WorldWideScience

Sample records for ct affective attributes

  1. Evolutionary Influences on Attribution and Affect

    Directory of Open Access Journals (Sweden)

    Jennie Brown

    2017-12-01

    Full Text Available Evolutionary theory was applied to Reeder and Brewer's schematic theory and Trafimow's affect theory to extend this area of research with five new predictions involving affect and ability attributions, comparing morality and ability attributions, gender differences, and reaction times for affect and attribution ratings. The design included a 2 (Trait Dimension Type: HR, PR × 2 (Behavior Type: morality, ability × 2 (Valence: positive, negative × 2 (Replication: original, replication × 2 (Sex: female or male actor × 2 (Gender: female or male participant × 2 (Order: attribution portion first, affect portion first mixed design. All factors were within participants except the order and participant gender. Participants were presented with 32 different scenarios in which an actor engaged in a concrete behavior after which they made attributions and rated their affect in response to the behavior. Reaction times were measured during attribution and affect ratings. In general, the findings from the experiment supported the new predictions. Affect was related to attributions for both morality and ability related behaviors. Morality related behaviors received more extreme attribution and affect ratings than ability related behaviors. Female actors received stronger attribution and affect ratings for diagnostic morality behaviors compared to male actors. Male and female actors received similar attribution and affect ratings for diagnostic ability behaviors. Diagnostic behaviors were associated with lower reaction times than non-diagnostic behaviors. These findings demonstrate the utility of evolutionary theory in creating new hypotheses and empirical findings in the domain of attribution.

  2. Correlations of CT and EEG findings in brain affections

    International Nuclear Information System (INIS)

    Roth, B.; Nevsimalova, S.; Kvicala, V.

    1984-01-01

    The results were compared of electroencephalography (EEG) and computerized tomography (CT) examinations of 250 patients with different brain affections. In intracranial expansive processes the pre-operative CT findings were positive in 100% cases, the EEG findings in 89.7% of cases. In severe traumatic affections the EEG and CT findings were positive in all cases, in mild injuries and post-traumatic conditions the EEG findings were more frequently positive than the CT. In focal and diffuse vascular affections the EEG and CT findings were consistent, in transitory ischemic conditions the EEG findings were more frequently positive. In inflammatory cerebral affections and in paroxymal diseases the EEG findings were positive more frequently than the CT. The same applies for demyelinating and degenerative affections. Findings of other authors were confirmed to the effect that CT very reliably reveals morphological changes in cerebral tissue while EEG records the functional state of the central nervous system and its changes. The two methods are complementary. (author)

  3. Attributions of responsibility and affective reactions to decision outcomes.

    Science.gov (United States)

    Zeelenberg, M; van der Pligt, J; de Vries, N K

    2000-06-01

    Immediate affective reactions to outcomes are more intense following decisions to act than following decisions not to act. This finding holds for both positive and negative outcomes. We relate this "actor-effect" to attribution theory and argue that decision makers are seen as more responsible for outcomes when these are the result of a decision to act as compared to a decision not to act. Experiment 1 (N = 80) tests the main assumption underlying our reasoning and shows that affective reactions to decision outcomes are indeed more intense when the decision maker is seen as more responsible. Experiment 2 (N = 40) tests whether the actor effect can be predicted on the basis of differential attributions following action and inaction. Participants read vignettes in which active and passive actors obtained a positive or negative outcome. Action resulted in more intense affect than inaction, and positive outcomes resulted in more intense affect than negative outcomes. Experiment 2 further shows that responsibility attributions and affective reactions to outcomes are highly correlated; that is, more extreme affective reactions are associated with more internal attributions. We discuss the implications for research on post-decisional reactions.

  4. CT-derived indices of canine osteosarcoma-affected antebrachial strength.

    Science.gov (United States)

    Garcia, Tanya C; Steffey, Michele A; Zwingenberger, Allison L; Daniel, Leticia; Stover, Susan M

    2017-05-01

    To improve the prediction of fractures in dogs with bone tumors of the distal radius by identifying computed tomography (CT) indices that correlate with antebrachial bone strength and fracture location. Prospective experimental study. Dogs with antebrachial osteosarcoma (n = 10), and normal cadaver bones (n=9). Antebrachia were imaged with quantitative CT prior to biomechanical testing to failure. CT indices of structural properties were compared to yield force and maximum force using Pearson correlation tests. Straight beam failure (Fs), axial rigidity, curved beam failure (Fc), and craniocaudal bending moment of inertia (MOICrCd) CT indices most highly correlated (0.77 > R > 0.57) with yield and maximum forces when iOSA-affected and control bones were included in the analysis. Considering only OSA-affected bones, Fs, Fc, and axial rigidity correlated highly (0.85 > R > 0.80) with maximum force. In affected bones, the location of minimum axial rigidity and maximum MOICrCd correlated highly (R > 0.85) with the actual fracture location. CT-derived axial rigidity, Fs, and MOICrCd have strong linear relationships with yield and maximum force. These indices should be further evaluated prospectively in OSA-affected dogs that do, and do not, experience pathologic fracture. © 2017 The American College of Veterinary Surgeons.

  5. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

    International Nuclear Information System (INIS)

    Aw-Zoretic, J.; Seth, D.; Katzman, G.; Sammet, S.

    2014-01-01

    Purpose: The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). Method and materials: A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Results: Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10–18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Conclusion: Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed

  6. Do hostile attributions and negative affect explain the association between authoritarian beliefs and harsh parenting?

    Science.gov (United States)

    Crouch, Julie L; Irwin, Lauren M; Milner, Joel S; Skowronski, John J; Rutledge, Ericka; Davila, America L

    2017-05-01

    The present study examined the associations between authoritarian parenting beliefs, attributions of hostile intent, negative affect, and harsh parenting practices. General population parents (N=183; 31.1% fathers) completed self-report measures of authoritarian parenting beliefs and read vignettes describing children engaging in transgressions. Following each vignette, parents indicated the extent to which they would attribute hostile intent to the child, feel negative affect, and respond with harsh parenting practices (e.g., yelling, hitting). As hypothesized, parents who subscribed to higher levels of authoritarian beliefs attributed more hostile intent to the child and expected to feel more negative affect in response to the transgressions. In turn, higher levels of hostile attributions and negative affect were associated with increased likelihood of harsh parenting practices. Results from a path analysis revealed that the association between authoritarian parenting beliefs and harsh parenting practices was fully explained by attributions of hostile intent and negative affect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Storage temperature affects fruit quality attributes of Ber (Ziziphus ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-03

    Sep 3, 2008 ... 2Department of Agricultural Research and Extension Services, Agronomy Research Institute, Box CY 550, Causeway, ... Fruit utilization is affected by quality attributes and shelf life. ... preserve fresh and dried fruits can ensure its availability ... Vitamin C was determined using titrimetric method with 2,6-.

  8. Storage temperature affects fruit quality attributes of Ber ( Ziziphus ...

    African Journals Online (AJOL)

    Fruit utilization is affected by quality attributes and shelf life. The quality of Jujube or Ber (Ziziphus mauritiana Lamk.) fruits after harvest depends on storage conditions used. In this study, different storage temperatures and durations were evaluated to determine the appropriate storage conditions of fresh fruits of Z.

  9. Mechanisms for Promoting the Development of Cognitive, Social and Affective Graduate Attributes

    Science.gov (United States)

    Kember, David; Hong, Celina; Yau, Vickie W. K.; Ho, Shun Amaly

    2017-01-01

    The aim of this study was to help universities promote graduate attributes by investigating mechanisms for promoting the development of cognitive, social and affective attributes which could impact upon all undergraduate students. Small group interviews were conducted with 90 final year students at a university in Hong Kong. Interview transcripts…

  10. Service design attributes affecting diabetic patient preferences of telemedicine in South Korea.

    Science.gov (United States)

    Park, Hayoung; Chon, Yucheong; Lee, Jongsu; Choi, Ie-Jung; Yoon, Kun-Ho

    2011-01-01

    Attempts to introduce telemedicine in South Korea have failed mostly, leaving critical questions for service developers and providers about whether patients would be willing to pay for the service and how the service should be designed to encourage patient buy-in. In this study, we explore patients' valuations and preferences for each attribute of telemedicine service for diabetes management and evaluate patient willingness to pay for specific service attributes. We conducted a conjoint survey to collect data on patients' stated preferences among telemedicine service alternatives. The alternatives for diabetes-related service differed in 10 attributes, including those related to price, type of service provider, and service scope. To estimate the relative importance of attributes, patients' willingness to pay for each attribute, and their probable choice of specific alternatives, we used a rank-ordered logit model. A total of 118 respondents participated in the survey. All 10 attributes significantly affected patients' valuations and preferences, and demographic and disease characteristics, such as existence of complications and comorbidities, significantly affected patients' valuations of the attributes. Price was the most important attribute, followed by comprehensive scope of service, the availability of mobile phone-based delivery, and large general-hospital provided services. The study findings have significant implications for adoption policy and strategy of telemedicine in diabetes management care. Further, the methodology presented in this study can be used to draw knowledge needed to formulate effective policy for adoption of the necessary technology and for the design of services that attract potential beneficiaries.

  11. MRI and CT in alveolar echinococcosis of the liver

    International Nuclear Information System (INIS)

    Duewell, S.; Marincek, B.; Schulthess, G.K. von; Ammann, R.; Zurich Univ.

    1990-01-01

    To compare the value of MRI and CT in evaluating hepatic alveolar echinococcosis a study was conducted on 30 patients. The liver was initially affected in all patients. At the time of examination, 15 patients had undergone partial liver resection. MRI showed no advantage over CT in demonstrating an echinococcal mass lesion. MRI was superior in identifying concomitant pathological changes of the intrahepatic and extrahepatic venous system due to the intrinsic contrast of vascular structures. However, CT was superior in identifying calcifications, an important attribute of the disease. MRI should only be used in imaging alveolar echinococcosis of the liver if diagnostic questions remain open after CT, in particular questions concerning venous pathology. MRI may also be used to replace CT in patients with a contraindication to urographic contrast material. (orig.) [de

  12. Intravenous contrast injection significantly affects bone mineral density measured on CT

    Energy Technology Data Exchange (ETDEWEB)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology and Internal Medicine-Geriatrics, Postbus 85500, Postbox: E.03.511, GA, Utrecht (Netherlands)

    2014-09-05

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  13. Intravenous contrast injection significantly affects bone mineral density measured on CT

    International Nuclear Information System (INIS)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de

    2015-01-01

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  14. Japanese Pupils’ Attribution of their Perceived Mathematics Performance and the Relationships Between their Attribution of Mathematics Performance and their Affective Attitudes Promoted by Different Teaching Methods

    Directory of Open Access Journals (Sweden)

    Tomomi Saeki

    2006-04-01

    Full Text Available This research used a questionnaire survey to explore the relationship between pupils’ attribution of their perceived mathematics performance and their affective attitudes towards mathematics learning as promoted by the different teaching methods they were exposed to in their mathematics classes. Both 5th and 8th graders attributed their success in learning mathematics to effort, although support from the teacher and support at home were also perceived as important factors in their success. The 5th graders and 8th graders overall gave effort-based attributions in the case of failure, while for 5th graders, ability was regarded as being as important as effort, in attributing failure in mathematics learning. Pupils who attributed their success in mathematics learning to effort, support at school and home, preferred teacher explanation and reading a textbook as learning strategies, while those attributing it to their ability preferred Individual work. Where pupils attributed success to luck, this seemed to have a negative effect on their affective attitudes towards mathematics learning as promoted by different teaching methods, while attributing failure to luck seemed to have positive effect. Attributing failure to poor teaching seemed to have a negative effect on their perception of teacher explanation. The relationships between pupil effort or ability based attributions of failure and their preference for different teaching methods were not clear. Adopting various teaching methods in mathematics classes would seem to support pupils who have different attribution styles.

  15. Success/failure condition influences attribution of control, negative affect, and shame among patients with depression in Singapore.

    Science.gov (United States)

    Yeo, Si-Ning; Zainal, Hani; Tang, Catherine S; Tong, Eddie M; Ho, Cyrus S; Ho, Roger C

    2017-08-02

    There remains a paucity of research on control attribution and depression within Asian populations. This study examines: (1) Success/Failure condition as a moderator between depression and negative affect or shame, and (2) differences in control attribution between patients with depression and healthy controls in Singapore. Seventy one patients with depression and 71 healthy controls went through a digit-span memory task where they were randomized into either the Success or Failure condition. Participants in the Success condition had to memorize and recall 5-digit strings, while participants in the Failure condition did the same for 12-digit strings. They then completed self-report measures of negative affect, shame, and attribution of control. One-way ANCOVA was performed to examine task condition as a moderator of association between mental health status and post-task negative affect or shame. Test of simple effects was carried out on significant interactions. Sign test and Mann-Whitney U test were employed to investigate differences in attribution of control. Mental health status and Success/Failure condition had significant effects on reported negative affect and shame. Healthy controls reported less post-task negative affect and shame in the Success than in the Failure condition while patients with depression reported similar levels of post-task negative affect and shame in both conditions. However, these differences were not significant in the test of simple effects. In addition, healthy controls felt a stronger sense of personal control in success than in failure and were more likely to blame external factors in failure than in success. Conversely, patients with depression were more inclined to credit external factors in success than in failure and ascribed greater personal control in failure than in success. The results suggest that successful conditions may not necessitate the reduction of negative affect in Asians with depression, indicating possible

  16. Technical attributes, health attribute, consumer attributes and their roles in adoption intention of healthcare wearable technology.

    Science.gov (United States)

    Zhang, Min; Luo, Meifen; Nie, Rui; Zhang, Yan

    2017-12-01

    This paper aims to explore factors influencing the healthcare wearable technology adoption intention from perspectives of technical attributes (perceived convenience, perceived irreplaceability, perceived credibility and perceived usefulness), health attribute (health belief) and consumer attributes (consumer innovativeness, conspicuous consumption, informational reference group influence and gender difference). By integrating technology acceptance model, health belief model, snob effect and conformity and reference group theory, hypotheses and research model are proposed. The empirical investigation (N=436) collects research data through questionnaire. Results show that the adoption intention of healthcare wearable technology is influenced by technical attributes, health attribute and consumer attributes simultaneously. For technical attributes, perceived convenience and perceived credibility both positively affect perceived usefulness, and perceived usefulness influences adoption intention. The relation between perceived irreplaceability and perceived usefulness is only supported by males. For health attribute, health belief affects perceived usefulness for females. For consumer attributes, conspicuous consumption and informational reference group influence can significantly moderate the relation between perceived usefulness and adoption intention and the relation between consumer innovativeness and adoption intention respectively. What's more, consumer innovativeness significantly affects adoption intention for males. This paper aims to discuss technical attributes, health attribute and consumer attributes and their roles in the adoption intention of healthcare wearable technology. Findings may provide enlightenment to differentiate product developing and marketing strategies and provide some implications for clinical medicine. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. On the universality of the attribution-affect model of helping.

    Science.gov (United States)

    Reisenzein, Rainer

    2015-08-01

    Although Pilati et al.'s (2014) findings question the strong quantitative universality of the attribution-affect model of helping, they are consistent with a weak form of quantitative universality, as well as with the qualitative universality of the theory. However, universality is put into question by previous studies revealing significant and sizeable between-study differences in the strength of the causal paths postulated by the theory. These differences may in part reflect differences in the type of helping situations studied. © 2015 International Union of Psychological Science.

  18. Unemployment and depressive affect: a motivational and attributional analysis.

    Science.gov (United States)

    Feather, N T; Davenport, P R

    1981-09-01

    It was hypothesized on the basis of expectancy-valence theory that the negative affect that follows failure to obtain employment will be stronger among those individuals who are more strongly motivated to seek employment than among those who are less motivated. This hypothesis was tested by administering a questionnaire to a sample of 212 unemployed youth contacted through helping agencies in Adelaide, South Australia. Consistent with the hypothesis, the results showed that subjects who indicated in their ratings that they were highly motivated to get a job also provided higher ratings of depressive affect. Those subjects with higher levels of depressive affect were less likely to blame themselves for their unemployment and more likely to blame external difficulties, such as the current economic situation. They also provided higher ratings of the valence or perceived attractiveness of work itself. Their retrospective ratings concerning how confident they were of getting a job on leaving school and how much they needed and tried for a job also tended to be higher than those of the less depressed subjects. Results are discussed in relation to the expectancy-valence approach, Beck's theory of depression, the helplessness theory of depression, and recent discussions of cognitive-effect linkages that employ attribution concepts.

  19. Attributes affecting campsite selection at two types of campgrounds in the Adirondack Park

    Science.gov (United States)

    Kye-Young Choi; Chad P. Dawson

    2003-01-01

    This study compared the important attributes affecting campers' decisions in selecting their preferred campsites at two different types of New York State Department of Environmental Conservation (NYSDEC) campgrounds in the Adirondack Park. Mail surveys were sent to campers using six NYSDEC campgrounds (three less-developed campgrounds and three more-developed...

  20. Objective factors affecting the image quality of low-dose cranial CT of infant

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Wang Hongwei; Zeng Hongwu; Cao Weiguo; Sun Longwei

    2010-01-01

    Objective: To investigate the objective factors that affect the image quality of infant cranial CT using different mAs. Materials and Methods: Ninety infants were divided into three groups randomly. The maximum anteroposterior diameter (MAPD) of skull of each infant was measured. Three reference levels, cerebellar, basal ganglia and centrum semiovale levels were selected respectively. Only one level was studied in each group and scanned with 150, 100 and 80 mAs. The subjective quality grade and the objective noise of all images were recorded and analysed statistically. Results: The average MAPD of ninety patients was (148.0±17.4) mm. On the cerebellar level, the subjective quality grade was lower than the other two levels, which were 6.3%, 9.4% and 22.9% respectively when mAs were 150, 100 and 80 mAs. Both quality grade of image and objective noise were significantly correlated with MAPD. Conclusions: The inherent high noise of cerebellar level and MAPD were the objective factors that affect the image quality of low-dose cranial CT of infant. (authors)

  1. Caffeic acid phenethyl ester preferentially sensitizes CT26 colorectal adenocarcinoma to ionizing radiation without affecting bone marrow radioresponse

    International Nuclear Information System (INIS)

    Chen, Y.-J.; Liao, H.-F.; Tsai, T.-H.; Wang, S.-Y.; Shiao, M.-S.

    2005-01-01

    Purpose: Caffeic acid phenethyl ester (CAPE), a component of propolis, was reported capable of depleting glutathione (GSH). We subsequently examined the radiosensitizing effect of CAPE and its toxicity. Methods and Materials: The effects of CAPE on GSH level, GSH metabolism enzyme activities, NF-κB activity, and radiosensitivity in mouse CT26 colorectal adenocarcinoma cells were determined. BALB/c mouse with CT26 cells implantation was used as a syngeneic in vivo model for evaluation of treatment and toxicity end points. Results: CAPE entered CT26 cells rapidly and depleted intracellular GSH in CT26 cells, but not in bone marrow cells. Pretreatment with nontoxic doses of CAPE significantly enhanced cell killing by ionizing radiation (IR) with sensitizer enhancement ratios up to 2.2. Pretreatment of CT26 cells with N-acetyl-L-cysteine reversed the GSH depletion activity and partially blocked the radiosensitizing effect of CAPE. CAPE treatment in CT26 cells increased glutathione peroxidase, decreased glutathione reductase, and did not affect glutathione S-transferase or γ-glutamyl transpeptidase activity. Radiation activated NF-κB was reversed by CAPE pretreatment. In vivo study revealed that pretreatment with CAPE before IR resulted in greater inhibition of tumor growth and prolongation of survival in comparison with IR alone. Pretreatment with CAPE neither affected body weights nor produced hepatic, renal, or hematopoietic toxicity. Conclusions: CAPE sensitizes CT26 colorectal adenocarcinoma to IR, which may be via depleting GSH and inhibiting NF-κB activity, without toxicity to bone marrow, liver, and kidney

  2. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kornerup, Josefine S.; Munck af Rosenschoeld, Per [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); The Niels Bohr Institute, Faculty of Science, University of Copenhagen, Copenhagen (Denmark); Brodin, Patrik [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); Institute for Onco-Physics, Albert Einstein College of Medicine of Yeshiva University, Bronx, NY (United States); Birk Christensen, Charlotte; Borgwardt, Lise [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Bjoerk-Eriksson, Thomas [Sahlgrenska University Hospital, Department of Oncology, Gothenburg (Sweden); Kiil-Berthelsen, Anne [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-04-01

    PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning. The risk of inducing secondary cancer was estimated using the models in BEIR VII. The prognosis of an induced cancer was taken into account and the reduction in life expectancy, in terms of life years lost, was estimated for the diagnostics and compared to the life years lost attributable to the therapy. Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost attributable to the nuclear medicine dose component from one PET/CT scan was 15% (range: 3-41%). The ratio of life years lost from the radiation therapy planning PET/CT scans and that of the cancer treatment was on average 0.02 (range: 0.01-0.09). Female gender was associated with increased life years lost from the scans (P < 0.001). Using FDG-PET/CT instead of CT only when defining the target volumes for radiation therapy of children with cancer does not notably increase the number of life years lost attributable to diagnostic examinations. (orig.)

  3. Extending Attribution Theory: Considering Students' Perceived Control of the Attribution Process

    Science.gov (United States)

    Fishman, Evan J.; Husman, Jenefer

    2017-01-01

    Research in attribution theory has shown that students' causal thinking profoundly affects their learning and motivational outcomes. Very few studies, however, have explored how students' attribution-related beliefs influence the causal thought process. The present study used the perceived control of the attribution process (PCAP) model to examine…

  4. Enriching a primary health care version of ICD-10 using SNOMED CT mapping

    Directory of Open Access Journals (Sweden)

    Nyström Mikael

    2010-06-01

    Full Text Available Abstract Background In order to satisfy different needs, medical terminology systems must have richer structures. This study examines whether a Swedish primary health care version of the mono-hierarchical ICD-10 (KSH97-P may obtain a richer structure using category and chapter mappings from KSH97-P to SNOMED CT and SNOMED CT's structure. Manually-built mappings from KSH97-P's categories and chapters to SNOMED CT's concepts are used as a starting point. Results The mappings are manually evaluated using computer-produced information and a small number of mappings are updated. A new and poly-hierarchical chapter division of KSH97-P's categories has been created using the category and chapter mappings and SNOMED CT's generic structure. In the new chapter division, most categories are included in their original chapters. A considerable number of concepts are included in other chapters than their original chapters. Most of these inclusions can be explained by ICD-10's design. KSH97-P's categories are also extended with attributes using the category mappings and SNOMED CT's defining attribute relationships. About three-fourths of all concepts receive an attribute of type Finding site and about half of all concepts receive an attribute of type Associated morphology. Other types of attributes are less common. Conclusions It is possible to use mappings from KSH97-P to SNOMED CT and SNOMED CT's structure to enrich KSH97-P's mono-hierarchical structure with a poly-hierarchical chapter division and attributes of type Finding site and Associated morphology. The final mappings are available as additional files for this paper.

  5. DXD Motif-Dependent and -Independent Effects of the Chlamydia trachomatis Cytotoxin CT166

    Directory of Open Access Journals (Sweden)

    Miriam Bothe

    2015-02-01

    Full Text Available The Gram-negative, intracellular bacterium Chlamydia trachomatis causes acute and chronic urogenital tract infection, potentially leading to infertility and ectopic pregnancy. The only partially characterized cytotoxin CT166 of serovar D exhibits a DXD motif, which is important for the enzymatic activity of many bacterial and mammalian type A glycosyltransferases, leading to the hypothesis that CT166 possess glycosyltransferase activity. CT166-expressing HeLa cells exhibit actin reorganization, including cell rounding, which has been attributed to the inhibition of the Rho-GTPases Rac/Cdc42. Exploiting the glycosylation-sensitive Ras(27H5 antibody, we here show that CT166 induces an epitope change in Ras, resulting in inhibited ERK and PI3K signaling and delayed cell cycle progression. Consistent with the hypothesis that these effects strictly depend on the DXD motif, CT166 with the mutated DXD motif causes neither Ras-ERK inhibition nor delayed cell cycle progression. In contrast, CT166 with the mutated DXD motif is still capable of inhibiting cell migration, suggesting that CT166 with the mutated DXD motif cannot be regarded as inactive in any case. Taken together, CT166 affects various fundamental cellular processes, strongly suggesting its importance for the intracellular survival of chlamydia.

  6. Estimated risk of radiation-induced cancer from paediatric chest CT: two-year cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Tilo [Cantonal Hospital Baden, Department of Radiology, Baden (Switzerland); University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Colas, Lucie; Santangelo, Teresa; Faivre, Jean Baptiste; Remy, Jacques; Remy-Jardin, Martine [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Roser, Hans W.; Bremerich, Jens [University of Basel Hospital, Clinic of Radiology and Nuclear Medicine, Medical Physics, Basel (Switzerland)

    2015-03-01

    The increasing absolute number of paediatric CT scans raises concern about the safety and efficacy and the effects of consecutive diagnostic ionising radiation. To demonstrate a method to evaluate the lifetime attributable risk of cancer incidence/mortality due to a single low-dose helical chest CT in a two-year patient cohort. A two-year cohort of 522 paediatric helical chest CT scans acquired using a dedicated low-dose protocol were analysed retrospectively. Patient-specific estimations of radiation doses were modelled using three different mathematical phantoms. Per-organ attributable cancer risk was then estimated using epidemiological models. Additional comparison was provided for naturally occurring risks. Total lifetime attributable risk of cancer incidence remains low for all age and sex categories, being highest in female neonates (0.34%). Summation of all cancer sites analysed raised the relative lifetime attributable risk of organ cancer incidence up to 3.6% in female neonates and 2.1% in male neonates. Using dedicated scan protocols, total lifetime attributable risk of cancer incidence and mortality for chest CT is estimated low for paediatric chest CT, being highest for female neonates. (orig.)

  7. Productivity losses attributable to untreated chlamydial infection and associated pelvic inflammatory disease in reproductive-aged women.

    Science.gov (United States)

    Blandford, John M; Gift, Thomas L

    2006-10-01

    The productivity losses attributable to disease-related morbidity and mortality impose a burden on society in general and on employers in particular. A reliable assessment of the productivity losses associated with untreated infection with Chlamydia trachomatis (Ct) would complement earlier work on direct medical costs and contribute to an estimate of the full cost of chlamydial disease. The goal of this study was to estimate the discounted lifetime productivity losses attributable to untreated chlamydial infection in reproductive-aged women. We developed a cost model using Monte Carlo methods to estimate the lifetime discounted productivity losses attributable to untreated lower genital tract Ct infection among reproductive-aged women. The model considered the impact of disability resulting from acute pelvic inflammatory disease (PID) associated with untreated Ct infection and from the sequelae of acute PID, including chronic pelvic pain, ectopic pregnancy, and infertility. To accommodate disparate Ct infection rates and labor market characteristics across age groups, we matched age-based risk factors for Ct infection with labor market patterns. Data sources included the 2001 National Chlamydia Surveillance Data, the 2001 Current Population Survey, and published literature. Estimates indicate that the mean weighted productivity losses per untreated Ct infection were approximately US dollars 130 (in year 2001 dollars). Mean weighted productivity losses per case of acute PID were estimated at US dollars 649. Estimated productivity losses were highly correlated with age, reflecting age-dependent differences in labor market characteristics. The productivity losses attributable to untreated infection with Ct and to sequelae of this infection form a substantial portion of the total economic burden of disease. Effective programs to prevent chlamydial infection and effective screening, diagnosis, and treatment of Ct-infected women may reduce productivity losses and

  8. Radiation risk and protection of patients in clinical SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Borowski, Markus [Klinikum Braunschweig, Institute of Radiation Diagnostics and Nuclear Medicine, Braunschweig (Germany)

    2014-05-15

    Clinical studies have demonstrated that hybrid single photon emission computed tomography (SPECT)/CT for various diagnostic issues has an added value as compared to SPECT alone. However, the combined acquisition of functional and anatomical images can substantially increase radiation exposure to patients, in particular when using a hybrid system with diagnostic CT capabilities. It is, therefore, essential to carefully balance the diagnostic needs and radiation protection requirements. To this end, the evidence on health effects induced by ionizing radiation is outlined. In addition, the essential concepts for estimating radiation doses and lifetime attributable cancer risks associated with SPECT/CT examinations are presented taking into account both the new recommendations of the International Commission on Radiological Protection (ICRP) as well as the most recent radiation risk models. Representative values of effective dose and lifetime attributable risk are reported for ten frequently used SPECT radiopharmaceuticals and five fully diagnostic partial-body CT examinations. A diagnostic CT scan acquired as part of a combined SPECT/CT examination contributes considerably to, and for some applications even dominates, the total patient exposure. For the common SPECT and CT examinations considered in this study, the lifetime attributable risk of developing a radiation-related cancer is less than 0.27 %/0.37 % for men/women older than 16 years, respectively, and decreases markedly with increasing age at exposure. Since there is no clinical indication for a SPECT/CT examination unless an emission scan has been indicated, the issue on justification comes down to the question of whether it is necessary to additionally acquire a low-dose CT for attenuation correction and anatomical localization of tracer uptake or even a fully diagnostic CT. In any case, SPECT/CT studies have to be optimized, e.g. by adapting dose reduction measures from state-of-the-art CT practice, and

  9. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer

    DEFF Research Database (Denmark)

    Kornerup, Josefine S.; Brodin, Nils Patrik; Christensen, Charlotte Birk

    2015-01-01

    BACKGROUND: PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. OBJECTIVE: To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans...... used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. MATERIALS AND METHODS: Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning....... Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. RESULTS: The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost...

  10. CT of the pulmonary ligament

    International Nuclear Information System (INIS)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-01-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures

  11. CT of the pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-08-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures.

  12. Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia

    International Nuclear Information System (INIS)

    Moorin, Rachael E; Forsyth, Rene; Gibson, David J; Fox, Richard

    2013-01-01

    Technical data on local CT practice in Western Australia were collected for five major CT providers using a self-completed questionnaire. The CTDIvol DLP and effective dose for each protocol were obtained and providers were ranked according to radiation burden for each clinical scenario. The mean, median, 75th percentile and standard deviation were calculated for both effective dose and DLP for each scenario and these values were compared with published data. CT utilisation data were used to estimate the attributable radiation dose to the WA population and the potential change in population annual effective dose according to the protocol used was estimated. We found that wide variations in technique and radiation dose exist across providers for similar examinations, producing a higher radiation burden than reported internationally. As expected, the CT protocol used dramatically affects the radiation dose received, and this has a significant effect on annual population dose. This study highlights the need for recognition and understanding of both the degree of variation in radiation dose across providers and the relatively high radiation burden afforded by protocols in use in Western Australia so that necessary dialogue can be launched for practitioner consensus on appropriate diagnostic reference levels in CT scanning. (paper)

  13. Kinetics, biocompounds, antioxidant activity, and sensory attributes of quinces as affected by drying method.

    Science.gov (United States)

    Szychowski, Przemysław J; Lech, Krzysztof; Sendra-Nadal, Esther; Hernández, Francisca; Figiel, Adam; Wojdyło, Aneta; Carbonell-Barrachina, Ángel A

    2018-07-30

    Quinces are attracting interest due to their health and nutritional benefits. Drying kinetics, bioactive compounds, antioxidant activity, and the main sensory parameters were determined in dried quinces, cultivar Leskovač, as affected by the drying method. The highest total polyphenols content was observed in dried samples obtained after freeze drying and convective drying at 50 °C. The best drying treatment, considering only sensory attributes, was vacuum-microwave drying at 480 W, because it led to intermediate dark color and high intensities of basic tastes and key flavor attributes. The studied parameters were finally used to recommend convective drying at 60 °C as the most appropriate drying method for quinces, because it had a high content of total phenolic compounds (2nd best treatment out of 10), a good sensory profile, was cheap, and caused no negative effects on nutritional or sensory parameters; the only disadvantage was its long drying time. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. High affective risk perception is associated with more lung cancer-specific distress in CT screening for lung cancer

    NARCIS (Netherlands)

    Bunge, Eveline M.; van den Bergh, Karien A. M.; Essink-Bot, Marie-Louise; van Klaveren, Rob J.; de Koning, Harry J.

    2008-01-01

    Screening for cancer can cause distress. People who perceive their risk of cancer as high may be more vulnerable to distress. This study evaluated whether participants of a lung cancer Computed Tomography (CT) screening trial with a high affective risk perception of developing lung cancer had a

  15. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    Science.gov (United States)

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  16. Crisis Workers' Attributions for Domestic Violence.

    Science.gov (United States)

    Madden, Margaret E.

    Attributions affect coping with victimization. Battered women who blame their husbands' moods are less likely to leave than are women who blame their husbands' permanent characteristics for the violence. Abused women often have repeated contacts with crisis intervention workers and the attitudes of those workers may affect the attributions made by…

  17. Changing US Attributes After CS-US Pairings Changes CS-Attribute-Assessments: Evidence for CS-US Associations in Attribute Conditioning.

    Science.gov (United States)

    Förderer, Sabine; Unkelbach, Christian

    2016-03-01

    Attribute Conditioning (AC) refers to people's changed assessments of stimuli's (CSs) attributes due to repeated pairing with stimuli (USs) possessing these attributes; for example, when an athletic person (US) is paired with a neutral person (CS), the neutral person is judged to be more athletic after the pairing. We hypothesize that this AC effect is due to CSs' associations with USs rather than direct associations with attributes. Three experiments test this hypothesis by changing US attributes after CS-US pairings. Experiments 1 and 2 conditioned athleticism by pairing neutral men (CSs) with athletic and non-athletic USs. Post-conditioning, USs' athleticism was reversed, which systematically influenced participants' assessment of CS athleticism. Experiment 3 conditioned athleticism and changed USs' musicality after CS-US pairings. This post-conditioning change affected musicality assessments of CSs but did not influence athleticism-assessments. The results indicate that AC effects are based on an associative CS-US-attribute structure. © 2016 by the Society for Personality and Social Psychology, Inc.

  18. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  19. Parental Health Attributions of Childhood Health and Illness: Development of the Pediatric Cultural Health Attributions Questionnaire (Pedi-CHAQ).

    Science.gov (United States)

    Vaughn, Lisa M; McLinden, Daniel J; Shellmer, Diana; Baker, Raymond C

    2011-01-01

    The causes attributed to childhood health and illness across cultures (cultural health attributions) are key factors that are now more frequently identified as affecting the health outcomes of children. Research suggests that the causes attributed to an event such as illness are thought to affect subsequent motivation, emotional response, decision making, and behavior. To date, there is no measure of health attributions appropriate for use with parents of pediatric patients. Using the Many-Facets approach to Rasch analysis, this study assesses the psychometrics of a newly developed instrument, the Pediatric Health Attributions Questionnaire (Pedi-CHAQ), a measure designed to assess the cultural health attributions of parents in diverse communities. Results suggest acceptable Rasch model statistics of fit and reliability for the Pedi-CHAQ. A shortened version of the questionnaire was developed as a result of this study and next steps are discussed.

  20. Negative predictive value of 124I-PET/CT imaging in patients affected by metastatic thyroid cancer and treated with 131I

    International Nuclear Information System (INIS)

    Pettinato, C.; Civollani, S.; Nanni, C.; Celli, M.; Allegri, V.; Zagni, P.; Fanti, S.; Monari, F.; Cima, S.; Mazzarotto, R.; Spezi, E.

    2015-01-01

    Full text of publication follows. Aim: patients affected by metastatic Differentiated Thyroid Cancer (mDTC) are treated with 131 I even in presence of negative diagnostic 131 I whole body (WB) scan. Actually, very often, these patients present positive post therapy 131 I whole body scan, showing iodine avid metastases that were not seen with the diagnostic imaging. The aim of this work was the evaluation of the feasibility to use 124 I PET/CT images to predict patients who will not benefit from the iodine therapy, because of the absence of avidity, avoiding useless treatments. Material and methods: 25 patients affected by mDTC were enrolled in the study approved by the ethical Committee of our Institution, with the aim to evaluate the usefulness of 124 I PET/CT sequential scans to predict absorbed doses to metastatic thyroid cancer patients undergoing 131 I therapy. Patients (pts) were divided into 4 groups, based on their histology: group A, 4 pts with follicular cancer; group B, 13 pts with papillary cancer; group C, 2 pts with papillary tall cells cancer; group D, 6 patients with papillary cancer with follicular variant. Patients showing negative 124 I-PET/CT were treated with a reduced dose of 131 I (3700 MBq) and post treatment WB scans were acquired 96 hours after the therapeutic administration. Results: 12 patients showed at least one metastatic lesion at 124 I PET/CT imaging, and most of the lesions were visible at the 24 hours scan (4 pts group A, 3 pts group B, 5 pts group D). The remaining 13 patients did not show any uptake of all known metastatic lesions at each PET/CT time points (10 pts group B, 2 pts group C, 1 pt group D). Negative PET/CT findings were confirmed by post therapy WB scan. Discussion and Conclusion: 124 I-PET/CT scan is a useful diagnostic tool to discriminate patients with iodine avid metastases. Actually, when they are present, the superiority of PET/CT resolution and sensitivity, compared to standard 131 I planar imaging, allow the

  1. Auditing SNOMED CT hierarchical relations based on lexical features of concepts in non-lattice subgraphs.

    Science.gov (United States)

    Cui, Licong; Bodenreider, Olivier; Shi, Jay; Zhang, Guo-Qiang

    2018-02-01

    We introduce a structural-lexical approach for auditing SNOMED CT using a combination of non-lattice subgraphs of the underlying hierarchical relations and enriched lexical attributes of fully specified concept names. Our goal is to develop a scalable and effective approach that automatically identifies missing hierarchical IS-A relations. Our approach involves 3 stages. In stage 1, all non-lattice subgraphs of SNOMED CT's IS-A hierarchical relations are extracted. In stage 2, lexical attributes of fully-specified concept names in such non-lattice subgraphs are extracted. For each concept in a non-lattice subgraph, we enrich its set of attributes with attributes from its ancestor concepts within the non-lattice subgraph. In stage 3, subset inclusion relations between the lexical attribute sets of each pair of concepts in each non-lattice subgraph are compared to existing IS-A relations in SNOMED CT. For concept pairs within each non-lattice subgraph, if a subset relation is identified but an IS-A relation is not present in SNOMED CT IS-A transitive closure, then a missing IS-A relation is reported. The September 2017 release of SNOMED CT (US edition) was used in this investigation. A total of 14,380 non-lattice subgraphs were extracted, from which we suggested a total of 41,357 missing IS-A relations. For evaluation purposes, 200 non-lattice subgraphs were randomly selected from 996 smaller subgraphs (of size 4, 5, or 6) within the "Clinical Finding" and "Procedure" sub-hierarchies. Two domain experts confirmed 185 (among 223) suggested missing IS-A relations, a precision of 82.96%. Our results demonstrate that analyzing the lexical features of concepts in non-lattice subgraphs is an effective approach for auditing SNOMED CT. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Organizational Attributes, Market Growth, and Product Innovation

    NARCIS (Netherlands)

    Song, Michael; Chen, Yan

    2014-01-01

    Extensive research has shown that organizational attributes affect product innovation. Extending this literature, this article delimits two general categories of organizational attributes and relates them to product innovation. Organizational attributes can be either control oriented or flexibility

  3. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  4. Attributing illness to food

    DEFF Research Database (Denmark)

    Batz, M. B.; Doyle, M. P.; Morris, J. G.

    2005-01-01

    source responsible for illness. A wide variety of food attribution approaches and data are used around the world including the analysis of outbreak data, case-control studies, microbial subtyping and source tracking methods, and expert judgment, among others. The Food Safety Research Consortium sponsored......Identification and prioritization of effective food safety interventions require an understanding of the relationship between food and pathogen from farm to consumption. Critical to this cause is food attribution, the capacity to attribute cases of foodborne disease to the food vehicle or other...... the Food Attribution Data Workshop in October 2003 to discuss the virtues and limitations of these approaches and to identify future options for collecting food attribution data in the United States. We summarize workshop discussions and identify challenges that affect progress in this critical component...

  5. Usefulness of low-dose CT in the detection of pulmonary metastasis of gestational trophoblastic tumours

    International Nuclear Information System (INIS)

    Xu, X.J.; Lou, F.L.; Zhang, M.M.; Pan, Z.M.; Zhang, L.

    2007-01-01

    Aim: To determine whether a low-dose spiral chest computed tomography (CT) examination could replace standard-dose chest CT in detecting pulmonary metastases in patients with gestational trophoblastic tumour (GTT). Materials and methods: In a prospective investigation, 67 chest CT examinations of 39 GTT patients were undertaken. All the patients underwent CT examinations using standard-dose (150 mAs, pitch 1, standard reconstruction algorithm) and low-dose (40 mAs, pitch 2, bone reconstruction algorithm) protocols. Two radiologists interpreted images independently. A metastasis was defined as a nodule within lung parenchyma that could not be attributed to a pulmonary vessel. The number of metastases detected with each protocol was recorded. The size of each lesion was measured and categorized as <5, 5-9.9, and ≥10 mm. Wilcoxon's signed rank test was used to assess the difference between the numbers of lesion detected by the two protocols. Results: The CT dose index (CTDI) for the standard-dose and low-dose CT protocols was 10.4 mGy and 1.4 mGy, respectively. One thousand, six hundred, and eighty-two metastases were detected by standard-dose CT, and 1460 lesions by the low-dose protocol. The numbers detected by low-dose CT were significantly less than those detected by standard-dose CT (Z = -3.776, p < 0.001), especially for nodules smaller than 5 mm (Z = -4.167, p < 0.001). However, the disease staging and risk score of the patients were not affected by use of the low-dose protocol. Conclusion: Low-dose chest CT can be used as a staging and follow-up procedure for patients with GTT

  6. Sentinel lymph node mapping using SPECT/CT and gamma probe in endometrial cancer: an analysis of parameters affecting detection rate

    Energy Technology Data Exchange (ETDEWEB)

    Sahbai, Samine; La Fougere, Christian; Dittmann, Helmut [University Hospital Tuebingen, Nuclear Medicine and Clinical Molecular Imaging, Tuebingen (Germany); Taran, Florin-Andrei; Wallwiener, Diethelm; Brucker, Sara [University Hospital Tuebingen, Gynecology and Obstetrics, Tuebingen (Germany); Staebler, Annette [University Hospital Tuebingen, Pathology, Tuebingen (Germany)

    2017-08-15

    SPECT/CT after pericervical injection of technetium-99 m-nanocolloid was shown to be suitable for sentinel lymph node (SLN) mapping in endometrial cancer (EC). The aim of this study was to analyze factors affecting successful SLN detection by means of SPECT/CT such as imaging findings, patient characteristics and tumor biology in a large cohort of patients. One hundred and forty-five consecutive patients suffering from EC who received pre-surgical SLN mapping at our institution between 2011 and 2016 were included in this analysis. SPECT/CT data of abdomen and pelvis (mean 4:20 ± 1:20 h p.i.) were acquired after pericervical injection of technetium-99 m-nanocolloid (mean 230 ± 45 MBq) in all patients. Surgical staging was performed on the day after. Acquisition parameters, patient characteristics, SPECT/CT findings as well as histopathological results were collected. A total of 282 SLNs were identified by means of SPECT/CT. Overall, preoperative and intraoperative SLN detection rates were 86%, 76% and 74% respectively. The most important factor associated with failure to detect SLNs was the presence of high bone marrow on SPECT/CT (p = 0.005). Peritoneal/abdominal radioactivity was also associated with missed SLN detection in SPECT/CT (p = 0.02). However, the presence of liver/spleen uptake on its own was not predictive for detection failure. Low numbers of detected SLNs in SPECT/CT were slightly related with older age and lower injected activity. No significant influence was found for the parameters of tumor histology and stage, lymph node involvement and the time gap between injection and imaging. Venous drainage as indicated by bone marrow uptake is the most important factor associated with scintigraphic SLN detection failure. Moreover, high peritoneal and abdominal activity was also associated with detection failure. Thus, meticulous application of the radiotracer is crucial in EC. (orig.)

  7. Chemical and biological attributes of a lowland soil affected by land leveling

    Directory of Open Access Journals (Sweden)

    José Maria Barbat Parfitt

    2013-11-01

    Full Text Available The objective of this work was to evaluate the relationship between soil chemical and biological attributes and the magnitude of cuts and fills after the land leveling process of a lowland soil. Soil samples were collected from the 0 - 0.20 m layer, before and after leveling, on a 100 point grid established in the experimental area, to evaluate chemical attributes and soil microbial biomass carbon (MBC. Leveling operations altered the magnitude of soil chemical and biological attributes. Values of Ca, Mg, S, cation exchange capacity, Mn, P, Zn, and soil organic matter (SOM decreased in the soil profile, whereas Al, K, and MBC increased after leveling. Land leveling decreased in 20% SOM average content in the 0 - 0.20 m layer. The great majority of the chemical attributes did not show relations between their values and the magnitude of cuts and fills. The relation was quadratic for SOM, P, and total N, and was linear for K, showing a positive slope and indicating increase in the magnitude of these attributes in cut areas and stability in fill areas. The relationships between these chemical attributes and the magnitude of cuts and fills indicate that the land leveling map may be a useful tool for degraded soil recuperation through amendments and organic fertilizers.

  8. Patient doses from CT examinations in the United Arab Emirates

    International Nuclear Information System (INIS)

    Janeczek, J.

    2006-01-01

    Full text of publication follows: The main goal of the study was to estimate effective patient doses from the 6 most common CT examinations for different types of CT scanners within the United Arab Emirates. The results were used to assess future trends in patient CT doses following rapid replacement of axial and single-slice spiral scanners by multi-slice scanners. At present all three types of scanner technology exist: axial, spiral and multi-slice with axial scanners being gradually replaced by multi-slice scanners as the medical infrastructure of the country is modernized. Altogether there are more than 30 CT scanners in the country with a population of 4 million. Out of these 11 scanners are 16-slice models with tube-current modulation system. The majority of larger United Arab Emirates hospitals have at least two CT scanners: a single slice and 4 or 16-slice scanner. The survey was carried out with data collection forms distributed to the majority of CT scanner users in the United Arab Emirates hospitals, both private and government. Effective doses for different examinations were calculated from T.L.D. measurements using an Alderson Rando phantom simulating an average size patient. Our results show that effective doses to patients initially increased with the introduction of 4-slice scanners. Multi-slice scanners with 16 and more slices have tube-current modulation system as a standard. It is routinely used by radiographers in almost all examinations resulting in patient dose reduction up to 40 % in certain examinations. Another factor affecting population dose is the increased number of patients examined using multi-slice scanners. In the United Arab Emirates there was an increase of more than 30 % in the annual number of patients examined using multi-slice scanners in comparison to single-slice scanners. This fact is attributed to the ease and speed of operation of multi-slice scanners. Rapid increase in number of CT examinations is of concern. Medical

  9. Analytical similarity assessment of rituximab biosimilar CT-P10 to reference medicinal product.

    Science.gov (United States)

    Lee, Kyoung Hoon; Lee, Jihun; Bae, Jin Soo; Kim, Yeon Jung; Kang, Hyun Ah; Kim, Sung Hwan; Lee, So Jung; Lim, Ki Jung; Lee, Jung Woo; Jung, Soon Kwan; Chang, Shin Jae

    2018-04-01

    CT-P10 (Truxima™) was recently approved as the world's first rituximab biosimilar product in the European Union (EU) and South Korea. To demonstrate biosimilarity of CT-P10 with the reference medicinal product (RMP), extensive 3-way similarity assessment has been conducted between CT-P10, EU-Rituximab and US-Rituximab, focusing on the physicochemical and biological quality attributes. A multitude of state-of-the-art analyses revealed that CT-P10 has identical primary and higher order structures compared to the original product. Purity/impurity profiles of CT-P10 measured by the levels of aggregates, fragments, non-glycosylated form and process-related impurities were also found to be comparable with those of RMPs. In terms of the post-translational modification, CT-P10 contains slightly less N-terminal pyro-glutamate variant, which has been known not to affect product efficacy or safety. Oligosaccharide profiling has revealed that, although CT-P10 contains the same conserved glycan species and relative proportion with the RMPs, the content of total afucosylated glycan in CT-P10 was slightly higher than in EU- or US-Rituximab. Nevertheless, the effect of the observed level of afucosylation in CT-P10 drug product on Fc receptor binding affinity or antibody-dependent cell-mediated cytotoxicity was found to be negligible based on the spiking study with highly afucosylated sample. Arrays of biological assays representative of known and putative mechanisms of action for rituximab have shown that biological activities of CT-P10 are within the quality range of RMPs. Recent results of clinical studies have further confirmed that the CT-P10 exhibits equivalent clinical efficacy and safety profiles compared to EU- and US-Rituximab. The current 3-way similarity assessment together with clinical study results confidently demonstrate that CT-P10 is highly similar with EU- and US-Rituximab in terms of physicochemical properties, biological activities, efficacy, and safety for

  10. Role of {sup 18F} FDG PET/CT, {sup 123I} MIBG SPECT, and CT in Restaging patients Affected by Malignant Pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Cantalamessa, Antonio; Caobelli, Antonio; Vavassori, Francesca [Habilita Istituto Clinico, Bergamo (Italy); Caobelli, Federico [Univ. of Brescia, Brescia (Italy); Paghera, Barbara [Spedali Civili, Brescia (Italy)

    2011-06-15

    Pheochromocytoma (PH) is a rare catecholamine secreting tumor that arises from chromaffin tissue within the adrenal medulla and extra adrenal sites; commonly it is sporadic, and malignant PH accounts for about 10% of all cases. Several imaging modalities have been used for the diagnosis and staging og this tumor: functional imaging using radio labelled metaiodobenzylguanidine and, more recently, {sup 18F} fluorodeoxyglucose positron emission tomography ({sup 18F} FDG PET/CT), which offers substantial sensitivity and specificity to correctly detect metastatic PH and helps to identify patients suitable for treatment with radiopharmaceuticals. The aim of our study was to compare CT, {sup 18F} FDG PET/CT, and {sup 123I} metaiodobenzylguanidine single photon emission tomography ({sup 123I} MIBG SPECT) as feasible methods to restage patients diagnosed histologically with PH. We retrospectively evaluated 38 patients (27 females and 11 males; mean age: 44{+-}15 years) with malignant PH documented histologically after surgical intervention. These patients underwent CT, {sup 18F} FDG PET/CT, and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT showed positive results for neoplastic tissue in 33/38 patients (86.8%) and negative in 5/38 (13.2%), in concordance with CT alone. {sup 123I} MIBG SPECT was positive in 30/38 patients (78.9%) and negative in 8/38 (21.1%). No differences in lesion numbers were found between {sup 18F} FDG PET/CT and {sup 123I} MIBG SPECT. {sup 18F} FDG PET/CT could more accurately restage patients with PH than CT and {sup 123I} MIBG SPECT, also in the absence of a staging study.

  11. COBE: A Conjunctive Ontology Browser and Explorer for Visualizing SNOMED CT Fragments.

    Science.gov (United States)

    Sun, Mengmeng; Zhu, Wei; Tao, Shiqiang; Cui, Licong; Zhang, Guo-Qiang

    2015-01-01

    Ontology search interfaces can benefit from the latest information retrieval advances. This paper introduces a Conjunctive Ontology Browser and Explorer (COBE) for searching and exploring SNOMED CT concepts and visualizing SNOMED CT fragments. COBE combines navigational exploration (NE) with direct lookup (DL) as two complementary modes for finding specific SNOMED CT concepts. The NE mode allows a user to interactively and incrementally narrow down (hence conjunctive) the search space by adding word stems, one at a time. Such word stems serve as attribute constraints, or "attributes" in Formal Concept Analysis, which allows the user to navigate to specific SNOMED CT concept clusters. The DL mode represents the common search mechanism by using a collection of key words, as well as concept identifiers. With respect to the DL mode, evaluation against manually created reference standard showed that COBE attains an example-based precision of 0.958, recall of 0.917, and F1 measure of 0.875. With respect to the NE mode, COBE leverages 28,371 concepts in non-lattice fragments to construct the stem cloud. With merely 9.37% of the total SNOMED CT stem cloud, our navigational exploration mode covers 98.97% of the entire concept collection.

  12. Attribute-Based Signcryption: Signer Privacy, Strong Unforgeability and IND-CCA Security in Adaptive-Predicates Model (Extended Version

    Directory of Open Access Journals (Sweden)

    Tapas Pandit

    2016-08-01

    Full Text Available Attribute-Based Signcryption (ABSC is a natural extension of Attribute-Based Encryption (ABE and Attribute-Based Signature (ABS, where one can have the message confidentiality and authenticity together. Since the signer privacy is captured in security of ABS, it is quite natural to expect that the signer privacy will also be preserved in ABSC. In this paper, first we propose an ABSC scheme which is weak existential unforgeable and IND-CCA secure in adaptive-predicates models and, achieves signer privacy. Then, by applying strongly unforgeable one-time signature (OTS, the above scheme is lifted to an ABSC scheme to attain strong existential unforgeability in adaptive-predicates model. Both the ABSC schemes are constructed on common setup, i.e the public parameters and key are same for both the encryption and signature modules. Our first construction is in the flavor of CtE&S paradigm, except one extra component that will be computed using both signature components and ciphertext components. The second proposed construction follows a new paradigm (extension of CtE&S , we call it “Commit then Encrypt and Sign then Sign” (CtE&S . The last signature is generated using a strong OTS scheme. Since, the non-repudiation is achieved by CtE&S paradigm, our systems also achieve the same.

  13. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  14. Estimating cancer risks induced by CT screening for Korea population

    International Nuclear Information System (INIS)

    Yang, Hye Jeong; Yang, Won Seok

    2016-01-01

    Computed Tomography(CT) has been used to diagnose early stages of cancer and other diseases. Since the number of CT screening has been increasing, there is now a debate about the possible benefits and risks of CT screening on asymptomatic individuals. CT screening has definite benefits, however the radiation risk of screening an asymptomatic individual is a serious problem that cannot be overlooked. Despite its potential risks, CT screening for asymptomatic individual has been gradually increased in Korea and it is attributed to increase collective effective dose. Therefore, we reported the risk level of each organ which is included in scan field for CT screening and analyzed and then evaluated the risk level of Korean population comparison to others, Hong Kong, U.S. and U.K. populations. LARs are lower with older ages for all populations of both sexes. We recommend CT screening after the age of 40 because from that age, LAR decreases and the danger of top 5 cancer increases.

  15. Does Antibiotic Treatment Affect the Diagnostic Accuracy of 18F-FDG PET/CT Studies in Patients with Suspected Infectious Processes?

    Science.gov (United States)

    Kagna, Olga; Kurash, Marina; Ghanem-Zoubi, Nesrin; Keidar, Zohar; Israel, Ora

    2017-11-01

    18 F-FDG PET/CT plays a significant role in the assessment of various infectious processes. Patients with suspected or known sites of infection are often referred for 18 F-FDG imaging while already receiving antibiotic treatment. The current study assessed whether antibiotic therapy affected the detectability rate of infectious processes by 18 F-FDG PET/CT. Methods: A 5-y retrospective study of all adult patients who underwent 18 F-FDG PET/CT in search of a focal source of infection was performed. The presence, duration, and appropriateness of antibiotic treatment before 18 F-FDG imaging were recorded. Diagnosis of an infectious process was based on microbiologic or pathologic data as well as on clinical and radiologic follow-up. Results: Two hundred seventeen patients underwent 243 PET/CT studies in search of a focal source of infection and were included in the study. Sixty-seven studies were excluded from further analysis because of a final noninfectious etiology or lack of further follow-up or details regarding the antibiotic treatment. The final study population included 176 18 F-FDG PET/CT studies in 153 patients (107 men, 46 women; age range, 18-86 y). One hundred nineteen studies (68%) were performed in patients receiving antibiotic therapy for a range of 1-73 d. A diagnosis of infection was made in 107 true-positive cases (61%), including 63 studies (59%) in patients receiving appropriate antibiotic therapy started before the performance of the 18 F-FDG PET/CT study. There were 52 true-negative (29%) and 17 false-positive (10%) 18 F-FDG PET/CT studies. No false-negative results were found. Conclusion: 18 F-FDG PET/CT correctly identified foci of increased uptake compatible with infection in most patients, including all patients receiving appropriate antimicrobial therapy, with no false-negative cases. On the basis of the current study results, the administration of antibiotics appears to have no clinically significant impact on the diagnostic accuracy of 18

  16. Using potential performance theory to test five hypotheses about meta-attribution.

    Science.gov (United States)

    Trafimow, David; Hunt, Gayle; Rice, Stephen; Geels, Kasha

    2011-01-01

    Based on I. Kant's (1991) distinction between perfect and imperfect duties and the attribution literature pertaining to that distinction, the authors proposed and tested 5 hypotheses about meta-attribution. More specifically, violations of perfect duties have been shown to arouse both more negative affect and stronger correspondent inferences than do violations of imperfect duties (e.g., D. Trafimow, I. K. Bromgard, K. A. Finlay, & T. Ketelaar, 2005). But when it comes to making meta-attributions-that is, guessing the attributions others would make-is the affect differential an advantage or a disadvantage? In addition to the null hypothesis of no effect, the authors proposed and tested additional hypotheses about how negative affect might increase or decrease the effectiveness of people's meta-attribution strategies and how even if there is no effect on strategy effectiveness, negative affect could increase or decrease the consistencies with which these strategies could be used.

  17. Cardiac chambers and their walls in cardiomyopathies as evaluated with CT

    International Nuclear Information System (INIS)

    Wojtowicz, J.; Pawlak, B.; Lehman, Z.; Karwowski, A.; Akademia Medyczna, Poznan

    1984-01-01

    Thirty-two patients with cardiomyopathy, 25 with hypertrophic and 7 with dilated form were examined by cardiac catheterisation, left ventriculography, selective coronary angiography and ungated cardiac computed tomography. Diffuse hypertrophy, localized hypertrophy and dilated cardiomyopathy were diagnosed and assessed quantitatively based on CT linear, surface and volumetric parameters of cardiac morphology. Absolute septal thickness and left ventricular mass measured in CT image are the most discriminative attributes. (orig.)

  18. Measuring diversity in medical reports based on categorized attributes and international classification systems

    Directory of Open Access Journals (Sweden)

    Přečková Petra

    2012-04-01

    Full Text Available Abstract Background Narrative medical reports do not use standardized terminology and often bring insufficient information for statistical processing and medical decision making. Objectives of the paper are to propose a method for measuring diversity in medical reports written in any language, to compare diversities in narrative and structured medical reports and to map attributes and terms to selected classification systems. Methods A new method based on a general concept of f-diversity is proposed for measuring diversity of medical reports in any language. The method is based on categorized attributes recorded in narrative or structured medical reports and on international classification systems. Values of categories are expressed by terms. Using SNOMED CT and ICD 10 we are mapping attributes and terms to predefined codes. We use f-diversities of Gini-Simpson and Number of Categories types to compare diversities of narrative and structured medical reports. The comparison is based on attributes selected from the Minimal Data Model for Cardiology (MDMC. Results We compared diversities of 110 Czech narrative medical reports and 1119 Czech structured medical reports. Selected categorized attributes of MDMC had mostly different numbers of categories and used different terms in narrative and structured reports. We found more than 60% of MDMC attributes in SNOMED CT. We showed that attributes in narrative medical reports had greater diversity than the same attributes in structured medical reports. Further, we replaced each value of category (term used for attributes in narrative medical reports by the closest term and the category used in MDMC for structured medical reports. We found that relative Gini-Simpson diversities in structured medical reports were significantly smaller than those in narrative medical reports except the "Allergy" attribute. Conclusions Terminology in narrative medical reports is not standardized. Therefore it is nearly

  19. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Seoul National University Medical Research Center, Institute of Radiation Medicine, Bundang (Korea, Republic of); Kim, Kil Joong [Seoul National University College of Medicine, Department of Radiation Applied Life Science, Seoul (Korea, Republic of); Kim, Bohyoung; Lee, Hyunna [Seoul National University, School of Computer Science and Engineering, Seoul (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Yanof, Jeffrey H. [Philips Healthcare, CT Clinical Science, Cleveland, OH (United States); Hwang, Seung-sik [Inha University School of Medicine, Department of Social and Preventive Medicine, Incheon (Korea, Republic of)

    2011-02-15

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI{sub vol}) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI{sub vol} and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI{sub vol} varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI{sub vol} and ATT (p = 0.61). ATT did not significantly affect CTDI{sub vol} (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI{sub vol} (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  20. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    International Nuclear Information System (INIS)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon; Kim, Kil Joong; Kim, Bohyoung; Lee, Hyunna; Park, Seong Ho; Yanof, Jeffrey H.; Hwang, Seung-sik

    2011-01-01

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI vol ) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI vol and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI vol varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI vol and ATT (p = 0.61). ATT did not significantly affect CTDI vol (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI vol (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  1. Computed tomography (CT) in neuromuscular disorders

    International Nuclear Information System (INIS)

    Novak, M.; Ambler, Z.

    1997-01-01

    For 24 patients with confirmed neuromuscular disorders, the clinical picture of the disease was complemented with CT examination. It is concluded, in accordance with the literature, that CT has a supplementary value as regards the extent and degree of disorder of the affected muscle groups. The basic pathological picture includes muscular atrophies, dystrophies, hypertrophies, and their combinations. The CT images are non-specific for the individual neuromuscular disorders and are of minor importance in the diagnostic process. 1 tab., 7 figs., 6 refs

  2. Xanthogranulomatous pyelonephritis in childhood: ultrasound and CT diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, C [City Hospital, Nottingham (United Kingdom); Somers, J [City Hospital, Nottingham (United Kingdom); Broderick, N [City Hospital, Nottingham (United Kingdom); Rance, C [City Hospital, Nottingham (United Kingdom); Shaw, D [Hospital for Sick Children, London (United Kingdom)

    1994-06-01

    Four cases of diffuse xanthogranulomatous pyelonephritis (XPN) in young children are presented. In three patients the clinical picture was one of weight loss, anaemia and neutrophilia with a large renal mass. The fourth presented with haematuria. Ultrasound (US) and CT findings were almost identical in all four patients. US showed the affected kidney was massively enlarged but retained a reniform shape. Dilated fluid spaces containing calculi were present. CT confirmed the US findings and revealed peripheral enhancement without contrast excretion, with dilated calyceal spaces producing the ''bear paw sign''. Extrarenal extension into abdominal wall and psoas muscle is typical and was well demonstrated by CT. The affected kidneys were non-functioning and nephrectomy was required. Typical US and CT features allow a confident diagnosis of XPN and appropriate early treatment. (orig.)

  3. Xanthogranulomatous pyelonephritis in childhood: ultrasound and CT diagnosis

    International Nuclear Information System (INIS)

    Cousins, C.; Somers, J.; Broderick, N.; Rance, C.; Shaw, D.

    1994-01-01

    Four cases of diffuse xanthogranulomatous pyelonephritis (XPN) in young children are presented. In three patients the clinical picture was one of weight loss, anaemia and neutrophilia with a large renal mass. The fourth presented with haematuria. Ultrasound (US) and CT findings were almost identical in all four patients. US showed the affected kidney was massively enlarged but retained a reniform shape. Dilated fluid spaces containing calculi were present. CT confirmed the US findings and revealed peripheral enhancement without contrast excretion, with dilated calyceal spaces producing the ''bear paw sign''. Extrarenal extension into abdominal wall and psoas muscle is typical and was well demonstrated by CT. The affected kidneys were non-functioning and nephrectomy was required. Typical US and CT features allow a confident diagnosis of XPN and appropriate early treatment. (orig.)

  4. Customers' attributional judgments towards complaint handling in airline service: a confirmatory study based on attribution theory.

    Science.gov (United States)

    Chiou, Wen-Bin

    2007-06-01

    Besides flight safety, complaint handling plays a crucial role in airline service. Based upon Kelley's attribution theory, in the present study customers' attributions were examined under different conditions of complaint handling by the airlines. There were 531 passengers (216 women; ages 21 to 63 years, M = 41.5, SD = 11.1) with experiences of customer complaints who were recruited while awaiting boarding. Participants received one hypothetical scenario of three attributional conditions about complaint handling and then reported their attributional judgments. The findings indicated that the passengers were most likely to attribute the company's complaint handling to unconditional compliance when the airline company reacted to customer complaints under low distinctiveness, high consistency, and when consensus among the airlines was low. On the other hand, most passengers attributed the company's complaint handling to conditional compliance under the conditions in which distinctiveness, consistency, and consensus were all high. The results provide further insights into how different policies of complaint management affect customers' attributions. Future directions and managerial implications are also discussed.

  5. 18F-FDG PET/CT in Neurolymphomatosis: Report of 3 Cases

    International Nuclear Information System (INIS)

    Canh, Nguyen Xuan; Tan, Ngo Van; Tung, Tran Thanh; Son, Nguyen Truong; Maurea, Simone

    2014-01-01

    Neurolymphomatosis is a rare manifestation of non-Hodgkin lymphoma characterized by infiltration of peripheral nerves, nerve roots, plexus and cranial nerves by malignant lymphocytes. This report presents positron emission tomography/computed tomography (PET/CT)imaging with 2-deoxy-2- 18 F-fluoro-D-glucose ( 18 F-FDG) in 3 cases of non-Hodgkin lymphoma with nerve infiltration, including one newly diagnosed lymphoma, one recurrent lymphoma in previous nerve lesions and one newly recurrent lymphoma. PET/CT could reveal the affected neural structures including cranial nerves, spinal nerve roots, brachial plexus, cervicothoracic ganglion, intercostal nerves, branches of the vagus nerve, lumbosacral plexus and sciatic nerves. There was relative concordance between PET/CT and MRI in detection of affected cranial nerves. PET/CT seemed to be better than MRI in detection of affected peripheral nerves. 18 F-FDG PET/CT was a whole-body imaging technique with the ability to reveal the affected cranial nerves, peripheral nerves, nerve roots and plexus in non-Hodgkin lymphoma. A thorough understanding of disease and use of advanced imaging modalities will increasingly detect neurolymphomatosis

  6. Predictive value of {sup 18}F-FDG PET/CT in restaging patients affected by ovarian carcinoma: a multicentre study

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hanover (Germany); Alongi, Pierpaolo [University of Milano-Bicocca, Nuclear Medicine Unit, Milan (Italy); IRCSS San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); Evangelista, Laura; Saladini, Giorgio [Veneto Institute of Oncology IOV - IRCCS, Radiotherapy and Nuclear Medicine Unit, Padua (Italy); Picchio, Maria [IRCSS San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); Rensi, Marco; Geatti, Onelio [Hospital of Udine, Nuclear Medicine Department, Udine (Italy); Castello, Angelo; Laghai, Iashar [University of Florence, Nuclear Medicine Department, Florence (Italy); Popescu, Cristina E. [Niguarda Ca' Granda Hospital, Nuclear Medicine Department, Milan (Italy); Dolci, Carlotta; Crivellaro, Cinzia [University of Milan-Bicocca, Nuclear Medicine Department, San Gerardo Hospital, Tecnomed Foundation, Milan (Italy); Seghezzi, Silvia [Hospital of Treviglio, Nuclear Medicine Department, Treviglio, Bergamo (Italy); Kirienko, Margarita [University of Milano-Bicocca, Nuclear Medicine Unit, Milan (Italy); De Biasi, Vincenzo [Nuclear Medicine Department, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy); Cocciolillo, Fabrizio [Catholic University of the Sacred Heart, Nuclear Medicine Department, Rome (Italy); Quartuccio, Natale [University of Messina, Nuclear Medicine Unit, Department of Biomedical Sciences and of Morphological and Functional Images, Messina (Italy); Collaboration: Young AIMN Working Group

    2016-03-15

    Ovarian cancer is the eighth most common malignancy among women and has a high mortality rate. Prognostic factors able to drive an effective therapy are essential. {sup 18}F-Fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) has been investigated in patients with epithelial ovarian cancer and showed promise in diagnosing, staging, detecting recurrent lesions and monitoring treatment response. Conversely, its prognostic role remains unclear. We aimed at assessing the prognostic value of {sup 18}F-FDG PET/CT performed in the restaging process in a multicentre study. We evaluated 168 patients affected by ovarian carcinoma, who underwent a restaging {sup 18}F-FDG PET/CT. The presence of local recurrences, lymph node involvement and distant metastasis was recorded as well as lesion dimensions, maximum and mean standardized uptake values (SUV{sub max} and SUV{sub mean}, respectively). Progression-free survival (PFS) and overall survival (OS) at 3 and 4 years were computed by using Kaplan-Meier curves. Increased odds ratio was assessed using Cox regression analysis testing all lesion parameters measured by PET/CT. PFS was significantly longer in patients with a negative than a positive restaging PET/CT study (3- and 4-year PFS 64 and 53 % vs 23 and 12 %, respectively; p < 0.001). Similarly, a negative study was associated with a significantly higher OS rate after 4 years of follow-up (67 vs 25 % in negative and positive groups, respectively; p < 0.001). Lymph node or distant involvement were also independently associated with an increased risk of disease progression [hazard ratio (HR) 1.6 and 2.2, respectively; p = 0.003]. Moreover, PET/CT showed an incremental prognostic value compared to the International Federation of Gynecology and Obstetrics (FIGO) staging system. In the analysis of patient subsets, individuals with the same FIGO stage I-II but with negative PET had a significantly better 4-year OS than patients with low

  7. Hepatosplenic Candidiasis Detected by 18F-FDG-PET/CT

    International Nuclear Information System (INIS)

    Albano, Domenico; Bosio, Giovanni; Bertoli, Mattia; Petrilli, Giulia; Bertagna, Francesco

    2016-01-01

    Hepatosplenic candidiasis is a fungal infection, which mostly affects patients with hematologic malignancies such as leukemia. The pathogenesis of this infection is not clear yet, and the liver is the most commonly affected organ. Diagnosis of hepatosplenic candidiasis can be only established via biopsy, since computed tomography (CT) scan, ultrasonography, and magnetic resonance imaging (MRI) yield non-specific results. The role of fluorine-18 fluorodeoxyglucose positron emission tomography /computed tomography ( 18 F-FDG PET/CT) in diagnosis of hepatosplenic candidiasis remains undetermined, considering a few evidences in the literature. In this case report, we present the case of a 47-year-old patient, affected by acute myeloid leukemia, which was treated with three cycles of chemotherapy, resulting in the development of neutropenia and fever following the last cycle. The 18 F-FDG PET/CT scan showed some foci of intense FDG uptake in the liver and spleen. The subsequent diagnostic investigations (i.e., abdominal CT scan and biopsy) were suggestive of hepatosplenic candidiasis. The patient was started on antifungal treatment with fluconazole. After one month, the clinical conditions were resolved, and the subsequent abdominal CT scan was negative

  8. Temperature affects long-term productivity and quality attributes of day-neutral strawberry for a space life-support system

    Science.gov (United States)

    Massa, Gioia D.; Chase, Elaine; Santini, Judith B.; Mitchell, Cary A.

    2015-04-01

    Strawberry (Fragaria x ananassa L.) is a promising candidate crop for space life-support systems with desirable sensory quality and health attributes. Day-neutral cultivars such as 'Seascape' are adaptable to a range of photoperiods, including short days that would save considerable energy for crop lighting without reductions in productivity or yield. Since photoperiod and temperature interact to affect strawberry growth and development, several diurnal temperature regimes were tested under a short photoperiod of 10 h per day for effects on yield and quality attributes of 'Seascape' strawberry during production cycles longer than 270 days. The coolest day/night temperature regime, 16°/8 °C, tended to produce smaller numbers of larger fruit than did the intermediate temperature range of 18°/10 °C or the warmest regime, 20°/12 °C, both of which produced similar larger numbers of smaller fruit. The intermediate temperature regime produced the highest total fresh mass of berries over an entire production cycle. Independent experiments examined either organoleptic or physicochemical quality attributes. Organoleptic evaluation indicated that fruit grown under the coolest temperature regime tended to score the highest for both hedonic preference and descriptive evaluation of sensory attributes related to sweetness, texture, aftertaste, and overall approval. The physicochemical quality attributes Brix, pH, and sugar/acid ratio were highest for fruits harvested from the coolest temperature regime and lower for those from the warmer temperature regimes. The cool-regime fruits also were lowest in titratable acidity. The yield parameters fruit number and size oscillated over the course of a production cycle, with a gradual decline in fruit size under all three temperature regimes. Brix and titratable acidity both decreased over time for all three temperature treatments, but sugar/acid ratio remained highest for the cool temperature regime over the entire production

  9. Contribution of computed tomography (CT) in affections of the lung parenchyma in HIV positive patients

    International Nuclear Information System (INIS)

    Neuwirth, J.; Stankova, M.; Spala, J.; Strof, J.

    1996-01-01

    CT findings in HIV positive patients with respiratory complaints were analyzed. The predominant morphological type of changes is a 'ground glass' increased density. Minimal changes of the lung parenchyma were recorded on high resolution computed tomography (HRCT) even in patients with a negative or doubtful finding on plain chest radiographs. Also the range of affections on HRCT scans was wider than on simple scans. The morphological changes on HRCT scans alone, however, are not an adequate basis for differentiation of various infectious agents in inflammatory changes of the lung parenchyma, and frequently mixed infections are involved. When at the same time clinical symptoms are considered, it frequently is possible to considerably reduce the number of possible pathogenic organisms and to start treatment. (author) 4 figs., 11 refs

  10. CT of blunt chest trauma in children

    International Nuclear Information System (INIS)

    Manson, D.; Babyn, P.S.; Palder, S.; Bergmann, K.

    1993-01-01

    While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. Children demonstrating findings incidental to the actual injury yet important to the subsequent therapy are also presented. We conclude that, in the event of clinically significant blunt chest trauma, the single supine chest examination in the trauma room is insufficient to adequately identify the extent of intrathoracic injury. With the exception of concern for aortic injury for which aortography is indicated, a dynamically enhanced CT scan of the thorax should be performed as clinically significant findings may result in altered therapy. (orig.)

  11. Segmentation of Lung Structures in CT

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau

    This thesis proposes and evaluates new algorithms for segmenting various lung structures in computed tomography (CT) images, namely the lungs, airway trees and vessel trees. The main objective of these algorithms is to facilitate a better platform for studying Chronic Obstructive Pulmonary Disease......, 200 randomly selected CT scans were manually evaluated by medical experts, and only negligible or minor errors were found in nine scans. The proposed algorithm has been used to study how changes in smoking behavior affect CT based emphysema quantification. The algorithms for segmenting the airway...

  12. Contrasting lexical similarity and formal definitions in SNOMED CT: consistency and implications.

    Science.gov (United States)

    Agrawal, Ankur; Elhanan, Gai

    2014-02-01

    To quantify the presence of and evaluate an approach for detection of inconsistencies in the formal definitions of SNOMED CT (SCT) concepts utilizing a lexical method. Utilizing SCT's Procedure hierarchy, we algorithmically formulated similarity sets: groups of concepts with similar lexical structure of their fully specified name. We formulated five random samples, each with 50 similarity sets, based on the same parameter: number of parents, attributes, groups, all the former as well as a randomly selected control sample. All samples' sets were reviewed for types of formal definition inconsistencies: hierarchical, attribute assignment, attribute target values, groups, and definitional. For the Procedure hierarchy, 2111 similarity sets were formulated, covering 18.1% of eligible concepts. The evaluation revealed that 38 (Control) to 70% (Different relationships) of similarity sets within the samples exhibited significant inconsistencies. The rate of inconsistencies for the sample with different relationships was highly significant compared to Control, as well as the number of attribute assignment and hierarchical inconsistencies within their respective samples. While, at this time of the HITECH initiative, the formal definitions of SCT are only a minor consideration, in the grand scheme of sophisticated, meaningful use of captured clinical data, they are essential. However, significant portion of the concepts in the most semantically complex hierarchy of SCT, the Procedure hierarchy, are modeled inconsistently in a manner that affects their computability. Lexical methods can efficiently identify such inconsistencies and possibly allow for their algorithmic resolution. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Micro-CT characterization of human trabecular bone in osteogenesis imperfecta

    Science.gov (United States)

    Jameson, John; Albert, Carolyne; Smith, Peter; Molthen, Robert; Harris, Gerald

    2011-03-01

    Osteogenesis imperfecta (OI) is a genetic syndrome affecting collagen synthesis and assembly. Its symptoms vary widely but commonly include bone fragility, reduced stature, and bone deformity. Because of the small size and paucity of human specimens, there is a lack of biomechanical data for OI bone. Most literature has focused on histomorphometric analyses, which rely on assumptions to extrapolate 3-D properties. In this study, a micro-computed tomography (μCT) system was used to directly measure structural and mineral properties in pediatric OI bone collected during routine surgical procedures. Surface renderings suggested a poorly organized, plate-like orientation. Patients with a history of bone-augmenting drugs exhibited increased bone volume fraction (BV/TV), trabecular number (Tb.N), and connectivity density (Eu.Conn.D). The latter two parameters appeared to be related to OI severity. Structural results were consistently higher than those reported in a previous histomorphometric study, but these differences can be attributed to factors such as specimen collection site, drug therapy, and assumptions associated with histomorphometry. Mineral testing revealed strong correlations with several structural parameters, highlighting the importance of a dual approach in trabecular bone testing. This study reports some of the first quantitative μCT data of human OI bone, and it suggests compelling possibilities for the future of OI bone assessment.

  14. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... wear during the procedure. Metal objects, including jewelry, eyeglasses, dentures and hairpins, may affect the CT images ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... wear during the procedure. Metal objects, including jewelry, eyeglasses, dentures and hairpins, may affect the CT images ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... wear during the procedure. Metal objects, including jewelry, eyeglasses, dentures and hairpins, may affect the CT images ... and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media ...

  18. Gorlin-Goltz syndrome: incidental finding on routine ct scan following car accident.

    Science.gov (United States)

    Kalogeropoulou, Christina; Zampakis, Petros; Kazantzi, Santra; Kraniotis, Pantelis; Mastronikolis, Nicholas S

    2009-11-25

    Gorlin-Goltz syndrome is a rare hereditary disease. Pathogenesis of the syndrome is attributed to abnormalities in the long arm of chromosome 9 (q22.3-q31) and loss or mutations of human patched gene (PTCH1 gene). Multiple basal cell carcinomas (BCCs), odontogenic keratocysts, skeletal abnormalities, hyperkeratosis of palms and soles, intracranial ectopic calcifications of the falx cerebri and facial dysmorphism are considered the main clinical features. Diagnosis is based upon established major and minor clinical and radiological criteria and ideally confirmed by DNA analysis. Because of the different systems affected, a multidisciplinary approach team of various experts is required for a successful management. We report the case of a 19 year-old female who was involved in a car accident and found to present imaging findings of Gorlin-Goltz syndrome during a routine whole body computed tomography (CT) scan in order to exclude traumatic injuries. Radiologic findings of the syndrome are easily identifiable on CT scans and may prompt to early verification of the disease, which is very important for regular follow-up and better survival rates from the co-existent diseases.

  19. TH-C-18A-09: Exam and Patient Parameters Affecting the DNA Damage Response Following CT Studies

    International Nuclear Information System (INIS)

    Elgart, S; Adibi, A; Bostani, M; Ruehm, S; Enzmann, D; McNitt-Gray, M; Iwamoto, K

    2014-01-01

    Purpose: To identify exam and patient parameters affecting the biological response to CT studies using in vivo and ex vivo blood samples. Methods: Blood samples were collected under IRB approval from 16 patients undergoing clinically-indicated CT exams. Blood was procured prior to, immediately after and 30minutes following irradiation. A sample of preexam blood was placed on the patient within the exam region for ex vivo analysis. Whole blood samples were fixed immediately following collection and stained for γH2AX to assess DNA damage response (DDR). Median fluorescence of treated samples was compared to non-irradiated control samples for each patient. Patients were characterized by observed biological kinetic response: (a) fast — phosphorylation increased by 2minutes and fell by 30minutes, (b) slow — phosphorylation continued to increase to 30minutes and (c) none — little change was observed or irradiated samples fell below controls. Total dose values were normalized to exam time for an averaged dose-rate in dose/sec for each exam. Relationships between patient biological responses and patient and exam parameters were investigated. Results: A clearer dose response at 30minutes is observed for young patients (<61yoa; R2>0.5) compared to old patients (>61yoa; R 2 <0.11). Fast responding patients were significantly younger than slow responding patients (p<0.05). Unlike in vivo samples, age did not significantly affect the patient response ex vivo. Additionally, fast responding patients received exams with significantly smaller dose-rate than slow responding patients (p<0.05). Conclusion: Age is a significant factor in the biological response suggesting that DDR may be more rapid in a younger population and slower as the population ages. Lack of an agerelated response ex vivo suggests a systemic response to radiation not present when irradiated outside the body. Dose-rate affects the biological response suggesting that patient response may be related to scan

  20. Land cover changes affect soil chemical attributes in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Murilo Rezende Machado

    2017-05-01

    Full Text Available Forest plantations may minimize the effects of deforestation in the Amazon. However, there are differences among species in terms of their influences on soil recovery. The effects of monospecific plantations of Acacia mangium, Dipteryx odorata, Jacaranda copaia, Parkia decussata,and Swietenia macrophylla, and areas of pasture and native forest on the chemical soil attributes of the Brazilian Amazon were evaluated. One bulked soil sample was collected per plot (0.00-0.05, 0.05-0.10, and 0.10-0.30 m; three plots of 128 m2 in each area. No significant differences in most of the soil attributes were observed among the forest plantations. However, soil K+ and P were higher in the Swietenia macrophylla plantations, while higher values of Ca2+, sum of bases, and pH occurred in Jacaranda copaia plantations. In the native forest, the pH, and P content were lower, whereas the soil organic matter (SOM content, soil organic carbon (SOC content, cation exchange capacity (CEC, N content, H+Al content, and Al3+ content were higher than in the plantations. The lowest values of SOM, SOC, CEC, K+, Mg2+, N, H+Al, and Al3+ occurred in the pasture. None of the forest species led to the return of the original soil chemical attributes of the native forest. However, S. macrophylla and J. copaia plantations presented the highest positive edaphic influences.

  1. Periportal halo on CT: spectrum of causes

    International Nuclear Information System (INIS)

    Volpacchio, Mariano; Baltazar, Alberto D.; Santamarina, Mario G.; Casetta, Liliana; Cione, Rodrigo; Sanchez, Gimena; Vallejos, Nancy

    2003-01-01

    Purpose: A periportal hypodense halo is a relatively frequent CT finding. This halo is attributed to the presence of edema or ecstatic lymphatic channels. In our series we illustrate the CT appearance of periportal edema and analyze its causes. Material and Methods: In a retrospective study we analyze a 78 patients series who showed periportal edema on e.v. contrast-enhanced abdominal CTs. The different causes of hepatic periportal edema (demonstrated on CT exams), were established by clinical, laboratory, surgical and anatomo-pathologic correlation. Results: In this study, 49 cases were diagnosed as having congestive heart failure (62,8%), 14 patients had viral hepatitis (18%), 5 patients had recently undergone orthotopic liver transplantation (6.4%), 3 patients had a diagnosis of infectious cholangitis (3.8%), 3 patients had abdominal trauma (3.8%), 2 patients had neoplastic disease (2.6%) and 2 patients had toxic hepatitis (2.6%). Conclusion: Periportal edema is a frequent and nonspecific finding associated with systemic diseases as well as liver specific entities. The integration of CT findings and clinical picture of periportal edema leads to a confident diagnosis of the main cause in most patients. (author)

  2. Malrotation with midgut volvulus: CT findings of bowel infarction

    International Nuclear Information System (INIS)

    Aidlen, Jeremy; Anupindi, Sudha A.; Jaramillo, Diego; Doody, Daniel P.

    2005-01-01

    Midgut volvulus, the most common serious complication of malrotation, can be diagnosed using conventional contrast fluoroscopy, US or CT. CT is a quick and comprehensive examination in the evaluation of complex acute abdominal pathology in children. Contrast-enhanced CT can readily help the radiologist recognize perfusion abnormalities of the bowel, which is vital for reducing morbidity and mortality in affected children. Our case emphasizes and demonstrates additional CT features of bowel infarction in a child with a proven malrotation with midgut volvulus. (orig.)

  3. Malrotation with midgut volvulus: CT findings of bowel infarction

    Energy Technology Data Exchange (ETDEWEB)

    Aidlen, Jeremy [University of Massachusetts Medical Center, Department of Surgery, Worchester (United States); Anupindi, Sudha A.; Jaramillo, Diego [Massachusetts General Hospital, Pediatric Radiology, Boston, MA (United States); Doody, Daniel P. [Massachusetts General Hospital, Department of Pediatric Surgery, Boston, MA (United States)

    2005-05-01

    Midgut volvulus, the most common serious complication of malrotation, can be diagnosed using conventional contrast fluoroscopy, US or CT. CT is a quick and comprehensive examination in the evaluation of complex acute abdominal pathology in children. Contrast-enhanced CT can readily help the radiologist recognize perfusion abnormalities of the bowel, which is vital for reducing morbidity and mortality in affected children. Our case emphasizes and demonstrates additional CT features of bowel infarction in a child with a proven malrotation with midgut volvulus. (orig.)

  4. CT study in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji [Tokyo Metropolitan Matsuzawa Hospital (Japan)

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, II and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefore, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease.

  5. CT study in Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, Ii and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefor, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease. (J.P.N.)

  6. C-tactile afferent stimulating touch carries a positive affective value.

    Science.gov (United States)

    Pawling, Ralph; Cannon, Peter R; McGlone, Francis P; Walker, Susannah C

    2017-01-01

    The rewarding sensation of touch in affiliative interactions is hypothesized to be underpinned by a specialized system of nerve fibers called C-Tactile afferents (CTs), which respond optimally to slowly moving, gentle touch, typical of a caress. However, empirical evidence to support the theory that CTs encode socially relevant, rewarding tactile information in humans is currently limited. While in healthy participants, touch applied at CT optimal velocities (1-10cm/sec) is reliably rated as subjectively pleasant, neuronopathy patients lacking large myelinated afferents, but with intact C-fibres, report that the conscious sensation elicited by stimulation of CTs is rather vague. Given this weak perceptual impact the value of self-report measures for assessing the specific affective value of CT activating touch appears limited. Therefore, we combined subjective ratings of touch pleasantness with implicit measures of affective state (facial electromyography) and autonomic arousal (heart rate) to determine whether CT activation carries a positive affective value. We recorded the activity of two key emotion-relevant facial muscle sites (zygomaticus major-smile muscle, positive affect & corrugator supercilii-frown muscle, negative affect) while participants evaluated the pleasantness of experimenter administered stroking touch, delivered using a soft brush, at two velocities (CT optimal 3cm/sec & CT non-optimal 30cm/sec), on two skin sites (CT innervated forearm & non-CT innervated palm). On both sites, 3cm/sec stroking touch was rated as more pleasant and produced greater heart rate deceleration than 30cm/sec stimulation. However, neither self-report ratings nor heart rate responses discriminated stimulation on the CT innervated arm from stroking of the non-CT innervated palm. In contrast, significantly greater activation of the zygomaticus major (smiling muscle) was seen specifically to CT optimal, 3cm/sec, stroking on the forearm in comparison to all other stimuli

  7. C-tactile afferent stimulating touch carries a positive affective value.

    Directory of Open Access Journals (Sweden)

    Ralph Pawling

    Full Text Available The rewarding sensation of touch in affiliative interactions is hypothesized to be underpinned by a specialized system of nerve fibers called C-Tactile afferents (CTs, which respond optimally to slowly moving, gentle touch, typical of a caress. However, empirical evidence to support the theory that CTs encode socially relevant, rewarding tactile information in humans is currently limited. While in healthy participants, touch applied at CT optimal velocities (1-10cm/sec is reliably rated as subjectively pleasant, neuronopathy patients lacking large myelinated afferents, but with intact C-fibres, report that the conscious sensation elicited by stimulation of CTs is rather vague. Given this weak perceptual impact the value of self-report measures for assessing the specific affective value of CT activating touch appears limited. Therefore, we combined subjective ratings of touch pleasantness with implicit measures of affective state (facial electromyography and autonomic arousal (heart rate to determine whether CT activation carries a positive affective value. We recorded the activity of two key emotion-relevant facial muscle sites (zygomaticus major-smile muscle, positive affect & corrugator supercilii-frown muscle, negative affect while participants evaluated the pleasantness of experimenter administered stroking touch, delivered using a soft brush, at two velocities (CT optimal 3cm/sec & CT non-optimal 30cm/sec, on two skin sites (CT innervated forearm & non-CT innervated palm. On both sites, 3cm/sec stroking touch was rated as more pleasant and produced greater heart rate deceleration than 30cm/sec stimulation. However, neither self-report ratings nor heart rate responses discriminated stimulation on the CT innervated arm from stroking of the non-CT innervated palm. In contrast, significantly greater activation of the zygomaticus major (smiling muscle was seen specifically to CT optimal, 3cm/sec, stroking on the forearm in comparison to all

  8. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  9. Interplay between marital attributions and conflict behavior in predicting depressive symptoms.

    Science.gov (United States)

    Ellison, Jenna K; Kouros, Chrystyna D; Papp, Lauren M; Cummings, E Mark

    2016-03-01

    Marital attributions-that is, causal inferences and explanations spouses make about their partners' behavior-have been implicated as predictors of relationship functioning. Extending previous work, we examined marital attributions as a moderator of the link between marital conflict and depressive symptoms 1 year later. Participants were 284 couples who reported on marital attributions and depressive symptoms. Couples also engaged in a videotaped marital conflict interaction, which was later coded for specific conflict behaviors. The results showed that husbands' and wives' marital attributions about their partner moderated relations between marital conflict behavior and later depressive symptoms, controlling for global marital sentiments. For husbands, positive behavior and affect during marital conflict predicted a decrease in depressive symptoms, but only for husbands' who made low levels of responsibility and causal attributions about their wives. Wives' causal attributions about their partner also moderated relations between positive behavior and affect during marital conflict and husbands' later depressive symptoms. Reflecting an unexpected finding, negative behavior and affect during marital conflict predicted increases in wives' depressive symptoms, but only for wives who made low levels of responsibility attributions about their partner. The findings suggest that, for husbands, low levels of negative marital attributions for spouses may be protective, strengthening the positive effect of constructive conflict behaviors for their mental health, whereas for wives low levels of responsibility attributions about their spouse may be a risk factor, exacerbating the negative effect of negative marital conflict behaviors on their later depressive symptoms. (c) 2016 APA, all rights reserved).

  10. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.; Mohamed Hoesein, Firdaus A A; de Jong, Pim A.

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and

  11. Prognostic value of {sup 18}F-DOPA PET/CT at the time of recurrence in patients affected by neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Piccardo, Arnoldo [Galliera Hospital, Nuclear Medicine Unit, Genoa (Italy); E.O. Ospedali Galliera, Department of Nuclear Medicine, Genoa (Italy); Puntoni, Matteo [Galliera Hospital, Clinical Trial Research Unit, Genoa (Italy); Lopci, Egesta; Fanti, Stefano [Sant' Orsola-Malpighi Hospital, Nuclear Medicine Unit, Bologna (Italy); Conte, Massimo; Sorrentino, Stefania; Garaventa, Alberto [G. Gaslini Children' s Hospital, Department of Hematology-Oncology, Genoa (Italy); Foppiani, Luca [Galliera Hospital, Internal Medicine, Genoa (Italy); Morana, Giovanni [G. Gaslini Children' s Hospital, Department of Pathology and Radiology, Genoa (Italy); Naseri, Mehrdad; Villavecchia, Giampiero [Galliera Hospital, Nuclear Medicine Unit, Genoa (Italy); Cistaro, Angelina [IRMET, PET Centre, Turin (Italy)

    2014-06-15

    The aim of this study was to investigate the relationship between {sup 123}I-metaiodobenzylguanidine (MIBG) scan semi-quantification and a new {sup 18}F-DOPA positron emission tomography (PET)/CT score in patients with suspected or documented neuroblastoma (NB) relapse and to assess the association between these two parameters and progression-free survival (PFS)/overall survival (OS). We analysed 24 NB patients who had undergone {sup 123}I-MIBG and {sup 18}F-DOPA PET/CT scans at the time of suspected relapse, after applying a proper scoring system for each scan. In time-to-event analyses, the score distributions were regarded as continuous and were categorized in tertiles and medians. We used Kaplan-Meier curves and Cox proportional hazard models for PFS and OS in order to estimate the independent prognostic impact of {sup 123}I-MIBG and {sup 18}F-DOPA PET/CT scans. The {sup 123}I-MIBG and {sup 18}F-DOPA scores were highly and positively correlated (Spearman's rho = 0.8, p < 0.001). Over a median follow-up of 14 months (range 6-82), 12 cases of disease progression and 6 deaths occurred. Multivariate Cox models showed a higher risk of disease progression [hazard ratio (HR) 17.0, 95 % confidence interval (CI) 2.7-109] in NB patients with {sup 123}I-MIBG score > 3 (3rd tertile) and an even higher risk (HR:37.2, 95 % CI 2.4-574) in those with {sup 18}F-DOPA whole-body metabolic burden (WBMB) >7.5 (median), after adjustment for all main clinical/pathological factors considered. Kaplan-Meier analyses showed a significant association with OS (log-rank p = 0.01 and p = 0.03 for {sup 123}I-MIBG and {sup 18}F-DOPA WBMB, respectively). Our results confirm the good agreement between {sup 18}F-DOPA PET/CT and {sup 123}I-MIBG scan in patients affected by NB relapse. In time-to-event analyses, {sup 123}I-MIBG scan and {sup 18}F-DOPA PET/CT scores were independently and significantly associated with disease progression. (orig.)

  12. Predicting adenocarcinoma recurrence using computational texture models of nodule components in lung CT

    International Nuclear Information System (INIS)

    Depeursinge, Adrien; Yanagawa, Masahiro; Leung, Ann N.; Rubin, Daniel L.

    2015-01-01

    Purpose: To investigate the importance of presurgical computed tomography (CT) intensity and texture information from ground-glass opacities (GGO) and solid nodule components for the prediction of adenocarcinoma recurrence. Methods: For this study, 101 patients with surgically resected stage I adenocarcinoma were selected. During the follow-up period, 17 patients had disease recurrence with six associated cancer-related deaths. GGO and solid tumor components were delineated on presurgical CT scans by a radiologist. Computational texture models of GGO and solid regions were built using linear combinations of steerable Riesz wavelets learned with linear support vector machines (SVMs). Unlike other traditional texture attributes, the proposed texture models are designed to encode local image scales and directions that are specific to GGO and solid tissue. The responses of the locally steered models were used as texture attributes and compared to the responses of unaligned Riesz wavelets. The texture attributes were combined with CT intensities to predict tumor recurrence and patient hazard according to disease-free survival (DFS) time. Two families of predictive models were compared: LASSO and SVMs, and their survival counterparts: Cox-LASSO and survival SVMs. Results: The best-performing predictive model of patient hazard was associated with a concordance index (C-index) of 0.81 ± 0.02 and was based on the combination of the steered models and CT intensities with survival SVMs. The same feature group and the LASSO model yielded the highest area under the receiver operating characteristic curve (AUC) of 0.8 ± 0.01 for predicting tumor recurrence, although no statistically significant difference was found when compared to using intensity features solely. For all models, the performance was found to be significantly higher when image attributes were based on the solid components solely versus using the entire tumors (p < 3.08 × 10 −5 ). Conclusions: This study

  13. CT numbers of liver and spleen in normal children

    International Nuclear Information System (INIS)

    Kim, Young Kim

    2002-01-01

    To determine the mean liver CT numbers, and differences between liver and spleen, and liver and back muscle CT numbers in normal children, and to correlate the findings with sex and age. One hundred and five normal children aged 2-14 years underwent pre-contrast CT scanning. Mean CT numbers of the liver, spleen, and back muscles were calculated, as well as the differences in CT numbers between the liver and spleen (liver-spleen CT numbers), and between the liver-back muscle CT numbers were 70.22±6.51 HU, 53.28±3.57 HU, 17.13±6.57 HU, and 11.88±5.94 HU, respectively. Mean liver CT numbers and the difference between liver and back muscle CT numbers were not different by age. By sex, all the CT numbers did not vary according to age. The sex of a subject did not affect the CT number. The children's mean liver CT number was 70.22±6.51 HU and the difference between liver and spleen CT numbers was 17.13±6.57 HU. Younger children had higher liver CT and liver-spleen CT numbers than older children. No CT numbers varied according to sex

  14. Cochlear pathology: CT and MRI findings

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a retrospective analysis of 50 patients with perceptive hearing loss. The neuro physiological work-up (evoked potentials, audiometric tests and otoemissions) identified the cochlea as the site of origin of the hearing loss. The imaging studies (high resolution CT and MR, including 3D volumes) showed petrous bone trauma (n=5) infections (bacterial or viral origin) (n=12) otosclerosis (n=8), Paget disease (n=3), and labyrinthine neurinomas (n=2). The other 20 cases showed development-linked disorders (Mitchel's, Mondini, Scheibe, Alexander, and hypoplasia of the cochlear canal). Imaging with CT and MR can identify in detail the structural abnormality affecting the cochlea and occasionally the immediate peri-cochlear region (otic capsule); the affected portion of the cochlea may thus be determined. (author)

  15. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  16. State-level Medicaid expenditures attributable to smoking.

    Science.gov (United States)

    Armour, Brian S; Finkelstein, Eric A; Fiebelkorn, Ian C

    2009-07-01

    Medicaid recipients are disproportionately affected by tobacco-related disease because their smoking prevalence is approximately 53% greater than that of the overall US adult population. This study estimates state-level smoking-attributable Medicaid expenditures. We used state-level and national data and a 4-part econometric model to estimate the fraction of each state's Medicaid expenditures attributable to smoking. These fractions were multiplied by state-level Medicaid expenditure estimates obtained from the Centers for Medicare and Medicaid Services to estimate smoking-attributable expenditures. The smoking-attributable fraction for all states was 11.0% (95% confidence interval, 0.4%-17.0%). Medicaid smoking-attributable expenditures ranged from $40 million (Wyoming) to $3.3 billion (New York) in 2004 and totaled $22 billion nationwide. Cigarette smoking accounts for a sizeable share of annual state Medicaid expenditures. To reduce smoking prevalence among recipients and the growth rate in smoking-attributable Medicaid expenditures, state health departments and state health plans such as Medicaid are encouraged to provide free or low-cost access to smoking cessation counseling and medication.

  17. Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

    International Nuclear Information System (INIS)

    Khawaja, Ranish Deedar Ali; Singh, Sarabjeet; Otrakji, Alexi; Padole, Atul; Lim, Ruth; Nimkin, Katherine; Westra, Sjirk; Kalra, Mannudeep K.; Gee, Michael S.

    2015-01-01

    Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT. (orig.)

  18. Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, Ranish Deedar Ali; Singh, Sarabjeet; Otrakji, Alexi; Padole, Atul; Lim, Ruth; Nimkin, Katherine; Westra, Sjirk; Kalra, Mannudeep K.; Gee, Michael S. [MGH Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2015-07-15

    Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT. (orig.)

  19. THE INTERDEPENDANCE BETWEEN ATTRIBUTIONS AND SECOND LANGUAGE ATTAINMENTS IN SECONDARY SCHOOL STUDENTS

    Directory of Open Access Journals (Sweden)

    Bogusława Gosiewska-Turek

    2017-07-01

    Full Text Available Affective factors are undoubtedly considered to be vital in second language acquisition. Among these factors attribution theory is of primary significance, as it affects learners’ final achievement. It indicates that people attribute various causes in their lives to their success and failure. With the employment of attribution theory, this study examines Polish secondary school adolescent students’ attributions for success and failure in second language learning. The main purpose of the study is to investigate, whether Polish secondary school students’ attributions have an impact on their achievements in second language acquisition. In order to conduct the study, the researcher administered attribution questionnaires to the students and an achievement sheet to the teacher to fill in with students’ semester grades in English. Then the data obtained from the questionnaires and the achievement sheet were correlated. The results show that successful students are more likely to attribute their success to internal facets such as ability and effort and unsuccessful learners attribute their lack of success to external factors, among which task difficulty or luck could be enumerated.

  20. CT and MRI of vertebral haemangiomas

    International Nuclear Information System (INIS)

    Braitinger, S.; Weigert, F.; Held, P.; Obletter, N.; Breit, A.

    1989-01-01

    A retrospective comparative study of CT and MRI was carried out involving 38 vertebral haemangiomas; this revealed a typical signal pattern on MRI from benign lesions. It consists of a hyper-intense signal from the bone marrow affecting the T 1 /T 2 sequences; this may be focal or involve the entire vertebral body. These characteristic signals were compared with CT images of the spine. The areas of bone that produce the high intensity signals on MRI appear on CT as spongey patterns with hypertrophic trabeculae surrounding mostly areas with negative absorption values. An analysis of the changes in the spongiosa has revealed three clearly defined types. The signals derived from haemangiomas extending beyond the bone have an intensity of normal spongiosa; this corresponds with an absence of fat, as demonstrated by CT. Extra-osseous components have low intensity T 1 signals that increase in T 2 sequences. (orig.) [de

  1. Elementary representative sizes of soil attributes via attenuation of gamma rays and computerized tomography

    International Nuclear Information System (INIS)

    Borges, Jaqueline Aparecida Ribaski

    2015-01-01

    In this study, the Computed Tomography (CT) and gamma-ray attenuation (GRA) techniques were used in the investigation of representative sample sizes for attributes related to soil structure. First of all, the representative elementary length (REL) for experimental measurements of soil mass attenuation coefficient (μes), of samples from a sandy and a clayey soil, was analyzed. The study was conducted with two radioactive sources ( 241 Am and 137 Cs), three collimators (2 - 4 mm diameters), and 14 thickness (x) samples (2-5 cm). From these analyzes, it was possible to identify an ideal thickness range for each of the studied sources (2-4 cm and 12-15 cm for the sources of 241 Am and 137 Cs, respectively). The application of such results in representative elementary area evaluations, in clayey soil clods via CT, indicated that experimental soil mass attenuation coefficient average values obtained for x>4 cm and source 241 Am might induce the use of samples which are not large enough for soil bulk density evaluations. Subsequently, μCT images with a total volume of 39×39×33 mm 3 and spatial resolution of 60 μm were used for macroporous system morphological characterization of a Rhodic Ferralsol with clayey texture, under no-till (NT) and conventional till (CT) systems. Attributes as macroporosity (MAP), number of macropores (NMAP), tortuosity (τ) and connectivity (C) of the pores were assessed. The C degree was estimated based on the Euler-Poincare characteristic (EPC). Once 3D images enable the study of these attributes in different sample volumes, the proposed study is ideal for the analysis of representative elementary volume (REV). Usually, the selection of subvolumes for REV analysis occurs concentrically to a small volume or in adjacent positions. Here, we introduced a new method for selecting the positions of subvolumes, which are randomly chosen within the total image volume (random selection). It was observed that higher fluctuations in amplitude of each

  2. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  3. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  4. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  5. Estimating radiation risk induced by CT screening for Korean population

    Science.gov (United States)

    Yang, Won Seok; Yang, Hye Jeong; Min, Byung In

    2017-02-01

    The purposes of this study are to estimate the radiation risks induced by chest/abdomen computed tomography (CT) screening for healthcare and to determine the cancer risk level of the Korean population compared to other populations. We used an ImPACT CT Patient Dosimetry Calculator to compute the organ effective dose induced by CT screening (chest, low-dose chest, abdomen/pelvis, and chest/abdomen/pelvis CT). A risk model was applied using principles based on the BEIR VII Report in order to estimate the lifetime attributable risk (LAR) using the Korean Life Table 2010. In addition, several countries including Hong Kong, the United States (U.S.), and the United Kingdom, were selected for comparison. Herein, each population exposed radiation dose of 100 mSv was classified according to country, gender and age. For each CT screening the total organ effective dose calculated by ImPACT was 6.2, 1.5, 5.2 and 11.4 mSv, respectively. In the case of Korean female LAR, it was similar to Hong Kong female but lower than those of U.S. and U.K. females, except for those in their twenties. The LAR of Korean males was the highest for all types of CT screening. However, the difference of the risk level was negligible because of the quite low value.

  6. Importance of Preoperative Rectal Ultrasound and CT in Rectal Tumors

    International Nuclear Information System (INIS)

    Schnellyova, T.

    2011-01-01

    Introduction: The reason of high mortality of colorectal carcinoma is above all the fact, that majority of diseases are detected in progressive stage. Radical change in this unfavorable mortality rate can be achieved only by targeted search for early stages of the disease. Early diagnostics consists in rectoscopy and colonoscopy. Regarding X-ray methods it is X-ray irigography. Regarding CT examinations it is CT irigography, virtual colonoscopy. Another examination can be USG examination of abdomen and endo sonographic examination of rectum. Materials and methods: In the period from June 2006 to December 2010, in 60 patients out of the total number 106 examined patients, tumorous affection of rectum CT examination of pelvis and abdomen separately or pelvisand abdomen at one session was made in 3186 patients. In 115 patients we discovered malign tumorous illness of colon. Metastatic affection in the form of distant metastases was proven n 63 patients. 403 patients had CT irigography examination. In 77 out of them we diagnosed colon carcinoma. CT colonoscopy did not discover in our group of 30 patients examined the presence of colon carcinoma. Results: In the group of 60 patients who were diagnosed rectal carcinoma, in 29 patients expansive infiltrative affection was evaluated in endorectal sonography, histologically confirmed in 28 patients - 96,5 %, expansive affection in 41 patients with histological verification in 100 %. With CT we diagnosed 52 expansive tumorous processes, histologically confirmed in 47 patients - 90,38 %. In 63 patients expansive infiltrative process was evaluated, histologically confirmed in 52 patients 82,53 %. In total of 115 examinations there was conformance with histological examination in 99 patients - 86,08 %. In CT irigography we diagnosed colon tumour in 77 patients. Expansive growth was evaluated in 40 patients, histologically confirmed in 37 patients - 92,5 %. Expansive infiltrative expansion was evaluated in 37 patients, with

  7. Quality attributes of pistachio nuts as affected by rootstock and deficit irrigation.

    Science.gov (United States)

    Carbonell-Barrachina, Ángel A; Memmi, Houssem; Noguera-Artiaga, Luis; Gijón-López, María del Carmen; Ciapa, Rafał; Pérez-López, David

    2015-11-01

    In this work, the influence of two regulated deficit irrigation (RDI) treatments and three different rootstocks on the quality of pistachios was evaluated by analyzing different parameters: morphological analysis, physicochemical analysis and sensory analysis. The results obtained in terms of the choice of rootstock revealed that Pistacia atlantica had increased production yields, nut weight, mineral content, higher intensities of characteristic sensory attributes and a higher degree of consumer satisfaction, than the other rootstocks studied. Moreover, the results established that the application of RDI on pistachio cultivation had no significant influence on production yield, weight, size, colour, water activity or mineral composition. Furthermore, T1 treatment (stem water potential < -1.3 MPa) resulted in higher intensities of characteristic sensory attributes and a greater level of satisfaction among international consumers. These results confirm that the application of deficit irrigation (T1) contributes to an increase in overall product quality. Furthermore, Pistacia atlantica rootstock provided better yield and quality than the other rootstocks studied. © 2014 Society of Chemical Industry.

  8. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  9. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  10. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  11. Social cognition and the manic defense: attributions, selective attention, and self-schema in bipolar affective disorder.

    Science.gov (United States)

    Lyon, H M; Startup, M; Bentall, R P

    1999-05-01

    Manic patients, depressed bipolar patients, and normal controls were compared on measures of social cognition. Manic patients showed a normal self-serving bias on the Attributional Style Questionnaire, but depressed patients attributed negative events more than positive events to self. On an implicit test of attributional style, both patient groups attributed negative events more than positive events to self. Both patient groups showed slowed color naming for depression-related but not euphoria-related words. Manic patients, like normal controls, endorsed mainly positive words as true of self but, like the depressed patients, recalled mainly negative words. Findings from the implicit tests indicate a common form of psychological organization in manic and depressed patients, whereas the contrasts between the scores on the implicit and explicit measures are consistent with the hypothesis of a manic defense.

  12. Bowel preparation for CT colonography

    International Nuclear Information System (INIS)

    Neri, Emanuele; Lefere, Philippe; Gryspeerdt, Stefaan; Bemi, Pietro; Mantarro, Annalisa; Bartolozzi, Carlo

    2013-01-01

    Bowel preparation represents an essential part of CT colonography, as the accuracy of the exam is strongly related to the adequacy of colonic cleansing, and a poor bowel preparation may compromise the diagnostic quality even despite optimization of all other acquisition parameters. Residual stool and fluid in the large bowel may affect the interpretation of the exam and may increase the number of false positives and false negatives. In this regard, the majority of patients having undergone CT colonography state that bowel preparation is the most unpleasant part. Unfortunately, to date no definite consensus has been reached about the ideal bowel preparation technique, and there is great variability in preparation strategies across diagnostic centers. The purpose of this review article is to describe the development and evolution of bowel preparation techniques in order to choose the best approach for optimizing the diagnostic quality of CT colonography in each patient

  13. Bowel preparation for CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Emanuele, E-mail: emanuele.neri@med.unipi.it [Diagnostic and Interventional Radiology, University of Pisa (Italy); Lefere, Philippe; Gryspeerdt, Stefaan [Department of Radiology, Stedelijk Ziekenhuis, Roeselare (Belgium); Bemi, Pietro; Mantarro, Annalisa; Bartolozzi, Carlo [Diagnostic and Interventional Radiology, University of Pisa (Italy)

    2013-08-15

    Bowel preparation represents an essential part of CT colonography, as the accuracy of the exam is strongly related to the adequacy of colonic cleansing, and a poor bowel preparation may compromise the diagnostic quality even despite optimization of all other acquisition parameters. Residual stool and fluid in the large bowel may affect the interpretation of the exam and may increase the number of false positives and false negatives. In this regard, the majority of patients having undergone CT colonography state that bowel preparation is the most unpleasant part. Unfortunately, to date no definite consensus has been reached about the ideal bowel preparation technique, and there is great variability in preparation strategies across diagnostic centers. The purpose of this review article is to describe the development and evolution of bowel preparation techniques in order to choose the best approach for optimizing the diagnostic quality of CT colonography in each patient.

  14. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  15. Chest CT in children: anesthesia and atelectasis

    International Nuclear Information System (INIS)

    Newman, Beverley; Gawande, Rakhee; Krane, Elliot J.; Holmes, Tyson H.; Robinson, Terry E.

    2014-01-01

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  16. Explaining Real-Life Events: How Culture and Domain Shape Attributions.

    Science.gov (United States)

    Lee, Fiona; And Others

    1996-01-01

    Research has shown that attributional styles are affected by the attributor's culture, inferential goals, and level of cognitive processing. This study compares the attributions made in sports articles and editorials of newspapers published in Hong Kong and the United States. Implications for the mixed model of social inference are discussed. (LSR)

  17. Correlative CT and anatomic study of the sciatic nerve

    International Nuclear Information System (INIS)

    Pech, P.; Haughton, V.

    1985-01-01

    Sciatica can be caused by numerous processes affecting the sciatic nerve or its components within the pelvis including tumors, infectious diseases, aneurysms, fractures, and endometriosis. The CT diagnosis of these causes of sciatica has not been emphasized. This study identified the course and appearance of the normal sciatic nerve in the pelvis by correlating CT and anatomic slices in cadavers. For purposes of discussion, the sciatic nerve complex is conveniently divided into three parts: presacral, muscular, and ischial. Each part is illustrated here by two cryosections with corresponding CT images

  18. Culture, attribution and automaticity: a social cognitive neuroscience view.

    Science.gov (United States)

    Mason, Malia F; Morris, Michael W

    2010-06-01

    A fundamental challenge facing social perceivers is identifying the cause underlying other people's behavior. Evidence indicates that East Asian perceivers are more likely than Western perceivers to reference the social context when attributing a cause to a target person's actions. One outstanding question is whether this reflects a culture's influence on automatic or on controlled components of causal attribution. After reviewing behavioral evidence that culture can shape automatic mental processes as well as controlled reasoning, we discuss the evidence in favor of cultural differences in automatic and controlled components of causal attribution more specifically. We contend that insights emerging from social cognitive neuroscience research can inform this debate. After introducing an attribution framework popular among social neuroscientists, we consider findings relevant to the automaticity of attribution, before speculating how one could use a social neuroscience approach to clarify whether culture affects automatic, controlled or both types of attribution processes.

  19. Comparison of Xenon-Enhanced Area-Detector CT and Krypton Ventilation SPECT/CT for Assessment of Pulmonary Functional Loss and Disease Severity in Smokers.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Takenaka, Daisuke; Kaminaga, Shigeo; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2018-02-01

    The objective of this study was to compare the capability of xenon-enhanced area-detector CT (ADCT) performed with a subtraction technique and coregistered 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity in smokers. Forty-six consecutive smokers (32 men and 14 women; mean age, 67.0 years) underwent prospective unenhanced and xenon-enhanced ADCT, 81m Kr-ventilation SPECT/CT, and pulmonary function tests. Disease severity was evaluated according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification. CT-based functional lung volume (FLV), the percentage of wall area to total airway area (WA%), and ventilated FLV on xenon-enhanced ADCT and SPECT/CT were calculated for each smoker. All indexes were correlated with percentage of forced expiratory volume in 1 second (%FEV 1 ) using step-wise regression analyses, and univariate and multivariate logistic regression analyses were performed. In addition, the diagnostic accuracy of the proposed model was compared with that of each radiologic index by means of McNemar analysis. Multivariate logistic regression showed that %FEV 1 was significantly affected (r = 0.77, r 2 = 0.59) by two factors: the first factor, ventilated FLV on xenon-enhanced ADCT (p < 0.0001); and the second factor, WA% (p = 0.004). Univariate logistic regression analyses indicated that all indexes significantly affected GOLD classification (p < 0.05). Multivariate logistic regression analyses revealed that ventilated FLV on xenon-enhanced ADCT and CT-based FLV significantly influenced GOLD classification (p < 0.0001). The diagnostic accuracy of the proposed model was significantly higher than that of ventilated FLV on SPECT/CT (p = 0.03) and WA% (p = 0.008). Xenon-enhanced ADCT is more effective than 81m Kr-ventilation SPECT/CT for the assessment of pulmonary functional loss and disease severity.

  20. Pulmonary CT findings in acute mercury vapour exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Manabu; Sato, Kimihiko; Heianna, Jyouiti; Hirano, Yoshinori; Omachi, Kohiti; Izumi, Jyunichi; Watarai, Jiro

    2001-01-01

    AIM: We describe the pulmonary computed tomography (CT) findings in acute mercury poisoning. MATERIALS AND METHODS: Initial (n= 8) and follow-up (n= 6) chest CT examinations in eight patients exposed to mercury vapour while cutting pipes in a sulphuric acid plant were reviewed. Of the eight patients, two were asymptomatic and had normal CT results, two were asymptomatic but had abnormalities on CT, and four had both acute symptoms and positive CT results. The patients were all men whose ages ranged from 37 to 54 years (mean, 49 years). RESULTS: Poorly defined nodules were present in five of six patients with positive CT findings, present alone in two patients or as part of a mixed pattern in three. They were random in distribution. Alveolar consolidation (n= 3) and areas of ground-glass opacity (n= 4) were observed and were more prominent in the most severely affected patients with the highest blood and urine level of mercury, predominantly in the upper and/or middle zone. These abnormal findings on CT resolved with (n= 1) or without (n= 5) steroid therapy. Pathological findings (n= 1) demonstrated acute interstitial changes predominantly with oedema. CONCLUSION: We report CT findings in eight patients acutely exposed to mercury vapour. The pulmonary injury was reversible on CT in these cases. Hashimoto, M. (2001)

  1. Assessing individual differences in proneness to shame and guilt: development of the Self-Conscious Affect and Attribution Inventory.

    Science.gov (United States)

    Tangney, J P

    1990-07-01

    Individual differences in proneness to shame and proneness to guilt are thought to play an important role in the development of both adaptive and maladaptive interpersonal and intrapersonal processes. But little empirical research has addressed these issues, largely because no reliable, valid measure has been available to researchers interested in differentiating proneness to shame from proneness to guilt. The Self-Conscious Affect and Attribution Inventory (SCAAI) was developed to assess characteristic affective, cognitive, and behavioral responses associated with shame and guilt among a young adult population. The SCAAI also includes indices of externalization of cause or blame, detachment/unconcern, pride in self, and pride in behavior. Data from 3 independent studies of college students and 1 study of noncollege adults provide support for the reliability of the main SCAAI subscales. Moreover, the pattern of relations among the SCAAI subscales and the relation of SCAAI subscales to 2 extant measures of shame and guilt support the validity of this new measure. The SCAAI appears to provide related but functionally distinct indices of proneness to shame and guilt in a way that these previous measures have not.

  2. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  3. CT and MR urography

    International Nuclear Information System (INIS)

    Hadjidekov, G.

    2012-01-01

    Full text: Learning objectives:1) To describe the techniques of CT Urography and of MR urography; 2) To illustrate the benefit of the methods in clinical practice; 3)To present typical cases from the daily practice CT has become the mainstay of uroradiology in adults. CT urography is an excellent technique for the evaluation of urinary tract calculi, trauma, infections, complicated cysts, renal masses, having high sensitivity and specificity for both conditions facilitated by the possibilities for multiplanar imaging of the urinary system. It resembles excretory urography and consists of unenhanced, nephrographic, and pyelographic phases and can be used even as routine investigation. MR urography is a new, modern modality for evaluation of various urological abnormalities providing both morphological and functional information by means of different sequences with or without injection of gadolinium. The method is clinically useful in the evaluation of the collecting system, various variants and congenital abnormalities of the kidney, different cases of obstruction of the excretory system, tumors and inflammatory processes, hematuria. Compared to CT urography, MR urography is particularly beneficial in pediatric group or pregnant patients. It can also be performed in patients with renal insufficiency, iodine allergy and other cases of contraindications to the use of ionizing radiation. CT and MR urography are promising diagnostic methods of the wide spectrum of pathological conditions affecting the urinary tract. They are highly informative and overcome a lot of limitations of the other imaging modalities with the potential to become leading modalities to diagnose kidney diseases and other urogenital disorders.

  4. Factors affecting assemblage attributes of freshwater Oligochaeta in Neotropical shallow floodplain lakes

    Directory of Open Access Journals (Sweden)

    Vanessa Ernandes de Amo

    2017-12-01

    Full Text Available Abstract Aim: Identify the effects of sediment composition and water conditions on diversity, richness, evenness, density and composition of freshwater Oligochaeta in shallow floodplain lakes. Methods We sampled 13 shallow floodplain lakes quarterly during the year 2010 in the Upper Paraná River floodplain. In each lake, four sediment samples were taken from the shore and central regions, three of them were used for biological analysis, and one for granulometric analysis. Concomitantly, temperature, dissolved oxygen, pH, conductivity, alkalinity, turbidity and chlorophyll-a were also measured. Initially, the biological samples were analyzed by a stereoscopic microscope. Oligochaeta individuals were identified under optical microscope at the lowest possible taxonomic level. For data analysis, we quantified density, richness, evenness and diversity index of freshwater Oligochaeta. In order to show differences between the months and the analyzed lakes, in relation to the percentages of coarse and fine organic material, the nonparametric Kruskal Wallis test was used. We also calculated the sediment granulometric diversity using the Shannon-Wienner index, using a simple regression analysis. We correlated assemblage attributes of Oligochaeta with sediment diversity and the assemblage species with the limnological variables using the Spearman correlation. Results A total of 2,090 individuals were found distributed among 27 species. From the total individuals number, 57% were Pristina americana, followed by Dero (Dero righii with 13%. Assemblage attributes were not significantly correlated with sediment diversity, and 7 of the 27 species recorded showed significant correlations with at least some of the abiotic variables. Conclusions We verified that the abiotic variables of the water present greater influence on the attributes of the assemblage of freshwater Oligochaeta, when compared with sediment influences. Although we found low local diversity of

  5. CT and MRI of the epigastrium - is the MRI competitive?

    International Nuclear Information System (INIS)

    Hamm, B. von

    1993-01-01

    The conclusion drawn in this article is: - CT will continue to rank first as a method for diagnostic evaluation of the entire abdomen. - MRI now offers advantages over CT for diagnostic identification of focal liver lesions, both with regard to detection as such and to a differential diagnosis of liver tumors. - CT continues to be the modality of first choice for diagnostic evaluation of acute pancreatitis. - CT offers advantages for the diagnostic evaluation of the gastrointestinal tract (as e.g. in case of complications in the course of inflammatory intestinal affection). - Interventional measures such as biopsies or abscess drainage will still be best controlled by CT, and MRI is not likely to become a really competitive method for such tasks in the foreseeable future. (orig.) [de

  6. Attribution of climate extreme events

    Science.gov (United States)

    Trenberth, Kevin E.; Fasullo, John T.; Shepherd, Theodore G.

    2015-08-01

    There is a tremendous desire to attribute causes to weather and climate events that is often challenging from a physical standpoint. Headlines attributing an event solely to either human-induced climate change or natural variability can be misleading when both are invariably in play. The conventional attribution framework struggles with dynamically driven extremes because of the small signal-to-noise ratios and often uncertain nature of the forced changes. Here, we suggest that a different framing is desirable, which asks why such extremes unfold the way they do. Specifically, we suggest that it is more useful to regard the extreme circulation regime or weather event as being largely unaffected by climate change, and question whether known changes in the climate system's thermodynamic state affected the impact of the particular event. Some examples briefly illustrated include 'snowmaggedon' in February 2010, superstorm Sandy in October 2012 and supertyphoon Haiyan in November 2013, and, in more detail, the Boulder floods of September 2013, all of which were influenced by high sea surface temperatures that had a discernible human component.

  7. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  8. Noncognitive Attributes in Physician Assistant Education.

    Science.gov (United States)

    Brenneman, Anthony E; Goldgar, Constance; Hills, Karen J; Snyder, Jennifer H; VanderMeulen, Stephane P; Lane, Steven

    2018-03-01

    Physician assistant (PA) admissions processes have typically given more weight to cognitive attributes than to noncognitive ones, both because a high level of cognitive ability is needed for a career in medicine and because cognitive factors are easier to measure. However, there is a growing consensus across the health professions that noncognitive attributes such as emotional intelligence, empathy, and professionalism are important for success in clinical practice and optimal care of patients. There is also some evidence that a move toward more holistic admissions practices, including evaluation of noncognitive attributes, can have a positive effect on diversity. The need for these noncognitive attributes in clinicians is being reinforced by changes in the US health care system, including shifting patient demographics and a growing emphasis on team-based care and patient satisfaction, and the need for clinicians to help patients interpret complex medical information. The 2016 Physician Assistant Education Association Stakeholder Summit revealed certain behavioral and affective qualities that employers of PAs value and sometimes find lacking in new graduates. Although there are still gaps in the evidence base, some tools and technologies currently exist to more accurately measure noncognitive variables. We propose some possible strategies and tools that PA programs can use to formalize the way they select for noncognitive attributes. Since PA programs have, on average, only 27 months to educate students, programs may need to focus more resources on selecting for these attributes than teaching them.

  9. The Link between HR Attributions and Employees’ Turnover Intentions

    Directory of Open Access Journals (Sweden)

    Juliana Caesaria Tandung

    2016-02-01

    Full Text Available Human Resources Management (HRM is part of the organizational functions that contribute to the effectiveness of a firm’s performance, and brings an organization a competitive advantage through the implementation of its Human Resources (HR practices. HR practices adopted by management are perceived or attributed subjectively by individual employees, and can in turn affect the employees’ attitudes and behavior (e.g. Job satisfaction and turnover intention. The purpose of this study is to contribute to the process-based approach by investigating the effect of HR attributions on turnover intentions, with job satisfaction playing a mediating role. The analysis is on the individual level, with 454 respondents from various organizations within the Netherlands. The results show that HR attributions can affect the turnover intention, through the presence of job satisfaction. Thus, it can be said that it is important to always consider the employees’ attitudes and behavior when examining their perception of HR practices, and in predicting their intention to leave.

  10. Arterio-venous anastomoses in mice affect perfusion measurements with dynamic contrast enhanced CT

    International Nuclear Information System (INIS)

    Gabra, Peter; Lee, Ting-Yim; Shen, Gang; Xuan, Jim

    2010-01-01

    Accurate measurement of perfusion with dynamic contrast enhanced CT requires an arterial input curve (AIC) uncontaminated by venous sources. Arterio-venous anastomoses (AVAs) are sources of contamination if contrast is injected intravenously. We seek to identify AVAs in mice and associated errors in perfusion measurements. Six transgenic mice with spontaneous prostate tumor were scanned with a micro-CT scanner (GE Healthcare (GE)) using a high resolution anatomical and a lower resolution perfusion protocol. For the anatomical protocol, a CT scan was performed during injection of an iodinated contrast agent (Hypaque) into a tail vein. Images covering the thoracic, abdominal and pelvic regions at an isotropic resolution of 175 µm were reconstructed and rendered in 3D to show the arterial and venous tree (Advantage Window, GE). For the perfusion protocol, each mouse was continuously scanned for 40 s and the contrast agent (Hypaque) was injected via a tail vein 5 s into scanning. Tumor images were reconstructed every second. Tumor blood flow (BF) and volume (BV) maps were calculated with CT perfusion software (GE) using AIC measured either from abdominal aorta (AA) or tail (caudal) artery (TA). In all mice, there was an AVA from the bifurcation of the inferior vena cava to the tail artery shunting venous blood and portion of the contrast agent injected into the tail vein into the TA. Contrast arrival time at the TA preceded that at the AA by 3.3 ± 0.5 s (P < 0.05). Mean tumor BV and BF values calculated with AA versus TA were 10.0 ± 1.8 versus 4.8 ± 2.1 ml (100 g) −1 (P < 0.05) and 108.8 ± 26.5 versus 33.0 ± 8.5 ml min −1 100 g −1 (P < 0.05), respectively. AVA in the murine pelvic region can result in inaccurate and more variable measurements of pelvic organ/tissue perfusion when the tail artery is used as the AIC

  11. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  12. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  13. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  14. Adaptive statistical iterative reconstruction improves image quality without affecting perfusion CT quantitation in primary colorectal cancer

    Directory of Open Access Journals (Sweden)

    D. Prezzi

    Full Text Available Objectives: To determine the effect of Adaptive Statistical Iterative Reconstruction (ASIR on perfusion CT (pCT parameter quantitation and image quality in primary colorectal cancer. Methods: Prospective observational study. Following institutional review board approval and informed consent, 32 patients with colorectal adenocarcinoma underwent pCT (100 kV, 150 mA, 120 s acquisition, axial mode. Tumour regional blood flow (BF, blood volume (BV, mean transit time (MTT and permeability surface area product (PS were determined using identical regions-of-interests for ASIR percentages of 0%, 20%, 40%, 60%, 80% and 100%. Image noise, contrast-to-noise ratio (CNR and pCT parameters were assessed across ASIR percentages. Coefficients of variation (CV, repeated measures analysis of variance (rANOVA and Spearman’ rank order correlation were performed with statistical significance at 5%. Results: With increasing ASIR percentages, image noise decreased by 33% while CNR increased by 61%; peak tumour CNR was greater than 1.5 with 60% ASIR and above. Mean BF, BV, MTT and PS differed by less than 1.8%, 2.9%, 2.5% and 2.6% across ASIR percentages. CV were 4.9%, 4.2%, 3.3% and 7.9%; rANOVA P values: 0.85, 0.62, 0.02 and 0.81 respectively. Conclusions: ASIR improves image noise and CNR without altering pCT parameters substantially. Keywords: Perfusion imaging, Multidetector computed tomography, Colorectal neoplasms, Computer-assisted image processing, Radiation dosage

  15. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  16. [Mobile CT at neurointensive sections--it is possible].

    Science.gov (United States)

    Frost, Majbritt; Stenkær, Susanne; Kellenberger, Simone; Ehlers, Lars

    2011-01-24

    Intrahospital transportation can be complicated and hazardous. Mobile computerized tomography (CT) of the head performed at the neurointensive care unit is a new technique that minimizes the need for transportation of unstable patients. Even small changes in physiological parameters can be detrimental for these patients and cause secondary injury and thus affect their prognoses. The portable CT scanner in the neurointensive care unit holds great potential, but the high price level may limit its use.

  17. Investigation of CT picture in so-called loose shoulder

    International Nuclear Information System (INIS)

    Kuroda, Shigehito; Sakamaki, Hiroshi; Matsuoka, Akira; Moriishi, Takeji; Takada, Keiichi.

    1985-01-01

    CT picture of the shoulder joint was analyzed in 124 shoulders (114 patients). A line perpendicular to a given line between the precornu of acetabular tegmen (A) and the postcornu of acetabular tegmen (B) was drawn and the intersection where the line and the caput humeri meet (C) was obtained. The angle of CAB was defined as the backward angular aperture of the acetabular tegmen. The angular aperture was 26.2 0 +-1.9 in 16 so-called loose shoulders, 17.3 0 +-1.0 in 28 loose shoulders restricted to the inward rotation, and 12.2 0 +-0.4 in 80 normal shoulders, showing a distinct correlation between the angular aperture and the degree of loose shoulder. An increased backward angular aperture of the acetabular tegmen was considered greatly attributable to the forward glenohumeral movement resulting from malformation of the acetabular tegmen and flaccidity of the joint. Glenoid osteotomy was thus performed in 9 patients, 6 of whom underwent CT scanning before and after osteotomy. Coronal and transverse CT images of the shoulder joint disclosed a noticeable improvement of the glenohumeral alignment. The angular aperture shown on CT seems to be of major importance not only in the diagnosis of so-called loose shoulder but also in surgical choice. (Namekawa, K.)

  18. The muscle CT of thigh in chronic Werdnig-Hoffmann disease

    International Nuclear Information System (INIS)

    Horikawa, Hirosei; Konagaya, Masaaki; Takayanagi, Tetsuya; Otsuji, Hideaki

    1986-01-01

    In this paper, the muscle CT of thigh in chronic Werdnig-Hoffmann disease (chronic WH) was evaluated. The subjects were five cases of chronic WH (3 males and 2 females, ages ranging from 6 to 22 years) and four control males. All cases showed symmetrical muscular weakness. The proximal muscle were more affected than the distal in the upper limbs. But the muscle strength of hip adduction was relatively spared as compared with other strength of lower limbs. The CT scan was carried out at the upper quarter level between lesser trochanter and medial condyle of the femur. The muscle CT of cases aged 6 and 7 years showed the severely decreased cross-sectional area of muscle without significant decrease in density. The atrophic muscles were surrounded by a large amount of low density area. The hamstring muscles and the adductor muscles, especially adductor longus muscle (ALM), were less affected than the quadriceps femoris muscles. Spotty and moth-eaten low density areas were observed dominantly in the severely affected muscles. In the advanced cases, only ALM could be identified on the CT image. The other muscles were unable to be identified because of severe atrophy with extremely low density. These CT findings suggest the process of muscular wastings of chronic WH as follows; at first muscle fibers are atrophied due to denervation and sooner or later replaced with fat tissue. Moreover, the preservation of ALM suggests that loss of anterior horn cells does not always go on homogeneously. (author)

  19. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  20. Secondary School Mathematics Student Teachers' Causal Attribution for Success and Failure in Mathematics

    Science.gov (United States)

    Savas Basturk

    2016-01-01

    Attribution theory deals with the question of how individuals make judgments and seek to explain how they consider the causes of their behaviours and those of others. Attributions have the potential to affect beliefs, emotions and behaviour. Therefore, attribution theory has significantly contributed to the studies on motivation. This study…

  1. Structural Measures to Track the Evolution of SNOMED CT Hierarchies

    Science.gov (United States)

    Wei, Duo; Gu, Huanying (Helen); Perl, Yehoshua; Halper, Michael; Ochs, Christopher; Elhanan, Gai; Chen, Yan

    2015-01-01

    The Systematized Nomenclature of Medicine Clinical Terms (SNOMED CT) is an extensive reference terminology with an attendant amount of complexity. It has been updated continuously and revisions have been released semi-annually to meet users’ needs and to reflect the results of quality assurance (QA) activities. Two measures based on structural features are proposed to track the effects of both natural terminology growth and QA activities based on aspects of the complexity of SNOMED CT. These two measures, called the structural density measure and accumulated structural measure, are derived based on two abstraction networks, the area taxonomy and the partial-area taxonomy. The measures derive from attribute relationship distributions and various concept groupings that are associated with the abstraction networks. They are used to track the trends in the complexity of structures as SNOMED CT changes over time. The measures were calculated for consecutive releases of five SNOMED CT hierarchies, including the Specimen hierarchy. The structural density measure shows that natural growth tends to move a hierarchy’s structure toward a more complex state, whereas the accumulated structural measure shows that QA processes tend to move a hierarchy’s structure toward a less complex state. It is also observed that both the structural density and accumulated structural measures are useful tools to track the evolution of an entire SNOMED CT hierarchy and reveal internal concept migration within it. PMID:26260003

  2. Effects of attribute framing on cognitive processing and evaluation

    OpenAIRE

    Kuvaas, Bård; Selart, Marcus

    2004-01-01

    Whereas there is extensive documentation that attribute framing influences the content of people’s thought, we generally know less about how it affects the processes assumed to precede those thoughts. While existing explanations for attribute framing effects rely completely on valence-based associative processing, the results obtained in the present study are also consistent with the notion that negative framing stimulates more effortful and thorough information processing than positive frami...

  3. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  4. Accurate corresponding point search using sphere-attribute-image for statistical bone model generation

    International Nuclear Information System (INIS)

    Saito, Toki; Nakajima, Yoshikazu; Sugita, Naohiko; Mitsuishi, Mamoru; Hashizume, Hiroyuki; Kuramoto, Kouichi; Nakashima, Yosio

    2011-01-01

    Statistical deformable model based two-dimensional/three-dimensional (2-D/3-D) registration is a promising method for estimating the position and shape of patient bone in the surgical space. Since its accuracy depends on the statistical model capacity, we propose a method for accurately generating a statistical bone model from a CT volume. Our method employs the Sphere-Attribute-Image (SAI) and has improved the accuracy of corresponding point search in statistical model generation. At first, target bone surfaces are extracted as SAIs from the CT volume. Then the textures of SAIs are classified to some regions using Maximally-stable-extremal-regions methods. Next, corresponding regions are determined using Normalized cross-correlation (NCC). Finally, corresponding points in each corresponding region are determined using NCC. The application of our method to femur bone models was performed, and worked well in the experiments. (author)

  5. Three-dimensional multislice CT imaging of otitis media

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro; Wada, Akihiro; Ando, Ichiro

    2002-01-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  6. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  7. Prospective evaluation of MRI, 11C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    International Nuclear Information System (INIS)

    Vargas, H.A.; Akin, O.; Schöder, H.; Olgac, S.; Dalbagni, G.; Hricak, H.; Bochner, B.H.

    2012-01-01

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11 C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11 C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11 C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, 11 C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  8. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  9. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  10. Developing optimized CT scan protocols: Phantom measurements of image quality

    International Nuclear Information System (INIS)

    Zarb, Francis; Rainford, Louise; McEntee, Mark F.

    2011-01-01

    Purpose: The increasing frequency of computerized tomography (CT) examinations is well documented, leading to concern about potential radiation risks for patients. However, the consequences of not performing the CT examination and missing injuries and disease are potentially serious, impacting upon correct patient management. The ALARA principle of dose optimization must be employed for all justified CT examinations. Dose indicators displayed on the CT console as either CT dose index (CTDI) and/or dose length product (DLP), are used to indicate dose and can quantify improvements achieved through optimization. Key scan parameters contributing to dose have been identified in previous literature and in previous work by our group. The aim of this study was to optimize the scan parameters of mA; kV and pitch, whilst maintaining image quality and reducing dose. This research was conducted using psychophysical image quality measurements on a CT quality assurance (QA) phantom establishing the impact of dose optimization on image quality parameters. Method: Current CT scan parameters for head (posterior fossa and cerebrum), abdomen and chest examinations were collected from 57% of CT suites available nationally in Malta (n = 4). Current scan protocols were used to image a Catphan 600 CT QA phantom whereby image quality was assessed. Each scan parameter: mA; kV and pitch were systematically reduced until the contrast resolution (CR), spatial resolution (SR) and noise were significantly lowered. The Catphan 600 images, produced by the range of protocols, were evaluated by 2 expert observers assessing CR, SR and noise. The protocol considered as the optimization threshold was just above the setting that resulted in a significant reduction in CR and noise but not affecting SR at the 95% confidence interval. Results: The limit of optimization threshold was determined for each CT suite. Employing optimized parameters, CTDI and DLP were both significantly reduced (p ≤ 0.001) by

  11. Range and nummer-of-levels effects in derived and stated attribute importances

    NARCIS (Netherlands)

    Verlegh, P.W.J.; Schifferstein, H.N.J.; Wittink, D.R.

    2002-01-01

    We study how the range of variation and the number of ttribute levels affect five measures of attribute importance: full profile conjoint estimates, ranges in attribute level attractiveness ratings. regression coefficients. graded paired comparisons. and self-reported ratings, We find that all

  12. CT study of intracionial Wegener's Granulomatosis

    International Nuclear Information System (INIS)

    Yago, M.D.; Torres, T.; Martinez, G.; Lopez, A.; Barrena, R.

    1995-01-01

    Wegener granulamatosis is a multi systemic necrotizing granulomatous vasculitis distinguished from others by its predilection to affect the respiratory tract and the kidneys. Nervous system involvement occurs in 25% of cases, and the most common neurological manifestation is mono neuritis multiplex. However, primary affectation of CNS in an unusual manifestation. We report a case of Wegener Granulomatosis with almost unique neurological manifestation. CT imaging findings of meningeal involvement and retro-orbital pseudotumor are presented. 12 refs

  13. Age-related changes to spectral voice characteristics affect judgments of prosodic, segmental, and talker attributes for child and adult speech

    Science.gov (United States)

    Dilley, Laura C.; Wieland, Elizabeth A.; Gamache, Jessica L.; McAuley, J. Devin; Redford, Melissa A.

    2013-01-01

    Purpose As children mature, changes in voice spectral characteristics covary with changes in speech, language, and behavior. Spectral characteristics were manipulated to alter the perceived ages of talkers’ voices while leaving critical acoustic-prosodic correlates intact, to determine whether perceived age differences were associated with differences in judgments of prosodic, segmental, and talker attributes. Method Speech was modified by lowering formants and fundamental frequency, for 5-year-old children’s utterances, or raising them, for adult caregivers’ utterances. Next, participants differing in awareness of the manipulation (Exp. 1a) or amount of speech-language training (Exp. 1b) made judgments of prosodic, segmental, and talker attributes. Exp. 2 investigated the effects of spectral modification on intelligibility. Finally, in Exp. 3 trained analysts used formal prosody coding to assess prosodic characteristics of spectrally-modified and unmodified speech. Results Differences in perceived age were associated with differences in ratings of speech rate, fluency, intelligibility, likeability, anxiety, cognitive impairment, and speech-language disorder/delay; effects of training and awareness of the manipulation on ratings were limited. There were no significant effects of the manipulation on intelligibility or formally coded prosody judgments. Conclusions Age-related voice characteristics can greatly affect judgments of speech and talker characteristics, raising cautionary notes for developmental research and clinical work. PMID:23275414

  14. Retrospective data-driven respiratory gating for PET/CT

    International Nuclear Information System (INIS)

    Schleyer, Paul J; O'Doherty, Michael J; Barrington, Sally F; Marsden, Paul K

    2009-01-01

    Respiratory motion can adversely affect both PET and CT acquisitions. Respiratory gating allows an acquisition to be divided into a series of motion-reduced bins according to the respiratory signal, which is typically hardware acquired. In order that the effects of motion can potentially be corrected for, we have developed a novel, automatic, data-driven gating method which retrospectively derives the respiratory signal from the acquired PET and CT data. PET data are acquired in listmode and analysed in sinogram space, and CT data are acquired in cine mode and analysed in image space. Spectral analysis is used to identify regions within the CT and PET data which are subject to respiratory motion, and the variation of counts within these regions is used to estimate the respiratory signal. Amplitude binning is then used to create motion-reduced PET and CT frames. The method was demonstrated with four patient datasets acquired on a 4-slice PET/CT system. To assess the accuracy of the data-derived respiratory signal, a hardware-based signal was acquired for comparison. Data-driven gating was successfully performed on PET and CT datasets for all four patients. Gated images demonstrated respiratory motion throughout the bin sequences for all PET and CT series, and image analysis and direct comparison of the traces derived from the data-driven method with the hardware-acquired traces indicated accurate recovery of the respiratory signal.

  15. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-02-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author).

  16. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    International Nuclear Information System (INIS)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-01-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author)

  17. Learned Helplessness: Shifts in Affect Following Uncontrollability and the Relationship to Attributional Style.

    Science.gov (United States)

    Bauer, Allison

    This study investigated the reformulated theory of learned helplessness, centering around attributional style in the cause of cognitive and emotional deficits. Subjects (N=58) were undergraduate and graduate psychology students at the University of Alabama at Huntsville. Subjects were divided into an experimental group (N=30) who received…

  18. Prospective evaluation of MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT for staging of bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, H.A., E-mail: vargasah@mskcc.org [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Akin, O.; Schöder, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Olgac, S. [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Dalbagni, G. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hricak, H. [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Bochner, B.H. [Department of Surgery, Urology Service, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-12-15

    Purpose: To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), {sup 11}C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard. Materials and methods: The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, {sup 11}C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality. Results: MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, {sup 11}C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy. Conclusion: In staging bladder cancer, MRI, {sup 11}C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.

  19. Studying consumer behaviour related to the quality of food: A case on vegetable preparation affecting sensory and health attributes

    NARCIS (Netherlands)

    Bongoni, R.; Steenbekkers, L.P.A.; Verkerk, R.; Boekel, van M.A.J.S.; Dekker, M.

    2013-01-01

    The domestic preparation of vegetables induces a significant change in their sensory and health attributes. The preparation of vegetables by consumers is likely to be controlled by assessing perceivable (sensory) quality attributes such as colour and texture because other quality attributes,

  20. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  1. Radiation dose-reduction strategies in thoracic CT.

    Science.gov (United States)

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Public’s Attribution vs Punitive Behavior in Indonesian Public Relations Practice

    Directory of Open Access Journals (Sweden)

    Rachmat Kriyantono

    2017-06-01

    Full Text Available The research aims to test situational crisis communication and attribution theories in Indonesian context. Crisis threats companies’ reputation and affects the public’s attribution which will lead to the creation of punitive behavior from the public towards the organization. The study used a quantitative approach with experimental method and content analysis in the pre-research. Involving 90 respondents, the research fi nds that mass media infl uences public’s attribution within the experimental group who were given positive and negative news. The research shows that the crisis history and the relational reputation determine the public attribution toward the initial crisis responsibility.

  3. Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Schreyer, A.G.; Jung, E.M.; Heiss, P.; Zorger, N. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schreyer, C.I.; Framme, C. [Klink und Poliklinik fuer Augenheilkunde, Universitaetsklinikum Regensburg (Germany)

    2010-02-15

    Purpose: To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries. Materials and Methods: Based on a retrospective chart review between 2002 and 2007, we identified 59 patients presenting with severe ocular trauma with uncertain rupture of the globe due to massive subconjunctival and/or anterior chamber hemorrhage. The IOP (intraocular pressure) was within normal range in all patients. High resolution multidetector CT (MD-CT) scans (16 slice scans) with axial and coronar reconstructions were performed in all patients. The affected eye was examined for signs of penetrating injury such as abnormal eye shape, scleral irregularities, lens dislocation or intravitreal hemorrhages. Four experienced radiologists read the CT scans independently. Beside the diagnosis, the relevant morphological criteria and the optimal plane orientation (axial or coronar) were specified. The sensitivity, specificity, and negative and positive predictive value were calculated. Additionally the interobserver variability was determined by applying the Cohen's kappa test. Surgical sclera inspections were performed in all cases as a standard of reference. The evaluations of the CT examination were compared with the surgery reports. Results: 59 patients were evaluated (42 men, 17 women). The mean age was 29 years (range 7-91). In 17 patients a rupture of the globe was diagnosed during surgery. 12 of these 17 penetrating injuries (70.6%) were classified correctly by MDCT, 5 of the 17 (29.4%) were not detectable. 42 patients did not have an open globe injury. 41 of these patients were diagnosed correctly negative by MDCT, and one patient was classified false positive. This results in a sensitivity of 70% with a specificity of 98%. There was high inter-rater agreement with kappa values between 0.89-0.96. Most discrepancies were caused by wrong negative findings. The most frequent morphologic criteria for open globe injury were the deformation (n

  4. Chest CT findings in pediatric Wegener's granulomatosis

    International Nuclear Information System (INIS)

    Levine, Daniel; Akikusa, Jonathan; Manson, David; Silverman, Earl; Schneider, Rayfel

    2007-01-01

    Although pulmonary involvement occurs in the majority of children and adolescents with Wegener's granulomatosis (WG), relatively little has been published regarding the CT imaging manifestations in this group of patients. To determine the frequency and types of chest CT abnormalities in active pediatric WG (pWG). The study was a retrospective examination of 29 chest CT examinations performed at diagnosis (n=14) and during disease flares (n=15) in 18 children. The most common abnormalities were nodules (seen in 90% of examinations), ground-glass opacification (52%), and air-space opacification (45%). Of examinations with nodules, 73% demonstrated nodules >5 mm in diameter and 69% demonstrated more than five nodules; 17% had cavitary lesions. The only abnormality with a significant difference in prevalence between diagnosis and disease flares was air-space opacification, present in 71% and 20%, respectively (P < 0.01). In accordance with the findings of published adult studies and at variance with those of prior pediatric studies, our findings indicate that chest CT abnormalities in active pWG are frequent, most commonly comprising nodules and ground-glass opacification, which may be difficult to detect on plain radiography. We therefore advocate the routine use of chest CT for all affected patients, both at the time of presentation and during disease flares. (orig.)

  5. FDG-PET/CT Imaging for Staging and Target Volume Delineation in Preoperative Conformal Radiotherapy of Rectal Cancer

    International Nuclear Information System (INIS)

    Bassi, Maria Chiara; Turri, Lucia; Sacchetti, Gianmauro; Loi, Gianfranco; Cannillo, Barbara; La Mattina, Pierdaniele; Brambilla, Marco; Inglese, Eugenio; Krengli, Marco

    2008-01-01

    Purpose: To investigate the potential impact of using 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on staging and target volume delineation for patients affected by rectal cancer and candidates for preoperative conformal radiotherapy. Methods and Materials: Twenty-five patients diagnosed with rectal cancer T3-4 N0-1 M0-1 and candidates for preoperative radiotherapy underwent PET/CT simulation after injection of 5.18 MBq/kg of FDG. Clinical stage was reassessed on the basis of FDG-PET/CT findings. The gross tumor volume (GTV) and the clinical target volume (CTV) were delineated first on CT and then on PET/CT images. The PET/CT-GTV and PET/CT-CTV were analyzed and compared with CT-GTV and CT-CTV, respectively. Results: In 4 of 25 cases (24%), PET/CT affected tumor staging or the treatment purpose. In 3 of 25 cases (12%) staged N0 M0, PET/CT showed FDG uptake in regional lymph nodes and in a case also in the liver. In a patient with a single liver metastasis PET/CT detected multiple lesions, changing the treatment intent from curative to palliative. The PET/CT-GTV and PET/CT-CTV were significantly greater than the CT-GTV (p = 0.00013) and CT-CTV (p = 0.00002), respectively. The mean difference between PET/CT-GTV and CT-GTV was 25.4% and between PET/CT-CTV and CT-CTV was 4.1%. Conclusions: Imaging with PET/CT for preoperative radiotherapy of rectal cancer may lead to a change in staging and target volume delineation. Stage variation was observed in 12% of cases and a change of treatment intent in 4%. The GTV and CTV changed significantly, with a mean increase in size of 25% and 4%, respectively

  6. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    International Nuclear Information System (INIS)

    El-Badrawy, Adel; Zeidan, Amany; Ebrahim, Mohamed A.

    2012-01-01

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection

  7. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    El-Badrawy, Adel [Dept. of Radiology, Mansoura Faculty of Medicine, Mansoura (Egypt)], E-mail: adelelbadrawy@hotmail.com; Zeidan, Amany [Dept. of Thoracic Medicine, Mansoura Faculty of Medicine, Mansoura (Egypt); Ebrahim, Mohamed A. [Dept. of Medical Oncology, Mansoura Faculty of Medicine, Mansoura (Egypt)

    2012-07-15

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection.

  8. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  9. Computerized tomography data on CNS affection in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Ivanova, M.M.; Bliznyuk, O.I.; Todua, F.I.; Tumanova, A.A.

    1989-01-01

    Computed tomography (CT) of the brain was employed in 40 patients with systemic lupus erythematosus (SLE). Clinical cerebral pathology was obvious in 30 and absent in 10 patients. By CT cerebral symptoms were divided of 4 groups. Clinical symptom complexes of CNS defects and SLE were reflected on definite CT images correlated with focal damage to the brain. CT picture of enlarged subarachnoid space, ventricles and basal cisterns can be observed in SLE patients without neurological symptoms. This indicated likely subclinical cerebral affection

  10. Discourse Model Representation of Referential and Attributive Descriptions.

    Science.gov (United States)

    Onishi, Kristine H.; Murphy, Gregory L.

    2002-01-01

    Manipulated shared knowledge and focus on specific entities, the verb in the sentence, and whether the description was definite or indefinite. Each factor influenced interpretation of the description. Confirmed that changing verbs alone affected reference choice. Indicated that both referentially and attributively introduced entities are…

  11. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R.; McNeel, Sandra V. [Environmental Health Investigations Branch, California Department of Public Health, Richmond, CA (United States); Cohen, Ronald A. [Children' s Hospital and Research Center Oakland, Department of Radiology, Oakland, CA (United States)

    2014-05-15

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care. (orig.)

  12. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities

    International Nuclear Information System (INIS)

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R.; McNeel, Sandra V.; Cohen, Ronald A.

    2014-01-01

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care. (orig.)

  13. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  14. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

    Science.gov (United States)

    Burger, C; Goerres, G; Schoenes, S; Buck, A; Lonn, A H R; Von Schulthess, G K

    2002-07-01

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.

  15. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  16. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias; Scholz, Bernhard; Royalty, Kevin

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  17. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  18. The “Depressive” Attributional Style Is Not That Depressive for Buddhists

    Directory of Open Access Journals (Sweden)

    Michelle T. Liu

    2017-06-01

    Full Text Available Numerous studies have shown that depression-prone people are characterized by a chronic style of attributing failures to internal, stable, and global causes, sometimes labeled as the “depressive attributional style.” Much less is known, however, about how social-cultural factors such as religious beliefs might modulate these processes. In the current study, we hypothesized that Buddhism’s view of ultimate internal controllability plays a buffering role against the depressive attributional style and reduces its negative impacts. We administrated measures of attributional styles and psychological adjustments to a sample of Chinese Buddhists as well as a control group recruited in China. Data analyses showed that Buddhists were more likely to attribute bad outcomes to internal, stable, and global causes, but their well-being was less affected by it. Thus, these results indicate that the “depressive” attributional style is not that depressive for Buddhists, after all.

  19. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  20. CT findings in autoimmune pancreatitis: assessment using multiphase contrast-enhanced multisection CT

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K., E-mail: Kojiro@med.nagoya-u.ac.j [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Nagoya Hirokoji Clinic, Nagoya (Japan); Nagasaka, T. [Departments of Medical Technology, Nagoya University School of Health Science, Nagoya (Japan); Ogawa, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2010-09-15

    Aim: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). Materials and methods: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. Results: The pancreas showed diffuse enlargement (n = 16; 32%), focal enlargement (n = 18; 36%), or no enlargement (n = 16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n = 45; 90%) and hyperattenuation during the delayed phase (n = 39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n = 24; 48%); no visualization of the main pancreatic duct lumen (n = 48; 96%); ductal enhancement (n = 26; 52%); upstream dilatation of the main pancreatic duct (n = 27; 54%); upstream atrophy of the pancreatic parenchyma (n = 27; 54%); calcification (n = 7; 14%); and cysts (n = 5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n = 40; 80%); peripancreatic (n = 8; 16%) or para-aortic (n = 10; 20%) soft-tissue proliferation; and renal involvement (n = 15; 30%). Conclusion: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.

  1. The role of instrumental, hedonic and symbolic attributes in the intention to adopt electric vehicles

    DEFF Research Database (Denmark)

    Schuitema, Geertje; Anable, Jillian; Skippon, Stephen

    2013-01-01

    The aim is to understand how private car drivers’ perception of vehicle attributes may affect their intention to adopt electric vehicles (EVs). Data are obtained from a national online survey of potential EV adopters in the UK. The results indicate that instrumental attributes are important largely...... to have positive perceptions of EV attributes. Perceptions of EV attributes are only very weakly associated with car-authority identity....

  2. Estimation of enhanced cancer risk with 18FDG PET/CT investigations

    International Nuclear Information System (INIS)

    Kaushik, Aruna; Mishra, Anil K.; Sharma, Rajnish; Mondal, Anupam; Dwarakanath, B.S.

    2014-01-01

    18 F-Fluorodeoxyglucose ( 18 FDG) Positron Emission Tomography/Computed Tomography (PET/CT) investigation involves internal administration of 18 FDG and use of CT X-rays for the purpose of obtaining functional and anatomical information of a patient. However, the radiation exposure from undergoing PET/CT investigation may enhance the risk of cancer incidence as per the Linear-No-Threshold (LNT) model. The objective of the present study was to quantify the risk of cancer incidence associated with radiation exposure from 18 FDG PET/CT investigations. The organ doses from internally administered 18 FDG were estimated using OLINDA/EXM Code by performing dynamic PET scans in different regions of the body in a total of forty-nine patients. Organ doses from the CT component were calculated using the software CT-Expo. The associated cancer risk was calculated in terms of life time risk of cancer incidence resulting from a specified dose of ionizing radiation and was expressed in terms of Lifetime Attributable Risk (LAR). LAR values and the organ doses estimated for males and females were used to estimate the lifetime risk of cancer incidence from whole body 18 FDG PET/CT scan. Since from 18 FDG whole body PET/CT investigations, various tissues of the body receive substantially different doses, the site specific risk of cancer incidence was estimated and summed to obtain the total risk. This was compared with the baseline lifetime risk of cancer incidence in Indian population. LAR of cancer incidence was observed to be relatively higher in females as compared to males. The risk estimates ranged from 0.36% to 0.49% for a 20 year old male and 0.58% to 0.79% for a 20 year old female and were observed to be higher in younger ages and decreased with age. 18 FDG whole body PET/CT investigation was observed to be associated with non-negligible radiation risk as compared to the risks associated with other diagnostic modalities. (author)

  3. Influences of packaging attributes on consumer purchase decisions for fresh produce.

    Science.gov (United States)

    Koutsimanis, Georgios; Getter, Kristin; Behe, Bridget; Harte, Janice; Almenar, Eva

    2012-10-01

    Packaging attributes are considered to have an influence on consumer purchase decisions for food and, as a consequence, also on its consumption. To improve the current minimal understanding of these influences for fresh produce, a survey instrument in the form of an online questionnaire has been developed and launched in the US. The first part of the questionnaire covers consumers' preferences for packaging convenience features, characteristics, materials, disposal method, and others for fresh produces in general, and the second focuses on attributes like price, container size, produce shelf life for a specific fresh produce, sweet cherries, to allow us to supply specific values for these factors to the participants. Cluster and conjoint analyses of responses from 292 participants reveal that specific packaging and produce attributes affect consumer purchase decisions of fresh produce in general and of sweet cherries in particular (P ≤ 0.05) and that some are population segment dependent (P ≤ 0.05). For produce packaging in general, 'extend the "best by" date' was ranked as the top convenience feature, the type of packaging material was considered to affect the food product quality (92.7%) and containers made from bio-based materials were highly appealing (3.52 out of 5.00). The most important attributes that affect the purchasing decisions of consumers regarding a specific fresh produce like sweet cherries are price (25%), shelf life (19%) and container size (17.2%). Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Linking hearts and minds in couple interactions: intentions, attributions, and overriding sentiments.

    Science.gov (United States)

    Waldinger, Robert J; Schulz, Marc S

    2006-09-01

    This study examined the role of emotion and relationship satisfaction in shaping attributions about a partner's intentions in couple interactions. Using video recall, participants (N = 156 couples) reported on their own and their partner's intentions and emotions during affective moments of a discussion about an upsetting event. Links were found between relationship satisfaction and factor-analytically derived intention and attribution scales. Attributions about a partner's intentions were weakly to moderately correlated with the partner's self-reported intentions. Relationship satisfaction accounted for part of the discrepancy between self-reported intentions and partner attributions. Emotions mediated the links between relationship satisfaction and attributions, suggesting that clinicians working with distressed couples should pay more attention to the emotional climate in which attributions are made. Copyright (c) 2006 APA, all rights reserved.

  5. An Attributional Theory of Achievement Motivation and Emotion.

    Science.gov (United States)

    Weiner, Bernard

    1985-01-01

    This article advances an attributional theory of motivation and emotion, with achievement strivings as the theoretical focus. Causes of success and failure share three common properties: locus, stability, and controllability. Stability of causes influences changes in expectancy of success. Expectancy and affect guide motivated behavior.…

  6. How to perform dosimetry with Optical CT

    International Nuclear Information System (INIS)

    Wuu, Cheng-Shie; Xu, Y

    2010-01-01

    Both polymer gels and PRESAGE radiochromic solid dosimeter, in conjunction with optical CT scanning system, have been employed to measure 3-D dose distribution. The 3-D dose maps obtained from these systems can provide a useful tool for dose verification on complex treatments such as IMRT, radiosurgery, and RapidArc. These complex treatments present high dose gradient regions in the boundaries between the target and the surrounding critical organs. Dose accuracy in these areas can be critical, and may affect the treatment. There is a pressing need for a dosimeter that allows for accurate determination of 3-D dose distribution with high spatial resolution. In this paper, performance of polymer gels and PRESAGE dosimeter with optical CT scanning is reviewed and evaluated in terms of their sensitivity calibration, irradiation, optimization of scanning procedures, precision, and accuracy. Clinical applications of optical-CT dosimetry are presented.

  7. First experience with early dynamic 18F-NaF-PET/CT in patients with chronic osteomyelitis

    International Nuclear Information System (INIS)

    Freesmeyer, M.; Stecker, F.F.; Schierz, J.-H.; Winkens, T.; Hofmann, G.O.

    2014-01-01

    This study investigates whether early dynamic positron emission tomography/computed tomography (ed-PET/CT) using 18 F-sodium fluoride-( 18 F-NaF) is feasible in depicting early phases of radiotracer distribution in patients with chronic osteomyelitis (COM). A total of 12 ed 18 F-NaF-PET/CT examinations were performed on 11 consecutive patients (2 female, 9 male; age 53 ± 12 years) in list mode over 5 min starting with radiopharmaceutical injection before standard late 18 F-NaF-PET/CT. Eight consecutive time intervals (frames) were reconstructed for each patient: four 15 s, then four 60 s. Several volumes of interest (VOI) were selected, representing the affected area as well as different reference areas within the bone and soft tissue. Maximum and mean ed standardized uptake values (edSUV max , edSUV mean , respectively) were calculated in each VOI during each frame to measure early fluoride influx and accumulation. Results were compared between affected and non-affected (contralateral) bones. Starting in the 31-45 s frame, the affected bone area showed significantly higher edSUV max and edSUV mean compared to the healthy contralateral region. The affected bone areas also significantly differed from non-affected contralateral regions in conventional late 18 F-NaF-PET/CT. This pilot study suggests that, in patients with COM, ed 18 F-NaF-PET offers additional information about early radiotracer distribution to standard 18 F-NaF-PET/CT, similar to a three-phase bone scan. The results should be validated in larger trials which directly compare ed 18 F-NaF-PET to a three-phase bone scan. (author)

  8. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  9. Volumetric dynamic contrast enhanced Computed Tomography (DCE-CT) for preoperative assessment of the vascularity of spinal metastases

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl

    Purpose To investigate the feasibility of measuring and grading the vascularity of spinal metastases using dynamic contrast enhanced CT (DCE-CT). Materials and methods Prior to surgical treatment of symptomatic metastatic spinal cord compression, 20 patients were examined using DCE-CT. The 320......–detector row CT scanner allowed a volumetric acquisition over a range of 16 cm, covering three to four vertebrae. Image analysis was performed at a dedicated workstation, encompassing quantitative and qualitative measurement of the arterial flow (AF) in mL/min/100mL of the vertebrae. The perfusion values...... were analysed using a single input, maximum slope model. The AF assessed by DCE-CT of affected and non-affected vertebrae will be compared, and furthermore, the correlation between AF and intraoperative blood loss will be examined. Results Preliminary results for 5 patients: In two patients the AF...

  10. Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact

    International Nuclear Information System (INIS)

    Choi, Ji Hun; Park, Jin Hong; Choi, Byung Don; Won, Hui Su; Chang, Nam Jun; Goo, Jang Hyun; Hong, Joo Wan

    2014-01-01

    This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, 15x15cm 2 and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers

  11. Anatomy of British Business School Brands: Attributes Affecting Choice Among Pakistani Postgraduate Students

    Directory of Open Access Journals (Sweden)

    Usman Ahmad

    2014-06-01

    Full Text Available The research studies that investigate business school brands from an Asian consumer perspective are scarce. Current study aims at discovering the branding attributes of UK Business Schools that influence Pakistani business students to apply for admission in higher degrees. Following a naturalistic tradition, data has been collected through semi-structured interviews from a sample of 25 students who were planning to study in United Kingdom. The respondents were identified through personal sources and were later selected using the purposive sampling technique. Thematic analysis was performed to generate themes from the collected data. The data analysis generated four dominant themes that influence the choice of a business school in United Kingdom. These are “financial assistance”, “employability”, “brand reputation” and “rankings”. The study is a pioneer work in the field of university branding from a developing country perspective of Pakistan. The research will be useful to British higher education marketers in devising student-centered branding initiatives. It will also benefit the Pakistani academia, as the country can develop business school brands as well by imparting these attributes to better compete with business schools in UK.

  12. [Detection of marginal leakage of Class V restorations in vitro by micro-CT].

    Science.gov (United States)

    Gu, Lin-juan; Zhao, Xin-yi; Li, Shi-bao

    2012-09-01

    To evaluate the reliability and superiority of micro-CT in marginal leakage assessment of Class V restorations. Class V preparations with gingival margins in dentin and occlusal in enamel were made in sixteen extracted non-carious human molars and restored with dental bonding agents and composite resin. All teeth were then immersed in 50% ammonia-silver nitrate solution for 12 hours, followed by developing solution for 8 hours. Each restoration was scanned by a micro-CT and silver leakage was measured and three-dimensional image of the silver leakage alone cavity wall were reconstructed. Afterward, all restorations were sectioned and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by micro-CT and microscope were compared for equivalency. The silver leakage depths in gingival wall obtained with micro-CT (0.78 mm) and microscope (0.74 mm) showed no significant difference (P > 0.05), while the judgment of leakage depths in occlusal wall in micro-CT image (0.40 mm) was affected by adjacent enamel structure, giving less leakage depths compared to microscope (0.72 mm)(P leakages showed channels on their way to spreading. Micro-CT can detect precisely the silver leakage in the dentin wall of a restoration and display its three-dimensional shape fully. Enamel structure affects the detection of the silver leakage next to it.

  13. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  14. Clinical data and CT findings of pulmonary infection caused by different pathogens after kidney transplantation

    International Nuclear Information System (INIS)

    Jiang Tao; Xue Feng; Zheng Xuan; Yu Hong; Tao Xiaofeng; Xiao Xiangsheng; Liu Shiyuan

    2012-01-01

    Purpose: The overall objective was to review clinical data and CT findings of pulmonary infection caused by different pathogens after kidney transplantation in an attempt to help early clinical qualitative diagnosis. Materials and methods: 446 cases of clinically confirmed pulmonary infection after kidney transplantation in recent 10 years were evaluated with respect to the time of occurrence and 89 cases with complete CT data and pathogenic diagnosis were further analyzed for pathogen types and CT manifestations. Statistical analysis was performed using Fisher's exact test. Results: Pulmonary infection reached the peak in 3 months after transplantation. Bacterial infection and mixed infection were predominant between 1 and 6 months. And most tuberculosis occurred after one year. Bacterial (38.2%) and mixed infections (38.2%) were the common types. The next was fungal infection, tuberculosis and viral infection (10.1%, 7.9% and 5.6%, respectively). CT manifestations of pulmonary infections after kidney transplantation were diverse and complex, lacking characteristic signs. Conclusion: More than 3/4 of pulmonary infections after kidney transplantation can be attributed to bacteria and mixed pathogens. The combination of time course, clinical data and CT manifestations plays an important role in the early clinical qualitative diagnosis.

  15. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  16. Skeletal metastasis as detected by 18F-FDG PET with negative CT of the PET/CT: Frequency and impact on cancer staging and or management

    Directory of Open Access Journals (Sweden)

    Fatma Ahmed

    2016-10-01

    Full Text Available Objectives: The aim of our study is to assess the frequency of detection of PET positive CT negative skeletal metastases (SM and determine the impact of such detection on staging and/or management in patients who had FDG PET/CT as part of the cancer work up.Methods: We retrospectively reviewed 2000 18F-FDG PET/CT scans of known cancer patients. A log was kept to record cases of suspected SM with or without bone changes from the low-dose non-contrast CT. The presence or absence of SM was evaluated based on available pathological and clinical data. The impact of detection of such lesions on cancer staging and/or management was evaluated by a board certified oncologist.Results: Of the 2000 cases, 18F-FDG PET/CT suggested SM in 146/2000 (7.3%. Of those 146 cases, 105 (72% were positive on both PET and CT. The remaining 41 (28% had PET positive CT negative bone lesions. SM was confirmed in 36/41 (88% PET positive/CT negative cases. This was based on biopsy, imaging or clinical follow-up. The detection of PET positive CT negative SM did not change staging or management in 7/36 (19.4%. However, staging and/or management was affected in 29/36 (80.6%. Conclusions: SM is not uncommon in 18F-FDG PET/CT, as it accounts for 146/2000 (7.3% of cases. PET demonstrated FDG-avid SM without a CT abnormality in at least 36/146 (25%. Patients staging and or management changed in 29/36 (80.5%. We concluded that 18F-FDG PET is sensitive in detection of SM with significant impact on staging & or management. Key words18F-FDG PET/CT, Skeletal metastasis, PET positive, CT negative

  17. Detecting and Attributing Health Burdens to Climate Change.

    Science.gov (United States)

    Ebi, Kristie L; Ogden, Nicholas H; Semenza, Jan C; Woodward, Alistair

    2017-08-07

    Detection and attribution of health impacts caused by climate change uses formal methods to determine a ) whether the occurrence of adverse health outcomes has changed, and b ) the extent to which that change could be attributed to climate change. There have been limited efforts to undertake detection and attribution analyses in health. Our goal was to show a range of approaches for conducting detection and attribution analyses. Case studies for heatwaves, Lyme disease in Canada, and Vibrio emergence in northern Europe highlight evidence that climate change is adversely affecting human health. Changes in rates and geographic distribution of adverse health outcomes were detected, and, in each instance, a proportion of the observed changes could, in our judgment, be attributed to changes in weather patterns associated with climate change. The results of detection and attribution studies can inform evidence-based risk management to reduce current, and plan for future, changes in health risks associated with climate change. Gaining a better understanding of the size, timing, and distribution of the climate change burden of disease and injury requires reliable long-term data sets, more knowledge about the factors that confound and modify the effects of climate on health, and refinement of analytic techniques for detection and attribution. At the same time, significant advances are possible in the absence of complete data and statistical certainty: there is a place for well-informed judgments, based on understanding of underlying processes and matching of patterns of health, climate, and other determinants of human well-being. https://doi.org/10.1289/EHP1509.

  18. Slc7a11 (xCT) protein expression is not altered in the depressed brain and system xc- deficiency does not affect depression-associated behaviour in the corticosterone mouse model.

    Science.gov (United States)

    Demuyser, Thomas; Deneyer, Lauren; Bentea, Eduard; Albertini, Giulia; Femenia, Teresa; Walrave, Laura; Sato, Hideyo; Danbolt, Niels C; De Bundel, Dimitri; Michotte, Alex; Lindskog, Maria; Massie, Ann; Smolders, Ilse

    2017-09-27

    The cystine/glutamate antiporter (system xc-) is believed to contribute to nonvesicular glutamate release from glial cells in various brain areas. Although recent investigations implicate system xc- in mood disorders, unambiguous evidence has not yet been established. Therefore, we evaluated the possible role of system xc- in the depressive state. We conducted a protein expression analysis of the specific subunit of system xc- (xCT) in brain regions of the corticosterone mouse model, Flinders Sensitive Line rat model and post-mortem tissue of depressed patients. We next subjected system xc- deficient mice to the corticosterone model and analysed their behaviour in several tests. Lastly, we subjected additional cohorts of xCT-deficient and wild-type mice to N-acetylcysteine treatment to unveil whether the previously reported antidepressant-like effects are dependent upon system xc-. We did not detect any changes in xCT expression levels in the animal models or patients compared to proper controls. Furthermore, loss of system xc- had no effect on depression- and anxiety-like behaviour. Finally, the antidepressant-like effects of N-acetylcysteine are not mediated via system xc-. xCT protein expression is not altered in the depressed brain and system xc- deficiency does not affect depression-associated behaviour in the corticosterone mouse model.

  19. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  20. Relating auditory attributes of multichannel sound to preference and to physical parameters

    DEFF Research Database (Denmark)

    Choisel, Sylvain; Wickelmaier, Florian Maria

    2006-01-01

    playing a role in sound quality evaluation. Eight selected attributes are quantified by a panel of 39 listeners using paired-comparison judgments and probabilistic choice models, and related to overall preference. A multiple-regression model predicts preference well, and some similarities are observed......Sound reproduced by multichannel systems is affected by many factors giving rise to various sensations, or auditory attributes. Relating specific attributes to overall preference and to physical measures of the sound field provides valuable information for a better understanding of the parameters...

  1. Three cases of acute encephalopathy with low density areas in the occipital lobes on CT

    International Nuclear Information System (INIS)

    Nakajima, Masako; Nakano, Chizuko; Takakura, Hiroki; Otani, Kyoichi.

    1985-01-01

    Three female infants with acute encephalopathy (aged from 5 months to 1 year and 8 months) are presented in whom peculiar features were obtained on cranial CT. Disturbances of consciousness and spasm were seen in all patients. Although two patients had been in good health until the onset, the other patient had had nodular sclerosis. Laboratory data showed no evidence of inflammation in the spinal fluid, but increased levels of transaminase and LDH. CT around 7 days after the onset revealed diffuse low density areas. This was noted in the temporal and occipital lobes, mainly resulting from edema. Follow-up CT examinations revealed localized low density areas corresponding to the surface area, being probably attributable to disturbances of the arterial and venous circulations. In two patients with severe disturbances of consciousness, low density areas became more marked with time. (Namekawa, K.)

  2. Attending to the reasons for attribute non-attendance in choice experiments

    DEFF Research Database (Denmark)

    Alemu, Mohammed Hussen; Mørkbak, Morten Raun; Olsen, Søren Bøye

    2013-01-01

    This paper focuses on behavioural reasons underlying stated attribute non-attendance in choice experiments. In order to identify and incorporate procedures for dealing with heterogeneous attribute processing strategies, we ask respondents follow-up questions regarding their reasons for ignoring...... not affect their utility. Excluding these genuine zero preferences, as the standard approach essentially does, might bias results. Other respondents claim to have ignored attributes to simplify choices. However, we find that these respondents have actually not completely ignored attributes. We argue along...... the rationally adaptive behavioural model that valid preference information may indeed be elicited in these cases, and we illustrate how recoding of non-attendance statements conditional on stated reasons may be a more appropriate solution than the current standard way of taking stated non...

  3. A longitudinal examination of perceived discrimination and depressive symptoms in ethnic minority youth: The roles of attributional style, positive ethnic/racial affect, and emotional reactivity.

    Science.gov (United States)

    Stein, Gabriela L; Supple, Andrew J; Huq, Nadia; Dunbar, Angel S; Prinstein, Mitchell J

    2016-02-01

    Although perceived ethnic/racial discrimination is well established as a risk factor for depressive symptoms in ethnic minority youth, few studies have examined their longitudinal relationship over time. This study examined whether a negative attributional style, positive ethnic/racial affect, and emotional reactivity moderated the longitudinal relationship of perceived peer or adult discrimination and depressive symptoms in a sample of African American and Latino high school students (n = 155). African American and Latino youth who experienced increases in perceived peer discrimination also reported greater depressive symptoms over time, but positive ethnic/racial affect buffered the longitudinal association. Emotional reactivity also served as a significant moderator but only of the baseline association between perceived peer discrimination and depressive symptoms. Thus, perceived ethnic/racial discrimination appears to play a significant role in the development of depressive symptoms for ethnic minority youth, especially those who start high school with lower levels of positive ethnic/racial affect. PsycINFO Database Record (c) 2016 APA, all rights reserved.

  4. Range and number-of-levels effects in derived and stated measures of attribute importance

    NARCIS (Netherlands)

    Verlegh, PWJ; Schifferstein, HNJ; Wittink, DR

    We study how the range of variation and the number of ttribute levels affect five measures of attribute importance: full profile conjoint estimates, ranges in attribute level attractiveness ratings. regression coefficients. graded paired comparisons. and self-reported ratings, We find that all

  5. CT findings of plastic bronchitis in children after a Fontan operation

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea); Jhang, Won Kyoung; Kim, Young Hwee; Ko, Jae Kon; Park, In Sook [University of Ulsan College of Medicine, Department of Pediatric Cardiology, Asan Medical Center, Seoul (Korea); Park, Jeong-Jun; Yun, Tae-Jin; Seo, Dong-Man [University of Ulsan College of Medicine, Department of Pediatric Cardiac Surgery, Asan Medical Center, Seoul (Korea)

    2008-09-15

    Plastic bronchitis is a rare cause of acute obstructive respiratory failure in children. Life-threatening events are much more frequent in patients with repaired cyanotic congenital heart disease, and most frequent following a Fontan operation. Commonly, the diagnosis is not made until bronchial casts are expectorated. Detailed CT findings in plastic bronchitis have not been described. To describe the CT findings in plastic bronchitis in children after a Fontan operation. Three children with plastic bronchitis after a Fontan operation were evaluated by chest CT. Bronchial casts were spontaneously expectorated and/or extracted by bronchoscopy. Airway and lung abnormalities seen on CT were analyzed in the three children. CT demonstrated bronchial casts in the central airways with associated atelectasis and consolidation in all children. The affected airways were completely or partially obstructed by the bronchial casts without associated bronchiectasis. The airway and lung abnormalities rapidly improved after removal of the bronchial casts. CT can identify airway and lung abnormalities in children with plastic bronchitis after a Fontan operation. In addition, CT can be used to guide bronchoscopy and to monitor treatment responses, and thereby may improve clinical outcomes. (orig.)

  6. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  7. CT appearances of abdominal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.-K., E-mail: leewk33@hotmail.com [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Van Tonder, F.; Tartaglia, C.J.; Dagia, C. [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Cazzato, R.L. [Department of Radiology, Universita Campus Bio-Medico di Roma, Rome (Italy); Duddalwar, V.A. [Department of Radiology, Norris Comprehensive Cancer Center, University of Southern California, Los Angeles, California (United States); Chang, S.D. [Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, British Columbia (Canada)

    2012-06-15

    The purpose of this article is to review and illustrate the spectrum of computed tomography (CT) appearances of abdominal tuberculosis. Tuberculosis can affect any organ or tissue in the abdomen, and can be mistaken for other inflammatory or neoplastic conditions. The most common sites of tuberculosis in the abdomen include lymph nodes, genitourinary tract, peritoneal cavity and gastrointestinal tract. The liver, spleen, biliary tract, pancreas and adrenals are rarely affected, but are more likely in HIV-seropositive patients and in miliary tuberculosis. This article should alert the radiologist to consider abdominal tuberculosis in the correct clinical setting to ensure timely diagnosis and enable appropriate treatment.

  8. CT appearances of abdominal tuberculosis

    International Nuclear Information System (INIS)

    Lee, W.-K.; Van Tonder, F.; Tartaglia, C.J.; Dagia, C.; Cazzato, R.L.; Duddalwar, V.A.; Chang, S.D.

    2012-01-01

    The purpose of this article is to review and illustrate the spectrum of computed tomography (CT) appearances of abdominal tuberculosis. Tuberculosis can affect any organ or tissue in the abdomen, and can be mistaken for other inflammatory or neoplastic conditions. The most common sites of tuberculosis in the abdomen include lymph nodes, genitourinary tract, peritoneal cavity and gastrointestinal tract. The liver, spleen, biliary tract, pancreas and adrenals are rarely affected, but are more likely in HIV-seropositive patients and in miliary tuberculosis. This article should alert the radiologist to consider abdominal tuberculosis in the correct clinical setting to ensure timely diagnosis and enable appropriate treatment.

  9. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  10. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  11. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  12. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  13. Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across europe

    International Nuclear Information System (INIS)

    Zarb, F.; McEntee, M.; Rainford, L.

    2012-01-01

    This work recommends dose reference levels (DRLs) for abdomen, chest and head computerised tomography (CT) examinations in Malta as the first step towards national CT dose optimisation. Third quartiles volume CT dose index values for abdomen: 12.1 mGy, chest: 13.1 mGy and head: 41 mGy and third quartile dose-length product values for abdomen: 539.4, chest: 492 and head: 736 mGy cm -1 are recommended as Maltese DRLs derived from this first Maltese CT dose survey. These values compare well with DRLs of other European countries indicating that CT scanning in Malta is consistent with standards of good practice. Further work to minimise dose without affecting image quality and extending the establishment of DRLs for other CT examinations is recommended. (authors)

  14. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  15. Causal attributions of cleft lip and palate across cultures.

    Science.gov (United States)

    Mednick, Lauren; Snyder, Julie; Schook, Carolyn; Blood, Emily A; Brown, Shan-Estelle; Weatherley-White, R C A

    2013-11-01

    Objective : To describe and compare the causal beliefs associated with cleft lips and/or palates across several different countries. Design : Cross-sectional survey. Setting : Operation Smile surgery screenings in six developing countries. Participants : Two hundred seventy-nine adult patients and parents of children with cleft lips and/or palates in Kenya, Russia, Cambodia, India, Egypt, and Peru. Interventions : In person interviews were conducted with interpreters. Main Outcome Measure : As part of a larger study, a semistructured questionnaire was created to explore cleft perceptions, belief systems that affect these perceptions, and social reactions to individuals with clefts. Results : Causal attributions were grouped by category (environment, self-blame, supernatural, chance, unknown, or other) and type of locus of control (external, internal, or unknown). Results indicate significant difference by country for both causal attribution category (P < .001) and type (P < .001). This difference was maintained in multivariate analyses, which controlled for differences by demographic variables between countries. Conclusions : This study provides evidence that causal attributions for clefts are influenced by culture. As harmful beliefs about cause may continue to impact affected individuals and their families even after a repair, it is insufficient to provide surgical care alone. Care of the entire person must include attempts to change misinformed cultural beliefs through educating the broader community.

  16. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  17. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  18. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon

    1988-01-01

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult cases.

  19. Reliability and error analysis on xenon/CT CBF

    International Nuclear Information System (INIS)

    Zhang, Z.

    2000-01-01

    This article provides a quantitative error analysis of a simulation model of xenon/CT CBF in order to investigate the behavior and effect of different types of errors such as CT noise, motion artifacts, lower percentage of xenon supply, lower tissue enhancements, etc. A mathematical model is built to simulate these errors. By adjusting the initial parameters of the simulation model, we can scale the Gaussian noise, control the percentage of xenon supply, and change the tissue enhancement with different kVp settings. The motion artifact will be treated separately by geometrically shifting the sequential CT images. The input function is chosen from an end-tidal xenon curve of a practical study. Four kinds of cerebral blood flow, 10, 20, 50, and 80 cc/100 g/min, are examined under different error environments and the corresponding CT images are generated following the currently popular timing protocol. The simulated studies will be fed to a regular xenon/CT CBF system for calculation and evaluation. A quantitative comparison is given to reveal the behavior and effect of individual error resources. Mixed error testing is also provided to inspect the combination effect of errors. The experiment shows that CT noise is still a major error resource. The motion artifact affects the CBF results more geometrically than quantitatively. Lower xenon supply has a lesser effect on the results, but will reduce the signal/noise ratio. The lower xenon enhancement will lower the flow values in all areas of brain. (author)

  20. The value of early CT in complicated childhood pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Tan Kendrick, A.P. [Department of Diagnostic Imaging, Kandang Kerbau Women' s and Children' s Hospital (Singapore); Ling, Ho [Department of Paediatric Medicine, Kandang Kerbau Women' s and Children' s Hospital (Singapore); Subramaniam, Ramnath; Joseph, Vijeyakaran T. [Department of Paediatric Surgery, Kandang Kerbau Women' s and Children' s Hospital (Singapore)

    2002-01-01

    Objective. To investigate the value of CT in complicated childhood pneumonia and its role in early intervention when chest radiography (CXR) is non-contributory. Materials and methods. Forty-two immunocompetent children, aged 1-11 years, admitted for community-acquired pneumonia from October 1997 to September 1999, had 42 contrast-enhanced CT scans and frontal chest radiographs on the same day, which were assessed independently. CT was performed when the patient remained unwell and the CXR images showed failure of resolution despite 7-10 days of antibiotics and/or drainage with urokinase therapy. Results. Compared to CT, CXR revealed suboptimal accuracy rates of lobar involvement (84%), chest tube placement (73%), fluid loculation (42%), abscess formation (40%) and bronchopleural fistulae (33%). It could not assess parenchymal or pleural complications such as cavitary necrosis, early abscess formation, empyemas or pericardial effusions. On the basis of the CT findings and poor clinical progress, 16 patients underwent surgical intervention with the aid of video-assisted thorascopic surgery (VATS). The CT features correlated well with surgical findings. Ten cases required pleural decortication while six with destructive or necrotic lung lesions had surgical resection. Debridement was difficult when the pleura had become thick and fibrotic. Streptococcus pneumoniae was the offending organism in 81% of cases. The right side was affected in 67% of cases. Conclusions. In complicated childhood pneumonia, CT is far superior to CXR in revealing pleural and parenchymal complications, which may require early surgical intervention. (orig.)

  1. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  2. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  3. Evaluating the Locational Attributes of Education Management Organizations (EMOs)

    Science.gov (United States)

    Gulosino, Charisse; Miron, Gary

    2017-01-01

    This study uses logistic and multinomial logistic regression models to analyze neighborhood factors affecting EMO (Education Management Organization)-operated schools' locational attributes (using census tracts) in 41 states for the 2014-2015 school year. Our research combines market-based school reform, institutional theory, and resource…

  4. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  5. Optimization of pediatric examinations in a multislice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Ombada, T H. A. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI{sub v}ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI{sub v}ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  6. Analysis of discrepancy between neurologic findings and CT findings in 60 patients with herniated nucleus pulposus

    International Nuclear Information System (INIS)

    Lee, Hyun; Kim, Kab Tae; Sol, Chang Hyo; Kim, Byung Soo

    1987-01-01

    The herniated nucleus pulposus (HNP) is a major cause of low back pain and sciatica. High resolution computed tomography is the most accurate diagnostic tool to define a HNP, because it provides a complete in vivo analysis of bony framework of lumbar spine as well as the supporting soft tissue structures and neural elements. But the discrepancy between neurologic findings and CT findings is often confusing. From May 1983 to August 1986, sixty patients with HNP who had both CT and surgical intervention at Pusan National University Hospital were analyzed. The feasibility of the neurologic examination on HNP and the effect of HNP on nerve root were evaluated on the basis of CT findings. The results were as follows : 1. Thirty-four cases (56.7%) of clinical impression were matched to CT findings in determining level of HNP and affected nerve root. 2. In evaluation of affected level, there was high trend to cause discrepancy between neurologic findings and CT findings in multiple disc involvement than in single involvement. 3. There was no correlation between degree of nerve root compression determined by CT and pattern of neurologic signs (motor weakness, sensory deficit, and reflex change)

  7. Analysis of discrepancy between neurologic findings and CT findings in 60 patients with herniated nucleus pulposus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun; Kim, Kab Tae; Sol, Chang Hyo; Kim, Byung Soo [College of Medicine, Pusan National University, Busan(Korea, Republic of)

    1987-06-15

    The herniated nucleus pulposus (HNP) is a major cause of low back pain and sciatica. High resolution computed tomography is the most accurate diagnostic tool to define a HNP, because it provides a complete in vivo analysis of bony framework of lumbar spine as well as the supporting soft tissue structures and neural elements. But the discrepancy between neurologic findings and CT findings is often confusing. From May 1983 to August 1986, sixty patients with HNP who had both CT and surgical intervention at Pusan National University Hospital were analyzed. The feasibility of the neurologic examination on HNP and the effect of HNP on nerve root were evaluated on the basis of CT findings. The results were as follows : 1. Thirty-four cases (56.7%) of clinical impression were matched to CT findings in determining level of HNP and affected nerve root. 2. In evaluation of affected level, there was high trend to cause discrepancy between neurologic findings and CT findings in multiple disc involvement than in single involvement. 3. There was no correlation between degree of nerve root compression determined by CT and pattern of neurologic signs (motor weakness, sensory deficit, and reflex change)

  8. How does the chemistry of polymer gel dosimeters affect their performance?

    International Nuclear Information System (INIS)

    Jirasek, A; McAuley, K B; Lepage, M

    2009-01-01

    This review article describes the primary chemical processes affecting polymerization in polymer-based radiosensitive gel dosimeters. Furthermore, recently studied environmental factors and gelation processes affecting polymerization and gel dose response are discussed. Finally, the predominant physical factors affecting dose-response sensitivity for each of the three imaging modalities (MRI, Optical CT, x-ray CT) are outlined. Emphasis is concentrated on recent literature in this area, as prior literature was summarized in review articles submitted to DOSGEL 2006 in Sherbrooke (J. Conf. Series, 56, 2006). Discussions from the recent DOSGEL conference (2008) are incorporated into this review.

  9. How does the chemistry of polymer gel dosimeters affect their performance?

    Energy Technology Data Exchange (ETDEWEB)

    Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria BC V8W 3P6 (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston ON K7L 3N6 (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Universite de Sherbrooke, 3001 12e Avenue Nord, Sherbrooke QC J1H 5N4 (Canada)], E-mail: jirasek@uvic.ca, E-mail: kim.mcauley@chee.queensu.ca, E-mail: martin.lepage@usherbrooke.ca

    2009-05-01

    This review article describes the primary chemical processes affecting polymerization in polymer-based radiosensitive gel dosimeters. Furthermore, recently studied environmental factors and gelation processes affecting polymerization and gel dose response are discussed. Finally, the predominant physical factors affecting dose-response sensitivity for each of the three imaging modalities (MRI, Optical CT, x-ray CT) are outlined. Emphasis is concentrated on recent literature in this area, as prior literature was summarized in review articles submitted to DOSGEL 2006 in Sherbrooke (J. Conf. Series, 56, 2006). Discussions from the recent DOSGEL conference (2008) are incorporated into this review.

  10. PET-CT in oncological patients: analysis of informal care costs in cost-benefit assessment.

    Science.gov (United States)

    Orlacchio, Antonio; Ciarrapico, Anna Micaela; Schillaci, Orazio; Chegai, Fabrizio; Tosti, Daniela; D'Alba, Fabrizio; Guazzaroni, Manlio; Simonetti, Giovanni

    2014-04-01

    The authors analysed the impact of nonmedical costs (travel, loss of productivity) in an economic analysis of PET-CT (positron-emission tomography-computed tomography) performed with standard contrast-enhanced CT protocols (CECT). From October to November 2009, a total of 100 patients referred to our institute were administered a questionnaire to evaluate the nonmedical costs of PET-CT. In addition, the medical costs (equipment maintenance and depreciation, consumables and staff) related to PET-CT performed with CECT and PET-CT with low-dose nonenhanced CT and separate CECT were also estimated. The medical costs were 919.3 euro for PET-CT with separate CECT, and 801.3 euro for PET-CT with CECT. Therefore, savings of approximately 13% are possible. Moreover, savings in nonmedical costs can be achieved by reducing the number of hospital visits required by patients undergoing diagnostic imaging. Nonmedical costs heavily affect patients' finances as well as having an indirect impact on national health expenditure. Our results show that PET-CT performed with standard dose CECT in a single session provides benefits in terms of both medical and nonmedical costs.

  11. PET-CT findings in patients with polymyalgia rheumatica without symptoms of cranial ischaemia

    DEFF Research Database (Denmark)

    Lund-Petersen, Alexander; Voss, Anne; Laustrup, Helle

    2017-01-01

    Introduction: Polymyalgia rheumatica (PMR) is an inflammatory disorder that affects the lderly. At present, evidence is limited regarding the usefulness of positron emission tomography-computed tomography (PET-CT) in the diagnosis of PMR. This study aimed to compare patient characteristics...... and symptoms with PET-CT findings in a Danish population of PMR patients without clinical symptoms of giant cell arteritis. Methods: The medical records of 50 Danish PET-CT-scanned patients with PMR were reviewed. Symptoms, characteristics and PET-CT findings were registered from the medical records. Results...... of the following three locations: the shoulder, the hip and the spinous processes. Vascular FDG uptake was seen in 7% of the patients. No significant correlations between any symptoms and any PET-CT findings were found. C-reactive protein was significantly lower in patients receiving glucocorticoids...

  12. First installation of a dual-room IVR-CT system in the emergency room.

    Science.gov (United States)

    Wada, Daiki; Nakamori, Yasushi; Kanayama, Shuji; Maruyama, Shuhei; Kawada, Masahiro; Iwamura, Hiromu; Hayakawa, Koichi; Saito, Fukuki; Kuwagata, Yasuyuki

    2018-03-05

    Computed tomography (CT) embedded in the emergency room has gained importance in the early diagnostic phase of trauma care. In 2011, we implemented a new trauma workflow concept with a sliding CT scanner system with interventional radiology features (IVR-CT) that allows CT examination and emergency therapeutic intervention without relocating the patient, which we call the Hybrid emergency room (Hybrid ER). In the Hybrid ER, all life-saving procedures, CT examination, damage control surgery, and transcatheter arterial embolisation can be performed on the same table. Although the trauma workflow realized in the Hybrid ER may improve mortality in severe trauma, the Hybrid ER can potentially affect the efficacy of other in/outpatient diagnostic workflow because one room is occupied by one severely injured patient undergoing both emergency trauma care and CT scanning for long periods. In July 2017, we implemented a new trauma workflow concept with a dual-room sliding CT scanner system with interventional radiology features (dual-room IVR-CT) to increase patient throughput. When we perform emergency surgery or interventional radiology for a severely injured or ill patient in the Hybrid ER, the sliding CT scanner moves to the adjacent CT suite, and we can perform CT scanning of another in/outpatient. We believe that dual-room IVR-CT can contribute to the improvement of both the survival of severely injured or ill patients and patient throughput.

  13. GPA and Attribute Framing Effects: Are Better Students More Sensitive or More Susceptible?

    Science.gov (United States)

    Dunegan, Ken

    2010-01-01

    Data from 2 studies show students differ in terms of how attribute framing alters perceptions and reactions in a decision-making episode. Using student GPA as a moderator, results from a role-play-decision-making exercise (Experiment 1) show perceptions and intended actions of higher GPA students were more strongly affected by attribute framing…

  14. Effect of tensile properties on time-dependent C(t) and J(t) integrals in elastic-plastic-creep FE analysis

    International Nuclear Information System (INIS)

    Lee, So-Dam; Lee, Han-Sang; Kim, Yun-Jae; Ainsworth, Robert A.; Dean, David W.

    2016-01-01

    This technical note presents the effect of elastic-plastic properties on calculated time-dependent C(t) and J(t) values. This is investigated via systematic elastic-plastic-creep finite element (FE) analysis. Three different stress-strain curves are used, having essentially the same plastic properties at large strains but different tensile data near the 0.2% proof (yield) strength. It is found that the plastic property in stress-strain curve affects the FE C(t) values only at short times (within approximately 20% of the redistribution time). The plastic property affects the initial J values at time t = 0 but not the rate of change of J(t) with time. - Highlights: • The effect of elastic-plastic properties on calculated time-dependent C(t) and J(t) values is presented via FE analysis. • The plastic property affects the FE C(t) values only at short times up to ∼20% of the redistribution time. • The plastic property affects the initial J values at time t = 0 but not the rate of change of J(t) with time.

  15. Effects of acute tryptophan depletion on central processing of CT-targeted and discriminatory touch in humans.

    Science.gov (United States)

    Trotter, Paula Diane; McGlone, Francis; McKie, Shane; McFarquhar, Martyn; Elliott, Rebecca; Walker, Susannah Claire; Deakin, John Francis William

    2016-08-01

    C-tactile afferents (CTs) are slowly conducting nerve fibres, present only in hairy skin. They are optimally activated by slow, gentle stroking touch, such as those experienced during a caress. CT stimulation activates affective processing brain regions, alluding to their role in affective touch perception. We tested a theory that CT-activating touch engages the pro-social functions of serotonin, by determining whether reducing serotonin, through acute tryptophan depletion, diminishes subjective pleasantness and affective brain responses to gentle touch. A tryptophan depleting amino acid drink was administered to 16 healthy females, with a further 14 receiving a control drink. After 4 h, participants underwent an fMRI scan, during which time CT-innervated forearm skin and CT non-innervated finger skin was stroked with three brushes of differing texture, at CT-optimal force and velocity. Pleasantness ratings were obtained post scanning. The control group showed a greater response in ipsilateral orbitofrontal cortex to CT-activating forearm touch compared to touch to the finger where CTs are absent. This differential response was not present in the tryptophan depleted group. This interaction effect was significant. In addition, control participants showed a differential primary somatosensory cortex response to brush texture applied to the finger, a purely discriminatory touch response, which was not observed in the tryptophan depleted group. This interaction effect was also significant. Pleasantness ratings were similar across treatment groups. These results implicate serotonin in the differentiation between CT-activating and purely discriminatory touch responses. Such effects could contribute to some of the social abnormalities seen in psychiatric disorders associated with abnormal serotonin function. © 2016 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  16. Perceptual attributes for the comparison of head-related transfer functions.

    Science.gov (United States)

    Simon, Laurent S R; Zacharov, Nick; Katz, Brian F G

    2016-11-01

    The benefit of using individual head-related transfer functions (HRTFs) in binaural audio is well documented with regards to improving localization precision. However, with the increased use of binaural audio in more complex scene renderings, cognitive studies, and virtual and augmented reality simulations, the perceptual impact of HRTF selection may go beyond simple localization. In this study, the authors develop a list of attributes which qualify the perceived differences between HRTFs, providing a qualitative understanding of the perceptual variance of non-individual binaural renderings. The list of attributes was designed using a Consensus Vocabulary Protocol elicitation method. Participants followed an Individual Vocabulary Protocol elicitation procedure, describing the perceived differences between binaural stimuli based on binauralized extracts of multichannel productions. This was followed by an automated lexical reduction and a series of consensus group meetings during which participants agreed on a list of relevant attributes. Finally, the proposed list of attributes was then evaluated through a listening test, leading to eight valid perceptual attributes for describing the perceptual dimensions affected by HRTF set variations.

  17. Helical CT for lung-cancer screening. 3. Fundamental study for ultra-low-dose CT by application of small tube current and filter

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Koyama, Shuji; Tusaka, Masatoshi; Maekoshi, Hisashi; Satake, Hiroko; Ishigaki, Takeo.

    1996-01-01

    In order to develop ultra-low-dose helical CT for lung cancer screening, the effect of reduction of the tube current to 20 mA and application of a 10 mm thick aluminium filter upon radiation dose and image quality was evaluated with a phantom. Exposure dose at the center of a gantry and absorbed dose at the center of an acrylic phantom at 20 mA with the filter were 15% and 29% of the dose at 50 mA without the filter, respectively. For reduction of absorbed dose, reduction of the tube current was more useful than application of the filter. Image noise at 20 mA with the filter was double that at 50 mA without the filter. Neither reduction of the tube current nor application of the filter changed full width at half maximum on section sensitivity of the Z-axis. Although reduction of the tube current did not affect the difference in CT values between an acrylic sphere and styroform, application of the filter caused a reduction of 4.5% in the difference in CT values. Neither reduction of the tube current nor application of the filter affected the contrast resolution of the high-contrast phantom; however, that of the low-contrast phantom deteriorated. Although improvement of the filter and evaluation of clinical images are necessary, reduction of the tube current to 20 mA and application of the aluminium filter appear to be a promising method for ultra-low-dose helical CT of the lung. (author)

  18. Improving the Accuracy of Attribute Extraction using the Relatedness between Attribute Values

    Science.gov (United States)

    Bollegala, Danushka; Tani, Naoki; Ishizuka, Mitsuru

    Extracting attribute-values related to entities from web texts is an important step in numerous web related tasks such as information retrieval, information extraction, and entity disambiguation (namesake disambiguation). For example, for a search query that contains a personal name, we can not only return documents that contain that personal name, but if we have attribute-values such as the organization for which that person works, we can also suggest documents that contain information related to that organization, thereby improving the user's search experience. Despite numerous potential applications of attribute extraction, it remains a challenging task due to the inherent noise in web data -- often a single web page contains multiple entities and attributes. We propose a graph-based approach to select the correct attribute-values from a set of candidate attribute-values extracted for a particular entity. First, we build an undirected weighted graph in which, attribute-values are represented by nodes, and the edge that connects two nodes in the graph represents the degree of relatedness between the corresponding attribute-values. Next, we find the maximum spanning tree of this graph that connects exactly one attribute-value for each attribute-type. The proposed method outperforms previously proposed attribute extraction methods on a dataset that contains 5000 web pages.

  19. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  20. Progress in biosimilar monoclonal antibody development: the infliximab biosimilar CT-P13 in the treatment of rheumatic diseases.

    Science.gov (United States)

    Braun, Jürgen; Kudrin, Alex

    2015-01-01

    Biosimilars are biologic medical products whose active drug substance is made by a living organism or derived from it. The term is used to describe a subsequent version of an innovator biopharmaceutical product aiming at approval following patent expiry on the reference product. Biosimilars of monoclonal need to demonstrate similar but not identical quality of nonclinical and clinical attributes. Not all data of the originator product need to be recapitulated, as large numbers of patient-years of exposure data are already available. Thus, biosimilar development is largely based on the safety profiles of the originator product. The evaluation of biosimilarity includes immunogenicity attributed risks. CT-P13 (Remsima™/Inflectra™, Celltrion/Hospira), a biosimilar of the innovator drug infliximab (INF), was the first approved complex biosimilar monoclonal antibody in the EU, within the framework of WHO, EMA and US FDA biosimilar guidelines. CT-P13 has shown analytical and nonclinical features highly similar to INF including pharmacokinetics, efficacy, safety and immunogenicity profiles in ankylosing spondylitis and rheumatoid arthritis. The objective of this article is to highlight the recent biosimilar development and to review the results from the studies PLANETRA and PLANETAS, which have supported the approval of CT-P13 for several indications.

  1. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  2. Lipeo-sCT: a novel reversible lipidized salmon calcitonin derivative, its biophysical properties and hypocalcemic activity.

    Science.gov (United States)

    Cheng, Weiqiang; Lim, Lee-Yong

    2009-05-12

    We have previously described the design and synthesis of Mal-sCT and compared its biological activity with its reversible counterpart, REAL-sCT. Mal-sCT was salmon calcitonin (sCT) conjugated with two molecules of an epsilon-maleimido lysine derivative of palmitic acid via non-reversible thioether bonds at its cysteine residues while REAL-sCT was sCT conjugated with two molecules of a cysteine derivative of palmitic acid via reducible disulfide bonds at its cysteine residues. Neither compounds when dissolved in water could reproducibly improved the oral deliverability of sCT. The purpose of this study was to characterize and evaluate Lipeo-sCT, a novel sCT analog conjugated via reducible disulfide bonds with two amphiphilic groups consisting of a hydrophobic hexadecyl moiety attached via an ether bond to a hydrophilic triethylene glycol moiety. Lipeo-sCT was successfully synthesized by a 4-step reaction, purified and identified by ESI-MS. Analysis by dynamic light scattering (DLS) and transmission electron microscopy (TEM) suggested it had a propensity to form aggregates in water, although the aggregation behavior was controllable by modulating solvent polarity. MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay indicated a lack of cytotoxicity against the Caco-2 cells at up to 100 microM. Compared with sCT, Lipeo-sCT lowered plasma calcium to comparable levels when injected subcutaneously at 0.15 mg/kg into female Wistar rats, but the hypocalcemic activity of Lipeo-sCT was prolonged by at least 6 more hours. This was attributable to a continual regeneration of sCT from Lipeo-sCT. sCT was detectable in plasma 8h following subcutaneous injection of Lipeo-sCT (1.90 mg/kg), while Lipeo-sCT was not observed in plasma at all time points. By comparison, sCT was detectable in plasma for less than 2.5h following subcutaneous injection at an equivalent dose (1.50mg/kg). Data from this study complement those of previous studies, and add to the body of

  3. The effect of institutional setting on attributional content in management commentary reports

    OpenAIRE

    AERTS, Walter; TARCA, Ann

    2008-01-01

    We study the effect of expected regulatory and litigation costs embedded in a country’s institutional environment on the explanatory content of management commentary reports. Using a behavioural accountability lens, we argue that regulatory control and expected litigation risk affect the attributional framing of financial performance. We also investigate whether differential attributional properties have economic relevance by considering the relationship between content profiles and analyst f...

  4. Case report: Isolated unilateral pulmonary vein atresia diagnosed on 128-slice multidetector CT

    Directory of Open Access Journals (Sweden)

    Rashmi Dixit

    2011-01-01

    Full Text Available Unilateral pulmonary venous atresia is an uncommon entity that is generally believed to be congenital. Most patients present in infancy or childhood with recurrent chest infections or hemoptysis. Pulmonary angiography is usually used for definitive diagnosis. However, the current multislice CT scanners may obviate the need for pulmonary angiography. We report two cases diagnosed using 128-slice CT angiography. On the CT angiography images both these cases demonstrated absent pulmonary veins on the affected side, with a small pulmonary artery and prominent bronchial or other systemic arterial supply.

  5. Causal Attributions of Success and Failure and Mood States in Football Players

    Directory of Open Access Journals (Sweden)

    Szczepaniak Joanna

    2016-12-01

    Full Text Available Introduction. The aim of the study was to determine the causal attributions of success and failure in a football match in a group of football players, as well as to investigate the association of the players’ attributions with their level of achievement and the relationships between their causal attributions and affective states. Material and methods. The study involved 75 football players, including 44 players from the first league and 31 players from the third league. The research was carried out using the Profile of Mood States (POMS by D.M. McNair, M. Lorr, and L.F. Droppleman and a specially designed questionnaire concerning the causal attributions of success and failure. Results. It was found that the football players who participated in the study tended to attribute success to internal causes and failure to external causes. More frequent use of external attributions most likely had an adverse impact on the mood state of the players. Conclusion. Information concerning the attributions that a given player makes can be useful for coaches, as it can help them develop the athlete’s mental abilities more effectively. Beliefs related to attributions can be modified. It is worth considering the benefits of encouraging internal attributions in the case of success and external attributions in situations of failure.

  6. FDG PET/CT is useful for the interim evaluation of response to therapy in patients affected by haematogenous spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina; Ambrosini, Valentina; Fanti, Stefano [Azienda Ospedaliero - Universitaria di Bologna Policlinico S.Orsola Malpighi, Unit of Nuclear Medicine, Bologna (Italy); Boriani, Luca; Gasbarrini, Alessandro; Boriani, Stefano [Rizzoli Orthopaedic Institute, Oncologic and Degenerative Spine Surgery, Bologna (Italy); Salvadori, Caterina; Zamparini, Eleonora; Rorato, Giada; Tumietto, Fabio; Cristini, Francesco; Viale, Pierluigi [Azienda Ospedaliero - Universitaria di Bologna Policlinico S.Orsola Malpighi, Infectious Diseases Unit, Bologna (Italy); Scudeller, Luigia [Policlinico San Matteo Pavia Fondazione IRCCS, Pavia (Italy)

    2012-10-15

    Antibiotic therapy in patients affected by discitis is often empirical. Therefore, early evaluation of response to therapy is important. In many patients inflammatory indexes are low during all the phases of the diseases or are altered by concomitant diseases. The aim of the study was to assess the possible role of FDG PET/CT for the early evaluation of response to therapy in patients affected by infective discitis, in comparison to C-reactive protein (CRP) serum levels. Enrolled in the study were 38 patients diagnosed with haematogenous infective discitis. Of the 38 patients, 7 had tubercular infection, 1 fungal infection and 30 pyogenic discitis. Four patients were excluded because the second PET/CT scan was not performed. Thus 34 patients (18 women, mean age 64 years) were analysed. All the patients included underwent a FDG PET/CT scan and determination of CRP level at baseline and again 2 to 4 weeks after the start of therapy. The PET results in terms of SUV of the first and second scans (SUV1 and SUV2) and delta-SUVmax were compared to the inflammatory indexes and clinical status during therapy. The mean SUVmax at diagnosis was 8.6 {+-} 3.7. The mean CRP level at diagnosis was 3.8 {+-} 3.8 mg/dl. A progressive clinical response was seen in 26 patients and 8 patients showed no response. SUV1 was not correlated with the baseline CRP level (CRP1, p = 0.7) and SUV2 was not correlated with the CRP level at the time of the second scan (CRP2, p = 0.4). In responders, SUV2 and CRP2 were significantly lower than SUV1 and CRP1 (p < 0.0001 and p = 0.001, respectively). ROC curves for delta-SUVmax showed a sensitivity of 82 % and a specificity of 82 % with a cut-off of 34 %. ROC curves for SUV2 showed a sensitivity of 83 % and a specificity of 46 % with a cut-off of 6.4. ROC curves for delta-CRP showed a sensitivity of 67 % and a specificity of 89 % with a cut-off of 74 %. ROC curves for CRP2 showed a sensitivity of 65 % and a specificity of 70 % with a cut-off of 0.7 mg

  7. FDG PET/CT is useful for the interim evaluation of response to therapy in patients affected by haematogenous spondylodiscitis

    International Nuclear Information System (INIS)

    Nanni, Cristina; Ambrosini, Valentina; Fanti, Stefano; Boriani, Luca; Gasbarrini, Alessandro; Boriani, Stefano; Salvadori, Caterina; Zamparini, Eleonora; Rorato, Giada; Tumietto, Fabio; Cristini, Francesco; Viale, Pierluigi; Scudeller, Luigia

    2012-01-01

    Antibiotic therapy in patients affected by discitis is often empirical. Therefore, early evaluation of response to therapy is important. In many patients inflammatory indexes are low during all the phases of the diseases or are altered by concomitant diseases. The aim of the study was to assess the possible role of FDG PET/CT for the early evaluation of response to therapy in patients affected by infective discitis, in comparison to C-reactive protein (CRP) serum levels. Enrolled in the study were 38 patients diagnosed with haematogenous infective discitis. Of the 38 patients, 7 had tubercular infection, 1 fungal infection and 30 pyogenic discitis. Four patients were excluded because the second PET/CT scan was not performed. Thus 34 patients (18 women, mean age 64 years) were analysed. All the patients included underwent a FDG PET/CT scan and determination of CRP level at baseline and again 2 to 4 weeks after the start of therapy. The PET results in terms of SUV of the first and second scans (SUV1 and SUV2) and delta-SUVmax were compared to the inflammatory indexes and clinical status during therapy. The mean SUVmax at diagnosis was 8.6 ± 3.7. The mean CRP level at diagnosis was 3.8 ± 3.8 mg/dl. A progressive clinical response was seen in 26 patients and 8 patients showed no response. SUV1 was not correlated with the baseline CRP level (CRP1, p = 0.7) and SUV2 was not correlated with the CRP level at the time of the second scan (CRP2, p = 0.4). In responders, SUV2 and CRP2 were significantly lower than SUV1 and CRP1 (p < 0.0001 and p = 0.001, respectively). ROC curves for delta-SUVmax showed a sensitivity of 82 % and a specificity of 82 % with a cut-off of 34 %. ROC curves for SUV2 showed a sensitivity of 83 % and a specificity of 46 % with a cut-off of 6.4. ROC curves for delta-CRP showed a sensitivity of 67 % and a specificity of 89 % with a cut-off of 74 %. ROC curves for CRP2 showed a sensitivity of 65 % and a specificity of 70 % with a cut-off of 0.7 mg

  8. CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT

    International Nuclear Information System (INIS)

    Christe, Andreas; Lin, Margaret C.; Yen, Andrew C.; Hallett, Rich L.; Roychoudhury, Kingshuk; Schmitzberger, Florian; Fleischmann, Dominik; Leung, Ann N.; Rubin, Geoffry D.; Vock, Peter; Roos, Justus E.

    2012-01-01

    Purpose: To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients. Materials and methods: Raw data of thoracic CT scans (64 × 0.75 mm, 120 kVp, 300 reference mAs) from 41 consecutive patients with clinical suspicion of pulmonary fungal infection were collected. In 32 patients fungal infection could be proven (median age of 55.5 years, range 35–83). A total of 267 cuboids showing CT patterns of fungal infection and 27 cubes having no disease were reconstructed at the original and 6 simulated tube currents of 100, 40, 30, 20, 10, and 5 reference mAs. Eight specific fungal CT patterns were analyzed by three radiologists: 76 ground glass opacities, 42 ground glass nodules, 51 mixed, part solid, part ground glass nodules, 36 solid nodules, 5 lobulated nodules, 6 spiculated nodules, 14 cavitary nodules, and 37 foci of air-space disease. The standard of reference was a consensus subjective interpretation by experts whom were not readers in the study. Results: The mean sensitivity and standard deviation for detecting pathological cuboids/disease using standard dose CT was 0.91 ± 0.07. Decreasing dose did not affect sensitivity significantly until the lowest dose level of 5 mAs (0.87 ± 0.10, p = 0.012). Nodular pattern discrimination was impaired below the dose level of 30 reference mAs: specificity for fungal ‘mixed nodules’ decreased significantly at 20, 10 and 5 reference mAs (p < 0.05). At lower dose levels, classification drifted from ‘solid’ to ‘mixed nodule’, although no lesion was missed. Conclusion: Our simulation data suggest that tube current levels can be reduced from 300 to 30 reference mAs without impairing the diagnostic information of specific CT patterns of pulmonary fungal infections

  9. Comparison of CT and diffusion-weighted MRI in acute ischemic stroke

    International Nuclear Information System (INIS)

    Moriwaki, Hiroshi; Okazaki, Shuhei; Yamada, Naoaki; Naritomi, Hiroaki

    2006-01-01

    Non-contrast CT and diffusion-weighted MRI (DWI) are widely used for assessing patients with acute ischemic stroke including candidates for thrombolytic therapy. Early CT signs, still a gold standard as the diagnostic measure for thrombolysis, are quite subtle and strongly depend on image quality. We evaluated 76 patients (47 male, mean age 71.0 yrs) with ischemic stroke of the anterior cerebral circulation who underwent CT and DWI within 6 hours of onset. The scans were examined separately by two neurologists in a blinded fashion with knowledge of the affected hemisphere. Detection of acute ischemic changes were significantly higher on DWI (72/76, 95%) compared with that on CT (50/76, 66%) (P<0.0001), especially in cases with subcortical lesions (P<0.001). Detection of the lesion with more than 33% of MCA involvement, which should exclude from the thrombolitic therapy, was somewhat higher for DWI (26/26, 100%) compared with CT (22/26, 85%). DWI is more sensitive than CT in the identification of acute ischemic stroke and can visualize major ischemia more easily than CT. Additional studies are required to determine whether these advantages of DWI are clinically relevant in the management of patients with acute stroke. (author)

  10. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  11. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  12. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  13. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  14. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  15. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  16. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  17. Exercise identity and attribution properties predict negative self-conscious emotions for exercise relapse.

    Science.gov (United States)

    Flora, Parminder K; Strachan, Shaelyn M; Brawley, Lawrence R; Spink, Kevin S

    2012-10-01

    Research on exercise identity (EXID) indicates that it is related to negative affect when exercisers are inconsistent or relapse. Although identity theory suggests that causal attributions about this inconsistency elicit negative self-conscious emotions of shame and guilt, no EXID studies have examined this for exercise relapse. Weiner's attribution-based theory of interpersonal motivation (2010) offers a means of testing the attribution-emotion link. Using both frameworks, we examined whether EXID and attributional properties predicted negative emotions for exercise relapse. Participants (n = 224) read an exercise relapse vignette, and then completed EXID, attributions, and emotion measures. Hierarchical multiple regression models using EXID and the attributional property of controllability significantly predicted each of shame and guilt, R² adjusted = .09, ps ≤ .001. Results support identity theory suggestions and Weiner's specific attribution-emotion hypothesis. This first demonstration of an interlinking of EXID, controllability, and negative self-conscious emotions offers more predictive utility using complementary theories than either theory alone.

  18. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  19. Image quality of cone beam CT on respiratory motion

    International Nuclear Information System (INIS)

    Zhang Ke; Li Minghui; Dai Jianrong; Wang Shi

    2011-01-01

    In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform, an image quality phantom, and a kV X-ray CBCT. A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction, separately or together, was simulated by considering different respiration amplitudes, periods and hysteresis. The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility, geometric accuracy, spatial resolution and uniformity of CT values. The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction, and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis. The CBCT image quality and its characteristics influenced by the respiration motion, and may be exploited in finding solutions. (authors)

  20. CT findings of leg muscles in the hemiplegics due to cerebrovascular accidents

    International Nuclear Information System (INIS)

    Odajima, Natsu; Ishiai, Sumio; Okiyama, Ryouichi; Furukawa, Tetsuo; Tsukagoshi, Hiroshi.

    1987-01-01

    Muscle wastings in hemiplegics due to cerebrovascular accidents were studied with CT scanning in the mid-portion of the thigh and largest-diameter section of the calf bilaterally. Muscle size and average CT density of muscle were measured. The 80 patients were classified into one of the following three stages of disability, i.e. stage 1, severely disabled (wheel-chair-bound but capable of self care [20 patients]); stage 2, moderately disabled (poorly ambulatory [41 patients]); and stage 3, mildly disabled (well ambulatory [19 patients]). Muscle cross-sectional area and CT density in both legs of non-ambulatory patients were smaller and lower than those of other groups. The atrophic change was marked in the affected side, but it was also noticeable in the non-affected side. Gracilis muscle was relatively well spared in all 3 stages. These CT findings of hemiplegics were similar to those of disuse atropy in patients with knee or hip joint lesions. Atrophy was seen first in the quadriceps in thigh and flexor muscle group in calf. These findings were similar to the systemic myogenic or neurogenic atrophies. Although gracilis and sartorius muscles were spared in these systemic deseases, only gracilis muscle was spared in hemiplegics and in patients with disuse atrophy. The ratios of the size of quadriceps, adductor group and sartorius muscle of thigh in affected side to that of non-affected side were smaller in more severely disabled group. Those of the other muscles showed no differences among each stages. In stage 3, there was significant negative correlation between the ratio of quadriceps muscle and periods from the attack. There was no relationship between the severity of the muscle atrophy and parietal lobe lesion. The atrophy is considered to be the result of disuse from immobilization. (author)

  1. CT-guided radiolabelled aerosol studies for assessing pulmonary impairment in children with bronchiectasis

    International Nuclear Information System (INIS)

    Pifferi, M.; Baldini, M.; Caramella, D.; Bartolozzi, C.; Di Mauro, M.; Cangiotti, A.M.

    2000-01-01

    Objective. To determine whether CT-guided mucociliary clearance studies allow differentiation between bronchiectasis associated with primary ciliary dyskinesia (PCD) and those unrelated to congenital or genetically transmitted defects. Materials and methods. Fifteen children aged 4-18 years with a CT diagnosis of bronchiectasis were included in the study. Six had PCD, while in nine cases no congenital disorder was demonstrated. Results. CT showed bronchiectasis in 26 (29 %) of 90 lung regions. Radiolabelled aerosol studies were conducted globally for each lung and on the regions affected by bronchiectasis. Global half-time of activity (t 1/2 ) values of patients with PCD were significantly higher (P 1/2 values. Patients with bronchiectasis unrelated to congenital disorders showed significantly higher regional t 1/2 values in the affected regions with respect to the corresponding global pulmonary t 1/2 (P < 0.06). Conclusions. The combination of morphological CT information with functional data concerning the clearance of radiolabelled aerosol adds to our understanding of pulmonary impairment in children with bronchiectasis. In particular, regional studies allow the recognition of different mucociliary clearance patterns in bronchiectasis associated with PCD and those unrelated to congenital or genetically transmitted defects. (orig.)

  2. Chest CT findings in pediatric Wegener's granulomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Levine, Daniel [British Columbia Children' s Hospital, Department of Radiology and Nuclear Medicine, Vancouver, British Columbia (Canada); Akikusa, Jonathan [Royal Children' s Hospital Melbourne, Department of Rheumatology, Melbourne (Australia); Manson, David [Hospital for Sick Children, Department of Radiology, Toronto (Canada); Silverman, Earl; Schneider, Rayfel [Hospital for Sick Children, Department of Rheumatology, Toronto (Canada)

    2007-01-15

    Although pulmonary involvement occurs in the majority of children and adolescents with Wegener's granulomatosis (WG), relatively little has been published regarding the CT imaging manifestations in this group of patients. To determine the frequency and types of chest CT abnormalities in active pediatric WG (pWG). The study was a retrospective examination of 29 chest CT examinations performed at diagnosis (n=14) and during disease flares (n=15) in 18 children. The most common abnormalities were nodules (seen in 90% of examinations), ground-glass opacification (52%), and air-space opacification (45%). Of examinations with nodules, 73% demonstrated nodules >5 mm in diameter and 69% demonstrated more than five nodules; 17% had cavitary lesions. The only abnormality with a significant difference in prevalence between diagnosis and disease flares was air-space opacification, present in 71% and 20%, respectively (P < 0.01). In accordance with the findings of published adult studies and at variance with those of prior pediatric studies, our findings indicate that chest CT abnormalities in active pWG are frequent, most commonly comprising nodules and ground-glass opacification, which may be difficult to detect on plain radiography. We therefore advocate the routine use of chest CT for all affected patients, both at the time of presentation and during disease flares. (orig.)

  3. Metacognitive Attributes and Liberated Progress

    Directory of Open Access Journals (Sweden)

    Mania Nosratinia

    2014-08-01

    Full Text Available Owing to the cardinal and acknowledged importance of autonomy (AU in learning, especially second-language learning, and influenced by the importance of inspecting its nature and the way it is associated with other psychological/cognitive/metacognitive factors, this research investigated the relationship among English as a foreign language (EFL learners’ AU, creativity (CR, and critical thinking (CT. The population for this study comprised of undergraduate EFL learners, between the ages of 19 and 40 (Mage = 22 years, from which 182 male and female subjects were selected via random selection. These participants, who were receiving formal instruction mainly through English, filled out three questionnaires related to CR, CT, and AU. Pearson’s product–moment correlation coefficient was used to analyze the data obtained. The results indicated that there is a significant and positive relationship between EFL learners’ CR and AU, CR and CT, as well as their CT and AU. Considering AU as the predicted variable for this study, it was confirmed that CT makes the strongest unique contribution to explain AU. It is hoped that the results of this study will reveal the nature of AU more and will equip EFL teachers with a wider perspective on the characteristics of AU and the way CR and CT can predict and promote AU among EFL learners.

  4. Wide field of view CT and acromioclavicular joint instability: A technical innovation.

    Science.gov (United States)

    Dyer, David R; Troupis, John M; Kamali Moaveni, Afshin

    2015-06-01

    A 21-year-old female with a traumatic shoulder injury is investigated and managed for symptoms relating to this injury. Pathology at the acromioclavicular joint is detected clinically; however, clinical examination and multiple imaging modalities do not reach a unified diagnosis on the grading of this acromioclavicular joint injury. When management appropriate to that suggested injury grading fail to help the patient's symptoms, further investigation methods were utilised. Wide field of view, dynamic CT (4D CT) is conducted on the patient's affected shoulder using a 320 × 0.5 mm detector multislice CT. Scans were conducted with a static table as the patient completed three movements of the affected shoulder. Capturing multiple data sets per second over a z-axis of 16 cm, measurements of the acromioclavicular joint were made, to show dynamic changes at the joint. Acromioclavicular (AC) joint translations were witnessed in three planes (a previously unrecognised pathology in the grading of acromioclavicular joint injuries). Translation in multiple planes was also not evident on careful clinical examination of this patient. AC joint width, anterior-posterior translation, superior-inferior translation and coracoclavicular width were measured with planar reconstructions while volume-rendered images and dynamic sequences aiding visual understanding of the pathology. Wide field of view dynamic CT (4D CT) is an accurate and quick modality to diagnose complex acromioclavicular joint injury. It provides dynamic information that no other modality can; 4D CT shows future benefits for clinical approach to diagnosis and management of acromioclavicular joint injury, and other musculoskeletal pathologies. © 2015 The Royal Australian and New Zealand College of Radiologists.

  5. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  6. Tillage, fertilization systems and chemical attributes of a Paleudult

    Directory of Open Access Journals (Sweden)

    Evelyn Penedo Dorneles

    2015-02-01

    Full Text Available Tillage and fertilization methods may affect soil fertility. With the aim of assessing changes in soil chemical properties over a period of ten years, soil samples of a Paleudult were collected over nine seasons at three layer depths (0-5, 5-10, 10-20 cm and were chemically analyzed. Grain yield and nutrient export in two summer crops, soybean (Glycine max and corn (Zea mays, in a field experiment set in Eldorado do Sul, in the state of Rio Grande do Sul, Brazil, were determined. Three soil tillage systems were evaluated, conventional (CT, reduced (RT and no-tillage (NT, combined with mineral (lime and fertilizers and organic (poultry litter fertilization. The no-tillage system stood out as compared to the others, especially in the surface layer, in terms of values of organic matter, soil pH, available phosphorus, cation exchange capacity and base saturation. Phosphorus content was higher under organic than mineral fertilization due to the criteria used for the establishment of fertilizer doses. Under organic fertilization, soil pH values were similar to those obtained in limed soil samples because of the cumulative effect of the organic fertilizer. Soybean yield was lower under NT in comparison to the RT and CT systems. Consequently, soybean grain exported a lower content of nutrients than maize grain. Maize yield was not affected by either tillage or fertilization systems.

  7. Searchable attribute-based encryption scheme with attribute revocation in cloud storage.

    Science.gov (United States)

    Wang, Shangping; Zhao, Duqiao; Zhang, Yaling

    2017-01-01

    Attribute based encryption (ABE) is a good way to achieve flexible and secure access control to data, and attribute revocation is the extension of the attribute-based encryption, and the keyword search is an indispensable part for cloud storage. The combination of both has an important application in the cloud storage. In this paper, we construct a searchable attribute-based encryption scheme with attribute revocation in cloud storage, the keyword search in our scheme is attribute based with access control, when the search succeeds, the cloud server returns the corresponding cipher text to user and the user can decrypt the cipher text definitely. Besides, our scheme supports multiple keywords search, which makes the scheme more practical. Under the assumption of decisional bilinear Diffie-Hellman exponent (q-BDHE) and decisional Diffie-Hellman (DDH) in the selective security model, we prove that our scheme is secure.

  8. WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, B; Marshall, H; Hughes, P; Stewart, N; Horn, F; Collier, G; Norquay, G; Hart, K; Swinscoe, J; Hatton, M; Wild, J; Ireland, R [University of Sheffield, Sheffield (United Kingdom)

    2016-06-15

    Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CT and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.

  9. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  10. Role of CT in hybrid imaging. Point of view of the medical physicist

    International Nuclear Information System (INIS)

    Gardin, I.; Hapdey, S.

    2010-01-01

    The recent introduction of hybrid systems SPECT/CT and PET/CT in nuclear medicine, greatly improved the diagnostic accuracy for particular clinical indications, due to the possible attenuation correction of functional images and the availability of helpful anatomic information. The introduction of CT in the nuclear diagnostic process results in a significant increase of the patient dose. This increase should be justified and optimized considering both the clinical question and the CT settings available on these systems. The choice of CT settings directly affects the effective dose. It varies basically as the square of the tube voltage, linearly with the length of the scan and the product of the current by the rotation time of the tube. It is also inversely proportional to the pitch. For attenuation correction, the literature shows that it is possible to use a low CT tube current without significant effect on tumor FDG uptake or lesion size. Conversely low CT voltage must be used with caution, depending on the algorithm implemented in the CT hybrid device to transform CT Hounsfield units to the attenuation map at the appropriate energy. The radiation dose for anatomic correlation can be substantially lower than for diagnostic-quality CT. It is possible to reduce the patient's radiation dose by a factor of 2 or 3 by acquiring a low-dose PET/CT scan for anatomic correlation of adequate image quality if compared with diagnostic 18 FDG PET/CT. Using specific CT settings, the effective dose can range 7.3-11.3 mSv depending on the patient weight and age. (authors)

  11. Spiral CT scanning plan to generate accurate Fe models of the human femur

    International Nuclear Information System (INIS)

    Zannoni, C.; Testi, D.; Capello, A.

    1999-01-01

    In spiral computed tomography (CT), source rotation, patient translation, and data acquisition are continuously conducted. Settings of the detector collimation and the table increment affect the image quality in terms of spatial and contrast resolution. This study assessed and measured the efficacy of spiral CT in those applications where the accurate reconstruction of bone morphology is critical: custom made prosthesis design or three dimensional modelling of the mechanical behaviour of long bones. Results show that conventional CT grants the highest accuracy. Spiral CT with D=5 mm and P=1,5 in the regions where the morphology is more regular, slightly degrades the image quality but allows to acquire at comparable cost an higher number of images increasing the longitudinal resolution of the acquired data set. (author)

  12. Getting off on the Wrong Foot: Longitudinal Effects of Hispanic Students' Stability Attributions Following Poor Initial Test Performance

    Science.gov (United States)

    Cox, Cody B.; Yang, Yan

    2012-01-01

    Though studies have established that following poor performance, attributions to stable causes affect the performance of minority students, few studies have explored the impact of stability attributions over time. This study explored attributions following initial failure among a predominantly Hispanic student population. We measured students'…

  13. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  14. Attributional processes in the learned helplessness paradigm: behavioral effects of global attributions.

    Science.gov (United States)

    Mikulincer, M

    1986-12-01

    Following the learned helplessness paradigm, I assessed in this study the effects of global and specific attributions for failure on the generalization of performance deficits in a dissimilar situation. Helplessness training consisted of experience with noncontingent failures on four cognitive discrimination problems attributed to either global or specific causes. Experiment 1 found that performance in a dissimilar situation was impaired following exposure to globally attributed failure. Experiment 2 examined the behavioral effects of the interaction between stable and global attributions of failure. Exposure to unsolvable problems resulted in reduced performance in a dissimilar situation only when failure was attributed to global and stable causes. Finally, Experiment 3 found that learned helplessness deficits were a product of the interaction of global and internal attribution. Performance deficits following unsolvable problems were recorded when failure was attributed to global and internal causes. Results were discussed in terms of the reformulated learned helplessness model.

  15. Patient doses in CT with special emphasis on pediatric patients in Algeria

    International Nuclear Information System (INIS)

    Khelassi-Toutaoui, Nadia; Merad, Ahmed; Toutaoui, Aek; Bairi, Souad; Tsapaki, Virginia; Mansouri, Boudjema

    2008-01-01

    Full text: Purpose: To estimate the frequency of CT examinations in children 0-15 years of age, to investigate whether exposure factors for children are different than for adults and to evaluate patient dose, as part of an International Atomic Energy Agency (IAEA) project on Radiation Protection of patients and Medical Exposure Control (RAF 9033). Material and Methods: Two CT machines were included in the study. Weighted computed tomography dose index (CTDI w ). Results: Pediatric CT examinations accoutered for 12-20% of the total exams performed in the CT facilities. For head, chest and abdomen examinations, mAs were reduced for pediatric patients, mainly on an arbitrary manner. One of the CT machines allowed change of kV and in that case kV was reduced for pediatric patients. Chest, Chest-High Resolution, Abdomen, Lumbar spine and Pelvis CTDI w and DLP were lower and IAEA guidance levels in almost all types of exams. It was observed, however, that DLP in one hospital was almost double than the other hospital that was mostly attributed to larger extent of scan length. ) for a single slice and dose length product (DLP) for a complete examination were used to evaluate patient dose. Kilovoltage (kV) and mAs were the exposure factors investigated. Conclusion: The study showed that pediatric examinations reach up to 1/5 of the total exams performed. It is encouraging that exposure factors are reduced, but a more standard method of reduction should be applied. Patient doses were lower that IAEA standards. Further optimization could be done by reducing scan length. (author)

  16. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  17. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  18. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  19. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  20. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children

    International Nuclear Information System (INIS)

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-01-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children. (orig.)

  1. Main Quality Attributes of Monoclonal Antibodies and Effect of Cell Culture Components

    Science.gov (United States)

    Torkashvand, Fatemeh; Vaziri, Behrouz

    2017-05-01

    The culture media optimization is an inevitable part of upstream process development in therapeutic monoclonal antibodies (mAbs) production. The quality by design (QbD) approach defines the assured quality of the final product through the development stage. An important step in QbD is determination of the main quality attributes. During the media optimization, some of the main quality attributes such as glycosylation pattern, charge variants, aggregates, and low-molecular-weight species, could be significantly altered. Here, we provide an overview of how cell culture medium components affects the main quality attributes of the mAbs. Knowing the relationship between the culture media components and the main quality attributes could be successfully utilized for a rational optimization of mammalian cell culture media for industrial mAbs production.

  2. Crop Evaluation System Optimization: Attribute Weights Determination Based on Rough Sets Theory

    Directory of Open Access Journals (Sweden)

    Ruihong Wang

    2017-01-01

    Full Text Available The present study is mainly a continuation of our previous study, which is about a crop evaluation system development that is based on grey relational analysis. In that system, the attribute weight determination affects the evaluation result directly. Attribute weight is usually ascertained by decision-makers experience knowledge. In this paper, we utilize rough sets theory to calculate attribute significance and then combine it with weight given by decision-maker. This method is a comprehensive consideration of subjective experience knowledge and objective situation; thus it can acquire much more ideal results. Finally, based on this method, we improve the system based on ASP.NET technology.

  3. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  4. Value of PET-CT and PET-CT combined with lung VCAR software in the diagnosis of hilar area lymph nodes of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Yu Lijuan; Li Yingci; Wang Wenzhi; Wang Xin; Lu Pei'ou; Tian Mohan

    2012-01-01

    Objective: To explore the diagnostic value of PET-CT and PET-CT combined with lung volume computed assisted reading (Lung VCAR) software in hilar area lymph nodes. Methods: Preoperative whole body PET-CT imaging was performed in 49 patients who were highly suspicious of non-small cell lung cancer. PET-CT images of the hilar area lymph nodes and the PET-CT images of the hilar area lymph nodes from Lung VCAR software were evaluated by two experienced doctors, and then compared with the pathological diagnosis. Results: There was no significant difference between the CT values of benign and malignant lymph nodes (t=-1.40, P>0.05). But a significant difference was existed between the benign and malignant hilar lymph nodes with the density visual analysis, the lymph short diameter and the maximum of standardized uptake value (SUV max ) (χ 2 =30.37, 27.40, 20.06, all P<0.05). The sensibility,specificity and accuracy of PET-CT in diagnosis of the hilar area lymph nodes were 76.5%, 90.7%, 88.3% respectively, and the accuracy of the diagnosis was significantly higher than that of CT and PET alone (χ 2 =15.27, P<0.05) using the lymph short diameter ≥1 cm of CT, the density of lymph node is equal to (slightly lower than) the same layer vascular density and the lymph node SUV max ≥2.5 of PET as the diagnostic criteria. One hundred and three hilar area lymph nodes were diagnosed by PET-CT and four nodes were not hilar lymph nodes proved by the Lung VCAR software (3 hilar vascular uptake,1 bronchial cartilage). Conclusion: The methods of PET-CT lymph visual density analysis plus lymph node diameter and SUV max had a high diagnostic accuracy of non-small cell lung hilar lymph. For the PET-CT,the pulmonary vascular uptake was the main cause affecting the discrimination of hilar lymph nodes,while Lung VCAR software was helpful to diagnosis. (authors)

  5. GIANT CELL AORTITIS DIAGNOSED WITH PET/CT - PARANEOPLASTIC SYNDROME?

    Science.gov (United States)

    Bakula, Marija; Cerovec, Mislav; Mayer, Miroslav; Huić, Dražen; Anić, Branimir

    2016-05-01

    Vasculitides are heterogenic group of autoimmune connective tissue diseases which often present difficulties in early diagnosing. Giant cell arteritis is vasculitis of large and medium arteries. It predominantly presents with symptoms of affection of the external carotid artery branches. Furthermore, the only symptoms can be constitutional. In clinical practice, vasculitides are sometimes considered as paraneoplastic, but no definite association with malignancies has been established and the mechanisms are still debated. The gold standard for diagnosing giant cell arteritis is a positive temporal artery biopsy, but the results can often be false negative. Additionally, more than half of the patients have aorta and its main branches affected. Considering aforementioned, imaging studies are essential in confirming large-vessel vasculitis, amongst which is highly sensitive PET/CT. We present the case of a 70-year-old female patient with constitutional symptoms and elevated sedimentation rate. After extensive diagnostic tests, she was admitted to our Rheumatology unit. Aortitis of the abdominal aorta has been confirmed by PET/CT and after the introduction of glucocorticoids the disease soon went into clinical and laboratory remission. Shortly after aortitis has been diagnosed, lung carcinoma was revealed of which the patient died. At the time of the comprehensive diagnostics, there was no reasonable doubt for underlying malignoma. To the best of our knowledge, there are no recent publications concerning giant cell arteritis and neoplastic processes in the context of up-to-date non-invasive diagnostic methods (i.e. PET/CT). In the light of previous research results, we underline that the sensitivity of PET/CT is not satisfactory when estimating cancer dissemination in non-enlarged lymph nodes and that its value can at times be overestimated.

  6. Registered error between PET and CT images confirmed by a water model

    International Nuclear Information System (INIS)

    Chen Yangchun; Fan Mingwu; Xu Hao; Chen Ping; Zhang Chunlin

    2012-01-01

    The registered error between PET and CT imaging system was confirmed by a water model simulating clinical cases. A barrel of 6750 mL was filled with 59.2 MBq [ 18 F]-FDG and scanned after 80 min by 2 dimension model PET/CT. The CT images were used to attenuate the PET images. The CT/PET images were obtained by image morphological processing analyses without barrel wall. The relationship of the water image centroids of CT and PET images was established by linear regression analysis, and the registered error between PET and CT image could be computed one slice by one slice. The alignment program was done 4 times following the protocol given by GE Healthcare. Compared with centroids of water CT images, centroids of PET images were shifted to X-axis (0.011slice+0.63) mm, to Y-axis (0.022×slice+1.35) mm. To match CT images, PET images should be translated along X-axis (-2.69±0.15) mm, Y-axis (0.43±0.11) mm, Z-axis (0.86±0.23) mm, and X-axis be rotated by (0.06±0.07)°, Y-axis by (-0.01±0.08)°, and Z-axis by (0.11±0.07)°. So, the systematic registered error was not affected by load and its distribution. By finding the registered error between PET and CT images for coordinate rotation random error, the water model could confirm the registered results of PET-CT system corrected by Alignment parameters. (authors)

  7. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  9. Role of respiratory-gated PET/CT for pancreatic tumors: A preliminary result

    International Nuclear Information System (INIS)

    Kasuya, Takeo; Tateishi, Ukihide; Suzuki, Kazufumi; Daisaki, Hiromitsu; Nishiyama, Yuji; Hata, Masaharu; Inoue, Tomio

    2013-01-01

    Purpose: The aim of this study is to ascertain role of respiratory-gated PET/CT for accurate diagnosis of pancreatic tumors. Materials and methods: Prior to clinical study, the phantom study was performed to evaluate the impact of respiratory motion on lesion quantification. Twenty-two patients (mean age 65 years) with pancreatic tumors were enrolled. Pathological diagnoses by surgical specimens consisted of pancreatic cancer (n = 15) and benign intraductal papillary mucinous neoplasm (IPMN, n = 7). Whole-body scan of non-respiratory-gated PET/CT was performed at first, and subsequent respiratory-gated PET/CT for one bed position was performed. All PET/CT studies were performed prior to surgery. The SUV max obtained by non-respiratory-gated PET/CT and respiratory-gated PET/CT, and percent difference in SUVmax (%SUVmax) were compared. Results: The profile curve of 5 respiratory bin image was most similar to that of static image. The third bin of 5 respiratory bin image showed highest FWHM (24.0 mm) and FWTM (32.7 mm). The mean SUVmax of pancreatic cancer was similar to that of benign IPMN on non-respiratory-gated PET/CT (p = 0.05), whereas significant difference was found between two groups on respiratory-gated PET/CT (p = 0.016). The mean %SUV of pancreatic cancer was greater than that of benign IPMN (p < 0.0001). Identification of the primary tumor in pancreatic head (n = 13, 59%) was improved by using respiratory-gated PET/CT because of minimal affection of physiological accumulation in duodenum. Conclusion: Respiratory-gated PET/CT is a feasible technique for evaluation of pancreatic tumors and allows more accurate identification of pancreatic tumors compared with non-respiratory-gated PET/CT

  10. Impacts of Situational Factors on Process Attribute Uses for Food Purchases

    DEFF Research Database (Denmark)

    Loebnitz, Natascha; Mueller Loose, Simone; Grunert, Klaus G

    2015-01-01

    Consumer buying decisions for food reflect considerations about food production. However, consumers’ interest in process-related product characteristics does not always translate into buying intentions. The present study investigates how situational factors affect the use of process......-related considerations when consumers select food products. A conjoint study provides estimated part worth utilities for product alternatives that differ on five product attributes (including four process-related factors) across two products (bread and sports drink) that differ on perceived naturalness....... The investigation of the utilities of the process-related attributes features both an internal (priming of environmental values/ value centrality) and an external (time pressure) situational factor. The results indicate that the importance of process-related attributes is product specific and also depends...

  11. Attributional style and depressive symptoms in a male prison sample

    Science.gov (United States)

    O’Sullivan, Danny J.; O’Sullivan, Maura E.; O’Connell, Brendan D.; O’Reilly, Ken; Sarma, Kiran M.

    2018-01-01

    The reformulated learned helplessness model proposes that people who tend to make internal, stable, and global attributions in response to uncontrollable aversive events are more likely to develop depression. The present study sought to investigate the nature of the relationship between attributional style and depression in a male prison sample. One hundred and one adult male prisoners from four medium security prisons in Ireland completed the Attributional Style Questionnaire and measures of depression (BDI-II) and anxiety (BAI). Severity of self-reported depressive symptoms in the present sample was comparable to other prison and clinical samples, but higher than community samples. Participants were more severely affected by depressive symptoms than anxiety. The original attributional dimensions (i.e. internal, stable, and global) predicted a significant amount of variance in depression, but the model was not significant after controlling for anxiety. A subsequent regression model, comprising attributional dimensions for both negative events and positive events including a measure of ‘uncontrollability’, accounted for 35% of the variance in depression and the model retained significance while controlling for anxiety. An attributional model of depression may be relevant to the prison population and could provide a valid insight into the development and treatment of depressive symptoms in prisoners. The findings are interpreted in relation to previous research and implications for theory, clinical practice, and rehabilitation are discussed. PMID:29444084

  12. Attributional style and depressive symptoms in a male prison sample.

    Directory of Open Access Journals (Sweden)

    Danny J O'Sullivan

    Full Text Available The reformulated learned helplessness model proposes that people who tend to make internal, stable, and global attributions in response to uncontrollable aversive events are more likely to develop depression. The present study sought to investigate the nature of the relationship between attributional style and depression in a male prison sample. One hundred and one adult male prisoners from four medium security prisons in Ireland completed the Attributional Style Questionnaire and measures of depression (BDI-II and anxiety (BAI. Severity of self-reported depressive symptoms in the present sample was comparable to other prison and clinical samples, but higher than community samples. Participants were more severely affected by depressive symptoms than anxiety. The original attributional dimensions (i.e. internal, stable, and global predicted a significant amount of variance in depression, but the model was not significant after controlling for anxiety. A subsequent regression model, comprising attributional dimensions for both negative events and positive events including a measure of 'uncontrollability', accounted for 35% of the variance in depression and the model retained significance while controlling for anxiety. An attributional model of depression may be relevant to the prison population and could provide a valid insight into the development and treatment of depressive symptoms in prisoners. The findings are interpreted in relation to previous research and implications for theory, clinical practice, and rehabilitation are discussed.

  13. Attributional style and depressive symptoms in a male prison sample.

    Science.gov (United States)

    O'Sullivan, Danny J; O'Sullivan, Maura E; O'Connell, Brendan D; O'Reilly, Ken; Sarma, Kiran M

    2018-01-01

    The reformulated learned helplessness model proposes that people who tend to make internal, stable, and global attributions in response to uncontrollable aversive events are more likely to develop depression. The present study sought to investigate the nature of the relationship between attributional style and depression in a male prison sample. One hundred and one adult male prisoners from four medium security prisons in Ireland completed the Attributional Style Questionnaire and measures of depression (BDI-II) and anxiety (BAI). Severity of self-reported depressive symptoms in the present sample was comparable to other prison and clinical samples, but higher than community samples. Participants were more severely affected by depressive symptoms than anxiety. The original attributional dimensions (i.e. internal, stable, and global) predicted a significant amount of variance in depression, but the model was not significant after controlling for anxiety. A subsequent regression model, comprising attributional dimensions for both negative events and positive events including a measure of 'uncontrollability', accounted for 35% of the variance in depression and the model retained significance while controlling for anxiety. An attributional model of depression may be relevant to the prison population and could provide a valid insight into the development and treatment of depressive symptoms in prisoners. The findings are interpreted in relation to previous research and implications for theory, clinical practice, and rehabilitation are discussed.

  14. (18) F-FDG PET/CT for planning external beam radiotherapy alters therapy in 11% of 581 patients

    DEFF Research Database (Denmark)

    Birk Christensen, Charlotte; Loft-Jakobsen, Annika; Munck Af Rosenschöld, Per

    2018-01-01

    BACKGROUND: (18) F-FDG PET/CT (FDG PET/CT) used in radiotherapy planning for extra-cerebral malignancy may reveal metastases to distant sites that may affect the choice of therapy. AIM: To investigate the role of FDG PET/CT on treatment strategy changes induced by the use of PET/CT as part...... planning in our institution in the year 2008. All PET/CT scans were performed with the patient in treatment position with the use of immobilization devices according to the intended radiotherapy treatment. All scans were evaluated by a nuclear medicine physician together with a radiologist to delineate PET......% of the patients for whom the PET/CT simulation scan revealed unexpected dissemination, radiotherapy was given - changed (n = 38) or unchanged (n = 13) according to the findings on the FDG PET/CT. CONCLUSION: Unexpected dissemination on the FDG PET/CT scanning performed for radiotherapy planning caused a change...

  15. The feasibility of utilizing pseudo CT-data for online MRI based treatment plan adaptation for a stereotactic radiotherapy treatment of spinal bone metastases

    International Nuclear Information System (INIS)

    Hoogcarspel, Stan J; Van der Velden, Joanne M; Lagendijk, Jan J W; Van Vulpen, Marco; Raaymakers, Bas W

    2014-01-01

    The purpose of this study was to investigate what pseudo-CT (pCT) strategy is sufficient for online MRI based treatment plan adaptation of a stereotactic treatment for spinal bone metastases. For this purpose, the dosimetric accuracy of five increasingly complex pCT strategies was evaluated using the planning CT data of 20 patients suffering from spinal metastases. For each pCT, a treatment plan was developed and simulated on both the pCT and the original CT data of the patient. The two resulting dose distributions were compared using gamma analysis of 2%/2 mm. In this paper, a Gamma Pass Rate (GPR) of ⩾95% within the Target Volume (TV) was considered clinically acceptable. We additionally demonstrated in this paper the automatic generation of each investigated pCT strategy with the use of dedicated MRI data complemented with pre-treatment CT data of a patient in treatment position. The dosimetric accuracy of a pCT increases when additional bulk densities are utilized for a pCT. However, the dosimetric accuracy of even the most complex ‘bulk density’ pCT strategy used in this study had an average GPR of only 78% within the TV. However, if information on the heterogeneous electron density distribution within the affected vertebral body was available, a clinically acceptable 99% mean GPR was observed. All pCTs could successfully be generated using the MRI data in combination with the CT data of a patient in treatment position. The results presented in this study show that a simple ‘bulk density’ pseudo-CT strategy is not feasible for online MRI based treatment plan adaptation for spinal bone metastases. However, a clinically acceptable result is generated if the information on the heterogeneous electron density (ED) distribution within the affected vertebral bone is available. Therefore, any pCT strategy for this tumor site should include a method which can estimate the heterogeneous ED of the affected vertebral bone. (paper)

  16. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  17. Thoracic endometriosis syndrome: CT and MRI features

    International Nuclear Information System (INIS)

    Rousset, P.; Rousset-Jablonski, C.; Alifano, M.; Mansuet-Lupo, A.; Buy, J.-N.; Revel, M.-P.

    2014-01-01

    Thoracic endometriosis is considered to be rare, but is the most frequent form of extra-abdominopelvic endometriosis. Thoracic endometriosis syndrome affects women of reproductive age. Diagnosis is mainly based on clinical findings, which can include catamenial pneumothorax and haemothorax, non-catamenial endometriosis-related pneumothorax, catamenial haemoptysis, lung nodules, and isolated catamenial chest pain. Symptoms are typically cyclical and recurrent, with a right-sided predominance. Computed tomography (CT) is the first-line imaging method, but is poorly specific; therefore, its main role is to rule out other pulmonary diseases. However, in women with a typical clinical history, some key CT findings may help to confirm this often under-diagnosed syndrome. MRI can also assist with the diagnosis, by showing signal changes typical of haemorrhage within diaphragmatic or pleural lesions

  18. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  19. Core affect and the psychological construction of emotion.

    Science.gov (United States)

    Russell, James A

    2003-01-01

    At the heart of emotion, mood, and any other emotionally charged event are states experienced as simply feeling good or bad, energized or enervated. These states--called core affect--influence reflexes, perception, cognition, and behavior and are influenced by many causes internal and external, but people have no direct access to these causal connections. Core affect can therefore be experienced as free-floating (mood) or can be attributed to some cause (and thereby begin an emotional episode). These basic processes spawn a broad framework that includes perception of the core-affect-altering properties of stimuli, motives, empathy, emotional meta-experience, and affect versus emotion regulation; it accounts for prototypical emotional episodes, such as fear and anger, as core affect attributed to something plus various nonemotional processes.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  1. Valuing Attributes of Fluid Milk in Laos

    OpenAIRE

    Jae Won Lee; Taeyoon Kim; Viengsakoun Napasirth

    2017-01-01

    This study estimates the random utility function of fluid milk using 1,165 survey responses in Laos. It finds that both products’ attributes and individual characteristics affect consumers’ preference for the milk and the hypothetical brand of Laos-Korea has a potential compared to four real dairy products. Results also show that calories have a positive relationship with consumer’s preference while the price and fat content have a negative one. The decision for choosing each brand is signifi...

  2. The importance of choice attributes and the positions of the airlines ...

    African Journals Online (AJOL)

    1Consumers base their purchase decisions and behaviour on their own ... product, price, place and promotion – should be designed to add up to the .... airline industry, few studies have looked at the attributes affecting domestic airline choice ...

  3. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  4. Attribute And-Or Grammar for Joint Parsing of Human Pose, Parts and Attributes.

    Science.gov (United States)

    Park, Seyoung; Nie, Xiaohan; Zhu, Song-Chun

    2017-07-25

    This paper presents an attribute and-or grammar (A-AOG) model for jointly inferring human body pose and human attributes in a parse graph with attributes augmented to nodes in the hierarchical representation. In contrast to other popular methods in the current literature that train separate classifiers for poses and individual attributes, our method explicitly represents the decomposition and articulation of body parts, and account for the correlations between poses and attributes. The A-AOG model is an amalgamation of three traditional grammar formulations: (i)Phrase structure grammar representing the hierarchical decomposition of the human body from whole to parts; (ii)Dependency grammar modeling the geometric articulation by a kinematic graph of the body pose; and (iii)Attribute grammar accounting for the compatibility relations between different parts in the hierarchy so that their appearances follow a consistent style. The parse graph outputs human detection, pose estimation, and attribute prediction simultaneously, which are intuitive and interpretable. We conduct experiments on two tasks on two datasets, and experimental results demonstrate the advantage of joint modeling in comparison with computing poses and attributes independently. Furthermore, our model obtains better performance over existing methods for both pose estimation and attribute prediction tasks.

  5. Risk-related 18F-FDG PET/CT and new diagnostic strategies in patients with solitary pulmonary nodule: the ITALIAN multicenter trial.

    Science.gov (United States)

    Spadafora, Marco; Pace, Leonardo; Evangelista, Laura; Mansi, Luigi; Del Prete, Francesco; Saladini, Giorgio; Miletto, Paolo; Fanti, Stefano; Del Vecchio, Silvana; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Nicolai, Emanuele; Storto, Giovanni; Ferdeghini, Marco; Giordano, Alessandro; Farsad, Mohsen; Schillaci, Orazio; Gridelli, Cesare; Cuocolo, Alberto

    2018-05-05

    Diagnosis of solitary pulmonary nodule (SPN) is an important public health issue and 18 F-FDG PET/CT has proven to be more effective than CT alone. Pre-test risk stratification and clinical presentation of SPN could affect the diagnostic strategy. A relevant issue is whether thoracic segmental (s)-PET/CT could be implemented in patients with SPN. This retrospective multicenter study compared the results of FDG whole-body (wb)-PET/CT to those of s-PET/CT. 18 F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. The thoracic part of wb-PET/CT, considered s-PET/CT, was compared to wb-PET/CT. Clinical and PET/CT variables were investigated for SPN characterization as well as for identification of patients in whom s-PET/CT could be performed. Histopathology or follow-up data were used as a reference. In the study population, 36% had malignant, 35% benign, and 29% indeterminate SPN. 18 F-FDG uptake indicative of thoracic and extra-thoracic lesions was detectable in 13% and 3% of the patients. All patients with extra-thoracic metastases (n = 13) had thoracic lymph node involvement and highest 18 F-FDG uptake at level of SPN (negative predictive value 100%). Compared to wb-PET/CT, s-PET/CT could save about 2/3 of 18 F-FDG dose, radiation exposure or scan-time, without affecting the clinical impact of PET/CT. Pre-test probability of malignancy can guide the diagnostic strategy of 18 FDG-PET/CT in patients with SPN. In subjects with low-intermediate pretest probability s-PET/CT imaging might be planned in advance, while in those at high risk and with thoracic lymph node involvement a wb-PET/CT is necessary.

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  7. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  8. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  9. Use of high concentration contrast media (HCCM): principles and rationale--body CT

    International Nuclear Information System (INIS)

    Brink, James A.

    2003-01-01

    Numerous complex pharmacokinetic interrelationships affect the use of contrast media for computed tomography (CT) imaging. The volume, concentration, and rate of injection, all affect the degree of enhancement that is achieved with an injection of contrast material. In addition, the injection technique, whether the contrast is infused with a constant injection rate (uniphasic injection) or whether the rate is altered during the injection (multiphasic injection) also affect the magnitude and duration of contrast enhancement. In body CT imaging, the liver poses unique challenges in managing the use of intravenous contrast material because of its dual blood supply and the need to complete imaging before equilibrium occurs between the intravascular and extravascular compartments. The magnitude of hepatic enhancement that is ultimately achieved is related primarily to the amount of iodinated contrast material that accumulates in the extravascular space within the target organ, independent of the speed of the CT scanner. The key determinant of the onset of the equilibrium phase is the injection duration. Given that a high injection flow rate (4-5 ml/s) is desirable for arterial phase imaging, the injection duration is maintained with use of an appropriate contrast volume. Thus, modifications of total iodine dose are best done with alterations in contrast concentration. The magnitude of arterial enhancement that is achieved is related to both the concentration and rate of contrast administration. The speed of the scanner determines its ability to record image data during the most advantageous time period, the peak of arterial enhancement. Thus, rapid imaging is particularly advantageous for optimal contrast use in CT angiography as well as in multiphasic imaging of the parenchymal organs

  10. A semantic framework to protect the privacy of electronic health records with non-numerical attributes.

    Science.gov (United States)

    Martínez, Sergio; Sánchez, David; Valls, Aida

    2013-04-01

    Structured patient data like Electronic Health Records (EHRs) are a valuable source for clinical research. However, the sensitive nature of such information requires some anonymisation procedure to be applied before releasing the data to third parties. Several studies have shown that the removal of identifying attributes, like the Social Security Number, is not enough to obtain an anonymous data file, since unique combinations of other attributes as for example, rare diagnoses and personalised treatments, may lead to patient's identity disclosure. To tackle this problem, Statistical Disclosure Control (SDC) methods have been proposed to mask sensitive attributes while preserving, up to a certain degree, the utility of anonymised data. Most of these methods focus on continuous-scale numerical data. Considering that part of the clinical data found in EHRs is expressed with non-numerical attributes as for example, diagnoses, symptoms, procedures, etc., their application to EHRs produces far from optimal results. In this paper, we propose a general framework to enable the accurate application of SDC methods to non-numerical clinical data, with a focus on the preservation of semantics. To do so, we exploit structured medical knowledge bases like SNOMED CT to propose semantically-grounded operators to compare, aggregate and sort non-numerical terms. Our framework has been applied to several well-known SDC methods and evaluated using a real clinical dataset with non-numerical attributes. Results show that the exploitation of medical semantics produces anonymised datasets that better preserve the utility of EHRs. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  12. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  13. Qualitative Analysis of the Impact of SOA Patterns on Quality Attributes

    NARCIS (Netherlands)

    Galster, Matthias; Avgeriou, Paris; Tang, A; Muccini, H

    2012-01-01

    Software architecture patterns are proven and reusable solutions to common architecture design problems. One characteristic of architecture patterns is that they affect quality attributes (e.g., performance, reliability). Over the past years, architecture patterns for service-based systems have been

  14. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  15. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  16. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  17. SU-G-206-03: CTDI Per KV at Phantom Center and Periphery: Comparison Between Major CT Manufacturers

    Energy Technology Data Exchange (ETDEWEB)

    Al-Senan, R [Columbia University Medical Center, New York, NY (United States); Demirkaya, O [King Faisal Specialist Hospital & Research Centre, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: The purpose of this study was to: 1) compare scanners output by measuring normalized CTDIw (mGy/100mAs) in different CT makes and models and at different kV’s, and 2) quantify the relationship between kV and CTDI and compare this relationship between the different manufacturers. Methods: Study included forty scanners of major CT manufacturers and of various models. Exposure was measured at center and 12 o’clock holes of head and body CTDI phantoms, at all available kV’s, and with the largest or second largest available collimation in each scanner. Average measured CTDI’s from each CT manufacturer were also plotted against kV and the fitting equation: CTDIw (normalized) = a.kVb was calculated. The power (b) value may be considered as an indicator of spectral filtration, which affects the degree of beam hardening. Also, HVLs were measured at several scanners. Results: Results showed GE scanners, on average, had higher normalized CTDIw than those of Siemens and Philips, in both phantom sizes and at all kV’s. ANOVA statistic indicated the difference was statistically significant (p < 0.05). Comparison between Philips and Siemens, however, was not statistically significant. Curve fitting showed b values ranged from 2.4 to 2.9 (for Head periphery and center, respectively); and was about 2.8 for Body phantom periphery, and 3.2 at the center of Body phantom. Fitting equations (kV vs. CTDI) will be presented and discussed. GE’s CTDIw vs. HVL showed very strong correlation (r > 0.99). Conclusion: Partial characterization of scanners output was performed which may be helpful in dose estimation to internal organs. The relatively higher output from GE scanners may be attributed to lower filtration. Work is still in progress to obtain CTDI values from other scanners as well as to measure their HVLs.

  18. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  19. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  20. Role of FDG PET/CT in Baastrup's disease

    International Nuclear Information System (INIS)

    Subramanyam, Padma; Palaniswamy, Shanmuga Sundaram

    2016-01-01

    Baastrup's disease is a benign condition, which presents as chronic low back pain. It is also known as “kissing spine syndrome” and refers to close approximation of adjacent spinous processes producing inflammation and back pain. This condition is often misdiagnosed, resulting in incorrect treatment and persistence of symptoms. Diagnosis of Baastrup's disease is verified with clinical examination and imaging studies. Conventionally, clinicians resort to magnetic resonance imaging (MRI) of spine rather than X-ray or computed tomography (CT) in the evaluation of back pain. MRI can additionally identify flattening, sclerosis, enlargement, cystic lesions, and bone edema at the articulating surfaces of the two affected spinous processes. Studies have reported that 18 Fluorine fluorodeoxyglucose-positron emission tomography/CT (FDG-PET/CT) can detect a bursitis or an inflammation as a form of stress reaction despite a negative MRI and 99m Tc Methylene diphosphonate (MDP) bone scan. PET/CT is usually not a recommended investigation for this condition. However, this case report highlights the benefit of FDG-PET/CT in identifying the site of inflammatory pathology. It is also known to identify the exact site of inflammation where steroid or local anesthetic injection can be administered to alleviate pain, especially in patients with multilevel vertebral involvement

  1. Brain parenchymal density measurements by CT in demented subjects and normal controls

    International Nuclear Information System (INIS)

    Gado, M.; Danziger, W.L.; Chi, D.; Hughes, C.P.; Coben, L.A.

    1983-01-01

    Parachymal density measurements of 14 regions of gray and white matter from each cerebral hemisphere were made from CT scans of 25 subjects who had varying degrees of dementia as measured by a global Clinical Dementia Rating, and also from CT scans of 33 normal control subjects. There were few significant differences between the two groups in the mean density value for each of the regions examined, although several individual psychometric tests did correlate with density changes. Moreover, for six regions in the cerebral cortex, and for one region in the thalamus of each hemisphere, we found no significant correlation between the gray-white matter density difference and dementia. There was, however, a loss of the discriminability between the gray and white matter with an increase in the size of the ventricles. These findings may be attributed to the loss of white matter volume

  2. Towards incorporating affective computing to virtual rehabilitation; surrogating attributed attention from posture for boosting therapy adaptation

    Science.gov (United States)

    Rivas, Jesús J.; Heyer, Patrick; Orihuela-Espina, Felipe; Sucar, Luis Enrique

    2015-01-01

    Virtual rehabilitation (VR) is a novel motor rehabilitation therapy in which the rehabilitation exercises occurs through interaction with bespoken virtual environments. These virtual environments dynamically adapt their activity to match the therapy progress. Adaptation should be guided by the cognitive and emotional state of the patient, none of which are directly observable. Here, we present our first steps towards inferring non-observable attentional state from unobtrusively observable seated posture, so that this knowledge can later be exploited by a VR platform to modulate its behaviour. The space of seated postures was discretized and 648 pictures of acted representations were exposed to crowd-evaluation to determine attributed state of attention. A semi-supervised classifier based on Na¨ıve Bayes with structural improvement was learnt to unfold a predictive relation between posture and attributed attention. Internal validity was established following a 2×5 cross-fold strategy. Following 4959 votes from crowd, classification accuracy reached a promissory 96.29% (µ±σ = 87.59±6.59) and F-measure reached 82.35% (µ ± σ = 69.72 ± 10.50). With the afforded rate of classification, we believe it is safe to claim posture as a reliable proxy for attributed attentional state. It follows that unobtrusively monitoring posture can be exploited for guiding an intelligent adaptation in a virtual rehabilitation platform. This study further helps to identify critical aspects of posture permitting inference of attention.

  3. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  4. The double-edged sword of genetic accounts of criminality: causal attributions from genetic ascriptions affect legal decision making.

    Science.gov (United States)

    Cheung, Benjamin Y; Heine, Steven J

    2015-12-01

    Much debate exists surrounding the applicability of genetic information in the courtroom, making the psychological processes underlying how people consider this information important to explore. This article addresses how people think about different kinds of causal explanations in legal decision-making contexts. Three studies involving a total of 600 Mechanical Turk and university participants found that genetic, versus environmental, explanations of criminal behavior lead people to view the applicability of various defense claims differently, perceive the perpetrator's mental state differently, and draw different causal attributions. Moreover, mediation and path analyses highlight the double-edged nature of genetic attributions-they simultaneously reduce people's perception of the perpetrator's sense of control while increasing people's tendencies to attribute the cause to internal factors and to expect the perpetrator to reoffend. These countervailing relations, in turn, predict sentencing in opposite directions, although no overall differences in sentencing or ultimate verdicts were found. © 2015 by the Society for Personality and Social Psychology, Inc.

  5. Rod displacement measurements by x-ray CT and its impact on thermal-hydraulics in tight-lattice rod bundle (Joint research)

    International Nuclear Information System (INIS)

    Mitsutake, Toru; Misawa, Takeharu; Kureta, Masatoshi; Akimoto, Hajime

    2005-06-01

    In tight-lattice simulated rod bundles with about 1 mm gap between rods, a rod displacement might affect thermal-hydraulic characteristics since the displacement has a strong impact on the flow area change along the heated section. It should be important to estimate how large the rod position displacement could quantitatively affect critical power for the tight-lattice rod bundle from the point of improvement of prediction capability of subchannel analysis. In the present study, the inside-structure observation of the simulated seven-rod bundle of Reduced Moderation Water Reactor (RMWR) was made through the whole length of the test assembly. Based on the measured rod position data, the relation between the rod position displacement and the heat transfer characteristics was investigated experimentally and through the two kinds of subchannel analysis, the nominal rod position case and the measured rod position case, the effect on the predicted critical power was estimated. The high-energy X-ray computer tomograph (CT) of Fuels Monitoring Facilities (FMF) at the O-arai Engineering Center in Japan Nuclear Cycle Institute (JNC) was applied for the inside-structure observation of the test assembly. The CT view of the cross sections within the test assembly assured the hexagonal rod position arrangement was almost the same as expected by design. The measured data with the X-ray CT facility showed that all rod displacements were small, 0.5 millimeters at maximum and 0.2 millimeters in average. In the heat transfer experiments for the seven-rod bundle, the boiling transition (BT) position and the rod surface temperature behavior was measured. All thermocouples on the center rod downstream from the BT-onset axial height showed almost simultaneous temperature increase due to BT. And the thermocouples located on the same axial heights showed quite similar time-variation behaviors in the vapor cooling heat transfer regime. These results demonstrated the effect of the

  6. EFFECT OF COVER CROPS ON SOIL ATTRIBUTES, PLANT NUTRITION, AND IRRIGATED TROPICAL RICE YIELD

    Directory of Open Access Journals (Sweden)

    ANDRE FROES DE BORJA REIS

    2017-01-01

    Full Text Available In flood plains, cover crops are able to alter soil properties and significantly affect rice nutrition and yield. The aims of this study were to determine soil properties, plant nutrition, and yield of tropical rice cultivated on flood plains after cover crop cultivation with conventional tillage (CT and no-tillage system (NTS at low and high nitrogen (N fertilization levels. The experimental design was a randomized block in a split-split-plot scheme with four replications. In the main plots were cover crops sunhemp (Crotalaria juncea and C. spectabilis, velvet bean (Mucuna aterrima, jackbean (Canavalia ensiformis, pigeon pea (Cajanus cajan, Japanese radish (Raphanus sativus, cowpea (Vigna unguiculata and a fallow field. In the subplots were the tillage systems (CT or NTS. The nitrogen fertilization levels in the sub-subplots were (10 kg N ha-1 and 45 kg N ha-1. All cover crops except Japanese radish significantly increased mineral soil nitrogen and nitrate concentrations. Sunhemp, velvet bean, and cowpea significantly increased soil ammonium content. The NTS provides higher mineral nitrogen and ammonium content than that by CT. Overall, cover crops provided higher levels of nutrients to rice plants in NTS than in CT. Cover crops provide greater yield than fallow treatments. Rice yield was higher in NTS than in CT, and greater at a higher rather than lower nitrogen fertilization level.

  7. Clinical application of subtraction CT imaging for evaluation of pulmonary vascular permeability

    International Nuclear Information System (INIS)

    Kato, Shiro; Asai, Toshihiko; Yatagai, Shigeo; Oonuma, Noboru; Ohno, Kunihiko; Nakamoto, Takaaki; Iizuka, Masahiko

    1991-01-01

    In this clinical study, one normal subject, one patient with primary interstitial pneumonia, one patient with segmental pneumonia due to Staphylococcus aureus, one patient with post-operative esophageal carcinoma, and two patients with mitral stenosis were studied. Dynamic CT scan images under continuous injection of low osmotic contrast medium were analyzed in series, in an attempt to evaluate vascular permeability quantitatively. The following results were obtained. Subtraction CT scan image 10 minutes after the start of contrast medium injection in two patients with pneumonia, showed a reduction of pulmonary vascular permeability following therapy. Subtraction CT scan image of the patient with post-operative esophageal carcinoma treated with 25 Gy radiation showed a discrepancy between pulmonary vascular permeability and other findings. In hemodynamically stable patients with mitral stenosis, subtraction CT images demonstrated that pulmonary vascular permeability was not affected by pulmonary congestion, irrespective of its severity. (author)

  8. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  9. Subperiosteal chondroma. Diagnostic value of CT scan imaging in two cases

    International Nuclear Information System (INIS)

    Lerais, J.M.; Auquier, F.; Baudrillard, J.C.; Durot, J.F.; Laugareil, P.; Wallays, C.; Lefort, G.; Daoud, S.; Gaillard, D.

    1988-01-01

    Results of CT scan exploration are reported in two cases of subperiosteal chondroma, one in a 4 year old child affecting the anterior tibial tuberosity the other in a 9 year old child involving the upper end of humerus. Data from CT scan imaging were undoubtedly superior to those of conventional radiography and appear to be characteristic of this benign cartilaginous tumor, greatly facilitating correlation between clinical, radiological and pathologic findings. The scanner should allow certain situations to be dedramatized and the surgical attitude adapted when the functional prognosis is involved [fr

  10. 11C-choline vs. 18F-FDG PET/CT in assessing bone involvement in patients with multiple myeloma

    Directory of Open Access Journals (Sweden)

    Ambrosini Valentina

    2007-06-01

    Full Text Available Abstract Background Multiple Myeloma (MM is a B cell neoplasm causing lytic or osteopenic bone abnormalities. Whole body skeletal survey (WBSS, Magnetic resonance (MR and 18F-FDG PET/CT are imaging techniques routinely used for the evaluation of bone involvement in MM patients. Aim As MM bone lesions may present low 18F-FDG uptake; the aim of this study was to assess the possible added value and limitations of 11C-Choline to that of 18F-FDG PET/CT in patients affected with MM. Methods Ten patients affected with MM underwent a standard 11C-Choline PET/CT and an 18F-FDG PET/CT within one week. The results of the two scans were compared in terms of number, sites and SUVmax of lesions. Results Four patients (40% had a negative concordant 11C-Choline and 18F-FDG PET/CT scans. Two patients (20% had a positive 11C-Choline and 18F-FDG PET/CT scans that identified the same number and sites of bone lesions. The remaining four patients (40% had a positive 11C-Choline and 18F-FDG PET/CT scan, but the two exams identified different number of lesions. Choline showed a mean SUVmax of 5 while FDG showed a mean SUVmax of 3.8 (P = 0.042. Overall, 11C-Choline PET/CT scans detected 37 bone lesions and 18F-FDG PET/CT scans detected 22 bone lesions but the difference was not significant (P = 0.8. Conclusion According to these preliminary data, 11C-Choline PET/CT appears to be more sensitive than 18F-FDG PET/CT for the detection of bony myelomatous lesions. If these data are confirmed in larger series of patients, 11C-Choline may be considered a more appropriate functional imaging in association with MRI for MM bone staging.

  11. Role of FDG/CT in imaging of renal lesions

    International Nuclear Information System (INIS)

    Kochhar, R.; Manoharan, P.; Brown, R.K.; Dunnick, N.R.; Frey, K.A.; Wong, C.O.

    2010-01-01

    Full text: Focal incidental renal lesions are commonly encountered on positron emission tomography (PET)/computed tomography (CT) imaging. The wast majority of these lesions are benign. However, the interpretation of renal lesions can be problematic if the imaging criteria of simple cysts are not met. Limited literature exists on the characterisation of renal masses with metabolic imaging. The purpose of this article is to focus on the imaging features of benign and malignant renal masses with PET/CT. The lesions discussed include renal cyst, angiomyolipoma, oncocytoma, renal cell carcinoma, renal metastases and other infiltrating neoplastic processes affecting the kidney. Both the anatomical and metabolic features which characterise these benign and malignant entities are described. We emphasise the importance of viewing the CT component to identify the typical morphological features and discuss how to best use hybrid imaging for management of renal lesions. Metabolic imaging has a promising role in the imaging of renal lesions and can help prevent unnecessary biopsies and ensure optimal management of suspicious lesions.

  12. Mathematical filtering minimizes metallic halation of titanium implants in MicroCT images.

    Science.gov (United States)

    Ha, Jee; Osher, Stanley J; Nishimura, Ichiro

    2013-01-01

    Microcomputed tomography (MicroCT) images containing titanium implant suffer from x-rays scattering, artifact and the implant surface is critically affected by metallic halation. To improve the metallic halation artifact, a nonlinear Total Variation denoising algorithm such as Split Bregman algorithm was applied to the digital data set of MicroCT images. This study demonstrated that the use of a mathematical filter could successfully reduce metallic halation, facilitating the osseointegration evaluation at the bone implant interface in the reconstructed images.

  13. CT imaging of necrosive fasciitis; CT-Bildgebung der nekrotisierenden Fasziitis

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, M.; Overkamp, D.; Joanoviciu, S.; Horger, M.

    2008-07-15

    NF is a rare but dramatic and often fatal infection of the fascii and adjoining soft tissues. Contrary to the Fournier's definition, it is most common in elderly people. Patients with immune problems have a higher risk (e.g. Diabetes mellitus, alcohol or drug abuse, AIDS, leukaemia, chemotherapy and immunosuppressive medication). Predisposition factors are diverticulitis, insect bites, or surgical interventions (Uppot RN, Levy HM, PLatel PH, Radiology 2003; 226; 115; Wysoki MG, Santora TA, Shah RM et al. Necrotizing fasciitis: CT characteristics, Radiology 1997; 203;859). Men are affected more frequently than women. In principle, NF may occur everywhere in the body but incidence in the region of the scrotum, perineum and lower extremities are the most common. (orig.)

  14. Invasive pulmonary aspergillosis - CT findings in context with the clinical course

    International Nuclear Information System (INIS)

    Seyfarth, H.J.; Winkler, J.; Wirtz, H.; Nenoff, P.; Krahl, R.; Kloeppel, R.; Borte, G.

    2002-01-01

    Purpose: To investigate the impact of chest radiographs and CT in patients suffering from invasive pulmonary aspergillosis (IPA) compared to the clinical course. Patients and Methods: Twenty-three patients with confirmed diagnosis of IPA between January 1996 and September 1999 were included in this study. Signs of inflammatory infiltrates on chest radiographs and CT were retrospectively evaluated in relation to the onset of the clinical symptoms. Infiltrates on CT were analyzed in detail with respect to number, morphology, and localization. Results: Seventy-six infiltrates were found on the CT of 22 patients; one patient had diffuse areas of lung infiltrates. Both lungs were affected by infiltrates in 14 patients. Pleural effusions were confirmed in 12 patients. Twelve patients had typically round foci with halo and nine patients crescent air signs. The preferred localization of lung infiltrates was segment 6. The median interval between the onset of clinical symptoms and the first radiographic changes was 5.5 days, with an additional interval of 4.5 days until confirmation by CT. Localization, number of infiltrates, and clinical course were not related. Conclusion: In immune-compromised patients with fever, a CT of the chest should be carried out as soon as possible to detect signs indicative of IPA. Morphological changes on CT like a round focus with halo and crescent air sign support the diagnosis of IPA. In this context, special attention should be directed to pulmonary segment 6. (orig.) [de

  15. Fully automated segmentation of callus by micro-CT compared to biomechanics.

    Science.gov (United States)

    Bissinger, Oliver; Götz, Carolin; Wolff, Klaus-Dietrich; Hapfelmeier, Alexander; Prodinger, Peter Michael; Tischer, Thomas

    2017-07-11

    A high percentage of closed femur fractures have slight comminution. Using micro-CTCT), multiple fragment segmentation is much more difficult than segmentation of unfractured or osteotomied bone. Manual or semi-automated segmentation has been performed to date. However, such segmentation is extremely laborious, time-consuming and error-prone. Our aim was to therefore apply a fully automated segmentation algorithm to determine μCT parameters and examine their association with biomechanics. The femura of 64 rats taken after randomised inhibitory or neutral medication, in terms of the effect on fracture healing, and controls were closed fractured after a Kirschner wire was inserted. After 21 days, μCT and biomechanical parameters were determined by a fully automated method and correlated (Pearson's correlation). The fully automated segmentation algorithm automatically detected bone and simultaneously separated cortical bone from callus without requiring ROI selection for each single bony structure. We found an association of structural callus parameters obtained by μCT to the biomechanical properties. However, results were only explicable by additionally considering the callus location. A large number of slightly comminuted fractures in combination with therapies that influence the callus qualitatively and/or quantitatively considerably affects the association between μCT and biomechanics. In the future, contrast-enhanced μCT imaging of the callus cartilage might provide more information to improve the non-destructive and non-invasive prediction of callus mechanical properties. As studies evaluating such important drugs increase, fully automated segmentation appears to be clinically important.

  16. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  17. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  18. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  19. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  20. LINC00673 rs11655237 C>T confers neuroblastoma susceptibility in Chinese population.

    Science.gov (United States)

    Zhang, Zhuorong; Chang, Yitian; Jia, Wei; Zhang, Jiao; Zhang, Ruizhong; Zhu, Jinhong; Yang, Tianyou; Xia, Huimin; Zou, Yan; He, Jing

    2018-02-28

    Neuroblastoma, which accounts for approximately 10% of all pediatric cancer-related deaths, has become a therapeutic challenge and global burden attributed to poor outcomes and mortality rates of its high-risk form. Previous genome-wide association studies (GWASs) identified the LINC00673 rs11655237 C>T polymorphism to be associated with the susceptibility of several malignant tumors. However, the association between this polymorphism and neuroblastoma susceptibility is not clear. We genotyped LINC00673 rs11655237 C>T in 393 neuroblastoma patients in comparison with 812 age-, gender-, and ethnicity-matched healthy controls. We found a significant association between the LINC00673 rs11655237 C>T polymorphism and neuroblastoma risk (TT compared with CC: adjusted odds ratio (OR) =1.80, 95% confidence interval (CI) =1.06-3.06, P =0.029; TT/CT compared with CC: adjusted OR =1.31, 95% CI =1.02-1.67, P =0.033; and T compared with C: adjusted OR =1.29, 95% CI =1.06-1.58, P =0.013). Furthermore, stratified analysis indicated that the rs11655237 T allele carriers were associated with increased neuroblastoma risk for patients with tumor originating from the adrenal gland (adjusted OR =1.51, 95% CI =1.06-2.14, P =0.021) and International Neuroblastoma Staging System (INSS) stage IV disease (adjusted OR =1.60, 95% CI =1.12-2.30, P =0.011). In conclusion, we verified that the LINC00673 rs11655237 C>T polymorphism might be associated with neuroblastoma susceptibility. Prospective studies with a large sample size and different ethnicities are needed to validate our findings. © 2018 The Author(s).

  1. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  2. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  3. Measurement of normal cervical spinal cord in metrizamide CT myelography

    International Nuclear Information System (INIS)

    Suzuki, Fumio; Koyama, Tsunemaro; Aii, Heihachirou

    1985-01-01

    The shape of the spinal cord is the most important factor in diagnosis of spinal disorders by metrizamide CT myelography (met. CT). Even in cases where the spinal cord looks normal in shape its size might be abnormal, for example in cases with spinal cord atrophy, syringomyelia, intramedullary tumor and several other conditions. In detecting the slightest abnormality in such cases, it is absolutely necessary to have in hand the knowledge of the nomal size of the spinal cord at each level. We measured, therefore, the sagittal and transverse diameters of the cervical spinal cord in 55 patients with no known lesions on met. CT (Fig. 1). Comparing our results with those by others, we found some differences as to the size of the spinal cord. We assume that these differences are due to the differences in resolution of the CT scanners used. The size of the spinal cord tends to measure larger with a CT scanner with high resolution than with others. Previous authors reported that the size of the spinal cord would vary by window center settings. Our experimental results indicate, however, that window center settings do not significantly affect the measurements. It is concluded that the normal values of the spinal cord dimensions at each level somewhat differ by CT equipments used. One should have normal values with one's own equipment in hand in order to take full advantage of this sophisticated diagnostic technique. (author)

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  6. Destination India: Investigating the impact of Goa's attributes on families' leisure travel experience

    OpenAIRE

    Ekiz, Erdogan H.; Khoo-Lattimore, Catheryn

    2014-01-01

    The recent discourse of tourism development among officials within the Government of India has included the state of Goa, mainly because it has consistently witnessed positive economic impacts from tourism. However, in view of competition from other destinations, Goan tourism planners will need to identify important attributes of Goa that will positively affect tourists' destination loyalty. This study examines the correlation between five attributes of Goa and tourists' loyalty to Goa. Famil...

  7. CT in the evaluation of patients on ECMO due to acute respiratory failure

    International Nuclear Information System (INIS)

    Lidegran, Marika; Jorulf, Haakan; Palmer, Kenneth; Linden, Viveka

    2002-01-01

    Heading AbstractBackground. In patients with acute severe respiratory failure (ARF) treated with extracorporeal membrane oxygenation (ECMO) the radiological evaluation has until now almost exclusively relied on bedside radiography and US. At St. Goeran/Karolinska ECMO centre CT has become a routine complement to bedside examinations.Objective. To review retrospectively the frequency, indications and findings on CT of patients with ARF on ECMO and to evaluate the risk of complications associated with transportation for CT examinations.Materials and methods. One hundred twelve neonates, children and adults were treated with ECMO from May 1994 to January 2001. Forty-six per cent of these patients had CT examinations on one or more occasions during ECMO, giving a total number of 238 examination sites on 104 occasions. All CT examinations were performed in the Paediatric Radiology Department and included a 10-min transport using a mobile ECMO system.Results. CT was more often performed in older patients and in patients with long ECMO runs. The main indications were suspected complications of ECMO and/or the underlying disease or a delay in clinical improvement. In 57% of the CT occasions, significant findings affecting treatment were revealed. There were no complications associated with the examinations or transport.Conclusions. CT is safe and useful in evaluation of patients with ARF during ECMO. (orig.)

  8. Dynamic CT findings of pulmonary hamartoma: A comparison with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Wanglae; Jeong, Yeon Joo; Lee, Chang Hun; Lee, Ji Won; Kim, Yeong Dae [Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Busan (Korea, Republic of); Kim, Kun Il [Dept. of Radiology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine and Medical Research Institute, Yangsan (Korea, Republic of)

    2013-12-15

    Describe the dynamic CT findings of pulmonary hamartoma and to compare these findings with histopathologic findings. he Institutional Review Board approved this retrospective study and the requirement for patient informed consent was waived. The hemodynamic CT features of 11 patients (M : F = 6 : 5; mean age, 53.6 years) with pathologically proven pulmonary hamartoma were evaluated. All 11 patients underwent enhanced dynamic CT using a helical technique. A series of images were obtained throughout each nodule with 2.5-mm collimation at 0, 30, 60, 90 and 120 seconds and at 4, 5 and 15 minutes after an intravenous injection of contrast medium. Extents and patterns of enhancement were correlated with histologic tumor components. ll 11 tumors showed persistent enhancement with variable degrees of net enhancement [mean tumor peak enhancement, 48.6 ± 19.0 Hounsfield unit (HU); mean tumor net enhancement, 31.9 ± 11.8 HU] and thick capsular and septal enhancement. Histologically, all 11 tumors were composed of mature cartilage and loose mesenchymal tissue. A significant positive correlation was found between the net enhancement values and loose connective tissue component percentages (r = 0.749, p = 0.008); further, a negative correlation was found between the net enhancement values and cartilaginous component percentages (r = -0.813, p = 0.002). n dynamic CT, hamartoma exhibited persistent enhancement without washout as well as thick capsular and septal enhancements. Net enhancement values were found to be positively correlated with the proportion of the loose connective tissue component. Thick capsular and septal enhancements were attributed histopathologically to loose connective tissue, separating tumors into cartilaginous lobules.

  9. Dynamic CT findings of pulmonary hamartoma: A comparison with histopathologic findings

    International Nuclear Information System (INIS)

    Cho, Wanglae; Jeong, Yeon Joo; Lee, Chang Hun; Lee, Ji Won; Kim, Yeong Dae; Kim, Kun Il

    2013-01-01

    Describe the dynamic CT findings of pulmonary hamartoma and to compare these findings with histopathologic findings. he Institutional Review Board approved this retrospective study and the requirement for patient informed consent was waived. The hemodynamic CT features of 11 patients (M : F = 6 : 5; mean age, 53.6 years) with pathologically proven pulmonary hamartoma were evaluated. All 11 patients underwent enhanced dynamic CT using a helical technique. A series of images were obtained throughout each nodule with 2.5-mm collimation at 0, 30, 60, 90 and 120 seconds and at 4, 5 and 15 minutes after an intravenous injection of contrast medium. Extents and patterns of enhancement were correlated with histologic tumor components. ll 11 tumors showed persistent enhancement with variable degrees of net enhancement [mean tumor peak enhancement, 48.6 ± 19.0 Hounsfield unit (HU); mean tumor net enhancement, 31.9 ± 11.8 HU] and thick capsular and septal enhancement. Histologically, all 11 tumors were composed of mature cartilage and loose mesenchymal tissue. A significant positive correlation was found between the net enhancement values and loose connective tissue component percentages (r = 0.749, p = 0.008); further, a negative correlation was found between the net enhancement values and cartilaginous component percentages (r = -0.813, p = 0.002). n dynamic CT, hamartoma exhibited persistent enhancement without washout as well as thick capsular and septal enhancements. Net enhancement values were found to be positively correlated with the proportion of the loose connective tissue component. Thick capsular and septal enhancements were attributed histopathologically to loose connective tissue, separating tumors into cartilaginous lobules.

  10. Impact factor of relationships between CT value and relative electron density for treatment planning system

    International Nuclear Information System (INIS)

    Feng Guosheng; Liang Yuan; Wu Danling; Hao Yanrong; Lu Heming; Chen Jiaxin; Liao Chaolong; Mo Ying; Huang Yihang

    2012-01-01

    Objective: To study the CT values of certain phantoms scanned by various CT scanners with dissimilar parameters. Methods: The CT values of tissue equivalent inserts was measured in the TM164 and CIRS-062 phantom scanned by TOSHIBA AQUILION TM , SIEMENS SOMATOM TM SENSATION TM 64 and SIEMENS SOMATOM TM SENSATION TM OPEN with different voltages,currents and slice thicknesses and then the corresponding CT-to-density curves was compared. Results: There are no significant differences of CT values with various currents and slice thicknesses and also for low atom number materials scanned by different scanners with various tube voltages. The CT values of high atom number materials have obvious differences scanned with tube voltage,the maximum is about 400 HU. There are also significant differences between CT-density curves of two phantoms in the range from soft tissues to dense bone, the maximum is up to 500 HU. Conclusions: CT-density curves were highly affected by materials of phantoms, scanners and tube voltages. It is necessary to measure the curve with a comfortable phantom and certain scanner to assure the accuracy for dose calculation for treatment planning system. (authors)

  11. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  12. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    International Nuclear Information System (INIS)

    Verhaart, René F.; Paulides, Margarethus M.; Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F.; Verduijn, Gerda M.; Lugt, Aad van der

    2014-01-01

    models based on CT (T max : 38.0 °C) and CT and MRI (T max : 38.1 °C) result in similar simulated temperatures, while CT and MRI db (T max : 38.5 °C) resulted in significantly higher temperatures. The SAR corresponding to these temperatures did not differ significantly. Conclusions: Although MR imaging reduces the interobserver variation in most tissues, it does not affect simulated local tissue temperatures. However, the improved soft-tissue contrast provided by MRI allows generating a detailed brain segmentation, which has a strong impact on the predicted local temperatures and hence may improve simulation guided hyperthermia

  13. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Verhaart, René F., E-mail: r.f.verhaart@erasmusmc.nl; Paulides, Margarethus M. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F. [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands); Verduijn, Gerda M. [Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Lugt, Aad van der [Department of Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands)

    2014-12-15

    ). Patient models based on CT (T{sub max}: 38.0 °C) and CT and MRI (T{sub max}: 38.1 °C) result in similar simulated temperatures, while CT and MRI{sub db} (T{sub max}: 38.5 °C) resulted in significantly higher temperatures. The SAR corresponding to these temperatures did not differ significantly. Conclusions: Although MR imaging reduces the interobserver variation in most tissues, it does not affect simulated local tissue temperatures. However, the improved soft-tissue contrast provided by MRI allows generating a detailed brain segmentation, which has a strong impact on the predicted local temperatures and hence may improve simulation guided hyperthermia.

  14. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: a comparison of CT and CT-MRI based tissue segmentation on simulated temperature.

    Science.gov (United States)

    Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van der Lugt, Aad; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M

    2014-12-01

    (Tmax: 38.1 °C) result in similar simulated temperatures, while CT and MRIdb (Tmax: 38.5 °C) resulted in significantly higher temperatures. The SAR corresponding to these temperatures did not differ significantly. Although MR imaging reduces the interobserver variation in most tissues, it does not affect simulated local tissue temperatures. However, the improved soft-tissue contrast provided by MRI allows generating a detailed brain segmentation, which has a strong impact on the predicted local temperatures and hence may improve simulation guided hyperthermia.

  15. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  16. Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring.

    Science.gov (United States)

    Sodickson, Aaron; Warden, Graham I; Farkas, Cameron E; Ikuta, Ichiro; Prevedello, Luciano M; Andriole, Katherine P; Khorasani, Ramin

    2012-08-01

    To develop and validate an informatics toolkit that extracts anatomy-specific computed tomography (CT) radiation exposure metrics (volume CT dose index and dose-length product) from existing digital image archives through optical character recognition of CT dose report screen captures (dose screens) combined with Digital Imaging and Communications in Medicine attributes. This institutional review board-approved HIPAA-compliant study was performed in a large urban health care delivery network. Data were drawn from a random sample of CT encounters that occurred between 2000 and 2010; images from these encounters were contained within the enterprise image archive, which encompassed images obtained at an adult academic tertiary referral hospital and its affiliated sites, including a cancer center, a community hospital, and outpatient imaging centers, as well as images imported from other facilities. Software was validated by using 150 randomly selected encounters for each major CT scanner manufacturer, with outcome measures of dose screen retrieval rate (proportion of correctly located dose screens) and anatomic assignment precision (proportion of extracted exposure data with correctly assigned anatomic region, such as head, chest, or abdomen and pelvis). The 95% binomial confidence intervals (CIs) were calculated for discrete proportions, and CIs were derived from the standard error of the mean for continuous variables. After validation, the informatics toolkit was used to populate an exposure repository from a cohort of 54 549 CT encounters; of which 29 948 had available dose screens. Validation yielded a dose screen retrieval rate of 99% (597 of 605 CT encounters; 95% CI: 98%, 100%) and an anatomic assignment precision of 94% (summed DLP fraction correct 563 in 600 CT encounters; 95% CI: 92%, 96%). Patient safety applications of the resulting data repository include benchmarking between institutions, CT protocol quality control and optimization, and cumulative

  17. Stigmatizing attitudes towards individuals with anorexia nervosa: an investigation of attribution theory.

    Science.gov (United States)

    Zwickert, Kristy; Rieger, Elizabeth

    2013-01-01

    Guided by Attribution Theory, this study assessed stigmatizing attitudes towards an individual with anorexia nervosa (AN) compared to obesity and skin cancer, and examined the extent to which manipulating a target individual's level of blameworthiness affects levels of stigmatizing attitudes. One hundred and thirty-five female undergraduate students were randomly assigned to one of three conditions. Before and after receiving blameworthy or non-blameworthy information relating to the target's condition, participants completed a series of self-report inventories measuring their emotional reactions, desire for social distance, and causal attributions regarding the target. Participants reported a significantly greater desire for social distance from the target with AN compared to targets with obesity or skin cancer, and yet (contrary to Attribution Theory) attributed less blame to the target with AN. There were significant increases in stigmatization towards targets described as blameworthy relative to targets described as non-blameworthy. The findings provide insight into the elevated levels of stigmatizing attitudes held towards individuals with AN, and the role of Attribution Theory in partially accounting for this stigma.

  18. 18F-FDG PET and PET/CT in Burkitt's lymphoma

    International Nuclear Information System (INIS)

    Karantanis, Dimitrios; Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P.; Georgiou, Evangelos; Johnston, Patrick B.; Wiseman, Gregory A.

    2010-01-01

    Objective: To explore the value of 18 F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  19. Survival or Mortality: Does Risk Attribute Framing Influence Decision-Making Behavior in a Discrete Choice Experiment?

    Science.gov (United States)

    Veldwijk, Jorien; Essers, Brigitte A B; Lambooij, Mattijs S; Dirksen, Carmen D; Smit, Henriette A; de Wit, G Ardine

    2016-01-01

    To test how attribute framing in a discrete choice experiment (DCE) affects respondents' decision-making behavior and their preferences. Two versions of a DCE questionnaire containing nine choice tasks were distributed among a representative sample of the Dutch population aged 55 to 65 years. The DCE consisted of four attributes related to the decision regarding participation in genetic screening for colorectal cancer (CRC). The risk attribute included was framed positively as the probability of surviving CRC and negatively as the probability of dying from CRC. Panel mixed-logit models were used to estimate the relative importance of the attributes. The data of the positively and negatively framed DCE were compared on the basis of direct attribute ranking, dominant decision-making behavior, preferences, and importance scores. The majority (56%) of the respondents ranked survival as the most important attribute in the positively framed DCE, whereas only a minority (8%) of the respondents ranked mortality as the most important attribute in the negatively framed DCE. Respondents made dominant choices based on survival significantly more often than based on mortality. The framing of the risk attribute significantly influenced all attribute-level estimates and resulted in different preference structures among respondents in the positively and negatively framed data set. Risk framing affects how respondents value the presented risk. Positive risk framing led to increased dominant decision-making behavior, whereas negative risk framing led to risk-seeking behavior. Attribute framing should have a prominent part in the expert and focus group interviews, and different types of framing should be used in the pilot version of DCEs as well as in actual DCEs to estimate the magnitude of the effect of choosing different types of framing. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  20. The Role of Affect in Rational (Attributional) Approaches to Human Motivation.

    Science.gov (United States)

    Weiner, Bernard

    1980-01-01

    Documents characteristics of emotions in relation to action and self-perception. Argues that taking affect into account yields a different interpretation of successful achievement-change programs. Also clarifies the differences between ability and effort as perceived causes of success and failure. (Author/GC)

  1. Bone SPECT/CT in the postoperative spine: a focus on spinal fusion

    Energy Technology Data Exchange (ETDEWEB)

    Al-Riyami, Khulood; Bomanji, Jamshed [University College London Hospitals, Institute of Nuclear Medicine, London (United Kingdom); Gnanasegaran, Gopinath [Royal Free Hospital, Department of Nuclear Medicine, London (United Kingdom); Wyngaert, Tim van den [Antwerp University Hospital, Department of Nuclear Medicine, Edegem (Belgium); University of Antwerp, Faculty of Medicine and Health Sciences, Wilrijk (Belgium)

    2017-11-15

    Low back pain is a global problem affecting one in 10 people. The management of low back pain varies from conservative to more invasive methods with a spectacular increase in the number of patients undergoing spinal fusion surgery during the last decade. Conventional radiological and radionuclide studies are often used in the assessment of persistent or recurring pain after spinal surgery with several advantages and limitations related to each technique. This article reviews the key contribution of integrated bone SPECT/CT in evaluating patients with persistent or recurring pain after spinal surgery, focusing on spinal fusion. Current literature supports the use of bone SPECT/CT as an adjunct imaging modality and problem-solving tool in evaluating patients with suspicion of pseudarthrosis, adjacent segment degeneration, and hardware failure. The role of bone SPECT/CT in post-operative orthopaedic scenarios is evolving, and this review highlights the need for further research on the role of bone SPECT/CT in these patients. (orig.)

  2. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  3. A keyword searchable attribute-based encryption scheme with attribute update for cloud storage.

    Science.gov (United States)

    Wang, Shangping; Ye, Jian; Zhang, Yaling

    2018-01-01

    Ciphertext-policy attribute-based encryption (CP-ABE) scheme is a new type of data encryption primitive, which is very suitable for data cloud storage for its fine-grained access control. Keyword-based searchable encryption scheme enables users to quickly find interesting data stored in the cloud server without revealing any information of the searched keywords. In this work, we provide a keyword searchable attribute-based encryption scheme with attribute update for cloud storage, which is a combination of attribute-based encryption scheme and keyword searchable encryption scheme. The new scheme supports the user's attribute update, especially in our new scheme when a user's attribute need to be updated, only the user's secret key related with the attribute need to be updated, while other user's secret key and the ciphertexts related with this attribute need not to be updated with the help of the cloud server. In addition, we outsource the operation with high computation cost to cloud server to reduce the user's computational burden. Moreover, our scheme is proven to be semantic security against chosen ciphertext-policy and chosen plaintext attack in the general bilinear group model. And our scheme is also proven to be semantic security against chosen keyword attack under bilinear Diffie-Hellman (BDH) assumption.

  4. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  5. Multidetector-row CT: economics and workflow

    International Nuclear Information System (INIS)

    Pottala, K.M.; Kalra, M.K.; Saini, S.; Ouellette, K.; Sahani, D.; Thrall, J.H.

    2005-01-01

    With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such ad technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow. (orig.)

  6. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization

    International Nuclear Information System (INIS)

    Lenoir, Laurence; Garin, Etienne; Edeline, Julien; Rolland, Yann; Pracht, Marc; Raoul, Jean-Luc; Ardisson, Valerie; Bourguet, Patrick; Clement, Bruno; Boucher, Eveline

    2012-01-01

    Identifying gastroduodenal uptake of 99m Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind. (orig.)

  7. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lenoir, Laurence; Garin, Etienne [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Edeline, Julien [University of Rennes 1, Rennes (France); Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Rolland, Yann [Comprehensive Cancer Institute Eugene Marquis, Department of Medical Imaging, CS 44229, Rennes (France); Pracht, Marc [Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Raoul, Jean-Luc [Comprehensive Cancer Institute Paoli Calmette, Department of Medical Oncology, Marseille (France); Ardisson, Valerie [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); Bourguet, Patrick [Comprehensive Cancer Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); Clement, Bruno [Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Boucher, Eveline [Liver Metabolisms and Cancer, INSERM, U-991, Rennes (France); Comprehensive Cancer Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France)

    2012-05-15

    Identifying gastroduodenal uptake of {sup 99m}Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind. (orig.)

  8. Analysis of patient CT dose data using virtualdose

    Science.gov (United States)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT

  9. Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

    Directory of Open Access Journals (Sweden)

    Atif N Khan

    2014-01-01

    Full Text Available Objectives: This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA following decennial screening guidelines. Material and Methods: Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from prior published literature for the 64 row CT scanner were compared with data from our study using 320 row detector CT scanner. Data from the 64 row and the 320 row detector CT scanners was used to determine lifetime attributable risks (LAR of cancer based on the biological effects of ionizing radiation (BEIR VII report. Results: The relative reduction of LAR (% for 50-, 60-, and 70-year-old patients undergoing scanning with the 320 row detector CT scanner was 30% lower for lung, and more than 50% lower for female breast when compared with results from 64 row detector CT scanner. The use of 320 row detector CT would result in a combined cumulative cancer incidence of less than 1/500 for breast in women and less than 1/1000 for lung in men; By comparison, this is much lower than other more common risk factors: 16-fold for lung cancer in persistent smokers, 2-fold for breast cancer with a first degree family member history of breast cancer, and 10-fold for thyroid cancer with a family member with thyroid cancer. Decennial screening would benefit at least 355,000 patients from sudden cardiac death each year, 94% of whom have significant coronary artery disease, with at least one stenosis >75%. LAR for thyroid cancer was negligible for both scanners. Conclusion: Lung and female breast LAR reductions with 320 row detector compared with 64 row detector CT are substantial, and the benefits would outweigh increased cancer risks with decennial screening in the age group of 50-70 years.

  10. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  14. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  15. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    International Nuclear Information System (INIS)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B.; Screaton, Nicholas J.

    2009-01-01

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  16. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  17. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  18. DIPNECH: when to suggest this diagnosis on CT

    International Nuclear Information System (INIS)

    Chassagnon, G.; Favelle, O.; Marchand-Adam, S.; De Muret, A.; Revel, M.P.

    2015-01-01

    Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia (DIPNECH) is an under-recognized disease characterized by proliferation of neuroendocrine cells in the bronchial wall. It is considered a pre-invasive lesion for lung carcinoid tumours and is found in 5.4% of patients undergoing surgical resection for lung carcinoid tumours. Other manifestations of DIPNECH include bronchial obstruction and formation of tumorlets. DIPNECH preferentially affects middle-aged women. Patients are either asymptomatic or present with long-standing dyspnoea due to obstructive syndrome that can be mistaken for asthma. At CT, mosaic attenuation with multiple small nodules is very suggestive of DIPNECH. The aim of this review is to describe DIPNECH-related CT features and correlate them with histology, in order to help radiologists suggest this diagnosis and distinguish DIPNECH from other causes of mosaic perfusion

  19. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  20. Cerebral lymphoma - CT and MRI diagnostic

    International Nuclear Information System (INIS)

    Popovska, T.; Yanakiev, A.; Zashev, I.

    2012-01-01

    Lymphoma (Hodgkin's and non-Hodgkin's) is a disease of the lymphatic system where the central neural system is affected in very rare cases. According to different authors the frequency of cases with lymphoma where the neural system is affected varies between 0, 2 % and 0, 5 %, and the primary cerebral lymphoma accounts for about 1-2% of ail brain neoplasms. The intracranial form of iymphoma is usually a late onset of the disease with serious and potentially fatal complications for the patient. These complications usually appear several years after diagnosing the disease, but the cerebral lymphoma may occur even in patients who are in remission which is the case with our patient. We present you a case with a 38 -year-old female, who was hospitalized in the Neuro ward with the following complaints -loss of speech for a few minutes, dizziness, weakness, tingling in her right leg as well as shuffling. This patient was diagnosed with histological B-cell non-Hodgkin's lymphoma 8 years ago. CT and MRI were carried out on that patient. Despite both clinical and radiographic suspicions for intracranial forms of lymphoma, the patient was still difficult to diagnose. A definitive diagnosis was given after a surgery and histological examination, i.e. non-Hodgkin's lymphoma - large B-cell lymphoma. This case is of interest because of its rare intracranial localization of the lymphoma. The knowledge of CT and MRI images of the intracranial form of lymphoma may help diagnosing, but images should be interpreted together with the clinical and paraclinical results Hodgkin's and non-Hodgkin's) is a disease of the lymphatic system where the central neural system is affected in very rare cases. According to different authors the frequency of cases with lymphoma where the neural system is affected varies between 0, 2 % and 0, 5 %, and the primary cerebral lymphoma accounts for about 1-2% of ail brain neoplasms. The intracranial form of iymphoma is usually a late onset of the disease

  1. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  2. Female patients dosimetry in brain exams with PET/CT scan for diagnosis of Mild Cognitive Impairment (MCI)

    International Nuclear Information System (INIS)

    Santana, P.C.; Mamede, M.; Carvalho, F.M.V.; Mourao, A.P.

    2013-01-01

    Dementia affects over 35 million people worldwide, with strong personal, social and financial impacts. Alzheimer's disease is the most common form of dementia, accounting for 60-70% of cases, affecting mostly females. Recent technological innovations, using methods of anatomical and functional neuroimaging, with particular emphasis on PET / CT (positron emission tomography with computed tomography associated), have shown excellent prospects for early diagnosis of Alzheimer's disease represented by Mild Cognitive Impairment (MCI). The use of PET / CT helps diagnosis, but the patients effective dose is higher and directly dependent on the radiopharmaceutical activity and the computed tomographic (CT) protocol used. The aim of this study was evaluated the organs absorbed doses and effective doses in 59 female patients undergoing the PET/CT diagnostic technique. For the measurements of radiation levels from the CT was used TLD100 (LiF:Mg, Ti) Rod detectors inserted in Alderson Randon ® anthropomorphic phantom, which simulates a female pattern, of 155 cm and weight 50 kg, subjected to the same clinical protocol of acquiring patients images. The effective dose resulting from the radiopharmaceutical injected activity was estimated by ICRP106 model using the weight of the patients undergoing to the procedure. The average effective dose due was (7.65 ± 2.22) mSv. The effective dose contribution to the brain and the thyroid due to CT were (2.21 ± 0.38) and (0.72 ± 0.14) mSv, respectively. The use of CT optimized protocols can assist in reducing the dose in this type of procedure. (author)

  3. Female patients dosimetry in brain exams with PET/CT scan for diagnosis of Mild Cognitive Impairment (MCI)

    Energy Technology Data Exchange (ETDEWEB)

    Santana, P.C.; Mamede, M.; Carvalho, F.M.V., E-mail: pridili@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Mourao, A.P., E-mail: apratabhz@gmail.com [Centro Federal de Educacao Tecnologica, Belo Horionte, MG (Brazil). Dept. de Engenharia Eletrica; Oliveira, P.M.C.; Silva, T.A. da, E-mail: pmco@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Dementia affects over 35 million people worldwide, with strong personal, social and financial impacts. Alzheimer's disease is the most common form of dementia, accounting for 60-70% of cases, affecting mostly females. Recent technological innovations, using methods of anatomical and functional neuroimaging, with particular emphasis on PET / CT (positron emission tomography with computed tomography associated), have shown excellent prospects for early diagnosis of Alzheimer's disease represented by Mild Cognitive Impairment (MCI). The use of PET / CT helps diagnosis, but the patients effective dose is higher and directly dependent on the radiopharmaceutical activity and the computed tomographic (CT) protocol used. The aim of this study was evaluated the organs absorbed doses and effective doses in 59 female patients undergoing the PET/CT diagnostic technique. For the measurements of radiation levels from the CT was used TLD100 (LiF:Mg, Ti) Rod detectors inserted in Alderson Randon ® anthropomorphic phantom, which simulates a female pattern, of 155 cm and weight 50 kg, subjected to the same clinical protocol of acquiring patients images. The effective dose resulting from the radiopharmaceutical injected activity was estimated by ICRP106 model using the weight of the patients undergoing to the procedure. The average effective dose due was (7.65 ± 2.22) mSv. The effective dose contribution to the brain and the thyroid due to CT were (2.21 ± 0.38) and (0.72 ± 0.14) mSv, respectively. The use of CT optimized protocols can assist in reducing the dose in this type of procedure. (author)

  4. Strictness Analysis for Attribute Grammars

    DEFF Research Database (Denmark)

    Rosendahl, Mads

    1992-01-01

    interpretation of attribute grammars. The framework is used to construct a strictness analysis for attribute grammars. Results of the analysis enable us to transform an attribute grammar such that attributes are evaluated during parsing, if possible. The analysis is proved correct by relating it to a fixpoint...... semantics for attribute grammars. An implementation of the analysis is discussed and some extensions to the analysis are mentioned....

  5. Public Response to a Near-Miss Nuclear Accident Scenario Varying in Causal Attributions and Outcome Uncertainty.

    Science.gov (United States)

    Cui, Jinshu; Rosoff, Heather; John, Richard S

    2018-05-01

    Many studies have investigated public reactions to nuclear accidents. However, few studies focused on more common events when a serious accident could have happened but did not. This study evaluated public response (emotional, cognitive, and behavioral) over three phases of a near-miss nuclear accident. Simulating a loss-of-coolant accident (LOCA) scenario, we manipulated (1) attribution for the initial cause of the incident (software failure vs. cyber terrorist attack vs. earthquake), (2) attribution for halting the incident (fail-safe system design vs. an intervention by an individual expert vs. a chance coincidence), and (3) level of uncertainty (certain vs. uncertain) about risk of a future radiation leak after the LOCA is halted. A total of 773 respondents were sampled using a 3 × 3 × 2 between-subjects design. Results from both MANCOVA and structural equation modeling (SEM) indicate that respondents experienced more negative affect, perceived more risk, and expressed more avoidance behavioral intention when the near-miss event was initiated by an external attributed source (e.g., earthquake) compared to an internally attributed source (e.g., software failure). Similarly, respondents also indicated greater negative affect, perceived risk, and avoidance behavioral intentions when the future impact of the near-miss incident on people and the environment remained uncertain. Results from SEM analyses also suggested that negative affect predicted risk perception, and both predicted avoidance behavior. Affect, risk perception, and avoidance behavior demonstrated high stability (i.e., reliability) from one phase to the next. © 2017 Society for Risk Analysis.

  6. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  7. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  8. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  9. Aspergillus infection of the respiratory tract after lung transplantation: chest radiographic and CT findings

    International Nuclear Information System (INIS)

    Diederich, S.; Scadeng, M.; Flower, C.D.R.; Dennis, C.; Stewart, S.

    1998-01-01

    The objective of our study was to assess radiographic and CT findings in lung transplant patients with evidence of Aspergillus colonization or infection of the airways and correlate the findings with clinical, laboratory, bronchoalveolar lavage, biopsy and autopsy findings. The records of 189 patients who had undergone lung transplantation were retrospectively reviewed for evidence of Aspergillus colonization or infection of the airways. Aspergillus was demonstrated by culture or microscopy of sputum or bronchoalveolar lavage fluid or histologically from lung biopsies or postmortem studies in 44 patients (23 %). Notes and radiographs were available for analysis in 30 patients. In 12 of the 30 patients (40 %) chest radiographs remained normal. In 11 of 18 patients with abnormal radiographs pulmonary abnormalities were attributed to invasive pulmonary aspergillosis (IPA) in the absence of other causes for pulmonary abnormalities (8 patients) or because of histological demonstration of IPA (3 patients). In these 11 patients initial radiographic abnormalities were focal areas of patchy consolidation (8 patients), ill-defined pulmonary nodules (2 patients) or a combination of both (1 patient). In some of the lesions cavitation was demonstrated subsequently. At CT a ''halo'' of decreased density was demonstrated in some of the nodules and lesion morphology and location were shown more precisely. Demonstration of Aspergillus from the respiratory tract after lung transplantation does not necessarily reflect IPA but may represent colonization of the airways or semi-invasive aspergillosis. The findings in patients with IPA did not differ from those described in the literature in other immunocompromised patients, suggesting that surgical disruption of lymphatic drainage and nervous supply or effects of preservation and transport of the transplant lung do not affect the radiographic appearances. (orig.)

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  13. The growth and photosynthesis of Typha in oil sands process affected material and water

    Energy Technology Data Exchange (ETDEWEB)

    Foote, L. [Alberta Univ., Edmonton, AB (Canada); Hornung, J. [Petro-Canada, Calgary, AB (Canada)

    2007-07-01

    Aquatic plants such as cattail contribute substantially to the energy flow in wetlands. Since Typha (cattail) plants acquire and cycle carbon and nutrients through wetlands, their growth and recycling of captured nutrients are an important part of natural, healthy wetland ecosystems. Cattail are pervasive and satisfy many of the criteria to be used as indicators of wetland integrity. This study investigated if cattail growth and carbon accrual were influenced by oil sands process materials (OSPM) such as consolidated tailings (CT). The purpose was to facilitate land reclamation initiatives by evaluating the impact that constituents of oil sands process material have on aquatic plant growth. The study was conducted at Suncor's experimental trenches. Six lined basins were used, of which 3 were filled with natural water and 3 were filled with trench water. Cattail were planted in different growth medium combinations, including CT over CT; soil over soil; soil over CT; and soil over sterilized sand. All leaf lengths and widths were measured along with the photosynthesis of the leaves and root and plant biomass at planting and after 2-years growth. A larger leaf area was observed under oil sands process influence, which may indicate increased carbon accrual above ground. Leaf area data suggested that CT affected plants are quite productive. The study also indicated that oil sands affected water may reduce plant fitness, and therefore could influence the overall oil sands reclamation timelines. Conversely, cattail grown in soil capped process affected material had a much larger leaf area compared to those grown in soil capped sand, most likely due to the higher levels of ammonia in process affected material.

  14. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  15. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  17. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  18. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  19. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  20. Diagnostic Accuracy of CT in Paediatric Intracranial Neoplastic Lesions - Radiologic and Pathologic Correlation

    International Nuclear Information System (INIS)

    Qureshi, A.

    2011-01-01

    The frequency of paediatric tumours in developing countries could be attributed to the increased percentage (39% of total population of children) in the overall population. Therefore, extensive researches should be under taken in the field of Paediatric Oncology in the third world. Objective: This study was conducted to determine the diagnostic accuracy of CT by comparing the pre-operative radiological findings of paediatric brain tumours with post-operative histopathological findings on the basis of characteristic radiological features of various tumours. Materials and Methods: This was a hospital based prospective, cross-sectional and descriptive study carried out in Radiology Dept, KEMU / Mayo Hospital, Lahore. Study was conducted over a period of 3 years from June 2005 till June 2008 and comprised of 100 cases of paediatric brain tumours up to 12 years of age. Cases were also collected from Mayo and Children Hospital, Lahore. Results: Topographically, supratentorial tumours were found more than infratentorial 55 : 45. Low grade were more common than high grade 73 : 27. The most common tumour was astrocytoma with 52 cases. Medulloblastoma ranked the second with 16 cases followed by craniopharyngioma with 12 cases. Conclusion: The diagnostic accuracy of CT scan was found to be 83% when correlated with histopathology. CT proved fairly accurate in detection of paediatric intracranial neoplastic lesions. As CT is relatively commonly available inexpensive modality than MRI so it can be used as non invasive imaging modality. (author)

  1. Exploring Attribution Theory and Bias

    Science.gov (United States)

    Robinson, Jessica A.

    2017-01-01

    Courses: This activity can be used in a wide range of classes, including interpersonal communication, introduction to communication, and small group communication. Objectives: After completing this activity, students should be able to: (1) define attribution theory, personality attribution, situational attribution, and attribution bias; (2)…

  2. Exploring Work-Related Causal Attributions of Common Mental Disorders.

    Science.gov (United States)

    Olsen, Ingrid Blø; Øverland, Simon; Reme, Silje Endresen; Løvvik, Camilla

    2015-09-01

    Common mental disorders (CMDs) are major causes of sickness absence and disability. Prevention requires knowledge of how individuals perceive causal mechanisms, and in this study we sought to examine work-related factors as causal attribution of CMDs. A trial sample of n = 1,193, recruited because they struggled with work participation due to CMDs, answered an open-ended questionnaire item about what they believed were the most important causes of their CMDs. The population included participants at risk of sickness absence, and participants with reduced work participation due to sickness absence, disability or unemployment. We used thematic content analysis and categorized responses from 487 participants who reported work-related factors as causal attributions of their CMDs. Gender differences in work-related causal attributions were also examined. The participants attributed their CMDs to the following work-related factors; work stress, leadership, reduced work participation, job dissatisfaction, work conflict, social work environment, job insecurity and change, workplace bullying, and physical strain. Women tended to attribute CMDs to social factors at work. Findings from this study suggest several work-related risk factors for CMDs. Both factors at the workplace, and reduced work participation, were perceived by study participants as contributing causes of CMDs. Thus, there is a need to promote work participation whilst at the same time targeting aversive workplace factors. Further, our findings indicate that work-related factors may affect women and men differently. This illustrates that the association between work participation and CMDs is complex, and needs to be explored further.

  3. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  4. Detection of breast abnormalities on enhanced chest CT: Correlation with breast composition on mammography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Mi; Kang, Hee; Shin, Young Gyung; Yun, Jong Hyouk; Oh, Kyung Seung [Dept. of Radiology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan (Korea, Republic of)

    2017-02-15

    To investigate the capability of enhanced chest computed tomography (CT) for detecting breast abnormalities and to assess the influence of breast composition on this detectability. From 2000 to 2013, 75 patients who underwent mammography, breast sonography, and enhanced chest CT within one month and had abnormalities on sonography were included. Detection rate of breast abnormality on enhanced chest CT was compared among 4 types of breast composition by the Breast Imaging Reporting and Data System. Contribution of breast composition, size and enhancement of target lesions to detectability of enhanced chest CT was assessed using logistic regression and chi-square test. Of the 75 target lesions, 34 (45.3%) were detected on enhanced chest CT, corresponding with those on breast sonography; there were no significantly different detection rates among the 4 types of breast composition (p = 0.078). Breast composition [odds ratio (OR) = 1.07, p = 0.206] and enhancement (OR = 21.49, p = 0.998) had no significant effect, but size (OR = 1.23, p = 0.004) was a significant contributing factor influencing the detectability of enhanced chest CT for breast lesions. About half of the cases (45.3%) demonstrated breast lesions on chest CT corresponding with target lesions on sonography. Breast composition defined on mammography did not affect the detectability of enhanced chest CT for breast lesions.

  5. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  6. Left Vocal Cord Paralysis Detected by PET/CT in a Case of Lung Cancer

    Directory of Open Access Journals (Sweden)

    Ali Ozan Oner

    2015-01-01

    Full Text Available We report a patient with lung cancer. The first PET/CT imaging revealed hypermetabolic mass in the left aortopulmonary region and hypermetabolic nodule in the anterior segment of the upper lobe of the left lung. After completing chemotherapy and radiotherapy against the primary mass in the left lung, the patient underwent a second PET/CT examination for evaluation of treatment response. This test demonstrated, compared with the first PET/CT, an increase in the size and metabolic activity of the primary mass in the left lung in addition to multiple, pathologic-sized, hypermetabolic metastatic lymph nodes as well as multiple metastatic sclerotic areas in bones. These findings were interpreted as progressive disease. In addition, an asymmetrical FDG uptake was noticed at the level of right vocal cord. During follow-up, a laryngoscopy was performed, which demonstrated left vocal cord paralysis with no apparent mass. Thus, we attributed the paralytic appearance of the left vocal cord to infiltration of the left recurrent laryngeal nerve by the primary mass located in the apical region of the left lung. In conclusion, the knowledge of this pitfall is important to avoid false-positive PET results.

  7. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  8. CT pelvimetry

    International Nuclear Information System (INIS)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J.

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique [fr

  9. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction

    International Nuclear Information System (INIS)

    Raissaki, Maria; Perisinakis, Kostas; Damilakis, John; Gourtsoyiannis, Nicholas

    2010-01-01

    CT scans of the brain, sinuses and petrous bones performed as the initial imaging test for a variety of indications have the potential to expose the eye-lens, considered among the most radiosensitive human tissues, to a radiation dose. There are several studies in adults discussing the reduction of orbital dose resulting from the use of commercially available bismuth-impregnated latex shields during CT examinations of the head. To evaluate bismuth shielding-induced artefacts and to provide suggestions for optimal eye-lens shielding in paediatric head CT. A bismuth shield was placed over the eyelids of 60 consecutive children undergoing head CT. Images were assessed for the presence and severity of artefacts with regard to eye-shield distance and shield wrinkling. An anthropomorphic paediatric phantom and thermoluminescence dosimeters (TLDs) were used to study the effect of eye lens-to-shield distance on shielding efficiency. Shields were tolerated by 56/60 children. Artefacts were absent in 45% of scans. Artefacts on orbits, not affecting and affecting orbit evaluation were noted in 39% and 14% of scans, respectively. Diagnostically insignificant artefacts on intracranial structures were noted in 1 case (2%) with shield misplacement. Mean eye-lens-to-shield distance was 8.8 mm in scans without artefacts, and 4.3 mm and 2.2 mm in scans with unimportant and diagnostically important artefacts, respectively. Artefacts occurred in 8 out of 9 cases with shield wrinkling. Dose reduction remained unchanged for different shield-to-eye distances. Bismuth shielding-related artefacts occurring in paediatric head CT are frequent, superficial and diagnostically insignificant when brain pathology is assessed. Shields should be placed 1 cm above the eyes when orbital pathology is addressed. Shield wrinkling should be avoided. (orig.)

  10. Relationships between cone beam CT value and physical density in image guided radiation therapy

    International Nuclear Information System (INIS)

    Jiang Xiaoqin; Bai Sen; Zhong Renming; Tang Zhiquan; Jiang Qinfeng; Li Tao

    2007-01-01

    Objective: To evaluate the main factors affecting the relationship between physical density and CT value in cone-beam computed tomography(CBCT) for imaging guided radiation therapy(IGRT) by comparing the CT value in the image from cone-beam scanner and from fan-beam (FBCT) scanner of a reference phantom. Methods: A taking-park reference phantom with a set of tissue equivalent inserts was scanned at different energies different fields of view (FOV) for IGRT-CBCT and FBCT. The CT value of every insert was measured and compared. Results: The position of inserts in phantom, the size of phantom, the FOV of scanner and different energies had more effect on the relationships between physical density and the CT value from IGRT-CBCT than those from the normal FBCT. The higher the energy was, the less effect of the position of inserts in phantom, the size of phantom and the FOV of scanner on CT value, and the poorer density contrast was observed. Conclusion: At present, the CT value of IGRT-CBCT is not in the true HU value since the manufacturer has not corrected its number. Therefore, we are not able to use the CT value of CBCT for dose calculation in TPS. (authors)

  11. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  13. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    International Nuclear Information System (INIS)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem; Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom

    2016-01-01

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season

  14. Adverse drug reactions to CT contrast media in south Korea: Incidence and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyung Soo; Jeon, Kyung Nyeo; Moon, Jin Il; Choi, Bo Hwa; Baek, Hye Jin; Cho, Soo Buem [Dept. of Radiology, Gyeongsang National University Changwon Hospital, Gyeongsang National University School of Medicine, Changwon (Korea, Republic of); Lee, Sang Min; Ha, Ji Young; Choi, Dae Seob; Cho, Jae Min; Na, Jae Beom [Dept. of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju (Korea, Republic of)

    2016-07-15

    To evaluate the incidence, severity, and risk factors of adverse drug reactions (ADR) to intravenous administration of nonionic iodinated contrast media in computed tomography (CT), and to determine the recurrence rate after premedication in patients with a previous history of ADR. We prospectively recorded all ADR to intravenous CT contrast media in 32313 consecutive outpatients (54572 cases) who underwent contrast enhanced CT examinations. Clinical report forms and electronic medical records were reviewed to search for the incidence of ADR, treatment, and clinical outcome of patients. The risk factors of ADR to CT contrast media (age, sex, history of previous ADR, season) were evaluated using statistical analysis. Of the 54572 cases, a total of 191 (0.35%) had adverse reactions. Of the 191 cases, 157 (82%) were categorized as mild reactions, 29 (15%) were moderate, and 5 (3%) were severe. A total of 165 (86.4%) cases had acute adverse reactions (which occurred within 1 hour after administration), while 26 (13.6%) had delayed adverse reactions (occurred 1 hour after the administration). The rate of ADR was significantly higher in females [relative risk (RR) = 2.05, 95% confidence interval (CI) 1.53-2.75], patients under the age of 60 years (RR = 1.45, 95% CI 1.07-1.98), patients with a history of previous ADR (RR = 6.51, 95% CI 3.13-13.57), and in the spring season (RR = 1.44, 95% CI 1.07-1.95). The recurrence rate after premedication in patients with previous ADR to CT contrast media was 3.2% (8/247). No deaths occurred that were attributed to the contrast media. The incidence of ADR to nonionic CT contrast media was 0.35%; most of which were mild reactions. Risk factors for ADR included female gender, an age of under 60 years, a history of previous ADR, and spring season.

  15. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    Science.gov (United States)

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children. PMID:29354007

  16. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  17. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  18. Smoking-Attributable Mortality, Morbidity, and Economic Costs (SAMMEC) - Smoking-Attributable Expenditures (SAE)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2005-2009. SAMMEC - Smoking-Attributable Mortality, Morbidity, and Economic Costs. Smoking-attributable expenditures (SAEs) are excess health care expenditures...

  19. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  20. Attribute framing affects the perceived fairness of health care allocation principles

    Directory of Open Access Journals (Sweden)

    Eyal Gamliel

    2010-02-01

    Full Text Available Health care resource allocation is a central moral issue in health policy, and opinions about it have been studied extensively. Allocation situations have typically been described and presented in a positive manner (i.e., who should receive medical aid. On the other hand, the negative valence allocation situation (i.e., who should not receive medical aid has been relatively neglected. This paper demonstrates how positive versus negative framing of the exact same health care resource allocation situation can affect the perceived fairness of allocation principles. Participants usually perceived non-egalitarian principles (i.e., need, equity and tenure to be fairer in positively framed situations (i.e., to deliver health care resources to certain patients than negatively framed situation (i.e., not to deliver health care resources to other patients. However, framing did not affect the perceived fairness of the equality principle (i.e., a random draw. The paper offers a theoretical explanation for the effect of framing on the perceived fairness of heath care resource allocation and discusses implications for both researchers and policy makers.

  1. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  2. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  3. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  4. X-ray CT high-density artefact suppression in the presence of bones

    Energy Technology Data Exchange (ETDEWEB)

    Wei Jikun [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Chen Laigao [BioImaging Center of Emphasis, Pfizer Global Research and Development, 2800 Plymouth RD, Ann Arbor, MI 48105 (United States); Sandison, George A [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Liang Yun [Department of Radiology, Indiana University Medical School, Indianapolis, IN 46202 (United States); Xu, Lisa X [School of Mechanical Engineering, 585 Purdue Mall, West Lafayette, IN 47907-2040 (United States)

    2004-12-21

    This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy)

  5. X-ray CT high-density artefact suppression in the presence of bones

    International Nuclear Information System (INIS)

    Wei Jikun; Chen Laigao; Sandison, George A; Liang Yun; Xu, Lisa X

    2004-01-01

    This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy)

  6. Isthmocervical labelling and SPECT/CT for optimized sentinel detection in endometrial cancer: technique, experience and results.

    Science.gov (United States)

    Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H

    2014-08-01

    We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), pnegative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT

    International Nuclear Information System (INIS)

    Barille, M.F.; Wu, Jim S.; McMahon, Colm J.

    2014-01-01

    Aim: To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. Materials and methods: The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Results: Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Conclusion: Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT

  8. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  9. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  10. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  16. Chronic tuberculous empyema: relationships between preoperative CT findings and postoperative improvement measured by pulmonary function testing

    International Nuclear Information System (INIS)

    Kim, D.J.; Im, J.-G.; Goo, J.M.; Lee, H.J.; You, S.Y.; Song, J.W.

    2005-01-01

    AIMS: To evaluate whether preoperative computed tomography (CT) findings correlate with postoperative improvements in forced vital capacity (FVC) and forced expiratory volume during 1 s (FEV1) in persons who have undergone unilateral decortication because of unilateral chronic tuberculous empyema. METHODS: A retrospective study was carried out of 67 individuals who had undergone decortication because of chronic tuberculous empyema between January 1996 and December 2000. Of these, 13 subjects who had had preoperative chest CT and preoperative and postoperative pulmonary function tests (PFTs) were included in the investigation. On preoperative CT, the degree of volume reduction of the affected side was compared with that of the contralateral normal lung. The relative volume of empyema was calculated by dividing the volume occupied by the empyema by the sum of the total volume of the ipsilateral lung and the empyema volume. The thicknesses of pleura and extrapleural fat in the involved hemithorax were measured by CT at their thickest points, and the degree of atelectasis adjacent to the empyema in the diseased lung was assessed and classified. These five CT parameters and the ages of the patients were compared with preoperative and postoperative FVC and FEV1 changes. RESULTS: A significant negative correlation was found between FVC changes and the relative volume of the affected lung (FVC: p=0.039, RS=-0.58). FVC and FEV1 were found to be significantly and positively correlated with the relative volume of the empyema (FVC: p=0.005, RS=0.72; FEV1: p=0.014, RS=0.66) and the degree of atelectasis (FVC: p=0.007, RS=0.71; FEV1: p=0.029, RS=0.60) by Spearman's nonparametric correlation test. Other CT parameters and the ages of the patients were not found to be correlated with PFT changes. CONCLUSION: The relative volume of the affected side, the relative volume of empyema and the degree of atelectasis can predict improvements in FVC and FEV1 after decortication in patients

  17. Correlation between the CT manifestations and post-operative survival time in patients with thymic epithelial tumor

    International Nuclear Information System (INIS)

    Chen Juan; Tan Ye; Wang Xiangyang; Du Jun; Pan Jishu; Wei Jiahu

    2011-01-01

    Objective: To describe the CT manifestations of thymic epithelial tumor and explore the correlation between CT findings and post-operative tumor-related survival time. Methods: Ninety-one patients who underwent CT scan before operation were reviewed retrospectively. All cases had operation and were classified according to the WHO classification. The size, contour, shape, density and enhancement of the tumors on CT were assessed. Presence of mediastinal lymphadenopathy, great vessel invasion, metastasis to the lung or plural, myasthenia gravis (MG) were also analyzed. The survival rate was obtained using, the Kaplan-Meier method. The Cox model was applied to determine the factors affecting the tumor-related survivals. Chi square test was used to analyze the relationship between CT findings and WHO classification. Results: Two patients were excluded because of dying of myocardial infarction and colon cancer. The total 5-year survival rate was 84.3% (n=75). Eighty-nine patients had total 91 tumors. Tumors with diameter larger than 5 cm, lobular contour, heterogenous density, and presence of great vessel invasion, mediastinal lymphadenopathy, and metastasis were adverse factors which could significantly affect the survival time. Five-year survival rates of these factors were 72.7%, 77.3%, 76.7%, 73.8%, 30.0%, and 68.8%, respectively. Presence of MG was a favorable factor which also significantly affected the survival time (P 0.05). The result of the Cox multivariate analysis was consistent with that of the Log-rank test. For different WHO classification, there were significant different among the size or contour of the tumors, presence of great vessel invasion, mediastinal lymphadenopathy, and metastasis (χ 2 value were 6.598, 5.737, 18.307, 8.465, and 15.608, respectively P<0.05). Conclusions: CT findings may be served as predictors of clinical prognosis of the thymic epithelial tumors. Adverse factors for survival time are the size of the tumors and presence of

  18. Smoking-Attributable Mortality, Morbidity, and Economic Costs (SAMMEC) - Smoking-Attributable Mortality (SAM)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2005-2009. SAMMEC - Smoking-Attributable Mortality, Morbidity, and Economic Costs. Smoking-attributable mortality (SAM) is the number of deaths caused by cigarette...

  19. Experimental validation of a rapid Monte Carlo based micro-CT simulator

    International Nuclear Information System (INIS)

    Colijn, A P; Zbijewski, W; Sasov, A; Beekman, F J

    2004-01-01

    We describe a newly developed, accelerated Monte Carlo simulator of a small animal micro-CT scanner. Transmission measurements using aluminium slabs are employed to estimate the spectrum of the x-ray source. The simulator incorporating this spectrum is validated with micro-CT scans of physical water phantoms of various diameters, some containing stainless steel and Teflon rods. Good agreement is found between simulated and real data: normalized error of simulated projections, as compared to the real ones, is typically smaller than 0.05. Also the reconstructions obtained from simulated and real data are found to be similar. Thereafter, effects of scatter are studied using a voxelized software phantom representing a rat body. It is shown that the scatter fraction can reach tens of per cents in specific areas of the body and therefore scatter can significantly affect quantitative accuracy in small animal CT imaging

  20. Assessing the Impact of (Overly Socially Desirable Brand Attributes in Choice Conjoint Tasks

    Directory of Open Access Journals (Sweden)

    André Carlos Martins Menck

    2014-03-01

    Full Text Available This research assesses the effects of corporate social responsibility on choice behavior. The construct social responsibility is highly socially desirable by definition. As a result, choice tasks in such setting may be biased by social desirability. This paper unveils a data treatment on choice conjoint tasks that sorts out the respondents who are likely to be mostly affected by social desirability. In this research a survey with choice conjoint tasks is used to evaluate interaction effects of corporate social involvement on functional attributes. Choice on four different product categories is assessed in a 215 within-subject design embedded in a 3x2x2 between-subject design. The main effects of corporate social involvement come out strong. The predicted interactions between social involvement and the functional attributes of the products seem to be affected by social desirability, leading to unclear results. The sub-samples resulting from the data manipulation, however, provide empirical support to the hypotheses on the interaction terms. This indicates the appropriateness of a model in which social involvement signals that the firm’s arguments on its products’ credence attributes are worth trusting. Nonetheless, the results with the full data prevent assertive conclusions.

  1. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  2. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  3. The preliminary study of CT cerebral perfusion imaging in transient ischemic attacks

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Du Xiangying

    2002-01-01

    Objective: To probe the application of CT cerebral perfusion imaging on transient ischemic attacks (TIA). Methods: Conventional CT and CT cerebral perfusion imaging were performed on 5 normal adults and 20 patients with clinically diagnosed TIA. After regular CT examination, dynamic scans of 40 seconds were performed on selected slice (usually on the basal ganglia slice), while 40 ml non-ionic contrast material were bolus injected through antecubital vein with. These dynamic images were processed with the 'Perfusion CT' software package on a PC based workstation. Cerebral blood flow (CBF) and time to peak (TP) enhancement were measured within specific regions of the brain on CT perfusion images. Quantitative analysis was performed for these images. Results: A gradient of perfusion between gray matter and white matter was showed on cT perfusion images in normal adults and TIA patients. CBF and TP for normal cortical and white matter were 378.2 ml·min -1 ·L -1 , 7.8 s and 112.5 ml·min -1 ·L -1 , 9.9 s, respectively. In 20 cases with TIA, persisting abnormal perfusion changes corresponding to clinical symptoms were found in 15 cases with prolonged TP. Other 5 cases showed normal results. TP of affected side (11.8 +- 4.4) s compared with that of the contralateral side (9.1 +- 3.1) s was significantly prolonged (t = 5.277, P -1 · -1 ] and contralateral side [(229.1 +- 41.4) ml·min -1 ·L -1 ]. Conclusion: Perfusion CT provides valuable hemodynamic information and shows the extent of perfusion disturbances for patients with TIA

  4. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.

    Science.gov (United States)

    Barille, M F; Wu, Jim S; McMahon, Colm J

    2014-03-01

    To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. CNS involvement in AIDS: spectrum of CT and MR findings

    International Nuclear Information System (INIS)

    Thurnher, M.M.; Thurnher, S.A.; Schindler, E.

    1997-01-01

    The brain may be affected by a variety of abnormalities in association with human immunodeficiency virus (HIV) infection. Knowledge of their existence and characteristic imaging features are important to radiologists for detection, diagnosis, and initiation of an appropriate treatment. Although there is a considerable overlap in the imaging characteristics of different entities, some findings are found to be very suggestive of a particular disease. The CT and MR imaging techniques are commonly used in the diagnosis of neurological disorders in acquired immunodeficiency syndrome (AIDS) patients, to verify treatment response and to guide brain biopsy. This review attempts to describe CT and MR features of infectious and malignant brain disorders in HIV-seropositive patients. (orig.). With 13 figs

  6. CT arteriography of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, K; Matsuura, K; Baba, H; Numaguchi, Y; Komaki, S [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-04-01

    The technique of CT arteriography was introduced, and CT images of the upper abdomen were explained. Very clear enhancement of parenchyma and vessels (especially portal vein) of the object organs could be obtained by CT arteriography of the upper abdomen, anatomical structures of organs were identified more easily by CT arteriography than by conventional CT, and the amount of information obtained was increased by using CT arteriography. However, the indication of CT arteriography must be limited, because of its complexity that CT arteriography is performed after angiography and involves the invasion of patients' bodies. As described in many reports, CT arteriography is useful for malignant tumors of the liver, and it is worthwhile, especially when surgery for hepatocellular carcinoma is considered. CT arteriography for organs except the liver has not been discussed sufficiently. Therefore, an application of this method for other organs must be decided after consideration of the balance of the amount of information obtained by CT arteriography with invasion to patients.

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  8. Aortitis with antiphospholipid antibodies: CT and MR findings

    International Nuclear Information System (INIS)

    Seror, O.; Dordea, M.; Ghenassia, C.; Coderc, E.; Sellier, N.; Fain, O.

    1998-01-01

    Two cases of aortitis associated with the presence of antiphospholipid antibodies (APAs) are reported. Only CT and MR imaging were able to show these unusual form of aortitis preferentially affecting the outer aortic tunics. We conclude that aortitis could be a new manifestation of primary antiphospholipid syndrome (APS) and the initial pathological process before the development of aortic thrombosis, reported as a classical complication of APS. (orig.) (orig.)

  9. CT AND MRI FEATURES OF CAROTID BODY PARAGANGLIOMAS IN 16 DOGS.

    Science.gov (United States)

    Mai, Wilfried; Seiler, Gabriela S; Lindl-Bylicki, Britany J; Zwingenberger, Allison L

    2015-01-01

    Carotid body tumors (paragangliomas) arise from chemoreceptors located at the carotid bifurcation. In imaging studies, this neoplasm may be confused with other neck neoplasms such as thyroid carcinoma. The purpose of this retrospective, cross-sectional study was to describe computed tomographic (CT) and magnetic resonance imaging (MRI) characteristics of confirmed carotid body tumors in a multi-institutional sample of dogs. A total of 16 dogs met inclusion criteria (14 examined using CT and two with MRI). The most common reason for imaging was a palpable cervical mass or respiratory signs (i.e., dyspnea or increased respiratory noises). The most commonly affected breed was Boston terrier (n = 5). Dogs were predominantly male castrated (n = 10) and the median age was 9 years [range 3-14.5]. Most tumors appeared as a large mass centered at the carotid bifurcation, with poor margination in six dogs and discrete margins in ten dogs. Masses were iso- to hypoattenuating to adjacent muscles in CT images and hyperintense to muscles in T1- and T2-weighted MRI. For both CT and MRI, masses typically showed strong and heterogeneous contrast enhancement. There was invasion into the adjacent structures in 9/16 dogs. In six of these nine dogs, the basilar portion of the skull was affected. The external carotid artery was entrapped in seven dogs. There was invasion into the internal jugular vein in three dogs, and into the external jugular, maxillary, and linguo-facial veins in one dog. Imaging characteristics helped explain some clinical presentations such as breathing difficulties, Horner's syndrome, head tilt, or facial nerve paralysis. © 2015 American College of Veterinary Radiology.

  10. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM)

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M.; Kersting, S.; Putz, R.; Mueller-Gerbl, M.

    2003-01-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p [de

  11. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  12. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  13. Multiplanar CT assessment of femoral head displacement in slipped capital femoral epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Dwek, Jerry R. [Rady Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Hosalkar, Harish S. [Center for Hip Preservation, Department of Orthopedic Surgery, TriCity Medical Center, Oceanside, CA (United States)

    2013-12-15

    With recent changing approaches to the management of slipped capital femoral epiphysis (SCFE), the accurate radiographic assessment of maximum extent of displacement is crucial for planning surgical treatment. To determine what plane best represents the maximum SCFE displacement as quantified by the head-neck angle difference (HNAD), whether HNAD can quantitatively differentiate the SCFE cohort from the normal cohort, based on CT, and how Southwick slip angle (SSA) compares to HNAD. We reviewed 19 children with SCFE (23 affected hips) with preoperative CT scans and 27 age- and sex-matched children undergoing abdominal CT for non-orthopedic problems. Head-neck angle (HNA), the angle between the femoral epiphysis and the neck axis, was measured in three planes on each hip and the HNAD (affected - unaffected hip) was determined. SSA was measured on radiographs. The coronal HNAD (mean 8.7 ) was less than both the axial-oblique (mean 30.7 ) and sagittal (mean 37.4 ) HNADs, which were also greater than the HNADs of the normal cohort. Grouping HNAD measurements by SSA severity classification did not consistently distinguish between SCFE severity levels. Axial-oblique and sagittal planes best represent the maximum SCFE displacement while biplanar radiograph may underestimate the extent of the displacement, thereby potentially altering the management between in situ pinning and capital realignment. (orig.)

  14. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  15. CT of jejunal diverticulitis: imaging findings, differential diagnosis, and clinical management

    International Nuclear Information System (INIS)

    Macari, M.; Faust, M.; Liang, H.; Pachter, H.L.

    2007-01-01

    Aim: To describe the imaging findings of jejunal diverticulitis as depicted at contrast-enhanced computed tomography (CT) and review the differential diagnosis and clinical management. Materials and Methods: CT and pathology databases were searched for the diagnosis of jejunal diverticulitis. Three cases were identified and the imaging and clinical findings correlated. Results: Jejunal diverticulitis presents as a focal inflammatory mass involving the proximal small bowel. A trial of medical management with antibiotics may be attempted. Surgical resection may be required if medical management is unsuccessful. Conclusion: The imaging findings at MDCT may allow a specific diagnosis of jejunal diverticulitis to be considered and may affect the clinical management of the patient

  16. Headache Attributed to Craniocervical Dystonia - A Little Known Headache.

    Science.gov (United States)

    Bezerra, Marcos Eugenio Ramalho; Rocha-Filho, Pedro Augusto Sampaio

    2017-02-01

    Craniocervical dystonia is a focal or segmental dystonia in its distribution, classically known as spasmodic torticollis when in its pure cervical presentation. Although craniocervical dystonia has been recognized as a possible cause of headache since the publication of the second version of International Classification of Headache Disorders, there are few studies about this entity. This was a narrative review. Craniocervical dystonia was associated with muscle pain in 67-89% of the cases. Headaches of any kind affected approximately 60% of patients with craniocervical dystonia, and were located mainly in the occipital and cervical regions. Headache attributed to craniocervical dystonia specifically was rarely found, and it was described in only one patient out of 80 in one study. Treatment with botulinum neurotoxin is considered to be the first-line treatment for focal dystonias, including craniocervical dystonia, and besides reducing clinical severity, impairment, and pain scores among the patients with craniocervical dystonia, there were also descriptions of improvements in headaches attributed to craniocervical dystonia and other headaches associated with this dystonia. Headache attributed to craniocervical dystonia has been poorly studied. There is a need for more studies to evaluate its characteristics and treatment. © 2016 American Headache Society.

  17. Dosimetry estimation of SPECT/CT for iodine 123-labeled metaiodobenzylguanidine in children

    Directory of Open Access Journals (Sweden)

    Aida Mhiri

    2015-09-01

    Full Text Available Purpose: To evaluate the additional radiation exposure in terms of effective dose incurred by patients in the CT (computed tomography portion of 123I-MIBG (123II-metaiodobenzylguanidine study with SPECT/CT (Single photon emission computed tomography associated to computed tomography in some pediatric patients of our department. Methods: Data from 123II-MIBG scans comprising 50 children were presented in this study. The contribution of total effective dose imparted by the nuclear tracer and patient's age was calculated. Effective dose from the CT portion of the examination is also estimated.SPECT acquisitions were performed with a dual-headed SPECT unit with an integrated 2-slice CT scanner (Symbia T E-Cam, Siemens Medical Systems, Erlangen, Germany. The CT acquisition were performed using a tube current modulation system (Care Dose 4D. Parameters used were: tube current of 30 - 60 mAs, slice thickness of 3-5 mm, and tube voltage of 110 kV. Results: Our results show that SPECT dosimetry depends on administered activity and patient’s age and weight. For CT scan, effective dose is affected by tube current (mA, tube potential (kVp, rotation speed, pitch, slice thickness, patient mass, and the exact volume of the patient that is being imaged. Conclusion: For children, 123II-MIBG study with SPECT/CT should be performed using the lowest available voltage and current. A sensible choice of these two parameters used can significantly reduce radiation dose, without any compromise in the quality of the diagnostic information.

  18. SPECT/CT in gingival squamous cell carcinoma

    International Nuclear Information System (INIS)

    Nikolova, R.; Hadzhiyska, V.; Petrov, T.

    2015-01-01

    Gingival squamous cell carcinoma have a relatively poor prognosis and large differential diagnosis (periodontitis, osteomyelitis, etc.), therefore, it is usually diagnosed at a late stage. Hematogenous dissemination occurs in only about 10% of cases, including lung (66%), bone (22%), liver (10%), skin, bone marrow and mediastinum. Bone metastases are very rare compared to other malignancies, most commonly affect the axial skeleton (spine, pelvis, ribs and lumbar spine). In our case, we presented a patient with gingival squamous cell carcinoma and bone metastasis in the forearm detected with Whole Body Bone Scintigraphy (WBS), combined with Single Photon Emission Tomography /Computed Tomography (SPECT /CT). The obtained data suggest that the single use of WBS was not informative enough for making the final diagnosis, but the result of combined functional-morphological approach was the most pathognomonic. Thus, with single study can be obtained a complex information, which leads to a fast therapeutic decision. Key words: SPECT/CT. GINGiVAL. SQUAMOUS CELL CARCINOMA

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  2. Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction

    Science.gov (United States)

    Niu, Shanzhou; Yu, Gaohang; Ma, Jianhua; Wang, Jing

    2018-02-01

    Spectral computed tomography (CT) has been a promising technique in research and clinics because of its ability to produce improved energy resolution images with narrow energy bins. However, the narrow energy bin image is often affected by serious quantum noise because of the limited number of photons used in the corresponding energy bin. To address this problem, we present an iterative reconstruction method for spectral CT using nonlocal low-rank and sparse matrix decomposition (NLSMD), which exploits the self-similarity of patches that are collected in multi-energy images. Specifically, each set of patches can be decomposed into a low-rank component and a sparse component, and the low-rank component represents the stationary background over different energy bins, while the sparse component represents the rest of the different spectral features in individual energy bins. Subsequently, an effective alternating optimization algorithm was developed to minimize the associated objective function. To validate and evaluate the NLSMD method, qualitative and quantitative studies were conducted by using simulated and real spectral CT data. Experimental results show that the NLSMD method improves spectral CT images in terms of noise reduction, artifact suppression and resolution preservation.

  3. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  4. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  5. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  6. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  7. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  8. Thrombophlebitis of the internal jugular vein (Lemierre syndrome) - Clinical and CT findings

    International Nuclear Information System (INIS)

    Kim, Bo Yeon; Yoon, Dae Young; Lim, Kyoung Ja; Seo, Young Lan; Yun, Eun Joo; Choi, Chul Soon; Bae, Sang Hoon; Kim, Hyeong Chul; Kim, Eun Soo; Baek, Sora

    2013-01-01

    Background: Thrombophlebitis of the internal jugular vein (IJV) secondary to neck infection (so-called Lemierre syndrome) is a rare disease. Purpose: To evaluate the clinical and CT findings in patients with thrombophlebitis of the IJV. Material and Methods: The clinical and contrast-enhanced neck CT findings were retrospective analyzed in 10 patients (eight men, two women; mean age, 62.9±8.3 years) with thrombophlebitis of the IJV. Results: Five patients (50%) had complications, including pneumonia (n = 3), neck abscess (n = 1), and thrombophlebitis of cerebral venous sinus (n = 1). All patients, except two who were lost to follow-up, had improved after antibiotics and anticoagulation therapy. Nine (90%) patients had underlying infectious processes in the neck. Contrast-enhanced neck CT of 12 IJVs (five right, three left, and two bilateral) affected by thrombophlebitis demonstrated > 5 cm in length (n = 8, 67%), ovoid shape (n = 7, 58%), complete occlusion of the lumen (n = 10, 83%), circumferential (n = 11, 92%), smooth (n = 8, 67%), and thick (=4 mm) (n = 8, 67%) rim enhancement, and adjacent soft tissue swelling (n = 11, 92%). Conclusion: Contrast-enhanced CT is useful in the diagnosis of thrombophlebitis of the IJV; characteristic CT findings of this unusual entity may be the main clue to the correct diagnosis

  9. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  10. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  11. [Asu(1,7)E-CT, an analog of eel calcitonin. A comparative study in man with reference to other synthetic calcitonins].

    Science.gov (United States)

    Caniggia, A; Nuti, R; Vattimo, A; Galli, M; Turchetti, V; Franci, B; Martorelli, T; Righi, G

    1983-04-28

    (Asu) E-CT is a deaminodicarba-analog of the synthetic eel-calcitonin (E-CT) that shows specific activity and the potency reasonably high in comparison with that of the most potent natural hormone. The structure of its molecule indicates that the disulphide bond in calcitonins is not essential for the biological activity but only for the maintenance of the specific conformation by forming an intramolecular bridge. The instability of calcitonins should mainly be attributed to the presence of the disulfide bond and (Asu)E-CT proved to be more stable "in vitro" than native calcitonins. The more prolonged hypocalcemic effect of E-CT and its aminosuberic analog (Asu)E-CT has been accounted for to a greater stability of and persistence at the receptor site. (Asu) E-CT has been largely studied in Japan on experimental animals and successfully used in the treatment of hypercalcemia in man. On the contrary investigations on human administration of this analog are very scarce. The present paper reports studies carried out in normal subjects and Paget's disease patients to investigate the effects of (Asu)E-CT in man in comparison with the effects of synthetic human calcitonin (H-CT) and synthetic salmon calcitonin (S-CT). Two different experimental procedures have been used: 1) rapid intravenous injection of (Asu)E-CT (80 MRC. U.) or respectively of H-CT and S-CT (100 MRC. U.) in 15 subjects (7 normals and 8 with Paget's disease); 2) slow 7 days continuous subcutaneous infusion of similar daily amounts of (Asu)E-CT, H-CT and S-CT administered by a microjet pump device in 21 subjects (7 normals and 14 with Paget's disease). The intravenous administration of (Asu)E-CT induced a rapid and persistent decrease in total plasma calcium, ionized calcium and plasma phosphate that was more evident in Paget's disease patients than in normal subjects. No clearly cut differences have been observed with the hypocalcemic and hypophosphatemic effect of H-CT and S-CT administered

  12. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    Science.gov (United States)

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  13. Why did they do it? How customers’ self-service technology introduction attributions affect the customer-provider relationship

    NARCIS (Netherlands)

    Nijssen, E.J.; Schepers, J.J.L.; Belanche, D.

    2016-01-01

    Purpose – Customers often think that innovations, such as self-service technologies (SSTs), are introduced by service providers to cut costs rather than extend customer service levels. The purpose of this paper is to investigate how customers use such attributions to adjust their perceptions of

  14. Televised relational and physical aggression and children's hostile intent attributions.

    Science.gov (United States)

    Martins, Nicole

    2013-12-01

    An experiment was conducted with 150 children (mean age=10.1years) in third to fifth grades to test whether exposure to different forms of aggression in the media affected hostile attributional biases in response to different forms of provocation scenarios. Children were randomly assigned to watch a clip containing physical aggression, relational aggression, or no aggression. After exposure, children were asked to respond to a series of written provocation scenarios where a character caused some form of harm (instrumental or relational) to a target person, but the intent of the provocateur was ambiguous. Results revealed that exposure to relationally aggressive portrayals resulted in a hostile attributional bias in response to relational scenarios, whereas exposure to portrayals of physical aggression was associated with a hostile attributional bias in response to instrumental scenarios. Moreover, these biases were shown to be specific to the exposure condition (physical or relational) and not simply associated with exposure to aggression in general. The findings are discussed in terms of the general aggression model and children's social information processing. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Low-dose quantitative phase contrast medical CT

    Science.gov (United States)

    Mittone, A.; Bravin, A.; Coan, P.

    2018-02-01

    X-ray computed tomography (CT) is a powerful and routinely used clinical diagnostic technique, which is well tolerated by patients, and which provides high-resolution images and volumetric information about the body. However, two important limitations still affect this examination procedure: (1) its low sensitivity with respect to soft tissues, and (2) the hazards associated with x-ray exposure. Conventional radiology is based on the detection of the different photon absorption properties that characterize biological tissues, and thus the obtainable image contrast from soft and/or similar tissues is intrinsically limited. In this scenario, x-ray phase contrast imaging (XPCI) has been extensively tested and proven to overcome some of the main issues surrounding standard x-ray imaging. In addition to the absorption signal, XPCI relies on detecting the phase shifts induced by an object. Interestingly, as the order of magnitude of the phase contrast is higher than that of absorption, XPCI can, in principle, offer higher sensitivity at lower radiation doses. However, other technical aspects may counterbalance this gain, and an optimized setup and image processing solutions need to be implemented. The work presented here describes the strategies and developments we have realized, with the aim of controlling the radiation dose for the highly sensitive and quantitative XPCI-CT. Different algorithms for the phase retrieval and CT reconstruction of the XPCI data are presented. The CT algorithms we have implemented, namely the equally sloped tomography and the dictionary learning method, allow the image quality to be preserved while reducing the number of angular projections required by a factor of five. The results applied to breast imaging report accurate reconstructions at clinically compatible doses of the 3D distribution of the refractive properties of full human organs obtained by using three different phase retrieval methods. The described methodologies and the

  16. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  17. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  18. Attribution style, theory and empirical findings

    OpenAIRE

    Krohn, Charlotte

    2017-01-01

    Master i læring i komplekse systemer Attribution theory is a long-standing and widely discussed theory that addresses individuals’ explanation of causes of events. People attribute events of success and failure individually. Previous studies indicate that performance in sporting events may be improved by changing individuals’ attribution style. Article one describes attribution and attribution theory as state of the art. The article addresses the most important findings within attribution ...

  19. Crura sign: differentiation between traumatic rupture of the diaphragm and nontraumatic diaphragmatic elevation on CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Han, Hae Ja; Kim, Wang Jung; Youk, Yong Soo; Han, Gi Seok; Cha, Sang Hoon; Park, Kil Sun; Kim, Dae Young

    1997-01-01

    To evaluate whether in patients with diffuse evaluation of a hemidiaphragm on chest radiographs, the apparence of the crura on CT might be helpful in differentiating between traumatic rupture of the diaphragm (TRD) and nontraumatic causes such as diaphragmatic palsy or diffuse diaphragmatic eventration. Among patients with diffuse elevations of a hemidiaphragm on chest radiograph, 27 who had patients undergone CT scans were retrospectively reviewed. Twelve patients had surgically proven TRD, and 15 had nontraumatic elevation of a hemidiaphragm such as diaphragmatic palsy or diffuse diaphragmatic eventration. Under the hypothesis that the affected crus is markedly thinner than the normal side in nontraumatic elevation but is normal in TRD ('crura sign', we optically assessed without measurement the thickness of both crura. In all patients with TRD, the thickness of the affected crus was similar to that of the contralateral side. In all patients with nontraumatic causes, however, the crus of the elevated hemidiaphragm was markedly thinner than that of the normal side. The 'crura sign' may be useful additional CT finding of traumatic rupture the diaphragm

  20. Clinical utility of FDG PET/CT in acute complicated pyelonephritis - results from an observational study

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Hsing [Mackay Memorial Hospital at Taipei, Department of Nuclear Medicine, Taipei (China); Tseng, Jing-Ren; Yen, Tzu-Chen [Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan (China); Lee, Ming-Hsun [Chang Gung Memorial Hospital at Linkou, Division of Infectious Diseases, Department of Internal Medicine, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou, Biostatistics Unit, Clinical Trial Center, Taoyuan (China)

    2018-03-15

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of {sup 18}F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course. (orig.)

  1. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  2. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  3. CT findings of leg muscles in the hemiplegics due to cerebrovascular accidents. Correlation to disuse atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Odajima, Natsu; Ishiai, Sumio; Okiyama, Ryouichi; Furukawa, Tetsuo; Tsukagoshi, Hiroshi

    1987-09-01

    Muscle wastings in hemiplegics due to cerebrovascular accidents were studied with CT scanning in the mid-portion of the thigh and largest-diameter section of the calf bilaterally. Muscle size and average CT density of muscle were measured. The 80 patients were classified into one of the following three stages of disability, i.e. stage 1, severely disabled (wheel-chair-bound but capable of self care (20 patients)); stage 2, moderately disabled (poorly ambulatory (41 patients)); and stage 3, mildly disabled (well ambulatory (19 patients)). Muscle cross-sectional area and CT density in both legs of non-ambulatory patients were smaller and lower than those of other groups. The atrophic change was marked in the affected side, but it was also noticeable in the non-affected side. Gracilis muscle was relatively well spared in all 3 stages. These CT findings of hemiplegics were similar to those of disuse atropy in patients with knee or hip joint lesions. Atrophy was seen first in the quadriceps in thigh and flexor muscle group in calf. These findings were similar to the systemic myogenic or neurogenic atrophies. Although gracilis and sartorius muscles were spared in these systemic deseases, only gracilis muscle was spared in hemiplegics and in patients with disuse atrophy. The ratios of the size of quadriceps, adductor group and sartorius muscle of thigh in affected side to that of non-affected side were smaller in more severely disabled group. Those of the other muscles showed no differences among each stages. In stage 3, there was significant negative correlation between the ratio of quadriceps muscle and periods from the attack. There was no relationship between the severity of the muscle atrophy and parietal lobe lesion. The atrophy is considered to be the result of disuse from immobilization.

  4. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  5. Effects of sparse sampling schemes on image quality in low-dose CT

    International Nuclear Information System (INIS)

    Abbas, Sajid; Lee, Taewon; Cho, Seungryong; Shin, Sukyoung; Lee, Rena

    2013-01-01

    Purpose: Various scanning methods and image reconstruction algorithms are actively investigated for low-dose computed tomography (CT) that can potentially reduce a health-risk related to radiation dose. Particularly, compressive-sensing (CS) based algorithms have been successfully developed for reconstructing images from sparsely sampled data. Although these algorithms have shown promises in low-dose CT, it has not been studied how sparse sampling schemes affect image quality in CS-based image reconstruction. In this work, the authors present several sparse-sampling schemes for low-dose CT, quantitatively analyze their data property, and compare effects of the sampling schemes on the image quality.Methods: Data properties of several sampling schemes are analyzed with respect to the CS-based image reconstruction using two measures: sampling density and data incoherence. The authors present five different sparse sampling schemes, and simulated those schemes to achieve a targeted dose reduction. Dose reduction factors of about 75% and 87.5%, compared to a conventional scan, were tested. A fully sampled circular cone-beam CT data set was used as a reference, and sparse sampling has been realized numerically based on the CBCT data.Results: It is found that both sampling density and data incoherence affect the image quality in the CS-based reconstruction. Among the sampling schemes the authors investigated, the sparse-view, many-view undersampling (MVUS)-fine, and MVUS-moving cases have shown promising results. These sampling schemes produced images with similar image quality compared to the reference image and their structure similarity index values were higher than 0.92 in the mouse head scan with 75% dose reduction.Conclusions: The authors found that in CS-based image reconstructions both sampling density and data incoherence affect the image quality, and suggest that a sampling scheme should be devised and optimized by use of these indicators. With this strategic

  6. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  7. Spinal CT-guided injections. Clinical applications-limitations

    International Nuclear Information System (INIS)

    Stamatakis, V.; Vlachou, I.; Petrocheilou, G.; Safarika, V.; Geroukis, I.; Petinelli, A.; Stathopoulou, S.; Kokkinis, C.

    2012-01-01

    Full text: Introduction: Chronic spinal pain is an important health issue with serious social and financial consequences. Thus, application of minimal invasive procedures is a popular technique for immediate relief of pain. Objectives and tasks: Our purpose is to present CT guided intraspinal injection of pharmaceutical agents for the relief of persistent pain. Material and methods: Chronic localized or radicular spinal pain may be treated safely and efficiently with injection of various pharmaceutical agents (local anesthetic, opioid analgesic and steroids or combination of these). The possible sites of infiltration include: a) intervertebral joints (facets), b) sacroiliac joints, c)perineural infiltration of the affected nerve roots and d) the epidural space. We will mention the patients choice criteria (combination of clinical symptoms and specific pain evaluation questionnaire) as they are reported in the international bibliography. Finally, we will discuss the repeatability criteria of the method as well as its limitations. Results: CT-guided pharmaceutical agents injection for the relief of persistent spinal pain have an advantage against other methods because of the precision and safety that they offer to the localization and diagnosis of the pain cause. Conclusion: Small complications percentage and satisfactory results have made CT-guided spinal injections a popular technique for chronic back pain relief. In order to apply these techniques the good knowledge of the method, its possibilities and limitations is necessary

  8. Dose reduction using bismuth shielding during paediatric CT examinations in Slovakia

    International Nuclear Information System (INIS)

    Gbelcova, L.; Nikodemova, D.; Horvathova, M.

    2011-01-01

    Considering the massive increase of computer tomography (CT) examinations in Slovakia during the last 10 y, it can be expected that a higher radiation load may be observed in the Slovak population. Since child population is more sensitive to radiation than adult population, a monitoring has started to see how high the radiation dose is for paediatric patients during CT examinations in chosen departments in Slovakia. The CT examination of the head is one of the most frequently done examinations in Slovakian departments and that is why measurements were done to clarify how usage of bismuth shields for eyes and thyroid can affect the eye and thyroid doses. For simulation, 215 thermoluminescent dosimeters were exposed on anthropomorphic phantom of a child with and without usage of bismuth shields. The result was that only two of the three chosen departments confirmed a reduction. On the other hand, one of the departments confirmed that the reduction can be up to 56-65 %, which is significant. (authors)

  9. Aortitis with antiphospholipid antibodies: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Seror, O.; Dordea, M.; Ghenassia, C.; Coderc, E.; Sellier, N. [Department of Radiology, Centre Hospitalo-Universitaire Paris XIII, Bondy (France); Fain, O. [Department of Medicine, Centre Hospitalo-Universitaire Paris XIII, Bondy (France)

    1998-10-01

    Two cases of aortitis associated with the presence of antiphospholipid antibodies (APAs) are reported. Only CT and MR imaging were able to show these unusual form of aortitis preferentially affecting the outer aortic tunics. We conclude that aortitis could be a new manifestation of primary antiphospholipid syndrome (APS) and the initial pathological process before the development of aortic thrombosis, reported as a classical complication of APS. (orig.) (orig.) With 2 figs., 6 refs.

  10. Biogeochemical Attributes That Affect the Fate and Transport of Military Relevant Contaminants Under Freeze-thaw Conditions

    Science.gov (United States)

    LeMonte, J.; Price, C. L.; Seiter, J.; Crocker, F. H.; Douglas, T.; Chappell, M. A.

    2017-12-01

    The roles and missions that the U.S. Department of Defense (DoD) undertakes in the Arctic are being reshaped by significant changes in the operational environment as a result of rising global temperatures and increased development of the vast training ranges available in Alaska. The Arctic is warming faster than any other region on Earth resulting in changing seasonality and precipitation patterns that, in turn, are leading to alterations in above ground vegetation, permafrost stability and summer sea ice extent. Collectively, these poorly defined ecosystem changes play critical roles in affecting the transport and eventual fate of persistent military relevant contaminants through unique Arctic and Subarctic terrestrial environments. As a result, management of military contaminants in a changing Arctic represents a unique and potentially significant liability to the Army and the DoD. The United States footprint in the Arctic region falls within the state of Alaska and U.S. Army Alaska manages 10% of all active Army training lands worldwide, which cover nearly 2,500 square miles in total land area. Primary recalcitrant contaminants of concern at active training ranges and at legacy sites include energetics (i.e. RDX and 2,4-dinitrotoluene) and heavy metals (i.e. antimony and lead). Through a series of field sampling and laboratory experiments, the objectives of this work are to: 1) quantify soil biogeochemical attributes that effect the physical fate and transport of military relevant contaminants in Arctic and subarctic soils under freeze-thaw conditions with a focus on near surface processes, and 2) quantify microbial diversity in Arctic and subarctic soils and the environmental constraints on community activity while exploring the effects of amendments on community function as they relate to contaminant transformation.

  11. CT of thymoma

    International Nuclear Information System (INIS)

    Sone, Shusuke; Higashihara, Tokuro; Morimoto, Shizuo; Ikezoe, Junpei; Arisawa, Jun

    1982-01-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cases with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contoures with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images. (author)

  12. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  13. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  14. Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?

    Energy Technology Data Exchange (ETDEWEB)

    Crop, An de; Hoof, Tom van; Herde, Katharina d' ; Thierens, Hubert; Bacher, Klaus [Ghent University, Department of Basic Medical Sciences, Gent (Belgium); Casselman, Jan; Vereecke, Elke; Bossu, Nicolas [AZ Sint Jan Bruges Ostend AV, Department of Radiology, Bruges (Belgium); Dierens, Melissa [Ghent University, Dental School, Unit for Oral and Maxillofacial Imaging, Ghent (Belgium); Pamplona, Jaime [Hospital Lisboa Central, Department of Neuroradiology, Lisbon (Portugal)

    2015-08-15

    Metal artifacts may negatively affect radiologic assessment in the oral cavity. The aim of this study was to evaluate different metal artifact reduction techniques for metal artifacts induced by dental hardware in CT scans of the oral cavity. Clinical image quality was assessed using a Thiel-embalmed cadaver. A Catphan phantom and a polymethylmethacrylate (PMMA) phantom were used to evaluate physical-technical image quality parameters such as artifact area, artifact index (AI), and contrast detail (IQF{sub inv}). Metal cylinders were inserted in each phantom to create metal artifacts. CT images of both phantoms and the Thiel-embalmed cadaver were acquired on a multislice CT scanner using 80, 100, 120, and 140 kVp; model-based iterative reconstruction (Veo); and synthesized monochromatic keV images with and without metal artifact reduction software (MARs). Four radiologists assessed the clinical image quality, using an image criteria score (ICS). Significant influence of increasing kVp and the use of Veo was found on clinical image quality (p = 0.007 and p = 0.014, respectively). Application of MARs resulted in a smaller artifact area (p < 0.05). However, MARs reconstructed images resulted in lower ICS. Of all investigated techniques, Veo shows to be most promising, with a significant improvement of both the clinical and physical-technical image quality without adversely affecting contrast detail. MARs reconstruction in CT images of the oral cavity to reduce dental hardware metallic artifacts is not sufficient and may even adversely influence the image quality. (orig.)

  15. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  16. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  17. CT of the congenital and spleen acquired abnormalities; TC de las anomalias congenitas y adquiridas del bazo

    Energy Technology Data Exchange (ETDEWEB)

    Gil, A.; Ibarburen, C.; Anton, E.; Temprano, C.; Salgado, F. M.; Davila, J. [Hospital de Mostoles. Madrid (Spain)

    2000-07-01

    This study aims to review the X-ray characteristics of the different entities that can affect the spleen by illustrating the semiology that is seen in the Computed tomography (CT). We review 239 cases of splenic pathology that occurred during a period of 15 years (1985-1999). All of the patients underwent a CT with and without i. v. contrast. Most of the patients were submitted to a splenectomy and histological correlation was performed. The CT is the imaging technique of choice in the diagnosis of splenic diseases since the ultrasonography, although a very sensitive technique, is very inspecific. (Author) 36 refs.

  18. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  19. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  20. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)