

    Fidia Fibriana

    2015-09-01

    Full Text Available Crude proteases were extracted from Euphorbiaceae family, i.e. E. milii var imperata, E. trigona, and E. maculata. Among those three crude proteases, the activity of protease from E. trigona was the highest (812.50 U/ml, whereas E. milii and E. maculata crude proteases activity were 298.60 U/ml and 95.80 U/ml, respectively. E. maculata protein concentration was the highest among those three crude enzymes (1.206 mg/ml. The optimum pH and temperature of the enzymes were pH 7.0, pH 6.0, pH 6.5 and 60 °C, 50 °C, and 50 °C, respectively. Crude protease from E. milii var imperata, E. trigona, and E. maculata retained proteolytic activity over a wide range of pH (5.0–9.0 and temperature (up to 65 °C with casein as substrate. All crude proteases showed milk clotting activity ranged from 0.58 U/ml to 1.01 U/ml. Thus, these crude proteases are potential to be applied in dairy industries. However, further study on enzyme purification and characterization are necessary to obtain high purity of proteases before its application.Protease kasar berhasil diekstrak dari tanaman family Euphorbiaceae, yaitu E. milii var imperata, E. trigona, dan E. maculata. Diantara ketiga protease tersebut, aktivitas protease tertinggi diperoleh dari E. trigona (812,50 U/ml, sedangkan aktivitas protease dari E. milii dan E. maculata adalah 298,60 U/ml dan 95,80 U/ml, berturut-turut. Konsentrasi total protein tertinggi terdapat pada protease kasar E. maculata (1,206 mg/ml. pH dan suhu optimum ketiga enzim tersebut adalah pH 7.0, pH 6.0, pH 6.5 dan suhu 60 °C, 50 °C, and 50 °C, berturut-turut. Protease kasar dari E. milii var imperata, E. trigona, dan E. maculata menunjukkan aktivitas proteolitik pada rentang pH 5.0–9.0 dan rentang suhu sampai 65 °C menggunakan kasein sebagai substrat. Semua protease kasar menunjukkan aktivitas penggumpalan susu dengan rentang dari 0,58 U/ml sampai 1,01 U/ml. Berdasarkan hasil yang diperoleh, protease kasar dari ketiga jenis tanaman ini

  1. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy.

    Science.gov (United States)

    Krebs, C R; Li, Ling; Wolberg, Alisa S; Oldenburg, Amy L

    2015-07-01

    Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (diagnostics and therapeutic monitoring.

  2. Building and validation of a prognostic model for predicting extracorporeal circuit clotting in patients with continuous renal replacement therapy.

    Science.gov (United States)

    Fu, Xia; Liang, Xinling; Song, Li; Huang, Huigen; Wang, Jing; Chen, Yuanhan; Zhang, Li; Quan, Zilin; Shi, Wei

    2014-04-01

    To develop a predictive model for circuit clotting in patients with continuous renal replacement therapy (CRRT). A total of 425 cases were selected. 302 cases were used to develop a predictive model of extracorporeal circuit life span during CRRT without citrate anticoagulation in 24 h, and 123 cases were used to validate the model. The prediction formula was developed using multivariate Cox proportional-hazards regression analysis, from which a risk score was assigned. The mean survival time of the circuit was 15.0 ± 1.3 h, and the rate of circuit clotting was 66.6 % during 24 h of CRRT. Five significant variables were assigned a predicting score according to the regression coefficient: insufficient blood flow, no anticoagulation, hematocrit ≥0.37, lactic acid of arterial blood gas analysis ≤3 mmol/L and APTT R (2) = 0.232; P = 0.301). A risk score that includes the five above-mentioned variables can be used to predict the likelihood of extracorporeal circuit clotting in patients undergoing CRRT.

  3. Case of pancreatolithiasis. CT observation of calculus formation

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira (Fujita-Gakuen Univ., School of Medicine, Aichi (Japan))

    1982-11-01

    During 3-year follow-up of a case of pancreatolithiasis localized in the pancreatic head, CT showed sudden new appearance of calculi over an extensive area of the body and tail of the pancreas after acute exacerbation of chronic pancreatitis. This case and the etiology and mechanism of pancreatolithiasis were discussed on the basis of literature.

  4. Investigation of the thrombin-generating capacity, evaluated by thrombogram, and clot formation evaluated by thrombelastography of platelets stored in the blood bank for up to 7 days.

    Science.gov (United States)

    Johansson, P I; Svendsen, M S; Salado, J; Bochsen, L; Kristensen, A T

    2008-02-01

    Transfusion based on the Thrombelastograph (TEG) results reduces transfusion requirements in cardiac surgery and in liver transplantation. Taking the pivotal role of thrombin generation in the coagulation process into consideration, the clinical utility of the TEG may, in part, depend on its reflection of the dynamics of thrombin generation. The kinetics of thrombin generation of platelets stored for 2 and 7 days, respectively, was assessed by calibrated automated thrombogram (CAT) and the lag time (min), time to peak (ttPeak; min), peak (nm thrombin) and endogenous thrombin potential (ETP; nm thrombin*min) were registered. Clot formation was evaluated by TEG and the R time (min), maxial amplitude (MA; mm), time to maximum thrombus generation (TMG; min) and maximum thrombus generation (MTG; dynes cm(-2) s(-1)) and total thrombus generation (TTG; dyne cm(-2)) were registered. Platelets become more procoagulant, evaluated both by TEG and CAT during storage. The reduction in CAT lag time and the ttPeak correlated with a decrease in the TEG R time and TMG (P < 0.0001) as did the CAT peak thrombin generation and the TEG MTG (P = 0.0035). No correlation between ETP and TTG was found (P = 0.65). The kinetics of thrombin generation, as evaluated by CAT, correlates with the thrombus generation, as evaluated by thrombelastography and this may in part explain the clinical utility of the TEG in identifying clinically relevant coagulopathies, secondary to impaired thrombin generation.

  5. Development and comparison of a minimally-invasive model of autologous clot pulmonary embolism in Sprague-Dawley and Copenhagen rats

    Directory of Open Access Journals (Sweden)

    Sanapareddy Nina

    2010-02-01

    Full Text Available Abstract Background Experimental models of pulmonary embolism (PE that produce pulmonary hypertension (PH employ many different methods of inducing acute pulmonary occlusion. Many of these models induce PE with intravenous injection of exogenous impervious objects that may not completely reproduce the physiological properties of autologous thromboembolism. Current literature lacks a simple, well-described rat model of autlogous PE. Objective: Test if moderate-severity autologous PE in Sprague-Dawley (SD and Copenhagen (Cop rats can produce persistent PH. Methods blood was withdrawn from the jugular vein, treated with thrombin-Ca++ and re-injected following pretreatment with tranexamic acid. Hemodynamic values, clot weights and biochemical measurements were performed at 1 and 5 days. Results Infusion of clot significantly increased the right ventricular peak systolic pressure to 45-55 mm Hg, followed by normalization within 24 hours in SD rats, and within 5 days in COP rats. Clot lysis was 95% (24 hours and 97% (5 days in SD rats and was significantly lower in COP rats (70%, 24 hours; 87% 5 days. Plasma D-dimer was elevated in surgical sham animals and was further increased 8 hours after pulmonary embolism. Neither strain showed a significant increase in bronchoalveolar chemotactic activity, myeloperoxidase activity, leukocyte infiltration, or chemokine accumulation, indicating that there was no significant pulmonary inflammation. Conclusions Both SD and COP rats exhibited near complete fibrinolysis of autologous clot PE within 5 days. Neither strain developed persistent PH. Experimental models of PE designed to induce sustained PH and a robust inflammatory response appear to require significant, persistent pulmonary vascular occlusion.

  6. Synthesis, purification, and characterization of an Arg152 → Glu site-directed mutant of recombinant human blood clotting factor VII

    International Nuclear Information System (INIS)

    Wildgoose, P.; Kisiel, W.; Berkner, K.L.

    1990-01-01

    Coagulation factor VII circulates in blood as a single-chain zymogen of a serine protease and is converted to its activated two-chain form, factor VIIa, by cleavage of an internal peptide bond located at Arg 152 -Ile 153 . Previous studies using serine protease active-site inhibitors suggest that zymogen factor VII may possess sufficient proteolytic activity to initiate the extrinsic pathway of blood coagulation. In order to assess the putative intrinsic proteolytic activity of single-chain factor VII, the authors have constructed a site-specific mutant of recombinant human factor VII in which arginine-152 has been replaced with a glutamic acid residue. Mutant factor VII was purified in a single step from culture supernatants of baby hamster kidney cells transfected with a plasmid containing the sequence for Arg 152 → Glu factor VII using a calcium-dependent, murine anti-factor VII monoclonal antibody column. The clotting activity of mutant factor VII was completely inhibited following incubation with dansyl-Glu-Gly-Arg chloromethyl ketone, suggesting that the apparent clotting activity of mutant factor VII was due to a contaminating serine protease. Immunoblots of mutant factor VII with human factor IXa revealed no cleavage, whereas incubation of mutant factor VII with human factor Xa resulted in cleavage of mutant factor VII and the formation of a lower molecular weight degradation product migrating at M r ∼40 000. The results are consistent with the proposal that zymogen factor VII possesses no intrinsic proteolytic activity toward factor X or factor IX

  7. A novel clot lysis assay for recombinant plasminogen activator.

    Science.gov (United States)

    Jamialahmadi, Oveis; Fazeli, Ahmad; Hashemi-Najafabadi, Sameereh; Fazeli, Mohammad Reza

    2015-03-01

    Recombinant plasminogen activator (r-PA, reteplase) is an engineered variant of alteplase. When expressed in E. coli, it appears as inclusion bodies that require refolding to recover its biological activity. An important step following refolding is to determine the activity of refolded protein. Current methods for enzymatic activity of thrombolytic drugs are costly and complex. Here a straightforward and low-cost clot lysis assay was developed. It quantitatively measures the activity of the commercial reteplase and is also capable of screening refolding conditions. As evidence for adequate accuracy and sensitivity of the current assay, r-PA activity measurements are shown to be comparable to those obtained from chromogenic substrate assay.

  8. Clinical and CT scan pictures of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Singounas, E.G.; Krassanakis, K.; Karvounis, P.C. (Evangelismos Hospital, Athens (Greece))

    1982-01-01

    The clinical presentations and CT scan pictures of four patients harbouring big cysticercus cysts are described. The value of CT scanning in detecting these cysts is emphasized, and also the fact that these cysts can behave as space-occyping lesions, which must be differentiated from other cystic formations.

  9. CT of osteomyelitis of the spine

    International Nuclear Information System (INIS)

    Golimbu, C.; Firooznia, H.; Rafii, M.

    1984-01-01

    Computed tomography (CT) scans were performed in 17 adults with osteomyelitis of the spine. The dominant features were paravertebral soft-tissue swelling, abscess formation, and bone erosion. In two patients there were no findings indicative of osteomyelitis on conventional radiographs, but CT revealed paravertebral abscesses and bone lysis, helping to establish the diagnosis of osteomyelitis, chiefly because of its ability to detect early erosion of spongy vertabral bone, disk involvement, paravertebral soft-tissue swelling or abscess, and extension of the pathology into the spinal canal. Furthermore, CT facilitated closed-needle biopsy, helping to establish the pathologic diagnosis

  10. MATHEMATICAL MODELING OF SELF-EXCITED VIBRATION OF PIPES CONTAINING MOBILE BOILING FLUID CLOTS

    Directory of Open Access Journals (Sweden)

    Yevgeniy Tolbatov

    2015-06-01

    Full Text Available Numerical modeling dynamic behavior of a pipe containing inner nonhomogeneous flows of a boiling fluid has been carried out. The system vibrations at different values of the parameters of the flow nonhomogeneity and its velocity are observed. The possibility of forming stable and unstable flows depending on the character ofnonhomogeneity and the velocity of fluid clots has been found.

  11. Intraventricular hemorrhage in the newborn and very young infant

    International Nuclear Information System (INIS)

    Takagi, Takuji; Togari, Hajime; Shimizu, Kuniki

    1980-01-01

    CT has been established as a rapid, safe and non-invasive technique for the diagnosis of neonatal intraventricular hemorrhage (IVH). It demonstrates the precise extent of IVH after birth. Eight infants with IVH (5 boys and 3 girls) were studied with CT using an EMI (1010) scanner. Five of the eight infants survived. Three infants (cases 1, 2 and 6) developed severe hydrocephalus. Shunting procedure were performed on these 3 cases, and they survived. The remainder (cases 3, 4, 7 and 8), examined within 5 days after the onset of symptoms, showed IVH. Cases 3, 7 and 8 died. Case 3 had an extensive hematoma in the right lateral ventricle, while case 7 and 8 had a hematoma forming a cast in the whole ventricular system. Case 5 and 6 had clots in the trigonum of both lateral ventricles. In cases 4, 5 and 6, spinal taps were performed frequently to reduce intracranial pressure, and CT was repeated one time a week. Case 4 showed no hydrocephalus. In case 5, the clots became smaller gradually and disappeared on the 25th day after birth. The lateral ventricles distended gradually. However, the distension was spontaneously arrested in this case. Case 6 showed progressive hydrocephalus despite repeated spinal taps, so V-P shunt was performed. But the shunt system was removed on the 14th postoperative day because of malfunction in the system. Thereafter he showed no hydrocephalus. Types of IVH are classified by CT findings into 4 groups: 1) showing hydrocephalus, 2) clotting observed in one ventricle, 3) clotting observed in 2 ventricles, 4) clotting observed throughout the ventricular system. Thus, CT provides useful diagnostic information about the presence, site and distension of the IVH. Its findings enable the physician to make an appropriate prognostic judgement. (author)

  12. Oxygen-implanted induced formation of oxide layer enhances blood compatibility on titanium for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Wei-Chiang [School of Oral Hygiene, Taipei Medical University, Taipei 110, Taiwan (China); Department of Dentistry, Taipei Medical University Hospital, Taipei 110, Taiwan (China); Chang, Fang-Mo [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Yang, Tzu-Sen [Master Program in Graduate Institute of Nanomedicine and Medical Engineering, Taipei Medical University, Taipei 110, Taiwan (China); Ou, Keng-Liang [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Research Center for Biomedical Implants and Microsurgery Devices, Taipei Medical University, Taipei 110, Taiwan (China); Department of Dentistry, Taipei Medical University-Shuang-Ho Hospital, Taipei 235, Taiwan (China); Lin, Che-Tong [School of Dentistry, Taipei Medical University, Taipei 110, Taiwan (China); Peng, Pei-Wen, E-mail: apon@tmu.edu.tw [School of Dental Technology, Taipei Medical University, Taipei 110, Taiwan (China)

    2016-11-01

    Titanium dioxide (TiO{sub 2}) layers were prepared on a Ti substrate by using oxygen plasma immersion ion implantation (oxygen PIII). The surface chemical states, structure, and morphology of the layers were studied using X-ray photoelectron spectroscopy, X-ray diffraction, Raman microscopy, atomic force microscopy and scanning electron microscope. The mechanical properties, such as the Young's modulus and hardness, of the layers were investigated using nanoindentation testing. The Ti{sup 4+} chemical state was determined to be present on oxygen-PIII-treated surfaces, which consisted of nanocrystalline TiO{sub 2} with a rutile structure. Compared with Ti substrates, the oxygen-PIII-treated surfaces exhibited decreased Young's moduli and hardness. Parameters indicating the blood compatibility of the oxygen-PIII-treated surfaces, including the clotting time and platelet adhesion and activation, were studied in vitro. Clotting time assays indicated that the clotting time of oxygen-PIII-treated surfaces was longer than that of the Ti substrate, which was associated with decreased fibrinogen adsorption. In conclusion, the surface characteristics and the blood compatibility of Ti implants can be modified and improved using oxygen PIII. - Highlights: • The Ti{sup 4+} chemical state was determined to be present on oxygen-PIII-treated surfaces. • The nanocrystalline TiO{sub 2} with a rutile structure was formed on titanium surfaces. • A nanoporous TiO{sub 2} layer in the rutile phase prepared using oxygen PIII treatment can be used to prolong blood clot formation.

  13. ANGUSTIFOLIA, a Plant Homolog of CtBP/BARS Localizes to Stress Granules and Regulates Their Formation

    Directory of Open Access Journals (Sweden)

    Hemal Bhasin

    2017-06-01

    Full Text Available The ANGUSTIFOLIA (AN gene in Arabidopsis is important for a plethora of morphological phenotypes. Recently, AN was also reported to be involved in responses to biotic and abiotic stresses. It encodes a homolog of the animal C-terminal binding proteins (CtBPs. In contrast to animal CtBPs, AN does not appear to function as a transcriptional co-repressor and instead functions outside nucleus where it might be involved in Golgi-associated membrane trafficking. In this study, we report a novel and unexplored role of AN as a component of stress granules (SGs. Interaction studies identified several RNA binding proteins that are associated with AN. AN co-localizes with several messenger ribonucleoprotein granule markers to SGs in a stress dependent manner. an mutants exhibit an altered SG formation. We provide evidence that the NAD(H binding domain of AN is relevant in this context as proteins carrying mutations in this domain localize to a much higher degree to SGs and strongly reduce AN dimerization and its interaction with one interactor but not the others. Finally, we show that AN is a negative regulator of salt and osmotic stress responses in Arabidopsis suggesting a functional relevance in SGs.

  14. CT and SPECT in bilateral hypertensive intracerebral hemorrhages of simultaneous onset

    International Nuclear Information System (INIS)

    Kikuchi, Kenji; Kojima, Hisashi; Kowada, Masayoshi; Ogayama, Hiroyuki; Watanabe, Kazuo.

    1988-01-01

    A 59-year-old woman was admitted to the hospital on November 6, 1983, after she suddenly lost consciousness. She was semicomatous, and the level of consciousness was evaluated as 100 according to the Japan Coma Scale. There were left hemiparesis and conjugate deviation to the right. CT scans obtained one hour after onset demonstrated bilateral intracerebral hemorrhages involving the right basal ganglia and the left posterior temporal region. Carotid angiograms failed to demonstrate the presence of either cerebral aneurysms or arteriovenous malformations which might be responsible for the intracerebral hemorrhages. A right fronto-temporal craniotomy was performed, and about 50 ml of intracerebral blood clots were evacuated by the transcortical approach. The patient was discharged with left hemiparesis, disorientation, and pseudobulbar palsy. A 57-year-old man was transferred to the hospital on February 22, 1986, with an episode of cerebral stroke. On admission he was free of symptoms except for mild hemiparesis on the right side. CT scan was performed nine days after onset, revealing bilateral intracerebral hemorrhages involving the right putamen and the left thalamus. Bilateral carotid angiograms showed an avascular mass lesion medial to the left insula, displacing both the left lenticulostriate arteries and the insular segment of the left middle cerebral artery laterally. No abnormal vascular lesions, such as cerebral aneurysms and arteriovenous malformations, were demonstrated. SPECT was performed using the continuous inhalation of Xe-133, and a prolonged decrease in the cerebral blood flow was demonstrated in the vicinity of the bilateral intracerebral hematomas, in contrast to the gradual alleviations shown on CT images. (J.P.N.)

  15. Defective tubulin organization and proplatelet formation in murine megakaryocytes lacking Rac1 and Cdc42

    DEFF Research Database (Denmark)

    Pleines, Irina; Dütting, Sebastian; Cherpokova, Deya

    2013-01-01

    Blood platelets are anuclear cell fragments that are essential for blood clotting. Platelets are produced by bone marrow megakaryocytes (MKs), which extend protrusions, or so-called proplatelets, into bone marrow sinusoids. Proplatelet formation requires a profound reorganization of the MK actin...... normally in vivo but displayed highly abnormal morphology and uncontrolled fragmentation. Consistently, a lack of Rac1/Cdc42 virtually abrogated proplatelet formation in vitro. Strikingly, this phenotype was associated with severely defective tubulin organization, whereas actin assembly and structure were...

  16. CT features of peritonitis associated with continuous ambulatory peritoneal dialysis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Byun, Jae Young; Lee, Sang Hoon; Kwon, Tae Ahn; Kim, Yeon Kil; Kim, Young Ok; Song, Kyung Sup [The Catholic Univ. of Korea College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To evaluate the CT findings of peritonitis associated with continuous ambulatory peritoneal dialysis(CAPD). We retrospectively analyzed CT scans of 14 symptomatic patients with peritonitis after CAPD. Diffuse abdominal pain was present in 11, fever in two, and abdominal mass with vomiting in one. The mean duration of CAPD ranged from 10 months to 5 years(mean : 3.9 years). On abdominal CT, we evaluated the presence and location of ascites, bowel wall thickening, cocoon formation, the pattern of enhancement of peritoneal thickening, the presence of calcifications in the peritoneum, and mesenteric and omental change. On enhanced CT, multiloculated ascites was observed in all cases(n=14) ; it was located mainly in the pelvic cavity with small multi-loculated fluid collections in the peritoneal cavity(n=13), including the lesser sac(n=3). In one patient, ascites was located in the space between the greater omentum and anterior peritoneal surface. CT showed ileus in 12 cases, small bowel wall thickening in 11, and cocoon formation in five. Uneven but smooth thickening of the peritoneum, with contrast enhancement, was seen in eight cases, and in five of these, peritoneal thickening was more prominent in the anterior peritoneum. Other findings included reticular opacity in two cases, hematoma of the rectus muscle in one, and umbilical hernia in one. Multiloculated fluid collection, ileus, small bowel wall thickening, uneven but smooth peritoneal thickening, and cocoon formation appear to be CT features of CAPD peritonitis.

  17. CT features of peritonitis associated with continuous ambulatory peritoneal dialysis

    International Nuclear Information System (INIS)

    Yun, Ji Young; Byun, Jae Young; Lee, Sang Hoon; Kwon, Tae Ahn; Kim, Yeon Kil; Kim, Young Ok; Song, Kyung Sup

    1999-01-01

    To evaluate the CT findings of peritonitis associated with continuous ambulatory peritoneal dialysis(CAPD). We retrospectively analyzed CT scans of 14 symptomatic patients with peritonitis after CAPD. Diffuse abdominal pain was present in 11, fever in two, and abdominal mass with vomiting in one. The mean duration of CAPD ranged from 10 months to 5 years(mean : 3.9 years). On abdominal CT, we evaluated the presence and location of ascites, bowel wall thickening, cocoon formation, the pattern of enhancement of peritoneal thickening, the presence of calcifications in the peritoneum, and mesenteric and omental change. On enhanced CT, multiloculated ascites was observed in all cases(n=14) ; it was located mainly in the pelvic cavity with small multi-loculated fluid collections in the peritoneal cavity(n=13), including the lesser sac(n=3). In one patient, ascites was located in the space between the greater omentum and anterior peritoneal surface. CT showed ileus in 12 cases, small bowel wall thickening in 11, and cocoon formation in five. Uneven but smooth thickening of the peritoneum, with contrast enhancement, was seen in eight cases, and in five of these, peritoneal thickening was more prominent in the anterior peritoneum. Other findings included reticular opacity in two cases, hematoma of the rectus muscle in one, and umbilical hernia in one. Multiloculated fluid collection, ileus, small bowel wall thickening, uneven but smooth peritoneal thickening, and cocoon formation appear to be CT features of CAPD peritonitis

  18. Synthesis, purification, and characterization of an Arg sub 152 yields Glu site-directed mutant of recombinant human blood clotting factor VII

    Energy Technology Data Exchange (ETDEWEB)

    Wildgoose, P.; Kisiel, W. (Univ. of New Mexico, Albuquerque (USA)); Berkner, K.L. (ZymoGenetics, Inc., Seattle, WA (USA))

    1990-04-03

    Coagulation factor VII circulates in blood as a single-chain zymogen of a serine protease and is converted to its activated two-chain form, factor VIIa, by cleavage of an internal peptide bond located at Arg{sub 152}-Ile{sub 153}. Previous studies using serine protease active-site inhibitors suggest that zymogen factor VII may possess sufficient proteolytic activity to initiate the extrinsic pathway of blood coagulation. In order to assess the putative intrinsic proteolytic activity of single-chain factor VII, the authors have constructed a site-specific mutant of recombinant human factor VII in which arginine-152 has been replaced with a glutamic acid residue. Mutant factor VII was purified in a single step from culture supernatants of baby hamster kidney cells transfected with a plasmid containing the sequence for Arg{sub 152} {yields} Glu factor VII using a calcium-dependent, murine anti-factor VII monoclonal antibody column. The clotting activity of mutant factor VII was completely inhibited following incubation with dansyl-Glu-Gly-Arg chloromethyl ketone, suggesting that the apparent clotting activity of mutant factor VII was due to a contaminating serine protease. Immunoblots of mutant factor VII with human factor IXa revealed no cleavage, whereas incubation of mutant factor VII with human factor Xa resulted in cleavage of mutant factor VII and the formation of a lower molecular weight degradation product migrating at M{sup r}{approx}40 000. The results are consistent with the proposal that zymogen factor VII possesses no intrinsic proteolytic activity toward factor X or factor IX.

  19. Laryngotracheobronchial papillomatosis: chest CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, Helena Ribeiro; Zanetti, Glaucia; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Ranke, Felipe Mussi von [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Escuissato, Dante Luiz [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Clinica Medica; Araujo Neto, Cesar Augusto [Universidade Federal da Bahia (UFBA), Salvador (Brazil). Dept. de Medicina e Apoio Diagnostico; Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Diagnostico por Imagem; Irion, Klaus Loureiro [Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool (United Kingdom); Souza, Carolina Althoff [Dept. of Diagnostic Imaging, The Ottawa Hospital, University of Ottawa, Ontario (Canada)

    2017-07-15

    To evaluate the findings on chest CTs in 16 patients (8 men and 8 women) with laryngotracheobronchial papillomatosis. Methods: This was a retrospective study involving patients ranging from 2 to 72 years of age. The evaluation of the CT scans was independently performed by two observers, and discordant results were resolved by consensus. The inclusion criteria were presence of abnormalities on the CT scans, and the diagnosis was confirmed by anatomopathological examination of the papillomatous lesions. Results: The most common symptoms were hoarseness, cough, dyspnea, and recurrent respiratory infections. The major CT findings were nodular formations in the trachea, solid or cavitated nodules in the lung parenchyma, air trapping, masses, and consolidation. Nodular formations in the trachea were observed in 14 patients (87.5%). Only 2 patients had lesions in lung parenchyma without tracheal involvement. Only 1 patient had no pulmonary dissemination of the disease, showing airway involvement only. Solid and cavitated lung nodules were observed in 14 patients (87.5%) and 13 (81.2%), respectively. Masses were observed in 6 patients (37.5%); air trapping, in 3 (18.7%); consolidation in 3 (18.7%); and pleural effusion, in 1 (6.3%). Pulmonary involvement was bilateral in all cases. Conclusions: The most common tomography findings were nodular formations in the trachea, as well as solid or cavitated nodules and masses in the lung parenchyma. Malignant transformation of the lesions was observed in 5 cases. (author)

  20. Study on sup(99m)Tc-colloid accumulation of in vitro clots and thrombi in rats

    Energy Technology Data Exchange (ETDEWEB)

    Ohguchi, Manabu [Kanazawa Univ. (Japan). School of Medicine

    1983-02-01

    The accumulation of different sup(99m)Tc-colloids in vitro clot, venous thrombi and intravascular fibrin deposits in rats was studied. Blood clot was produced by incubating fresh blood at room temperature for three hours. The mean value of % uptake of sup(99m)Tc-Sn colloid in clot was 96.2 % and higher than that of any other sup(99m)Tc-colloids. Venous thrombi in rats were made by clamping the left femoral vein segments for 5 minutes. With sup(99m)Tc-Sn colloid, the mean value of the ratio of the radioactivity in the clamped vein segment to the control segment (L/R ratio) was 54.5. L/R ratios of others were 24.2 with sup(99m)Tc-phytate, 12.1 with sup(99m)Tc-sulfur colloid, 3.9 with sup(99m)Tc-rhenium colloid, 2.4 with sup(99m)Tc-millimicrosphere albumin. L/R ratios were higher for the fresh thrombi, significant uptake was also observed up to seven days. Intravascular fibrin deposits were induced by i.p. injection of endotoxin into rats. Three hours after injection of endotoxin, sup(99m)Tc-colloids were i.v. injected. Significant lung uptake was observed in sup(99m)Tc-colloids except in sup(99m)Tc-rhenium colloid. And the most remarkable change of lung uptake was observed in sup(99m)Tc-Sn colloid. Significant kidney uptake was observed in sup(99m)Tc-Sn colloid and sup(99m)Tc-sulfur colloid. And the most remarkable change of kidney uptake was also observed in sup(99m)Tc-Sn colloid. When heparin was injected i.v. at the same time as endotoxin injection, lung uptake of sup(99m)Tc-Sn colloid was significantly decreased. However, the heparin effect on kidney uptake of sup(99m)Tc-Sn colloid was more significant than on lung uptake. The results in this study indicated that sup(99m)Tc-Sn colloid showed the greatest affinity to in vitro clots, venous thrombi and intravascular fibrin deposits.

  1. Monitoring of unfractionated heparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent (PiCT®).

    Science.gov (United States)

    Schaden, E; Jilch, S; Hacker, S; Schober, A; Kozek-Langenecker, S

    2012-12-24

    To achieve sufficient and safe anticoagulation with unfractionated heparin (UFH) a close and reliable drug monitoring is necessary. In general, the activated partial thromboplastin time (APTT) is used for this purpose. In acute phase response, however, the APTT test procedure might be unreliable e.g. with false low results in the presence of elevated factor VIII. In this so called heparin resistance, measurement of anti-Xa activity is recommended over APTT to avoid potentially harmful dose escalation. A combination of anti-Xa measurement and global hemostatic testing with ROTEM® employing the anti-Xa sensitive PiCT® reagent showed high correlation with enoxaparin levels. This test modification could also be suitable for monitoring UFH. Aim of the study was to evaluate the correlation between PiCT®-ROTEM® and levels of UFH. In this in-vitro study blood samples from healthy volunteers were spiked with UFH and subjected to different ROTEM® tests. There was a linear correlation between UFH level and clotting time (CT) in the PiCT®-ROTEM® test with an excellent correlation coefficient of 0.92. Additional endpoints showed similar results (PiCT®-ROTEM® MaxVel r = -0.85 and PiCT®-ROTEM® t_MaxVel r = 0.88). As a point-of-care applicable tool ROTEM® is immediately at hand. If further clinical studies confirm sensitivity in heparin resistance, PiCT®-ROTEM® could permit rapid UFH dose adjustments especially required in critical illness with acute phase response. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Indium-111 platelet scintigraphy and two-dimensional echocardiography for detection of left ventricular thrombus: influence of clot size and age

    International Nuclear Information System (INIS)

    Seabold, J.E.; Schroeder, E.C.; Conrad, G.R.

    1987-01-01

    Two-dimensional echocardiography and indium-111 platelet scintigraphy were performed on 50 dogs to determine the influence of clot age and size on the detection of experimentally induced left ventricular mural thrombus. Thrombus was induced by apical infarction and injection of a sclerosing agent and thrombin. The animals were classified into four groups according to the time of indium-111 platelet injection after thrombus induction: Group I (17 dogs, 1/2 hour after induction; 3 dogs, before induction), Group II (12 dogs, 24 hours after induction) and Group III (12 dogs, 1 week after induction). In Group IV (six control dogs) apical infarction was produced, but thrombin was not injected; indium-111 platelets were injected 1/2 to 1 hour after infarction. The dogs were studied by indium-111 platelet scintigraphy and by two-dimensional echocardiography 1/2 to 5 hours (Group I) and 1 to 5 and up to 72 hours (Groups II to IV) after platelet administration and before death was induced. Two-dimensional echocardiography showed the best overall sensitivity for detection of acute thrombus (97%; 29 of 30). The sensitivity of indium-111 platelet scintigraphy was 86% (18 of 21) for clots greater than or equal to 0.08 ml in size, and 67% (20 of 30) for detection of all clots. Thrombus did not form in 14 dogs of Groups I to III and in 6 of 6 control dogs. The specificity of scintigraphy was 100% (20 of 20) compared with 80% (16 of 20) for echocardiography. Echocardiography was more sensitive than scintigraphy for detecting very small clots in this experimental model

  3. Biological variation in tPA-induced plasma clot lysis time.

    Science.gov (United States)

    Talens, Simone; Malfliet, Joyce J M C; Rudež, Goran; Spronk, Henri M H; Janssen, Nicole A H; Meijer, Piet; Kluft, Cornelis; de Maat, Moniek P M; Rijken, Dingeman C

    2012-10-01

    Hypofibrinolysis is a risk factor for venous and arterial thrombosis, and can be assessed by using a turbidimetric tPA-induced clot lysis time (CLT) assay. Biological variation in clot lysis time may affect the interpretation and usefulness of CLT as a risk factor for thrombosis. Sufficient information about assay variation and biological variation in CLT is not yet available. Thus, this study aimed to determine the analytical, within-subject and between-subject variation in CLT. We collected blood samples from 40 healthy individuals throughout a period of one year (average 11.8 visits) and determined the CLT of each plasma sample in duplicate. The mean (± SD) CLT was 83.8 (± 11.1) minutes. The coefficients of variation for total variation, analytical variation, within-subject variation and between-subject variation were 13.4%, 2.6%, 8.2% and 10.2%, respectively. One measurement can estimate the CLT that does not deviate more than 20% from its true value. The contribution of analytical variation to the within-subject variation was 5.0%, the index of individuality was 0.84 and the reference change value was 23.8%. The CLT was longer in the morning compared to the afternoon and was slightly longer in older individuals (> 40 years) compared to younger (≤40 years) individuals. There was no seasonal variation in CLT and no association with air pollution. CLT correlated weakly with fibrinogen, C-reactive protein, prothrombin time and thrombin generation. This study provides insight into the biological variation of CLT, which can be used in future studies testing CLT as a potential risk factor for thrombosis.

  4. The CT findings of spinal tuberculosis

    International Nuclear Information System (INIS)

    Li Yizhao; Liu Jianming; Ke Yong; XiaoYong; Liu Rihua

    2002-01-01

    Objective: To investigate the CT diagnosis and differential diagnosis of spinal tuberculosis. Methods: CT manifestations were retrospectively analyzed in 43 cases of spinal tuberculosis. This series included 24 males and 19 females, aged 10-57 years. 15 cases were confirmed by operation and pathology; 18 cases were confirmed by biopsy and 10 cases were cured by antituberculosis therapy. Results: The CT manifestations of spinal tuberculosis were: 1) mottling, patchy, caved or faveolate bone destructions (43/43 cases); 2) elevated density of the involved vertebrae (13/43 cases); 3) destruction of intervertebral discs (32/43 cases); 4) formation of sequester (30/43 cases); 5) para-vertebral abscess, often with calcification (38/43 cases); 6) osseous vertebral canal narrowing (8/43 cases); 7) vertebrae compression (28/43 cases). Conclusion: CT scan is a valuable modality for the diagnosis and differential diagnosis of spinal tuberculosis

  5. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    Science.gov (United States)

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the

  6. N-terminal Pro-brain Natriuretic Peptide, High-sensitivity Troponin and Pulmonary Artery Clot Score as Predictors of Right Ventricular Dysfunction in Echocardiography.

    Science.gov (United States)

    Granér, Marit; Harjola, Veli-Pekka; Selander, Tuomas; Laiho, Mia K; Piilonen, Anneli; Raade, Merja; Mustonen, Pirjo

    2016-06-01

    We investigated the ability of cardiac biomarkers and total pulmonary artery (PA) clot score to predict right ventricular dysfunction (RVD) on admission and at seven-month follow-up in subjects with acute pulmonary embolism (APE). Sixty-three normotensive patients with APE were divided into two groups: patients with (n= 32, age 58±19 years) and without (n=31, age 55±16 years) echocardiographic RVD. Transthoracic echocardiography (TTE), N-terminal pro-brain natriuretic peptide (NT-proBNP), and high-sensitivity troponin T (hsTnT) were assessed upon arrival and repeated at seven months. Total PA clot score was determined on admission. The age- and sex dependent NT-proBNP on admission, on day 5, and at seven months exhibited the best sensitivity (admission 94%, day 5 100%, seven months 100%) and negative predictive value (NPV) (89%, 100%, 100%) for detecting RVD. Six patients (10%) had persistent RVD at seven months. Total PA clot score showed only low to moderate sensitivity (77%) and PPV (7%) for detection of RVD at seven months. Normal age- and sex dependent NT-proBNP on admission or measured five days later seems to be useful in exclusion of RVD at follow up. Total PA clot score shows only to be of modest benefit for predicting persistent RVD. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Pancreatic changes in cystic fibrosis: CT and sonographic appearances

    International Nuclear Information System (INIS)

    Daneman, A.; Gaskin, K.; Martin, D.J.; Cutz, E.

    1983-01-01

    The computed tomographic (CT) and sonographic appearances of the late stages of pancreatic damage in three patients with cystic fibrosis are illustrated. All three had severe exocrine pancreatic insufficiency with steatorrhea. In two patients CT revealed complete fatty replacement of the entire pancreas. In the third, increased echogenicity of the pancreas on sonography and the inhomogeneous attenuation on CT were interpreted as being the result of a combination of fibrosis, fatty replacement, calcification, and probable cyst formation

  8. The value of early CT in complicated childhood pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Tan Kendrick, A.P. [Department of Diagnostic Imaging, Kandang Kerbau Women' s and Children' s Hospital (Singapore); Ling, Ho [Department of Paediatric Medicine, Kandang Kerbau Women' s and Children' s Hospital (Singapore); Subramaniam, Ramnath; Joseph, Vijeyakaran T. [Department of Paediatric Surgery, Kandang Kerbau Women' s and Children' s Hospital (Singapore)

    2002-01-01

    Objective. To investigate the value of CT in complicated childhood pneumonia and its role in early intervention when chest radiography (CXR) is non-contributory. Materials and methods. Forty-two immunocompetent children, aged 1-11 years, admitted for community-acquired pneumonia from October 1997 to September 1999, had 42 contrast-enhanced CT scans and frontal chest radiographs on the same day, which were assessed independently. CT was performed when the patient remained unwell and the CXR images showed failure of resolution despite 7-10 days of antibiotics and/or drainage with urokinase therapy. Results. Compared to CT, CXR revealed suboptimal accuracy rates of lobar involvement (84%), chest tube placement (73%), fluid loculation (42%), abscess formation (40%) and bronchopleural fistulae (33%). It could not assess parenchymal or pleural complications such as cavitary necrosis, early abscess formation, empyemas or pericardial effusions. On the basis of the CT findings and poor clinical progress, 16 patients underwent surgical intervention with the aid of video-assisted thorascopic surgery (VATS). The CT features correlated well with surgical findings. Ten cases required pleural decortication while six with destructive or necrotic lung lesions had surgical resection. Debridement was difficult when the pleura had become thick and fibrotic. Streptococcus pneumoniae was the offending organism in 81% of cases. The right side was affected in 67% of cases. Conclusions. In complicated childhood pneumonia, CT is far superior to CXR in revealing pleural and parenchymal complications, which may require early surgical intervention. (orig.)

  9. CtBP1/BARS Gly172 → Glu mutant structure: Impairing NAD(H)-binding and dimerization

    International Nuclear Information System (INIS)

    Nardini, Marco; Valente, Carmen; Ricagno, Stefano; Luini, Alberto; Corda, Daniela; Bolognesi, Martino

    2009-01-01

    C-terminal binding proteins (CtBPs) are multi-functional proteins involved in nuclear transcriptional co-repression, Golgi membrane fission, and synaptic ribbon formation. Binding of NAD(H) to CtBPs promotes dimerization. CtBP dimers act as a scaffold for multimeric protein complex formation, thus bridging transcriptional repressors and their targets in the nucleus. Based on size-exclusion chromatography experiments and on the crystal structure of the NAD(H)-free G172E CtBP mutant, we show here that absence of NAD(H) induces flexibility/backbone conformational changes at the dimerization interface and at the CtBP interdomain region. The results presented shed first light on the correlation between NAD(H)-binding and functional CtBP dimerization.

  10. RESEARCH ON THE QUALITY INDICATORS OF CURD PRODUCTS BASED ON PROTEIN-HERBAL CLOTS

    Directory of Open Access Journals (Sweden)

    Olena GREK

    2017-12-01

    Full Text Available The article presents the research of qualitative indicators of curd products with different nutritional ingredients based on protein-herbal clots. The effect of the number of Rumex juice and the duration of thermoacid processing on the process of precipitation of milk proteins was determined. It was established that the introduction of vegetative coagulant in the amount (9 ± 0.5% at a temperature (93 ... 95 °C and endurance (3 ... 5 min - provides the optimal yield of protein-herbal clot taking into account restrictions according to organoleptic parameters. The effect of white sugar and apple pectin in fiber on the organoleptic, physico-chemical and rheological indicators curd products was investigated. The dietary fibers increase moisture-proof ability and effective viscosity of samples, and white sugar reduces these indexes due to dehydrating properties. The optimal option is to add to the protein-herbal bunch at the same time two components when mixing - white sugar and apple pectin in fiber in quantities of 15% and 2% respectively. Taking into account the influence of individual non-dairy ingredients - Rumex juice of white sugar and apple pectin in fiber on curd products, the performance of the finished product can purposefully be affected.

  11. Growth-mechanism of giant intracranial aneurysms; demonstration by CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schubiger, O.; Valavanis, A.; Wichmann, W.

    1987-05-01

    In four cases of giant intracranial aneurysm, CT demonstrated a hyperdense open-, or closed-ring structure at the periphery of the aneurysm. Surgery in two of the cases demonstrated that this peripheral hyperdensity represents fresh clot inside the wall of the thrombosed mass. An analogy is established between giant intracranial aneurysms, chronic subdural hematomas and growing encapsulated intracerebral hematomas. The common feature of the three entities is slow growth by recurrent hemorrhages into the lesion. It is proven that growth of chronic subdural hematomas and of growing encapsulated hematomas is related to recurrent hemorrhage from capillaries sprouting within the membrane of the lesion. The highly vascularized membranous wall of a giant intracranial aneurysm seems to behave like the membrane of a chronic subdural hematoma. It is suggested that the giant intracranial aneurysm grows by recurrent hemorrhage into its wall and behaves like growing encapsulated hematomas.

  12. Purification and characterization of a milk-clotting aspartic proteinase from globe artichoke (Cynara scolymus L.).

    Science.gov (United States)

    Llorente, Berta E; Brutti, Cristina B; Caffini, Néstor O

    2004-12-29

    The study of proteinase expression in crude extracts from different organs of the globe artichoke (Cynara scolymus L.) disclosed that enzymes with proteolytic and milk-clotting activity are mainly located in mature flowers. Maximum proteolytic activity was recorded at pH 5.0, and inhibition studies showed that only pepstatin, specific for aspartic proteinases, presented a significant inhibitory effect. Such properties, in addition to easy enzyme inactivation by moderate heating, make this crude protease extract potentially useful for cheese production. Adsorption with activated carbon, together with anion exchange and affinity chromatography, led to the isolation of a heterodimeric milk-clotting proteinase consisting of 30- and 15-kDa subunits. MALDI-TOF MS of the 15-kDa chain determined a 15.358-Da mass, and the terminal amino sequence presented 96% homology with the smaller cardosin A subunit. The amino terminal sequence of the 30-kDa chain proved to be identical to the larger cardosin A subunit. Electrophoresis evidenced proteinase self-processing that was confirmed by immunoblots presenting 62-, 30-, and 15-kDa bands.

  13. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    Directory of Open Access Journals (Sweden)

    Hoffmann Andrew

    2012-11-01

    Full Text Available Abstract Background Low Frequency Vibro-Percussion (LFVP assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy requires study. Methods One hour old clots (n=16 were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen, weighted, interfaced with Heparinized Saline (HS, secured atop a curved dampening base, and photographed. A ~4 cm meat slab was placed over the segment and randomized to receive intermittent LFVP (engaged, - disengaged at 1 second intervals, or no LFVP for 20 minutes. HS was pulsed (~120/80 mmHg, with the diastolic phase coordinated to match LFVP delivery. The segment was then re-photographed and aspirated of fluid to determine post clot weight. The trial was then repeated with 0.5 mls of Streptokinase (15,000 IU/100 microlitre delivered ~ 2 cm upstream from the clot. Results LFVP - HS only samples (vs. controls showed; a development of clot length fluid channels absent in the control group (p Conclusion Diastolic timed LFVP (50 Hz engaged across a chest wall sized barrier enhances clot disruptive effects to an underlying coronary like system.

  14. Analysis of the sacrum: CT with two-dimensional and three-dimensional imaging

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Scott, W.W. Jr.; Brooker, A.F. Jr.

    1987-01-01

    Fifteen patients with sacral lesions were assessed using CT and volumetric 3D image rendering. Lesions imaged included sacral fractures, tumors, osteomyelitis, dysplasia, and sacroiliac diastasis. In all cases, transaxial CT alone was superior to conventional radiographs, and CT with 3D was more clinically useful than CT alone. The 3D real-time video format allows rotation and manipulation in several planes, including the X (spinal) and Z (somersaulting) axes, for optimal visualization of abnormalities. The Z axis gives unique unimpeded inlet, outlet, and ''bird's-eye'' views of the pelvis and sacrum, enhancing detection and characterization of sacral of SI disruptions and subsequent pelvic ring compromise. Because of the ease of assimilating information in such a format, 3D may become the key modality for preoperative planning and for postoperative follow-up

  15. Normal pediatric postmortem CT appearances

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Willemijn M.; Bosboom, Dennis G.H.; Koopmanschap, Desiree H.J.L.M. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Nikkels, Peter G.J. [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Rijn, Rick R. van [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands)

    2015-04-01

    Postmortem radiology is a rapidly developing specialty that is increasingly used as an adjunct to or substitute for conventional autopsy. The goal is to find patterns of disease and possibly the cause of death. Postmortem CT images bring to light processes of decomposition most radiologists are unfamiliar with. These postmortem changes, such as the formation of gas and edema, should not be mistaken for pathological processes that occur in living persons. In this review we discuss the normal postmortem thoraco-abdominal changes and how these appear on CT images, as well as how to differentiate these findings from those of pathological processes. (orig.)

  16. Toward a computational model of hemostasis

    Science.gov (United States)

    Leiderman, Karin; Danes, Nicholas; Schoeman, Rogier; Neeves, Keith

    2017-11-01

    Hemostasis is the process by which a blood clot forms to prevent bleeding at a site of injury. The formation time, size and structure of a clot depends on the local hemodynamics and the nature of the injury. Our group has previously developed computational models to study intravascular clot formation, a process confined to the interior of a single vessel. Here we present the first stage of an experimentally-validated, computational model of extravascular clot formation (hemostasis) in which blood through a single vessel initially escapes through a hole in the vessel wall and out a separate injury channel. This stage of the model consists of a system of partial differential equations that describe platelet aggregation and hemodynamics, solved via the finite element method. We also present results from the analogous, in vitro, microfluidic model. In both models, formation of a blood clot occludes the injury channel and stops flow from escaping while blood in the main vessel retains its fluidity. We discuss the different biochemical and hemodynamic effects on clot formation using distinct geometries representing intra- and extravascular injuries.

  17. Value of the quantity and distribution of subarachnoid haemorrhage on CT in the localization of ruptured cerebral aneurysm

    International Nuclear Information System (INIS)

    Karttunen, A.I.; Jartti, P.H.; Haapea, M.; Ukkola, V.A.; Sajanti, J.

    2003-01-01

    Computed tomography (CT) is the 'gold standard' for detecting subarachnoid haemorrhage (SAH) and digital subtraction angiography (DSA) for visualising the vascular pathology. We studied retrospectively 180 patients with subarachnoid haemorrhage (SAH) who underwent first non-enhanced computed tomography (CT), then digital subtraction angiography (DSA) and finally operative aneurysm clipping. Our aim was to assess if the location of the ruptured aneurysm could be predicted on the basis of the quantity and distribution of haemorrhage on the initial CT scan. 180 patients with SAH were retrospectively studied. All the CT and DSA examinations were performed at the same hospital. CT was performed within 24 hours after the initial haemorrhage. DSA was performed alter the CT, within 48 hours after the initial haemorrhage. Two neuroradiologists, blind to the DSA results, analysed and scored independently the quantity and distribution of the haemorrhage and predicted the site of the ruptured aneurysm on the basis of the non-enhanced CT. DSA provided the location of the ruptured aneurysm. All the patients were operated upon, and the location of the ruptured aneurysm was determined. The overall reliability value (r,-value) between the two neuroradiologists for locating all ruptured aneurysms was 0.780. The corresponding value for the right MCA was 0.911, that for the left MCA 0.877 and that for the AcoA 0.736. Not all of the rc-values were calculated, either because the location of the rupture was constant or because the number of ruptures in the vessel was too small. Subarachnoid haemorrhage with a parenchymal hematoma is an excellent predictor of the site of the ruptured aneurysm with a statistical significance of p = 0.003. The quantity and pattern of the blood clot an CT within the day of onset of SAH is a reliable and quick cool for locating a ruptured MCA or AcoA aneurysm. It is not, however, reliable for locating other ruptured aneurysms. Subarachnoid haemorrhage with a

  18. Basilar artery occlusion: Prognostic signs of severity on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: pierre-alexandre.poletti@hcuge.ch [Service of Radiology, University Hospital of Geneva (Switzerland); Pereira, Vitor Mendes [Service of Neuroradiology, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211 Geneva (Switzerland); Department of Medical Imaging, University of Toronto (Canada); Department of Surgery, University of Toronto (Canada); Lovblad, Karl-Olof [Service of Neuroradiology, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211 Geneva (Switzerland); Canel, Lucie [Service of Radiology, University Hospital of Geneva (Switzerland); Sztajzel, Roman [Service of Neurology, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211 Geneva (Switzerland); Becker, Minerva [Service of Radiology, University Hospital of Geneva (Switzerland); Perneger, Thomas [Division of Clinical Epidemiology, University Hospital of Geneva, 4 rue Gabrielle-Perret-Gentil, 1211 Geneva (Switzerland); Platon, Alexandra [Service of Radiology, University Hospital of Geneva (Switzerland)

    2015-07-15

    Highlights: • The main CT signs associated with basilar artery occlusion were analyzed. • CT sign of acute ischemic lesion is significantly associated with a bad outcome. • The site of the basilar artery occlusion is not associated to the patients’ outcome. - Abstract: Purpose: To determine the computed tomography (CT) signs that are predictive of the clinical outcome of basilar artery occlusion (BAO). Materials and methods: The study population consisted in 37 patients (14 women, 23 men, mean age: 63 years), admitted with onset of neurological deficit, starting 1–72 h prior to admission, who were diagnosed with BAO on the basis of a CT examination with intravenous contrast agent. The following signs were collected on CT scans performed on admission: clot density on noncontrast images, clot length, and clot location, as well as the presence of acute ischemic lesions. The results were compared against the modified Rankin Scale (mRS) score of patients at 3 months, favorable clinical outcome being defined as a mRS score ≤3. Results: The clinical outcome was favorable in 13 (35%) of the 37 patients and unfavorable in 24 (65%). Signs of acute ischemia were visible in 13 of the 24 patients with unfavorable outcome but in none of the 13 patients with favorable outcome (p < 0.001). None of the other CT signs analyzed were significantly correlated with clinical prognosis. Conclusion: Of all the CT signs analyzed, only the presence of signs of acute ischemia on the admission CT of patients with BAO was associated with poor prognosis.

  19. Tranexamic acid combined with recombinant factor VIII increases clot resistance to accelerated fibrinolysis in severe hemophilia A

    DEFF Research Database (Denmark)

    Hvas, Anne-Mette; Sørensen, Hanne Thykjær; Norengaard, Lisbeth

    2007-01-01

    examined whether the clot stability in hemophiliacs could be improved by treatment with tranexamic acid (TXA) in combination with recombinant factor VIII (rFVIII). PATIENTS/METHODS: Baseline blood samples were obtained from eight males with severe hemophilia A. Thereafter, a bolus injection of r...

  20. In vitro effect of hemodilution on activated clotting time and high-dose thrombin time during cardiopulmonary bypass

    NARCIS (Netherlands)

    Huyzen, RJ; vanOeveren, W; Wei, FY; Stellingwerf, P; Boonstra, PW; Gu, YJ

    Background. Extreme dilution of clotting factors, as may occur during pediatric or neonatal cardiopulmonary bypass, often leads to inadequate monitoring of anticoagulation with activated dotting time (ACT). In this study we postulate that the high-dose thrombin time (HiTT) is less influenced by

  1. Fibrinolytic Activity and Dose-Dependent Effect of Incubating Human Blood Clots in Caffeic Acid Phenethyl Ester: In Vitro Assays

    Directory of Open Access Journals (Sweden)

    Abuzar Elnager

    2015-01-01

    Full Text Available Background. Caffeic acid phenethyl ester (CAPE has been reported to possess time-dependent fibrinolytic activity by in vitro assay. This study is aimed at investigating fibrinolytic dose-dependent activity of CAPE using in vitro assays. Methods. Standardized human whole blood (WB clots were incubated in either blank controls or different concentrations of CAPE (3.75, 7.50, 15.00, 22.50, and 30.00 mM. After 3 hours, D-dimer (DD levels and WB clot weights were measured for each concentration. Thromboelastography (TEG parameters were recorded following CAPE incubation, and fibrin morphology was examined under a confocal microscope. Results. Overall, mean DD (μg/mL levels were significantly different across samples incubated with different CAPE concentrations, and the median pre- and postincubation WB clot weights (grams were significantly decreased for each CAPE concentration. Fibrin removal was observed microscopically and indicated dose-dependent effects. Based on the TEG test, the Ly30 fibrinolytic parameter was significantly different between samples incubated with two different CAPE concentrations (15.0 and 22.50 mM. The 50% effective dose (ED50 of CAPE (based on DD was 1.99 mg/mL. Conclusions. This study suggests that CAPE possesses fibrinolytic activity following in vitro incubation and that it has dose-dependent activities. Therefore, further investigation into CAPE as a potential alternative thrombolytic agent should be conducted.

  2. Dual-energy perfusion-CT in recurrent pancreatic cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, F.; Skornitzke, S.; Kauczor, H.U.; Stiller, W.; Klauss, M. [Heidelberg Univ. (Germany). Clinic of Diagnostic and Interventional Radiology; Hackert, T. [Heidelberg Univ. (Germany). Clinic of Surgery; Grenacher, L. [Diagnostik Muenchen (Germany). Diagnostic Imaging Center

    2016-06-15

    To evaluate the diagnostic performance of dual energy (DE) perfusion-CT for the differentiation between postoperative soft-tissue formation and tumor recurrence in patients after potentially curative pancreatic cancer resection. 24 patients with postoperative soft-tissue formation in the conventional regular follow-up CT acquisition after pancreatic cancer resection with curative intent were included prospectively. They were examined with a 64-row dual-source CT using a dynamic sequence of 34 DE acquisitions every 1.5 s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). Weighted average (linearly blended M0.5) 120 kVp-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool for estimating blood flow, permeability, and blood volume. Diagnosis was confirmed by histological study (n=4) and by regular follow-up. Final diagnosis was local recurrence of pancreatic cancer in 15 patients and unspecific postoperative tissue formation in 9 patients. The blood-flow values for recurrence tissue trended to be lower compared to postoperative tissue formation with 16.6 ml/100 ml/min and 24.7 ml/100 ml/min, respectively for weighted average 120 kVp-equivalent image data, which was not significant (n.s.) (p=0.06, significance level 0.05). Permeability- and blood-volume values were only slightly lower in recurrence tissue (n.s.). DE perfusion-CT is feasible in patients after pancreatic cancer resection and a promising functional imaging technique. As only a trend for lower perfusion values in local recurrence compared to unspecific postoperative alterations was found, the perfusion differences are not yet sufficient to differentiate between malignancy and unspecific postoperative alterations for this new technique. Further studies and technical improvements are needed to generate reliable data for this clinically highly relevant differentiation.

  3. Postoperative assessment of surgical results using three dimensional surface reconstruction CT (3D-CT) in a craniofacial anomaly

    International Nuclear Information System (INIS)

    Nishimura, Jiro; Sato, Kaoru; Nishimoto, Hiroshi; Tsukiyama, Takashi; Fujioka, Mutsuhisa; Akagawa, Tetsuya.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three dimensional (3D) born and soft tissue surfaces, given a high resolution CT scan-series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephaloceles, and musculoskeletal anomalies. In this study, a postoperative assessment of the craniofacial surgical results has been accomplished using this 3D-CT in 2 children with craniofacial dysmorphism. The authors discuss the advantages of this 3D-CT imaging method in the postoperative assessments of craniofacial anomalies. Results are detailed in the following listing : 1) a postoperative 3D-CT reveals the anatomical details corrected by the craniofacial surgery more precisely and stereographically than conventional radiological methods ; 2) secondary changes of the cranium after the surgery, such as bony formation in the area of the osteotomy and postoperative asymmetric deformities, are detected early by the 3D-CT imaging technique, and, 3) 3D-CT mid-sagittal and top axial views of the intracranial skull base are most useful in postoperative assessments of the surgical results. Basesd on our experience, we expect that three dimensional surface reconstructions from CT scans will become to be used widely in the postoperative assessments of the surgical results of craniofacial anomalies. (author)

  4. Random Forests Are Able to Identify Differences in Clotting Dynamics from Kinetic Models of Thrombin Generation.

    Science.gov (United States)

    Arumugam, Jayavel; Bukkapatnam, Satish T S; Narayanan, Krishna R; Srinivasa, Arun R

    2016-01-01

    Current methods for distinguishing acute coronary syndromes such as heart attack from stable coronary artery disease, based on the kinetics of thrombin formation, have been limited to evaluating sensitivity of well-established chemical species (e.g., thrombin) using simple quantifiers of their concentration profiles (e.g., maximum level of thrombin concentration, area under the thrombin concentration versus time curve). In order to get an improved classifier, we use a 34-protein factor clotting cascade model and convert the simulation data into a high-dimensional representation (about 19000 features) using a piecewise cubic polynomial fit. Then, we systematically find plausible assays to effectively gauge changes in acute coronary syndrome/coronary artery disease populations by introducing a statistical learning technique called Random Forests. We find that differences associated with acute coronary syndromes emerge in combinations of a handful of features. For instance, concentrations of 3 chemical species, namely, active alpha-thrombin, tissue factor-factor VIIa-factor Xa ternary complex, and intrinsic tenase complex with factor X, at specific time windows, could be used to classify acute coronary syndromes to an accuracy of about 87.2%. Such a combination could be used to efficiently assay the coagulation system.

  5. Random Forests Are Able to Identify Differences in Clotting Dynamics from Kinetic Models of Thrombin Generation.

    Directory of Open Access Journals (Sweden)

    Jayavel Arumugam

    Full Text Available Current methods for distinguishing acute coronary syndromes such as heart attack from stable coronary artery disease, based on the kinetics of thrombin formation, have been limited to evaluating sensitivity of well-established chemical species (e.g., thrombin using simple quantifiers of their concentration profiles (e.g., maximum level of thrombin concentration, area under the thrombin concentration versus time curve. In order to get an improved classifier, we use a 34-protein factor clotting cascade model and convert the simulation data into a high-dimensional representation (about 19000 features using a piecewise cubic polynomial fit. Then, we systematically find plausible assays to effectively gauge changes in acute coronary syndrome/coronary artery disease populations by introducing a statistical learning technique called Random Forests. We find that differences associated with acute coronary syndromes emerge in combinations of a handful of features. For instance, concentrations of 3 chemical species, namely, active alpha-thrombin, tissue factor-factor VIIa-factor Xa ternary complex, and intrinsic tenase complex with factor X, at specific time windows, could be used to classify acute coronary syndromes to an accuracy of about 87.2%. Such a combination could be used to efficiently assay the coagulation system.

  6. THE FLOCCULATION MAXIMUM (pH) OF FIBRINOGEN AND SOME OTHER BLOOD-CLOTTING REAGENTS. (RELATIVE TURBIDIMETRY WITH THE EVELYN PHOTOELECTRIC COLORIMETER).

    Science.gov (United States)

    Ferguson, J H

    1942-03-20

    By means of a novel adaptation of the Evelyn photoelectric colorimeter to the measurement of relative turbidities, the question of the flocculation maximum (F.M.) in acetate buffer solutions of varying pH and salt content has been studied on (a) an exceptionally stable prothrombin-free fibrinogen and its solutions after incipient thermal denaturation and incomplete tryptic proteolysis, (b) plasma, similarly treated, (c) prothrombin, thrombin, and (brain) thromboplastin solutions. All the fibrinogens show a remarkable uniformity of the precipitation pattern, viz. F.M. =4.7 (+/-0.2) pH in salt-containing buffer solutions and pH = 5.3 (+/-0.2) in salt-poor buffer (N/100 acetate). The latter approximates the isoelectric point (5.4) obtained by cataphoresis (14). There is no evidence that denaturation or digestion can produce any "second maximum." The data support the view that fibrin formation (under the specific influence of thrombin) is intrinsically unrelated to denaturation and digestion phenomena, although all three can proceed simultaneously in crude materials. A criticism is offered, therefore, of Wöhlisch's blood clotting theory. Further applications of the photoelectric colorimeter to coagulation problems are suggested, including kinetic study of fibrin formation and the assay of fibrinogen, with a possible sensitivity of 7.5 mg. protein in 100 cc. solution.

  7. CT diagnosis of thyroid carcinoma

    International Nuclear Information System (INIS)

    Luo Dehong; Shi Mulan; Luo Douqiang

    1998-01-01

    Purpose: To study the CT appearances of thyroid carcinoma and its cervical metastatic lymphadenopathy, as well as to evaluate the diagnostic criteria of tumor invasion of adjacent structures. Methods: CT findings of surgery and pathology proved thyroid carcinoma in 52 patients were analyzed. Results: All of the primary tumor were heterogeneous in density, 32 tumors (82.5%) were ill-defined. Fine granular calcifications were revealed in 11 primary tumors and metastatic lymph nodes in 5 cases. Cystic formation with intracystic high density papillary-like nodules were found in 4 primary tumors and metastatic lymphadenopathy in 5 cases. Trachea, esophagus and carotic artery invasion were proved by surgery in 22, 21 and 10 cases respectively. Serrated inner wall and tumor nodule protrusion into tracheal lumen were the definite signs of trachea invasion. Use tumor encasement over 1/2 of the circumference of esophagus and 1/3 of the circumference of carotid artery as the diagnostic criterion of invasion, sensitivity was 71.4%, 100.0% specificity was 96.3%, 95.2% respectively. Conclusion: Fine granular calcification and cystic formation with high attenuation intracystic papillary-like nodules were characteristic manifestations of primary thyroid carcinoma (especially papillary carcinoma) and its metastatic lymphadenopathy as well. Contrast enhanced CT scan is helpful in the diagnosis of thyroid carcinoma and the delineation of tumor extent, which is very important in surgical planning

  8. Biological activity analysis of native and recombinant streptokinase using clot lysis and chromogenic substrate assay.

    Science.gov (United States)

    Mahboubi, Arash; Sadjady, Seyyed Kazem; Mirzaei Saleh Abadi, Mohammad; Azadi, Saeed; Solaimanian, Roya

    2012-01-01

    DETERMINATION OF STREPTOKINASE ACTIVITY IS USUALLY ACCOMPLISHED THROUGH TWO ASSAY METHODS: a) Clot lysis, b) Chromogenic substrate assay. In this study the biological activity of two streptokinase products, namely Streptase®, which is a native product and Heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned assay methods. The results indicated that whilst the activity of Streptase® was found to be 101 ± 4% and 97 ± 5% of the label claim with Clot lysis and Chromogenic substrate assay respectively, for Heberkinasa® the potency values obtained were 42 ± 5% and 92.5 ± 2% of the label claim respectively. To shed some light on the reason for this finding, the n-terminal sequence of the streptokinase molecules present in the two products was determined. The results showed slight differences in the amino acid sequence of the recombinant product in comparison to the native one at the amino terminus. This finding supports those of other workers who found that n-terminal sequence of the streptokinase molecule can have significant effect on the activity of this protein.

  9. Heat transfer analysis on peristaltically induced motion of particle-fluid suspension with variable viscosity: Clot blood model.

    Science.gov (United States)

    Bhatti, M M; Zeeshan, A; Ellahi, R

    2016-12-01

    In this article, heat transfer analysis on clot blood model of the particle-fluid suspension through a non-uniform annulus has been investigated. The blood propagating along the whole length of the annulus was induced by peristaltic motion. The effects of variable viscosity and slip condition are also taken into account. The governing flow problem is modeled using lubrication approach by taking the assumption of long wavelength and creeping flow regime. The resulting equation for fluid phase and particle phase is solved analytically and closed form solutions are obtained. The physical impact of all the emerging parameters is discussed mathematically and graphically. Particularly, we considered the effects of particle volume fraction, slip parameter, the maximum height of clot, viscosity parameter, average volume flow rate, Prandtl number, Eckert number and fluid parameter on temperature profile, pressure rise and friction forces for outer and inner tube. Numerical computations have been used to determine the behavior of pressure rise and friction along the whole length of the annulus. The present study is also presented for an endoscope as a special case of our study. It is observed that greater influence of clot tends to rise the pressure rise significantly. It is also found that temperature profile increases due to the enhancement in Prandtl number, Eckert number, and fluid parameter. The present study reveals that friction forces for outer tube have higher magnitude as compared to the friction forces for an inner tube. In fact, the results for present study can also be reduced to the Newtonian fluid by taking ζ → ∞. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  11. Growth of hydroxyapatite on physiologically clotted fibrin capped gold nanoparticles

    International Nuclear Information System (INIS)

    Sastry, T P; Sundaraseelan, J; Swarnalatha, K; Sobhana, S S Liji; Makheswari, M Uma; Sekar, S; Mandal, A B

    2008-01-01

    The growth of hydroxyapatite (HAp) on physiologically clotted fibrin (PCF)-gold nanoparticles is presented for the first time by employing a wet precipitation method. Fourier transform infrared (FTIR) spectroscopy confirmed the characteristic functionalities of PCF and HAp in the PCF-Au-HAp nanocomposite. Scanning electron microscopy (SEM) images have shown cuboidal nanostructures having a size in the range of 70-300 nm of HAp, whereas 2-50 nm sized particles were visualized in high-resolution transmission electron microscopy (TEM). Energy-dispersive x-ray (EDX) and x-ray diffraction (XRD) studies have confirmed the presence of HAp. These results show that gold nanoparticles with PCF acted as a matrix for the growth of HAp, and that PCF-Au-HAp nanocomposite is expected to have better osteoinductive properties

  12. CT perfusion assessment of treatment response and complications in acute ischemic stroke

    NARCIS (Netherlands)

    Horsch, AD

    2016-01-01

    An acute ischemic stroke is caused by the sudden occlusion of a large blood vessel to a part of the brain. Current treatment options are to dissolve the clot with the injection of a solvent into a vein or to physically remove the clot with an interventional radiology procedure. A major complication

  13. Comparison of clot lysis activity and biochemical properties of originator tenecteplase (Metalyse® with those of an alleged biosimilar

    Directory of Open Access Journals (Sweden)

    Werner eKliche

    2014-02-01

    Full Text Available The bioengineered tissue plasminogen activator tenecteplase is an important treatment modality of acute myocardial infarction recommended by international guidelines. Following introduction of originator tenecteplase (brand names Metalyse® and TNKase®, a ‘biosimilar’ tenecteplase became available for commercial use in India under the brand name Elaxim® in the absence of Indian biosimilar guidelines which came into force from September 15th, 2012. Based on a report of biochemical and fibrinolytical differences between Metalyse and Elaxim, we have systematically compared them in a range of routine quality testing assays. As compared to Metalyse, Elaxim exhibited less clot lysis activity and contained less of the two-chain form of tenecteplase. Even upon full in vitro conversion to the two-chain form Elaxim exhibited less clot lysis activity. This was linked to differences in sialic acid content and glycosylation pattern with Elaxim exhibiting less bi- and more tetra-antennary glycosylation, leading to different charge heterogeneity profile. Regarding purity, Elaxim contained more tenecteplase aggregates and, in contrast to Metalyse, considerable amounts of Chinese hamster ovary cell protein. Taken together these data demonstrate that Metalyse and Elaxim differ considerably in clot lysis activity and biochemical properties. These data question whether Elaxim indeed can be considered a ‘biosimilar’ of Metalyse, i.e. whether and to which extent the clinical efficacy and safety properties of Metalyse can be extrapolated to Elaxim in the absence of comparative clinical data.

  14. Electrokinetic and Hemostatic Profiles of Nonwoven Cellulosic/Synthetic Fiber Blends with Unbleached Cotton

    Directory of Open Access Journals (Sweden)

    J. Vincent Edwards

    2014-11-01

    Full Text Available Greige cotton contains waxes and pectin on the outer surface of the fiber that are removed when bleached, but these components present potential wound dressing functionality. Cotton nonwovens blended with hydrophobic and hydrophilic fibers including viscose, polyester, and polypropylene were assessed for clotting activity with thromboelastography (TEG and thrombin production. Clotting was evaluated based on TEG measurements: R (time to initiation of clot formation, K (time from end of R to a 20 mm clot, α (rate of clot formation according to the angle tangent to the curve as K is reached, and MA (clot strength. TEG values correlate to material surface polarity as measured with electrokinetic parameters (ζplateau, Δζ and swell ratio. The material surface polarity (ζplateau varied from −22 to −61 mV. K values and thrombin concentrations were found to be inversely proportional to  ζplateau with an increase in material hydrophobicity. An increase in the swell ratios of the materials correlated with decreased K values suggesting that clotting rates following fibrin formation increase with increasing material surface area due to swelling. Clot strength (MA also increased with material hydrophobicity. Structure/function implications from the observed clotting physiology induced by the materials are discussed.

  15. Abdominal lymphadenopathy in tuberculosis and lymphoma: Differentiation with CT

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Choi, Byung Ihn; Han, Joon Koo; Han, Man Chung; Song, Chi Sung; Yang, Seoung Oh

    1993-01-01

    Tuberculosis and lymphoma, these 2 dieases can present with lymphadenopathy in anywhere of the body. Therefore differentiation of tuberculosis from lymphoma is often difficult. CT scans of 17 patients with tuberculosis and 23 patients with lymphoma were retrospectively reviewed to evaluate the efficacy of CT scans in differentating adenopathy between tuberculosis and lymphoma. All the patients underwent abdominal CT scans with contrast enhancement before treatment. The size, internal architecture, distribution of lymph nodes, and associated findings on CT scans were analyzed. As compared with lymphoma, tuberculous lymphadenopathy showed 1) female preponderance (65%), 2) predilection for percolative lymph nodes (47%), 3) internal low attenuation in lymph nodes (82%), 4) cold abscess formation (24%). Characteristics of lymphoma on CT scans include 1) male preponderance (78%), 2) conglomeration of lymph nodes (39%), 3) homogeneous internal lymph node structure (83%). These results suggest that evaluation of the cahracteristics of lymphadenopathy on CT scans is helpful for differentiating between tuberculousis and lymphoma

  16. Metastatic liver tumor from cystic ovarian carcinomas. CT and MRI appearance

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi; Yamashita, Yasuyuki; Ogata, Ichiro; Namimoto, Tomohiro; Abe, Yasuko; Urata, Joji; Takahashi, Mutsumasa [Kumamoto Univ. (Japan). School of Medicine

    1999-08-01

    The initial and follow-up CT and MRI images of ten patients with hepatic metastases from ovarian tumors were retrospectively analyzed to establish their features and sequential changes in appearance. Ten patients with hepatic metastasis from ovarian tumors received initial and follow-up CT and MRI examinations. Six patients were followed up every two to three weeks before surgical tumor resection. Both CT and MR images were analyzed by two radiologists. A total of fourteen lesions were detected by CT and MRI in 10 patients. All 14 lesions were demonstrated as areas of marked hyperintensity on T2-weighted MRI. Eleven cyst-like tumors were demonstrated as round or oval low density lesions on CT and as areas of hypointensity on T1-weighted imaging. Three lesions were shown as solid masses with slightly low attenuation at the initial CT examination and slightly low or iso-intensity areas on T1-weighted imaging, and these lesions showed early peripheral globular enhancement and delayed enhancement on contrast-enhanced CT and MR imaging. Cystic formation was observed two to three weeks later after initial study in all the 3 solid lesions. Rapid subcapsular effusion, which showed obvious enhancement on delayed Gd-DTPA enhanced MR imaging, was observed in two patients. The hepatic metastatic tumor from cystic ovarian carcinoma may manifest as a well-defined cystic lesion or as a solid mass, and the solid mass shows delayed enhancement on contrast-enhanced CT and MR imaging. Furthermore, rapid cystic formation and rapid subcapsular extension is frequently seen. (author)

  17. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  18. A comparative evaluation of the blood clot, platelet-rich plasma, and platelet-rich fibrin in regeneration of necrotic immature permanent teeth: A clinical study

    Directory of Open Access Journals (Sweden)

    Isha Narang

    2015-01-01

    Full Text Available Introduction: This study was designed as a clinical trial to evaluate and compare the regenerative potential of platelet-rich fibrin (PRF, platelet-rich plasma (PRP, and blood clot in immature necrotic permanent teeth with or without associated apical periodontitis. Methods: Access preparation was done under rubber dam isolation. Copious irrigation was done with 2.5% NaOCl and triple antibiotic paste was placed as an intracanal medicament. After 4 weeks, the cases were divided into four groups with five patients in each group. The study design had three test arms and one control arm. Group I in which mineral trioxide aggregate apexification was carried out and it was kept as control group to evaluate the regenerative potential of blood clot and platelet concentrates, Group II in which blood clot was used as scaffold in the canal, Group III in PRF was used as scaffold, and Group IV in which PRP carried on collagen was used as a scaffold. Results: The clinical and radiographic evaluation after 6 and 18 months was done by two independent observers who were blinded from the groups. The scoring was done as: None score was denoted by, Fair by 1, Good by 2, and Excellent by 3. The data were then analyzed statistically by Fisher′s exact test using Statistics and Data 11.1(PRP Using harvest Smart PReP2 which showed statistically significant values in Group III as compared to other Groups. Conclusion: PRF has huge potential to accelerate the growth characteristics in immature necrotic permanent teeth as compared to PRP and blood clot.

  19. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  20. Degenerative osteoarthritis of atlanto-odontoid joint: CT findings and clinical analysis

    International Nuclear Information System (INIS)

    Xu Aide; Wang Song; Mao Yunhua

    1998-01-01

    Purpose: To analyze the CT appearances and clinical aspects of the degeneration at atlanto-odontoid(A-O) joint. Methods: Thin section axial CT scans, of AO joints were studied in 317 consecutive patients who underwent brain or cervical spine CT examinations. The images were viewed using double-blind method. Observation included: osteophytosis, changes of joint space and transverse ligament, and the clinical symptoms as well. Results: CT findings of AO joint degeneration included: formation of osteophyte, narrowing of joint space, transverse ligament calcification, and joint vacuum phenomenon. Among individuals above 40 years of age, the incidence of degeneration at AO joint went up gradually (P<0.01). Conclusion: Degeneration of AO joint was not uncommon among aged people, CT could better demonstrate the pathological changes

  1. An approach for quantitative image quality analysis for CT

    Science.gov (United States)

    Rahimi, Amir; Cochran, Joe; Mooney, Doug; Regensburger, Joe

    2016-03-01

    An objective and standardized approach to assess image quality of Compute Tomography (CT) systems is required in a wide variety of imaging processes to identify CT systems appropriate for a given application. We present an overview of the framework we have developed to help standardize and to objectively assess CT image quality for different models of CT scanners used for security applications. Within this framework, we have developed methods to quantitatively measure metrics that should correlate with feature identification, detection accuracy and precision, and image registration capabilities of CT machines and to identify strengths and weaknesses in different CT imaging technologies in transportation security. To that end we have designed, developed and constructed phantoms that allow for systematic and repeatable measurements of roughly 88 image quality metrics, representing modulation transfer function, noise equivalent quanta, noise power spectra, slice sensitivity profiles, streak artifacts, CT number uniformity, CT number consistency, object length accuracy, CT number path length consistency, and object registration. Furthermore, we have developed a sophisticated MATLAB based image analysis tool kit to analyze CT generated images of phantoms and report these metrics in a format that is standardized across the considered models of CT scanners, allowing for comparative image quality analysis within a CT model or between different CT models. In addition, we have developed a modified sparse principal component analysis (SPCA) method to generate a modified set of PCA components as compared to the standard principal component analysis (PCA) with sparse loadings in conjunction with Hotelling T2 statistical analysis method to compare, qualify, and detect faults in the tested systems.

  2. Effect of homogenization and heat treatment on the behavior of protein and fat globules during gastric digestion of milk.

    Science.gov (United States)

    Ye, Aiqian; Cui, Jian; Dalgleish, Douglas; Singh, Harjinder

    2017-01-01

    The effects of homogenization and heat treatment on the formation and the breakdown of clots during gastric digestion of whole milk were investigated using a human gastric simulator. Homogenization and heat treatment led to formation of coagula with fragmented and crumbled structures compared with the coagulum formed from raw whole milk, but a larger fraction of the protein and more fat globules were incorporated into the coagula induced by action of the milk-clotting enzyme pepsin. The fat globules in the whole milk appeared to be embedded in the clots as they formed. After formation of the clot, the greater numbers of pores in the structures of the clots formed with homogenized milk and heated whole milk led to greater rates of protein hydrolysis by pepsin, which resulted in faster release of fat globules from the clots into the digesta. Coalescence of fat globules occurred both in the digesta and within the protein clots no matter whether they were in homogenized or heated milk samples. The formation of clots with different structures and hence the changes in the rates of protein hydrolysis and the release of milk fat into the digesta in the stomach provide important information for understanding the gastric emptying of milk and the potential to use this knowledge to manipulate the bioavailability of fat and other fat-soluble nutrients in dairy products. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. An experimental setup to evaluate innovative therapy options for the enhancement of bone healing using BMP as a benchmark – a pilot study

    Directory of Open Access Journals (Sweden)

    B Preininger

    2012-04-01

    Full Text Available Critical or delayed bone healing in rat osteotomy (OT models is mostly achieved through large defects or instability. We aimed to design a rat OT model for impaired bone healing based on age, gender and parity. The outcome should be controllable through variations of the haematoma in the OT including a bone morphogenetic protein (BMP 2 guided positive control.Using external fixation to stabilise femoral a 2 mm double OT in 12 month old, female Sprague Dawley rats after a minimum of 3 litters healing was characterised following in situ haematoma formation (ISH-group, transplantation of a BMP charged autologous blood clot (BMP-group and the artificial blood clot only (ABC-group into the OT-gap. In vivo micro-computer tomography (µCT scans were performed after 2, 4 and 6 weeks. After 6 weeks specimens underwent histological analyses.In µCT examinations and histological analyses no bony bridging was observed in all but one animal in the ISH-group. In the BMP group complete bridging was achieved in all animals. The ABC-group showed less mineralised tissue formation and smaller bridging scores during the course of healing than the ISH-group.In this pilot study we introduce a model for impaired bone healing taking the major biological risk factors into account. We could show that the in situ fracture haematoma is essential for bone regeneration. Using BMP as a positive control the presented experimental setup can serve to evaluate innovative therapeutical concepts in long bone application.

  4. Thrombin generation assay as a possible tool for assessment of reduced activity of clotting factors induced by antiphospholipid antibodies and in-vitro evaluation of treatment options.

    Science.gov (United States)

    Livnat, Tami; Zivelin, Ariella; Tamarin, Ilia; Guetta, Victor; Salomon, Ophira

    2009-12-01

    Bleeding is a rare manifestation of antiphospholipid syndrome, unless associated with reduced clotting factors or severe thrombocytopenia. Accurate assessment of the autoantibodies in plasma is very important since the autoantibodies can lead to bleeding or thrombosis. The objective of the present study was to define the inhibitors causing reduced clotting activity in a patient with antiphospholipids antibodies and to assess the potential of thrombin generation assay to assist in establishment of optimal treatment in case of major bleeding. Levels of clotting factors as well as inhibitors to factors II, V, VII, VIII, IX, X and XI were defined. For detection of inhibitors to prothrombin crossed immunoelectrophoresis was used. IgG was purified by commercial protein A column. Thrombin generation was measured using a fluorometric assay in platelet-poor and platelet-rich plasma. Inhibitors toward the activity of factors V, VII, VIII, IX, X and XI were defined and also an inhibitor to prothrombin antigen. No thrombin generation was induced in the patient's plasma by recalcification even in the presence of recombinant factor VIIa or factor VIII inhibitor bypassing activity. In contrast, addition of platelets from either donor or patient or synthetic phospholipids normalized the thrombin generation. The thrombin generation model showed that the addition of platelets and no recombinant factor VIIa or factor VIII inhibitor bypassing activity would correct thrombin generation in vitro. On this basis, platelet concentrates were administered to a patient with bleeding caused by lupus anticoagulant and low clotting factors activity.

  5. Enzymatic milk clotting activity in artichoke (Cynara scolymus) leaves and alpine thistle (Carduus defloratus) flowers. Immobilization of alpine thistle aspartic protease.

    Science.gov (United States)

    Esposito, Marilena; Di Pierro, Prospero; Dejonghe, Winnie; Mariniello, Loredana; Porta, Raffaele

    2016-08-01

    Two different milk clotting enzymes, belonging to the aspartic protease family, were extracted from both artichoke leaves and alpine thistle flowers, and the latter was covalently immobilized by using a polyacrylic support containing polar epoxy groups. Our findings showed that the alpine thistle aspartic protease was successfully immobilized at pH 7.0 on Immobeads IB-150P beads and that, under these experimental conditions, an immobilization yield of about 68% and a recovery of about 54% were obtained. Since the enzyme showed an optimal pH of 5.0, a value very similar to the one generally used for milk clotting during cheese making, and exhibited a satisfactory stability over time, the use of such immobilized vegetable rennet for the production of novel dairy products is suggested. Copyright © 2016. Published by Elsevier Ltd.

  6. Dynamic CT in the abdominal organ, 1

    International Nuclear Information System (INIS)

    Fukuda, Kunihiko

    1980-01-01

    By utilizing a 4.5-second CT (computed tomography) scanner which allows sequential scans the changes of the iodine concentration in abdominal organs can be observed as dynamics reflected in CT number. The abdominal dynamic CT was performed as following method. After performing the preliminary scan 50ml of 60% meglumine iothalamate was rapidly injected intravenously by hands. The sequential scanning was initiated when a half dose of contrast medium was injected. In completion of the 4 sequential scans under arrested respiration the conventional post contrast scanning was performed. The analysis of 112 cases dynamically studied by CT came to the following conclusion. CT number of the abdominal aorta was greatest on the 1st or 2nd scan of the sequential scans (7.5 - 20.5 seconds after initiation of injection). Following this peak formation, CT number of the abdominal aorta declined rapidly due to both prompt diffusion of contrast medium into the extravascular space and dilution by the intravascular fluid. Iodine concentration of the abdominal aorta during the peak period was calculated as 11.3 mg/ml by the present method, being theoretically sufficient for delineation of the vessels smaller than medium size. In the patients with impaired renal function, several characteristic patterns were noted on the dynamics of contrast medium within the abdominal organs. The abdominal dynamic CT was felt to be promissing for evaluation of the renal function. (author)

  7. Studies on cytotoxic and clot lysis activity of probiotically fermented cocktail juice prepared using Camellia sinensis and Punica grantum

    Science.gov (United States)

    Biswas, Ananya; Deori, Meenakshi; Nivetha, A.; Mohansrinivasan, V.

    2017-11-01

    In the current research the effect of probiotic microorganisms viz; Lactococcus lactis and Lactobacillus plantarum on fermentation of Camellia sinensis and Punica grantum was studied. In vitro test were done to analyze the anticancer, antioxidant and atherosclerosis (clot lysis) properties of fermented juice. The juice was fermented for 48 and 96h, during which concentration of phenolic content, total acid content and free radical scavenging activity of the sample was analyzed by DPPH assay (α, α-diphenyl-β-picrylhydrazyl). Dropping of pH was observed after 48 h of fermentation. The clot lysis activity was found to be 80 % in 100μl concentration of fermented cocktail juice. The 96 h fermented sample has shown around 70% inhibition against colon cancer cell lines. Analytical study of HPLC proves the organic acid production such as ascorbic acid in superior amount for 96h of fermented sample, Based on the retention time, the corresponding peaks were detected at 4.919 and 4.831 min.

  8. Three phase partitioning of zingibain, a milk-clotting enzyme from Zingiber officinale Roscoe rhizomes.

    Science.gov (United States)

    Gagaoua, Mohammed; Hoggas, Naouel; Hafid, Kahina

    2015-02-01

    The present work describes for the first time an elegant non-chromatographic method, the three phase partitioning for the purification and recovery of zingibain, a milk-clotting enzyme, from Zingiber officinale rhizomes. Factors affecting partitioning efficiency such as (NH4)2SO4 saturation, crude extract to t-butanol ratio and pH on zingibain partitioning were investigated. Optimal purification parameters were 50% (NH4)2SO4 saturation with 1.0:1.0 ratio of crude extract:t-butanol at pH 7.0, which gave 14.91 purification fold with 215% recovery of zingibain. The enzyme was found to be exclusively partitioned in the aqueous phase. The enzyme showed a prominent single band on SDS-PAGE. It is a monomeric protein of 33.8 kDa and its isoelectric point is 4.38. The enzyme exhibited maximal proteolytic activity at a temperature of 60 °C and pH 7.0. It was found to be stable at 40-65 °C during 2 h. The enzyme was found to be highly stable against numerous metal ions and its activity was enhanced by Ca(2+), K(+) and Na(+). It was completely inhibited by heavy metal ions such as Cu(2+) and Hg(2+) and partially by Cd(+). Zingibain milk-clotting activity (MCA) was found to be highly stable when stored under freezing (-20 °C) for 30 days compared at 4 °C. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. High-intensity focused ultrasound sonothrombolysis: the use of perfluorocarbon droplets to achieve clot lysis at reduced acoustic power.

    Science.gov (United States)

    Pajek, Daniel; Burgess, Alison; Huang, Yuexi; Hynynen, Kullervo

    2014-09-01

    The purpose of this study was to evaluate use of intravascular perfluorocarbon droplets to reduce the sonication power required to achieve clot lysis with high-intensity focused ultrasound. High-intensity focused ultrasound with droplets was initially applied to blood clots in an in vitro flow apparatus, and inertial cavitation thresholds were determined. An embolic model for ischemic stroke was used to illustrate the feasibility of this technique in vivo. Recanalization with intravascular droplets was achieved in vivo at 24 ± 5% of the sonication power without droplets. Recanalization occurred in 71% of rabbits that received 1-ms pulsed sonications during continuous intravascular droplet infusion (p = 0.041 vs controls). Preliminary experiments indicated that damage was confined to the ultrasonic focus, suggesting that tolerable treatments would be possible with a more tightly focused hemispheric array that allows the whole focus to be placed inside of the main arteries in the human brain. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Deep learning for low-dose CT

    Science.gov (United States)

    Chen, Hu; Zhang, Yi; Zhou, Jiliu; Wang, Ge

    2017-09-01

    Given the potential risk of X-ray radiation to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. Currently, the main stream low-dose CT methods include vendor-specific sinogram domain filtration and iterative reconstruction algorithms, but they need to access raw data whose formats are not transparent to most users. Due to the difficulty of modeling the statistical characteristics in the image domain, the existing methods for directly processing reconstructed images cannot eliminate image noise very well while keeping structural details. Inspired by the idea of deep learning, here we combine the autoencoder, deconvolution network, and shortcut connections into the residual encoder-decoder convolutional neural network (RED-CNN) for low-dose CT imaging. After patch-based training, the proposed RED-CNN achieves a competitive performance relative to the-state-of-art methods. Especially, our method has been favorably evaluated in terms of noise suppression and structural preservation.

  11. Fibrin-specific and effective clot lysis requires both plasminogen activators and for them to be in a sequential rather than simultaneous combination.

    Science.gov (United States)

    Pannell, R; Li, S; Gurewich, V

    2017-08-01

    Thrombolysis with tissue plasminogen activator (tPA) has been a disappointment and has now been replaced by an endovascular procedure whenever possible. Nevertheless, thrombolysis remains the only means by which circulation in a thrombosed artery can be restored rapidly. In contrast to tPA monotherapy, endogenous fibrinolysis uses both tPA and urokinase plasminogen activator (uPA), whose native form is a proenzyme, prouPA. This combination is remarkably effective as evidenced by the fibrin degradation product, D-dimer, which is invariably present in plasma. The two activators have complementary mechanisms of plasminogen activation and are synergistic in combination. Since tPA initiates fibrinolysis when released from the vessel wall and prouPA is in the blood, they induce fibrinolysis sequentially. It was postulated that this may be more effective and fibrin-specific. The hypothesis was tested in a model of clot lysis in plasma in which a clot was first exposed to tPA for 5 min, washed and incubated with prouPA. Lysis was compared with that of clots incubated with both activators simultaneously. The sequential combination was almost twice as effective and caused less fibrinogenolysis than the simultaneous combination (p < 0.0001) despite having significantly less tPA, as a result of the wash. A mechanism is described by which this phenomenon can be explained. The findings are believed to have significant therapeutic implications.

  12. Tuberculous adenitis: comparison of CT and MRI findings with histopathological features

    International Nuclear Information System (INIS)

    Backer, A.I. de; Mortele, K.J.; Heuvel, E. van den; Vanschoubroeck, I.J.; Kockx, M.M.; Vyvere, M. van de

    2007-01-01

    Our aim was to investigate the relationship between the various histopathological features and the CT and MRI findings in routinely submitted histopathological specimens for the diagnosis of tuberculous lymphadenopathy. Twelve formalin-fixed, paraffin-embedded tissue blocks from ten patients who were clinically suspected of having tuberculous lymphadenopathy were evaluated. We assessed the presence of histopathological features including granuloma formation, caseous necrosis, and presence of Langhans-type giant cells, calcifications, fibrosis or normal lymphoid tissue. We performed polymerase chain reaction (PCR)-based assay for mycobacterial DNA and Ziehl-Neelsen staining for acid-fast bacilli (AFB). Findings were compared with those of CT and MRI, including signal intensities on unenhanced MR images, lymph node homogeneity, attenuation values on contrast-enhanced CT and enhancement patterns on MRI. Based on CT and MRI findings, four lymph node types could be defined: (1) homogeneous nodes, visible on both pre- and post-contrast images and corresponding histopathologically to granulation tissue without or with minimal caseation necrosis (n = 2); (2) heterogeneous nodes, showing heterogeneous enhancement patterns with central non-enhancing areas and corresponding to minor or moderate intranodal caseation/liquefaction necrosis (n = 3); (3) nodes showing peripheral rim enhancement and corresponding to moderate or extensive intranodal caseation/liquefaction necrosis (n = 5); (4) heterogeneous nodes showing intranodal hyperdensities on CT and hypointense areas on T1- and T2-weighted images and corresponding to fibrosis and calcifications (n = 2). On CT and MRI, the findings reflect different stages of the tuberculous process. Imaging findings depend on the presence and the degree of granuloma formation, caseation/liquefaction necrosis, fibrosis and calcifications. (orig.)

  13. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  14. IMPROVED HEALING OF SMALL-CALIBER POLYTETRAFLUOROETHYLENE PROSTHESES BY INDUCTION OF A CLOT LAYER - A REVIEW OF EXPERIMENTAL STUDIES IN RATS

    NARCIS (Netherlands)

    VANDERLEI, B; STRONCK, JW; WILDEVUUR, CRH

    1991-01-01

    This report reviews our experiments that have been undertaken to test the hypothesis whether the induction of a clot layer on the graft surface of small-caliber polytetrafluoroethylene ( PTFE) prostheses might improve their healing. 1 2 PTFE prostheses with a fibril length of 30-mu-m, PTFE

  15. The clot thickens: an incompletely ligated left  atrial appendage

    Directory of Open Access Journals (Sweden)

    Merrill Thomas

    2018-05-01

    Full Text Available Our patient presented with known mechanical mitral valve endocarditis documented by 2D transesophageal echocardiogram (TOE from a recent hospitalization at an outside facility. On admission to our center, there was no prior knowledge of an incompletely ligated left atrial appendage (LAA according to patient- or family-reported history, review of outside records or the outside facility’s 2D TOE report. A 3D TOE performed at our center to assess her pathology, since a month had passed from her prior hospitalization, revealed a LAA ligation with evidence of communication to the left atrium and with clot present in the appendage. This case report highlights the common finding of incomplete closure of the LAA following surgical ligation, thus making it inadequate for stroke prevention in patients with atrial fibrillation, and that 3D TOE plays a valuable role in assessing the durability of LAA ligation.

  16. In vivo chicken model for peripheral intravascular human fibrin clot detection

    International Nuclear Information System (INIS)

    Hui, K.Y.

    1988-01-01

    A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin

  17. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  18. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  19. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  20. Computed tomography in the diagnosis of sizable formations of the uterine appendages

    International Nuclear Information System (INIS)

    Tarasov, V.V.; Kitaev, V.V.

    1988-01-01

    A total of 40 women were examined using computed tomography (CT). CT results were compared with operative findings. The accuracy of the method was 90%. probable signs of malignancy are an increase in the volume of the uterine appendages, their deformity, structural change, ill-defined borders of a formation with the adjacent organs and tissues, and enlargement of the intrapelvic lymph nodes. Dermoid ovarian cysts could be recognized with utmost accuracy. During CT detection of low density fluid formations with even contours and homogeneous content one should bear in mind a possibility of incapsuled extraorganic fluid accumulations alongside with ovarian cysts

  1. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  2. Analysis of artifact and infrequent physiological uptake in 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Li Tianran; Zhao Chunlei; Qian Gennian; Chen Ziqian; Wang Kaitang; You Xueyu; Zheng Chunyu

    2006-01-01

    Objective: To explore the artifact and infrequent physiological uptake in PET/CT with its imaging and formation features. Methods: The data of PET/CT imaging were retrospectively analyzed and classified based on their cause. Besides, the infrequent physiological uptakes were also analyzed. Results: Artifacts could be classified into natural and technological causes. In natural causes, respiratory movement and high-density matters artifacts were frequently found, whereas in technological cause, the truncation, radioactive leakage and pollution commonly appeared. Infrequent physiological uptakes included uterine endometrium, breast and fat uptakes. Conclusions: The imaging features of artifact in PET can be divided into 'hot' or 'cold' area while infrequent physiological uptakes mainly are 'hot' area. Among the cause of artifact formation, CT-based attenuation corrected physical factor is the commonest. The infrequent physiological uptake somewhat relates to technological error. (authors)

  3. Development and implementation of tPA clot lysis activity assay using ACL TOP™ hemeostasis testing system in QC laboratories

    Directory of Open Access Journals (Sweden)

    Lichun Huang

    2017-12-01

    Full Text Available This report describes the design, development, validation and long-term performance of tPA clot lysis activity assay using Advanced Chemistry Line Total Operational Performance (ACL TOP™ Homeostasis Testing System. The results of the study demonstrated robust and stable performance of the analytical method. The accuracy of the assay, expressed by percent recovery is 98–99%. The intermediate precision and repeatability precision, expressed as Relative Standard Deviation (RSD, was 3% and less than 2% respectively. The validated range is from 70% to 130% of the target potency of 5.8 × 105 IU/mg. The linearity of this range, expressed in correlation coefficient, is 0.997. After the assay is transferred to a QC laboratory, the assay retained high accuracy and precision with a success rate of >99%. Keywords: Potency assay, Clot lysis, Comparability, Automation

  4. The Navy Medical Technology Watch: Hemostatic Dressing Products for the Battlefield

    Science.gov (United States)

    2006-09-09

    composition and ingredients, external bleeding cessation agents all work to help the rapid formation of a thrombus (clot) or other blockage at the...clotting agent Contraindicated for internal bleeding or deep tissue wounds Collagen. Collagen-like natural substances are created from chemically...2003) Experimental (swine) Complex groin injury, arterial, venous QuikClot produced 0% mortality; RDH had a 66% mortality rate. QuikClot

  5. Qualification of a select one-stage activated partial thromboplastin time-based clotting assay and two chromogenic assays for the post-administration monitoring of nonacog beta pegol.

    Science.gov (United States)

    Tiefenbacher, S; Bohra, R; Amiral, J; Bowyer, A; Kitchen, S; Lochu, A; Rosén, S; Ezban, M

    2017-10-01

    Essentials Nonacog beta pegol (N9-GP) is an extended half-life, recombinant human factor IX (FIX). One-stage clotting (OSC) and chromogenic FIX activity assays were assessed for N9-GP recovery. OSC STA ® -Cephascreen ® , ROX FIX and BIOPHEN FIX chromogenic assays were qualified for N9-GP. Other extended half-life factor products should be assessed in a similar way prior to approval. Background Nonacog beta pegol (N9-GP) is an extended half-life, glycoPEGylated recombinant human factor IX that is under development for the prophylaxis and treatment of bleeding episodes in hemophilia B patients. Considerable reagent-dependent variability has been observed when one-stage clotting assays are used to measure the recovery of recombinant FIX products, including N9-GP. Objective To qualify select one-stage clotting and chromogenic FIX activity assays for measuring N9-GP recovery. Methods The accuracy and precision of the one-stage clotting assay (with the STA-Cephascreen activated partial thromboplastin [APTT] reagent) and the ROX Factor IX and BIOPHEN Factor IX chromogenic assays for measuring N9-GP recovery were assessed in N9-GP-spiked hemophilia B plasma samples in a systematic manner at three independent sites, with manufacturer-recommended protocols and/or site-specific assay setups, including different instruments. Results For each of the three FIX activity assays qualified on five different reagent-instrument systems, acceptable intra-assay and interassay accuracy and precision, dilution integrity, reagent robustness and freeze-thaw and short-term sample stabilities were demonstrated. The STA-Cephascreen assay showed a limited reportable range at one of the three qualification sites, and the BIOPHEN Factor IX assay showed suspect low-end sensitivity at one of the three qualification sites. An individual laboratory would account for these limitations by adjusting the assay's reportable range; thus, these findings are not considered to impact the respective

  6. Purification and characterization of a novel milk-clotting metalloproteinase from Paenibacillus spp. BD3526.

    Science.gov (United States)

    Hang, Feng; Wang, Qinbo; Hong, Qing; Liu, Peiyi; Wu, Zhengjun; Liu, Zhenmin; Zhang, Hao; Chen, Wei

    2016-04-01

    In this study, a milk-clotting enzyme (MCE) isolated from Paenibacillus spp. BD3526 was purified and characterized. The MCE was purified 8.9-fold with a 10.11% recovery using ammonium sulfate precipitation and anion-exchange chromatography and the specific milk-clotting activity (MCA) reached 6791.73 SU/mg. The enzyme was characterized as a 35kDa metalloproteinase, and the zymogen of which was encoded by a 1671 bp gene named zinc metalloproteinase precursor (zmp) with a predicted molecular weight of 59.6 kDa. The optimal temperature for MCA and proteolytic activity (PA) was 65°C and 60°C, respectively. The enzyme was stable over a pH range of 5.0-9.0 and at temperatures below 50°C. The MCA was completely inactivated when the enzyme was heated at 60°C for 30 min, and the PA was totally inactivated for 20 and 10 min when the enzyme was heated at 55°C and 60°C, respectively. The BD3526 enzyme was preferentially active towards κ-casein (κ-CN) and β-casein (β-CN), as determined by sodium dodecyl sulfate-polyacrylamide gels (SDS-PAGE), whereas the hydrolysis of αs-casein (αs-CN) was slow and comparable to that caused by chymosin and asparatic acid proteinase from Rhizomucor miehei. The cleavage site of the metalloproteinase in κ-CN was located at the Met106-Ala107 bond, as determined by mass spectrometry analysis. Copyright © 2016. Published by Elsevier B.V.

  7. [Comparison between Endoscopic Therapy and Medical Therapy in Peptic Ulcer Patients with Adherent Clot: A Multicenter Prospective Observational Cohort Study].

    Science.gov (United States)

    Kim, Si Hye; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young; Lee, Dong Wook; Jeon, Seong Woo; Park, Kyung Sik; Lee, Si Hyung; Park, Jeong Bae; Ha, Chang Yoon; Park, Youn Sun

    2015-08-01

    The optimal management of bleeding peptic ulcer with adherent clot remains controversial. The purpose of this study was to compare clinical outcome between endoscopic therapy and medical therapy. We also evaluated the risk factors of rebleeding in Forrest type IIB peptic ulcer. Upper gastrointestinal (UGI) bleeding registry data from 8 hospitals in Korea between February 2011 and December 2013 were reviewed and categorized according to the Forrest classification. Patients with acute UGI bleeding from peptic ulcer with adherent clots were enrolled. Among a total of 1,101 patients diagnosed with peptic ulcer bleeding, 126 bleedings (11.4%) were classified as Forrest type IIB. Of the 126 patients with adherent clots, 84 (66.7%) received endoscopic therapy and 42 (33.3%) were managed with medical therapy alone. The baseline characteristics of patients in two groups were similar except for higher Glasgow Blatchford Score and pre-endoscopic Rockall score in medical therapy group. Bleeding related mortality (1.2% vs.10%; p=0.018) and all cause mortality (3.7% vs. 20.0%; p=0.005) were significantly lower in the endoscopic therapy group. However, there was no difference between endoscopic therapy and medical therapy regarding rebleeding (7.1% vs. 9.5%; p=0.641). In multivariate analysis, independent risk factors of rebleeding were previous medication with aspirin and/or NSAID (OR, 13.1; p=0.025). In patients with Forrest type IIB peptic ulcer bleeding, endoscopic therapy was associated with a significant reduction in bleeding related mortality and all cause mortality compared with medical therapy alone. Important risk factor of rebleeding was use of aspirin and/or NSAID.

  8. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  9. Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.

    Science.gov (United States)

    Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F

    2013-09-01

    The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.

  10. Reducing dose in paediatric CT: a preliminary study of radiographers' knowledge

    International Nuclear Information System (INIS)

    Heagney, J.; Lewis, S.; Chaffey, C.; Howlett, G.; Moran, A.; McLean, D.

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs. Copyright (2003) Australian Institute of Radiography

  11. Reducing dose in paediatric CT: a preliminary study of radiographers' Knowledge

    International Nuclear Information System (INIS)

    Heagney, Jillian; Lewis, Sarah; Chaffey, Clare; Howlett, Genevieve; Moran, Alexander; McLean, Donald

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs Copyright (2003) Australian Institute of Radiography

  12. The use of QuikClot combat gauze in cervical and vaginal hemorrhage

    Directory of Open Access Journals (Sweden)

    Nicole Vilardo

    2017-08-01

    Full Text Available QuikClot combat gauze is a synthetic hemostatic dressing used for hemorrhage control. There is a paucity of data describing the clinical use and hemostatic results of combat gauze in the obstetric and gynecologic setting. This case series demonstrates the use of combat gauze as an effective hemostatic agent when used as vaginal packing in cervical and vaginal hemorrhage. Hemostasis was achieved rapidly in all cases and further interventions were avoided. The combat gauze remained in place for a mean time of 15 h with no adverse side effects observed. The use of combat gauze as vaginal packing may provide an alternative option in the treatment of cervical and vaginal hemorrhage when other traditional conservative and surgical interventions fail or are unavailable.

  13. In vitro evaluation of the effect of haemodilution with dextran 40 on coagulation profile as measured by thromboelastometry and multiple electrode aggregometry.

    Science.gov (United States)

    Kam, Pca; Liou, Jpc; Yang, Kxf

    2017-09-01

    We evaluated the effects of haemodilution with either dextran 40 or 0.9% normal saline on coagulation in vitro using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany) and multiple electrode aggregometry (Multiplate® Platelet Function Analyser, Dynabyte, Munich, Germany). Venous blood samples obtained from 20 healthy volunteers were diluted in vitro with dextran 40 or normal saline by 5%, 10% and 15%. Fibrinogen concentration, ROTEM-EXTEM® (screening test for the extrinsic coagulation pathway), FIBTEM® (an EXTEM-based assay of the fibrin component of clot) parameters including coagulation time, clot formation time, alpha angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each level of haemodilution. Dextran 40 at 15% haemodilution significantly prolonged coagulation time, clot formation time and significantly decreased the alpha angle and maximal clot firmness (EXTEM amplitude at five minutes [A5] and ten minutes [A10]) compared with normal saline. The FIBTEM assay (maximal clot firmness and FIBTEM A5 and A10) showed a marked decrease in maximal clot firmness at all dilutions suggesting impaired fibrinogen activity and a risk of bleeding. Multiple electrode aggregometry did not demonstrate any platelet dysfunction. Haemodilution with dextran 40 causes significant impairment in clot formation and strength compared to saline haemodilution and undiluted blood. At the levels of in vitro haemodilution designed to reflect the clinical use of dextran infusions, no significant fibrinolysis or platelet inhibition was observed.

  14. In vitro Ca(2+)-dependent maturation of milk-clotting recombinant Epr: minor extracellular protease: from Bacillus licheniformis.

    Science.gov (United States)

    Ageitos, José Manuel; Vallejo, Juan Andrés; Serrat, Manuel; Sánchez-Pérez, Angeles; Villa, Tomás G

    2013-06-01

    The minor extracellular protease (Epr) is secreted into the culture medium during Bacillus licheniformis, strain USC13, stationary phase of growth. Whereas, B. subtilis Epr has been reported to be involved in swarming; the B. licheniformis protease is also involved in milk-clotting as shown by the curd forming ability of culture broths expressing this protein. The objectives of this study are the characterization of recombinant B. licheniformis Epr (minor extracellular protease) and the determination of its calcium-dependent activation process. In this work, we have cloned and expressed B. licheniformis Epr in Escherichia coli. We were also able to construct a tridimensional model for Epr based on its homology to Thermococcus kodakarensis pro-tk-subtilisin 2e1p, fervidolysin from Fervidobacterium pennivorans 1rv6, and B. lentus 1GCI subtilisin. Recombinant Epr was accumulated into inclusion bodies; after protein renaturation, Epr undergoes an in vitro calcium-dependent activation, similar to that described for tk protease. The recombinant Epr is capable of producing milk curds with the same clotting activity previously described for the native B. licheniformis Epr enzyme although further rheological and industrial studies should be carried out to confirm its real applicability. This work represents for the first time that Epr may be successfully expressed in a non-bacilli microorganism.

  15. Venom Concentrations and Clotting Factor Levels in a Prospective Cohort of Russell's Viper Bites with Coagulopathy.

    Directory of Open Access Journals (Sweden)

    Geoffrey K Isbister

    Full Text Available Russell's viper envenoming is a major problem in South Asia and causes venom induced consumption coagulopathy. This study aimed to investigate the kinetics and dynamics of venom and clotting function in Russell's viper envenoming.In a prospective cohort of 146 patients with Russell's viper envenoming, we measured venom concentrations, international normalised ratio [INR], prothrombin time (PT, activated partial thromboplastin time (aPTT, coagulation factors I, II, V, VII, VIII, IX and X, and von Willebrand factor antigen. The median age was 39 y (16-82 y and 111 were male. The median peak INR was 6.8 (interquartile range [IQR]: 3.7 to >13, associated with low fibrinogen [median,3 at 6 h post-antivenom but had reduced to <2, by 24 h. The aPTT had also returned to close to normal (<50 sec at 24 h. Factor VII, VIII and IX levels were unusually high pre-antivenom, median peak concentrations of 393%, 307% and 468% respectively. Pre-antivenom venom concentrations and the INR (r = 0.20, p = 0.02 and aPTT (r = 0.19, p = 0.03 were correlated (non-parametric Spearman analysis.Russell's viper coagulopathy results in prolonged aPTT, INR, low fibrinogen, factors V, VIII and X which recover over 48 h. Severity of clotting abnormalities was associated with venom concentrations.

  16. Hematuria and clot retention after transvaginal oocyte aspiration: a case report.

    Science.gov (United States)

    Modder, Joshua; Kettel, L Michael; Sakamoto, Kyoko

    2006-09-01

    To report a case of bladder injury with hematuria and urinary retention after transvaginal oocyte aspiration. Case report. Emergency room in a university medical center. A 28-year-old woman presented with urinary retention and suprapubic pain 8 hours after oocyte aspiration. Foley catheter, intravenous fluid bolus, bladder irrigation, and computed tomography with postvoid films that showed a blood clot in the bladder. Patient was discharged home with antibiotics and catheter in place. Clinical follow-up. Patient passed voiding trial 4 days later and was artificially inseminated. No further hematuria or voiding problems were reported, and she had a successful pregnancy. Patients who elect to undergo oocyte aspiration should be warned about the possibility of bladder injury because of the close proximity of the ovaries to the bladder, and physicians should have an appropriate treatment plan.

  17. CT and clinical study for intratumoral gas formation in post transarterial embolization of hepatoma and renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Katsuragi, M; Matsuo, N; Yoshikawa, K [Nara Medical Univ., Kashihara (Japan)

    1982-09-01

    Thirty-two patients with hepatocellular carcinoma and six patients with renal cell carcinoma for whom the arterial embolization therapy was performed were studied by CT and clinical follow-up for investigating intratumoral gas detected on CT in post-embolization cases. The intratumoral air was found by CT in seven patients with hepatocellular carcinoma and four patients with renal cell carcinoma. The air was composed of a collection of multiple small round gas bubbles in the embolized tumor except in one case where it formed a serpiginous pattern. There was no hematologic nor clinical evidence of liver abscess in all the cases. It was possible to distinguish gas from abscess or fat by a combination of CT and clinical findings.

  18. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  19. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon

    1988-01-01

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult cases.

  20. Effects of gastric bypass followed by a randomized study of physical training on markers of coagulation activation, fibrin clot properties, and fibrinolysis

    DEFF Research Database (Denmark)

    Stolberg, Charlotte Røn; Mundbjerg, Lene Hymøller; Funch-Jensen, Peter

    2018-01-01

    disease risk markers within coagulation activation, fibrin clot properties, and fibrinolysis. Setting: Bariatric center, Hospital of Southwest Jutland, Denmark. Methods: Sixty obese patients underwent RYGB and 6 months after RYGB were randomized to 26 weeks of physical training or a control group...

  1. The role of CT in patient management after liver transplantation

    International Nuclear Information System (INIS)

    Galanski, M.; Drewes, J.; Gubernatis, G.; Chavan, A.; Prokop, M.

    1992-01-01

    To evaluate the value of CT in clarifying the nature of complications after orthopedic liver transplantation, we restrospectively evaluated the files of 88 patients in light of the clinical course and all available diagnostic data. The liver tranplantations were performed in the years 1986 and 1987. As a rule, the examinations comprised of continuous 8 mm-thick CT sections of the abdomen. In the majority of the cases, contrast medium was administered for opacification of the bowel loops, either orally or through a tube. Bowel movement was reduced by intravenous (i.v.) Buscopan. In our series an increase in the periportal hypodensities was found to be an unfavourable prognostic sign. A high percentage of patients with this CT finding subsequently progressed to graft failure due to reasons other than graft rejection. Hence in the final analysis, the CT sign is non-specific and does not permit the definitive diagnosis of graft rejection. Nevertheless, CT is important for excluding conditions that demand surgical intervention, in particular abscess formation. (orig./MG)

  2. Using a WebCT to Develop a Research Skills Module

    OpenAIRE

    Bellew Martin, Kelli; Lee, Jennifer

    2003-01-01

    At the start of every academic year, the University of Calgary Library welcomes 1,000 first-year biology students to basic library research skills sessions. These sessions are traditionally taught in lecture format with a PowerPoint presentation and students following along on computers. As part of a pilot project in the Fall of 2002, 200 first-year biology students received the session via WebCT. WebCT is the web-based course management system utilized by the University of Calgary1; it d...

  3. Total artificial heart in the pediatric patient with biventricular heart failure.

    Science.gov (United States)

    Park, S S; Sanders, D B; Smith, B P; Ryan, J; Plasencia, J; Osborn, M B; Wellnitz, C M; Southard, R N; Pierce, C N; Arabia, F A; Lane, J; Frakes, D; Velez, D A; Pophal, S G; Nigro, J J

    2014-01-01

    Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would

  4. Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis

    OpenAIRE

    Hoffmann, Andrew; Gill, Harjit

    2012-01-01

    Abstract Background Low Frequency Vibro-Percussion (LFVP) assists clearance of thrombi in catheter systems and when applied to the heart and timed to diastole is known to enhance coronary flow. However LFVP on a clotted coronary like vessel given engagement over a chest wall sized barrier (to resemble non-invasive heart attack therapy) requires study. Methods One hour old clots (n=16) were dispensed within a flexible segment of Soft-Flo catheter (4 mm lumen), weighted, interfaced with Heparin...

  5. The role of the lysyl binding site of tissue-type plasminogen activator in the interaction with a forming fibrin clot

    NARCIS (Netherlands)

    Bakker, A.H.F.; Weening-Verhoeff, E.J.D.; Verheijen, J.H.

    1995-01-01

    To describe the role of the lysyl binding site in the interaction of tissue-type plasminogen activator (t-PA, FGK1K2P) with a forming fibrin clot, we performed binding experiments with domain deletion mutants GK1K2P, K2P, and the corresponding point mutants lacking the lysyl binding site in the

  6. In vivo microCT imaging of rodent cerebral vasculature

    International Nuclear Information System (INIS)

    Seo, Youngho; Hasegawa, Bruce H; Hashimoto, Tomoki; Nuki, Yoshitsugu

    2008-01-01

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I tube x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml -1 at 1.2 ml min -1 ) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (∼85 μm) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels

  7. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  8. Rediscovering the wound hematoma as a site of hemostasis during major arterial hemorrhage.

    Science.gov (United States)

    White, N J; Mehic, E; Wang, X; Chien, D; Lim, E; St John, A E; Stern, S A; Mourad, P D; Rieger, M; Fries, D; Martinowitz, U

    2015-12-01

    Treatments for major internal bleeding after injury include permissive hypotension to decrease the rate of blood loss, intravenous infusion of plasma or clotting factors to improve clot formation, and rapid surgical hemostasis or arterial embolization to control bleeding vessels. Yet, little is known regarding major internal arterial hemostasis, or how these commonly used treatments might influence hemostasis. (i) To use a swine model of femoral artery bleeding to understand the perivascular hemostatic response to contained arterial hemorrhage. (ii) To directly confirm the association between hemodynamics and bleeding velocity. (iii) To observe the feasibility of delivering an activated clotting factor directly to internal sites of bleeding using a simplified angiographic approach. Ultrasound was used to measure bleeding velocity and in vivo clot formation by elastography in a swine model of contained femoral artery bleeding with fluid resuscitation. A swine model of internal pelvic and axillary artery hemorrhage was also used to demonstrate the feasibility of local delivery of an activated clotting factor. In this model, clots formed slowly within the peri-wound hematoma, but eventually contained the bleeding. Central hemodynamics correlated positively with bleeding velocity. Infusion of recombinant human activated factor VII into the injured artery near the site of major internal hemorrhage in the pelvis and axillae was feasible. We rediscovered that clot formation within the peri-wound hematoma is an integral component of hemostasis and a feasible target for the treatment of major internal bleeding using activated clotting factors delivered using a simplified angiographic approach. © 2015 International Society on Thrombosis and Haemostasis.

  9. A preliminary study to detect CT radiation doses by using the γH2AX focus formation assay

    International Nuclear Information System (INIS)

    Zhang Bo; Gong Jianping; Zhang Wei; Yu Zeyang; Zhou Liying; Zhang Hong; Fu Jinxiang

    2010-01-01

    To prospectively determine if γH2AX (phosphorylated form of H2AX histone variant)-based visualization and quantification of DNA damage induced in peripheral blood mononuclear cells (PBMCs) can be used to estimate the radiation dose received after multi-detector computed tomography (CT) by the in vitro study, comprehend the correlation between the dose and the induced γH2AX foci, and explore its prospect. The result showed that, DNA damage first presented as γH2AX foci after CT, which can be detected by fluorescence microscope. The γH2AX focus yields linearly depend on the radiation dose after CT. γH2AX focus yield in blood cells may be a useful quantitative biomarker of human radiation exposure by CT scans. (authors)

  10. CT imaging of complications of catheter ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Shroff, G.S.; Guirguis, M.S.; Ferguson, E.C.; Oldham, S.A.A.; Kantharia, B.K.

    2014-01-01

    The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation

  11. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  12. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  13. Pitfalls in multidetector row CT colonography

    International Nuclear Information System (INIS)

    Stoyneva, V.

    2009-01-01

    Full text:MDCT colonography is a reliable method for detection and identification of type of the colon lesions. At every step of the examination an error could be made and that would be lead to an incorrect diagnosis. Problems and pitfalls can be overcome with various useful techniques. The relatively clean and dry colon after careful preparation, allows avoiding problems of residual fluid and faeces. The knowledge about the structure and thickness characteristics of lesions of the colon and artefacts can to be useful in distinction of the polypoidal lesions from normal findings. The aim of this lecture is to describe common and less common pitfalls in CT colonography and to clarify features and CT criteria to distinction of organic formations from pseudo lesions. Inadequate preparation of the patient, weaknesses into the protocol, gaps and errors in interpretation are responsible for false positive and false negative results. The training which reduces the residual solids and liquid, marking, protocols elaboration and CAD allows achieving higher sensitivity and specificity. The 2D and 3D application techniques and solid knowledge about CT characteristic of the colon organic findings and pseudo lesions will reduce the rate of false positive results

  14. Quality of Clotting Factor Activity in Fresh Frozen Plasma at Thaw with a Microwave System and after Storage at 4 degrees C for 48 Hours.

    Science.gov (United States)

    Kuta, Piotr; Hauck-Dlimi, Barbara; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold

    2016-01-01

    Uncontrolled hemorrhage in polytrauma patients usually results in rapid need of blood products. Despite the shorter thawing times of microwave devices for heating fresh frozen plasma (FFP), their use has remained controversial, and just a few laboratory analyses have been published on this topic. The aim of this study was to analyse the quality of clotting factors immediately after thawing FFP with a microwave device and after 48-hour post thaw storage at 4 degrees C. 24 FFP units of all four ABO blood groups (six of each blood group) were thawed with a Transfusio-therm 2000 and later stored at 4 degrees C for 48 hours. Samples were drawn aseptically and investigated on various clotting factors and protein proteases (fibrinogen, antithrombin, FII, FV, FVII, FVIII, FIX, FX, FXI, FXIII, vWF antigen and activity, protein S, and protein C) using standard coagulation and chromogenic assays immediately after thawing and again after a 48-hour storage period at 4 degrees C. All units were tested for both anaerobic and aerobic microbial contamination using standard operating procedures immediately after thawing. After thawing, all coagulation factors and protein protease activities were within normal ranges. Blood group O individuals had approximately 25% lower plasma levels of vWF antigen and activity. After a 48-hour storage period at 4 degrees C, FVIII and FIX activities declined significantly in all blood groups, whereas the remaining clotting factors remained comparably stable. Immediately after rapid thawing using a microwave system, all FFP units contained adequate coagulation factor activities to maintain hemostatic activity at the time of product thaw. The post thaw refrigerated storage caused an anticipated decrease in factor VIII and IX activities, but retained normal coagulation factor levels of many plasma proteins. Therefore we conclude that the Transfusio-therm 2000 has no clinically significant influence on the activity of clotting factors and plasma

  15. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  16. Impact in the facilities design and the personnel formation of the hybrid equipment s: PET-CT

    International Nuclear Information System (INIS)

    Hernandez, R.; Soler, K.; Alonso, I.

    2014-08-01

    The Positron Emission Tomography-Computed Tomography (PET-CT), in the last years has demonstrated to be an image technique very effective for the diagnosis and the treatments continuation in different medical applications, because provides a valuable clinical information for the patient handling. The PET-CT is a technology used in the nuclear medicine for diagnostic, because integrates two different image techniques in an only device and in a single exam or study combine the results of both techniques. Also, is a hybrid tomograph that provides in a single image the biochemical information of a technique and the anatomical information of the other, what means that unifies the spatial resolution of a technique and the contrast resolution of the other, allowing this way to obtain a more precise and detailed diagnostic information, opening new opportunities in diagnostic, Radiotherapy planning and treatments continuation to the patients, being generated new links among the different radiological medical specialties. In nuclear medicine facilities with PET-CT, the radiological protection presents particular characteristics, due to the photons coexistence of 511 keV (generated by the annihilation of the emitted positrons from the different exposure sources) together to the X-rays emitted by the CT, what impacts in a direct way in those design requirements of the areas. On the other hand, this combination of the two image techniques imposes additional requirements to the learning and training of personnel, not considered until the present time. In this article are exposed the general principles that should be considered in the design of a Nuclear Medicine Area with PET-CT, and the existent problems related to the learning and training of personnel to assume this new technology are also approached. (Author)

  17. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  18. The value of CT in detecting pathologic bowel perforation

    International Nuclear Information System (INIS)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi

    1997-01-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for 1) diagnosis of bowel perforation, 2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and 3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20

  19. Potential of quixaba (Sideroxylon obtusifolium latex as a milk-clotting agent

    Directory of Open Access Journals (Sweden)

    Anna Carolina da Silva

    2013-09-01

    Full Text Available There are several obstacles to the use of chymosin in cheese production. Consequently, plant proteases have been studied as possible rennet substitutes, but most of these enzymes are unsuitable for the manufacture of cheese. The aim of this study was to evaluate the potential of latex from Sideroxylon obtusifolium as a source of milk-clotting proteases and to partially characterize the enzyme. The enzyme extract showed high protease and coagulant activities, with an optimal pH of 8.0 and temperature of 55 °C. The enzyme was stable in wide ranges of temperature and pH. Its activity was not affected by any metal ions tested; but was inhibited by phenylmethanesulfonyl fluoride and pepstatin. For the coagulant activity, the optimal concentration of CaCl2 was 10 µmol L- 1. Polyacrylamide gel electrophoresis showed four bands, with molecular weights between 17 and 64 kDa. These results indicate that the enzyme can be applied to the cheese industry.

  20. A comparison of micro-CT, microradiography and histomorphometry in bone research

    NARCIS (Netherlands)

    Gielkens, Pepijn F. M.; Schortinghuis, Jurjen; de Jong, Johan R.; Huysmans, Marie Charlotte D. N. J. M.; van Leeuwen, M. Barbara M.; Raghoebar, Gerry M.; Bos, Ruud R. M.; Stegenga, Boudewijn

    Objective: Intraobserver reliability and agreement were determined for microradiography (MR), micro-computed tomography (mu CT) and histomorphometry (HM). These three modalities were compared for quantitative measurements of bone formation and graft modelling in rat mandibular defects and grafts.

  1. Clinical features and CT scan findings of supratentorial ependymomas and ependymoblastomas

    International Nuclear Information System (INIS)

    Hanakita, Junya; Handa, Hajime

    1984-01-01

    The clinical courses and CT scan findings of 12 cases of supratentorial ependymoma and ependymoblastoma were reviewed. The age of the patient of ependymoma ranged from 3 years to 34 years, with an average age of 16 years. The follow-up time ranged from 2 months to 9 years and 10 months. All of the six patients are still alive. The age of the patients of ependymoblastoma ranged from 7 months to 34 years, with an average age of 17 years. During the follow-up period from 2 weeks to 6 years and 4 months, four patients died. Supratentorial ependymomas and ependymoblastomas show the following characteristic features of CT scans: 1. Calcification: The incidence of calcification was 50% in ependymoma-group, and 100% in ependymoblastoma-group. 2. Cyst formation, ring-enhancement: The cyst formation was noticed in both groups. In ependymoma-group a smooth ring-enhancement pattern and the strongly enhanced mural nodule-like contour were found, but in ependymoblastoma-group, the cyst wall was enhanced in irregular shape. 3. Perifocal edema and mass effect: Considerable mass effect was noticed in both groups. Perifocal edema was slight in many cases of ependymoma-group, but mostly prominent in ependymoblastoma-group. 4. CT scan findings of recurrent tumor: In ependymoma-group, recurrent tumor showed the same characteristics of CT scan as the initial ones. In ependymoblastoma-group, cystic portion decreased in size and irregular shaped solid portion increased in recurrence. (author)

  2. MRI and CT features of hyperplastic callus in osteogenesis imperfecta tarda

    International Nuclear Information System (INIS)

    Dobrocky, I.; Seidl, G.; Grill, F.

    1999-01-01

    We describe the MRI and CT findings of hyperplastic callus formation simulating a tumour of pelvis in patient with osteogenesis imperfecta tarda. Possible differential diagnoses and the impact of different imaging techniques on the correct diagnosis are discussed. (orig.)

  3. Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation

    International Nuclear Information System (INIS)

    Fukumori, Neuza Taeko Okasaki

    2008-01-01

    Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDA's LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the 131 I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the lyophilized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL -1 (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL -1 , to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products 131 I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and

  4. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  5. The Effect of Radioactive Lantern Mantle Powder and Bentonite-Zeoloite Minerals on the Volume of Blood Loss, Bleeding and Clotting Time

    Directory of Open Access Journals (Sweden)

    M Atefi

    2009-04-01

    Full Text Available ABSTRACT Introduction & Objective: Over the past decade the US army has widely studied new technologies for stopping sever hemorrhages and has introduced an effective Zeolite based hemostatic agent. On the other hand, Mortazavi and his colleagues previously reported the bio-stimulatory effects of the topical application of radioactive lantern mantle powder on wound healing. Their subsequent studies showed significant changes in some histological parameters concerning healing. In this light, here the bio-stimulatory effect of burned radioactive lantern mantles powder as well as two minerals bentonite and zeolite are presented. Materials & Methods: This experimental study was conducted in the center for radiological studies, Shiraz University of Medical Sciences in 2008. Fifty male Wistar rats were divided randomly into 5 groups of 10 animals each. Following anesthesia, animals’ tails were cut at a thickness of 5 mm by using a surgical scissor. No intervention was made on the animals of the 1st group. The 2nd to 4th group received topical non-radioactive lantern mantle powder, radioactive lantern mantle powder, Bentonite mineral or a mixture of Bentonite-Zeoliteat minerals respectively. After treatment with above mentioned agents, the volume of blood loss was measured using a scaled test-tube. The bleeding time and clotting time were also measured using a chronometer. SPSS software was used for statistical analysis. ANOVA was used for comparing the means of each parameter in the 5 groups. Results: The the volume of blood loss, bleeding and clotting times in control animals were 4.39±1.92 cc, 112.10±39.60 sec and 94.9±54.26 sec, respectively. In the 5th group in which the animals were treated with a mixture of Bentonite-Zeoliteat minerals, the volume of blood loss, bleeding and clotting times were 1.31±0.60 cc, 34.50±4.65 sec and 24.2±4.61 sec, respectively. Conclusion: This is the 1st investigation that studied the alterations of bleeding

  6. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  7. Effect of the association between citric acid and EDTA on root surface etching.

    Science.gov (United States)

    Manzolli Leite, Fabio Renato; Nascimento, Gustavo Giacomelli; Manzolli Leite, Elza Regina; Leite, Amauri Antiquera; Cezar Sampaio, Josá Eduardo

    2013-09-01

    This study aims to compare the clot stabilization on root surfaces conditioned with citric acid and ethylenediamine-tetraacetic acid (EDTA). Scaled root samples (n = 100) were set in fve groups: group I-control group (saline solution); group II (24% EDTA); group III (25% citric acid); group IV (EDTA + citric acid); group V (citric acid + EDTA). Fifty samples were assessed using the root surface modifcation index (RSMI). The other 50 received a blood drop after conditioning. Clot formation was assessed using blood elements adhesion index (BEAI). A blind examiner evaluated photomicrographs. Statistical analysis considered p EDTA employment before citric acid (group-IV) reduced clot formation in comparison to citric acid use alone (group-III). Root conditioning with citric acid alone and before EDTA had the best results for smear layer removal and clot stabilization. EDTA inhibited clot stabilization on root surface and must have a residual activity once it has diminished clot adhesion to root even after citric acid conditioning. Thus, EDTA can be used to neutralize citric acid effects on periodontal cells without affecting clot stabilization. Clinical signifcance: To demonstrate that citric acid use on root surfaces previously affected by periodontal disease may favor clot stabilization and may have a benefcial effect on surgical outcomes. Also, EDTA can be used to neutralize citric acid effects on periodontal cells.

  8. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  9. Efficient digitalization method for dental restorations using micro-CT data.

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-15

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  10. Efficient digitalization method for dental restorations using micro-CT data

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-01

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  11. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  12. [Prehospital use of haemostatic dressing QuikClot ACS+™ for hemorrhage control of a perineal trauma].

    Science.gov (United States)

    Travers, S; Dubourg, O; Ribeiro Parenti, L; Lefort, H; Albarello, S; Domanski, L

    2012-12-01

    First responders are sometimes confronted with external uncontrolled haemorrhage despite compression, bandages, and tourniquets. Several topical haemostatic agents were developed to try to face these situations. Their application was mainly described and studied in military environment. We report the case of a worker victim of an accident of construction site with hemorrhagic perineal trauma for whom the use of a haemostatic bandage QuikClot ACS+™ (Z-Medica) seemed to us particularly useful in prehospital setting. Copyright © 2012 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  13. The value of CT in detecting pathologic bowel perforation

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi [Keimyung Univ. School of Medicine, Taegu (Korea, Republic of)

    1997-10-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for (1) diagnosis of bowel perforation, (2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and (3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20.

  14. Process of evolution to chronic subdural hematoma, (1); A study with MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Ryungchan; Takeuchi, Fumihiko; Yokoyama, Masato; Sasaki, Takashi (Kanazawa Medical Univ. Uchinada (Japan)); Mun, Jhongbu; Ohi, Masayoshi

    1989-10-01

    The process of evolution to chronic subdural hematoma (CSH) was discussed on the basis of MRI and CT findings. The materials were 22 sides of 15 cases in which CSH had been diagnosed by means of MRI, CT, and/or surgery. These cases were followed by CT with/without MRI after the initial head injury. Various findings were shown in the subdural space, such as subdural hygroma (40%), acute subdural hematoma (25%), normal state (20%), and traumatic subarachnoid hemorrhage (15%). Regardless of the conditions of the subdural space after the head injury, however, CSH was finally present in all cases after the formation of subdural hygroma and its enlargement. The duration of the formation of hygroma after head injury ranged from 0 to 12 days (mean: 2.7 days), and its final confirmation ranged from 11 to 61 days (mean: 33.4 days). The period from the final confirmation of hygroma to the first recognition of CSH was between 8 and 36 days (mean: 17.7 days), while the period from head injury to the formation of CSH was between 27 and 75 days (mean: 51.1 days). The process of evolution to CSH may be thought to be as follows: A normal subdural space changes into a subdural hygroma by the tearing of the arachnoid membrane due to head injury. Capsule formation follows the process lasting for more than three weeks. CSH develops in consequence of bleeding from the outer membrane. (author).

  15. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  16. Laboratory heterogeneity of the lupus anticoagulant: a multicentre study using different clotting assays on a panel of 78 samples. Hemostasis Committee of the "Société Française de Biologie Clinique".

    Science.gov (United States)

    1992-05-15

    The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.

  17. The mechanism of cerebral aneurysmal formation

    International Nuclear Information System (INIS)

    Yokoi, Toshihiro; Nozaki, Kazuhiko

    2010-01-01

    Cerebral aneurysm is a disease of poor prognosis and MR- and CT-angiographies are used for its diagnosis and in the preventive therapy of its rupture. Here discussed are formation and growth leading to rupture of the lesion for its advanced diagnosis and prevention of rupturing. Beginning from findings in animal experimentation in mice, rats and monkeys, discussed are pathology of the aneurysm, genes related with its formation, molecular biological approaches concerning apoptosis and NF-kB/TNF-α related inflammatory reactions, participation of sex hormone, clinical hemodynamic analyses based on 3D data from CT and MRI findings, and clinical studies. Authors consider that local hemodynamic stress loading is possibly related to cerebral aneurysm formation as it is yielded at the loading part of the vessel in human and in animal models. The aneurysm is possibly a result of remodeling disturbance by the load and subsequent excessive involution of the artery. In the process, probably included are the inflammation, apoptosis, degradation of extracellular matrix and functional impairment of endotherial cells. Future elucidation of molecular mechanisms underlying the aneurismal growth and rupture will bring about the improved treatment to prevent the disease by stabilizing the aneurismal wall. (T.T.)

  18. PET/CT Atlas on Quality Control and Image Artefacts

    International Nuclear Information System (INIS)

    2014-01-01

    Combined positron emission tomography (PET)/computed tomography (CT) imaging has become a routine procedure in diagnostic radiology and nuclear medicine. The clinical review of both PET and PET/CT images requires a thorough understanding of the basics of image formation as well as an appreciation of variations of inter-patient and intra-patient image appearance. Such variations may be caused by variations in tracer accumulation and metabolism, and, perhaps more importantly, by image artefacts related to methodological pitfalls of the two modalities. This atlas on quality control (QC) and PET/CT artefacts provides guidance on typical image distortions in clinical PET/CT usage scenarios. A number of cases are presented to provide nuclear medicine and radiology professionals with an assortment of examples of possible image distortions and errors in order to support the correct interpretation of images. About 70 typical PET and PET/CT cases, comprised of image sets and cases, have been collected in this book, and all have been catalogued and have explanations as to the causes of and solutions to each individual image problem. This atlas is intended to be used as a guide on how to take proper QC measures, on performing situation and problem analysis, and on problem prevention. This book will be especially useful to medical physicists, physicians, technologists and service engineers in the clinical field

  19. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  20. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  1. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  2. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  3. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  4. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  5. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  6. Observation of microscopic bone structure during bone formation. Application of micro-computed tomography for evaluation of bone quality

    International Nuclear Information System (INIS)

    Ueno, Takaaki; Yamamoto, Hiromitsu; Mizukawa, Nobuyoshi; Mishima, Katsuaki; Takagi, Shin; Sugahara, Toshio

    1998-01-01

    Bone formation in the autogenous periosteum of the tibia grafted to the floor of the mouth to bridge the mandible was studied by micro-CT to assess its efficacy in evaluating bone formation in rabbits. On soft radiographs, bone formation was observed from both ends of the periosteum on day 14. The bone increased in width and extended medially; contact was made in the center on day 28. The time course of the development of bone trabeculae was well demonstrated three-dimensionally on micro-CT. Indices of bone quality such as Tb-Th, Tb.N, and BV, which reflect the growth of trabeculae, increased gradually from days 14 to 21 and more rapidly from days 21 to 28, whereas Tb. S decreased gradually after grafting. The results suggest that micro-CT is useful in evaluating bone formation three-dimensionally. (author)

  7. Effect of PDGF-BB and beta-tricalcium phosphate (β-TCP) on bone formation around dental implants: a pilot study in sheep.

    Science.gov (United States)

    Choo, Tina; Marino, Victor; Bartold, P Mark

    2013-02-01

    The aim of this investigation was to examine the effect of a combination of purified recombinant human platelet-derived growth factor (rhPDGF-BB) mixed with a synthetic beta-tricalcium phosphate (β-TCP) on bone healing around dental implants with critical size circumferential defects. Three critical size circumferential defects were prepared in the ilium of six sheep. Three dental implants were placed into the centre of each defect and the 3.25 mm circumferential gap was filled with (a) blood clot alone; (b) β-TCP; (c) rhPDGF-BB (0.3 mg/ml) with β-TCP. All the defects in each group were covered with a Bio-Gide(®) resorbable barrier membrane. The sheep were sacrificed at 2 and 4 weeks and histological and histomorphometric analyses were performed to determine the percentage of new mineralized bone formation and residual β-TCP graft particles in the defects. Defects filled with rhPDGF-BB/β-TCP showed the highest rate of bone formation after 2 and 4 weeks with limited degradation of the β-TCP particles over 4 weeks. Defects filled with β-TCP showed the least bone fill after 2 and 4 weeks, and faster degradation of the β-TCP particles over 4 weeks compared with defects filled with rhPDGF-BB/β-TCP. Percentage of new mineralized bone was comparable in defects to blood clot alone and β-TCP after 4 weeks of healing, but there was a collapse in the defect area in defects with blood clot alone. In comparison, the space was maintained when β-TCP was used in defects at 4 weeks. Defects which had β-TCP alone showed an inhibition in bone healing at 2 and 4 weeks; however, the combination of rhPDGF-BB with β-TCP enhanced bone regeneration in these peri-implant bone defects at the same time intervals. © 2011 John Wiley & Sons A/S.

  8. MRI and CT features of hyperplastic callus in osteogenesis imperfecta tarda

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, I. [Diagnostic Center Meidling, Vienna (Austria); Seidl, G. [Diagnostic Center Meidling, Vienna (Austria)]|[Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria); Grill, F. [Orthopaedisches Spital Wien Speising, Vienna (Austria)

    1999-05-01

    We describe the MRI and CT findings of hyperplastic callus formation simulating a tumour of pelvis in patient with osteogenesis imperfecta tarda. Possible differential diagnoses and the impact of different imaging techniques on the correct diagnosis are discussed. (orig.) With 3 figs., 5 refs.

  9. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  10. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  11. Variance analysis of x-ray CT sinograms in the presence of electronic noise background.

    Science.gov (United States)

    Ma, Jianhua; Liang, Zhengrong; Fan, Yi; Liu, Yan; Huang, Jing; Chen, Wufan; Lu, Hongbing

    2012-07-01

    Low-dose x-ray computed tomography (CT) is clinically desired. Accurate noise modeling is a fundamental issue for low-dose CT image reconstruction via statistics-based sinogram restoration or statistical iterative image reconstruction. In this paper, the authors analyzed the statistical moments of low-dose CT data in the presence of electronic noise background. The authors first studied the statistical moment properties of detected signals in CT transmission domain, where the noise of detected signals is considered as quanta fluctuation upon electronic noise background. Then the authors derived, via the Taylor expansion, a new formula for the mean-variance relationship of the detected signals in CT sinogram domain, wherein the image formation becomes a linear operation between the sinogram data and the unknown image, rather than a nonlinear operation in the CT transmission domain. To get insight into the derived new formula by experiments, an anthropomorphic torso phantom was scanned repeatedly by a commercial CT scanner at five different mAs levels from 100 down to 17. The results demonstrated that the electronic noise background is significant when low-mAs (or low-dose) scan is performed. The influence of the electronic noise background should be considered in low-dose CT imaging.

  12. Thyroid Dysfunction and Fibrin Network Structure: A Mechanism for Increased Thrombotic Risk in Hyperthyroid Individuals

    NARCIS (Netherlands)

    Hooper, J. M. W.; Stuijver, D. J. F.; Orme, S. M.; van Zaane, B.; Hess, K.; Gerdes, V. E.; Phoenix, F.; Rice, P.; Smith, K. A.; Alzahrani, S. H.; Standeven, K. F.; Ajjan, R. A.

    2012-01-01

    Context: Hyperthyroidism is associated with increased thrombosis risk, and fibrin clot structure determines susceptibility to vascular thrombotic events. Objective: Our objective was to investigate clot formation and lysis in hyperthyroidism using observational and interventional studies. Design: Ex

  13. Formation of multifunctional Fe3O4/Au composite nanoparticles for dual-mode MR/CT imaging applications

    International Nuclear Information System (INIS)

    Hu Yong; Li Jing-Chao; Shen Ming-Wu; Shi Xiang-Yang

    2014-01-01

    Recent advances with iron oxide/gold (Fe 3 O 4 /Au) composite nanoparticles (CNPs) in dual-modality magnetic resonance (MR) and computed tomography (CT) imaging applications are reviewed. The synthesis and assembly of “dumbbelllike” and “core/shell” Fe 3 O 4 /Au CNPs is introduced. Potential applications of some developed Fe 3 O 4 /Au CNPs as contrast agents for dual-mode MR/CT imaging applications are described in detail. (topical review - magnetism, magnetic materials, and interdisciplinary research)

  14. CtIP Mutations Cause Seckel and Jawad Syndromes.

    Directory of Open Access Journals (Sweden)

    Per Qvist

    2011-10-01

    Full Text Available Seckel syndrome is a recessively inherited dwarfism disorder characterized by microcephaly and a unique head profile. Genetically, it constitutes a heterogeneous condition, with several loci mapped (SCKL1-5 but only three disease genes identified: the ATR, CENPJ, and CEP152 genes that control cellular responses to DNA damage. We previously mapped a Seckel syndrome locus to chromosome 18p11.31-q11.2 (SCKL2. Here, we report two mutations in the CtIP (RBBP8 gene within this locus that result in expression of C-terminally truncated forms of CtIP. We propose that these mutations are the molecular cause of the disease observed in the previously described SCKL2 family and in an additional unrelated family diagnosed with a similar form of congenital microcephaly termed Jawad syndrome. While an exonic frameshift mutation was found in the Jawad family, the SCKL2 family carries a splicing mutation that yields a dominant-negative form of CtIP. Further characterization of cell lines derived from the SCKL2 family revealed defective DNA damage induced formation of single-stranded DNA, a critical co-factor for ATR activation. Accordingly, SCKL2 cells present a lowered apoptopic threshold and hypersensitivity to DNA damage. Notably, over-expression of a comparable truncated CtIP variant in non-Seckel cells recapitulates SCKL2 cellular phenotypes in a dose-dependent manner. This work thus identifies CtIP as a disease gene for Seckel and Jawad syndromes and defines a new type of genetic disease mechanism in which a dominant negative mutation yields a recessively inherited disorder.

  15. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  16. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  17. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  18. DIPNECH: when to suggest this diagnosis on CT

    International Nuclear Information System (INIS)

    Chassagnon, G.; Favelle, O.; Marchand-Adam, S.; De Muret, A.; Revel, M.P.

    2015-01-01

    Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia (DIPNECH) is an under-recognized disease characterized by proliferation of neuroendocrine cells in the bronchial wall. It is considered a pre-invasive lesion for lung carcinoid tumours and is found in 5.4% of patients undergoing surgical resection for lung carcinoid tumours. Other manifestations of DIPNECH include bronchial obstruction and formation of tumorlets. DIPNECH preferentially affects middle-aged women. Patients are either asymptomatic or present with long-standing dyspnoea due to obstructive syndrome that can be mistaken for asthma. At CT, mosaic attenuation with multiple small nodules is very suggestive of DIPNECH. The aim of this review is to describe DIPNECH-related CT features and correlate them with histology, in order to help radiologists suggest this diagnosis and distinguish DIPNECH from other causes of mosaic perfusion

  19. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  20. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  1. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  2. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  3. X-Ray longitudinal and computed tomography in the diagnosis of peripheral tumor-like formations of the lungs

    International Nuclear Information System (INIS)

    Sokolov, V.A.; Kartashov, V.M.; Piven', A.I.; Krasnoborova, S.Yu.; Blinova, L.V.; Savel'ev, A.V.

    1997-01-01

    Fifty eight patients with peripheral tumor-like formations of the lung (33 with cancer and 25 with benign formations) were examined by longitudinal tomography and CT. The potentialities f the two techniques in detecting the major semiotic signs of cancer and malignant formations were compared. The main or major signs, such as the shape of shadow and the pattern of outlines, which make it possible to differentiate bening and malignant formations, are virtually equally imaged by the two techniques. CT is superior to X-ray longitudinal tomography in revealing minor calcifications and microdestructions, hyperplastic intrathoracic lymph nodes. The significance of some symptoms for differential diagnosis calls for further clarification

  4. The current state of adverse event reporting in hemophilia

    NARCIS (Netherlands)

    van Vulpen, Lize F D; Saccullo, Giorgia; Iorio, Alfonso; Makris, Michael

    INTRODUCTION: Replacement of the missing clotting factor is the mainstay of hemophilia treatment. Whilst historically many hemophilia patients were infected with blood-borne viruses transmitted via plasma-derived products, nowadays the formation of alloantibodies against the missing clotting factor

  5. Treatment of Knee Osteochondral Lesions Using a Novel Clot of Autologous Plasma Rich in Growth Factors Mixed with Healthy Hyaline Cartilage Chips and Intra-Articular Injection of PRGF.

    Science.gov (United States)

    Cugat, Ramón; Alentorn-Geli, Eduard; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Cuscó, Xavier; Seijas, Roberto; Barastegui, David; Navarro, Jordi; Laiz, Patricia; García-Balletbó, Montserrat

    2017-01-01

    Knee cartilage or osteochondral lesions are common and challenging injuries. To date, most symptomatic lesions warrant surgical treatment. We present two cases of patients with knee osteochondral defects treated with a one-step surgical procedure consisting of an autologous-based matrix composed of healthy hyaline cartilage chips, mixed plasma poor-rich in platelets clot, and plasma rich in growth factors (PRGF). Both patients returned to playing soccer at the preinjury activity level and demonstrated excellent defect filling in both magnetic resonance imaging and second-look arthroscopy (in one of them). The use of a clot of autologous plasma poor in platelets with healthy hyaline cartilage chips and intra-articular injection of plasma rich in platelets is an effective, easy, and cheap option to treat knee cartilage injuries in young and athletic patients.

  6. Treatment of Knee Osteochondral Lesions Using a Novel Clot of Autologous Plasma Rich in Growth Factors Mixed with Healthy Hyaline Cartilage Chips and Intra-Articular Injection of PRGF

    Directory of Open Access Journals (Sweden)

    Ramón Cugat

    2017-01-01

    Full Text Available Knee cartilage or osteochondral lesions are common and challenging injuries. To date, most symptomatic lesions warrant surgical treatment. We present two cases of patients with knee osteochondral defects treated with a one-step surgical procedure consisting of an autologous-based matrix composed of healthy hyaline cartilage chips, mixed plasma poor-rich in platelets clot, and plasma rich in growth factors (PRGF. Both patients returned to playing soccer at the preinjury activity level and demonstrated excellent defect filling in both magnetic resonance imaging and second-look arthroscopy (in one of them. The use of a clot of autologous plasma poor in platelets with healthy hyaline cartilage chips and intra-articular injection of plasma rich in platelets is an effective, easy, and cheap option to treat knee cartilage injuries in young and athletic patients.

  7. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  8. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  9. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  10. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  11. Post mortem CT scans as a supplementary teaching method in gross anatomy.

    Science.gov (United States)

    Buenting, Mara; Mueller, Tjark; Raupach, Tobias; Luers, Georg; Wehrenberg, Uwe; Gehl, Axel; Anders, Sven

    2016-11-01

    Despite increasing the integration of radiologic imaging teaching in anatomy dissection courses, studies on learning outcome of these interventions are rare or have certain shortcomings in study design. In this study, students were randomly allocated to an intervention group (n=53) receiving five weekly CT-courses of 30min duration during a 6-week gross anatomy course. Students in the control group (n=329) received no additional teaching. Total teaching time did not differ among groups. All students were asked to participate in a pre- and post-course self-assessment (comparative self-assessment; CSA) of learning objectives related to anatomical spatial relationships and a post-course formative assessment on radiologic anatomy. Items of both assessments were matched. Moreover, students of the intervention group were asked to evaluate the CT-courses. Most participants of the intervention group classified the CT-courses as "good" or "very good". Nevertheless, results of the CSA and formative assessment did not differ among study and control groups. These findings indicate that the teaching intervention (CT-courses) did not have an impact on recognition of anatomical structures in radiological images beyond the knowledge acquired in the anatomical dissection course. As a consequence, interventions integrating radiology imaging into dissection courses should be based on psychological considerations of how to best foster student learning. Learning outcome has to be monitored, as results of evaluation surveys can be misleading. Further research on curricular concepts is needed considering both short- and long-term effects. Copyright © 2016 Elsevier GmbH. All rights reserved.

  12. Stabilization and activation of alpha-chymotrypsin in water-organic solvent systems by complex formation with oligoamines.

    Science.gov (United States)

    Kudryashova, Elena V; Artemova, Tatiana M; Vinogradov, Alexei A; Gladilin, Alexander K; Mozhaev, Vadim V; Levashov, Andrey V

    2003-04-01

    Formation of enzyme-oligoamine complexes was suggested as an approach to obtain biocatalysts with enhanced resistance towards inactivation in water-organic media. Complex formation results in broadening (by 20-40% v/v ethanol) of the range of cosolvent concentrations where the enzyme retains its catalytic activity (stabilization effect). At moderate cosolvent concentrations (20-40% v/v) complex formation activates the enzyme (by 3-6 times). The magnitude of activation and stabilization effects increases with the number of possible electrostatic contacts between the protein surface and the molecules of oligoamines (OA). Circular dichroism spectra in the far-UV region show that complex formation stabilizes protein conformation and prevents aggregation in water-organic solvent mixtures. Two populations of the complexes with different thermodynamic stabilities were found in alpha-chymotrypsin (CT)-OA systems depending on the CT/OA ratio. The average dissociation constants and stoichiometries of both low- and high-affinity populations of the complexes were estimated. It appears that it is the low-affinity sites on the CT surface that are responsible for the activation effect.

  13. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  14. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  15. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  16. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  17. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  18. Characterization of compact-toroid injection during formation, translation, and field penetration

    Science.gov (United States)

    Matsumoto, T.; Roche, T.; Allfrey, I.; Sekiguchi, J.; Asai, T.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.

    2016-11-01

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ˜1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  19. Characterization of compact-toroid injection during formation, translation, and field penetration

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, T., E-mail: cstd14003@g.nihon-u.ac.jp; Sekiguchi, J.; Asai, T. [Nihon University, Chiyoda-ku, Tokyo 101-8308 (Japan); Roche, T.; Allfrey, I.; Gota, H.; Cordero, M.; Garate, E.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States); Tajima, T. [Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States); Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States)

    2016-11-15

    We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

  20. An imaging checklist for pre-FESS CT: framing a surgically relevant report

    Energy Technology Data Exchange (ETDEWEB)

    Vaid, S., E-mail: vaids@vsnl.co [Department of Radiology and Imaging, Grant Medical Foundation, Pune (India); Vaid, N. [Department of Otorhinolaryngology, K.E.M. Hospital, Pune (India); Rawat, S. [Department of Radiology and Imaging, Grant Medical Foundation, Pune (India); Ahuja, A.T. [Department of Diagnostic Radiology and Organ Imaging, The Chinese University of Hong Kong (Hong Kong)

    2011-05-15

    The reference standard for preoperative imaging in functional endoscopic sinus surgery (FESS) is multiplanar high-resolution computed tomography (HRCT). Surgeons require a precise preoperative anatomical road map, and hence it is essential for radiologists to be familiar with the normal three-dimensional sinonasal anatomy and the normal variants encountered in this region. Sagittal imaging has recently emerged as an important tool to visualize additional details in this critical anatomical region. Radiologists also need to report these examinations with special focus on the surgeon's expectations. Constant communication between the radiologist and the surgeon helps to resolve specific issues and improve the overall quality of reports. This results in better preoperative patient counselling and in predicting postoperative improvement in clinical status. This review provides a basic structured format for reporting pre-FESS CT, which can be tailored to meet individual requirements. The CT reporting format follows the order in which the sinonasal structures are approached during surgery.

  1. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  3. Lesser sac hematoma as a sign of rupture of hepatocellular carcinoma in the caudate lobe

    International Nuclear Information System (INIS)

    Iwasaki, Yoshie; Tani, Ichiro; Nakajima, Yasuo; Ishikawa, Tohru; Umeda, Satoshi; Kusano, Shoichi

    2001-01-01

    The purpose of this study was to evaluate the CT findings of rupture of hepatocellular carcinoma (HCC) in the caudate lobe of the liver. The CT scans of five cases of rupture of HCC in the caudate lobe of the liver were retrospectively reviewed and correlated with clinical records. All cases showed exophytic tumors in the caudate lobe of the liver and high-attenuation hematomas in the lesser sac on CT. A lesser sac hematoma may be a sentinel clot sign of rupture of HCC in the caudate lobe. (orig.)

  4. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  5. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  6. Hemostasia normal y coagulación intravascular diseminada en obstetricia Normal hemostasis and disseminated intravascular clotting in Obstetrics

    Directory of Open Access Journals (Sweden)

    Danilo Nápoles Méndez

    2012-03-01

    Full Text Available En el período gravido - puerperal, la coagulación sanguínea sufre cambios que se impone conocer para interpretar correctamente esos trastornos cuando se presentan en esta etapa, teniendo en cuenta las posibles complicaciones y el peligro para la vida que pueden presentarse. El objetivo del presente artículo es proporcionar a los obstetras una revisión bibliográfica que les permita actualizarse acerca del tema y facilite su modo de actuación ante pacientes con coagulación intravascular diseminada. Se concluye que es preciso diagnosticar tempranamente el proceso en la fase bioquímica de bajo grado y aplicar en las féminas el tratamiento expedito de la enfermedad de base para eliminar las complicaciones o disminuir su ocurrenciaIn the period from pregnancy to puerperium, blood clotting suffers changes which are important to be known in order to interpret correctly those dysfunctions when they appear in this stage, keeping in mind the possible complications and the danger for life which can take place. The objective of the present work is to provide the obstetricians a literature review that allows them to be updated about the topic and facilitate their performance in case of patients with disseminated intravascular clotting. It is concluded that it is necessary to have an early diagnosis on the process during the low grade biochemical phase and to apply in these women the expedite treatment of the base disease to eliminate complications or to decrease their occurrence.

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  8. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  9. Development of haemostatic decontaminants for the treatment of wounds contaminated with chemical warfare agents. 1: evaluation of in vitro clotting efficacy in the presence of certain contaminants.

    Science.gov (United States)

    Hall, Charlotte A; Lydon, Helen L; Dalton, Christopher H; Chipman, J K; Graham, John S; Chilcott, Robert P

    2015-05-01

    The treatment of penetrating, haemorrhaging injuries sustained within a hazardous environment may be complicated by contamination with toxic chemicals. There are currently no specific medical countermeasures for such injuries. Haemostats with an absorbent mechanism of action have the potential to simultaneously stop bleeding and decontaminate wounds. However, a primary requirement of a 'haemostatic decontaminant' is the retention of clotting function in the presence of chemical contaminants. Thus, the aim of this study was to investigate the haemostatic efficacy of seven commercially available haemostats in the presence of toxic chemicals (soman, VX, sulphur mustard, petrol, aviation fuel and motor oil). Clot viscosity was assessed ex vivo using thrombelastography following treatment of pig blood with: (i) toxic chemical; (ii) haemostat; or (iii) haemostat in combination with toxic chemical. Several contaminants (VX, petrol and GD) were found to be pro-haemostatic and none had an adverse effect on the rate with which the test products attained haemostasis. However, the total clot strength for blood treated with certain haemostats in the presence of sulphur mustard, soman and petrol was significantly decreased. Three test products failed to demonstrate haemostatic function in this ex vivo (thrombelastography) model; this was tentatively ascribed to the products achieving haemostasis through a tamponade mechanism of action, which can only be replicated using in vivo models. Overall, this study has identified a number of commercial products that may have potential as haemostatic decontaminants and warrant further investigation to establish their decontaminant efficacy. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  11. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  12. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  13. Is higher body temperature beneficial in ischemic stroke patients with normal admission CT angiography of the cerebral arteries?

    Science.gov (United States)

    Kvistad, Christopher Elnan; Khanevski, Andrej; Nacu, Aliona; Thomassen, Lars; Waje-Andreassen, Ulrike; Naess, Halvor

    2014-01-01

    Low body temperature is considered beneficial in ischemic stroke due to neuroprotective mechanisms, yet some studies suggest that higher temperatures may improve clot lysis and outcomes in stroke patients treated with tissue plasminogen activator (tPA). The effect of increased body temperature in stroke patients treated with tPA and with normal computed tomography angiography (CTA) on admission is unknown. We hypothesized a beneficial effect of higher body temperature in the absence of visible clots on CTA, possibly due to enhanced lysis of small, peripheral clots. Patients with ischemic stroke admitted to our Stroke Unit between February 2006 and April 2013 were prospectively registered in a database (Bergen NORSTROKE Registry). Ischemic stroke patients treated with tPA with normal CTA of the cerebral arteries were included. Outcomes were assessed by the modified Rankin Scale (mRS) after 1 week. An excellent outcome was defined as mRS=0, and a favorable outcome as mRS=0-1. A total of 172 patients were included, of which 48 (27.9%) had an admission body temperature ≥37.0°C, and 124 (72.1%) had a body temperature temperature ≥37.0°C was independently associated with excellent outcomes (odds ratio [OR]: 2.8; 95% confidence interval [CI]: 1.24-6.46; P=0.014) and favorable outcomes (OR: 2.8; 95% CI: 1.13-4.98; P=0.015) when adjusted for confounders. We found an association between higher admission body temperature and improved outcome in tPA-treated stroke patients with normal admission CTA of the cerebral arteries. This may suggest a beneficial effect of higher body temperature on clot lysis in the absence of visible clots on CTA.

  14. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    International Nuclear Information System (INIS)

    Mortele, Koenraad J.; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R.

    2004-01-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established

  15. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  16. A megavoltage CT scanner for radiotherapy verification

    International Nuclear Information System (INIS)

    Lewis, D.G.; Swindell, W.; Morton, E.J.; Evans, P.M.; Xiao, Z.R.

    1992-01-01

    The authors have developed a system for generating megavoltage CT images immediately prior to the administration of external beam radiotherapy. The detector is based on the scanner of Simpson (Simpson et al 1982) - the major differences being a significant reduction in dose required for image formation, faster image formation and greater convenience of use in the clinical setting. Attention has been paid to the problem of ring artefacts in the images. Specifically, a Fourier-space filter has been applied to the sinogram data. After suitable detector calibration, it has been shown that the device operates close to its theoretical specification of 3 mm spatial resolution and a few percent contrast resolution. Ring artefacts continue to be a major source of image degradation. A number of clinical images are presented. (author)

  17. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  18. Transgenic rabbits as a model organism for production of human clotting factor VIII

    International Nuclear Information System (INIS)

    Vasicek, D.; Chrenek, P.; Makarevich, A.; Bauer, M.; Jurcik, R.; Suvegova, K.; Rafay, J.; Bulla, J.; Hetenyi, L.; Erickson, J.; Paleyanda, R.K.

    2005-01-01

    Human clotting factor VIII (hFVIII) is a very complex and large protein whose expression is difficult, as hFVIII requires extensive post-translational modification to be biologically active. This paper reports the generation of transgenic rabbits as a model species for testing the expression of hFVIII in the mammary gland. For micro-injection, a fusion gene construct was used, consisting of 2.5 kb murine whey acidic protein (mWAP) promoter, 7.2 kb cDNA of hFVIII, and 4.6 kb of 3' flanking sequences of the mWAP gene. from 130 micro-injected zygotes transferred into recipients, 30 offspring were delivered. The pups were screened for the transgene by PCR, using DNA isolated from the ear, and results were confirmed by Southern blot analysis. The transgene was identified in one female founder animal, and it was transmitted to the offspring in a Mendelian fashion, thus demonstrating stable integration of the gene construct into the germline of the transgenic rabbits. (author)

  19. The euglobulin clot lysis time to assess the impact of nanoparticles on fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Minet, Valentine, E-mail: valentine.minet@unamur.be; Alpan, Lutfiye; Mullier, François [University of Namur – UNamur, Department of Pharmacy, Namur Thrombosis and Hemostasis Center (NTHC), Namur Nanosafety Center (NNC), NAmur Research Institute for Life Sciences NARILIS (Belgium); Toussaint, Olivier [Laboratory of Cellular Biochemistry and Biology (URBC) (Belgium); Lucas, Stéphane [University of Namur (UNamur), Research Centre for the Physics of Matter and Radiation (PMR-LARN), Namur Nanosafety Center NNC, NAmur Research Institute for Life Sciences NARILIS (Belgium); Dogné, Jean-Michel; Laloy, Julie, E-mail: julie.laloy@unamur.be [University of Namur – UNamur, Department of Pharmacy, Namur Thrombosis and Hemostasis Center (NTHC), Namur Nanosafety Center (NNC), NAmur Research Institute for Life Sciences NARILIS (Belgium)

    2015-07-15

    Nanoparticles (NPs) are developed for many applications in various fields, including nanomedicine. The NPs used in nanomedicine may disturb homeostasis in blood. Secondary hemostasis (blood coagulation) and fibrinolysis are complex physiological processes regulated by activators and inhibitors. An imbalance of this system can either lead to the development of hemorrhages or thrombosis. No data are currently available on the impact of NPs on fibrinolysis. The objectives of this study are (1) to select a screening test to study ex vivo the impact of NPs on fibrinolysis and (2) to test NPs with different physicochemical properties. Euglobulin clot lysis time test was selected to screen the impact of some NPs on fibrinolysis using normal pooled plasma. A dose-dependent decrease in the lysis time was observed with silicon dioxide and silver NPs without disturbing the fibrin network. Carbon black, silicon carbide, and copper oxide did not affect the lysis time at the tested concentrations.

  20. Low-grade endotoxemia and clotting activation in the early phase of pneumonia.

    Science.gov (United States)

    Cangemi, Roberto; Della Valle, Patrizia; Calvieri, Camilla; Taliani, Gloria; Ferroni, Patrizia; Falcone, Marco; Carnevale, Roberto; Bartimoccia, Simona; D'Angelo, Armando; Violi, Francesco

    2016-11-01

    Community-acquired pneumonia (CAP) is associated with an increased risk of arterial and venous thrombosis but the underlying pathophysiological mechanisms are still unclear. We investigated if, in patients with CAP, a pro-thrombotic state does exist and its relationship with serum levels of endotoxins. A total of 104 consecutive patients with CAP were prospectively recruited and followed up until discharge. At admission and at discharge, serum endotoxins, systemic markers of clotting activation and zonulin, a marker of gut permeability, were analysed. Hospitalized patients matched for gender, age and comorbidities but without infections were used as control. At admission, CAP patients showed higher plasma levels of F 1 +2 , a marker of thrombin generation (P = 0.023), and lower levels of protein C (PC; P zonulin were higher in CAP patients than controls (P zonulin was detected (R = 0.575; P < 0.001) CONCLUSION: This study provides the first evidence that CAP patients disclose an ongoing pro-thrombotic state and suggests a role for endotoxemia in determining enhanced thrombin generation. © 2016 Asian Pacific Society of Respirology.

  1. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  2. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  3. Brain hemorrhage associated with maintenance hemodialysis. CT analysis of 19 cases

    International Nuclear Information System (INIS)

    Kawahata, Nobuya

    1994-01-01

    The CT findings of 19 hemodialyzed patients with brain hemorrhage (BH) were evaluated. The 30-day mortality rate was 78.9%. The lesion locations in the 19 cases with BH were putaminal hemorrhage in 8 patients, putaminothalamic (mixed) hemorrhage in 7, thalamic hemorrhage in one, subcortical hemorrhage in one, and cerebellar hemorrhage in one. In the remaining patient, the bleeding was confined to the ventricular system. One remarkable CT finding was the formation of a massive hematoma in most cases. In some cases, the hematoma occupied the greater part of one cerebral hemisphere. Oral anticoagulants and/or antiplatelet drugs, and intravenous heparinization could produce massive accumulations of blood in the brain parenchyma. The second major finding was the low CT absorption values of the hematoma at the acute stage, as compared to that of hypertensive BH. This decreased absorption density resulted from a low hemoglobin concentration in the hematoma itself due to the severe anemia occurring in patients on long-term maintenance hemodialysis. (author)

  4. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  5. Low level of procoagulant platelet microparticles is associated with impaired coagulation and transfusion requirements in trauma patients

    DEFF Research Database (Denmark)

    Windeløv, Nis Agerlin; Johansson, Pär Ingemar; Sørensen, Anne Marie

    2014-01-01

    BACKGROUND: Following activation, platelets release small vesicles called platelet-derived microparticles (PMPs). PMPs accelerate thrombin generation and thus clot formation at sites of injury by exposing the procoagulant membrane phospholipid phosphatidylserine (PS). The role of PMPs in coagulop......BACKGROUND: Following activation, platelets release small vesicles called platelet-derived microparticles (PMPs). PMPs accelerate thrombin generation and thus clot formation at sites of injury by exposing the procoagulant membrane phospholipid phosphatidylserine (PS). The role of PMPs...

  6. Superior facet syndrome. Findings on metrizamide CT myelography

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Yoshichika; Igarashi, Seishi; Koyama, Tsunemaro

    1985-02-01

    Sciatica caused by root entrapment in the lateral recess was named superior facet syndrome by Epstein in 1972. Few reports on this subject based on large numbers of cases have been documented to date. Of the patients with sciatica, 32 patients were diagnosed to have root entrapment at the lateral recess L5 or/and S1 lumbar spine. Out of 32 patients, 20 patients were operated on and the lateral entrapment was recognized in all of surgical cases. Neuroradiological findings, especially of metrizamide CT (met. CT), were documented in detail. Thirty two patients were classified in three types according to radiological findings. They were congenital or developmental, degenerative, and combined type, respectively. Fourteen cases belonged to the congenital type, 13 to the degenerative and 5 to the combined type. Each group had the mean ages of 23.4, 53.8, and 36.8 years old, respectively. Of 32 cases the entrapment occured in 47 L5 roots and 11 S1 roots. There was no remarkable laterality. In operation the unroofing of the lateral recess were done and the sciatica subsided postoperatively in all of surgical cases. Met. CT revealed extreme medial protrusion of the superior articular joint in 18 of 24 cases(75%) and none filling of the root in the lateral recess in 21 of 24 cases (87.5%). In the degenerative type, met. CT showed some degenerative changes that were hypertrophy or deformity of the articular joints and spur formation of the vertebral body. In contrast to met. CT, metrizamide myelography revealed only slight changes, which were poor filling of the root before it turned out the pedicle of lateral compression of the root. In plain films or lumbar spine articular joints at Lsub(4/5) were formed in coronal plane in 69% of cases of the L5 root entrapment. Met. CT using ReView technique was of great diagnostic value in superior facet syndrome.

  7. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  8. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  9. Reconstructing the CT number array from gray-level images and its application in PACS

    Science.gov (United States)

    Chen, Xu; Zhuang, Tian-ge; Wu, Wei

    2001-08-01

    Although DICOM compliant computed tomography has been prevailing in medical fields nowadays, there are some incompliant ones, from which we could hardly get the raw data and make an apropos interpretation due to the proprietary image format. Under such condition, one usually uses frame grabbers to capture CT images, the results of which could not be freely adjusted by radiologists as the original CT number array could. To alleviate the inflexibility, a new method is presented in this paper to reconstruct the array of CT number from several gray-level images acquired under different window settings. Its feasibility is investigated and a few tips are put forward to correct the errors caused respectively by 'Border Effect' and some hardware problems. The accuracy analysis proves it a good substitution for original CT number array acquisition. And this method has already been successfully used in our newly developing PACS and accepted by the radiologists in clinical use.

  10. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  11. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  12. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  13. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  14. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  15. Radiology metrics for safe use and regulatory compliance with CT imaging

    Science.gov (United States)

    Paden, Robert; Pavlicek, William

    2018-03-01

    The MACRA Act creates a Merit-Based Payment System, with monitoring patient exposure from CT providing one possible quality metric for meeting merit requirements. Quality metrics are also required by The Joint Commission, ACR, and CMS as facilities are tasked to perform reviews of CT irradiation events outside of expected ranges, review protocols for appropriateness, and validate parameters for low dose lung cancer screening. In order to efficiently collect and analyze irradiation events and associated DICOM tags, all clinical CT devices were DICOM connected to a parser which extracted dose related information for storage into a database. Dose data from every exam is compared to the appropriate external standard exam type. AAPM recommended CTDIvol values for head and torso, adult and pediatrics, coronary and perfusion exams are used for this study. CT doses outside the expected range were automatically formatted into a report for analysis and review documentation. CT Technologist textual content, the reason for proceeding with an irradiation above the recommended threshold, is captured for inclusion in the follow up reviews by physics staff. The use of a knowledge based approach in labeling individual protocol and device settings is a practical solution resulting in efficiency of analysis and review. Manual methods would require approximately 150 person-hours for our facility, exclusive of travel time and independent of device availability. An efficiency of 89% time savings occurs through use of this informatics tool including a low dose CT comparison review and low dose lung cancer screening requirements set forth by CMS.

  16. DNA end resection by CtIP and exonuclease 1 prevents genomic instability

    DEFF Research Database (Denmark)

    Eid, Wassim; Steger, Martin; El-Shemerly, Mahmoud

    2010-01-01

    End resection of DNA-which is essential for the repair of DNA double-strand breaks (DSBs) by homologous recombination-relies first on the partnership between MRE11-RAD50-NBS1 (MRN) and CtIP, followed by a processive step involving helicases and exonucleases such as exonuclease 1 (EXO1). In this s......End resection of DNA-which is essential for the repair of DNA double-strand breaks (DSBs) by homologous recombination-relies first on the partnership between MRE11-RAD50-NBS1 (MRN) and CtIP, followed by a processive step involving helicases and exonucleases such as exonuclease 1 (EXO1...... of DNA-PK-dependent radial chromosome formation. Thus, our study identifies new functions of CtIP and EXO1 in DNA end resection and provides new information on the regulation of DSB repair pathways, which is a key factor in the maintenance of genome integrity....

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  19. Clinical utility of FDG PET/CT in acute complicated pyelonephritis - results from an observational study

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Hsing [Mackay Memorial Hospital at Taipei, Department of Nuclear Medicine, Taipei (China); Tseng, Jing-Ren; Yen, Tzu-Chen [Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan (China); Lee, Ming-Hsun [Chang Gung Memorial Hospital at Linkou, Division of Infectious Diseases, Department of Internal Medicine, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou, Biostatistics Unit, Clinical Trial Center, Taoyuan (China)

    2018-03-15

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of {sup 18}F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course. (orig.)

  20. Formation of a compact toroid for enhanced efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Mozgovoy, A. G. [P.N. Lebedev Physical Institute, Moscow 119991 (Russian Federation); Romadanov, I. V.; Ryzhkov, S. V., E-mail: ryzhkov@power.bmstu.ru [Bauman Moscow State Technical University, Moscow 105005 (Russian Federation)

    2014-02-15

    We report here our results on the formation of a plasma configuration with the generic name of compact toroid (CT). A method of compact toroid formation to confine, heat and compress a plasma is investigated. Formation of a compact torus using an additional toroidal magnetic field helps to increase the plasma current to a maintainable level of the original magnetic field. We design the Compact Toroid Challenge (CTC) experiment in order to improve the magnetic flux trapping during field reversal in the formation of a compact toroid. The level of the magnetic field immersed in the plasma about 70% of the primary field is achieved. The CTC device and scheme of high level capturing of magnetic flux are presented.

  1. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  2. CT ESP for Yme, Converting the Yme field offshore Norway from a conventional rig-operated field to CT-operated for workover and drilling applications

    Energy Technology Data Exchange (ETDEWEB)

    Baklid, A.; Apeland, O. J.; Teigen, A. S. [Statoil (Norway)

    1998-12-31

    Conventional tubing deployed electrical submersible pump (ESP) was the original choice as the artificial lift method for the Yme field offshore Norway. Several operational problems experienced over the past two years, such as formation damage, complicated and costly workovers and limited access to the reservoir, combined with revised field requirements and a reevaluation of artificial lift methods resulted in a change in completion philosophy. Following these reassessments coiled tubing ESPs utilizing internal power cable were installed and became the preferred method. This paper provides an assessment of the value of installing CT-ESP in a live well, and describes the system design for a true underbalanced CT-ESP installation. Well control and barrier philosophy during installation, production and workover mode is also evaluated. 2 refs., 3 tabs., 5 figs.

  3. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  4. CT findings of pancreatic disease

    International Nuclear Information System (INIS)

    Lee, Mi Sook; Park, In Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song; Won, Jong Jin

    1988-01-01

    CT was found to be a reliable, often specific, and noninvasive method for detecting pancreatic diseases. In a study of pancreatic lesions, 37 cases having satisfactory operative and histological proofs were analyzed by CT at PMC from Jan. 1986 to Oct. 1987. The results were as following: 1. Male:female is 26:11. 2. The incidence of pancreatic disease were as follows: 1) Pancreatic cancer:21 cases (56%) a.Head:12 cases b.Body:4 cases c.Tail:1 case d.Body and tail:1 case e.Uncinate process:2 cases f.Entire pancreas: 1 case 2) Acute pancreatitis: 6 cases (16%) 3) Chronic pancreatitis:5 cases (14%) 3. The characteristic CT findings: 1) 100% of pancreatic head cancer showed focal mass or alteration of pancreatic head contour and biliary tree dilatation, and 33% (7/12) fat line obliteration. 2) All of other pancreatic cancer except head appeared as focal mass or contour alteration and fat line obliteration. 3) Total 6 cases of acute pancreatitis showed that 5 cases diffuse enlargement of pancreas, 3 fluid collection (2 cases:left anterior pararenal and posterior pararenal space and lesser sac, 1 case:only pancreas body) and 1 case abscess formation. 4) Total 5 cases of chronic pancreatitis revealed diffuse enlargement 2 cases and atrophy 1 case, pancreatic ductal dilatation 3 cases, calcification 2 cases, and biliary tree dilatation with CBD tapering appearance 1 case. 5) All cases of pseudocysts were well marginated cystic lesions that located at head in 3 cases and tail 3 cases, and 4 cases were well defined pure cystic masses but 1 case was well capsulated cyst with multiple internal septation

  5. 18F FDG PET/CT for staging of colorectal carcinoma - literature review and case report

    International Nuclear Information System (INIS)

    Ilcheva, M.; Hadzhiyska, V.; Petrov, T.; Mladenov, K.; Malla, V.; Zlatareva, D.; Nedevska, M.; Neychev, V.

    2017-01-01

    Colorectal cancer is the third most common cancer worldwide. The role of PET/CT in initial diagnosis of primary colorectal cancer is limited. PET is used for restaging of colorectal carcinoma or for evaluating the hepatic and pulmonary metastasis. On the other hand, MRI is used for T- and N- staging and also in the evaluation of liver metastasis. The aim of the study is to demonstrate the capabilities of the imaging modalities (PET/CT and MRI) as well as to show the importance of collaborative work of the units to determine the correct therapeutic decision. In this case, we present a 63 years old patient with rectal carcinoma. Confirmation of the disease was proven using colonoscopy and biopsy. Then we perform FDG-PET/CT on a GE Discovery 16T according to a standard protocol, using diuretic stimulation and oral contrast intake, followed by 3Tesla MRI of the abdomen and pelvis with intravenous contrast. PET/CT: data on metabolic active tumor formation in the recto-sigmoid region, liver dissemination and lesion near the navel as well as the presence of two metabolically active peritoneal lesions of small size. MRI: Rectal tumor data with a suspected infiltration of the wall of the ileum and bladder as well as dissemination in the liver and abdominal wall. Additionally, there was a thrombosis of the left branch of the portal vein. By applying both methods it is possible to accurately stage the disease and choose the most appropriate therapeutic behavior. Our impressions of the application of the two imaging methods PET/CT and MRI matches the science publications that each one has a specific application, capabilities and advantages. For example, PET/CT provide sufficient functional and morphological information for the initial staging and also for the peritoneal lesions, which are identified as non-specific and non-definite in MRI. On the other hand, after MRI we receive detailed information for the anatomic and topographic characteristic of the major tumor formation

  6. CT attenuation in normal aging and Alzheimer's disease

    International Nuclear Information System (INIS)

    Kim, W.S.; Pearlson, G.D.; Goldfinger, A.D.; Tune, L.E.; Heyler, G.

    1986-01-01

    113 screened normal volunteers aged 18-85 and 50 elderly demented individuals meeting NINCDS/ADRDA criteria for probable senile dementia of the Alzheimer type, (SDAT), received a non-contrast x-CT head scan on a single 512x512 matrix Siemens Somatom DR3 Scanner. Scanning parameters (KV,MA) were kept constant, and the authors used a specially designed head holder to ensure a uniform scanning angle. Standard 8mm thick cuts, at zero degrees to the supra-orbito-meatal line, were taken through the entire brain. A ''phantom'' consisting of plastics of several different attenuation values was scanned before each patient as a reference to correct for any numerical drift in the scanner. Both patients and controls were scanned during the same sessions to eliminate possible systematic bias, and a single CT technologist carried out all scanning. Numerical CT data were collected on magnetic tape for analysis on a specially designed image processing system. Software was used to read CT density data from the 512x512 matrix scanner output tapes and to transfer the resulting image in standardized format to hard disk on the processing system. This system consists of a PDP-11-34 computer, linked to a Gould DeAnza IP-5000 image processors, hard disk system and tape drive. Once transferred to disk, images were rated blindly to subject identity or diagnosis by another 2 separate raters using a computer-linked cursor, and digitizer tablet. These numerical attenuation data from various anatomically defined regions of interest, (ROI's), were then corrected for head size using a regression model

  7. Recurrent white thrombi formation in hemodialysis tubing: a case report.

    Science.gov (United States)

    Sathe, Kiran P; Yeo, Wee-Song; Liu, Isaac Desheng; Ekambaram, Sudha; Azar, Mohammed; Yap, Hui-Kim; Ng, Kar-Hui

    2015-01-15

    While the appearance of red clots in the dialyzer is a common phenomenon in every hemodialysis unit, the occurrence of white thrombi in the tubing is relatively rare. We describe an adolescent male with recurrent white thrombi formation in the hemodialysis tubing. This patient had chronic renal failure from focal segmental glomerulosclerosis, but was no longer nephrotic at the time of the thrombi formation. He had a history of recurrent thrombosis of his vascular access. However, no pro-thrombotic risk factors could be identified. White particulate matter, measuring 1 to 3mm in size, and adherent to the arterial and venous blood tubing lines was found during the rinse back of a hemodialysis session. This was associated with a 60% decrease in his platelet count. Light microscopic examination of the deposits revealed the presence of platelet aggregates. He subsequently developed thrombosis of his arteriovenous graft six hours later. The white thrombi recurred at the next dialysis session, as well as six months later. These episodes occurred regardless of the type of dialysis machine or tubing, and appeared to resolve with an increase in heparin dose. Recurrent white thrombi formation can occur in the hemodialysis tubing of a patient with no identifiable pro-thrombotic factors. The white thrombi may be a harbinger of arteriovenous graft thrombosis and may be prevented by an increase in heparin dose.

  8. Thrombin Avtivable Fibrinolysis Inhibitor in Venous and Arterial Thrombosis

    NARCIS (Netherlands)

    E.L.E. de Bruijne

    2011-01-01

    textabstractVenous and arterial thromboses are major causes of morbidity and mortality. Venous thrombosis is the result of pathological occlusive clot formation in the veins. It occurs mainly in the deep veins of the leg (deep vein thrombosis), from which parts of the clot frequently embolize to the

  9. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  10. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  11. Use of Clotted Human Plasma and Aprotinin in Skin Tissue Engineering: A Novel Approach to Engineering Composite Skin on a Porous Scaffold.

    Science.gov (United States)

    Paul, Michelle; Kaur, Pritinder; Herson, Marisa; Cheshire, Perdita; Cleland, Heather; Akbarzadeh, Shiva

    2015-10-01

    Tissue-engineered composite skin is a promising therapy for the treatment of chronic and acute wounds, including burns. Providing the wound bed with a dermal scaffold populated by autologous dermal and epidermal cellular components can further entice host cell infiltration and vascularization to achieve permanent wound closure in a single stage. However, the high porosity and the lack of a supportive basement membrane in most commercially available dermal scaffolds hinders organized keratinocyte proliferation and stratification in vitro and may delay re-epithelization in vivo. The objective of this study was to develop a method to enable the in vitro production of a human skin equivalent (HSE) that included a porous scaffold and dermal and epidermal cells expanded ex vivo, with the potential to be used for definitive treatment of skin defects in a single procedure. A collagen-glycosaminoglycan dermal scaffold (Integra(®)) was populated with adult fibroblasts. A near-normal skin architecture was achieved by the addition of coagulated human plasma to the fibroblast-populated scaffold before seeding cultured keratinocytes. This resulted in reducing scaffold pore size and improving contact surfaces. Skin architecture and basement membrane formation was further improved by the addition of aprotinin (a serine protease inhibitor) to the culture media to inhibit premature clot digestion. Histological assessment of the novel HSE revealed expression of keratin 14 and keratin 10 similar to native skin, with a multilayered neoepidermis morphologically comparable to human skin. Furthermore, deposition of collagen IV and laminin-511 were detected by immunofluorescence, indicating the formation of a continuous basement membrane at the dermal-epidermal junction. The proposed method was efficient in producing an in vitro near native HSE using the chosen off-the-shelf porous scaffold (Integra). The same principles and promising outcomes should be applicable to other biodegradable

  12. A comparison of high resolution CT scan of temporal bone and operative findings in middle ear cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, Tae Beom; Seong, Hun; Cheon, Mal Soon; Kim, Hack Jin; Jang, Keung Jae; Chun, Byung Hee [Dae Dong General Hospital, Busan (Korea, Republic of)

    1993-09-15

    To evaluate the value of HRCT imaging in middle ear cholesteatoma, we prospectively analysed the CT images in 28 surgically proven cases with cholesteatomas regarding main site of lesion, ossicular change, facial nerve exposure and fistula formation. The most common main site of lesion was the epitympanum (92.8%). The results of sensitivity, positive predictability, and accuracy by CT imagings were as follows: for ossicular involvement, 94.1%, 88.8%, and 86.2% in malleus, 96.0%, 88.8%, and 85.7% in incus, 81.2%, 81.2%, and 78.5% in stapes; for facial nerve exposure, 66.6%, 57.1%, and 81.2%: for fistula formation, 100%, 75.0%, and 96.4%, respectively. In conclusion, the temoral bone HRCT imaging is an accurate preoperative method in detecting main lesion site, ossicular involvement, fistula formation. Because of the low sensitivity and positive predictability in detecting facial nerve exposure, it is necessary to correlate the HRCT images with the clinical status.

  13. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  14. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    International Nuclear Information System (INIS)

    Wang, J; Chan, F; Newman, B; Larson, D; Leung, A; Fleischmann, D; Molvin, L; Marsh, D; Zorich, C; Phillips, L

    2014-01-01

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  18. CT diagnosis of splenic infarction in blunt trauma: imaging features, clinical significance and complications

    International Nuclear Information System (INIS)

    Miller, L.A.; Mirvis, S.E.; Shanmuganathan, K.; Ohson, A.S.

    2004-01-01

    AIM: The object of this study is to describe the appearance, complications, and outcome of segmental splenic infarctions occurring after blunt trauma using computed tomography (CT). MATERIALS AND METHODS: Thirteen blunt trauma patients were identified with splenic infarction on contrast-enhanced CT. CT images were retrospectively reviewed and the percentage of infarcted splenic tissue and presence of splenic injury separate from the site of infarction were identified. Splenic angiograms were reviewed and follow-up CT images were assessed for interval change in the appearance of the infarcts. RESULTS: The mean age of patients was 32 years and the most common mechanism of injury was road traffic accident. The majority (54%) had 25-50% infarction of the spleen. Splenic angiograms were performed in nine patients and seven demonstrated wedge-shaped regions of decreased perfusion corresponding to the infarction seen on CT with no need for intervention. Eleven patients underwent a follow-up CT that demonstrated the following: no significant change in six, near-complete resolution in two, delayed appearance of infarction in one, abscess formation in one, and delayed splenic rupture in one. CONCLUSION: Segmental splenic infarction is a rare manifestation of blunt splenic trauma. The diagnosis is readily made using contrast-enhanced CT. The majority will decrease in size on follow-up CT and resolve without clinical sequelae. Resolution of infarction is also seen and these cases are best described as temporary perfusion defects. Splenic abscess or delayed rupture are uncommon complications that may necessitate angiographic or surgical intervention

  19. CT diagnosis of splenic infarction in blunt trauma: imaging features, clinical significance and complications

    Energy Technology Data Exchange (ETDEWEB)

    Miller, L.A.; Mirvis, S.E.; Shanmuganathan, K.; Ohson, A.S. E-mail: lmiller@um.edu

    2004-04-01

    AIM: The object of this study is to describe the appearance, complications, and outcome of segmental splenic infarctions occurring after blunt trauma using computed tomography (CT). MATERIALS AND METHODS: Thirteen blunt trauma patients were identified with splenic infarction on contrast-enhanced CT. CT images were retrospectively reviewed and the percentage of infarcted splenic tissue and presence of splenic injury separate from the site of infarction were identified. Splenic angiograms were reviewed and follow-up CT images were assessed for interval change in the appearance of the infarcts. RESULTS: The mean age of patients was 32 years and the most common mechanism of injury was road traffic accident. The majority (54%) had 25-50% infarction of the spleen. Splenic angiograms were performed in nine patients and seven demonstrated wedge-shaped regions of decreased perfusion corresponding to the infarction seen on CT with no need for intervention. Eleven patients underwent a follow-up CT that demonstrated the following: no significant change in six, near-complete resolution in two, delayed appearance of infarction in one, abscess formation in one, and delayed splenic rupture in one. CONCLUSION: Segmental splenic infarction is a rare manifestation of blunt splenic trauma. The diagnosis is readily made using contrast-enhanced CT. The majority will decrease in size on follow-up CT and resolve without clinical sequelae. Resolution of infarction is also seen and these cases are best described as temporary perfusion defects. Splenic abscess or delayed rupture are uncommon complications that may necessitate angiographic or surgical intervention.

  20. Wormholes propagation for fractured-vuggy formation: Laboratory tests, numerical simulation and field application

    Directory of Open Access Journals (Sweden)

    Fei Liu

    2017-12-01

    Full Text Available The propagation of wormhole is vital important for matrix acidizing and acid fracturing in carbonate reservoirs. While the formation of acid dissolved wormhole is derived from heterogeneous physical and chemical transportations and reactions. Alveolate dissolved pores, krast caves, and natural fissures are the major reservoir spaces for the Sinian dolomite formation in the Anyue gas field of the Sichuan Basin. There were four categories of formation, which are matrix dominated, inter-breccia dissolved pore dominated, dissolved pore and cave dominated, and fissure and cave dominated, based on the development intensity and connectedness of caves and fissures. The caves and fissures make the wormhole formation and propagation particularly complicated. Firstly, the 3-D topological structure of dissolved pores, vugs, fissures and throats inside cores is quantitatively scanned by CT imaging technology for its feature of vivid and damage-free. Secondly, 3-D patterns of wormhole are obtained with CT scanning after core flooding by acid. Additionally, the pore-throat network model is reconstructed with digital cores technology. Then, the size and ratio of pore and throat before and after core flooding by acid is analyzed and the absolute permeability of pore scale flow is numerically simulated to understand the fundamental influence of pores and vugs distribution and connectedness on wormhole propagation. Lastly, the wormhole pattern gained by CT scanning and simulating with two-scale model is compared. Meanwhile, the corrected two-scale model is utilized to simulate the wormhole propagation for matrix acidizing and acid fracturing of Sinian fractured-vuggy dolomite in Anyue gas field, Sichuan Basin. The optimized injection rate and volume were in agreement with the characteristic matrix acidizing operating curve, which indicates that the two-scale model was suitable for matrix acidizing optimization design of such formations. In addition, the simulated

  1. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  2. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  3. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  4. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  5. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  6. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  7. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  8. Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering

    Science.gov (United States)

    Lienemann, Philipp S.; Metzger, Stéphanie; Kiveliö, Anna-Sofia; Blanc, Alain; Papageorgiou, Panagiota; Astolfo, Alberto; Pinzer, Bernd R.; Cinelli, Paolo; Weber, Franz E.; Schibli, Roger; Béhé, Martin; Ehrbar, Martin

    2015-05-01

    Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  12. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  14. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  15. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  16. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  17. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  18. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  19. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  20. Comparative Study of the CT Findings and Clinical Features in Pediatric and Adult Sialadenitis

    International Nuclear Information System (INIS)

    Han, Jong Kyu; Jo, Seong Shik; Kim, Sang Won; Kim, Young Tong; Shin, Hyeong Cheol; Kim, Il Young; Lee, Yong Man

    2010-01-01

    We wanted to compare the CT findings and clinical features of parotitis and submandibular sialadenitis in children and adults and to evaluate the statistical significance of these in different age groups and the usefulness of a CT scan. Ninety-seven adults and 36 pediatric patients with sialadenitis were included in this retrospective study. Regardless of the site of involvement, we evaluated the CT findings and clinical manifestations between the pediatric and adult groups, and between the pediatric and adult parotitis and submandibular sialadenitis groups. At last, all the patients were classified into seven age groups. Abscess formations were more prominent in the parotitis groups, and sialiths were more common in the submandibular sialadenitis group with the lowest incidence in the young children group (≤ 10 years). Cellulitis seen on a CT scan showed a higher incidence in the adult parotitis group, and this finding was closely connected with pain. A number of patients showed cervical lymphadenitis on a CT scan and this coincided with lymph node palpation. Tonsillitis associated sialadenitis was common in the pediatric group. The therapeutic durations were longer in the pediatric parotitis patient group and the adult submandibular sialadenitis group. CT scans were very helpful to evaluate for abscess, stone, lymphadenitis and estimating the associated clinical manifestations such as swelling, palpable lymph nodes, pain with operation and the therapeutic plan