  1. Quartz crystal microbalance and photoacoustic measurements in dental photocuring

    Science.gov (United States)

    Lima, Marcenilda A.; Bastos, Ivan N.; Cella, Norberto

    2016-09-01

    Photocured dental resins are used extensively in restorative procedures in dentistry. Inadequate curing reduces the lifetime of the dental restoration, and consequently it is essential to precisely measure the polymerisation kinetics. In this study, two techniques, Quartz Crystal Microbalance (QCM) and Photoacoustic Spectroscopy (PAS), were used to monitor the real-time cure and to obtain the optical absorption spectra of resins, respectively. From the PAS measurements, the precise peaks of absorption were identified, and were used as the appropriate wavelength of the photocuring light in the QCM monitoring. The combined use of these techniques allows reliable determination of the duration of the phases of physical and chemical changes that occur during photocuring. Two commercial dental resins were tested, and the results confirmed the advantages of using PAS and QCM to study polymerisation kinetics.

  2. Quartz Crystal Microbalance Data

    Energy Technology Data Exchange (ETDEWEB)

    Baxamusa, S H

    2011-11-16

    We are using a Qpod quartz crystal microbalance (manufactured by Inficon) for use as a low-volume non-volatile residue analysis tool. Inficon has agreed to help troubleshoot some of our measurements and are requesting to view some sample data, which are attached. The basic principle of an NVR analysis is to evaporate a known volume of solvent, and weigh the remaining residue to determine the purity of the solvent. A typical NVR analysis uses 60 g of solvent and can measure residue with an accuracy of +/- 0.01 mg. The detection limit is thus (0.01 mg)/(60 g) = 0.17 ppm. We are attempting to use a quartz crystal microbalance (QCM) to make a similar measurement. The attached data show the response of the QCM as a 5-20 mg drop of solvent evaporates on its surface. The change in mass registered by the QCM after the drop evaporates is the residue that deposits on the crystal. On some measurements, the change in mass in less than zero, which is aphysical since the drop will leave behind {>=}0 mass of residue. The vendor, Inficon, has agreed to look at these data as a means to help troubleshoot the cause.

  3. The Quartz-Crystal Microbalance in an Undergraduate Laboratory Experiment: Measuring Mass

    Science.gov (United States)

    Tsionsky, Vladimir

    2007-01-01

    The study explains the quartz-crystal microbalance (QCM) technique, which is often used as an undergraduate laboratory experiment for measuring the mass of a system. QCM can be used as a mass sensor only when the measured mass is rigidly attached to the surface.

  4. The Quartz-Crystal Microbalance in an Undergraduate Laboratory Experiment II: Measuring Viscosity

    Science.gov (United States)

    Tsionsky, Vladimir

    2007-01-01

    Various water-alcohol and alcohol-alcohol based experiments are used to demonstrate how the quartz-crystal microbalance (QCM) technique is used for measuring the viscosity of a system. The technique is very advantageous, as it is inexpensive and provides digital output.

  5. Measurement of Total Condensation on a Shrouded Cryogenic Surface using a Single Quart Crystal Microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Haid, B J; Malsbury, T N; Gibson, C R; Warren, C T

    2008-06-10

    A single quartz crystal microbalance (QCM) is cooled to 18 K to measure condensation rates inside of a retractable ''shroud'' enclosure. The shroud is of a design intended to minimize condensate on fusion targets to be fielded at the National Ignition Facility (NIF). The shroud has a double-wall construction with an inner wall that may be cooled to 75-100 K. The QCM and the shroud system were mounted in a vacuum chamber and cooled using a cryocooler. Condensation rates were measured at various vacuum levels and compositions, and with the shroud open or closed. A technique for measuring total condensate during the cooldown of the system with an accuracy of better than 1.0 x 10{sup -6} g/cm{sup 2} was also demonstrated. The technique involved a separate measurement of the condensate-free crystal frequency as a function of temperature that was later applied to the measurement of interest.

  6. Separate density and viscosity measurements of unknown liquid using quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Feng Tan

    2016-09-01

    Full Text Available Aqueous liquids have a wide range of applications in many fields. Basic physical properties like the density and the viscosity have great impacts on the functionalities of a given ionic liquid. For the millions kinds of existing liquids, only a few have been systematically measured with the density and the viscosity using traditional methods. However, these methods are limited to measure the density and the viscosity of an ionic liquid simultaneously especially in processing micro sample volumes. To meet this challenge, we present a new theoretical model and a novel method to separate density and viscosity measurements with single quartz crystal microbalance (QCM in this work. The agreement of experimental results and theocratical calculations shows that the QCM is capable to measure the density and the viscosity of ionic liquids.

  7. In-Line Measurement of Water Content in Ethanol Using a PVA-Coated Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Byoung Chul Kim

    2014-01-01

    Full Text Available An in-line device for measuring the water content in ethanol was developed using a polyvinyl alcohol (PVA-coated quartz crystal microbalance. Bio-ethanol is widely used as the replacement of gasoline, and its water content is a key component of its specifications. When the PVA-coated quartz crystal microbalance is contacted with ethanol containing a small amount of water, the water is absorbed into the PVA increasing the load on the microbalance surface to cause a frequency drop. The determination performance of the PVA-coated microbalance is examined by measuring the frequency decreases in ethanol containing 2% to 10% water while the ethanol flows through the measurement device. The measurements indicates that the higher water content is the more the frequency reduction is, though some deviation in the measurements is observed. This indicates that the frequency measurement of an unknown concentration of water in ethanol can be used to determine the water content in ethanol. The PVA coating is examined by microscopy and FTIR (Fourier transform infrared spectroscopy.

  8. In-line measurement of water content in ethanol using a PVA-coated quartz crystal microbalance.

    Science.gov (United States)

    Kim, Byoung Chul; Yamamoto, Takuji; Kim, Young Han

    2014-01-16

    An in-line device for measuring the water content in ethanol was developed using a polyvinyl alcohol (PVA)-coated quartz crystal microbalance. Bio-ethanol is widely used as the replacement of gasoline, and its water content is a key component of its specifications. When the PVA-coated quartz crystal microbalance is contacted with ethanol containing a small amount of water, the water is absorbed into the PVA increasing the load on the microbalance surface to cause a frequency drop. The determination performance of the PVA-coated microbalance is examined by measuring the frequency decreases in ethanol containing 2% to 10% water while the ethanol flows through the measurement device. The measurements indicates that the higher water content is the more the frequency reduction is, though some deviation in the measurements is observed. This indicates that the frequency measurement of an unknown concentration of water in ethanol can be used to determine the water content in ethanol. The PVA coating is examined by microscopy and FTIR (Fourier transform infrared) spectroscopy.

  9. Effect of a Non-Newtonian Load on Signature S2 for Quartz Crystal Microbalance Measurements

    Directory of Open Access Journals (Sweden)

    Jae-Hyeok Choi

    2014-01-01

    Full Text Available The quartz crystal microbalance (QCM is increasingly used for monitoring the interfacial interaction between surfaces and macromolecules such as biomaterials, polymers, and metals. Recent QCM applications deal with several types of liquids with various viscous macromolecule compounds, which behave differently from Newtonian liquids. To properly monitor such interactions, it is crucial to understand the influence of the non-Newtonian fluid on the QCM measurement response. As a quantitative indicator of non-Newtonian behavior, we used the quartz resonator signature, S2, of the QCM measurement response, which has a consistent value for Newtonian fluids. We then modified De Kee’s non-Newtonian three-parameter model to apply it to our prediction of S2 values for non-Newtonian liquids. As a model, we chose polyethylene glycol (PEG400 with the titration of its volume concentration in deionized water. As the volume concentration of PEG400 increased, the S2 value decreased, confirming that the modified De Kee’s three-parameter model can predict the change in S2 value. Collectively, the findings presented herein enable the application of the quartz resonator signature, S2, to verify QCM measurement analysis in relation to a wide range of experimental subjects that may exhibit non-Newtonian behavior, including polymers and biomaterials.

  10. Measuring Enthalpy of Sublimation of Volatiles by Means of Piezoelectric Crystal Microbalances

    Science.gov (United States)

    Dirri, Fabrizio; Palomba, Ernesto; Longobardo, Andrea; Zampetti, Emiliano

    2016-09-01

    Piezoelectric Crystal Microbalances (PCM's) are widely used to study the chemical processes involving volatile compounds in any environment, such as condensation process. Since PCM's are miniaturized sensor, they are very suitable for planetary in situ missions, where can be used to detect and to measure the mass amount of astrobiologically significant compounds, such as water and organics. This work focuses on the realization and testing of a new experimental setup, able to characterize volatiles which can be found in a planetary environment. In particular the enthalpy of sublimation of some dicarboxylic acids has been measured. The importance of dicarboxylic acids in planetology and astrobiology is due to the fact that they have been detected in carbonaceous chondritic material (e.g. Murchinson), among the most pristine material present in our Solar System. In this work, a sample of acid was heated in an effusion cell up to its sublimation. For a set of temperatures (from 30 °C to 75 °C), the deposition rate on the PCM surface has been measured. From these measurements, it has been possible to infer the enthalpy of sublimation of Adipic acid, i.e. ΔH = 141.6 ± 0.8 kJ/mol and Succinic acid, i.e. ΔH = 113.3 ± 1.3 kJ/mol. This technique has so demonstrated to be a good choice to recognise a single compound or a mixture (with an analysis upstream) even if some improvements concerning the thermal stabilization of the system will be implemented in order to enhance the results' accuracy. The experiment has been performed in support of the VISTA (Volatile In Situ Thermogravimetry Analyzer) project, which is included in the scientific payload of the ESA MarcoPolo-R mission study.

  11. Quartz crystal microbalance for the cardiac markers/antibodies binding kinetic measurements in the plasma samples

    Science.gov (United States)

    Agafonova, L. E.; Shumyantseva, V. V.; Archakov, A. I.

    2014-06-01

    The quartz crystal microbalance (QCM) was exploited for cardiac markers detection and kinetic studies of immunochemical reaction of cardiac troponin I (cTnI) and human heart fatty acid binding protein (H-FABP) with the corresponding monoclonal antibodies in undiluted plasma (serum) and standard solutions. The QCM technique allowed to dynamically monitor the kinetic differences in specific interactions and nonspecific sorption, without multiple labeling procedures and separation steps. The affinity binding process was characterized by the association (ka) and the dissociation (kd) kinetic constants and the equilibrium association (K) constant, all of which were obtained from experimental data.

  12. Lubricity of gold nanocrystals on graphene measured using quartz crystal microbalance

    Science.gov (United States)

    Lodge, M. S.; Tang, C.; Blue, B. T.; Hubbard, W. A.; Martini, A.; Dawson, B. D.; Ishigami, M.

    2016-08-01

    In order to test recently predicted ballistic nanofriction (ultra-low drag and enhanced lubricity) of gold nanocrystals on graphite at high surface speeds, we use the quartz microbalance technique to measure the impact of deposition of gold nanocrystals on graphene. We analyze our measurements of changes in frequency and dissipation induced by nanocrystals using a framework developed for friction of adatoms on various surfaces. We find the lubricity of gold nanocrystals on graphene to be even higher than that predicted for the ballistic nanofriction, confirming the enhanced lubricity predicted at high surface speeds. Our complementary molecular dynamics simulations indicate that such high lubricity is due to the interaction strength between gold nanocrystals and graphene being lower than previously assumed for gold nanocrystals and graphite.

  13. In-Line Measurement of Water Contents in Ethanol Using a Zeolite-Coated Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Byoung Chul Kim

    2015-10-01

    Full Text Available A quartz crystal microbalance (QCM was utilized to measure the water content in ethanol. For the improvement of measurement sensitivity, the QCM was modified by applying zeolite particles on the surface with poly(methyl methacrylate (PMMA binder. The measurement performance was examined with ethanol of 1% to 5% water content in circulation. The experimental results showed that the frequency drop of the QCM was related with the water content though there was some deviation. The sensitivity of the zeolite-coated QCM was sufficient to be implemented in water content determination, and a higher ratio of silicon to aluminum in the molecular structure of the zeolite gave better performance. The coated surface was inspected by microscopy to show the distribution of zeolite particles and PMMA spread.

  14. Quartz crystal microbalance and spectroscopy measurements for acid doping in polyaniline films

    Directory of Open Access Journals (Sweden)

    Mohamad M Ayad and Eman A Zaki

    2008-01-01

    Full Text Available We investigated the doping of thin polyaniline (PANI films, prepared by the chemical oxidation of aniline, with different acids. The initial step in the investigation is the preparation of PANI films from aqueous hydrochloric acid solution. This is followed by dedoping with ammonia to obtain a PANI base, which is subsequently doped with strong acids (e.g. hydrochloric, sulfuric, phosphoric and trichloroacetic acids and with a weak acid (acetic acid. The dopant weight fraction (w, which is connected with the gain of mass during the doping of PANI, was determined in situ using a quartz crystal microbalance (QCM. The behavior of PANI upon doping with different anions derived from strong acids indicates that both proton and the anion uptake into the polymer chains occur sharply, rapidly, completely, and reversibly. However the uptake in the case in acetic acid is characterized by slow diffusion. The doping was studied at different concentrations of acetic acid. A second cycle of dedoping–redoping was also performed. The kinetics of the doping reaction is dominated by Fickian diffusion kinetics. The diffusion coefficients (D of the dopant ions into the PANI chains were determined using the QCM and by UV–Vis absorption spectroscopy in the range of (0.076–1.64× 10−15 cm2 s−1. It was found that D in the second cycle of doping is larger than that evaluated from the first cycle of doping for high concentrations of acetic acid. D for the diffusion and for the dopant ion expulsion from the PANI chains was also determined during the redoping process. It was found that D for acetic acid ions in the doping process is larger than that calculated for the dedoping process.

  15. Data Acquisition System for Quartz Crystal Microbalances

    Directory of Open Access Journals (Sweden)

    Kleber Romero Felizardo

    2006-02-01

    Full Text Available This work presents a data acquisition system used in a mass sensor: quartz crystal microbalance. This system reads the frequency of this sensor along the time and sends the collected data to the computer through a serial interface.

  16. Aerosol effective density measurement using scanning mobility particle sizer and quartz crystal microbalance with the estimation of involved uncertainty

    Science.gov (United States)

    Sarangi, Bighnaraj; Aggarwal, Shankar G.; Sinha, Deepak; Gupta, Prabhat K.

    2016-03-01

    In this work, we have used a scanning mobility particle sizer (SMPS) and a quartz crystal microbalance (QCM) to estimate the effective density of aerosol particles. This approach is tested for aerosolized particles generated from the solution of standard materials of known density, i.e. ammonium sulfate (AS), ammonium nitrate (AN) and sodium chloride (SC), and also applied for ambient measurement in New Delhi. We also discuss uncertainty involved in the measurement. In this method, dried particles are introduced in to a differential mobility analyser (DMA), where size segregation is done based on particle electrical mobility. Downstream of the DMA, the aerosol stream is subdivided into two parts. One is sent to a condensation particle counter (CPC) to measure particle number concentration, whereas the other one is sent to the QCM to measure the particle mass concentration simultaneously. Based on particle volume derived from size distribution data of the SMPS and mass concentration data obtained from the QCM, the mean effective density (ρeff) with uncertainty of inorganic salt particles (for particle count mean diameter (CMD) over a size range 10-478 nm), i.e. AS, SC and AN, is estimated to be 1.76 ± 0.24, 2.08 ± 0.19 and 1.69 ± 0.28 g cm-3, values which are comparable with the material density (ρ) values, 1.77, 2.17 and 1.72 g cm-3, respectively. Using this technique, the percentage contribution of error in the measurement of effective density is calculated to be in the range of 9-17 %. Among the individual uncertainty components, repeatability of particle mass obtained by the QCM, the QCM crystal frequency, CPC counting efficiency, and the equivalence of CPC- and QCM-derived volume are the major contributors to the expanded uncertainty (at k = 2) in comparison to other components, e.g. diffusion correction, charge correction, etc. Effective density for ambient particles at the beginning of the winter period in New Delhi was measured to be 1.28 ± 0.12 g cm-3

  17. Aerosol effective density measurement using scanning mobility particle sizer and quartz crystal microbalance with the estimation of involved uncertainty

    Directory of Open Access Journals (Sweden)

    B. Sarangi

    2015-12-01

    Full Text Available In this work, we have used scanning mobility particle sizer (SMPS and quartz crystal microbalance (QCM to estimate the effective density of aerosol particles. This approach is tested for aerosolized particles generated from the solution of standard materials of known density, i.e. ammonium sulfate (AS, ammonium nitrate (AN and sodium chloride (SC, and also applied for ambient measurement in New Delhi. We also discuss uncertainty involved in the measurement. In this method, dried particles are introduced in to a differential mobility analyzer (DMA, where size segregation was done based on particle electrical mobility. At the downstream of DMA, the aerosol stream is subdivided into two parts. One is sent to a condensation particle counter (CPC to measure particle number concentration, whereas other one is sent to QCM to measure the particle mass concentration simultaneously. Based on particle volume derived from size distribution data of SMPS and mass concentration data obtained from QCM, the mean effective density (ρeff with uncertainty of inorganic salt particles (for particle count mean diameter (CMD over a size range 10 to 478 nm, i.e. AS, SC and AN is estimated to be 1.76 ± 0.24, 2.08 ± 0.19 and 1.69 ± 0.28 g cm−3, which are comparable with the material density (ρ values, 1.77, 2.17 and 1.72 g cm−3, respectively. Among individual uncertainty components, repeatability of particle mass obtained by QCM, QCM crystal frequency, CPC counting efficiency, and equivalence of CPC and QCM derived volume are the major contributors to the expanded uncertainty (at k = 2 in comparison to other components, e.g. diffusion correction, charge correction, etc. Effective density for ambient particles at the beginning of winter period in New Delhi is measured to be 1.28 ± 0.12 g cm−3. It was found that in general, mid-day effective density of ambient aerosols increases with increase in CMD of particle size measurement but particle photochemistry is an

  18. Measuring water adsorption on mineral surfaces in air, CO2, and supercritical CO2 with a quartz-crystal microbalance

    Science.gov (United States)

    Bryan, C. R.; Wells, R. K.; Burton, P. D.; Heath, J. E.; Dewers, T. A.; Wang, Y.

    2011-12-01

    Carbon sequestration via underground storage in geologic formations is a proposed approach for reducing industrial CO2 emissions. However, current models for carbon injection and long-term storage of supercritical CO2 (scCO2) do not consider the development and stability of adsorbed water films at the scCO2-hydrophilic mineral interface. The thickness and properties of the water films control the surface tension and wettability of the mineral surface, and on the core scale, affect rock permeability, saturation, and capillary properties. The film thickness is strongly dependent upon the activity of water in the supercritical fluid, which will change as initially anhydrous scCO2 absorbs water from formation brine. As described in a companion paper by the coauthors, the thickness of the adsorbed water layer is controlled by the disjoining pressure; structural and van der Waals components dominate at low water activity, while electrostatic forces become more important with increasing film thickness (higher water activities). As scCO2 water activity and water layer thickness increase, concomitant changes in mineral surface properties and reservoir/caprock hydrologic properties will affect the mobility of the aqueous phase and of scCO2. Moreover, the development of a water layer may be critical to mineral dissolution reactions in scCO2. Here, we describe the use of a quartz-crystal microbalance (QCM) to monitor adsorption of water by mineral surfaces. QCMs utilize a piezoelectrically-stimulated quartz wafer to measure adsorbed or deposited mass via changes in vibrational frequency. When used to measure the mass of adsorbed liquid films, the frequency response of the crystal must be corrected for the viscoelastic, rather than elastic, response of the adsorbed layer. Results are presented for adsorption to silica in N2 and CO2 at one bar, and in scCO2. Additional data are presented for water uptake by clays deposited on a QCM wafer. In this case, water uptake occurs by the

  19. Reaction-based azide gas sensing with tailored ionic liquids measured by quartz crystal microbalance.

    Science.gov (United States)

    Tseng, Ming-Chung; Chu, Yen-Ho

    2014-02-18

    On the basis of the strain-promoted [3 + 2] cycloaddition reaction performed at ambient temperature, a label-free, online, and chemospecific gas-phase measurement of organic azides in real time was efficiently achieved on QCM chips thin-coated with tailored ionic liquid TIL 1.

  20. Quartz Crystal Microbalance Operation and In Situ Calibration

    Science.gov (United States)

    Albyn, K. C.

    2004-01-01

    Quartz crystal microbalances (QCMs) are commonly used to measure the rate of deposition of molecular species on a surface. The measurement is often used to select materials with a low outgassing rate for applications where the material has a line of sight to a contamination-sensitive surface. A quantitative, in situ calibration of the balance, or balances, using a pure material for which the enthalpy of sublimation is known, is described in this Technical Memorandum. Supporting calculations for surface dwell times of deposited materials and the effusion cell Clausing factor are presented along with examples of multiple QCM measurements of outgassing from a common source.

  1. Coating Characterization with the Quartz Crystal Microbalance

    Science.gov (United States)

    Sturdy, Lauren F.

    The quartz crystal microbalance is a sensitive tool that can be used to measure the mass, modulus and phase angle of films of appropriate thicknesses. It is can be applied to systems with very varied properties, from liquid to solid, and under many different conditions. In this thesis its capabilities have been used to study the properties of several different systems of relevance to the coatings, art conservation, and rubber communities, in the process of which new techniques and tools were developed to analyze data and improve QCM data collection and experimental design. Alkyd resins, which have been used in artists' paints since the twentieth century, are the subject of the first studies. Alkyds are oil-modified polyesters. These resins are of interest because of their relatively recent use in art and how little is known of the mechanical properties in the early stages of cure. The QCM was shown to be sensitive to the curing process, changes in temperature, and mass change due to exposure to water. Kinetic studies during the first days of curing showed that the curing process can be divided into three regions. The first is dominated by solvent evaporation. In the second, oxygen absorption dominates and the mechanical properties change rapidly. The final stage extends from when the film is touch dry after about a day to years and is characterized by mass loss and continued increases in the modulus. Studying the curing at different temperatures revealed that the reactions do proceed much more rapidly at higher temperatures and an overall energy of activation was calculated for the curing process. The mechanical properties of alkyd resins containing zinc oxide, a white pigment, were studied with the QCM, nanoindentation and dynamic mechanical analysis. These measurements showed increases in the modulus with the inclusion of zinc oxide, and the QCM data showed that the second region started at earlier times as the pigment concentration was increased. Linseed oil is

  2. Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Shailesh, E-mail: shailesh.sharma6@mail.dcu.ie [Dublin City University, Glasnevin, Dublin 9 (Ireland); Impedans Limited, Chase House, City Junction Business Park, Northern Cross, D17 AK63, Dublin 17 (Ireland); Gahan, David, E-mail: david.gahan@impedans.com; Scullin, Paul; Doyle, James; Lennon, Jj; Hopkins, M. B. [Impedans Limited, Chase House, City Junction Business Park, Northern Cross, D17 AK63, Dublin 17 (Ireland); Vijayaraghavan, Rajani K.; Daniels, Stephen [Dublin City University, Glasnevin, Dublin 9 (Ireland)

    2016-04-15

    A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

  3. Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance.

    Science.gov (United States)

    Sharma, Shailesh; Gahan, David; Scullin, Paul; Doyle, James; Lennon, Jj; Vijayaraghavan, Rajani K; Daniels, Stephen; Hopkins, M B

    2016-04-01

    A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

  4. Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies

    Directory of Open Access Journals (Sweden)

    Manuel Kasper

    2016-05-01

    Full Text Available We developed an impedance quartz crystal microbalance (QCM approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer. This impedance QCM measures frequency shifts and resistance changes of sensing quartz crystals very stable, accurately, and calibrated, thus yielding quantitative information on mass changes and dissipation. Resistance changes below 0.3 Ω were measured with corresponding dissipation values of 0.01 µU (micro dissipation units. The broadband impedance capabilities allow measurements between 20 Hz and 120 MHz including higher harmonic modes of up to 11th order for a 10 MHz fundamental resonance frequency quartz crystal. We demonstrate the adsorbed mass, calibrated resistance, and quantitative dissipation measurements on two biological systems including the high affinity based avidin-biotin interaction and nano-assemblies of polyelectrolyte layers. The binding affinity of a protein-antibody interaction was determined. The impedance QCM is a versatile and simple method for accurate and calibrated resistance and dissipation measurements with broadband measurement capabilities for higher harmonics measurements.

  5. Decoupling mass adsorption from fluid viscosity and density in quartz crystal microbalance measurements using normalized conductance modeling

    Science.gov (United States)

    Parlak, Z.; Biet, C.; Zauscher, S.

    2013-08-01

    We describe the physical understanding of a method which differentiates between the frequency shift caused by fluid viscosity and density from that caused by mass adsorption in the resonance of a quartz crystal resonator. This method uses the normalized conductance of the crystal to determine a critical frequency at which the fluid mass and fluid loss compensate each other. Tracking the shift in this critical frequency allows us to determine purely mass adsorption on the crystal. We extended this method to Maxwellian fluids for understanding the mass adsorption in non-Newtonian fluids. We validate our approach by real-time mass adsorption measurements using glycerol and albumin solutions.

  6. Separate measurement of the density and viscosity of a liquid using a quartz crystal microbalance based on admittance analysis (QCM-A)

    Science.gov (United States)

    Itoh, Atsushi; Ichihashi, Motoko

    2011-01-01

    We previously used a quartz crystal microbalance (QCM) to identify a frequency f2 that allows measurement of the mass load without being affected by the viscous load of a liquid in the liquid phase. Here, we determined that frequency in order to separately measure the density and viscosity of a Newtonian liquid. Martin et al separately measured the density and viscosity of a liquid by immersing two quartz resonators, i.e. a smooth-surface resonator and a textured-surface resonator, in the liquid. We used a QCM based on admittance analysis (QCM-A) in the current study to separately measure the viscosity and density of a liquid using only a textured-surface resonator. In the current experiments, we measured the density and viscosity of 500 µl of 10%, 30%, and 50% aqueous glycerol solutions and compared the measured values to reference values. The density obtained had an error of ±1.5% of reference values and the viscosity had an error of about ±5% of reference values. Similar results were obtained with 500 µl of 10%, 30%, and 50% ethanol solutions. Measurement was possible with a quartz resonator, so measurements were made with even smaller samples. The density and viscosity of a liquid were successfully determined with an extremely small amount of liquid, i.e. 10 µl, with almost the same precision as when using 500 µl of the liquid.

  7. Application of quartz crystal microbalance technology in tribological investigation

    Science.gov (United States)

    The last fifteen years have seen considerable growth in the application of quartz crystal microbalance (QCM) to explore the tribological characteristics of materials. This article reviews some of the advances made in characterizing frictional properties of materials using the QCM, especially with di...

  8. Results from a Novel Method for Corrosion Studies of Electroplated Lithium Metal Based on Measurements with an Impedance Scanning Electrochemical Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Martin Winter

    2013-07-01

    Full Text Available A new approach to study the chemical stability of electrodeposited lithium on a copper metal substrate via measurements with a fast impedance scanning electrochemical quartz crystal microbalance is presented. The corrosion of electrochemically deposited lithium was compared in two different electrolytes, based on lithium difluoro(oxalato borate (LiDFOB and lithium hexafluorophosphate, both salts being dissolved in solvent blends of ethylene carbonate and diethyl carbonate. For a better understanding of the corrosion mechanisms, scanning electron microscopy images of electrodeposited lithium were also consulted. The results of the EQCM experiments were supported by AC impedance measurements and clearly showed two different corrosion mechanisms caused by the different salts and the formed SEIs. The observed mass decrease of the quartz sensor of the LiDFOB-based electrolyte is not smooth, but rather composed of a series of abrupt mass fluctuations in contrast to that of the lithium hexafluorophosphate-based electrolyte. After each slow decrease of mass a rather fast increase of mass is observed several times. The slow mass decrease can be attributed to a consolidation process of the SEI or to the partial dissolution of the SEI leaving finally lithium metal unprotected so that a fast film formation sets in entailing the observed fast mass increases.

  9. The quartz crystal microbalance in soft matter research fundamentals and modeling

    CERN Document Server

    Johannsmann, Diethelm

    2014-01-01

    This book describes the physics of the second-generation quartz crystal microbalance (QCM), a fundamental method of analysis for soft matter at interfaces.From a device for measuring film thickness in vacuum, the quartz crystal microbalance (QCM) has in the past two decades evolved into a versatile instrument for analyzing soft matter at solid/liquid and solid/gas interfaces that found applications in diverse fields including the life sciences, material science, polymer research and electrochemistry. As a consequence of this success, the QCM is now being used by scientists with a wide variety

  10. A combined nanoplasmonic and electrodeless quartz crystal microbalance setup

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Elin M.; Langhammer, Christoph; Zoric, Igor; Kasemo, Bengt [Department of Applied Physics, Chemical Physics Group, Chalmers University of Technology, SE-41296 Gothenburg (Sweden); Edvardsson, Malin E. M. [Department of Applied Physics, Biological Physics Group, Chalmers University of Technology, SE-41296 Gothenburg (Sweden)

    2009-12-15

    We have developed an instrument combining localized surface plasmon resonance (LSPR) sensing with electrodeless quartz crystal microbalance with dissipation monitoring (QCM-D). The two techniques can be run simultaneously, on the same sensor surface, and with the same time resolution and sensitivity as for the individual techniques. The electrodeless QCM eliminates the need to fabricate electrodes on the quartz crystal and gives a large flexibility in choosing the surface structure and coating for both QCM-D and LSPR. The performance is demonstrated for liquid phase measurements of lipid bilayer formation and biorecognition events, and for gas phase measurements of hydrogen uptake/release by palladium nanoparticles. Advantages of using the combined equipment for biomolecular adsorption studies include synchronized information about structural transformations and extraction of molecular (dry) mass and degree of hydration of the adlayer, which cannot be obtained with the individual techniques. In hydrogen storage studies the combined equipment, allows for synchronized measurements of uptake/release kinetics and quantification of stored hydrogen amounts in nanoparticles and films at practically interesting hydrogen pressures and temperatures.

  11. Ion effects in the adsorption of carboxylate on oxide surfaces, studied with quartz crystal microbalance

    NARCIS (Netherlands)

    Wang, Lei; Siretanu, Igor; Duits, Michel H.G.; Cohen Stuart, Martien A.; Mugele, Frieder

    2016-01-01

    We chose water-soluble sodium hexanoate as a model organic molecule to study the role of salt ions (Ca2+, Na+, Cl−) in the adsorption of carboxylates to mineral surfaces (silica, alumina, gibbsite) of variable surface charge and chemistry. Quartz crystal microbalance (QCM-D) measurements reveal a qu

  12. Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors.

    Science.gov (United States)

    Emir Diltemiz, Sibel; Keçili, Rüstem; Ersöz, Arzu; Say, Rıdvan

    2017-02-24

    Molecularly imprinted polymers (MIPs) as artificial antibodies have received considerable scientific attention in the past years in the field of (bio)sensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values, etc.). On the other hand, the Quartz Crystal Microbalance (QCM) is an analytical tool based on the measurement of small mass changes on the sensor surface. QCM sensors are practical and convenient monitoring tools because of their specificity, sensitivity, high accuracy, stability and reproducibility. QCM devices are highly suitable for converting the recognition process achieved using MIP-based memories into a sensor signal. Therefore, the combination of a QCM and MIPs as synthetic receptors enhances the sensitivity through MIP process-based multiplexed binding sites using size, 3D-shape and chemical function having molecular memories of the prepared sensor system toward the target compound to be detected. This review aims to highlight and summarize the recent progress and studies in the field of (bio)sensor systems based on QCMs combined with molecular imprinting technology.

  13. Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM Sensors

    Directory of Open Access Journals (Sweden)

    Sibel Emir Diltemiz

    2017-02-01

    Full Text Available Molecularly imprinted polymers (MIPs as artificial antibodies have received considerable scientific attention in the past years in the field of (biosensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values, etc.. On the other hand, the Quartz Crystal Microbalance (QCM is an analytical tool based on the measurement of small mass changes on the sensor surface. QCM sensors are practical and convenient monitoring tools because of their specificity, sensitivity, high accuracy, stability and reproducibility. QCM devices are highly suitable for converting the recognition process achieved using MIP-based memories into a sensor signal. Therefore, the combination of a QCM and MIPs as synthetic receptors enhances the sensitivity through MIP process-based multiplexed binding sites using size, 3D-shape and chemical function having molecular memories of the prepared sensor system toward the target compound to be detected. This review aims to highlight and summarize the recent progress and studies in the field of (biosensor systems based on QCMs combined with molecular imprinting technology.

  14. Quartz Crystal Microbalance: A tool for analyzing loss of volatile compounds, gas sorption, and curing kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Bajric, Sendin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    Los Alamos National Laboratory (LANL) has recently procured a quartz crystal microbalance (QCM). Current popular uses are biological sensors, surface chemistry, and vapor detection. LANL has projects related to analyzing curing kinetics, measuring gas sorption on polymers, and analyzing the loss of volatile compounds in polymer materials. The QCM has yet to be employed; however, this review will cover the use of the QCM in these applications and its potential.

  15. Adsorption kinetics of laponite and ludox silica nanoparticles onto a deposited poly(diallyldimethylammonium chloride) layer measured by a quartz crystal microbalance and optical reflectometry.

    Science.gov (United States)

    Xu, Dan; Hodges, Chris; Ding, Yulong; Biggs, Simon; Brooker, Anju; York, David

    2010-12-07

    A quartz crystal microbalance with dissipation (QCM-D) and an optical reflectometer (OR) have been used to investigate the adsorption behavior of Laponite and Ludox silica nanoparticles at the solid-liquid interface. The adsorption of both Laponite and Ludox silica onto poly(diallyldimethylammonium chloride) (PDADMAC)-coated surfaces over the first few seconds were studied by OR. Both types of nanoparticles adsorbed rapidly and obtained a stable adsorbed amount after only a few minutes. The rate of adsorption for both nanoparticle types was concentration dependent. The maximum adsorption rate of Ludox nanoparticles was found to be approximately five times faster than that for Laponite nanoparticles. The QCM data for the Laponite remained stable after the initial adsorption period at each concentration tested. The observed plateau values for the frequency shifts increased with increasing Laponite particle concentration. The QCM data for the Ludox nanoparticles had a more complex long-time behavior. In particular, the dissipation data at 3 ppm and 10 ppm Ludox increased slowly with time, never obtaining a stable value within the duration of the experiment. We postulate here that this is caused by slow structural rearrangements of the particles and the PDADMAC within the surface adsorbed layer. Furthermore, the QCM dissipation values were significantly smaller for Laponite when compared with those for Ludox for all nanoparticle concentrations, suggesting that the Laponite adsorbed layer is more compact and more rigidly bound than the Ludox adsorbed layer.

  16. Performances and limits of a parallel oscillator for electrochemical quartz crystal microbalances.

    Science.gov (United States)

    Ehahoun, Hervé; Gabrielli, Claude; Keddam, Michel; Perrot, Hubert; Rousseau, Philippe

    2002-03-01

    This paper describes a driving circuit for an electrochemical quartz crystal microbalance (EQCM) adapted to a wide range of applications. The oscillator is a Miller-type parallel oscillator using an operational transconductance amplifier (OTA). A theoretical study of the oscillating circuit led to the analytical expression of the microbalance frequency as well as to an overestimation of the error on the mass measurement. The reliability of the EQCM was then experimentally verified through electrochemical copper deposition and dissolution. The limit of operation of the EQCM was also investigated, both analytically and experimentally. This work shows that parallel oscillators using few electronic components allow a very reliable EQCM to be obtained for mass measurements on metallic films, even if they are highly damped.

  17. Respiratory Monitoring by Porphyrin Modified Quartz Crystal Microbalance Sensors

    Directory of Open Access Journals (Sweden)

    Seung-Woo Lee

    2011-01-01

    Full Text Available A respiratory monitoring system based on a quartz crystal microbalance (QCM sensor with a functional film was designed and investigated. Porphyrins 5,10,15,20-tetrakis-(4-sulfophenyl-21H,23H-porphine (TSPP and 5,10,15,20-tetrakis-(4-sulfophenyl-21H, 23H-porphine manganese (III chloride (MnTSPP used as sensitive elements were assembled with a poly(diallyldimethyl ammonium chloride (PDDA. Films were deposited on the QCM resonators using layer-by-layer method in order to develop the sensor. The developed system, in which the sensor response reflects lung movements, was able to track human respiration providing respiratory rate (RR and respiratory pattern (RP. The sensor system was tested on healthy volunteers to compare RPs and calculate RRs. The operation principle of the proposed system is based on the fast adsorption/desorption behavior of water originated from human breath into the sensor films deposited on the QCM electrode.

  18. Frequency Behavior of a Quartz Crystal Microbalance (Qcm in Contact with Selected Solutions

    Directory of Open Access Journals (Sweden)

    Z. A. Talib

    2006-01-01

    Full Text Available A device was constructed to monitor viscosity of solutions using fundamental frequency of 9 MHz and 10 MHz quartz crystal. Piezoelectric quartz crystals with gold electrodes were mounted by O-ring in between liquid flow cell. Only one side of the crystal was exposed to the solutions which were pumped through silicon tube by a peristaltic pump. The measured frequency shift was observed in order to investigate the interfacial behavior of some selected solution in contact with one surface of Quartz Crystal Microbalance (QCM. An analysis of the interaction between an AT-cut quartz crystal microbalance and various liquid system of analytical interest is presented. The analysis which includes piezoelectric effects and other influences; liquid properties, experimental conditions and the characteristic of the solution are reported. Oscillation in distilled water is taken as a reference. The frequency change caused by the density (ρ, gcm-3 and viscosity (η gcm-1s-1 were found to be proportional to the square root of the product, (ρ η. The result suggested that analysis of small frequency shifts during EQCM studies needs to account for changes in ρ and η of the solution. Generally, all the liquid tested showed an increment of the frequency shift with increasing content of solutes. For each solution, the frequency was recorded as the concentration increases from distilled water to a very concentrated solution. The frequency measurements carried out for saccharide solution produces the maximum changes of frequency shift compared with other solutions.

  19. Quartz Crystal Microbalance with Dissipation (QCM-D) studies of the viscoelastic response from a continuously growing grafted polyelectrolyte layer

    DEFF Research Database (Denmark)

    Dunér, Gunnar; Thormann, Esben; Dedinaite, Andra

    2013-01-01

    Poly(acrylic acid) was grown from substrates by photopolymerization, and the grafting process was monitored in situ by Quartz Crystal Microbalance with Dissipation (QCM-D) measurements in a 1:1 v/v mixture of water/ethanol. The polymerization process was monitored into the thick film region, where...

  20. A New Quartz Crystal Microbalance Measuring Method with Expansive Frequency Range and Broadband Adaptive Response Capacity%新型宽频自适应石英晶体微天平测量方法

    Institute of Scientific and Technical Information of China (English)

    周俊鹏; 包宇; 林青; 逄仁山; 王连明; 牛利

    2014-01-01

    In order to solve the problems of present quartz crystal microbalance ( QCM ) measuring instruments, such as high demand for crystal cutting technology and uncomprehensive measurements for crystal parameters, a modified quadrature demodulation-based method was proposed with broadband adaptive response capacity and high frequency resolution. Moreover, it is also capable of measuring both resonant frequencies and dissipation factor D synchronously and continuously. Experimental results at room temperature indicated that the adaptive frequency range was 1-9 MHz while the frequency resolution was less than 1 Hz, measured resonance frequency shifts of crystals in the range scale linearly with the equal thickness increments of poly acrylic acid ( PAA) membrane on the working electrode, and with the volatilization of different solvent factor D is measured continuously and effectively along the time axis. To sum up, compared with traditional ones, this new method has lower material cost and more obtained parameters.%针对目前石英晶体微天平( Quartz crystal microbalance,QCM)仪器所存在的对晶体切割工艺要求过高,测量参数不够全面等问题,在正交解调法的基础上,提出了一种在较宽频率范围内具有自适应功能,测量频率分辨率高,并且可同时连续获取谐振频率和耗散因子D的测试方法。实验表明:室温下,频率测量自适应范围在1~9 MHz且频率分辨率小于1 Hz;随着工作电极聚丙烯酸( Poly acrylic acid,PAA)膜厚度的均匀叠加,测得范围内各晶体频率偏移呈线性变化;随着不同溶剂挥发,D因子测量结果在时间轴上连续有效。与传统方法相比,本方法具有耗材成本低,获取参数丰富等优点。

  1. The Quartz-Crystal Microbalance in an Undergraduate Laboratory Experiment: I. Fundamentals and Instrumentation

    Science.gov (United States)

    Tsionsky, Vladimir

    2007-01-01

    The fundamentals, as well as the instrumentation of the quartz-crystal microbalance (QCM) technique that is used in an undergraduate laboratory experiment are being described. The QCM response can be easily used to change the properties of any system.

  2. Ultrasensitive quartz crystal microbalance integrated with carbon nanotubes

    Science.gov (United States)

    Goyal, Abhijat

    In this thesis, an ultrasensitive Quartz Crystal Microbalance (QCM) which can be configured as a versatile (bio)chemical sensor is presented. The high sensitivity of the QCM was achieved via miniaturization using micromachining techniques. The absolute mass sensitivity of sensor was increased by decreasing the thickness and the area of the electrodes of the resonators. Through optimal design, microfabrication, and miniaturization the mass sensitivity of the sensors was increased by more than four orders of magnitude to less than 1 pg/Hz; as compared to 17 ng/Hz for commercially available 5 MHz bulk resonators. Miniaturization of the resonators enables their fabrication in an array format with each pixel of the array being individually addressed. This enables true spatial and temporal mass sensing capabilities. The fabricated resonators were tested for operation in air and water and high quality factors of 7500 and ˜2000 were obtained respectively. A dielectric etch process was developed to achieve the miniaturization of the sensors. The optimization of the dielectric etch process was achieved using statistical techniques such as Design of Experiment (DOE). An etch rate of 0.5 microm/min at rms surface roughness of less than 2 nm was achieved after the optimization process. The process parameters, namely the ICP power, the substrate power, the flow rate of gases, the operating pressure of the etch tool, distance of substrate holder from the source, and the temperature of substrate holder, were quantitatively related to the etch rate and rms surface roughness using least square fit to the etch data. The QCMs were integrated with carbon nanotubes using a simple spray-on technique. It was found that the addition of carbon nanotubes onto the electroded surface of the resonator increased its Q-factor by as much as 100%. It was proposed that the carbon nanotubes due to their high stiffness suppress the out-of-plane flexural vibrations in the QCMs thereby suppressing an

  3. Quartz Crystal Microbalances for quantitative picosecond laser-material-interaction investigations - Part I: Technical considerations

    Science.gov (United States)

    Gierse, N.; Schildt, T.; Esser, H. G.; Sergienko, G.; Brezinsek, S.; Freisinger, M.; Zhao, D.; Ding, H.; Terra, A.; Samm, U.; Linsmeier, Ch.

    2016-12-01

    In this work the technical suitability of Quartz Crystal Microbalances (QMBs) for in situ, pulse resolved mass removal measurements is demonstrated for picosecond laser ablation of magnetron sputtered coatings. The QMBs show a linear characteristic of the sensitivity for layer thickness of different metals up to several microns. Laser pulse resolved measurements of the mass ablated from the metal layer were performed. About 400 ng of chromium was ablated during the first laser pulse while in subsequent pulses ablation of the QMBs is found to be larger than for deposition, which is explained by the radial sensitivity of the QMBs. Future refinements of the setup and the benefits of the pulse resolved mass loss measurements for laser based methods like LIBS and LIAS are discussed and will be presented in part II currently in preparation.

  4. Quantitative determination of hydrogen absorption by Pd cluster-assembled films using a quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    El Far, R.; Diaz-Droguett, D.E.; Rojas, S.; Avila, J.I. [Laboratorio de Ciencia de Materiales, Facultad de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile); Romero, C.P.; Lievens, P. [Laboratorium voor Vaste-Stoffysica en Magnetisme, KU Leuven, Celestijnenlaan 200D-bus 2414 B-3001 Leuven (Belgium); Cabrera, A.L., E-mail: acabrera@fis.puc.cl [Laboratorio de Ciencia de Materiales, Facultad de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile)

    2012-11-01

    We have measured hydrogen absorption capacity for a series of Pd films grown by two deposition techniques: a) flat films made with e-beam evaporation of Pd and b) films made of assembled Pd clusters. The films range in thickness from 9.5 to 45 nm. The technique implemented for measuring the amount of hydrogen absorbed by the films was a quartz crystal microbalance. The Pd films were grown on the quartz crystals and the change of mass due to the hydrogen absorption was determined from the shifting of the resonance frequency. Minute amounts of hydrogen absorbed of the order of nanograms per square centimeter can be detected by this technique. Plots of H/Pd atom ratio for each Pd film as a function of hydrogen pressure were obtained. The Pd e-beam grown films displayed a saturation H/Pd atomic ratio around 0.6 which is similar to bulk Pd. The Pd cluster film with a thickness of 14 nm displayed a remarkable absorption capacity with a ratio H/(Pd) Almost-Equal-To 0.84. - Highlights: Black-Right-Pointing-Pointer Pd cluster assembled films with different thicknesses are made and characterized. Black-Right-Pointing-Pointer Quartz crystal microbalance is used to quantification the hydrogen amount absorbed. Black-Right-Pointing-Pointer Hydrogen absorption/adsorption by Pd film is explained. Black-Right-Pointing-Pointer Absorption expressed in H/Pd mass ratio is given for all Pd films. Black-Right-Pointing-Pointer This complements H{sub 2} absorption on metal cluster films using optical techniques.

  5. Electrochemical quartz crystal microbalance (EQCM) study of ion dynamics in nanoporous carbons.

    Science.gov (United States)

    Tsai, Wan-Yu; Taberna, Pierre-Louis; Simon, Patrice

    2014-06-18

    Electrochemical quartz crystal microbalance (EQCM) and cyclic voltammetry (CV) measurements were used to characterize ion adsorption in carbide-derived carbon (CDC) with two different average pore sizes (1 and 0.65 nm), from neat and solvated 1-Ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (EMI-TFSI) electrolytes. From the electrode mass change in neat EMI-TFSI, it was shown that one net charge stored corresponds almost to one single ion at high polarization; in that case, no ion-pairing or charge screening by co-ions were observed. In 2 M EMI-TFSI in acetonitrile electrolyte, experimental solvation numbers were estimated for EMI(+) cation, showing a partial desolvation when cations were adsorbed in confined carbon pores. The extent of desolvation increased when decreasing the carbon pore size (from 1 down to 0.65 nm). The results also suggest that EMI(+) cation owns higher mobility than TFSI(-) anion in these electrolytes.

  6. Electrochemical Quartz Crystal Microbalance Monitoring of the Cyclic Voltammetric Deposition of Polyaniline

    Science.gov (United States)

    Xie, Qingji; Li, Zhili; Deng, Chunyan; Liu, Meiling; Zhang, Youyu; Ma, Ming; Xia, Shaoxi; Xiao, Xiaoming; Yin, Dulin; Yao, Shouzhuo

    2007-01-01

    A real-time, labeled-free and nanogram-sensitive mass sensor, electrochemical quartz crystal microbalance (EQCM) is used to monitor a cyclic voltammetric deposition of polyaniline (PANI). The results determined that the efficiency for PANI deposition and the anion-doping ratio is calculated in one single cyclic voltammetric.

  7. Rapid identification of spinal ventral and dorsal roots using a quartz crystal microbalance

    Institute of Scientific and Technical Information of China (English)

    Tao Sui; Jun Que; Dechao Kong; Hao Xie; Daode Wang; Kun Shi; Xiaojian Cao; Xiang Li

    2013-01-01

    The fast and accurate identification of nerve tracts is critical for successful nerve anastomosis. Taking advantage of differences in acetylcholinesterase content between the spinal ventral and dorsal roots, we developed a novel quartz crystal microbalance method to distinguish between these nerves based on acetylcholinesterase antibody reactivity. The acetylcholinesterase antibody was immobilized on the electrode surface of a quartz crystal microbalance and reacted with the acetylcholinesterase in sample solution. The formed antigen and antibody complexes added to the mass of the electrode inducing a change in frequency of the electrode. The spinal ventral and dorsal roots were distinguished by the change in frequency. The ventral and dorsal roots were cut into 1 to 2-mm long segments and then soaked in 250 μL PBS. Acetylcholinesterase antibody was immobilized on the quartz crystal microbalance gold electrode surface. The results revealed that in 10 minutes, both spinal ventral and dorsal roots induced a frequency change; however, the frequency change induced by the ventral roots was notably higher than that induced by the dorsal roots. No change was induced by bovine serum albumin or PBS. These results clearly demonstrate that a quartz crystal microbalance sensor can be used as a rapid, highly sensitive and accurate detection tool for the quick identification of spinal nerve roots intraoperatively.

  8. Quartz Crystal Microbalance Technique for in Situ Analysis of Supersaturation in Cooling Crystallization.

    Science.gov (United States)

    Liu, Li-Shang; Kim, Jong-Min; Kim, Woo-Sik

    2016-06-07

    A quartz crystal microbalance (QCM) is used as a novel in situ strategy for analyzing the supersaturation profile during cooling crystallization. The main concept is based on preventing any solid mass loading on the QCM sensor by modifying the sensor surface. As a result, the QCM responses only depend on the solution concentration changes during the crystallization. The proposed strategy is confirmed on the basis of an analysis of sulfamerazine (SMZ) crystallization. When the QCM sensor is modified using 11-amino-1-undecanethiol (AUT), crystal formation on the sensor is completely prevented due to a repulsive interaction between the -NH2 functional groups of the AUT and SMZ crystals. Thus, the QCM responses reflect only the property changes in the solution phase during the crystallization. The supersaturation in the solution is then estimated on the basis of the difference in the frequency shifts between the SMZ solution and a blank solution. The accuracy of the in situ QCM analysis of supersaturation is confirmed using an off-line gravimetric method.

  9. Low-cost scalable quartz crystal microbalance array for environmental sensing

    Energy Technology Data Exchange (ETDEWEB)

    Anazagasty, Cristain [University of Puerto Rico; Hianik, Tibor [Comenius University, Bratislava, Slovakia; Ivanov, Ilia N [ORNL

    2016-01-01

    Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution (~1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.

  10. Low-cost scalable quartz crystal microbalance array for environmental sensing

    Science.gov (United States)

    Muckley, Eric S.; Anazagasty, Cristain; Jacobs, Christopher B.; Hianik, Tibor; Ivanov, Ilia N.

    2016-09-01

    Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution ( 1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.

  11. Development of a Quartz Crystal Microbalance Biosensor with Aptamers as Bio-recognition Element

    Directory of Open Access Journals (Sweden)

    Chunyan Yao

    2010-06-01

    Full Text Available The ultimate goal in any biosensor development project is its use for actual sample detection. Recently, there has been an interest in biosensors with aptamers as bio-recognition elements, but reported examples all deal with standards, not human serum. In order to verify the differences of aptamer-based biosensor and antibody-based biosensor in clinical detection, a comparison of the performance of aptamer-based and antibody-based quartz crystal microbalance (QCM biosensors for the detection of immunoglobulin E (IgE in human serum was carried out. Aptamers (or antibodies specific to IgE were immobilized on the gold surface of a quartz crystal. The frequency shifts of the QCM were measured. The linear range with the antibody (10–240 μg/L compared to that of the aptamer (2.5–200 μg/L, but a lower detection limit could be observed in the aptamer-based biosensor. The reproducibility of the two biosensors was comparable. The aptamers were equivalent or superior to antibodies in terms of specificity and sensitivity. In addition, the aptamer receptors could tolerate repeated affine layer regeneration after ligand binding and recycling of the biosensor with little loss of sensitivity. When stored for three weeks, the frequency shifts of the aptamer-coated crystals were all greater than 90% of those on the response at the first day.

  12. Hydrolysis of model cellulose films by cellulosomes: Extension of quartz crystal microbalance technique to multienzymatic complexes.

    Science.gov (United States)

    Zhou, Shanshan; Li, Hsin-Fen; Garlapalli, Ravinder; Nokes, Sue E; Flythe, Michael; Rankin, Stephen E; Knutson, Barbara L

    2017-01-10

    Bacterial cellulosomes contain highly efficient complexed cellulases and have been studied extensively for the production of lignocellulosic biofuels and bioproducts. A surface measurement technique, quartz crystal microbalance with dissipation (QCM-D), was extended for the investigation of real-time binding and hydrolysis of model cellulose surfaces from free fungal cellulases to the cellulosomes of Clostridium thermocellum (Ruminiclostridium thermocellum). In differentiating the activities of cell-free and cell-bound cellulosomes, greater than 68% of the cellulosomes in the crude cell broth were found to exist unattached to the cell across multiple growth stages. The initial hydrolysis rate of crude cell broth measured by QCM was greater than that of cell-free cellulosomes, but the corresponding frequency drop (a direct measure of the mass of enzyme adsorbed to the film) of crude cell broth was less than that of the cell-free cellulosomes, consistent with the underestimation of the cell mass adsorbed using QCM. Inhibition of hydrolysis by cellobiose (0-10g/L), which is similar for crude cell broth and cell-free cellulosomes, demonstrates the sensitivity of the QCM to environmental perturbations of multienzymatic complexes. QCM measurements using multienzymatic complexes may be used to screen and optimize hydrolysis conditions and to develop mechanistic, surface-based models of enzymatic cellulose deconstruction. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Protein Adsorption to Titanium and Zirconia Using a Quartz Crystal Microbalance Method

    Directory of Open Access Journals (Sweden)

    You Kusakawa

    2017-01-01

    Full Text Available Protein adsorption onto titanium (Ti or zirconia (ZrO2 was evaluated using a 27 MHz quartz crystal microbalance (QCM. As proteins, fibronectin (Fn, a cell adhesive protein, and albumin (Alb, a cell adhesion-inhibiting protein, were evaluated. The Ti and ZrO2 sensors for QCM were characterized by atomic force microscopy and electron probe microanalysis observation, measurement of contact angle against water, and surface roughness. The amounts of Fn and Alb adsorbed onto the Ti and ZrO2 sensors and apparent reaction rate were obtained using QCM measurements. Ti sensor showed greater adsorption of Fn and Alb than the ZrO2 sensor. In addition, amount of Fn adsorbed onto the Ti or ZrO2 sensors was higher than that of Alb. The surface roughness and hydrophilicity of Ti or ZrO2 may influence the adsorption of Fn or Alb. With regard to the adsorption rate, Alb adsorbed more rapidly than Fn onto Ti. Comparing Ti and ZrO2, Alb adsorption rate to Ti was faster than that to ZrO2. Fn adsorption will be effective for cell activities, but Alb adsorption will not. QCM method could simulate in vivo Fn and Alb adsorption to Ti or ZrO2.

  14. Protein Adsorption to Titanium and Zirconia Using a Quartz Crystal Microbalance Method

    Science.gov (United States)

    Kusakawa, You

    2017-01-01

    Protein adsorption onto titanium (Ti) or zirconia (ZrO2) was evaluated using a 27 MHz quartz crystal microbalance (QCM). As proteins, fibronectin (Fn), a cell adhesive protein, and albumin (Alb), a cell adhesion-inhibiting protein, were evaluated. The Ti and ZrO2 sensors for QCM were characterized by atomic force microscopy and electron probe microanalysis observation, measurement of contact angle against water, and surface roughness. The amounts of Fn and Alb adsorbed onto the Ti and ZrO2 sensors and apparent reaction rate were obtained using QCM measurements. Ti sensor showed greater adsorption of Fn and Alb than the ZrO2 sensor. In addition, amount of Fn adsorbed onto the Ti or ZrO2 sensors was higher than that of Alb. The surface roughness and hydrophilicity of Ti or ZrO2 may influence the adsorption of Fn or Alb. With regard to the adsorption rate, Alb adsorbed more rapidly than Fn onto Ti. Comparing Ti and ZrO2, Alb adsorption rate to Ti was faster than that to ZrO2. Fn adsorption will be effective for cell activities, but Alb adsorption will not. QCM method could simulate in vivo Fn and Alb adsorption to Ti or ZrO2. PMID:28246591

  15. Protein Adsorption to Titanium and Zirconia Using a Quartz Crystal Microbalance Method.

    Science.gov (United States)

    Kusakawa, You; Yoshida, Eiji; Hayakawa, Tohru

    2017-01-01

    Protein adsorption onto titanium (Ti) or zirconia (ZrO2) was evaluated using a 27 MHz quartz crystal microbalance (QCM). As proteins, fibronectin (Fn), a cell adhesive protein, and albumin (Alb), a cell adhesion-inhibiting protein, were evaluated. The Ti and ZrO2 sensors for QCM were characterized by atomic force microscopy and electron probe microanalysis observation, measurement of contact angle against water, and surface roughness. The amounts of Fn and Alb adsorbed onto the Ti and ZrO2 sensors and apparent reaction rate were obtained using QCM measurements. Ti sensor showed greater adsorption of Fn and Alb than the ZrO2 sensor. In addition, amount of Fn adsorbed onto the Ti or ZrO2 sensors was higher than that of Alb. The surface roughness and hydrophilicity of Ti or ZrO2 may influence the adsorption of Fn or Alb. With regard to the adsorption rate, Alb adsorbed more rapidly than Fn onto Ti. Comparing Ti and ZrO2, Alb adsorption rate to Ti was faster than that to ZrO2. Fn adsorption will be effective for cell activities, but Alb adsorption will not. QCM method could simulate in vivo Fn and Alb adsorption to Ti or ZrO2.

  16. Development of a Flow Injection Based High Frequency Dual Channel Quartz Crystal Microbalance.

    Science.gov (United States)

    Liang, Jinxing; Zhang, Jing; Zhou, Wenxiang; Ueda, Toshitsugu

    2017-05-16

    When the quartz crystal microbalance (QCM) is used in liquid for adsorption or desorption monitoring based bio- or chemical sensing applications, the frequency shift is not only determined by the surface mass change, but also by the change of liquid characteristics, such as density and viscosity, which are greatly affected by the liquid environmental temperature. A monolithic dual-channel QCM is designed and fabricated by arranging two QCM resonators on one single chip for cancelling the fluctuation induced by environmental factors. In actual applications, one QCM works as a specific sensor by modifying with functional membranes and the other acts as a reference, only measuring the liquid property. The dual-channel QCM is designed with an inverted-mesa structure, aiming to realize a high frequency miniaturized chip and suppress the frequency interference between the neighbored QCM resonators. The key problem of dual-channel QCMs is the interference between two channels, which is influenced by the distance of adjacent resonators. The diameter of the reference electrode has been designed into several values in order to find the optimal parameter. Experimental results demonstrated that the two QCMs could vibrate individually and the output frequency stability and drift can be greatly improved with the aid of the reference QCM.

  17. A novel assay for detecting canine parvovirus using a quartz crystal microbalance biosensor.

    Science.gov (United States)

    Kim, Yong Kwan; Lim, Seong-In; Choi, Sarah; Cho, In-Soo; Park, Eun-Hye; An, Dong-Jun

    2015-07-01

    Rapid and accurate diagnosis is crucial to reduce both the shedding and clinical signs of canine parvovirus (CPV). The quartz crystal microbalance (QCM) is a new tool for measuring frequency changes associated with antigen-antibody interactions. In this study, the QCM biosensor and ProLinker™ B were used to rapidly diagnosis CPV infection. ProLinker™ B enables antibodies to be attached to a gold-coated quartz surface in a regular pattern and in the correct orientation for antigen binding. Receiver operating characteristics (ROC) curves were used to set a cut-off value using reference CPVs (two groups: one CPV-positive and one CPV-negative). The ROC curves overlapped and the point of intersection was used as the cut-off value. A QCM biosensor with a cut-off value of -205 Hz showed 95.4% (104/109) sensitivity and 98.0% (149/152) specificity when used to test 261 field fecal samples compared to PCR. In conclusion, the QCM biosensor described herein is eminently suitable for the rapid diagnosis of CPV infection with high sensitivity and specificity. Therefore, it is a promising analytical tool that will be useful for clinical diagnosis, which requires rapid and reliable analyses.

  18. A hybrid humidity sensor using optical waveguides on a quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Shinbo, Kazunari, E-mail: kshinbo@eng.niigata-u.ac.j [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Otuki, Shunya; Kanbayashi, Yuichi [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Ohdaira, Yasuo [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Baba, Akira [Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Kato, Keizo; Kaneko, Futao [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Miyadera, Nobuo [Hitachi Chemical Co., Ltd., 48 Wadai, Tsukuba City, Ibaraki 300-4247 (Japan)

    2009-11-30

    In this study, slab and ridge optical waveguides (OWGs) made of fluorinated polyimides were deposited on a quartz crystal microbalance (QCM), and hybrid sensors using OWG spectroscopy and the QCM technique were prepared. Polyvinyl alcohol (PVA) film with CoCl{sub 2} was deposited on the OWGs, and the characteristics of humidity sensing were investigated. A prism coupler was used to enter a He-Ne laser beam ({lambda} = 632.8 nm) to the slab OWG. The output light intensity markedly changed due to chromism of the CoCl{sub 2} as a result of humidity sorption, and this change was dependent on the incident angle of the laser beam to the slab OWG. During the measurement of output light, the QCM frequency was simultaneously monitored. The humidity dependence of the sensor with the slab OWG was also investigated in the range from 15 to 85%. For the sensor with the ridge OWG, white light was entered by butt-coupling, and the characteristics of humidity sensing were investigated by observing the output light spectrum and the QCM frequency.

  19. Detection of sulfur dioxide using a piezoelectric quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, O.M. [Instituto de Quimica de Sao Carlos (Brazil)

    1997-09-01

    Sulfur dioxide was detected and determined in air by a piezoelectric quartz crystal sensor coated with 4-aminoantipyrine/1-hydroxyetil-2-heptadecenyl imidazol (amine 220) solution (1:1 v/v in chloroform). The analytical response curve is linear over the concentration range from 0.70 to 5.0 ppm of SO{sub 2}. Good linearities (r = 0.9990, 0.9995 and 0.9968) and sensitivities (18.0, 33.4 and 50.7 Hz/ppm) were found, respectively for exposure times of 30, 60 and 90 seconds. The sensor can be used for more than six months without loss in sensitivity and presented good reversibility and reproducibility. Among some possible interferents tested, only nitrogen dioxide and moisture caused major frequency changes.

  20. Effects of interface slip and viscoelasticity on the dynamic response of droplet quartz crystal microbalances.

    Science.gov (United States)

    Zhuang, Han; Lu, Pin; Lim, Siak Piang; Lee, Heow Pueh

    2008-10-01

    In the present paper we first present a derivation based on the time-dependent perturbation theory to develop the dynamical equations which can be applied to model the response of a droplet quartz crystal microbalance (QCM) in contact with a single viscoelastic media. Moreover, the no-slip boundary condition across the device-viscoelastic media interface has been relaxed in the present model by using the Ellis-Hayward slip length approach. The model is then used to illustrate the characteristic changes in the frequency and attenuation of the QCM with and without the boundary slippage due to the changes in viscoelasticity as the coated media varies from Newtonian liquid to solid. To complement the theory, experiments have been conducted with microliter droplets of aqueous glycerol solutions and silicone oils with a viscosity in the range of 50 approximately 10,000 cS. The results have confirmed the Newtonian characteristics of the glycerol solutions. In contrast, the acoustic properties of the silicones oils as reflected in the impedance analysis are different from the glycerol solutions. More importantly, it was found that for the silicone oils the frequency steadily increased for several hours and even exceeded the initial value of the unloaded crystal as reflected in the positive frequency shift. Collaborative effects of interfacial slippage and viscoelasticity have been introduced to qualitatively interpret the measured frequency up-shifts for the silicone oils. The present work shows the potential importance of the combined effects of viscoelasticity and interfacial slippage when using the droplet QCM to investigate the rheological behavior of more complex fluids.

  1. Adsorption Device Based on a Langatate Crystal Microbalance for High Temperature High Pressure Gas Adsorption in Zeolite H-ZSM-5.

    Science.gov (United States)

    Ding, Wenjin; Baracchini, Giulia; Klumpp, Michael; Schwieger, Wilhelm; Dittmeyer, Roland

    2016-08-25

    We present a high-temperature and high-pressure gas adsorption measurement device based on a high-frequency oscillating microbalance (5 MHz langatate crystal microbalance, LCM) and its use for gas adsorption measurements in zeolite H-ZSM-5. Prior to the adsorption measurements, zeolite H-ZSM-5 crystals were synthesized on the gold electrode in the center of the LCM, without covering the connection points of the gold electrodes to the oscillator, by the steam-assisted crystallization (SAC) method, so that the zeolite crystals remain attached to the oscillating microbalance while keeping good electroconductivity of the LCM during the adsorption measurements. Compared to a conventional quartz crystal microbalance (QCM) which is limited to temperatures below 80 °C, the LCM can realize the adsorption measurements in principle at temperatures as high as 200-300 °C (i.e., at or close to the reaction temperature of the target application of one-stage DME synthesis from the synthesis gas), owing to the absence of crystalline-phase transitions up to its melting point (1,470 °C). The system was applied to investigate the adsorption of CO2, H2O, methanol and dimethyl ether (DME), each in the gas phase, on zeolite H-ZSM-5 in the temperature and pressure range of 50-150 °C and 0-18 bar, respectively. The results showed that the adsorption isotherms of these gases in H-ZSM-5 can be well fitted by Langmuir-type adsorption isotherms. Furthermore, the determined adsorption parameters, i.e., adsorption capacities, adsorption enthalpies, and adsorption entropies, compare well to literature data. In this work, the results for CO2 are shown as an example.

  2. Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions.

    Science.gov (United States)

    Arnau, A; García, J V; Jimenez, Y; Ferrari, V; Ferrari, M

    2008-07-01

    A new configuration of automatic capacitance compensation (ACC) technique based on an oscillatorlike working interface, which permits the tracking of the series resonant frequency and the monitoring of the motional resistance and the parallel capacitance of a thickness-shear mode quartz crystal microbalance sensor, is introduced. The new configuration permits an easier calibration of the system which, in principle, improves the accuracy. Experimental results are reported with 9 and 10 MHz crystals in liquids with different parallel capacitances which demonstrate the effectiveness of the capacitance compensation. Some frequency deviations from the exact series resonant frequency, measured by an impedance analyzer, are explained by the specific nonideal behavior of the circuit components. A tentative approach is proposed to solve this problem that is also common to previous ACC systems.

  3. A quartz-crystal-microbalance technique to investigate ion-induced erosion of fusion relevant surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Golczewski, A. [Institut fuer Allgemeine Physik, TU Wien, Wiedner Hauptstr. 8-10/E134, Association EURATOM-OAW, A-1040 Vienna (Austria)], E-mail: golczewski@iap.tuwien.ac.at; Dobes, K.; Wachter, G.; Schmid, M. [Institut fuer Allgemeine Physik, TU Wien, Wiedner Hauptstr. 8-10/E134, Association EURATOM-OAW, A-1040 Vienna (Austria); Aumayr, F. [Institut fuer Allgemeine Physik, TU Wien, Wiedner Hauptstr. 8-10/E134, Association EURATOM-OAW, A-1040 Vienna (Austria)], E-mail: aumayr@iap.tuwien.ac.at

    2009-02-15

    We describe a highly sensitive quartz-crystal-microbalance technique capable of determining erosion as well as implantation and retention rates for fusion relevant surfaces under ion bombardment. Total sputtering yields obtained with this technique for Ar ion impact on polycrystalline gold and tungsten surfaces are presented. The results compare well with existing experimental data as well as theoretical predictions and thus demonstrate the feasibility of the developed technique. Our setup is capable of detecting mass-changes as small as 10{sup -5} {mu}g/s, which corresponds to a removal of only 10{sup -4} W monolayers/s.

  4. Determination of thermodynamic parameters for enolization reaction of malonic and metylmalonic acids by using quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Minoru Yoshimoto

    2016-06-01

    Full Text Available We investigated the process of a bromination reaction of malonic acid and methylmalonic acid in the Belousov-Zhabotinsky reaction by using a quartz crystal microbalance (QCM. The process involves an enolization reaction as a rate-determining step. We found that, in the step, the variation of Br2 concentration induced an exactly quantitative shift of a resonant frequency of the QCM, based on the change of the surface mass on the QCM and the solution viscosity and density. This new finding enabled us to estimate the reaction rate constants and the thermodynamic parameters of the enolization reaction due to a QCM measurement. The values measured by the QCM were in good agreement with those measured by a UV-spectrophotometer. As a result, we succeeded to develop a new measurement method of a nonlinear chemical reaction.

  5. Molecularly Imprinted Quartz Crystal Microbalance Sensor (QCM for Bilirubin Detection

    Directory of Open Access Journals (Sweden)

    Çiğdem Çiçek

    2016-11-01

    Full Text Available This study aims the preparation of a QCM sensor for the detection of bilirubin in human plasma. Bilirubin-imprinted poly-(2-hydroxyethyl methacrylate-N-methacryloyl-l-tryptophan methyl ester (PHEMATrp nanofilm (MIP on the gold surface of a QCM chip was synthesized by the molecular imprinting technique. Meanwhile, the non-imprinted PHEMATrp (NIP nanofilm was synthesized by the same experimental technique to examine the imprinting effect. Characterization of MIP and NIP nanofilms on the QCM chip surface was achieved by atomic force microscopy (AFM, ellipsometry, Fourier transform infrared spectrophotometry-attenuated total reflectance (FTIR-ATR and contact angle measurements (CA. The observations indicated that the nanofilm was almost in a monolayer. Thereinafter, the imprinted and the non-imprinted QCM chips were connected to the QCM system to investigate kinetic and affinity properties. In order to examine the selectivity of the MIP-PHEMATrp nanofilm, competitive adsorption of bilirubin with cholesterol and estradiol was performed. Limit of detection (LOD and limit of quantitation (LOQ values were calculated as 0.45 μg/mL and 0.9 μg/mL, respectively.

  6. Combined optical second harmonic generation/quartz crystal microbalance study of underpotential deposition processes: copper electrodeposition on polycrystalline gold.

    Science.gov (United States)

    Lakkaraju, S; Bennahmias, M J; Borges, G L; Gordon Ii, J G; Lazaga, M; Stone, B M; Ashley, K

    1990-11-20

    Optical second harmonic generation and quartz crystal microbalance techniques are used as in situ probes of copper underpotential deposition on polycrystalline gold surfaces in sulfuric acid electrolyte. The second harmonic signal from a polished bulk gold substrate is observed to decrease by >60% as a result of copper underpotential deposition on gold. Also, the mass of an underpotentially deposited copper adlayer is monitored in situ by an oscillating quartz crystal microbalance, yielding an estimated coverage of ~8.0 x 10(-10) mol cm(-2) and an electrosorption valency of 1.5 for a copper adlayer on the surface of vapor-deposited polycrystalline gold.

  7. Electroacoustic polymer microchip as an alternative to quartz crystal microbalance for biosensor development.

    Science.gov (United States)

    Gamby, Jean; Lazerges, Mathieu; Girault, Hubert H; Deslouis, Claude; Gabrielli, Claude; Perrot, Hubert; Tribollet, Bernard

    2008-12-01

    Laser photoablation of poly(ethylene terephthalate) (PET), a flexible dielectric organic polymer, was used to design an acoustic miniaturized DNA biosensor. The microchip device includes a 100-microm-thick PET layer, with two microband electrodes patterned in photoablated microchannels on one side and a depressed photoablated disk decorated by gold sputtered layer on the other side. Upon application of an electric signal between the two electrodes, an electroacoustic resonance phenomenon at approximately 30 MHz was established through the microelectrodes/PET/ gold layer interface. The electroacoustic resonance response was fitted with a series RLC motional arm in parallel with a static Co arm of a Buttlerworth-Van Dyke equivalent circuit: admittance spectra recorded after successive cycles of DNA hybridization on the gold surface showed reproducible changes on R, L, and C parameters. The same hybridizations runs were performed concomitantly on a 27-MHz (9 MHz, third overtone) quartz crystal microbalance in order to validate the PET device developed for bioanalysis applications. The electroacoustic PET device, approximately 100 times smaller than a microbalance quartz crystal, is interesting for the large-scale integration of acoustic sensors in biochips.

  8. The use of quartz crystal microbalance with dissipation (QCM-D for studying nanoparticle-induced platelet aggregation

    Directory of Open Access Journals (Sweden)

    Santos-Martinez MJ

    2012-01-01

    Full Text Available Maria Jose Santos-Martinez1–3, Iwona Inkielewicz-Stepniak1,4, Carlos Medina1, Kamil Rahme5,6, Deirdre M D'Arcy1, Daniel Fox3, Justin D Holmes3,5, Hongzhou Zhang3, Marek Witold Radomski3,51School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, 3Center for Research on Adaptive Nanostructures and Nanodevices, Trinity College Dublin, Dublin, Ireland; 4Department of Medicinal Chemistry, Medical University of Gdansk, Gdansk, Poland; 5Materials and Supercritical Fluids Group, Department of Chemistry and the Tyndall National Institute, University College Cork, Cork, Ireland; 6Department of Sciences, Faculty of Natural and Applied Science, Notre Dame University, Zouk Mosbeh, LebanonAbstract: Interactions between blood platelets and nanoparticles have both pharmacological and toxicological significance and may lead to platelet activation and aggregation. Platelet aggregation is usually studied using light aggregometer that neither mimics the conditions found in human microvasculature nor detects microaggregates. A new method for the measurement of platelet microaggregation under flow conditions using a commercially available quartz crystal microbalance with dissipation (QCM-D has recently been developed. The aim of the current study was to investigate if QCM-D could be used for the measurement of nanoparticle-platelet interactions. Silica, polystyrene, and gold nanoparticles were tested. The interactions were also studied using light aggregometry and flow cytometry, which measured surface abundance of platelet receptors. Platelet activation was imaged using phase contrast and scanning helium ion microscopy. QCM-D was able to measure nanoparticle-induced platelet microaggregation for all nanoparticles tested at concentrations that were undetectable by light aggregometry and flow cytometry. Microaggregates were measured by changes in frequency and dissipation, and the presence of platelets on the sensor surface was confirmed and imaged by

  9. Sugar nanowires based on cyclodextrin on quartz crystal microbalance for gas sensing with ultra-high sensitivity

    Science.gov (United States)

    Asano, Atsushi; Maeyoshi, Yuta; Watanabe, Shogo; Saeki, Akinori; Sugimoto, Masaki; Yoshikawa, Masahito; Nanto, Hidehito; Tsukuda, Satoshi; Tanaka, Shun-Ichiro; Seki, Shu

    2013-03-01

    Cyclodextrins (CDs), hosting selectively a wide range of guest molecules in their hydrophobic cavity, were directly fabricated into 1-dimensional nanostructures with extremely wide surface area by single particle nanofabrication technique in the present paper. The copolymers of acrylamide and mono(6-allyl)-β-CD were synthesized, and the crosslinking reaction of the polymer alloys with poly(4-bromostyrene) (PBrS) in SPNT gave nanowires on the quarts substrate with high number density of 5×109 cm-2. Quartz crystal microbalance (QCM) measurement suggested 320 fold high sensitivity for formic acid vapor adsorption in the nanowire fabricated surfaces compared with that in the thin solid film of PBrS, due to the incorporation of CD units and extremely wide surface area of the nanowires.

  10. Preparation of new molecularly imprinted quartz crystal microbalance hybride sensor system for 8-hydroxy-2'-deoxyguanosine determination.

    Science.gov (United States)

    Say, Ridvan; Gültekin, Aytaç; Ozcan, Ayça Atilir; Denizli, Adil; Ersöz, Arzu

    2009-04-27

    The routine measurement of 8-hydroxy-2'-deoxyguanosine (8-OHdG) in biological samples is a difficult analytical problem due to the low levels of the analyte and complex matrix. A new 8-OHdG imprinted quartz crystal microbalance (QCM) sensor has been developed for selective determination of 8-OHdG in serum samples. To fulfil the desired results, we have used methacryloyl aminoantipyrine-Fe(III) [MAAP-Fe(III)] and methacryloyl histidine-Pt(II) [MAH-Pt(II)] as metal-chelating monomers via double metal coordination-chelation interactions for the preparation of additional selective molecular imprinted polymers (MIP). The study includes the measurement of binding interaction of 8-OHdG imprinted quartz crystal microbalance (QCM) sensor, selectivity experiments and analytical performance of QCM chip. The obtained results have showed that the application of double metal-chelate monomer systems has been more effective than single metal-chelate monomer systems. In this study, the detection limit and the linear working range were found to be 0.0075 and 0.0100-3.5 microM, respectively. The affinity constant (K(affinity)) was found to be 1.54x10(5) M(-1) for 8-OHdG using MAH-Pt-8-OHdG-MAAP-Fe based thin film. Also, selectivity of prepared QCM sensor was found as being very high in the presence of competitive species. At the last step of this procedure, 8-OHdG level in blood serum which belongs to a intestinal cancer patient was determined by the prepared QCM sensor.

  11. Quartz Crystal Microbalance Investigation of the Structure of Adsorbed Soybean Oil and Methyl Oleate onto Steel Surface

    Science.gov (United States)

    The adsorption of soybean oil (SBO) and methyl oleate (MO) onto steel was investigated using quartz crystal microbalance with dissipation monitoring (QCM-D). Adsorption of both SBO and MO increased with increasing concentrations. At full surface coverage, SBO and MO formed rigid thin films and ach...

  12. In-situ monitoring of potential enhanced DNA related processes using electrochemical quartz crystal microbalance with dissipation (EQCM-D)

    DEFF Research Database (Denmark)

    Quan, Xueling; Heiskanen, Arto; Tenje, Maria

    2014-01-01

    The effect of applied potential pulses on DNA functionalization (thiolated single stranded DNA) and hybridization processes has been monitored in-situ on gold surfaces using electrochemical quartz crystal microbalance with dissipation (EQCM-D). The applied potentials were chosen with respect to t...

  13. Pharmacological characterization of nanoparticle-induced platelet microaggregation using quartz crystal microbalance with dissipation: comparison with light aggregometry

    Science.gov (United States)

    Santos-Martinez, Maria J; Tomaszewski, Krzysztof A; Medina, Carlos; Bazou, Despina; Gilmer, John F; Radomski, Marek W

    2015-01-01

    Background Engineered nanoparticles (NPs) can induce platelet activation and aggregation, but the mechanisms underlying these interactions are not well understood. This could be due in part to use of devices that study platelet function under quasi-static conditions with low sensitivity to measure platelet microaggregation. Therefore, in this study we investigated the pharmacological pathways and regulators of NP-induced platelet microaggregation under flow conditions at nanoscale using quartz crystal microbalance with dissipation (QCM-D) and compared the data thus obtained with those generated by light aggregometry. Methods Blood was collected from healthy volunteers, and platelet-rich plasma was obtained. Thrombin receptor-activating peptide, a potent stimulator of platelet function, and pharmacological inhibitors were used to modulate platelet microaggregation in the presence/absence of silica (10 nm and 50 nm) and polystyrene (23 nm) NPs. Light aggregometry was used to study platelet aggregation in macroscale. Optical, immunofluorescence, and scanning electron microscopy were also used to visualize platelet aggregates. Results Platelet microaggregation was enhanced by thrombin receptor-activating peptide, whereas prostacyclin, nitric oxide donors, acetylsalicylic acid, and phenanthroline, but not adenosine diphosphate (ADP) blockers, were able to inhibit platelet microaggregation. NPs caused platelet microaggregation, an effect not detectable by light aggregometry. NP-induced microaggregation was attenuated by platelet inhibitors. Conclusion NP-induced platelet microaggregation appears to involve classical proaggregatory pathways (thromboxane A2-mediated and matrix metalloproteinase-2-mediated) and can be regulated by endogenous (prostacyclin) and pharmacological (acetylsalicylic acid, phenanthroline, and nitric oxide donors) inhibitors of platelet function. Quartz crystal microbalance with dissipation, but not light aggregometry, is an appropriate method for

  14. Development of 170 MHz Electrodeless Quartz-Crystal Microbalance Immunosensor with Nonspecifically Immobilized Receptor Proteins

    Science.gov (United States)

    Ogi, Hirotsugu; Nagai, Hironao; Fukunishi, Yuji; Yanagida, Taiji; Hirao, Masahiko; Nishiyama, Masayoshi

    2010-07-01

    Staphylococcus aureus protein A (SPA) shows high nonspecific binding affinity on a naked quartz surface, and it can be used as the receptor protein for detecting immunoglobulin G (IgG), the most important immunoglobulin. The immunosensor ability, however, significantly depends on the immobilization procedure. In this work, the effect of the nonspecific immobilization procedure on the sensor sensitivity is studied using a home-built electrodeless quartz-crystal microbalance (QCM) biosensor. The pure-shear vibration of a 9.7-µm-thick AT-cut quartz plate is excited and detected in liquids by the line antenna located outside the flow channel. SPA molecules are immobilized on the quartz surfaces, and human IgG is injected to monitor the binding reaction between SPA and IgG. This study reveals that a long (nearly 24 h) immersion procedure is required for immobilizing SPA to achieve the tight biding with the quartz surfaces.

  15. Optimization of the hybrid bilayer membrane method for immobilization of avidin on quartz crystal microbalance.

    Science.gov (United States)

    Mun, Saem; Choi, Suk-Jung

    2009-04-15

    Hybrid bilayer membrane (HBM), comprising a lipid monolayer fused to a hydrophobic self-assembled monolayer (SAM), has a potential capability to provide a convenient tool for the preparation of functionalized sensor surfaces. In this work, the HBM approach was optimized for the preparation of avidin-containing quartz crystal microbalance (QCM) sensor chip which would be available for immobilization of biotinylated molecules. Lipid layer of HBM was composed of background lipid such as egg phosphatidyl choline and biotinylated lipid to which avidin was attached. Highest performance was obtained at 1:1 ratio of the biotinylated lipid and the background lipid, and sensitivity and stability of the resulting sensor chip was comparable to a sensor chip prepared by the conventional carbodiimide reaction. By utilizing the HBM method, construction of a stable avidin sensor chip was achieved within 40 min without any chemical steps. Thus the HBM method was proven to be a convenient and efficient way to immobilize avidin on sensor surfaces.

  16. New Approach to a Practical Quartz Crystal Microbalance Sensor Utilizing an Inkjet Printing System

    Directory of Open Access Journals (Sweden)

    Yusuke Fuchiwaki

    2014-10-01

    Full Text Available The present work demonstrates a valuable approach to developing quartz crystal microbalance (QCM sensor units inexpensively for reliable determination of analytes. This QCM sensor unit is constructed by inkjet printing equipment utilizing background noise removal techniques. Inkjet printing equipment was chosen as an alternative to an injection pump in conventional flow-mode systems to facilitate the commercial applicability of these practical devices. The results demonstrate minimization of fluctuations from external influences, determination of antigen-antibody interactions in an inkjet deposition, and quantification of C-reactive protein in the range of 50–1000 ng∙mL−1. We thus demonstrate a marketable application of an inexpensive and easily available QCM sensor system.

  17. A highly sensitive humidity sensor based on a nanofibrous membrane coated quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xianfeng; Ding Bin [State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620 (China); Yu Jianyong [Nanomaterials Research Center, Modern Textile Institute, Donghua University, Shanghai 200051 (China); Wang, Moran [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Pan Fukui, E-mail: binding@dhu.edu.cn [College of Textiles and Fashion, Qingdao University, Qingdao 266071 (China)

    2010-02-05

    A novel humidity sensor was fabricated by electrospinning deposition of nanofibrous polyelectrolyte membranes as sensitive coatings on a quartz crystal microbalance (QCM). The results of sensing experiments indicated that the response of the sensors increased by more than two orders of magnitude with increasing relative humidity (RH) from 6 to 95% at room temperature, exhibiting high sensitivity, and that, in the range of 20-95% RH, the Log({Delta}f) showed good linearity. The sensitivity of fibrous composite polyacrylic acid (PAA)/poly(vinyl alcohol) (PVA) membranes was two times higher than that of the corresponding flat films at 95% RH. Compared with fibrous PAA/PVA membranes, the nanofibrous PAA membranes exhibited remarkably enhanced humidity sensitivity due to their high PAA content and large specific surface area caused by the formation of ultrathin nanowebs among electrospun fibers. Additionally, the resultant sensors exhibited a good reversible behavior and good long term stability.

  18. A highly sensitive humidity sensor based on a nanofibrous membrane coated quartz crystal microbalance

    Science.gov (United States)

    Wang, Xianfeng; Ding, Bin; Yu, Jianyong; Wang, Moran; Pan, Fukui

    2010-02-01

    A novel humidity sensor was fabricated by electrospinning deposition of nanofibrous polyelectrolyte membranes as sensitive coatings on a quartz crystal microbalance (QCM). The results of sensing experiments indicated that the response of the sensors increased by more than two orders of magnitude with increasing relative humidity (RH) from 6 to 95% at room temperature, exhibiting high sensitivity, and that, in the range of 20-95% RH, the Log(Δf) showed good linearity. The sensitivity of fibrous composite polyacrylic acid (PAA)/poly(vinyl alcohol) (PVA) membranes was two times higher than that of the corresponding flat films at 95% RH. Compared with fibrous PAA/PVA membranes, the nanofibrous PAA membranes exhibited remarkably enhanced humidity sensitivity due to their high PAA content and large specific surface area caused by the formation of ultrathin nanowebs among electrospun fibers. Additionally, the resultant sensors exhibited a good reversible behavior and good long term stability.

  19. Quartz-Crystal Microbalance (QCM) for Public Health: An Overview of Its Applications.

    Science.gov (United States)

    Bragazzi, Nicola Luigi; Amicizia, Daniela; Panatto, Donatella; Tramalloni, Daniela; Valle, Ivana; Gasparini, Roberto

    2015-01-01

    Nanobiotechnologies, from the convergence of nanotechnology and molecular biology and postgenomics medicine, play a major role in the field of public health. This overview summarizes the potentiality of piezoelectric sensors, and in particular, of quartz-crystal microbalance (QCM), a physical nanogram-sensitive device. QCM enables the rapid, real time, on-site detection of pathogens with an enormous burden in public health, such as influenza and other respiratory viruses, hepatitis B virus (HBV), and drug-resistant bacteria, among others. Further, it allows to detect food allergens, food-borne pathogens, such as Escherichia coli and Salmonella typhimurium, and food chemical contaminants, as well as water-borne microorganisms and environmental contaminants. Moreover, QCM holds promises in early cancer detection and screening of new antiblastic drugs. Applications for monitoring biohazards, for assuring homeland security, and preventing bioterrorism are also discussed.

  20. Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

    Science.gov (United States)

    Bechtold, Mary M.

    1995-01-01

    When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings

  1. Detection of label-free cancer biomarkers using nickel nanoislands and quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Adrián Martínez-Rivas

    2010-09-01

    Full Text Available Adrián Martínez-Rivas1,2, Patrick Chinestra3,4, Gilles Favre3,4, Sébastien Pinaud1, Childérick Séverac1,2, Jean-Charles Faye3,4, Christophe Vieu1,21LAAS-CNRS; Université de Toulouse, Toulouse, France; 2Université de Toulouse, UPS, INSA, INP, ISAE; LAAS; Toulouse, France; 3INSERM U563, Université de Toulouse, CPTP, “Signalisation Cellulaire, GTPase Rho et cancers”, Toulouse, France; 4Institut Claudius Regaud, Biology Department, Toulouse, FranceAbstract: We present a technique for the label-free detection and recognition of cancer biomarkers using metal nanoislands intended to be integrated in a novel type of nanobiosensor. His-tagged (scFv-F7N1N2 is the antibody fragment which is directly immobilized, by coordinative bonds, onto ~5 nm nickel islands, then deposited on the surface of a quartz crystal of a quartz crystal microbalance (QCM to validate the technique. Biomarker GTPase RhoA was investigated because it has been found to be overexpressed in various tumors and because we have recently isolated and characterized a new conformational scFv which selectively recognizes the active form of RhoA. We implemented a surface chemistry involving an antibiofouling coating of polyethylene glycol silane (PEG-silane (<2 nm thick and Ni nanoislands to reach a label-free detection of the active antigen conformation of RhoA, at various concentrations. The methodology proposed here proves the viability of the concept by using Ni nanoislands as an anchoring surface layer enabling the detection of a specific conformation of a protein, identified as a potential cancer biomarker. Hence, this novel methodology can be transferred to a nanobiosensor to detect, at lower time consumption and with high sensitivity, specific biomolecules.Keywords: nickel nanoislands, cancer biomarkers, quartz crystal microbalance, PEG-silane, RhoA protein, nanobiosensor

  2. Label-free real-time acoustic sensing of microvesicle release from prostate cancer (PC3) cells using a Quartz Crystal Microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, Dan [Cellular and Molecular Immunology Research Centre, School of Human Sciences, London Metropolitan University, London (United Kingdom); Lange, Sigrun [University College London School of Pharmacy, 29-39 Brunswick Square, London WC1N 1AX (United Kingdom); Kholia, Sharad; Jorfi, Samireh; Antwi-Baffour, Samuel [Cellular and Molecular Immunology Research Centre, School of Human Sciences, London Metropolitan University, London (United Kingdom); Inal, Jameel, E-mail: j.inal@londonmet.ac.uk [Cellular and Molecular Immunology Research Centre, School of Human Sciences, London Metropolitan University, London (United Kingdom)

    2014-10-24

    Highlights: • Microvesiculating cells record loss of mass on a Quartz Crystal Microbalance. • Using the Quartz Crystal Microbalance microvesicles are measured at 0.24 pg. • The QCM-D reveals loss in viscoelastic properties in microvesiculating cells. - Abstract: Using a Quartz Crystal Microbalance with dissipation monitoring, QCM-D (label-free system) measuring changes in resonant frequency (Δf) that equate to mass deposited on a sensor, we showed the attachment, over a 60 min period, of a monolayer of PC3 cells to the gold electrodes of the quartz crystal sensor, which had been rendered hydrophilic. That MVs were released upon BzATP stimulation of cells was confirmed by NTA analysis (average 250 nm diameter), flow cytometry, showing high phosphatidylserine exposition and by fluorescent (Annexin V Alexa Fluor® 488-positive) and electron microscopy. Over a period of 1000s (16.7 min) during which early apoptosis increased from 4% plateauing at 10% and late apoptosis rose to 2%, the Δf increased 20 Hz, thereupon remaining constant for the last 1000s of the experiment. Using the Sauerbrey equation, the loss in mass, which corresponded to the release of 2.36 × 10{sup 6} MVs, was calculated to be 23 ng. We therefore estimated the mass of an MV to be 0.24 pg. With the deposition on the QCM-D of 3.5 × 10{sup 7} MVs over 200s, the decrease in Δf (Hz) gave an estimate of 0.235 pg per MV.

  3. Lectin typing of Campylobacter jejuni using a novel quartz crystal microbalance technique

    Energy Technology Data Exchange (ETDEWEB)

    Yakovleva, Maria E., E-mail: maria.yakovleva@gmail.com [Department of Infectious Diseases and Medical Microbiology, Lund University, 223 62 Lund (Sweden); Moran, Anthony P. [Department of Microbiology, School of Natural Sciences, National University of Ireland, Galway (Ireland); Safina, Gulnara R. [Department of Analytical and Marine Chemistry, University of Gothenburg, 412 96 Gothenburg (Sweden); Wadstroem, Torkel [Department of Infectious Diseases and Medical Microbiology, Lund University, 223 62 Lund (Sweden); Danielsson, Bengt [Acromed Invest AB, Magistratsvaegen 10, 226 43 Lund (Sweden)

    2011-05-23

    Seven Campylobacter jejuni strains were characterised by a lectin typing assay. The typing system was based on a quartz crystal microbalance technique (QCM) with four commercially available lectins (wheat germ agglutinin, Maackia amurensis lectin, Lens culinaris agglutinin, and Concanavalin A), which were chosen for their differing carbohydrate specificities. Initially, the gold surfaces of the quartz crystals were modified with 11-mercaptoundecanoic acid followed by lectin immobilisation using a conventional amine-coupling technique. Bacterial cells were applied for lectin typing without preliminary treatment, and resonant frequency and dissipation responses were recorded. The adhesion of microorganisms on lectin surfaces was confirmed by atomic force microscopy. Scanning was performed in the tapping mode and the presence of bacteria on lectin-coated surfaces was successfully demonstrated. A significant difference in the dissipation response was observed for different C. jejuni strains which made it possible to use this parameter for discriminating between bacterial strains. In summary, the QCM technique proved a powerful tool for the recognition and discrimination of C. jejuni strains. The approach may also prove applicable to strain discrimination of other bacterial species, particularly pathogens.

  4. Detection of label-free cancer biomarkers using nickel nanoislands and quartz crystal microbalance.

    Science.gov (United States)

    Martínez-Rivas, Adrián; Chinestra, Patrick; Favre, Gilles; Pinaud, Sébastien; Séverac, Childérick; Faye, Jean-Charles; Vieu, Christophe

    2010-09-07

    We present a technique for the label-free detection and recognition of cancer biomarkers using metal nanoislands intended to be integrated in a novel type of nanobiosensor. His-tagged (scFv)-F7N1N2 is the antibody fragment which is directly immobilized, by coordinative bonds, onto ~5 nm nickel islands, then deposited on the surface of a quartz crystal of a quartz crystal microbalance (QCM) to validate the technique. Biomarker GTPase RhoA was investigated because it has been found to be overexpressed in various tumors and because we have recently isolated and characterized a new conformational scFv which selectively recognizes the active form of RhoA. We implemented a surface chemistry involving an antibiofouling coating of polyethylene glycol silane (PEG-silane) (<2 nm thick) and Ni nanoislands to reach a label-free detection of the active antigen conformation of RhoA, at various concentrations. The methodology proposed here proves the viability of the concept by using Ni nanoislands as an anchoring surface layer enabling the detection of a specific conformation of a protein, identified as a potential cancer biomarker. Hence, this novel methodology can be transferred to a nanobiosensor to detect, at lower time consumption and with high sensitivity, specific biomolecules.

  5. A quartz crystal microbalance sensor based on mussel-inspired molecularly imprinted polymer.

    Science.gov (United States)

    Zhou, Wen-Hui; Tang, Shui-Fen; Yao, Qiu-Hong; Chen, Fa-Rong; Yang, Huang-Hao; Wang, Xiao-Ru

    2010-10-15

    In this work, we describe a simple, inexpensive and fast method for the generation of molecularly imprinted polymer (MIP) film on quartz crystal microbalance (QCM) crystals using mussel-inspired polymer. Commonly known as a neurotransmitter, dopamine is also a small-molecule mimic of the adhesive proteins of mussels. Polymerization of dopamine in the presence of template molecule (1,3,5-pentanetricarboxylic acid, an analogue of domoic acid, in this case) could produce an adherent molecularly imprinted polydopamine film coating on QCM crystals. Advantages, such as high hydrophilicity, high biocompatibility and controllable thickness, make this molecularly imprinted polydopamine film an attractive recognition element for sensors. Selective rebinding of domoic acid on mussel-inspired molecularly imprinted polymer (m-MIP) coated crystal was observed as a frequency shift quantified by piezoelectric microgravimetry with the QCM system. The decreasing frequency shows a good linear relationship with the concentration of domoic acid. The quantitation limit of domoic acid was 5 ppb with the linear range of 0-100 ppb. The QCM sensor has high selectivity and was able to distinguish domoic acid from its analogous p-phthalic acid and o-phthalic acid owing to the molecular imprinting effect. In addition, the practical analytical performance of the sensor was examined by evaluating the detection of domoic acid in mussel extracts with satisfactory results. It is envisaged that m-MIP could be suitable as recognition element for sensors and the proposed m-MIP QCM sensor could be employed to detect analyte of interest in complex matrices. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. The use of quartz crystal microbalance with dissipation (QCM-D) for studying nanoparticle-induced platelet aggregation

    Science.gov (United States)

    Santos-Martinez, Maria Jose; Inkielewicz-Stepniak, Iwona; Medina, Carlos; Rahme, Kamil; D’Arcy, Deirdre M; Fox, Daniel; Holmes, Justin D; Zhang, Hongzhou; Radomski, Marek Witold

    2012-01-01

    Interactions between blood platelets and nanoparticles have both pharmacological and toxicological significance and may lead to platelet activation and aggregation. Platelet aggregation is usually studied using light aggregometer that neither mimics the conditions found in human microvasculature nor detects microaggregates. A new method for the measurement of platelet microaggregation under flow conditions using a commercially available quartz crystal microbalance with dissipation (QCM-D) has recently been developed. The aim of the current study was to investigate if QCM-D could be used for the measurement of nanoparticle-platelet interactions. Silica, polystyrene, and gold nanoparticles were tested. The interactions were also studied using light aggregometry and flow cytometry, which measured surface abundance of platelet receptors. Platelet activation was imaged using phase contrast and scanning helium ion microscopy. QCM-D was able to measure nanoparticle-induced platelet microaggregation for all nanoparticles tested at concentrations that were undetectable by light aggregometry and flow cytometry. Microaggregates were measured by changes in frequency and dissipation, and the presence of platelets on the sensor surface was confirmed and imaged by phase contrast and scanning helium ion microscopy. PMID:22275839

  7. Superior environment resistance of quartz crystal microbalance with anatase TiO{sub 2}/ZnO nanorod composite films

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Wei, E-mail: weiqiang.tju@163.com [Tianjin Key Laboratory of Composite and Functional Materials, School of Materials Science and Engineering, Tianjin University, 92 Weijin Road, Tianjin (China); Wei, Li; Shaodan, Wang [Tianjin Key Laboratory of Composite and Functional Materials, School of Materials Science and Engineering, Tianjin University, 92 Weijin Road, Tianjin (China); Yu, Bai [Beijing Institute of Spacecrafts Environment Engineering, Beijing 100094 (China)

    2015-08-30

    Graphical abstract: ZnO nanorod array being prepared by an in situ method on the QCM coated with Au film via hydrothermal process and surface modification with coated TiO{sub 2} by sol–gel methods to form a superhydrophobic TiO{sub 2}/ZnO composite film the anatase TiO{sub 2}/ZnO nanorod composite film with a sharp, pencil-like structure exhibiting excellent superhydrophobicity (water contact angle of 155°), non-sticking water properties, and an autonomous cleaning property under UV irradiation. The anatase TiO{sub 2}/ZnO nanorod composite film facilitates the precise measurement and extended lifetime of the QCM for the detection of organic gas molecules. - Highlights: • This work combines, for the first time, the advantage of the TiO{sub 2}/ZnO composite film on photocatalysis and reversible super-hydrophobic and super-hydrophilic transition, and puts forward a solution to satisfy weatherability of quartz crystal microbalance in long-term application. • The anatase TiO{sub 2}/ZnO nanorod composite film with pencil structure exhibit excellent super-hydrophobicity (water contact angle can reach 155°), no-sticking water properties and self-cleaning property under UV irradiation. • The photocatalysis and reversible super-hydrophobic and super-hydrophilic transition of the TiO{sub 2}/ZnO nanorod composite film is stable in long-term application. - Abstract: The precise measurement of quartz crystal microbalance (QCM) in the detection and weighing of organic gas molecules is achieved due to excellent superhydrophobicity of a deposited film composite. Photocatalysis is utilized as a method for the self-cleaning of organic molecules on the QCM for extended long-term stability in the precision of the instrument. In this paper, ZnO nanorod array is prepared via in situ methods on the QCM coated with Au film via hydrothermal process. Subsequently, a TiO{sub 2}/ZnO composite film is synthesized by surface modification with TiO{sub 2} via sol–gel methods. Results

  8. Adsorption Analysis of Lactoferrin to Titanium, Stainless Steel, Zirconia, and Polymethyl Methacrylate Using the Quartz Crystal Microbalance Method

    Directory of Open Access Journals (Sweden)

    Eiji Yoshida

    2016-01-01

    Full Text Available It is postulated that biofilm formation in the oral cavity causes some oral diseases. Lactoferrin is an antibacterial protein in saliva and an important defense factor against biofilm development. We analyzed the adsorbed amount of lactoferrin and the dissociation constant (Kd of lactoferrin to the surface of different dental materials using an equilibrium analysis technique in a 27 MHz quartz crystal microbalance (QCM measurement. Four different materials, titanium (Ti, stainless steel (SUS, zirconia (ZrO2 and polymethyl methacrylate (PMMA, were evaluated. These materials were coated onto QCM sensors and the surfaces characterized by atomic force microscopic observation, measurements of surface roughness, contact angles of water, and zeta potential. QCM measurements revealed that Ti and SUS showed a greater amount of lactoferrin adsorption than ZrO2 and PMMA. Surface roughness and zeta potential influenced the lactoferrin adsorption. On the contrary, the Kd value analysis indicated that the adsorbed lactoferrin bound less tightly to the Ti and SUS surfaces than to the ZrO2 and PMMA surfaces. The hydrophobic interaction between lactoferrin and ZrO2 and PMMA is presumed to participate in better binding of lactoferrin to ZrO2 and PMMA surfaces. It was revealed that lactoferrin adsorption behavior was influenced by the characteristics of the material surface.

  9. Determination of functionalized gold nanoparticles incorporated in hydrophilic and hydrophobic microenvironments by surface modification of quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tsui-Hsun [Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC (China); Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan, ROC (China); Liao, Shu-Chuan [Center of Thin Film Technologies and Applications, Mingchi University of Technology, Taipei, Taiwan, ROC (China); Chen, Ying-Fang [Department of Dentistry, Yun-Lin Branch, National Taiwan University Hospital, Dou-Liu, Yun-Lin, Taiwan, ROC (China); Huang, Yi-You [Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC (China); Wei, Yi-Syuan [Department of Materials Engineering, Tatung University, 40 Zhongshan North Road, 3rd Section, Taipei 104, Taiwan, ROC (China); Tu, Shu-Ju, E-mail: sjt@cgu.edu.tw [Department of Medical Imaging and Radiological Sciences, Chang Gung University, 259 Wen-Hwa, 1st Road, Kwei-Shan, Tao-Yuan 133, Taiwan, ROC (China); Chen, Ko-Shao, E-mail: kschen@ttu.edu.tw [Department of Materials Engineering, Tatung University, 40 Zhongshan North Road, 3rd Section, Taipei 104, Taiwan, ROC (China)

    2013-06-01

    In this study, plasma deposition methods were used to immobilize Au electrode of a quartz crystal microbalance (QCM) to create different microenvironments for mass measurement of various modified Au nanoparticles (AuNPs). AuNPs were modified by 11-mercaptoundecanoic acid (MUA) and 1-decanethiol (DCT) for potential applications to drug release, protective coatings, and immunosensors. We aimed to develop a highly sensitive and reliable method to quantify the mass of various modified AuNPs. The surface of AuNPs and Au electrode was coated with polymer films, as determined by Fourier transform infrared spectroscopy and atomic force microscopy. Measurements obtained for various AuNPs and the plasma-treated surface of the Au electrode were compared with those obtained for an untreated Au electrode. According to the resonant frequency shift of QCM, a linear relationship was observed that significantly differed for AuNPs, MUA-AuNPs, and DCT-AuNPs (R{sup 2} range, 0.94–0.965, 0.934–0.972, and 0.874–0.9514, respectively). Compared to inductively coupled plasma and micro-computerized tomography, the QCM method with plasma treatment has advantages of real-time monitoring, greater sensitivity, and lower cost. Our results demonstrate that surface modifications measured by a QCM system for various modified AuNPs were reliable.

  10. Rancang Bangun Sistem Pencacah Frekuensi Untuk Sensor Gas Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Brilianda Adi Wicaksono

    2014-03-01

    Full Text Available Dalam suatu sistem identifikasi gas menggunakan sensor Quartz Crystal Microbalance (QCM diperlukan sebuah pencacah frekuensi yang digunakan untuk menghitung perubahan frekuensi dari sensor. Sistem ini digunakan untuk menghasilkan output berupa perubahan frekuensi yang akan diproses untuk identifikasi gas. Metode ini menggunakan selisih antara frekuensi sensor QCM dan frekuensi referensi. Hasil dari selisih tersebut dibagi dan digunakan untuk mengaktifkan pencacah frekuensi. Semakin besar bilangan pembagi, maka sistem pencacah frekuensi ini semakin stabil dan akurat. Penelitian ini menggunakan kristal referensi 20MHz dengan pencacah frekuensi 24 bit. Data hasil pencacahan diakuisisi oleh mikrokontroler dan dikirim ke komputer untuk proses identifikasi menggunakan neural network. Output dari neural network ini merupakan hasil dari proses identifikasi gas. Dengan metode yang digunakan, perubahan frekuensi yang dapat dideteksi mencapai 0,068 Hz. Dalam pengujian keseluruhan sistem digunakan 3 bahan uji, yaitu alkohol, amoniak, dan asam asetat (cuka.Untuk sistem identifikasi gas telah dapat mengenali gas uji dengan keberhasilan 90%. Secara keseluruhan, metode ini diharapkan menjadi metode yang baik untuk sistem identifikasi gas.

  11. Biomimetic Receptors for Bioanalyte Detection by Quartz Crystal Microbalances — From Molecules to Cells

    Directory of Open Access Journals (Sweden)

    Usman Latif

    2014-12-01

    Full Text Available A universal label-free detection of bioanalytes can be performed with biomimetic quartz crystal microbalance (QCM coatings prepared by imprinting strategies. Bulk imprinting was used to detect the endocrine disrupting chemicals (EDCs known as estradiols. The estrogen 17β-estradiol is one of the most potent EDCs, even at very low concentrations. A highly sensitive, selective and robust QCM sensor was fabricated for real time monitoring of 17β-estradiol in water samples by using molecular imprinted polyurethane. Optimization of porogen (pyrene and cross-linker (phloroglucinol levels leads to improved sensitivity, selectivity and response time of the estradiol sensor. Surface imprinting of polyurethane as sensor coating also allowed us to generate interaction sites for the selective recognition of bacteria, even in a very complex mixture of interfering compounds, while they were growing from their spores in nutrient solution. A double molecular imprinting approach was followed to transfer the geometrical features of natural bacteria onto the synthetic polymer to generate biomimetic bacteria. The use of biomimetic bacteria as template makes it possible to prepare multiple sensor coatings with similar sensitivity and selectivity. Thus, cell typing, e.g., differentiation of bacteria strains, bacteria growth profile and extent of their nutrition, can be monitored by biomimetic mass sensors. Obviously, this leads to controlled cell growth in bioreactors.

  12. Quartz Crystal Microbalance Studies of Multilayer Glucagon Fibrillation at the Solid-Liquid Interface

    Science.gov (United States)

    Hovgaard, Mads Bruun; Dong, Mingdong; Otzen, Daniel Erik; Besenbacher, Flemming

    2007-01-01

    We have used a quartz crystal microbalance with dissipation (QCM-D) to monitor the changes in layer thickness and viscoelastic properties accompanying multilayer amyloid deposition in situ for the first time. By means of atomic force microscope imaging, an unequivocal correlation is established between the interfacial nucleation and growth of glucagon fibrils and the QCM-D response. The combination of the two techniques allows us to study the temporal evolution of the interfacial fibrillation process. We have modeled the QCM-D data using an extension to the Kelvin-Voigt viscoelastic model. Three phases were observed in the fibrillation process: 1), a rigid multilayer of glucagon monomers forms and slowly rearranges; 2), this multilayer subsequently evolves into a dramatically more viscoelastic layer, containing a polymorphic network of micrometer-long fibrils growing from multiple nucleation sites; and 3), the fibrillar formation effectively stops as a result of the depletion of bulk-phase monomers, although the process can be continued without a lag phase by subsequent addition of fresh monomers. The robustness of the QCM-D technique, consolidated by complementary atomic force microscope studies, should make it possible to combine different components thought to be involved in the plaque formation process and thus build up realistic models of amyloid plaque formation in vitro. PMID:17513349

  13. Quartz crystal microbalance studies of multilayer glucagon fibrillation at the solid-liquid interface.

    Science.gov (United States)

    Hovgaard, Mads Bruun; Dong, Mingdong; Otzen, Daniel Erik; Besenbacher, Flemming

    2007-09-15

    We have used a quartz crystal microbalance with dissipation (QCM-D) to monitor the changes in layer thickness and viscoelastic properties accompanying multilayer amyloid deposition in situ for the first time. By means of atomic force microscope imaging, an unequivocal correlation is established between the interfacial nucleation and growth of glucagon fibrils and the QCM-D response. The combination of the two techniques allows us to study the temporal evolution of the interfacial fibrillation process. We have modeled the QCM-D data using an extension to the Kelvin-Voigt viscoelastic model. Three phases were observed in the fibrillation process: 1), a rigid multilayer of glucagon monomers forms and slowly rearranges; 2), this multilayer subsequently evolves into a dramatically more viscoelastic layer, containing a polymorphic network of micrometer-long fibrils growing from multiple nucleation sites; and 3), the fibrillar formation effectively stops as a result of the depletion of bulk-phase monomers, although the process can be continued without a lag phase by subsequent addition of fresh monomers. The robustness of the QCM-D technique, consolidated by complementary atomic force microscope studies, should make it possible to combine different components thought to be involved in the plaque formation process and thus build up realistic models of amyloid plaque formation in vitro.

  14. A Label-Free Immunosensor for Ultrasensitive Detection of Ketamine Based on Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Ya Yang

    2015-04-01

    Full Text Available In this study, we have developed a label-free immunosensor with the variation of resonance frequency (Δf of a quartz crystal microbalance (QCM as readout signal for ultrasensitive detection of Ketamine (KT. An optimized strategy for immobilization of KT antibody on the surface of the QCM chip was implemented via the self-assembly modification of 3-mercaptopropionic acid, and then activated with 1-ethyl-3- (3-dimethylaminoprophl carbodiimide and n-hydroxysuccinimide. The specific affinity between the antibody and the antigen ensured a selective response toward KT. The Δf linearly related to the concentration of KT in the range of 1 to 40 pg/mL, with a detection limit of 0.86 pg/mL (S/N = 3. The obtained immunosensor was applied to detect the KT in spiked human urine without any pretreatment but dilution with recoveries from 91.8% to 108%. The developed sensor is promising to perform the portable or on-spot KT detection in clinic or forensic cases.

  15. Exploiting Solvate Ionic Liquids for Amine Gas Analysis on a Quartz Crystal Microbalance.

    Science.gov (United States)

    Li, Hsin-Yi; Chu, Yen-Ho

    2017-05-16

    We demonstrated in this work the usefulness of solvate ionic liquids SIL 3 and SIL 4 for chemoselective detection of amine gases on a quartz crystal microbalance. This detection of gaseous amines was achieved by nucleophilic aromatic addition reactions with super electrophilic SIL 3 or SIL 4 thin-coated on quartz chips. Starting with inexpensive reagents, functional SIL 3 and SIL 4 could be readily synthesized in two short steps with high isolated yield (81 and 77%, respectively). The QCM platform developed in this work is readily applicable and highly sensitive to low molecular weight amine gases: for propylamine gas at 10 Hz decrease in resonance frequency, the sensitivity of detection using SIL 4 was 5.4 ppb. This simple and convenient assembly of neutral ligands (e.g., 1a and 1b) with Li(+) ion to afford room temperature ionic liquids should be of great importance for a myriad of applications. To the best of our knowledge, no example to date of reports based on nucleophilic aromatic addition reactions demonstrating sensitive amine gas detection in solvate ionic liquids on a QCM has been reported. Furthermore, because of the high color intensity of the Meisenheimer complexes formed, our preliminary result showed that SIL 4 loaded on copier paper can be used not only as a portable amine gas sensor but also as a potential invisible ink that is only revealed by amine vapor.

  16. Electrochemical quartz crystal microbalance study of the electrodeposition of Co, Pt and Pt-Co alloy

    Energy Technology Data Exchange (ETDEWEB)

    Martin, A.J.; Chaparro, A.M. [CIEMAT, Avda. Complutense, 22, 28040 Madrid (Spain); Daza, L. [CIEMAT, Avda. Complutense, 22, 28040 Madrid (Spain); Instituto de Catalisis y Petroleoquimica (CSIC), C/Marie Curie 2, Campus Cantoblanco, 28049 Madrid (Spain)

    2007-06-10

    The electrochemical deposition of Co, Pt and Pt-Co alloy are studied with the electrochemical quartz crystal microbalance (EQCM) on a gold substrate. Co is deposited from acidic sulphate bath containing boric acid. Different processes are identified in this bath. Electrodeposition of Co on Au substrate is observed at potentials above redox potential, underpotential deposition, most probably due to formation of a Co-Au alloy. At more cathodic potentials, below -0.5 V, metallic Co is formed. The film is completely dissolved at positive potentials during the anodic scan, probably mediated by Co(OH){sub 2}. The electrodeposition of platinum from acidic PtCl{sub 6}{sup 2-} bath occurs below the thermodynamic potential (0.74 V) with almost 100% efficiency. At potentials negative from 0.0 V the efficiency decreases due to parallel water reduction. The codeposition of Co and Pt is also studied in acidic bath. Here, the decrease of pH due to water reduction on Pt deposits gives rise to precipitation of Co(OH){sub 2}, together with the deposition of metallic Pt and Co. The films contain as major component the Pt{sub 3}Co alloy. (author)

  17. Electrochemical quartz crystal microbalance study of the electrodeposition of Co, Pt and Pt-Co alloy

    Science.gov (United States)

    Martín, A. J.; Chaparro, A. M.; Daza, L.

    The electrochemical deposition of Co, Pt and Pt-Co alloy are studied with the electrochemical quartz crystal microbalance (EQCM) on a gold substrate. Co is deposited from acidic sulphate bath containing boric acid. Different processes are identified in this bath. Electrodeposition of Co on Au substrate is observed at potentials above redox potential, underpotential deposition, most probably due to formation of a Co-Au alloy. At more cathodic potentials, below -0.5 V, metallic Co is formed. The film is completely dissolved at positive potentials during the anodic scan, probably mediated by Co(OH) 2. The electrodeposition of platinum from acidic PtCl 6 2- bath occurs below the thermodynamic potential (0.74 V) with almost 100% efficiency. At potentials negative from 0.0 V the efficiency decreases due to parallel water reduction. The codeposition of Co and Pt is also studied in acidic bath. Here, the decrease of pH due to water reduction on Pt deposits gives rise to precipitation of Co(OH) 2, together with the deposition of metallic Pt and Co. The films contain as major component the Pt 3Co alloy.

  18. Probing the interaction between nanoparticles and lipid membranes by quartz crystal microbalance with dissipation monitoring

    Science.gov (United States)

    Yousefi, Nariman; Tufenkji, Nathalie

    2016-12-01

    There is increasing interest in using quartz crystal microbalance with dissipation monitoring (QCM-D) to investigate the interaction of nanoparticles (NPs) with model surfaces. The high sensitivity, ease of use and the ability to monitor interactions in real-time has made it a popular technique for colloid chemists, biologists, bioengineers and biophysicists. QCM-D has been recently used to probe the interaction of NPs with supported lipid bilayers (SLBs) as model cell membranes. The interaction of NPs with SLBs is highly influenced by the quality of the lipid bilayers. Unlike many surface sensitive techniques, using QCM-D, the quality of SLBs can be assessed in real-time, hence QCM-D studies on SLB-NP interactions are less prone to the artefacts arising from bilayers that are not well formed. The ease of use and commercial availability of a wide range of sensor surfaces also have made QCM-D a versatile tool for studying NP interactions with lipid bilayers. In this review, we summarize the state-of-the-art on QCM-D based techniques for probing the interactions of NPs with lipid bilayers.

  19. A Study of Drop-Microstructured Surface Interactions during Dropwise Condensation with Quartz Crystal Microbalance

    Science.gov (United States)

    Su, Junwei; Charmchi, Majid; Sun, Hongwei

    2016-10-01

    Dropwise condensation (DWC) on hydrophobic surfaces is attracting attention for its great potential in many industrial applications, such as steam power plants, water desalination, and de-icing of aerodynamic surfaces, to list a few. The direct dynamic characterization of liquid/solid interaction can significantly accelerate the progress toward a full understanding of the thermal and mass transport mechanisms during DWC processes. This work reports a novel Quartz Crystal Microbalance (QCM) based method that can quantitatively analyze the interaction between water droplets and micropillar surfaces during different condensation states such as filmwise, Wenzel, and partial Cassie states. A combined nanoimprinting lithography and chemical surface treatment approach was utilized to fabricate the micropillar based superhydrophobic and superhydrophilic surfaces on the QCM substrates. The normalized frequency shift of the QCM device together with the microscopic observation of the corresponding drop motion revealed the droplets growth and their coalescence processes and clearly demonstrated the differences between the three aforementioned condensation states. In addition, the transition between Cassie and Wenzel states was successfully captured by this method. The newly developed QCM system provides a valuable tool for the dynamic characterization of different condensation processes.

  20. Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection.

    Science.gov (United States)

    Mannelli, Ilaria; Minunni, Maria; Tombelli, Sara; Mascini, Marco

    2003-03-01

    A DNA piezoelectric sensor has been developed for the detection of genetically modified organisms (GMOs). Single stranded DNA (ssDNA) probes were immobilised on the sensor surface of a quartz crystal microbalance (QCM) device and the hybridisation between the immobilised probe and the target complementary sequence in solution was monitored. The probe sequences were internal to the sequence of the 35S promoter (P) and Nos terminator (T), which are inserted sequences in the genome of GMOs regulating the transgene expression. Two different probe immobilisation procedures were applied: (a) a thiol-dextran procedure and (b) a thiol-derivatised probe and blocking thiol procedure. The system has been optimised using synthetic oligonucleotides, which were then applied to samples of plasmidic and genomic DNA isolated from the pBI121 plasmid, certified reference materials (CRM), and real samples amplified by the polymerase chain reaction (PCR). The analytical parameters of the sensor have been investigated (sensitivity, reproducibility, lifetime etc.). The results obtained showed that both immobilisation procedures enabled sensitive and specific detection of GMOs, providing a useful tool for screening analysis in food samples.

  1. Frequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications

    Energy Technology Data Exchange (ETDEWEB)

    Montagut, Y. J.; Garcia, J. V.; Jimenez, Y.; Arnau, A. [Grupo de Fenomenos Ondulatorios, Departamento de Ingenieria Electronica, Universitat Politecnica de Valencia (Spain); March, C.; Montoya, A. [Instituto Interuniversitario de Investigacion en Bioingenieria y Tecnologia Orientada al Ser Humano, Universitat Politecnica de Valencia (Spain)

    2011-06-15

    The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of frequency stability due to the increase of the phase noise, particularly in oscillators, made impossible to reach the expected resolution. A new concept of sensor characterization at constant frequency has been recently proposed. The validation of the new concept is presented in this work. An immunosensor application for the detection of a low molecular weight contaminant, the insecticide carbaryl, has been chosen for the validation. An, in principle, improved version of a balanced-bridge oscillator is validated for its use in liquids, and applied for the frequency shift characterization of the QCM immunosensor application. The classical frequency shift characterization is compared with the new phase-shift characterization concept and system proposed.

  2. Electrochemical characterization of electrolytes and electrodes for lithium-ion batteries. Development of a new measuring method for electrochemical investigations on electrodes with the electrochemical quartz crystal microbalance (EQCM); Elektrochemische Charakterisierung von Elektrolyten und Elektroden fuer Lithium-Ionen-Batterien. Entwicklung einer neuen Messmethode fuer elektrochemische Untersuchungen an Elektroden mit der EQCM

    Energy Technology Data Exchange (ETDEWEB)

    Moosbauer, Dominik Johann

    2010-11-09

    In this work the conductivities of four different lithium salts, LiPF6, LiBF4, LiDFOB, and LiBOB in the solvent mixture EC/DEC (3/7) were investigated. Furthermore, the influence of eight ionic liquids (ILs) as additives on the conductivity and electrochemical stability of lithium salt-based electrolytes was studied. The investigated salts were the well-known lithium LiPF6 and LiDFOB. Conductivity studies were performed over the temperature range (238.15 to 333.15) K. The electrochemical stabilities of the solutions were determined at aluminum electrodes. The salt solubility of LiBF4 and LiDFOB in EC/DEC (3/7) was measured with the quartz crystal microbalance (QCM), a method developed in our group. Moreover, a method to investigate interactions between the electrolyte and electrode components with the electrochemical quartz crystal microbalance (EQCM) was developed. First, investigations of corrosion and passivation effects on aluminum with different lithium salts were performed and masses of deposited products estimated. Therefore, the quartzes were specially prepared with foils. Active materials of cathodes, in this work lithium iron phosphate (LiFePO4), were also investigated with the EQCM by a new method. [German] In dieser Arbeit wurden die Leitfaehigkeiten von vier unterschiedlichen Salzen, LiPF6, LiBF4, LiDFOB und LiBOB in dem Loesemittelgemisch EC/DEC (3/7) untersucht. Des Weiteren wurde der Einfluss von acht Ionischen Fluessigkeiten (ILs) als Additive fuer Lithium-Elektrolyte auf die elektrochemische Stabilitaet und die Leitfaehigkeit studiert. Die untersuchten Salze waren LiPF6 und LiDFOB. Die Leitfaehigkeitsmessungen wurden in einem Temperaturbereich von (238,15 bis 333,15) K durchgefuehrt. Die elektrochemischen Stabilitaeten der Elektrolyte fanden an Aluminium statt. Mit einer an der Arbeitsgruppe entwickelten neuen Methode wurden zudem die Salzloeslichkeiten von LiBF4 und LiDFOB in EC/DEC (3/7) mit der Quarzmikrowaage (QCM) bestimmt. Weiterhin wurden

  3. Colloidal Stability and Magnetic Field-Induced Ordering of Magnetorheological Fluids Studied with a Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Jaime Rodriguez-López

    2015-12-01

    Full Text Available This work proposes the use of quartz crystal microbalances (QCMs as a method to analyze and characterize magnetorheological (MR fluids. QCM devices are sensitive to changes in mass, surface interactions, and viscoelastic properties of the medium contacting its surface. These features make the QCM suitable to study MR fluids and their response to variable environmental conditions. MR fluids change their structure and viscoelastic properties under the action of an external magnetic field, this change being determined by the particle volume fraction, the magnetic field strength, and the presence of thixotropic agents among other factors. In this work, the measurement of the resonance parameters (resonance frequency and dissipation factor of a QCM are used to analyze the behavior of MR fluids in static conditions (that is, in the absence of external mechanical stresses. The influence of sedimentation under gravity and the application of magnetic fields on the shifts of resonance frequency and dissipation factor were measured and discussed in the frame of the coupled resonance produced by particles touching the QCM surface. Furthermore, the MR-fluid/QCM system has a great potential for the study of high-frequency contact mechanics because the translational and rotational stiffness of the link between the surface and the particles can be tuned by the magnetic field.

  4. A Review of Interface Electronic Systems for AT-cut Quartz Crystal Microbalance Applications in Liquids

    Directory of Open Access Journals (Sweden)

    Antonio Arnau

    2008-01-01

    Full Text Available From the first applications of AT-cut quartz crystals as sensors in solutionsmore than 20 years ago, the so-called quartz crystal microbalance (QCM sensor isbecoming into a good alternative analytical method in a great deal of applications such asbiosensors, analysis of biomolecular interactions, study of bacterial adhesion at specificinterfaces, pathogen and microorganism detection, study of polymer film-biomolecule orcell-substrate interactions, immunosensors and an extensive use in fluids and polymercharacterization and electrochemical applications among others. The appropriateevaluation of this analytical method requires recognizing the different steps involved andto be conscious of their importance and limitations. The first step involved in a QCMsystem is the accurate and appropriate characterization of the sensor in relation to thespecific application. The use of the piezoelectric sensor in contact with solutions stronglyaffects its behavior and appropriate electronic interfaces must be used for an adequatesensor characterization. Systems based on different principles and techniques have beenimplemented during the last 25 years. The interface selection for the specific application isimportant and its limitations must be known to be conscious of its suitability, and foravoiding the possible error propagation in the interpretation of results. This article presentsa comprehensive overview of the different techniques used for AT-cut quartz crystalmicrobalance in in-solution applications, which are based on the following principles:network or impedance analyzers, decay methods, oscillators and lock-in techniques. Theelectronic interfaces based on oscillators and phase-locked techniques are treated in detail,with the description of different configurations, since these techniques are the most used inapplications for detection of analytes in solutions, and in those where a fast sensorresponse is necessary.

  5. Interaction between Heparin and Fibronectin:Using Quartz Crystal Microbalance with Dissipation, Immunochemistry and Isothermal Titration Calorimetry

    Institute of Scientific and Technical Information of China (English)

    LI Guicai; WANG Caiping; YANG Ping; ZHOU Jie; ZHU Pingchuan

    2015-01-01

    The adsorption behavior of heparin and ifbronectin was studied by quartz crystal microbalance with dissipation (QCM-D), and the interaction between heparin and fibronectin was evaluated using immunochemistry and isothermal titration calorimetry (ITC) measurement. The results showed that there was competitive adsorption between heparin and fibronectin, and the preadsorption of fibronectin could prevent subsequent heparin adsorption to some extent, and the adsorbed Hep/Fn complex on the surface was in a rigid form. The bioactivity of heparin and ifbronectin could be affected by the bulk concentration of each, and both heparin and ifbronectin in Hep/Fn complex formed under pH 4 condition displayed larger bioactivity than that formed under pH 7 condition. Moreover, the ifbronectin showed more exposed cell-binding sites at the pH value lower than physiological condition. The results of ITC further suggested that the interaction between heparin and ifbronectin under pH 4 was stronger than under pH 7, and the complex was also more stable. The study brings forth the detailed interaction between heparin and ifbronectin, which will be helpful for better understanding the interaction mechanism of the two biomolecules. The results may be potentially useful for the development of new generation of cardiovascular biomaterials.

  6. Detection of NH{sub 3} by quartz crystal microbalance coated with TiO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Georgieva, V; Spassov, L; Gadjanova, V [Georgi Nadjakov Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee, 1784 Sofia (Bulgaria); Donkov, N; Petkov, P [Institute of Electronics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chausee, 1784 Sofia (Bulgaria)], E-mail: nikolaidd@abv.bg

    2008-05-01

    A quartz resonator with a thin TiO{sub 2} film is investigated in view of possible applications as a sensor for detecting the presence of ammonia in the ambient. A study of the sorption properties of thin TiO{sub 2} films to NH{sub 3} vapors is also presented. The films are deposited using electron beam evaporation. In order to determine the sorption ability of TiO{sub 2} to NH{sub 3}, a quartz crystal microbalance (QCM) with a thin TiO{sub 2} film is used, the latter serving as a receptor for the NH{sub 3} gas. The AT-cut 16-MHz quartz resonator allows conversion of the additional mass load that occurs as a result of sorption into a frequency shift. The experiments are carried out by measuring the QCM resonant frequency shift due to the absorption of vapors from an aqueous solution of NH{sub 3} with different concentration ranging from 100 to 1000 ppm. The experimental results obtained indicate that the variation of the resonant frequency is a function of the ammonia concentration. This demonstrates that a QCM covered with a thin TiO{sub 2} layer is sensitive to ammonia vapors at room temperature and is capable of detecting NH{sub 3} concentrations in the range investigated (100-1000 ppm)

  7. Monitoring the effects of fibrinogen concentration on blood coagulation using quartz crystal microbalance (QCM) and its comparison with thromboelastography

    Science.gov (United States)

    Lakshmanan, Ramji S.; Efremov, Vitaly; Cullen, Sinéad; Byrne, Barry; Killard, Anthony J.

    2013-05-01

    Fibrinogen has been identified as a major risk factor in cardiovascular disorders. Fibrinogen (340 kDa) is a soluble dimeric glycoprotein found in plasma and is a major component of the coagulation cascade. It has been identified as a major risk factor in cardiovascular disorders. The time taken for its conversion to fibrin is usually used as an "endpoint" in most clot-based assays, without any information on dynamic changes in physical properties or kinetics of a forming clot. A global coagulation profile as measured by Thromboelastography® (TEG®) provides information on both the time and kinetics of changes in physical property of the forming clot. In this work, Quartz crystal microbalance (QCM), which is a piezoelectric resonator has been used to study coagulation of plasma and compared with TEG. The changes in resonant frequency (Δf) and half width at half maximum (HWHM or ΔΓ) were used to evaluate effect of fibrinogen concentration. It has been shown that TEG is less sensitive to low concentrations of fibrinogen and dilution while QCM is able to monitor clot formation in both the circumstances.

  8. In situ NMR and electrochemical quartz crystal microbalance techniques reveal the structure of the electrical double layer in supercapacitors.

    Science.gov (United States)

    Griffin, John M; Forse, Alexander C; Tsai, Wan-Yu; Taberna, Pierre-Louis; Simon, Patrice; Grey, Clare P

    2015-08-01

    Supercapacitors store charge through the electrosorption of ions on microporous electrodes. Despite major efforts to understand this phenomenon, a molecular-level picture of the electrical double layer in working devices is still lacking as few techniques can selectively observe the ionic species at the electrode/electrolyte interface. Here, we use in situ NMR to directly quantify the populations of anionic and cationic species within a working microporous carbon supercapacitor electrode. Our results show that charge storage mechanisms are different for positively and negatively polarized electrodes for the electrolyte tetraethylphosphonium tetrafluoroborate in acetonitrile; for positive polarization charging proceeds by exchange of the cations for anions, whereas for negative polarization, cation adsorption dominates. In situ electrochemical quartz crystal microbalance measurements support the NMR results and indicate that adsorbed ions are only partially solvated. These results provide new molecular-level insight, with the methodology offering exciting possibilities for the study of pore/ion size, desolvation and other effects on charge storage in supercapacitors.

  9. Towards vibrational spectroscopy on surface-attached colloids performed with a quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Diethelm Johannsmann

    2016-12-01

    Full Text Available Colloidal spheres attached to a quartz crystal microbalance (QCM produce the so-called “coupled resonances”. They are resonators of their own, characterized by a particle resonance frequency, a resonance bandwidth, and a modal mass. When the frequency of the main resonator comes close to the frequency of the coupled resonance, the bandwidth goes through a maximum. A coupled resonance can be viewed as an absorption line in acoustic shear-wave spectroscopy. The known concepts from spectroscopy apply. This includes the mode assignment problem, selection rules, and the oscillator strength. In this work, the mode assignment problem was addressed with Finite Element calculations. These reveal that a rigid sphere in contact with a QCM displays two modes of vibration, termed “slipping” and “rocking”. In the slipping mode, the sphere rotates about its center; it exerts a tangential force onto the resonator surface at the point of contact. In the rocking mode, the sphere rotates about the point of contact; it exerts a torque onto the substrate. In liquids, both axes of rotation are slightly displaced from their ideal positions. Characteristic for spectroscopy, the two modes do not couple to the mechanical excitation equally well. The degree of coupling is quantified by an oscillator strength. Because the rocking mode mostly exerts a torque (rather than a tangential force, its coupling to the resonator's tangential motion is weak; the oscillator strength consequently is small. Recent experiments on surface-adsorbed colloidal spheres can be explained by the mode of vibration being of the rocking type.

  10. Quartz crystal microbalance study of the kinetics of surface initiated polymerization

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Surface initiated polymerization (SIP) is a valuable tool in synthesizing functional polymer brushes,yet the kinetic understanding of SIP lags behind the development of its application. We apply quartz crystal microbalance (QCM) to address two issues that are not fully addressed yet play a central role in the rational design of functional polymer brushes,namely quantitative determination of the kinetics and the initiator efficiency (IE) of SIP. SIP are monitored online using QCM. Two quantitative frequencythickness (f-T) relations make the direct determination and comparison of the rate of polymerization possible even for different monomers. Based on the bi-termination model,the kinetics of SIP is simply described by two variables,which are related to two polymerization constants,namely a = 1/(kp,s,app-[M][R·]0) and b = kt,s,app/(kp,s,app[M]). Factors that could alter the kinetics of SIP are studied,including (i) the molecular weight of monomers,(ii) the solvent used,(iii) the initial density of the initiator,(iv) the concentration of monomer,[M],and (v) the catalyst system (ratio among the ingredients,metal,ligands,and additives). The dynamic nature of IE is also described by these two variables,IE = a/(a + bt). Instead of the molecular weight and the polydispersity,we suggest that film thickness,the two kinetic parameters (a and b),and the initial density of the initiator and IE be the parameters that characterize ultrathin polymer brushes. Besides the kinetics study of SIP,the reported method has many other applications,for example,in the fast screening of catalyst system for SIP and other polymerization systems.

  11. Arsenic species interactions with a porous carbon electrode as determined with an electrochemical quartz crystal microbalance

    Science.gov (United States)

    Morallón, Emilia; Arias-Pardilla, Joaquín; Calo, J.M.; Cazorla-Amorós, D.

    2009-01-01

    The interactions of arsenic species with platinum and porous carbon electrodes were investigated with an electrochemical quartz crystal microbalance (EQCM) and cyclic voltammetry in alkaline solutions. It is shown that the redox reactions in arsenic-containing solutions, due to arsenic reduction/deposition, oxidation/desorption, and electrocatalyzed oxidation by Pt can be readily distinguished with the EQCM. This approach was used to show that the arsenic redox reactions on the carbon electrode are mechanistically similar to that on the bare Pt electrode. This could not be concluded with just classical cyclic voltammetry alone due to the obfuscation of the faradaic features by the large capacitative effects of the carbon double layer. For the porous carbon electrode, a continual mass loss was always observed during potential cycling, with or without arsenic in the solution. This was attributed to electrogasification of the carbon. The apparent mass loss per cycle was observed to decrease with increasing arsenic concentration due to a net mass increase in adsorbed arsenic per cycle that increased with arsenic concentration, offsetting the carbon mass loss. Additional carbon adsorption sites involved in arsenic species interactions are created during electrogasification, thereby augmenting the net uptake of arsenic per cycle. It is demonstrated that EQCM, and in particular the information given by the behavior of the time derivative of the mass vs. potential, or massogram, is very useful for distinguishing arsenic species interactions with carbon electrodes. It may also prove to be effective for investigating redox/adsorption/desorption behavior of other species in solution with carbon materials as well. PMID:20161369

  12. Arsenic species interactions with a porous carbon electrode as determined with an electrochemical quartz crystal microbalance.

    Science.gov (United States)

    Morallón, Emilia; Arias-Pardilla, Joaquín; Calo, J M; Cazorla-Amorós, D

    2009-06-30

    The interactions of arsenic species with platinum and porous carbon electrodes were investigated with an electrochemical quartz crystal microbalance (EQCM) and cyclic voltammetry in alkaline solutions. It is shown that the redox reactions in arsenic-containing solutions, due to arsenic reduction/deposition, oxidation/desorption, and electrocatalyzed oxidation by Pt can be readily distinguished with the EQCM. This approach was used to show that the arsenic redox reactions on the carbon electrode are mechanistically similar to that on the bare Pt electrode. This could not be concluded with just classical cyclic voltammetry alone due to the obfuscation of the faradaic features by the large capacitative effects of the carbon double layer.For the porous carbon electrode, a continual mass loss was always observed during potential cycling, with or without arsenic in the solution. This was attributed to electrogasification of the carbon. The apparent mass loss per cycle was observed to decrease with increasing arsenic concentration due to a net mass increase in adsorbed arsenic per cycle that increased with arsenic concentration, offsetting the carbon mass loss. Additional carbon adsorption sites involved in arsenic species interactions are created during electrogasification, thereby augmenting the net uptake of arsenic per cycle.It is demonstrated that EQCM, and in particular the information given by the behavior of the time derivative of the mass vs. potential, or massogram, is very useful for distinguishing arsenic species interactions with carbon electrodes. It may also prove to be effective for investigating redox/adsorption/desorption behavior of other species in solution with carbon materials as well.

  13. Weak antibody-cyclodextrin interactions determined by quartz crystal microbalance and dynamic/static light scattering.

    Science.gov (United States)

    Härtl, Elisabeth; Dixit, Nitin; Besheer, Ahmed; Kalonia, Devendra; Winter, Gerhard

    2013-11-01

    In a quest to elucidate the mechanism by which hydroxypropyl β-cyclodextrin (HPβCD) stabilizes antibodies against shaking stress, two heavily debated hypotheses exist, namely that stabilization is due to HPβCD's surface activity, or due to specific interactions with proteins. In a previous study by Serno et al. (Pharm. Res. 30 (2013) 117), we could refute the first hypothesis by proving that, although HPβCD is slightly surface active, it does not displace the antibody at the air-water interface, and accordingly, its surface activity is not the underlying stabilizing mechanism. In the present study, we investigated the possibility of interactions between HPβCD and monoclonal antibodies as the potential stabilization mechanism using quartz crystal microbalance (QCM) and static as well as dynamic light scattering. In the presence of HPβCD, the adsorption of IgG antibodies in the native state (IgG A) and the unfolded state (IgG A and IgG B) on gold-coated quartz crystals was studied by QCM. Results show that HPβCD causes a reduction in protein adsorption in both the folded and the unfolded states, probably due to an interaction between the protein and the cyclodextrin, leading to a reduced hydrophobicity of the protein and consequently a lower extent of adsorption. These results were supported by investigation of the interaction between the native protein and HPβCD using static and dynamic light scattering experiments, which provide the protein-protein interaction parameters, B22 and kD, respectively. Both B22 and kD showed an increase in magnitude with increasing HPβCD-concentrations, indicating a rise in net repulsive forces between the protein molecules. This is further evidence for the presence of interactions between HPβCD and the studied antibodies, since an association of HPβCD on the protein surface leads to a change in the intermolecular forces between the protein molecules. In conclusion, this study provides evidence that the previously observed

  14. Detection of Glypican-3 Proteins for Hepatocellular Carcinoma Marker Using Wireless-Electrodeless Quartz-Crystal Microbalance

    Science.gov (United States)

    Ogi, Hirotsugu; Omori, Toshinobu; Hatanaka, Kenichi; Hirao, Masahiko; Nishiyama, Masayoshi

    2008-05-01

    Pure shear-wave resonances were excited and detected in 18- and 30-µm-thick electrodeless AT-cut quartz plates in liquids using line antennas contactlessly, achieving high-frequency quartz-crystal microbalances (QCMs). Their fundamental resonance frequencies (85 and 54 MHz) were monitored to study interactions in real time between human glypican-3 and an anti-glypican-3 antibody: glypican-3 is a prospective protein marker for hepatocellular carcinoma. Their affinity was determined by the Langmuir kinetics. This study demonstrates the high ability of the wireless-electrodeless QCM for detection of the protein markers and development of drugs for disorders.

  15. Determination of flux ionization fraction using a quartz crystal microbalance and a gridded energy analyzer in an ionized magnetron sputtering system

    Science.gov (United States)

    Green, K. M.; Hayden, D. B.; Juliano, D. R.; Ruzic, D. N.

    1997-12-01

    A diagnostic which combines a quartz crystal microbalance (QCM) and a gridded energy analyzer has been developed to measure the metal flux ionization fraction in a modified commercial dc magnetron sputtering device. The sensor is mounted on a linear motion feedthrough and embedded in a slot in the substrate plane to allow for measuring the uniformity in deposition and ionization throughout the plane of the wafer. Radio-frequency (rf) power is introduced through a coil to ionize the Al atoms. The metal flux ionization fraction at the QCM is determined by comparing the total deposition rate with and without a bias that screens out the ions, but that leaves the plasma undisturbed. By varying the voltage applied to the grids, the plasma potential is determined. At a pressure of 35 mTorr, a magnetron power of 2 kW, and a net rf power of 310±5 W, 78±5% ionization was found.

  16. Fully automatic spray-LBL machine with monitoring the real time growth of multilayer films using Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Shiratori S.

    2013-08-01

    Full Text Available A fully automatic spray-LBL machine with monitoring the real time growth of multilayer films using Quartz Crystal Microbalance (QCM techniques was newly developed. We established fully automatic spray layer-by-layer method by precisely controlling air pressure, solution flow, and spray pattern. The movement pattern towards the substrate during solution spraying allowed fabrication of a nano-scale, flat, thin film over a wide area. Optimization of spray conditions permitted fabrication of the flat film with high and low refractive indexes, and they were piled up alternatively to constitute a one-dimensional photonic crystal with near-infrared reflection characteristics. The heat shield effect of the near-infrared reflective film was also confirmed under natural sunlight. It was demonstrated that the fabrication using the automatic spray-LBL machine and real-time QCM monitoring allows the fabrication of optical quality thin films with precise thickness.

  17. Mass flux response comparisons of a 200-MHz surface acoustic wave (SAW) resonator microbalance to a 15-MHz thermoelectric quartz crystal microbalance (TQCM) in a high-vacuum environment

    Science.gov (United States)

    Wallace, Donald A.; Bowers, William D.

    1994-10-01

    Using a 200 MHz Surface Acoustic Wave (SAW) resonator device as a high-vacuum molecular deposition microbalance, similar to a bulk quartz crystal microbalance (QCM), and an often-used 15 MHz thermoelectric QCM (TQCM), a comparison of various parameters was made during a high-vacuum outgassing experiment. The source of molecular outgassing was a bright aluminum foil which was cooled to liquid nitrogen temperature and alternately, to ambient temperature. The two sensors, the SAW QCM and the TQCM were placed next to each other and viewed only the aluminum foil. In this high-vacuum environment, a comparison between various parameters, i.e., mass sensitivity, long term drift rate, stability, thermal effects and dynamic range of the SAW and the TQCM, was obtained.

  18. Soybean oil and methyl oleate adsorption onto a steel surface investigated using a quartz crystal microbalance with dissipation monitoring and atomic force microscopy**1

    Science.gov (United States)

    The United States’ 2010 annual production of soybean oil exceeded 8 million metric tons, making a significant vegetable oil surplus available for new uses, particularly as a lubricant. Investigation of soybean oil and methyl oleate adsorption onto steel using a quartz crystal microbalance with diss...

  19. Lipid phase behavior studied with a quartz crystal microbalance: A technique for biophysical studies with applications in screening

    Science.gov (United States)

    Peschel, Astrid; Langhoff, Arne; Uhl, Eva; Dathathreyan, Aruna; Haindl, Susanne; Johannsmann, Diethelm; Reviakine, Ilya

    2016-11-01

    Quartz crystal microbalance (QCM) is emerging as a versatile tool for studying lipid phase behavior. The technique is attractive for fundamental biophysical studies as well applications because of its simplicity, flexibility, and ability to work with very small amounts of material crucial for biomedical studies. Further progress hinges on the understanding of the mechanism, by which a surface-acoustic technique such as QCM, senses lipid phase changes. Here, we use a custom-built instrument with improved sensitivity to investigate phase behavior in solid-supported lipid systems of different geometries (adsorbed liposomes and bilayers). We show that we can detect a model anesthetic (ethanol) through its effect on the lipid phase behavior. Further, through the analysis of the overtone dependence of the phase transition parameters, we show that hydrodynamic effects are important in the case of adsorbed liposomes, and viscoelasticity is significant in supported bilayers, while layer thickness changes make up the strongest contribution in both systems.

  20. Detecting cells on the surface of a silver electrode quartz crystal microbalance using plasma treatment and graft polymerization.

    Science.gov (United States)

    Chou, Hung-Che; Yan, Tsong-Rong; Chen, Ko-Shao

    2009-10-15

    This paper utilizes a silver electrode quartz crystal microbalance (QCM) mass sensor to detect the physiology of cells. This study also investigates the plasma surface modification of silver electrode QCMs through deposition of hexamethyldisilazane (HMDSZ) films as a protection film. To improve the cell growth, this paper also performs post-treatments by surface-grafting acrylic acid (AAc), acrylamide (AAm), and oxygen plasma treatment onto the QCM electrodes. Experimental results indicate that plasma deposition is a useful technique to protect the surface of silver electrodes. This technique extends the unpeeling time of silver electrodes from 1 to 7 days. The hydrophilic silver electrode QCM surface modified by AAm exhibited a better storage time effect than other post-treatments.

  1. Development of a mass sensitive quartz crystal microbalance (QCM)-based DNA biosensor using a 50 MHz electronic oscillator circuit.

    Science.gov (United States)

    García-Martinez, Gonzalo; Bustabad, Enrique Alonso; Perrot, Hubert; Gabrielli, Claude; Bucur, Bogdan; Lazerges, Mathieu; Rose, Daniel; Rodriguez-Pardo, Loreto; Fariña, Jose; Compère, Chantal; Vives, Antonio Arnau

    2011-01-01

    This work deals with the design of a high sensitivity DNA sequence detector using a 50 MHz quartz crystal microbalance (QCM) electronic oscillator circuit. The oscillator circuitry is based on Miller topology, which is able to work in damping media. Calibration and experimental study of frequency noise are carried out, finding that the designed sensor has a resolution of 7.1 ng/cm(2) in dynamic conditions (with circulation of liquid). Then the oscillator is proved as DNA biosensor. Results show that the system is able to detect the presence of complementary target DNAs in a solution with high selectivity and sensitivity. DNA target concentrations higher of 50 ng/mL can be detected.

  2. Development of a Mass Sensitive Quartz Crystal Microbalance (QCM-Based DNA Biosensor Using a 50 MHz Electronic Oscillator Circuit

    Directory of Open Access Journals (Sweden)

    Claude Gabrielli

    2011-08-01

    Full Text Available This work deals with the design of a high sensitivity DNA sequence detector using a 50 MHz quartz crystal microbalance (QCM electronic oscillator circuit. The oscillator circuitry is based on Miller topology, which is able to work in damping media. Calibration and experimental study of frequency noise are carried out, finding that the designed sensor has a resolution of 7.1 ng/cm2 in dynamic conditions (with circulation of liquid. Then the oscillator is proved as DNA biosensor. Results show that the system is able to detect the presence of complementary target DNAs in a solution with high selectivity and sensitivity. DNA target concentrations higher of 50 ng/mL can be detected.

  3. Determination of isoelectric points and the role of pH for common quartz crystal microbalance sensors.

    Science.gov (United States)

    Cuddy, Michael F; Poda, Aimee R; Brantley, Lauren N

    2013-05-01

    Isoelectric points (IEPs) were determined by the method of contact angle titration for five common quartz crystal microbalance (QCM) sensors. The isoelectric points range from mildly basic in the case of Al2O3 sensors (IEP = 8.7) to moderately acidic for Au (5.2) and SiO2 (3.9), to acidic for Ag (3.2) and Ti (2.9). In general, the values reported here are indicative of inherent surface oxides. A demonstration of the effect of the surface isoelectric point on the packing efficiency of thin mucin films is provided for gold and silica QCM sensors. It is determined that mucin layers on both substrates achieve a maximum and equal layer density of ∼3500 kg/m(3) at the corresponding IEP of either QCM sensor. This implies that mucin film packing is dependent upon short-range electrostatic interactions at the sensor surface.

  4. Equilibrium Water Contents of Cellulose Films Determined via Solvent Exchange and Quartz Crystal Microbalance with Dissipation Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kittle, Joshua D; Du, Xiaosong; Jiang, Feng; Qian, Chen; Heinze, Thomas; Roman, Maren; Esker, Alan R

    2011-08-08

    Model cellulose surfaces have attracted increasing attention for studying interactions with cell wall matrix polymers and as substrates for enzymatic degradation studies. Quartz crystal microbalance with dissipation monitoring (QCM-D) solvent exchange studies showed that the water content of regenerated cellulose (RC) films was proportional to the film thickness (d) and was consistent with about five water molecules per anhydroglucose unit. Sulfated nanocrystalline cellulose (SNC) and desulfated nanocrystalline cellulose (DNC) films had comparable water contents and contained about five times more water than RC films. A cellulase mixture served as a probe for studies of substrate accessibility and degradation. Cellulase adsorption onto RC films was independent of d, whereas degradation times increased with d. However, adsorption onto SNC and DNC films increased with d, whereas cellulase degradation times for DNC films were independent of studied d. Enhanced access to guest molecules for SNC and DNC films revealed they are more porous than RC films.

  5. Equilibrium water contents of cellulose films determined via solvent exchange and quartz crystal microbalance with dissipation monitoring.

    Science.gov (United States)

    Kittle, Joshua D; Du, Xiaosong; Jiang, Feng; Qian, Chen; Heinze, Thomas; Roman, Maren; Esker, Alan R

    2011-08-08

    Model cellulose surfaces have attracted increasing attention for studying interactions with cell wall matrix polymers and as substrates for enzymatic degradation studies. Quartz crystal microbalance with dissipation monitoring (QCM-D) solvent exchange studies showed that the water content of regenerated cellulose (RC) films was proportional to the film thickness (d) and was consistent with about five water molecules per anhydroglucose unit. Sulfated nanocrystalline cellulose (SNC) and desulfated nanocrystalline cellulose (DNC) films had comparable water contents and contained about five times more water than RC films. A cellulase mixture served as a probe for studies of substrate accessibility and degradation. Cellulase adsorption onto RC films was independent of d, whereas degradation times increased with d. However, adsorption onto SNC and DNC films increased with d, whereas cellulase degradation times for DNC films were independent of studied d. Enhanced access to guest molecules for SNC and DNC films revealed they are more porous than RC films.

  6. Mercury Sorption and Desorption on Gold: A Comparative Analysis of Surface Acoustic Wave and Quartz Crystal Microbalance-Based Sensors.

    Science.gov (United States)

    Kabir, K M Mohibul; Sabri, Ylias M; Esmaielzadeh Kandjani, Ahmad; Matthews, Glenn I; Field, Matthew; Jones, Lathe A; Nafady, Ayman; Ippolito, Samuel J; Bhargava, Suresh K

    2015-08-04

    Microelectromechanical sensors based on surface acoustic wave (SAW) and quartz crystal microbalance (QCM) transducers possess substantial potential as online elemental mercury (Hg(0)) vapor detectors in industrial stack effluents. In this study, a comparison of SAW- and QCM-based sensors is performed for the detection of low concentrations of Hg(0) vapor (ranging from 24 to 365 ppbv). Experimental measurements and finite element method (FEM) simulations allow the comparison of these sensors with regard to their sensitivity, sorption and desorption characteristics, and response time following Hg(0) vapor exposure at various operating temperatures ranging from 35 to 75 °C. Both of the sensors were fabricated on quartz substrates (ST and AT cut quartz for SAW and QCM devices, respectively) and employed thin gold (Au) layers as the electrodes. The SAW-based sensor exhibited up to ∼111 and ∼39 times higher response magnitudes than did the QCM-based sensor at 35 and 55 °C, respectively, when exposed to Hg(0) vapor concentrations ranging from 24 to 365 ppbv. The Hg(0) sorption and desorption calibration curves of both sensors were found to fit well with the Langmuir extension isotherm at different operating temperatures. Furthermore, the Hg(0) sorption and desorption rate demonstrated by the SAW-based sensor was found to decrease as the operating temperature increased, while the opposite trend was observed for the QCM-based sensor. However, the SAW-based sensor reached the maximum Hg(0) sorption rate faster than the QCM-based sensor regardless of operating temperature, whereas both sensors showed similar response times (t90) at various temperatures. Additionally, the sorption rate data was utilized in this study in order to obtain a faster response time from the sensor upon exposure to Hg(0) vapor. Furthermore, comparative analysis of the developed sensors' selectivity showed that the SAW-based sensor had a higher overall selectivity (90%) than did the QCM

  7. Effective antibodies immobilization and functionalized nanoparticles in a quartz-crystal microbalance-based immunosensor for the detection of parathion

    Science.gov (United States)

    Della Ventura, Bartolomeo; Iannaccone, Marco; Funari, Riccardo; Pica Ciamarra, Massimo; Altucci, Carlo; Capparelli, Rosanna; Roperto, Sante; Velotta, Raffaele

    2017-01-01

    Background Biosensor-based detection provides a rapid and low-cost alternative to conventional analytical methods for revealing the presence of the contaminants in water as well as solid matrices. Although important to be detected, small analytes (few hundreds of Daltons) are an issue in biosensing since the signal they induce in the transducer, and specifically in a Quartz-Crystal Microbalance, is undetectable. A pesticide like parathion (M = 292 Da) is a typical example of contaminant for which a signal amplification procedure is desirable. Methods/Findings The ballasting of the analyte by gold nanoparticles has been already applied to heavy target as proteins or bacteria to improve the limit of detection. In this paper, we extend the application of such a method to small analytes by showing that once the working surface of a Quartz-Crystal Microbalance (QCM) has been properly functionalized, a limit of detection lower than 1 ppb is reached for parathion. The effective surface functionalization is achieved by immobilizing antibodies upright oriented on the QCM gold surface by a simple photochemical technique (Photonic Immobilization Technique, PIT) based on the UV irradiation of the antibodies, whereas a simple protocol provided by the manufacturer is applied to functionalize the gold nanoparticles. Thus, in a non-competitive approach, the small analyte is made detectable by weighing it down through a “sandwich protocol” with a second antibody tethered to heavy gold nanoparticles. The immunosensor has been proved to be effective against the parathion while showing no cross reaction when a mixture of compounds very similar to parathion is analyzed. Conclusion/Significance The immunosensor described in this paper can be easily applied to any small molecule for which polyclonal antibodies are available since both the functionalization procedure of the QCM probe surface and gold nanoparticle can be applied to any IgG, thereby making our device of general

  8. Small organic molecules detection based on aptamer-modified gold nanoparticles-enhanced quartz crystal microbalance with dissipation biosensor.

    Science.gov (United States)

    Zheng, Bin; Cheng, Sheng; Liu, Wei; Lam, Michael Hon-Wah; Liang, Haojun

    2013-07-15

    Small molecules are difficult to detect by the conventional quartz crystal microbalance with dissipation (QCM-D) technique directly because the changes in frequency resulting from the binding processes of small biomolecules are often small. In the current study, an aptamer-based gold nanoparticles (AuNPs)-enhanced sensing strategy for detection of small molecules was developed. The QCM crystal was first modified with a layer of thiolated linker DNA, which can be partly base-paired with the detection part containing the adenosine aptamer sequence. In the presence of adenosine, the aptamer bound with adenosine and folded to the complex structure, which precluded the reporter part carrying AuNPs to combine with the random coiled detection part. Therefore, the lower the concentration of adenosine, the more AuNPs combined to the crystal. The resulting aptasensor showed a linear response to the increase of the adenosine concentration in the range of 0-2 μM with a linear correlation of r=0.99148 and a detection limit of 65 nM. Moreover, the aptasensor exhibited several excellent characteristics such as high sensitivity, selectivity, good stability, and reproducibility.

  9. Pathogen detection in complex samples by quartz crystal microbalance sensor coupled to aptamer functionalized core-shell type magnetic separation.

    Science.gov (United States)

    Ozalp, Veli C; Bayramoglu, Gulay; Erdem, Zehra; Arica, M Yakup

    2015-01-01

    A quartz crystal microbalance sensor (QCM) was developed for sensitive and specific detection of Salmonella enterica serovar typhimurium cells in food samples by integrating a magnetic bead purification system. Although many sensor formats based on bioaffinity agents have been developed for sensitive and specific detection of bacterial cells, the development of robust sensor applications for food samples remained a challenging issue. A viable strategy would be to integrate QCM to a pre-purification system. Here, we report a novel and sensitive high throughput strategy which combines an aptamer-based magnetic separation system for rapid enrichment of target pathogens and a QCM analysis for specific and real-time monitoring. As a proof-of-concept study, the integration of Salmonella binding aptamer immobilized magnetic beads to the aptamer-based QCM system was reported in order to develop a method for selective detection of Salmonella. Since our magnetic separation system can efficiently capture cells in a relatively short processing time (less than 10 min), feeding captured bacteria to a QCM flow cell system showed specific detection of Salmonella cells at 100 CFU mL(-1) from model food sample (i.e., milk). Subsequent treatment of the QCM crystal surface with NaOH solution regenerated the aptamer-sensor allowing each crystal to be used several times.

  10. An Electrochemical Quartz Crystal Microbalance Multisensor System Based on Phthalocyanine Nanostructured Films: Discrimination of Musts

    Directory of Open Access Journals (Sweden)

    Celia Garcia-Hernandez

    2015-11-01

    Full Text Available An array of electrochemical quartz crystal electrodes (EQCM modified with nanostructured films based on phthalocyanines was developed and used to discriminate musts prepared from different varieties of grapes. Nanostructured films of iron, nickel and copper phthalocyanines were deposited on Pt/quartz crystals through the Layer by Layer technique by alternating layers of the corresponding phthalocyanine and poly-allylamine hydrochloride. Simultaneous electrochemical and mass measurements were used to study the mass changes accompanying the oxidation of electroactive species present in must samples obtained from six Spanish varieties of grapes (Juan García, Prieto Picudo, Mencía Regadío, Cabernet Sauvignon, Garnacha and Tempranillo. The mass and voltammetric outputs were processed using three-way models. Parallel Factor Analysis (PARAFAC was successfully used to discriminate the must samples according to their variety. Multi-way partial least squares (N-PLS evidenced the correlations existing between the voltammetric data and the polyphenolic content measured by chemical methods. Similarly, N-PLS showed a correlation between mass outputs and parameters related to the sugar content. These results demonstrated that electronic tongues based on arrays of EQCM sensors can offer advantages over arrays of mass or voltammetric sensors used separately.

  11. Label-free real-time acoustic sensing of microvesicle release from prostate cancer (PC3) cells using a Quartz Crystal Microbalance.

    Science.gov (United States)

    Stratton, Dan; Lange, Sigrun; Kholia, Sharad; Jorfi, Samireh; Antwi-Baffour, Samuel; Inal, Jameel

    2014-10-24

    Using a Quartz Crystal Microbalance with dissipation monitoring, QCM-D (label-free system) measuring changes in resonant frequency (Δf) that equate to mass deposited on a sensor, we showed the attachment, over a 60min period, of a monolayer of PC3 cells to the gold electrodes of the quartz crystal sensor, which had been rendered hydrophilic. That MVs were released upon BzATP stimulation of cells was confirmed by NTA analysis (average 250nm diameter), flow cytometry, showing high phosphatidylserine exposition and by fluorescent (Annexin V Alexa Fluor® 488-positive) and electron microscopy. Over a period of 1000s (16.7min) during which early apoptosis increased from 4% plateauing at 10% and late apoptosis rose to 2%, the Δf increased 20Hz, thereupon remaining constant for the last 1000s of the experiment. Using the Sauerbrey equation, the loss in mass, which corresponded to the release of 2.36×10(6)MVs, was calculated to be 23ng. We therefore estimated the mass of an MV to be 0.24pg. With the deposition on the QCM-D of 3.5×10(7)MVs over 200s, the decrease in Δf (Hz) gave an estimate of 0.235pg per MV.

  12. Electrochemical quartz crystal microbalance study on the two-electrode-system cyclic voltammetric behavior of Prussian blue films

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A two-channel electrochemical quartz crystal microbalance (EQCM) was used to investigate the cyclic voltammetric behavior of two Prussian blue (PB) film-modified Au electrodes in a two-electrode con-figuration in aqueous solution. The redox peaks observed in the two-electrode cyclic voltammogram (CV) are assigned to the intrinsic redox transitions among the Everitt’s salt, PB, and Prussian yellow for the film itself, the redox process of the Au substrate and the redox process of small-quantity ferri-/ferrocyanide impurities entrapped in the PB film, as also supported by ultraviolet-visible (UV-Vis) spectroelectrochemical data. The profile of the two-electrode solid-state CV for the PB powder sand-wiched between two gold-coated indium-tin oxide (ITO) electrodes is similar to that for two PB-modified Au electrodes in aqueous solution, implying similar origins for the corresponding redox peaks. The two-channel EQCM method is expected to become a highly effective technique for the studies of the two-electrode electrochemical behaviors of many other species/materials.

  13. A novel dendritic surfactant for enhanced microcystin-LR detection by double amplification in a quartz crystal microbalance biosensor.

    Science.gov (United States)

    Xia, Yuetong; Zhang, Jianping; Jiang, Long

    2011-08-01

    Enhanced sensitivity for the hepatotoxin microcystin-LR (MC-LR) was achieved in a quartz crystal microbalance (QCM) system via double amplification. For primary amplification, an innovative interface on the QCM was obtained as a matrix by the vesicle layer formed by our synthetic dendritic surfactant, bis (amidoethyl-carbamoylethyl) octadecylamine (C18N3). The vesicle matrix was then functionalised by an optimised concentration of monoclonal antibodies against MC-LR (anti-MC-LR) to detect the analyte. The results showed that a detection limit of 100 ng/mL was achieved by primary amplification. To achieve higher sensitivity, secondary amplification was implemented with anti-MC-LR gold nanoparticle (AuNPs) conjugates as probes, which lowered the detection limit for MC-LR to 1 ng/mL (the maximum concentration recommended by the World Health Organization [WHO] in drinking water for humans). The QCM immunosensor reported here has advantages such as high sensitivity, portability, simplicity, and cost-effectiveness for MC-LR detection. It would be uniquely superior compared with current MC-LR detection techniques for on-the-spot water detection. Furthermore, the methodology described here is also potentially significant in many fields for the routine monitoring of environmental and food safety.

  14. Biomolecular interactions and tools for their recognition: focus on the quartz crystal microbalance and its diverse surface chemistries and applications.

    Science.gov (United States)

    Cheng, Cathy I; Chang, Yi-Pin; Chu, Yen-Ho

    2012-03-07

    Interactions between molecules are ubiquitous and occur in our bodies, the food we eat, the air we breathe, and myriad additional contexts. Although numerous tools are available for the recognition of biomolecular interactions, such tools are often limited in their sensitivity, expensive, and difficult to modify for various uses. In contrast, the quartz crystal microbalance (QCM) has sub-nanogram detection capabilities, is label-free, is inexpensive to create, and can be readily modified with a number of diverse surface chemistries to detect and characterize diverse interactions. To maximize the versatility of the QCM, scientists need to know available methods by which QCM surfaces can be modified. Therefore, in addition to summarizing the various tools currently used for biomolecular recognition, explicating the fundamental principles of the QCM as a tool for biomolecular recognition, and comparing the QCM with other acoustic sensors, we systematically review the numerous types of surface chemistries-including hydrophobic bonds, ionic bonds, hydrogen bonds, self-assembled monolayers, plasma-polymerized films, photochemistry, and sensing ionic liquids-used to functionalize QCMs for various purposes. We also review the QCM's diverse applications, which include the detection of gaseous species, detection of carbohydrates, detection of nucleic acids, detection of non-enzymatic proteins, characterization of enzymatic activity, detection of antigens and antibodies, detection of cells, and detection of drugs. Finally, we discuss the ultimate goals of and potential barriers to the development of future QCMs.

  15. Real-time monitoring of peptic and tryptic digestions of bovine {beta}-casein using quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Huenerbein, Andreas [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany)]. E-mail: andreas.huenerbein@pharmazie.uni-halle.de; Schmelzer, Christian E.H. [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany); Neubert, Reinhard H.H. [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany)

    2007-02-12

    In this study peptic and tryptic digestions of bovine {beta}-casein were investigated using quartz crystal microbalance (QCM). {beta}-Casein, which was used as a model protein, was immobilized on the surface of the QCM sensor where its degradation caused shifts in the resonant frequency. Atomic force microscopy was applied for the characterization of the protein layer. Different pH-values for peptic or tryptic digestions were chosen to visualize their effect on enzyme activity. Lower frequency shifts were observed at pH-values deviating from those at the maximum enzyme activity. In the case of the peptic digestion the frequency shift at pH 4 was more than 10 times smaller than those at pH 2. The frequency shifts for tryptic digestions at pH 5.4 and pH 6.4 were about two thirds compared to that obtained for the digestion at pH 7.4. The identification of peptides using MALDI-ToF mass spectrometry was used for verification of the proteolyses of the immobilized protein. Furthermore, it was shown that the QCM technique allows close observation of the effect of different pH-values on the immobilized casein layer. All in all, QCM facilitates the monitoring of the progress of enzymatic reactions in real-time.

  16. Peptide-membrane interactions of arginine-tryptophan peptides probed using quartz crystal microbalance with dissipation monitoring.

    Science.gov (United States)

    Rydberg, Hanna A; Kunze, Angelika; Carlsson, Nils; Altgärde, Noomi; Svedhem, Sofia; Nordén, Bengt

    2014-07-01

    Membrane-active peptides include peptides that can cross cellular membranes and deliver macromolecular cargo as well as peptides that inhibit bacterial growth. Some of these peptides can act as both transporters and antibacterial agents. It is desirable to combine the knowledge from these two different fields of membrane-active peptides into design of new peptides with tailored actions, as transporters of cargo or as antibacterial substances, targeting specific membranes. We have previously shown that the position of the amino acid tryptophan in the peptide sequence of three arginine-tryptophan peptides affects their uptake and intracellular localization in live mammalian cells, as well as their ability to inhibit bacterial growth. Here, we use quartz crystal microbalance with dissipation monitoring to assess the induced changes caused by binding of the three peptides to supported model membranes composed of POPC, POPC/POPG, POPC/POPG/cholesterol or POPC/lactosyl PE. Our results indicate that the tryptophan position in the peptide sequence affects the way these peptides interact with the different model membranes and that the presence of cholesterol in particular seems to affect the membrane interaction of the peptide with an even distribution of tryptophans in the peptide sequence. These results give mechanistic insight into the function of these peptides and may aid in the design of membrane-active peptides with specified cellular targets and actions.

  17. Functionalized biocompatible polyelectrolyte multilayers for drug delivery: In situ investigation of mechanical properties by dissipative quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Habibi, Neda [Department of Informatics, Bioengineering, Robotics and Systems Engineering, University of Genova, Genova (Italy); Nanotechnology and Advanced Material Institute, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of); Pastorino, Laura, E-mail: laura.pastorino@unige.it [Department of Informatics, Bioengineering, Robotics and Systems Engineering, University of Genova, Genova (Italy); Ruggiero, Carmelina [Department of Informatics, Bioengineering, Robotics and Systems Engineering, University of Genova, Genova (Italy)

    2014-02-01

    Nanostructured polymeric capsules have been applied in different fields, and specifically are regarded as promising for smart drug delivery applications. The physical–chemical and mechanical properties, and thus the permeability of the polyelectrolyte multilayer shell, play an important role in efficient delivery. Quartz crystal microbalance working in liquid has been used for the characterization of the buildup process and of the viscoelastic properties of biocompatible multilayers and of their functionalization by S-layer proteins. Optical and scanning electron microscopy have been used for the morphological characterization of nanostructured capsules obtained at physiological conditions by the assembly of the characterized multilayers onto spherical cores and by their subsequent removal. The proposed functionalized biocompatible capsules can be regarded as promising candidates for smart drug delivery applications. - Graphical abstract: SEM image of nanostructured polymeric capsules made by 4 bilayers of collagen/alginate at pH 7.4. - Highlights: • Build-up of biocompatible multilayers and functionalization by S-layer proteins • Characterization of multilayer growth and mechanical properties by QCM • Fabrication of S-layer functionalized biocompatible capsules.

  18. Study of the Interaction of Trastuzumab and SKOV3 Epithelial Cancer Cells Using a Quartz Crystal Microbalance Sensor

    Directory of Open Access Journals (Sweden)

    Louise Elmlund

    2015-03-01

    Full Text Available Analytical methods founded upon whole cell-based assays are of importance in early stage drug development and in fundamental studies of biomolecular recognition. Here we have studied the binding of the monoclonal antibody trastuzumab to human epidermal growth factor receptor 2 (HER2 on human ovary adenocarcinoma epithelial cancer cells (SKOV3 using quartz crystal microbalance (QCM technology. An optimized procedure for immobilizing the cells on the chip surface was established with respect to fixation procedure and seeding density. Trastuzumab binding to the cell decorated sensor surface was studied, revealing a mean dissociation constant, KD, value of 7 ± 1 nM (standard error of the mean. This study provides a new perspective on the affinity of the antibody-receptor complex presented a more natural context compared to purified receptors. These results demonstrate the potential for using whole cell-based QCM assay in drug development, the screening of HER2 selective antibody-based drug candidates, and for the study of biomolecular recognition. This real time, label free approach for studying interactions with target receptors present in their natural environment afforded sensitive and detailed kinetic information about the binding of the analyte to the target.

  19. Humidity scanning quartz crystal microbalance with dissipation monitoring setup for determination of sorption-desorption isotherms and rheological changes

    Energy Technology Data Exchange (ETDEWEB)

    Björklund, Sebastian, E-mail: sebastianbjorklund@gmail.com; Kocherbitov, Vitaly [Department of Biomedical Science, Faculty of Health and Society, Malmö University, Malmö (Sweden); Biofilms—Research Center for Biointerfaces, Malmö University, Malmö (Sweden)

    2015-05-15

    A new method to determine water sorption-desorption isotherms with high resolution in the complete range of water activities (relative humidities) is presented. The method is based on quartz crystal microbalance with dissipation monitoring (QCM-D). The QCM-D is equipped with a humidity module in which the sample film is kept in air with controlled humidity. The experimental setup allows for continuous scanning of the relative humidity from either dry to humid conditions or vice versa. The amount of water sorbed or desorbed from the sample is determined from the resonance frequencies of the coated quartz sensor, via analysis of the overtone dependence. In addition, the method allows for characterization of hydration induced changes of the rheological properties from the dissipation data, which is closely connected to the viscoelasticity of the film. The accuracy of the humidity scanning setup is confirmed in control experiments. Sorption-desorption isotherms of pig gastric mucin and lysozyme, obtained by the new method, show good agreement with previous results. Finally, we show that the deposition technique used to coat the quartz sensor influences the QCM-D data and how this issue can be used to obtain further information on the effect of hydration. In particular, we demonstrate that spin-coating represents an attractive alternative to obtain sorption-desorption isotherms, while drop-coating provides additional information on changes of the rheological properties during hydration.

  20. Plasma proteins adsorption mechanism on polyethylene-grafted poly(ethylene glycol) surface by quartz crystal microbalance with dissipation.

    Science.gov (United States)

    Jin, Jing; Jiang, Wei; Yin, Jinghua; Ji, Xiangling; Stagnaro, Paola

    2013-06-04

    Protein adsorption has a vital role in biomaterial surface science because it is directly related to the hemocompatibility of blood-contacting materials. In this study, monomethoxy poly(ethylene glycol) (mPEG) with two different molecular weights was grafted on polyethylene as a model to elucidate the adsorption mechanisms of plasma protein through quartz crystal microbalance with dissipation (QCM-D). Combined with data from platelet adhesion, whole blood clotting time, and hemolysis rate, the blood compatibility of PE-g-mPEG film was found to have significantly improved. Two adsorption schemes were developed for real-time monitoring of protein adsorption. Results showed that the preadsorbed bovine serum albumin (BSA) on the surfaces of PE-g-mPEG films could effectively inhibit subsequent adsorption of fibrinogen (Fib). Nonspecific protein adsorption of BSA was determined by surface coverage, not by the chain length of PEG. Dense PEG brush could release more trapped water molecules to resist BSA adsorption. Moreover, the preadsorbed Fib could be gradually displaced by high-concentration BSA. However, the adsorption and displacement of Fib was determined by surface hydrophilicity.

  1. Microscopic insight into role of protein flexibility during ion exchange chromatography by nuclear magnetic resonance and quartz crystal microbalance approaches.

    Science.gov (United States)

    Hao, Dongxia; Ge, Jia; Huang, Yongdong; Zhao, Lan; Ma, Guanghui; Su, Zhiguo

    2016-03-18

    Driven by the prevalent use of ion exchange chromatography (IEC) for polishing therapeutic proteins, many rules have been formulated to summarize the different dependencies between chromatographic data and various operational parameters of interest based on statically determined interactions. However, the effects of the unfolding of protein structures and conformational stability are not as well understood. This study focuses on how the flexibility of proteins perturbs retention behavior at the molecular scale using microscopic characterization approaches, including hydrogen-deuterium (H/D) exchange detected by NMR and a quartz crystal microbalance (QCM). The results showed that a series of chromatographic retention parameters depended significantly on the adiabatic compressibility and structural flexibility of the protein. That is, softer proteins with higher flexibility tended to have longer retention times and stronger affinities on SP Sepharose adsorbents. Tracing the underlying molecular mechanism using NMR and QCM indicated that an easily unfolded flexible protein with a more compact adsorption layer might contribute to the longer retention time on adsorbents. The use of NMR and QCM provided a previously unreported approach for elucidating the effect of protein structural flexibility on binding in IEC systems.

  2. Detection of Staphylococcus epidermidis by a Quartz Crystal Microbalance Nucleic Acid Biosensor Array Using Au Nanoparticle Signal Amplification

    Directory of Open Access Journals (Sweden)

    Weiling Fu

    2008-10-01

    Full Text Available Staphylococcus epidermidis is a critical pathogen of nosocomial blood infections, resulting in significant morbidity and mortality. A piezoelectric quartz crystal microbalance (QCM nucleic acid biosensor array using Au nanoparticle signal amplification was developed to rapidly detect S. epidermidis in clinical samples. The synthesized thiolated probes specific targeting S. epidermidis 16S rRNA gene were immobilized on the surface of QCM nucleic acid biosensor arrays. Hybridization was induced by exposing the immobilized probes to the PCR amplified fragments of S. epidermidis, resulting in a mass change and a consequent frequency shift of the QCM biosensor. To further enhance frequency shift results from above described hybridizations, streptavidin coated Au nanoparticles were conjugated to the PCR amplified fragments. The results showed that the lowest detection limit of current QCM system was 1.3×103 CFU/mL. A linear correlation was found when the concentration of S. epidermidis varied from 1.3×103 to 1.3×107 CFU/mL. In addition, 55 clinical samples were detected with both current QCM biosensor system and conventional clinical microbiological method, and the sensitivity and specificity of current QCM biosensor system were 97.14% and 100%, respectively. In conclusion, the current QCM system is a rapid, low-cost and sensitive method that can be used to identify infection of S. epidermidis in clinical samples.

  3. A combined experimental and theoretical study on the immunoassay of human immunoglobulin using a quartz crystal microbalance.

    Science.gov (United States)

    Liao, Po-Jen; Chang, Jeng-Shian; Chao, Sheng D; Chang, Hung-Chi; Huang, Kuan-Rong; Wu, Kuang-Chong; Wung, Tzong-Shyan

    2010-01-01

    We investigate a immunoassay biosensor that employs a Quartz Crystal Microbalance (QCM) to detect the specific binding reaction of the (Human IgG1)-(Anti-Human IgG1) protein pair under physiological conditions. In addition to experiments, a three dimensional time domain finite element method (FEM) was used to perform simulations for the biomolecular binding reaction in microfluidic channels. In particular, we discuss the unsteady convective diffusion in the transportation tube, which conveys the buffer solution containing the analyte molecules into the micro-channel where the QCM sensor lies. It is found that the distribution of the analyte concentration in the tube is strongly affected by the flow field, yielding large discrepancies between the simulations and experimental results. Our analysis shows that the conventional assumption of the analyte concentration in the inlet of the micro-channel being uniform and constant in time is inadequate. In addition, we also show that the commonly used procedure in kinetic analysis for estimating binding rate constants from the experimental data would underestimate these rate constants due to neglected diffusion processes from the inlet to the reaction surface. A calibration procedure is proposed to supplement the basic kinetic analysis, thus yielding better consistency with experiments.

  4. A Combined Experimental and Theoretical Study on the Immunoassay of Human Immunoglobulin Using a Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Jeng-Shian Chang

    2010-12-01

    Full Text Available We investigate a immunoassay biosensor that employs a Quartz Crystal Microbalance (QCM to detect the specific binding reaction of the (Human IgG1-(Anti-Human IgG1 protein pair under physiological conditions. In addition to experiments, a three dimensional time domain finite element method (FEM was used to perform simulations for the biomolecular binding reaction in microfluidic channels. In particular, we discuss the unsteady convective diffusion in the transportation tube, which conveys the buffer solution containing the analyte molecules into the micro-channel where the QCM sensor lies. It is found that the distribution of the analyte concentration in the tube is strongly affected by the flow field, yielding large discrepancies between the simulations and experimental results. Our analysis shows that the conventional assumption of the analyte concentration in the inlet of the micro-channel being uniform and constant in time is inadequate. In addition, we also show that the commonly used procedure in kinetic analysis for estimating binding rate constants from the experimental data would underestimate these rate constants due to neglected diffusion processes from the inlet to the reaction surface. A calibration procedure is proposed to supplement the basic kinetic analysis, thus yielding better consistency with experiments.

  5. Ultra-sensitive detection of zinc oxide nanowires using a quartz crystal microbalance and phosphoric acid DNA

    Science.gov (United States)

    Jang, Kuewhan; You, Juneseok; Park, Chanhoo; Park, Hyunjun; Choi, Jaeyeong; Choi, Chang-Hwan; Park, Jinsung; Lee, Howon; Na, Sungsoo

    2016-09-01

    Recent advancements of nanomaterials have inspired numerous scientific and industrial applications. Zinc oxide nanowires (ZnO NWs) is one of the most important nanomaterials due to their extraordinary properties. However, studies performed over the past decade have reported toxicity of ZnO NWs. Therefore, there has been increasing demand for effective detection of ZnO NWs. In this study, we propose a method for the detection of ZnO NW using a quartz crystal microbalance (QCM) and DNA probes. The detection method is based on the covalent interaction between ZnO NWs and the phosphoric acid group of single-stranded DNA (i.e., linker DNA), and DNA hybridization between the linker DNA and the probe DNA strand on the QCM electrode. Rapid, high sensitivity, in situ detection of ZnO NWs was demonstrated for the first time. The limit of detection was 10-4 μg ml-1 in deionized water, which represents a sensitivity that is 100000 times higher than the toxic ZnO NW concentration level. Moreover, the selectivity of the ZnO NW detection method was demonstrated by comparison with other types of nanowires and the method was able to detect ZnO NWs in tap water sensitively even after stored for 14 d in a refrigerator. The performance of our proposed method was sufficient to achieve detection of ZnO NW in the ‘real-world’ environment.

  6. Combined Bacteria Microarray and Quartz Crystal Microbalance Approach for Exploring Glycosignatures of Nontypeable Haemophilus influenzae and Recognition by Host Lectins.

    Science.gov (United States)

    Kalograiaki, Ioanna; Euba, Begoña; Proverbio, Davide; Campanero-Rhodes, María A; Aastrup, Teodor; Garmendia, Junkal; Solís, Dolores

    2016-06-01

    Recognition of bacterial surface epitopes by host receptors plays an important role in the infectious process and is intimately associated with bacterial virulence. Delineation of bacteria-host interactions commonly relies on the detection of binding events between purified bacteria- and host-target molecules. In this work, we describe a combined microarray and quartz crystal microbalance (QCM) approach for the analysis of carbohydrate-mediated interactions directly on the bacterial surface, thus preserving the native environment of the bacterial targets. Nontypeable Haemophilus influenzae (NTHi) was selected as a model pathogenic species not displaying a polysaccharide capsule or O-antigen-containing lipopolysaccharide, a trait commonly found in several important respiratory pathogens. Here, we demonstrate the usefulness of NTHi microarrays for exploring the presence of carbohydrate structures on the bacterial surface. Furthermore, the microarray approach is shown to be efficient for detecting strain-selective binding of three innate immune lectins, namely, surfactant protein D, human galectin-8, and Siglec-14, to different NTHi clinical isolates. In parallel, QCM bacteria-chips were developed for the analysis of lectin-binding kinetics and affinity. This novel QCM approach involves capture of NTHi on lectin-derivatized chips followed by formaldehyde fixation, rendering the bacteria an integrated part of the sensor chip, and subsequent binding assays with label-free lectins. The binding parameters obtained for selected NTHi-lectin pairs provide further insights into the interactions occurring at the bacterial surface.

  7. Peptide-membrane interactions of arginine-tryptophan peptides probed using quartz crystal microbalance with dissipation monitoring.

    KAUST Repository

    Rydberg, Hanna A

    2014-04-18

    Membrane-active peptides include peptides that can cross cellular membranes and deliver macromolecular cargo as well as peptides that inhibit bacterial growth. Some of these peptides can act as both transporters and antibacterial agents. It is desirable to combine the knowledge from these two different fields of membrane-active peptides into design of new peptides with tailored actions, as transporters of cargo or as antibacterial substances, targeting specific membranes. We have previously shown that the position of the amino acid tryptophan in the peptide sequence of three arginine-tryptophan peptides affects their uptake and intracellular localization in live mammalian cells, as well as their ability to inhibit bacterial growth. Here, we use quartz crystal microbalance with dissipation monitoring to assess the induced changes caused by binding of the three peptides to supported model membranes composed of POPC, POPC/POPG, POPC/POPG/cholesterol or POPC/lactosyl PE. Our results indicate that the tryptophan position in the peptide sequence affects the way these peptides interact with the different model membranes and that the presence of cholesterol in particular seems to affect the membrane interaction of the peptide with an even distribution of tryptophans in the peptide sequence. These results give mechanistic insight into the function of these peptides and may aid in the design of membrane-active peptides with specified cellular targets and actions.

  8. Quantification of the viscoelasticity of the bond of biotic and abiotic particles adhering to solid-liquid interfaces using a window-equipped quartz crystal microbalance with dissipation.

    Science.gov (United States)

    van der Westen, Rebecca; van der Mei, Henny C; De Raedt, Hans; Olsson, Adam L J; Busscher, Henk J; Sharma, Prashant K

    2016-12-01

    The quartz-crystal-microbalance-with-dissipation (QCM-D) has become a powerful tool for studying the bond viscoelasticity of biotic and abiotic colloidal particles adhering to substratum surfaces. A window-equipped QCM-D allows high-throughput analysis of the average bond viscoelasticity, measuring over 10(6) particles simultaneously in one single experiment. Other techniques require laborious analyses of individual particles. In this protocol, the quantitative derivation of the spring-constant and drag-coefficient of the bond between adhering colloidal particles and substratum surfaces using QCM-D is explained for bacteria and silica particles, using the particle-mass derived for validation. Bond viscoelasticity is calculated using a coupled resonator model, paying special attention to the protocol for mathematical fitting needed to obtain reliable quantitative output. Knowledge of the viscoelasticity of the bond between colloidal particles and substratum surfaces facilitates development of new strategies to detach adhering particles from or retain them on a surface. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Direct measurement of gas solubility and diffusivity in poly(vinylidene fluoride) with a high-pressure microbalance

    DEFF Research Database (Denmark)

    von Solms, Nicolas; Zecchin, Nicoletta; Rubin, Adam

    2005-01-01

    We present solubility and diffusion data for the gases methane and carbon dioxide in the polymer poly(vinylidene fluoride). The polymer was cut from extruded piping intended for use in offshore oil and gas applications. Measurements were carried out using a purpose-built high-pressure microbalance....... These properties were determined in the temperature range 80-120degreesC and in the pressure range 50-150bar for methane and 20-40bar for carbon dioxide. In general, good agreement was obtained for similar measurements reported in the literature. Solubility follows a Henry's law (linear) dependence with pressure...

  10. Electrochemical quartz crystal microbalance study on Au-supported Pt adlayers for electrocatalytic oxidation of methanol in alkaline solution

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Underpotential deposition(UPD) of Cu on an Au electrode followed by redox replacement reaction(RRR) of CuUPD with a Pt source(H2PtCl6 or K2PtCl4) yielded Au-supported Pt adlayers(for short,Pt(CuUPD-Pt4+)n/Au for H2PtCl6,or Pt(CuUPD-Pt2+)n/Au for K2PtCl4,where n denotes the number of UPD-redox replacement cycles).The electrochemical quartz crystal microbalance(EQCM) technique was used for the first time to quantitatively study the fabricated electrodes and estimate their mass-normalized specific electrocatalytic activity(SECA) for methanol oxidation in alkaline solution.In comparison with Pt(CuUPD-Pt2+)n/Au,Pt(CuUPD-Pt4+)n/Au exhibited a higher electrocatalytic activity,and the maximum SECA was obtained to be as high as 35.7 mA ?g?1 at Pt(CuUPD-Pt4+)3/Au.The layer-by-layer architecture of Pt atoms on Au is briefly discussed based on the EQCM-revealed redox replacement efficiency,and the calculated distribution percentages of bare Au sites agree with the experimental results deduced from the charge under the AuOx-reduction peaks.The EQCM is highly recommended as an efficient technique to quantitatively examine various electrode-supported catalyst adlayers,and the highly efficient catalyst adlayers of noble metals are promising in electrocatalysis relevant to biological,energy and environmental sciences and technologies.

  11. Sequential adsorption of bovine mucin and lactoperoxidase to various substrates studied with quartz crystal microbalance with dissipation.

    Science.gov (United States)

    Halthur, Tobias J; Arnebrant, Thomas; Macakova, Lubica; Feiler, Adam

    2010-04-01

    Mucin and lactoperoxidase are both natively present in the human saliva. Mucin provides lubricating and antiadhesive function, while lactoperoxidase has antimicrobial activity. We propose that combined films of the two proteins can be used as a strategy for surface modification in biomedical applications such as implants or biosensors. In order to design and ultilize mixed protein films, it is necessary to understand the variation in adsorption behavior of the proteins onto different surfaces and how it affects their interaction. The quartz crystal microbalance with dissipation (QCM-D) technique has been used to extract information of the adsorption properties of bovine mucin (BSM) and lactoperoxidase (LPO) to gold, silica, and hydrophobized silica surfaces. The information has further been used to retrieve information of the viscoelastic properties of the adsorbed film. The adsorption and compaction of BSM were found to vary depending on the nature of the underlying bare surface, adsorbing as a thick highly hydrated film with loops and tails extending out in the bulk on gold and as a thinner film with much lower adsorbed amount on silica; and on hydrophobic surfaces, BSM adsorbs as a flat and much more compact layer. On gold and silica, the highly hydrated BSM film is cross-linked and compacted by the addition of LPO, whereas the compaction is not as pronounced on the already more compact film formed on hydrophobic surfaces. The adsorption of LPO to bare surfaces also varied depending on the type of surface. The adsorption profile of BSM onto LPO-coated surfaces mimicked the adsorption to the underlying surface, implying little interaction between the LPO and BSM. The interaction between the protein layers was interpreted as a combination of electrostatic and hydrophobic interactions, which was in turn influenced by the interaction of the proteins with the different substrates.

  12. Characterization of Self-assembled Monolayers on Gold Electrode Using Electrochemical Quartz Crystal Microbalance

    Institute of Scientific and Technical Information of China (English)

    Yonggui Dong

    2006-01-01

    The electrochemical quartz crystal microbatance (EQCM) is used to investigate the characteristics of the thiolated self-assembled monolayer(SAM) on gold surface. A 5MHz QCM element serves as both the mass-sensitive sensor and the working electrode of the electrochemical system. The 6-mecapto-1-hexanol and and the 16-mer oligonucleotide with a mercaptohexyl group at the 5'-phosphate end are utilized to form the SAM on the gold electrode. The frequency response of the QCM during cyclic voltammetry (CV) scanning and chronoamperometry are recorded together with the electrochemical current. The experimental results indicates that the frequency response is more sensitive to the surface coverage. Therefore, the response of the EQCM reveals more details of the SAM on gold electrode. It is especially useful for analysing the immobilization quality, such as probe orientation and coverage, of the SAM.

  13. Long Memory from Sauerbrey Equation: A Case in Coated Quartz Crystal Microbalance in terms of Ammonia

    Directory of Open Access Journals (Sweden)

    Xiaohua Wang

    2011-01-01

    Full Text Available The Sauerbrey equation is a useful empirical model in material science to represent the dynamics of frequency change denoted by Δf in an area, denoted by A, of the electrode in terms of the increment of the mass, which is denoted by Δm, loaded on the surface of the crystal under a certain resonant frequency f0. For the purpose of studying Δf from the point of view of time series, we first propose two types of the modified representations of the Sauerbrey equation by taking time as an argument to represent Δf as a function expressed by x(t,f0,A,Δm, where t is time. Usually, Δf is studied experimentally for the performance evaluation of the tested quartz used in ammonia sensors. Its properties in time series, however, are rarely reported. This paper presents the fractal properties of Δf. We will show that Δf is long range dependent (LRD. Consequently, it is heavy tailed according to the Taqqu's theorem. The Hurst parameter (H of Δf approaches one, implying its strong long memory, providing a new explanation of the repeatability of the experiments and novel point of view of the dynamics of Δf relating to the Sauerbrey equation in material science.

  14. Deposition of selenium thin layers on gold surfaces from sulphuric acid media: Studies using electrochemical quartz crystal microbalance, cyclic voltammetry and AFM

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Murilo Feitosa [Instituto de Quimica de Sao Carlos, Universidade de Sao Paulo, C.P. 780, 13566-590 Sao Carlos, SP (Brazil); Pedrosa, Valber A., E-mail: vzp0002@auburn.ed [Department of Materials Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL 36849 (United States); Spinola Machado, Sergio Antonio [Instituto de Quimica de Sao Carlos, Universidade de Sao Paulo, C.P. 780, 13566-590 Sao Carlos, SP (Brazil)

    2010-01-01

    In this paper we report here new considerations about the relationship between the mass and charge variations (m/z relationship) in underpotential deposition (UPD), bulk deposition and also in the H{sub 2}Se formation reaction. Nanogravimetric experiments were able to show the adsorption of H{sub 2}SeO{sub 3} on the AuO surface prior to the voltammetric sweep and that, after the AuO reduction, 0.40 monolayer of H{sub 2}SeO{sub 3} remains adsorbed on the newly reduced Au surface, which was enough to gives rise to the UPD layer. The UPD results indicate that the maximum coverage with Se{sub ads} on polycrystalline gold surface corresponds to approximately 0.40 monolayer, in good agreement with charge density results. The cyclic voltammetry experiments demonstrated that the amount of bulk Se obtained during the potential scan to approximately 2 Se monolayers, which was further confirmed by electrochemical quartz crystal microbalance (EQCM) measurements that pointed out a mass variation corresponding of 3 monolayers of Se. In addition, the Se thin films were obtained by chronoamperometric experiments, where the Au electrode was polarized at +0.10 V during different times in 1.0 M H{sub 2}SO{sub 4} + 1.0 mM SeO{sub 2}. The topologic aspects of the electrodeposits were observed in Atomic Force Microscope (AFM) measurements. Finally, in highly negative potential polarizations, the H{sub 2}Se formation was analyzed by voltammetric and nanogravimetric measurements. These finding brings a new light on the selenium electrodeposition and point up to a proposed electrochemical model for molecule controlled surface engineering.

  15. Evaluating the Effect of Surface Roughness on Titanium Dioxide Nanoparticle Deposition using a Combined Quartz Crystal Microbalance with Dissipation (QCM-D) and Generalized Ellipsometry (GE) Technique

    Science.gov (United States)

    Kananizadeh, N.; Lee, J.; Rodenhausen, K. B.; Sekora, D.; Schubert, M.; Schubert, E.; Bartelt-Hunt, S.; Li, Y.

    2016-12-01

    Quantification and characterization of nanoparticles in soils and sediments are very challenging because they will interact not only with soil-water chemistry but also with highly heterogeneous soil and sediment surfaces. In this work, we measured the interaction of Titanium dioxide nanoparticles (nTiO2), the most extensively manufactured engineered materials, with engineered rough surfaces under varied ionic strength conditions. Innovative three-dimensional Silicon nanostructured surfaces, referred to here as slanted columnar thin films (SCTFs), were used to generate surface roughness with controlled heights of 50nm, 100nm, and 200nm. Using atomic layer deposition technique (ALD), surfaces of SCTF were coated with either silicon dioxide or aluminum oxides to represent the most abundant silica aquifer materials and metal oxide impurities, respectively. The interaction between nTiO2 and model rough surfaces was measured using quartz crystal microbalance with dissipation monitoring (QCM-D). The data were analyzed using a model that couples the viscoelastic effect with the surface roughness effect. No nTiO2 deposition was observed on neither flat nor rough silicon dioxide surfaces under ionic strength ranged from 0 to 100 mM NaCl. On the other hand, the deposition of nTiO2 on the aluminum oxides coated surfaces increased as the height of roughness increased. In parallel with QCM-D, a Generalized Ellipsometry (GE) was used to measure the mass of deposited nTiO2. The combination of QCM-D and GE revealed that the properties (i.e. porosity and rigidness) of attached nTiO2 layer on the QCM-D surfaces were dependent on ionic strength and surface roughness.

  16. Adsorption of cobalt ferrite nanoparticles within layer-by-layer films: a kinetic study carried out using quartz crystal microbalance.

    Science.gov (United States)

    Alcantara, Gustavo B; Paterno, Leonardo G; Afonso, André S; Faria, Ronaldo C; Pereira-da-Silva, Marcelo A; Morais, Paulo C; Soler, Maria A G

    2011-12-28

    The paper reports on the successful use of the quartz crystal microbalance technique to assess accurate kinetics and equilibrium parameters regarding the investigation of in situ adsorption of nanosized cobalt ferrite particles (CoFe(2)O(4)--10.5 nm-diameter) onto two different surfaces. Firstly, a single layer of nanoparticles was deposited onto the surface provided by the gold-coated quartz resonator functionalized with sodium 3-mercapto propanesulfonate (3-MPS). Secondly, the layer-by-layer (LbL) technique was used to build multilayers in which the CoFe(2)O(4) nanoparticle-based layer alternates with the sodium sulfonated polystyrene (PSS) layer. The adsorption experiments were conducted by modulating the number of adsorbed CoFe(2)O(4)/PSS bilayers (n) and/or by changing the CoFe(2)O(4) nanoparticle concentration while suspended as a stable colloidal dispersion. Adsorption of CoFe(2)O(4) nanoparticles onto the 3-MPS-functionalized surface follows perfectly a first order kinetic process in a wide range (two orders of magnitude) of nanoparticle concentrations. These data were used to assess the equilibrium constant and the adsorption free energy. Alternatively, the Langmuir adsorption constant was obtained while analyzing the isotherm data at the equilibrium. Adsorption of CoFe(2)O(4) nanoparticles while growing multilayers of CoFe(2)O(4)/PSS was conducted using colloidal suspensions with CoFe(2)O(4) concentration in the range of 10(-8) to 10(-6) (moles of cobalt ferrite per litre) and for different numbers of cycles n = 1, 3, 5, and 10. We found the adsorption of CoFe(2)O(4) nanoparticles within the CoFe(2)O(4)/PSS bilayers perfectly following a first order kinetic process, with the characteristic rate constant growing with the increase of CoFe(2)O(4) nanoparticle concentration and decreasing with the rise of the number of LbL cycles (n). Additionally, atomic force microscopy was employed for assessing the LbL film roughness and thickness. We found the film

  17. Quartz crystal microbalance: a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface.

    Science.gov (United States)

    Marx, Kenneth A

    2003-01-01

    The quartz crystal microbalance (QCM) is a simple, cost effective, high-resolution mass sensing technique, based upon the piezoelectric effect. As a methodology, the QCM evolved a solution measurement capability in largely analytical chemistry and electrochemistry applications due to its sensitive solution-surface interface measurement capability. The technique possesses a wide detection range. At the low mass end, it can detect monolayer surface coverage by small molecules or polymer films. At the upper end, it is capable of detecting much larger masses bound to the surface. These can be complex arrays of biopolymers and biomacromolecules, even whole cells. In addition, the QCM can provide information about the energy dissipating properties of the bound surface mass. Another important and unique feature of the technique is the ability to measure mass and energy dissipation properties of films while simultaneously carrying out electrochemistry on solution species or upon film systems bound to the upper electrode on the oscillating quartz crystal surface. These measurements can describe the course of electropolymerization of a film or can reveal ion or solute transport within a film during changes in the film environment or state, including the oxidation state for an electroactive film driven by the underlying surface potential. The past decade has witnessed an explosive growth in the application of the QCM technique to the study of a wide range of molecular systems at the solution-surface interface, in particular, biopolymer and biochemical systems. In this report, we start with a brief historical and technical overview. Then we discuss the application of the QCM technique to measurements involving micellar systems, self-assembling monolayers and their phase transition behavior, molecularly imprinted polymers, chemical sensors, films formed using the layer-by-layer assembly technique, and biopolymer films and point out the utility of the electrochemical

  18. On the electric double-layer structure at carbon electrode/organic electrolyte solution interface analyzed by ac impedance and electrochemical quartz-crystal microbalance responses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-Tae; Egashira, Minato; Yoshimoto, Nobuko [Department of Applied Chemistry, Graduate School of Science and Engineering, Yamaguchi University, 2-16-1, Tokiwadai, Ube 755-8611 (Japan); Morita, Masayuki, E-mail: morita@yamaguchi-u.ac.jp [Department of Applied Chemistry, Graduate School of Science and Engineering, Yamaguchi University, 2-16-1, Tokiwadai, Ube 755-8611 (Japan)

    2011-08-30

    Highlights: {center_dot} We monitored resonance frequency change of smooth surface carbon electrode to determine mass changes during electrochemical polarization.{center_dot} This was done from viewpoints of ensuring the electric double-layer structure in organic electrolytes.{center_dot} Clear difference was observed in the mass changes among the electrolyte composition.{center_dot} It were related with differences in the double-layer capacitance at carbon. - Abstract: ac impedance and electrochemical quartz crystal microbalance (EQCM) techniques have been applied to analyze the structure of electric double-layer formed at carbon/organic electrolyte solution interface using a sputtered carbon electrode. The mass changes caused by electrochemical adsorption (accumulation) of ions have been estimated in the solutions of propylene carbonate (PC) dissolving tetrafluoroborate (BF{sub 4}{sup -}) salts of lithium (Li{sup +}), tetraethylammonium (TEA{sup +}) and tetra-n-butylammonium (TBA{sup +}) cations. The observed mass changes during the cathodic polarization in the solutions containing TEA{sup +} and TBA{sup +} were well consistent with those expected by the calculation based on mono-layer adsorption of the cations with giving the consideration to the surface roughness. On the other hand, the mass change observed in the solution containing Li{sup +} salt showed that the solvation of Li{sup +} with three or four molecules of PC would be the charge compensation species at the interface. Comparison of the quantity of the electricity passed during the EQCM measurements with that from theoretical calculation with simple Helmholtz-layer model revealed that the major part of the double-layer capacitance would be based on the electrostatic polarization of the solvent molecule directly adsorbed at the carbon surface.

  19. Investigation of Bovine Serum Albumin (BSA Attachment onto Self-Assembled Monolayers (SAMs Using Combinatorial Quartz Crystal Microbalance with Dissipation (QCM-D and Spectroscopic Ellipsometry (SE.

    Directory of Open Access Journals (Sweden)

    Hanh T M Phan

    Full Text Available Understanding protein adsorption kinetics to surfaces is of importance for various environmental and biomedical applications. Adsorption of bovine serum albumin to various self-assembled monolayer surfaces including neutral and charged hydrophilic and hydrophobic surfaces was investigated using in-situ combinatorial quartz crystal microbalance with dissipation and spectroscopic ellipsometry. Adsorption of bovine serum albumin varied as a function of surface properties, bovine serum albumin concentration and pH value. Charged surfaces exhibited a greater quantity of bovine serum albumin adsorption, a larger bovine serum albumin layer thickness, and increased density of bovine serum albumin protein compared to neutral surfaces at neutral pH value. The quantity of adsorbed bovine serum albumin protein increased with increasing bovine serum albumin concentration. After equilibrium sorption was reached at pH 7.0, desorption of bovine serum albumin occurred when pH was lowered to 2.0, which is below the isoelectric point of bovine serum albumin. Our data provide further evidence that combinatorial quartz crystal microbalance with dissipation and spectroscopic ellipsometry is a sensitive analytical tool to evaluate attachment and detachment of adsorbed proteins in systems with environmental implications.

  20. An erosion sensor based on a quartz crystal microbalance for quantitative determination of the cleaning efficiency in an ultrasonic vessel.

    Science.gov (United States)

    Jüschke, M; Koch, C; Dreyer, T

    2014-09-01

    The efficiency of ultrasonic cleaning vessels cannot be measured directly in an easy way. In the presented work, a sensor is developed which quantitatively measures the ablation of a test layer. The sensor element is a quartz crystal which is coated with a sacrificial layer. Small changes in mass of this layer can be measured by a frequency shift of the crystal oscillation. For measurements, a 10 MHz AT-cut quartz crystal was used in a cleaning vessel working at 44.9 kHz. To determine the frequency shift by the ablation of the test layer, the quartz crystal was driven by a frequency generator sweeping the frequency in the range of the resonance frequency and a characteristic frequency was determined. The test layer which was applied to the quartz crystal consisted of silica microparticles suspended in varnish. In a preliminary experiment using a commercial cleaner it could be shown that significant changes in resonance frequency by cavitation effect could be detected. The initial frequency shift of the sacrificial layer is reproducible within 10%. The test layer can be adapted to the conditions of the cleaning vessel. By changing the electrical input power of the vessel, a threshold in the cavitation erosion was found.

  1. On the lipid-bacterial protein interaction studied by quartz crystal microbalance with dissipation, transmission electron microscopy and atomic force microscopy

    CERN Document Server

    Delcea, Mihaela; Pum, Dietmar; Sleytr, Uwe Bernd; Toca-Herrera, Jose Luis

    2009-01-01

    The interaction between the bacterial S-protein SbpA on different types of lipid membranes has been studied using atomic force microscopy, transmission electron microscopy, and quartz crystal microbalance with dissipation. On one hand, It has been found that the bacterial forms two dimensional nanocrystals on zwitterionic DOPC bilayers and negatively charged DMPG vesicles adsorbed on mica, on zwitterionic DPPC and charged DPPC/DMPG (1:1) monolayers adsorbed on carbon grids. On the other hand, SbpA protein adsorption took place on zwitterionic DOPC bilayers and DOPC/DOPS (4:1) bilayers, previously adsorbed on silicon supports. SbpA adsorption also took place on DPPC/DOPS (1:1) monolayers adsorbed on carbon grids. Finally, neither SbpA adsorption, nor recrystallization was observed on zwitterionic DMPC vesicles (previously adsorbed on polyelectrolyte multilayers), and on DPPC vesicles supported on silicon.

  2. Development and application of quartz crystal microbalance sensor based on novel molecularly imprinted sol-gel polymer for rapid detection of histamine in foods.

    Science.gov (United States)

    Dai, Jie; Zhang, Yan; Pan, Mingfei; Kong, Lingjie; Wang, Shuo

    2014-06-11

    To rapidly detect histamine (HA) in foods, a novel material for HA-specific recognition was synthesized by a sol-gel process and coated on a quartz crystal microbalance (QCM) sensor. The Scatchard model was used to evaluate the adsorption performance of the material; high affinity for HA was demonstrated. Based on QCM frequency change, the sensor exhibited linear behavior for HA concentrations of 0.11 × 10(-2) to 4.45 × 10(-2) mg L(-1), a detection limit of 7.49 × 10(-4) mg kg(-1) (S/N = 3), high selectivity for HA (selectivity coefficient >4) compared with structural analogues, good reproducibility, and long-term stability. The sensor was used to determine the concentration of HA in spiked fish products; the recovery values were satisfactory (93.2-100.4%) and compared well with those obtained by high-performance liquid chromatography (correlation coefficient, r(2) = 0.9965).

  3. The impact of water and hydrocarbon concentration on the sensitivity of a polymer-based quartz crystal microbalance sensor for organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Pejcic, Bobby, E-mail: Bobby.Pejcic@csiro.au [CSIRO, Earth Science and Resource Engineering, PO Box 1130, Bentley, WA 6102 (Australia); Crooke, Emma [CSIRO, Earth Science and Resource Engineering, PO Box 1130, Bentley, WA 6102 (Australia); Doherty, Cara M.; Hill, Anita J. [CSIRO, Materials Science and Engineering, Locked Bag 33, Clayton Sth MDC, Vic 3169 (Australia); Myers, Matthew [CSIRO, Earth Science and Resource Engineering, PO Box 1130, Bentley, WA 6102 (Australia); University of Western Australia, School of Biomedical, Biomolecular and Chemical Sciences, Crawley, WA 6009 (Australia); Qi, Xiubin; Ross, Andrew [CSIRO, Earth Science and Resource Engineering, PO Box 1130, Bentley, WA 6102 (Australia)

    2011-10-03

    Highlights: {yields} The response of a polymer coated QCM sensor is affected by water soaking time. {yields} Polymer-water interfacial processes influence the QCM sensitivity for hydrocarbons. {yields} The QCM sensitivity of high Tg polymer films is affected by plasticization processes. - Abstract: Long-term environmental monitoring of organic compounds in natural waters requires sensors that respond reproducibly and linearly over a wide concentration range, and do not degrade with time. Although polymer coated piezoelectric based sensors have been widely used to detect hydrocarbons in aqueous solution, very little information exists regarding their stability and suitability over extended periods in water. In this investigation, the influence of water aging on the response of various polymer membranes [polybutadiene (PB), polyisobutylene (PIB), polystyrene (PS), polystyrene-co-butadiene (PSB)] was studied using the quartz crystal microbalance (QCM). QCM measurements revealed a modest increase in sensitivity towards toluene for PB and PIB membranes at concentrations above 90 ppm after aging in water for 4 days. In contrast, the sensitivity of PS and PSB coated QCM sensors depended significantly on the toluene concentration and increased considerably at concentrations above 90 ppm after aging in water for 4 days. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) showed that there is a change in the sorption mechanism at higher toluene levels for PS and PSB. Positron annihilation lifetime spectroscopy (PALS) studies were performed to investigate the free volume properties of all polymers and to monitor any changes in the free volume size and distribution due to water and toluene exposure. The PALS did not detect any considerable variation in the free volume properties of the polymer films as a function of solution composition and soaking time, implying that viscoelastic and/or interfacial processes (i.e. surface area changes) are probably

  4. Quartz Crystal Microbalance Coated with Sol-gel-derived Thin Films as Gas Sensor for NO Detection

    Directory of Open Access Journals (Sweden)

    S. J. O’Shea

    2003-10-01

    Full Text Available This paper presents the possibilities and properties of Indium tin oxide (ITO-covered quartz crystal as a NOx toxic gas-sensor. The starting sol-gel solution was prepared by mixing indium chloride dissolved in acetylacetone and tin chloride dissolved in ethanol (0-20% by weight. The ITO thin films were deposited on the gold electrodes of quartz crystal by spin-coating technique and subsequently followed a standard photolithography to pattern the derived films to ensure all sensors with the same sensing areas. All heat treatment processes were controlled below 500°C in order to avoid the piezoelectric characteristics degradation of quartz crystal (Quartz will lose its piezoelectricity at ~573°C due to the phase change from α to β. The electrical and structural properties of ITO thin films were characterized with Hall analysis system, TG/DTA, XRD, XPS, SEM and etc. The gas sensor had featured with ITO thin films of ~100nm as the receptor to sense the toxic gas NO and quartz crystal with frequency of 10MHz as the transducer to transfer the surface reactions (mass loading, etc into the frequency shift. A homemade setup had been employed to measure the sensor response under the static mode. The experimental results had indicated that the ITO-coated QCM had a good sensitivity for NO gas, ~12Hz/100ppm within 5mins. These results prove that the ITO-covered quartz crystals are usable as a gas sensor and as an analytical device.

  5. Use of quartz crystal microbalance to study the effect of chloride, sulphate and magnesium ions on the scaling rate; Apport de la microbalance a quartz dans l'etude de l'influence des ions sulfate, chlorure et magnesium sur la cinetique d'entartrage

    Energy Technology Data Exchange (ETDEWEB)

    Ben Amor, Y.; Triki, E. [Ecole Nationale d' Ingenieurs de Tunis, Unite de Recherche Corrosion et Protection des Metalliques (Tunisia); Bousselmi, I. [Institut National de Recherche Scientifique et Technologique, Lab. des Eaux et Environnement, Hammam-Lif (Tunisia); Sutter, E.; Labbe, J.P.; Fiaud, C. [Universite Pierre et Marie Curie, Lab. de Genie des Procedes Plasmas et Traitements de Surface, 75 - Paris (France)

    2004-07-01

    In this work, an electrochemical quartz crystal microbalance was used to study the effect of chloride, sulphate and magnesium ions on the scaling rate of gold in synthesized water. The chrono-electro-gravimetric results allow the evaluation of the nucleation and crystal growth steps. Infrared analysis of deposits was used to interpret the kinetic data, particularly in SO{sub 4}{sup 2-} and Mg{sup 2+} containing. Threshold effects were identified in each situation and essentially attributed to adsorption phenomena of ions on the metal and/or on the scale layers, as indicated by the influence of electrode potential and concentration of ions in solutions. (authors)

  6. Nucleation and growth of hydroxyapatite on arc-deposited TiO{sub 2} surfaces studied by quartz crystal microbalance with dissipation

    Energy Technology Data Exchange (ETDEWEB)

    Lilja, Mirjam [Division for Nanotechnology and Functional Materials, Department of Engineering Sciences, The Ångström Laboratory, Uppsala University, Box 534, 75121 Uppsala (Sweden); Sandvik Coromant Sverige AB, Lerkrogsvägen 19, 12680 Stockholm (Sweden); Butt, Umer [Sandvik Coromant Sverige AB, Lerkrogsvägen 19, 12680 Stockholm (Sweden); Berzelii Centre EXSELENT on Porous Materials and Department of Materials and Environmental Chemistry, Arrhenius Laboratory, Stockholm University, 114 18 Stockholm (Sweden); Shen, Zhijian [Berzelii Centre EXSELENT on Porous Materials and Department of Materials and Environmental Chemistry, Arrhenius Laboratory, Stockholm University, 114 18 Stockholm (Sweden); Bjöörn, Dorota, E-mail: dorota.bjoorn@sandvik.com [Sandvik Coromant Sverige AB, Lerkrogsvägen 19, 12680 Stockholm (Sweden)

    2013-11-01

    Understanding of nucleation and growth kinetics of biomimetically deposited hydroxyapatite (HA) on crystalline TiO{sub 2} surfaces is important with respect to the application and performance of HA as functional implant coatings. Arc-evaporation was used to deposit TiO{sub 2} coatings dominated by anatase phase, rutile phase or their mixtures. Subsequent formation of HA from phosphate buffered saline solution (PBS) was investigated in real-time using in situ quartz crystal microbalance with dissipation technique (QCM-D). Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were employed to characterize the presence, morphology and crystal structure of TiO{sub 2} coatings and the formed HA. Increasing temperature of the PBS, increasing flow rate and applying a higher ion concentration in solution were found to accelerate HA nucleation process and hence affect growth kinetics. Lower PBS temperature resulted in the formation of HA coatings with flake-like morphology and increasing HA porosity. All TiO{sub 2} coatings under study enabled HA formation at body temperature, while in contrast Ti reference surfaces only supported HA nucleation and growth at elevated temperatures. QCM-D technique is a powerful tool for studying the impact of process parameters during biomimetic coating deposition on coating structure evolution in real time and provides valuable information for understanding, optimizing as well as tailoring the biomimetic HA growth processes.

  7. Protein adsorption behaviors on chitosan/poly(ε-caprolactone) blend films studied by quartz crystal microbalance with dissipation monitoring(QCM-D)

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Chitosan/poly(ε-caprolactone) (PCL) blend films in different mass ratios were prepared using the chitosan/PCL mixture solutions in 80 vol.-% acetic acid by spin coating. Their surface micromorphologies were assessed by atomic force microscopy (AFM). It was found that the micromorphology of chitosan/PCL blend films was in large extent related to the mass ratio of chitosan. 25 wt% chitosan/PCL blend film presented microphase separation. The protein adsorption of bovine serum albumin (BSA) onto chitosan/PCL blend films was investigated by using quartz crystal microbalance with dissipation monitoring (QCM-D) in real time. The results suggested that the amount of adsorbed BSA on the chitosan/PCL blend films decreased with the addition of chitosan, but the structure and viscoelastic properties of the adsorbed BSA layers were greatly affected by the surface micromorphology of chitosan/PCL blend films. BSA absorbed on the 25 wt% chitosan/PCL blend film with microphase separa- tion showed larger adsorption reversibility, and preferred to form a loose, dissipative layer in comparison with those on other chitosan/PCL blend films without microphase separation.

  8. Investigation of photoelectrochemical oxidation of Fe{sup 2+} ions on porous nanocrystalline TiO{sub 2} electrodes using electrochemical quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Si Shihui; Huang Kelong; Wang Xiaoguang; Huang Mingzhi; Chen Hanfang

    2002-12-20

    The photoelectrochemical oxidation of Fe{sup 2+} ions on porous nanocrystalline TiO{sub 2} electrodes was investigated using in situ electrochemical quartz crystal microbalance (QCM). It was found that the adsorption of Fe{sup 2+} ions at the surface of TiO{sub 2} electrodes strongly depended on the pH of the solution, and that the saturated amount of adsorbed Fe{sup 2+} ions was approximately 4.4 ions nm{sup -2} at pH 4. The protons produced in photochemical reactions could cause the release of adsorbed Fe{sup 2+} ions from TiO{sub 2} surface, therefore, the frequency of QCM increased at the initial stage of illumination, during which the direct oxidation of adsorbed Fe{sup 2+} ions by photogenerated holes was dominant. When the frequency decreased, the major reaction was the photoelectrochemical deposition of Fe{sub 2}O{sub 3} from the bulk solution via a hydroxyl radical-mediated oxidation pathway, whose efficiency depended on the Fe{sup 2+} ion concentration.

  9. A quick responding quartz crystal microbalance sensor array based on molecular imprinted polyacrylic acids coating for selective identification of aldehydes in body odor.

    Science.gov (United States)

    Jha, Sunil K; Hayashi, Kenshi

    2015-03-01

    In present work, a novel quartz crystal microbalance (QCM) sensor array has been developed for prompt identification of primary aldehydes in human body odor. Molecularly imprinted polymers (MIP) are prepared using the polyacrylic acid (PAA) polymer matrix and three organic acids (propenoic acid, hexanoic acid and octanoic acid) as template molecules, and utilized as QCM surface coating layer. The performance of MIP films is characterized by 4-element QCM sensor array (three coated with MIP layers and one with pure PAA for reference) dynamic and static responses to target aldehydes: hexanal, heptanal, and nonanal in single, binary, and tertiary mixtures at distinct concentrations. The target aldehydes were selected subsequent to characterization of body odor samples with solid phase-micro extraction gas chromatography mass spectrometer (SPME-GC-MS). The hexanoic acid and octanoic acid imprinted PAA exhibit fast response, and better sensitivity, selectivity and reproducibility than the propenoic acid, and non-imprinted PAA in array. The response time and recovery time for hexanoic acid imprinted PAA are obtained as 5 s and 12 s respectively to typical concentrations of binary and tertiary mixtures of aldehydes using the static response. Dynamic sensor array response matrix has been processed with principal component analysis (PCA) for visual, and support vector machine (SVM) classifier for quantitative identification of target odors. Aldehyde odors were identified successfully in principal component (PC) space. SVM classifier results maximum recognition rate 79% for three classes of binary odors and 83% including single, binary, and tertiary odor classes in 3-fold cross validation.

  10. Protein adsorption behaviors on chitosan/poly(ε-caprolactone)blend films studied by quartz crystal microbalance with dissipation monitoring (QCM-D)

    Institute of Scientific and Technical Information of China (English)

    ZENG Rong; ZHANG Yi; LIANG ZhiHong; TU Mei; ZHOU ChangRen

    2009-01-01

    Chitosan/poly(ε-caprolactone)(PCL)blend films in different mass ratios were prepared using the chitosan/PCL mixture solutions in 80 vol.-% acetic acid by spin coating.Their surface micromorphologies were assessed by atomic force microscopy(AFM).It was found that the micromorphology of chitosan/PCL blend films was in large extent related to the mass ratio of chitosan.25 wt% chitosan/PCL blend film presented microphase separation.The protein adsorption of bovine serum albumin(BSA)onto chitosan/PCL blend films was investigated by using quartz crystal microbalance with dissipation monitoring(QCM-D)in real time.The results suggested that the amount of adsorbed BSA on the chitosan/PCL blend films decreased with the addition of chitosan,but the structure and viscoelastic properties of the adsorbed BSA layers were greatly affected by the surface micromorphology of chitosan/PCL blend films.BSA absorbed on the 25 wt% chitosan/PCL blend film with microphase separation showed larger adsorption reversibility,and preferred to form a loose,dissipative layer in comparison with those on other chitosan/PCL blend films without microphase separation.

  11. Assessment of DNA binding to human Rad51 protein by using quartz crystal microbalance and atomic force microscopy: effects of ADP and BRC4-28 peptide inhibitor.

    Science.gov (United States)

    Esnault, Charles; Renodon-Cornière, Axelle; Takahashi, Masayuki; Casse, Nathalie; Delorme, Nicolas; Louarn, Guy; Fleury, Fabrice; Pilard, Jean-François; Chénais, Benoît

    2014-12-01

    The interaction of human Rad51 protein (HsRad51) with single-stranded deoxyribonucleic acid (ssDNA) was investigated by using quartz crystal microbalance (QCM) monitoring and atomic force microscopy (AFM) visualization. Gold surfaces for QCM and AFM were modified by electrografting of the in situ generated aryldiazonium salt from the sulfanilic acid to obtain the organic layer Au-ArSO3 H. The Au-ArSO3 H layer was activated by using a solution of PCl5 in CH2 Cl2 to give a Au-ArSO2 Cl layer. The modified surface was then used to immobilize long ssDNA molecules. The results obtained showed that the presence of adenosine diphosphate promotes the protein autoassociation rather than nucleation around DNA. In addition, when the BRC4-28 peptide inhibitor was used, both QCM and AFM confirmed the inhibitory effect of BRC4-28 toward HsRad51 autoassociation. Altogether these results show the suitability of this modified surface to investigate the kinetics and structure of DNA-protein interactions and for the screening of inhibitors.

  12. Quartz crystal microbalance with dissipation and microscale thermophoresis as tools for investigation of protein complex formation between thymidylate synthesis cycle enzymes.

    Science.gov (United States)

    Antosiewicz, Anna; Senkara, Elżbieta; Cieśla, Joanna

    2015-02-15

    Thymidylate synthase (TS) and dihydrofolate reductase (DHFR) play essential role in DNA synthesis, repair and cell division by catalyzing two subsequent reactions in thymidylate biosynthesis cycle. The lack of either enzyme leads to thymineless death of the cell, therefore inhibition of the enzyme activity is a common and successful tool in cancer chemotherapy and treatment of other diseases. However, the detailed mechanism of thymidylate synthesis cycle, especially the interactions between cycle enzymes and its role remain unknown. In this paper we are the first to show that human TS and DHFR enzymes form a strong complex which might be essential for DNA synthesis. Using two unique biosensor techniques, both highly sensitive to biomolecular interactions, namely quartz crystal microbalance with dissipation monitoring (QCM-D) and microscale thermophoresis (MST) we have been able to determine DHFR-TS binding kinetic parameters such as the Kd value being below 10 µM (both methods), k(on) = 0.46 × 10(4) M(-1) s(-1) and k(off) = 0.024 s(-1) (QCM-D). We also calculated Gibbs free energy as in the order of -30 kJ/mol and DHFR/TS molar ratio pointing to binding of 6 DHFR monomers per 1 TS dimer (both methods). Moreover, our data from MST analysis have pointed to positive binding cooperativity in TS-DHFR complex formation. The results obtained with both methods are comparable and complementary.

  13. Particle Characterization for a Protein Drug Product Stored in Pre-Filled Syringes Using Micro-Flow Imaging, Archimedes, and Quartz Crystal Microbalance with Dissipation.

    Science.gov (United States)

    Zheng, Songyan; Puri, Aastha; Li, Jinjiang; Jaiswal, Archana; Adams, Monica

    2017-01-01

    Micro-flow imaging (MFI) has been used for formulation development for analyzing sub-visible particles. Archimedes, a novel technique for analyzing sub-micron particles, has been considered as an orthogonal method to currently existing techniques. This study utilized these two techniques to investigate the effectiveness of polysorbate (PS-80) in mitigating the particle formation of a therapeutic protein formulation stored in silicone oil-coated pre-filled syringes. The results indicated that PS-80 prevented the formation of both protein and silicone oil particles. In the case of protein particles, PS-80 might involve in the interactions with the hydrophobic patches of protein, air bubbles, and the stressed surfaces of silicone oil-coated pre-filled syringes. Such interactions played a role in mitigating the formation of protein particles. Subsequently, quartz crystal microbalance with dissipation (QCM-D) was utilized to characterize the interactions associated with silicone oil, protein, and PS-80 in the solutions. Based on QCM-D results, we proposed that PS-80 likely formed a layer on the interior surfaces of syringes. As a result, the adsorbed PS-80 might block the leakage of silicone oil from the surfaces to solution so that the silicone oil particles were mitigated at the presence of PS-80. Overall, this study demonstrated the necessary of utilizing these three techniques cooperatively in order to better understand the interfacial role of PS-80 in mitigating the formation of protein and silicone oil particles.

  14. Mucoadhesion vs mucus permeability of thiolated chitosan polymers and their resulting nanoparticles using a quartz crystal microbalance with dissipation (QCM-D).

    Science.gov (United States)

    Oh, Sejin; Borrós, Salvador

    2016-11-01

    The aim of this present study was to evaluate the combination properties between mucoadhesion/mucus permeability of thiolated chitosans (TC) and their resulting nanoparticles using a quartz crystal microbalance with dissipation (QCM-D). The QCM-D experiments were conducted at pH 4 or 6.8 to assess the interaction between thiolated polymers, with low (TCL), medium (TCM) and high (TCH) contents of free thiol groups, and native porcine gastric mucin (NPGM). TCL was chosen for further carriers as it showed higher permeability into the NPGM layer compared to TCM and TCH. In this study, we describe a formulation of a novel carrier comprised by positively charged TCL, negatively charged DNA and degradable oligopeptide-modified poly(β-amino ester)s (PBAEs), which were employed in order to approach for tuning particle size and surface charge of complexes. TCL/PBAE complexes with or without DNA were characterized using dynamic light scattering. Mechanism of adsorption or permeation of the TCL/PBAE/DNA complexes into the NPGM barrier was investigated with QCM-D, which is a highly sensitive technique for studying nanomechanical (viscoelastic) changes of the substrates. This work might provide that the QCM-D technique would be a promising method to monitor the dynamic behaviour between complexes and NPGM.

  15. Application of a quartz crystal microbalance to the study of copper corrosion in acid solution inhibited by triazole-iodide protective films

    Energy Technology Data Exchange (ETDEWEB)

    Jope, D.; Sell, J.; Pickering, H.W.; Weil, K.G. [Pennsylvania State Univ., University Park, PA (United States). Dept. of Materials Science and Engineering

    1995-07-01

    When one uses one side of a quartz crystal microbalance as the working electrode in electrochemical experiments, mass changes can be monitored continuously with a sensitivity of a few nanograms per square centimeter. In this study the working electrode consisted of electrolytically deposited copper, exposed to 0.1M sodium sulfate at pH 3, open to the atmosphere and in some cases containing H{sub 2}O{sub 2}. Upon addition of one of the inhibitors, benzotriazole (BTA), tolyltriazole (TTA), carboxy-benzotriazole (CBT), or these inhibitors plus potassium iodide, the rate of frequency change decreases markedly. After removal of the inhibitors from the corrosive medium by fast solution exchange there is a marked continuing protective effect of the inhibitor films in the cases of BTA + KI and TTA + KI with the latter being the most stable and protective of all of the films. The results were qualitatively the same in the more corrosive solution containing H{sub 2}O{sub 2}.

  16. Characterization of the native and denatured herceptin by enzyme linked immunosorbent assay and quartz crystal microbalance using a high-affinity single chain fragment variable recombinant antibody.

    Science.gov (United States)

    Shang, Yuqin; Mernaugh, Ray; Zeng, Xiangqun

    2012-10-02

    Herceptin/Trastuzumab is a humanized IgG1κ light chain antibody used to treat some forms of breast cancer. A phage-displayed recombinant antibody library was used to obtain a single chain fragment variable (scFv, designated 2B4) to a linear synthetic peptide representing Herceptin's heavy chain CDR3. Enzyme linked immunosorbent assays (ELISAs) and piezoimmunosensor/quartz crystal microbalance (QCM) assays were used to characterize 2B4-binding activity to both native and heat denatured Herceptin. The 2B4 scFv specifically bound to heat denatured Herceptin in a concentration dependent manner over a wide (35-220.5 nM) dynamic range. Herceptin denatures and forms significant amounts of aggregates when heated. UV-vis characterization confirms that Herceptin forms aggregates as the temperature used to heat Herceptin increases. QCM affinity assay shows that binding stoichiometry between 2B4 scFv and Herceptin follows a 1:2 relationship proving that 2B4 scFv binds strongly to the dimers of heat denatured Herceptin aggregates and exhibits an affinity constant of 7.17 × 10(13) M(-2). The 2B4-based QCM assay was more sensitive than the corresponding ELISA. Combining QCM with ELISA can be used to more fully characterize nonspecific binding events in assays. The potential theoretical and clinical implications of these results and the advantages of the use of QCM to characterize human therapeutic antibodies in samples are also discussed.

  17. Electrochemistry, surface plasmon resonance, and quartz crystal microbalance: an associative study on cytochrome c adsorption on pyridine tail-group monolayers on gold.

    Science.gov (United States)

    Paulo, Tércio de F; de Sousa, Ticyano P; de Abreu, Dieric S; Felício, Nathalie H; Bernhardt, Paul V; Lopes, Luiz G de F; Sousa, Eduardo H S; Diógenes, Izaura C N

    2013-07-25

    Quartz crystal microbalance (QCM), surface plasmon resonance (SPR), and electrochemistry techniques were used to study the electron-transfer (ET) reaction of cytochrome c (Cyt c) on gold surfaces modified with thionicotinamide, thioisonicotinamide, 4-mercaptopyridine, 5-(4-pyridyl)-1,3,4-oxadiazole-2-thiol, 5-phenyl-1,3,4-oxadiazole-2-thiol, 4,4'-bipyridine, and 4,4'-dithiopyridine. The electrochemical results showed that the ET process is complex, being chiefly diffusional with steps depending on the orientation of the pyridine or phenyl tail group of the modifiers. The correlation between the electrochemical results and those acquired by SPR and QCM indicated the presence of an adlayer of Cyt c adsorbed on the thiolate SAMs. This adlayer, although being not electroactive, is essential to assess the ET reaction of Cyt c in solution. The results presented in this work are consistent with the statement (Feng, Z. Q.; Imabayashi, S.; Kakiuchi, T.; Niki, K. J. Electroanal. Chem. 1995, 394, 149-154) that the ET reaction of Cyt c can be explained in terms of the through-bond tunneling mechanism.

  18. Electrochemical quartz crystal microbalance studies on enzymatic specific activity and direct electrochemistry of immobilized glucose oxidase in the presence of sodium dodecyl benzene sulfonate and multiwalled carbon nanotubes.

    Science.gov (United States)

    Su, Yuhua; Xie, Qingji; Chen, Chao; Zhang, Qingfang; Ma, Ming; Yao, Shouzhuo

    2008-01-01

    The electrochemical quartz crystal microbalance (EQCM) technique was utilized to monitor in situ the adsorption of glucose oxidase (GOD) and the mixture of GOD and sodium dodecyl benzene sulfonate (SDBS) onto Au electrodes with and without modification of multiwalled carbon nanotubes (MWCNTs) or SDBS/MWCNTs composite, and the relationship between enzymatic specific activity (ESA) and direct electrochemistry of the immobilized GOD was quantitatively evaluated for the first time. Compared with the bare gold electrode at which a little GOD was adsorbed and the direct electrochemistry of the adsorbed GOD was negligible, the amount and electroactivity of adsorbed GOD were greatly enhanced when the GOD was mixed with SDBS and then adsorbed onto the SDBS/MWCNTs modified Au electrode. However, the ESA of the adsorbed GOD was fiercely decreased to only 16.1% of the value obtained on the bare gold electrode, and the portion of adsorbed GOD showing electrochemical activity exhibited very low enzymatic activity, demonstrating that the electroactivity and ESA of immobilized GOD responded oppositely to the presence of MWCNTs and SDBS. The ESA results obtained from the EQCM method were well supported by conventional UV-vis spectrophotometry. The direct electrochemistry of redox proteins including enzymes as a function of their biological activities is an important concern in biotechnology, and this work may have presented a new and useful protocol to quantitatively evaluate both the electroactivity and ESA of trace immobilized enzymes, which is expected to find wider applications in biocatalysis and biosensing fields.

  19. Quartz crystal microbalance study of ionic strength and pH-dependent polymer conformation and protein adsorption/desorption on PAA, PEO, and mixed PEO/PAA brushes.

    Science.gov (United States)

    Delcroix, M F; Demoustier-Champagne, S; Dupont-Gillain, C C

    2014-01-14

    The conformation of polymer chains grafted on a substrate influences protein adsorption. In a previous study, adsorption/desorption of albumin was demonstrated on mixed poly(ethylene oxide) (PEO)/poly(acrylic acid) (PAA) brushes, triggered by solutions of adequate pH and ionic strength (I). In the present work, homolayers of PEO or PAA are submitted to saline solutions with pH from 3 to 9 and I from 10(-5) to 10(-1) M, and their conformation is evaluated in real time using quartz crystal microbalance with dissipation monitoring (QCM-D). Shrinkage/swelling of PAA chains and hydration and salt condensation in the brush are evidenced. The adsorption of human serum albumin (HSA) onto such brushes is also monitored in these different saline solutions, leading to a deep understanding of the influence of polymer chain conformation, modulated by pH and I, on protein adsorption. A detailed model of the conformation of PEO/PAA mixed brushes depending on pH and I is then proposed, providing a rationale for the identification of conditions for the successive adsorption and desorption of proteins on such mixed brushes. The adsorption/desorption of albumin on PEO/PAA is demonstrated using QCM-D.

  20. Detection of Cry2A Protein Based on Quartz Crystal Microbalance Technique%Cry2A蛋白的石英晶体微天平检测

    Institute of Scientific and Technical Information of China (English)

    杜方; 黄新; 纪淑娟

    2014-01-01

    目的:建立检测苏云金芽孢杆菌Cry2A蛋白的石英晶体微天平(quartz crystal microbalance,QCM)传感方法.方法:根据抗原抗体相互作用原理,利用QCM技术,在金片表面修饰抗原所对应的单克隆抗体,对苏云金芽孢杆菌Cry2A蛋白进行检测研究.结果:该方法灵敏度达到1μg/mL,特异性好、重复性高.结论:该方法有利于为苏云金芽孢杆菌蛋白检测提供新思路,可以应用到实际样品的检测,在农产品转基因检测和进出口检验检疫中具有很好的应用前景.

  1. 1-Butyl-3-Methylimidazolium Tetrafluoroborate Film as a Highly Selective Sensing Material for Non-Invasive Detection of Acetone Using a Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Wenyan Tao

    2017-01-01

    Full Text Available Breath acetone serves as a biomarker for diabetes. This article reports 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4], a type of room temperature ionic liquid (RTIL, as a selective sensing material for acetone. The RTIL sensing layer was coated on a quartz crystal microbalance (QCM for detection. The sensing mechanism is based on a decrease in viscosity and density of the [bmim][BF4] film due to the solubilization of acetone leading to a positive frequency shift in the QCM. Acetone was detected with a linear range from 7.05 to 750 ppmv. Sensitivity and limit of detection were found to be 3.49 Hz/ppmv and 5.0 ppmv, respectively. The [bmim][BF4]-modified QCM sensor demonstrated anti-interference ability to commonly found volatile organic compounds in breath, e.g., isoprene, 1,2-pentadiene, d-limonene, and dl-limonene. This technology is useful for applications in non-invasive early diabetic diagnosis.

  2. 1-Butyl-3-Methylimidazolium Tetrafluoroborate Film as a Highly Selective Sensing Material for Non-Invasive Detection of Acetone Using a Quartz Crystal Microbalance

    Science.gov (United States)

    Tao, Wenyan; Lin, Peng; Liu, Sili; Xie, Qingji; Ke, Shanming; Zeng, Xierong

    2017-01-01

    Breath acetone serves as a biomarker for diabetes. This article reports 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4]), a type of room temperature ionic liquid (RTIL), as a selective sensing material for acetone. The RTIL sensing layer was coated on a quartz crystal microbalance (QCM) for detection. The sensing mechanism is based on a decrease in viscosity and density of the [bmim][BF4] film due to the solubilization of acetone leading to a positive frequency shift in the QCM. Acetone was detected with a linear range from 7.05 to 750 ppmv. Sensitivity and limit of detection were found to be 3.49 Hz/ppmv and 5.0 ppmv, respectively. The [bmim][BF4]-modified QCM sensor demonstrated anti-interference ability to commonly found volatile organic compounds in breath, e.g., isoprene, 1,2-pentadiene, d-limonene, and dl-limonene. This technology is useful for applications in non-invasive early diabetic diagnosis. PMID:28117697

  3. Direct measurement of gas solubilities in polymers with a high-pressure microbalance

    DEFF Research Database (Denmark)

    von Solms, Nicolas; Nielsen, Johannes Kristoffer; Hassager, Ole

    2004-01-01

    for methane, for which negative deviations from Henry's law behavior were observed. The diffusion coefficients for each of the gases in the polymer were also measured with the balance, although the uncertainty was greater than for the solubility measurements. (C) 2003 Wiley Periodicals, Inc. J Appl Polyrn Sci...

  4. An oscillating microbalance for meteorological measurements of ice and volcanic ash accumulation from a weather balloon platform

    Science.gov (United States)

    Airey, Martin; Harrison, Giles; Nicoll, Keri; Williams, Paul; Marlton, Graeme

    2017-04-01

    A new, low cost, instrument has been developed for meteorological measurements of the accumulation of ice and volcanic ash that can be readily deployed using commercial radiosondes and weather balloons. It is based on principles used by [1], an instrument originally developed to measure supercooled liquid water profiles in clouds. This new instrument introduces numerous improvements in terms of reduced complexity and cost. It uses the oscillating microbalance principle, whereby a wire vibrating at its natural frequency is subjected to increased loading of the property to be measured. The increase in mass modifies the wire properties such that its natural frequency of oscillation changes. By measuring this frequency, the increase in mass can be inferred and transmitted to a ground base station through the radiosonde's UHF antenna via the PANDORA interface [2], which has been previously developed to provide power and connection to the radiosonde telemetry. The device consists of a simple circuit board controlled by an ATMEGA microcontroller. For calibration, the controller is capable of driving the wire at specified frequencies via excitation by a piezo sounder upon which the wire is mounted. The same piezo sounder is also used during active operation to measure the frequency of the wire in its non-driven state in order to infer the mass change on the wire. A phase-locked loop implemented on the board identifies when resonance occurs and the measured frequency is stable, prompting the microcontroller to send the measurement through the data interface. The device may be used for any application that requires the measurement of incremental mass variation e.g. ice accumulation, frosting, or particle accumulation such as dust and volcanic ash. For the solid particle accumulation, a low temperature, high-tack, adhesive may be applied to the wire prior to deployment to collect the material. In addition, the same instrument may be used for ground-based applications, such as

  5. In-situ etch rate study of Hf{sub x}La{sub y}O{sub z} in Cl{sub 2}/BCl{sub 3} plasmas using the quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Marchack, Nathan; Kim, Taeseung; Chang, Jane P., E-mail: jpchang@seas.ucla.edu [Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, California 90095 (United States); Blom, Hans-Olof [Ångström Laboratory, Uppsala University, P.O. Box 534, SE-751 21 Uppsala (Sweden)

    2015-05-15

    The etch rate of Hf{sub x}La{sub y}O{sub z} films in Cl{sub 2}/BCl{sub 3} plasmas was measured in-situ in an inductively coupled plasma reactor using a quartz crystal microbalance and corroborated by cross-sectional SEM measurements. The etch rate depended on the ion energy as well as the plasma chemistry. In contrast to other Hf-based ternary oxides, the etch rate of Hf{sub x}La{sub y}O{sub z} films was higher in Cl{sub 2} than in BCl{sub 3}. In the etching of Hf{sub 0.25}La{sub 0.12}O{sub 0.63}, Hf appeared to be preferentially removed in Cl{sub 2} plasmas, per surface compositional analysis by x-ray photoelectron spectroscopy and the detection of HfCl{sub 3} generation in mass spectroscopy. These findings were consistent with the higher etch rate of Hf{sub 0.25}La{sub 0.12}O{sub 0.63} than that of La{sub 2}O{sub 3}.

  6. APPLICATION OF QUARTZ CRYSTAL MICROBALANCE IN ATMOSPHERIC CORROSION INVESTIGATION%石英晶体微天平(QCM)在大气腐蚀研究中的应用

    Institute of Scientific and Technical Information of China (English)

    严川伟; 曹楚南; 林海潮

    2001-01-01

    石英晶体微天平(QCM)作为一种高灵敏度的质量检测手段,已经用于金属材料大气腐蚀动力学及其环境因素和缓蚀剂存在的影响规律的研究,对QCM在大气腐蚀研究中的应用进行了综述.%The application of quartz crystal microbalance (QCM) in the study of atmospheric corrosion is reviewed. QCM is available to measure mass changes of a nanngram order and has widely been used for in-situ investigations of atmospheric corrosion. The effects of environmental factors,corrosive gas constituents and gas-phase inhibitors on the atmospheric corrosion mechanism of metal materials have been studied with QCM. In the recent years, the atmospheric corrosivity probe based on QCM techniques has been developed. The characteristics and developing trend of QCM for atmospheric corrosion investigation and monitoring are analyzed and discussed

  7. A living cell quartz crystal microbalance biosensor for continuous monitoring of cytotoxic responses of macrophages to single-walled carbon nanotubes

    Directory of Open Access Journals (Sweden)

    Marx Kenneth A

    2011-01-01

    Full Text Available Abstract Background Numerous engineered nanomaterials (ENMs exist and new ENMs are being developed. A challenge to nanotoxicology and environmental health and safety is evaluating toxicity of ENMs before they become widely utilized. Cellular assays remain the predominant test platform yet these methods are limited by using discrete time endpoints and reliance on organic dyes, vulnerable to interference from ENMs. Label-free, continuous, rapid response systems with biologically meaningful endpoints are needed. We have developed a device to detect and monitor in real time responses of living cells to ENMs. The device, a living cell quartz crystal microbalance biosensor (QCMB, uses macrophages adherent to a quartz crystal. The communal response of macrophages to treatments is monitored continuously as changes in crystal oscillation frequency (Δf. We report the ability of this QCMB to distinguish benign from toxic exposures and reveal unique kinetic information about cellular responses to varying doses of single-walled carbon nanotubes (SWCNTs. Results We analyzed macrophage responses to additions of Zymosan A, polystyrene beads (PBs (benign substances or SWCNT (3-150 μg/ml in the QCMB over 18 hrs. In parallel, toxicity was monitored over 24/48 hrs using conventional viability assays and histological stains to detect apoptosis. In the QCMB, a stable unchanging oscillation frequency occurred when cells alone, Zymosan A alone, PBs alone or SWCNTs without cells at the highest dose alone were used. With living cells in the QCMB, when Zymosan A, PBs or SWCNTs were added, a significant decrease in frequency occurred from 1-6 hrs. For SWCNTs, this Δf was dose-dependent. From 6-18 hrs, benign substances or low dose SWCNT (3-30 μg/ml treatments showed a reversal of the decrease of oscillation frequency, returning to or exceeding pre-treatment levels. Cell recovery was confirmed in conventional assays. The lag time to see the Δf reversal in QCMB plots

  8. Nanoassembled thin film gas sensors. III. Sensitive detection of amine odors using TiO2/poly(acrylic acid) ultrathin film quartz crystal microbalance sensors.

    Science.gov (United States)

    Lee, Seung-Woo; Takahara, Naoki; Korposh, Sergiy; Yang, Do-Hyeon; Toko, Kiyoshi; Kunitake, Toyoki

    2010-03-15

    Quartz crystal microbalance (QCM) gas sensors based on the alternate adsorption of TiO(2) and polyacrilic acid (PAA) were developed for the sensitive detection of amine odors. Individual TiO(2) gel layers could be regularly assembled with a thickness of approximately 0.3 nm by the gas-phase surface sol-gel process (GSSG). The thickness of the poly(acrylic acid) (PAA) layer is dependent on its molecular weight, showing different thicknesses of approximately 0.4 nm for PAA(25) (Mw 250,000) and 0.6-0.8 nm for PAA(400) (Mw 4,000,000). The QCM sensors showed a linear response to ammonia in the concentration range 0.3-15 ppm, depending on the deposition cycle of the alternate TiO(2)/PAA layer. The ammonia binding is based on the acid-base interaction to the free carboxylic acid groups of PAA and the limit of detection (LOD) of the 20-cycle TiO(2)/PAA(400) film was estimated to be 0.1 ppm when exposed to ammonia. The sensor response was very fast and stable in a wide relative humidity (rH) range of 30-70%, showing almost the same frequency changes at a given concentration of ammonia. Sensitivity to n-butylamine and ammonia was higher than to pyridine, which is owing to the difference of molecular weight and basicity of the amine analytes. The alternate TiO(2)/PAA(400) films have a highly effective ability to capture amine odors, and the ambient ammonia concentration of 15 ppm could be condensed up to approximately 20,000 ppm inside the films.

  9. Specific Surface versus Electrochemically Active Area of the Carbon/Polypyrrole Capacitor: Correlation of Ion Dynamics Studied by an Electrochemical Quartz Crystal Microbalance with BET Surface.

    Science.gov (United States)

    Mosch, Heike L K S; Akintola, Oluseun; Plass, Winfried; Höppener, Stephanie; Schubert, Ulrich S; Ignaszak, Anna

    2016-05-10

    Carbon/polypyrrole (PPy) composites are promising electrode materials for energy storage applications such as lightweight capacitors. Although these materials are composed of relatively inexpensive components, there is a gap of knowledge regarding the correlation between surface, porosity, ion exchange dynamics, and the interplay of the double layer capacitance and pseudocapacitance. In this work we evaluate the specific surface area analyzed by the BET method and the area accessible for ions using electrochemical quartz-crystal microbalance (EQCM) for SWCNT/PPy and carbon black Vulcan XC72-R/PPy composites. The study revealed that the polymer has significant influence on the pore size of the composites. Although the BET surface is low for the polypyrrole, the electrode mass change and thus the electrochemical area are large for the polymer-containing electrodes. This indicates that multiple redox active centers in the charged polymer chain are good ion scavengers. Also, for the composite electrodes, the effective charge storage occurs at the polypyrrole-carbon junctions, which are easy to design/multiply by a proper carbon-to-polymer weight ratio. The specific BET surface and electrochemically accessible surface area are both important parameters in calculation of the electrode capacitance. SWCNTs/PPy showed the highest capacitances normalized to the BET and electrochemical surface as compared to the polymer-carbon black. TEM imaging revealed very homogeneous distribution of the nanosized polymer particles onto the CNTs, which facilitates the synergistic effect of the double layer capacitance (CNTs) and pseudocapacitance (polymer). The trend in the electrode mass change in correlation with the capacitance suggest additional effects such as a solvent co-insertion into the polymer and the contribution of the charge associated with the redox activity of oxygen-containing functional groups on the carbon surface.

  10. A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus

    Science.gov (United States)

    Chen, Sz-Hau; Chuang, Yao-Chen; Lu, Yi-Chen; Lin, Hsiu-Chao; Yang, Yun-Liang; Lin, Chih-Sheng

    2009-05-01

    Dengue virus (DENV) is nowadays the most important arthropod-spread virus affecting humans existing in more than 100 countries worldwide. A rapid and sensitive detection method for the early diagnosis of infectious dengue virus urgently needs to be developed. In the present study, a circulating-flow quartz crystal microbalance (QCM) biosensing method combining oligonucleotide-functionalized gold nanoparticles (i.e. AuNP probes) used to detect DENV has been established. In the DNA-QCM method, two kinds of specific AuNP probes were linked by the target sequences onto the QCM chip to amplify the detection signal, i.e. oscillatory frequency change (ΔF) of the QCM sensor. The target sequences amplified from the DENV genome act as a bridge for the layer-by-layer AuNP probes' hybridization in the method. Besides being amplifiers of the detection signal, the specific AuNP probes used in the DNA-QCM method also play the role of verifiers to specifically recognize their target sequences in the detection. The effect of four AuNP sizes on the layer-by-layer hybridization has been evaluated and it is found that 13 nm AuNPs collocated with 13 nm AuNPs showed the best hybridization efficiency. According to the nanoparticle application, the DNA-QCM biosensing method was able to detect dengue viral RNA in virus-contaminated serum as plaque titers being 2 PFU ml-1 and a linear correlation (R2 = 0.987) of ΔF versus virus titration from 2 × 100 to 2 × 106 PFU ml-1 was found. The sensitivity and specificity of the present DNA-QCM method with nanoparticle technology showed it to be comparable to the fluorescent real-time PCR methods. Moreover, the method described herein was shown to not require expensive equipment, was label-free and highly sensitive.

  11. Development of a rubber elongation factor, surface-imprinted polymer-quartz crystal microbalance sensor, for quantitative determination of Hev b1 rubber latex allergens present in natural rubber latex products.

    Science.gov (United States)

    Sontimuang, Chonlatid; Suedee, Roongnapa; Canyuk, Bhutorn; Phadoongsombut, Narubodee; Dickert, Franz L

    2011-02-21

    Molecularly imprinted polymers (MIPs) for screening to detect rubber latex allergens (Hev b1) in natural rubber based products were designed as artificial recognition polymeric materials coated onto a quartz crystal microbalance (QCM). The polymers were prepared using a stamp imprinting procedure after mixing optimum amounts of methacrylic acid-vinylpyrrolidone-dihydroxyethylene bisacrylamide and Hev b1 latex allergen proteins, obtained from rubber gloves. QCM measurements showed that the resulting polymer layers after removal of the proteins used in their preparation could incorporate structures and features down to nanometer scale of protein templates into the imprinted polymer much better than a non-specific control polymer under controlled sensor conditions and an optimized polymerization process. This selective polymer but not the non-selective polymer clearly distinguished between the latex allergen Hev b1 and proteins such as lysozyme, ovalbumin and bovine serum albumin, with a selectivity factor of from 2 to 4, and the response of the rubber elongation factors by an astonishing factor of 12. The imprinted cavities recognized specific binding sites and could distinguish among related hevein latex allergenic proteins isolated from fresh natural rubber latex; Hev b1, Hev b2, and Hev b3 with a selectivity factor of from 4 to 6. The different QCM measurements obtained presumably reflected slightly different conformations and affinities to the MIP binding sites. The sensor layers selectively adsorbed Hev b1 within minutes in amounts ranging from 10 to 1500 μg L⁻¹ and with a detection limit of 1 μg L⁻¹. This work has demonstrated that this new sensor provides a fast and reliable response to natural rubber latex protein, even after being extracted from the matrix of rubber gloves.

  12. A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S-H; Chuang, Y-C; Lu, Y-C; Lin, H-C; Yang, Y-L; Lin, C-S [Department of Biological Science and Technology, National Chiao Tung University, Hsinchu 30068, Taiwan (China)], E-mail: lincs@mail.nctu.edu.tw

    2009-05-27

    Dengue virus (DENV) is nowadays the most important arthropod-spread virus affecting humans existing in more than 100 countries worldwide. A rapid and sensitive detection method for the early diagnosis of infectious dengue virus urgently needs to be developed. In the present study, a circulating-flow quartz crystal microbalance (QCM) biosensing method combining oligonucleotide-functionalized gold nanoparticles (i.e. AuNP probes) used to detect DENV has been established. In the DNA-QCM method, two kinds of specific AuNP probes were linked by the target sequences onto the QCM chip to amplify the detection signal, i.e. oscillatory frequency change ({delta}F) of the QCM sensor. The target sequences amplified from the DENV genome act as a bridge for the layer-by-layer AuNP probes' hybridization in the method. Besides being amplifiers of the detection signal, the specific AuNP probes used in the DNA-QCM method also play the role of verifiers to specifically recognize their target sequences in the detection. The effect of four AuNP sizes on the layer-by-layer hybridization has been evaluated and it is found that 13 nm AuNPs collocated with 13 nm AuNPs showed the best hybridization efficiency. According to the nanoparticle application, the DNA-QCM biosensing method was able to detect dengue viral RNA in virus-contaminated serum as plaque titers being 2 PFU ml{sup -1} and a linear correlation (R{sup 2} = 0.987) of {delta}F versus virus titration from 2 x 10{sup 0} to 2 x 10{sup 6} PFU ml{sup -1} was found. The sensitivity and specificity of the present DNA-QCM method with nanoparticle technology showed it to be comparable to the fluorescent real-time PCR methods. Moreover, the method described herein was shown to not require expensive equipment, was label-free and highly sensitive.

  13. Measuring phonons in protein crystals

    Science.gov (United States)

    Niessen, Katherine A.; Snell, Edward; Markelz, A. G.

    2013-03-01

    Using Terahertz near field microscopy we find orientation dependent narrow band absorption features for lysozyme crystals. Here we discuss identification of protein collective modes associated with the observed features. Using normal mode calculations we find good agreement with several of the measured features, suggesting that the modes arise from internal molecular motions and not crystal phonons. Such internal modes have been associated with protein function.

  14. A Novel Signal-Amplified Immunoassay for the Detection of C-Reactive Protein Using HRP-Doped Magnetic Nanoparticles as Labels with the Electrochemical Quartz Crystal Microbalance as a Detector

    Directory of Open Access Journals (Sweden)

    Ning Gan

    2013-01-01

    Full Text Available A novel horseradish peroxidase- (HPR- doped magnetic core-shell Fe3O4@SiO2@Au nanocomposites (Fe-Au MNPs were employed on immunoassay for the determination of C-reactive protein (CRP based on a electrochemical quartz crystal microbalance detector (EQCM. Firstly, the secondary CRP antibody and HRP were both immobilized on the Fe-Au MNPs (Fe-Au MNPs-anti-CRP2/HRP as a signal tag. Secondly, the above tag and the primary antibody (anti-CRP1 in the bottom of 96-well microtiter plate were employed to conjugate with a serial of CRP concentrations to produce a sandwich immunocomplex. Thirdly, the immunocomplex solution was subsequently exposed to 3,3′-diaminobenzidine (DAB in the presence of H2O2, resulting in an insoluble product. When the precipitation solution was dripped on EQCM, it can achieve a decrease of frequency of crystal (Δf. The amount of Δf was proportional to (CRP from 0.003 to 200 ng mL−1 with a low detection limit of 1 pg mL−1. Compared with the enzyme-linked immunosorbent assay (ELISA, the immunoassay shows greatly improved sensitivity due to the significant amount of HRP labeled on signal tag. It also has good specificity and low sample consumption, which is expected to be a benefit for the CRP screening in early diagnosis of cardiovascular disease.

  15. Nucleation-fibrillation dynamics of Aβ1-40 peptides on liquid-solid surface studied by total-internal-reflection fluorescence microscopy coupled with quartz-crystal microbalance biosensor

    Science.gov (United States)

    Hamada, Hiroki; Ogi, Hirotsugu; Noi, Kentaro; Yagi, Hisashi; Goto, Yuji; Hirao, Masahiko

    2015-07-01

    We have successfully developed the total-internal-reflection-fluorescence microscopy combined with a quartz-crystal microbalance (TIRFM-QCM) biosensor, and monitored the nucleation-fibrillation phenomenon of amyloid β1-40 peptide on the naked quartz surface. The cross-β-sheet structures were visualized with the TIRFM using the thioflavin-T (Th-T) label, and other unlabeled aggregates were detected through the frequency change of the 58-MHz wireless-electrodeless QCM throughout the aggregation reaction. The QCM response indicates significant adsorption of the peptides on the quartz surface at the early stage, which is followed by fibrillation. The non-cross-β-sheet oligomers are first formed, and nuclei appear in the oligomer region, from which fibrils originate and elongate. The two-color TIRFM observation was performed after the aggregation reaction with the Nile-red label as well as the ThT label for identifying nucleation from non-β-sheet regions. An aggregation model is proposed.

  16. pH- and Electro-Responsive Properties of Poly(acrylic acid) and Poly(acrylic acid)-block-poly(acrylic acid-grad-styrene) Brushes Studied by Quartz Crystal Microbalance with Dissipation Monitoring.

    Science.gov (United States)

    Borisova, O V; Billon, L; Richter, R P; Reimhult, E; Borisov, O V

    2015-07-14

    We report on the synthesis of novel pH- and electro-responsive polyelectrolyte brushes from a gold substrate by direct one-step nitroxide-mediated polymerization of acrylic acid (AA) or copolymerization of AA and styrene (S). In the latter case, amphiphilic brushes of block-gradient copolymers PAA-b-(PAA-grad-PS) comprising one PAA block and one block with the gradient sequence of AA and S were obtained. The block-gradient copolymers are initiated from the surface by the start of the PAA block. The brushes were characterized by XPS and ellipsometry. (1)H NMR confirmed the gradient sequence of the PAA-grad-PS copolymer block. The pH- and electro-responsive properties of the brushes were studied by quartz crystal microbalance with dissipation monitoring (QCM-D) in combination with electrochemistry. This method provides evidence of swelling of the PAA brushes proportional to the contour length of the chains at elevated pH, whereas the response functions of the block-gradient copolymers are more complex and point to intermolecular aggregation in the brush at low pH. Monitoring of the changes in resonance frequency and dissipation of the QCM-D also demonstrates that application of negative voltage to the substrate leads to swelling of the brush; application of a positive voltage provokes only a transient collapse of the brush in proportion to the applied voltage.

  17. In Situ Adsorption Studies at the Solid/Liquid Interface:Characterization of Biological Surfaces and Interfaces Using SumFrequency Generation Vibrational Spectroscopy, Atomic Force Microscopy,and Quartz Crystal Microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Diana Christine [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Sum frequency generation (SFG) vibrational spectroscopy, atomic force microscopy (AFM), and quartz crystal microbalance (QCM) have been used to study the molecular surface structure, surface topography and mechanical properties, and quantitative adsorbed amount of biological molecules at the solid-liquid interface. The molecular-level behavior of designed peptides adsorbed on hydrophobic polystyrene and hydrophilic silica substrates has been examined as a model of protein adsorption on polymeric biomaterial surfaces. Proteins are such large and complex molecules that it is difficult to identify the features in their structure that lead to adsorption and interaction with solid surfaces. Designed peptides which possess secondary structure provide simple model systems for understanding protein adsorption. Depending on the amino acid sequence of a peptide, different secondary structures (α-helix and β-sheet) can be induced at apolar (air/liquid or air/solid) interfaces. Having a well-defined secondary structure allows experiments to be carried out under controlled conditions, where it is possible to investigate the affects of peptide amino acid sequence and chain length, concentration, buffering effects, etc. on adsorbed peptide structure. The experiments presented in this dissertation demonstrate that SFG vibrational spectroscopy can be used to directly probe the interaction of adsorbing biomolecules with a surface or interface. The use of well designed model systems aided in isolation of the SFG signal of the adsorbing species, and showed that surface functional groups of the substrate are sensitive to surface adsorbates. The complementary techniques of AFM and QCM allowed for deconvolution of the effects of surface topography and coverage from the observed SFG spectra. Initial studies of biologically relevant surfaces are also presented: SFG spectroscopy was used to study the surface composition of common soil bacteria for use in bioremediation of nuclear waste.

  18. “固化水层”模型拓展石英晶体微天平的应用%Applications of Quartz Crystal Microbalance with Solidified Liquid Layer Model

    Institute of Scientific and Technical Information of China (English)

    顾莉娟; 汪杰; 马宏伟

    2013-01-01

    Quartz crystal microbalance (QCM) has many advantages in research,but the data interpretation has hindered its applications in many research fields,especially for application in liquid.Recently,we proposed'solidified liquid layer' (SLL) model to simplify the data analysis.In this article,some missing evidences are provided to demonstrate the SLL model.The thickness result from ellipsometry accords with the result from the SLL model.The SLL model predicts that 1 Hz signal respond to a 0.18-nm change of TSLL,which greatly improve the resolution of QCMs in liquid.These researches effectively improve our understanding in the nature of Au—S bond breakage and its breakage process.Our results show that the SLL model will improve the applications of QCM in many fields.%石英晶体微天平(QCM)在液态环境下的应用一直由于数据分析复杂而受到限制.最近,我们提出了“固化水层”模型(SLL)以简化QCM数据分析过程.本文进一步提供了SLL模型的有关数据.根据SLL模型,1 Hz QCM频率信号对应于0.18 nm SLL层厚度的变化,而大多数商业的QCM均可以达到该精度.因此,根据SLL模型设计的检测方案将具有很高的灵敏度.QCM作为生物传感器的应用也得以拓展,可以相信SLL模型将大大增强QCM的分析能力.

  19. Charge Transport Processes of Immobilized Heteropolyanions at Self-assembled Monolayer Modified Gold Electrode by Electrochemical Quartz Crystal Microbalance Measurement

    Institute of Scientific and Technical Information of China (English)

    BU Xin-yuan; JIAO Lian-sheng; HAN Dong-xue; YANG Gui-fu

    2009-01-01

    ions in a 1 mol/L H2SO4 solution and played a key role in the abnormal change of the resonant fequency. Such a change was attributed to different packing densities derived by means of differently immobilized methods.

  20. In situ investigation of dye adsorption on TiO2 films using a quartz crystal microbalance with a dissipation technique

    KAUST Repository

    Harms, Hauke A.

    2012-01-01

    Dye adsorption plays a crucial role in dye-sensitized solar cells. Herein, we demonstrate an in situ liquid-phase analytical technique to quantify in real time adsorption of dye and coadsorbates on flat and mesoporous TiO 2 films. For the first time, a molar ratio of co-adsorbed Y123 and chenodeoxycholic acid has been measured. © 2012 the Owner Societies.

  1. Quartz Crystal Microbalance with Dissipation Monitoring

    Science.gov (United States)

    2014-11-06

    immobilized onto the gold sensor in citric buffer (pH = 4), rinsed and washed subsequently in cycles of citric buffer (pH = 4) and PBS buffer (pH...dissipation (tougher) at acidic pH, with excellent reversibility up to five cycles . At pH = 7.4, a higher dissipation was observed in the triblock...CcE20Cc (Figure 2) was engineered with a long glutamic acid (Glu)-abundant E20 block (red, containing 40 mol % of Glu) in the middle and joined at

  2. Thermal conductivity measurements of laser crystals by infrared thermography. Application to Nd:doped crystals.

    Science.gov (United States)

    Didierjean, Julien; Herault, Emilie; Balembois, François; Georges, Patrick

    2008-06-09

    We present a thermal conductivity measurement method for laser crystals based on thermal mapping of the crystal face by an infrared camera. Those measurements are performed under end-pumping of the laser crystal and during laser operation. The calculation of the fraction of pump power converted into heat is therefore simplified, and it is possible to link easily the temperature in the crystal to the thermal conductivity. We demonstrate the efficiency of this measurement method with a Nd:YAG crystal, before using it to compare Nd:YVO(4) and Nd:GdVO(4) crystals.

  3. Polarization factor measurements of flat crystals using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Wohrer, K.; Touati, A.; Chetioui, A.; Rozet, J.P.; Chevallier, P.; Wang, J.X.; Bouisset, P.

    1989-01-01

    A method for measuring polarization factors of flat crystals, using a highly polarized beam source provided by synchrotron radiation, is presented. Application to the test of a graphite mosaic crystal, performed at the LURE-DCI facility in Orsay (France), is reported. Results concerning polarization factors at different energies are discussed in connection with measured crystal reflectivities.

  4. Thermal conductivity measurements of laser crystals by infrared thermography. Application to Nd:doped crystals

    OpenAIRE

    Didierjean, Julien; Hérault, Emilie; Balembois, François; Georges, Patrick

    2008-01-01

    International audience; We present a thermal conductivity measurement method for laser crystals based on thermal mapping of the crystal face by an infrared camera. Those measurements are performed under end-pumping of the laser crystal and during laser operation. The calculation of the fraction of pump power converted into heat is therefore simplified, and it is possible to link easily the temperature in the crystal to the thermal conductivity. We demonstrate the efficiency of this measuremen...

  5. Directs measurement of high temperature/high pressure solubility of methane and carbon dioxide in polyamide (PA-11) using a high-pressure microbalance

    DEFF Research Database (Denmark)

    von Solms, Nicolas; Rubin, A; Andersen, Simon Ivar

    2005-01-01

    Experiments to determine the Solubility of methane and carbon dioxide in PA-11 have been performed in the temperature range 50-90&DEG; C and the pressure ranges 50-150 bar for methane and 20-40 bar for carbon dioxide. In general, the results agree fairly well with previous experiments for similar...... to more uncertainty than the solubility measurements, the expected (Arrhenius) trends are observed. Agreement with other experimental data using different methods is also good....

  6. Measurements of Protein Crystal Face Growth Rates

    Science.gov (United States)

    Gorti, S.

    2014-01-01

    Protein crystal growth rates will be determined for several hyperthermophile proteins.; The growth rates will be assessed using available theoretical models, including kinetic roughening.; If/when kinetic roughening supersaturations are established, determinations of protein crystal quality over a range of supersaturations will also be assessed.; The results of our ground based effort may well address the existence of a correlation between fundamental growth mechanisms and protein crystal quality.

  7. Anticlastic curvature measurements on unribbed crystal optics for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Quintana, J.P.; Dolin, Y.; Georgopoulos, P. (DND-CAT Synchrotron Research Center, APS/ANL Sector 5, Building 400, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States)); Kushnir, V.I. (APS/XFD, Bldg. 362, 9700 South Cass Ave., Argonne, Illinois 60439 (United States))

    1995-02-01

    Various methods have been proposed for measuring the distortion in perfect crystals using double-crystal methods. The majority of these methods rely on making comparisons between double-crystal rocking curve measurements under the spatial extent of an extended x-ray beam. Unless the beam is large and parallel (such as at a synchrotron bending magnet), these methods are not easily scalable to large crystals (e.g., crystal focusing elements for synchrotron beamlines) due to the mechanical inaccuracies inherent in moving the various optical components. We present a method based on a scanning source which simplifies the problems in scaling double-crystal methods to large optics. In addition, results using this method are presented on a ribless sagittal focusing Si(111) crystal demonstrating that the anticlastic deviation can be made to be less than [plus minus]1 s of arc over a 1-cm-long section parallel to the sagittal axis.

  8. Searching for the Best Protein Crystals: Synchrotron Based Measurements of Protein Crystal Quality

    Science.gov (United States)

    Borgstahl, Gloria; Snell, Edward H.; Bellamy, Henry; Pangborn, Walter; Nelson, Chris; Arvai, Andy; Ohren, Jeff; Pokross, Matt

    1999-01-01

    We are developing X-ray diffraction methods to quantitatively evaluate the quality of protein crystals. The ultimate use for these crystal quality will be to optimize crystal growth and freezing conditions to obtain the best diffraction data. We have combined super fine-phi slicing with highly monochromatic, low divergence synchrotron radiation and the ADSC Quantum 4 CCD detector at the Stanford Synchrotron Radiation laboratory beamline 1.5 to accurately measure crystal mosaicity. Comparisons of microgravity versus earth-grown insulin crystals using these methods will be presented.

  9. Measurement & Minimization of Mount Induced Strain on Double Crystal Monochromator Crystals

    Science.gov (United States)

    Kelly, J.; Alcock, S. G.

    2013-03-01

    Opto-mechanical mounts can cause significant distortions to monochromator crystals and mirrors if not designed or implemented carefully. A slope measuring profiler, the Diamond-NOM [1], was used to measure the change in tangential slope as a function of crystal clamping configuration and load. A three point mount was found to exhibit the lowest surface distortion (Diamond Light Source.

  10. Systematic hardness measurements on some rare earth garnet crystals

    Indian Academy of Sciences (India)

    D B Sirdeshmukh; L Sirdeshmukh; K G Subhadra; K Kishan Rao; S Bal Laxman

    2001-10-01

    Microhardness measurements were undertaken on twelve rare earth garnet crystals. In yttrium aluminium garnet and gadolinium gallium garnet, there was no measurable difference in the hardness values of pure and nominally Nd-doped crystals. The hardness values were correlated with the lattice and elastic constants. An analysis of hardness data in terms of the interatomic binding indicated a high degree of covalency.

  11. Gyroscopic Inertial Micro-Balance Azimuth Locator (GIMBAL) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Research Support Instruments, Inc. (RSI) proposes the Gyroscopic Inertial Micro-Balance Azimuth Locator (GIMBAL) program to use an innovative encapsulated spinning...

  12. The C-Test: An Integrative Measure of Crystallized Intelligence

    Directory of Open Access Journals (Sweden)

    Purya Baghaei

    2015-05-01

    Full Text Available Crystallized intelligence is a pivotal broad ability factor in the major theories of intelligence including the Cattell-Horn-Carroll (CHC model, the three-stratum model, and the extended Gf-Gc (fluid intelligence-crystallized intelligence model and is usually measured by means of vocabulary tests and other verbal tasks. In this paper the C-Test, a text completion test originally proposed as a test of general proficiency in a foreign language, is introduced as an integrative measure of crystallized intelligence. Based on the existing evidence in the literature, it is argued that the construct underlying the C-Test closely matches the abilities underlying the language component of crystallized intelligence, as defined in the well-established theories of intelligence. It is also suggested that by carefully selecting texts from pertinent knowledge domains, the factual knowledge component of crystallized intelligence could also be measured by the C-Test.

  13. Unexpected results from direct measurement, with a torsion microbalance in a closed system, of calcification rates of the coral Agaricia agaricites (Scleractinia:Agariicidae and concomitant changes in seawater pH

    Directory of Open Access Journals (Sweden)

    Ian M. Sandeman

    2014-09-01

    Full Text Available Ocean acidification is impacting the calcification of corals, but the mechanisms of calcification are still unclear. To explore the relationship between calcification and pH, small pieces of coral were suspended from a torsion microbalance in gently stirred, temperature controlled, seawater in a closed chamber. Net calcification rate and pH were continuously monitored while light, temperature or pH could be manipulated. The coral pieces were from the edges of thin plates of Agaricia agaricites and were studied alive and freshly collected. Unexpectedly, when calcification was taking place (n=9, 0.082 mg.hr-1.cm-2, as determined by weight increase, the pH of the surrounding seawater medium changed little (n=10, -0.0047 pH units.hr-1.cm-2. When calcification was not taking place the decrease of seawater pH was an order of magnitude higher, -0.013 pH units.hr-1.cm-2. This is the opposite of what is expected when calcium carbonate (CaCO3 forms. Similarly, fresh skeleton initially showed no change of pH in the seawater medium although the rates of weight gain were high (upto 1.0 mg hr-1.cm-2. After 10 hours, as the rate of deposition decreased following a generalized Michaelis-Menten growth curve, the pH began to decrease dramatically indicating an increase of CO2 in the seawater. These unexpected results can be explained if unstable calcium bicarbonate (Ca(HCO³2 is formed in the organic matrix/carbonic anhydrase surface and slowly transforms later to CaCO3. Pieces of living coral monitored in the chamber for 30 hours gained weight during the day and loss it at night. The loss would be consistent with the transformation of Ca(HCO³2 to CaCO3 with the release of CO2. The mean calcification rate of live coral was greater (n=8, p=0.0027 in high light (120 μmol.s-1.m-2 at 0.098 mg.hr-1.cm-2, compared to 0.063 mg.hr-1.cm-2 in low light (12 μmol.s-1.m-2. However, at the same time the mean rate of pH change was -0.0076 under low light compared to -0

  14. The construction of the CMS electromagnetic calorimeter: automatic measurements of the physics parameters of PWO crystals

    CERN Multimedia

    2005-01-01

    Crystal properties (dimensions, optical transmission, light yield) are automatically measured. The pictures show different measurement stations of the automatic machine. Crystals are measured on trays containing five crystals each.

  15. Piezoresistance measurement on single crystal silicon nanowires

    Science.gov (United States)

    Toriyama, Toshiyuki; Funai, Daisuke; Sugiyama, Susumu

    2003-01-01

    A p-type single crystal silicon nanowire bridge and a four-terminal nanowire element were fabricated by electron-beam direct writing. The piezoresistance was investigated in order to demonstrate the usefulness of these sensing elements as mechanical sensors. The longitudinal piezoresistance coefficient πl[110] was found to be 38.7×10-11 Pa-1 at a surface impurity concentration of Ns=9×1019cm-3 for the nanowire bridge. The shear piezoresistance coefficient π44 was found to be 77.4×10-11 Pa-1 at Ns=9×1019 cm-3 for the four-terminal nanowire element. These values are 54.8% larger than the values obtained from p+ diffused piezoresistors, which are used in conventional mechanical sensors.

  16. Liquid Crystal Thermography Measurement Uncertainty Analysis and Its Application to Turbulent Heat Transfer Measurements

    Directory of Open Access Journals (Sweden)

    Yu Rao

    2012-01-01

    Full Text Available Liquid crystal thermography is an advanced nonintrusive measurement technique, which is capable of providing a high-accuracy continuous temperature field measurement, especially for a complex structured heat transfer surface. The first part of the paper presents a comprehensive introduction to the thermochromic liquid crystal material and the related liquid crystal thermography technique. Then, based on the aythors' experiences in using the liquid crystal thermography for the heat transfer measurement, the parameters affecting the measurement uncertainty of the liquid crystal thermography have been discussed in detail through an experimental study. The final part of the paper describes the applications of the steady and transient liquid crystal thermography technique in the study of the turbulent flow heat transfer related to the aeroengine turbine blade cooling.

  17. Nonlinear refractive index measurements of glasses and crystals

    Science.gov (United States)

    Adair, R.; Chase, L. L.; Payne, S. A.

    1987-12-01

    We have measured the nonlinear index for numerous glasses and crystals with the goal of determining the material properties that contribute to the magnitude and dispersion of n sub 2. We have found that a nearly-degenerate three-wave-mixing (TWM) process is the most useful method since it can provide both rapid and accurate n sub 2 measurements.

  18. Sidewall roughness measurement of photonic wires and photonic crystals

    DEFF Research Database (Denmark)

    Svalgaard, Mikael; Frandsen, Lars Hagedorn; Garnæs, Jørgen;

    2007-01-01

    The performance of nanophotonic building blocks such as photonic wires and photonic crystals are rapidly improving, with very low propagation loss and very high cavity Q-factors being reported. In order to facilitate further improvements in performance the ability to quantitatively measure...

  19. Measurement of the neutron electric dipole moment by crystal diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, V.V. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Jentschel, M. [Institut Laue-Langevin, Grenoble (France); Kuznetsov, I.A.; Lapin, E.G. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Lelievre-Berna, E.; Nesvizhevsky, V.; Petoukhov, A. [Institut Laue-Langevin, Grenoble (France); Semenikhin, S.Yu. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Soldner, T.; Tasset, F. [Institut Laue-Langevin, Grenoble (France); Voronin, V.V., E-mail: vvv@pnpi.spb.r [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Braginetz, Yu.P. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation)

    2009-12-11

    An experiment using a prototype setup to search for the neutron electric dipole moment by measuring spin rotation in a non-centrosymmetric crystal (quartz) was carried out to investigate statistical sensitivity and systematic effects of the method. It has been demonstrated that the concept of the method works. The preliminary result of the experiment is d{sub n}=(2.5+-6.5)x10{sup -24}ecm. The experiment showed that an accuracy of approx2.5x10{sup -26}ecm can be obtained in 100 days data taking, using available quartz crystals and neutron beams.

  20. Measurement of the neutron electric dipole moment by crystal diffraction

    CERN Document Server

    Fedorov, V V; Kuznetsov, I A; Lapin, E G; Lelievre-Berna, E; Nesvizhevsky, V; Petoukhov, A; Semenikhin, S Yu; Soldner, T; Tasset, F; Voronin, V V; Braginetz, Yu P

    2009-01-01

    An experiment using a prototype setup to search for the neutron electric dipole moment by measuring spin-rotation in a non-centrosymmetric crystal (quartz) was carried out to investigate statistical sensitivity and systematic effects of the method. It has been demonstrated that the concept of the method works. The preliminary result of the experiment is $d_{\\rm n}=(2.5\\pm 6.5)\\cdot 10^{-24}$ e$\\cdot $cm. The experiment showed that an accuracy of $\\sim 2.5\\cdot 10^{-26}$ e$\\cdot $cm can be obtained in 100 days data taking, using available quartz crystals and neutron beams.

  1. Neutron transmission measurements of poly and pyrolytic graphite crystals

    Science.gov (United States)

    Adib, M.; Abbas, Y.; Abdel-Kawy, A.; Ashry, A.; Kilany, M.; Kenawy, M. A.

    The total neutron cross-section measurements of polycrystalline graphite have been carried out in a neutron wavelength from 0.04 to 0.78 nm. This work also presents the neutron transmission measurements of pyrolytic graphite (PG) crystal in a neutron wavelength band from 0.03 to 0.50 nm, at different orientations of the PG crystal with regard to the beam direction. The measurements were performed using three time-of-flight (TOF) spectrometers installed in front of three of the ET-RR-1 reactor horizontal channels. The average value of the coherent scattering amplitude for polycrystalline graphite was calculated and found to be bcoh = (6.61 ± 0.07) fm. The behaviour of neutron transmission through the PG crystal, while oriented at different angles with regard to the beam direction, shows dips at neutron wavelengths corresponding to the reflections from (hkl) planes of hexagonal graphite structure. The positions of the observed dips are found to be in good agreement with the calculated ones. It was also found that a 40 mm thick PG crystal is quite enough to reduce the second-order contamination of the neutron beam from 2.81 to 0.04, assuming that the incident neutrons have a Maxwell distribution with neutron gas temperature 330 K.

  2. Adsorption calorimetry during metal vapor deposition on single crystal surfaces: Increased flux, reduced optical radiation, and real-time flux and reflectivity measurements

    Science.gov (United States)

    Sellers, Jason R. V.; James, Trevor E.; Hemmingson, Stephanie L.; Farmer, Jason A.; Campbell, Charles T.

    2013-12-01

    Thin films of metals and other materials are often grown by physical vapor deposition. To understand such processes, it is desirable to measure the adsorption energy of the deposited species as the film grows, especially when grown on single crystal substrates where the structure of the adsorbed species, evolving interface, and thin film are more homogeneous and well-defined in structure. Our group previously described in this journal an adsorption calorimeter capable of such measurements on single-crystal surfaces under the clean conditions of ultrahigh vacuum [J. T. Stuckless, N. A. Frei, and C. T. Campbell, Rev. Sci. Instrum. 69, 2427 (1998)]. Here we describe several improvements to that original design that allow for heat measurements with ˜18-fold smaller standard deviation, greater absolute accuracy in energy calibration, and, most importantly, measurements of the adsorption of lower vapor-pressure materials which would have previously been impossible. These improvements are accomplished by: (1) using an electron beam evaporator instead of a Knudsen cell to generate the metal vapor at the source of the pulsed atomic beam, (2) changing the atomic beam design to decrease the relative amount of optical radiation that accompanies evaporation, (3) adding an off-axis quartz crystal microbalance for real-time measurement of the flux of the atomic beam during calorimetry experiments, and (4) adding capabilities for in situ relative diffuse optical reflectivity determinations (necessary for heat signal calibration). These improvements are not limited to adsorption calorimetry during metal deposition, but also could be applied to better study film growth of other elements and even molecular adsorbates.

  3. Determination of struvite crystallization mechanisms in urine using turbidity measurement.

    Science.gov (United States)

    Triger, Aurélien; Pic, Jean-Stéphane; Cabassud, Corinne

    2012-11-15

    Sanitation improvement in developing countries could be achieved through wastewater treatment processes. Nowadays alternative concepts such as urine separate collection are being developed. These processes would be an efficient way to reduce pollution of wastewater while recovering nutrients, especially phosphorus, which are lost in current wastewater treatment methods. The precipitation of struvite (MgNH(4)PO(4)∙6H(2)O) from urine is an efficient process yielding more than 98% phosphorus recovery with very high reaction rates. The work presented here aims to determine the kinetics and mechanisms of struvite precipitation in order to supply data for the design of efficient urine treatment processes. A methodology coupling the resolution of the population balance equation to turbidity measurement was developed, and batch experiments with synthetic and real urine were performed. The main mechanisms of struvite crystallization were identified as crystal growth and nucleation. A satisfactory approximation of the volumetric crystal size distribution was obtained. The study has shown the low influence on the crystallization process of natural organic matter contained in real urine. It has also highlighted the impact of operational parameters. Mixing conditions can create segregation and attrition which influence the nucleation rate, resulting in a change in crystals number, size, and thus final crystal size distribution (CSD). Moreover urine storage conditions can impact urea hydrolysis and lead to spontaneous struvite precipitation in the stock solution also influencing the final CSD. A few limits of the applied methodology and of the proposed modelling, due to these phenomena and to the turbidity measurement, are also discussed.

  4. Quartz Crystal Microbalance Studies of Electrochemical Growth of Conducting Polymers

    Science.gov (United States)

    1989-06-15

    National Meeting of the Electrochemical Society , Hollywood, Florida, 1989 Corrosion Research Center Department of Chemical Engineering and Materials Science...176th Meeting of the Electrochemical Society , Extended Abstracts, October 1989 17COSATI CODES 18 SUBJECT TERMS (Continue an reverse it necesi4iy anid

  5. Calorimetric Measurements at Low Temperatures in Toluene Glass and Crystal

    Science.gov (United States)

    Alvarez-Ney, C.; Labarga, J.; Moratalla, M.; Castilla, J. M.; Ramos, M. A.

    2017-04-01

    The specific heat of toluene in glass and crystal states has been measured both at low temperatures down to 1.8 K (using the thermal relaxation method) and in a wide temperature range up to the liquid state (using a quasiadiabatic continuous method). Our measurements therefore extend earlier published data to much lower temperatures, thereby allowing to explore the low-temperature "glassy anomalies" in the case of toluene. Surprisingly, no indication of the existence of tunneling states is found, at least within the temperature range studied. At moderate temperatures, our data either for the glass or for the crystal show good agreement with those found in the literature. Also, we have been able to prepare bulk samples of toluene glass by only doping with 2% mol ethanol instead of with higher impurity doses used by other authors.

  6. The Herbertsmithite Hamiltonian: {mu}SR measurements on single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ofer, Oren [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T2A3 (Canada); Keren, Amit [Department of Physics, Technion, Haifa 32000 (Israel); Brewer, Jess H [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T1Z1 (Canada); Han, Tianheng H; Lee, Young S, E-mail: oren@triumf.ca [Department of Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2011-04-27

    We present transverse field muon spin rotation/relaxation measurements on single crystals of the spin-1/2 kagome antiferromagnet Herbertsmithite. We find that the spins are more easily polarized when the field is perpendicular to the kagome plane. We demonstrate that the difference in magnetization between the different directions cannot be accounted for by Dzyaloshinskii-Moriya-type interactions alone and that anisotropic axial interaction is present.

  7. Comparison of High Temperature Crystal Lattice and Bulk Thermal Expansion Measurements of LGT Single Crystal

    Energy Technology Data Exchange (ETDEWEB)

    Beaucage, Timothy R [University of Maine; Beenfeldt, Eric P [University of Maine; Speakman, Scott A [ORNL; Porter, Wallace D [ORNL; Payzant, E Andrew [ORNL; Pereira da Cunha, Mauricio [University of Maine

    2006-01-01

    Among the langasite family of crystals (LGX), the three most popular materials are langasite (LGS, La3Ga5SiO14), langatate (LGT, La3Ga5.5Ta0.5O14) and langanite (LGN, La3Ga5.5Nb0.5O14). The LGX crystals have received significant attention for acoustic wave (AW) device applications due to several properties, which include: (1) piezoelectric constants about two and a half times those of quartz, thus allowing the design of larger bandwidth filters; (2) existence of temperature compensated orientations; (3) high density, with potential for reduced vibration and acceleration sensitivity; and (4) possibility of operation at high temperatures, since the LGX crystals do not present phase changes up to their melting point above 1400degC. The LGX crystals' capability to operate at elevated temperatures calls for an investigation on the growth quality and the consistency of these materials' properties at high temperature. One of the fundamental crystal properties is the thermal expansion coefficients in the entire temperature range where the material is operational. This work focuses on the measurement of the LGT thermal expansion coefficients from room temperature (25degC) to 1200degC. Two methods of extracting the thermal expansion coefficients have been used and compared: (a) dual push-rod dilatometry, which provides the bulk expansion; and (b) x-ray powder diffraction, which provides the lattice expansion. Both methods were performed over the entire temperature range and considered multiple samples taken from <001> Czochralski grown LGT material. The thermal coefficients of expansion were extracted by approximating each expansion data set to a third order polynomial fit over three temperature ranges reported in this work: 25degC to 400degC, 400degC to 900degC, 900degC to 1200degC. An accuracy of fit better than 35ppm for the bulk expansion and better than 10ppm for the lattice expansion have been obtained with the aforementioned polynomial fitting. The

  8. Measurement of probability distributions for internal stresses in dislocated crystals

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, Angus J.; Tarleton, Edmund; Vilalta-Clemente, Arantxa; Collins, David M. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Jiang, Jun; Britton, T. Benjamin [Department of Materials, Imperial College London, Royal School of Mines, Exhibition Road, London SW7 2AZ (United Kingdom)

    2014-11-03

    Here, we analyse residual stress distributions obtained from various crystal systems using high resolution electron backscatter diffraction (EBSD) measurements. Histograms showing stress probability distributions exhibit tails extending to very high stress levels. We demonstrate that these extreme stress values are consistent with the functional form that should be expected for dislocated crystals. Analysis initially developed by Groma and co-workers for X-ray line profile analysis and based on the so-called “restricted second moment of the probability distribution” can be used to estimate the total dislocation density. The generality of the results are illustrated by application to three quite different systems, namely, face centred cubic Cu deformed in uniaxial tension, a body centred cubic steel deformed to larger strain by cold rolling, and hexagonal InAlN layers grown on misfitting sapphire and silicon carbide substrates.

  9. Microball lens integrated fiber probe for optical frequency domain imaging

    Institute of Scientific and Technical Information of China (English)

    Jae-Ho Han; J.U.Kang

    2011-01-01

    An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the microball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired cross-sectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.%@@ An integrated microball lens fiber catheter probe is demonstrated,which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography(FDOCT).Simulation results are shown to gain the effect of the distance between the microball lens and the bare fiber to the focusing plane and beam width.The freedom of modifying the working distance and lateral resolution is shown.This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length.The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.

  10. Quartz Crystal Microbalance and Atomic Force Microscopy for Study of Carbohydrate-sensitive Multilayers Composed of Pheylboronic Acid Polymers%石英晶体微天平和原子力显微镜识别糖类化合物的苯硼酸接枝聚合物多层薄膜

    Institute of Scientific and Technical Information of China (English)

    袁文静; 钟彤; 闫晶; 薛中原; 齐伟; 王桦

    2015-01-01

    硼酸受体识别体系近年来被广泛用于糖的分子识别研究,硼酸在一定酸度条件下,可特异性结合含顺式邻位多羟基的物质(如二醇、糖等)。本实验利用EDC/NHS化学交联,3-氨基苯硼酸( APBA)与聚丙烯酸( PAA)反应,制得苯硼酸接枝的聚合物PAA-PBA,进而将此聚合物进行层层组装,获得苯硼酸功能化薄膜。利用石英晶体微天平( QCM)和原子力显微镜( AFM)分别从宏观和微观的角度监测分析了此薄膜表面对糖类化合物的识别性质。结果表明此类薄膜对一定浓度(>50μg/mL)的糖类化合物均能表现出明显识别,其中,对果糖识别最为明显。此体系抗干扰性好,可重复使用,长期保存后仍能较好保持性能。微观表面形貌观察发现糖类化合物在薄膜表面识别均匀,识别后薄膜表面粗糙度发生明显变化。本研究成果可望用于开发高选择性、高灵敏度的糖识别体系。%Boronic acids and their derivatives have been widely used in carbohydrate-sensitive materials because they can selectively bind 1,2-and 1,3-diol compounds, including sugars, to form cyclic boronate esters. In this work, pheylboronic acid ( PBA) moieties were grafted onto the backbone of poly( acrylic acid) ( PAA) through the condensation reaction between aminopheyl-boronic acid and carboxylic acid group of PAA in the presence of EDC/NHS, designed as PAA-PBA. Then the resulting PAA-PBA were assembled with poly ( ethyleneimine) ( PEI) to form PAA-PBA multilayer films. The sensing performance of the PEI/PAA-PBA film to carbohydrate (> 50 μg/mL ) , including glucose, fructose, mannose and galactose, has been investigated by combination of the complementary techniques of quartz crystal microbalance ( QCM ) and atomic force microscopy ( AFM) . It was demonstrated that the multilayer showed higher sensitivity to fructose than glucose, mannose and galactose. The interferences of ascorbic acid, uric acid and dopamine to the

  11. 40 CFR 92.110 - Weighing chamber and micro-balance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Weighing chamber and micro-balance. 92... Weighing chamber and micro-balance. (a) Ambient conditions—(1) Temperature. The temperature of the chamber.... (b) Weighing balance specifications. The microbalance used to determine the weights of all...

  12. X-Ray Line Measurements with High Efficiency Bragg Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Pak, A; Gregori, G; Knight, J; Campbell, K; Landen, O; Glenzer, S

    2004-04-01

    We have studied the focusing properties of two highly oriented pyrolitic graphite (HOPG) spectrometers, which differ in the degree of the mosaic spread: ZYA with a low mosaic spread ({gamma}=0.4 degrees) and ZYH with a large mosaic spread ({gamma}=3.5 degrees). In order to assess the crystal performance for a variety of different experiments, various K{alpha} and K{beta} x-ray lines have been produced using a high-intensity ({approx}>10{sup 17} W/cm{sup 2}) short-pulse ({approx} 100 fs) laser beam focused onto Ti, V, Zn, and Cu foils. The measured spectral resolution of the HOPG crystals in both first and second order diffraction has been compared with theoretical predictions. Using known values for the peak reflectivity of HOPG crystals, we have also computed K{alpha} x-ray conversion efficiencies of Ti, V, Zn, and Cu. These results are important to estimate the optimal conditions under which different types of HOPG monochromators can be used for the detection of weak x-ray signals as the one encountered in x-ray Thomson/Compton scattering experiments.

  13. Simulation and measurement of slow light in photonic crystal waveguides

    DEFF Research Database (Denmark)

    Lavrinenko, Andrei; Jacobsen, Rune Shim; Fage-Pedersen, Jacob

    Planar photonic crystals offer a fascinating means of manipulation of light in integrated,optical circuits. Such waveguides can be realized, as in the present investigations, byfabricating arrays of holes with sub-micrometer distance in the top layer of a silicon-oninsulatorwafer. The waveguides...... can be tailored such that the propagating mode achievesextreme dispersion as well as a low group velocity, allowing for realization of ultracompact, functional devices. Here, we present numerical modeling and measurements ofthe time-of-flight propagation of optical pulses. Near the cut...

  14. Simulation and measurement of slow light in photonic crystal waveguides

    DEFF Research Database (Denmark)

    Lavrinenko, Andrei; Jacobsen, Rune Shim; Fage-Pedersen, Jacob;

    Planar photonic crystals offer a fascinating means of manipulation of light in integrated,optical circuits. Such waveguides can be realized, as in the present investigations, byfabricating arrays of holes with sub-micrometer distance in the top layer of a silicon-oninsulatorwafer. The waveguides...... can be tailored such that the propagating mode achievesextreme dispersion as well as a low group velocity, allowing for realization of ultracompact, functional devices. Here, we present numerical modeling and measurements ofthe time-of-flight propagation of optical pulses. Near the cut...

  15. Photothermal method for absorption measurements in anisotropic crystals

    Science.gov (United States)

    Stubenvoll, M.; Schäfer, B.; Mann, K.; Novak, O.

    2016-02-01

    A measurement system for quantitative determination of both surface and bulk contributions to the photo-thermal absorption has been extended to anisotropic optical media. It bases upon a highly sensitive Hartmann-Shack wavefront sensor, accomplishing precise on-line monitoring of wavefront deformations of a collimated test beam transmitted perpendicularly through the laser-irradiated side of a cuboid sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test beam is distorted. Sign and magnitude depend on index change and expansion. By comparison with thermal theory, a calibration of the measurement is possible, yielding a quantitative absolute measure of bulk and surface absorption losses from the transient wavefront distortion. Results for KTP and BBO single crystals are presented.

  16. Drinking-Straw Microbalance and Seesaw: Stability and Instability

    Science.gov (United States)

    Chapman, Peter; Glasser, Leslie

    2015-01-01

    The mechanics of a beam balance are little appreciated and seldom understood. We here consider the conditions that result in a stable balance, with center of gravity below the fulcrum (pivot point), while an unstable balance results when the center of gravity is above the fulcrum. The highly sensitive drinking-straw microbalance, which uses a…

  17. Simultaneous NO and NO(2) DIAL measurement using BBO crystals.

    Science.gov (United States)

    Kölsch, H J; Rairoux, P; Wolf, J P; Wöste, L

    1989-06-01

    We report a new differential absorption lidar technique for measuring simultaneously the concentrations of NO and NO(2) in the atmosphere. The technique is based on the correlation of the 450-nm absorption band of NO(2) and 227-nm absorption band of NO by frequency doubling. This performance has been allowed by the advent of a new and highly efficient frequency doubling crystal: the beta-BaB(2)O(4). A test experiment on a NO/NO(2) emitter has been performed, demonstrating the efficiency of the technique. The detection limit is estimated to be ~1 ppm .m for NO(2) and 100 ppb.m for NO. The range of measurement is limited to 1 km, due to the strong UV Rayleigh scattering and O(2) absorption.

  18. Measurement of gas viscosity using photonic crystal fiber

    Science.gov (United States)

    Gao, R.-K.; Sheehe, S. L.; Kurtz, J.; O'Byrne, S.

    2016-11-01

    A new measurement technique for gas viscosity coefficient is designed and demonstrated using the technique of tunable diode laser absorption spectroscopy (TDLAS). Gas flow is driven by a pressure gradient between two gas cells, through a photonic crystal fiber (PCF) surrounded by a furnace for temperature adjustment. PCF with 20-micron diameter affords physical space for gas-light interaction and provides a basis for gas viscosity measurement by determining the time for flow to exit a capillary tube under the influence of a pressure gradient. Infrared radiation from a diode laser is coupled into the fiber to be guided through the gas, and the light attenuation due to absorption from the molecular absorbing species is measured by a photo detector placed at the exit of the fiber. A numerical model from Sharipov and Graur describing local number density distribution in a unsteady state is applied for the determination of gas viscosity, based on the number density of gas measured by the absorption of the laser light, using the Beer-Lambert law. The measurement system is confirmed by measuring the viscosity of CO2 as a reference gas.

  19. Rheo-NMR Measurements of Cocoa Butter Crystallized Under

    Energy Technology Data Exchange (ETDEWEB)

    Mudge, E.; Mazzanti, G

    2009-01-01

    Modifications of a benchtop NMR instrument were made to apply temperature control to a shearing NMR cell. This has enabled the determination in situ of the solid fat content (SFC) of cocoa butter under shearing conditions. The cocoa butter was cooled at 3 C/min to three final temperatures of 17.5, 20.0, and 22.5 C with applied shear rates between 45 and 720 s-1. Polymorphic transitions of the cocoa butter were determined using synchrotron X-ray diffraction with an identical shearing system constructed of Lexan. Sheared samples were shown to have accelerated phase transitions compared to static experiments. In experiments where form V was confirmed to be the dominant polymorph, the final SFC averaged around 50%. However, when other polymorphic forms were formed, a lower SFC was measured because the final temperature was within the melting range of that polymorph and only partial crystallization happened. A shear rate of 720 s-1 delayed phase transitions, likely due to viscous heating of the sample. Pulsed NMR is an invaluable tool for determining the crystalline fraction in hydrogen containing materials, yet its use for fundamental and industrial research on fat or alkanes crystallization under shear has only recently been developed.

  20. Rotation method for the measurement of thickness of Z-cut uniaxial crystals

    Science.gov (United States)

    Paranin, V. D.

    2015-12-01

    An original polarization method for the measurement of thickness of Z-cut uniaxial crystals employs the transmittance measurement of the polarizer-crystal-analyzer system at different rotation angles of the crystal. The mathematical analysis of the method is based on the optics of uniaxial crystals and Jones matrices. A measurement error of no greater than ±0.6 μm is estimated using the formula of a vector sum. Z-cut crystals of congruent lithium niobate with rated thicknesses of 514 and 554 μm are used to experimentally test the method and propose practical recommendations for applications.

  1. An Eletrochemical Quatrz Crystal Microbalance Study on Electrochemical Behavior of As(Ⅲ)at Au/Au and Pt/Au Electrodes%电镀铂/金的金电极上As(Ⅲ)电化学行为的电化学石英晶体微天平研究

    Institute of Scientific and Technical Information of China (English)

    黄素清; 黄钊; 谷铁安; 谢青季; 姚守拙

    2011-01-01

    Electrochemical behavior of As(Ⅲ)at Au/Au and Pt/Au electrodes was investigated with an electrochemical quartz crystal microbalance (EQCM) in Britton-Robinson ( B-R, pH = 1. 8 - 11. 2)buffer solutions and in 0. 1 or 0. 5 mol/L aqueous H2SO4. Through real-time process monitoring of the EQCM parameters (frequency etc. ) and enhancement of the electrode-response signals by pre-electrodeposition of As (0) , the electrodeposition of As (0) , the electrod-esurface-adsorption characteristics of As(Ⅲ) and As(Ⅴ) , and the pH-dependence of the electrochemistry of As species were investigated. The following main conclusions are reached: (1) electrodeposition of As(0) can occur on both electrodes, but electrodeposition of As(0) on Pt/Au is more significant, and the electrooxidation of As(0) electrodeposited on Pt/Au at sufficient quantity can exhibit two current peaks for oxidation of outer-layer As(0) followed by inner-layer As(0); (2) As(Ⅲ) can strongly adsorb on Pt/Au but its oxidation product as As(Ⅴ) can desorb from the electrode surface , and the adsorption of both As(Ⅲ) and As(Ⅴ) is very weak on Au/Au; (3) the electrooxidation current of As(Ⅲ) on Pt/Au tends to be the maximum in pH = 1. 8 B-R buffer solution and in 0.1 mol/L aqueous H2SO4. Based on the pre-adsorption of As(Ⅲ) on Pt/Au and its catalyzed electrooxidation stripping, we proposed a new linear sweep voltammetric electroanalysis method for the determination of As (Ⅲ) , by which the detection sensitivity for As(Ⅲ) can be 40-fold enhanced over the pre-adsorption-free case%采用电化学石英晶体微天平(EQCM)技术研究了Britton-Robinson(B-R,pH=1.8~11.2)缓冲溶液和H2SO4介质中电镀铂淦的金电极上As(Ⅲ)的循环伏安行为.通过实时监测EQCM频率等参数的变化过程并利用预电沉积As(O)放大电极响应信号,考察了两电极上As.(O)的电沉积、AsⅢ皿和AsⅤ助组分的吸附特性以及As组分电化学行为的pH依赖性.主要结论如

  2. Viscosity measurements of crystallizing andesite from Tungurahua volcano (Ecuador)

    Science.gov (United States)

    Cimarelli, Corrado; deBiasi, Lea; Hanson, Jonathan B.; Lavallée, Yan; Arzilli, Fabio; Dingwell, Donald B.

    2015-01-01

    Abstract Viscosity has been determined during isothermal crystallization of an andesite from Tungurahua volcano (Ecuador). Viscosity was continuously recorded using the concentric cylinder method and employing a Pt‐sheathed alumina spindle at 1 bar and from 1400°C to subliquidus temperatures to track rheological changes during crystallization. The disposable spindle was not extracted from the sample but rather left in the sample during quenching thus preserving an undisturbed textural configuration of the crystals. The inspection of products quenched during the crystallization process reveals evidence for heterogeneous crystal nucleation at the spindle and near the crucible wall, as well as crystal alignment in the flow field. At the end of the crystallization, defined when viscosity is constant, plagioclase is homogeneously distributed throughout the crucible (with the single exception of experiment performed at the lowest temperature). In this experiments, the crystallization kinetics appear to be strongly affected by the stirring conditions of the viscosity determinations. A TTT (Time‐Temperature‐Transformation) diagram illustrating the crystallization “nose” for this andesite under stirring conditions and at ambient pressure has been constructed. We further note that at a given crystal content and distribution, the high aspect ratio of the acicular plagioclase yields a shear‐thinning rheology at crystal contents as low as 13 vol %, and that the relative viscosity is higher than predicted from existing viscosity models. These viscosity experiments hold the potential for delivering insights into the relative influences of the cooling path, undercooling, and deformation on crystallization kinetics and resultant crystal morphologies, as well as their impact on magmatic viscosity. PMID:27656114

  3. Viscosity measurements of crystallizing andesite from Tungurahua volcano (Ecuador).

    Science.gov (United States)

    Chevrel, Magdalena Oryaëlle; Cimarelli, Corrado; deBiasi, Lea; Hanson, Jonathan B; Lavallée, Yan; Arzilli, Fabio; Dingwell, Donald B

    2015-03-01

    Viscosity has been determined during isothermal crystallization of an andesite from Tungurahua volcano (Ecuador). Viscosity was continuously recorded using the concentric cylinder method and employing a Pt-sheathed alumina spindle at 1 bar and from 1400°C to subliquidus temperatures to track rheological changes during crystallization. The disposable spindle was not extracted from the sample but rather left in the sample during quenching thus preserving an undisturbed textural configuration of the crystals. The inspection of products quenched during the crystallization process reveals evidence for heterogeneous crystal nucleation at the spindle and near the crucible wall, as well as crystal alignment in the flow field. At the end of the crystallization, defined when viscosity is constant, plagioclase is homogeneously distributed throughout the crucible (with the single exception of experiment performed at the lowest temperature). In this experiments, the crystallization kinetics appear to be strongly affected by the stirring conditions of the viscosity determinations. A TTT (Time-Temperature-Transformation) diagram illustrating the crystallization "nose" for this andesite under stirring conditions and at ambient pressure has been constructed. We further note that at a given crystal content and distribution, the high aspect ratio of the acicular plagioclase yields a shear-thinning rheology at crystal contents as low as 13 vol %, and that the relative viscosity is higher than predicted from existing viscosity models. These viscosity experiments hold the potential for delivering insights into the relative influences of the cooling path, undercooling, and deformation on crystallization kinetics and resultant crystal morphologies, as well as their impact on magmatic viscosity.

  4. The microball and Gammasphere: Research highlights and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, M.; Sarantites, D.G.; LaFosse, D.R.; Lerma, F. [Washington Univ., Saint Louis, MO (United States)

    1996-12-31

    The Microball, a compact, 4{pi} charged-particle detector array, has been used in conjunction with Gammasphere for numerous physics experiments, and more are planned in the near future. A summary of this research program is presented, and the device and its capabilities are described. An example of its use in the study of the population and entry state excitation energy distributions of normal and superdeformed bands in {sup 82}Sr is presented.

  5. Rapid X-ray crystal structure analysis in few second measurements using microstrip gas chamber

    CERN Document Server

    Ochi, A; Tanimori, T; Ohashi, Y; Toyokawa, H; Nishi, Y; Nishi, Y; Nagayoshi, T; Koishi, S

    2001-01-01

    X-ray crystal structure analysis using microstrip gas chamber was successfully carried out in a measurement time within a few seconds. The continuous rotation photograph method, in which most of the diffraction peaks can be obtained within one continuous rotation of the sample crystal (without stopping or oscillation), was applied for this measurement. As an example, the structure of a single crystal of ammonium bitartrate (r=1 mm, spherical) was measured. Diffraction spots from the sample, which were sufficient to obtain crystal structure, were successfully obtained by taking only 2 s measurements with a commercially available laboratory X-ray source.

  6. Ammonia sorption by Dawson acid studied by IR spectroscopy and microbalance

    Science.gov (United States)

    Micek-Ilnicka, A.; Gil, B.; Lalik, E.

    2005-04-01

    Using in-situ microbalance and infrared spectroscopy techniques the double ammonia proton complexation was traced. The results confirm the formation of N 2H 7+ dimer in solid Dawson acid H 6P 2W 18O 62, previously reported only for N 2H 7I and for (N 2H 7) 4SiW 12O 40. The formation of such dimers was evidenced by the microbalance results, the molar ratio of ammonia to proton was measured as 2:1 at 10.7 kPa and 298 K. The formation of NH 4+ monomer (band at 1410 cm -1) and N 2H 7+ dimer (1460 cm -1) was revealed by IR spectroscopy. Enthalpy of ammonia sorption on Dawson structure was calculated to be -127.9 kJ mol -1, indicating the lower acid strength of Dawson-type compared to that of the Keggin-type heteropolyacids, like H 4SiW 12O 40.

  7. Measuring the X-ray Resolving Power of Bent Potassium Acid Phthalate Diffraction Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, M. J. [NSTec; Wu, M. [SNL; Jacoby, K. D. [NSTec; Loisel, G. P. [SNL

    2014-11-01

    This report presents the results from measuring the X-ray resolving power of a curved potassium acid phthalate (KAP(001)) spectrometer crystal using two independent methods. It is part of a continuing effort to measure the fundamental diffraction properties of bent crystals that are used to study various characteristics of high temperature plasmas. Bent crystals like KAP(001) do not usually have the same diffraction properties as corresponding flat crystals. Models that do exist to calculate the effect of bending the crystal on the diffraction properties have simplifying assumptions and their accuracy limits have not been adequately determined. The type of crystals that we measured is being used in a spectrometer on the Z machine at Sandia National Laboratories (SNL) in Albuquerque, NM. The first technique for measuring the crystal resolving power measures the X-ray spectral line width of the characteristic lines from several metal anodes. The second method uses a diode X-ray source and a dual goniometer arrangement to measure the reflectivity curve of the KAP(001) crystal. The width of that curve is inversely proportional to the crystal resolving power. The measurement results are analyzed and discussed.

  8. Fabrication and measurements on coupled photonic crystal cavities

    DEFF Research Database (Denmark)

    Schubert, Martin; Nielsen, Henri Thyrrestrup; Frandsen, Lars Hagedorn;

    Quasi-three dimensional photonic crystals can be realized by fabricating thin membranes of high index material hanging in air patterned with sub-micron holes to create a photonic band gap for optical confinement in plane and total internal reflection for out of plane confinement. Introducing...... defects into the photonic crystal gives rise to defect states in the form of small confined modes. By embedding an active gain medium like quantum dots into the membrane makes it possible to realize lasers with ultra-small mode volumes and low thresholds. Unfortunately single cavity photonic crystal...

  9. A research of weak absorption measurements in crystal based on photothermal interferometry

    Science.gov (United States)

    Chen, Bing; Liu, Zongkai; Wang, Shiwu

    2013-07-01

    It is important for testing the process of crystal growing and crystal quality. This paper built a mathematical model based on principle of photothermal common-path interferometry, the index change induced in the crystal by the heating pump beam and the phase distortion of probe beam in the heated area are presented then obtain the intensity distribution of the interference in the near filed. Optical geometry of focusing pump beam and intersecting pump and probe beams at waist position of the pump beam is used. This optical instruction can be adjusted easily and stabilized. Now CRYSTECH have the largest NLO crystals product line in the world, especially KTP crystals. With absorption measurements in nonlinear laser crystal KTP as an example to investigate the experimental parameters affecting the photothermal interference signal and high measuring precision. The analysis of experimental data showed this kind of instruction can reach the measurement accuracy of 0.1ppm.

  10. Quartz Microbalance Study of 400-angstrom Thick Films near the lambda Point

    Science.gov (United States)

    Chan, Moses H. W.

    2003-01-01

    In a recent measurement we observed the thinning of an adsorbed helium film induced by the confinement of critical fluctuations a few millikelvin below the lambda point. A capacitor set-up was used to measure this Casimir effect. In this poster we will present our measurement of an adsorbed helium film of 400 angstroms near the lambda point with a quartz microbalance. For films this thick, we must take into account the non-linear dynamics of the shear waves in the fluid. In spite of the added complications, we were able to confirm the thinning of the film due to the Casimir effect and the onset of the superfluid transition. In addition, we observe a sharp anomaly at the bulk lambda point, most likely related to critical dissipation of the first sound. This work is carried out in collaboration with Rafael Garcia, Stephen Jordon and John Lazzaretti. This work is funded by NASA's Office of Biological and Physical Research under grant.

  11. In situ measurement and dynamic control of the evaporation rate in vapor diffusion crystallization of proteins

    Science.gov (United States)

    Shu, Zhan-Yong; Gong, Hai-Yun; Bi, Ru-Chang

    1998-08-01

    A special device with a weight-sensitive facility was designed for monitoring and controlling the water evaporation in vapor diffusion protein crystallization. The device made it possible to measure the weight of the drop in real time while the crystallization experiment was going on normally. The precise water equilibration curves under different crystallization conditions could be obtained automatically. By monitoring and controlling the evaporation rate, the crystallization of hen egg-white lysozyme and trichosanthin, a plant protein from Chinese herb, was optimized by regulating the reservoir solution dynamically. The experimental results of these two proteins indicate both the feasibility of the device and the usefulness of dynamic control technique. Compared with traditional crystallization experiments, dynamically controlled crystallization can reduce the number of nuclei, increase the crystal size and save experimental time effectively.

  12. Crystal growth of pure and impurity-doped lead chloride single crystals from the melt

    NARCIS (Netherlands)

    Willemsen, B.

    An account is given of the purification and the crystal growing of lead chloride. Difficulties observed are blackening of the material and the formation of oxides. It is evident that oxygen should be avoided. The influence of water vapour is studied with mass spectroscopy, crystal microbalance

  13. Crystal growth of pure and impurity-doped lead chloride single crystals from the melt

    NARCIS (Netherlands)

    Willemsen, B.

    1971-01-01

    An account is given of the purification and the crystal growing of lead chloride. Difficulties observed are blackening of the material and the formation of oxides. It is evident that oxygen should be avoided. The influence of water vapour is studied with mass spectroscopy, crystal microbalance measu

  14. Focused beam reflectance measurement as a tool for in situ monitoring of the lactose crystallization process.

    Science.gov (United States)

    Pandalaneni, K; Amamcharla, J K

    2016-07-01

    Lactose accounts for about 75 and 85% of the solids in whey and deproteinized whey, respectively. Production of lactose is usually carried out by a process called crystallization. Several factors including rate of cooling, presence of impurities, and mixing speed influence the crystal size characteristics. To optimize the lactose crystallization process parameters to maximize the lactose yield, it is important to monitor the crystallization process. However, efficient in situ tools to implement at concentrations relevant to the dairy industry are lacking. The objective of the present work was to use a focused beam reflectance measurement (FBRM) system for in situ monitoring of lactose crystallization at supersaturated concentrations (wt/wt) 50, 55, and 60% at 20 and 30°C. The FBRM data were compared with Brix readings collected using a refractometer during isothermal crystallization. Chord length distributions obtained from FBRM in the ranges of crystals) and 50 to 300 µm (coarse crystals) were recorded and evaluated in relation to the extent of crystallization and rate constants deduced from the refractometer measurements. Extent of crystallization and rate constants increased with increasing supersaturation concentration and temperature. The measured fine crystal counts from FBRM increased at higher supersaturated concentration and temperature during isothermal crystallization. On the other hand, coarse counts were observed to increase with decreasing supersaturated concentration and temperature. Square weighted chord length distribution obtained from FBRM showed that as concentration increased, a decrease in chord lengths occurred at 20°C and similar observations were made from microscopic images. The robustness of FBRM in understanding isothermal lactose crystallization at various concentrations and temperatures was successfully assessed in the study. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Measuring parameters of large-aperture crystals used for generating optical harmonics

    Energy Technology Data Exchange (ETDEWEB)

    English, R. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hibbard, R. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Michie, R. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wegner, P. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Auerbach, J. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Norton, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Summers, M. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Perfect, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1999-02-23

    The purpose of this project was to develop tools for understanding the influence of crystal quality and crystal mounting on harmonic-generation efficiency at high irradiance. Measuring the homogeneity of crystals interferometrically, making detailed physics calculations of conversion efficiency, performing finite- element modeling of mounted crystals, and designing a new optical metrology tool were key elements in obtaining that understanding. For this work, we used the following frequency-tripling scheme: type I second- harmonic generation followed by type II sum-frequency mixing of the residual fundamental and the second harmonic light. The doubler was potassium dihydrogen phosphate (KDP), and the tripler was deuterated KDP (KD*P). With this scheme, near-infrared light (1053 nm) can be frequency tripled (to 351 nm) at high efficiency (theoretically >90%) for high irradiance (>3 GW/cm²). Spatial variations in the birefringence of the large crystals studied here (37 to 41 cm square by about 1 cm thick) imply that the ideal phase-matching orientation of the crystal with respect to the incident laser beam varies across the crystal. We have shown that phase-measuring interferometry can be used to measure these spatial variations. We observed transmitted wavefront differences between orthogonally polarized interferograms of {lambda}/50 to {lambda}/100, which correspond to index variations of order 10-6. On some plates that we measured, the standard deviation of angular errors is 22-23 µrad; this corresponds to a 1% reduction in efficiency. Because these conversion crystals are relatively thin, their surfaces are not flat (deviate by k2.5 urn from flat). A crystal is mounted against a precision-machined surface that supports the crystal on four edges. This mounting surface is not flat either (deviates by +2.5 µm from flat). A retaining flange presses a compliant element against the crystal. The load thus applied near the edges of the crystal surface holds

  16. A photoelastic measurement system for residual stress analysis in scintillating crystals by conoscopic imaging.

    Science.gov (United States)

    Montalto, L; Paone, N; Scalise, L; Rinaldi, D

    2015-06-01

    The assessment of the stress state of scintillating crystals is an important issue for producers as well as users of such materials, because residual stress may arise during growth process. In this paper, a measurement system, based on the use of a photoelastic, conoscopic optical setup, is proposed for the assessment of stress state in scintillating crystals. Local stress values can be measured on the crystal in order to observe their spatial distribution. With the proposed system, it is possible to vary the dimensions of the inspected measurement volume. It has been validated with reference to a known stress state induced in a birefringent crystal sample and it has been tested for the case of loaded and unloaded samples, showing sub-millimetric spatial resolution and stress uncertainty ≤0.25 MPa. The proposed measurement system is a valid method for the inspection of scintillating crystals required by producers and users of such materials.

  17. Potential-dependent adsorption/desorption behavior of perfluorosulfonated ionomer on a gold electrode surface studied by cyclic voltammetry, electrochemical quartz microbalance, and electrochemical atomic force microscopy.

    Science.gov (United States)

    Masuda, Takuya; Ikeda, Kota; Uosaki, Kohei

    2013-02-19

    Potential-dependent adsorption/desorption behavior of perfluorosulfonated ionomer (PFSI) on a gold electrode was investigated by cyclic voltammetry (CV), electrochemical quartz crystal microbalance (EQCM), and electrochemical atomic force microscopy (EC-AFM) in a Nafion (i.e., PFSI) dispersed aqueous solution without any other electrolyte. It was found that PFSI serves as an electrolyte and that electrochemical measurements can be performed in this solution without any significant IR drop. PFSI molecules were adsorbed on the Au surface in the lying-down configuration in the potential range between 0 and 0.45 V, the amount of adsorbed PFSI increased when the potential was made more positive than 0.75 V, and the adsorbed PFSI fully desorbed from the surface at potentials more positive than 1.4 V where gold oxide was formed. Once the gold oxide had been reduced, PFSI readsorbed on the surface, albeit slowly. PFSI desorbed from the surface as the potential was made more negative than 0 V. These processes took place reversibly.

  18. Measurement of pair-production by high energy photons in an aligned tungsten crystal

    Science.gov (United States)

    Moore, R.; Parker, M. A.; Baurichter, A.; Kirsebom, K.; Medenwaldt, R.; Mikkelsen, U.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Doble, N.; Elsener, K.; Ballestrero, S.; Sona, P.; Strakhovenko, V. M.; Biino, C.; Vilakazi, Z. Z.

    1996-10-01

    A new measurement has been made of the rate of pair-production in a 3.2 mm thick tungsten crystal, exposed to photons with energies in the range 10 to 150 GeV, for angles of incidence up to 10 mrad from the crystal axis. A strong enhancement of the pair-production rate is observed when the beam is aligned along the crystal axis, as compared to a random orientation. This effect can be exploited in the NA48 CP-violation experiment by using a thin crystal rather than an amorphous material to convert photons, thus minimising the scattering of kaons in the converter.

  19. Local phase measurements of light in a one-dimensional photonic crystal

    NARCIS (Netherlands)

    Flück, E.; Otter, A.M.; Korterik, J.P.; Balistreri, M.L.M.; Kuipers, L.; Hulst, van N.F.

    2001-01-01

    For the first time the local optical phase evolution in and around a small, o­ne-dimensional photonic crystal has been visualized with a heterodyne interferometric photon scanning tunnelling microscope. The measurements show an exponential decay of the optical intensity inside the crystal, which con

  20. Transmission measurement of the photonic band gap of GaN photonic crystal slabs

    NARCIS (Netherlands)

    Caro, J.; Roeling, E.M.; Rong, B.; Nguyen, H.M.; Van der Drift, E.W.J.M.; Rogge, S.; Karouta, F.; Van der Heijden, R.W.; Salemink, H.W.M.

    2008-01-01

    A high-contrast-ratio (30 dB) photonic band gap in the near-infrared transmission of hole-type GaN two-dimensional photonic crystals (PhCs) is reported. These crystals are deeply etched in a 650 nm thick GaN layer grown on sapphire. A comparison of the measured spectrum with finite difference time d

  1. Measurement and models of bent KAP(001) crystal integrated reflectivity and resolution (invited)

    Science.gov (United States)

    Loisel, G. P.; Wu, M.; Stolte, W.; Kruschwitz, C.; Lake, P.; Dunham, G. S.; Bailey, J. E.; Rochau, G. A.

    2016-11-01

    The Advanced Light Source beamline-9.3.1 x-rays are used to calibrate the rocking curve of bent potassium acid phthalate (KAP) crystals in the 2.3-4.5 keV photon-energy range. Crystals are bent on a cylindrically convex substrate with a radius of curvature ranging from 2 to 9 in. and also including the flat case to observe the effect of bending on the KAP spectrometric properties. As the bending radius increases, the crystal reflectivity converges to the mosaic crystal response. The X-ray Oriented Programs (xop) multi-lamellar model of bent crystals is used to model the rocking curve of these crystals and the calibration data confirm that a single model is adequate to reproduce simultaneously all measured integrated reflectivities and rocking-curve FWHM for multiple radii of curvature in both 1st and 2nd order of diffraction.

  2. Note: A miniature oscillating microbalance for sampling ice and volcanic ash from a small airborne platform.

    Science.gov (United States)

    Airey, M W; Harrison, R G; Nicoll, K A; Williams, P D; Marlton, G J

    2017-08-01

    A lightweight and low power oscillating microbalance for in situ sampling of atmospheric ice and volcanic ash is described for airborne platforms. Using a freely exposed collecting wire fixed at only one end to a piezo transducer, the instrument collects airborne materials. Accumulated mass is determined from the change in natural frequency of the wire. The piezo transducer is used in a dual mode to both drive and detect the oscillation. Three independent frequency measurement techniques are implemented with an on-board microcontroller: a frequency sweep, a Fourier spectral method, and a phase-locked loop. These showed agreement to ±0.3 Hz for a 0.5 mm diameter collecting wire of 120 mm long, flown to 19 km altitude on a weather balloon. The instrument is well suited to disposable use with meteorological radiosondes, to provide high resolution vertical profiles of mass concentration.

  3. Note: A miniature oscillating microbalance for sampling ice and volcanic ash from a small airborne platform

    Science.gov (United States)

    Airey, M. W.; Harrison, R. G.; Nicoll, K. A.; Williams, P. D.; Marlton, G. J.

    2017-08-01

    A lightweight and low power oscillating microbalance for in situ sampling of atmospheric ice and volcanic ash is described for airborne platforms. Using a freely exposed collecting wire fixed at only one end to a piezo transducer, the instrument collects airborne materials. Accumulated mass is determined from the change in natural frequency of the wire. The piezo transducer is used in a dual mode to both drive and detect the oscillation. Three independent frequency measurement techniques are implemented with an on-board microcontroller: a frequency sweep, a Fourier spectral method, and a phase-locked loop. These showed agreement to ±0.3 Hz for a 0.5 mm diameter collecting wire of 120 mm long, flown to 19 km altitude on a weather balloon. The instrument is well suited to disposable use with meteorological radiosondes, to provide high resolution vertical profiles of mass concentration.

  4. In-situ detection of growth striations by crystallization electromotive force measurement during Czochralski crystal growth

    Science.gov (United States)

    Zhu, Yunzhong; Ma, Decai; Long, Siwei; Tang, Feng; Lin, Shaopeng; Wang, Biao

    2017-10-01

    Growth striations, as macrodefects of crystalline materials, are mainly caused by convection and temperature fluctuations in growth interface. For decades, striations have been widely regarded as an inherent problem. Even in the well-developed Czochralski method, the striation formation process is difficult to inspect in situ. In view of this long-standing issue, after systematically studying the temperature, weight, and output power during crystal growth and numerically modeling the growth process, we found that the regularity of the growth interface electromotive force (GEMF) is related to the distribution of striations. Furthermore, the GEMF quantifies interface fluctuations (711.2 s, 16.6 μm) and thermal hysteresis (107 s), presenting finer details than those provided by a thermocouple and a load cell. In this paper, GEMF is found to be an outstanding choice for monitoring the crystal growth status in real time. As an additional feedback, a new automatic control method could be developed for reducing growth striations and promoting crystal quality.

  5. Real-time measurements of crystallization processes in viscoelastic polymeric photonic crystals.

    Science.gov (United States)

    Snoswell, David R E; Finlayson, Chris E; Zhao, Qibin; Baumberg, Jeremy J

    2015-11-01

    We present a study of the dynamic shear ordering of viscoelastic photonic crystals, based on core-shell polymeric composite particles. Using an adapted shear-cell arrangement, the crystalline ordering of the material under conditions of oscillatory shear is interrogated in real time, through both video imaging and from the optical transmission spectra of the cell. In order to gain a deeper understanding of the macroscopic influences of shear on the crystallization process in this solvent-free system, the development of bulk ordering is studied as a function of the key parameters including duty cycle and shear-strain magnitude. In particular, optimal ordering is observed from a prerandomized sample at shear strains of around 160%, for 1-Hz oscillations. This ordering reaches completion over time scales of order 10 s. These observations suggest significant local strains are needed to drive nanoparticles through energy barriers, and that local creep is needed to break temporal symmetry in such high-viscosity nanoassemblies. Crystal shear-melting effects are also characterized under conditions of constant shear rate. These quantitative experiments aim to stimulate the development of theoretical models which can deal with the strong local particle interactions in this system.

  6. A study on dual readout crystal calorimeter for hadron and jet energy measurement at a future lepton collider

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, G.P.; /Fermilab

    2010-01-01

    Studies of requirements and specifications of crystals are necessary to develop a new generation of crystals for dual readout crystal hadron or total absorption calorimeter. This is a short and basic study of the characteristics and hadron energy measurement of PbWO4 and BGO crystals for scintillation and Cerenkov Dual Readout hadron calorimeter.

  7. Ultrasonic crystallization monitoring technique for simultaneous in-line measurement of liquid and solid phase

    Science.gov (United States)

    Stelzer, T.; Pertig, D.; Ulrich, J.

    2013-01-01

    The mean crystal size, the suspension density and the liquid concentration are the three most important process parameters to quantify the progress of industrial crystallization processes. It will be shown that these parameters can be in-line monitored simultaneously by means of an ultrasonic crystallization monitoring technique (UCM), which will be introduced here in a proof of concept. This process analytical technology (PAT) differs from the known ultrasonic attenuation spectroscopy (UAS). For the UCM the ultrasonic velocity and attenuation were correlated and related to characteristic events during a crystallization process measured at only one frequency (no spectra of frequencies as it is used for UAS). The results shown in this study prepare the ground to establish the UCM as a simple, less complex, robust, universal applicable, inexpensive and, therefore, a winning alternative PAT to monitor and control in-line the solid as well as the liquid phase in the industrial crystallization by means of only one measuring device with two sensors.

  8. DC electrical conductivity measurements for pure and titanium oxide doped KDP Crystals grown by gel medium

    Science.gov (United States)

    Mareeswaran, S.; Asaithambi, T.

    2016-10-01

    Now a day's crystals are the pillars of current technology. Crystals are applied in various fields like fiber optic communications, electronic industry, photonic industry, etc. Crystal growth is an interesting and innovative field in the subject of physics, chemistry, material science, metallurgy, chemical engineering, mineralogy and crystallography. In recent decades optically good quality of pure and metal doped KDP crystals have been grown by gel growth method in room temperature and its characterizations were studied. Gel method is a very simple and one of the easiest methods among the various crystal growth methods. Potassium dihydrogen phosphate KH2PO4 (KDP) continues to be an interesting material both academically and technologically. KDP is a delegate of hydrogen bonded materials which possess very good electrical and nonlinear optical properties in addition to interesting electro-optic properties. We made an attempt to grow pure and titanium oxide doped KDP crystals with various doping concentrations (0.002, 0.004, 0.006, 0.008 and 0.010) using gel method. The grown crystals were collected after 20 days. We get crystals with good quality and shaped crystals. The dc electrical conductivity (resistance, capacitance and dielectric constant) values of the above grown crystals were measured at two different frequencies (1KHz and 100 Hz) with a temperature range of 500C to 1200C using simple two probe setup with Q band digital LCR meter present in our lab. The electrical conductivity increases with the increase of temperature. Dielectric constants value of titanium oxide doped KDP crystal was slightly decreased compared with pure KDP crystals. Results were discussed in details.

  9. Measurement of z-axis deviation angle of electro-optic crystal by conoscopic interference

    Science.gov (United States)

    Li, Dong; Liu, Yong; Liu, Xu; Jiang, Hongzhen; Zheng, Fanglan

    2016-09-01

    Properties of plasma electrode pockels cell is directly affected by the Z-axis deviation angle of the electro-optic crystal. Therefore, high precision measurement of the Z-axis deviation angle is indispensable. By using conoscopic interference technique, a measurement system for Z-axis deviation angle of electro-optic crystal is introduced. The principle of conoscopic interference method is described in detail, and a series of techniques are implied in this measurement system to improve the accuracy. High-precision positioning method of the crystal based on Michelson interference is proposed to determine the normal consistency of crystal, which can ensure the high positioning repeatability of crystal in the measurement process. The positioning comparison experiment of the crystal shows that the standard deviation of our method is less than 1pixel, which is much better than the traditional method (nearly 4pixels). Moreover, melatope extraction algorithm of optical axis based on image matching technique is proposed to ensure the melatope can be extracted in high precision. Calibration method of the normal of transmission surface of crystal is also proposed. The experiment results show that the PV and rms of Z-axis deviation angle is less than 0.05mrad and 0.02mrad, respectively. The repeatability accuracy is less than 0.01mrad.

  10. A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector

    CERN Document Server

    Martemianov, M; Demissie, B T; Marinides, Z; Akondi, C S; Annand, J R M; Arends, H J; Beck, R; Borisov, N; Braghieri, A; Briscoe, W J; Cherepnya, S; Collicott, C; Costanza, S; Downie, E J; Dieterle, M; Bondy, M I Ferretti; Filkov, L V; Garni, S; Glazier, D I; Glowa, D; Gradl, W; Gurevich, G; Hornidge, D; Huber, G M; Kaeser, A; Kashevarov, V L; Keshelashvili, I; Kondratiev, R; Korolija, M; Krusche, B; Lazarev, A; Linturi, J M; Lisin, V; Livingston, K; MacGregor, I J D; Manley, D M; Martel, P P; Middleton, D G; Miskimen, R; Mushkarenkov, A; Neganov, A; Neiser, A; Oberle, M; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Polonski, A; Prakhov, S; Ron, G; Rostomyan, T; Sarty, A; Schott, D M; Schumann, S; Sokhoyan, V; Steffen, O; Strakovsky, I I; Strub, Th; Supek, I; Thiel, M; Thomas, A; Unverzagt, M; Usov, Yu A; Wagner, S; Watts, D P; Wettig, J; Werthmuller, D; Witthauer, L; Wolfes, M

    2015-01-01

    We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single p0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.

  11. Calibration of the QCM/SAW Cascade Impactor for Measurement of Ozone

    Science.gov (United States)

    Williams, Cassandra K.; Peterson, C. B.; Morris, V. R.

    1997-01-01

    The Quartz Crystal Microbalance Surface Acoustic Wave (QCM/SAW) cascade impactor is an instrument designed to collect size-fractionated distributions of aerosols on a series of quartz crystals and employ SAW devices coated with chemical sensors for gas detection. We are calibrating the cascade impactor in our laboratory for future deployment for in-situ experiments to measure ozone. Experiments have been performed to characterize the QCM and SAW mass loading, saturation limits, mass frequency relationships, and sensitivity. The characteristics of mass loading, saturation limits, mass-frequency relationships, sensitivity, and the loss of ozone on different materials have been quantified.

  12. Correlation measurements of light transmittance in polymer dispersed liquid crystals

    Science.gov (United States)

    Maksimyak, P. P.; Nehrych, A. L.

    2015-11-01

    The methods of correlation optics are for the first time applied to study structure of liquid crystal (LC) - polymer (P) composites at various concentrations of LC and P. Their phase correlation function (PCF) was obtained considering LC-P composite as a random phase screen. The amplitude of PCF contains information about number of LC domains and structure of LC director inside of them, while a half-width of this function is connected with a size of these domains. We studied unpowered and powered composite layers with a thickness of 5 μm. As liquid crystal and polymer were used nematic LC E7 from Merck and photopolymer composition NOA65 from Norland. Concentration of polymer φP was varied in a range 10-55 vol. %. In good agreement with previous studies by SEM technique we detected monotone decrease of LC domains with concentration of polymer. With application of electric field, amplitude of PCF behaves differently for the samples with different polymer content. For the samples with φP>35 vol. % (samples having morphology of polymer dispersed LC), this dependence is monotonic. In turn, if φPLC morphology), the amplitude of PCF non-monotonically depends on the applied voltage going through a maximum. The latter fact is explained by transformation of orientational defects of LC phase with the applied voltage.

  13. Crystal Fields in Dilute Rare-Earth Metals Obtained from Magnetization Measurements on Dilute Rare-Earth Alloys

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.

    1974-01-01

    Crystal field parameters of Tb, Dy, and Er in Sc, Y, and Lu are summarized. These parameters are obtained from magnetization measurements on dilute single crystals, and successfully checked by a number of different methods. The crystal field parameters vary unpredictably with the rare-earth solute....... B40, B60, and B66 are similar in Y and Lu. Crystal field parameters for the pure metals Tb, Dy, and Er are estimated from the crystal fields in Y and Lu....

  14. In-situ measurement of bound states in the continuum in photonic crystal slabs (Conference Presentation)

    Science.gov (United States)

    Kalchmair, Stefan; Gansch, Roman; Genevet, Patrice; Zederbauer, Tobias; MacFarland, Donald; Detz, Hermann; Andrews, Aaron Maxwell; Schrenk, Werner; Strasser, Gottfried; Capasso, Federico; Loncar, Marko

    2016-04-01

    Photonic crystal slabs have been subject to research for more than a decade, yet the existence of bound states in the radiation continuum (BICs) in photonic crystals has been reported only recently [1]. A BIC is formed when the radiation from all possible channels interferes destructively, causing the overall radiation to vanish. In photonic crystals, BICs are the result of accidental phase matching between incident, reflected and in-plane waves at seemingly random wave vectors [2]. While BICs in photonic crystals have been discussed previously using reflection measurements, we reports for the first time in-situ measurements of the bound states in the continuum in photonic crystal slabs. By embedding a photodetector into a photonic crystal slab we were able to directly observe optical BICs. The photonic crystal slabs are processed from a GaAs/AlGaAs quantum wells heterostructure, providing intersubband absorption in the mid-infrared wavelength range. The generated photocurrent is collected via doped contact layers on top and bottom of the suspended photonic crystal slab. We were mapping out the photonic band structure by rotating the device and by acquiring photocurrent spectra every 5°. Our measured photonic bandstructure revealed several BICs, which was confirmed with a rigorously coupled-wave analysis simulation. Since coupling to external fields is suppressed, the photocurrent measured by the photodetector vanishes at the BIC wave vector. To confirm the relation between the measured photocurrent and the Q-factor we used temporal coupled mode theory, which yielded an inverse proportional relation between the photocurrent and the out-coupling loss from the photonic crystal. Implementing a plane wave expansion simulation allowed us to identify the corresponding photonic crystal modes. The ability to directly measure the field intensity inside the photonic crystal presents an important milestone towards integrated opto-electronic BIC devices. Potential

  15. Crystallization Study of Cu56Zr7Ti37 Metallic Glass by Electrical Resistivity Measurement

    Institute of Scientific and Technical Information of China (English)

    Ansu J. Kailath; Kalpalata Dutta; Thomas C.Alex; Amitava Mitra

    2011-01-01

    In this paper, the crystallization behaviour of amorphous Cu56Zr7Ti37alloy using thermal electrical resistivity (TER) and differential scanning calorimetry (DSC) studies has been described. Isochronal TER and DSC measurements indicate that crystallization occurs in two stages. Isothermal crystallization studies of the alloy by TER show that the kinetics conforms to Johnson-Mehl-Avrami model. Avrami exponents derived from kinetics, between 1.1 and 1.2, imply that the crystallization processes are diffusion controlled with near zero nucleation. Activation energy has been found to increase with the transformed volume fraction. A plausible explanation has been presented by separating the contributions due to nucleation and crystal growth towards total activation energy.

  16. Magnetic Field Measurements Based on Terfenol Coated Photonic Crystal Fibers

    Directory of Open Access Journals (Sweden)

    Carla C. Kato

    2011-11-01

    Full Text Available A magnetic field sensor based on the integration of a high birefringence photonic crystal fiber and a composite material made of Terfenol particles and an epoxy resin is proposed. An in-fiber modal interferometer is assembled by evenly exciting both eigenemodes of the HiBi fiber. Changes in the cavity length as well as the effective refractive index are induced by exposing the sensor head to magnetic fields. The magnetic field sensor has a sensitivity of 0.006 (nm/mT over a range from 0 to 300 mT with a resolution about ±1 mT. A fiber Bragg grating magnetic field sensor is also fabricated and employed to characterize the response of Terfenol composite to the magnetic field.

  17. Magnetic field measurements based on Terfenol coated photonic crystal fibers.

    Science.gov (United States)

    Quintero, Sully M M; Martelli, Cicero; Braga, Arthur M B; Valente, Luiz C G; Kato, Carla C

    2011-01-01

    A magnetic field sensor based on the integration of a high birefringence photonic crystal fiber and a composite material made of Terfenol particles and an epoxy resin is proposed. An in-fiber modal interferometer is assembled by evenly exciting both eigenemodes of the HiBi fiber. Changes in the cavity length as well as the effective refractive index are induced by exposing the sensor head to magnetic fields. The magnetic field sensor has a sensitivity of 0.006 (nm/mT) over a range from 0 to 300 mT with a resolution about ±1 mT. A fiber Bragg grating magnetic field sensor is also fabricated and employed to characterize the response of Terfenol composite to the magnetic field.

  18. Application of the TEOM reactor for adsorption, diffusion and kinetic studies[TEOM=Tapered Element Oscillating Microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Rebo, Hans Petter

    1999-07-01

    In Norway, the limited offshore oil resources, the abundance of natural gas and the need to recover associated gas from the crude oil production have made the utilisation of natural gas the focus of increased attention. Most products from refineries and chemical industry are formed by gas phase reactions over solid materials like metals, metal oxides and zeolites. Heterogeneous catalysts are in addition frequently used for environmental purposes and energy production. In the work described in this thesis, an experimental set-up was built and used to study some typical processes in heterogeneous catalysis. The set-up included a tapered element oscillating microbalance (TEOM) for measuring mass changes. The following properties of the TEOM were found particularly useful: (1) Frequent frequency counting makes the TEOM suitable for recording transient uptake curves, (2) High sensitivity of the microbalance makes it possible to work with low catalyst loading and still obtain high signal to noise ratio, and (3) Reliable kinetic data are obtained due to the fixed bed characteristics of the TEOM. Adsorption and diffusion of o-xylene and toluene in a commercial HZSM-5 zeolite were studied at 30, 100 and 200 {sup o}C and at partial pressures in the range of 0.002-0.1 bar. The effect of coke on the adsorption and diffusion properties were studied by adsorption experiments at 30 {sup o}C of ethane, toluene and n-hexane before and after coke formation during ethene oligomerisation at 475 {sup o}C and at P(ethene)=0.8 bar. The oligomerisation of ethene over HZSM-5 was used as a model reaction for comparing coke formation in a gravimetric microbalance and in the TEOM. The work also includes a study of coke formation and the effect of coke on the kinetics of propene dehydrogenation over Pt-Sn/Al{sub 2}O{sub 3} catalysts at 500-580 {sup o}C.

  19. Local Refractive Index Measurements at Low Temperatures using Photonic Crystal Cavities

    CERN Document Server

    Wolters, Janik; Schoengen, Max; Schell, Andreas W; Probst, Jürgen; Löchel, Bernd; Benson, Oliver

    2012-01-01

    Photonic crystal cavities have a wide range of applications in physics today. Here we demonstrate a method to use the narrow resonances of photonic crystal cavities to measure the temperature dependence of the refractive index of gallium phosphide in a temperature range between 5 K and near room temperature at a wavelength of about 605 nm. On one hand, this is an essential step for the design of GaP photonic crystal structures for quantum technology applications. On the other hand, this demonstrates how photonic structures can be utilized to locally determine the optical properties of semiconductor materials in attoliter volumina.

  20. Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, M. J.; Jacoby, K. D.; Ross, P. W. [National Security Technologies, LLC, Livermore, California 94551 (United States); Regan, S. P.; Magoon, J.; Shoup, M. J. III [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Barrios, M. A.; Emig, J. A.; Fournier, K. B. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    The elliptically curved pentaerythritol (PET) crystals used in the Supersnout 2 x-ray spectrometer on the National Ignition Facility at Lawrence Livermore National Laboratory have been calibrated photometrically in the range of 5.5-16 keV. The elliptical geometry provides broad spectral coverage and minimizes the degradation of spectral resolution due to the finite source size. The reflectivity curve of the crystals was measured using a x-ray line source. The integrated reflectivity (R{sub I}) and width of its curve ({Delta}{Theta}) were the measurements of major interest. The former gives the spectrometer throughput, and the latter gives the spectrometer resolving power. Both parameters are found to vary considerably with the radius of curvature of the crystal and with spectral energy. The results are attributed to an enhanced mosaic effect due to the increase in curvature. There are also contributions from the crystal cleaving and gluing processes.

  1. Measurement of neutron detection efficiencies in NaI using the Crystal Ball detector

    Energy Technology Data Exchange (ETDEWEB)

    Stanislaus, T.D.S.; Koetke, D.D. E-mail: donald.koetke@valpo.edu; Allgower, C.; Bekrenev, V.; Benslama, K.; Berger, E.; Briscoe, W.J.; Clajus, M.; Comfort, J.R.; Craig, K.; Gibson, A.; Grosnick, D.; Huber, G.M.; Isenhower, D.; Kasprzyk, T.; Knecht, N.; Koulbardis, A.; Kozlenko, N.; Kruglov, S.; Kycia, T.; Lolos, G.J.; Lopatin, I.; Manley, D.M.; Manweiler, R.; Marusic, A.; McDonald, S.; Nefkens, B.M.K.; Olmsted, J.; Papandreou, Z.; Peaslee, D.; Peterson, R.J.; Phaisangittisakul, N.; Pulver, M.; Ramirez, A.F.; Sadler, M.; Shafi, A.; Slaus, I.; Spinka, H.; Starostin, A.; Staudenmaier, H.M.; Supek, I.; Thoms, J.; Tippens, W.B

    2001-04-21

    We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball (CB) detector obtained from a study of {pi}{sup -}p{yields}{pi} degree sign n reactions at the Brookhaven National Laboratory AGS. A companion GEANT-based Monte Carlo study has been done to simulate these reactions in the CB, and a comparison with the data is provided.

  2. Measurement of neutron detection efficiencies in NaI using the Crystal Ball detector

    Science.gov (United States)

    Stanislaus, T. D. S.; Koetke, D. D.; Allgower, C.; Bekrenev, V.; Benslama, K.; Berger, E.; Briscoe, W. J.; Clajus, M.; Comfort, J. R.; Craig, K.; Gibson, A.; Grosnick, D.; Huber, G. M.; Isenhower, D.; Kasprzyk, T.; Knecht, N.; Koulbardis, A.; Kozlenko, N.; Kruglov, S.; Kycia, T.; Lolos, G. J.; Lopatin, I.; Manley, D. M.; Manweiler, R.; Marusic, A.; McDonald, S.; Nefkens, B. M. K.; Olmsted, J.; Papandreou, Z.; Peaslee, D.; Peterson, R. J.; Phaisangittisakul, N.; Pulver, M.; Ramirez, A. F.; Sadler, M.; Shafi, A.; Slaus, I.; Spinka, H.; Starostin, A.; Staudenmaier, H. M.; Supek, I.; Thoms, J.; Tippens, W. B.

    2001-04-01

    We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball (CB) detector obtained from a study of π-p→ π°n reactions at the Brookhaven National Laboratory AGS. A companion GEANT-based Monte Carlo study has been done to simulate these reactions in the CB, and a comparison with the data is provided.

  3. Electrical conductivity measurements on gel grown KDP crystals added with urea and thiourea

    Indian Academy of Sciences (India)

    M Priya; C M Padma; T H Freeda; C Mahadevan; C Balasingh

    2001-10-01

    Pure and impurity added (with urea and thiourea) KDP single crystals were grown by the gel method using silica gels. Electrical conductivity measurements were carried out along both the unique axis and perpendicular directions at various temperatures ranging from 30 to 140°C by the conventional two-probe method. The present study shows that the conductivity in KDP crystals, for both the impurities considered, increases with the increase in impurity concentration and temperature. Activation energies were also determined and reported.

  4. Measurement and analysis of the mannitol partition coefficient in sucrose crystallization under simulated industrial conditions.

    Science.gov (United States)

    Eggleston, Gillian; Yen, Jenny Wu Tiu; Alexander, Clay; Gober, Jessica

    2012-07-01

    Mannitol is a major deterioration product of Leuconstoc mesenteroides bacterial metabolism of sucrose and fructose from both sugarcane and sugar beet. The effect of crystallization conditions on the mannitol partition coefficient (K(eff)) between impure sucrose syrup and crystal has been investigated in a batch laboratory crystallizer and a batch pilot plant-scale vacuum pan. Laboratory crystallization was operated at 65.5°C (150°F), 60.0°C (140°F), and 51.7°C (125°F) with a 78.0 Brix (% refractometric dissolved solids) pure sucrose syrup containing 0%, 0.1%, 0.2%, 1.0%, 2.0%, 3.0%, and 10% (at 65.5°C only) mannitol on a Brix basis. Produced mother liquor and crystals were separated by centrifugation and their mannitol contents measured by ion chromatography with integrated pulsed amperometric detection (IC-IPAD). The extent of mannitol partitioning into the crystals depended strongly on the mannitol concentration in the feed syrup and, to a lesser extent, the crystallization temperature. At 65.5 and 60.0°C, the K(eff) varied from ~0.4% to 3.0% with 0.2% to 3.0% mannitol in the feed syrup, respectively. The mannitol K(eff) was lower than that reported for dextran (~9-10% K(eff)), another product of Leuconstoc deterioration, under similar sucrose crystal growth conditions. At 10% mannitol concentration in the syrup at 65.5°C, co-crystallization of mannitol with sucrose occurred and the crystal growth rate was greatly impeded. In both laboratory and pilot plant crystallizations (95.7% purity; 78.0 Brix; 65.5°C), mannitol tended to cause conglomerates to form, which became progressively worse with increased mannitol syrup concentration. At the 3% mannitol concentration, crystallization at both the laboratory and pilot plant scales was more difficult. Mannitol incorporation into the sucrose crystal results mostly from liquid syrup inclusions but adsorption onto the crystal surface may play a minor role at lower mannitol concentrations.

  5. An asymmetric resonant coupling wireless power transmission link for Micro-Ball Endoscopy.

    Science.gov (United States)

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Ziqiang; Wang, Zhihua

    2010-01-01

    This paper investigates the design and optimization of a wireless power transmission link targeting Micro-Ball Endoscopy applications. A novel asymmetric resonant coupling structure is proposed to deliver power to an endoscopic Micro-Ball system for image read-out after it is excreted. Such a technology enables many key medical applications with stringent requirements for small system volume and high power delivery efficiency. A prototyping power transmission sub-system of the Micro-Ball system was implemented. It consists of primary coil, middle resonant coil, and cube-like full-direction secondary receiving coils. Our experimental results proved that 200mW of power can be successfully delivered. Such a wireless power transmission capability could satisfy the requirements of the Micro-Ball based endoscopy application. The transmission efficiency is in the range of 41% (worst working condition) to 53% (best working condition). Comparing to conventional structures, Asymmetric Resonant Coupling Structure improves power efficiency by 13%.

  6. Micro-Ball Lens Array Fabrication in Photoresist Using Ptfe Hydrophobic Effect

    CERN Document Server

    Shyu Ruey Fang; Tsai Wen Ren; Tsai Jhy Cherng

    2007-01-01

    This paper presents a simple method to fabricate micro-ball lens and its array. The key technology is to use the hydrophobic characteristics of polyterafluoroethylene (PTFE) substrate. High contact angle between melted photoresist pattern and PTFE can generate micro-ball lens and its array. PTFE thin film was spun onto a silicon wafer and dried in oven. Photoresist AZ4620 was used to pattern micro-columns with different diameters 60, 70 and 80 $\\mu$m. A thermal reflow process then was applied to melt these micro-column patterns resulted in micro-ball lens array. The achieved micro-ball lens array with diameter 98 $\\mu$m was fabricated using 80 $\\mu$m in diameter patterns. This method provides a simple fabrication process and low material cost.

  7. Absolute measurement of the effective nonlinearities of KTP and BBO crystals by optical parametric amplification.

    Science.gov (United States)

    Armstrong, D J; Alford, W J; Raymond, T D; Smith, A V

    1996-04-20

    Absolute magnitudes of the effective nonlinearity, deff, were measured for seven KTP and six BBO crystals. The d(eff), were derived from the parametric gain of an 800-nm signal wave in the sample crystals when they were pumped by the frequency-doubled, spatially filtered light from an injectionseeded, Q-switched Nd:YAG laser. The KTP crystals, all type II phase matched with propagation in the X-Z plane, had d(eff) values ranging from 1.97 to 3.50 pm/V. Measurements of gain as a function of phase velocity mismatch indicate that two of the KTP crystals clearly contain multiple ferroelectric domains. For five type I phase-matched BBO crystals, d(eff) ranged from 1.76 to 1.83 pm/V, and a single type II phase-matched BBO crystal had a d(eff) of 1.56 pm/V. The uncertainty in our measurements of d(eff) values is ±5% for KTP and ±10% for BBO.

  8. Crystal fields of dilute Tb, Dy, or Er in Sc obtained by magnetization measurements

    DEFF Research Database (Denmark)

    Høg, J.; Touborg, P.

    1976-01-01

    Crystal-field parameters for dilute Sc-Tb, Sc-Dy, and Sc-Er alloys have been obtained by fitting theoretical expressions to the experimentally measured paramagnetic susceptibility. The initial susceptibility was measured and corrected for the effects of ordering at the lowest temperatures in the ...

  9. Some effects of ice crystals on the FSSP measurements in mixed phase clouds

    Directory of Open Access Journals (Sweden)

    G. Febvre

    2012-10-01

    Full Text Available In this paper, we show that in mixed phase clouds, the presence of ice crystals may induce wrong FSSP 100 measurements interpretation especially in terms of particle size and subsequent bulk parameters. The presence of ice crystals is generally revealed by a bimodal feature of the particle size distribution (PSD. The combined measurements of the FSSP-100 and the Polar Nephelometer give a coherent description of the effect of the ice crystals on the FSSP-100 response. The FSSP-100 particle size distributions are characterized by a bimodal shape with a second mode peaked between 25 and 35 μm related to ice crystals. This feature is observed with the FSSP-100 at airspeed up to 200 m s−1 and with the FSSP-300 series. In order to assess the size calibration for clouds of ice crystals the response of the FSSP-100 probe has been numerically simulated using a light scattering model of randomly oriented hexagonal ice particles and assuming both smooth and rough crystal surfaces. The results suggest that the second mode, measured between 25 μm and 35 μm, does not necessarily represent true size responses but corresponds to bigger aspherical ice particles. According to simulation results, the sizing understatement would be neglected in the rough case but would be significant with the smooth case. Qualitatively, the Polar Nephelometer phase function suggests that the rough case is the more suitable to describe real crystals. Quantitatively, however, it is difficult to conclude. A review is made to explore different hypotheses explaining the occurrence of the second mode. However, previous cloud in situ measurements suggest that the FSSP-100 secondary mode, peaked in the range 25–35 μm, is likely to be due to the shattering of large ice crystals on the probe inlet. This finding is supported by the rather good relationship between the concentration of particles larger than 20 μm (hypothesized to be ice shattered-fragments measured by the

  10. Measuring anisotropic resistivity of single crystals using the van der Pauw technique

    OpenAIRE

    2015-01-01

    Anisotropy in properties of materials is important in materials science and solid-state physics. Measurement of the full resistivity tensor of crystals using the standard four-point method with bar shaped samples requires many measurements and may be inaccurate due to misalignment of the bars along crystallographic directions. Here an approach to extracting the resistivity tensor using van der Pauw measurements is presented. This reduces the number of required measurements. The theory of the ...

  11. Use of a hexapod in diffraction measurements of substrate-supported crystals of organic semiconductors.

    Science.gov (United States)

    Yang, Lin; Yang, Hoichang

    2009-11-01

    Thin films of organic semiconductor prepared on substrates generally contain crystals that have one common crystal plane parallel to the substrate but random in-plane orientations. In diffraction measurements of these structures, it is often required to anchor the X-ray beam on a fixed spot on the sample, such as an optically visible crystallite or island. Here, a hexapod is used in place of a traditional multi-circle diffractometer to perform area-detector-based diffraction measurements on an actual device that contains 6,13-bis(triisopropyl-silyethynyl)-pentacene (TIPS-pentacene) crystals. The hexapod allows for sample rotations about any user-defined rotation center. Two types of complex sample motions have been programmed to characterize the structure of the TIPS-pentacene crystal: an in-plane powder average has been performed at a fixed grazing-incident angle to determine the lattice parameters of the crystal; then the in-plane component of the scattering vector was continuously rotated in transmission geometry to determine the local crystal orientation.

  12. Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI

    Science.gov (United States)

    Schmall, Jeffrey P.; Surti, Suleman; Karp, Joel S.

    2015-05-01

    A PET detector with good timing resolution and two-level depth-of-interaction (DOI) discrimination can be constructed using a single-ended readout of scintillator stacks of Lanthanum Bromide (LaBr3), with various Cerium dopant concentrations, including pure Cerium Bromide (CeBr3). The stacked crystal geometry creates a unique signal shape for interactions occurring in each layer, which can be used to identify the DOI, while retaining the inherently good timing properties of LaBr3 and CeBr3. In this work, single pixel elements are used to optimize the choice of scintillator, coupling of layers, and type of photodetector, evaluating the performance using a fast, single-channel photomultiplier tube (PMT) and a single 4 × 4 mm2 silicon photomultiplier (SiPM). We also introduce a method to quantify and evaluate the DOI discrimination accuracy. From signal shape measurements using fast waveform sampling, we found that in addition to differences in signal rise times, between crystal layers, there were also differences in the signal fall times. A DOI accuracy of 98% was achieved using our classification method for a stacked crystal pair, consisting of a 15 mm long LaBr3(Ce:20%) crystal on top of a 15 mm long CeBr3 crystal, readout using a PMT. A DOI accuracy of 95% was measured with a stack of two, identical, 12 mm long, CeBr3 crystals. The DOI accuracy of this crystal pair was reduced to 91% when using a SiPM for readout. For the stack of two, 12 mm long, CeBr3 crystals, a coincidence timing resolution (average of timing results from the top and bottom layer) of 199 ps was measured using a PMT, and this was improved to 153 ps when using a SiPM. These results show that with stacked LaBr3/CeBr3 scintillators and fast waveform sampling nearly perfect DOI accuracy can be achieved with excellent timing resolution—timing resolution that is only minimally degraded compared to results from a single CeBr3 crystal of comparable length to the stacked crystals. The

  13. The construction, prediction and measurement of co-crystal ternary phase diagrams as a tool for solvent selection.

    Science.gov (United States)

    Holaň, Jan; Stěpánek, František; Billot, Pascal; Ridvan, Luděk

    2014-10-15

    Many active pharmaceutical ingredients (APIs) are poorly soluble and therefore poorly bioavailable. In recent years, the advances in crystal engineering have motivated the research in the design of pharmaceutical co-crystals. This study examines the combination of solvent selection and co-crystal ternary phase diagram prediction on the basis of solubility measurements into a single methodology that can be integrated into the pharmaceutical process development workflow. Ternary diagrams constructed from agomelatine citric acid co-crystal solubility data were compared with those obtained by modern calorimetric method called discontinuous isoperibolic thermal analysis (DITA). A suitable solvent for the co-crystallization process has been chosen on the basis of agomelatine citric acid co-crystal solubility, which is connected to the yield of the crystallization process. Furthermore, the quality of final crystals from crystallization experiments was evaluated.

  14. Determination of resistance to salt crystallization on natural stone measured with ultrasonic wave

    DEFF Research Database (Denmark)

    Alm, D.; Brix, S.; Kjærgaard, H. Howe

    2008-01-01

    The use of panels as facade cladding has increased substantially during the last few decades. However, during recent years reports of facade problems have increased dramatically. Facade cladding has, in some cases, suffered from problems with durability such as exfoliation, disintegration of macr...... porosity while Perlatino has 1.1 % in open porosity. By means of ultrasonic measurements it is possible to detect damage in stones exposed to salt crystallization cycles. The results show a tendency to less resistance of salt crystallization for more porous materials....... of macrostructure and loss of strength. The damage may to some extent be accelerated by salt crystallization. This is an investigation of the durability of stones exposed to salt crystallization, by means of ultrasonic velocity measurements, compressive strength measurements and analysis of thin sections before...... and after salt exposure. Four different stones are investigated: the limestone Bateig Azul, the sandstone Oberkirchener, the limestone Perlatino, and the limestone Travertine. The procedure for the salt crystallization test is EN 12370 standard “Natural stone test methods – Determination of resistance...

  15. Quartz Microbalance Sensor for the Detection of Acrylamide

    Directory of Open Access Journals (Sweden)

    Christoph A. Schalley

    2004-10-01

    Full Text Available Abstract: Several macrocycles of the Hunter-Vögtle type have been identified as superior host compounds for the detection of small amounts of acrylamide. When coated onto the surface of a quartz microbalance, these compounds serve as highly sensitive and selective sensor-active layers for their use in electronic noses. In this study, differently substituted macrocycles were investigated including an open-chain analogue and a catenane. Their structure and functional groups are correlated with their observed affinities to acrylamide and related acids and amides. The much smaller response of the open-chain compound and the almost absent sensor response of the catenane suggest that binding occurs within the cavity of the macrocycle. Theoretical calculations agree well with the experimental data even though they do not yet take into account the arrangement of the macrocycles in the sensor-active layer. The lower detection limit of acrylamide is 10 parts per billion (ppb, which is impressively low for this type of sensor. Other related compounds such as acrylic acid, propionamide, or propionic acid show no or significantly lower affinities to the macrocycles in these concentration ranges.

  16. AC and DC Electrical Conductivity Measurements on Glycine Family of Nonlinear Optical (NLO Single Crystals

    Directory of Open Access Journals (Sweden)

    Suresh Sagadevan

    2014-04-01

    Full Text Available In the present work, the AC/DC conductivity studies were carried out on Glycine family of NLO single crystals such as Trisglycine Zinc Chloride (TGZC, Triglycine Acetate (TGAc and Glycine Lithium Sulphate (GLS. The AC conductivity measurements were carried out using HIOKI 3532-50 LCR HITESTER in the frequency range of 50 Hz to 5 MHz for the grown NLO single crystals. The DC electrical conductivity measurements were also carried out for the crystals using the conventional two – probe technique in the temperature range of 313 – 423 K. The present study indicates that both the AC and DC conductivity of the samples increase with the increase in temperature. The activation energies were also calculated from AC/DC conductivity studies.

  17. THERMAL LENSING MEASUREMENTS IN THE ANISOTROPIC LASER CRYSTALS UNDER DIODE PUMPING

    Directory of Open Access Journals (Sweden)

    P. A. Loiko

    2012-01-01

    Full Text Available An experimental setup was developed for thermal lensing measurements in the anisotropic diode-pumped laser crystals. The studied crystal is placed into the stable two-mirror laser cavity operating at the fundamental transversal mode. The output beam radius is measured with respect to the pump intensity for different meridional planes (all these planes contain the light propagation direction. These dependencies are fitted using the ABCD matrix method in order to obtain the sensitivity factors showing the change of the optical power of thermal lens due to variation of the pump intensity. The difference of the sensitivity factors for two mutually orthogonal principal meridional planes describes the thermal lens astigmatism degree. By means of this approach, thermal lensing was characterized in the diode-pumped monoclinic Np-cut Nd:KGd(WO42 laser crystal at the wavelength of 1.067 μm for light polarization E || Nm.

  18. Electrical and thermoelectric power measurements of GaInSe{sub 2} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Mobarak, M., E-mail: moustafff@yahoo.co [Physics Department, Faculty of Science, South Valley University, Qena (Egypt)

    2009-05-01

    A single crystal of GaInSe{sub 2} was prepared from melt using a vertical Bridgman technique. The crystal was characterized by X-ray diffraction and Energy dispersive X-ray fluorescence spectrometer (EDXRF). Electrical conductivity, hall effect, and thermoelectric power (TEP) measurements were performed in the temperature range from 120 to 570 K. Throughout these measurements, various physical parameters such as carrier mobilities, effective masses of charge carriers, diffusion coefficient, relaxation time, and the diffusion length for both majority and minority carriers were estimated. In conjunction with the electrical conductivity and the charge carrier concentration, the TEP is discussed. All crystals were found to be of p-type conductivity.

  19. On-line digital holographic measurement of size and shape of microparticles for crystallization processes

    Science.gov (United States)

    Khanam, Taslima; Darakis, Emmanouil; Rajendran, Arvind; Kariwala, Vinay; Asundi, Anand K.; Naughton, Thomas J.

    2008-09-01

    Crystallization is a widely used chemical process that finds applications in pharmaceutical industries. In an industrial crystallization process, it is not only important to produce pure crystals but also to control the shape and size of the crystals, as they affect the efficiency of downstream processes and the dissolution property of the drug. The effectiveness of control algorithms depend on the availability of on-line, real-time information about these critical properties. In this paper, we investigate the use of lens-less in-line digital holographic microscopy for size and shape measurements for crystallization processes. For this purpose, we use non-crystalline spherical microparticles and carbon fibers with known sizes present in a liquid suspension as test systems. We propose an algorithm to extract size and shape information for a population of microparticles from the experimentally recorded digital holograms. The measurements obtained from the proposed method show good agreement with the corresponding known size and shape of the particles.

  20. Record Deflection Efficiencies Measured for High Energy Protons in a Bent Germanium Crystal

    Science.gov (United States)

    Elsener, K.; Biino, C.; Clement, M.; Doble, N.; Gatignon, L.; Grafstrom, P.; Mikkelsen, U.; Kirsebom, K.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Freund, A.

    1997-05-01

    New experimental results on the deflection of 450 GeV/c and 200 GeV/c protons in a bent Ge crystal are presented. At 450 GeV/c, the 50 mm long crystal gave record deflection efficiencies up to 60% for small angles (1 mrad), while at angles as large as 12 mrad, the efficiency is about 25 times larger than for a silicon crystal of the same size. Measurements up to 20 mrad deflection angle have been performed at 200 GeV/c as well as 450 GeV/c - the lower bending dechanneling leads to a rather slow decrease in efficiency at lower momenta, and 15% of the 200 GeV/c beam hitting the crystal are still deflected at the largest angles measured. These experimental results are in good agreement with a model for channeling deflection developed by Ellison and give confidence in extrapolations to higher energies (e.g. to LHC), other crystal materials or different deflection angles.

  1. Apparatus for measuring the permeability of crystal particles suspended in a slurry

    NARCIS (Netherlands)

    Diepen, P.J.; Vreeken, V.P.C.

    1998-01-01

    The invention relates to an apparatus for measuring the permeability of crystal particles suspended in a slurry, comprising a filtering element (3) and driving means (4, 5, 6) for driving the slurry into the filtering element. The filtering element is connected with discharge means (8, 9) for the

  2. Measurement of the linear electro-optic tensor of cubic boron nitride single crystals

    Institute of Scientific and Technical Information of China (English)

    Shuang Wang; Gang Jia; Xiuhuan Liu; Shipeng Chi; Jingcheng Zhu; Yanjun Gao; Pingwei Zhou; Zhanguo Chen

    2012-01-01

    The transverse electro-optic (EO) modulation system is built based on cubic boron nitride (cBN) single crystals unintentionally doped and synthesized at a high pressure and high temperature.The photoelectric output of the system includes two parts that can be measured respectively and the value of elements in the linear EO tensor of the cBN crystal can be obtained.This method does not need to measure the absolute light intensity.All of the surfaces of the tiny cBN crystals whose hardness is next to the hardest diamonds are {111} planes.The rectangular parallelepiped cBN samples are obtained by cleaving along {110} planes and subsequently grinding and polishing {112} planes of the tiny octahedral cBN flakes.Three identical non-zero elements of the EO tensor of the cBN crystal are measured via two sample configurations,and the measured results are very close,about 3.68 and 3.95 pm/V,respectively,which are larger than the linear EO coefficients of the general Ⅲ-Ⅴ compounds.

  3. Measuring birefringence of curved sheet and single crystals by double-exposure speckle photography

    Science.gov (United States)

    El-Dessouki, T. A.; Hendawy, N. I.; Zaki, A. A.

    2009-06-01

    In this work, a new theoretical and experimental approach for measuring birefringence of solid materials was described. Dispersions of birefringence of quartz, calcite crystals and Fortypan sheet were determined in the visible region. The results were compared with other interferometric methods to verify the accuracy of this approach.

  4. A statistical approach for measuring dislocations in 2D photonic crystals

    DEFF Research Database (Denmark)

    Malureanu, Radu; Frandsen, Lars Hagedorn

    2008-01-01

    In this paper, a comparison between the placement accuracy of lattice atoms in photonic crystal structures fabricated with different lithographic techniques is made. Using atomic force microscopy measurements and self-developed algorithms for calculating the holes position within less than 0.01nm...

  5. The Measurement of Electron-Induced Erosion of Condensed Gases: Experimental Methods

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Børgesen, P.

    1984-01-01

    Two experimental methods for measuring the erosion yield of condensed gases are described. One, the frequency-change method, utilizes a quartz-crystal microbalance operating at liquid-helium temperature. The other, the emissivity-change method is based on the strongly varying electron emission...... as a function of the condensed-gas film thickness. Satisfactory results have been obtained for both methods for solid Ne and D2 at electron energies up to 3 keV, and the mutual agreement is good as well. Accurate measurements are affected critically by the beam conditions, particularly if the erosion yield...

  6. Single-Crystal Elastic Constants of Yttria (Y2O3) Measured to High Temperatures

    Science.gov (United States)

    Sayir, Ali; Palko, James W.; Kriven, Waltraud M.; Sinogeikin, Sergey V.; Bass, Jay D.

    2001-01-01

    Yttria, or yttrium sesquioxide (Y2O3), has been considered for use in nuclear applications and has gained interest relatively recently for use in infrared optics. Single crystals of yttria have been grown successfully at the NASA Glenn Research Center using a laser-heated float zone technique in a fiber and rod. Such samples allow measurement of the single-crystal elastic properties, and these measurements provide useful property data for the design of components using single crystals. They also yield information as to what degree the elastic properties of yttria ceramics are a result of the intrinsic properties of the yttria crystal in comparison to characteristics that may depend on processing, such as microstructure and intergranular phases, which are common in sintered yttria. The single-crystal elastic moduli are valuable for designing such optical components. In particular, the temperature derivatives of elastic moduli allow the dimensional changes due to heating under physical constraints, as well as acoustic excitation, to be determined. The single-crystal elastic moduli of yttria were measured by Brillouin spectroscopy up to 1200 C. The room-temperature values obtained were C(sub 11) = 223.6 + 0.6 GPa, C(sub 44) = 74.6 + 0.5 GPa, and C(sub 12) = 112.4 + 1.0 GPa. The resulting bulk and (Voigt-Reuss-Hill) shear moduli were K = 149.5 + 1.0 GPa and G(sub VRH) = 66.3 + 0.8 GPa, respectively. Linear least-squares regressions to the variation of bulk and shear moduli with temperature resulted in derivatives of dK/dT = -17 + 2 MPa/C and dG(sub VRH)/dT = -8 + 2 MPa/ C. Elastic anisotropy was found to remain essentially constant over the temperature range studied.

  7. Comparison of measurements and simulation results in 300 mm CZ silicon crystal growth

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A special thermal modeling tool, CrysVUn, which was developed by Crystal Growth Laboratory (CGL) of Fraunhofer Institute of Integrated Systems and Devices Technology in Erlangen of Germany, was used for numerical analysis of growth Interface situation. The heat transportation, argon flow and melt convection have been considered. Cauchy's first and second laws of motion have been the governing partial equations for stress calculation. The measurement results and simulation results were compared and the interface shape and thermal stress distribution during 300 mm Czochralski (CZ) silicon crystal growth with different growth rates were predicted.

  8. Comparative study of <111> and <100> crystals and capacitance measurements on Si strip detectors in CMS

    CERN Document Server

    Albergo, S; Azzi, P; Babucci, E; Bacchetta, N; Bader, A J; Bagliesi, G; Basti, A; Biggeri, U; Bilei, G M; Bisello, D; Boemi, D; Bosi, F; Borrello, L; Bozzi, C; Braibant, S; Breuker, Horst; Bruzzi, Mara; Buffini, A; Busoni, S; Candelori, A; Caner, A; Castaldi, R; Castro, A; Catacchini, E; Checcucci, B; Ciampolini, P; Civinini, C; Creanza, D; D'Alessandro, R; Da Rold, M; Demaria, N; De Palma, M; Dell'Orso, R; Marina, R D; Dutta, S; Eklund, C; Peisert, Anna; Feld, L; Fiore, L; Focardi, E; French, M; Freudenreich, Klaus; Fürtjes, A; Giassi, A; Giorgi, M A; Giraldo, A; Glessing, B; Gu, W H; Hall, G; Hammarström, R; Hebbeker, T; Hrubec, Josef; Huhtinen, M; Kaminski, A; Karimäki, V; Saint-Koenig, M; Krammer, Manfred; Lariccia, P; Lenzi, M; Loreti, M; Lübelsmeyer, K; Lustermann, W; Mättig, P; Maggi, G; Mannelli, M; Mantovani, G C; Marchioro, A; Mariotti, C; Martignon, G; McEvoy, B; Meschini, M; Messineo, A; Migliore, E; My, S; Paccagnella, A; Palla, Fabrizio; Pandoulas, D; Papi, A; Parrini, G; Passeri, D; Pieri, M; Piperov, S; Potenza, R; Raducci, V; Raffaelli, F; Raymond, M; Santocchia, A; Schmitt, B; Selvaggi, G; Servoli, L; Sguazzoni, G; Siedling, R; Silvestris, L; Skog, K; Starodumov, Andrei; Stavitski, I; Stefanini, G; Tempesta, P; Tonelli, G; Tricomi, A; Tuuva, T; Vannini, C; Verdini, P G; Viertel, Gert M; Xie, Z; Li Ya Hong; Watts, S; Wittmer, B

    1999-01-01

    For the construction of the silicon microstrip detectors for the tracker of the CMS experiment, two different substrate choices were investigated: A high-resistivity (6 k Omega cm) substrate with crystal orientation and a low-resistivity (2 k Omega cm) one with crystal orientation. The interstrip and backplane capacitances were measured before and after the exposure to radiation in a range of strip pitches from 60 mu m to 240 mu m and for values of the width-over-pitch ratio between 0.1 and 0.5. (3 refs).

  9. Electrical conductivity measurements on gel grown KDP crystals added with some ammonium compounds

    Indian Academy of Sciences (India)

    T H Freeda; C Mahadevan

    2000-08-01

    Pure and impurity added [with NH4Cl, NH4NO3, NH4H2PO4, (NH4)2CO3 and (NH4)2SO4] KDP single crystals were grown by the gel method using silica gels. Electrical conductivity measurements were carried out along both the unique axis and perpendicular directions at various temperatures ranging from 28 to 140°C by the conventional two-probe method. The present study shows that the conductivity in KDP crystals, for all the five dopants considered, increases with the increase in impurity concentration and temperature. Activation energies were also determined and reported.

  10. Systematic hardness measurements on single crystals and polycrystalline blanks of cesium halides

    Indian Academy of Sciences (India)

    D B Sirdeshmukh; P Geeta Krishna; K G Subhadra

    2002-06-01

    Vickers and knoop hardness measurements were carried out on CsBr and CsI single crystals. Polycrystalline blanks of CsCl, CsBr and CsI were prepared by melting and characterized by X-ray diffraction. Vickers hardness measurements were carried out on these blanks. The hardness values were correlated with the lattice constant and the Schottky defect formation energy.

  11. A BaF2 crystal array for high energy -ray measurements

    Indian Academy of Sciences (India)

    A Ray; S R Banerjee; P Das

    2001-07-01

    We shall discuss about the scientific motivation and construction of a 7 × 7 BaF2 crystal array at Variable Energy Cyclotron Centre, Calcutta. This detector would be used to measure high energy -ray photons from GDR decay and proton–neutron bremsstrahlung reactions at the present 88'' cyclotron and upcoming superconducting cyclotron at VECC, Calcutta. This detector can also be used to measure photons from quark–gluon plasma at the relativistic heavy ion collider (RHIC) in USA.

  12. Accurate measurement of the main refractive indices and thermo-optical coefficients of the calcite crystal

    Institute of Scientific and Technical Information of China (English)

    Shuang Zhao; Fuquan Wu; Haifeng Wang; Weigang Zhong; Xiuzhen Li; Hengjing Tang; Meng Shi; Hongyan Deng

    2007-01-01

    The main refractive indices of calcite crystal are measured by the means of auto-collimation, and the thermo-optical coefficients are calculated. The coefficient expression of Sellmeier equation is obtained by solving Sellmeier equation strictly and the refractive indices of different wavelengths are calculated, which accord with experimental esultsery well. The measured main refractive indices of calcite at 488-nm wavelength are identical with the values obtained by Sellmeier equation.

  13. Pixel size and pitch measurements of liquid crystal spatial light modulator by optical diffraction

    Indian Academy of Sciences (India)

    Ravinder Kumar Banyal; B Raghavendra Prasad

    2005-08-01

    We present a simple technique for the determination of pixel size and pitch of liquid crystal (LC) based spatial light modulator (SLM). The proposed method is based on optical diffraction from pixelated LC panel that has been modeled as a two-dimensional array of rectangular apertures. A novel yet simple, two-plane measurement technique is implemented to circumvent the difficulty in absolute distance measurement. Experimental results are presented for electrically addressed twisted nematic LC-SLM removed from the display projector.

  14. Polarized fluorescence measurements of orientational order in a uniaxial liquid crystal

    DEFF Research Database (Denmark)

    Chapoy, L. Lawrence; DuPré, Donald B.

    1979-01-01

    The second and fourth orientational order parameters and , have been measured throughout the liquid crystalline phase of p-methoxybenzylidene-p[prime]-n-butylaniline (MBBA) using small quantities of a fluorescent probe. Complications of rotational Brownian motion and the intramolecular transfer...... of excitation energy were considered in the analysis. The results are in agreement with previous Raman measurements on the doped liquid crystal. The Journal of Chemical Physics is copyrighted by The American Institute of Physics....

  15. Determination of resistance to salt crystallization on natural stone measured with ultrasonic wave

    DEFF Research Database (Denmark)

    Alm, D.; Brix, S.; Kjærgaard, H. Howe;

    2008-01-01

    The use of panels as facade cladding has increased substantially during the last few decades. However, during recent years reports of facade problems have increased dramatically. Facade cladding has, in some cases, suffered from problems with durability such as exfoliation, disintegration of macr...... porosity while Perlatino has 1.1 % in open porosity. By means of ultrasonic measurements it is possible to detect damage in stones exposed to salt crystallization cycles. The results show a tendency to less resistance of salt crystallization for more porous materials....... and after salt exposure. Four different stones are investigated: the limestone Bateig Azul, the sandstone Oberkirchener, the limestone Perlatino, and the limestone Travertine. The procedure for the salt crystallization test is EN 12370 standard “Natural stone test methods – Determination of resistance...

  16. Greatly improved small inductance measurement using quartz crystal parasitic capacitance compensation.

    Science.gov (United States)

    Matko, Vojko; Jezernik, Karel

    2010-01-01

    Generally, quartz crystal inductance frequency pulling in oscillators is very low and therefore is not often used in practice. The new method of improving frequency pullability uses inductance to compensate for quartz stray capacitances. To this end, a special AT fundamental quartz crystal working near the antiresonance frequency is selected. By modifying its equivalent circuit with load inductance and series tuning capacitance, the magnetic sensing of the circuit can be highly improved. The experimental results show that the new approach using the quartz crystal stray capacitance compensation method increases the frequency pulling range (from ≅2 kHz/μH to ≅600 kHz/μH) by ×300 depending on the type of oscillator, making possible the measurement of nano-magnetic changes.

  17. Offset-free Measurement of Dipolar Couplings in a Single Crystal and Determination of Molecular Orientation

    CERN Document Server

    Jayanthi, S

    2010-01-01

    Dipolar couplings are an important source of structure as they provide site specific dipolar splittings for aligned samples and hence are extensively used for the study of membrane proteins in lipid bilayers, liquid crystals and single crystals. Of the many Separated Local Field (SLF) techniques existing to avail this information for static oriented systems, PISEMA (Polarization Inversion Spin Exchange at Magic Angle) has found to have wide application due to its many favorable characteristics. However the pulse sequence suffers from its inherent sensitivity to proton resonance frequency offset. We have recently proposed a sequence named DAPT (Dipolar Assisted Polarization Transfer: S. Jayanthi et al. Chem. Phys. Lett. 439, 407, 2007.) for dipolar coupling measurement which is found to be insensitive to proton offsets over wide range. In this presentation, we report the first implementation of the sequence on rigid systems. Experiments were done on a single crystal of N-Acetyl DL-Valine (NAV). Dipolar couplin...

  18. Comparison of measured and computed phase functions of individual tropospheric ice crystals

    Science.gov (United States)

    Stegmann, Patrick G.; Tropea, Cameron; Järvinen, Emma; Schnaiter, Martin

    2016-07-01

    Airplanes passing the incuda (lat. anvils) regions of tropical cumulonimbi-clouds are at risk of suffering an engine power-loss event and engine damage due to ice ingestion (Mason et al., 2006 [1]). Research in this field relies on optical measurement methods to characterize ice crystals; however the design and implementation of such methods presently suffer from the lack of reliable and efficient means of predicting the light scattering from ice crystals. The nascent discipline of direct measurement of phase functions of ice crystals in conjunction with particle imaging and forward modelling through geometrical optics derivative- and Transition matrix-codes for the first time allow us to obtain a deeper understanding of the optical properties of real tropospheric ice crystals. In this manuscript, a sample phase function obtained via the Particle Habit Imaging and Polar Scattering (PHIPS) probe during a measurement campaign in flight over Brazil will be compared to three different light scattering codes. This includes a newly developed first order geometrical optics code taking into account the influence of the Gaussian beam illumination used in the PHIPS device, as well as the reference ray tracing code of Macke and the T-matrix code of Kahnert.

  19. Measurement of ultimate tensile strength and Young modulus in LYSO scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    Scalise, Lorenzo, E-mail: l.scalise@univpm.it [Dipartimento di Meccanica, Universita Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy); Rinaldi, Daniele [Dipartimento di Fisica e Ingegneria dei Materiali e del Territorio, Universita Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy); Istituto Nazionale di Fisica Nucleare, Section of Perugia (Italy); Davi, Fabrizio [Dipartimento di Architettura Costruzioni e Strutture, Universita Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy); Paone, Nicola [Dipartimento di Meccanica, Universita Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy)

    2011-10-21

    Scintillating crystals are employed in high energy physics, in medical imaging, diagnostic and security. Two mechanical properties of lutetium-yttrium oxyorthosilicate cerium-doped Lu{sub 2(1-x)}Y{sub 2x}SiO{sub 5}:Ce with x=0.1 (LYSO) crystals have been measured: the ultimate tensile stress ({sigma}{sub UTS}) and the Young elastic modulus (E). Measurements are made by means of a 4-points loading device and the experimental results account for an elastic-brittle stress-strain relation, which depends heavily on the specimen preparation and the material defects. {sigma}{sub UTS} along the [0 1 0] tensile direction ranges within 68.14 and 115.61 MPa, which, in the lowest case, is more than twice with respect to those measured for PbWO{sub 4} (PWO), exhibiting a marked difference between the annealed and the not-annealed samples. The mean elastic modulus (E), along the same direction, is E=1.80x10{sup 11} ({+-}2.15x10{sup 10}) N/m{sup 2}, with lower dispersion respect to UTS data. This type of analysis and study can be included into quality control procedures of crystals, based on samples taken out of production; such procedures can be established for industrial processing of crystals aimed to the high energy physics (calorimeters) and medical imaging (PET, etc.) applications.

  20. Measurement of integral diffraction coefficients of crystals on beamline 4B7of Beijing Synchrotron Radiation Facility

    Institute of Scientific and Technical Information of China (English)

    Yang Jia-Min; Hu Zhi-Min; Wei Min-Xi; Zhang Ji-Yan; Yi Rong-Qing; Gan Xin-Shi; Zhao Yang; Cui Ming-Qi; Zhu Tuo; Zhao Yi-Dong; Sun Li-Juan; Zheng Lei; Yan Fen

    2011-01-01

    Integral diffraction coefficients of the crystal are the essential data of a crystal spectrometer which is extensively used to measure quantitative x-ray spectra of high temperature plasmas in kilo-electron-volt region. An experimental method has been developed to measure the integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility. The integral diffraction coefficients of several crystals including polyethylene terephthalate (PET), thallium acid phthalate (TIAP) and rubidium acid phthalate (RAP) crystals have been measured in the x-ray energy range 2100-5600 eV and compared with the calculations of the 'Darwin Prins' and the 'Mosaic' models. It is shown that the integral diffraction coefficients of these crystals are between the calculations of the 'Darwin Prins' and the 'Mosaic' models, but more close to the 'Darwin Prins' model calculations.

  1. Controlling and measuring quantum transport of heat in trapped-ion crystals.

    Science.gov (United States)

    Bermudez, A; Bruderer, M; Plenio, M B

    2013-07-26

    Measuring heat flow through nanoscale devices poses formidable practical difficulties as there is no "ampere meter" for heat. We propose to overcome this problem in a chain of trapped ions, where laser cooling the chain edges to different temperatures induces a heat current of local vibrations (vibrons). We show how to efficiently control and measure this current, including fluctuations, by coupling vibrons to internal ion states. This demonstrates that ion crystals provide an ideal platform for studying quantum transport, e.g., through thermal analogues of quantum wires and quantum dots. Notably, ion crystals may give access to measurements of the elusive bosonic fluctuations in heat currents and the onset of Fourier's law. Our results are strongly supported by numerical simulations for a realistic implementation with specific ions and system parameters.

  2. Gallium surface diffusion on GaAs (001) surfaces measured by crystallization dynamics of Ga droplets

    Energy Technology Data Exchange (ETDEWEB)

    Bietti, Sergio, E-mail: sergio.bietti@mater.unimib.it; Somaschini, Claudio; Esposito, Luca; Sanguinetti, Stefano [L–NESS and Dipartimento di Scienza dei Materiali, Università di Milano Bicocca, Via Cozzi 55, I–20125 Milano (Italy); Fedorov, Alexey [L–NESS and CNR–IFN, via Anzani 42, I-22100 Como (Italy)

    2014-09-21

    We present accurate measurements of Ga cation surface diffusion on GaAs surfaces. The measurement method relies on atomic force microscopy measurement of the morphology of nano–disks that evolve, under group V supply, from nanoscale group III droplets, earlier deposited on the substrate surface. The dependence of the radius of such nano-droplets on crystallization conditions gives direct access to Ga diffusion length. We found an activation energy for Ga on GaAs(001) diffusion E{sub A}=1.31±0.15 eV, a diffusivity prefactor of D₀=0.53(×2.1±1) cm² s⁻¹ that we compare with the values present in literature. The obtained results permit to better understand the fundamental physics governing the motion of group III ad–atoms on III–V crystal surfaces and the fabrication of designable nanostructures.

  3. Effects of Blowing Ratio Measured by Liquid Crystal on Heat Transfer Characteristics of Trailing Edge Cutback

    Institute of Scientific and Technical Information of China (English)

    Yuan Hepeng; Zhu Huiren; Kong Manzhao

    2008-01-01

    This article deals with the effects of a blowing ratio measured with narrowbend liquid crystal in transonic experiments on the heat transfer characteristics of trailing edge cutback. The experimental results are compared end contrasted in terms of available data for tra-ditional experiments with thermocouples. It is concluded that the blowing ratio exerts rather significant effects on film cooling effec-tiveness distribution of the rib center line. As the blowing ratio decreases, similar to the cooling effectiveness distribution curve of the slot center line, that of the rib center line makes a clockwise rotation about the end. When the blowing ratio increases, the regular film cooling effectiveness curve of the surface becomes rather smooth. On the whole measuring surface, the most intensive heat transfer oc-curs at the extended borderline of the slot end the rib, neither at the rib center line nor at the slot center line. The experimental results of cooling effectiveness measured with thermocouples are lower than those with liquid crystal. In addition, the transient experiments using narrowband liquid crystal can eliminate the higher errors of Nusselt numbers in measurements with thermocouples at the slot outlet.

  4. Direct measurements of conventional and anisotropic magnetocaloric effect in binary RAl2 single crystals

    Science.gov (United States)

    Monteiro, J. C. B.; Gandra, F. G.

    2017-06-01

    We report on specific heat and magnetocaloric effect (MCE) measurements in single crystals of HoAl2, DyAl2, and TbAl2 measured by a heat flux technique using Peltier devices. Those compounds order ferromagnetically at 31 K, 61 K, and 106 K respectively, and present a spin reorientation transition (SRT) below TC. We study the dependence of the SRT with magnetic field and temperature by means of specific heat measurements performed in single crystals oriented at the [" separators="| 100 ], [" separators="| 110 ], and [" separators="| 111 ] directions with the aid of calculations using a simple model. We obtained the conventional MCE for HoAl2 and TbAl2 and also the anisotropic version of the effect obtained indirectly from the specific heat for TbAl2 and DyAl2. We also present the results for a direct determination of the anisotropic MCE for DyAl2 by measuring the heat flux generated by a rotation of the single crystal under constant field.

  5. Effects of ice crystals on the FSSP measurements in mixed phase clouds

    Directory of Open Access Journals (Sweden)

    G. Febvre

    2012-03-01

    Full Text Available In this paper, we show that in mixed phase clouds FSSP-100 measurements may be contaminated by ice crystals, inducing wrong interpretation of particle size and subsequent bulk parameters. This contamination is generally revealed by a bimodal feature of the particle size distribution; in other words, in mixed phase clouds bimodal features could be an indication of the presence of ice particles. The combined measurements of the FSSP-100 and the Polar Nephelometer give a coherent description of the effect of the ice crystals on the FSSP-100 response. The FSSP-100 particle size distributions are characterized by a bimodal shape with a second mode peaked between 25 and 35 μm related to ice crystals. This feature is observed with the FSSP-100 at airspeed up to 200 m s−1 and with the FSSP-300 series. In order to assess the size calibration for clouds of ice crystals the response of the FSSP-100 probe has been numerically simulated using a light scattering model of randomly oriented hexagonal ice particles and assuming both smooth and rough crystal surfaces. The results suggest that the second mode measured between 25 μm and 35 μm, does not necessarily represent true size responses but likely corresponds to bigger aspherical ice particles. According to simulation results, the sizing understatement would be neglected in the rough case but would be major with the smooth case. Qualitatively, the Polar Nephelometer phase function suggests that the rough case is the more suitable to describe real crystals. Quantitatively, however, it is difficult to conclude. Previous cloud in situ measurements suggest that the FSSP-100 secondary mode, peaked in the range 25–35 μm, is likely to be due to the shattering of large ice crystals on the probe tips. This finding is supported by the rather good relationship between the concentration of particles larger than 20 μm (hypothesized to be ice shattered-fragments measured by the FSSP and the

  6. Three-dimensional distortion measurements by section rocking curve imaging: Application to ice crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kluender, Rafael T.; Baruchel, Jose [ESRF, 6 rue Jules Horowitz, BP 220, 38043 Grenoble (France); Philip, Armelle; Meyssonnier, Jacques [LGGE, UJF-CNRS UMR 5183, 54 rue Moliere, 38402 St. Martin d' Heres (France)

    2011-11-15

    We present a new method to measure distortions in the entire crystal volume, down to a scale of 50 x 50 x 50 {mu}m{sup 3} elementary volume. The method combines rocking curve imaging (RCI), section- and pinhole diffraction topography. As results we obtain three-dimensional (3D) maps providing the integrated diffracted beam intensity and the fields of angular lattice misorientation. Angular misorientations down to 10{sup -5}-10{sup -6} have been measured. In this paper the method is applied to one of the grains of a three-grained ice polycrystal (tri-crystal). (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Improved measurement results for the Avogadro constant using a 28Si-enriched crystal

    CERN Document Server

    Azuma, Y; Bartl, G; Bettin, H; Borys, M; Busch, I; Cibik, L; D'Agostino, G; Fujii, K; Fujimoto, H; Hioki, A; Krumrey, M; Kuetgens, U; Kuramoto, N; Mana, G; Massa, E; Meeß, R; Mizushima, S; Narukawa, T; Nicolaus, A; Pramann, A; Rabb, S A; Rienitz, O; Sasso, C; Stock, M; Vocke, R D; Waseda, A; Wundrack, S; Zakel, S

    2015-01-01

    New results are reported from an ongoing international research effort to accurately determine the Avogadro constant by counting the atoms in an isotopically enriched silicon crystal. The surfaces of two 28Si-enriched spheres were decontaminated and reworked in order to produce an outer surface without metal contamination and improved sphericity. New measurements were then made on these two reconditioned spheres using improved methods and apparatuses. When combined with other recently refined parameter measurements, the Avogadro constant derived from these new results has a value of $N_A = 6.022 140 76(12) \\times 10^{23}$ mol$^{-1}$. The X-ray crystal density method has thus achieved the target relative standard uncertainty of $2.0 \\times 10^{-8}$ necessary for the realization of the definition of the new kilogram.

  8. Detecting, visualizing, and measuring gold nanoparticle chirality using helical pitch measurements in nematic liquid crystal phases.

    Science.gov (United States)

    Sharma, Anshul; Mori, Taizo; Lee, Huey-Charn; Worden, Matthew; Bidwell, Eric; Hegmann, Torsten

    2014-12-23

    Chirality at the nanoscale, or more precisely, the chirality or chiroptical effects of chiral ligand-capped metal nanoparticles (NPs) is an intriguing and rapidly evolving field in nanomaterial research with promising applications in catalysis, metamaterials, and chiral sensing. The aim of this work was to seek out a system that not only allows the detection and understanding of NP chirality but also permits visualization of the extent of chirality transfer to a surrounding medium. The nematic liquid crystal phase is an ideal candidate, displaying characteristic defect texture changes upon doping with chiral additives. To test this, we synthesized chiral cholesterol-capped gold NPs and prepared well-dispersed mixtures in two nematic liquid crystal hosts. Induced circular dichroism spectropolarimetry and polarized light optical microscopy revealed that all three gold NPs induce chiral nematic phases, and that those synthesized in the presence of a chiral bias (disulfide) are more powerful chiral inducers than those where the NP was formed in the absence of a chiral bias (prepared by conjugation of a chiral silane to preformed NPs). Helical pitch data here visually show a clear dependence on the NP size and the number of chiral ligands bound to the NP surface, thereby supporting earlier experimental and theoretical data that smaller metal NPs made in the presence of a chiral bias are stronger chiral inducers.

  9. Measurements of thermal conductivity and thermal diffusivity of hen egg-white lysozyme crystals using a short hot wire method

    Science.gov (United States)

    Fujiwara, Seiji; Maki, Syou; Tanaka, Seiichi; Maekawa, Ryunosuke; Masuda, Tomoki; Hagiwara, Masayuki

    2017-07-01

    Thermal conductivity and thermal diffusivity of hen egg-white lysozyme (HEWL) crystals were examined by using the transient short hot wire method. This method is based on the conventional hot wire method, but improved by using a wire that is much shorter than conventional ones. The magneto-Archimedes levitation technique was utilized to attach the HEWL crystals onto the wire. Owing to the upward magnetic force, the HEWL crystals were deposited at the air-liquid interface of the protein buffer solution where the short hot wire was preliminarily fixed. In situ observation clarified that the wire was completely buried into the HEWL crystals. By means of these techniques, the measurement of thermal conductivity and thermal diffusivity of HEWL crystals was realized for the first time. Gadolinium chloride (a paramagnetic subject) was used as a precipitant agent of crystallization. Crystal growth was carried out over 20 h at 17.2 °C. The applied magnetic field was 4 T. Measurements were conducted during the crystal growth at two different times. The thermal conductivity and diffusivity of the HEWL crystals were determined to be 0.410 W/(m.K) and 3.77×10-8 m2/s at 14 h after, and 0.438 W/(m.K) and 5.18×10-8 m2/s at 20 h after, respectively. We emphasize that this method is versatile and applicable for other protein crystals.

  10. On Mass Loading and Dissipation Measured with Acoustic Wave Sensors: A Review

    Directory of Open Access Journals (Sweden)

    Marina V. Voinova

    2009-01-01

    Full Text Available We summarize current trends in the analysis of physical properties (surface mass density, viscosity, elasticity, friction, and charge of various thin films measured with a solid-state sensor oscillating in a gaseous or liquid environment. We cover three different types of mechanically oscillating sensors: the quartz crystal microbalance with dissipation (QCM-D monitoring, surface acoustic wave (SAW, resonators and magnetoelastic sensors (MESs. The fourth class of novel acoustic wave (AW mass sensors, namely thin-film bulk acoustic resonators (TFBARs on vibrating membranes is discussed in brief. The paper contains a survey of theoretical results and practical applications of the sensors and includes a comprehensive bibliography.

  11. Properties of small cirrus ice crystals from commercial aircraft measurements and implications for flight operations

    Directory of Open Access Journals (Sweden)

    Karl Beswick

    2015-10-01

    Full Text Available Measurements of cloud ice crystal size distributions have been made by a backscatter cloud probe (BCP mounted on five commercial airliners flying international routes that cross five continents. Bulk cloud parameters were also derived from the size distributions. As of 31 December 2014, a total of 4399 flights had accumulated data from 665 hours in more than 19 000 cirrus clouds larger than 5 km in length. The BCP measures the equivalent optical diameter (EOD of individual crystals in the 5–90 µm range from which size distributions are derived and recorded every 4 seconds. The cirrus cloud property database, an ongoing development stemming from these measurements, registers the total crystal number and mass concentration, effective and median volume diameters and extinction coefficients derived from the size distribution. This information is accompanied by the environmental temperature, pressure, aircraft position, date and time of each sample. The seasonal variations of the cirrus cloud properties measured from 2012 to 2014 are determined for six geographic regions in the tropics and extratropics. Number concentrations range from a few per litre for thin cirrus to several hundreds of thousands for heavy cirrus. Temperatures range from 205 to 250 K and effective radii from 12 to 20 µm. A comparison of the regional and seasonal number and mass size distributions, and the bulk microphysical properties derived from them, demonstrates that cirrus properties cannot be easily parameterised by temperature or by latitude. The seasonal changes in the size distributions from the extratropical Atlantic and Eurasian air routes are distinctly different, showing shifts from mono-modal to bi-modal spectra out of phase with one another. This phase difference may be linked to the timing of deep convection and cold fronts that lead to the cirrus formation. Likewise, the size spectra of cirrus over the tropical Atlantic and Eastern Brazil differ from each

  12. D.C. electrical conductivity measurements on ADP single crystals added with simple organic compounds

    Indian Academy of Sciences (India)

    A Anne Assencia; C Mahadevan

    2005-08-01

    Pure and impurity added (with urea and thiourea) ADP single crystals were grown by the free evaporation method. D.C. electrical conductivity measurements were carried out along both the unique axis and perpendicular directions at various temperatures ranging from 40–150°C by the conventional two-probe method. Activation energies were also determined. The present study indicates that the conductivity increases with the increase in impurity concentration and temperature.

  13. Development of an X-ray fluorescence holographic measurement system for protein crystals

    Science.gov (United States)

    Sato-Tomita, Ayana; Shibayama, Naoya; Happo, Naohisa; Kimura, Koji; Okabe, Takahiro; Matsushita, Tomohiro; Park, Sam-Yong; Sasaki, Yuji C.; Hayashi, Kouichi

    2016-06-01

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α2β2 tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm3) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  14. Development of an X-ray fluorescence holographic measurement system for protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sato-Tomita, Ayana, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Shibayama, Naoya, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Okabe, Takahiro [Division of Biophysics, Department of Physiology, Jichi Medical University, Yakushiji, Shimotsuke 329-0498 (Japan); Happo, Naohisa [Department of Computer and Network Engineering, Graduate School of Information Sciences, Hiroshima City University, Asa-Minami-Ku, Hiroshima 731-3194 (Japan); Kimura, Koji [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Matsushita, Tomohiro [Japan Synchrotron Radiation Research Institute (JASRI), SPring-8, Sayo, Hyogo 679-5198 (Japan); Park, Sam-Yong [Drug Design Laboratory, Department of Medical Life Science, Yokohama City University, Suehiro, Tsurumi, Yokohama 230-0045 (Japan); Sasaki, Yuji C. [Department of Advanced Material Science, Graduate School of Frontier Science, The University of Tokyo, Kashiwanoha, Kashiwa 277-8561 (Japan); Hayashi, Kouichi, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Frontier Research Institute for Materials Science, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan)

    2016-06-15

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α{sub 2}β{sub 2} tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm{sup 3}) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  15. Effect of polyglycerol esters additive on palm oil crystallization using focused beam reflectance measurement and differential scanning calorimetry.

    Science.gov (United States)

    Saw, M H; Hishamuddin, E; Chong, C L; Yeoh, C B; Lim, W H

    2017-01-01

    The effect of 0.1-0.7% (w/w) of polyglycerol esters (PGEmix-8) on palm oil crystallization was studied using focused beam reflectance measurement (FBRM) to analyze the in-line changes of crystal size distribution during the crystallization. FBRM results show that 0.1-0.5% (w/w) of PGEmix-8 did not significantly affect nucleation but slightly retarded crystal growth. The use of 0.7% (w/w) additive showed greater heterogeneous nucleation compared to those with lower dosages of additive. Crystal growth was also greatly reduced when using 0.7% (w/w) dosage. The morphological study indicated that the palm oil crystals were smaller and more even in size than when more additive was added. Isothermal crystallization studies using differential scanning calorimetry (DSC) showed increased inhibitory effects on palm oil crystal growth with increasing concentration of PGEmix-8. These results imply that PGEmix-8 is a nucleation enhancing and crystal growth retarding additive in palm oil crystallization at 0.7% (w/w) dosage. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Improving the precision of Hall effect measurements using a single-crystal copper probe.

    Science.gov (United States)

    Cha, Su-Young; Shin, Jong Moon; Kim, Su Jae; Park, Sang Eon; Cho, Chae Ryong; Cho, Yong Chan; Jeong, Se-Young

    2012-01-01

    The circuitry and components of a Hall measurement kit were replaced with single-crystal copper (SCC) wires and parts prepared by a novel wire fabrication process. This process preserved the grain-free structure of SCC grown by the Czochralski method. The new kit was used to determine, with greatly improved precision, the electrical coefficients such as carrier density and mobility, establish the reproducibility of the measured values, and define the semiconductor type. The observed reduction in electrical signal losses and distortion has been attributed to grain boundary elimination.

  17. Bovine serum albumin detection and quantitation based on capacitance measurements of liquid crystals

    Science.gov (United States)

    Lin, Chi-Hao; Lee, Mon-Juan; Lee, Wei

    2016-08-01

    Liquid crystal (LC)-based biosensing is generally limited by the lack of accurate quantitative strategies. This study exploits the unique electric capacitance properties of LCs to establish quantitative assay methods for bovine serum albumin (BSA) biomolecules. By measuring the voltage-dependent electric capacitance of LCs under an alternating-current field with increasing amplitude, positive correlations were derived between the BSA concentration and the electric capacitance parameters of LCs. This study demonstrates that quantitative analysis can be achieved in LC-based biosensing through electric capacitance measurements extensively employed in LCD research and development.

  18. An Exploration of the Metal Dependent Selectivity of a Metalloporphyrins Coated Quartz Microbalances Array

    Directory of Open Access Journals (Sweden)

    Alexandro Catini

    2016-10-01

    Full Text Available Several studies in the last two decades have demonstrated that metalloporphyrins coated quartz microbalances can be fruitfully used in many diverse applications, spanning from medical diagnosis to environmental control. This large versatility is due to the combination of the flexibility of metalloporphyrins molecular design with the independence of the quartz microbalance signal from the interaction mechanisms. The nature of the metal atom in the metalloporphyrins is often indicated as one of the most effective tools to design differently selective sensors. However, the properties of sensors are also strongly affected by the characteristics of the transducer. In this paper, the role of the metal atom is investigated studying the response, to various volatile compounds, of six quartz microbalance sensors that are based on the same porphyrin but with different metals. Results show that, since quartz microbalances (QMB transducers can sense all the interactions between porphyrin and volatile compounds, the metal ion does not completely determine the sensor behaviour. Rather, the sensors based on the same molecular ring but with different metal ions show a non-negligible common behaviour. However, even if limited, the different metals still confer peculiar properties to the sensors and might drive the sensor array identification of the pool of tested volatile compounds.

  19. An Exploration of the Metal Dependent Selectivity of a Metalloporphyrins Coated Quartz Microbalances Array

    Science.gov (United States)

    Catini, Alexandro; Kumar, Raj; Capuano, Rosamaria; Martinelli, Eugenio; Paolesse, Roberto; di Natale, Corrado

    2016-01-01

    Several studies in the last two decades have demonstrated that metalloporphyrins coated quartz microbalances can be fruitfully used in many diverse applications, spanning from medical diagnosis to environmental control. This large versatility is due to the combination of the flexibility of metalloporphyrins molecular design with the independence of the quartz microbalance signal from the interaction mechanisms. The nature of the metal atom in the metalloporphyrins is often indicated as one of the most effective tools to design differently selective sensors. However, the properties of sensors are also strongly affected by the characteristics of the transducer. In this paper, the role of the metal atom is investigated studying the response, to various volatile compounds, of six quartz microbalance sensors that are based on the same porphyrin but with different metals. Results show that, since quartz microbalances (QMB) transducers can sense all the interactions between porphyrin and volatile compounds, the metal ion does not completely determine the sensor behaviour. Rather, the sensors based on the same molecular ring but with different metal ions show a non negligible common behaviour. However, even if limited, the different metals still confer peculiar properties to the sensors and might drive the sensor array identification of the pool of tested volatile compounds. PMID:27782032

  20. Development of a high-pressure microbalance for hydrogen storage materials

    DEFF Research Database (Denmark)

    Vestbø, Andreas Peter; Jensen, Jens Oluf; Bjerrum, Niels

    2007-01-01

    Pressure-composition isotherms (PCI's) help to determine thermodynamic properties related to hydrogen uptake of materials. PCI's are normally obtained volumetrically with a Sieverts type apparatus or gravimetrically with a microbalance. A potential problem with the gravimetric technique is that t...

  1. Probing crystal packing of uniformly (13)C-enriched powder samples using homonuclear dipolar coupling measurements.

    Science.gov (United States)

    Mollica, Giulia; Dekhil, Myriam; Ziarelli, Fabio; Thureau, Pierre; Viel, Stéphane

    2015-02-01

    The relationship between the crystal packing of powder samples and long-range (13)C-(13)C homonuclear dipolar couplings is presented and illustrated for the case of uniformly (13)C-enriched L-alanine and L-histidine·HCl·H2O. Dipolar coupling measurement is based on the partial reintroduction of dipolar interactions by spinning the sample slightly off-magic-angle, while the coupling of interest for a given spin pair is isolated with a frequency-selective pulse. A cost function is used to correlate the so-derived dipolar couplings to trial crystal structures of the samples under study. This procedure allowed for the investigation of the l-alanine space group and L-histidine·HCl·H2O space group and unit-cell parameters.

  2. Measurement of refractive index of biaxial potassium titanyl phosphate crystal plate using reflection spectroscopic ellipsometry technique

    Indian Academy of Sciences (India)

    A K Chaudhary; A Molla; A Asfaw

    2009-10-01

    The paper reports the measurement of refractive indices and anisotropic absorption coefficients of biaxial potassium titanyl phosphate (KTP) crystal in the form of thin plate using reflection ellipsometry technique. This experiment is designed in the Graduate Optics Laboratory of the Addis Ababa University and He–Ne laser ( = 632.8 nm), diode laser ( = 670.0 nm) and temperature-tuned diode laser ( = 804.4 and 808.4 nm), respectively have been employed as source. The experimental data for , are fitted to the Marquardt–Levenberg theoretical model of curve fitting. The obtained experimental data of refractive indices are compared with different existing theoretical and experimental values of KTP crystals and found to be in good agreement with them.

  3. Measurement of the \\{220\\} lattice-plane spacing of a $^{28}$Si crystal

    CERN Document Server

    Massa, Enrico; Kuetgens, Ulrich; Ferroglio, Luca

    2010-01-01

    The spacing of the \\{220\\} lattice planes of a $^{28}$Si crystal was measured by combined x-ray and optical interferometry to a $3.5\\times 10^{-9}$ relative accuracy. The result is $d_{220}=(192014712.67 \\pm 0.67)$ am, at 20.0 $^\\circ$C and 0 Pa. This value is greater by $(1.9464 \\pm 0.0067)\\times 10^{-9} d_{220}$ than the spacing in natural Si, a difference which confirms quantum mechanics calculations. Subsequently, this crystal has been used to determine the Avogadro constant by counting the Si atoms, a key step towards a realization of the mass unit based on a conventional value of the Planck or the Avogadro constants.

  4. Measurements along the growth direction of PMN-PT crystals: dielectric, piezoelectric, and elastic properties.

    Science.gov (United States)

    Tian, Jian; Han, Pengdi; Payne, David A

    2007-09-01

    Property measurements are reported for Pb(Mg1/3Nb2/3)03-PbTiO3 (PMN-PT) single crystals grown along (001) by a seeded-melt method. Chemical segregation occurs during crystal growth, leading to property changes along the growth direction. Variations in dielectric, piezoelectric, and elastic properties were evaluated for specimens selected from the crystals. Room-temperature data are correlated with Tc and composition that ranged from 27 to 32% PT, i.e., in the vicinity of the morphotropic phase boundary (MPB). While there was little change in the high electromechanical coupling factor k33 (0.87-0.92), both the piezoelectric charge coefficient d33 (1100-1800 pC/N) and the free dielectric constant K3 (4400-7000) were found to vary significantly with position. Increases in d33 and KT33 were relatively offsetting in that the ratio yielded a relatively stable piezoelectric voltage coefficient g33 (27-31 x 10(-3) Vm/N). Values are also reported for the elastic compliance (3.3-6.3 x 10(-11) m2/N) determined from resonance measurements. Enhancements in d33 and K(T)33 were associated with lattice softening (increasing sE33) as the composition approached the MPB. Details are reported for the piezoelectric, dielectric, and elastic properties as a function of growth direction, Tc, and composition. The results are useful for an understanding of properties in PMN-PT crystals and for the design of piezoelectric devices.

  5. A dibutyl phthalate sensor based on a nanofiber polyaniline coated quartz crystal monitor.

    Science.gov (United States)

    Wang, You; Ding, Pengfei; Hu, Ruifen; Zhang, Jianming; Ma, Xingfa; Luo, Zhiyuan; Li, Guang

    2013-03-18

    Dibutyl phthalate (DBP) is a commonly used plasticizer and additive to adhesives, printing inks and nail polishes. Because it has been found to be a powerful reproductive and developmental toxicant, a sensor to monitor DBP in some working spaces and the environment is required. In this work polyaniline nanofibers were deposited on the electrode of a quartz crystal oscillator to form a Quartz Crystal Microbalance gas sensor. The coated quartz crystal and a non-coated quartz crystal were mounted in a sealed chamber, and their frequency difference was monitored. When DBP vapor was injected into the chamber, gas adsorption decreased the frequency of the coated quartz crystal oscillator and thereby caused an increase in the frequency difference between the two crystals. The change of the frequency difference was recorded as the sensor response. The sensor was extremely sensitive to DBP and could be easily recovered by N2 purging. A low measurement limit of 20 ppb was achieved. The morphologies of the polyaniline films prepared by different approaches have been studied by SEM and BET. How the nanofiber-structure can improve the sensitivity and stability is discussed, while its selectivity and long-term stability were investigated.

  6. The origins of ice crystals measured in mixed phase clouds at High-Alpine site Jungfraujoch

    Directory of Open Access Journals (Sweden)

    G. Lloyd

    2015-07-01

    Full Text Available During the winter of 2013 and 2014 measurements of cloud microphysical properties over a five week period at the high Alpine site Jungfraujoch, Switzerland were carried out as part of the Cloud Aerosol Characterisation Experiments (CLACE and the Ice Nucleation Process Investigation and Quantification project (INUPIAQ Measurements of aerosol properties at a second, lower site, Schilthorn, Switzerland, were used as input for a primary ice nucleation scheme to predict ice nuclei concentrations at Jungfraujoch Frequent, rapid transitions in the ice and liquid properties of the clouds at Jungfraujoch were identified that led to large fluctuations in ice mass fractions over temporal scales of seconds to hours. During the measurement period we observed high concentrations of ice particles that exceeded 1000 L−1 at temperatures around −15 °C, verified by multiple instruments These concentrations could not be explained using the usual primary ice nucleation schemes, which predicted ice nucleus concentrations several orders of magnitude smaller than the peak ice crystal number concentrations. Secondary ice production through the Hallet–Mossop process as a possible explanation was ruled out, as the cloud was rarely within the active temperature range for this process It is shown that other mechanisms of secondary ice particle production cannot explain the highest ice particle concentrations. We describe 4 possible mechanisms that could lead to high cloud ice concentrations generated from the snow covered surfaces surrounding the measurement site. Of these we show that hoar frost crystals generated at the cloud enveloped snow surface could be the most important source of cloud ice concentrations Blowing snow was also observed to make significant contributions at higher wind speeds when ice crystal concentrations were −1.

  7. Detrital illite crystals identified from crystallite thickness measurements in siliciclastic sediments

    Science.gov (United States)

    Aldega, L.; Eberl, D.D.

    2005-01-01

    Illite crystals in siliciclastic sediments are heterogeneous assemblages of detrital material coming from various source rocks and, at paleotemperatures >70 ??C, of superimposed diagenetic modification in the parent sediment. We distinguished the relative proportions of 2M1 detrital illite and possible diagenetic 1Md + 1M illite by a combined analysis of crystal-size distribution and illite polytype quantification. We found that the proportions of 1Md + 1M and 2M1 illite could be determined from crystallite thickness measurements (BWA method, using the MudMaster program) by unmixing measured crystallite thickness distributions using theoretical and calculated log-normal and/or asymptotic distributions. The end-member components that we used to unmix the measured distributions were three asymptotic-shaped distributions (assumed to be the diagenetic component of the mixture, the 1Md + 1M polytypes) calculated using the Galoper program (Phase A was simulated using 500 crystals per cycle of nucleation and growth, Phase B = 333/cycle, and Phase C = 250/ cycle), and one theoretical log-normal distribution (Phase D, assumed to approximate the detrital 2M1 component of the mixture). In addition, quantitative polytype analysis was carried out using the RockJock software for comparison. The two techniques gave comparable results (r2 = 0.93), which indicates that the unmixing method permits one to calculate the proportion of illite polytypes and, therefore, the proportion of 2M1 detrital illite, from crystallite thickness measurements. The overall illite crystallite thicknesses in the samples were found to be a function of the relative proportions of thick 2M1 and thin 1Md + 1M illite. The percentage of illite layers in I-S mixed layers correlates with the mean crystallite thickness of the 1Md + 1M polytypes, indicating that these polytypes, rather than the 2M1 polytype, participate in I-S mixed layering.

  8. Measuring nonlinear stresses generated by defects in 3D colloidal crystals

    CERN Document Server

    Lin, Neil Y C; Schall, Peter; Sethna, James P; Cohen, Itai

    2016-01-01

    The mechanical, structural and functional properties of crystals are determined by their defects and the distribution of stresses surrounding these defects has broad implications for the understanding of transport phenomena. When the defect density rises to levels routinely found in real-world materials, transport is governed by local stresses that are predominantly nonlinear. Such stress fields however, cannot be measured using conventional bulk and local measurement techniques. Here, we report direct and spatially resolved experimental measurements of the nonlinear stresses surrounding colloidal crystalline defect cores, and show that the stresses at vacancy cores generate attractive interactions between them. We also directly visualize the softening of crystalline regions surrounding dislocation cores, and find that stress fluctuations in quiescent polycrystals are uniformly distributed rather than localized at grain boundaries, as is the case in strained atomic polycrystals. Nonlinear stress measurements ...

  9. A Sensor Fusion Algorithm for Filtering Pyrometer Measurement Noise in the Czochralski Crystallization Process

    Directory of Open Access Journals (Sweden)

    M. Komperød

    2011-01-01

    Full Text Available The Czochralski (CZ crystallization process is used to produce monocrystalline silicon for solar cell wafers and electronics. Tight temperature control of the molten silicon is most important for achieving high crystal quality. SINTEF Materials and Chemistry operates a CZ process. During one CZ batch, two pyrometers were used for temperature measurement. The silicon pyrometer measures the temperature of the molten silicon. This pyrometer is assumed to be accurate, but has much high-frequency measurement noise. The graphite pyrometer measures the temperature of a graphite material. This pyrometer has little measurement noise. There is quite a good correlation between the two pyrometer measurements. This paper presents a sensor fusion algorithm that merges the two pyrometer signals for producing a temperature estimate with little measurement noise, while having significantly less phase lag than traditional lowpass- filtering of the silicon pyrometer. The algorithm consists of two sub-algorithms: (i A dynamic model is used to estimate the silicon temperature based on the graphite pyrometer, and (ii a lowpass filter and a highpass filter designed as complementary filters. The complementary filters are used to lowpass-filter the silicon pyrometer, highpass-filter the dynamic model output, and merge these filtered signals. Hence, the lowpass filter attenuates noise from the silicon pyrometer, while the graphite pyrometer and the dynamic model estimate those frequency components of the silicon temperature that are lost when lowpass-filtering the silicon pyrometer. The algorithm works well within a limited temperature range. To handle a larger temperature range, more research must be done to understand the process' nonlinear dynamics, and build this into the dynamic model.

  10. Measurement of group-velocity dispersion of Bloch modes in photonic-crystal-fiber rocking filters.

    Science.gov (United States)

    Wong, G K L; Zang, L; Kang, M S; Russell, P St J

    2010-12-01

    We use low-coherence interferometry to measure the group-velocity dispersion (GVD) of the fast and slow Bloch modes of structural rocking filters, produced by twisting a highly birefringent photonic crystal fiber to and fro while scanning a focused CO(2) laser beam along it. The GVD curves in the vicinity of the resonant wavelength differ dramatically from those of the unperturbed fiber, suggesting that rocking filters could be used in the optimization of, e.g., four-wave mixing and supercontinuum generation. Excellent agreement is obtained between theory and experiment.

  11. Measurement of the neutron electric dipole moment via spin rotation in a non-centrosymmetric crystal

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, V.V. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Jentschel, M. [Institut Laue-Langevin, Grenoble (France); Kuznetsov, I.A.; Lapin, E.G. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Lelievre-Berna, E.; Nesvizhevsky, V.; Petoukhov, A. [Institut Laue-Langevin, Grenoble (France); Semenikhin, S.Yu. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Soldner, T., E-mail: soldner@ill.f [Institut Laue-Langevin, Grenoble (France); Voronin, V.V., E-mail: vvv@pnpi.spb.r [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation); Braginetz, Yu.P. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg (Russian Federation)

    2010-10-25

    We have measured the neutron electric dipole moment using spin rotation in a non-centrosymmetric crystal. Our result is d{sub n}=(2.5{+-}6.5{sup stat{+-}}5.5{sup syst}).10{sup -24}ecm. The dominating contribution to the systematic uncertainty is statistical in nature and will reduce with improved statistics. The statistical sensitivity can be increased to 2.10{sup -26}ecm in 100 days data taking with an improved setup. We state technical requirements for a systematic uncertainty at the same level.

  12. Measurement of the neutron electric dipole moment via spin rotation in a non-centrosymmetric crystal

    CERN Document Server

    Fedorov, V V; Kuznetsov, I A; Lapin, E G; Lelievre-Berna, E; Nesvizhevsky, V; Petoukhov, A; Semenikhin, S Yu; Soldner, T; Voronin, V V; Braginetz, Yu P

    2010-01-01

    We have measured the neutron electric dipole moment using spin rotation in a non-centrosymmetric crystal. Our result is d_n = (2.5 +- 6.5(stat) +- 5.5(syst)) 10^{-24} e cm. The dominating contribution to the systematic uncertainty is statistical in nature and will reduce with improved statistics. The statistical sensitivity can be increased to 2 10^{-26} e cm in 100 days data taking with an improved setup. We state technical requirements for a systematic uncertainty at the same level.

  13. Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams

    Science.gov (United States)

    Moignier, Cyril; Tromson, Dominique; de Marzi, Ludovic; Marsolat, Fanny; García Hernández, Juan Carlos; Agelou, Mathieu; Pomorski, Michal; Woo, Romuald; Bourbotte, Jean-Michel; Moignau, Fabien; Lazaro, Delphine; Mazal, Alejandro

    2017-07-01

    The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro. In particular, various diamond thicknesses were simulated to evaluate the influence of the active volume thickness (e AV) as well as the influence of the addition of a front silver resin (250 µm in thickness in front of the diamond crystal) on depth-dose curves. The simulations indicated that the diamond crystal alone, with a small e AV of just 5 µm, already affects the dose at Bragg peak position (Bragg peak dose) by more than 2% with respect to the Bragg peak dose deposited in water. The optimal design that resulted from the Monte Carlo simulations consists of a diamond crystal of 1 mm in width and 150 µm in thickness with the front silver resin, enclosed by a water-equivalent packaging. This design leads to a deviation between the Bragg peak dose from the full detector modeling and the Bragg peak dose deposited in water of less than 1.2%. Based on those optimizations, an SCDD-Pro prototype was built and evaluated in broad passive scattering proton beams. The experimental evaluation led to probed SCDD-Pro repeatability, dose rate dependence and linearity, that were better than 0.2%, 0.4% (in the 1.0-5.5 Gy min-1 range) and 0.4% (for dose higher than 0.05 Gy), respectively. The depth-dose curves in the 90-160 MeV energy range, measured with the SCDD-Pro without applying any correction, were in good agreement with those measured using a commercial IBA PPC05 plane-parallel ionization chamber, differing by less than 1.6%. The experimental results confirmed that this SCDD-Pro is suitable for measurements with standard electrometers and that the depth-dose curve perturbation is negligible, with no energy dependence and no significant dose rate

  14. A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal.

    Science.gov (United States)

    Haugh, M J; Jacoby, K D; Barrios, M A; Thorn, D; Emig, J A; Schneider, M B

    2016-11-01

    We present a technique for determining the X-ray spectral quality from each region of an elliptically curved PET(002) crystal. The investigative technique utilizes the shape of the crystal rocking curve which changes significantly as the radius of curvature changes. This unique quality information enables the spectroscopist to verify where in the spectral range that the spectrometer performance is satisfactory and where there are regions that would show spectral distortion. A collection of rocking curve measurements for elliptically curved PET(002) has been built up in our X-ray laboratory. The multi-lamellar model from the XOP software has been used as a guide and corrections were applied to the model based upon measurements. But, the measurement of RI at small radius of curvature shows an anomalous behavior; the multi-lamellar model fails to show this behavior. The effect of this anomalous RI behavior on an X-ray spectrometer calibration is calculated. It is compared to the multi-lamellar model calculation which is completely inadequate for predicting RI for this range of curvature and spectral energies.

  15. A fundamental measure density functional for fluid and crystal phases of the Asakura-Oosawa model

    Science.gov (United States)

    Mortazavifar, Mostafa; Oettel, Martin

    2016-06-01

    We investigate a density functional for the Asakura-Oosawa model of colloid-polymer mixtures, describing both fluid and crystal phases. It is derived by linearizing the two-component fundamental-measure hard sphere tensor functional in the second (polymer) component. We discuss the formulation of an effective density functional for colloids only. For small polymer-colloid size ratios the effective, polymer-induced potential between colloids is short-range attractive and of two-body form but we show that the effective density functional is not equivalent to standard mean-field approaches where attractions are taken into account by terms second order in the colloid density. We calculate numerically free energies and phase diagrams in good agreement with available simulations, furthermore we discuss the colloid and polymer distributions in the crystal and determine equilibrium vacancy concentrations. Numerical results reveal a fairly strong sensitivity to the specific type of underlying fundamental measure hard sphere functional which could aid further development of fundamental measure theory.

  16. A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal

    Science.gov (United States)

    Haugh, M. J.; Jacoby, K. D.; Barrios, M. A.; Thorn, D.; Emig, J. A.; Schneider, M. B.

    2016-11-01

    We present a technique for determining the X-ray spectral quality from each region of an elliptically curved PET(002) crystal. The investigative technique utilizes the shape of the crystal rocking curve which changes significantly as the radius of curvature changes. This unique quality information enables the spectroscopist to verify where in the spectral range that the spectrometer performance is satisfactory and where there are regions that would show spectral distortion. A collection of rocking curve measurements for elliptically curved PET(002) has been built up in our X-ray laboratory. The multi-lamellar model from the XOP software has been used as a guide and corrections were applied to the model based upon measurements. But, the measurement of RI at small radius of curvature shows an anomalous behavior; the multi-lamellar model fails to show this behavior. The effect of this anomalous RI behavior on an X-ray spectrometer calibration is calculated. It is compared to the multi-lamellar model calculation which is completely inadequate for predicting RI for this range of curvature and spectral energies.

  17. Measuring the Th-229 nuclear isomer transition with U-233 doped crystals

    CERN Document Server

    Stellmer, Simon; Kazakov, Georgy; Sterba, Johannes; Schumm, Thorsten

    2015-01-01

    We propose a simple approach to measure the energy of the few-eV isomeric state in Th-229. To this end, U-229 nuclei are doped into VUV-transparent crystals, where they undergo alpha decay into Th-229, and, with a probability of 2%, populate the isomeric state. These Th-229m nuclei may decay into the nuclear ground state under emission of the sought-after VUV gamma, whose wavelength can be determined with a spectrometer. Based on measurements of the optical transmission of U:CaF2 crystals in the VUV range, we expect a signal at least 2 orders of magnitude larger compared to current schemes using surface-implantation of recoil nuclei. The signal background is dominated by Cherenkov radiation induced by beta decays of the thorium decay chain. We estimate that, even if the isomer undergoes radiative de-excitation with a probability of only 0.1%, the VUV gamma can be detected within a reasonable measurement time.

  18. Reflectance measurement of two-dimensional photonic crystal nanocavities with embedded quantum dots

    CERN Document Server

    Stumpf, Wolfgang C; Kojima, Takanori; Fujita, Masayuki; Tanaka, Yoshinori; Noda, Susumu

    2010-01-01

    The spectra of two-dimensional photonic crystal slab nanocavities with embedded InAs quantum dots are measured by photoluminescence and reflectance. In comparing the spectra taken by these two different methods, consistency with the nanocavities' resonant wavelengths is found. Furthermore, it is shown that the reflectance method can measure both active and passive cavities. Q-factors of nanocavities, whose resonant wavelengths range from 1280 to 1620 nm, are measured by the reflectance method in cross polarization. Experimentally, Q-factors decrease for longer wavelengths and the intensity, reflected by the nanocavities on resonance, becomes minimal around 1360 nm. The trend of the Q-factors is explained by the change of the slab thickness relative to the resonant wavelength, showing a good agreement between theory and experiment. The trend of reflected intensity by the nanocavities on resonance can be understood as effects that originate from the PC slab and the underlying air cladding thickness. In addition...

  19. Sidewall roughness measurement inside photonic crystal holes by atomic force microscopy

    Science.gov (United States)

    Strasser, P.; Robin, F.; Carlström, C. F.; Wüest, R.; Kappeler, R.; Jäckel, H.

    2007-10-01

    We present a measurement technique to quantify sidewall roughness inside planar photonic crystal (PhC) holes. Atomic force microscopy is used to scan hole cross-section profiles. By fitting a circle onto each scan line and subtracting this circle from the measurement data, a quantitative value for the deviation from the ideal cylindrical hole shape is extracted. We investigate the sidewall roughness of InP-based PhC holes depending on the nitrogen content of the semiconductor etching plasma. The existence of a trade-off between hole undercut and surface roughness by optimizing the flux of nitrogen during the plasma etching of the PhC holes is confirmed. We further quantify with this technique the influence of the direct-writing of octagons instead of circles by electron-beam lithography on the measured roughness.

  20. Single-crystal Sapphire Based Optical Polarimetric Sensor for High Temperature Measurement

    Directory of Open Access Journals (Sweden)

    Anbo Wang

    2006-08-01

    Full Text Available Optical sensors have been investigated and widely deployed in industrial andscientific measurement and control processes, mainly due to their accuracy, high sensitivityand immunity to electromagnetic interference and other unique characteristics. They areespecially suited for harsh environments applications, where no commercial electricalsensors are available for long-term stable operations. This paper reports a novel contactoptical high temperature sensor targeting at harsh environments. Utilizing birefringentsingle crystal sapphire as the sensing element and white light interferometric signalprocessing techniques, an optical birefringence based temperature sensor was developed.With a simple mechanically structured sensing probe, and an optical spectrum-codedinterferometric signal processor, it has been tested to measure temperature up to 1600 °Cwith high accuracy, high resolution, and long-term measurement stability.

  1. Chemically Selective Coated Quartz Crystal Microbalance (QCM) Array for Detection of Volatile Organic Chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Bohuszewicz, T.V.; Frye-Mason, G.C.; Martin, S.J.; Osbourn, G.C. Bartholomew, J.W.; Schneider, T.W.; Spates, J.J.

    1998-11-04

    Liquid flow cells have been fabricated to prepare an array of QCMS operating simultaneously for detection and identification of VOCS in water. TWO signals, a tlequency response and a damping voltage response, were obtained per resonator. A blank QCM was used as a reference to account for changes in liquid density and viscosity. Nine different polymer coatings applied using a spin coat technique have been examined for VOC response under liquid flow conditions. A matrix of three classes of VOCS were examined for each coating with four chemicals in each class. The three classes of VOCS are polar, nonpolar and chlorinated. A pattern recognition technique, called visually empirical region of influence (VERI), was used to cluster the responses in n-dimensional space. Chemicals within a class varying by only one methyl group (e.g., toluene and xylene) are easily discriminated using only two different coatings with three different QCM responses. All chemicak were easily separated and detected with a total of 5 films and 6 responses with >99% accuracy.

  2. Application of an Electrochemical Quartz Crystal Microbalance to the study of electrocatalytic films

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, J.S. Jr.

    1993-09-01

    The EQCM was used to study the deposition and composition of electrodeposited pure PbO{sub 2} and Bi-doped PbO{sub 2} active toward anodic oxygen-transfer reactions. Within the doped films, Bi is incorporated as Bi{sup +5} in the form of BiO{sub 2}A, where A is ClO{sub 4}{sup {minus}} or NO{sub 3}{sup {minus}}. For deposition of these 2 materials, changes in hydration between the Au oxide and the depositing film resulted in higher mass-to-charge ratios. XRD and XPS were used to study the films; the rutile structure of PbO{sub 2} is retained even with the Bi doping. The EQCM was also used to study the formation and dissolution of Au oxide and preoxide structures formed on the Au substrate electrodes in acidic media. The preoxide structures were AuOH and increased the surface mass. For the formation of stable Au films on quartz wafers, Ti interlayers between Au and quartz was found to be very effective.

  3. Capacitive Behavior in Conducting Polymers: AC Impedance and Quartz Crystal Microbalance Studies

    Science.gov (United States)

    1989-06-15

    Extended Abstracts, 175th National Meeting of the Electrochemical Society , Los Angeles, California, 1989 Corrosion Research Center Department of Chemical...114. DATE OF REPORT (Vear,Montha) 15PAGE COUNT Technical I Rom 7/88 TO 619I 89/06/15I 16. SUPPLEMENTARY NOTATION 175th Meeting of the Electrochemical ... Society , Extended Abstracts, May 1989 17 COSATI CODES IS. SUBJECT TERMS (Continue in reverie if necessary and identify by block number) FIELD GROUP

  4. Hydrolysis of model cellulose films by cellulosomes: Extension of quartz crystal microbalance techniques to multienzymatic complexes

    Science.gov (United States)

    Clostridium thermocellum, a well-studied cellulolytic bacterium, produces highly active cellulases in the form of cellulosomes. The ability of the cellulose binding module within the cellulosome to adhere C. thermocellum cells to the cellulosic substrate is considered to contribute to its high cellu...

  5. The Laser Ablation of Gold Films at the Electrode Surface of a Quartz Crystal Microbalance

    Science.gov (United States)

    1993-05-01

    to the QCM was controlled via a manual shutter. The laser beam was focussed onto the electrode surface of the QCM with a 150 mm f.l. lens. Fluence...A. Cross, H, Dallaporta, S. Lazare, H. Hiraoka, N. Merk and W. Marine, Appl. Surf Sci. 54 (1992) 278. 12. S. Lazare and V. Granier, J. App/. Phys. 63

  6. Chemically selective coated quartz-crystal-microbalance (QCM) array for detection of volatile organic chemicals

    Science.gov (United States)

    Schneider, Thomas W.; Frye-Mason, Gregory C.; Martin, Stephen J.; Spates, James J.; Bohuszewicz, Teresa V.; Osbourn, Gordon C.; Bartholomew, John W.

    1998-12-01

    Liquid flow cells have been fabricated to prepare an array of QCMs operating simultaneously for detection and identification of VOCs in water. Two signals, a frequency response and a damping voltage response, were obtained per resonator. A blank QCM was used as a reference to account for changes in liquid density and viscosity. Nine different polymer coatings applied using a spin coat technique have been examined for VOC response under liquid flow conditions. A matrix of three classes of VOCs were examined for each coating with four chemicals in each class. The three classes of VOCs are polar, nonpolar and chlorinated. A pattern recognition technique, called visually empirical region of influence, was used to cluster the responses in n- dimensional space. Chemicals within a class varying by only one methyl group (e.g., toluene and xylene) are easily discriminated using only two different coatings with three different QCM responses. All chemicals were easily separated and detected with a total of 5 films and 6 responses with >99% accuracy.

  7. Exploring silver ionic liquids for reaction-based gas sensing on a quartz crystal microbalance.

    Science.gov (United States)

    Li, Hsin-Yi; Hsu, Tzu-Hsuan; Chen, Chien-Yuan; Tseng, Ming-Chung; Chu, Yen-Ho

    2015-09-21

    Reaction-based, sensitive sensing of aldehyde and ketone gases in real time was effectively achieved on QCM chips thin-coated with silver ionic liquids and , respectively. The method platform developed in this work involves straightforward synthesis of functional silver ionic liquids in water, and is label-free and highly chemoselective with superior gas reactivity for and and, most significantly, totally insensitive to moisture.

  8. Quartz Crystal Microbalance Studies Of Dimethyl Methylphosphonate Sorption Into Trisilanolphenyl-Poss Films

    Science.gov (United States)

    2006-11-06

    VX. GB and GD dissolve in water and, at pH values PO OH F P O F O C H H H P O F O C H H H + Sarin (GB) Methylphosphono- fluoridic acid Propylene 5...quantitatively determined the amount of DMMP adsorbed onto an alumina-supported iron and cerium oxide surface using FTIR.18,19 At 25 °C, the alumina...LB-film. This value is actually larger than the degradation capacity of alumina-supported iron and cerium oxide surfaces, reported to be 510 µmol of

  9. Flat Crystal x-ray Spectrometer for Quantitative Spectral Measurement in the 2-5 keV Region

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yang; ZHANG Ji-Yan; YANG Jia-Min; WEI Min-Xi; DENG Bo; ZHU Tuo; HU Zhi-Min; XIONG Gang; SHANG Wan-Li; KUANG Long-Yu; YANG Guo-Hong

    2011-01-01

    @@ A technique of fiat crystal x-ray spectrometer for quantitative spectral measurement is described.For the flat crystal spectrograph geometry, the quantitative reduction of relating the CCD counts back to the photon flux from the x-ray source is established.The absolute calibrations of the integral diffraction coefficients of the crystal and the CCD sensitivity make it possible to measure absolute photons flux within the energy range of 2000-5000 eV.The uncertainty analysis of the calibrations is carried out to obtain the energy resolved uncertainties of crystal and CCD.Thus, the experimentai spectra with spectral resolved intensity uncertainties are available.Then, a performing experiment of laser-produced Ti plasma is carried out and the absolute x-ray spectra with intensity uncertainty less than 8.5% are obtained.The technique is promising for absolute spectral measurement of high temperature plasmas in a kilo-electron-volt region.

  10. Curved crystal spectrometer for the measurement of X-ray lines from laser-produced plasmas

    Institute of Scientific and Technical Information of China (English)

    SHI Jun; XIAO Sha-li; WANG Hong-jian; TANG Chang-huan; LIU Shen-ye

    2008-01-01

    In order to diagnose the laser-produced plasmas, a focusing curved crystal spectrometer has been developed for measuring the X-ray lines radiated from a laser-produced plasmas. The design is based on the fact that the ray emitted from a source located at one focus of an ellipse will converge on the other focus by the reflection of the elliptical surface. The focal length and the eccentricity of the ellipse are 1350 mm and 0.9586, respectively. The spectrometer can be used to measure the X-ray lines in the wavelength range of 0.2-0.37 nm, and a LiF crystal (200) (2d = 0.4027 nm) is used as dispersive element covering Bragg angle from 30° to 67.5°. The spectrometer was tested on Shenguang-Ⅱ which can deliver laser energy of 60-80 J/pulse and the laser wavelength is 0.35 μm. Photographs of spectra including the 1s2p 1p1-1s2 1S0 resonance line(w),the 1s2p 3P2-1s2 1S0 magnetic quadrupole line(x), the 1s2p 3p1 1s2 1S0 intercombination lines(y), the 1s2p 3S1-1s2 1S0 forbidden line(z) in helium-like Ti X XI and the 1s2s2p 2P3/2-1s22s 2S1/2 line(q) in lithium-like Ti X X have been recorded with a X-ray CCD camera. The experimental result shows that the wavelength resolution(λ/△λ) is above 1000 and the elliptical crystal spectrometer is suitable for X-ray spectroscopy.

  11. Measurement of Peltier Heat at the Solid/Liquid Interface and Its Application to Crystal Growth II : Measurement and Application

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.H. [Chungju National University, Chungju (Korea); Jang, K.W. [Hanseo University, Seosan (Korea); Lee, D.H. [Yonsei University, Seoul (Korea)

    1999-11-01

    Thermoelectric effects on the temperature changes at the solid- and liquid-phase and its interface were studied by using the unidirectional solidification of Bi{sub 2}Te{sub 3}. Cooling or heating effects measured with current density, polarity and current passing time were quite different. By separating sole Peltier, Thomson and Joule heat theoretically and experimentally, the Peltier coefficient at the solid/liquid interface of Bi{sub 2}Te{sub 3} was -1.10 X 10{sup -1} V, and the Thomson coefficients of solid- and liquid-phase were 7.31 X 10{sup -4} V/K, 5.77 X 10{sup -5}V/K, respectively. When D.C. passed from solid-phase to liquid-phase during the crystal growth of Bi{sub 2}Te{sub 3}, the crystal with more directionality was obtained owing to increase of the temperature gradient in liquid by the Peltier cooling. But in reverse current direction, the crystallinity was not changed significantly. (author). 10 refs., 7 figs., 1 tab.

  12. Ultrafast measurements of c-axis transport in single crystals of 2212-BSCCO

    CERN Document Server

    Fenton, J C

    2002-01-01

    The c-axis electrical conduction of the high-temperature cuprate superconductor Bi sub 2 Sr sub 2 CaCu sub 2 O sub sub + subdelta has been probed using small mesa structures fabricated on top of single-crystal samples. Such measurements are important because they give information which may be used to constrain theories for superconductivity in the cuprate superconductors. Previous measurements of c-axis tunnelling using mesa structures are reviewed. A system making use of cryogenically cooled buffer amplifiers has been developed. The system has been used to make measurements on mesa structures of Bi sub 2 Sr sub 2 CaCu sub 2 O sub 8 sub + subdelta with a time resolution better than 50 ns, faster than previously reported measurements. The system allows measurements free from the effects of heating to be made up to significantly higher currents than at dc. Measurements on a number of samples are presented. The measurements allow the backbending features often found in earlier work to be attributed to simple hea...

  13. Inductive measurement of optically hyperpolarized phosphorous donor nuclei in an isotopically enriched silicon-28 crystal.

    Science.gov (United States)

    Gumann, P; Patange, O; Ramanathan, C; Haas, H; Moussa, O; Thewalt, M L W; Riemann, H; Abrosimov, N V; Becker, P; Pohl, H-J; Itoh, K M; Cory, D G

    2014-12-31

    We experimentally demonstrate the first inductive readout of optically hyperpolarized phosphorus-31 donor nuclear spins in an isotopically enriched silicon-28 crystal. The concentration of phosphorus donors in the crystal was 1.5×10(15)  cm(-3), 3 orders of magnitude lower than has previously been detected via direct inductive detection. The signal-to-noise ratio measured in a single free induction decay from a 1  cm(3) sample (≈10(15) spins) was 113. By transferring the sample to an X-band ESR spectrometer, we were able to obtain a lower bound for the nuclear spin polarization at 1.7 K of ∼64%. The (31)P-T2 measured with a Hahn echo sequence was 420 ms at 1.7 K, which was extended to 1.2 s with a Carr Purcell cycle. The T1 of the (31)P nuclear spins at 1.7 K is extremely long and could not be determined, as no decay was observed even on a time scale of 4.5 h. Optical excitation was performed with a 1047 nm laser, which provided above-band-gap excitation of the silicon. The buildup of the hyperpolarization at 4.2 K followed a single exponential with a characteristic time of 577 s, while the buildup at 1.7 K showed biexponential behavior with characteristic time constants of 578 and 5670 s.

  14. Dielectric measurements of nanoliter liquids with a photonic crystal resonator at terahertz frequencies

    Science.gov (United States)

    Hanham, S. M.; Watts, C.; Otter, W. J.; Lucyszyn, S.; Klein, N.

    2015-07-01

    We present a highly sensitive technique for determining the complex permittivity of nanoliter liquid samples in the terahertz band based on a photonic crystal resonator and microcapillary. Liquids are characterized by using a capillary tube to introduce a ˜4 nl liquid sample into the electromagnetic field of a resonant mode confined by an L3 resonant cavity in a high-resistivity silicon photonic crystal slab. Monitoring the perturbation of the resonant frequency and unloaded Q-factor of the resonant mode at 100 GHz and ˜5800, respectively, allows a sample's permittivity to be calculated. An analytical model describing the system response based on perturbation theory and quasi-static analysis of the electric field within the capillary is also presented and found to agree well with FEM simulations and experimental measurements of ethanol-water mixtures of various concentrations for low to moderate loss tangents of the liquid samples. We demonstrate the utility of this approach by measuring the complex permittivity of several bioliquids, including suspensions of red and white blood cells. These results represent a step towards a lab-on-a-chip device for the analysis of extremely small quantities of biological, toxic, explosive, and other liquid types at terahertz frequencies.

  15. Single ice crystal measurements during nucleation experiments with the depolarization detector IODE

    Directory of Open Access Journals (Sweden)

    M. Nicolet

    2010-01-01

    Full Text Available In order to determine the efficiency of different aerosol particles to nucleate ice, an Ice Optical DEpolarization detector (IODE was developed to distinguish between water droplets and ice crystals in ice nucleation chambers. A laser beam polarized linearly (power: 50 mW, wavelength: 407 nm is directed through the chamber. The scattered light intensity from particles is measured at a scattering angle of Θ=175° in both polarization components (parallel and perpendicular. The ratio between the perpendicular intensity over the total one yields the depolarization ratio δ. Single particle detection is possible, using a peak detection algorithm. For high particle concentrations, a real-time signal averaging method can also be run simultaneously.

    The IODE detector was used in connection with the Zurich ice nucleation chamber during the ICIS 2007 workshop where ice nucleation experiments were performed with several aerosol types. In presence of ice crystals, a depolarization ratio could be measured on a particle-by-particle basis. Mean values of δ ranged from 0.24 to 0.37 and agree well with theoretical calculations.

  16. Single ice crystal measurements during nucleation experiments with the depolarization detector IODE

    Science.gov (United States)

    Nicolet, M.; Stetzer, O.; Lüönd, F.; Möhler, O.; Lohmann, U.

    2010-01-01

    In order to determine the efficiency of different aerosol particles to nucleate ice, an Ice Optical DEpolarization detector (IODE) was developed to distinguish between water droplets and ice crystals in ice nucleation chambers. A laser beam polarized linearly (power: 50 mW, wavelength: 407 nm) is directed through the chamber. The scattered light intensity from particles is measured at a scattering angle of Θ=175° in both polarization components (parallel and perpendicular). The ratio between the perpendicular intensity over the total one yields the depolarization ratio δ. Single particle detection is possible, using a peak detection algorithm. For high particle concentrations, a real-time signal averaging method can also be run simultaneously. The IODE detector was used in connection with the Zurich ice nucleation chamber during the ICIS 2007 workshop where ice nucleation experiments were performed with several aerosol types. In presence of ice crystals, a depolarization ratio could be measured on a particle-by-particle basis. Mean values of δ ranged from 0.24 to 0.37 and agree well with theoretical calculations.

  17. Time Dependent DD Neutrons Measurement Using a Single Crystal Chemical Vapor Deposition Diamond Detector on EAST

    Science.gov (United States)

    Du, Tengfei; Peng, Xingyu; Chen, Zhongjing; Hu, Zhimeng; Ge, Lijian; Hu, Liqun; Zhong, Guoqiang; Pu, Neng; Chen, Jinxiang; Fan, Tieshuan

    2016-09-01

    A single crystal chemical vapor deposition (scCVD) diamond detector has been successfully employed for neutron measurements in the EAST (Experimental Advanced Superconducting Tokamak) plasmas. The scCVD diamond detector coated with a 5 μm 6LiF (95% 6Li enriched) layer was placed inside a polyethylene moderator to enhance the detection efficiency. The time-dependent neutron emission from deuteron plasmas during neutral beam injection (NBI) heating was obtained. The measured results are compared with that of fission chamber detectors, which always act as standard neutron flux monitors. The scCVD diamond detector exhibits good reliability, stability and the capability to withstand harsh radiation environments despite its low detection efficiency due to the small active volume. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB106004 and 2012GB101003) and National Natural Science Foundation of China (No. 91226102)

  18. Electrical Conductivity of Synthetic Quartz Crystals at High Temperature and Pressure from Complex Impedance Measurements

    Institute of Scientific and Technical Information of China (English)

    王多君; 李和平; 刘丛强; 易丽; 丁东业; 苏根利; 张卫刚

    2002-01-01

    An electrical conductivity measurement system under high-pressure conditions with a multi-anvil high-pressure apparatus by an ac complex impedance method was set up. With this system, we have successfully measured the electrical conductivity of synthetic quartz under pressure up to approximately 1.0 GPa in the temperature range 661-987K. The values of electrical conductivity decrease with the increasing pressure and increase with the increasing temperature. The activation enthalpies for the α-quartz crystals are 1.10-1.28eV. The electrical conductivity of α-quartz is ionic, with Na ions moving in channels parallel to the c-axis being the predominant current carrier.

  19. Optical Absorption Measurements on Nitrogen-doped 6H-SiC Single Crystals

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    6H-SiC bulk crystals have been prepared by sublimation method in an inductively heated growth reactor. The effect of nitrogen doping on absorption for 6H-SiC was investigated. The absorption measurement based on optical method is a non-destructive and non-contact method. The band-gap narrowing with higher doping concentration was observed.For n-type doping below band-gap absorption band at 623 nm for 6H-SiC was observed. The peak intensity of the absorption band increased with increasing charge carrier concentration obtained from Hall measurements. It is also found that the nitrogen doping level decreased in the radial direction and it was the highest at the beginning of growth.

  20. Direct nanomechanical measurement of layer thickness and compressibility of smectic liquid crystals.

    Science.gov (United States)

    Carbone, Giovanni; Zappone, Bruno; Barberi, Riccardo; Bartolino, Roberto; Musevic, Igor

    2011-05-01

    Using an atomic force microscope (AFM) we confined a smectic-A liquid crystal (LC) between a flat glass plate and a 10-μm glass sphere attached to the free end of the AFM cantilever. Both surfaces were treated with a surfactant that induces normal alignment of the LC molecules. We measured the force F acting on the cantilever while varying the plate-sphere distance D with subnanometer precision. For D thickness a(0) and compressibility modulus B. Compared to other techniques used to determine a(0) and B, AFM measurements are faster and require a much smaller amount (microliters) of LC. Moreover, they are based on purely mechanical deformations of the LC structure and do not require any static or radiative electromagnetic field.

  1. The measurement of temperature with using of birefringence crystals as detectors

    Directory of Open Access Journals (Sweden)

    Gaba V. M.

    2009-02-01

    Full Text Available The carried out researches allowed to motivate and put into practice the polarizatoin-optical method of temperature measurement based on the phenomenon of temperature alteration in value of birefringence of the optically anisotropic crystals. The practical realization of the method with the use of Al2O3 and LiNbO3 plates as active elements of thermometers has shown, that the application of Al2O3 is more preferable due to a wide temperature interval of employment of material, its mechanical and chemical stability, absence of phase transitions. LiNbO3 has such lacks as nonlinearity of graduate dependence and presence of a phase transition point. Nevertheless, its use allows to raise the sensitivity of the thermometer and to increase the accuracy of measurements.

  2. Planar anchoring strength and pitch measurements in achiral and chiral chromonic liquid crystals using 90-degree twist cells

    Science.gov (United States)

    McGinn, Christine K.; Laderman, Laura I.; Zimmermann, Natalie; Kitzerow, Heinz-S.; Collings, Peter J.

    2013-12-01

    Chromonic liquid crystals are formed by molecules that spontaneously assemble into anisotropic structures in water. The ordering unit is therefore a molecular assembly instead of a molecule as in thermotropic liquid crystals. Although it has been known for a long time that certain dyes, drugs, and nucleic acids form chromonic liquid crystals, only recently has enough knowledge been gained on how to control their alignment so that studies of their fundamental liquid crystal properties can be performed. In this article, a simple method for producing planar alignment of the nematic phase in chromonic liquid crystals is described, and this in turn is used to create twisted nematic structures of both achiral and chiral chromonic liquid crystals. The optics of 90-degree twist cells allows the anchoring strength to be measured in achiral systems, which for this alignment technique is quite weak, about 3×10-7 J/m2 for both disodium cromoglycate and Sunset Yellow FCF. The addition of a chiral amino acid to the system causes the chiral nematic phase to form, and similar optical measurements in 90-degree twist cells produce a measurement of the intrinsic pitch of the chiral nematic phase. From these measurements, the helical twisting power for L-alanine is found to be (1.1±0.4)×10-2 μm-1 wt%-1 for 15 wt% disodium cromoglycate.

  3. Quick measurement of electrorheological effect for small amounts of nematic liquid crystal

    Science.gov (United States)

    Tadokoro, Chiharu; Hosomi, Yuki; Nakano, Ken

    2015-08-01

    A quick measurement method of effective viscosity, employing damped oscillation between two parallel plates, was proposed to examine the electrorheological (ER) effect for small amounts of nematic liquid crystal (LC). To demonstrate the validity of the method, the viscosity measurements were conducted for ordinary liquids [polyalphaolefins (PAOs)] and a nematic LC [4-pentyl-4‧-cyanobiphenyl (5CB)] by using a newly developed apparatus that embodied the measurement principle. The viscosity measurements for PAOs showed that when the film thickness is in the submillimeter range (e.g. 0.2 mm), this method provides reliable values of the effective viscosity. The viscosity measurement for 5CB showed that this method evaluates the ER effect with a few dozen cubic millimeters of the sample (e.g. 16 mm3) under the application of a voltage (e.g. 0 to 300 V). It was confirmed that the effective viscosities of 5CB measured at various conditions were scaled to a single master curve as a function of the applied voltage, effective velocity and film thickness.

  4. Focused beam reflectance measurement as a tool for in situ monitoring of the lactose crystallization process

    National Research Council Canada - National Science Library

    Pandalaneni, K; Amamcharla, J K

    2016-01-01

    .... Production of lactose is usually carried out by a process called crystallization. Several factors including rate of cooling, presence of impurities, and mixing speed influence the crystal size characteristics...

  5. Study of effect of quenching and deformation on KCl: Gd3+ crystals by using conductivity measurements

    Indian Academy of Sciences (India)

    G Saibabu; A Ramachandra Reddy; D Srikanth

    2004-10-01

    The study of ionic conductivity vs reciprocal temperature of pure KCl and KCl crystal doped with 0.1, 0.3 and 0.5 mole% gadolinium has been carried out in as grown, quenched from elevated temperatures (100, 350 and 500°C) and annealed at various timings i.e. 2–3 h and deformed by different percentages. The plots exhibit three well-known regions, II, III and IV (extrinsic regions). The intrinsic region I was not observed in the plots as the conductivity measurements were taken up to 575°C. From the analysis of these plots, activation energies for the migration of cation vacancy and the association of gadolinium ion with cation vacancy in the lattice of KCl crystals are calculated. These values are compared with previously reported values. Further, an attempt is made to explain the existence of oxidation state of gadolinium ion in + 3 state rather than in + 2 state as reported earlier. The variation in conductivity with effect of concentration of impurity ion, quenching and annealing and deformation with various percentages are explained on the basis of formation of impurity vacancy dipoles, vacancy – vacancy pairs (which appear in the form of precipitation), storage of cation vacancies in the form of defects, introduction of fresh dislocations, etc.

  6. Hybrid Young interferometer for high resolution measurement of dynamic speckle using high birefringence liquid crystal

    Science.gov (United States)

    Bennis, N.; Holdynski, Z.; Merta, I.; Marc, P.; Kula, P.; Mazur, R.; Piecek, W.; Jaroszewicz, L. R.

    2015-08-01

    It is well known that the Young interference experiment is the fundamental setup to combine two beams and to construct the phase modulated light. Moreover, homodyne phase demodulator is based on signal decoding in back Fourier focal plane using bicell photodetector (B-PD). On the above base, we propose a novel experimental approach to the signals demodulation by using the optical interferometer which operates in homodyne mode, combined with liquid crystal spatial light modulators operating both phase as speckle modulator. Dynamic phase changes between the two beams can be controlled by monopixel liquid crystals cell placed in one branch of the interferometer. A phase modulation effect in a signal arm of interferometer is observed as a dynamic shift of the speckle pattern. Simple arithmetic combination of signals from B-PD placed in speckle pattern plane is only one necessary numerical manipulation to obtain exactly phase difference. Concept of signals demodulation in the Fourier focal plane can be only used for exactly defined geometrical (B-PD as well as Young interferometer) and physical parameters (polarization, wavelength). We optimize the setup geometry to obtain extremely high measurement resolution. In this paper we focus on the principles of operation of each part of the system as well as discussion their requirement in order to increase the signal to noise ratio.

  7. Single ice crystal measurements during nucleation experiments with the depolarization detector IODE

    Directory of Open Access Journals (Sweden)

    M. Nicolet

    2008-12-01

    Full Text Available In order to determine the efficiency of aerosol particles of several types to nucleate ice, an Ice Optical DEpolarization detector (IODE was developed to distinguish between water droplets and ice crystals in ice nucleation chambers. A laser beam polarized linearly (power: 50 mW, wavelength: 407 nm is directed through the chamber. The scattered light intensity from particles is measured at a scattering angle of Θ=175° in both polarization components (parallel and perpendicular. The ratio between the perpendicular intensity over the total one gives the depolarization ratio δ. Single particle detection is possible, using a peak detection algorithm. For high particle concentrations, a real-time signal averaging method can also be run simultaneously. The IODE detector was used in connection with the Zurich ice nucleation chamber during the ICIS 2007 workshop where ice nucleation experiments were performed with several aerosol types. In presence of ice crystals, peaks were detected in both channels, generating depolarization signals. Mean values of δ ranged from 0.24 to 0.37.

  8. Precision Measurements of Light Quenching in CaWO$_4$ Crystals at mK Temperatures

    CERN Document Server

    Strauss, R; Bento, A; Bucci, C; Canonica, L; Carli, W; Ciemniak, C; Erb, A; Feilitzsch, F v; Gorla, P; Gütlein, A; Hagn, H; Hauff, D; Hellgartner, D; Jochum, J; Kraus, H; Lanfranchi, J -C; Loebell, J; Münster, A; Petricca, F; Potzel, W; Pröbst, F; Reindl, F; Roth, S; Rottler, K; Sailer, C; Schäffner, K; Schieck, J; Scholl, S; Schönert, S; Seidel, W; Sivers, M v; Stodolsky, L; Strandhagen, C; Tanzke, A; Uffinger, M; Ulrich, A; Usherov, I; Wawoczny, S; Willers, M; Wüstrich, M; Zöller, A

    2014-01-01

    Scintillating CaWO$_4$ single crystals are a promising multi-element target for rare-event searches and are currently used in the direct Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an active background discrimination and the identification of a possible signal induced by weakly interacting massive particles (WIMPs). We present the first precise measurements of the QFs of O, Ca and W at mK temperatures by irradiating a cryogenic detector with a fast neutron beam. A clear energy dependence of the QFs and a variation between different CaWO$_4$ single crystals were observed for the first time. For typical CRESST detectors the QFs in the region-of-interest (10-40$\\,$keV) are $QF_O^{ROI}=(11.2\\pm0.5)\\,$%, $QF_{Ca}^{ROI}=(5.94\\pm0.49)\\,$% and $QF_W^{ROI}=(1.72\\pm0.21)\\,$%. The latest CRESST data (run32) is reanalyzed using these ...

  9. Interactions between Rotavirus and Suwannee River Organic Matter: Aggregation, Deposition, and Adhesion Force Measurement

    KAUST Repository

    Gutierrez, Leonardo

    2012-08-21

    Interactions between rotavirus and Suwannee River natural organic matter (NOM) were studied by time-resolved dynamic light scattering, quartz crystal microbalance, and atomic force microscopy. In NOM-containing NaCl solutions of up to 600 mM, rotavirus suspension remained stable for over 4 h. Atomic force microscopy (AFM) measurement for interaction force decay length at different ionic strengths showed that nonelectrostatic repulsive forces were mainly responsible for eliminating aggregation in NaCl solutions. Aggregation rates of rotavirus in solutions containing 20 mg C/L increased with divalent cation concentration until reaching a critical coagulation concentration of 30 mM CaCl2 or 70 mM MgCl2. Deposition kinetics of rotavirus on NOM-coated silica surface was studied using quartz crystal microbalance. Experimental attachment efficiencies for rotavirus adsorption to NOM-coated surface in MgCl2 solution were lower than in CaCl2 solution at a given divalent cation concentration. Stronger adhesion force was measured for virus-virus and virus-NOM interactions in CaCl2 solution compared to those in MgCl2 or NaCl solutions at the same ionic strength. This study suggested that divalent cation complexation with carboxylate groups in NOM and on virus surface was an important mechanism in the deposition and aggregation kinetics of rotavirus. © 2012 American Chemical Society.

  10. Measurement of transmission and reflection from a thick anisotropic crystal modeled by a sum of incoherent partial waves.

    Science.gov (United States)

    Nichols, Shane; Arteaga, Oriol; Martin, Alexander; Kahr, Bart

    2015-11-01

    Formulas for modeling ellipsometric measurements of bianisotropic crystals assume perfectly coherent plane wave illumination. As such, the finite coherence of typical spectroscopic ellipsometers renders such formulas invalid for crystals thicker than a few micrometers. Reflection measurements of thick crystalline slabs show depolarization. Researchers have proposed strategies for the full accounting for multiply reflected incoherent waves in anisotropic, arbitrarily oriented crystals [Appl. Opt.41, 2521 (2002).APOPAI0003-693510.1364/AO.41.002521], but to the best of our knowledge these methods have not been tested by explicit measurements. It is shown that by a summation of multiply reflected incoherent waves, transmission and reflection measurements of thick quartz slabs can be interpreted in terms of the constitutive material parameters.

  11. Liquid crystal modified photonic crystal fiber (LC-PCF) fabricated with an un-cured SU-8 photoresist sealing technique for electrical flux measurement.

    Science.gov (United States)

    Kuo, Shu-Ming; Huang, Yu-Wen; Yeh, Szu-Ming; Cheng, Wood-Hi; Lin, Che-Hsin

    2011-09-12

    The optical transmission properties of photonic crystal fibers (PCFs) can be manipulated by modifying the pattern arrangement of the air channels within them. This paper presents a novel MEMS-based technique for modifying the optical transmission properties of commercial photonic-crystal fiber (PCF) by selectively filling the voids within the fiber structure with liquid crystals. In the proposed approach, an un-cured SU-8 ring pattern with a thickness of 5 μm is fabricated using a novel stamping method. The PCF is then brought into contact with the SU-8 pattern and an infra-red (IR) laser beam is passed through the fiber in order to soften the SU-8 surface; thereby selectively sealing some of the air channels with molten SU-8. Liquid crystals (LCs) are then infiltrated into the un-sealed holes in the PCF via capillary effects in order to modify the transmission properties of the PCF. Two selectively-filled PCFs are fabricated, namely an inner-ring LC-PCF and a single-line LC-PCF, respectively. It is shown that the two LC-PCFs exhibit significantly different optical behaviors. The practical applicability of the proposed selective-filling approach is demonstrated by fabricating an electric field sensor. The experimental results show that the sensor has the ability to measure electric fields with an intensity of up to 40 kV/cm.

  12. Copper and silver selenide crystal growth rate measurements as a method for determination of ionic conductivity

    Science.gov (United States)

    Vučić, Zlatko; Lovrić, Davorin; Gladić, Jadranko; Etlinger, Božidar

    2004-03-01

    The motivation behind this work is the discrepancy between the measured and calculated growth rates of copper selenide spherical single crystals between 740 and 800 K. The growth of cylindrical polycrystalline samples of copper selenide at high temperatures was monitored in experiments that enabled full control of the geometry of growth. Together with the calculations based on Yokota's transport equation, these measurements eliminated ionic conductivity data as a possible reason behind too high values of the calculated growth rates. The equivalent growth experiments on polycrystalline silver selenide samples were performed as a test of the method, yielding excellent agreement with the results obtained by extrapolation of existing data. On the basis of these measurements and associated analysis, this method is proposed as a method for determination of ionic conductivity of mixed superionic conductors on temperatures up to the temperatures of melting, i.e. in the range in which other methods of ionic conductivity measurements either do not work or are not accurate enough.

  13. Seebeck Coefficient Measurements on Micron-Size Single-Crystal Zinc Germanium Nitride Rods

    Science.gov (United States)

    Dyck, J. S.; Colvin, J. R.; Quayle, P. C.; Peshek, T. J.; Kash, K.

    2016-06-01

    II-IV-nitride compounds are tetrahedrally bonded, heterovalent ternary semiconductors that have recently garnered attention for their potential technological applications. These materials are derived from the parent III-nitride compounds; ZnGeN2 is the II-IV-nitride analogue to the III-nitride GaN. Very little is known about the transport properties of ZnGeN2. In this work, we present Seebeck coefficient ( S) data on 3-micron-diameter, 70-micron-long, single-crystal ZnGeN2 rods, employing a novel measurement approach. The measurements of S show that the majority free carriers are electrons, and imply that the carrier gas is degenerate. Within a single-band model for the conduction band, a carrier concentration of order 1019 cm-3 was estimated for a measured S = -90 μV/K. Together with electrical transport measurements, a lower limit for the electron mobility is estimated to be ˜20 cm2/V-s. A discussion of this material as a thermoelectric is presented. The background level of free electrons in this unintentionally doped ZnGeN2 is very near the predicted optimum value for maximum thermoelectric performance.

  14. Surface Impedance Measurements of Single Crystal MgB2 Films for Radiofrequency Superconductivity Applications

    Energy Technology Data Exchange (ETDEWEB)

    Binping Xiao, Xin Zhao, Joshua Spradlin, Charles Reece, Michael Kelley, Teng Tan, Xi Xiaoxing

    2012-07-01

    We report microstructure analyses and superconducting radiofrequency (SRF) measurements of large scale epitaxial MgB{sub 2} films. MgB{sub 2} films on 5 cm dia. sapphire disks were fabricated by a Hybrid Physical Chemical Vapor Deposition (HPCVD) technique. The electron-beam backscattering diffraction (EBSD) results suggest that the film is a single crystal complying with a MgB{sub 2}(0001) {parallel} Al{sub 2}O{sub 3}(0001) epitaxial relationship. The SRF properties of different film thicknesses (200 nm and 350 nm) were evaluated under different temperatures and applied fields at 7.4 GHz. A surface resistance of 9 {+-} 2 {mu}{Omega} has been observed at 2.2 K.

  15. Long-period grating and its cascaded counterpart in photonic crystal fiber for gas phase measurement.

    Science.gov (United States)

    Tian, Fei; Kanka, Jiri; Du, Henry

    2012-09-10

    Regular and cascaded long period gratings (LPG, C-LPG) of periods ranging from 460 to 590 μm were inscribed in an endlessly single mode photonic crystal fiber (PCF) using CO(2) laser for sensing measurements of helium, argon and acetylene. High index sensitivities in excess of 1700 nm/RIU were achieved in both grating schemes with a period of 460 μm. The sharp interference fringes in the transmission spectrum of C-PCF-LPG afforded not only greatly enhanced sensing resolution, but also accuracy when the phase-shift of the fringe pattern is determined through spectral processing. Comparative numerical and experimental studies indicated LP(01) to LP(03) mode coupling as the principal coupling step for both PCF-LPG and C-PCF-LPG with emergence of multi-mode coupling at shorter grating periods or longer resonance wavelengths.

  16. Coupled stress-strain and electrical resistivity measurements on copper based shape memory single crystals

    Directory of Open Access Journals (Sweden)

    Gonzalez Cezar Henrique

    2004-01-01

    Full Text Available Recently, electrical resistivity (ER measurements have been done during some thermomechanical tests in copper based shape memory alloys (SMA's. In this work, single crystals of Cu-based SMA's have been studied at different temperatures to analyse the relationship between stress (s and ER changes as a function of the strain (e. A good consistency between ER change values is observed in different experiments: thermal martensitic transformation, stress induced martensitic transformation and stress induced reorientation of martensite variants. During stress induced martensitic transformation (superelastic behaviour and stress induced reorientation of martensite variants, a linear relationship is obtained between ER and strain as well as the absence of hys teresis. In conclusion, the present results show a direct evidence of martensite electrical resistivity anisotropy.

  17. Sensitive temperature measurements based on Lorentzian and Fano resonance lineshapes of a silicon photonic crystal cavity

    Science.gov (United States)

    Zhao, Chenyang; Fang, Liang; Yuan, Qinchen; Gan, Xuetao; Zhao, Jianlin

    2016-10-01

    We report a high-performance photonic temperature sensor by exploiting a silicon photonic crystal (PC) cavity. Since the PC cavity's spectra are very sensitive to the refractive index change, we observe remarkable variations of its resonant wavelength and output power under varying temperature levels. In a PC cavity with Lorentzian resonance lineshape, the sensor exhibits a linear spectrum-sensitivity of 70 pm/°, and the power-variation presents a high sensitivity as 1.28 dB/°. In addition, the Fano resonance lineshape generated by the PC cavity has also been employed to measure the temperature, which shows improved power sensitivity as 2.94 dB/ °. The demonstrated PC cavity-based sensor offers great potentials for low-cost, high sensitivity homogeneous sensing in chip-integrated devices.

  18. Aerometric measurement and modeling of the mass of CO2 emissions from Crystal Geyser, Utah

    Energy Technology Data Exchange (ETDEWEB)

    Gouveia, F J; Johnson, M R; Leif, R N; Friedmann, S J

    2005-02-07

    Crystal Geyser in eastern Utah is a rare, non-geothermal geyser that emits carbon dioxide gas in periodic eruptions. This geyser is the largest single source of CO{sub 2} originating from a deep reservoir. For this study, the amount of CO{sub 2} emitted from Crystal Geyser is estimated through measurements of downwind CO{sub 2} air concentration applied to an analytical model for atmospheric dispersion. Five eruptions occurred during the 48-hour field study, for a total of almost 3 hours of eruption. Pre-eruption emissions were also timed and sampled. Slow wind during three of the active eruptions conveyed the plume over a grid of samplers arranged in arcs from 25 to 100 m away from the geyser. An analytical, straight-line Gaussian model matched the pattern of concentration measurements. Plume width was determined from least-squares fit of the CO{sub 2} concentrations integrated over time. The CO{sub 2} emission rate was found to be between 2.6 and 5.8 kg/s during the eruption events, and about 0.17 kg/s during the active pre-eruptive events. Our limited field study can be extrapolated to an annual CO{sub 2} emission of 12 kilotonnes from this geyser. As this is the first application of Gaussian dispersion modeling and objective timing to CO{sub 2} emissions from a geyser of any type, the present study demonstrates the feasibility of applying this method more completely in the future.

  19. Magnetic measurements and crystal field investigation on single crystals of Er(CF{sub 3}SO{sub 3}){sub 3}.9H{sub 2}O

    Energy Technology Data Exchange (ETDEWEB)

    Bisui, D. [Solid State Research Laboratory, Department of Physics, Burdwan University, Burdwan 713 104, West Bengal (India); Chattopadhyay, K.N. [Institute of Science Education, Burdwan University, Burdwan 713 104, West Bengal (India); Chakrabarti, P.K. [Solid State Research Laboratory, Department of Physics, Burdwan University, Burdwan 713 104, West Bengal (India)], E-mail: pabitra_c@hotmail.com

    2008-02-15

    Single crystals of erbium tri-fluoromethanesulfonate (ErTFMS) were prepared from the slow evaporation of the aqueous solution. The principal magnetic susceptibilities perpendicular to the c-axis of the hexagonal crystal was measured down to 13 K. Principal magnetic anisotropy was also measured from 300 K down to 80 K which provides principal susceptibility parallel to the c-axis down to 80 K. A very good theoretical simulation of the thermal variation of principal magnetic susceptibilities of ErTFMS has been obtained with a crystal field (CF) of C{sub 3h} site symmetry, in which J-mixed eigenvectors and intermediate coupling effects have been used. No ordering effects were noticed down to the lowest temperature (13 K) attained, indicating the inter-ionic interaction to be of predominantly dipolar type. The g-values are found to be g{sub parallel}=8.86 and g{sub perpendicular}=1.62, respectively. The Schottky anomaly in the electronic heat capacity at about 80 K has been computed from the Stark pattern. The thermal behavior of quadrupole splitting and hyperfine heat capacity were calculated from the CF analysis.

  20. Dielectric and electro-optic measurements of nematic liquid crystals doped with carbon nanotubes

    Science.gov (United States)

    Peterson, Matthew; Georgiev, Georgi; Atherton, Timothy; Cebe, Peggy

    We studied the effects of carbon nanotubes (CNTs) on the dielectric and electro-optic properties of nematic 5CB liquid crystals (LCs). Samples containing 0.01%, 0.10% and 1.00% CNTs by weight were prepared. Anti- parallel rubbed cells with a nominal thickness of 10 μm were prepared using indium tin oxide coated glass cells and a polyimide alignment layer. The capacitance and dissipation factor were measured using an Agilent 4284A precision LCR meter. From these measurements, the complex dielectric permittivity was determined as a function of frequency. Analysis of the low frequency regime (f <1000 Hz) indicates that 5CB samples containing CNTs have a higher conductance than neat samples. The Fréedericksz transition critical voltage was noted by a sharp increase in capacitance after an initial plateau. Numerical simulations of CNT-facilitated switching show that polarization induced on the nanotubes from capacitive effects can significantly reduce the critical voltage in DC electric fields, in agreement with experimental results. Measurements of the critical voltage over a range of frequencies will also be presented. Research was supported by the National Science Foundation, DMR1206010.

  1. Method to measure the phase modulation characteristics of a liquid crystal spatial light modulator.

    Science.gov (United States)

    Wu, Yunlong; Nie, Jinsong; Shao, Li

    2016-11-01

    The universal liquid crystal spatial light modulator (LC-SLM) is widely used in many aspects of optical studies. The working principles and applications of LC-SLM were introduced briefly. The traditional Twyman-Green interference method, which was used to measure the phase modulation characteristics of a liquid spatial light modulator, had some obvious disadvantages in practice. To avoid these issues, the traditional Twyman-Green interference method was improved. Also, a new method to process interference fringes and measure the shift distances and cycles automatically by computers was proposed. The phase modulation characteristics of P512-1064 LC-SLM produced by the Meadowlark Company were measured to verify the validity of the newly proposed method. In addition, in order to compensate and correct the nonlinear characteristics of the phase modulation curve, three universal inverse interpolation methods were utilized. The root mean squared error and residual sum of squares between the calibrated phase modulation curve and the ideal phase modulation curve were reduced obviously by taking advantage of the inverse interpolation methods. Subsequently, the method of shape-preserving subsection cubic interpolation had acquired the best performance with high computation efficiency. Experiments have been performed to verify the validity of the interpolation method. The experimental results showed that the phase modulation characteristics of LC-LSM could be acquired and calibrated automatically with convenience and high efficiency by utilizing the newly proposed processing method.

  2. Measurements of Al concentration in the primary Si crystals from the rheocast Al-15.5 wt% Si alloy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G.H.; Lee, J.C.; Lee, H.I. [Korea Inst. of Science and Technology, Seoul (Korea, Republic of); Lee, J.I. [Chungju National Univ. (Korea, Republic of). Dept. of Materials Science and Engineering

    1997-10-01

    The purpose of the present study is to investigate the distribution of Al in the primary crystal of Si in rheocast hypereutectic Al-Si alloy. Lattice parameters of primary Si crystals were determined using relative positions of the higher order Laue zone (HOLZ) lines recorded from the CBED patterns. The measured lattice parameters were then converted to the Al concentrations to compare with EPMA measurements for the accurate determination of solute concentration profile in the primary Si and to understand the role of solute redistribution on the microstructural change in hypereutectic Al-Si alloy during rheocasting.

  3. Magnetization measurements on HoNi{sub 2}B{sub 2}C single crystals before and after neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fuger, R. [Atomic Institute of the Austrian Universities, 1020 Vienna (Austria)], E-mail: rfuger@ati.ac.at; Krutzler, C. [Atomic Institute of the Austrian Universities, 1020 Vienna (Austria); Fuchs, G.; Behr, G. [Institut fuer Festkoerper- und Werkstofforschung Dresden, 14109 Dresden (Germany); Weber, H.W. [Atomic Institute of the Austrian Universities, 1020 Vienna (Austria)

    2007-09-01

    A single crystal of HoNi{sub 2}B{sub 2}C was fully characterised by magnetization measurements. The magnetic and the superconducting phase diagram were determined in different crystal directions and the superconductive properties evaluated as a function of temperature and applied field. The critical current density was calculated from magnetization loops using the Bean model. The results on the critical current density reveal bulk pinning in those regions of the phase diagram, where superconductivity is not suppressed by metamagnetically ordered structures of the Ho 4f-moments. These measurements were repeated after neutron irradiation of the sample.

  4. Crystal surface integrity and diffusion measurements on Earth and planetary materials

    Science.gov (United States)

    Watson, E. B.; Cherniak, D. J.; Thomas, J. B.; Hanchar, J. M.; Wirth, R.

    2016-09-01

    Characterization of diffusion behavior in minerals is key to providing quantitative constraints on the ages and thermal histories of Earth and planetary materials. Laboratory experiments are a vital source of the needed diffusion measurements, but these can pose challenges because the length scales of diffusion achievable in a laboratory time are commonly less than 1 μm. An effective strategy for dealing with this challenge is to conduct experiments involving inward diffusion of the element of interest from a surface source, followed by quantification of the resulting diffusive-uptake profile using a high-resolution depth-profiling technique such as Rutherford backscattering spectroscopy (RBS), nuclear reaction analysis (NRA), or ion microprobe (SIMS). The value of data from such experiments is crucially dependent on the assumption that diffusion in the near-surface of the sample is representative of diffusion in the bulk material. Historical arguments suggest that the very process of preparing a polished surface for diffusion studies introduces defects-in the form of dislocations and cracks-in the outermost micrometer of the sample that make this region fundamentally different from the bulk crystal in terms of its diffusion properties. Extensive indirect evidence suggests that, in fact, the near-surface region of carefully prepared samples is no different from the bulk crystal in terms of its diffusion properties. A direct confirmation of this conclusion is nevertheless clearly important. Here we use transmission electron microscopy to confirm that the near-surface regions of olivine, quartz and feldspar crystals prepared using careful polishing protocols contain no features that could plausibly affect diffusion. This finding does not preclude damage to the mineral structure from other techniques used in diffusion studies (e.g., ion implantation), but even in this case the role of possible structural damage can be objectively assessed and controlled. While all

  5. Large surface radiative forcing from surface-based ice crystal events measured in the High Arctic at Eureka

    Directory of Open Access Journals (Sweden)

    G. Lesins

    2008-09-01

    Full Text Available Ice crystals, also known as diamond dust, are suspended in the boundary layer air under clear sky conditions during most of the Arctic winter in Northern Canada. Occasionally ice crystal events can produce significantly thick layers with optical depths in excess of 2.0 even in the absence of liquid water clouds. Four case studies of high optical depth ice crystal events at Eureka in the Nunavut Territory of Canada during the winter of 2006–2007 are presented. They show that the measured ice crystal surface infrared downward radiative forcing ranged from 8 to 36 W m−2 in the wavelength band from 5.6 to 20 μm for visible optical depths ranging from 0.2 to 1.7. MODIS infrared and visible images and the operational radiosonde wind profile were used to show that these high optical depth events were caused by surface snow being blown off 600 to 800 m high mountain ridges about 20 to 30 km North-West of Eureka and advected by the winds towards Eureka as they settled towards the ground within the highly stable boundary layer. This work presents the first study that demonstrates the important role that surrounding topography plays in determining the occurrence of high optical depth ice crystal events and points to a new source of boundary layer ice crystal events distinct from the classical diamond dust phenomenon.

  6. Study on the spectrum of photonic crystal cavity and its application in measuring the concentration of NaCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yun [Nanjing Agricultural Univ., Nanjing (China). Dept. of Physics; Wuxi Institute of Commerce, Wuxi (China). School of Electromechanical Technology; Xie, Xun; Hao, Jiong-Ju; Yang, Hong-Wei [Nanjing Agricultural Univ., Nanjing (China). Dept. of Physics; Yang, Ze-Kun [Lanzhou Univ. (China). School of Information Science and Engineering; Xu, Zhi-Gang [Nanjing Agricultural Univ., Nanjing (China). College of Agriculture

    2017-07-01

    In this article, we propose an approach to measure solution concentrations by using photonic crystal cavities. Based on the experimental data, the refractive index of a NaCl solution is proportional to the concentration. Filling the proposed photonic crystal cavity with a NaCl solution, we calculate the spectral transmission using the transfer matrix method. We found that the cavity transmittance was proportional to the refractive index of the NaCl solution, and thus we obtained a linear relationship between cavity transmittance and the concentration of the NaCl solution. The formula was found by fitting the simulation results with experimental data. Such a formula can be applied to the measurement of an unknown concentration of NaCl solution utilizing a photonic crystal cavity.

  7. The CMS Electromagnetic Calorimeter: Results on Crystal Measurements, Quality Control and Data Management in the Rome Regional Center

    CERN Document Server

    Costantini, S

    2004-01-01

    The barrel of the CMS electromagnetic calorimeter is currently under construction and will contain 61200 PbWO4 crystals. Half of them are being fully characterized for dimensions, optical properties and light yield in the INFN-ENEA Regional Center near Rome. We describe the setup of an automatic quality control system for the crystal measurements and the present results on their qualification, as well as the REDACLE project, which has been developed to control and ease the production process. As it will not be possible to precalibrate the whole calorimeter,the crystal measurements and quality checks performed at the Regional Center will be crucial to provide a basis for fast in-situ calibration with particles. REDACLE is at the same time a fast database and a data management system, where the database and the workflow structures are decoupled, in order to obtain the best flexibility.

  8. Measurement of Coherent Emission and Linear Polarization of Photons by Electrons in the Strong Fields of Aligned Crystals

    CERN Document Server

    Apyan, A; Badelek, B; Ballestrero, S; Biino, C; Birol, I; Cenci, P; Connell, S H; Eichblatt, S; Fonseca, T; Freund, A; Gorini, B; Groess, R; Ispirian, K; Ketel, T; Kononets, Yu V; López, A; Mangiarotti, A; Van Rens, B; Sellschop, J P Friedel; Shieh, M; Sona, P; Strakhovenko, V M; Uggerhøj, Erik; Uggerhøj, U; Ünel, G; Velasco, M; Vilakazi, Z Z; Wessely, O; Kononets, Yu.V.

    2004-01-01

    We present new results regarding the features of high energy photon emission by an electron beam of 178 GeV penetrating a 1.5 cm thick single Si crystal aligned at the Strings-Of-Strings (SOS) orientation. This concerns a special case of coherent bremsstrahlung where the electron interacts with the strong fields of successive atomic strings in a plane and for which the largest enhancement of the highest energy photons is expected. The polarization of the resulting photon beam was measured by the asymmetry of electron-positron pair production in an aligned diamond crystal analyzer. By the selection of a single pair the energy and the polarization of individual photons could be measured in an the environment of multiple photons produced in the radiator crystal. Photons in the high energy region show less than 20% linear polarization at the 90% confidence level.

  9. Isotope shifts of natural Sr+ measured by laser fluorescence in a sympathetically cooled Coulomb crystal

    CERN Document Server

    Dubost, Brice; Szymanski, Benjamin; Guibal, Samuel; Likforman, Jean-Pierre; Guidoni, Luca

    2014-01-01

    We measured by laser spectroscopy the isotope shifts between naturally-occurring even-isotopes of strontium ions for both the $5s\\,\\,^2S_{1/2}\\to 5p\\,\\,^2P_{1/2}$ (violet) and the $4d\\,\\,^2D_{3/2}\\to 5p\\,\\,^2P_{1/2}$ (infrared) dipole-allowed optical transitions. Fluorescence spectra were taken by simultaneous measurements on a two-component Coulomb crystal in a linear Paul trap containing $10^3$--$10^4$ laser-cooled Sr$^+$ ions. The isotope shifts are extracted from the experimental spectra by fitting the data with the analytical solution of the optical Bloch equations describing a three-level atom in interaction with two laser beams. This technique allowed us to increase the precision with respect to previously reported data obtained by optogalvanic spectroscopy or fast atomic-beam techniques. The results for the $5s\\,\\,^2S_{1/2}\\to 5p\\,\\,^2P_{1/2}$ transition are $\

  10. Measurement and analysis of the mannitol partition coefficient in sucrose crystallization under simulated industrial conditions

    Science.gov (United States)

    Mannitol is a major deterioration product of Leuconstoc mesenteroides bacterial deterioration of both sugarcane and sugar beet. The effect of crystallization conditions on the mannitol partition coefficient (Keff) between impure sucrose syrup and crystal has been investigated in a batch laboratory c...

  11. arXiv Feasibility of measuring the magnetic dipole moments of the charm baryons at the LHC using bent crystals

    CERN Document Server

    Bezshyyko, O.A.; Fomin, A.S.; Fomin, S.P.; Kirillin, I.V.; Korchin, A. Yu.; Massacrier, L.; Natochii, A.; Robbe, P.; Scandale, W.; Shul'ga, N.F.; Stocchi, A.

    2017-08-28

    In this paper we revisit the idea of measuring the magnetic dipole moments of the charm baryons and, in particular, of charmed Lambda by studying the spin precession induced by the strong effective magnetic field inside the channels of a bent crystal. We present a detailed sensitivity study showing the feasibility of such an experiment at the LHC in the coming years.

  12. Extreme UV and X-ray scattering measurements from a rough LiF crystal surface characterized by electron micrography

    DEFF Research Database (Denmark)

    Alehyane; Arbaoui; Barchewitz

    1989-01-01

    XUV and X-ray scattering by a LiF crystal is measured. The angular distribution of the scattered radiation (ADSR) reveals characteristic features, side peaks or asymmetry. The surface of the sample is statistically characterized by a microdensitometer analysis of electron micrographs resolving th...

  13. Statistical measurements of quantum emitters coupled to Anderson-localized modes in disordered photonic-crystal waveguides

    NARCIS (Netherlands)

    Javadi, A.; Maibom, S.; Sapienza, L.; Thyrrestrup Nielsen, H.; Garcia, P.D.; Lodahl, P.

    2014-01-01

    We present a statistical study of the Purcell enhancement of the light emission from quantum dots coupled to Anderson-localized cavities formed in disordered photonic-crystal waveguides. We measure the time-resolved light emission from both single quantum emitters coupled to Anderson-localized cavit

  14. Comment on ``Photoselection in uniaxial liquid crystals: The effect of rotational Brownian motion on measurements of orientational distribution functions''

    DEFF Research Database (Denmark)

    DuPré, Donald B.; Chapoy, L. Lawrence

    1980-01-01

    The effect of rotational Brownian motion on measurements of orientational distribution functions in uniaxial liquid crystals is discussed. The comments of Naqvi1 on the authors previously published2,3 papers are answered.(AIP) The Journal of Chemical Physics is copyrighted by The American Institute...

  15. Advanced Optical Diagnostics for Ice Crystal Cloud Measurements in the NASA Glenn Propulsion Systems Laboratory

    Science.gov (United States)

    Bencic, Timothy J.; Fagan, Amy; Van Zante, Judith F.; Kirkegaard, Jonathan P.; Rohler, David P.; Maniyedath, Arjun; Izen, Steven H.

    2013-01-01

    A light extinction tomography technique has been developed to monitor ice water clouds upstream of a direct connected engine in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center (GRC). The system consists of 60 laser diodes with sheet generating optics and 120 detectors mounted around a 36-inch diameter ring. The sources are pulsed sequentially while the detectors acquire line-of-sight extinction data for each laser pulse. Using computed tomography algorithms, the extinction data are analyzed to produce a plot of the relative water content in the measurement plane. To target the low-spatial-frequency nature of ice water clouds, unique tomography algorithms were developed using filtered back-projection methods and direct inversion methods that use Gaussian basis functions. With the availability of a priori knowledge of the mean droplet size and the total water content at some point in the measurement plane, the tomography system can provide near real-time in-situ quantitative full-field total water content data at a measurement plane approximately 5 feet upstream of the engine inlet. Results from ice crystal clouds in the PSL are presented. In addition to the optical tomography technique, laser sheet imaging has also been applied in the PSL to provide planar ice cloud uniformity and relative water content data during facility calibration before the tomography system was available and also as validation data for the tomography system. A comparison between the laser sheet system and light extinction tomography resulting data are also presented. Very good agreement of imaged intensity and water content is demonstrated for both techniques. Also, comparative studies between the two techniques show excellent agreement in calculation of bulk total water content averaged over the center of the pipe.

  16. Isotope shifts of natural Sr+ measured by laser fluorescence in a sympathetically cooled Coulomb crystal

    Science.gov (United States)

    Dubost, B.; Dubessy, R.; Szymanski, B.; Guibal, S.; Likforman, J.-P.; Guidoni, L.

    2014-03-01

    We measured by laser spectroscopy the isotope shifts between naturally occurring even isotopes of strontium ions for both the 5s2S1/2→5p2P1/2 (violet) and the 4d2D3/2→5p2P1/2 (infrared) dipole-allowed optical transitions. Fluorescence spectra were taken by simultaneous measurements on a two-component Coulomb crystal in a linear Paul trap containing 103-104 laser-cooled Sr+ ions. The isotope shifts are extracted from the experimental spectra by fitting the data with the analytical solution of the optical Bloch equations describing a three-level atom interacting with two laser beams. This technique allowed us to increase the precision with respect to previously reported data obtained by optogalvanic spectroscopy or fast atomic-beam techniques. The results for the 5s2S1/2→5p2P1/2 transition are ν88-ν84=+378(4) MHz and ν88-ν86=+170(3) MHz, in agreement with previously reported measurements. In the case of the previously unexplored 4d2D3/2→5p2P1/2 transition we find ν88-ν84=-828(4) MHz and ν88-ν86=-402(2) MHz. These results provide more data for stringent tests of theoretical calculations of the isotope shifts of alkali-metal-like atoms. Moreover, they simplify the identification and the addressing of Sr+ isotopes for ion frequency standards or quantum-information-processing applications in the case of multi-isotope ion strings.

  17. Use of focused beam reflectance measurement (FBRM) and process video imaging (PVI) in a modified mixed suspension mixed product removal (MSMPR) cooling crystallizer

    Science.gov (United States)

    Kougoulos, E.; Jones, A. G.; Jennings, K. H.; Wood-Kaczmar, M. W.

    2005-01-01

    The FBRM instrument is a 'powerful' tool developed by Lasentec as an 'in situ' particle monitoring technique for in-line real-time measurement of particle size. This technique was successfully used to monitor steady-state operation in a modified MSMPR crystallizer. The FBRM technique was also used to estimate crystallization kinetics. The FBRM particle size measurements were complimented by an in-line process video imaging (PVI) system developed ' in-house' (Microscopy and Microanalysis, 6 (Suppl. 2) (2000) 996-997), to visualize habit and crystal behaviour within an MSMPR crystallizer. A comparison of the steady-state crystal size distributions measured by low angle light scattering (LALLS) and FBRM was made, showing poor sensitivity of the FBRM technique to particles of less than 1 μm hence the technique was not suitable for the measurement of crystallization kinetics for this organic system.

  18. Volumetric thermal measurements using thermo-liquid crystal (TLC) micro-particles in evaporating drops

    Science.gov (United States)

    Segura, Rodrigo; Marin, Alvaro Gomez; Kaehler, Christian

    2013-11-01

    Freely evaporating sessile droplets develop weak temperature gradients that can generate Marangoni flows at the drop's surface. Quantitative temperature measurements of small gradients at such scales are very difficult. In this work, a method to track the temperature of individual thermo-liquid crystal (TLC) particles is employed to extract the temperature field inside an evaporating droplet. TLC thermography has been investigated for several years but the low quality of individual TLC particles, as well as the methods used to extract temperature from their color appearance, has prevented the development of a reliable approach to track their temperature individually. In order to overcome these challenges, an emulsion of stable non-encapsulated TLC micro particles with a narrower size distribution than that of commercial encapsulated TLC solutions was used along with a multi-variable calibration approach, as opposed to the direct hue-temperature relationship usually implemented (Segura et al., Microfluid Nanofluid, 2012). In addition, an optimized color space was implemented as well as circular polarization filtering to remove background noise and improve signal-to-noise ratio. Using this technique, a 3D temperature-velocity field within a droplet could be simultaneously resolved.

  19. Charge generation measured for fullerene-helical nanofilament liquid crystal heterojunctions.

    Science.gov (United States)

    Callahan, Rebecca A; Coffey, David C; Chen, Dong; Clark, Noel A; Rumbles, Garry; Walba, David M

    2014-04-01

    The helical nanofilament (HNF) liquid crystal phase is an ordered architecture exhibiting interesting properties for charge transport. It is a small molecule self-assembly of stacked and twisted crystalline layers, which form alignable organic nanorods with half the surface area of the filaments consisting of aromatic sublayer edges. HNFs mixed with an electron acceptor generate an intriguing network for photoinduced electron transfer (PET). In this work, we characterize the structure of the HNF phase as processed into thin films with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Additionally, we measure the flash-photolysis time-resolved microwave conductivity (TRMC) in samples where the HNF phase is fabricated into heterojunctions with the fullerenes C60 and PC60BM, prototypical electron acceptors for organic photovoltaics. Two distinct microstructures of the thin films were identified and compared for PET. A near-unity charge generation yield is observed in a bilayer of HNFs with C60. Moreover, the HNF phase is shown to be 10× better at charge generation than a lamellar structuring of the same components. Thus, the HNF phase is shown to be a good charge-generation interface.

  20. A crystal detector for measuring beta and internal conversion electrons in flowing air containing fission gases

    Science.gov (United States)

    Schell, W. R.; Vives-Batlle, J.; Yoon, S. R.; Tobin, M. J.

    1999-02-01

    Low levels of radioactive gases are released from nuclear electric power generation, nuclear fuel reprocessing plants, nuclear weapons tests and from diagnostic medical uses of radioactive gas tracers. A prototype model of an inorganic scintillator - Crystal Gas Electron Detector (CGED) - was built for measurements of xenon isotopes in-line by detecting the beta and internal conversion (IC) electrons present in atmospheric samples. The detection and quantification of the radionuclide spectra are accomplished, during air flow, without complete purification of the fission gases. Initial operational tests and calibrations made permit the integration of the CGED into a portable Gas Analysis, Separation and Purification (GASP) system [1-3]. The CGED detector, Pulse Shaping and Timing (PSA) electronics, and mathematical treatment of the accumulated spectra are used to resolve the K and LMNO-IC electrons and beta continuum. These data are used, in-line, for dating the age of an air parcel containing fission gases released from nuclear reactors and/or from nuclear weapons tests, as part of the monitoring equipment required to enforce the Comprehensive Test Ban Treaty, CTBT. This report is one of a series of papers providing the design features, operational methods, calibration, and applications of radioactive gas analysis system to the International CTBT.

  1. Measuring the Photocatalytic Breakdown of Crystal Violet Dye using a Light Emitting Diode Approach

    Science.gov (United States)

    Ryan, Robert E.; Underwood, Lauren W.; O'Neal, Duane; Pagnutti, Mary; Davis, Bruce A.

    2009-01-01

    A simple method to estimate the photocatalytic reactivity performance of spray-on titanium dioxide coatings for transmissive glass surfaces was developed. This novel technique provides a standardized method to evaluate the efficiency of photocatalytic material systems over a variety of illumination levels. To date, photocatalysis assessments have generally been conducted using mercury black light lamps. Illumination levels for these types of lamps are difficult to vary, consequently limiting their use for assessing material performance under a diverse range of simulated environmental conditions. This new technique uses an ultraviolet (UV) gallium nitride (GaN) light emitting diode (LED) array instead of a traditional black light to initiate and sustain photocatalytic breakdown. This method was tested with a UV-resistant dye (crystal violet) applied to a titanium dioxide coated glass slide. Experimental control is accomplished by applying crystal violet to both titanium dioxide coated slides and uncoated control slides. A slide is illuminated by the UV LED array, at various light levels representative of outdoor and indoor conditions, from the dye side of the slide. To monitor degradation of the dye over time, a temperature-stabilized white light LED, whose emission spectrum overlaps with the dye absorption spectrum, is used to illuminate the opposite side of the slide. Using a spectrometer, the amount of light from the white light LED transmitted through the slide as the dye degrades is monitored as a function of wavelength and time and is subsequently analyzed. In this way, the rate of degradation for photocatalytically coated versus uncoated slide surfaces can be compared. Results demonstrate that the dye absorption decreased much more rapidly on the photocatalytically coated slides than on the control uncoated slides, and that dye degradation is dependent on illumination level. For photocatalytic activity assessment purposes, this experimental configuration and

  2. Upgrades of poloidal and tangential x-ray imaging crystal spectrometers for temperature and rotation measurements on EAST

    Science.gov (United States)

    Wang, Fudi; Chen, Jun; Hu, Ruiji; Lyu, Bo; Colledani, Gilles; Fu, Jia; Li, Yingying; Bitter, Manfred; Hill, Kenneth; Lee, Sangon; Ye, Minyou; Shi, Yuejiang; Wan, Baonian

    2016-11-01

    During the past two years, key parts of poloidal and tangential x-ray imaging crystal spectrometers (PXCSs and TXCSs) have been upgraded. For poloidal XCSs, double-crystals of ArXVII and FeXXV were deployed. For fulfilling in situ alignment of a poloidal XCS, the beryllium window must be flexibly removed. By utilizing a design, where the beryllium window was installed in the vacuum chamber of the double-crystal, and between the double-crystal and wall of this chamber, an in situ alignment for the two spectrometers was fulfilled. Also, a new holder for the double-crystal was installed to allow for precise adjustments of azimuth angle and vertical height of the double-crystal. In order to facilitate these adjustments of double-crystal and installation of beryllium window, the chamber of the double-crystal for PXCS was upgraded from a cylinder to a cuboid. The distance between double-crystal and magnetic axis was extended from 8936 mm to 9850 mm in order to improve spatial resolution for PXCS, which is currently in the range from 1.237 mm to 4.80 mm at magnetic axis. Furthermore, a new pixelated detector (PILATUS 900K), which has a large sensitive area of 83.8 × 325.3 mm2 and which is vacuum compatible, is being implemented on the PXCS. This detector is mounted on a rail, so that its position can be changed by 50 mm to effectively record spectra of He-like argon and He-like iron (ArXVII and FeXXV). Similarly, a rail, which allows detector movement by 50 mm, was also installed in TXCS to alternatively record spectra of ArXVII and ArXVIII. Presently, the operation duration of PXCS and TXCS has been upgraded to hundreds of seconds in one shot. Ti- and uϕ-profiles measured by TXCS and charge exchange recombination spectroscopy (CXRS) were compared and found to be in good agreement.

  3. Remote sensing of ice crystal asymmetry parameter using multi-directional polarization measurements – Part 1: Methodology and evaluation with simulated measurements

    Directory of Open Access Journals (Sweden)

    P. Yang

    2012-10-01

    Full Text Available We present a new remote sensing technique to infer the average asymmetry parameter of ice crystals near cloud top from multi-directional polarization measurements. The method is based on previous findings that (a complex aggregates of hexagonal crystals generally have scattering phase matrices resembling those of their components; and (b scattering phase matrices systematically vary with aspect ratios of crystals and their degree of microscale surface roughness. Ice cloud asymmetry parameters are inferred from multi-directional polarized reflectance measurements by searching for the closest fit in a look-up table of simulated polarized reflectances computed for cloud layers that contain individual, randomly oriented hexagonal columns and plates with varying aspect ratios and roughness values. The asymmetry parameter of the hexagonal particle that leads to the best fit with the measurements is considered the retrieved value. For clouds with optical thickness less than 5, the cloud optical thickness must be retrieved simultaneously with the asymmetry parameter, while for optically thicker clouds the asymmetry parameter retrieval is independent of cloud optical thickness. Evaluation of the technique using simulated measurements based on the optical properties of a number of complex particles and their mixtures shows that the ice crystal asymmetry parameters are generally retrieved to within 5%, or about 0.04 in absolute terms. The retrieval scheme is largely independent of calibration errors, range and sampling density of scattering angles and random noise in the measurements. The approach can be applied to measurements of past, current and future airborne and satellite instruments that measure multi-directional polarized reflectances of ice-topped clouds.

  4. Remote sensing of ice crystal asymmetry parameter using multi-directional polarization measurements – Part 1: Methodology and evaluation with simulated measurements

    Directory of Open Access Journals (Sweden)

    B. van Diedenhoven

    2012-06-01

    Full Text Available We present a new remote sensing technique to infer the average asymmetry parameter of ice crystals near cloud top from multi-directional polarization measurements. The method is based on previous findings that (a complex aggregates of hexagonal crystals generally have scattering phase matrices resembling those of their components and (b scattering phase matrices systematically vary with aspect ratios of crystals and their degree of microscale surface roughness. Ice cloud asymmetry parameters are inferred from multi-directional polarized reflectance measurements by searching for the closest fit in a look-up table of simulated polarized reflectances computed for cloud layers that contain individual hexagonal columns and plates with varying aspect ratios and roughness values. The asymmetry parameter of the hexagonal particle that leads to the best fit with the measurements is considered the retrieved value. For clouds with optical thickness less than 5, the cloud optical thickness must be retrieved simultaneously with the asymmetry parameter, while for optically thicker clouds the asymmetry parameter retrieval is independent of cloud optical thickness. Evaluation of the technique using simulated measurements based on the optical properties of a number of complex particles and their mixtures shows that the ice crystal asymmetry parameters are generally retrieved to within 5%, or about 0.04 in absolute terms. The retrieval scheme is largely independent of calibration errors, range and sampling density of scattering angles and random noise in the measurements. The approach can be readily applied to measurements of past, current and future airborne and satellite instruments that measure multi-directional polarized reflectances of ice-topped clouds.

  5. Photonic crystal fibre as an optofluidic reactor for the measurement of photochemical kinetics with sub-picomole sensitivity.

    Science.gov (United States)

    Williams, Gareth O S; Chen, Jocelyn S Y; Euser, Tijmen G; Russell, Philip St J; Jones, Anita C

    2012-09-21

    Photonic crystal fibre constitutes an optofluidic system in which light can be efficiently coupled into a solution-phase sample, contained within the hollow core of the fibre, over long path-lengths. This provides an ideal arrangement for the highly sensitive monitoring of photochemical reactions by absorption spectroscopy. We report here the use of UV/vis spectroscopy to measure the kinetics of the photochemical and thermal cis-trans isomerisation of sub-picomole samples of two azo dyes within the 19-μm diameter core of a photonic crystal fibre, over a path length of 30 cm. Photoisomerisation quantum yields are the first reported for "push-pull" azobenzenes in solution at room temperature; such measurements are challenging because of the fast thermal isomerisation process. Rate constants obtained for thermal isomerisation are in excellent agreement with those established previously in conventional cuvette-based measurements. The high sensitivity afforded by this intra-fibre method enables measurements in solvents in which the dyes are too insoluble to permit conventional cuvette-based measurements. The results presented demonstrate the potential of photonic crystal fibres as optofluidic elements in lab-on-a-chip devices for photochemical applications.

  6. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2003-04-01

    This report summarizes technical progress over the first six months of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on analyzing and testing factors that impact performance degradation of the initially designed sensor prototype, including sensing element movement within the sensing probe and optical signal quality degradation. Based these results, a new version of the sensing system was designed by combining the sapphire disk sensing element and the single crystal zirconia right angle light reflector into one novel single crystal sapphire right angle prism. The new sensor prototype was tested up to 1650 C.

  7. An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

    Science.gov (United States)

    Ryan, Robert E.; Underwood, Lauren W.; ONeal, Duane; Pagnutti, Mary; Davis, Bruce A.

    2009-01-01

    A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor

  8. Measurement of anchoring coefficient of homeotropically aligned nematic liquid crystal using a polarizing optical microscope in reflective mode

    Directory of Open Access Journals (Sweden)

    Sang-In Baek

    2015-09-01

    Full Text Available Although the homeotropic alignment of liquid crystals is widely used in LCD TVs, no easy method exists to measure its anchoring coefficient. In this study, we propose an easy and convenient measurement technique in which a polarizing optical microscope is used in the reflective mode with an objective lens having a low depth of focus. All measurements focus on the reflection of light near the interface between the liquid crystal and alignment layer. The change in the reflected light is measured by applying an electric field. We model the response of the director of the liquid crystal to the electric field and, thus, the change in reflectance. By adjusting the extrapolation length in the calculation, we match the experimental and calculated results and obtain the anchoring coefficient. In our experiment, the extrapolation lengths were 0.31 ± 0.04 μm, 0.32 ± 0.08 μm, and 0.23 ± 0.05 μm for lecithin, AL-64168, and SE-5662, respectively.

  9. Retrieval of ice crystals' mass from ice water content and particle distribution measurements: a numerical optimization approach

    Science.gov (United States)

    Coutris, Pierre; Leroy, Delphine; Fontaine, Emmanuel; Schwarzenboeck, Alfons; Strapp, J. Walter

    2016-04-01

    A new method to retrieve cloud water content from in-situ measured 2D particle images from optical array probes (OAP) is presented. With the overall objective to build a statistical model of crystals' mass as a function of their size, environmental temperature and crystal microphysical history, this study presents the methodology to retrieve the mass of crystals sorted by size from 2D images using a numerical optimization approach. The methodology is validated using two datasets of in-situ measurements gathered during two airborne field campaigns held in Darwin, Australia (2014), and Cayenne, France (2015), in the frame of the High Altitude Ice Crystals (HAIC) / High Ice Water Content (HIWC) projects. During these campaigns, a Falcon F-20 research aircraft equipped with state-of-the art microphysical instrumentation sampled numerous mesoscale convective systems (MCS) in order to study dynamical and microphysical properties and processes of high ice water content areas. Experimentally, an isokinetic evaporator probe, referred to as IKP-2, provides a reference measurement of the total water content (TWC) which equals ice water content, (IWC) when (supercooled) liquid water is absent. Two optical array probes, namely 2D-S and PIP, produce 2D images of individual crystals ranging from 50 μm to 12840 μm from which particle size distributions (PSD) are derived. Mathematically, the problem is formulated as an inverse problem in which the crystals' mass is assumed constant over a size class and is computed for each size class from IWC and PSD data: PSD.m = IW C This problem is solved using numerical optimization technique in which an objective function is minimized. The objective function is defined as follows: 2 J(m)=∥P SD.m - IW C ∥ + λ.R (m) where the regularization parameter λ and the regularization function R(m) are tuned based on data characteristics. The method is implemented in two steps. First, the method is developed on synthetic crystal populations in

  10. Direct observation of phase transitions: in situ diffraction measurements at the crystal scale

    Science.gov (United States)

    Bernier, J. V.; Barton, N. R.; Farber, D.; Wenk, H.; Kunz, M.; Lienert, U.

    2012-12-01

    Phase transitions often display determinate crystallographic orientation relationships between parent and symmetrically degenerate daughter domains. Preferred variant selection and orientation memory under the influence of deviatoric stress are the 'fingerprints' of the transformation mechanism, driving force, and microstructure. For the α-ɛ transition in iron - significant to the structure and anisotropy of the Earth's inner core - these have been studied primarily by texture analysis of polycrystalline powders; the convoluted nature of these data, however, render it essentially impossible to examine variant selection, and even precise orientation relationships themselves. Recently developed X-ray diffraction techniques have made it possible to answer these questions. Results from two measurements are presented. First, heterogeneous variant selection was observed and the specific α/ɛ orientation relationship was determined under quasi-static loading using High Energy Diffraction Microscopy at beamline 1-ID of APS-ANL. Second, the spatial heterogeneity and mutual exclusivity among ɛ variants was observed at the incipient transition using the Laue μ-diffraction technique at beamline 12.3.2. of ALS-LBNL. In both cases, a 60x25μm single crystal of iron was pressurized in a DAC and measured before and after the α-ɛ transition at 13GPa. In the HEDM experiment, spatial resolution is sacrificed for domain-averaged orientation and strain resoltuion, making it possible to quantify the magnitude of the applied deviatoric stress in situ. In the Laue μ-Diffraction technique, the local lattice orientations are mapped with 1μm resolution, displaying marked spatial variation. These pilot experiments open new possibilities for investigating high pressure/high temperature transformations in situ. By mapping both orientations and lattice strains, the nature of the mechanisms and driving forces can be illuminated. This work was performed under the auspices of the U

  11. Particle Size Measurements from the first Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

    Science.gov (United States)

    King, Michael C.; Bachalo, William; Kurek, Andrzej

    2017-01-01

    This presentation shows particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

  12. Performance of a compact multi-crystal high-purity germanium detector array for measuring coincident gamma-ray emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris; Daigle, Stephen; Buckner, Matt [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Erikson, Luke E.; Runkle, Robert C. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Stave, Sean C., E-mail: Sean.Stave@pnnl.gov [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Champagne, Arthur E.; Cooper, Andrew; Downen, Lori [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States); Glasgow, Brian D. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Kelly, Keegan; Sallaska, Anne [University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708 (United States)

    2015-05-21

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the {sup 14}N(p,γ){sup 15}O{sup ⁎} reaction for several transition energies at an effective center-of-mass energy of 163 keV. Owing to the granular nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within their uncertainties with the past measurements. Details of the analysis and detector performance are presented.

  13. Performance of A Compact Multi-crystal High-purity Germanium Detector Array for Measuring Coincident Gamma-ray Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Chris [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Daigle, Stephen [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Buckner, Matt [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Erikson, Luke E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Runkle, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stave, Sean C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Champagne, Art [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Cooper, Andrew [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Downen, Lori [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Glasgow, Brian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kelly, Keegan [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States); Sallaska, Anne [Univ. of North Carolina, Chapel Hill, NC (United States); Triangle Univ. Nuclear Lab., Durham, NC (United States)

    2015-02-18

    The Multi-sensor Airborne Radiation Survey (MARS) detector is a 14-crystal array of high-purity germanium (HPGe) detectors housed in a single cryostat. The array was used to measure the astrophysical S-factor for the 14N(p,γ)15O* reaction for several transition energies at an effective center of mass energy of 163 keV. Owing to the segmented nature of the MARS detector, the effect of gamma-ray summing was greatly reduced in comparison to past experiments which utilized large, single-crystal detectors. The new S-factor values agree within the uncertainties with the past measurements. Details of the analysis and detector performance will be presented.

  14. Time-Domain Measurement of Optical True-Time Delay in Two-Dimensional Photonic Crystal Waveguides

    Institute of Scientific and Technical Information of China (English)

    ZHANG Geng-Yan; ZHOU Qiang; CUI Kai-Yu; ZHANG Wei; HUANG Yi-Dong

    2010-01-01

    @@ We report on the realization of optical true-time delay(TTD)by a two-dimensional photonic crystal waveguide(PCWG).Design and fabrication of the PCWG are investigated.The spectral dependence of the group delay is measured by detecting the phase shifts of a 10 GHz modulating signal,and a maximum delay of 25 ± 2.5 ps is obtained.

  15. Electrical Resistance Measurement of Glass Transition and Crystallization Characteristics of Zr-Al-Cu-Ni Metallic Glasses

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In this paper, glass transition and thermal stability of the Zr-Al-Cu-Ni metallic glasses were investigated by using electrical resistance measurement (ERM), DSC and X-ray diffraction techniques. The experimental results show that the ERM is capable of detecting the glass transition of the amorphous alloys and can help to distinguish the crystallization products of the Zr-Al-Cu-Ni metallic glasses owing to the difference of the electrical resistivity between the precipitation phases.

  16. Spatially Resolved Spectra from a new X-ray Imaging Crystal Spectrometer for Measurements of Ion and Electron Temperature Profiles

    Energy Technology Data Exchange (ETDEWEB)

    Bitter, M; Stratton, B; Roquemore, A; Mastrovito, D; Lee, S; Bak, J; Moon, M; Nam, U; Smith, G; Rice, J; Beiersdorfer, P; Fraenkel, B

    2004-08-10

    A new type of high-resolution X-ray imaging crystal spectrometer is being developed to measure ion and electron temperature profiles in tokamak plasmas. The instrument is particularly valuable for diagnosing plasmas with purely Ohmic heating and rf heating, since it does not require the injection of a neutral beam - although it can also be used for the diagnosis of neutral-beam heated plasmas. The spectrometer consists of a spherically bent quartz crystal and a two-dimensional position-sensitive detector. It records spectra of helium-like argon (or krypton) from multiple sightlines through the plasma and projects a de-magnified image of a large plasma cross-section onto the detector. The spatial resolution in the plasma is solely determined by the height of the crystal, its radius of curvature, and the Bragg angle. This new X-ray imaging crystal spectrometer may also be of interest for the diagnosis of ion temperature profiles in future large tokamaks, such as KSTAR and ITER, where the application of the presently used charge-exchange spectroscopy will be difficult, if the neutral beams do not penetrate to the plasma center. The paper presents the results from proof-of-principle experiments performed with a prototype instrument at Alcator C-Mod.

  17. Dynamics of mineral crystallization from precipitated slab-derived fluid phase: first in situ synchrotron X-ray measurements

    Science.gov (United States)

    Malaspina, Nadia; Alvaro, Matteo; Campione, Marcello; Wilhelm, Heribert; Nestola, Fabrizio

    2015-03-01

    Remnants of the fluid phase at ultrahigh pressure (UHP) in subduction environments may be preserved as primary multiphase inclusions in UHP minerals. The mode of crystallization of daughter minerals during precipitation within the inclusion and/or the mechanism of interaction between the fluid at supercritical conditions and the host mineral are still poorly understood from a crystallographic point of view. A case study is represented by garnet-orthopyroxenites from the Maowu Ultramafic Complex (China) deriving from harzburgite precursors metasomatized at ~4 GPa, 750 °C by a silica- and incompatible trace element-rich fluid phase. This metasomatism produced poikilitic orthopyroxene and inclusion-rich garnet porphyroblasts. Solid multiphase primary inclusions in garnet display a size within a few tens of micrometres and negative crystal shapes. Infilling minerals (spinel: 10-20 vol%; amphibole, chlorite, talc, mica: 80-90 vol%) occur with constant volume proportions and derive from trapped solute-rich aqueous fluids. To constrain the possible mode of precipitation of daughter minerals, we performed for the first time a single-crystal X-ray diffraction experiment by synchrotron radiation at Diamond Light Source. In combination with electron probe microanalyses, this measurement allowed the unique identification of each mineral phase and reciprocal orientations. We demonstrated the epitaxial relationship between spinel and garnet and between some hydrous minerals. Such information is discussed in relation to the physico-chemical aspects of nucleation and growth, shedding light on the mode of mineral crystallization from a fluid phase trapped at supercritical conditions.

  18. Real-time, high-resolution x-ray diffraction measurements on shocked crystals at a synchrotron facility.

    Science.gov (United States)

    Gupta, Y M; Turneaure, Stefan J; Perkins, K; Zimmerman, K; Arganbright, N; Shen, G; Chow, P

    2012-12-01

    The Advanced Photon Source (APS) at Argonne National Laboratory was used to obtain real-time, high-resolution x-ray diffraction measurements to determine the microscopic response of shock-compressed single crystals. Disk shaped samples were subjected to plane shock wave compression by impacting them with half-inch diameter, flat-faced projectiles. The projectiles were accelerated to velocities ranging between 300 and 1200 m/s using a compact powder gun designed specifically for use at a synchrotron facility. The experiments were designed to keep the sample probed volume under uniaxial strain and constant stress for a duration longer than the 153.4 ns spacing between x-ray bunches. X-rays from a single pulse (crystals at the APS are presented. Analytic developments to determine the effects of crystal substructure and non-ideal geometry on the diffraction pattern position and shape are presented. Representative real-time x-ray diffraction data, indicating shock-induced microstructural changes, are presented for a shock-compressed Al(111) sample. The experimental developments presented here provided, in part, the impetus for the Dynamic Compression Sector (DCS) currently under development at the APS. Both the synchronization∕x-ray detection methods and the analysis equations for high-resolution single crystal x-ray diffraction can be used at the DCS.

  19. Measurements of Pair Production Under Channelling Conditions by 70-180 GeV Photons Incident on Single Crystals

    CERN Multimedia

    2002-01-01

    This experiment will use the WA69 set-up to deliver a tagged photon beam in the energy range from 15~GeV to 150~GeV with a total angular spread of about @M~0.5~mrad. The incident photon direction is known to about 35~@mrad through the direction of the emitting electron. The photon beam is incident on an about 1~mm thick Ge single crystal in order to investigate pair production in single crystals. Above a certain energy threshold photons incident along crystal axis will show strongly increased pair production yi - the so-called .us Channelling Pair Production (ChPP). The produced pairs are analyzed in the @W-spectrometer. The large spread in incident photon angles offers an excellent opportunity to investigate in one single experiment the pair production in an angular region around a crystal axes and thereby compare ChPP with coherent (CPP) and incoherent (ICPP) processes. The very abrupt onset of ChPP (around threshold) will be measured and give a crucial test of the theoretical calculations. The differential...

  20. Measurement of X-ray beam emittance using crystal optics at an X-ray undulator beamline

    CERN Document Server

    Kohmura, Y; Awaji, M; Tanaka, T; Hara, T; Goto, S; Ishikawa, T

    2000-01-01

    We present a method of using crystal optics to measure the emittance of the X-ray source. Two perfect crystals set in (++) configuration work as a high-resolution collimator. The phase-space diagram (i.e. beam cross-section and angular distribution) could be determined without any assumptions on the light source. When the measurement is done at short wavelength radiation from undulator, the electron beam emittance is larger than the diffraction limit of the X-rays. Therefore, the electron beam emittance could be estimated. The measurement was done with the hard X-rays of 18.5 and 55 keV from an undulator beamline, BL 47XU, of SPring-8. The horizontal emittance of the X-ray beam was estimated to be about 7.6 nmrad, close to the designed electron beam emittance of the storage ring (7 nmrad). Some portions of the instrumental functions, such as the scattering by filters and windows along the beamline and the slight bent of the crystal planes of the monochromator, could not be precisely evaluated, but an upper li...

  1. Refractive Index Measurement within a Photonic Crystal Fibre Based on Short Wavelength Diffraction

    Directory of Open Access Journals (Sweden)

    Nathaniel Groothoff

    2007-10-01

    Full Text Available A new class of refractive index sensors using solid core photonic crystal fibres isdemonstrated. Coherent scattering at the cladding lattice is used to optically characterizematerials inserted into the fibre holes. The liquid to solid phase transition of water uponfreezing to ice 1h is characterized by determining the refractive index.

  2. Accurate wavelength prediction of photonic crystal resonant reflection and applications in refractive index measurement

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron L. C.

    2014-01-01

    In the past decade, photonic crystal resonant reflectors have been increasingly used as the basis for label-free biochemical assays in lab-on-a-chip applications. In both designing and interpreting experimental results, an accurate model describing the optical behavior of such structures is essen...

  3. Thick monolithic scintillation crystals for TOF-PET with depth-of-interaction measurement

    NARCIS (Netherlands)

    Vinke, Ruud; van Dam, Herman T.; Seifert, Stefan; Beekman, Freek J.; Lohner, Herbert; Schaart, Dennis R.; Dendooven, Peter

    2010-01-01

    Positron emission tomography (PET) detectors based on monolithic scintillation crystals show excellent intrinsic spatial resolution and allow depth-of-interaction (DOI) reconstruction using a single photosensor array. The inclusion of time-of-flight (TOF) information in the image reconstruction

  4. Microindentation deformation of lithium dihydrogen phosphate single crystals: Microhardness measurement and indentation size effect

    Energy Technology Data Exchange (ETDEWEB)

    Iurchenko, Anton [Institute for Single Crystals, National Academy of Sciences of Ukraine, Lenin Avenue 60, 61001 Kharkiv (Ukraine); Borc, Jarosław, E-mail: j.borc@pollub.pl [Department of Applied Physics, Lublin University of Technology, ul. Nadbystrzycka 38, 20-618 Lublin (Poland); Sangwal, Keshra [Department of Applied Physics, Lublin University of Technology, ul. Nadbystrzycka 38, 20-618 Lublin (Poland); Voronov, Alexei [Institute for Single Crystals, National Academy of Sciences of Ukraine, Lenin Avenue 60, 61001 Kharkiv (Ukraine)

    2016-02-15

    The Vickers microhardness H{sub V} of the (110) and (111) as-grown faces of lithium dihydrogen phosphate (LDP) crystals was investigated as a function of applied load P. The microhardness H{sub V} of the two faces increases with load P i.e. reverse indentation size effect (reverse ISE) and the hardness of the (110) face is somewhat lower than that of the (111) face but this difference is not easily recognized for these planes due to large scatter in the data. The origin of observed ISE was analyzed using different approaches. It was found that: (1) Hays–Kendall's and Begley–Hutchinson's relations do not explain the origin of reverse ISE but Meyer's law describes the reverse ISE satisfactorily and its constants provide a link between ISE and formation of radial cracks with applied indentation load P, (2) reverse ISE is associated with tensile surface stresses, (3) despite its failure to explain reverse ISE, Begley–Hutchinson's relation is reliable to obtain load-independent hardness H{sub 0}, is 2337 MPa for LDP, and (4) the value of fracture toughness K{sub C} of LDP crystals lies between 4.7 and 12 MPa m{sup 1/2}. The load-independent hardness H{sub 0} of LDP is higher by a factor of 1.5 than that reported for undoped KDP and ADP crystals whereas its fracture toughness K{sub C} is higher by factor of about 20 than that of undoped KDP crystals. - Highlights: • Vickers indentations on the (110) and (111) faces of LDP crystals were made. • The microhardness H{sub V} was investigated as a function of applied load P. • Reverse indentation size effect was observed. • Fracture toughness K{sub C} from the radial cracks was calculated.

  5. Measurement of the Third-Order Nonlinear Optical Coefficient of ZnO Crystals by Using ICCD-Z-Scan

    Institute of Scientific and Technical Information of China (English)

    JIA Guang-Ming; ZHANG Gui-Zhong; XIANG Wang-Hua; J.B.Ketterson

    2004-01-01

    We present an image-intensified charge-coupled-device (ICCD) version of Z-scan by employing an ICCD detector and fixing the sample at the beam waist, and a measurement of the third-order nonlinear optical coefficient of single crystal zinc oxide (ZnO). The X(3) value of -9.1 × 10-15 cm2/W measured is in agreement with the published result. Our Z-scan configuration of placing sample at beam waist and collecting the whole wavefront by an ICCD detector is simple and can be deployed in cryogenic research where the sample cannot be Z-scanned.

  6. Configurational coordinate diagram of Ni{sup 2+} doped silver halide crystals, as determined by optical and luminescence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zakosky-Neuberger, I., E-mail: yifat_z2@hotmail.com [Raymond and Beverly Sackler Faculty of Exact Sciences, School of Physics and Astronomy, Tel-Aviv University, Tel-Aviv 69978 (Israel); Shafir, I.; Nagli, L.; Katzir, A. [Raymond and Beverly Sackler Faculty of Exact Sciences, School of Physics and Astronomy, Tel-Aviv University, Tel-Aviv 69978 (Israel)

    2012-08-15

    Optical and luminescence measurements were carried out on Ni{sup 2+} doped silver halide crystals. The configurational coordinates of the ground and the first excited states made it possible to explain the important optical properties, such as the Stokes shift between the ground and excited states, the broadening of the bands with temperature and the thermal quenching. Determining the configurational coordinate diagram of the ground and first excited states is the first step for the design and fabrication of solid state and fiber lasers which are based on Ni{sup 2+} doped silver halides and which operate in the middle infrared. - Highlights: Black-Right-Pointing-Pointer Optical and luminescence measurements were carried out on Ni{sup 2+} doped silver halide crystals. Black-Right-Pointing-Pointer Configurational coordinates of the ground and the first excited state were calculated. Black-Right-Pointing-Pointer Optical properties of Ni{sup 2+} doped silver halide crystals can be obtained from the configurational coordinate diagram. Black-Right-Pointing-Pointer No emission signal was found above 220 K.

  7. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2003-11-01

    This report summarizes technical progress over the second six month period of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on evaluating corrosion effects in single crystal sapphire at temperatures up to 1400 C, and designing the sensor mechanical packaging with input from Wabash River Power Plant. Upcoming meetings will establish details for the gasifier field test.

  8. Direct investigations on strain-induced cold crystallization behavior and structure evolutions in amorphous poly(lactic acid) with SAXS and WAXS measurements

    DEFF Research Database (Denmark)

    Zhou, Chengbo; Li, Hongfei; Zhang, Wenyang

    2016-01-01

    Strain-induced cold crystallization behavior and structure evolution of amorphous poly(lactic acid) (PLA) stretched within 70-90 degrees C were investigated via in situ synchrotron small-angle X-ray scattering (SAXS) and wide-angle X-ray scattering (WAXS) measurements as well as differential...... first then forms crystal with strain increasing. The stacked structure consisting of less perfect crystalline phase, mesocrystal and oriented amorphous phase emerges at the final stage of stretching. Drawing at 80 degrees C, only the crystal can be induced at lower strain with higher crystallization...... in strain-induced crystallization behavior of amorphous PLA within 70-90 degrees C can be attributed to the competition between chain orientation caused by stretching and chain relaxation. It was proposed that the strain-induced mesocrystal/crystal and the lamellae are formed from the mesophase originally...

  9. Measurement of Peltier Heat at the Solid/Liquid Interface and Its Application to Crystal Growth I : Theoretical Approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.H. [Chungju National University, Chungju (Korea); Jang, K.W. [Hanseo University,Seosan (Korea); Lee, D.H. [Yonsei University, Seoul (Korea)

    1999-11-01

    The Peltier heat absorbed or evolved at the solid/liquid interface in the unidirectional solidification process could contribute to the increase of temperature gradient in liquid and growth velocity, and the enhancement of crystal orientation. In this study, in order to measure the Peltier heat generated at the solid/liquid interface as a way of application to crystal growth, the thermoelectric effects were investigated on the temperature changes at the solid-and liquid-phase of the same material and its interface. Through the theoretical consideration, it was possible to separate sole Peltier, Thomson or Joule heat from the temperature changes due to current density, polarity, and temperature gradient. Thomson coefficient of solid- and liquid-phase as well as Peltier coefficient at the solid/liquid interface could be obtained. (author). 10 refs., 3 figs.

  10. Study on measurement accuracy of active optics null test systems based on liquid crystal spatial light modulator and laser interferometer

    Science.gov (United States)

    Liu, Shijie; Xu, Longbo; Ma, Xiao; Zhang, Zhigang; Zhou, You; Lu, Qi; Bai, Yunbo; Shao, Jianda

    2017-06-01

    A common way to test high-quality aspherical lenses is to use a measurement system based on a set of null corrector and a laser interferometer. The null corrector can either be a combination of spherical lenses or be a computer generated hologram (CGH), which compensates the aspheric wave-front being tested. However, the null optics can't be repeatedly used once the shape of tested optics changes. Alternative active null correctors have been proposed based on dynamic phase modulator devices. A typical dynamic phase modulator is liquid crystal spatial light modulator (LCSLM), which can spatially change the refractive index of the liquid crystal and thus modify the phase of the input wave-front. Even though the measurement method based on LCSLM and laser interferometer has been proposed and demonstrated for optical testing several years ago, it still can't be used in the high quality measurement process due to its limited accuracy. In this paper, we systematically study the factors such as LCSLM structure parameters, encoding error and laser interferometer performance, which significantly affect the measurement accuracy. Some solutions will be proposed in order to improve the measurement accuracy based on LCSLM and laser interferometer.

  11. Heterodyne pump probe measurements of nonlinear dynamics in an indium phosphide photonic crystal cavity

    DEFF Research Database (Denmark)

    Heuck, Mikkel; Combrié, S.; Lehoucq, G.

    2013-01-01

    Using a sensitive two-color heterodyne pump-probe technique, we investigate the carrier dynamics of an InP photonic crystal nanocavity. The heterodyne technique provides unambiguous results for all wavelength configurations, including the degenerate case, which cannot be investigated with the wid...... with the widely used homodyne technique. A model based on coupled mode theory including two carrier distributions is introduced to account for the relaxation dynamics, which is assumed to be governed by both diffusion and recombination.......Using a sensitive two-color heterodyne pump-probe technique, we investigate the carrier dynamics of an InP photonic crystal nanocavity. The heterodyne technique provides unambiguous results for all wavelength configurations, including the degenerate case, which cannot be investigated...

  12. A miniature system for separating aerosol particles and measuring mass concentrations.

    Science.gov (United States)

    Liang, Dao; Shih, Wen-Pin; Chen, Chuin-Shan; Dai, Chi-An

    2010-01-01

    We designed and fabricated a new sensing system which consists of two virtual impactors and two quartz-crystal microbalance (QCM) sensors for measuring particle mass concentration and size distribution. The virtual impactors utilized different inertial forces of particles in air flow to classify different particle sizes. They were designed to classify particle diameter, d, into three different ranges: d3.20 μm. The QCM sensors were coated with a hydrogel, which was found to be a reliable adhesive for capturing aerosol particles. The QCM sensor coated with hydrogel was used to measure the mass loading of particles by utilizing its characteristic of resonant frequency shift. An integrated system has been demonstrated.

  13. A Miniature System for Separating Aerosol Particles and Measuring Mass Concentrations

    Directory of Open Access Journals (Sweden)

    Dao Liang

    2010-04-01

    Full Text Available We designed and fabricated a new sensing system which consists of two virtual impactors and two quartz-crystal microbalance (QCM sensors for measuring particle mass concentration and size distribution. The virtual impactors utilized different inertial forces of particles in air flow to classify different particle sizes. They were designed to classify particle diameter, d, into three different ranges: d < 2.28 μm, 2.28 μm ≤ d ≤ 3.20 μm, d > 3.20 μm. The QCM sensors were coated with a hydrogel, which was found to be a reliable adhesive for capturing aerosol particles. The QCM sensor coated with hydrogel was used to measure the mass loading of particles by utilizing its characteristic of resonant frequency shift. An integrated system has been demonstrated.

  14. Identification of the crystallization kinetic parameters of a semi-crystalline polymer by using PVTα measurement

    Science.gov (United States)

    Tardif, X.; Sobotka, V.; Boyard, N.; Delaunay, D.

    2011-05-01

    Injection molding is the most widely used process in the plastic industry. In the case of semi-crystalline polymer, crystallization kinetics impacts directly the quality of the piece, both on dimensional and mechanical aspects. The characterization of these kinetics is therefore of primary importance to model the process, in particular during the cooling phase. To be representative, this characterization must be carried out under conditions as close as possible to those encountered in the process: high pressure, high cooling rate, shearing, and potential presence of fibers. However, conventional apparatus such as the differential scanning calorimeter do not allow to reach these conditions. A PVTα apparatus, initially developed in the laboratory for the characterization of thermoset composites, was adapted to identify the crystallization kinetics. The aim of the presented study is to demonstrate the feasibility of the identification. This device allows the molding of a circular sample of 40 mm diameter and 6 mm thick by controlling the applied pressure on the sample and the temperature field on its surfaces. This mold is designed such as heat transfer is 1D within the thickness of the sample. It is equipped with two heat flux sensors to determine the average crystallization rate through the thickness and a displacement sensor for the determination of the volume change. The heat transfer problem between the polymer and the molding cavity is modeled by using a 1D conduction problem with a moving boundary, in which the control volume is a uniform temperature disk with a variable volume, and coupled to a crystallization kinetic model. An inverse method is used to identify the parameters of the crystallization kinetic model by minimizing an objective function based on the difference between the evolutions of the experimental and computed volume of the sample. The first validation of this methodology was to compare the kinetic parameters identified with this apparatus

  15. Measurement of intrinsic radioactive backgrounds from the 137Cs and U/Th chains in CsI(Tl) crystals

    Science.gov (United States)

    Liu, Shu-Kui; Yue, Qian; Lin, Shin-Ted; Li, Yuan-Jing; Tang, Chang-Jian; Wong Tsz-King, Henry; Xing, Hao-Yang; Yang, Chao-Wen; Zhao, Wei; Zhu, Jing-Jun

    2015-04-01

    The inorganic CsI(Tl) crystal scintillator is a candidate anti-compton detector for the China Dark matter Experiment. Studying the intrinsic radiopurity of the CsI(Tl) crystal is an issue of major importance. The timing, energy and spatial correlations, as well as the capability of pulse shape discrimination provide powerful methods for the measurement of intrinsic radiopurities. The experimental design, detector performance and event-selection algorithms are described. A total of 359×3 kg-days data from three prototypes of CsI(Tl) crystals were taken at China Jinping Underground Laboratory (CJPL), which offers a good shielding environment. The contamination levels of internal isotopes from 137Cs, 232Th and 238U series, as well as the upper bounds of 235U series are reported. Identification of the whole α peaks from U/Th decay chains and derivation of those corresponding quenching factors are achieved. Supported by National Natural Science Foundation of China (11275107, 11175099)

  16. Analysis of rocking curve measurements of LiF flight crystals for the objective crystal spectrometer on SPECTRUM-X-GAMMA

    DEFF Research Database (Denmark)

    Halm, I.; Wiebicke, H.-J.; Geppert, U.R.M.E.;

    1993-01-01

    The Objective Crystal Spectrometer on the SPECTRUM-X-GAMMA satellite will use three types of natural crystals LiF(220), Si(111), RAP(001), and a multilayer structure providing high-resolution X- ray spectroscopy of Fe, S, O, and C line regions of bright cosmic X-ray sources. 330 - 360 LiF(220...

  17. Analysis of rocking curve measurements of LiF flight crystals for the objective crystal spectrometer on SPECTRUM-X-GAMMA

    DEFF Research Database (Denmark)

    Halm, I.; Wiebicke, H.-J.; Geppert, U.R.M.E.

    1993-01-01

    The Objective Crystal Spectrometer on the SPECTRUM-X-GAMMA satellite will use three types of natural crystals LiF(220), Si(111), RAP(001), and a multilayer structure providing high-resolution X- ray spectroscopy of Fe, S, O, and C line regions of bright cosmic X-ray sources. 330 - 360 LiF(220) cr...

  18. Z-scan measurement of the nonlinear refractive index of Nd(3+), Y(3+)-codoped CaF(2) and SrF(2) crystals.

    Science.gov (United States)

    Guo, Yue; Lu, Shunbin; Su, Liangbi; Zhao, Chujun; Zhang, Han; Wen, Shuangchun

    2015-02-01

    By performing the Z-scan measurements at 800 nm using a femtosecond pulsed laser, we are able to characterize the nonlinear refractive indices of Nd, Y codoped CaF(2) and SrF(2) crystals. Based on our measured results, we conclude that the doped fluoride crystal possesses a small nonlinear refractive index and the doping of Nd(3+) and Y(3+) ions in CaF(2) can change its third-order nonlinear index, but the contribution is minor. The doped fluoride crystal may have large potential to be developed as the next generation of gain material for a high-energy laser system.

  19. A New Method for Simultaneous Measurement of the Integrated Reflectivity of Crystals at Multiple Orders of Reflection and Comparison with New Theoretical Calculations

    Energy Technology Data Exchange (ETDEWEB)

    S.G. Lee; J.G. Bak; Y.S. Jung; M. Bitter; K.W. Hill; G. Hoelzer; O. Wehrhan; E. Foerster

    2003-04-09

    This paper describes a new method for the simultaneous measurement of the integrated reflectivity of a crystal for multiple orders of reflection at a predefined Bragg angle. The technique is demonstrated with a mica crystal for Bragg angles of 43{sup o}, 47{sup o}, and 50{sup o}. The measured integrated reflectivity for Bragg reflections up to the 24th order is compared with new theoretical predictions, which are also presented in this paper.

  20. Dielectric technique to measure the twist elastic constant of liquid crystals: the case of a bent-core material.

    Science.gov (United States)

    Salamon, P; Eber, N; Seltmann, J; Lehmann, M; Gleeson, J T; Sprunt, S; Jákli, A

    2012-06-01

    The effect of director pretilt on the twist magnetic Fréedericksz transition of nematics was investigated in a planar cell. The director configuration was calculated as a function of magnetic inductance. The dielectric and optical response of the nematic liquid crystal was numerically modeled. A dielectric measurement method for determining the elastic constant K_{22} is presented. The influence of the conditions for the Mauguin effect is discussed. The theoretical predictions were confirmed by our experiments. Experimental data for all elastic constants of a bent-core nematic material are presented and discussed.

  1. Measurement of the electron and ion temperatures by the x-ray imaging crystal spectrometer on joint Texas experimental tokamak

    Science.gov (United States)

    Yan, W.; Chen, Z. Y.; Jin, W.; Lee, S. G.; Shi, Y. J.; Huang, D. W.; Tong, R. H.; Wang, S. Y.; Wei, Y. N.; Ma, T. K.; Zhuang, G.

    2016-11-01

    An x-ray imaging crystal spectrometer has been developed on joint Texas experimental tokamak for the measurement of electron and ion temperatures from the Kα spectra of helium-like argon and its satellite lines. A two-dimensional multi-wire proportional counter has been applied to detect the spectra. The electron and ion temperatures have been obtained from the Voigt fitting with the spectra of helium-like argon ions. The profiles of electron and ion temperatures show the dependence on electron density in ohmic plasmas.

  2. Simultaneous measurements of anisotropic thermal diffusivity and thermal effusivity of liquid crystals using temperature wave analysis method

    Science.gov (United States)

    Ryu, Meguya; Morikawa, Junko

    2016-11-01

    Simultaneous measurements of anisotropic thermal diffusivity and thermal effusivity in the phase transition of the liquid crystal 4‧-(pentyloxy)-4-biphenyl carbonitrile (5OCB), Cry-53-N-68-Iso, are demonstrated using the temperature wave analysis method. A detailed calibration procedure for determining thermal diffusivity (α), thermal effusivity (e), thermal conductivity (λ), and heat capacity per unit volume (Cp ρ) is proposed utilizing hexaethylene glycol monododecyl ether (C12E6) as a calibration material, the heat capacity of which is precisely determined using a calorimetric method.

  3. Structural characterization of H plasma-doped ZnO single crystals by Hall measurements and photoluminescence studies

    Energy Technology Data Exchange (ETDEWEB)

    Anwand, Wolfgang; Brauer, Gerhard; Cowan, Thomas E. [Institut fuer Strahlenphysik, Forschungszentrum Dresden-Rossendorf, PO Box 510 119, 01314 Dresden (Germany); Heera, Viton; Schmidt, Heidemarie; Skorupa, Wolfgang [Institut fuer Ionenstrahlphysik und Materialforschung, Forschungszentrum Dresden-Rossendorf, PO Box 510 119, 01314 Dresden (Germany); Wenckstern, Holger von; Brandt, Matthias; Benndorf, Gabriele; Grundmann, Marius [Fakultaet fuer Physik und Geowissenschaften, Institut fuer Experimentelle Physik II, Universitaet Leipzig, Linnestr. 5, 04103 Leipzig (Germany)

    2010-11-15

    Nominally undoped, hydrothermally grown ZnO single crystals have been investigated prior to and after doping in remote H plasma. Characterizations have been made by temperature-dependent Hall effect (TDH) and low temperature photoluminescence measurements. The H content before and after the doping has been determined using nuclear reaction analysis and is compared to the density of shallow donors derived from the TDH measurements. The electrical properties of the as-grown ZnO single crystals are found to differ significantly. This is ascribed to the density ratio of shallow donors and compensating acceptors. PL measurements showed that Al{sub Zn}, Ga{sub Zn}, and interstitial zinc (Zn{sub i}) are prominent shallow donors in the as-grown samples. Remote H plasma treatment produced a metallic conducting near-surface layer thus masking the electrical properties of the bulk. The electrical properties of the investigated samples are very similar after the treatment, independent of the as-grown state, because the density of shallow donors far exceeds that of compensating acceptors in the affected near-surface region. The maximum of the broad near-bandedge emission is found to be located at 3.3595 eV due to the high doping density. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Measurement of the g p -> K^0 Sigma^+ reaction with the Crystal Ball/TAPS detectors at the Mainz Microtron

    CERN Document Server

    Aguar-Bartolomé, P; Arends, H J; Bantawa, K; Beck, R; Bekrenev, V; Berghäuser, H; Braghieri, A; Briscoe, W J; Brudvik, J; Cherepnya, S; Codling, R F B; Demissie, B; Dieterle, M; Downie, E J; Drexler, P; Fil'kov, L V; Glazier, D I; Gregor, R; Hamilton, D; Heid, E; Hornidge, D; Howdle, D; Isaksson, L; Jaegle, I; Jahn, O; Jude, T C; Kashevarov, V L; Keshelashvili, I; Kondratiev, R; Korolija, M; Kotulla, M; Koulbardis, A; Kruglov, S; Krusche, B; Lisin, V; Livingston, K; MacGregor, I J D; Maghrbi, Y; Mancel, J; Manley, D M; McNicoll, E F; Mekterovic, D; Metag, V; Mushkarenkov, A; Nefkens, B M K; Nikolaev, A; Novotny, R; Oberle, M; Ortega, H; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Pheron, F; Polonski, A; Prakhov, S; Robinson, J; Rosner, G; Rostomyan, T; Schumann, S; Sikora, M H; Sober, D I; Starostin, A; Strakovsky, I I; Suarez, I M; Supek, I; Tarbert, C M; Thiel, M; Thomas, A; Unverzagt, M; Watts, D P; Werthmüller, D; Witthauer, L; Zehr, F

    2013-01-01

    The g p -> K^0 Sigma^+ reaction has been measured from threshold to Eg=1.45~GeV (W_cm=1.9~GeV) using the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. In the present experiment, this reaction was searched for in the 3pi^0 p final state, assuming K^0_S -> pi^0 pi^0 and Sigma^+ -> pi^0 p. The experimental results include total and differential cross sections as well as the polarization of the recoil hyperon. The new data significantly improve the empirical knowledge about the g p -> K^0 Sigma^+ reaction in the measured energy range. The results are compared to previous measurements and model predictions. It was demonstrated that adding the present g p -> K^0 Sigma^+ results to existing data allowed a better description of this reaction with various models.

  5. Calibrating the measurement of wavelength-dependent second harmonic generation from biological tissues with a BaB₂O₄ crystal.

    Science.gov (United States)

    Shen, Mengzhe; Zhao, Jianhua; Zeng, Haishan; Tang, Shuo

    2013-03-01

    Although second harmonic generation (SHG) imaging has emerged as a powerful tool for imaging biological tissues with submicron resolution, the excitation wavelength dependence of SHG intensity in biological tissues is an optical property that is not fully understood so far. We first calibrate system factors which may potentially affect the accuracy of the wavelength-dependent SHG measurement. Then our calibration is validated by measuring the wavelength dependence of SHG signal from a BaB₂O₄ crystal under different focusing conditions and comparing with the theoretical calculations. The good agreement between the experimental results and theoretical calculations demonstrates that we have established a reliable method to validate wavelength-dependent SHG measurement over a broad wavelength range. We also investigate the wavelength dependence of a 10-μm thick mouse tendon tissue in both forward and backward directions. It is found that SHG of mouse tendon tissue decreases monotonically for excitation from 750 to 950 nm.

  6. Design, construction, and measurements of a bender, which provide constant position of the central part of the crystal monocromator during bending process (abstract)

    Science.gov (United States)

    Artemev, A.; Artemiev, N.; Busetto, E.; Franc, F.; Hrdý, J.; Mrázek, D.; Savoia, A.

    2002-03-01

    The bender described is a part of the double crystal monochromator for the QUICKEXAFS spectrometer, which is under development for ELETTRA. Technical specification for the bender include the following: constant position of the central point of the crystal during the bending process, the full size of the crystal must be as small as possible in the dynamic bending process, and the bender must be highly vacuum compatible. To satisfy all of these demands we propose a new scheme for a bender of rectangular crystal with four living supports. The bender has two inner wings, which bear two inner crystal supports, and two outer wings, which bear two outer supports. These wings are moved by two cones placed on the same rod. The cones have different profiles. In order to keep the central part of the crystal in a constant position during the bending process these cone profiles are designed and manufactured in a very special way. Measurements of the bender characteristics were made with the help of a test bench. Instead of a Si single crystal we used a bronze plate of the same size, which had very similar elastic constants. The full scattering of the position of the central part of the bronze plate during the bending process is less then 100 μm. The measured profile of the plate bent to about 506 mm was compared with a circle fitted by the least square method. The relative difference between measured and fitted radius appeared to be about 10-5.

  7. In situ thermal characterization of cooling/crystallizing lavas during rheology measurements and implications for lava flow emplacement

    Science.gov (United States)

    Kolzenburg, S.; Giordano, D.; Cimarelli, C.; Dingwell, D. B.

    2016-12-01

    Transport properties of natural silicate melts at super-liquidus temperatures are reasonably well understood. However, migration and transport of silicate melts in the Earth's crust and at its surface generally occur at sub-liquidus temperatures and in settings where the melts undergo crystallization under various cooling and/or decompression conditions. In such dynamic situations the occurrence of processes such as the release of latent heat during phase changes, viscous heating, thermal advection and -inertia, and changing heat capacity, all represent potential influences on the state, and thereby on the physico-chemical behavior of the system. To date, rheological data at sub-liquidus temperatures are scarce and cooling-rate dependent, disequilibrium rheological data are virtually absent. In fact, no in situ thermal characterization of liquid or multiphase mixtures during rheological experiments, under either static or dynamic thermal conditions has been presented to date. Here we describe a new experimental setup for in situ thermal characterization of cooling/crystallizing lavas during viscosity measurement at temperatures up to 1600 °C. We use this device to recover in situ, real-time, observations of the combined rheological and thermal evolution of natural, re-melted lava samples during the transient disequilibrium conditions characteristic of lava flows and shallow crustal magma migration and storage systems in nature. We present the calibration procedure and the method employed to recover the thermal evolution of an experimental sample during flow in varying shear regimes, assess the experimental uncertainty and show the ability of the apparatus to measure the release of latent heat of crystallization during transient rheological experiments. We further report the results from a first experimental study on the rheological and thermal evolution of a basaltic lava undergoing continuous cooling at a series of different cooling rates and discuss the

  8. Investigation of Crystal Surface Finish and Geometry on Single LYSO Scintillator Detector Performance for Depth-of-Interaction Measurement with Silicon Photomultipliers.

    Science.gov (United States)

    Bircher, Chad; Shao, Yiping

    2012-11-21

    Depth of Interaction (DOI) information can improve quality of reconstructed images acquired from Positron Emission Tomography (PET), especially in high resolution and compact scanners dedicated for breast, brain, or small animal imaging applications. Additionally, clinical scanners with time of flight capability can also benefit from DOI information. One of the most promising methods of determining DOI in a crystal involves reading the signal from two ends of a scintillation crystal, and calculating the signal ratio between the two detectors. This method is known to deliver a better DOI resolution with rough crystals compared to highly polished crystals. However, what is still not well studied is how much of a tradeoff is involved between spatial, energy, temporal, and DOI resolutions as a function of the crystal surface treatment and geometry with the use of Silicon Photomultipliers (SiPM) as the photo detectors. This study investigates the effects of different crystal surface finishes and geometries on energy, timing and DOI resolutions at different crystal depths. The results show that for LYSO scintillators of 1.5×1.5×20 mm(3) and 2×2×20 mm(3) with their surfaces finished from 0.5 to 30 micron roughness, almost the same energy and coincidence timing resolutions were maintained, around 15% and 2.4 ns respectively across different crystal depths, while the DOI resolutions were steadily improved from worse than 5 mm to better than 2 mm. They demonstrate that crystal roughness, with proper surface preparing, does not have a significant effect on the energy and coincidence timing resolutions in the crystals examined, and there does not appear to be a tradeoff between improving DOI resolution and degrading other detector performances. These results will be valuable to guide the selection of crystal surface conditions for developing a DOI measurable PET detector with a full array of LYSO scintillators coupled to SiPM arrays.

  9. Measurements of Thermal Conductivity and Thermal Diffusivity of Hen Egg-White Lysozyme Crystals and Its Solution Using the Transient Short Hot Wire Method

    Science.gov (United States)

    Fujiwara, Seiji; Maki, Syou; Maekawa, Ryunosuke; Tanaka, Seiichi; Hagiwara, Masayuki

    2017-08-01

    Protein crystals are an essentially important biological sample to advance the analysis of X-ray structure, but their thermophysical properties, especially thermal conductivity and thermal diffusivity, have not been studied sufficiently. This current situation can be attributed to various kinds of technical problems; e.g., the fragility of protein crystals and the difficulty of nucleation control. Ideally speaking, protein crystallization should be carried out under a " containerless condition" to eliminate any mechanical distortion of the crystals from the walls. To realize the condition, we have developed an original crystallization method by means of the magneto-Archimedes effect. In this paper, a transient short hot wire method was combined with the technique of magneto-Archimedes effect to realize simultaneous measurement of thermal conductivity and thermal diffusivity of hen egg-white lysozyme (HEWL) crystals. As the results, thermal conductivity and thermal diffusivity of HEWL crystals were found to be 0.410-0.438 \\hbox {W}\\cdot \\hbox {m}^{-1}\\cdot \\hbox {K}^{-1} and 3.77-5.18× 10^{-8} \\hbox {m}2\\cdot \\hbox {s}^{-1}, respectively. We clarified by the crystallizing process of HEWL that the crystals were magnetically levitated at the air-liquid interface and the short hot wire was completely buried into them as the crystals grew. We also measured the HEWL solution by the same methods. The thermal conductivity of the solution had almost the same value as that of water and had little dependency on the concentration of HEWL, but the thermal diffusivity was unclear.

  10. Measurements on microscopic barium ferrite single crystals using a vibrating reed magnetometer

    Science.gov (United States)

    Schippan, R.; Hempel, K. A.

    1982-11-01

    The magnetization processes occuring in a small individual particle (dimensions about 4 μm) of a barium ferrite single crystal are investigated using a high sensitivity vibrating reed magnetometer.1,2 With this apparatus magnetic moments smaller than 10-9 A cm2 may be detected if the particle is fixed to a hollow quartz reed which is kept under vacuum. The operating frequency is tuned to the resonance frequency of the reed. The examination exhibits a perfect rectangular primary hysteresis loop which indicates that the magnetic moment of the sample is completely reversed by a single Barkhausen jump. By repeating the reversal, a wide range of jump field strengths is revealed. Two types of minor loops are demonstrated depending on the magnitude of the jump field strength.

  11. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang; Yizheng Zhu

    2005-04-01

    This report summarizes technical progress October 2004-March 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report.

  12. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Anbo Wang

    2007-03-31

    This report summarizes technical progress October 2006 - March 2007 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. During the second phase, an alternative high temperature sensing system based on Fabry-Perot interferometry was developed that offers a number of advantages over the BPDI solution. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. The sapphire wafer-based interferometric sensing system that was installed at TECO's Polk Power Station remained in operation for seven months. Our efforts have been focused on monitoring and analyzing the real-time data collected, and preparing for a second field test.

  13. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang

    2004-04-01

    This report summarizes technical progress over the third six month period of the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Research efforts were focused on sensor probe design and machining, sensor electronics design, software algorithm design, sensor field installation procedures, and sensor remote data access and control. Field testing will begin in the next several weeks.

  14. Low coherence technique to interrogate optical sensors based on selectively filled double-core photonic crystal fiber for temperature measurement

    Science.gov (United States)

    Li, Kun; Jiang, Meng; Zhao, Zhongze; Wang, Zeming

    2017-04-01

    In this paper, an optical fiber sensing system based on low coherence interferometry (LCI) is proposed and demonstrated to interrogate sensors comprised of selectively filled double-core photonic crystal fiber (SFDC-PCF). The sensor used here is made by selectively filling about 1/3 area of air holes in the cladding of photonic crystal fiber with distilled water. So the dual-core in the sensor has different effective refractive indices, resulting in a phase delay between two lights transmitting in the fiber. The phase delay of the sensor can be compensated by a Mach-Zehnder interferometer with a scanning optical tunable delay line in one arm of the interferometer, namely temporal interrogation. By tracking the value of phase delay, the change of the measurand can be detected. Temperature measurement is carried out to testify the system performance. An average sensitivity of 0.9 μm/°C is achieved within the temperature range of 29-92 °C. This work provides a new thinking for fiber sensing technology based on LCI. The proposed all-fiber sensing system, with the merits of cost-effective, stability, and flexibility, can demodulate the SFDC-PCF sensor signals well. Further improvements such as better sensitivity, larger measurement range and multiplexing efficiency can be realized by tailoring the PCF sensor's structure.

  15. Temperature dependence of full set tensor properties of KTiOPO4 single crystal measured from one sample

    Science.gov (United States)

    Zhang, Yang; Tang, Liguo; Ji, Nianjing; Liu, Gang; Wang, Jiyang; Jiang, Huaidong; Cao, Wenwu

    2016-03-01

    The temperature dependence of the complete set of elastic, dielectric, and piezoelectric constants of KTiOPO4 single crystal has been measured from 20 °C to 150 °C. All 17 independent constants for the mm2 symmetry piezoelectric crystal were measured from one sample using extended resonance ultrasound spectroscopy (RUS), which guaranteed the self-consistency of the matrix data. The unique characteristics of the RUS method allowed the accomplishment of such a challenging task, which could not be done by any other existing methods. It was found that the elastic constants ( c11 E , c13 E , c22 E , and c33 E ) and piezoelectric constants ( d 15 , d 24 , and d 32 ) strongly depend on temperature, while other constants are only weakly temperature dependent in this temperature range. These as-grown single domain data allowed us to calculate the orientation dependence of elastic, dielectric, and piezoelectric properties of KTiOPO4, which are useful for finding the optimum cut for particular applications.

  16. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Anbo Wang

    2007-03-31

    This report summarizes technical progress October 2006 - March 2007 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. During the second phase, an alternative high temperature sensing system based on Fabry-Perot interferometry was developed that offers a number of advantages over the BPDI solution. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. The sapphire wafer-based interferometric sensing system that was installed at TECO's Polk Power Station remained in operation for seven months. Our efforts have been focused on monitoring and analyzing the real-time data collected, and preparing for a second field test.

  17. ON-LINE SELF-CALIBRATING SINGLE CRYSTAL SAPPHIRE OPTICAL SENSOR INSTRUMENTATION FOR ACCURATE AND RELIABLE COAL GASIFIER TEMPERATURE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang; Zhengyu Huang; Yizheng Zhu

    2005-04-01

    This report summarizes technical progress October 2004-March 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the BPDI sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report.

  18. L-Asparagine crystals with wide gap semiconductor features: optical absorption measurements and density functional theory computations.

    Science.gov (United States)

    Zanatta, G; Gottfried, C; Silva, A M; Caetano, E W S; Sales, F A M; Freire, V N

    2014-03-28

    Results of optical absorption measurements are presented together with calculated structural, electronic, and optical properties for the anhydrous monoclinic L-asparagine crystal. Density functional theory (DFT) within the generalized gradient approximation (GGA) including dispersion effects (TS, Grimme) was employed to perform the calculations. The optical absorption measurements revealed that the anhydrous monoclinic L-asparagine crystal is a wide band gap material with 4.95 eV main gap energy. DFT-GGA+TS simulations, on the other hand, produced structural parameters in very good agreement with X-ray data. The lattice parameter differences Δa, Δb, Δc between theory and experiment were as small as 0.020, 0.051, and 0.022 Å, respectively. The calculated band gap energy is smaller than the experimental data by about 15%, with a 4.23 eV indirect band gap corresponding to Z → Γ and Z → β transitions. Three other indirect band gaps of 4.30 eV, 4.32 eV, and 4.36 eV are assigned to α3 → Γ, α1 → Γ, and α2 → Γ transitions, respectively. Δ-sol computations, on the other hand, predict a main band gap of 5.00 eV, just 50 meV above the experimental value. Electronic wavefunctions mainly originating from O 2p-carboxyl, C 2p-side chain, and C 2p-carboxyl orbitals contribute most significantly to the highest valence and lowest conduction energy bands, respectively. By varying the lattice parameters from their converged equilibrium values, we show that the unit cell is less stiff along the b direction than for the a and c directions. Effective mass calculations suggest that hole transport behavior is more anisotropic than electron transport, but the mass values allow for some charge mobility except along a direction perpendicular to the molecular layers of L-asparagine which form the crystal, so anhydrous monoclinic L-asparagine crystals could behave as wide gap semiconductors. Finally, the calculations point to a high degree of optical

  19. L-asparagine crystals with wide gap semiconductor features: Optical absorption measurements and density functional theory computations

    Energy Technology Data Exchange (ETDEWEB)

    Zanatta, G.; Gottfried, C. [Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, 90035-003 Porto Alegre-RS (Brazil); Silva, A. M. [Universidade Estadual do Piauí, 64260-000 Piripiri-Pi (Brazil); Caetano, E. W. S., E-mail: ewcaetano@gmail.com [Instituto de Educação, Ciência e Tecnologia do Ceará, 60040-531 Fortaleza-CE (Brazil); Sales, F. A. M.; Freire, V. N. [Departamento de Física, Universidade Federal do Ceará, Caixa Postal 6030, 60455-760 Fortaleza-CE (Brazil)

    2014-03-28

    Results of optical absorption measurements are presented together with calculated structural, electronic, and optical properties for the anhydrous monoclinic L-asparagine crystal. Density functional theory (DFT) within the generalized gradient approximation (GGA) including dispersion effects (TS, Grimme) was employed to perform the calculations. The optical absorption measurements revealed that the anhydrous monoclinic L-asparagine crystal is a wide band gap material with 4.95 eV main gap energy. DFT-GGA+TS simulations, on the other hand, produced structural parameters in very good agreement with X-ray data. The lattice parameter differences Δa, Δb, Δc between theory and experiment were as small as 0.020, 0.051, and 0.022 Å, respectively. The calculated band gap energy is smaller than the experimental data by about 15%, with a 4.23 eV indirect band gap corresponding to Z → Γ and Z → β transitions. Three other indirect band gaps of 4.30 eV, 4.32 eV, and 4.36 eV are assigned to α3 → Γ, α1 → Γ, and α2 → Γ transitions, respectively. Δ-sol computations, on the other hand, predict a main band gap of 5.00 eV, just 50 meV above the experimental value. Electronic wavefunctions mainly originating from O 2p–carboxyl, C 2p–side chain, and C 2p–carboxyl orbitals contribute most significantly to the highest valence and lowest conduction energy bands, respectively. By varying the lattice parameters from their converged equilibrium values, we show that the unit cell is less stiff along the b direction than for the a and c directions. Effective mass calculations suggest that hole transport behavior is more anisotropic than electron transport, but the mass values allow for some charge mobility except along a direction perpendicular to the molecular layers of L-asparagine which form the crystal, so anhydrous monoclinic L-asparagine crystals could behave as wide gap semiconductors. Finally, the calculations point to a high degree of optical

  20. Measurement of the Zak phase of photonic bands through the interface states of metasurface/photonic crystal

    CERN Document Server

    Wang, Qiang; Liu, Hui; Zhu, Shining; Chan, C T

    2016-01-01

    Zak phase labels the topological property of one-dimensional Bloch Bands. Here we propose a scheme and experimentally measure the Zak phase in a photonic system. The Zak phase of a bulk band of is related to the topological properties of the two band gaps sandwiching this band, which in turn can be inferred from the existence or absence of an interface state. Using reflection spectrum measurement, we determined the existence of interface states in the gaps, and then obtained the Zak phases. The knowledge of Zak phases can also help us predict the existence of interface states between a metasurface and a photonic crystal. By manipulating the property of the metasurface, we can further tune the excitation frequency and the polarization of the interface state.

  1. Neutron calibration facility with an Am-Be source for pulse shape discrimination measurement of CsI(Tl) crystals

    CERN Document Server

    Lee, H S; Choi, J H; Choi, S; Hahn, I S; Jeon, E J; Joo, H W; Kang, W G; Kim, G B; Kim, H J; Kim, K W; Kim, S C; Kim, S K; Kim, Y D; Kim, Y H; Lee, J H; Lee, J K; Leonard, D S; Li, J; Myung, S S; Olsen, S L; So, J H

    2014-01-01

    We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to nuclear recoils induced by neutrons from the Am-Be source and comparing them with the response to electron recoils produced by Compton scattering of 662-keV $\\gamma$-rays from a $^{137}$Cs source. The measured results on pulse shape discrimination (PSD) between nuclear- and electron-recoil events are quantified in terms of quality factors. A comparison with similar result from a neutron reactor demonstrate the feasibility of performing calibrations of PSD measurements using neutrons from a Am-Be source.

  2. Apparatus for measurement of acoustic wave propagation under uniaxial loading with application to measurement of third-order elastic constants of piezoelectric single crystals.

    Science.gov (United States)

    Zhang, Haifeng; Kosinski, J A; Karim, Md Afzalul

    2013-05-01

    We describe an apparatus for the measurement of acoustic wave propagation under uniaxial loading featuring a special mechanism designed to assure a uniform mechanical load on a cube-shaped sample of piezoelectric material. We demonstrate the utility of the apparatus by determining the effects of stresses on acoustic wave speed, which forms a foundation for the final determination of the third-order elastic constants of langasite and langatate single crystals. The transit time method is used to determine changes in acoustic wave velocity as the loading is varied. In order to minimize error and improve the accuracy of the wave speed measurements, the cross correlation method is used to determine the small changes in the time of flight. Typical experimental results are presented and discussed.

  3. Research on 2D representation method of wireless Micro-Ball endoscopic images.

    Science.gov (United States)

    Wang, Dan; Xie, Xiang; Li, Guolin; Gu, Yingke; Yin, Zheng; Wang, Zhihua

    2012-01-01

    Nowadays the interpretation of the images acquired by wireless endoscopy system is a tedious job for doctors. A viable solution is to construct a map, which is the 2D representation of gastrointestinal (GI) tract to reduce the redundancy of images and improve the understandability of them. The work reported in this paper addresses the problem of the 2D representation of GI tract based on a new wireless Micro-Ball endoscopy system with multiple image sensors. This paper firstly models the problem of constructing the map, and then discusses mainly on the issues of perspective distortion correction, image preprocessing and image registration, which lie in the whole problem. The perspective distortion correction algorithm is realized based on attitude angles, while the image registration is based on phase correlation method (PCM) and scale invariant feature transform (SIFT) combined with particular image preprocessing methods. Based on R channels of images, the algorithm can deal with 26.3% to 100% of image registration when the ratio of overlap varies from 25% to 80%. The performance and effectiveness of the algorithms are verified by experiments.

  4. Observation of applied voltage response of dye-doped liquid crystal by optical measurement of real and imaginary parts of complex refractive index

    Science.gov (United States)

    Sakamoto, Moritsugu; Bannai, Kenta; Noda, Kohei; Sasaki, Tomoyuki; Ono, Hiroshi

    2017-09-01

    The behavior of liquid crystal (LC) molecules and dye molecules in a dye-doped liquid crystal (DDLC) under a voltage application condition was quantitatively investigated. To observe the reorientation of these molecules, the real and imaginary parts of the complex refractive index were simultaneously and individually measured using an optical interferometer. The obtained results indicate that the alignment of dye molecules doped in DDLC occurs following the electrically responding LC molecules, near the Freedericksz transition region of LC.

  5. Direct observation of plasticity and quantitative hardness measurements in single crystal cyclotrimethylene trinitramine by nanoindention

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Kyle J [Los Alamos National Laboratory; Hooks, David E [Los Alamos National Laboratory; Bahr, David F [WSU

    2008-01-01

    Investigation of deformation beginning with elasticity and continuing through the elastic-plastic transition to incipient cracking has been conducted for (210), (021), and (001) oriented single crystals of the explosive cyclotrimethylene trinitramine, commonly known as 'RDX' Instrumented indentation was performed with a conical tip over a range of loads. The resulting load-depth data exhibited distinct, reproducible, orientation dependent load excursions demonstrating elastic-plastic transitions. Indent impressions were imaged by scanning probe microscopy. Impressions on the (210) and (001) planes showed deformation pileup features associated with zone axes of slip planes. Clearly discernable slip traces were evident on the (210) plane. The (021) indentations produced significant material pile-up surrounding the impression, but did not contain discrete features associable with specific zone axes. All of the orientations exhibited cracking thresholds at very low loads. The reduced moduli were anisotropic and the hardness's were isotropic indicating limited plasticity. Maximum shear stresses estimated from a Hertzian model, at load excursions, were within a factor of 10 of published shear moduli indicating deformation initiated near the theoretical yield strength presumably by homogeneous nucleation of dislocations. The material strength parameters and apparent deformation pathways inferred from this work are compared to historical microhardness testing and interpretation of anisotropic hardness in which ambiguity of results can be attributed to the effects of cracking and simultaneous slip on multiple systems.

  6. Angle-Resolved Scatter Measurements of Laser Damaged DKDP Crystals Using a Bi-Directional Scatter Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fluck, R; Wegner, P; Sheehan, L; Hackel, L A

    2000-12-22

    We built a bi-directional scatter diagnostics to measure and quantify losses due to scattering and absorption of harmonic conversion crystals (DKDP) for the National Ignition Facility (NIF). The main issues to be addressed are (1) amount of total energy reaching the target if the target hole was {+-}200 {micro}rad in size, (2) distribution of energy inside the target hole, (3) collateral damage of other optics by scattered light. The scatter diagnostics enables angle-resolved measurements at 351 nm, and is capable of both near specular transmission and large angle scatter measurements. In the near specular setup, the transmission can be measured within {+-}65 {micro}rad up to {+-}60 mrad acceptance angle. A silicon photo detector and a scientific-grade CCD camera provide total energy and energy distribution. A linear swing arm detection system enables large angle scatter measurements of 360{sup o}, in principal, with step sizes as small as 0.01{sup o} and different collection angle ranging between 1 and 20 mad. In this paper, scatter effects from laser damage and final finishing process of DKDP are discussed.

  7. Imaging crystal spectrometer for high-resolution x-ray measurements on electron beam ion traps and tokamaks

    Science.gov (United States)

    Beiersdorfer, P.; Magee, E. W.; Hell, N.; Brown, G. V.

    2016-11-01

    We describe a crystal spectrometer implemented on the Livermore electron beam ion traps that employ two spherically bent quartz crystals and a cryogenically cooled back-illuminated charge-coupled device detector to measure x rays with a nominal resolving power of λ/Δλ ≥ 10 000. Its focusing properties allow us to record x rays either with the plane of dispersion perpendicular or parallel to the electron beam and, thus, to preferentially select one of the two linear x-ray polarization components. Moreover, by choice of dispersion plane and focussing conditions, we use the instrument either to image the distribution of the ions within the 2 cm long trap region, or to concentrate x rays of a given energy to a point on the detector, which optimizes the signal-to-noise ratio. We demonstrate the operation and utility of the new instrument by presenting spectra of Mo34+, which prepares the instrument for use as a core impurity diagnostic on the NSTX-U spherical torus and other magnetic fusion devices that employ molybdenum as plasma facing components.

  8. Adsorption of Pluronic F-127 on Surfaces with Different Hydrophobicities Probed by Quartz Crystal Microbalance with Dissipation

    NARCIS (Netherlands)

    Nejadnik, M.R.; Olsson, A.L.J.; Sharma, P.K.; Mei, van der H.C.; Norde, W.; Busscher, H.J.

    2009-01-01

    Triblock copolymers of polyethylene oxide (PEO) and polypropylene oxide (PPO), that is, PEOn-PPOm-PEOn, better known as Pluronic can adsorb to surfaces in either a pancake or a brushlike configuration. The brushlike configuration is advantageous in numerous applications, since it constitutes a

  9. Adsorption of Saliva Related Protein on Denture Materials: An X-Ray Photoelectron Spectroscopy and Quartz Crystal Microbalance Study

    Directory of Open Access Journals (Sweden)

    Akiko Miyake

    2016-01-01

    Full Text Available The aim of this study was to evaluate the difference in the adsorption behavior of different types of bovine salivary proteins on the PMMA and Ti QCM sensors are fabricated by spin-coating and sputtering onto bare QCM sensors by using QCM and X-ray photoelectron spectroscopy (XPS. SPM, XPS, and contact angle investigations were carried out to determine the chemical composition and surface wettability of the QCM surface. We discuss the quality of each sensor and evaluate the potential of the high-frequency QCM sensors by investigating the binding between the QCM sensor and the proteins albumin and mucin (a salivary-related protein. The SPM image showed a relatively homogeneous surface with nano-order roughness. The XPS survey spectra of the thin films coated on the sensors were similar to the binding energy of the characteristic spectra of PMMA and Ti. Additionally, the amount of salivary-related protein on the PMMA QCM sensor was higher than those on the Ti and Au QCM sensors. The difference of protein adsorption is proposed to be related to the wettability of each material. The PMMA and Ti QCM sensors are useful tools to study the adsorption and desorption of albumin and mucin on denture surfaces.

  10. Measurement of Short Living Baryon Magnetic Moment using Bent Crystals at SPS and LHC

    CERN Document Server

    Burmistrov, L; Ivanov, Yu; Massacrier, L; Robbe, P; Scandale, W; Stocchi, A

    2016-01-01

    The magnetic moments of baryons containing u,d and s quarks have been extensively studied and measured. The experimental results are all obtained by a well-assessed method that consists in measuring the polarisation vector of the incoming particles and the precession angle when the particle is travelling through an intense magnetic field. The polarization is evaluated by analysing the angular distribution of the decay products. No measurement of magnetic moments of charm or beauty baryons (and τ leptons) has been performed so far. The main reason is the lifetimes of charm/beauty baryons, too short to measure the magnetic moment by standard techniques. Historically, the prediction of baryon magnetic moments was one of the striking successes of the quark model. The importance of the measurement of heavy quark magnetic moment is to test the possibility that the charmed and/or beauty quarks has an anomalous magnetic moment, arising if those quarks are composite objects. Measurements on magnetic moments of heav...

  11. Combined High Spectral Resolution Lidar and Millimeter Wavelength Radar Measurement of Ice Crystal Precipitation

    Energy Technology Data Exchange (ETDEWEB)

    Eloranta, Edwin [Univ. of Wisconsin, Madison, WI (United States)

    2016-10-28

    The goal of this research has been to improve measurements of snowfall using a combination of millimeter-wavelength radar and High Spectral Resolution Lidar (HSRL) Observations. Snowflakes are large compared to the 532nm HSRL wavelength and small compared to the 3.2 and 8.6 mm wavelength radars used in this study. This places the particles in the optical scattering regime of the HSRL, where extinction cross-section is proportional to the projected area of the particles, and in the Rayleigh regime for the radar, where the backscatter cross-section is proportional to the mass-squared of the particles. Forming a ratio of the radar measured cross-section to the HSRL measured cross section eliminates any dependence on the number of scattering particles, yielding a quantity proportional to the average mass-squared of the snowflakes over the average area of the flakes. Using simultaneous radar measurements of particle fall velocities, which are dependent particle mass and cross-sectional area it is possible to derive the average mass of the snow flakes, and with the radar measured fall velocities compute the snowfall rate. Since this retrieval requires the optical extinction cross-section we began by considering errors this quantity. The HSRL is particularly good at measuring the backscatter cross-section. In previous studies of snowfall in the high Arctic were able to estimate the extinction cross-section directly as a fixed ratio to the backscatter cross-section. Measurements acquired in the STORMVEX experiment in Colorado showed that this approach was not valid in mid-latitude snowfalls and that direct measurement of the extinction cross-section is required. Attempts to measure the extinction directly uncovered shortcomings in thermal regulation and mechanical stability of the newly deployed DOE HSRL systems. These problems were largely mitigated by modifications installed in both of the DOE systems. We also investigated other sources of error in the HSRL direct

  12. In-Plane Electronic Anisotropy of Underdoped ___122___ Fe-Arsenide Superconductors Revealed by Measurements of Detwinned Single Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Ian Randal

    2012-05-08

    The parent phases of the Fe-arsenide superconductors harbor an antiferromagnetic ground state. Significantly, the Neel transition is either preceded or accompanied by a structural transition that breaks the four fold symmetry of the high-temperature lattice. Borrowing language from the field of soft condensed matter physics, this broken discrete rotational symmetry is widely referred to as an Ising nematic phase transition. Understanding the origin of this effect is a key component of a complete theoretical description of the occurrence of superconductivity in this family of compounds, motivating both theoretical and experimental investigation of the nematic transition and the associated in-plane anisotropy. Here we review recent experimental progress in determining the intrinsic in-plane electronic anisotropy as revealed by resistivity, reflectivity and ARPES measurements of detwinned single crystals of underdoped Fe arsenide superconductors in the '122' family of compounds.

  13. α-Amylase sensor based on the degradation of oligosaccharide hydrogel films monitored with a quartz crystal sensor.

    Science.gov (United States)

    Gibbs, Martin John; Biela, Anna; Krause, Steffi

    2015-05-15

    α-Amylase hydrolyses starch molecules to produce smaller oligosaccharides and sugars. Amylases are of great importance in biotechnology and find application in fermentation, detergents, food and the paper industry. The measurement of α-amylase activity in serum and urine has been used in the diagnosis of acute pancreatitis. Salivary amylase has also been shown to be a stress indicator. Sensor coatings suitable for the detection of α-amylase activity have been developed. Oligosaccharides such as glycogen and amylopectin were spin-coated onto gold coated quartz crystals with a base frequency of 10 MHz. The films were subsequently cross-linked with hexamethylene diisocyanate. Film degradation was monitored with a quartz crystal microbalance (QCM) and electrochemical impedance measurements. The films were shown to be stable in phosphate buffered saline (PBS). Addition of α-amylase to the solution resulted in the rapid degradation of the films. The maximum rate of degradation was found to be strongly dependent on the amylase activity in the range typically found in serum when diagnosing pancreatitis (0.08-8 U/ml). Sensor responses in serum were found to be very similar to those obtained in buffer indicating the absence of non-specific binding. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  15. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  16. Electrochemical Quartz Crystal Nanobalance

    Science.gov (United States)

    Inzelt, György

    The method of piezoelectric microgravimetry (nanogravimetry) using an electrochemical quartz crystal microbalance (EQCM) or nanobalance (EQCN) can be considered as a novel and much more sensitive version of electrogravimetry. The EQCN technique has become a widely used technique in several areas of electrochemistry, electroanalytical chemistry, bioelectrochemistry, etc. [1-10]. Obviously, mass changes occurring during adsorption, sorption, electrosorption, electrodeposition, or spontaneous deposition can be followed, which is very helpful for the elucidation of reaction mechanism via identification of the species accumulated on the surface. These investigations include metal and alloy deposition, underpotential deposition, electroplating, synthesis of conducting polymers by electropolymerization, adsorption of biologically active materials, and analytical determination of small ions and biomolecules. Of course, the opposite processes, i.e., spontaneous dissolution, electrodissolution, corrosion, can also be studied. Electrochemical oscillations, in which the formation and oxidation of chemisorbed molecular fragments play a determining role, have been studied, too. The majority of the investigations have been devoted to ion and solvent transport associated with the redox transformations of electrochemically active polymers. Similar studies have been carried out regarding polynuclear surface layers such as metal hexacyanometalates as well as inorganic and organic microcrystals of different compositions.

  17. In-Situ Partial Pressure Measurements and Visual Observation during Crystal Growth of ZnSe by Seeded Physical Vapor Transport

    Science.gov (United States)

    Su, Ching-Hua; Feth, Shari; Lehoczky, Sandor L.

    1999-01-01

    An in-situ monitoring furnace was constructed with side windows to perform partial pressure measurements by optical absorption and visual observation of the growing crystal. A fused silica -rowth ampoule with a 4.5 cm long square tube between the source and the seed was prepared for the optical absorption measurements. A ZnSe crystal was grown by the seeded physical vapor transport (PVT) technique in the horizontal configuration. The growth temperature was 1120 C and the furnace translation rate was 3nmVday. Partial pressures of Se2, P(sub Se2), at three locations along the length of the growth ampoule were measured at 90 min intervals during the growth process. The measured P (sub Se2) were in the range of 2.0 to 6.5 x 10(exp -3) atm. The P(sub Se2) results indicated that the partial pressure profile was inconsistent with the results of the one-dimensional diffusion mass transport model and that the source composition shifted toward Se-rich during the run, i.e. the grown crystal was more Zn-rich than the source. The visual observation showed that the seed crystal first etched back, with greater thermal etching occurring along the edges of the seed crystal. Once the growth started, the crystal crew in a predominately contactless mode and facets were evident during growth. The crystal did not grow symmetrically which is believed to be due to the unintentional asymmetry of the radial thermal profile in the furnace.

  18. Extreme group index measured and calculated in 2D SOI-based photonic crystal waveguides

    DEFF Research Database (Denmark)

    Lavrinenko, Andrei; Jacobsen, Rune Shim; Fage-Pedersen, Jacob;

    2005-01-01

    lattice of air-holes in the 216-nm thick silicon layer in an SOI material. Experimental transmission spectra show a mode cut-off around 1562.5 nm for the fundamental photonic bandgap mode. In order to measure and model the group index of modes in the PCW, a time-of-flight (ToF) method is applied....

  19. Measurements on power-conversion gain and noise ratio of the 1N26 crystal rectifiers

    NARCIS (Netherlands)

    Dymanus, A.; Bouwknegt, A.

    1960-01-01

    Measurements have been performed on power conversion gain G and noise ratio n of a number of 1N26 silicon rectifiers (Sylvania Co., U.S.A.) using well-known techniques. The noise ratio has been investigated both with microwave excitation (10−6-10−3 W at 24 GHz) and with DC-excitation by currents up

  20. Study of Ice Crystal Orientation in Cirrus Clouds based on Satellite Polarized Radiance Measurements

    OpenAIRE

    Noel, Vincent; Chepfer, Hélène

    2004-01-01

    International audience; The goal of this paper is to retrieve information about ice particle orientation in cirrus clouds. This is achieved by comparing simulations of sunlight reflection on a cirrus cloud with measurements of polarized radiances from the spaceborne instrument Polarization and Directionality of the Earth's Reflectance (POLDER-1) on Advanced Earth Observing Satellite-1 (ADEOS-1). Results show that horizontal orientation of cr ystals can be spotted by the presence of a local ma...