WorldWideScience

Sample records for coupling anion-exchange column

  1. Using solvent extraction to process nitrate anion exchange column effluents

    International Nuclear Information System (INIS)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses

  2. Using solvent extraction to process nitrate anion exchange column effluents

    Energy Technology Data Exchange (ETDEWEB)

    Yarbro, S.L.

    1987-10-01

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO), a new organophosphorous extractant, and a new centrifugal mixer-settler both recently developed at Argonne were evaluated for their potential use in the recovery of actinides from nitrate anion exchange column effluents. The performance of the extractant was evaluated by measuring the extraction coefficient values as a function of acid and salt concentration. Additional performance parameters include extraction coefficient behavior as a function of the total metal concentration in the organic phase, and comparison of different stripping and organic scrubbing techniques. A simulated effluent stream was used to evaluate the performance of the centrifugal mixer-settlers by comparing experimental and calculated interstage concentration profiles. Both the CMPO extractant and the centrifugal mixer-settlers have potential for processing nitrate column effluents, particularly if the stripping behavior can be improved. Details of the proposed process are presented in the flowsheet and contactor design analyses.

  3. Sample pre-treatment to eliminate cationic methylated arsenic for determining arsenite on an anion-exchange column by high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Huang, Jen-How; Ilgen, Gunter; Decker, Berryinne

    2008-03-17

    Co-elution of cationic methylated arsenic, e.g. arsenobetaine may interfere with the determination of arsenite on the Hamilton PRP-X100 anion-exchange column using a phosphate buffer isocratically. Therefore, a sample pre-treatment method with self-packed AG MP-50 cation-exchange cartridges was proposed, which enables the arsenite determination in samples containing arsenobetaine on a PRP-X100 column using a phosphate buffer (pH 5.6) isocratically. Methylated arsenic, including dimethylarsinic acid, trimethylarsine oxide, tetramethylarsonium ion, arsenobetaine and arsenocholine, with concentrations below 1000microgAsL(-1), may be completely retained in the AG MP-50 cartridge without any changes of arsenite, arsenate and monomethylarsonic acid speciation. Such retention was independent of the pH and matrix. It is proposed to be based on hydrophobic interaction. With the help of AG MP-50 cartridges, 11 arsenic species were detected in fish (DORM-2), mussels (BCR-477) and red algae (Porphyra tenera) in 10min on the PRP-X100 column using a phosphate buffer isocratically. Arsenite was the only minor species (up to 0.9%) among all water extractable arsenic species in fish, mussel and red algae.

  4. Ion chromatographic determination of fluoride and chloride in UO2 using microbore anion exchange columns

    International Nuclear Information System (INIS)

    Kelkar, Anoop; Meena, D.L.; Das, D.K.; Behere, P.G.; Mohd Afzal

    2015-01-01

    Chemical characterization of nuclear fuels is required to ensure that nuclear fuel meets the technical specifications of the fuel. Trace non- metallic impurities like Cl and F is important as they affect clad corrosion. Their effect is more severe in presence of moisture. Chlorine and Fluorine is routinely analysed by ion selective electrode or conventional ion chromatography after pyrohydrolyzing the sample in moist O 2 atmosphere at 950°. Both the technique generates large quantity of liquid waste. Generally 1 ml/min flow rate required for the separation of F - and Cl - in conventional ion-chromatographic separation of F - and Cl - on 4.6- 4.0 mm id analytical column. The waste produced per sample injection is ∼ 30-40 ml with suppressed conductivity detection in ion chromatography. There is a need to reduce this analytical waste in analyzing the radioactive samples for the determination of F - and Cl - . Waste generation could be effectively reduced by using microbore anion exchange analytical column. Present paper describe the use of Metrosep A Supp 16 - 100/2.0 column with Na 2 CO 3 +NaOH mobile phase for the determination of F - and Cl - in UO 2 samples using suppressed conductivity detection

  5. PLUTONIUM LOADING CAPACITY OF REILLEX HPQ ANION EXCHANGE COLUMN - AFS-2 PLUTONIUM FLOWSHEET FOR MOX

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E.; King, W.; O' Rourke, P.

    2012-07-26

    Radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the dependence of column loading performance on the feed composition in the H-Canyon dissolution process for plutonium oxide (PuO{sub 2}) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). These loading experiments show that a representative feed solution containing {approx}5 g Pu/L can be loaded onto Reillex{trademark} HPQ resin from solutions containing 8 M total nitrate and 0.1 M KF provided that the F is complexed with Al to an [Al]/[F] molar ratio range of 1.5-2.0. Lower concentrations of total nitrate and [Al]/[F] molar ratios may still have acceptable performance but were not tested in this study. Loading and washing Pu losses should be relatively low (<1%) for resin loading of up to 60 g Pu/L. Loading above 60 g Pu/L resin is possible, but Pu wash losses will increase such that 10-20% of the additional Pu fed may not be retained by the resin as the resin loading approaches 80 g Pu/L resin.

  6. Simultaneous determination of 13 carbohydrates using high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry.

    Science.gov (United States)

    Zhao, Dan; Feng, Feng; Yuan, Fei; Su, Jin; Cheng, Yan; Wu, Hanqiu; Song, Kun; Nie, Bo; Yu, Lian; Zhang, Feng

    2017-04-01

    A simple, accurate, and highly sensitive method was developed for the determination of 13 carbohydrates in polysaccharide of Spirulina platensis based on high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry. Samples were extracted with deionized water using ultrasonic-assisted extraction, and the ultrasound-assisted extraction conditions were optimized by Box-Behnken design. Then the extracted polysaccharide was hydrolyzed by adding 1 mol/L trifluoroacetic acid before determination by high-performance anion-exchange chromatography coupled with pulsed amperometric detection and confirmed by high-performance anion-exchange chromatography coupled with mass spectrometry. The high-performance anion-exchange chromatography coupled with pulsed amperometric detection method was performed on a CarboPac PA20 column by gradient elution using deionized water, 0.1 mol/L sodium hydroxide solution, and 0.4 mol/L sodium acetate solution. Excellent linearity was observed in the range of 0.05-10 mg/L. The average recoveries ranged from 80.7 to 121.7%. The limits of detection and limits of quantification for 13 carbohydrates were 0.02-0.10 and 0.2-1.2  μg/kg, respectively. The developed method has been successfully applied to ambient samples, and the results indicated that high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry could provide a rapid and accurate method for the simultaneous determination of carbohydrates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Optimized anion exchange column isolation of zirconium-89 ( 89 Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

    Energy Technology Data Exchange (ETDEWEB)

    O’Hara, Matthew J.; Murray, Nathaniel J.; Carter, Jennifer C.; Morrison, Samuel S.

    2018-04-01

    Zirconium-89 (89Zr), produced by the (p,n) reaction from naturally monoisotopic yttrium (natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capture Zr from a load solution that is high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>105) and has been shown to separate Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the performance of the method was evaluated using cyclotron bombarded Y foil targets. The separation method was shown to achieve >95% recovery of the 89Zr present in the foils. The 89Zr eluent, however, was in a chemical matrix not immediately conducive to labeling onto proteins. The main intent of this study was to develop a tandem column 89Zr purification process, wherein the anion exchange column method described here is the first separation in a dual-column purification process.

  8. Separation of gold, palladium and platinum in chromite by anion exchange chromatography for inductively coupled plasma atomic emission spectrometric analysis

    International Nuclear Information System (INIS)

    Choi, Kwang Soon; Lee, Chang Heon; Park, Yeong Jae; Joe, Kih Soo; Kim, Won Ho

    2001-01-01

    A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behavior of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(VI) to Cr(III) by H 2 O 2 . AuCl - 4 retained on the resin column was selectively eluted with acetone- HNO 3 -H 2 O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO 3 . The recovery yield of gold with acetone-HNO 3 -H 2 O was 100.7 ± 2.0 % , and the yields of palladium and platinum with concentrated HCl and HNO 3 were 96.1 ± 1.8% and 96.6 ± 1.3%, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ± 2.2 μg/g and 1.6 ± 0.14 μg/g, respectively. Palladium was not detected

  9. Rapid analysis of carbohydrates in aqueous extracts and hydrolysates of biomass using a carbonate-modified anion-exchange column.

    Science.gov (United States)

    Sevcik, Richard S; Mowery, Richard A; Becker, Christopher; Chambliss, C Kevin

    2011-03-04

    Quantitative liquid-chromatography techniques used to characterize carbohydrates present in biomass samples can suffer from long analysis times, limited analyte resolution, poor stability, or a combination of these factors. The current manuscript details a novel procedure enabling resolution of glucose, xylose, arabinose, galactose, mannose, fructose, and sucrose via isocratic elution in less than 5 min. Equivalent conditions also enable analysis of cellobiose and maltose with a minimal increase in chromatographic run time (ca. 3 and 6 min, respectively). Noted chromatographic performance requires that a commercially available anion-exchange column be modified with carbonate prior to analysis. Analytical performance of a modified column was assessed over a 5-day period via repeated analyses of 4 samples, resulting from aqueous extraction or quantitative saccharification of a potential biofuel feedstock (i.e., corn stover or switchgrass). A simple solid phase extraction procedure was utilized to clean up each sample prior to analysis. Analytical accuracy of the extraction protocol was assessed by evaluation of matrix spike recoveries which typically ranged from 84% to 98%. The instrumental variability of measured concentrations in real samples over the 5-day period was generally less than 5% RSD for all detected analytes, independent of sample type. Finally, it is important to note that the modified column exhibited exceptional stability over approximately 800 injections of biofeedstock-based samples. These data demonstrate that a carbonate-modified anion-exchange column can be employed for rapid determination of carbohydrates in biomass samples of lignocellulosic origin. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Characterisation of brewpub beer carbohydrates using high performance anion exchange chromatography coupled with pulsed amperometric detection.

    Science.gov (United States)

    Arfelli, Giuseppe; Sartini, Elisa

    2014-01-01

    High performance anion exchange chromatography (HPAEC) coupled with pulsed amperometric detection (PAD) was optimised in order to quantify mannose, maltose, maltotriose, maltotetraose, maltopentaose, maltohexaose and maltoheptaose content of beer. The method allows the determination of above mentioned oligosaccharides, in a single chromatographic run, without any pre-treatment. Limit of detection and limit of quantification were suitable for beer. Accuracy and repeatability were good for the entire amount considered. Once optimised HPAEC PAD for the specific matrix, the second goal of this research was to verify the possibility to discriminate beers, depending on their style. The carbohydrates content of brewpub commercial beers was very variable, ranging from 19.3 to 1469mg/L (mannose), 34.5 to 2882mg/L (maltose), 141.9 to 20731mg/L (maltotriose), 168.5 to 7650mg/L (maltotetraose), 20.1 to 2537mg/L (maltopentaose), 22.9 to 3295mg/L (maltohexaose), 8.5 to 2492mg/L (maltoeptaose), even in the same style of beer. However, the carbohydrates content was useful, jointed with other compounds amount, to discriminate different styles of beer. As a matter of fact, principal component analysis put in evidence beer differences considering some fermentation conditions and colour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Plant-Scale Concentration Column Designs for SHINE Target Solution Utilizing AG 1 Anion Exchange Resin

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, Dominique C. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    Argonne is assisting SHINE Medical Technologies (SHINE) in their efforts to develop SHINE, an accelerator-driven process that will utilize a uranyl-sulfate solution for the production of fission product Mo-99. An integral part of the process is the development of a column for the separation and recovery of Mo-99, followed by a concentration column to reduce the product volume from 15-25 L to <1 L. Argonne has collected data from batch studies and breakthrough column experiments to utilize the VERSE (Versatile Reaction Separation) simulation program (Purdue University) to design plant-scale product recovery and concentration processes.

  12. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  13. Anion-exchange high-performance liquid chromatography with post-column detection for the analysis of phytic acid and other inositol phosphates

    Science.gov (United States)

    Rounds, M. A.; Nielsen, S. S.; Mitchell, C. A. (Principal Investigator)

    1993-01-01

    The use of gradient anion-exchange HPLC, with a simple post-column detection system, is described for the separation of myo-inositol phosphates, including "phytic acid" (myo-inositol hexaphosphate). Hexa-, penta-, tetra-, tri- and diphosphate members of this homologous series are clearly resolved within 30 min. This method should facilitate analysis and quantitation of "phytic acid" and other inositol phosphates in plant, food, and soil samples.

  14. Rapid isolation of plutonium in environmental solid samples using sequential injection anion exchange chromatography followed by detection with inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2011-01-01

    is straightforward and less labor intensive as compared with batch-wise anion exchange chromatographic procedures. Besides, the automated method features low consumption of ion-exchanger and reagents for column washing and elution, with the consequent decrease in the generation of acidic waste, thus bearing green...

  15. Optimization of SHINE Process: Design and Verification of Plant-Scale AG 1 Anion-Exchange Concentration Column and Titania Sorbent Pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, Dominique C. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Abdul, Momen [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Rotsch, David A. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Tkac, Peter [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2016-06-01

    Argonne National Laboratory has developed a Mo-recovery and -purification system for the SHINE medical technologies process, which uses a uranyl sulfate solution for the accelerator-driven production of Mo-99. The objective of this effort is to reduce the processing time for the acidification of the Mo-99 product prior to loading onto a concentration column and concentration of the Mo-99 product solution. Two methods were investigated: (1) the replacement of the titania concentration column by an anion-exchange column to decrease processing time and increase the radioiodine-decontamination efficiency and (2) pretreatment of the titania sorbent to improve its effectiveness for the Mo-recovery and -concentration columns. Promising results are reported for both methods.

  16. Pu Anion Exchange Process Intensification

    Energy Technology Data Exchange (ETDEWEB)

    Taylor-Pashow, Kathryn M. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-06

    This research is focused on improving the efficiency of the anion exchange process for purifying plutonium. While initially focused on plutonium, the technology could also be applied to other ion-exchange processes. Work in FY17 focused on the improvement and optimization of porous foam columns that were initially developed in FY16. These foam columns were surface functionalized with poly(4-vinylpyridine) (PVP) to provide the Pu specific anion-exchange sites. Two different polymerization methods were explored for maximizing the surface functionalization with the PVP. The open-celled polymeric foams have large open pores and large surface areas available for sorption. The fluid passes through the large open pores of this material, allowing convection to be the dominant mechanism by which mass transport takes place. These materials generally have very low densities, open-celled structures with high cell interconnectivity, small cell sizes, uniform cell size distributions, and high structural integrity. These porous foam columns provide advantages over the typical porous resin beads by eliminating the slow diffusion through resin beads, making the anion-exchange sites easily accessible on the foam surfaces. The best performing samples exceeded the Pu capacity of the commercially available resin, and also offered the advantage of sharper elution profiles, resulting in a more concentrated product, with less loss of material to the dilute heads and tails cuts. An alternate approach to improving the efficiency of this process was also explored through the development of a microchannel array system for performing the anion exchange.

  17. Preparation of quaternary amine monolithic column for strong anion-exchange chromatography and its application to the separation of Enterovirus 71.

    Science.gov (United States)

    Gu, Huimin; Yin, Dezhong; Ren, Jie; Zhang, Baoliang; Zhang, Qiuyu

    2016-10-15

    Large size virion is unable to diffuse into pores of conventional porous chromatography particles. Therefore, separation of virion by conventional column-packing materials is not quite efficient. To solve this problem, a monolithic column with large convective pores and quaternary amine groups was prepared and was applied to separate Enterovirus 71 (EV71, ≈5700-6000kDa). Cross-section, pore structure, hydrodynamic performance, adsorption property and dynamic binding capacity of prepared monolithic column were determined. Double-pore structures, macropore at 2472nm and mesopore at 5-60nm, were formed. The porosity was up to 63.3%, which enable higher permeability and lower back pressure of the monolithic column than commercial UNO™ Q1 column. Based on the breakthrough curves, the loading capacity of bovine serum albumin was calculated to be 42.0mg per column. In addition, prepared quaternary amine monolithic column was proved to be suitable for the separation of protein mixture by strong anion-exchange chromatography. As a practical application, prepared monolith column presents excellent performance to the separation of EV71 from virus-proteins mixture. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. P61-S Multidimensional Liquid Chromatography of Proteins Using Monolithic Weak Anion Exchange and Reversed-Phase Columns

    OpenAIRE

    Sneekes, E.; van Ling, R.; de Haan, B.; Dolman, B.; Swart, R.; van Gils, M.

    2007-01-01

    Recent developments in monolithic column technology have yielded significant improvements in the biopolymer analysis field. Monolithic columns offer several advantages over particulate columns due to their macroporous structure, which provides fast mass transfer, low back pressure and high resolution. Polystyrene divinylbenzene (PS-DVB) monolithic columns are chemically inert; they offer high pH stability and excellent chromatographic performance in reversed-phase LC. While the application of...

  19. Removal efficiency of multiple poly- and perfluoroalkyl substances (PFASs) in drinking water using granular activated carbon (GAC) and anion exchange (AE) column tests.

    Science.gov (United States)

    McCleaf, Philip; Englund, Sophie; Östlund, Anna; Lindegren, Klara; Wiberg, Karin; Ahrens, Lutz

    2017-09-01

    Poly- and perfluoroalkyl substances (PFASs) have been detected in drinking water at relatively high concentrations throughout the world which has led to implementation of regulatory guidelines for specific PFASs in drinking water in several European countries and in the U.S. The Swedish National Food Agency has determined that the drinking water of over one third of the country's municipal consumers is at risk or already affected by PFAS contamination. The present study investigated the effects of perfluorocarbon chain length, functional group and isomer structure (branched or linear) on removal of multiple PFASs using granular activated carbon (GAC, Filtrasorb ® 400) and anion exchange (AE, Purolite ® A600) column experiments. The removal of 14 different PFASs, i.e. the C 3 C 11 , C 14 perfluoroalkyl carboxylic acids (PFCAs) (PFBA, PFPeA, PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, PFDoDA, PFTeDA), perfluorooctane sulfonamide (FOSA), and the C 4 , C 6 , C 8 perfluoroalkyl sulfonic acids (PFSAs) (PFBS, PFHxS, PFOS), was monitored for a 217 day period. The results indicate the selective nature of PFAS removal as the absorbents are loaded with PFASs and dissolved organic carbon (DOC). A clear relationship between perfluorocarbon chain length and removal efficiency of PFASs using GAC and AE was found while PFASs with sulfonate functional groups displayed greater removal efficiency than those with carboxylate groups. Similarly, time to column breakthrough increased with increasing perfluorocarbon chain length and was greater for the PFSAs than the PFCAs for both GAC and AE. Shorter carbon chained PFASs such as PFBA, PFPeA, PFHxA showed desorption behavior and long-chained PFASs showed increased removal towards the end of the experiment indicating agglomeration or micelle development. Linear isomers of PFOS, PFHxS, and perfluorooctane sulfonamide (FOSA) had greater column removal efficiencies using GAC (and also for AE at greater bed volume throughput) than the branched

  20. Modacrylic anion-exchange fibers for Cr(VI) removal from chromium-plating rinse water in batch and flow-through column experiments.

    Science.gov (United States)

    Lee, Seung-Chan; Kang, Jin-Kyu; Sim, Eun-Hye; Choi, Nag-Choul; Kim, Song-Bae

    2017-11-10

    The aim of this study was to investigate Cr(VI) removal from chromium-plating rinse water using modacrylic anion-exchange fibers (KaracaronTM KC31). Batch experiments were performed with synthetic Cr(VI) solutions to characterize the KC31 fibers in Cr(VI) removal. Cr(VI) removal by the fibers was affected by solution pH; the Cr(VI) removal capacity was the highest at pH 2 and decreased gradually with a pH increase from 2 to 12. In regeneration and reuse experiments, the Cr(VI) removal capacity remained above 37.0 mg g -1 over five adsorption-desorption cycles, demonstrating that the fibers could be successfully regenerated with NaCl solution and reused. The maximum Cr(VI) removal capacity was determined to be 250.3 mg g -1 from the Langmuir model. In Fourier-transform infrared spectra, a Cr = O peak newly appeared at 897 cm -1 after Cr(VI) removal, whereas a Cr-O peak was detected at 772 cm -1 due to the association of Cr(VI) ions with ion-exchange sites. X-ray photoelectron spectroscopy analyses demonstrated that Cr(VI) was partially reduced to Cr(III) after the ion exchange on the surfaces of the fibers. Batch experiments with chromium-plating rinse water (Cr(VI) concentration = 1178.8 mg L -1 ) showed that the fibers had a Cr(VI) removal capacity of 28.1-186.4 mg g -1 under the given conditions (fiber dose = 1-10 g L -1 ). Column experiments (column length = 10 cm, inner diameter = 2.5 cm) were conducted to examine Cr(VI) removal from chromium-plating rinse water by the fibers under flow-through column conditions. The Cr(VI) removal capacities for the fibers at flow rates of 0.5 and 1.0 mL min -1 were 214.8 and 171.5 mg g -1 , respectively. This study demonstrates that KC31 fibers are effective in the removal of Cr(VI) ions from chromium-plating rinse water.

  1. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  2. Application of the two-film theory to the determination of mass transfer coefficients for bovine serum albumin on anion-exchange columns

    DEFF Research Database (Denmark)

    Hansen, Ernst; Mollerup, Jørgen

    1999-01-01

    by fitting the two film model to the experimentally determined flux. The two film model is compared with two apparent over-all driving force models: The apparent over-all mobile phase driving force model and the apparent over-all solid phase driving force model. The experiments show that the apparent over......-all driving force models fail to describe the flux correctly and this is substantiated by the theory. Results obtained with BSA on the anion exchange media Q HyperD, Source, and Poros show that the external film resistance is significant for Reynolds numbers less than one. The experimental Sherwood numbers...

  3. Sorption of Pb(II) onto a mixture of algae waste biomass and anion exchanger resin in a packed-bed column.

    Science.gov (United States)

    Bulgariu, Dumitru; Bulgariu, Laura

    2013-02-01

    Sorption of Pb(II) was studied by using a biosorbent mixture of algae waste biomass and Purolite A-100 resin in a packed-bed column. Mixing these two components was done to prevent the clogging of the column and to ensure adequate flow rates. Increasing of solution flow rate and initial Pb(II) concentration make that the breakthrough and saturation points to be attained earlier. The experimental breakthrough curves were modeled using Bohart-Adams, Thomas and Yoon-Nelson models, and the parameters for all these models were calculated. A regeneration efficiency of 98% was achieved using 0.1 mol L(-1) HCl and not significant changes in lead uptake capacity after three biosorption/desorption cycles were noted. The biosorbent mixture was able to remove Pb(II) from synthetic wastewater at pH 5.0 and flow rate of 3.5 mL min(-1), and the obtained effluent has better quality characteristics. The biosorbent mixture it is suitable for a continuous system for large-scale applications. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Test procedure for anion exchange chromatography

    International Nuclear Information System (INIS)

    Cooper, T.D.

    1994-01-01

    Plutonium from stored nitrate solutions will be sorbed onto anion exchange resins and converted to storable plutonium dioxide. Useful information will be simultaneously gained on the thermal stability and ion exchange capacity of four commercially available anion exchange resins over several years and under severe degradative conditions. This information will prove useful in predicting the safe and efficient lifetimes of these resins

  5. Development of anion-exchange/reversed-phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry methods for the speciation of bio-available iodine and bromine from edible seaweed.

    Science.gov (United States)

    Romarís-Hortas, Vanessa; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2012-05-04

    Anion exchange high performance liquid chromatography hyphenated with inductively coupled plasma-mass spectrometry has been novelly applied to assess inorganic (iodide and iodate) and organic (3-iodotyrosine - MIT, and 3,5-diiodotyrosine - DIT) iodine species in a single chromatographic run. The optimized operating conditions (Dionex IonPac AS7, gradient elution with 175 mM ammonium nitrate plus 15% (v/v) methanol, pH 3.8, as a mobile phase and flow rates within the 0.5-1.5 mL min(-1) range) have also been used to perform inorganic bromine speciation analysis (bromide and bromate). The developed method has been applied for determining the bio-available contents of iodine and bromine species in dialyzates from edible seaweed. Reverse phase high performance liquid chromatography (Zorbax Eclipse XDB-C8, gradient elution with 0.2% (m/m) acetic acid, and 0.2% (m/m) acetic acid in methanol, as mobile phases, and a constant flow rate of 0.75 mL min(-1)) also hyphenated with inductively coupled plasma-mass spectrometry was used to confirm the presence of organic iodine species (MIT and DIT) in the dialyzates. The verification of the presence of iodinated amino acids (MIT and DIT) in the extracts was also performed by reverse phase high performance liquid chromatography-electrospray ionization-mass spectrometry (LTQ Orbitrap). The developed methods have provided good repeatability (RSD values lower than 10% for both anion exchange and reverse phase separations) and analytical recoveries within the 90-105% range for all cases. The in vitro bio-availability method consisted of a simulated gastric and an intestinal digestion/dialysis (10 kDa molecular weight cut-off - MWCO) two-stage procedure. Iodide and MIT were the main bio-available species quantified, whereas bromide was the major bromine species found in the extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. ANION EXCHANGE METHOD FOR SEPARATION OF METAL VALUES

    Science.gov (United States)

    Hyde, E.K.; Raby, B.A.

    1959-02-10

    A method is described for selectively separating radium, bismuth, poloniums and lead values from a metallic mixture of thc same. The mixture is dissolved in aqueous hydrochloric acid and the acidity is adjusted to between 1 to 2M in hydrochloric acid to form the anionic polychloro complexes of polonium and bismuth. The solution is contacted with a first anion exchange resin such as strong base quaternary ammonia type to selectively absorb the polonium and bismuth leaving the radium and lead in the effluent. The effluent, after treatment in hydrochloric acid to increase the hydrochloric acid concentration to 6M is contacted with a second anion exchange iesin of the same type as the above to selectively adsorb the lead leaving the radium in the effluent. Radium is separately recovered from the effluent from the second exchange column. Lead is stripped from the loaded resin of the second column by treatment with 3M hydrochloric acid solution. The loaded resin of the first column is washed with 8M hydrochloric acid solution to recover bismuth and then treated with strong nitric acid solution to recover polonium.

  7. Computerized mathematical model for the anion exchange processing of plutonium(IV)

    International Nuclear Information System (INIS)

    Navratil, J.D.; Proctor, S.G.; Kirkby, L.L.

    1977-01-01

    A computerized mathematical model for anion exchange processing of plutonium(IV) was adopted from a previously written code. The model was verified to predict, within +-30 percent, a profile of plutonium breakthrough for the sorption process on Dowex 1-X4 anion exchange resin. The program was modified to incorporate column washing and elution logic. Experimental washing and elution data were in satisfactory agreement with predicted data. Provisions for changing the flow rate during the course of a run and for plotting capabilities to aid in better presentation of column breakthrough curves also were incorporated into the model

  8. Separation and determination of alditols and sugars by high-pH anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Andersen, Rikke; Sørensen, A.

    2000-01-01

    Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic-pulsed a......Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic......-pulsed amperometric detection (HPAEC-PAD) method that determines all the polyols used as food additives in food products and the most commonly found mono- and disaccharides on a routine basis. The linearity, repeatability, internal reproducibility and accuracy are described. The applicability of the method has been...

  9. Anion exchange in mixed solvent systems Part 7

    International Nuclear Information System (INIS)

    Koprda, V.

    1976-01-01

    The diffusion of chlorocomplexes of some corrosion and fission products in anion exchange beads has been studied in mixed solvent media. The effects of variables on the kinetics of the exchange process by the batch and flow technique were examined. The strongly basic anion exchanger Dowex 2x8 in its Cl - form was used in organic solvent-water-hydrochloric acid solutions. The dependence of the exchange rate on temperature, the viscosity of the solution, the mean resin particle diameter and the composition of the solution was studied. Film and particle diffusion coefficients were calculated from the experimental data. The results provide valuable data for the design of separation procedures. The most perspective parameters affecting substantially the kinetics of ion exchange and the dynamic behaviour of ionic species in chromatographic column seem to be temperature temperature, viscosity of solution, resin particle diameter and the quantity of organic solvent in mixed solution. The results of the kinetics of chlorocomplexes of trace radionuclides of corrosion and fission products provide valuable data for the design of separation procedures from mixed solvents. (T.G.)

  10. Bicarbonate adsorption band of the chromatography for carbon isotope separation using anion exchangers

    International Nuclear Information System (INIS)

    Takeda, Kunihiko; Obanawa, Heiichiro; Hata, Masahisa; Sato, Katsuya

    1985-01-01

    The equilibria of bicarbonate ion between two phases were studied for the carbon isotope separation using anion exchangers. The condition of the formation of a bicarbonate adsorption band was quantitatively discussed. The formation of the adsorption band depends on the difference of S-potential which is the sum of the standard redection chemical potentials and L-potential which is the sum of the reduction chemical potential. The isotopic separation factor observed was about 1.012, independent of the concentrations of acid and alkali in the solutions. The isotopic separation factor was considered to be determined by the reaction of bicarbonate ion on anion exchangers and carbon dioxide dissolved in solutions. The enriched carbon isotope whose isotopic abundance ratio ( 13 C/ 12 C) was 1.258 was obtained with the column packed with anion exchangers. (author)

  11. Anion-exchange Studies of Radioactive Trace Elements in Sulphuric Acid Solutions

    International Nuclear Information System (INIS)

    Samsahl, K.

    1963-01-01

    As part of a chemical group separation procedure used as a pretreatment in gamma spectrometric analysis, a study has been made of the adsorption from sulphuric acid solutions on strongly basic anion exchange resins, prepared in the hydroxide and the sulphate forms, of trace activities of Na, P, K, Ca, Sc, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Rb, Sr, Zr, Nb, Mo, Tc, Ag, Cd, In, Cs, Ba, La, Ce, Hf, Ta, W, Ir, Pa and Np. Besides adsorbing some of the trace elements in the solution, the anion exchange resin in the hydroxide form will neutralize the bulk of the sulphuric acid. This makes possible the subsequent sequential separation of chloride complexes on short anion-exchange columns by a stepwise increasing of the HCl concentration of the solution. On the basis of the results obtained in the present and earlier experiments, a new improved chemical group-separation procedure for mixtures of radioactive trace elements is outlined

  12. Transesterification of propylene glycol methyl ether in chromatographic reactors using anion exchange resin as a catalyst.

    Science.gov (United States)

    Oh, Jungmin; Sreedhar, Balamurali; Donaldson, Megan E; Frank, Timothy C; Schultz, Alfred K; Bommarius, Andreas S; Kawajiri, Yoshiaki

    2016-09-30

    Reactive chromatography using an anion exchange resin is proposed for a transesterification reaction of propylene glycol methyl ether (DOWANOL™ PM) with ethyl acetate to produce propylene glycol methyl ether acetate (DOWANOL™ PMA). This reaction is studied in batch and chromatographic reactors catalyzed by an anion exchange resin. Several anion exchange resins are tested and compared based on the performance of resin as an adsorbent and a catalyst. A chromatographic column is packed with a selected catalyst, AMBERLITE™ IRA904, and both reaction and chromatographic elution are studied at different temperatures and feed concentrations. The resulting chromatograms are fitted to a mathematical model to obtain adsorption equilibrium and reaction kinetic parameters by the inverse method. Compared to esterification investigated in a previous study, transesterification has advantages such as a higher conversion at lower temperature and easy removal of the byproduct which may lead to higher productivity. Deactivation of anion exchange resins is observed and potential solutions are suggested. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Graphene-coated polymeric anion exchangers for ion chromatography

    International Nuclear Information System (INIS)

    Zhang, Kai; Cao, Minyi; Lou, Chaoyan; Wu, Shuchao; Zhang, Peimin; Zhi, Mingyu; Zhu, Yan

    2017-01-01

    Carbonaceous stationary phases have gained much attention for their peculiar selectivity and robustness. Herein we report the fabrication and application of a graphene-coated polymeric stationary phase for anion exchange chromatography. The graphene-coated particles were fabricated by a facile evaporation-reduction method. These hydrophilic particles were proven appropriate substrates for grafting of hyperbranched condensation polymers (HBCPs) to make pellicular anion exchangers. The new phase was characterized by zeta potentials, Fourier transform infrared spectroscopy, thermogravimetry and scanning electron microscope. Frontal displacement chromatography showed that the capacities of the anion exchangers were tuned by both graphene amount and HBCPs layer count. The chromatographic performance of graphene-coated anion exchangers was demonstrated with separation of inorganic anions, organic acids, carbohydrates and amino acids. Good reproducibility was obtained by consecutive injections, indicating high chemical stability of the coating. - Highlights: • Graphene-coated polymeric particles were fabricated by a facile method. • Hyperbranched condensation polymers (HBCPs) were grafted from graphene-coated particles to make anion exchangers. • Graphene amount and HBCPs layer count had significant effects on the anion exchange capacities. • Separation of diverse anionic analytes on the anion exchangers was demonstrated. • The prepared anion exchangers exhibited high stability.

  14. based anion exchange membrane for alkaline polymer electrolyte

    Indian Academy of Sciences (India)

    Administrator

    Alkaline polymer electrolyte fuel cell; anion exchange membrane; PPO; homogeneous quaterni- zation. 1. Introduction. Presently, alkaline polymer electrolyte fuel cells (APEFCs) using anion exchange membranes have received an immense interest among researchers (Varcoe and Slade. 2005). The advantages of ...

  15. Graphene-coated polymeric anion exchangers for ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Cao, Minyi; Lou, Chaoyan [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China); Wu, Shuchao, E-mail: wushch2002@163.com [Zhejiang Institute of Geology and Mineral Resources, Hangzhou 310007 (China); Zhang, Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China); Zhi, Mingyu [Hangzhou Vocational & Technical College, Hangzhou, 310018 (China); Zhu, Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China)

    2017-06-01

    Carbonaceous stationary phases have gained much attention for their peculiar selectivity and robustness. Herein we report the fabrication and application of a graphene-coated polymeric stationary phase for anion exchange chromatography. The graphene-coated particles were fabricated by a facile evaporation-reduction method. These hydrophilic particles were proven appropriate substrates for grafting of hyperbranched condensation polymers (HBCPs) to make pellicular anion exchangers. The new phase was characterized by zeta potentials, Fourier transform infrared spectroscopy, thermogravimetry and scanning electron microscope. Frontal displacement chromatography showed that the capacities of the anion exchangers were tuned by both graphene amount and HBCPs layer count. The chromatographic performance of graphene-coated anion exchangers was demonstrated with separation of inorganic anions, organic acids, carbohydrates and amino acids. Good reproducibility was obtained by consecutive injections, indicating high chemical stability of the coating. - Highlights: • Graphene-coated polymeric particles were fabricated by a facile method. • Hyperbranched condensation polymers (HBCPs) were grafted from graphene-coated particles to make anion exchangers. • Graphene amount and HBCPs layer count had significant effects on the anion exchange capacities. • Separation of diverse anionic analytes on the anion exchangers was demonstrated. • The prepared anion exchangers exhibited high stability.

  16. Removing uranium from drinking water by metal hydroxides and anion-exchange resin

    International Nuclear Information System (INIS)

    Lee, S.Y.; Bondietti, E.A.

    1983-01-01

    Results of bench-scale testing on uranium removal from a natural water that was chosen as a good representative of uranium-bearing waters indicated that conventional coagulant and lime softening treatment removes more than 85 percent of dissolved uranium (83 μg U/L) when an optimum pH and dosage were provided. A strong base anion-exchange column is a recommended option for the treatment of private well waters containing uranium at higher than desirable levels

  17. Ionic Block Copolymers for Anion Exchange Membranes

    Science.gov (United States)

    Tsai, Tsung-Han; Herbst, Dan; Giffin, Guinevere A.; di Noto, Vito; Witten, Tom; Coughlin, E. Bryan

    2013-03-01

    Anion exchange membrane (AEM) fuel cells have regained interest because it allows the use of non-noble metal catalysts. Until now, most of the studies on AEM were based on random polyelectrolytes. In this work, Poly(vinylbenzyltrimethylammonium bromide)-b- (methylbutylene) ([PVBTMA][Br]-b-PMB) was studied by SAXS, TEM and dielectric spectroscopy to understand the fundamental structure-conductivity relationship of ion transport mechanisms within well-ordered block copolymers. The ionic conductivity and the formation of order structure were dependent on the casting solvent. Higher ion exchange capacity (IEC) of the membranes showed higher conductivity at as IEC values below 1.8mmol/g, as above this, the ionic conductivity decreases due to more water uptake leading to dilution of charge density. The humidity dependence of morphology exhibited the shifting of d-spacing to higher value and the alteration in higher characteristic peak of SAXS plot as the humidity increase from the dry to wet state. This phenomenon can be further explained by a newly developed polymer brush theory. Three ionic conduction pathways with different conduction mechanism within the membranes can be confirmed by broadband electric spectroscopy. US Army MURI (W911NF1010520)

  18. Dynamics of anion exchange of lanthanides in aqueous-organic complexing media

    International Nuclear Information System (INIS)

    Sheveleva, I.V.; Bogatyrev, I.O.

    1987-01-01

    Effect of organic solvents (ethanol, acetone, acetonitrile) on change in kinetic parameters of the anion exchange process (anion-exchange column chromatography) of r.e.e. (europium and gadolinium) in complexing nitric acid media has been studied. It is established that complex LnA 4 anion is the only sorbing form of europium and gadolinium on anionite. When the organic component content of the solution being the same, the dynamic parameters of lanthanide exchange have higher values in aqueous-acetonitrile and aqueous-acetone media in comparison with aqueous-enthanol solutions of nitric acid. Lesser mobility of complex lanthanide anions in aqueous-alcoholic solutions can be explained by stronger solvation in the presence of solvents with higher acceptor properties

  19. Effects of arginine on multimodal anion exchange chromatography.

    Science.gov (United States)

    Hirano, Atsushi; Arakawa, Tsutomu; Kameda, Tomoshi

    2015-12-01

    The effects of arginine on binding and elution properties of a multimodal anion exchanger, Capto adhere, were examined using bovine serum albumin (BSA) and a monoclonal antibody against interleukin-8 (mAb-IL8). Negatively charged BSA was bound to the positively charged Capto adhere and was readily eluted from the column with a stepwise or gradient elution using 1M NaCl at pH 7.0. For heat-treated BSA, small oligomers and remaining monomers were also eluted using a NaCl gradient, whereas larger oligomers required arginine for effective elution. The positively charged mAb-IL8 was bound to Capto adhere at pH 7.0. Arginine was also more effective for elution of the bound mAb-IL8 than was NaCl. The results imply that arginine interacts with the positively charged Capto adhere. The mechanism underlying the interactions of arginine with Capto adhere was examined by calculating the binding free energy between an arginine molecule and a Capto adhere ligand in water through molecular dynamics simulations. The overall affinity of arginine for Capto adhere is attributed to the hydrophobic and π-π interactions between an arginine side chain and the aromatic moiety of the ligand as well as hydrogen bonding between arginine and the ligand hydroxyl group, which may account for the characteristics of protein elution using arginine. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Purification of bacteriophage M13 by anion exchange chromatography.

    Science.gov (United States)

    Monjezi, Razieh; Tey, Beng Ti; Sieo, Chin Chin; Tan, Wen Siang

    2010-07-01

    M13 is a non-lytic filamentous bacteriophage (phage). It has been used widely in phage display technology for displaying foreign peptides, and also for studying macromolecule structures and interactions. Traditionally, this phage has been purified by cesium chloride (CsCl) density gradient ultracentrifugation which is highly laborious and time consuming. In the present study, a simple, rapid and efficient method for the purification of M13 based on anion exchange chromatography was established. A pre-packed SepFast Super Q column connected to a fast protein liquid chromatography (FPLC) system was employed to capture released phages in clarified Escherichia coli fermented broth. An average yield of 74% was obtained from a packed bed mode elution using citrate buffer (pH 4), containing 1.5 M NaCl at 1 ml/min flow rate. The purification process was shortened substantially to less than 2 h from 18 h in the conventional ultracentrifugation method. SDS-PAGE revealed that the purity of particles was comparable to that of CsCl gradient density ultracentrifugation method. Plaque forming assay showed that the purified phages were still infectious. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Modelling the transport of carbonic acid anions through anion-exchange membranes

    International Nuclear Information System (INIS)

    Nikonenko, V.; Lebedev, K.; Manzanares, J.A.; Pourcelly, G.

    2003-01-01

    Electrodiffusion of carbonate and bicarbonate anions through anion-exchange membranes (AEM) is described on the basis of the Nernst-Planck equations taking into account coupled hydrolysis reactions in the external diffusion boundary layers (DBLs) and internal pore solution. The model supposes local electroneutrality as well as chemical and thermodynamic equilibrium. The transport is considered in three layers being an anion exchange membrane and two adjoining diffusion layers. A mechanism of competitive transport of HCO 3 - and CO 3 2- anions through the membrane which takes into account Donnan exclusion of H + ions is proposed. It is predicted that the pH of the depleting solution decreases and that of the concentrating solution increases during electrodialysis (ED). Eventual deviations from local electroneutrality and local chemical equilibrium are discussed

  2. New anion-exchange polymers for improved separations

    International Nuclear Information System (INIS)

    Jarvinen, G.D.; Barr, M.E.; Marsh, S.F.

    1997-01-01

    Objective is to improve the understanding of how the structure of a new class of anion-exchange polymers controls the binding of anionic actinide complexes from solution. This is needed to develop practical separation systems that will reduce the cost of actinide processing operations within the DOE complex. In addition anion exchange is widely used in industry. Several new series of bifunctional anion- exchange polymers have been designed, synthesized, and tested for removing Pu(IV), Am(III), and U(VI) from nitric acid. The polymers contain a pyridinium site derived from the host poly(4-vinylpyridine) and a second cationic site attached through a chain of 2 to 6 methylene groups. The new polymers removed Pu four to ten times more efficiently than the best commercial materials

  3. Anion exchange separation and purification of neodymium from fission products

    International Nuclear Information System (INIS)

    Ramkumar, K.L.; Raman, V.A.; Khodade, P.S.; Jain, H.C.

    1979-01-01

    Neodymium-148, the stable fission product has been proved to be one of the best monitors for the determination of nuclear fuel burn-up using triple spike isotope dilution mass spectrometry. For the precise and accurate determination of neodymium it is essential to separate it from bulk of other materials and purify from cerium and samarium which would otherwise cause isobaric interferences. A single stage anion exchange procedure for the separation and purification of neodymium from fission products has been developed. This method supercedes the lengthy and time consuming two stage anion exchange procedure normally used and ensures good chemical yield. (author)

  4. An anion-exchange chromatographic study on boron isotopic fractionation at 2 MPa at 293 K.

    Science.gov (United States)

    Musashi, Masaaki; Matsuo, Motoyuki; Oi, Takao; Nomura, Masao

    2006-10-27

    To study boron isotopic fractionation at high pressure, column chromatography operated in the breakthrough manner was performed at 2.0 MPa at 25.0 degrees C. The fractionation factor (S) between boron adsorbed onto strongly basic anion-exchange resin and boron in solution was obtained as 1.013, which was smaller than the values at 0.1 MPa (atmospheric pressure) found in literature. The pressure dependence of S was discussed based on the polymerization of boron in the solution and resin phases and on the occurrence of the pressure dependent isotope effect relating to the molar volume changes of boron species upon isotope substitution.

  5. based anion exchange membrane for alkaline polymer electrolyte

    Indian Academy of Sciences (India)

    Administrator

    Abstract. Hydroxyl ion (OH–) conducting anion exchange membranes based on modified poly (phenylene oxide) are fabricated for their application in alkaline polymer electrolyte fuel cells (APEFCs). In the present study, chloromethylation of poly(phenylene oxide) (PPO) is performed by aryl substitution rather than benzyl.

  6. Rejuvenation processes applied to 'poisoned' anion exchangers in uranium processing

    International Nuclear Information System (INIS)

    Gilmore, A.J.

    1979-11-01

    The removal of 'poisons' from anion exchangers in uranium processing of Canadian radioactive ores is commonly called rejuvenation or regeneration. The cost of the ion exchange recovery of uranium is adversely affected by a decrease in the capacity and efficiency of the anion exchangers, due to their being 'poisoned' by silica, elemental sulphur, molybdenum and tetrathionates. These 'poisons' have a high affinity for the anion exchangers, are adsorbed in preference to the uranyl complex, and do not desorb with the reagents used normally in the uranyl desorption phase. The frequency of rejuvenation and the reagents required for rejuvenation are determined by the severity of the 'poisoning' accumulated by the exchanger in contact with the uranium leach liquor. Caustic soda (NaOH) at approximately equal to 18 cents/lb is commonly used to remove uranium anion exchangers of tetrathionate ((S 4 0 6 )/-/-) 'poisons'. A potential saving in operating cost would be of consequence if other reagents, e.g. sodium carbonate (Na 2 CO 3 ) at approximately equal to 3.6 cents/lb or calcium hydroxide (Ca(OH) 2 ) at approximately equal to 1.9 cents/lb, were effective in removing (S 4 0 6 )/-/-) from a 'poisoned' exchanger. A rejuvenation process for a test program was adopted after a perusal of the literature

  7. Evaluation of Some Anionic Exchange Resins as Potential Tablet ...

    African Journals Online (AJOL)

    Starches, clays, gums and hydrophilic cellulosic polymers have historically ... expand such interesting applications to anionic exchange resins ..... Edition, Revised and. Expanded. New York: Marcel Dekker; 1989; pp 75-. 130. 4. Goyanes A, Souto C, Martíínez-Pacheco R. A comparison of chitosan-silica and sodium starch.

  8. Adsorption behavior of benzenesulfonic acid by novel weakly basic anion exchange resins.

    Science.gov (United States)

    Sun, Yue; Zuo, Peng; Luo, Junfen; Singh, Rajendra Prasad

    2017-04-01

    Two novel weakly basic anion exchange resins (SZ-1 and SZ-2) were prepared via the reaction of macroporous chloromethylated polystyrene-divinylbenzene (Cl-PS-DVB) beads with dicyclohexylamine and piperidine, respectively. The physicochemical structures of the resulting resins were characterized using Fourier Transform Infrared Spectroscopy and pore size distribution analysis. The adsorption behavior of SZ-1 and SZ-2 for benzenesulfonic acid (BA) was evaluated, and the common commercial weakly basic anion exchanger D301 was also employed for comparison purpose. Adsorption isotherms and influence of solution pH, temperature and coexisting competitive inorganic salts (Na 2 SO 4 and NaCl) on adsorption behavior were investigated and the optimum desorption agent was obtained. Adsorption isotherms of BA were found to be well represented by the Langmuir model. Thermodynamic parameters involving ΔH, ΔG and ΔS were also calculated and the results indicate that adsorption is an exothermic and spontaneous process. Enhanced selectivity of BA sorption over sulfate on the two novel resins was observed by comparison with the commercial anion exchanger D301. The fact that the tested resins loaded with BA can be efficiently regenerated by NaCl solution indicates the reversible sorption process. From a mechanistic viewpoint, this observation clearly suggests that electrostatic interaction is the predominant adsorption mechanism. Furthermore, results of column tests show that SZ-1 possesses a better adsorption property than D301, which reinforces the feasibility of SZ-1 for potential industrial application. Copyright © 2016. Published by Elsevier B.V.

  9. Design of expanded bed supports for the recovery of plasmid DNA by anion exchange adsorption

    DEFF Research Database (Denmark)

    Theodossiou, Irini; Søndergaard, M.; Thomas, Owen R. T.

    2001-01-01

    and blueprints for improved expanded bed adsorbents have been put forward. The characterisation and testing of small (20-40 mum) high density (>3.7 g cm(-3)) pellicular expanded bed materials functionalised with various anion exchange structures is presented. In studies with calf thymus DNA, dynamic binding...... capacities of 1.2 and 3.4 mg ml(-1) were recorded for prototype diethylaminoethyl-and polyethylene imine-linked adsorbents which were respectively 25 and 70 fold higher than those of equivalently derivatised commercial expanded bed materials. The prototype polyethylene imine-coupled material exhibited severe...

  10. The immobilization of anion exchange resins in polymer modified cements

    International Nuclear Information System (INIS)

    Dyer, A.; Morgan, P.D.

    1991-09-01

    Organic anion exchange resins, loaded with 99-Tc as the pertechnate ion, were incorporated into polymer modified cements (Flexocrete Ltd, Preston). BFS/OPC (9:1 mix) also was modified by three polymers from the same source (styrene acrylic (2) styrene butadiene) and loaded with anion exchanger containing the pertechnate. Composites were tested for initial compressive strengths, under water and radiation stability and leach rate. IAEA standard leach testing was with simulated sea and ground waters. Ground water leaching also was carried out on composites subjected to 1.10 9 rads (γ). Leach testing correlated well with compressive strength. Modified composites performed better than the BFS/OPC mix under all conditions studied and were able to encapsulate higher resin loadings. (author)

  11. Rejuvenation of the anion exchanger used for uranium recovery

    International Nuclear Information System (INIS)

    Yan, T.-Y.; Espenscheid, W.F.

    1986-01-01

    The present invention is directed to improving the performance of strong base anionic exchange resins used in uranium recovery that exhibit an undesirable decrease in loading capacity and in total exchange capacity. The invention comprises treating an anionic exchange resin to remove physically adsorbed and occluded fouling agents and to remove poisons which may be chemically bound to active ion groups on the resin. The process involves treating the resin, after the uranium ion exchange stage, with an alkaline carbonate solution, preferably treating the resin with an acid eluant first. The acid treatment dissolves insoluble fouling agents which are physically occluded or adsorbed by the resin and that the weak base treatment augments that result and probably removes poisons which are physically or chemically bound to the resin

  12. Inorganic anion exchangers for the treatment of radioactive wastes

    International Nuclear Information System (INIS)

    Dyer, A.; Jamil, M.A.

    1987-07-01

    Inorganic anion exchangers are evaluated for Tc, I and S isotope removal from aqueous nuclear waste streams. Chemical, thermal, and radiation stabilities were examined. Selected exchangers were examined in detail for their selectivities, kinetics and mechanism of the sorption process (especially in NO 3 - , OH - and BO 3 - environments). Cement encapsulation and leaching experiments were made on the exchangers showing most promise for 'radwaste' treatment. (author)

  13. Organic resin anion exchangers for the treatment of radioactive wastes

    International Nuclear Information System (INIS)

    Dyer, A.; McGinnes, D.F.

    1988-07-01

    Organic anion exchange resins are evaluated for 99-TcO 4 - (pertechnate) removed from aqueous nuclear waste streams. Chemical, thermal and radiation stabilities were studied. Selected resins were examined in detail for their selectivities in the presence of I - , NO 3 - , SO 4 = , CO 3 = , Cl - and OH - . Ion exchange equilibria and kinetic mechanisms were determined. Preliminary investigations of cement encapsulation in polymer modified form were made and some leach studies carried out. (author)

  14. Characterization of oligosaccharides with capillary high performance anion exchange chromatography hyphenated to pulsed amperometric detection and ion trap mass spectrometry : application to the analysis of human lysosomal disorders

    NARCIS (Netherlands)

    Bruggink, Cornelis

    The development of a capillary ion chromatograph is described together with a matching desalter. This desalter made it possible to use on-line a mass spectrometer. The mass spectrometer enables partly to characterize carbohydrates eluting from the anion exchange column. This separation technology is

  15. An Anion-Exchange Method for the Separation of P-32 Activity in Neutron-Irradiated Biological Material

    International Nuclear Information System (INIS)

    Samsahl, K.

    1964-06-01

    Strong hydrochloric-acid solutions containing small amounts of orthophosphoric and citric acid and radioactive tracers of the elements Na, P, K, Ca, Se, Cr, Mn, Ni, Rb, Sr, Cs, Ba, La, and Ce were titrated with a water suspension of strongly basic anion-exchange resin in the hydroxide form. The titration was carried out to pH = 3.0. It was followed by filtration of the mixture on the top of a small anion-exchange column in the chloride form and a final washing with water. Phosphorus was quantitatively adsorbed by the resin and the scandium retention was better than 96 per cent. The remaining elements passed quantitatively into the effluent, with the exception of nickel, which was adsorbed to a very small extent

  16. Development of nanoscale zirconium molybdate embedded anion exchange resin for selective removal of phosphate.

    Science.gov (United States)

    Bui, Trung Huu; Hong, Sung Pil; Yoon, Jeyong

    2018-05-01

    Development of a selective adsorbent with an enhanced removal efficiency for phosphate from wastewater is urgently needed. Here, a hybrid adsorbent of nanoscale zirconium molybdate embedded in a macroporous anion exchange resin (ZMAE) is proposed for the selective removal of phosphate. The ZMAE consists of a low agglomeration of zirconium molybdate nanoparticles (ZM NPs) dispersed within the structure of the anion exchange (AE) resin. As major results, the phosphate adsorption capacity of the ZMAE (26.1 mg-P/g) in the presence of excess sulfate (5 mM) is superior to that of the pristine AE resin (1.8 mg-P/g) although their phosphate uptake capacity was similar in the absence of sulfate and these results were supported by the high selectivity coefficient of the ZMAE toward phosphate over sulfate (S PO4/SO4 ) more than 100 times compared to the pristine AE resin. This superior selective performance of the ZMAE for phosphate in the presence of sulfate ions is well explained by the role of the ZM NPs that contributed to 69% of the phosphate capacity which is based on an observation that the phosphate adsorption capacity of the ZM NPs is not affected by the presence of sulfate. In addition, the behavior of the selective phosphate removal by the ZMAE was well demonstrated by not only in the batch mode experiment with simulated Mekong river water and representative wastewater effluent but also in a column test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Use of the miniature anion exchange centrifugation technique to isolate Trypanosoma evansi from goats.

    Science.gov (United States)

    Gutierrez, Carlos; Corbera, Juan A; Doreste, Francisco; Büscher, Philippe

    2004-10-01

    DEAE (anion exchanger diethylaminoethyl)-cellulose and mini Anion Exchange Centrifugation Technique (mAECT) allow salivarian trypanosomes to be separated from the blood of affected animals. The purpose of this study was to assess the mAECT in goats infected with T. evansi. Five adult Canary goats were inoculated intravenously with at least 1 x 10(5) T. evansi isolated from a dromedary camel in the Canary Islands. The goats were monitored for specific antibodies and parasite detection. The inoculated goats became infected and the parasitemia remained very low but was persistent. For mAECT columns, the DEAE gel was equilibrated with phosphate-buffered saline glucose. T. evansi was detected by its mobility with a microscope at low magnification (10 x 10). The mAECT proved to be more sensitive than blood smear and buffy coat but less sensitive than mouse inoculation. We conclude that in cases of very low parasitemia in goats, mAECT can be used when other parasite-detection tests have failed.

  18. Radio-iodide uptake by modified poly (glycidyl methacrylate) as anion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Sameh H. [Atomic Energy Authority, Cairo (Egypt). Nuclear Research Center; Atomic Energy Authority, Cairo (Egypt). Second Research Reactor; Elbarbary, Ahmed M. [Atomic Energy Authority, Cairo (Egypt). Radiation Research of Polymer Chemistry Dept.; Rashad, Ghada; Fasih, T.W. [Atomic Energy Authority, Cairo (Egypt). Hot Laboratories Center

    2017-03-01

    Poly(glycidyl methacrylate) (PGMA) microspheres were prepared by radiation induced polymerization of glycidyl methacrylate (GMA) monomer. The factors affecting the degree of polymerization and yield (%) of PGMA such as type of solvent, monomer concentration, and irradiation dose were investigated. It was found that the PGMA yield (%) increases with increasing monomer concentration up to 50% and absorbed dose of 5 kGy. The resulting PGMA containing the epoxy group was chemically modified by hydroxyl amine to act as anion-exchange resin for uptake of {sup 131}I{sup -} ions. The modified PGMA (MPGMA) was characterized by Fourier transform infrared (FT-IR) spectrophotometer, thermal gravimetric analysis (TGA) and scanning electron microscopy (SEM). I-131 is produced from the fission of U-235 with low-enrichment uranium (LEU) targets in the Egyptian Second Research Reactor (ETRR-2). Separation of iodide from the radioactive solution by batchwise and column techniques was employed to determine the adsorption capacity of the MPGMA. Quality control of {sup 131}I product solution and radiochemical purity was examined by using the ascending paper chromatography method. The uptake behavior of MPGMA towards {sup 131}I{sup -} ions were studied at different experimental conditions and achieved by X-ray fluorescence (XRF). The synthesized MPGMA showed good results as anion-exchange and an effective adsorbent for uptaking {sup 131}I{sup -} ions.

  19. Reducing nitrogen crossover in microbial reverse-electrodialysis cells by using adjacent anion exchange membranes and anion exchange resin

    KAUST Repository

    Wallack, Maxwell J.

    2015-01-01

    Microbial reverse electrodialysis cells (MRECs) combine power generation from salinity gradient energy using reverse electrodialysis (RED), with power generation from organic matter using a microbial fuel cell. Waste heat can be used to distill ammonium bicarbonate into high (HC) and low salt concentration (LC) solutions for use in the RED stack, but nitrogen crossover into the anode chamber must be minimized to avoid ammonia loses, and foster a healthy microbial community. To reduce nitrogen crossover, an additional low concentration (LC) chamber was inserted before the anode using an additional anion exchange membrane (AEM) next to another AEM, and filled with different amounts of anion or cation ion exchange resins. Addition of the extra AEM increased the ohmic resistance of the test RED stack from 103 Ω cm2 (1 AEM) to 295 Ω cm2 (2 AEMs). However, the use of the anion exchange resin decreased the solution resistance of the LC chamber by 74% (637 Ω cm2, no resin; 166 Ω cm2 with resin). Nitrogen crossover into the anode chamber was reduced by up to 97% using 50% of the chamber filled with an anion exchange resin compared to the control (no additional chamber). The added resistance contributed by the use of the additional LC chamber could be compensated for by using additional LC and HC membrane pairs in the RED stack.

  20. Evaluating of arsenic(V) removal from water by weak-base anion exchange adsorbents.

    Science.gov (United States)

    Awual, M Rabiul; Hossain, M Amran; Shenashen, M A; Yaita, Tsuyoshi; Suzuki, Shinichi; Jyo, Akinori

    2013-01-01

    Arsenic contamination of groundwater has been called the largest mass poisoning calamity in human history and creates severe health problems. The effective adsorbents are imperative in response to the widespread removal of toxic arsenic exposure through drinking water. Evaluation of arsenic(V) removal from water by weak-base anion exchange adsorbents was studied in this paper, aiming at the determination of the effects of pH, competing anions, and feed flow rates to improvement on remediation. Two types of weak-base adsorbents were used to evaluate arsenic(V) removal efficiency both in batch and column approaches. Anion selectivity was determined by both adsorbents in batch method as equilibrium As(V) adsorption capacities. Column studies were performed in fixed-bed experiments using both adsorbent packed columns, and kinetic performance was dependent on the feed flow rate and competing anions. The weak-base adsorbents clarified that these are selective to arsenic(V) over competition of chloride, nitrate, and sulfate anions. The solution pH played an important role in arsenic(V) removal, and a higher pH can cause lower adsorption capacities. A low concentration level of arsenic(V) was also removed by these adsorbents even at a high flow rate of 250-350 h(-1). Adsorbed arsenic(V) was quantitatively eluted with 1 M HCl acid and regenerated into hydrochloride form simultaneously for the next adsorption operation after rinsing with water. The weak-base anion exchange adsorbents are to be an effective means to remove arsenic(V) from drinking water. The fast adsorption rate and the excellent adsorption capacity in the neutral pH range will render this removal technique attractive in practical use in chemical industry.

  1. Anion Exchange Membranes: Current Status and Moving Forward

    Energy Technology Data Exchange (ETDEWEB)

    Hickner, MA; Herring, AM; Coughlin, EB

    2013-10-29

    This short review is meant to provide the reader with highlights in anion exchange membrane research, describe current needs in the field, and point out promising directions for future work. Anion exchange membranes (AEMs) provide one possible route to low platinum or platinum-free fuel cells with the potential for facile oxidation of complex fuels beyond hydrogen and methanol. AEMs and related stable cationic polymers also have applications in energy storage and other electrochemical technologies such as water electrolyzers and redox flow batteries. While anion exchange membranes have been known for a long time in water treatment applications, materials for electrochemical technology with robust mechanical properties in thin film format have only recently become more widely available. High hydroxide and bicarbonate anion conductivity have been demonstrated in a range of AEM formats, but intrinsic stability of the polymers and demonstration of long device lifetime remain major roadblocks. Novel approaches to stable materials have focused on new types of cations that employ delocalization and steric shielding of the positive center to mitigate nucleophilic attack by hydroxide. A number of promising polymer backbones and membrane architectures have been identified, but limited device testing and a lack of understanding of the degradation mechanisms in operating devices is slowing progress on engineered systems with alkaline fuel cell technology. Our objective is to spur more research in this area to develop fuel cell systems that approach the costs of inexpensive batteries for large-scale applications. (c) 2013 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2013, 51, 1727-1735, 2013

  2. A study of model systems in anionic exchange

    International Nuclear Information System (INIS)

    Haegele, R.; Boeyens, J.C.A.

    1977-01-01

    Preliminary experiments are reported on the preparation and characterization of anionic sulphate and chloride complexes of UO 2+ 2 and iron(III), benzyl-trimethylammonium cation being used as a model substance for the simulation of positive sites in an anionic-exchange resin. The structure of (BTMA) 4 [UO 2 CL 3 -O 2 -CL 3 UO 2 ], a binuclear uranyl-peroxocomplex that has not been reported in the literature, was elucidated by single-crystal x-ray examination, and is described and discussed [af

  3. Uranium extraction from sulfuric acid solution using anion exchange resin

    International Nuclear Information System (INIS)

    Sheta, M. E.; Abdel Aal, M. M.; Kandil, A. T.

    2012-12-01

    Uranium is currently recovered from sulfuric acid leach liquor using anion exchange resin as Amberlite IRA 402 (CT). This technology is based on fact that, uranium exists as anionic complexes. This takes place by controlling the pH of the solution, agitation time, temperature and resin to solution ratio (R/S). In this work, batch stirrer tank used for uranium extraction from sulfate medium and after extraction, elution process was done using 1M NaCl solution. After extraction and elution process, the resin was separated from the system and uranium was determined in the solution. (Author)

  4. Alkaline Anion-Exchange Membranes Containing Mobile Ion Shuttles.

    Science.gov (United States)

    Ge, Xiaolin; He, Yubin; Guiver, Michael D; Wu, Liang; Ran, Jin; Yang, Zhengjin; Xu, Tongwen

    2016-05-01

    A new class of alkaline anion-exchange membranes containing mobile ion shuttles is developed. It is achieved by threading ionic linear guests into poly(crown ether) hosts via host-guest molecular interaction. The thermal- and pH-triggered shuttling of ionic linear guests remarkably increases the solvation-shell fluctuations in inactive hydrated hydroxide ion complexes (OH(-) (H2 O)4 ) and accelerates the OH(-) transport. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Determination of iridium in the Bering Sea and Arctic Ocean seawaters by anion exchange preconcentration-neutron activation analysis

    International Nuclear Information System (INIS)

    Li Shihong; Mao Xueying; Chai Zhifang

    2004-01-01

    Anion exchange method is investigated to separate and enrich iridium in seawater by radiotracer 192 Ir. The adsorption of Ir in the resin increases with the decreasing acidity in the 0.05-1.2 mol/L HCl media, The recovery of iridium in pH=1.5 seawater reaches 89% by a single anion-exchange column. The polyethylene container of acidity of pH=1.5 are suitable for storing trace Ir in seawater. An anion exchange preconcentration-neutron activation analysis procedure is developed to determine iridium in seawaters sampled from the Bering Sea and Arctic Ocean at different depth. The reagent blank value of the whole procedures is (0.18-0.20) x 10 -12 g Ir. The iridium concentrations in the Bering Sea and Arctic Ocean seawater samples are (0.85-3.58) x 10 -12 g/L (0-3504 m) and (1.26-1.97) x 10 -12 g/L (25-1900 m), respectively

  6. Separation of biomolecules by micro-high-performance anion-exchange chromatography using a tentacle-like stationary phase.

    Science.gov (United States)

    Marlin, Nicola Dawn; Smith, Norman William

    2005-05-01

    A variety of biomolecules and their variants, which have previously been problematic to separate, have been analysed using a novel anion-exchange resin based on a non-porous polystyrene polymeric support with a hydrophilic coating and grafted tentacular quaternary ammonium functional groups. The hydrophilic coating results in minimal interaction between the support and the biomolecule, while the highly flexible tentacular-like anion-exchange groups increase the ionic interaction potential and act as an umbrella to hold the proteins away from the surface. Because of the removal of silanophilic interactions, minimisation of hydrophobic interactions, and the highly flexible nature of the tentacle-like ion exchangers, ionic interactions can therefore dominate the separation. As such this phase is highly suited to the separation of highly charged biomolecules and their variants. This polymeric strong anion-exchange (SAX) support was packed into a fused-silica capillary column and, using a salt concentration gradient, various recombinant proteins were analysed by micro-HPLC resulting in baseline resolution.

  7. The determination of Plutonium content in urine using anion exchange resin method

    International Nuclear Information System (INIS)

    Mukh-Syaifudin

    1996-01-01

    The possibility of internal contamination by plutonium is usually determined through urine analysis. The technique involved the co-precipitation of plutonium with rhodizonic acid by the addition of sodium hydroxide, the re-extraction of Pu into concentrated HCl, dissolution of Pu in 8 N HCI + Cl 2 solution, and the purification of plutonium through AGI-X8 anion exchange resin in columns with a diameter of 4 and 7 mm. The eluent was evaporated and the residu was dissolved in 8 N HCI and then deposited directly onto a Lexan slide or electrodeposited onto a stainless steel disc and the alpha emission of Pu was counted by using alpha spectrometry. The results showed that the recoveries of Pu-242 tracer by using column 7 mm and direct deposition and electrodeposition methods were 28.783% and 16.444%, respectively. The recoveries of Pu-242 by using column 4 mm and direct deposition and electrodeposition methods were 64.834% and 55.661%, respectively. From the percentage of recovery, it can be concluded that the direct deposition method was relatively better than the electrodeposition method. The recovery of Pu-242 by using column of 4 mm in diameter was higher than that of column 7 mm

  8. Determination of carbohydrates using pulsed amperometric detection combined with anion exchange separations

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, W.T.; Pohl, C.A.; Rubin, R.

    1987-06-01

    Carbohydrates, including the monosaccharides commonly found in wood and wood pulp hydrolyzates, are separated by anion exchange chromatography using hydroxide and acetate eluants and are determined using pulsed amperometric detection. The detection method is based on oxidizing the sugars in a flow-through electrochemical cell equipped with a gold working electrode. A repeating cycle of three potentials is used: the first to oxidize the carbohydrates and measure the current generated, and two subsequent pulses to clean the electrode surface of oxidation products. The method is fast, sensitive, and requires no pre-column derivatization. It is applied to a sample of hydrolyzed wood pulp, which can be analyzed after minimal sample preparation. Detection limits are of the order of 1 mg/kg for monosaccharides in a 50 micro L injection. (Refs. 8).

  9. Fast kinetic and efficient removal of As(V) from aqueous solution using anion exchange resins

    International Nuclear Information System (INIS)

    Donia, Ahmed M.; Atia, Asem A.; Mabrouk, Dalia H.

    2011-01-01

    Glycidyl methacrylate/methelenebisacrylamide resin with immobilized tetraethylenepentamine ligand was prepared. This pentamine containing resin was transformed to two anion exchange resins through treatment by glycidyl trimethylammonium chloride to give (RI) or hydrochloric acid giving (RII). The resins were used to adsorb As(V) at different experimental conditions using batch and column methods. Kinetics and thermodynamic properties as well as the mechanism of interaction between As(V) and resin active sites were discussed. The maximum adsorption capacities of As(V) on RI and RII were found to be 1.83 and 1.12 mmol/g, respectively. The regeneration and the durability of the loaded resin towards the successive reuse were also investigated.

  10. Quantitative separation of samarium from neodymium by anion exchange chromatography in dilute nitric acid-methanol

    International Nuclear Information System (INIS)

    Strelow, F.W.E.

    1980-01-01

    A method for the separation of trace amounts of the lanthanides into the light and heavy group and for the quantitative separation of Nd and Sm in amounts up to 100mg or more is described. Optimum experimental conditions were determined for the anion exchange column separation. A solution of 0.06M HNO 3 in 85% methanol with a flow rate of 1.0 +- 0.1 mL/min seemed to result in optimum separation of Sm and Nd. Separation of 75.94 mg of Sm from 69.45 mg of Nd by this method was found to result in only 0.01% Sm in the separated Nd and only 0.0005% Nd in the separated Sm

  11. Boron isotope separation by ion exchange chromatography using weakly basic anion exchange resin

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Aida, Masao; Okamoto, Makoto; Kakihana, Hidetake

    1980-01-01

    Isotopic plateau displacement chromatography, a useful method for isotope separation is presented. The boric acid band formed in a column of weakly basic anion exchange resin Diaion WA21 can be eluted with pure water. In order to obtain good accumulation of the isotope effect, a series of experiments with different migration length were carried out. The boron-10 enriched part of the boric acid absorbed band was always preceded by the isotopic plateau part, in which the atomic fraction of boron-10 was maintained at its original value. The atomic fraction of boron-10 at the end of the chromatogram increased with migration length, and in the case of 256-m migration, boron-10 was enriched from its original atomic fraction of 19.84 to 91.00%, the separation factor S being constant irrespective of migration length: S = 1.0100 +- 0.0005. (author)

  12. Rapid separation of plutonium in environmental samples using an anion exchange resin disk

    International Nuclear Information System (INIS)

    Miura, T.; Oikawa, S.; Kishimoto, T.; Banba, S.; Morimoto, T.

    2001-01-01

    A rapid analytical method of Pu in environmental samples by alpha-ray spectrometry and high-resolution inductively coupled plasma mass spectrometer (HR-ICP-MS) using a 3M Empore TM anion exchange resin disk for solid phase extraction has been developed. A trace amount of Pu was quantitatively adsorbed with an Empore TM anion exchange resin disk (47 mm diam.) at a flow rate of 150-200 ml/min from 8 M HNO 3 sample solution. The disk was washed with 10 ml of 8 M HNO 3 and 12 ml of 9 M HCl and then the Pu was quantitatively eluted with 15 ml of 1 M HNO 3 /0.03 M ascorbic acid solution. The time needed to separate Pu from the sample solution with the present method was about 20 minutes. The separated Pu was determined with alpha-ray spectrometry and HR-ICP-MS. The method was applied to the determination of Pu in the certified reference material (IAEA-135) and the environmental soil sample. The analytical results were almost in good agreement with the literature values. (author)

  13. Design and performance evaluation of a microfluidic ion-suppression module for anion-exchange chromatography.

    Science.gov (United States)

    Wouters, Sam; Wouters, Bert; Jespers, Sander; Desmet, Gert; Eghbali, Hamed; Bruggink, Cees; Eeltink, Sebastiaan

    2014-08-15

    A microfluidic membrane suppressor has been constructed to suppress ions of alkaline mobile-phases via an acid-base reaction across a sulfonated poly(tetrafluoroethylene)-based membrane and was evaluated for anion-exchange separations using conductivity detection. The membrane was clamped between two chip substrates, accommodating rectangular microchannels for the eluent and regenerant flow, respectively. Additionally, a clamp-on chip holder has been constructed which allows the alignment and stacking of different chip modules. The response and efficacy of the microfluidic chip suppressor was assessed for a wide range of eluent (KOH) concentrations, using 127 and 183μm thick membranes, while optimizing the flow rate and concentration of the regenerant solution (H2SO4). The optimal operating eluent flow rate was determined at 5μL/min, corresponding to the optimal van-Deemter flow velocity of commercially-available column technology, i.e. a 0.4mm i.d.×250mm long column packed with 7.5μm anion-exchange particles. When equilibrated at 10mM KOH, a 99% decrease in conductivity signal could be obtained within 5min when applying 10mM H2SO4 regenerant at 75μL/min. A background signal as low as 1.2μS/cm was obtained, which equals the performance of a commercially-available electrolytic hollow-fiber suppressor. When increasing the temperature of the membrane suppressor from 15 to 20°C, ion suppression was significantly improved allowing the application of 75mM KOH. The applicability of the chip suppressor has been demonstrated with an isocratic baseline separation of a mixture of seven inorganic ions, yielding plate numbers between 5300 and 10,600 and with a gradient separation of a complex ion mixture. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Review of cell performance in anion exchange membrane fuel cells

    Science.gov (United States)

    Dekel, Dario R.

    2018-01-01

    Anion exchange membrane fuel cells (AEMFCs) have recently received increasing attention since in principle they allow for the use of non-precious metal catalysts, which dramatically reduces the cost per kilowatt of power in fuel cell devices. Until not long ago, the main barrier in the development of AEMFCs was the availability of highly conductive anion exchange membranes (AEMs); however, improvements on this front in the past decade show that newly developed AEMs have already reached high levels of conductivity, leading to satisfactory cell performance. In recent years, a growing number of research studies have reported AEMFC performance results. In the last three years, new records in performance were achieved. Most of the literature reporting cell performance is based on hydrogen-AEMFCs, although an increasing number of studies have also reported the use of fuels others than hydrogen - such as alcohols, non-alcohol C-based fuels, as well as N-based fuels. This article reviews the cell performance and performance stability achieved in AEMFCs through the years since the first reports in the early 2000s.

  15. Anion exchange fractionation of serum proteins versus albumin elimination.

    Science.gov (United States)

    Sahab, Ziad J; Iczkowski, Kenneth A; Sang, Qing-Xiang Amy

    2007-09-01

    Elimination of albumin, constituting more than 50% of total serum proteins, allows increased protein loads on immobilized pH gradient (IPG) gels and better visualization of low-abundance proteins; however, it may result in the loss of albumin-bound low-abundance proteins. In this study, we report the prefractionation of serum proteins by batch anion exchange chromatography into three fractions: one containing proteins with isoelectric points (pI values) higher than the pI of albumin, a second fraction containing proteins with pI values in the same range as the pI of albumin, and a third fraction containing proteins with pI values lower than the pI of albumin. This procedure uses common instrumentation, is carried out under denaturing conditions, and takes less than 30min. We also report the loss of a clinically established prostate cancer serum biomarker, prostate-specific antigen (PSA), after albumin is eliminated using two commercially available albumin elimination kits: one that uses Cibacron Blue F3GA, which achieves albumin depletion through dye-ligand binding, and one that uses specific albumin antibody. The loss of PSA secondary to albumin elimination exceeded that after batch anion exchange serum sample prefractionation.

  16. Size exclusion and anion exchange high performance liquid chromatography for characterizing metals bound to marine dissolved organic matter

    International Nuclear Information System (INIS)

    García-Otero, Natalia; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2013-01-01

    Highlights: ► Fractionation methods for assessing metals bound to marine DOM were developed. ► SEC and AEC with UV detection and hyphenated with inductively coupled plasma-mass spectrometry were used. ► SEC-UV showed marine DOM of molecular weights from 16 to 1 kDa. ► Cobalt, manganese, strontium and zinc are bound to marine DOM. - Abstract: Size exclusion chromatography (SEC) followed by anion exchange chromatography (AEC) hyphenated with inductively coupled plasma-mass spectrometry (ICP-MS) was applied for fractionating metals bound to marine dissolved organic matter (DOM). Surface seawater samples (100 L) were subjected to tangential flow ultrafiltration (10,000 Da cut off) for isolating and pre-concentrating dissolved large molecules. The isolated fraction (retentate) consisted of 1 L, which was further freeze-dried and re-dissolved to 250 mL with ultrapure water. After HI Trap desalting of the re-dissolved retentate, SEC with UV detection showed marine DOM ranging from 6.5 kDa (lower than the permeable volume of the SEC column) to 16 kDa. A further characterization of this fraction by AEC with UV detection revealed the existence of four groups of macromolecules exhibiting retention times of 2.3, 2.8, 4.5 and 14.0 min. AEC hyphenated with ICP-MS showed the presence of strontium and zinc in the first AE fraction isolated from the SEC fraction; while manganese was found to be bound to the second AE fraction. Cobalt was found to be bound to molecules comprising the third AE fraction.

  17. Size exclusion and anion exchange high performance liquid chromatography for characterizing metals bound to marine dissolved organic matter

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Otero, Natalia; Bermejo-Barrera, Pilar [Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, University of Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela (Spain); Moreda-Pineiro, Antonio, E-mail: antonio.moreda@usc.es [Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, University of Santiago de Compostela, Avenida das Ciencias, s/n, 15782 Santiago de Compostela (Spain)

    2013-01-14

    Highlights: Black-Right-Pointing-Pointer Fractionation methods for assessing metals bound to marine DOM were developed. Black-Right-Pointing-Pointer SEC and AEC with UV detection and hyphenated with inductively coupled plasma-mass spectrometry were used. Black-Right-Pointing-Pointer SEC-UV showed marine DOM of molecular weights from 16 to 1 kDa. Black-Right-Pointing-Pointer Cobalt, manganese, strontium and zinc are bound to marine DOM. - Abstract: Size exclusion chromatography (SEC) followed by anion exchange chromatography (AEC) hyphenated with inductively coupled plasma-mass spectrometry (ICP-MS) was applied for fractionating metals bound to marine dissolved organic matter (DOM). Surface seawater samples (100 L) were subjected to tangential flow ultrafiltration (10,000 Da cut off) for isolating and pre-concentrating dissolved large molecules. The isolated fraction (retentate) consisted of 1 L, which was further freeze-dried and re-dissolved to 250 mL with ultrapure water. After HI Trap desalting of the re-dissolved retentate, SEC with UV detection showed marine DOM ranging from 6.5 kDa (lower than the permeable volume of the SEC column) to 16 kDa. A further characterization of this fraction by AEC with UV detection revealed the existence of four groups of macromolecules exhibiting retention times of 2.3, 2.8, 4.5 and 14.0 min. AEC hyphenated with ICP-MS showed the presence of strontium and zinc in the first AE fraction isolated from the SEC fraction; while manganese was found to be bound to the second AE fraction. Cobalt was found to be bound to molecules comprising the third AE fraction.

  18. Removal of 125I from radioactive experimental waste with an anion exchange paper membrane

    International Nuclear Information System (INIS)

    The behavior of radioactive iodide and chloride ions through an anion exchange paper membrane to remove 125 I from radioactive experimental waste has been studied with nonequilibrium thermodynamic analyses. Anion exchange paper membrane was found to be electroconductively more permeable to iodide ion than to chloride ion. The iodide ion bound more strongly to the anion exchange site within a membrane phase than the chloride ion by more than twice. The results suggested that an anion exchange paper membrane was appropriate for the filtration removal system

  19. HB-LINE ANION EXCHANGE PURIFICATION OF AFS-2 PLUTONIUM FOR MOX

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E.; King, W.

    2012-04-25

    Non-radioactive cerium (Ce) and radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the feasibility of using either gadolinium nitrate (Gd) or boric acid (B as H{sub 3}BO{sub 3}) as a neutron poison in the H-Canyon dissolution process. Expected typical concentrations of probable impurities were tested and the removal of these impurities by a decontamination wash was measured. Impurity concentrations are compared to two specifications - designated as Column A or Column B (most restrictive) - proposed for plutonium oxide (PuO{sub 2}) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). Use of Gd as a neutron poison requires a larger volume of wash for the proposed Column A specification. Since boron (B) has a higher proposed specification and is more easily removed by washing, it appears to be the better candidate for use in the H-Canyon dissolution process. Some difficulty was observed in achieving the Column A specification due to the limited effectiveness that the wash step has in removing the residual B after {approx}4 BV's wash. However a combination of the experimental 10 BV's wash results and a calculated DF from the oxalate precipitation process yields an overall DF sufficient to meet the Column A specification. For those impurities (other than B) not removed by 10 BV's of wash, the impurity is either not expected to be present in the feedstock or process, or recommendations have been provided for improvement in the analytical detection/method or validation of calculated results. In summary, boron is recommended as the appropriate neutron poison for H-Canyon dissolution and impurities are expected to meet the Column A specification limits for oxide production in HB-Line.

  20. Spectrophotometric determination of trace niobium in tantalum with sulfochlorophenol S following anion-exchange separation

    International Nuclear Information System (INIS)

    Hashitani, Hiroshi; Adachi, Takeo

    1975-01-01

    A sensitive photometric method for the determination of trace of niobium in tantalum with sulfochlorophenol S is proposed. Tantalum was quantitatively separated by an anion-exchange method from nitric acid-hydrofluoric acid medium. Prior to the color development, these acids were removed by fuming with perchloric acid. Sulfuric acid (0.04 to 0.2M) was necessary for the color development. A maximum absorbance was obtained when the solution was kept for 60 minutes at room temperature, or 5 minutes at 60 0 C. Niobium down to 1 ppm in tantalum can be determined (epsilon=4.2x10 4 ) according to the following procedure. Not more than 1 g of tantalum is dissolved in 8 ml of hydrofluoric acid (1:1) and 2 ml of nitric acid (1:1) by heating. The solution is transferred to a column containing 10 ml of strongly basic anion-exchange resin (Diaion SA No.100) in a polyethylene tube, with three 10-ml portions of a mixture of 1M nitric acid-5M hydrofuluoric acid. Niobium is eluted with 100 ml of a mixture of 5M nitric acid-0.2M hydrofluoric acid. The effluent is evaporated to fumes with 1.5 ml of perchloric acid in the presence of 2 ml of sulfuric acid (1:19). The solution is transferred to a volumetric flask with 5 ml of hydrochloric acid (1:1) and small portions of water. Two ml of 0.05% sulfochlorophenol S solution and 2.5 ml of acetone are then added, and the resulting solution is diluted to 25 ml with water. After 60 minutes, the absorbance is measured at 650 nm with a blank as reference. (auth.)

  1. Highly durable direct hydrazine hydrate anion exchange membrane fuel cell

    Science.gov (United States)

    Sakamoto, Tomokazu; Serov, Alexey; Masuda, Teruyuki; Kamakura, Masaki; Yoshimoto, Koji; Omata, Takuya; Kishi, Hirofumi; Yamaguchi, Susumu; Hori, Akihiro; Horiuchi, Yousuke; Terada, Tomoaki; Artyushkova, Kateryna; Atanassov, Plamen; Tanaka, Hirohisa

    2018-01-01

    The factors influenced on degradation of direct hydrazine hydrate fuel cells (DHFCs) under operation conditions are analyzed by in situ soft X-ray radiography. A durability of DHFCs is significantly improved by multi-step reaction DHFCs (MSR-DHFCs) approach designed to decrease the crossover of liquid fuel. An open circuit voltage (OCV) as well as cell voltage at 5 mA cm-2 of MSR-DHFC construct with commercial anion exchange membrane (AEM) maintained for over of 3500 h at 60 °C. Furthermore, the commercial proton exchange membrane (PEM) is integrated into AEM of MSR-DHFCs resulting in stable power output of MSR-DHFCs for over than 2800 h at 80 °C.

  2. Anion-exchange resin-based desulfurization process

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, A.C.; Strevel, S.D.

    1991-01-01

    The University of Tennessee Space Institute (UTSI) has a Department of Energy grant to further develop the Institute's anion-exchange resin-based flue gas, desulfurization concept. The developmental program proposed includes screening of commercially available resins to select three candidate resins for further study. These three resins will undergo a series of experiments designed to test the resins' performance under different process conditions (including the use of spent MHD seed material). The best of these resins will be used in optimizing the regeneration step and in testing the effects of performance enhancers. The process schematic developed from the results will be used to estimate the related economics.

  3. Efficient Separation of Lanthanides Using Poly (Styrene-Divinyl Benzene) Aminated Anion Exchanger

    International Nuclear Information System (INIS)

    Borai, E.H.; Hassan, R.S.; El- Dessouky, M.I.; Ghonem, A.

    2008-01-01

    New chromatographic method was developed for the determination and separation of lanthanides using AS4A anionic column. The behavior of the column towards lanthanides was studied through many parameters, From the data obtained it is found that, affinity of the column toward investigated ions increase by increasing eluent concentration and it decrease retention factors. With the two investigated eluent (oxalic and citric acids), elution order for lanthanide elements was obtained in their atomic number from La to Lu. Retention times and retention orders obtained at these conditions clearly show that, lanthanides in AS4A are displaced according to anion exchange mechanism. More over separation of lanthanides using AS4A was studied using isocratic and gradient elution programs. Light and the first intermediate lanthanide elements were separated successfully by applying a gradient program containing 70% oxalic acid (100 mM) and 30% water. The problem of separation for heavy and the last intermediate lanthanide elements was solved using 100 mM alpha hydroxy isobutyric acid (α-HIBA)

  4. Fixation of metallic sulfosalicylate complexes on an anionic exchange resin

    International Nuclear Information System (INIS)

    Cahuzac, S.

    1969-06-01

    Since sulfosalicylate ions have acid-base properties, sulfosalicylate complexes have an apparent stability which varies with the ph. As a result, the fixation of sulfo-salicylates on an anionic exchange resin depends on the ph of the solution in equilibrium with the resin. This research has been aimed at studying the influence of the ph on the fixation on an anionic exchange resin (Dowex 1 x 4) of sulfosalicylate anions on the one hand, and of metallic sulfosalicylate complexes on the other hand. In the first part of this work, a determination has been made, by frontal analysis of the distribution of sulfosalicylate ions in the resin according to the total sulfosalicylate I concentration in the aqueous solution in equilibrium with the resin. The exchange constants of these ions between the resin and the solution have been calculated. In the second part, a study has been made of the fixation of anionic sulfosalicylate complexes of Fe(III), Al(III), Cr(III), Cu(II), Ni(II), Co(II), Zn(II), Mn(II), Cd(II), Fe(II) and UO 2 2+ . By measuring the partition coefficients of these different elements between the resin and the solution it has been possible to give interpretation for the modes of fixation of the metallic ions, and to calculate their exchange constant between the resin and the solution. The relationship has been established for each metallic element studied, between its partition coefficient, the ph and the total concentration of the complexing agent in solution. Such a relationship makes it possible to predict, for given conditions, the nature of the species in solution and in the resin, as well as the partition coefficient of a metallic, element. Finally, in the third part of the work, use has been made of results obtained previously, to carry out some separations (Ni 2+ - Co 2+ ; Ni 2+ - Co 2+ - Cu 2+ ; UO 2 2+ - Fe 3+ ; UO 2 2+ - Cr 3+ ; UO 2 2+ - Cu 2+ ; UO 2 2+ - Ni 2+ ; UO 2 2+ - Co 2+ ; UO 2 2+ - Mn 2+ and UO 2 2+ - Cd 2+ ), as well as the purification

  5. Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies

    Science.gov (United States)

    Close, Edward J; Salm, Jeffrey R; Iskra, Timothy; Sørensen, Eva; Bracewell, Daniel G

    2013-01-01

    Fouling of chromatographic resins over their operational lifetimes can be a significant problem for commercial bioseparations. In this article, scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column studies were applied to characterize a case study where fouling had been observed during process development. The fouling was found to occur on an anion exchange (AEX) polishing step following a protein A affinity capture step in a process for the purification of a monoclonal antibody. Fouled resin samples analyzed by SEM and batch uptake experiments indicated that after successive batch cycles, significant blockage of the pores at the resin surface occurred, thereby decreasing the protein uptake rate. Further studies were performed using CLSM to allow temporal and spatial measurements of protein adsorption within the resin, for clean, partially fouled and extensively fouled resin samples. These samples were packed within a miniaturized flowcell and challenged with fluorescently labeled albumin that enabled in situ measurements. The results indicated that the foulant has a significant impact on the kinetics of adsorption, severely decreasing the protein uptake rate, but only results in a minimal decrease in saturation capacity. The impact of the foulant on the kinetics of adsorption was further investigated by loading BSA onto fouled resin over an extended range of flow rates. By decreasing the flow rate during BSA loading, the capacity of the resin was recovered. These data support the hypothesis that the foulant is located on the particle surface, only penetrating the particle to a limited degree. The increased understanding into the nature of the fouling can help in the continued process development of this industrial example. Scanning electron microscopy (SEM), batch uptake experiments, confocal laser scanning microscopy (CLSM) and small-scale column experiments were applied to characterize a

  6. Fixing of metallic acetates on an anion-exchange resin

    International Nuclear Information System (INIS)

    Brigaudeau-Vaissiere, M.

    1966-06-01

    After giving a brief review of the theoretical principles governing the fixation of anionic complexes of metallic elements on an anion exchange resin, we consider the particular case of uranyl acetate. By plotting the partition curves we have been able to calculate the exchange constants in the resin. By studying the changes in the logarithm of the limiting partition coefficient as a function of the logarithm of the free acetate ion concentration, it has been possible to calculate the dissociation constants for the complexes in solution. The fixation of a large number of metallic acetates has been studied. All the tests have been negative except in the case of mercury. For this reason we have been able to consider the possibility of separating uranium from a certain number of elements. Some of these separations are possible even in the presence of interfering anions such as chlorides which have a greater affinity for the resin than have the acetate ions. In the case of water-ethanol and water-isopropanol mixtures, we have improved the conditions under which copper acetate and mercury acetate may be fixed. This study has enabled us to calculate the dissociation constant for the CuAc 3 - complex in the mixtures water +40% (by weight) isopropanol and water +50% (by weight) isopropanol. It should also make it possible to use separation conditions which could not hitherto be applied in aqueous media. (author) [fr

  7. Anion-exchange resin-based desulfurization process

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, A.C.; Strevel, S.D.; Dharmapurikar, R.

    1992-01-01

    Under the current grant, the University of Tennessee Space Institute (UTSI) will carry out the bench scale evaluation and further development of the anion-exchange resin-based desulfurization concept to desulfurize alkali metal sulfates. This concept has been developed and patented by UTSI under US Patent No. 4,917,874. The developmental program proposed under this DOE grant includes screening of commercially available resins to select three candidate resins for further study. These three resins will undergo a series of experiments designed to test the resins' performance under different process conditions (including the use of spent MHD seed material). The best of these resins will be used in optimizing the regeneration step and in testing the effects of performance enhancers. The process schematic developed from the results will be used to estimate the related economics. During this reporting period, October 1, 1991 to September 30, 1992, analysis of batch mode screening experiments was completed to select three candidate resins for process variables study in the fixed-bed set-up. This setup was modified and the experiments were carded out to evaluate effects of major process variables. The analysis of fixed-bed experiments is going on and we have also started simple batch mode experiments to identify desirable conditions for resin regeneration step. We have also started simple process engineering type calculations to determine the trade-off between the solution concentration and the resulting evaporation/concentration load.

  8. A direct ascorbate fuel cell with an anion exchange membrane

    Science.gov (United States)

    Muneeb, Omar; Do, Emily; Tran, Timothy; Boyd, Desiree; Huynh, Michelle; Ghosn, Gregory; Haan, John L.

    2017-05-01

    Ascorbic Acid (Vitamin C) is investigated as a renewable alternative fuel for alkaline direct liquid fuel cells (DLFCs). The environmentally- and biologically-friendly compound, L-ascorbic acid (AA) has been modeled and studied experimentally under acidic fuel cell conditions. In this work, we demonstrate that ascorbic acid is a more efficient fuel in alkaline media than in acidic media. An operating direct ascorbate fuel cell is constructed with the combination of L-ascorbic acid and KOH as the anode fuel, air or oxygen as the oxidant, a polymer anion exchange membrane, metal or carbon black anode materials and metal cathode catalyst. Operation of the fuel cell at 60 °C using 1 M AA and 1 M KOH as the anode fuel and electrolyte, respectively, and oxygen gas at the cathode, produces a maximum power density of 73 mW cm-2, maximum current density of 497 mA cm-2 and an open circuit voltage of 0.90 V. This performance is significantly greater than that of an ascorbic acid fuel cell with a cation exchange membrane, and it is competitive with alkaline DLFCs fueled by alcohols.

  9. Anion exchange membrane fuel cells: Current status and remaining challenges

    Science.gov (United States)

    Gottesfeld, Shimshon; Dekel, Dario R.; Page, Miles; Bae, Chulsung; Yan, Yushan; Zelenay, Piotr; Kim, Yu Seung

    2018-01-01

    The anion exchange membrane fuel cell (AEMFC) is an attractive alternative to acidic proton exchange membrane fuel cells, which to date have required platinum-based catalysts, as well as acid-tolerant stack hardware. The AEMFC could use non-platinum-group metal catalysts and less expensive metal hardware thanks to the high pH of the electrolyte. Over the last decade, substantial progress has been made in improving the performance and durability of the AEMFC through the development of new materials and the optimization of system design and operation conditions. In this perspective article, we describe the current status of AEMFCs as having reached beginning of life performance very close to that of PEMFCs when using ultra-low loadings of Pt, while advancing towards operation on non-platinum-group metal catalysts alone. In the latter sections, we identify the remaining technical challenges, which require further research and development, focusing on the materials and operational factors that critically impact AEMFC performance and/or durability. These perspectives may provide useful insights for the development of next-generation of AEMFCs.

  10. Fouling mitigation of anion exchange membrane by zeta potential control.

    Science.gov (United States)

    Park, Jin-Soo; Lee, Hong-Joo; Choi, Seok-Ju; Geckeler, Kurt E; Cho, Jaeweon; Moon, Seung-Hyeon

    2003-03-15

    The feasibility of fouling mitigation of anion exchange membranes (AEMs) in the presence of humate was studied by adding three different types of water-soluble polymers, i.e., poly(acrylic acid) (PAA), poly(vinyl alcohol) (PVA), and poly(ethylene imine) (PEI), during electrodialysis (ED) desalination. Measurement of zeta potential of the humate used in this study showed highly negative potential (about -30 mV), implying that the humate had a strong fouling potential on the AEMs in ED. Of the three water-soluble polymers, PEI showed a positive zeta potential (about +14 mV) and is able to form an interpolymer complex with the humate. PAA and PVA hardly formed interpolymer complexes with humate due to electrostatic repulsion. The PEI-humate mixture with a volume ratio of 1:20 (PEI:humate) showed zero zeta potential, and a complexed humate with zero surface charge was formed, resulting in no fouling effects on the AEMs. Accordingly, the desalting ED experiments with PEI showed improved ED performance. Further, black colloids formed in the mixture did not cause the cell resistance to increase.

  11. Highly conductive side chain block copolymer anion exchange membranes.

    Science.gov (United States)

    Wang, Lizhu; Hickner, Michael A

    2016-06-28

    Block copolymers based on poly(styrene) having pendent trimethyl styrenylbutyl ammonium (with four carbon ring-ionic group alkyl linkers) or benzyltrimethyl ammonium groups with a methylene bridge between the ring and ionic group were synthesized by reversible addition-fragmentation radical (RAFT) polymerization as anion exchange membranes (AEMs). The C4 side chain polymer showed a 17% increase in Cl(-) conductivity of 33.7 mS cm(-1) compared to the benzyltrimethyl ammonium sample (28.9 mS cm(-1)) under the same conditions (IEC = 3.20 meq. g(-1), hydration number, λ = ∼7.0, cast from DMF/1-propanol (v/v = 3 : 1), relative humidity = 95%). As confirmed by small angle X-ray scattering (SAXS), the side chain block copolymers with tethered ammonium cations showed well-defined lamellar morphologies and a significant reduction in interdomain spacing compared to benzyltrimethyl ammonium containing block copolymers. The chemical stabilities of the block copolymers were evaluated under severe, accelerated conditions, and degradation was observed by (1)H NMR. The block copolymer with C4 side chain trimethyl styrenylbutyl ammonium motifs displayed slightly improved stability compared to that of a benzyltrimethyl ammonium-based AEM at 80 °C in 1 M NaOD aqueous solution for 30 days.

  12. Coupling of column liquid chromatography and Fourier transform infrared spectrometry

    NARCIS (Netherlands)

    Somsen, G.W; Gooijer, C; Velthorst, N.H; Brinkman, U.A Th

    1998-01-01

    This paper provides an extensive overview of the literature on the coupling of column liquid chromatography (LC) and Fourier transform infrared spectrometry (FT-IR). Flow-cell-based FT-IR detection and early solvent-elimination interfaces for LC-FT-IR are discussed in brief. A comprehensive

  13. Model-based analysis of anion-exchanger positioning in direct methanol fuel cell systems

    Science.gov (United States)

    Kraus, Maik; Schröder, Daniel; Krewer, Ulrike

    2014-09-01

    In this work we present a model based study to investigate the presence of anion exchangers in direct methanol fuel cell (DMFC) systems. It is well known that environmental or fuel impurities lead to accumulation of harmful anions, such as chloride, in the system. However, due to DMFC anodic reaction, a carbonate system is present. These corbanate anions have to be taken into account for the anion exchanger design and placement as well as for the system operation strategy with and without anion exchanger, which is the objective of this study. For this purpose, the expected amount of harmful chloride ions in a DMFC system is estimated, and that of carbonate ions is calculated with a model of the carbonate system in a DMFC system. The predicition of durability and dimensions of an anion exchanger is based on a monovalent anion exchange model. The design of gas liquid separators in the DMFC system has a major influence on the amount of dissolved carbon dioxide, which is crucial for durability and dimension of a system integrated anion exchanger. Finally, feasible positions of anion exchanger in a DMFC system are elaborated to fulfill the needs for long term and stable DMFC operation.

  14. Membrane chromatography: protein purification from E. coli lysate using newly designed and commercial anion-exchange stationary phases.

    Science.gov (United States)

    Bhut, Bharat V; Christensen, Kenneth A; Husson, Scott M

    2010-07-23

    This contribution describes the purification of anthrax protective antigen (PA) protein from Escherichia coli lysate using bind-and-elute chromatography with newly designed weak anion-exchange membranes. Protein separation performance of the new AEX membrane adsorber was compared with the commercial Sartobind D membrane adsorber and HiTrap DEAE FF resin column under preparative scale conditions. Dynamic protein binding capacities of all three stationary phases were determined using breakthrough curve analysis. The AEX membrane showed higher binding capacities than the Sartobind D membrane at equivalent volumetric throughput and higher capacities than the HiTrap DEAE FF resin column at 15 times higher volumetric throughput. Anion-exchange chromatography was performed using all three stationary phases to purify PA protein. Quantitative SDS-PAGE analysis of effluent fractions showed that the purity of PA protein was higher for membrane adsorbers than the HiTrap DEAE FF resin column and was the same for the new AEX membrane and Sartobind D membrane adsorbers. The effects of E. coli lysate load volume and volumetric flow rate on PA protein separation resolution using the membrane adsorbers were minor, and the peak elution profile remained un-changed even under conditions where >75% of the total protein dynamic binding capacity of the membranes had been utilized. PA protein peak resolution was higher using pH-gradient elution than with ionic strength gradient elution. Overall, the results clearly demonstrate that membrane chromatography is a high-capacity, high-throughput, high-resolution separation technique, and that resolution in membrane chromatography can be higher than resin column chromatography under preparative conditions and at much higher volumetric throughput. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  15. Ionic Resistance and Permselectivity Tradeoffs in Anion Exchange Membranes

    KAUST Repository

    Geise, Geoffrey M.

    2013-10-23

    Salinity gradient energy technologies, such as reverse electrodialysis (RED) and capacitive mixing based on Donnan potential (Capmix CDP), could help address the global need for noncarbon-based energy. Anion exchange membranes (AEMs) are a key component in these systems, and improved AEMs are needed in order to optimize and extend salinity gradient energy technologies. We measured ionic resistance and permselectivity properties of quaternary ammonium-functionalized AEMs based on poly(sulfone) and poly(phenylene oxide) polymer backbones and developed structure-property relationships between the transport properties and the water content and fixed charge concentration of the membranes. Ion transport and ion exclusion properties depend on the volume fraction of water in the polymer membrane, and the chemical nature of the polymer itself can influence fine-tuning of the transport properties to obtain membranes with other useful properties, such as chemical and dimensional stability. The ionic resistance of the AEMs considered in this study decreased by more than 3 orders of magnitude (i.e., from 3900 to 1.6 Ω m) and the permselectivity decreased by 6% (i.e., from 0.91 to 0.85) as the volume fraction of water in the polymer was varied by a factor of 3.8 (i.e., from 0.1 to 0.38). Water content was used to rationalize a tradeoff relationship between the permselectivity and ionic resistance of these AEMs whereby polymers with higher water content tend to have lower ionic resistance and lower permselectivity. The correlation of ion transport properties with water volume fraction and fixed charge concentration is discussed with emphasis on the importance of considering water volume fraction when interpreting ion transport data. © 2013 American Chemical Society.

  16. Anion-exchange method of ammonium paratungstate production from sodium carbonate solutions

    International Nuclear Information System (INIS)

    Kholmogorov, A.G.; Vaneeva, T.D.; Yurkevich, T.N.

    1978-01-01

    An anion exchange method is suggested for producing ammonium paratungstate from soda solutions for industrial testing. The suggested method allows the process cycle ot be reduced as a result of sorption of tungsten on anionite, followed by desorption of tungsten in form of ammonium tungstate, and by the recovery of the anionite by the solution of a mineral acid. The sorption of tungsten has been carried out in columns having the counter-flow gravitational motion, the desorption in a suspended layer of ionite. It has been established that for the sorption of tungsten it is desirable to use AN-80 P anionite, and that it is expedient to carry out the process with the use of solutions having pH=4 to 2.5. The apparatus flowsheet is presented of an enlarged setup for the production of ammonium paratugstate from the solutions of sodium tungstate. As compared with the deposition method, an increase in the yield of tungsten is achieved by a value of 1.3 to 1.5%. The economical efficiency of the developed method amounts to about 330 rubles per ton of tungsten anhydride

  17. Perchlorate adsorption and desorption on activated carbon and anion exchange resin.

    Science.gov (United States)

    Yoon, In-Ho; Meng, Xiaoguang; Wang, Chao; Kim, Kyoung-Woong; Bang, Sunbaek; Choe, Eunyoung; Lippincott, Lee

    2009-05-15

    The mechanisms of perchlorate adsorption on activated carbon (AC) and anion exchange resin (SR-7 resin) were investigated using Raman, FTIR, and zeta potential analyses. Batch adsorption and desorption results demonstrated that the adsorption of perchlorate by AC and SR-7 resin was reversible. The reversibility of perchlorate adsorption by the resin was also proved by column regeneration test. Solution pH significantly affected perchlorate adsorption and the zeta potential of AC, while it did not influence perchlorate adsorption and the zeta potential of resin. Zeta potential measurements showed that perchlorate was adsorbed on the negatively charged AC surface. Raman spectra indicated the adsorption resulted in an obvious position shift of the perchlorate peak, suggesting that perchlorate was associated with functional groups on AC at neutral pH through interactions stronger than electrostatic interaction. The adsorbed perchlorate on the resin exhibited a Raman peak at similar position as the aqueous perchlorate, indicating that perchlorate was adsorbed on the resin through electrostatic attraction between the anion and positively charged surface sites.

  18. Hydrothermal carbon nanosphere-based agglomerated anion exchanger for ion chromatography.

    Science.gov (United States)

    Zhao, Qiming; Wu, Shuchao; Zhang, Kai; Lou, Chaoyan; Zhang, Peiming; Zhu, Yan

    2016-10-14

    This work reports the application of hydrothermal carbon nanospheres (HCNSs) as stationary phases in ion chromatography. HCNSs were facilely quaternized through polycondensation of methylamine and 1,4-butanediol diglycidyl ether. The quaternization was confirmed by Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. Owing to the electrostatic interaction, quaternized HCNSs were equably attached onto the surface of sulfonated polystyrene-divinylbenzene (PS-DVB) beads to construct the anion exchangers. The aggregation was verified by scanning electron microscopy and elemental analysis. Common anions, aliphatic monocarboxylic acids, polarizable anions, and aromatic acids were well separated on the stationary phases with good stability and symmetry. The prepared column was further applied to detect phosphate content in Cola drink samples. The limit of detection (S/N=3) was 0.09mg/L, and the relative standard deviation (n=10) of retention time was 0.31%. The average recovery was 99.58%. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Effect of Oxalate on the Recycle of Neptunium Filtrate Solution by Anion Exchange

    Energy Technology Data Exchange (ETDEWEB)

    Kyser, E

    2004-11-18

    A series of laboratory column runs has been performed that demonstrates the recovery of neptunium (Np) containing up to 0.05 M oxalate. Np losses were generally less than one percent to the raffinate for feed solutions that contained 2 to 10 g Np/L. Up to 16 percent Np losses were observed with lower Np feed concentrations, but those losses were attributed to the shortened residence times rather than the higher oxalate to Np ratios. Losses in the plant are expected to be significantly less due to the lower cross-section flowrate possible with existing plant pumps. Elimination of the permanganate treatment of filtrates appears to be reasonable since the amount of Np in those filtrates does not appear to be practical to recover. Combination of untreated filtrates with other actinide rich solutions is not advisable as precipitation problems are likely. If untreated filtrates are kept segregated from other actinide rich streams, the recovery of the remaining Np is probably still possible, but could be limited due to the excessively high oxalate to Np ratio. The persistence of hydrazine/hydrazoic acid in filtrate solutions dictates that the nitrite treatment be retained to eliminate those species from the filtrates prior to transfer to the canyon. Elimination of the permanganate treatment of precipitator flushes and recovery by anion exchange does not appear to be limited by the oxalate effect on anion exchange. Np from solutions with higher oxalate to Np molar ratios than expected in precipitator flushes was recovered with low to modest losses. Solubility problems appear to be unlikely when the moles of oxalate involved are less than the total number of moles of Np due to complexation effects. The presence of significant concentrations of iron (Fe) in the solutions will further decrease the probability of Np oxalate precipitation due the formation of Fe oxalate complexes. Np oxalate solubility data in 8 M HNO{sub 3} with from one to six times as much oxalate as Np have

  20. Sorption of Pu(IV) from nitric acid by bifunctional anion-exchange resins

    International Nuclear Information System (INIS)

    Bartsch, R.A.; Zhang, Z.Y.; Elshani, S.; Zhao, W.; Jarvinen, G.D.; Barr, M.E.; Marsh, S.F.; Chamberlin, R.M.

    1999-01-01

    Anion exchange is attractive for separating plutonium because the Pu(IV) nitrate complex is very strongly sorbed and few other metal ions form competing anionic nitrate complexes. The major disadvantage of this process has been the unusually slow rate at which the Pu(IV) nitrate complex is sorbed by the resin. The paper summarizes the concept of bifunctional anion-exchange resins, proposed mechanism for Pu(IV) sorption, synthesis of the alkylating agent, calculation of K d values from Pu(IV) sorption results, and conclusions from the study of Pu(IV) sorption from 7M nitric acid by macroporous anion-exchange resins including level of crosslinking, level of alkylation, length of spacer, and bifunctional vs. monofunctional anion-exchange resins

  1. Hybrid capacitive deionization with anion-exchange membranes for lithium extraction

    OpenAIRE

    Siekierka Anna; Bryjak Marek

    2017-01-01

    Lithium is considered to be a critical material for various industrial fields. We present our studies on extraction lithium from diluted aqueous solution by novel hybrid system based on a membrane capacitive deionization and batteries desalination. Hybrid CDI is comprised by a lithium selective adsorbent, activated carbon electrode and anion-exchange membranes. Here, we demonstrated implication of various type of anion-exchange membranes and influence their properties on effective capacity an...

  2. Sorption of vanillin on highly basic anion exchanger under static conditions

    Science.gov (United States)

    Sholokhova, A. Yu.; Eliseeva, T. V.; Voronyuk, I. V.

    2017-11-01

    The kinetics of the sorption of vanillin by a granulated anion exchanger is studied under static conditions. A comparison of the kinetic curves of the uptake of hydroxybenzaldehyde by gel and macroporous anion exchanger shows that macroporous sorbent has better kinetic characteristics. The effect temperature has on the capacity of an anion exchanger and the time needed to establish sorption equilibrium is found, and the activation energy of vanillin uptake is determined. Studying the effect experimental factors have on the rate of sorption and using the formal kinetics approach, it is established that in the investigated range of concentrations, the limiting stage of the uptake of vanillin by an anion exchanger with the functional groups of a quaternary ammonium base is that of external diffusion. Vanillin sorption by a highly basic anion exchanger in hydroxyl form is characterized by polymolecular uptake best described by a BET isotherm; at the same time, the uptake of sorbate by a chloride form is of a monomolecular character and can be described by a Freindlich isotherm. Structural changes in the anion exchanger sorbed hydroxybenzaldehyde are identified via FTIR spectroscopy.

  3. Anion exchanger and the resistance against thermal haemolysis.

    Science.gov (United States)

    Ivanov, I T; Zheleva, A; Zlatanov, I

    2011-01-01

    4,4'-Diiso-thiocyanato stilbene-2,2'-disulphonic acid (DIDS) is a membrane-impermeable, highly specific covalent inhibitor and powerful thermal stabiliser of the anion exchanger (AE1), the major integral protein of erythrocyte membrane (EM). Suspensions of control and DIDS-treated (15 µM, pH 8.2) human erythrocytes were heated from 20° to 70°C using various but constant heating rates (1-8°C/min). The cellular electrolyte leakage exhibited a sigmoidal response to temperature as detected by conductometry. The critical midpoint temperature of leakage, T(mo), extrapolated to low heating rate (0.5°C/min) was used as a measure for EM thermostability. T(mo) was greater for DIDS-treated erythrocytes, 63.2° ± 0.3°C, than for intact erythrocytes, 60.7° ± 0.2°C. The time, t(1/2), for 50% haemolysis of erythrocytes, exposed to 53°C was used as a measure for the resistance of erythrocytes against thermal haemolysis. The t(1/2) was also greater for DIDS-treated erythrocytes, 63 ± 3 min, than for intact erythrocytes, 38 ± 2 min. The fluorescent label N-(3-pyrenyl)maleimide and EPR spin label 3-maleimido-proxyl, covalently bound to sulphydryl groups of major EM proteins, were used to monitor the changes in molecular motions during transient heating. Both labels reported an intensification of the motional dynamics at the denaturation temperatures of spectrin (50°C) and AE1 (67°C), and, surprisingly, immobilisation of a major EM protein, presumably the AE1, at T(mo). The above results are interpreted in favour of the possible involvement of a predenaturational rearrangement of AE1 copies in the EM thermostability and the resistance against thermal haemolysis.

  4. A weak-base fibrous anion exchanger effective for rapid phosphate removal from water.

    Science.gov (United States)

    Awual, Md Rabiul; Jyo, Akinori; El-Safty, Sherif A; Tamada, Masao; Seko, Noriaki

    2011-04-15

    This work investigated that weak-base anion exchange fibers named FVA-c and FVA-f were selectively and rapidly taken up phosphate from water. The chemical structure of both FVA-c and FVA-f was the same; i.e., poly(vinylamine) chains grafted onto polyethylene coated polypropylene fibers. Batch study using FVA-c clarified that this preferred phosphate to chloride, nitrate and sulfate in neutral pH region and an equilibrium capacity of FVA-c for phosphate was from 2.45 to 6.87 mmol/g. Column study using FVA-f made it clear that breakthrough capacities of FVA-f were not strongly affected by flow rates from 150 to 2000 h(-1) as well as phosphate feed concentration from 0.072 to 1.6mM. Under these conditions, breakthrough capacities were from 0.84 to 1.43 mmol/g indicating high kinetic performances. Trace concentration of phosphate was also removed from feeds containing 0.021 and 0.035 mM of phosphate at high feed flow rate of 2500 h(-1), breakthrough capacities were 0.676 and 0.741 mmol/g, respectively. The column study also clarified that chloride and sulfate did not strongly interfere with phosphate uptake even in their presence of equimolar and fivefold molar levels. Adsorbed phosphate on FVA-f was quantitatively eluted with 1M HCl acid and regenerated into hydrochloride form simultaneously for next phosphate adsorption operation. Therefore, FVA-f is able to use long time even under rigorous chemical treatment of multiple regeneration/reuse cycles without any noticeable deterioration. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Novel tentacle-type polymer stationary phase grafted with anion exchange polymer chains for open tubular CEC of nucleosides and proteins.

    Science.gov (United States)

    Aydoğan, Cemil; Çetin, Kemal; Denizli, Adil

    2014-08-07

    A novel and simple method for preparation of a tentacle-type polymer stationary phase grafted with polyethyleneimine (PEI) anion exchanger was developed for open tubular capillary electrochromatography (OT-CEC) of nucleosides and proteins. The polymeric stationary phase was prepared using 3-chloro-2-hydroxypropyl methacrylate (HPMA-Cl)-based reactive monomer. The preparation procedure included pretreatment of the capillary inner wall, silanization, in situ graft polymerization with HPMA-Cl and PEI modification. To compare with the tentacle-type capillary column with PEI functionalization, a monolayer capillary column without PEI functionalization was also prepared. The electrochromatographic characterization of the prepared open tubular column was performed using alkylbenzenes. The electroosmotic flow (EOF) with regard to PEI concentrations and the running buffer pH was investigated. The separation conditions of the nucleosides and the proteins were optimized. The modified tentacle-type column with high anion exchange capacity has proven to afford better retention and resolution for the separation of nucleosides and proteins. The PEI functionalization column can also provide long-term stable use for biomolecule separation using a single capillary with relative standard deviation values of retention times of less than 2%. The results indicate that the present method for open tubular capillary preparation with a HPMA-Cl-based reactive monomer is promising for OT-CEC biomolecule separation.

  6. Anion-exchange separation and estimation of thorium in niobite-tantalite type minerals: a new approach

    Energy Technology Data Exchange (ETDEWEB)

    Premadas, A. (Chemical Lab., Bangalore (India). Div. of Atomic Minerals)

    1993-08-01

    A simple, rapid and quantitative anion-exchange separation of microgram to milligram quantities of thorium has been achieved from milligram quantities of niobium, tantalum, and titanium in citric acid-nitric acid medium. This method is successfully applied for the separation and estimation of thorium in niobite-tantalite type minerals. Sample (0.500 g) is fused with ca. 8 g KHSO[sub 4] and is taken in ca. 7% citric acid medium. To a suitable aliquot ca. 8 M (1 M=1 mol dm[sup -3]) nitric acid acidity is maintained in ice cold condition, and is passed through a column of Dowex-lX8 (100-200 mesh size). Thorium is eluted with ca. 6 M CHl and estimated spectrophotometrically with arsenazo III. The RSD obtained by this method is 2-3%. (author).

  7. Feasibility and kinetics study on the direct bio-regeneration of perchlorate laden anion-exchange resin.

    Science.gov (United States)

    Wang, Chao; Lippincott, Lee; Meng, Xiaoguang

    2008-11-01

    Anion exchange is one of the most promising treatment technologies for the removal of low levels of perchlorate. The spent anion-exchange resins, however, need to be disposed of or regenerated because they contain high contents of perchlorate. This study investigated the feasibility and kinetics of a direct bio-regeneration method. The method accomplished resin regeneration and biological perchlorate destruction concurrently, by directly contacting the spent resin with the perchlorate-reducing bacteria (PRB). The results indicated that the method was effective in regeneration of perchlorate and nitrate loaded resin and the resin could be repeatedly regenerated with the method. The regenerated resin was effective, stable, and durable in the filtration treatment of perchlorate in well water from the Saddle River area, NJ. Moreover, the method was also effective in regeneration of the spent A-530E resin, which had high perchlorate affinity and was yet very difficult for regeneration with the conventional brine desorption technique. Besides, the results further suggested that the perchlorate and nitrate desorption from the loaded resin coupling with their subsequent biological reduction could be the direct bio-regeneration mechanism. No biofilm was formed on the regenerated resin surface according to a scanning electron microscopy (SEM) analysis.

  8. Hybrid capacitive deionization with anion-exchange membranes for lithium extraction

    Directory of Open Access Journals (Sweden)

    Siekierka Anna

    2017-01-01

    Full Text Available Lithium is considered to be a critical material for various industrial fields. We present our studies on extraction lithium from diluted aqueous solution by novel hybrid system based on a membrane capacitive deionization and batteries desalination. Hybrid CDI is comprised by a lithium selective adsorbent, activated carbon electrode and anion-exchange membranes. Here, we demonstrated implication of various type of anion-exchange membranes and influence their properties on effective capacity and energy requirements in charge/discharge steps. We described a configuration with anion-exchange membrane characterized by adsorption capacity of 35 mg/g of Li+ with 0.08Wh/g and removal efficiency of 60 % of lithium ions, using novel selective desalination technique.

  9. Hybrid capacitive deionization with anion-exchange membranes for lithium extraction

    Science.gov (United States)

    Siekierka, Anna; Bryjak, Marek

    2017-11-01

    Lithium is considered to be a critical material for various industrial fields. We present our studies on extraction lithium from diluted aqueous solution by novel hybrid system based on a membrane capacitive deionization and batteries desalination. Hybrid CDI is comprised by a lithium selective adsorbent, activated carbon electrode and anion-exchange membranes. Here, we demonstrated implication of various type of anion-exchange membranes and influence their properties on effective capacity and energy requirements in charge/discharge steps. We described a configuration with anion-exchange membrane characterized by adsorption capacity of 35 mg/g of Li+ with 0.08Wh/g and removal efficiency of 60 % of lithium ions, using novel selective desalination technique.

  10. Separation of metal ions by anion exchange in mixtures of hydrochloric acid and hydrofluoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Faris, J.P.

    1978-12-01

    Distribution coefficients were determined for the adsorption of more than 40 elements on anion-exchange resins from mixtures of HCl (0.1 to 12M) and HF (0.1-8M). Two resins, Dowex 1 x 10, 200 to 400 mesh and Dowex 1 x 4, 100 to 200 mesh, were used. Distribution coefficients were also determined for the adsorption of many elements on both resins from 0.1 to 12M HCl and 0.1 to 12M HF. Anion exchange in the presence of HF was found useful for separating impurities from various materials for their subsequent determination, and specific procedures used in our spectrochemical laboratory for this purpose are outlined. The results of a literature search on the use of anion exchange in hydrofluoric acid and fluoride-containing media are presented in an extensive bibliography. 404 references, 9 tables.

  11. Separation of metal ions by anion exchange in mixtures of hydrochloric acid and hydrofluoric acid

    International Nuclear Information System (INIS)

    Faris, J.P.

    1978-12-01

    Distribution coefficients were determined for the adsorption of more than 40 elements on anion-exchange resins from mixtures of HCl (0.1 to 12M) and HF (0.1-8M). Two resins, Dowex 1 x 10, 200 to 400 mesh and Dowex 1 x 4, 100 to 200 mesh, were used. Distribution coefficients were also determined for the adsorption of many elements on both resins from 0.1 to 12M HCl and 0.1 to 12M HF. Anion exchange in the presence of HF was found useful for separating impurities from various materials for their subsequent determination, and specific procedures used in our spectrochemical laboratory for this purpose are outlined. The results of a literature search on the use of anion exchange in hydrofluoric acid and fluoride-containing media are presented in an extensive bibliography. 404 references, 9 tables

  12. Quaternized poly (styrene-co-vinylbenzyl chloride) anion exchange membranes for alkaline water electrolysers

    Science.gov (United States)

    Vengatesan, S.; Santhi, S.; Jeevanantham, S.; Sozhan, G.

    2015-06-01

    In this study, poly (ST-co-VBC) based anion exchange membranes with different styrene to VBC ratios (1: 0.16, 1: 0.33 and 1: 1) have been prepared via chloromethylation-free synthetic route using aromatic vinyl monomers. The synthesized co-polymers are identified by FTIR and 1H-NMR analysis. Hydroxide (OH-) ion conductivity of the anion exchange membrane with styrene to VBC ratio of 1: 0.33 is as high as 6.8 × 10-3 S cm-1 in de-ionised water at 25 °C. The membrane also acquires the ion-exchange capacity of 2.14 meq. g-1, and the water uptake of 127%. Membrane-electrode-assembly (MEA) using the anion exchange membrane and Ni - foam catalyst demonstrate the current density of 40 mA cm-2 at 2.3 V in a water electrolyser cell.

  13. Recovery of 238Pu from irradiated 237Np using anion exchange method

    International Nuclear Information System (INIS)

    Zhang Shaoqi; Hu Huaizhong; Zhang Qinfen; Xue Shijin; Tang Xuzhen; Qin Zhongxian; Zhu Shuzhong

    1986-04-01

    A process for recovering and purifying 238 Pu from irradiated NpO 2 target by anion exchange method is described in detail. Related results obtained in the technological experiment for the process are given. First, absorb and desorb behaviour of 237 Np- 239 Pu on the anion exchange columu using 237 Np and 239 Pu, various factors effecting 237 Np/ 239 Pu separation were investigated, then, we selected technical parameters for the four cycles process. Finally, a 'hot' experiment was conducted using an irradiated NpO 2 target. The cross-contamination of 237 Np and 238 Pu is less than 1%, the total recoveries of 237 Np and 238 Pu are respectively 99.6% and 98.1%. The total γ elimination coefficient of 237 Np- 238 Pu obtained in the first anion exchange cycle is 2.4 x 10 3

  14. Facile preparation of salt-tolerant anion-exchange membrane adsorber using hydrophobic membrane as substrate.

    Science.gov (United States)

    Fan, Jinxin; Luo, Jianquan; Chen, Xiangrong; Wan, Yinhua

    2017-03-24

    In this study, a polyvinylidene fluoride (PVDF) hydrophobic membrane with high mechanical property was used as substrate to prepare salt-tolerant anion-exchange (STAE) membrane adsorber. Effective hydrophilization and functionalization of PVDF membrane was realized via polydopamine (PDA) deposition, thus overcoming the drawbacks of hydrophobic substrates including poor water permeability, inert property as well as severe non-specific adsorption. The following polyallylamine (PAH) coupling was carried out at pH 10.0, where unprotonated amine groups on PAH chains were more prone to couple with PDA. This membrane adsorber could remain 75% of protein binding capacity when NaCl concentration increased from 0 to 150mM, while its protein binding capacity was independent of flow rate from 10 to 100 membrane volume (MV)/min due to its high mechanical strength (tensile strength: 43.58±2.30MPa). With 200mM NaCl addition at pH 7.5, high purity (above 99%) and high recovery (almost 100%) of Immunoglobulin G (IgG) were obtained when using the STAE membrane adsorber to separate IgG/human serum albumin (HSA) mixture, being similar to that without NaCl at pH 6.0 (both under the flow rate of 10-100MV/min). Finally, the reliable reusability was confirmed by five reuse cycles of protein binding and elution operations. In comparison with commercial membrane adsorber, the new membrane adsorber exhibited a better mechanical property, higher IgG polishing efficiency and reusability, while the protein binding capacity was lower due to less NH 2 density on the membrane. The outcome of this work not only offers a facile and effective approach to prepare membrane adsorbers based on hydrophobic membranes, but also demonstrates great potential of this new designed STAE membrane adsorbers for efficient monoclonal antibody (mAb) polishing. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Radiation stability of anion-exchange resins based on epichlorohydrin and vinylpyridines

    International Nuclear Information System (INIS)

    Zainutdinov, S.S.; Dzhalilov, A.T.; Askarov, M.A.

    1983-01-01

    The vigorous development of nuclear technology and atomic energy and the hydrometallurgy of the rare and radioactive metals has made it necessary to create and use ion-exchange materials possessing a high resistance to the action of ionizing radiations and the temperature. In view of this, the necessity has arisen for obtaining ion-exchange materials possessing adequate radiation stability. The results of an investigation of the radiation stability of anion-exchange resins based on the products of spontaneous polymerization in the interaction of epichlorohydrin with vinylpyridines show that they possess higher radiation resistance than the industrial anion-exchange resin AN-31 used at the present time

  16. Rapid anion exchange separation of fermium with mineral acid-methyl alcohol mixed media

    International Nuclear Information System (INIS)

    Usuda, S.; Shinohara, N.; Ichikawa, S.; Suzuki, T.

    1987-01-01

    Anion exchange separation of 250 Fm (30 m) synthesized by the 12 C+ 242 Pu and 16 O+ 238 U reactions was investigated with mineral acid-methyl alcohol mixed media at elevated temperature. Fermium was chromatographically separated from the other transplutonium elements, the target materials and an Al catcher foil by anion exchange with mixtures of nitric acid and methyl alcohol. By use of the mixed media of hydrochloric acid and methyl alcohol, Fm together with Cf was separated from Al, Am, Cm, Pu, U and from major fission products. The separation systems are suitable for rapid separation and immediate alpha-counting source preparation of Fm. (author) 22 refs.; 4 figs

  17. Anion-exchange synthesis of nanoporous FeP nanosheets as electrocatalysts for hydrogen evolution reaction.

    Science.gov (United States)

    Xu, You; Wu, Rui; Zhang, Jingfang; Shi, Yanmei; Zhang, Bin

    2013-07-28

    Nanoporous FeP nanosheets are successfully synthesized via the anion-exchange reaction of inorganic-organic hybrid Fe18S25-TETAH (TETAH = protonated triethylenetetramine) nanosheets with P ions. The as-prepared nanoporous FeP nanosheets exhibit high electrochemical hydrogen evolution reaction activity in acidic medium.

  18. Anion-exchange membranes containing diamines: preparation and stability in alkaline solution

    NARCIS (Netherlands)

    Komkova, E.N.; Komkova, E.N.; Stamatialis, Dimitrios; Strathmann, H.; Wessling, Matthias

    2004-01-01

    Anion-exchange membranes (AEM) are prepared from chloromethylated polysulfone and a number of diamine compounds. The properties of the new AEM including the water content, ion-exchange capacity, permselectivity and area resistance are thoroughly studied. By varying the amount of diamine into the

  19. Synthesis and anion exchange reactions of a layered copper–zinc ...

    Indian Academy of Sciences (India)

    Unknown

    629. *For correspondence. Synthesis and anion exchange reactions of a layered copper–zinc hydroxy double salt, Cu1⋅6Zn0⋅4(OH)3(OAc)⋅H2O. JACQUELINE THERESE RAJAMATHI, SYLVIA BRITTO and MICHAEL RAJAMATHI*. Department of Chemistry, St. Joseph's College, Lalbagh Road, Bangalore 560 027, India.

  20. Improved recovery of trace amounts of gold (III), palladium (II) and platinum (IV) from large amounts of associated base metals using anion-exchange resins

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, I. [Lab. of Chemistry, Tokyo Women' s Medical Univ. (Japan); Takeda, Y.; Ishida, K. [Lab. of Chemistry, Nippon Medical School, Kawasaki-shi, Kanagawa-ken (Japan)

    2000-02-01

    The adsorption and desorption behaviors of gold (III), palladium (II) and platinum (IV) were surveyed in column chromatographic systems consisting of one of the conventional anion-exchange resins of large ion-exchange capacity and dilute thiourea solutions. The noble metals were strongly adsorbed on the anion-exchange resins from dilute hydrochloric acid, while most base metals did not show any marked adsorbability. These facts made it possible to separate the noble metals from a large quantity of base metals such as Ag (I), Al (III), Co (II), Cu (II), Fe (III), Mn (II), Ni (II), Pb (II), and Zn (II). Although it used to be very difficult to desorb the noble metals from the resins used, the difficulty was easily overcome by use of dilute thiourea solutions as an eluant. In the present study, as little as 1.00 {mu}g of the respective noble metals was quantitatively separated and recovered from as much as ca. 10 mg of a number of metals on a small column by elution with a small amount of dilute thiourea solution. The present systems should be applicable to the separation, concentration and recovery of traces of the noble metals from a number of base metals coexisting in a more extended range of amounts and ratios. (orig.)

  1. Removal of Congo Red from Aqueous Solution by Anion Exchange Membrane (EBTAC): Adsorption Kinetics and Themodynamics

    Science.gov (United States)

    Khan, Muhammad Imran; Akhtar, Shahbaz; Zafar, Shagufta; Shaheen, Aqeela; Khan, Muhammad Ali; Luque, Rafael; ur Rehman, Aziz

    2015-01-01

    The adsorption behavior of anionic dye congo red (CR) from aqueous solutions using an anion exchange membrane (EBTAC) has been investigated at room temperature. The effect of several factors including contact time, membrane dosage, ionic strength and temperature were studied. Kinetic models, namely pseudo-first-order and pseudo-second-order, liquid film diffusion and Elovich models as well as Bangham and modified freundlich Equations, were employed to evaluate the experimental results. Parameters such as adsorption capacities, rate constant and related correlation coefficients for every model were calculated and discussed. The adsorption of CR on anion exchange membranes followed pseudo-second-order Kinetics. Thermodynamic parameters, namely changes in Gibbs free energy (∆G°), enthalpy (∆H°) and entropy (∆S°) were calculated for the adsorption of congo red, indicating an exothermic process. PMID:28793430

  2. Removal of Congo Red from Aqueous Solution by Anion Exchange Membrane (EBTAC): Adsorption Kinetics and Themodynamics.

    Science.gov (United States)

    Khan, Muhammad Imran; Akhtar, Shahbaz; Zafar, Shagufta; Shaheen, Aqeela; Khan, Muhammad Ali; Luque, Rafael; Rehman, Aziz Ur

    2015-07-08

    The adsorption behavior of anionic dye congo red (CR) from aqueous solutions using an anion exchange membrane (EBTAC) has been investigated at room temperature. The effect of several factors including contact time, membrane dosage, ionic strength and temperature were studied. Kinetic models, namely pseudo-first-order and pseudo-second-order, liquid film diffusion and Elovich models as well as Bangham and modified freundlich Equations, were employed to evaluate the experimental results. Parameters such as adsorption capacities, rate constant and related correlation coefficients for every model were calculated and discussed. The adsorption of CR on anion exchange membranes followed pseudo-second-order Kinetics. Thermodynamic parameters, namely changes in Gibbs free energy ( ∆G° ), enthalpy ( ∆H° ) and entropy ( ∆S° ) were calculated for the adsorption of congo red, indicating an exothermic process.

  3. Use of Anion Exchange Resins for One-Step Processing of Algae from Harvest to Biofuel

    OpenAIRE

    Jessica Jones; Cheng-Han Lee; James Wang; Martin Poenie

    2012-01-01

    Some microalgae are particularly attractive as a renewable feedstock for biodiesel production due to their rapid growth, high content of triacylglycerols, and ability to be grown on non-arable land. Unfortunately, obtaining oil from algae is currently cost prohibitive in part due to the need to pump and process large volumes of dilute algal suspensions. In an effort to circumvent this problem, we have explored the use of anion exchange resins for simplifying the processing of algae to biofuel...

  4. Cross-linked comb-shaped anion exchange membranes with high base stability

    Energy Technology Data Exchange (ETDEWEB)

    Li, NW; Wang, LZ; Hickner, M

    2014-01-01

    A unique one-step cross-linking strategy that connects quaternary ammonium centers using Grubbs II-catalyzed olefin metathesis was developed. The cross-linked anion exchange membranes showed swelling ratios of less than 10% and hydroxide conductivities of 18 to 40 mS cm(- 1). Cross-linking improved the membranes' stability to hydroxide degradation compared to their non-cross-linked analogues.

  5. Preparation of nuclear grade strongly basic anion exchange resin in hydroxide from

    International Nuclear Information System (INIS)

    Ke Weiqing

    1989-01-01

    The two-step transformation method was used to prepare 90 kg nuclear grade strongly basic anion exchange resins by using the industrial grade baking soda and caustic soda manufacutred by mercury-cathode electrolysis. The chloride and biscarbonate fraction on resin is 0.8% and 1.25% respectively, when the baking soda and caustic soda consumption is 8.6 and 13.7 times the total exchange capacity of the strongly basic resin

  6. Absence of transepithelial anion exchange by rabbit OMCD: Evidence against reversal of cell polarity

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Matsuhiko; Schuster, V.L.; Stokes, J.B. (Univ. of Iowa College of Medicine, Iowa City (USA))

    1988-08-01

    In the rabbit cortical collecting duct (CCD), Cl tracer crosses the epithelium predominantly via an anion exchange system that operates in either a Cl-Cl or Cl-HCO{sub 3} exchange mode. In the present study, the authors used the {sup 36}Cl lumen-to-bath rate coefficient (K{sub Cl}, nm/s), a sensitive measurement of CCD transepithelial anion transport, to investigate the nature of Cl transport in the medullary collecting duct dissected from inner stripe, outer medulla (OMCD). The K{sub Cl} in OMCD perfused and bathed in HCO{sub 3}-Ringer solution was low and similar to that value observed in the CCD when anion exchange is inhibited and Cl permeates the epithelium by diffusion. To test the hypothesis that metabolic alkalosis could reverse the polarity of intercalated cells and thus induce an apical Cl-HCO{sub 3} exchanger in H{sup +}-secreting OMCD cells, they measured K{sub Cl} in OMCD from rabbits make alkalotic by deoxycorticosterone and furosemide. Although the base-line K{sub Cl} was slightly higher than in OMCD from control rabbits, the value was still far lower than the K{sub Cl} under comparable conditions in CCD. They conclude (1) Cl transport across the MCD by anion exchange is immeasurably low or nonexistent; (2) unlike the CCD, Cl transport in OMCD is not responsive to cAMP; and (3) metabolic alkalosis does not induce an apical anion exchanger in OMCD, i.e., does not cause epithelial polarity reversal.

  7. Test procedure for anion exchange testing with Argonne 10-L solutions

    International Nuclear Information System (INIS)

    Compton, J.A.

    1995-01-01

    Four anion exchange resins will be tested to confirm that they will sorb and release plutonium from/to the appropriate solutions in the presence of other cations. Certain cations need to be removed from the test solutions to minimize adverse behavior in other processing equipment. The ion exchange resins will be tested using old laboratory solutions from Argonne National Laboratory; results will be compared to results from other similar processes for application to all plutonium solutions stored in the Plutonium Finishing Plant

  8. Importance of balancing membrane and electrode water in anion exchange membrane fuel cells

    Science.gov (United States)

    Omasta, T. J.; Wang, L.; Peng, X.; Lewis, C. A.; Varcoe, J. R.; Mustain, W. E.

    2018-01-01

    Anion exchange membrane fuel cells (AEMFCs) offer several potential advantages over proton exchange membrane fuel cells (PEMFCs), most notably to overcome the cost barrier that has slowed the growth and large scale implementation of fuel cells for transportation. However, limitations in performance have held back AEMFCs, specifically in the areas of stability, carbonation, and maximum achievable current and power densities. In order for AEMFCs to contend with PEMFCs for market viability, it is necessary to realize a competitive cell performance. This work demonstrates a new benchmark for a H2/O2 AEMFC with a peak power density of 1.4 W cm-2 at 60 °C. This was accomplished by taking a more precise look at balancing necessary membrane hydration while preventing electrode flooding, which somewhat surprisingly can occur both at the anode and the cathode. Specifically, radiation-grafted ETFE-based anion exchange membranes and anion exchange ionomer powder, functionalized with benchmark benzyltrimethylammonium groups, were utilized to examine the effects of the following parameters on AEMFC performance: feed gas flow rate, the use of hydrophobic vs. hydrophilic gas diffusion layers, and gas feed dew points.

  9. Alkaline anion exchange membrane fuel cells for cogeneration of electricity and valuable chemicals

    Science.gov (United States)

    Pan, Z. F.; Chen, R.; An, L.; Li, Y. S.

    2017-10-01

    Alkaline anion exchange membrane fuel cells (AAEMFCs) have received ever-increasing attentions due to the enhanced electrochemical kinetics and the absence of precious metal electrocatalysts, and thus great progress has been made in recent years. The alkaline anion exchange membrane based direct alcohol fuel cells, one type of alkaline anion exchange membrane fuel cells utilizing liquid alcohols as fuel that can be obtained from renewable biomass feedstocks, is another attractive point due to its ability to provide electricity with cogeneration of valuable chemicals. Significant development has been made to improve the selectivity towards high added-value chemicals and power output in the past few years. This review article provides a general description of this emerging technology, including fuel-cell setup and potential reaction routes, summarizes the products, performance, and system designs, as well as introduces the application of this concept in the removal of heavy-metal ions from the industrial wastewater. In addition, the remaining challenges and perspectives are also highlighted.

  10. Fabrication of a micrometer Ni–Cu alloy column coupled with a Cu micro-column for thermal measurement

    International Nuclear Information System (INIS)

    Lin, J C; Chang, T K; Yang, J H; Jeng, J H; Lee, D L; Jiang, S B

    2009-01-01

    Micrometer Ni–Cu alloy columns have been fabricated by the micro-anode-guided electroplating (MAGE) process in the citrate bath. The surface morphology and chemical composition of the micro-columns were determined by copper concentration in the bath and by the electrical bias of MAGE. When fabricated in a bath of dilute copper (i.e. 4 mM) at lower voltages (e.g. 3.8 and 4.0 V), the alloy micro-columns revealed uniform diameter and smooth appearance. The alloy composition demonstrated an increase in the wt% ratio of Ni/Cu from 75/25, 80/20, 83/17 to 87/13 with increasing electrical bias from 3.8, 4.0, 4.2 to 4.4 V. However, it decreases from 75/25, 57/43 to 47/53 with increasing copper concentration from 4, 8 to 12 mM in the bath. Citrate plays a role in forming complexes with nickel and copper at similar reduction potentials, thus reducing simultaneously to Ni–Cu alloy. The mechanism for fabricating alloy micro-columns could be delineated on the basis of cathodic polarization of the complexes. A couple of micro-columns were fabricated using MAGE in constructing a pure copper micro-column on the top of a Ni/Cu (at 47/53) alloy micro-column. This micro-thermocouple provides a satisfactory measurement with good sensitivity and precision

  11. The effect of protein A cycle number on the performance and lifetime of an anion exchange polishing step.

    Science.gov (United States)

    Iskra, Timothy; Bolton, Glen R; Coffman, Jonathan L; Godavarti, Ranga

    2013-04-01

    Most mAb platform purification processes consist of an affinity capture step followed by one or two polishing steps. An understanding of the performance linkages between the unit operations can lead to robust manufacturing processes. In this study, a weak-partitioning anion-exchange chromatography polishing step used in a mAb purification process was characterized through high-throughput screening (HTS) experiments, small-scale experiments including a cycling study performed on qualified scale-down models, and large-scale manufacturing runs. When material from a Protein A column that had been cycled Protein A resin increased, the capacity of the subsequent AEX step increased. Different control strategies were considered for preventing impurity breakthrough and improving AEX resin lifetimes. Depth filtration of the Protein A peak pool significantly improved the AEX resin capacity, robustness, and lifetime. Further, the turbidity of the Protein A pool has the potential for use as an in-process control parameter for monitoring the performance of the AEX step. Copyright © 2012 Wiley Periodicals, Inc.

  12. Determination of sugar compounds in olive plant extracts by anion-exchange chromatography with pulsed amperometric detection.

    Science.gov (United States)

    Cataldi, T R; Margiotta, G; Iasi, L; Di Chio, B; Xiloyannis, C; Bufo, S A

    2000-08-15

    We describe a chromatographic method that uses isocratic elution and pulsed amperometric detection to determine soluble carbohydrates in plant tissues. Such a method provides a rapid and convenient means to obtain a complete profile of the sugar components of leaves and roots from olive (Olea europaea L. cv. Coratina) plants. A simple purification of plant extracts using pure water was developed, which is far less time-consuming and retains a high level of accuracy. Excellent separation of myo-inositol, galactinol, mannitol, galactose, glucose, fructose, sucrose, raffinose, and stachyose was achieved with an anion-exchange column and 12 mM NaOH spiked with 1 mM barium acetate as an eluent. At a flow rate of 1.0 mL/min, the time of analysis was less than 25 min, and repeatability of the method on the order of 2.2% as RSD or better for retention times and lower than 5.2% for peak areas. Recoveries approximated 100% (range 97.2-104.5%), and the method provided good precision with a coefficient of variation which ranged between 0.9 and 3.3%. Among identified carbohydrates extracted from leaves and roots of olive plants, glucose and mannitol were major compounds. Their molar ratio was estimated to be 1.2+/-0.1 and 2.2+/-0.3 for olive leaves and roots, respectively. The occurrence of soluble galactinol in plant tissues was also validated.

  13. Studies on the absorption of uranium and plutonium on macroporous anion-exchange resins from mixed solvent media

    International Nuclear Information System (INIS)

    Chetty, K.V.; Mapara, P.M.; Godbole, A.G.; Swarup, Rajendra

    1995-01-01

    The ion-exchange studies on uranium and plutonium using macroporous anion-exchange resins from an aqueous-organic solvent mixed media were carried out to develop a method for their separation. Out of the several water miscible organic solvents tried, methanol and acetone were found to be best suited. Distribution data for U(VI) and Pu(IV) for three macroporous resins Tulsion A-27(MP) (strong base), Amberlyst A-26(MP) (strong base) and Amberlite XE-270(MP) (weak base) as a function of (i) nitric acid concentration (ii) organic solvent concentration were obtained. Based on the data separation factors for Pu/U were calculated. Column experiments using Tulsion A-27(MP) from a synthetic feed (HNO 3 - methanol and HNO 3 - acetone) containing Pu and U in different ratios were carried out. Plutonium was recovered from the bulk of the actual solution generated during the dissolution of plutonium bearing fuels. The method has the advantage of loading plutonium from as low as 1M nitric acid in presence of methanol or acetone and could be used satisfactorily for its recovery from solutions containing plutonium and uranium. (author). 11 refs., 4 figs., 16 tabs

  14. A simple and rapid method for isotopic analysis of nickel, copper, and zinc in seawater using chelating extraction and anion exchange.

    Science.gov (United States)

    Takano, Shotaro; Tanimizu, Masaharu; Hirata, Takafumi; Shin, Ki-Cheol; Fukami, Yusuke; Suzuki, Katsuhiko; Sohrin, Yoshiki

    2017-05-15

    Stable isotope ratios of nickel, copper, and zinc are powerful tools for elucidating the biogeochemical cycling of trace metals in the ocean. However, analytical difficulties have impeded isotopic studies of these metals. We present a simple and rapid method for simultaneous analysis of Ni, Cu, and Zn isotope ratios in seawater using NOBIAS Chelate-PA1 resin and anion exchange resin. A NOBIAS Chelate-PA1 resin column was used to quantitatively collect Ni, Cu, and Zn from seawater and thoroughly remove the seawater matrix. Subsequent anion exchange purified and separated the Ni, Cu, and Zn from each other. The blanks used in this method (0.22 ng for Ni, 0.29 ng for Cu, and 0.53 ng for Zn) were sufficiently low to determine the isotope ratios of Ni, Cu, and Zn in surface seawater. Using this method, we analyzed GEOTRACES reference seawater samples (i.e., SAFe D1 and SAFe D2), National Research Council Canada certified materials (i.e., CASS-5 and NASS-6), and seawater samples collected from different depths in the subarctic South Pacific. The results were consistent with previously reported values. This method is expected to accelerate isotopic research and contribute to our understanding of biogeochemical cycling in the ocean. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Hydration and sorption characteristics of a polyfunctional weak-base anion exchanger after the sorption of vanillin and ethylvanillin

    Science.gov (United States)

    Rodionova, D. O.; Voronyuk, I. V.; Eliseeva, T. V.

    2016-07-01

    Features of the sorption of substituted aromatic aldehydes by a weak-base anion exchanger under equilibrium conditions are investigated using vanillin and ethylvanillin as examples. Analysis of the sorption isotherms of carbonyl compounds at different temperatures allows us to calculate the equilibrium characteristics of their sorption and assess the entropy and enthalpy contributions to the energy of the process. Hydration characteristics of the macroporous weak-base anion exchanger before and after the sorption of aromatic aldehydes are compared.

  16. Removal of fluorescent dissolved organic matter in biologically treated textile effluents by NDMP anion exchange process: efficiency and mechanism.

    Science.gov (United States)

    Li, Wen-Tao; Xu, Zi-Xiao; Shuang, Chen-Dong; Zhou, Qing; Li, Hai-Bo; Li, Ai-Min

    2016-03-01

    The efficiency and mechanism of anion exchange resin Nanda Magnetic Polymer (NDMP) for removal of fluorescent dissolved organic matter in biologically treated textile effluents were studied. The bench-scale experiments showed that as well as activated carbon, anion exchange resin could efficiently remove both aniline-like and humic-like fluorescent components, which can be up to 40 % of dissolved organic matter. The humic-like fluorescent component HS-Em460-Ex3 was more hydrophilic than HS-Em430-Ex2 and contained fewer alkyl chains but more acid groups. As a result, HS-Em460-Ex3 was eliminated more preferentially by NDMP anion exchange. However, compared with adsorption resins, the polarity of fluorescent components had a relatively small effect on the performance of anion exchange resin. The long-term pilot-scale experiments showed that the NDMP anion exchange process could remove approximately 30 % of the chemical oxygen demand and about 90 % of color from the biologically treated textile effluents. Once the issue of waste brine from resin desorption is solved, the NDMP anion exchange process could be a promising alternative for the advanced treatment of textile effluents.

  17. New system applying image processor to automatically separate cation exchange resin and anion exchange resin for condensate demineralizer

    International Nuclear Information System (INIS)

    Adachi, Tsuneyasu; Nagao, Nobuaki; Yoshimori, Yasuhide; Inoue, Takashi; Yoda, Shuji

    2014-01-01

    In PWR plant, condensate demineralizer is equipped to remove corrosive ion in condensate water. Mixed bed packing cation exchange resin (CER) and anion exchange resin (AER) is generally applied, and these are regenerated after separation to each layer periodically. Since the AER particle is slightly lighter than the CER particle, the AER layer is brought up onto the CER layer by feeding water upward from the bottom of column (backwashing). The separation performance is affected by flow rate and temperature of water for backwashing, so normally operators set the proper condition parameters regarding separation manually every time for regeneration. The authors have developed the new separation system applying CCD camera and image processor. The system is comprised of CCD camera, LED lamp, image processor, controller, flow control valves and background color panel. Blue color of the panel, which is corresponding to the complementary color against both ivory color of AER and brown color of CER, is key to secure the system precision. At first the color image of the CER via the CCD camera is digitized and memorized by the image processor. The color of CER in the field of vision of the camera is scanned by the image processor, and the position where the maximum difference of digitized color index is indicated is judged as the interface. The detected interface is able to make the accordance with the set point by adjusting the flow rate of backwashing. By adopting the blue background panel, it is also possible to draw the AER out of the column since detecting the interface of the CER clearly. The system has provided the reduction of instability factor concerning separation of resin during regeneration process. The system has been adopted in two PWR plants in Japan, it has been demonstrating its stable and precise performance. (author)

  18. New anion-exchange resins for improved separations of nuclear materials

    International Nuclear Information System (INIS)

    Barr, M.E.; Bartsch, R.A.

    1998-01-01

    'The overall objective of this research is to develop a predictive capability which allows the facile design and implementation of multi-functionalized anion-exchange materials which selectively sorb metal complexes of interest from targeted process, waste, and environmental streams. The basic scientific issues addressed are actinide complex speciation along with modeling of the metal complex/functional-site interactions in order to determine optimal binding-site characteristics. The new ion-exchange resins interface the rapidly developing field of ion-specific chelating ligands with robust, commercial ion-exchange technology. Various Focus Areas and Crosscutting Programs have described needs that would be favorably impacted by the new materials: Efficient Separations and Processing; Plutonium; Plumes; Mixed Waste; High-Level Tank Waste. Sites within the DOE complex which would benefit from the improved anion-exchange technology include Hanford, INEL, Los Alamos, Oak Ridge, and Savannah River. As of April 1998, this report summarizes work after 1.6 years of a 3-year project. The authors technical approach combines empirical testing with theoretical modeling (applied in an iterative mode) in order to determine optimal binding-site characteristics. They determine actinide-complex speciation in specific media, then develop models for the metal complex/functional-site interactions Synthesis and evaluation of multi-functionalized extractants and ion-exchange materials that implement key features of the optimized binding site provide feedback to the modeling and design activities. Resin materials which actively facilitate the uptake of actinide complexes from solution should display both improved selectivity and kinetic properties. The implementation of the bifunctionality concept involves N-derivatization of pyridinium units from a base poly(4-vinylpyridine) resin with a second cationic site such that the two anion-exchange sites are linked by spacer arms of varying

  19. Anion-exchange enrichment and spectrophotometric determination of uranium in sea-water

    International Nuclear Information System (INIS)

    Kuroda, Rokuro; Oguma, Koichi; Mukai, Noriko; Iwamoto, Masatoshi

    1987-01-01

    A method is proposed for the determination of uranium in sea-water. The uranium is strongly sorbed on a strongly basic anion-exchange resin (Cl - form) from acidified sea-water containing sodium azide (0.3M) and is easily eluted with 1M hydrochloric acid. Uranium in the effluent can be determined spectrophotometrically with Arsenazo III. The combined method allows easy and selective determination of uranium in sea-water without using a sophisticated adsorbent. The overall recovery and precision are satisfactory at the 3 μg/1. level. (author)

  20. Industrial tests and application of porous AN-21 anion exchanger for rhenium extraction

    International Nuclear Information System (INIS)

    Lebedev, K.B.; Mekler, L.I.; Kryukova, Eh.I.; Pinegina, N.D.; Sandler, E.K.

    1976-01-01

    Replacing a gel-type anion-exchange resin AN-21S6g with a highly porous resin AN-21x16p during the 2nd stage of Re extention from a soda desorbate doubled the approximate capacity, decreased the recirculating solution volume, improved Re recovery, and increased the sorbent capacity until the breakthrough. Using the porous sorbent gave complete Re extention in 1 cycle, decreased the eluant and NH 4 OH consumption and the rich eluate volume, doubled the Re concentration in eluates while decreasing the eluate evaporation, and shortened the process time

  1. Design of expanded bed supports for the recovery of plasmid DNA by anion exchange adsorption

    DEFF Research Database (Denmark)

    Theodossiou, Irini; Søndergaard, M.; Thomas, Owen R. T.

    2001-01-01

    and blueprints for improved expanded bed adsorbents have been put forward. The characterisation and testing of small (20-40 mum) high density (>3.7 g cm(-3)) pellicular expanded bed materials functionalised with various anion exchange structures is presented. In studies with calf thymus DNA, dynamic binding......In this study we detail the rational design of new chromatographic adsorbents tailored for the capture of plasmid DNA. Features present on current chromatographic supports that can significantly enhance plasmid binding capacity have been identified in packed bed chromatography experiments...... sensitivity to inter-particle bridging by nucleic acid polymers, gave low DNA recoveries (0.8 mg ml(-1)) capture of plasmid...

  2. The mechanism in the poisoning of anion-exchange resins by cobalt cyanide

    International Nuclear Information System (INIS)

    Fleming, C.A.; Hancock, R.D.

    1979-01-01

    The complex responsible for the poisoning of anion-exchange resins is identified as the anionic cobaltic pentacyanide mono aquo species. It is shown that, at high concentration, this species polymerizes in solutions of pH less than 9. A mechanism for poisoning is presented that involves adsorption of anionic cobalt cyanide by a normal ion-exchange process, followed by polymerization within the resin matrix to form complexes that are too large to diffuse readily through the resin pores. The effects of resin structure and functionality on the extent of cobalt poisoning are examined, and the effect of cobalt poisoning on the kinetics and equilibrium loading of uranium is discussed [af

  3. Synergistic desorption of molybdenum from the strong base anion exchange resin by molybdnum fouling

    International Nuclear Information System (INIS)

    Zhang Guowei; Zhao Guirong

    1988-01-01

    In this paper the synerglstic desorption of molybdenum from the strong base anion exchange resin is studied using ammonium hydroxide and ammonium sulfate, sodium hydroxide and sodium sulfate or sodium hydroxide and sodium chloride mixed chloride mixed desorbents. The coefficients of synergistlc desorption for various mixed desorbents are obtained. The experimental results show that the desorption efficiency of the mixed desorbent containing ammonium hydroxide and ammonium sulfate is so high that it can substitute for the mixed desorbent used in the plant. The harmful affect of the chloride ion on production can be eliminated if this mixed desorbent is used for the plant

  4. A basic study for the boron thermal regeneration system using anion exchange resins

    International Nuclear Information System (INIS)

    Frantiesek, P.; Kotaka, Masahiro; Okamoto, Makoto; Kakihana, Hidetake.

    1979-01-01

    For the boron thermal regeneration system (BTRS), the basic characteristics of commercial anion exchange resin have been investigated on the swelling characteristics, absorption, desorption and temperature coefficient of exchange capacity for boric acid. The equilibrium capacity increases as decrease of temperature and depends strongly on the degrees of cross linking having a maximum point at about 7% of DVB. The temperature coefficient of equilibrium capacity of boric acid is also a function of the concentration of external solution and of the cross linking having a maximum point around 7% of DVB. (author)

  5. Enhancing recovery of recombinant hepatitis B surface antigen in lab-scale and large-scale anion-exchange chromatography by optimizing the conductivity of buffers.

    Science.gov (United States)

    Mojarrad Moghanloo, Gol Mohammad; Khatami, Maryam; Javidanbardan, Amin; Hosseini, Seyed Nezamedin

    2018-01-01

    In biopharmaceutical science, ion-exchange chromatography (IEC) is a well-known purification technique to separate the impurities such as host cell proteins from recombinant proteins. However, IEC is one of the limiting steps in the purification process of recombinant hepatitis B surface antigen (rHBsAg), due to its low recovery rate (rate of 82% in both lab-scale and large-scale weak anion-exchange chromatography without any harsh effect on the purity percentage of rHBsAg. The recovery enhancement via increasing the conductivity of Eq. and Wash. buffers can be explained by their roles in reducing the binding strength and aggregation of retained particles in the column. Moreover, further increase in the salt concentration of Elut. Buffer could substantially promote the ion exchange process and the elution of retained rHBsAg. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Chitosan Derivatives as Important Biorefinery Intermediates. Quaternary Tetraalkylammonium Chitosan Derivatives Utilized in Anion Exchange Chromatography for Perchlorate Removal

    Directory of Open Access Journals (Sweden)

    Shakeela Sayed

    2015-04-01

    Full Text Available There has recently been great interest in the valorization of biomass waste in the context of the biorefinery. The biopolymer chitosan, derived from chitin, is present in large quantities of crustacean waste. This biomass can be converted into value-added products with applications in energy, fuel, chemicals and materials manufacturing. The many reported applications of this polymer can be attributed to its unique properties, such as biocompatibility, chemical versatility, biodegradability and low toxicity. Cost effective water filters which decontaminate water by removal of specific impurities and microbes are in great demand. To address this need, the development of ion exchange resins using environmentally friendly, renewable materials such as biopolymers as solid supports was evaluated. The identification and remediation of perchlorate contaminated water using an easy, inexpensive method has come under the spotlight recently. Similarly, the use of a low cost perchlorate selective solid phase extraction (SPE cartridge that can be rapidly employed in the field is desirable. Chitosan based SPE coupled with colorimetric analytical methods showed promise as a renewable anion exchange support for perchlorate analysis or removal. The polymers displayed perchlorate retention comparable to the commercial standard whereby the quaternized iron loaded polymer TMC-Fe(III displayed the best activity.

  7. Chitosan derivatives as important biorefinery intermediates. Quaternary tetraalkylammonium chitosan derivatives utilized in anion exchange chromatography for perchlorate removal.

    Science.gov (United States)

    Sayed, Shakeela; Jardine, Anwar

    2015-04-23

    There has recently been great interest in the valorization of biomass waste in the context of the biorefinery. The biopolymer chitosan, derived from chitin, is present in large quantities of crustacean waste. This biomass can be converted into value-added products with applications in energy, fuel, chemicals and materials manufacturing. The many reported applications of this polymer can be attributed to its unique properties, such as biocompatibility, chemical versatility, biodegradability and low toxicity. Cost effective water filters which decontaminate water by removal of specific impurities and microbes are in great demand. To address this need, the development of ion exchange resins using environmentally friendly, renewable materials such as biopolymers as solid supports was evaluated. The identification and remediation of perchlorate contaminated water using an easy, inexpensive method has come under the spotlight recently. Similarly, the use of a low cost perchlorate selective solid phase extraction (SPE) cartridge that can be rapidly employed in the field is desirable. Chitosan based SPE coupled with colorimetric analytical methods showed promise as a renewable anion exchange support for perchlorate analysis or removal. The polymers displayed perchlorate retention comparable to the commercial standard whereby the quaternized iron loaded polymer TMC-Fe(III) displayed the best activity.

  8. Sulfur geochemistry of hydrothermal waters in Yellowstone National Park, Wyoming, USA. III. An anion-exchange resin technique for sampling and preservation of sulfoxyanions in natural waters

    Directory of Open Access Journals (Sweden)

    Ball James W

    2003-06-01

    Full Text Available A sampling protocol for the retention, extraction, and analysis of sulfoxyanions in hydrothermal waters has been developed in the laboratory and tested at Yellowstone National Park and Green Lake, NY. Initial laboratory testing of the anion-exchange resin Bio-Rad™ AG1-X8 indicated that the resin was well suited for the sampling, preservation, and extraction of sulfate and thiosulfate. Synthetic solutions containing sulfate and thiosulfate were passed through AG1-X8 resin columns and eluted with 1 and 3 M KCl, respectively. Recovery ranged from 89 to 100%. Comparison of results for water samples collected from five pools in Yellowstone National Park between on-site IC analysis (U.S. Geological Survey mobile lab and IC analysis of resin-stored sample at SUNY-Stony Brook indicates 96 to 100% agreement for three pools (Cinder, Cistern, and an unnamed pool near Cistern and 76 and 63% agreement for two pools (Sulfur Dust and Frying Pan. Attempts to extract polythionates from the AG1-X8 resin were made using HCl solutions, but were unsuccessful. Bio-Rad™ AG2-X8, an anion-exchange resin with weaker binding sites than the AG1-X8 resin, is better suited for polythionate extraction. Sulfate and thiosulfate extraction with this resin has been accomplished with KCl solutions of 0.1 and 0.5 M, respectively. Trithionate and tetrathionate can be extracted with 4 M KCl. Higher polythionates can be extracted with 9 M hydrochloric acid. Polythionate concentrations can then be determined directly using ion chromatographic methods, and laboratory results indicate recovery of up to 90% for synthetic polythionate solutions using AG2-X8 resin columns.

  9. Determination of "net carbohydrates" using high-performance anion exchange chromatography.

    Science.gov (United States)

    Lilla, Zach; Sullivan, Darryl; Ellefson, Wayne; Welton, Kevin; Crowley, Rick

    2005-01-01

    For labeling purposes, the carbohydrate content of foods has traditionally been determined by difference. This value includes sugars, starches, fiber, dextrins, sugar alcohols, polydextrose, and various other organic compounds. In some cases, the current method may lack sufficient specificity, precision, and accuracy. These are subsequently quantitated by high performance anion exchange chromatography with pulsed amperometric detection and expressed as total nonfiber saccharides or percent "net carbohydrates." In this research, a new method was developed to address this need. The method consists of enzyme digestions to convert starches, dextrins, sugars, and polysaccharides to their respective monosaccharide components. These are subsequently quantified by high-performance anion exchange chromatography with pulsed amperometric detector and expressed as total nonfiber saccharides or percent "net carbohydrates." Hydrolyzed end products of various novel fibers and similar carbohydrates have been evaluated to ensure that they do not register as false positives in the new test method. The data generated using the "net carbohydrate" method were, in many cases, significantly different than the values produced using the traditional methodology. The recoveries obtained in a fortified drink matrix ranged from 94.9 to 105%. The coefficient of variation was 3.3%.

  10. Use of Anion Exchange Resins for One-Step Processing of Algae from Harvest to Biofuel

    Directory of Open Access Journals (Sweden)

    Martin Poenie

    2012-07-01

    Full Text Available Some microalgae are particularly attractive as a renewable feedstock for biodiesel production due to their rapid growth, high content of triacylglycerols, and ability to be grown on non-arable land. Unfortunately, obtaining oil from algae is currently cost prohibitive in part due to the need to pump and process large volumes of dilute algal suspensions. In an effort to circumvent this problem, we have explored the use of anion exchange resins for simplifying the processing of algae to biofuel. Anion exchange resins can bind and accumulate the algal cells out of suspension to form a dewatered concentrate. Treatment of the resin-bound algae with sulfuric acid/methanol elutes the algae and regenerates the resin while converting algal lipids to biodiesel. Hydrophobic polymers can remove biodiesel from the sulfuric acid/methanol, allowing the transesterification reagent to be reused. We show that in situ transesterification of algal lipids can efficiently convert algal lipids to fatty acid methyl esters while allowing the resin and transesterification reagent to be recycled numerous times without loss of effectiveness.

  11. Russian studies of the safety of anion exchange in nitric acid

    Energy Technology Data Exchange (ETDEWEB)

    Hyder, M.L.; Bartenev, S.A.; Lazarev, L.N. [and others

    1997-07-01

    Synthetic ion exchange resins came into use in the Soviet Union in the 1950`s, and domestic anion exchange resins based on quaternary amine groups have long been used in the Russian nuclear industry. These resins are similar to resins used in the West, and include pyridine-based resins, as well as the more conventional aryl polymers with substituted methyl amines. (Slide 1) The sensitivity of these amines to reaction with nitric acid and other oxidants has been a concern in Russia as in the West, and numerous laboratory studies have been conducted on the reactions involved. Several incidents involving pressure or temperature excursions have provided incentives for such studies. (Slide 2) This report briefly summarizes this work. A report by the Russian authors of this paper providing greater detail is to be issued as a U.S. Dept. of Energy document. Additionally, a second report by these authors, describing new studies on anion exchange resin safety, will also be issued as a DOE report. The separation of plutonium, neptunium, etc. from other materials by ion exchange requires rather strong nitric acid (6-8 M). In some systems, such as the processing of {sup 238}Pu, intense ionizing radiation may also be present during ion exchange separation. As a result, it is necessary to consider not only thermal hydrolysis and oxidation and their effects on the resin, but also radiolysis. All of these were investigated in the Russian studies.

  12. Preparation and performance evaluation of novel alkaline stable anion exchange membranes

    Science.gov (United States)

    Irfan, Muhammad; Bakangura, Erigene; Afsar, Noor Ul; Hossain, Md. Masem; Ran, Jin; Xu, Tongwen

    2017-07-01

    Novel alkaline stable anion exchange membranes are prepared from various amounts of N-methyl dipicolylamine (MDPA) and brominated poly (2,6-dimethyl-1,4-phenylene oxide) (BPPO). The dipicolylamine and MDPA are synthesized through condensation reaction and confirmed by 1H NMR spectroscopy. The morphologies of prepared membranes are investigated by atomic force microscopy (AFM), fourier transform infrared spectroscopy (FTIR), 1H NMR spectroscopy and scanning electron microscopy (SEM). The electrochemical and physical properties of AEMs are tested comprising water uptake (WU), ion exchange capacity (IEC), alkaline stability, linear expansion ratio (LER), thermal stability and mechanical stability. The obtained hydroxide conductivity of MDPA-4 is 66.5 mS/cm at 80 °C. The MDPA-4 membrane shows good alkaline stability, high hydroxide conductivity, low methanol permeability (3.43 × 10-7 cm2/s), higher selectivity (8.26 × 107 mS s/cm3), less water uptake (41.1%) and lower linear expansion (11.1%) despite of high IEC value (1.62 mmol/g). The results prove that MDPA membranes have great potential application in anion exchange membrane fuel cell.

  13. Adsorption Equilibrium Equation of Carboxylic Acids on Anion-Exchange Resins in Water.

    Science.gov (United States)

    Kanazawa, Nobuhiro; Urano, Kohei; Kokado, Naohiro; Urushigawa, Yoshikuni

    2001-06-01

    The adsorption of propionic acid and benzoic acid on anion-exchange resins was analyzed, and an adsorption equilibrium equation of carboxylic acids was proposed. The adsorption of carboxylic acids on the anion-exchange resins was considered to be the sum of the physical adsorption of the molecule and the ion-exchange adsorption of the ion, which were independent of each other. For the physical adsorption of carboxylic acids, it was conformed to the Freundlich equation. For the ion-exchange adsorption of carboxylate ions, the equilibrium equation corresponded well with the experimental results for wide ranges of concentration and pH. The equation contains a selectivity coefficient S(A)(Cl) for the chloride ion versus the carboxylate ion, which was considered essentially a constant. The influent of the bicarbonate ion from carbon dioxide in air could also be expressed by the additional equilibrium equation with the selectivity coefficient S(HCO(3))(Cl) for the chloride ion versus the bicarbonate ion. Consequently, an adsorption equilibrium equation can estimate the equilibrium adsorption amounts. Even the effect of a coexisting bicarbonate ion is inconsequential when the parameters of the Freundlich isotherm equation and the selectivity coefficients of the carboxylate ion and the bicarbonate ion in each resin are determined in advance. Copyright 2001 Academic Press.

  14. Qualification of Reillex{trademark} HPQ anion exchange resin for use in SRS processes

    Energy Technology Data Exchange (ETDEWEB)

    Crooks, W.J. III

    2000-05-18

    The Phase 2 portion of the HB-Line facility was built in the early 1980's to process plutonium and neptunium from nitric acid solutions into oxide suitable for storage in a vault. Although the other portions of HB-Line were started up in the mid 1980's and have operated since that time, the anion exchange and precipitation processes in Phase 2 were never started up. As part of the material stabilization efforts, Phase 2 is currently being started up. A new anion exchange resin is needed because the resins that were proposed for use 10 years ago are limited by performance characteristics, disposal requirements, or are no longer commercially available. SRTC is responsible for qualifying all resins prior to their use in Nuclear Materials Stabilization and Storage (NMSS) processes. Qualification consists of both process suitability and thermal stability with nitric acid. This report describes the thermal stability qualification of Reillex{trademark} HPQ, the new resin proposed for processing plutonium and neptunium in the HB Line facility.

  15. Removal of tartrazine from aqueous solutions by strongly basic polystyrene anion exchange resins.

    Science.gov (United States)

    Wawrzkiewicz, Monika; Hubicki, Zbigniew

    2009-05-30

    The removal of tartrazine from aqueous solutions onto the strongly basic polystyrene anion exchangers of type 1 (Amberlite IRA-900) and type 2 (Amberlite IRA-910) was investigated. The experimental data obtained at 100, 200, 300 and 500 mg/dm(3) initial concentrations at 20 degrees C were applied to the pseudo-first order, pseudo-second order and Weber-Morris kinetic models. The calculated sorption capacities (q(e,cal)) and the rate constant of the first order adsorption (k(1)) were determined. The pseudo-second order kinetic constants (k(2)) and capacities were calculated from the plots of t/q(t) vs. t, 1/q(t) vs. 1/t, 1/t vs. 1/q(t) and q(t)/t vs. q(t) for type 1, type 2, type 3 and type 4 of the pseudo-second order expression, respectively. The influence of phase contact time, solution pH and temperature on tartrazine removal was also discussed. The FTIR spectra of pure anion exchangers and those loaded with tartrazine were recorded, too.

  16. Purification of polar compounds from Radix isatidis using conventional C18 column coupled with polar-copolymerized C18 column.

    Science.gov (United States)

    Zeng, Jing; Guo, Zhimou; Xiao, Yuansheng; Wang, Chaoran; Zhang, Xiuli; Liang, Xinmiao

    2010-11-01

    Regarding hydrophilic interaction chromatography and normal phase liquid chromatography, RPLC is another choice used to separate polar compounds with the improvement of polar-modified C18 stationary phase. In this study, a method using conventional C18 column coupled with polar-copolymerized C18 column was successfully developed for the separation and purification of polar compounds from Radix isatidis, which is one of the most commonly used traditional Chinese medicines (TCMs). An XTerra MS C18 column was used to fractionate the extract of R. isatidis and a homemade polar-copolymerized C18 column was utilized for the final purification due to its good separation selectivity and high resolution for polar compounds. The established purification system demonstrated good orthogonality for the polar compounds. As a result, ten compounds were purified and three of them were identified as 3-methyl-5-vinyloxazolidin-2-one (compound A), 5-hydroxymethyl-2-furaldehyde (compound B) and 3-methylfuran-2-carboxylic acid (compound G) based on the MS, IR and extensive NMR data, respectively. It was demonstrated to be a feasible and powerful technique for the purification of polar compounds under RPLC mode and more chemical information of TCMs will be obtained to interpret the efficiency of TCMs.

  17. An improved anion-exchange high-performance liquid chromatography method for measuring oxidized form of LDLs in human plasma.

    Science.gov (United States)

    Kitano, Soichi; Higashimoto, Yuichiro; Harada, Shoji; Sano, Masaru; Kurata, Tsunehiko; Yamaguchi, Yu; Kunitomo, Masaru; Haginaka, Jun; Yamagishi, Sho-ichi

    2010-09-01

    Circulating oxidized low-density lipoproteins (LDLs) (ox-LDLs) could be a sensitive marker to predict future cardiovascular events. However, a method to evaluate oxidized forms of LDLs systemically in human plasma is not yet established. In this study, we developed a novel and convenient high-performance liquid chromatography (HPLC) method for measuring ox-LDL levels in humans. Human plasma lipoproteins were separated by a modified HPLC method using a diethylaminoethyl-type anion-exchange gel column with stepwise elution. Ox-LDLs were detected by postcolumn reaction with a reagent containing cholesterol esterase and cholesterol oxidase. Particle size of each LDL fraction separated by HPLC was determined in 61 healthy subjects. Our HPLC method separated LDLs into three fractions, which were designated as LDL-1, LDL-2 and LDL-3, on the basis of their negative charges, with LDL-3 the most strongly retained fraction migrating fastest in the anodic direction, a property that reflects the net negative charge of the molecule. Western blot analysis revealed that apolipoprotein B100 in LDL-3 fraction was the most fragmented and oxidatively modified. When LDLs were oxidized in vitro by Cu2+ or 2,2-azo-bis (2-aminopropane)-2HCl or modified by various aldehydes, all of the LDL fractions migrated at the position of LDL-3. Further, among three fractions, particle size was smallest in LDL-3 fraction. Here, we developed a convenient HPLC method and identified LDL-3 as oxidized LDL fractions, although ox-LDLs were present in LDL-2 fraction, albeit lesser concentrations than in LDL-3 subfraction. Measuring ox-LDL levels in human plasma by this method may be useful to evaluate atherosclerotic disorders.

  18. Polyethylenimine modified poly(ethylene terephthalate) capillary channeled-polymer fibers for anion exchange chromatography of proteins.

    Science.gov (United States)

    Jiang, Liuwei; Jin, Yi; Marcus, R Kenneth

    2015-09-04

    Native poly(ethylene terephthalate) (PET) capillary-channeled polymer (C-CP) fibers have been previously studied as stationary phases for reversed phase and affinity protein separations. In this study, surface modified PET C-CP fibers were evaluated for the anion exchange separation of proteins. The native PET C-CP fibers were aminated using polyethylenimine (PEI) followed by a 1,4-butanediol diglycidyl ether (BUDGE) cross-linking step. Subsequent PEI/BUDGE treatments can be employed to further develop the polyamine layer on the fiber surfaces. The PEI densities of the modified fibers were quantified through the ninhydrin reaction, yielding values of 0.43-0.89μmolg(-1). The surface modification impact on column permeability was found to be 0.66×10(-11) to 1.33×10(-11)m(2), depending on the modification time and conditions. The dynamic binding capacities of the modified fiber media were determined to be 1.99-8.54mgmL(-1) bed volume, at linear velocities of 88-438cmmin(-1) using bovine serum albumin as the model protein. It was found that increasing the mobile phase linear velocity (up to 438cmmin(-1)) had no effect on the separation quality for a synthetic protein mixture, reflecting the lack of van Deemter C-term effects for the C-CP fiber phase. The low-cost, easy modification method and the capability of fast protein separation illustrate great potential in the use of PEI/BUDGE-modified PET C-CP fibers for high-throughput protein separation and downstream processing. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Alkaline degradation studies of anion exchange polymers to enable new membrane designs

    Science.gov (United States)

    Nunez, Sean Andrew

    Current performance targets for anion-exchange membrane (AEM) fuel cells call for greater than 95% alkaline stability for 5000 hours at temperatures up to 120 °C. Using this target temperature of 120 °C, an incisive 1H NMR-based alkaline degradation method to identify the degradation products of n-alkyl spacer tetraalkylammonium cations in various AEM polymers and small molecule analogs. Herein, the degradation mechanisms and rates of benzyltrimethylammonium-, n-alkyl interstitial spacer- and n-alkyl terminal pendant-cations are studied on several architectures. These findings demonstrate that benzyltrimethylammonium- and n-alkyl terminal pendant cations are more labile than an n-alkyl interstitial spacer cation and conclude that Hofmann elimination is not the predominant mechanism of alkaline degradation. Additionally, the alkaline stability of an n-alkyl interstitial spacer cation is enhanced when combined with an n-alkyl terminal pendant. Interestingly, at 120 °C, an inverse trend was found in the overall alkaline stability of AEM poly(styrene) and AEM poly(phenylene oxide) samples than was previously shown at 80 °C. Successive small molecule studies suggest that at 120 °C, an anion-induced 1,4-elimination degradation mechanism may be activated on styrenic AEM polymers bearing an acidic alpha-hydrogen. In addition, an ATR-FTIR based method was developed to assess the alkaline stability of solid membranes and any added resistance to degradation that may be due to differential solubilities and phase separation. To increase the stability of anion exchange membranes, Oshima magnesate--halogen exchange was demonstrated as a method for the synthesis of new anion exchange membranes that typically fail in the presence of organolithium or Grignard reagents alone. This new chemistry, applied to non-resinous polymers for the first time, proved effective for the n-akyl interstitial spacer functionalization of poly(phenylene oxide) and poly(styrene- co

  20. Diclofenac removal in urine using strong-base anion exchange polymer resins.

    Science.gov (United States)

    Landry, Kelly A; Boyer, Treavor H

    2013-11-01

    One of the major sources of pharmaceuticals in the environment is wastewater effluent of which human urine contributes the majority of pharmaceuticals. Urine source separation has the potential to isolate pharmaceuticals at a higher concentration for efficient removal as well as produce a nutrient byproduct. This research investigated the efficacy of using strong-base anion exchange polymer resins to remove the widely detected and abundant pharmaceutical, diclofenac, from synthetic human urine under fresh and ureolyzed conditions. The majority of experiments were conducted using a strong-base, macroporous, polystyrene resin (Purolite A520E). Ion-exchange followed a two-step removal rate with rapid removal in 1 h and equilibrium removal in 24 h. Diclofenac removal was >90% at a resin dose of 8 mL/L in both fresh and ureolyzed urine. Sorption of diclofenac onto A520E resin was concurrent with desorption of an equivalent amount of chloride, which indicates the ion-exchange mechanism is occurring. The presence of competing ions such as phosphate and citrate did not significantly impact diclofenac removal. Comparisons of three polystyrene resins (A520E, Dowex 22, Dowex Marathon 11) as well as one polyacrylic resin (IRA958) were conducted to determine the major interactions between anion exchange resin and diclofenac. The results showed that polystyrene resins provide the highest level of diclofenac removal due to electrostatic interactions between quaternary ammonium functional groups of resin and carboxylic acid of diclofenac and non-electrostatic interactions between resin matrix and benzene rings of diclofenac. Diclofenac was effectively desorbed from A520E resin using a regeneration solution that contained 4.5% (m/m) NaCl in an equal-volume mixture of methanol and water. The greater regeneration efficiency of the NaCl/methanol-water mixture over the aqueous NaCl solution supports the importance of non-electrostatic interactions between resin matrix and benzene rings

  1. Golgi-associated anion exchanger, AE2:identification, cell type specific targeting and structural role in the Golgi complex

    OpenAIRE

    Holappa, K. (Katja)

    2004-01-01

    Abstract Anion exchanger 2 (AE2) is a member of the anion exchanger gene family, which includes three additional members, AE1, AE3, and AE4. They are also known as Na+-independent Cl-/HCO3- exchangers, and their major function is to regulate intracellular pH and chloride concentration. All four isoforms have several N-terminally truncated variants that are often expressed cell type specifically. Red blood cells express the full-length AE1 isoform that interacts with ankyrin, an adapter pro...

  2. Anion-exchange membranes derived from quaternized polysulfone and exfoliated layered double hydroxide for fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wan; Liang, Na; Peng, Pai; Qu, Rong; Chen, Dongzhi; Zhang, Hongwei, E-mail: hanqiujiang@163.com

    2017-02-15

    Layered double hydroxides (LDH) are prepared by controlling urea assisted homogeneous precipitation conditions. Morphology and crystallinity of LDHs are confirmed by X-ray diffraction and scanning electron microscope. After LDHs are incorporated into quaternized polysulfone membranes, transmission electron microscope is used to observe the exfoliated morphology of LDH sheets in the membranes. The properties of the nanocomposite membranes, including water uptake, swelling ratio, mechanical property and ionic conductivity are investigated. The nanocomposite membrane containing 5% LDH sheets shows more balanced performances, exhibiting an ionic conductivity of 2.36×10{sup −2} S cm{sup −1} at 60 °C. - Graphical abstract: Anion-exchange membrane based on quaternized polysulfone and exfoliated layered double hydroxide is optically transparent and has good ionic properties.

  3. An improved, computer-based, on-line gamma monitor for plutonium anion exchange process control

    International Nuclear Information System (INIS)

    Pope, N.G.; Marsh, S.F.

    1987-06-01

    An improved, low-cost, computer-based system has replaced a previously developed on-line gamma monitor. Both instruments continuously profile uranium, plutonium, and americium in the nitrate anion exchange process used to recover and purify plutonium at the Los Alamos Plutonium Facility. The latest system incorporates a personal computer that provides full-feature multichannel analyzer (MCA) capabilities by means of a single-slot, plug-in integrated circuit board. In addition to controlling all MCA functions, the computer program continuously corrects for gain shift and performs all other data processing functions. This Plutonium Recovery Operations Gamma Ray Energy Spectrometer System (PROGRESS) provides on-line process operational data essential for efficient operation. By identifying abnormal conditions in real time, it allows operators to take corrective actions promptly. The decision-making capability of the computer will be of increasing value as we implement automated process-control functions in the future. 4 refs., 6 figs

  4. Determination of uranium isotopes in environmental samples by anion exchange in sulfuric and hydrochloric acid media.

    Science.gov (United States)

    Popov, L

    2016-09-01

    Method for determination of uranium isotopes in various environmental samples is presented. The major advantages of the method are the low cost of the analysis, high radiochemical yields and good decontamination factors from the matrix elements, natural and man-made radionuclides. The separation and purification of uranium is attained by adsorption with strong base anion exchange resin in sulfuric and hydrochloric acid media. Uranium is electrodeposited on a stainless steel disk and measured by alpha spectrometry. The analytical method has been applied for the determination of concentrations of uranium isotopes in mineral, spring and tap waters from Bulgaria. The analytical quality was checked by analyzing reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Synthesis and Characterization of Stable Anion Exchange Membranes: The Addition of Electron-withdrawing Group

    Directory of Open Access Journals (Sweden)

    Gülşen ALBAYRAK ARI

    2016-10-01

    Full Text Available Anion exchange membranes (AEM based on poly(2,6-dimethyl-1,4-phenylene oxide (PPO were used as polymer electrolyte membrane for fuel cell applications. The membranes were prepared via bromination, quaternization and nitration reactions and their fuel cell-related properties (water uptake, ion exchange capacity, ionic conductivity were determined. Also, the structures and thermal properties were studied with Fourier transform infrared spectroscopy (FTIR, Size exclusion chromatography (SEC and Differential scanning calorimetry (DSC. Nitration of quaternized PPO (Q-PPO leaded to a decrease in water uptake and ion exchange capacity of the AEM. However, Q-PPO membrane treated with nitration reaction (NO2-Q-PPO exhibited a significant alkaline stability compared to quaternized PPO (Q-PPO.   The results indicated that the addition of electron-withdrawing group, such as nitro, into the structure in order to improve in alkaline stability is a promising new route for preparation alkaline stable AEM membranes.

  6. Characterization of anion exchange ionomers in hybrid polymer electrolyte fuel cells.

    Science.gov (United States)

    Unlü, Murat; Zhou, Junfeng; Anestis-Richard, Irene; Kohl, Paul A

    2010-12-17

    Anion exchange ionomers (AEI) synthesized here were characterized by use of a novel fuel cell configuration. The new analysis method involves assembling the AEI electrode of interest as the cathode in a hybrid, acid/alkaline, fuel cell configuration. The hybrid cell includes a conventional proton conducting anode/membrane half-cell along with the anionic conductor of interest at the cathode. Electrochemical impedance spectroscopy and voltammetry were used to evaluate the performance of the hybrid AEI-containing fuel cell with H₂ and O₂. In particular, the AEI electrode response in impedance spectroscopy was easily identified because the contributions from other components are largely minimized in the presented hybrid cell configuration. The properties of ionomers used in the AEI electrode were shown to have a substantial effect on the electrode performance. Low catalyst utilization, due to high water uptake and low conductivity, was identified as the major causes of poor performance in AEI electrodes.

  7. Composite anion-exchangers modified with nanoparticles of hydrated oxides of multivalent metals

    Science.gov (United States)

    Maltseva, T. V.; Kolomiets, E. O.; Dzyazko, Yu. S.; Scherbakov, S.

    2018-02-01

    Organic-inorganic composite ion-exchangers based on anion exchange resins have been obtained. Particles of one-component and two-component modifier were embedded using the approach, which allows us to realize purposeful control of a size of the embedded particles. The approach is based on Ostwald-Freundlich equation, which was adapted to deposition in ion exchange matrix. The equation was obtained experimentally. Hydrated oxides of zirconium and iron were applied to modification, concentration of the reagents were varied. The embedded particles accelerate sorption, the rate of which is fitted by the model equation of chemical reactions of pseudo-second order. When sorption of arsenate ions from very diluted solution (50 µg dm-3) occurs, the composites show higher distribution coefficients comparing with the pristine resin.

  8. Anion Exchange in II-VI Semiconducting Nanostructures via Atomic Templating

    Science.gov (United States)

    Agarwal, Rahul; Krook, Nadia M.; Ren, Ming-Liang; Tan, Liang Z.; Liu, Wenjing; Rappe, Andrew M.; Agarwal, Ritesh

    2018-03-01

    Controlled chemical transformation of nanostructures is a promising technique to obtain precisely designed novel materials which are difficult to synthesize otherwise. We report high-temperature vapor phase anion exchange reactions to chemically transform II-VI semiconductor nanostructures (100-300 nm length scale) while retaining the single crystallinity, crystal structure, morphology and even defect distribution of the parent material via atomic templating. The concept of atomic templating is employed to obtain kinetically controlled, thermodynamically metastable structural phases such as zincblende CdSe and CdS from zincblende CdTe upon complete chemical replacement of Te with Se or S. The underlying transformation mechanisms are explained through first-principles density functional theory calculations. Atomic templating is a unique path to independently tune materials phase and composition at the nanoscale allowing synthesis of novel materials.

  9. Cobalt sulfide aerogel prepared by anion exchange method with enhanced pseudocapacitive and water oxidation performances

    Science.gov (United States)

    Gao, Qiuyue; Shi, Zhenyu; Xue, Kaiming; Ye, Ziran; Hong, Zhanglian; Yu, Xinyao; Zhi, Mingjia

    2018-05-01

    This work introduces the anion exchange method into the sol-gel process for the first time to prepare a metal sulfide aerogel. A porous Co9S8 aerogel with a high surface area (274.2 m2 g‑1) and large pore volume (0.87 cm3 g‑1) has been successfully prepared by exchanging cobalt citrate wet gel in thioacetamide and subsequently drying in supercritical ethanol. Such a Co9S8 aerogel shows enhanced supercapacitive performance and catalytic activity toward oxygen evolution reaction (OER) compared to its oxide aerogel counterpart. High specific capacitance (950 F g‑1 at 1 A g‑1), good rate capability (74.3% capacitance retention from 1 to 20 A g‑1) and low onset overpotential for OER (220 mV) were observed. The results demonstrated here have implications in preparing various sulfide chalcogels.

  10. Adsorption of Monobutyl Phthalate from Aqueous Phase onto Two Macroporous Anion-Exchange Resins

    Directory of Open Access Journals (Sweden)

    Zhengwen Xu

    2014-01-01

    Full Text Available As new emerging pollutants, phthalic acid monoesters (PAMs pose potential ecological and human health risks. In the present study, adsorption performance of monobutyl phthalate (MBP onto two macroporous base anion-exchange resins (D-201 and D-301 was discussed. It was found that the adsorption isotherms were best fitted by the Langmuir equation while the adsorption kinetics were well described by pseudo-first-order model. Analyses of sorption isotherms and thermodynamics proved that the adsorption mechanisms for DBP onto D-201 were ion exchange. However, the obtained enthalpy values indicate that the sorption process of MBP onto D-301 is physical adsorption. The equilibrium adsorption capacities and adsorption rates of DBP on two different resins increased with the increasing temperature of the solution. D-301 exhibited a higher adsorption capacity of MBP than D-201. These results proved that D-301, as an effective sorbent, can be used to remove phthalic acid monoesters from aqueous solution.

  11. Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes

    Science.gov (United States)

    Narayan, Sri R.; Yen, Shiao-Ping S.; Reddy, Prakash V.; Nair, Nanditha

    2012-01-01

    Polymer electrolyte membranes that conduct hydroxide ions have potential use in fuel cells. A variety of polystyrene-based quaternary ammonium hydroxides have been reported as anion exchange fuel cell membranes. However, the hydrolytic stability and conductivity of the commercially available membranes are not adequate to meet the requirements of fuel cell applications. When compared with commercially available membranes, polystyrene-imidazolium alkaline membrane electrolytes are more stable and more highly conducting. At the time of this reporting, this has been the first such usage for imidazolium-based polymeric materials for fuel cells. Imidazolium salts are known to be electrochemically stable over wide potential ranges. By controlling the relative ratio of imidazolium groups in polystyrene-imidazolium salts, their physiochemical properties could be modulated. Alkaline anion exchange membranes based on polystyrene-imidazolium hydroxide materials have been developed. The first step was to synthesize the poly(styrene-co-(1-((4-vinyl)methyl)-3- methylimidazolium) chloride through a free-radical polymerization. Casting of this material followed by in situ treatment of the membranes with sodium hydroxide solutions provided the corresponding hydroxide salts. Various ratios of the monomers 4-chloromoethylvinylbenzine (CMVB) and vinylbenzine (VB) provided various compositions of the polymer. The preferred material, due to the relative ease of casting the film, and its relatively low hygroscopic nature, was a 2:1 ratio of CMVB to VB. Testing confirmed that at room temperature, the new membranes outperformed commercially available membranes by a large margin. With fuel cells now in use at NASA and in transportation, and with defense potential, any improvement to fuel cell efficiency is a significant development.

  12. Trace adsorption of positively charged proteins onto Sepharose FF and Sepharose FF-based anion exchangers.

    Science.gov (United States)

    Yu, Lin-Ling; Sun, Yan

    2012-08-31

    Agarose-based matrices have been widely used in ion exchange chromatography (IEC). We have herein observed that positively charged proteins (lysozyme and cytochrome c) are adsorbed on the agarose-based anion-exchangers (Q and DEAE Sepharose FF gels) in a capacity of 10-40 μg/mL. In contrast, negatively charged protein (bovine serum albumin) is not adsorbed to Sepharose FF and SP Sepharose FF gels. Elemental analysis of the gel indicated that the residual anionic sulfate groups in agarose would have worked as the cation exchange groups for the positively charged proteins. The trace adsorption behavior of lysozyme onto Sepharose FF and Sepharose FF-based anion exchangers was studied and the effects of NaCl concentration and cation group density on the adsorption were examined for better understanding of the trace adsorption in chromatographic processes. At NaCl concentrations less than 0.05 mol/L, which is the normal adsorption condition in IEC, the trace adsorption kept at a high level, so this trace adsorption cannot be avoided in the ionic strength range of routine IEC operations. Grafting poly(ethylenimine) (PEI) chain of 60 kDa to a cation group density of 700 mmol/L could reduce the adsorption capacity to about 20 μg/mL, but further reduction was not possible by increasing the cation group density to 1200 mmol/L. Therefore, attentions need to be paid to the phenomenon in protein purification practice using agarose-based matrices. The research is expected to call attentions to the trace adsorption on agarose-based matrices and to the importance in the selection of the suitable solid matrices in the production of high-purity protein products in large-scale bioprocesses. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Ammonium Bicarbonate Transport in Anion Exchange Membranes for Salinity Gradient Energy

    KAUST Repository

    Geise, Geoffrey M.

    2013-09-17

    Many salinity gradient energy technologies such as reverse electrodialysis (RED) rely on highly selective anion transport through polymeric anion exchange membranes. While there is considerable interest in using thermolytic solutions such as ammonium bicarbonate (AmB) in RED processes for closed-loop conversion of heat energy to electricity, little is known about membrane performance in this electrolyte. The resistances of two commercially available cation exchange membranes in AmB were lower than their resistances in NaCl. However, the resistances of commercially available anion exchange membranes (AEMs) were much larger in AmB than in NaCl, which would adversely affect energy recovery. The properties of a series of quaternary ammonium-functionalized poly(phenylene oxide) and Radel-based AEMs were therefore examined to understand the reasons for increased resistance in AmB to overcome this performance penalty due to the lower mobility of bicarbonate, 4.59 × 10-4 cm2/(V s), compared to chloride, 7.90 × 10-4 cm2/(V s) (the dilute aqueous solution mobility ratio of HCO3 - to Cl- is 0.58). Most membrane resistances were generally consistent with the dilute solution mobilities of the anions. For a few key samples, however, increased water uptake in AmB solution reduced the ionic resistance of the polymer compared to its resistance in NaCl solution. This increased water uptake was attributed to the greater hydration of the bicarbonate ion compared to the chloride ion. The increased resistance due to the use of bicarbonate as opposed to chloride ions in AEMs can therefore be mitigated by designing polymers that swell more in AmB compared to NaCl solutions, enabling more efficient energy recovery using AmB thermolytic solutions in RED. © 2013 American Chemical Society.

  14. Determination of sucralose in Splenda and a sugar-free beverage using high-performance anion-exchange chromatography with pulsed amperometric detection.

    Science.gov (United States)

    Hanko, Valoran P; Rohrer, Jeffrey S

    2004-07-14

    Sucralose is a chlorinated carbohydrate nonnutritive sweetener of food and beverage products. The determination of sucralose in food and beverages is important to ensure consistency in product quality. Sucralose was determined in two commercial products without sample preparation using high-performance anion-exchange (HPAE) chromatography coupled with pulsed amperometric detection (PAD). Sucralose was determined with a 10 min isocratic separation. To determine sucralose and other carbohydrates (e.g., dextrose) simultaneously, a gradient separation was developed. The linear range of electrochemical response extended over 3 orders of magnitude, from 0.01 (LOD) to 40 microM (16 microg/mL; 25 microL injection). High precision, high spike recovery, and method ruggedness were observed for both samples.

  15. Capacitive Substrate Coupling of Row–Column-Addressed 2-D CMUT Arrays

    DEFF Research Database (Denmark)

    Engholm, Mathias; Bouzari, Hamed; Jensen, Jørgen Arendt

    2016-01-01

    Row–column-addressed CMUT arrays suffer from low receive sensitivity of the bottom elements due to a capacitive coupling to the substrate. The capacitive coupling increases the parasitic capacitance. A simple approach to reduce the parasitic capacitance is presented, which is based on depleting...... of the semiconductor substrate can be sustained for at least 10 minutes making it applicable for row–column-addressed CMUT arrays for ultrasonic imaging. Theoretically the reduced parasitic capacitance indicates that the receive sensitivity of the bottom elements can be increased by a factor of 2:1....

  16. THE SORPTION EXTRACTION FEATURES OF KARMOAZONATE MERCURY(I COMPLE X BY ANION EXCHANGER AV-17-8 SURFACE

    Directory of Open Access Journals (Sweden)

    Н. M. Guzenko

    2014-11-01

    Full Text Available The dynamic and kinetic curves were analyzed, they were obtained by karmoazonate mercury(I complex extraction by anion exchanger AV-17-8 surface, and also calculated values of sorption process speed factor have allowed to establish the features of the adsorption layers formation on the resin surface.

  17. Studies on the thermal and radiolytic resistance of an anion exchanger with benzimidazole functional groups in nitric acid solution

    International Nuclear Information System (INIS)

    Iwasa, Satoru; Murata, Kiyoshi; Takeda, Kunihiko; Arai, Tsuyoshi; Wei, Y.Z.; Kumagai, Mikio

    2001-01-01

    Thermal and radiolytic resistance of AR-01R anion exchanger containing benzimidazole groups as exchange sites in nitric acid solution has been studied. Changes in its exchange capacity (EC), structure and shape were investigated and compared with those of a commercial Amberlite IRA-900 anion exchanger with quaternary ammonium group. Compared to the IRA-900, the AR-01R anion exchanger showed significantly higher thermal resistance and its decrease in EC was less than 10% after immersion in 9 mol·dm -3 solution for 72 h. On the other hand, it was found that the EC decrease of these two anion exchangers induced by γ-ray irradiation was almost the same; their EC decreased by 20-25% after irradiation in 9 mol·dm -3 HNO 3 solution at room temperature with absorption dose of 3.0 MGy. The change of the strong-base benzimidazole group to weak-base benzimidazole group in AR-01 was found to be the main damage by heat and γ-ray irradiation. (author)

  18. Development and characterization of direct ethanol fuel cells using alkaline anion-exchange membranes

    Science.gov (United States)

    Lim, Peck Cheng

    2009-08-01

    Alkaline membrane fuel cell (AMFC) is a relatively new fuel cell technology that is generating considerable interests. It offers the electrocatalytic advantages of conventional alkaline fuel cells, and the manufacturing and cost advantages of solid polymer electrolyte fuel cells. This project was carried out to develop and characterize high performance membrane electrode assemblies (MEAs) for all-solid-state AMFCs. The primary fuel of interests is ethanol, but hydrogen was used in the development stages to facilitate the diagnostic and evaluation of the fuel cell performance. In the preliminary investigation, AMFC was assembled using off-the-shelf electrodes and anion-exchange membrane (AEM). It was found that the performance of AMFC operating on ethanol fuel was limited by a large high-frequency resistance (HFR) value. The advantage of using non-toxic ethanol fuel was also compromised by the need to add hydrazine and potassium hydroxide to the fuel blend. Subsequently, a high performance MEA was developed for an all-solid-state AMFC, in which liquid electrolyte or other additives were not required during the operation of the fuel cell. Ionomer was incorporated in the formulation of catalyst ink, and the catalyst ink was directly coated on the anion-exchange membrane (AEM). An ionomer content of 20 wt.% was found to be the optimum amount required in the catalyst layers. It was demonstrated that the AMFC generated a maximum power density of 365 mW/cm2 and 213 mW/cm 2 with the use of hydrogen/oxygen and hydrogen/pure air, respectively. The performance of the AMFC was also found to be influenced by exposure to carbon dioxide in the air. Hence, the CCMs were pre-treated in potassium hydroxide solution and pure oxygen was used to condition the fuel cell to maximize the power output from the AMFCs. Although satisfactory performance was demonstrated in the AMFC, its stability during cell operation remains a major issue. The poor stability was attributed to degradation of

  19. Catalytic hydrodechlorination of triclosan using a new class of anion-exchange-resin supported palladium catalysts.

    Science.gov (United States)

    Han, Bing; Liu, Wen; Li, Jingwen; Wang, Jin; Zhao, Dongye; Xu, Rui; Lin, Zhang

    2017-09-01

    We prepared a new class of anion-exchange-resin supported Pd catalysts for efficient hydrodechlorination of triclosan in water. The catalysts were prepared through an initial ion-exchange uptake of PdCl 4 2- and subsequent reduction of Pd(II) to Pd(0) nanoparticles at ambient temperature. Two standard strong-base anion exchange resins (IRA-900 and IRA-958) with different matrices (polystyrene and polyacrylic) were chosen as the supports. SEM and TEM images showed that Pd(0) nanoparticles were evenly attached on the resin surface with a mean size of 3-5 nm. The resin supported Pd catalysts (Pd@IRA-900 and Pd@IRA-958) were able to facilitate rapid and complete hydrodechlorination of triclosan. At a Pd loading of 2.0 wt.%, the observed pseudo first-order rate constant (k obs ) was 1.25 ± 0.06 and 1.6 ± 0.1 L/g/min for Pd@IRA-900 and Pd@IRA-958, respectively. The catalysts were more resistant to Cl - poisoning and natural organic matter fouling than other supported-Pd catalysts. The presence of 10 mM NaCl suppressed the k obs value by 31% and 23% for Pd@IRA-900 and Pd@IRA-958, whereas the presence of humic acid at 30 mg/L as TOC lowered the rates by 28% and 27%, respectively. The better performance of Pd@IRA-958 was attributed to the polymeric matrix properties (i.e., hydrophobicity, pore size, and surface area) as well as Pd particle size. GC/MS analyses indicated that very low concentrations of chlorinated intermediates were detected in the early stage of the hydrodechlorination process, with 2-phenoxyphenol being the main byproduct. The catalysts can be repeatedly used in multiple operations without significant bleeding. The catalysts eliminate the need for calcination in preparing conventional supported catalysts, and the resin supports conveniently facilitate control of Pd loading and material properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Determination of trace lanthanide impurities in nuclear grade uranium by coupled-column liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lucy, C.A.; Gureli, L.; Elchuk, S. (Chalk River Lab., Ontario (Canada))

    1993-11-15

    Impurities such as Sm, Gd, Eu, and Dy will degrade the neutron economy of a nuclear reactor when present even at sub-parts-per-million levels, as a result of their high neutron absorption cross sections. Conventional determinations of lanthanide impurities in uranium require 0.5-100 g of uranium. A coupled-column chromatographic procedure has been developed which dramatically reduces the quantity of uranium required. The first column, a semipreparative reversed-phase column, removes the uranium matrix, while the second column, an analytical-scale cation exchange column, concentrates and separates the lanthanides prior to their postcolumn reaction detection with arsenazo III. The maximum loading of uranium onto the reversed-phase column is determined by the volume overload of the lanthanides rather than the concentration overload of the uranium. Using 20 mg of uranium, a detection limit of 0.02 [mu]g/g of U is achieved for Sm, Gd, Eu, and Dy with no interference from transition or alkaline earth metals present in the uranium. 39 refs., 5 figs., 2 tabs.

  1. Effects of Cationic Pendant Groups on Ionic Conductivity for Anion Exchange Membranes: Structure Conductivity Relationships

    Science.gov (United States)

    Kim, Sojeong; Choi, Soo-Hyung; Lee, Won Bo

    Anion exchange membranes(AEMs) have been widely studied due to their various applications, especially for Fuel cells. Previous proton exchange membranes(PEMs), such as Nafions® have better conductivity than AEMs so far. However, technical limitations such as slow electrode kinetics, carbon monoxide (CO) poisoning of metal catalysts, high methanol crossover and high cost of Pt-based catalyst detered further usages. AEMs have advantages to supplement its drawbacks. AEMs are environmentally friendly and cost-efficient. Based on the well-defined block copolymer, self-assembled morphology is expected to have some relationship with its ionic conductivity. Recently AEMs based on various cations, including ammonium, phosphonium, guanidinium, imidazolium, metal cation, and benzimidazolium cations have been developed and extensively studied with the aim to prepare high- performance AEMs. But more fundamental approach, such as relationships between nanostructure and conductivity is needed. We use well-defined block copolymer Poly(styrene-block-isoprene) as a backbone which is synthesized by anionic polymerization. Then we graft various cationic functional groups and analysis the relation between morphology and conductivity. Theoretical and computational soft matter lab.

  2. Onboard determination of submicromolar nitrate in seawater by anion-exchange chromatography with lithium chloride eluent.

    Science.gov (United States)

    Maruo, Masahiro; Doi, Takashi; Obata, Hajime

    2006-09-01

    Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide was very small because of low absorption, while its separation from the nitrate peak was good at high concentrations. Among the eluents tested, lithium chloride gave the best separation of nitrate from bromide. It was estimated that the lithium ion had the least potential for ion-pair formation with nitrate, and its retention time was prolonged compared with the retention times when using other cations; with bromide and nitrite, such an effect was not observed. The results of shipboard seawater nitrate determination by our method in the South Pacific Ocean and Antarctic Sea showed good agreement with those by the conventional photometric method using continuous flow.

  3. Recyclable cross-linked anion exchange membrane for alkaline fuel cell application

    Science.gov (United States)

    Hou, Jianqiu; Liu, Yazhi; Ge, Qianqian; Yang, Zhengjin; Wu, Liang; Xu, Tongwen

    2018-01-01

    Cross-linking can effectively solve the conductivity-swelling dilemma in anion exchange membranes (AEMs) but will generate solid wastes. To address this, we developed an AEM cross-linked via disulfide bonds, bearing quaternary ammonium groups, which can be easily recycled. The membrane (RC-QPPO) with IEC of 1.78 mmol g-1, when cross-linked, showed enhanced mechanical properties and good hydroxide conductivity (24.6 mS cm-1 at 30 °C). Even at higher IEC value (2.13 mmol g-1), it still has low water uptake, low swelling ratio and delivers a peak power density of 150 mW cm-2 at 65 °C. Exploiting the formation of disulfide bonds from -SH groups, the membrane can be readily cross-linked in alkaline condition and recycled by reversibly breaking disulfide bonds with dithiothreitol (DTT). The recycled membrane solution can be directly utilized to cast a brand-new AEM. By washing away the residual DTT with water and exposure to air, it can be cross-linked again and this process is repeatable. During the recycling and cross-linking processes, the membrane showed a slight IEC decrease of 5% due to functional group degradation. The strategy presented here is promising in enhancing AEM properties and reducing the impact of artificial polymers on the environment.

  4. Halloysite-derived nitrogen doped carbon electrocatalysts for anion exchange membrane fuel cells

    Science.gov (United States)

    Lu, Yaxiang; Wang, Lianqin; Preuß, Kathrin; Qiao, Mo; Titirici, Maria-Magdalena; Varcoe, John; Cai, Qiong

    2017-12-01

    Developing the low-cost, highly active carbonaceous materials for oxygen reduction reaction (ORR) catalysts has been a high-priority research direction for durable fuel cells. In this paper, two novel N-doped carbonaceous materials with flaky and rod-like morphology using the natural halloysite as template are obtained from urea nitrogen source as well as glucose (denoted as GU) and furfural (denoted as FU) carbon precursors, respectively, which can be directly applied as metal-free electrocatalysts for ORR in alkaline electrolyte. Importantly, compared with a benchmark Pt/C (20wt%) catalyst, the as-prepared carbon catalysts demonstrate higher retention in diffusion limiting current density (after 3000 cycles) and enhanced methanol tolerances with only 50-60mV negative shift in half-wave potentials. In addition, electrocatalytic activity, durability and methanol tolerant capability of the two N-doped carbon catalysts are systematically evaluated, and the underneath reasons of the outperformance of rod-like catalysts over the flaky are revealed. At last, the produced carbonaceous catalysts are also used as cathodes in the single cell H2/O2 anion exchange membrane fuel cell (AEMFC), in which the rod-like FU delivers a peak power density as high as 703 mW cm-2 (vs. 1106 mW cm-2 with a Pt/C benchmark cathode catalyst).

  5. The properties of anion-exchange resines in mixtures of organic solvents and water

    International Nuclear Information System (INIS)

    Naveh, J.

    1978-02-01

    The behaviour of anion-exchange resins in water and mixtures of organic solvents and water was studied with special reference to the swelling of the polymer and to the density and enthalpy changes accompanying the swelling. A linear dependence was found between the swelling of dry resin and 1/X (X being the nominal cross-linking percent of the polymer). This dependence is interpreted theoretically. The nominal cross-linking percent,defined by the quantity ratio of the components, is corrected for real cross-linking percent. For the swelling of the resin in dilute aqueous alcohols, a preference for the alcohol was found which is enhanced as the molecular weight of the alcohol increases. Moreover, for certain mole fractions, the preference of the perchlorate form of the resin is greater than that of the chloride form. The temperature dependence of the swelling was measured and the invasion of an electrolyte (LiCl), dissolved in the aqueous-organic phase, into the resine phase was determined. Contrary to what usually happens in pure aqueous phase, where the electrolyte is rejected in accordance with the Donnan law, an almost total invasion of the electrolyte into the resin phase occurs. (author)

  6. A series of poly(butylimidazolium) ionic liquid functionalized copolymers for anion exchange membranes

    Science.gov (United States)

    Ouadah, Amina; Xu, Hulin; Luo, Tianwei; Gao, Shuitao; Wang, Xing; Fang, Zhou; Jing, Chaojun; Zhu, Changjin

    2017-12-01

    A new series of ionic liquid functionalized copolymers for anion exchange membranes (AEM) is prepared. Poly(butylvinylimidazolium)(b-VIB) is copolymerized with para-methyl styrene (p-MS) by the radical polymerization formed block copolymers b-VIB/p-MS, which is crosslinked with poly(diphenylether bibenzimidazole) (DPEBI) providing the desired materials b-VIB/p-MS/DPEBI. Structures are characterized via H1NMR, FTIR spectra and elemental analysis. The b-VIB blocks offer the anion conduction function while DPEBI moieties contribute to enhancing other properties. The prepared membranes display chloride conductivity as high as 19.5 mS/cm at 25 °C and 69.2 mS/cm at 100 °C-higher than that of the commercial membrane tokuyuama A201-. Their hydroxide conductivity reaches 35.7 Scm-1 at 25 °C and 73.1 Scm-1 at 100 °C. The membranes showed a linear Arrhenius behavior in the anion conduction, low activation energies and distinguished nanophase separation of hydrophilic/hydrophobic regions by the transmission electron microscopy (TEM) studies. Thermal investigations using TGA and DSC confirm that the membranes are stable up to 250 °C. Particularly, drastically alkaline stability due to no decrease in the hydroxide conductivity after 168 h of treatment with 2M KOH.

  7. Novel fluoropolymer anion exchange membranes for alkaline direct methanol fuel cells.

    Science.gov (United States)

    Zhang, Yanmei; Fang, Jun; Wu, Yongbin; Xu, Hankun; Chi, Xianjun; Li, Wei; Yang, Yixu; Yan, Ge; Zhuang, Yongze

    2012-09-01

    A series of novel fluoropolymer anion exchange membranes based on the copolymer of vinylbenzyl chloride, butyl methacrylate, and hexafluorobutyl methacrylate has been prepared. Fourier transform infrared (FT-IR) spectroscopy and elemental analysis techniques are used to study the chemical structure and chemical composition of the membranes. The water uptake, ion-exchange capacity (IEC), conductivity, methanol permeability, and chemical stability of the membranes are also determined. The membranes exhibit high anionic conductivity in deionized water at 65 °C ranging from 3.86×10(-2) S cm(-1) to 4.36×10(-2) S cm(-1). The methanol permeability coefficients of the membranes are in the range of 4.21-5.80×10(-8) cm(2) s(-1) at 65 °C. The novel membranes also show good chemical and thermal stability. An open-circuit voltage of 0.7 V and a maximum power density of 53.2 mW cm(-2) of alkaline direct methanol fuel cell (ADMFC) with the membrane C, 1 M methanol, 1 M NaOH, and humidified oxygen are achieved at 65 °C. Therefore, these membranes have great potential for applications in fuel cell systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Synthesis and Structure-Property Relationships of Poly(sulfone)s for Anion Exchange Membranes

    Energy Technology Data Exchange (ETDEWEB)

    Yan, JL; Moore, HD; Hibbs, MR; Hickner, MA

    2013-10-05

    Membranes based on cationic polymers that conduct anions are important for enabling alkaline membrane fuel cells and other solid-state electrochemical devices that operate at high pH. Anion exchange membranes with poly(arylene ether sulfone) backbones are demonstrated by two routes: chloromethylation of commercially available poly(sulfone)s or radical bromination of benzylmethyl moieties in poly(sulfone)s containing tetramethylbisphenol A monomer residues. Polymers with tethered trimethylbenzyl ammonium moieties resulted from conversion of the halomethyl groups by quaternization with trimethyl amine. The water uptake of the chloromethylated polymers was dependent on the type of poly(sulfone) backbone for a given IEC. Bisphenol A-based Udel (R) poly(sulfone) membranes swelled in water to a large extent while membranes from biphenol-based Radel (R) poly(sulfone), a stiffer backbone than Udel, only showed moderate water uptake. The water uptake of cationic poly(sulfone)s was further reduced by synthesizing tetramethylbisphenol A and 4,4-biphenol-containing poly(sulfone) copolymers where the ionic groups were clustered on the tetramethylbisphenol A residues. The conductivity of all samples scaled with the bulk water uptake. The hydration number of the membranes could be increased by casting membranes from the ionic form polymers versus converting the halomethyl form cast polymers to ionic form in the solid state. (c) 2013 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2013, 51, 1790-1798, 2013

  9. Concentration and separation of trace metals from seawater using a single anion exchange bead

    International Nuclear Information System (INIS)

    Koide, M.; Lee, D.S.; Stallard, M.O.

    1984-01-01

    A technique has been developed for the quantitative adsorption of trace metals onto a single anion exchange bead. The application to the assay of trace metals in seawater was explored with the following radionuclides: 109 Cd, 103 Pd, 192 Ir, 195 Au, 237 Pu, and /sup 99m/Tc. The major ions, Na + , K + , Mg 2+ , and Ca 2+ exist primarily as positively charged species in seawater under nearly all conditions and did not interfere in the adsorption of anionic forms of trace metals onto the single bead. Three types of applications of the technique were investigated: (A) determination of metals in seawater by the direct adsorption onto a single bead without prior concentration, with or without a subsequent desorption from the bead (e.g., Cd, Zn); (B) determination of metals in seawater by the adsorption onto a single bead after a preconcentration step from several liters of seawater (e.g., Pd, Au, Ir), and (C) increasing the yield of Pu and Tc onto a single bead for improved sensitivity in mass spectrometric analyses

  10. Separation of Fluoride Ions in an Electrolytic Cell by Using an AnionExchange Membrane

    International Nuclear Information System (INIS)

    Fathurrachman; Sunardi

    2000-01-01

    Separation of fluoride ions in an electrolytic cell with an anionexchange membrane which is so-called an electrodialysis process has beenperformed. The experiment have been taken place in room temperature in anelectrolytic cell made by plexiglas consisted on anode and cathode chambersseparated by an anion exchange membrane in dimension of 4 x 4 cm. The carbonand stainless steel are applied as an anode and platinum as s' cathode. Theanolyte is a HNO 3 0.3 M solution, while a solution of NaF 0.3 M, and amixture of NaF 0.3 M containing uranyl nitrate solution for separating offluoride ions and uranium are used as a catholyte. The distance between theelectrode and the membrane is 1.5 cm and this distance is kept constant. Theparameters observed are the current voltage, cathode applied, and uraniumconcentration. For the solution without uranium, the results show that thefluoride ions transferred are around 50 % using carbon as a cathode for 3hours and the voltage of 10 volts, while for SS as a cathode are around 93 %.For the solution containing uranium, the fluoride ions transferred are around78 % for 3.5 hours and the uranium ions remain in the catholyte in which mostof them are as 8 yellow deposit of Na 2 U 2 O 7 on the cathode surface andothers are as a white precipitate of NaUF 5 on the bottom of the cathodechamber. (author)

  11. Synthesis and Characterization of Imidazolium Linear Bisphenol Polycarbonate Hydroxides for Anion Exchange Membrane.

    Science.gov (United States)

    Jang, Hohyoun; Hossain, Md Awlad; Lee, Soonho; Ha, Jaesung; Yoo, Jihoo; Kim, Kyungchul; Kim, Whangi

    2015-11-01

    A novel anion exchange membrane of imidazolium functionalized bisphenol polycarbonate was prepared for application in alkaline fuel cell. Di-imidazolium polycarbonate anionic membrane was synthesized by sequential interfacial polymerization, chloromethylation, substitution with 1-methylimidazole and ion exchange with 1.0 M KOH. Chloromethylation reaction was quantitative to achieve a high content of hydroxide ions. Introduction of conjugated imidazole ring in polymer plays an important role to improve both thermal and chemical stability. Bisphenol polycarbonate is a flexible polymer and shows a good solubility in polar organic solvent. The alkaline imidazolium bisphenol polycarbonate rendered an elevated molecular weight with excellent solubility in polar aprotic solvent. Different levels of substitution and ion exchange were investigated; the resulting membranes showed high ion exchange capacities (IECs) of up to 2.15 mmol g(-1). The imidazolium-functionalized copolymer membranes showed lower water affinity (14.2-42.8% at 30 degrees C) that satisfied an essential criterion for fuel cell application. The chemical structure of the imidazolium functionalized polycarbonate membrane was confirmed by 1H NMR spectroscopy, and also the membrane properties were evaluated by thermogravimetric analysis (TGA) and water uptake (WU), IEC and conductivity assessment. They exhibited hydroxide conductivity above 10(-2) S cm(-1) at room temperature and good chemical stability for up to five days without significant losses of ion conductivity.

  12. Alkaline anion exchange membrane water electrolysis: Effects of electrolyte feed method and electrode binder content

    Science.gov (United States)

    Cho, Min Kyung; Park, Hee-Young; Lee, Hye Jin; Kim, Hyoung-Juhn; Lim, Ahyoun; Henkensmeier, Dirk; Yoo, Sung Jong; Kim, Jin Young; Lee, So Young; Park, Hyun S.; Jang, Jong Hyun

    2018-04-01

    Herein, we investigate the effects of catholyte feed method and anode binder content on the characteristics of anion exchange membrane water electrolysis (AEMWE) to construct a high-performance electrolyzer, revealing that the initial AEMWE performance is significantly improved by pre-feeding 0.5 M aqueous KOH to the cathode. The highest long-term activity during repeated voltage cycling is observed for AEMWE operation in the dry cathode mode, for which the best long-term performance among membrane electrode assemblies (MEAs) featuring polytetrafluoroethylene (PTFE) binder-impregnated (5-20 wt%) anodes is detected for a PTFE content of 20 wt%. MEAs with low PTFE content (5 and 9 wt%) demonstrate high initial performance, rapid performance decay, and significant catalyst loss from the electrode during long-term operation, whereas the MEA with 20 wt% PTFE allows stable water electrolysis for over 1600 voltage cycles. Optimization of cell operating conditions (i.e., operation in dry cathode mode at an optimum anode binder content following an initial solution feed) achieves an enhanced water splitting current density (1.07 A cm-2 at 1.8 V) and stable long-term AEMWE performance (0.01% current density reduction per voltage cycle).

  13. Catalysis of deuterium transfer between liquid chloroform and water by anion-exchange resins

    International Nuclear Information System (INIS)

    Symons, E.A.; Bonnett, J.D.

    1985-01-01

    Anion-exchange resins in the hydroxide form have been successfully utilized for catalysis of deuterium transfer between water and liquid chloroform under stirred three-phase slurry conditions. In-solution rate constants for CDCl 3 /H 2 O exchange obtained at 15-35 0 C with liquid chloroform and 0.10 mol/liter NaOH solution under stirred conditions are in good agreement with literature data measured in the absence of bulk chloroform. At 25 0 C the resins tested, Rexyn 201(OH) and Ionac ASB-1P(OH), are ∼25x more effective per mole of - OH present than NaOH when they are used as whole beads. A further improvement is observed if the beads are crushed, but the latter state would be less suitable for commercial-scale application. The solubility of chloroform in the aqueous phase under isotope-exchange conditions was required to calculate the in-solution rate constants for exchange. A method was developed to obtain chloroform solubilities in 0.10 mol/liter NaOH solution and aqueous resin slurries; equilibrated solution samples were treated with 1 mol/liter NaOH to hydrolyze the dissolved CHCl 3 to chloride ion, which was then analyzed by specific ion electrode. 25 references, 2 figures, 1 table

  14. Carbon Supported Ag Nanoparticles as High Performance Cathode Catalyst for Anion Exchange Membrane Fuel Cell

    Directory of Open Access Journals (Sweden)

    Le eXin

    2013-09-01

    Full Text Available A solution phase-based nanocapsule method was successfully developed to synthesize non-precious metal catalyst - carbon supported Ag nanoparticles (Ag/C. XRD patterns and TEM image show Ag nanoparticles with a small average size (5.4 nm and narrow size distribution (2-9 nm are uniformly dispersed on the carbon black Vulcan XC-72 support. The intrinsic activity and pathway of oxygen reduction reaction (ORR on the Ag/C and commercial Pt/C were investigated using rotating ring disc electrode (RRDE tests at room temperature. The results confirmed that the 4-electron pathway of ORR proceeds on small Ag nanoparticles, and showed comparable ORR activities on the self-prepared Ag/C and a commercial Pt/C. A single H2-O2 anion exchange membrane fuel cell with the Ag/C cathode catalyst exhibited an open circuit potential of 0.98 V and a peak power density of 190 mW/cm2 at 80 oC.

  15. Magnetic graphitic carbon nitride anion exchanger for specific enrichment of phosphopeptides.

    Science.gov (United States)

    Zhu, Gang-Tian; He, Xiao-Mei; Chen, Xi; Hussain, Dilshad; Ding, Jun; Feng, Yu-Qi

    2016-03-11

    Anion-exchange chromatography (AEX) is one of the chromatography-based methods effectively being used for phosphopeptide enrichment. However, the development of AEX materials with high specificity toward phosphopeptides is still less explored as compared to immobilized metal affinity chromatography (IMAC) or metal oxide affinity chromatography (MOAC). In this work, magnetic graphitic carbon nitride (MCN) was successfully prepared and introduced as a promising AEX candidate for phosphopeptide enrichment. Due to the extremely abundant content of nitrogen with basic functionality on the surface, this material kept excellent retention for phosphopeptides at pH as low as 1.8. Benefiting from the large binding capacity at such low pH, MCN showed remarkable specificity to capture phosphopeptides from tryptic digests of standard protein mixtures as well as nonfat milk and human serum. In addition, MCN was also applied to selective enrichment of phosphopeptides from the tryptic digests of rat brain lysate and 2576 unique phosphopeptides were successfully identified. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Expression of Anion Exchanger 1 Sequestrates p16 in the Cytoplasm in Gastric, Colonic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Wei-Wei Shen

    2007-10-01

    Full Text Available p16INK4A (p16 binds to cyclin-dependent kinase 4/6, negatively regulates cell growth. Recent studies have led to an understanding of additional biologic functions for p16; however, the detailed mechanisms involved are still elusive. In this article, we show an unexpected expression of anion exchanger 1 (AEi in the cytoplasm in poorly, moderately differentiated gastric, colonic adenocarcinoma cells, in its interaction with p16, thereby sequestrating the protein in the cytoplasm. Genetic alterations of p16, AEi were not detectable. Forced expression of AEi in these cells sequestrated more p16 in the cytoplasm, whereas small interfering RNA-mediated silencing of AEi in the cells induced the release of p16 from the cytoplasm to the nucleus, leading to cell death, growth inhibition of tumor cells. By analyzing tissue samples obtained from patients with gastric, colonic cancers, we found that 83.33% of gastric cancers, 56.52% of colonic cancers coexpressed AEi, p16 in the cytoplasm. We conclude that AEi plays a crucial role in the pathogenesis of gastric, colonic adenocarcinoma, that p16 dysfunction is a novel pathway of carcinogenesis.

  17. Ion-exchange equilibrium of N-acetyl-D-neuraminic acid on a strong anionic exchanger.

    Science.gov (United States)

    Wu, Jinglan; Ke, Xu; Zhang, Xudong; Zhuang, Wei; Zhou, Jingwei; Ying, Hanjie

    2015-09-15

    N-acetyl-D-neuraminic acid (Neu5Ac) is a high value-added product widely applied in the food industry. A suitable equilibrium model is required for purification of Neu5Ac based on ion-exchange chromatography. Hence, the equilibrium uptake of Neu5Ac on a strong anion exchanger, AD-1 was investigated experimentally and theoretically. The uptake of Neu5Ac by the hydroxyl form of the resin occurred primarily by a stoichiometric exchange of Neu5Ac(-) and OH(-). The experimental data showed that the selectivity coefficient for the exchange of Neu5Ac(-) with OH(-) was a non-constant quantity. Subsequently, the Saunders' model, which took into account the dissociation reactions of Neu5Ac and the condition of electroneutrality, was used to correlate the Neu5Ac sorption isotherms at various solution pHs and Neu5Ac concentrations. The model provided an excellent fit to the binary exchange data for Cl(-)/OH(-) and Neu5Ac(-)/OH(-), and an approximate prediction of equilibrium in the ternary system Cl(-)/Neu5Ac(-)/OH(-). This basic information combined with the general mass transfer model could lay the foundation for the prediction of dynamic behavior of fixed bed separation process afterwards. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Synthesis, characterisation and anion exchange properties of copper, magnesium, zinc and nickel hydroxy nitrates

    International Nuclear Information System (INIS)

    Biswick, Timothy; Jones, William; Pacula, Aleksandra; Serwicka, Ewa

    2006-01-01

    Anion exchange reactions of four structurally related hydroxy salts, Cu 2 (OH) 3 NO 3 , Mg 2 (OH) 3 NO 3 , Ni 2 (OH) 3 NO 3 and Zn 3 (OH) 4 (NO 3 ) 2 are compared and trends rationalised in terms of the strength of the covalent bond between the nitrate group and the matrix cation. Powder X-ray diffraction (PXRD), Fourier-transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA) and elemental analysis are used to characterise the materials. Replacement of the nitrate anions in the zinc and copper salts with benzoate anions is possible although exchange of the zinc salt is accompanied by modification of the layer structure from one where zinc is exclusively six-fold coordinated to a structure where there is both six- and four-fold zinc coordination. Magnesium and nickel hydroxy nitrates, on the other hand, hydrolyse to their respective metal hydroxides. -- Graphical abstract: PXRD patterns of exchange products of (a) Zn 3 (OH) 4 (NO 3 ) 2 (b) Zn 5 (OH) 8 (NO 3 ) 2 .2H 2 O and (c) Cu 2 (OH) 3 NO 3 with benzoate anions

  19. Poly(vinylbenzylchloride) Based Anion-Exchange Blend Membranes (AEBMs): Influence of PEG Additive on Conductivity and Stability.

    Science.gov (United States)

    Kerres, Jochen A; Krieg, Henning M

    2017-06-16

    In view of the many possible applications such as fuel cells and electrolysers, recent interest in novel anion exchange membranes (AEMs) has increased significantly. However, their low conductivity and chemical stability limits their current suitability. In this study, the synthesis and characterization of several three- and four-component anion exchange blend membranes (AEBMs) is described, where the compositions have been systematically varied to study the influence of the AEBM's composition on the anion conductivities as well as chemical and thermal stabilities under strongly alkaline conditions. It was shown that the epoxide-functionalized poly(ethylene glycol)s that were introduced into the four-component AEBMs resulted in increased conductivity as well as a marked improvement in the stability of the AEBMs in an alkaline environment. In addition, the thermal stability of the novel AEBMs was excellent showing the suitability of these membranes for several electrochemical applications.

  20. Synthesis of free-standing metal sulfide nanoarrays via anion exchange reaction and their electrochemical energy storage application.

    Science.gov (United States)

    Xia, Xinhui; Zhu, Changrong; Luo, Jingshan; Zeng, Zhiyuan; Guan, Cao; Ng, Chin Fan; Zhang, Hua; Fan, Hong Jin

    2014-02-26

    Metal sulfides are an emerging class of high-performance electrode materials for solar cells and electrochemical energy storage devices. Here, a facile and powerful method based on anion exchange reactions is reported to achieve metal sulfide nanoarrays through a topotactical transformation from their metal oxide and hydroxide preforms. Demonstrations are made to CoS and NiS nanowires, nanowalls, and core-branch nanotrees on carbon cloth and nickel foam substrates. The sulfide nanoarrays exhibit superior redox reactivity for electrochemical energy storage. The self-supported CoS nanowire arrays are tested as the pseudo-capacitor cathode, which demonstrate enhanced high-rate specific capacities and better cycle life as compared to the powder counterparts. The outstanding electrochemical properties of the sulfide nanoarrays are a consequence of the preservation of the nanoarray architecture and rigid connection with the current collector after the anion exchange reactions.

  1. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A simple topological identification method for highly (3,12)-connected 3D MOFs showing anion exchange and luminescent properties.

    Science.gov (United States)

    Yang, Qing-Yuan; Li, Kang; Luo, Jian; Pan, Mei; Su, Cheng-Yong

    2011-04-14

    Reaction of a semi-rigid tripodal ligand 1,1',1''-(2,4,6-trimethylbenzene-1,3,5-triyl)tris(methylene)tripyridinium-4-olate) (TTP) with Ln(3+) (Ln = Eu, Gd) afforded rare (3,12)-connected metal-organic frameworks (MOFs). A topological simplification of such highly connected 3D MOFs on the basis of 2D CdI(2) (3,6)-nets is proposed. The luminescent and anion exchange properties of the compounds were determined.

  3. Anion exchange separation of the light lanthanoids with nitric acid-methyl alcohol mixed media at elevated temperature

    International Nuclear Information System (INIS)

    Usuda, S.; Magara, M.

    1987-01-01

    Anion exchange chromatography with nitric acid-methyl alcohol mixed media at elevated temperature was applied to mutual separation of the light lanthanoids, La, Ce, Pr, Nd and Pm. The individual elements could be effectively separated from each other, main fission products and actinoids with 0.01M HNO 3 -90% CH 3 OH or 0.5M HNO 3 -80% CH 3 OH eluent at 90 deg C. (author) 14 refs.; 3 tables

  4. Synthesis and Properties of Anion Exchangers Derived from Chloromethyl Styrene Codivinylbenzene and Their Use in Water Treatment

    Directory of Open Access Journals (Sweden)

    Hesham A. Ezzeldin

    2010-01-01

    Full Text Available Amination of vinylbenzyl chloride-divinylbenzene (VBC-DVB copolymers is an effective method for preparation of ion-exchange resins. Conventionally, the starting polymer is produced by chloromethylation of a styrene-divinylbenzene copolymer that utilizes chloromethyl methyl ether, a known carcinogen. An alterative approach is to copolymerize vinylbenzyl chloride with divinylbenzene to generate the necessary VBC-DVB. This method provides precise control over the density of the ion-exchange groups. The regiochemistry of the vinylbenzyl chloride methods was realized using solvent-ion exchange groups. In this investigation, an improved solvent system was found for the preparation of anion exchange resins by the vinylbenzyl chloride route. The effectiveness of amination of the intermediate VBC-DVB polymers with a variety of trimethylamine reagents was investigated, and ethanolic trimethylamine produced the highest degree of amination. These resulting ion-exchange polymers were characterized by a variety of techniques such as analytical titrations, nitrogen analysis, Fourier transform infrared spectroscopy and thermal gravimetric analysis. Testing of these copolymers for breakthrough was performed. The results indicate that these anion exchangers have a meaningful increase in thermal stability over commercial anionic exchange beads.

  5. Asymmetry of inverted-topology repeats in the AE1 anion exchanger suggests an elevator-like mechanism.

    Science.gov (United States)

    Ficici, Emel; Faraldo-Gómez, José D; Jennings, Michael L; Forrest, Lucy R

    2017-12-04

    The membrane transporter anion exchanger 1 (AE1), or band 3, is a key component in the processes of carbon-dioxide transport in the blood and urinary acidification in the renal collecting duct. In both erythrocytes and the basolateral membrane of the collecting-duct α-intercalated cells, the role of AE1 is to catalyze a one-for-one exchange of chloride for bicarbonate. After decades of biochemical and functional studies, the structure of the transmembrane region of AE1, which catalyzes the anion-exchange reaction, has finally been determined. Each protomer of the AE1 dimer comprises two repeats with inverted transmembrane topologies, but the structures of these repeats differ. This asymmetry causes the putative substrate-binding site to be exposed only to the extracellular space, consistent with the expectation that anion exchange occurs via an alternating-access mechanism. Here, we hypothesize that the unknown, inward-facing conformation results from inversion of this asymmetry, and we propose a model of this state constructed using repeat-swap homology modeling. By comparing this inward-facing model with the outward-facing experimental structure, we predict that the mechanism of AE1 involves an elevator-like motion of the substrate-binding domain relative to the nearly stationary dimerization domain and to the membrane plane. This hypothesis is in qualitative agreement with a wide range of biochemical and functional data, which we review in detail, and suggests new avenues of experimentation. © 2017 Ficici et al.

  6. Effect of the chemical structure of anion exchange resin on the adsorption of humic acid: behavior and mechanism.

    Science.gov (United States)

    Shuang, Chendong; Wang, Jun; Li, Haibo; Li, Aimin; Zhou, Qing

    2015-01-01

    Polystyrenic (PS) anion-exchange resin and polyacrylic (PA) anion-exchange resin were used to investigate the effect of resin chemical structure on the adsorption of humic acid (HA). Due to the rearrangement of HA to form layers that function as barricades to further HA diffusion, PS resin exhibited 12.4 times slower kinetics for the initial adsorption rate and 8.4 times for the diffusion constant in comparison to that of the PA resin. An HA layer and a spherical cluster of HA can be observed on the surface of the PS and PA resins after adsorption, respectively. The considerable difference in HA adsorption between the PS and PA resins was due to the difference in molecule shape for interaction with different resin structures, which can essentially be explained by the hydrophobicity and various interactions of the PS resin. A given amount of HA occupies more positively charged sites and hydrophobic sites on the PS resin than were occupied by the same amount of HA on the PA resin. Increased pH resulted in an increase of HA adsorption onto the PA resin but a decrease in adsorption onto PS resin, as the non-electrostatic adsorption led to electrostatic repulsion between the HA attached to the resin and the HA dissolved in solution. These results suggest higher rates of adsorption and higher regeneration efficiency for interaction of HA with more hydrophilic anion exchange materials. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Asymmetry of inverted-topology repeats in the AE1 anion exchanger suggests an elevator-like mechanism

    Science.gov (United States)

    Faraldo-Gómez, José D.

    2017-01-01

    The membrane transporter anion exchanger 1 (AE1), or band 3, is a key component in the processes of carbon-dioxide transport in the blood and urinary acidification in the renal collecting duct. In both erythrocytes and the basolateral membrane of the collecting-duct α-intercalated cells, the role of AE1 is to catalyze a one-for-one exchange of chloride for bicarbonate. After decades of biochemical and functional studies, the structure of the transmembrane region of AE1, which catalyzes the anion-exchange reaction, has finally been determined. Each protomer of the AE1 dimer comprises two repeats with inverted transmembrane topologies, but the structures of these repeats differ. This asymmetry causes the putative substrate-binding site to be exposed only to the extracellular space, consistent with the expectation that anion exchange occurs via an alternating-access mechanism. Here, we hypothesize that the unknown, inward-facing conformation results from inversion of this asymmetry, and we propose a model of this state constructed using repeat-swap homology modeling. By comparing this inward-facing model with the outward-facing experimental structure, we predict that the mechanism of AE1 involves an elevator-like motion of the substrate-binding domain relative to the nearly stationary dimerization domain and to the membrane plane. This hypothesis is in qualitative agreement with a wide range of biochemical and functional data, which we review in detail, and suggests new avenues of experimentation. PMID:29167180

  8. Synthesis of tunable-band-gap "Open-Box" halide perovskites by use of anion exchange and internal dissolution procedures.

    Science.gov (United States)

    Wu, Zhengcui; Wang, Baohua; He, Jian; Chen, Tao

    2016-01-01

    We demonstrate the synthesis of cuboid MAPbBr3 (MA=CH3NH3) microcrystals and subsequent conversion into open-box-like MAPb(Br(1-x)I(x))3 (0⩽x⩽1) microcrystals by anion exchange in MAI solution. During the substitution of Br(-) with I(-), the initial cuboid framework of MAPbBr3 crystals is retained. The preferential internal dissolution of MAPbBr3 due to the surface coverage and protection of MAPb(Br(1-x)I(x))3 induces voids inside the cuboid crystals, finally leading to open-box-like iodide-rich MAPb(Br(1-x)I(x))3. By controlling the degree of anion exchange, the intense light absorption of the product is able to be tuned in specific wavelengths throughout the visible range. This solution-phase anion exchange approach provides a synthetic strategy in designing sophisticated organolead halide perovskites structures as well as tuning the band gaps for further applications across a range of possible domains. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Radiochemical study of Re/W adsorption behavior on a strongly basic anion exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Gott, Matthew D. [Los Alamos National Laboratory, Los Alamos, NM (United States). Chemistry Div.; Missouri Univ., Columbia, MO (United States). Dept. of Chemistry; Ballard, Beau D.; Redman, Lindsay N. [Los Alamos National Laboratory, Los Alamos, NM (United States). Chemistry Div.; and others

    2014-07-01

    Rhenium-186g is a radionuclide with a high potential for therapeutic applications. It emits therapeutic β{sup -} particles accompanied by low energy γ-rays, which allows for in-vivo tracking of the radiolabeled compound and dosimetry estimates. The current reactor production pathway {sup 185}Re(n,γ){sup 186g}Re produces low specific activity {sup 186g}Re, thereby limiting its therapeutic application. Work is underway to develop an accelerator-based, charged particle induced production method for high specific activity {sup 186g}Re from targets of enriched {sup 186}W. To optimize the chemical {sup 186g}Re recovery method, batch studies have been performed to characterize the adsorption behavior of Re and W on a strongly basic anion exchange resin. An in-depth physicochemical profile was developed for the interaction of Re with resin material, which showed the reaction to be endothermic and spontaneous. Basic (NaOH) and acidic (HNO{sub 3}) matrices were used to determine the equilibrium distribution coefficients for Re and W. The resin exhibits the best affinity for Re at slightly basic conditions and little affinity above moderately acidic concentrations. Tungsten has low affinity for the resin above moderately basic concentrations. A study was performed to examine the effect of W concentration on Re adsorption, which showed that even a high ionic WO{sub 4}{sup 2-} strength of up to 1.9 mol kg{sup -1} does not significantly compromise ReO{sub 4}{sup -} retention on the resin. (orig.)

  10. The importance of OH − transport through anion exchange membrane in microbial electrolysis cells

    KAUST Repository

    Ye, Yaoli

    2018-01-11

    In two-chamber microbial electrolysis cells (MECs) with anion exchange membranes (AEMs), a phosphate buffer solution (PBS) is typically used to avoid increases in catholyte pH as Nernst equation calculations indicate that high pHs adversely impact electrochemical performance. However, ion transport between the chambers will also impact performance, which is a factor not included in those calculations. To separate the impacts of pH and ion transport on MEC performance, a high molecular weight polymer buffer (PoB), which was retained in the catholyte due to its low AEM transport and cationic charge, was compared to PBS in MECs and abiotic electrochemical half cells (EHCs). In MECs, catholyte pH control was less important than ion transport. MEC tests using the PoB catholyte, which had a higher buffer capacity and thus maintained a lower catholye pH (<8), resulted in a 50% lower hydrogen production rate (HPR) than that obtained using PBS (HPR = 0.7 m3-H2 m−3 d−1) where the catholyte rapidly increased to pH = 12. The main reason for the decreased performance using PoB was a lack of hydroxide ion transfer into the anolyte to balance pH. The anolyte pH in MECs rapidly decreased to 5.8 due to a lack of hydroxide ion transport, which inhibited current generation by the anode, whereas the pH was maintained at 6.8 using PBS. In abiotic tests in ECHs, where the cathode potential was set at −1.2 V, the HPR was 133% higher using PoB than PBS due to catholyte pH control, as the anolyte pH was not a factor in the performance. These results show that maintaining charge transfer to control anolyte pH is more important than obtaining a more neutral pH catholyte.

  11. The Effect of Ambient Carbon Dioxide on Anion-Exchange Membrane Fuel Cells.

    Science.gov (United States)

    Ziv, Noga; Mustain, William E; Dekel, Dario R

    2018-01-27

    Over the past 10 years, there has been a surge of interest in anion-exchange membrane fuel cells (AEMFCs) as a potentially lower cost alternative to proton-exchange membrane fuel cells (PEMFCs). Recent work has shown that AEMFCs achieve nearly identical performance to that of state-of-the-art PEMFCs; however, much of that data has been collected while feeding CO 2 -free air or pure oxygen to the cathode. Usually, removing CO 2 from the oxidant is done to avoid the detrimental effect of CO 2 on AEMFC performance, through carbonation, whereby CO 2 reacts with the OH - anions to form HCO 3 - and CO 3 2- . In spite of the crucial importance of this topic for the future development and commercialization of AEMFCs, unfortunately there have been very few investigations devoted to this phenomenon and its effects. Much of the data available is widely spread out and there currently does not exist a resource that researchers in the field, or those looking to enter the field, can use as a reference text that explains the complex influence of CO 2 and HCO 3 - /CO 3 2- on all aspects of AEMFC performance. The purpose of this Review is to summarize the experimental and theoretical work reported to date on the effect of ambient CO 2 on AEMFCs. This systematic Review aims to create a single comprehensive account of what is known regarding how CO 2 behaves in AEMFCs, to date, as well as identify the most important areas for future work in this field. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. New Anion-Exchange Resins for Improved Separations of Nuclear Materials

    International Nuclear Information System (INIS)

    Bartsch, Richard A.; Barr, Mary E.

    2001-01-01

    Improved separations of nuclear materials will have a significant impact upon a broad range of DOE activities. DOE-EM Focus Areas and Crosscutting Programs have identified improved methods for the extraction and recovery of radioactive metal ions from process, waste, and environmental waters as critical needs for the coming years. We propose to develop multifunctional anion-exchange resins that facilitate anion uptake by carefully controlling the structure of the anion receptor site. Our new ion-exchange resins interface the field of ion-specific chelating ligands with robust, commercial ion-exchange technology to provide materials which exhibit superior selectivity and kinetics of sorption and desorption. The following Focus Areas and Crosscutting Programs have described needs that would be favorably impacted by the new material: Efficient Separations and Processing - radionuclide removal from aqueous phases; Plutonium - Pu, Am or total alpha removal to meet regulatory requirement s before discharge to the environment; Plumes - U and Tc in groundwater, U, Pu, Am, and Tc in soils; Mixed Waste - radionuclide partitioning; High-Level Tank Waste - actinide and Tc removal from supernatants and/or sludges. The basic scientific issues which need to be addressed are actinide complex speciation along with modeling of metal complex/functional site interactions in order to determine optimal binding-site characteristics. Synthesis of multifunctionalized extractants and ion-exchange materials that implement key features of the optimized binding site, and testing of these materials, will provide feedback to the modeling and design activities. Resin materials which actively facilitate the uptake of actinide complexes from solution should display both improved selectivity and kinetic properties. The long-range implications of this research, however, go far beyond the nuclear complex. This new methodology of ''facilitated uptake'' could revolutionize ion-exchange technology

  13. Anion Exchanger 2 Regulates Dectin-1-Dependent Phagocytosis and Killing of Candida albicans.

    Directory of Open Access Journals (Sweden)

    Katia Urso

    Full Text Available Anion exchanger 2 (Ae2; gene symbol, Slc4a2 is a plasma membrane Cl-/HCO3- exchanger expressed in the gastrointestinal tract, kidney and bone. We have previously shown that Ae2 is required for the function of osteoclasts, bone resorbing cells of the macrophage lineage, to maintain homeostatic cytoplasmic pH and electroneutrality during acid secretion. Macrophages require endosomal acidification for pathogen killing during the process known as phagocytosis. Chloride is thought to be the principal ion responsible for maintaining electroneutrality during organelle acidification, but whether Cl-/HCO3- exchangers such as Ae2 contribute to macrophage function is not known. In this study we investigated the role of Ae2 in primary macrophages during phagocytosis. We find that Ae2 is expressed in macrophages where it regulates intracellular pH and the binding of Zymosan, a fungal cell wall derivative. Surprisingly, the transcription and surface expression of Dectin-1, the major phagocytic receptor for Candida albicans (C. albicans and Zymosan, is reduced in the absence of Ae2. As a consequence, Zymosan-induced Tnfα expression is also impaired in Ae2-deficient macrophages. Similar to Ae2 deficiency, pharmacological alkalinization of lysosomal pH with bafilomycin A decreases both Dectin-1 mRNA and cell surface expression. Finally, Ae2-deficient macrophages demonstrate defective phagocytosis and killing of the human pathogenic fungus C. albicans. Our results strongly suggest that Ae2 is a critical factor in the innate response to C. albicans. This study represents an important contribution to a better understanding of how Dectin-1 expression and fungal clearance is regulated.

  14. Human kidney anion exchanger 1 interacts with kinesin family member 3B (KIF3B)

    International Nuclear Information System (INIS)

    Duangtum, Natapol; Junking, Mutita; Sawasdee, Nunghathai; Cheunsuchon, Boonyarit; Limjindaporn, Thawornchai; Yenchitsomanus, Pa-thai

    2011-01-01

    Highlights: → Impaired trafficking of kAE1 causes distal renal tubular acidosis (dRTA). → The interaction between kAE1 and kinesin family member 3B (KIF3B) is reported. → The co-localization between kAE and KIF3B was detected in human kidney tissues. → A marked reduction of kAE1 on the cell membrane was observed when KIF3B was knockdown. → KFI3B plays an important role in trafficking of kAE1 to the plasma membrane. -- Abstract: Impaired trafficking of human kidney anion exchanger 1 (kAE1) to the basolateral membrane of α-intercalated cells of the kidney collecting duct leads to the defect of the Cl - /HCO 3 - exchange and the failure of proton (H + ) secretion at the apical membrane of these cells, causing distal renal tubular acidosis (dRTA). In the sorting process, kAE1 interacts with AP-1 mu1A, a subunit of AP-1A adaptor complex. However, it is not known whether kAE1 interacts with motor proteins in its trafficking process to the plasma membrane or not. We report here that kAE1 interacts with kinesin family member 3B (KIF3B) in kidney cells and a dileucine motif at the carboxyl terminus of kAE1 contributes to this interaction. We have also demonstrated that kAE1 co-localizes with KIF3B in human kidney tissues and the suppression of endogenous KIF3B in HEK293T cells by small interfering RNA (siRNA) decreases membrane localization of kAE1 but increases its intracellular accumulation. All results suggest that KIF3B is involved in the trafficking of kAE1 to the plasma membrane of human kidney α-intercalated cells.

  15. Rifampicin Induces Bicarbonate-Rich Choleresis in Rats: Involvement of Anion Exchanger 2.

    Science.gov (United States)

    Wang, Wei; Ren, Xiaofei; Cai, Yi; Chen, Lihong; Zhang, Weiping; Xu, Jianming

    2016-01-01

    Previous studies have shown that rifampicin induced choleresis, the mechanisms of which have not been described. The aim of this study was to investigate the mechanisms underlying in vivo rifampicin-induced choleresis. In one experimental set, rats were treated chronically with rifampicin on days 1, 3 and 7. Serum and biliary parameters were assayed, and mRNA and protein levels, as well as the locations of the hepatic export transporters were analyzed by real-time PCR, western blot and immunofluorescence. Ductular mass was evaluated immunohistochemically. In another experimental set, rats received an acute infusion of rifampicin. The amount of rifampicin in bile was detected using HPLC. Biliary parameters were monitored following intrabiliary retrograde fluxes of the Cl(-)/HCO3 (-) exchange inhibitor 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid (DIDS) or 5-nitro-2-(3-phenylpropylamino)benzoic acid (NPPB) in the infused rats. Biliary bicarbonate output increased in parallel to the augmented bile flow in response to rifampicin, and this effect was abolished with intrabiliary administration of DIDS, but not NPPB. The biliary secretion of rifampicin with increases in bile flow and biliary rifampicin in response to different infused doses of the antibiotic show no significant correlations. After rifampicin treatment, the expression level of anion exchanger 2 (AE2) increased, while the location of hepatic transporters did not change. However, RIF treatment did not increase ductular mass significantly. These results indicate that the increase in bile flow induced by rifampicin is mainly due to increased HCO3 (-) excretion mediated by increased AE2 protein expression and activity.

  16. Quaternized dimethylaminoethyl methacrylate strong base anion exchange fibers for As(V) adsorption

    International Nuclear Information System (INIS)

    Kavaklı, Cengiz; Akkaş Kavaklı, Pınar; Turan, Burcu Dila; Hamurcu, Aslı; Güven, Olgun

    2014-01-01

    N,N-Dimethylaminoethyl methacrylate (DMAEMA) grafted polyethylene/polypropylene (PE/PP) nonwoven fibers (DMAEMA-g-PE/PP) was prepared by radiation-induced graft polymerization. DMAEMA graft chains on nonwoven fibers were quaternized with dimethyl sulfate solution for the preparation of strong base anion exchange fibers (QDMAEMA-g-PE/PP). Fiber structures were characterized by FTIR, XPS and SEM techniques. The effect of solution pH, contact time, initial As(V) ion concentration and coexisting ions on the As(V) adsorption capacity of the QDMAEMA-g-PE/PP fibers were investigated by performing batch adsorption experiments. The adsorption of As(V) by QDMAEMA-g-PE/PP fibers was found to be independent on solution pH in the range 4.00–10.00. Kinetic experiments show that the As(V) adsorption rate was rapid and As(V) adsorption follows pseudo second-order kinetic model. As(V) adsorption equilibrium data were analyzed using Langmuir and Freundlich adsorption isotherm model equations. Langmuir and Freundlich adsorption isotherm models fitted the experimental data well. The maximum adsorption capacity (q max ) calculated from Langmuir isotherm was found to be 83.33 mg As(V)/g polymer at pH 7.00. The adsorbent was used for three cycles without significant loss of adsorption capacity. The adsorbed As(V) ions were desorbed effectively by a 0.1 M NaOH solution. - Highlights: • QDMAEMA-g-PE/PP fibers have high adsorption capacity for As(V) ions. • Adsorption of As(V) is independent on the solution pH over a wide range (4−10). • As(V) adsorption rate of QDMAEMA-g-PE/PP fibers is considerably fast. • The maximum adsorption capacity (q max ) was found to be 83.33 mg As(V)/g polymer

  17. Isolation of radioactive strontium from natural samples. Separation of strontium from alkaline and alkaline earth elements by means of mixed solvent anion exchange

    International Nuclear Information System (INIS)

    Grahek, Z.; Kosutic, K.; Lulic, S.; Kvastek, K.; Eskinja, I.

    1999-01-01

    This paper presents the results of studies which led to the procedures for the chromatographic separation of radioactive strontium from alkaline, earth-alkaline and other elements in natural samples, on columns filled with strong base anion exchangers using alcoholic solutions of nitric acid as eluents. It has been shown that potassium, caesium, calcium, barium, yttrium and strontium can be adsorbed on strong base anion exchangers of the Dowex and Amberlite type, which contain the quaternary ammonium group with nitrate as counter-ion, from solutions of nitric acid in alcohol. Adsorption strength increases in the order methanol 3 in methanol, while they are adsorbed from ethanol and propanol. The adsorption strength is influenced by the polarity of alcohol, by the concentration of nitrate and by pH. The strength with which strontium adsorbs on the exchangers increases in the interval from 0 to 0.25M NH 4 NO 3 in methanol, after which it starts to decrease. Strontium adsorbs to the exchangers from the alcoholic solution of ammonium nitrate twice as strongly as from the alcoholic solution of nitric acid, while a fraction of water in pure alcohol exceeding 10% prevents adsorption. In the mixture of alcohol and nitric acid, the adsorption strength for calcium and strontium increases with the increase of the volume fraction of alcohol with a lower dielectric constant. The rate and strength of adsorption of ions on the exchanger also increase in the series 0.25M HNO 3 in methanol 3 in ethanol 3 in 1-propanol for each individual ion, as well as in the Ca 3 in methanol, 0.25M HNO 3 in ethanol and 0.25M HNO 3 in propanol. Separation is also possible from alcohol mixtures. Strontium separation is most difficult from calcium, while the efficiency of separation increases with a decrease of the polarity of the used alcohol or alcohol mixture. The first group elements of the periodic table are not separated from each other in this way, while the elements of the second group are

  18. Cleanup and analysis of sugar phosphates in biological extracts by using solid phase extraction and anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Smith, Hans Peter; Cohen, A.; Buttler, T.

    1998-01-01

    A cleanup method based on anion-exchange solid-phase extraction (SPE) was developed to render biological extracts suitable for the analysis of hexose phosphates with a modified anion-exchange chromatography method and pulsed amperometric detection. The method was applied to cell extracts of Sacch......A cleanup method based on anion-exchange solid-phase extraction (SPE) was developed to render biological extracts suitable for the analysis of hexose phosphates with a modified anion-exchange chromatography method and pulsed amperometric detection. The method was applied to cell extracts...... of Saccharomyces cerevisiae obtained by using cold methanol as quenching agent and chloroform as extraction solvent. It was shown that pretreatment of the cell extract with SPE markedly improved the quality of the liquid chromatography analysis with recoveries of the sugar phosphates close to 100%. Furthermore...

  19. Guidelines for selecting weak-base versus strong-base anion-exchange resins for the recovery of chromate from cooling tower blowdown

    Energy Technology Data Exchange (ETDEWEB)

    Newman, J.; Reed, L.W.

    1980-01-01

    Guidelines for selecting weak-base versus strong-base anion-exchange resins for the recovery of chromate from cooling tower blowdown are given, together with actual operating data on large-scale industrial systems based on strong-base anion-exchange resins, data from a similar pilot system based on weak-base anion resin, and the chemical costs for operating both systems for a cooling tower blowdown containing 2500 ppm total dissolved solids and 20 ppm chromata.

  20. In-situ anion exchange fabrication of porous ZnO/ZnSe heterostructural microspheres with enhanced visible light photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hairui, E-mail: liuhairui1@126.com [College of Physics & Electrics Engineering, Henan Normal University, Henan Key Laboratory of Photovoltaic Materials, Xinxiang 453007 (China); Key Laboratory of Interface Science and Engineering in Advanced Materials (Taiyuan University of Technology), Ministry of Education, Taiyuan, Shanxi, 030024 (China); College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024 (China); Hu, Yanchun [College of Physics & Electrics Engineering, Henan Normal University, Henan Key Laboratory of Photovoltaic Materials, Xinxiang 453007 (China); He, Xia [Key Laboratory of Interface Science and Engineering in Advanced Materials (Taiyuan University of Technology), Ministry of Education, Taiyuan, Shanxi, 030024 (China); Jia, Husheng, E-mail: jia_husheng@126.com [Key Laboratory of Interface Science and Engineering in Advanced Materials (Taiyuan University of Technology), Ministry of Education, Taiyuan, Shanxi, 030024 (China); College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, Shanxi 030024 (China); Liu, Xuguang; Xu, Bingshe [Key Laboratory of Interface Science and Engineering in Advanced Materials (Taiyuan University of Technology), Ministry of Education, Taiyuan, Shanxi, 030024 (China)

    2015-11-25

    Porous ZnO microspheres were fabricated by an ultrasonic irradiation technique. Subsequently, through a facile in-situ anion exchange reaction between the ZnO microsphere and sodium selenite, spherical ZnO/ZnSe heterostructures with different ratios of the two components were fabricated. The as-obtained products were characterized by field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray (EDX) spectroscopy, transmission electron microscopy (TEM), X-ray diffraction (XRD), and UV–vis spectrometry. The results reveal that the secondary ZnSe nanoparticles are grown on the surface of pre-grown ZnO microspheres. Compared with pure ZnO microspheres, the ZnO/ZnSe hetero-microspheres show enhance visible-light photocatalytic activity for degradation of methylene blue (MB) and 4-nitrophenol (4-NP). The enhanced photocatalytic performance is attributed to fast separation and transport of photogenerated electrons and holes derived from the coupling effect of ZnSe and ZnO heterostructure. Photoluminescent spectra further indicate that the ZnO/ZnSe heterostructures greatly suppress the charge recombination of photogenerated electron–hole pairs, which would be beneficial to improve their photocatalytic activity. Finally, the photocatalytic mechanism of the ZnO/ZnSe heterostructures is proposed. - Graphical abstract: Porous ZnO/ZnSe heterostructures with different ratios of the two components were fabricated and present enhance visible-light photocatalytic activity for degradation of methylene blue (MB) and 4-nitrophenol (4-NP). The enhanced photocatalytic performance is attributed to fast separation and transport of photogenerated electrons and holes derived from the coupling effect of ZnSe and ZnO heterostructure. - Highlights: • Spherical ZnO/ZnSe porous composites were fabricated by in-situ anion exchange. • ZnO/ZnSe composites exhibited enhanced visible-light photocatalytic activity. • The matching band gap improves the separation of

  1. A review of post-column photochemical reaction systems coupled to electrochemical detection in HPLC.

    Science.gov (United States)

    Fedorowski, Jennifer; LaCourse, William R

    2010-01-04

    Post-column photochemical reaction systems have developed into a common approach for enhancing conventional methods of detection in HPLC. Photochemical reactions as a means of 'derivatization' have a significant number of advantages over chemical reaction-based methods, and a significant effort has been demonstrated to develop an efficient photochemical reactor. When coupled to electrochemical (EC) detection, the technique allows for the sensitive and selective determination of a variety of compounds (e.g., organic nitro explosives, beta-lactam antibiotics, sulfur-containing antibiotics, pesticides and insecticides). This review will focus on developments and methods using post-column photochemical reaction systems followed by EC detection in liquid chromatography. Papers are presented in chronological order to emphasize the evolution of the approach and continued importance of the application.

  2. New reversed phase-high performance liquid chromatographic method for selective separation of yttrium from all rare earth elements employing nitrilotriacetate complexes in anion exchange mode.

    Science.gov (United States)

    Dybczyński, Rajmund S; Kulisa, Krzysztof; Pyszynska, Marta; Bojanowska-Czajka, Anna

    2015-03-20

    Separation of Y from other rare earth elements (REE) is difficult because of similarity of its ionic radius to ionic radii of Tb, Dy and Ho. In the new RP-HPLC system with C18 column, tetra-n-butyl ammonium hydroxide (TBAOH) as an ion interaction reagent (IIR), nitrilotriacetic acid (NTA) as a complexing agent at pH=2.8-3.5, and post column derivatization with Arsenazo III, yttrium is eluted in the region of light REE, between Nd and Sm and is base line separated from Nd and Sm and even from promethium. Simple model employing literature data on complex formation of REE with NTA and based on anion exchange mechanism was developed to foresee the order of elution of individual REE. The model correctly predicted that lanthanides up to Tb will be eluted in the order of increasing Atomic Number (At.No.) but all heavier REE will show smaller retention factors than Tb. Concurrent UV/VIS detection at 658nm and the use of radioactive tracers together with γ-ray spectrometric measurements made possible to establish an unique elution order of elution of REE: La, Ce, Pr, Nd, Pm, Y, Sm, Er, Ho, Tm, Yb, Eu, Lu, Dy+Gd, Tb, Sc. The real place of Y however, in this elution series differs from that predicted by the model (Y between Sm and Eu). The method described in this work enables selective separation of Y from La, Ce, Pr, Nd, Pm, Sm and all heavier REE treated as a group. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. A tandem laboratory scale protein purification process using Protein A affinity and anion exchange chromatography operated in a weak partitioning mode.

    Science.gov (United States)

    Shamashkin, Michael; Godavarti, Ranga; Iskra, Timothy; Coffman, Jon

    2013-10-01

    A significant consequence of scaling up production of high titer monoclonal antibody (mAb) processes in existing facilities is the generation of in-process pools that exceed the capacity of storage vessels. A semi-continuous downstream process where columns and filters are linked and operated in tandem would eliminate the need for intermediate holding tanks. This study is a bench-scale demonstration of the feasibility of a tandem process for the purification of mAbs employing an affinity Protein A capture step, followed by a flow-through anion-exchange (AEX) step with the possibility of adding an in-line virus filtration step (VF). All three steps were linked sequentially and operated as one continuous process using an ÄKTA FPLC equipped with two pumps and a system of valves and bypasses that allowed the components to be engaged at different stages of the process. The AEX column was operated in a weak partitioning (WP) mode enabled by a precise in-line titration of Protein A effluent. In order to avoid complex control schemes and facilitate validation, quality and robustness were built into the system through selection of buffers based on thermodynamic and empirical models. The tandem system utilized the simplest possible combination of valves, pumps, controls, and automation, so that it could easily be implemented in a clinical or commercial production facility. Linking the purification steps in a tandem process is expected to generate savings in time and production costs and also reduce the size of quality systems due to reduced documentation requirements, microbial sampling, and elimination of hold time validation. Copyright © 2013 Wiley Periodicals, Inc.

  4. The role of polymer nanolayer architecture on the separation performance of anion-exchange membrane adsorbers: I. Protein separations.

    Science.gov (United States)

    Bhut, Bharat V; Weaver, Justin; Carter, Andrew R; Wickramasinghe, S Ranil; Husson, Scott M

    2011-11-01

    This contribution describes the preparation of strong anion-exchange membranes with higher protein binding capacities than the best commercial resins. Quaternary amine (Q-type) anion-exchange membranes were prepared by grafting polyelectrolyte nanolayers from the surfaces of macroporous membrane supports. A focus of this study was to better understand the role of polymer nanolayer architecture on protein binding. Membranes were prepared with different polymer chain graft densities using a newly developed surface-initiated polymerization protocol designed to provide uniform and variable chain spacing. Bovine serum albumin and immunoglobulin G were used to measure binding capacities of proteins with different size. Dynamic binding capacities of IgG were measured to evaluate the impact of polymer chain density on the accessibility of large size protein to binding sites within the polyelectrolyte nanolayer under flow conditions. The dynamic binding capacity of IgG increased nearly linearly with increasing polymer chain density, which suggests that the spacing between polymer chains is sufficient for IgG to access binding sites all along the grafted polymer chains. Furthermore, the high dynamic binding capacity of IgG (>130 mg/mL) was independent of linear flow velocity, which suggests that the mass transfer of IgG molecules to the binding sites occurs primarily via convection. Overall, this research provides clear evidence that the dynamic binding capacities of large biologics can be higher for well-designed macroporous membrane adsorbers than commercial membrane or resin ion-exchange products. Specifically, using controlled polymerization leads to anion-exchange membrane adsorbers with high binding capacities that are independent of flow rate, enabling high throughput. Results of this work should help to accelerate the broader implementation of membrane adsorbers in bioprocess purification steps. Copyright © 2011 Wiley Periodicals, Inc.

  5. Anion-exchange resin-based desulfurization process. Quarterly technical progress report, October 1, 1991--December 31, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, A.C.; Strevel, S.D.

    1991-12-31

    The University of Tennessee Space Institute (UTSI) has a Department of Energy grant to further develop the Institute`s anion-exchange resin-based flue gas, desulfurization concept. The developmental program proposed includes screening of commercially available resins to select three candidate resins for further study. These three resins will undergo a series of experiments designed to test the resins` performance under different process conditions (including the use of spent MHD seed material). The best of these resins will be used in optimizing the regeneration step and in testing the effects of performance enhancers. The process schematic developed from the results will be used to estimate the related economics.

  6. Dynamic separation of Szilard-Chalmers reaction products applied to the trioxalatochromium ion adsorbed on anionic exchange resin

    International Nuclear Information System (INIS)

    Silva, J.B.S.

    1979-01-01

    A method of dynamic elution of recoiled 51 Cr +3 , formed by the Szilard-Chalmers reaction during the irradiation of trioxalatochromium ion adsorbed on anionic exchange resin is presented. The influence of some factors on the separation yield of chromium-51, such as: composition, concentration and flow rate of eluent, mesh size of the resin and irradiation time are studied. The results are compardd with those obtained by the static method, in which the recoiled atom is separated from the target after irradiation. Because of the high separation yield of chromium-51, the method of dynamic separation is proposed for routine production of this elemnt, with high specific activities. (author) [pt

  7. Study of plutonium IV elution from macromolecular anion exchange resin by 0.5 M nitric acid

    International Nuclear Information System (INIS)

    Nadkarni, M.N.; Mayankutty, P.C.; Pillai, N.S.; Shinde, S.S.

    1976-01-01

    Preliminary studies indicated that macroreticular resins possess more or less the same capacities and absorption characteristics for thorium, uranium and plutonium from nitric acid solutions as the conventional resins. Detailed studies were, then, conducted. It was found that Pu(IV) can be loaded on the macroreticular anion exchange resin, Amberlyst A-26 from 7.2 M nitric acid in much the same way as Dowex 1x4. It was also observed that the elution of Pu(IV) from Amberlyst A-26 by 0.5 M nitric acid is much more rapid and quantitative than from Dowex 1x4. (author)

  8. High-performance liquid chromatography separation of cis-trans anthocyanin isomers from wild Lycium ruthenicum Murr. employing a mixed-mode reversed-phase/strong anion-exchange stationary phase.

    Science.gov (United States)

    Jin, Hongli; Liu, Yanfang; Guo, Zhimou; Yang, Fan; Wang, Jixia; Li, Xiaolong; Peng, Xiaojun; Liang, Xinmiao

    2015-01-21

    The cis-trans isomerism is a common phenomenon for acylated anthocyanins. Nevertheless, few studies reported effective methods for the preparation of isomeric anthocyanins from natural products. In this work, a high-performance liquid chromatography (HPLC) method was developed to efficiently purify anthocyanin isomers from Lycium ruthenicum Murr. based on a mixed-mode reversed-phase/strong anion-exchange column (named XCharge C8SAX). Four commercially available columns were evaluated with a pair of isomeric anthocyanins, and the results demonstrated that the XCharge C8SAX column exhibited improved selectivity and column efficiency for the isomers. The chromatographic parameters, including pH, organic content, and ionic strength, were investigated. Optimal separation quality for the anthocyanin isomers was achieved on the XCharge C8SAX column. Six pure anthocyanins, including two pairs of cis-trans isomeric anthocyanins with one new anthocyanin, were purified from L. ruthenicum and identified. All of the results indicated that this method is an effective way to separate anthocyanins, especially for cis-trans isomers.

  9. Comparing and Optimizing Nitrate Adsorption from Aqueous Solution Using Fe/Pt Bimetallic Nanoparticles and Anion Exchange Resins

    International Nuclear Information System (INIS)

    Daud, M.; Khan, Z.; Ashgar, A.; Danish, M. I.; Qazi, I. A.

    2015-01-01

    This research work was carried out for the removal of nitrate from raw water for a drinking water supply. Nitrate is a widespread ground water contaminant. Methodology employed in this study included adsorption on metal based nanoparticles and ion exchange using anionic resins. Fe/Pt bimetallic nanoparticles were prepared in the laboratory, by the reduction of their respective salts using sodium borohydride. Scanning electron microscope, X-ray diffraction, energy dispersive spectrometry, and X-ray florescence techniques were utilized for characterization of bimetallic Fe/Pt nanoparticles. Optimum dose, ph, temperature, and contact time were determined for removal through batch tests, both for metal based nanoparticles and anionic exchange resin. Adsorption data fitted well the Langmuir isotherm and conformed to the pseudo first-order kinetic model. Results indicated 97% reduction in nitrate by 0.25 mg/L of Fe/Pt nanoparticles at ph 7 and 83% reduction in nitrate was observed using 0.50 mg/L anionic exchange resins at ph 4 and contact time of one hour. Overall, Fe/Pt bimetallic nanoparticles demonstrated greater removal efficiency due to the small particle size, extremely large surface area (627 m 2 /g), and high adsorption capacity.

  10. The critical relation between chemical stability of cations and water in anion exchange membrane fuel cells environment

    Science.gov (United States)

    Dekel, Dario R.; Willdorf, Sapir; Ash, Uri; Amar, Michal; Pusara, Srdjan; Dhara, Shubhendu; Srebnik, Simcha; Diesendruck, Charles E.

    2018-01-01

    Anion exchange membrane fuel cells can potentially revolutionize energy storage and delivery; however, their commercial development is hampered by a significant technological impedance: the chemical decomposition of the anion exchange membranes during operation. The hydroxide anions, while transported from the cathode to the anode, attack the positively charged functional groups in the polymer membrane, neutralizing it and suppressing its anion-conducting capability. In recent years, several new quaternary ammonium salts have been proposed to address this challenge, but while they perform well in ex-situ chemical studies, their performance is very limited in real fuel cell studies. Here, we use experimental work, corroborated by molecular dynamics modeling to show that water concentration in the environment of the hydroxide anion, as well as temperature, significantly impact its reactivity. We compare different quaternary ammonium salts that have been previously studied and test their stabilities in the presence of relatively low hydroxide concentration in the presence of different amounts of solvating water molecules, as well as different temperatures. Remarkably, with the right amount of water and at low enough temperatures, even quaternary ammonium salts which are considered "unstable", present significantly improved lifetime.

  11. The influence of plutonium concentration and solution flow rate on the effective capacity of macroporous anion exchange resin

    International Nuclear Information System (INIS)

    Marsh, S.F.; Gallegos, T.D.

    1987-07-01

    The principal aqueous process used to recover and purify plutonium at the Los Alamos Plutonium Facility is anion exchange in nitric acid. Previous studies with gel-type anion exchange resin have shown an inverse relationship between plutonium concentration in the feed solution and the optimum flow rate for this process. Because gel-type resin has been replaced with macroporous resin at Los Alamos, the relationship between plutonium concentration and solution flow rate was reexamined with the selected Lewatit MP-500-FK resin using solutions of plutonium in nitric acid and in nitric acid with high levels of added nitrate salts. Our results with this resin differ significantly from previous data obtained with gel-type resin. Flow-rate variation from 10 to 80 liters per hour had essentially no effect on the measured quantities of plutonium sorbed by the macroporous resin. However, the effect of plutonium concentration in the feed solutions was pronounced, as feed solutions that contained the highest concentrations of plutonium also produced the highest resin loadings. The most notable effect of high concentrations of dissolved nitrate salts in these solutions was an increased resin capacity for plutonium at low flow rates. 16 refs., 7 figs., 2 tabs

  12. Degradation of Imidazolium- and Quaternary Ammonium-Functionalized Poly(fluorenyl ether ketone sulfone) Anion Exchange Membranes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, DY; Hickner, MA

    2012-11-01

    Imidazolium and quaternary ammonium-functionalized poly(fluorenyl ether ketone sulfone)s were synthesized successfully with the same degree of cationic functionalization and identical polymer backbones for a comparative study of anion exchange membranes (AEMs) for solid-state alkaline membrane fuel cells (AMFCs). Both anion exchange membranes were synthesized using a new methyl-containing monomer that avoided the use of toxic chloromethylation reagents. The polymer chemical structures were confirmed by H-1 NMR and FTIR. The derived AEMs were fully characterized by water uptake, anion conductivity, stability under aqueous basic conditions, and thermal stability. Interestingly, both the cationic groups and the polymer backbone were found to be degraded in 1 M NaOH solution at 60 degrees C over 48 h as measured by changes of ion exchange capacity and intrinsic viscosity. Imidazolium-functionalized poly(fluorenyl ether ketone sulfone)s had similar aqueous alkaline stability to quaternary ammonium-functionalized materials at 60 degrees C but much lower stability at 80 degrees C. This work demonstrates that quaternary ammonium and imidazolium cationic groups are not stable on poly(arylene ether sulfone) backbones under relatively mild conditions. Additionally, the poly(arylene ether sulfone) backbone, which is one of the most common polymers used in ion exchange membrane applications, is not stable in the types of molecular configurations analyzed.

  13. Detection of Reactive Oxygen Species in Anion Exchange Membrane Fuel Cells using In Situ Fluorescence Spectroscopy.

    Science.gov (United States)

    Zhang, Yunzhu; Parrondo, Javier; Sankarasubramanian, Shrihari; Ramani, Vijay

    2017-08-10

    The objectives of this study were: 1) to confirm superoxide anion radical (O 2 .- ) formation, and 2) to monitor in real time the rate of O 2 .- generation in an operating anion exchange membrane (AEM) fuel cell using in situ fluorescence spectroscopy. 1,3-Diphenlisobenzofuran (DPBF) was used as the fluorescent molecular probe owing to its selectivity and sensitivity toward O 2 .- in alkaline media. The activation energy for the in situ generation of O 2 .- during AEM fuel cell operation was estimated to be 18.3 kJ mol -1 . The rate of in situ generation of O 2 .- correlated well with the experimentally measured loss in AEM ion-exchange capacity and ionic conductivity attributable to oxidative degradation. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The k{sub 0}-INAA method for the determination of the anion-exchange capacity of propylpyridium silicas

    Energy Technology Data Exchange (ETDEWEB)

    Auler, Lucia M.L.A.; Menezes, Maria Angela de B.C.; Amaral, Angela Maria [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)]. E-mail: aulerlm@cdtn.br; Silva, Cesar R.; Collins, Kenneth E.; Collins, Carol [Universidade Estadual de Campinas, SP (Brazil). Inst. de Quimica. Lab. de Cromatografia Liquida (LABCROM)]. E-mail: chc@iqm.unicamp.br

    2005-07-01

    The present work describes the k{sub 0}-INAA method as an alternative for determination of the ion-exchange capacity of a propyl pyridinium modified silica, which has been recently employed as stationary phase for anion -exchange chromatography. The exchange capacity of the modified silicas was investigated by determining its exchangeable chloride content with k{sub 0}-Instrumental Neutron Activation Analyses. Irradiation experiments were performed in the reactor TRIGA Mark I IPR-R1 located at CDTN/CNEN (Nuclear Technology Development Center / Nuclear Energy National Commission). The results showed that the exchangeable chloride concentration was successfully determined by this analytical method instead of the conventional potentiometric determination with silver nitrate titrimetry. (author)

  15. High-throughput investigation of single and binary protein adsorption isotherms in anion exchange chromatography employing multivariate analysis.

    Science.gov (United States)

    Field, Nicholas; Konstantinidis, Spyridon; Velayudhan, Ajoy

    2017-08-11

    The combination of multi-well plates and automated liquid handling is well suited to the rapid measurement of the adsorption isotherms of proteins. Here, single and binary adsorption isotherms are reported for BSA, ovalbumin and conalbumin on a strong anion exchanger over a range of pH and salt levels. The impact of the main experimental factors at play on the accuracy and precision of the adsorbed protein concentrations is quantified theoretically and experimentally. In addition to the standard measurement of liquid concentrations before and after adsorption, the amounts eluted from the wells are measured directly. This additional measurement corroborates the calculation based on liquid concentration data, and improves precision especially under conditions of weak or moderate interaction strength. The traditional measurement of multicomponent isotherms is limited by the speed of HPLC analysis; this analytical bottleneck is alleviated by careful multivariate analysis of UV spectra. Copyright © 2017. Published by Elsevier B.V.

  16. Spontaneous formation of wurzite-CdS/zinc blende-CdTe heterodimers through a partial anion exchange reaction.

    Science.gov (United States)

    Saruyama, Masaki; So, Yeong-Gi; Kimoto, Koji; Taguchi, Seiji; Kanemitsu, Yoshihiko; Teranishi, Toshiharu

    2011-11-09

    Ion exchange of ionic semiconductor nanoparticles (NPs) is a facile method for the synthesis of type-II semiconductor heterostructured NPs with staggered alignment of band edges for photoelectric applications. Through consideration of the crystallographic orientation and strain at the heterointerface, well-designed heterostructures can be constructed through ion exchange reactions. Here we report the selective synthesis of anisotropically phase-segregated cadmium sulfide (CdS)/ cadmium telluride (CdTe) heterodimers via a novel anion exchange reaction of CdS NPs with an organic telluride precursor. The wurtzite-CdS/zinc blende-CdTe heterodimers in this study resulted from spontaneous phase segregation induced by the differences in the crystal structures of the two phases, accompanying a centrosymmetry breaking of the spherical CdS NPs. The CdS/CdTe heterodimers exhibited photoinduced spatial charge separation because of their staggered band-edge alignment.

  17. Anion exchange removal of Al3+ from Li+-Al3+ aqueous solution (originating from lithium recovery from brine

    Directory of Open Access Journals (Sweden)

    Anissa Somrani

    2014-06-01

    Full Text Available The purpose of this study is to separate aluminum(III ion from an aqueous solution containing Li+ at 25°C. Al3+ was transferred into [Al(C2O43]3- by means of complexation and removed by an anion exchange resin. This resin was anionic type Amberlite IRA 402 regenerated by sodium chloride. Hence, a theoretical study based on speciation diagrams was carried out to determine the best pH domain for separation. The complexation of aluminum ions by ammonium oxalate was studied. The motar ratio of Ox/Al and pH was investigated. Optimum values of these factors were found to be 3 and 4 respectively. In this case, the remaining lithium is 98.5%.

  18. Inhibitors of pendrin anion exchange identified in a small molecule screen increase airway surface liquid volume in cystic fibrosis.

    Science.gov (United States)

    Haggie, Peter M; Phuan, Puay-Wah; Tan, Joseph-Anthony; Zlock, Lorna; Finkbeiner, Walter E; Verkman, A S

    2016-06-01

    Pendrin (SLC26A4) is a Cl(-)/anion exchanger expressed in the epithelium of inflamed airways where it is thought to facilitate Cl(-) absorption and HCO3 (-) secretion. Studies using pendrin knockout mice and airway epithelial cells from hearing-impaired subjects with pendrin loss of function suggest involvement of pendrin in inflammatory lung diseases, including cystic fibrosis (CF), perhaps by regulation of airway surface liquid (ASL) volume. Here we identified small-molecule pendrin inhibitors and demonstrated their efficacy in increasing ASL volume. A cell-based, functional high-throughput screen of ∼36,000 synthetic small molecules produced 3 chemical classes of inhibitors of human pendrin. After structure-activity studies, tetrahydropyrazolopyridine and pyrazolothiophenesulfonamide compounds reversibly inhibited pendrin-facilitated Cl(-) exchange with SCN(-), I(-), NO3 (-), and HCO3 (-) with drug concentration causing 50% inhibition down to ∼2.5 μM. In well-differentiated primary cultures of human airway epithelial cells from non-CF and CF subjects, treatment with IL-13, which causes inflammation with strong pendrin up-regulation, strongly increased Cl(-)/HCO3 (-) exchange and the increase was blocked by pendrin inhibition. Pendrin inhibition significantly increased ASL depth (by ∼8 μm) in IL-13-treated non-CF and CF cells but not in untreated cells. These studies implicate the involvement of pendrin-facilitated Cl(-)/HCO3 (-) in the regulation of ASL volume and suggest the utility of pendrin inhibitors in inflammatory lung diseases, including CF.-Haggie, P. M., Phuan, P.-W., Tan, J.-A., Zlock, L., Finkbeiner, W. E., Verkman, A. S. Inhibitors of pendrin anion exchange identified in a small molecule screen increase airway surface liquid volume in cystic fibrosis. © FASEB.

  19. Characteristics of competitive uptake between Microcystin-LR and natural organic matter (NOM) fractions using strongly basic anion exchange resins.

    Science.gov (United States)

    Dixit, Fuhar; Barbeau, Benoit; Mohseni, Madjid

    2018-03-29

    Microcystins are the most commonly occurring cyanotoxins, and have been extensively studied across the globe. In the present study, a strongly basic anion exchange resin was employed to investigate the removal of Microcystin-LR (MCLR), one of the most toxic microcystin variants. Factors influencing the uptake behavior included the MCLR and resin concentrations, resin dosage, and natural organic matter (NOM) characteristics, specifically, the charge density and molecular weight distribution of source water NOM. Equivalent background concentration (EBC) was employed to evaluate the competitive uptake between NOM and MCLR. The experimental data were compared with different mathematical and physical models and pore diffusion was determined as the rate-limiting step. The resin dose/solute concentration ratio played a key role in the MCLR uptake process and MCLR removal was attributed primarily to electrostatic attractions. Charge density and molecular weight distribution of the background NOM fractions played a major role in MCLR removal at lower resin dosages (200 mg/L ∼ 1 mL/L and below), where a competitive uptake was observed due to the limited exchange sites. Further, evidences of pore blockage and site reduction were also observed in the presence of humics and larger molecular weight organic fractions, where a four-fold reduction in the MCLR uptake was observed. Comparable results were obtained for laboratory studies on synthetic laboratory water and surface water under similar conditions. Given their excellent performance and low cost, anion exchange resins are expected to present promising potentials for applications involving the removal of removal of algal toxins and NOM from surface waters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Removal of transmissible spongiform encephalopathy prion from large volumes of cell culture media supplemented with fetal bovine serum by using hollow fiber anion-exchange membrane chromatography.

    Science.gov (United States)

    Chou, Ming Li; Bailey, Andy; Avory, Tiffany; Tanimoto, Junji; Burnouf, Thierry

    2015-01-01

    Cases of variant Creutzfeldt-Jakob disease in people who had consumed contaminated meat products from cattle with bovine spongiform encephalopathy emphasize the need for measures aimed at preventing the transmission of the pathogenic prion protein (PrPSc) from materials derived from cattle. Highly stringent scrutiny is required for fetal bovine serum (FBS), a growth-medium supplement used in the production of parenteral vaccines and therapeutic recombinant proteins and in the ex vivo expansion of stem cells for transplantation. One such approach is the implementation of manufacturing steps dedicated to removing PrPSc from materials containing FBS. We evaluated the use of the QyuSpeed D (QSD) adsorbent hollow-fiber anion-exchange chromatographic column (Asahi Kasei Medical, Tokyo, Japan) for the removal of PrPSc from cell culture media supplemented with FBS. We first established that QSD filtration had no adverse effect on the chemical composition of various types of culture media supplemented with 10% FBS or the growth and viability characteristics of human embryonic kidney (HEK293) cells, baby hamster kidney (BHK-21) cells, African green monkey kidney (Vero) cells, and Chinese hamster ovary (CHO-k1) cells propagated in the various culture-medium filtrates. We used a 0.6-mL QSD column for removing PrPSc from up to 1000 mL of Dulbecco's modified Eagle's medium containing 10% FBS previously spiked with the 263K strain of hamster-adapted scrapie. The Western blot analysis, validated alongside an infectivity assay, revealed that the level of PrPSc in the initial 200mL flow-through was reduced by 2.5 to > 3 log10, compared with that of the starting material. These results indicate that QSD filtration removes PrPSc from cell culture media containing 10% FBS, and demonstrate the ease with which QSD filtration can be implemented in at industrial-scale to improve the safety of vaccines, therapeutic recombinant proteins, and ex vivo expanded stem cells produced using growth

  1. Removal of transmissible spongiform encephalopathy prion from large volumes of cell culture media supplemented with fetal bovine serum by using hollow fiber anion-exchange membrane chromatography.

    Directory of Open Access Journals (Sweden)

    Ming Li Chou

    Full Text Available Cases of variant Creutzfeldt-Jakob disease in people who had consumed contaminated meat products from cattle with bovine spongiform encephalopathy emphasize the need for measures aimed at preventing the transmission of the pathogenic prion protein (PrPSc from materials derived from cattle. Highly stringent scrutiny is required for fetal bovine serum (FBS, a growth-medium supplement used in the production of parenteral vaccines and therapeutic recombinant proteins and in the ex vivo expansion of stem cells for transplantation. One such approach is the implementation of manufacturing steps dedicated to removing PrPSc from materials containing FBS. We evaluated the use of the QyuSpeed D (QSD adsorbent hollow-fiber anion-exchange chromatographic column (Asahi Kasei Medical, Tokyo, Japan for the removal of PrPSc from cell culture media supplemented with FBS. We first established that QSD filtration had no adverse effect on the chemical composition of various types of culture media supplemented with 10% FBS or the growth and viability characteristics of human embryonic kidney (HEK293 cells, baby hamster kidney (BHK-21 cells, African green monkey kidney (Vero cells, and Chinese hamster ovary (CHO-k1 cells propagated in the various culture-medium filtrates. We used a 0.6-mL QSD column for removing PrPSc from up to 1000 mL of Dulbecco's modified Eagle's medium containing 10% FBS previously spiked with the 263K strain of hamster-adapted scrapie. The Western blot analysis, validated alongside an infectivity assay, revealed that the level of PrPSc in the initial 200mL flow-through was reduced by 2.5 to > 3 log10, compared with that of the starting material. These results indicate that QSD filtration removes PrPSc from cell culture media containing 10% FBS, and demonstrate the ease with which QSD filtration can be implemented in at industrial-scale to improve the safety of vaccines, therapeutic recombinant proteins, and ex vivo expanded stem cells produced

  2. Use of strong anion exchange resins for the removal of perfluoroalkylated substances from contaminated drinking water in batch and continuous pilot plants.

    Science.gov (United States)

    Zaggia, Alessandro; Conte, Lino; Falletti, Luigi; Fant, Massimo; Chiorboli, Andrea

    2016-03-15

    In recent years abnormally high levels of perfluoroalkylated substances (PFAS) have been detected both in surface and underground water sampled in an area covering approximately 150 square kilometers in the Veneto region (Italy) indicating the presence of a pollution point source (fluorochemicals production plant). Adsorption on granular activated carbon is an emergency measure which is poorly effective requiring frequent replacement. This work focuses on the application of three strong anion exchange resins (Purolite® A520E, A600E and A532E) for the removal of traces of PFOA, PFOS, PFBA and PFBS (concentration of hundreds of ng L(-1)) from drinking water. This technology is attractive for the possibility of reusing resins after an in-situ regeneration step. A strong relationship between the hydrophobicity of the exchange functional group of the resin and its capacity in removing PFAS exists. A600E (non hydrophobic) and A520E (fairly hydrophobic) show a reduced sorption capacity compared to A532E (highly hydrophobic). While A600E and A520E can be regenerated with solvent-less dilute solutions of non-toxic NH4Cl and NH4OH, A532E requires concentrated solutions of methanol or ethanol and 1% NH4Cl and for the sake of this work it was regarded as non-regenerable. The volume of regeneration effluents requiring incineration can be efficiently reduced by more than 96.5% by using reverse osmosis coupled with under-vacuum evaporation. Transmission electron analysis on saturated resins showed that large molecular macro-aggregates of PFAS can form in the intraparticle pores of resin indicating that ion exchange is not the only mechanism involved in PFAS removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Complexation or uranyl ion. II. Complexation of uranyl ion in the VP-IAp anion exchanger phase during sorption from carbonate media

    International Nuclear Information System (INIS)

    Stupin, N.P.; Kakhaeva, T.V.; Buskina, I.A.; Rodionov, V.V.; Vodolazov, L.I.; Zhukova, N.G.

    1987-01-01

    The complicated process of increased uranium sorption from carbonate medium by the strongly basic anion exchanger VP-1Ap after additional treatment with alkaline solution was studied by IR spectroscopy. The process is related to the formation of certain complex forms of uranyl, differing in degree of polymerization, in which polynuclear forms predominate

  4. Separation of plutonium on the anion exchanger BIO-RAD 1-X2 and its application to radiochemical analysis

    International Nuclear Information System (INIS)

    Bajo, S.; Gann, C.; Eikenberg, J.; Wyer, L.; Beer, H.; Ruethi, M.; Jaeggi, M.; Zumsteg, I.

    2007-12-01

    The element Pu (Z = 94) is a member of the actinide series of the elements (Z = 89 -103). The actinides have similar chemical properties and are also similar to the lanthanides (Z = 57 -71). Sixteen isotopes of Pu have been synthesized, all of which are radioactive. The Pu present in the environment originates from the atmospheric nuclear tests from 1950 to 1963, which produced the so-called 'global fallout'. As a result, 6.5 · 10 15 Bq 239 Pu (2.8 tons), 4.4 · 10 15 Bq 240 Pu (0.52 tons), and 3.7 · 10 4 Bq 241 Pu (0.04 tons) were dispersed over the world. A contribution also to the global fallout was the ignition of the satellite SWAP 9A in the atmosphere in 1964, equipped with a battery powered by 6.3 · 10 14 Bq (1 kg) of 238 Pu. In addition to these sources, nuclear reactors, reprocessing plants and radioactive waste facilities may contribute with their emissions to increase locally the Pu concentration in their environment. In the PSI laboratory, we are confronted with the determination of traces of 238 Pu, 239 Pu and 240 Pu in environmental and biological materials. Because of the low quantity of Pu in the analyzed samples, which is usually below 100 mBq, it is mandatory to separate the Pu from all other accompanying elements. The separated Pu is then measured by alpha spectrometry. In this work, the anion exchanger BIO-RAD AG 1 is extensively used for the separation of Pu from different matrices. This exchanger is superior when only Pu is determined in the sample. In addition, it is also very suitable when other actinides, such as Am and Cm, are also determined. No preconcentration step is necessary for the Pu separation. The resins introduced by the company Eichrom Industries in the 90's, which allow the separation of the actinides from the major environmental elements and from each other, requires relatively small volumes of sample solution. This report describes the extensive utilization of the classical anion exchanger BIO-RAD 1-X2 in 8 molar nitric

  5. Selective isolation of β-glucan from corn pericarp hemicelluloses by affinity chromatography on cellulose column.

    OpenAIRE

    Yoshida, Tomoki; Honda, Yoichi; Tsujimoto, Takashi; Uyama, Hiroshi; Azuma, Jun-ichi

    2014-01-01

    A combination of anion-exchange chromatography and affinity chromatography on a cellulose column was found to be effective for the isolation of β-(1, 3;1, 4)-glucan (BG) from corn pericarp hemicelluloses (CPHs). CPHs containing 6.6% BG were extracted from corn pericarp with 6M urea-2 wt% NaOH solution and initially fractionated into neutral and acidic parts by anion exchange chromatography to remove acidic arabinoxylan consisting of arabinose (35.6%) and xylose (50.9%). The neutral fraction (...

  6. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  7. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  8. Analysis of human milk oligosaccharides using high-performance anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Lie, Aleksander; Pedersen, Lars Haastrup

    Human Milk Oligosaccharides (HMOs) are composed of 5 different monosaccharides: D-glucose, D-galactose, L-fucose, N-acetylneuraminic acid and N-acetylglucosamine. Approximately 200 unique structures have been identified, ranging in the degree of polymerization from 3 to 22. The diversity among......-based molecules necessitates analysis methods that can provide separation and quantification of the common structural constituents mentioned, as well as the disaccharide lactose (Galβ1-4Glc) and oligosaccharides such as lacto-N-triose II (GlcNAcβ1-3Galβ1-4Glc), lacto-N-tetraose (Galβ1-3GlcNAcβ1-3Galβ1-4Glc......) and lacto-N-neotetraose (Galβ1-4GlcNAcβ1-3Galβ1-4Glc), among others. High-performance anion-exchange chromatography (HPAE) with pulsed amperometric detection (PAD) is an analysis method highly suited for carbohydrates. HPAE with alkaline eluents results in retention of neutral carbohydrates depending...

  9. Quantification of genetically modified soya using strong anion exchange chromatography and time-of-flight mass spectrometry.

    Science.gov (United States)

    Chang, Po-Chih; Reddy, P Muralidhar; Ho, Yen-Peng

    2014-09-01

    Stable-isotope dimethyl labeling was applied to the quantification of genetically modified (GM) soya. The herbicide-resistant gene-related protein 5-enolpyruvylshikimate-3-phosphate synthase (CP4 EPSPS) was labeled using a dimethyl labeling reagent, formaldehyde-H2 or -D2. The identification and quantification of CP4 EPSPS was performed using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The CP4 EPSPS protein was separated from high abundance proteins using strong anion exchange chromatography and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Then, the tryptic peptides from the samples and reference were labeled with formaldehyde-H2 and formaldehyde-D2, respectively. The two labeled pools were mixed and analyzed using MALDI-MS. The data showed a good correlation between the peak ratio of the H- and D-labeled peptides and the GM soya percentages at 0.5, 1, 3, and 5 %, with R (2) of 0.99. The labeling reagents are readily available. The labeling experiments and the detection procedures are simple. The approach is useful for the quantification of GM soya at a level as low as 0.5 %.

  10. Dissolved organic matter removal using magnetic anion exchange resin treatment on biological effluent of textile dyeing wastewater.

    Science.gov (United States)

    Fan, Jun; Li, Haibo; Shuang, Chendong; Li, Wentao; Li, Aimin

    2014-08-01

    This study investigated the removal of dissolved organic matter (DOM) from real dyeing bio-treatment effluents (DBEs) with the use of a novel magnetic anion exchange resin (NDMP). DOMs in two typical DBEs were fractionized using DAX-8/XAD-4 resin and ultrafiltration membranes. The hydrophilic fractions and the low molecular weight (MW) (50%) of DOMs for the two effluents. The hydrophilic and low MW fractions of both effluents were the greatest contributors of specific UV254 absorbance (SUVA254), and the SUVA254 of DOM fractions decreased with hydrophobicity and MW. Two DBEs exhibited acute and chronic biotoxicities. Both acute and chronic toxicities of DOM fractions increased linearly with the increase of SUVA254 value. Kinetics of dissolved organic carbon (DOC) removal via NDMP treatment was performed by comparing it with that of particle active carbon (PAC). Results indicated that the removal of DOC from DBEs via NDMP was 60%, whereas DOC removals by PAC were lower than 15%. Acidic organics could be significantly removed with the use of NDMP. DOM with large MW in DBE could be removed significantly by using the same means. Removal efficiency of NDMP for DOM decreased with the decrease of MW. Compared with PAC, NDMP could significantly reduce the acute and chronic bio-toxicities of DBEs. NaCl/NaOH mixture regenerants, with selected concentrations of 10% NaCl (m/m)/1% NaOH (m/m), could improve desorption efficiency. Copyright © 2014. Published by Elsevier B.V.

  11. Kinetics and mechanism of the sorption of some aromatic amines onto amberlite IRA-904 anion-exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Zaki, A.B.; El-Sheikh, M.Y.; Evans, J.; El-Safty, S.A.

    2000-01-01

    The kinetics of the sorption of aromatic amines such as o-aminophenol (o-AP), o-phenylenediamine (o-PDA), and p-phenylenediamine (p-PDA) onto Amberlite anion-exchange resin in chloride form was investigated in batch experiments spectrophotometrically at different temperatures. The sorption rate is zero order in all amines sorbed, increasing directly in the order: p-PDA < o-PDA < o-AP, which corresponds to the sequence of the electrostatic contributions to the sorption interactions. The attainments of sorption equilibrium of aromatic amines is seen to be similar. The diffusion coefficients (D) have been calculated by using Fick's equation from the second portions of the sorption/desorption curves; D values ranged from 0.7 to 2.8 x 10{sup {minus}9} cm{sup 2}/s. These results, reflecting the diffusion mechanism, were ascribed to intraparticle diffusion. Arrhenius parameters for the diffusion process and the thermodynamic quantities for the process of equilibrium sorption have been estimated. The effect of a chemical oxidation reaction on intraparticle diffusion was investigated by measuring the intraparticle diffusion of amines during the redox reaction.

  12. Kinetics and Mechanism of the Sorption of Some Aromatic Amines onto Amberlite IRA-904 Anion-Exchange Resin.

    Science.gov (United States)

    Zaki; El-Sheikh; Evans; El-Safty

    2000-01-01

    The kinetics of the sorption of aromatic amines such as o-aminophenol (o-AP), o-phenylenediamine (o-PDA), and p-phenylenediamine (p-PDA) onto Amberlite anion-exchange resin in chloride form was investigated in batch experiments spectrophotometrically at different temperatures. The sorption rate is zero order in all amines sorbed, increasing directly in the order: p-PDA

  13. Study of operating conditions and cell design on the performance of alkaline anion exchange membrane based direct methanol fuel cells

    Science.gov (United States)

    Prakash, G. K. Surya; Krause, Frederick C.; Viva, Federico A.; Narayanan, S. R.; Olah, George A.

    2011-10-01

    Direct methanol fuel cells using an alkaline anion exchange membrane (AAEM) were prepared, studied, and optimized. The effects of fuel composition and electrode materials were investigated. Membrane electrode assemblies fabricated with Tokuyama® AAEM and commercial noble metal catalysts achieved peak power densities between 25 and 168 mW cm-2 depending on the operating temperature, fuel composition, and electrode materials used. Good electrode wettability at the anode was found to be very important for achieving high power densities. The performance of the best AAEM cells was comparable to Nafion®-based cells under similar conditions. Factors limiting the performance of AAEM MEAs were found to be different from those of Nafion® MEAs. Improved electrode kinetics for methanol oxidation in alkaline electrolyte at Pt-Ru are apparent at low current densities. At high current densities, rapid CO2 production converts the hydroxide anions, necessary for methanol oxidation, to bicarbonate and carbonate: consequently, the membrane and interfacial conductivity are drastically reduced. These phenomena necessitate the use of aqueous potassium hydroxide and wettable electrode materials for efficient hydroxide supply to the anode. However, aqueous hydroxide is not needed at the cathode. Compared to AAEM-based fuel cells, methanol fuel cells based on proton-conducting Nafion® retain better performance at high current densities by providing the benefit of carbon dioxide rejection.

  14. Evaluation of ferrocyanide anion exchange resins regarding the uptake of Cs{sup +} ions and their regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Won, Hui Jun; Mooon, Jei Kwon; Jung, Chong Hun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Chung, Won Yang [Kangwon University, Chuncheon (Korea, Republic of)

    2008-10-15

    Ferrocyanide-anion exchange resin was prepared and the prepared ion exchange resins were tested on the ability to uptake Cs{sup +} ion. The prepared ion exchange resins were resin-KCoFC, resin-KNiFC, and resin-KCuFC. The three tested ion exchange resins showed ion exchange selectivity on the Cs{sup +} ion of the surrogate soil decontamination solution, and resin- KCoFC showed the best Cs{sup +} ion uptake capability among the tested ion exchange resins. The ion exchange behaviors were explained well by the modified Dubinin-Polanyi equation. A regeneration feasibility study of the spent ion exchange resins was also performed by the successive application of hydrogen peroxide and hydrazine. The desorption of the Cs{sup +} ion from the ion exchange resin satisfied the electroneutrality condition in the oxidation step; the desorption of the Fe{sup 2+} ion in the reduction step could also be reduced by adding the K{sup +} ion.

  15. Formation of carbon nanosheets via simultaneous activation and catalytic carbonization of macroporous anion-exchange resin for supercapacitors application.

    Science.gov (United States)

    Peng, Hui; Ma, Guofu; Sun, Kanjun; Mu, Jingjing; Zhang, Zhe; Lei, Ziqiang

    2014-12-10

    Two-dimensional mesoporous carbon nanosheets (CNSs) have been prepared via simultaneous activation and catalytic carbonization route using macroporous anion-exchange resin (AER) as carbon precursor and ZnCl2 and FeCl3 as activating agent and catalyst, respectively. The iron catalyst in the skeleton of the AER may lead to carburization to form a sheetlike structure during the carbonization process. The obtained CNSs have a large number of mesopores, a maximum specific surface area of 1764.9 m(2) g(-1), and large pore volume of 1.38 cm(3) g(-1). As an electrode material for supercapacitors application, the CNSs electrode possesses a large specific capacitance of 283 F g(-1) at 0.5 A g(-1) and excellent rate capability (64% retention ratio even at 50 A g(-1)) in 6 mol L(-1) KOH. Furthermore, CNSs symmetric supercapacitor exhibits specific energies of 17.2 W h kg(-1) at a power density of 224 W kg(-1) operated in the voltage range of 0-1.8 V in 0.5 mol L(-1) Na2SO4 aqueous electrolyte, and outstanding cyclability (retains about 96% initial capacitance after 5000 cycles).

  16. Electrocatalytic oxidation of meso-erythritol in anion-exchange membrane alkaline fuel cell on PdAg/CNT catalyst

    Science.gov (United States)

    Benipal, Neeva; Qi, Ji; McSweeney, Ryan F.; Liang, Changhai; Li, Wenzhen

    2018-01-01

    C-C bond cleavage during electrocatalytic oxidation of glycerol and C3+ polyols often occurs and can significantly affect the Faradaic efficiency, fuel utilization, and output power density of a direct polyol fuel cell, although this has not been deeply investigated. With the goal of acquiring new knowledge of C-C bond breaking of polyols, this study examines the electrocatalytic oxidation of a C4 polyol meso-erythritol on carbon nanotube supported Pd-based catalysts (Pd/CNT, PdAg/CNT, and PdAg3/CNT) in an anion-exchange membrane fuel cell (AEMFC). Our results show that PdAg/CNT improves the fuel efficiency of meso-erythritol oxidation by contributing to the C-C bond cleavage of meso-erythritol in C3 and C2 chemicals. Based on the analysis of electro-oxidation products and half-cell cyclic voltammetry (CV) of intermediates, a meso-erythritol electro-oxidation pathway has been proposed to demonstrate that Ag is likely to assist Pd to promote the cleavage of C-C bonds of meso-erythritol.

  17. Anion-exchange resin-based desulfurization process. Annual technical progress report, October 1, 1991--September 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, A.C.; Strevel, S.D.; Dharmapurikar, R.

    1992-12-31

    Under the current grant, the University of Tennessee Space Institute (UTSI) will carry out the bench scale evaluation and further development of the anion-exchange resin-based desulfurization concept to desulfurize alkali metal sulfates. This concept has been developed and patented by UTSI under US Patent No. 4,917,874. The developmental program proposed under this DOE grant includes screening of commercially available resins to select three candidate resins for further study. These three resins will undergo a series of experiments designed to test the resins` performance under different process conditions (including the use of spent MHD seed material). The best of these resins will be used in optimizing the regeneration step and in testing the effects of performance enhancers. The process schematic developed from the results will be used to estimate the related economics. During this reporting period, October 1, 1991 to September 30, 1992, analysis of batch mode screening experiments was completed to select three candidate resins for process variables study in the fixed-bed set-up. This setup was modified and the experiments were carded out to evaluate effects of major process variables. The analysis of fixed-bed experiments is going on and we have also started simple batch mode experiments to identify desirable conditions for resin regeneration step. We have also started simple process engineering type calculations to determine the trade-off between the solution concentration and the resulting evaporation/concentration load.

  18. Method for the direct determination of available carbohydrates in low-carbohydrate products using high-performance anion exchange chromatography.

    Science.gov (United States)

    Ellingson, David; Potts, Brian; Anderson, Phillip; Burkhardt, Greg; Ellefson, Wayne; Sullivan, Darryl; Jacobs, Wesley; Ragan, Robert

    2010-01-01

    An improved method for direct determination of available carbohydrates in low-level products has been developed and validated for a low-carbohydrate soy infant formula. The method involves modification of an existing direct determination method to improve specificity, accuracy, detection levels, and run times through a more extensive enzymatic digestion to capture all available (or potentially available) carbohydrates. The digestion hydrolyzes all common sugars, starch, and starch derivatives down to their monosaccharide components, glucose, fructose, and galactose, which are then quantitated by high-performance anion-exchange chromatography with photodiode array detection. Method validation consisted of specificity testing and 10 days of analyzing various spike levels of mixed sugars, maltodextrin, and corn starch. The overall RSD was 4.0% across all sample types, which contained within-day and day-to-day components of 3.6 and 3.4%, respectively. Overall average recovery was 99.4% (n = 10). Average recovery for individual spiked samples ranged from 94.1 to 106% (n = 10). It is expected that the method could be applied to a variety of low-carbohydrate foods and beverages.

  19. Anion exchange HPLC isolation of high-density lipoprotein (HDL and on-line estimation of proinflammatory HDL.

    Directory of Open Access Journals (Sweden)

    Xiang Ji

    Full Text Available Proinflammatory high-density lipoprotein (p-HDL is a biomarker of cardiovascular disease. Sickle cell disease (SCD is characterized by chronic states of oxidative stress that many consider to play a role in forming p-HDL. To measure p-HDL, apolipoprotein (apo B containing lipoproteins are precipitated. Supernatant HDL is incubated with an oxidant/LDL or an oxidant alone and rates of HDL oxidation monitored with dichlorofluorescein (DCFH. Although apoB precipitation is convenient for isolating HDL, the resulting supernatant matrix likely influences HDL oxidation. To determine effects of supernatants on p-HDL measurements we purified HDL from plasma from SCD subjects by anion exchange (AE chromatography, determined its rate of oxidation relative to supernatant HDL. SCD decreased total cholesterol but not triglycerides or HDL and increased cell-free (cf hemoglobin (Hb and xanthine oxidase (XO. HDL isolated by AE-HPLC had lower p-HDL levels than HDL in supernatants after apoB precipitation. XO+xanthine (X and cf Hb accelerated purified HDL oxidation. Although the plate and AE-HPLC assays both showed p-HDL directly correlated with cf-Hb in SCD plasma, the plate assay yielded p-HDL data that was influenced more by cf-Hb than AE-HPLC generated p-HDL data. The AE-HPLC p-HDL assay reduces the influence of the supernatants and shows that SCD increases p-HDL.

  20. Anion exchange membranes based on terminally crosslinked methyl morpholinium-functionalized poly(arylene ether sulfone)s

    Science.gov (United States)

    Kwon, Sohyun; Rao, Anil H. N.; Kim, Tae-Hyun

    2018-01-01

    Azide-assisted terminal crosslinking of methyl morpholinium-functionalized poly(arylene ether sulfone) block copolymers yields products (xMM-PESs) suitable for use as anion exchange membranes. By combining the advantages of bulky morpholinium conductors and our unique polymer network crosslinked only at the termini of the polymer chains, we can produce AEMs that after the crosslinking show minimal loss in conductivity, yet with dramatically reduced water uptake. Terminal crosslinking also significantly increases the thermal, mechanical and chemical stability levels of the membranes. A high ion conductivity of 73.4 mS cm-1 and low water uptake of 26.1% at 80 °C are obtained for the crosslinked membrane with higher amount of hydrophilic composition, denoted as xMM-PES-1.5-1. In addition, the conductivity of the crosslinked xMM-PES-1.5-1 membrane exceeds that of its non-crosslinked counterpart (denoted as MM-PES-1.5-1) above 60 °C at 95% relative humidity because of its enhanced water retention capacity caused by the terminally-crosslinked structure.

  1. Construction of porous CuCo2S4nanorod arrays via anion exchange for high-performance asymmetric supercapacitor.

    Science.gov (United States)

    Cheng, Siyi; Shi, Tielin; Chen, Chen; Zhong, Yan; Huang, Yuanyuan; Tao, Xiangxu; Li, Junjie; Liao, Guanglan; Tang, Zirong

    2017-07-27

    To push the energy density limit of supercapacitors, proper pseudocapacitive materials with favorable nanostructures are urgently pursued. Ternary transition metal sulfides are promising electrode materials due to the better conductivity and higher electrochemical activity in comparison to the single element sulfides and transition metal oxides. In this work, we have successfully synthesized porous CuCo 2 S 4 nanorod array (NRAs) on carbon textile through a stepwise hydrothermal method, including the growth of the Cu-Co precursor nanowire arrays and subsequent conversion into CuCo 2 S 4 NRAs via anion exchange reaction. The CuCo 2 S 4 NRAs electrode exhibits a greatly enhanced specific capacitance and an outstanding cycling stability. Moreover, an asymmetric supercapacitor using the CuCo 2 S 4 NRAs as positive electrode and activated carbon as negative electrode delivers a high energy density of 56.96 W h kg -1 . Such superior performance demonstrate that the CuCo 2 S 4 NRAs are promising materials for future energy storage applications.

  2. Mitigating arsenic crisis in the developing world: role of robust, reusable and selective hybrid anion exchanger (HAIX).

    Science.gov (United States)

    German, Michael; Seingheng, Hul; SenGupta, Arup K

    2014-08-01

    In trying to address the public health crisis from the lack of potable water, millions of tube wells have been installed across the world. From these tube wells, natural groundwater contamination from arsenic regularly puts at risk the health of over 100 million people in South and Southeast Asia. Although there have been many research projects, awards and publications, appropriate treatment technology has not been matched to ground level realities and water solutions have not scaled to reach millions of people. For thousands of people from Nepal to India to Cambodia, hybrid anion exchange (HAIX) resins have provided arsenic-safe water for up to nine years. Synthesis of HAIX resins has been commercialized and they are now available globally. Robust, reusable and arsenic-selective, HAIX has been in operation in rural communities over numerous cycles of exhaustion-regeneration. All necessary testing and system maintenance is organized by community-level water staff. Removed arsenic is safely stored in a scientifically and environmentally appropriate manner to prevent future hazards to animals or people. Recent installations have shown the profitability of HAIX-based arsenic treatment, with capital payback periods of only two years in ideal locations. With an appropriate implementation model, HAIX-based treatment can rapidly scale and provide arsenic-safe water to at-risk populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Liquid–liquid anion exchange extraction studies of samarium(III from salicylate media using high molecular weight amine

    Directory of Open Access Journals (Sweden)

    Aniruddha M. Mandhare

    2015-07-01

    Full Text Available Liquid–liquid extraction and separation of samarium(III were carried out by using 0.025 mol dm−3 2-octylaminopyridine(2-OAP in xylene at 298 K. The extraction behavior of samarium was studied as a function of pH, weak acid concentration, extractant concentration, diluent, and equilibration time. Samarium was quantitatively extracted at pH 7.5 to 10.0 from 0.01 mol dm−3 sodium salicylate solution with 0.025 mol dm−3 2-OAP. The possible composition of the extracted species in organic phase has been determined by using model of slope analysis method and extraction mechanism was found to proceed via an anion exchange mechanism. The stripping efficiency was found to be quantitative in HNO3, HCl and CH3COOH. The robustness of the procedure was demonstrated by the average recoveries obtained (>99.6% for samarium(III extraction in the presence of several cations and anions which are commonly associated with it. The proposed method facilitates the separation and determination of samarium(III from binary and synthetic mixtures. The various thermodynamic functions like free energy (ΔG, enthalpy (ΔH and entropy (ΔS of extraction mechanism were discussed.

  4. Continuous biodiesel production in a fixed bed reactor packed with anion-exchange resin as heterogeneous catalyst.

    Science.gov (United States)

    Ren, Yanbiao; He, Benqiao; Yan, Feng; Wang, Hong; Cheng, Yu; Lin, Ligang; Feng, Yaohui; Li, Jianxin

    2012-06-01

    A continuous biodiesel production from the transesterification of soybean oil with methanol was investigated in a fixed bed reactor packed with D261 anion-exchange resin as a heterogeneous catalyst. The conversion to biodiesel achieved 95.2% within a residence time 56 min under the conditions: reaction temperature of 323.15K, n-hexane/soybean oil weight rate of 0.5, methanol/soybean oil molar ratio of 9:1 and feed flow rate of 1.2 ml/min. The resin can be regenerated in-situ and restored to the original activity to achieve continuous production after the resin deactivation. The product obtained was mainly composed of methyl esters. No glycerol in the product was detected due to the resin adsorbing glycerol in the fixed bed, which solved the issue of glycerol separation from biodiesel. It is believed that the fixed bed reactor with D261 has a potential commercial application in the transesterification of triglyceride. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Mimicking the cell membrane: bio-inspired simultaneous functions with monovalent anion selectivity and antifouling properties of anion exchange membrane

    Science.gov (United States)

    Zhao, Yan; Liu, Huimin; Tang, Kaini; Jin, Yali; Pan, Jiefeng; der Bruggen, Bart Van; Shen, Jiangnan; Gao, Congjie

    2016-11-01

    A new bio-inspired method was applied in this study to simultaneously improve the monovalent anion selectivity and antifouling properties of anion exchange membranes (AEMs). Three-layer architecture was developed by deposition of polydopamine (PDA) and electro-deposition of N-O-sulfonic acid benzyl chitosan (NSBC). The innermost and outermost layers were PDA with different deposition time. The middle layer was prepared by NSBC. Fourier transform infrared spectroscopy and scanning electron microscopy confirmed that PDA and NSBC were successfully modified on the surfaces of AEMs. The contact angle of the membranes indicated an improved hydrophilicity of the modified membranes. A series of electrodialysis experiments in which Cl-/SO42- separation was studied, demonstrating the monovalent anion selectivity of the samples. The Cl-/SO42- permselectivity of the modified membranes can reach up to 2.20, higher than that of the commercial membrane (only 0.78) during 90 minutes in electrodialysis (ED). The increase value of the resistance of the membranes was also measured to evaluate the antifouling properties. Sodium dodecyl benzene sulfonate (SDBS) was used as the fouling material in the ED process and the membrane area resistance of modified membrane increase value of was only 0.08 Ωcm2 30 minutes later.

  6. Determination of zearalenone content in cereals and feedstuffs by immunoaffinity column coupled with liquid chromatography.

    Science.gov (United States)

    Fazekas, B; Tar, A

    2001-01-01

    The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.

  7. Evaluating the effect of in-process material on the binding mechanisms of surrogate viral particles to a multi-modal anion exchange resin.

    Science.gov (United States)

    Brown, Matthew R; Burnham, Michael S; Johnson, Sarah A; Lute, Scott C; Brorson, Kurt A; Roush, David J

    2018-02-10

    Bacteriophage binding mechanisms to multi-modal anion exchange resin may include both anion exchange and hydrophobic interactions, or the mechanism can be dominated by a single moiety. However, previous studies have reported binding mechanisms defined for simple solutions containing only buffer and a surrogate viral spike (i.e. bacteriophage ΦX174, PR772, and PP7). We employed phage spiked in-process monoclonal antibody (mAb) pools to model binding under bioprocessing conditions. These experiments allow the individual contributions of the mAb, in-process impurities, and buffer composition on mechanistic removal of phages to be studied. PP7 and PR772 use synergetic binding by the positively charged quaternary amine and the hydrophobic aromatic phenyl group to bind multi-modal resin. ΦX174's binding mechanism remains inconclusive due to operating conditions. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Radioanalytical determination of 239+240Pu and 241Am in bioassay samples by anion exchange and extraction chromatography: Preliminary considerations about the two methods

    Science.gov (United States)

    Ridone, S.; Arginelli, D.; Berton, G.; Bortoluzzi, S.; Canuto, G.; Montalto, M.; Nocente, M.; Vegro, M.

    2006-01-01

    During the radiation protection surveillance of exposed workers samples of urine and faeces were collected. Anion exchange chromatography was used for the separation of Pu. We investigated a technique to purify and separate Pu and Am isotopes using extraction chromatography with TRU resin. We tested different procedures to dissolve organic matter and eliminate interferences for chromatographic elution. At the end of the proces we have succeeded in electroplating the two radionuclides separately. We have also studied extraction chromatography with UTEVA resin to purify Pu isotopes and separate it from natural uranium radioisotopes, present in some biological samples. We validated a method for the determination of Pu in biological samples and a rather constant chemical yield and resolved peaks were obtained. The preliminary studies on TRU resin have indicated that it is possible to combine extraction and anion-exchange chromatography for analysing separately Pu and Am isotopes from the same sample aliquote.

  9. Structural and microstructural changes during anion exchange of CoAl layered double hydroxides: an in situ X-ray powder diffraction study

    DEFF Research Database (Denmark)

    Johnsen, Rune; Krumeich, Frank; Norby, Poul

    2010-01-01

    Anion-exchange processes in cobalt-aluminium layered double hydroxides (LDHs) were studied by in situ synchrotron X-ray powder diffraction (XRPD). The processes investigated were CoAl-CO3 CoAl-Cl CoAl-CO3, CoAl-Cl CoAl-NO3 and CoAl-CO3 CoAl-SO4. The XRPD data show that the CoAl-CO3 CoAl-Cl process...

  10. Hybrid organic-inorganic anion-exchange pore-filled membranes for the recovery of nitric acid from highly acidic aqueous waste streams.

    Science.gov (United States)

    Chavan, Vivek; Agarwal, Chhavi; Adya, V C; Pandey, Ashok K

    2018-04-15

    Recycling of acid from aqueous waste streams is highly important not only from the environmental point of view but also for developing the sustainable technology. One of the effective ways to recover acid from aqueous waste streams is the anion-exchange membrane based diffusion-dialysis. The work presents the synthesis and characterization of anion-exchange pore-filled membranes for the objective of recovery of high concentration of acid by diffusion dialysis. The membranes were prepared by anchoring the guest organic-inorganic anionic gel in the pores of the host poly(propylene) membrane by in situ UV-initiator induced polymerization of the appropriate monomers along with cross-linker. The removal of nitric acid in the presence of different representative monovalent, divalent and trivalent nitrates and the leakage of these ions through anion exchange membrane have been studied by DD technique for optimizing the chemical composition of the membrane. The nitric acid permeation rate of the membrane with the optimized composition has been found to be considerably faster than the commercial Selemion membrane without sacrificing salt leakage. The performance of the optimized pore-filled anion exchange membranes has been found to be independent of the acid concentration, nature of the anion and substrate and has been observed to be solely dependent on the guest inorganic-organic hybrid anionic gel component. The membranes have been found to be stable and reusable for the acid recovery. Removal of nitric acid as high as 90% from the simulated high level nuclear waste with the optimized grafted pore-filled membrane has been achieved with negligible salt transport. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Homogeneous Coating with an Anion-Exchange Ionomer Improves the Cycling Stability of Secondary Batteries with Zinc Anodes.

    Science.gov (United States)

    Stock, Daniel; Dongmo, Saustin; Walther, Felix; Sann, Joachim; Janek, Jürgen; Schröder, Daniel

    2018-03-14

    Limited cycling stability of secondary cells with zinc anodes arises mainly from the high solubility of oxidized zinc species in the alkaline electrolyte resulting in electrode shape change and loss of active material during repeated discharge and charge. We propose and successfully employ a homogeneous coating with an anion-exchange ionomer (AEI) on model electrodes with electron-conductive host structures to confine the oxidized zinc species. Ideally, the confinement of oxidized zinc species reduces the shape change of the electrode and keeps the active material as close as possible at its place of origin. In this work, the confinement concept for the oxidized zinc species is elucidated by means of electrochemical studies and X-ray photoelectron spectroscopy: as intended, an interlayer of zinc oxide forms between the AEI and the surface of the zinc electrode. This interlayer implies that the hydroxide ions are able to pass and react as intended, whereas the migration of oxidized zinc species into the bulk electrolyte is hindered. The coating with an AEI yields a higher amount of restored zinc during electrodeposition in comparison to an uncoated zinc electrode-applying an AEI coating increases the achievable cycle number by up to six times. We investigate the morphology of the cycled electrodes and derive thereby the needs for further material classes that might be employed in the confinement concept. This approach demonstrates the benefit of ion-selective coatings, allowing for the permeation of hydroxide ions but not of oxidized zinc species, a concept which improves rechargeable batteries with zinc anodes, such as zinc-oxygen batteries.

  12. Simplified production and concentration of HIV-1-based lentiviral vectors using HYPERFlask vessels and anion exchange membrane chromatography

    Directory of Open Access Journals (Sweden)

    Marino Michael P

    2009-02-01

    Full Text Available Abstract Background During the past twelve years, lentiviral (LV vectors have emerged as valuable tools for transgene delivery because of their ability to transduce nondividing cells and their capacity to sustain long-term transgene expression in target cells in vitro and in vivo. However, despite significant progress, the production and concentration of high-titer, high-quality LV vector stocks is still cumbersome and costly. Methods Here we present a simplified protocol for LV vector production on a laboratory scale using HYPERFlask vessels. HYPERFlask vessels are high-yield, high-performance flasks that utilize a multilayered gas permeable growth surface for efficient gas exchange, allowing convenient production of high-titer LV vectors. For subsequent concentration of LV vector stocks produced in this way, we describe a facile protocol involving Mustang Q anion exchange membrane chromatography. Results Our results show that unconcentrated LV vector stocks with titers in excess of 108 transduction units (TU per ml were obtained using HYPERFlasks and that these titers were higher than those produced in parallel using regular 150-cm2 tissue culture dishes. We also show that up to 500 ml of an unconcentrated LV vector stock prepared using a HYPERFlask vessel could be concentrated using a single Mustang Q Acrodisc with a membrane volume of 0.18 ml. Up to 5.3 × 1010 TU were recovered from a single HYPERFlask vessel. Conclusion The protocol described here is easy to implement and should facilitate high-titer LV vector production for preclinical studies in animal models without the need for multiple tissue culture dishes and ultracentrifugation-based concentration protocols.

  13. Radiotracer application for characterization of nuclear grade anion exchange resins Tulsion A-23 and Dowex SBR LC

    International Nuclear Information System (INIS)

    Singare, P.U.

    2015-01-01

    Radio isotopic tracer technique as one of the versatile nondestructive technique is employed to evaluate the performance of nuclear grade anion exchange resins Tulsion A-23 and Dowex SBR LC. The evaluation was made on the basis of ion-isotopic exchange reaction kinetics by using 131 I and 82 Br radioactive tracer isotopes. It was observed that for both the resins, the values of specific reaction rate (min -1 ), amount of ion exchanged (mmol) and initial rate of ion exchange (mmol/min) were calculated to be lower for bromide ion-isotopic exchange reaction than that for iodide ion-isotopic exchange reaction. It was observed that for iodide ion-isotopic exchange reaction under identical experimental conditions of 30.0 C, 1.000 g of ion exchange resins and 0.001 mol/L labeled iodide ion solution, the values of specific reaction rate (min -1 ), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log K d were calculated as 0.377, 0.212, 0.080 and 15.5 respectively for Dowex SBR LC resin, which was higher than 0.215, 0.144, 0.031 and 14.1 respectively as that obtained for Tulsion A23 resins. Also at a constant temperature of 30.0 C, as the concentration of labeled iodide ion solution increases from 0.001 mol/L to 0.004 mol/L, the percentage of iodide ions exchanged increases from 84.75 % to 90.20 % for Dowex SBR LC resins which was higher than increases from 57.66 % to 62.38 % obtained for Tulsion A23 resins. The identical trend was observed for the two resins during bromide ion-isotopic exchange reaction. The overall results indicate superior performance of Dowex SBR LC over Tulsion A23 resins under identical experimental conditions.

  14. Raman spectroscopic study of the aging and nitration of actinide processing anion-exchange resins in concentrated nitric acid

    International Nuclear Information System (INIS)

    Buscher, C. T.; Donohoe, R. J.; Mecklenburg, S. L.; Berg, J. M.; Tait, C. D.; Huchton, K. M.; Morris, D. E.

    1999-01-01

    Degradation of two types of anion exchange resins, Dowex 11 and Reillex HPQ, from the action of concentrated nitric acid (4 to 12 M) and radiolysis [from depleted uranium as UO 2 2+ nitrate species and 239 Pu as Pu(IV) nitrate species] was followed as a function of time with Raman vibrational spectroscopy. Elevated temperatures (∼50 degree sign C) were used in the absence of actinide metal loading to simulate longer exposures of the resin to a HNO 3 process stream and waste storage conditions. In the absence of actinide loading, only minor changes in the Dowex resin at acid concentrations ≤10 M were observed, while at 12 M acid concentration, the emergence of a Raman peak at 1345 cm-1 indicates the addition of nitro functional groups to the resin. Similar studies with the Reillex resin show it to be more resistant to nitric acid attack at all acid concentrations. Incorporation of weakly radioactive depleted uranium as the UO 2 2+ nitrate species to the ion-exchange sites of Dowex 11 under differing nitric acid concentrations (6 to 12 M) at room temperature showed no Raman evidence of resin degradation or nitration, even after several hundred days of contact. In contrast, Raman spectra for Dowex 11 in the presence of 239 Pu as Pu(IV) nitrate species reveal numerous changes indicating resin alterations, including a new mode at 1345 cm-1 consistent with a Pu(IV)-nitrate catalyzed addition of nitro groups to the resin backbone. (c) 2000 Society for Applied Spectroscopy

  15. Separation of metallic elements using anion exchange resins. I. Study of the fixation of several chloride complexes

    International Nuclear Information System (INIS)

    Tremillon, Bernard

    1961-01-01

    Elements forming anionic complexes may be fixed in an anion exchange resin and, among these elements, zinc, cadmium and mercury chlorides, which fixation have been quantitatively studied. The element may pass in the resin under the form of three main complexes species, MCl 2 , MCl 3 - et MCl 4 2- . Fixation of MCl 2 in the resin notably results from a partition by Donnan equilibrium. Considering the various equilibrium involved, it appears that the element fixation is maximum when its proportion, in the initial aqueous solution, in the form of the non charged non charge MCl 2 complex, is maximum. This point is correctly verified by experiments. Curves representing the concentration of the element in the resin have been established as a function of the solution concentration for various sodium chloride concentrations. The interpretation of these curves show that cadmium is fixed in the resin quasi-exclusively in the form CdCl 4 2- ; zinc is fixed in the both forms ZnCl 3 - and ZnCl 4 2- , however much less energetically; the transformation of mercury in the form HgCl 2 enables a much more energetic fixation than for the two others. Fixation of an element may be predicted knowing the formation reactions of complexes in solution. The use of a mixed water-acetone solvent, with its lower dielectric constant, stabilizes the complexes and facilitates the fixation of the element in the resin. Zinc chloride is fixed much more energetically in the presence of acetone, mainly in the form ZnCl 4 2- . Split curves enable to find the split coefficient values observed in the conditions of elution. Reprint of a paper published in 'Bulletin de la Societe Chimique de France', 1961, p. 275-281 [fr

  16. Simplified production and concentration of HIV-1-based lentiviral vectors using HYPERFlask vessels and anion exchange membrane chromatography

    Science.gov (United States)

    Kutner, Robert H; Puthli, Sharon; Marino, Michael P; Reiser, Jakob

    2009-01-01

    Background During the past twelve years, lentiviral (LV) vectors have emerged as valuable tools for transgene delivery because of their ability to transduce nondividing cells and their capacity to sustain long-term transgene expression in target cells in vitro and in vivo. However, despite significant progress, the production and concentration of high-titer, high-quality LV vector stocks is still cumbersome and costly. Methods Here we present a simplified protocol for LV vector production on a laboratory scale using HYPERFlask vessels. HYPERFlask vessels are high-yield, high-performance flasks that utilize a multilayered gas permeable growth surface for efficient gas exchange, allowing convenient production of high-titer LV vectors. For subsequent concentration of LV vector stocks produced in this way, we describe a facile protocol involving Mustang Q anion exchange membrane chromatography. Results Our results show that unconcentrated LV vector stocks with titers in excess of 108 transduction units (TU) per ml were obtained using HYPERFlasks and that these titers were higher than those produced in parallel using regular 150-cm2 tissue culture dishes. We also show that up to 500 ml of an unconcentrated LV vector stock prepared using a HYPERFlask vessel could be concentrated using a single Mustang Q Acrodisc with a membrane volume of 0.18 ml. Up to 5.3 × 1010 TU were recovered from a single HYPERFlask vessel. Conclusion The protocol described here is easy to implement and should facilitate high-titer LV vector production for preclinical studies in animal models without the need for multiple tissue culture dishes and ultracentrifugation-based concentration protocols. PMID:19220915

  17. Characteristics of an elongated plasma column produced by magnetically coupled hollow cathode plasma source

    Science.gov (United States)

    Bhuva, M. P.; Karkari, S. K.; Kumar, Sunil

    2018-03-01

    An elongated plasma column in the presence of an axial magnetic field has been formed using a cylindrical hollow cathode (HC) and a constricted anode (CA). The plasma characteristics of the central line have been found to vary with the magnetic field strength and the axial distance from the source. It is believed that the primary electrons constituting the discharge current are steered by the axial magnetic field to undertake ionizing collisions along the plasma column. The current carrying electrons from the HC reach the anode by cross-field diffusion towards the central line. The above observation has been substantiated using a phenomenological model which links the observed characteristics of the source with the plasma column. The experimental results are found to be in qualitative agreement with the model.

  18. Carbon, nitrogen, oxygen and sulfide budgets in the Black Sea : a biogeochemical model of the whole water column coupling the oxic and anoxic parts

    NARCIS (Netherlands)

    Grégoire, M.; Soetaert, K.E.R.

    2010-01-01

    Carbon, nitrogen, oxygen and sulfide budgets are derived for the Black Sea water column from a coupled physical–biogeochemical model. The model is applied in the deep part of the sea and simulates processes over the whole water column including the anoxic layer that extends from similar, equals115 m

  19. Relationship Advice Columns from Two Popular Magazines: Implications for Therapy with Women, Men and Heterosexual Couples

    Science.gov (United States)

    Kogan, Lori R.; Kellaway, Julie A.

    2004-01-01

    The relationship advice columns for two popular magazines (one targeted to female and the other to male readers) were discussed within the conceptual frameworks of centerfold syndrome and appearance obsession. Centerfold syndrome is a theory that describes the way men view women and sexuality. The female counterpart is appearance obsession which…

  20. Determination of sulfonamides in serum by on-line solid-phase extraction coupled to liquid chromatography with photoinduced fluorescence detection.

    Science.gov (United States)

    Arroyo-Manzanares, Natalia; Lara, Francisco J; Airado-Rodríguez, Diego; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2015-06-01

    An analytical method based on on-line solid-phase extraction coupled to liquid chromatography with photoinduced fluorescence detection has been developed to determine sulfonamides in serum. A home-made setup was used to percolate 3 mL of sample through a solid-phase extraction column. Analytes were retained onto the sorbent by an anion exchange mechanism which ensures an optimum compatibility with the subsequent chromatographic separation using a C-18 column and an on-line photoreactor in order to derivatize sulfonamides, which do not present native fluorescence. The method allowed the determination of 7 sulfonamides in serum samples previously deproteinized in less than 18 min and with limits of detection ranging between 1.8 and 3.6 mg/L. Relative recoveries between 91.5% and 102.1% were obtained with satisfactory precision since relative standard deviations were always below 10.5%. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. The setup of an extraction system coupled to a hydrogen isotopes distillation column

    International Nuclear Information System (INIS)

    Zamfirache, M.; Bornea, A.; Stefanescu, I.; Bidica, N.; Balteanu, O.; Bucur, C.

    2008-01-01

    Among the most difficult problems of cryogenic distillation one stands apart: the extraction of the heavy fraction. By an optimal design of the cycle scheme, this problem could be avoided. A 'worst case scenario' is usually occurring when the extracted fraction consists of one prevalent isotope such as hydrogen and small amounts of the other two hydrogen isotopes (deuterium and/or tritium). This situation is further complicated by two parameters of the distillation column: the extraction flow rate and the hold-up. The present work proposes the conceptual design of an extraction system associated to the cryogenic distillation column used in hydrogen separation processes. During this process, the heavy fraction (DT, T 2 ) is separated, its concentration being the highest at the bottom of the distillation column. From this place the extraction of the gaseous phase can now begin. Being filled with adsorbent, the extraction system is used to temporarily store the heavy fraction. Also the extraction system provides samples for the gas Chromatograph. The research work is focused on the existent pilot plant for tritium and deuterium separation from our institute to validate the experiments carried out until now. (authors)

  2. Determination of Common Adulterants in Herbal Medicine and Food Samples using Core-shell Column Coupled to Tandem Mass Spectrometry.

    Science.gov (United States)

    Al Lawati, Haider A J; Al Busaidi, Idris; Kadavilpparampu, Afsal M; Suliman, FakhrEldin O

    2017-03-01

    High-performance liquid chromatography coupled to tandem mass spectrometry was used to develop and validate a rapid method to qualitatively and quantitatively analyse 18 common adulterants in herbal medicine and food samples. Initially, the mobile phase composition was optimized in three different columns: core-shell, monolithic and standard 3.5-µm-particle-size columns. The results show that the core-shell column provides the best separation. Moreover, the tandem mass spectrometry was optimized. The linear range for all adulterants was 0.5-500 μg mL-1. Finally, the samples that were supplied by the Public Authority of Customer Protection, Ministry of Health, and those collected from the local market were analysed. The results indicate that 7 of 33 analysed samples contained adulterants. The adulterated samples mainly contain sildenafil, tadalafil or vardenafil. The concentrations of these three adulterants in the samples were 0.18-39 wt%. This study is the first report in the Sultanate of Oman about adulteration in herbal medicine and food samples. The results clearly raise some concern and require proper plan of action to increase public awareness about this serious issue. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Sorption of Cr(VI) ions on two Lewatit-anion exchange resins and their quantitative determination using UV-visible spectrophotometer.

    Science.gov (United States)

    Pehlivan, E; Cetin, S

    2009-04-15

    The sorption of Cr(VI) from aqueous solutions with macroporous resins which contain quarternary amine groups (Lewatit MP 64 and Lewatit MP 500) was studied at varying Cr(VI) concentration, adsorbent dose, pH, contact time and temperature. Batch shaking sorption experiments were carried out to evaluate the performance of Lewatit MP 64 and Lewatit MP 500 anion exchange resins in the removal of Cr(VI) from aqueous solutions. The concentration of Cr(VI) in aqueous solution was determined by UV-visible spectrophotometer. The ion exchange process, which is dependent on pH, showed maximum removal of Cr(VI) in the pH range 3-7 for an initial Cr(VI) concentration of 1x10(-3) M. The optimum pH for Cr(VI) adsorption was found as 5.0 for Lewatit MP 64 and 6.0 for Lewatit MP 500. The maximum Cr(VI) adsorption at pH 5.0 is 0.40 and 0.41 mmol/g resin for Lewatit MP 64 and Lewatit MP 500 anion exchangers, respectively. The maximum chromium sorption occurred at approximately 60 min for Lewatit MP 64 and 75 min for Lewatit MP 500. The suitability of the Freundlich and Langmuir adsorption models was also investigated for each chromium-sorbent system. The uptake of Cr(VI) by the anion exchange resins was reversible and so it has good potential for the removal of Cr(VI) from aqueous solutions. Both ion exchangers had high bonding constants but Lewatit MP 500 showed stronger binding. The rise in the temperature caused a slight decrease in the value of the equilibrium constant (K(c)) for the sorption of Cr(VI) ion.

  4. Sodium citrate-assisted anion exchange strategy for construction of Bi{sub 2}O{sub 2}CO{sub 3}/BiOI photocatalysts

    Energy Technology Data Exchange (ETDEWEB)

    Song, Peng-Yuan; Xu, Ming; Zhang, Wei-De, E-mail: zhangwd@scut.edu.cn

    2015-02-15

    Highlights: • Heterostructured Bi{sub 2}O{sub 2}CO{sub 3}/BiOI microspheres were prepared via anion exchange. • Sodium citrate-assisted anion exchange for construction of composite photocatalysts. • Bi{sub 2}O{sub 2}CO{sub 3}/BiOI composites show high visible light photocatalytic activity. - Abstract: Bi{sub 2}O{sub 2}CO{sub 3}/BiOI heterojuncted photocatalysts were constructed through a facile partial anion exchange strategy starting from BiOI microspheres and urea with the assistance of sodium citrate. The content of Bi{sub 2}O{sub 2}CO{sub 3} in the catalysts was regulated by modulating the amount of urea as a precursor, which was decomposed to generate CO{sub 3}{sup 2−} in the hydrothermal process. Citrate anion plays a key role in controlling the morphology and composition of the products. The Bi{sub 2}O{sub 2}CO{sub 3}/BiOI catalysts display much higher photocatalytic activity than pure BiOI and Bi{sub 2}O{sub 2}CO{sub 3} towards the degradation of rhodamine B (RhB) and bisphenol A (BPA). The enhancement of photocatalytic activity of the heterojuncted catalysts is attributed to the formation of p–n junction between p-BiOI and n-Bi{sub 2}O{sub 2}CO{sub 3}, which is favorable for retarding the recombination of photoinduced electron-hole pairs. Moreover, the holes are demonstrated to be the main active species for the degradation of RhB and BPA.

  5. Effects of pH, conductivity, host cell protein, and DNA size distribution on DNA clearance in anion exchange chromatography media.

    Science.gov (United States)

    Stone, Melani C; Borman, Jon; Ferreira, Gisela; Robbins, P David

    2018-01-01

    Flowthrough anion exchange chromatography is commonly used as a polishing step in downstream processing of monoclonal antibodies and other therapeutic proteins to remove process-related impurities and contaminants such as host cell DNA, host cell proteins, endotoxin, and viruses. DNA with a wide range of molecular weight distributions derived from Chinese Hamster Ovary cells was used to advance the understanding of DNA binding behavior in selected anion exchange media using the resin (Toyopearl SuperQ-650M) and membranes (Mustang® Q and Sartobind® Q) through DNA spiking studies. The impacts of the process parameters pH (6-8), conductivity (2-15 mS/cm), and the potential binding competition between host cell proteins and host cell DNA were studied. Studies were conducted at the least and most favorable experimental conditions for DNA binding based on the anticipated electrostatic interactions between the host cell DNA and the resin ligand. The resin showed 50% higher DNA binding capacity compared to the membrane media. Spiking host cell proteins in the load material showed no impact on the DNA clearance capability of the anion exchange media. DNA size distributions were characterized based on a "size exclusion qPCR assay." Results showed preferential binding of larger DNA fragments (>409 base pairs). © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 34:141-149, 2018. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.

  6. Layered rare-earth hydroxide nanocones with facile host composition modification and anion-exchange feature: topotactic transformation into oxide nanocones for upconversion.

    Science.gov (United States)

    Zhong, Yishun; Chen, Gen; Liu, Xiaohe; Zhang, Dan; Zhang, Ning; Li, Junhui; Liang, Shuquan; Ma, Renzhi; Qiu, Guanzhou

    2017-06-22

    Conical structures with hollow interiors, namely, nanocones (NCs), may exhibit better carrier transport properties than nanorods or nanotubes, which make them promising candidates for potential applications in optical/display devices, electronics and optoelectronics. Generally, conical structures belong to a metastable state between lamellar and tubular forms due to the extreme curvature causing the increase of internal strain energy. Therefore, it is very difficult to prepare NCs in high yield and purity under mild conditions. Here we firstly demonstrate a general strategy for the synthesis of layered rare-earth hydroxide (LRH) NCs intercalating dodecyl sulfate anions (C 12 H 25 SO 4 - , DS - ) using hexamethylenetetramine (C 6 H 12 N 4 , HMT) hydrolysis. The rare-earth cations (RE 3+ ) in the host layer can be conveniently modified and/or doped, resulting in a large family of monometallic (Y, Tb, Er), bi- (Y-Tb, Y-Er) and even tri-metallic (Y-Yb-Er) LRH NCs with adjustable ratios. Moreover, the DS - -intercalated LRH NCs can be readily modified with various inorganic or organic anions (e.g., NO 3 - , Cl - , and CH 3 COO - , etc.) through a conventional anion-exchange procedure, and the original conical morphology can be perfectly maintained. The anion-exchanged product, for example, NO 3 - -intercalated NCs, can be more easily and topotactically transformed into oxide NCs than the original DS - -intercalated form, exempt from the formation of rare-earth oxysulfates induced by the combustion of interlayer DS anions. Taking advantage of this protocol, tri-metallic (Y-Yb-Er) LRH NCs were anion-exchanged into the NO 3 - -intercalated form and subsequently calcined into Y 2 O 3 :Yb,Er oxide NCs, which showed efficient upconversion photoluminescence properties. The current strategy may become a general method for the designed synthesis of other related hydroxide and oxide NCs for a wide range of potential applications.

  7. Complexation of uranyl ions. III. Investigation of the sorption of uranium of the VP-1Ap anion exchanger from carbonate media by x-ray spectrometric microanalysis

    International Nuclear Information System (INIS)

    Komarova, N.I.; Kakhaeva, T.V.; Kvaratskheli, Yu.K.; Vodolazov, L.I.; Rodionov, V.V.

    1987-01-01

    The spatial distribution of uranium in granules of the VP-1Ap anion exchanger during heightened sorption from carbonate media has been investigated by x-ray spectroscopic microanalysis. Variation of the form of the concentration profile as a function of the extent of sorption from a uniform profile across the diameter, then to a meniscus-shaped profile, and finally to a smoothed profile with an increase in the coefficient of nonuniformity of the distribution of uranium in the granules from 0.026 to 0.045 has been established

  8. Determination of mycophenolic acid in mest products using mixed mode reversed phase-anion exchange clean-up and liquid chromatography-high-resolution mass spectrometry

    DEFF Research Database (Denmark)

    Sørensen, Louise Marie; Nielsen, Kristian Fog; Jacobsen, Thomas

    2008-01-01

    A method for determination of mycophenolic acid (MPA) in dry-cured ham, fermented sausage and liver pate is described. MPA was extracted from meat with bicarbonate-acetonitrile, further cleaned-up by mixed mode reversed phase-anion exchange and detected using a LC-MS system with electrospray...... ionisation-time-of-flight detection. The limit of detection was 4 mu g/kg in sausage and 6 mu g/kg in ham and pate. The method was successfully used for quantification of MPA in dry-cured ham and liver pate artificially inoculated with Penicillium brevicompactum. Levels ranged from 190 mu g/kg in centre to I...

  9. Dialysis is superior to anion exchange for removal of dissolved inorganic nitrogen from freshwater samples prior to dissolved organic nitrogen determination

    DEFF Research Database (Denmark)

    Graeber, Daniel; Gücker, Björn; Zwirnmann, Elke

    2012-01-01

    Dissolved organic nitrogen (DON) is usually determined as the difference between total dissolved nitrogen (TDN) and dissolved inorganic nitrogen (DIN). When applying this approach to samples with high DIN concentrations, there is a risk, that small relative errors in TDN and DIN measurements may...... propagate into high absolute errors of the determined DON concentration. To reduce such errors, two pretreatment methods have been suggested for the removal of DIN prior to the determination of DON: anion-exchange pretreatment (AEP) and dialysis pretreatment (DP). In this study, we tested the suitability...

  10. Structural and microstructural changes during anion exchange of CoAl layered double hydroxides. An in situ X-ray powder diffraction study

    International Nuclear Information System (INIS)

    Johnsen, Rune E.; Krumeich, Frank; Norby, Poul

    2010-01-01

    Anion-exchange processes in cobalt-aluminium layered double hydroxides (LDHs) were studied by in situ synchrotron X-ray powder diffraction (XRPD). The processes investigated were CoAl-CO 3 →CoAl-Cl →CoAl-CO 3 , CoAl-Cl→CoAl-NO 3 and CoAl-CO 3 →CoAl-SO 4 . The XRPD data show that the CoAl-CO 3 →CoAl-Cl process is a two-phase transformation, where the amount of the CoAl-CO 3 phase decreases exponentially while that of the CoAl-Cl phase increases exponentially. Energy-dispersive X-ray spectroscopy (EDXS) studies of a partially chloride-exchanged CoAl-CO 3 LDH sample along with in situ XRPD data suggested that the individual particles in the CoAl-CO 3 sample are generally anion-exchanged with chloride one at a time. In contrast with the CoAl-CO 3 →CoAl-Cl transformation, the XRPD data show that the reverse CoAl-Cl→CoAl-CO 3 process is a one-phase transformation. Rietveld refinements indicate that the occupancy factors of the carbon and oxygen sites of the carbonate group increase, while that of the chloride site decreases. In the CoAl-Cl→CoAl-NO 3 anion-exchange reaction, the XRPD patterns reveal the existence of two intermediate phases in addition to the initial CoAl-Cl and final CoAl-NO 3 phases. The in situ data indicate that one of these intermediates is a mixed nitrate- and chloride-based LDH phase, where the disorder decreases as the nitrate content increases. The XRPD data of the partial CoAl-CO 3 →CoAl-SO 4 anion-exchange reaction show that the process is a two-phase transformation involving a sulfate-containing LDH with a 1H polytype structure. (orig.)

  11. Single-Crystal-to-Single-Crystal Anion Exchange in a Gadolinium MOF: Incorporation of POMs and [AuCl4]−

    Directory of Open Access Journals (Sweden)

    Javier López-Cabrelles

    2016-04-01

    Full Text Available The encapsulation of functional molecules inside porous coordination polymers (also known as metal-organic frameworks, MOFs has become of great interest in recent years at the field of multifunctional materials. In this article, we present a study of the effects of size and charge in the anion exchange process of a Gd based MOF, involving molecular species like polyoxometalates (POMs, and [AuCl4]−. This post-synthetic modification has been characterized by IR, EDAX, and single crystal diffraction, which have provided unequivocal evidence of the location of the anion molecules in the framework.

  12. Breakthrough properties of chloride ions in columns of lead phosphate hydroxide

    International Nuclear Information System (INIS)

    Akiba, Kenichi; Hashimoto, Hiroyuki; Mimura, Hitoshi; Shindo, Manabu.

    1994-01-01

    Breakthrough properties of chloride ion (Cl - ) have been studied by using columns packed with a granular anion-exchanger of lead phosphate hydroxide (Pb 10 (PO 4 ) 6 (OH) 2 , IXE-1000G). The column utilization of the ratio of breakthrough capacity to total capacity increased with decreasing particle size and increasing temperature. The collection of Cl - from a simulated waste solution was improved by the addition of cation-exchange to IXE-1000G; the adsorption capacity of the column of IXE-1000G/IXE-300G (Sb type cation-exchanger) was over 0.16 mmol Cl - /g, yielding a relatively high column utilization of 75%. (author)

  13. Combination of Na-modified zeolite and anion exchange resin for advanced treatment of a high ammonia-nitrogen content municipal effluent.

    Science.gov (United States)

    Zhang, Haiyun; Li, Aimin; Zhang, Wei; Shuang, Chendong

    2016-04-15

    In this study, the exchange equilibrium and kinetic experiments of ammonia-nitrogen on the Na-form zeolite were conducted. The results indicated that the presence of humic acid have a negative effect on the equilibrium exchange capacity but have limited influence on the equilibrium time except shorten the sole intra-particle diffusion control time. The exchange equilibrium data could be well fitted by Freundlich model in the absence of humic acid but Langmuir model in the presence of humic acid. While the exchange kinetic data could be well described by pseudo-second-order kinetic model in both situations. An anion exchange resin exhibited high removal efficiency to humic acid and dissolved organic matter through kinetic results and fluorescence excitation-emission matrix (EEM) spectroscopy results. The use of the anion exchange resin prior to the Na-form zeolite improved the ammonia-nitrogen removal efficiency from 78% to 95% and increased the treatment volume of the Na-form zeolite from 51 BV (bed volume) to 76 BV. Both the resin and the Na-form zeolite could be successfully regenerated by the combination of alkaline and sodium chloride. Complete elution of ammonia-nitrogen was achieved when the mass percentage of sodium chloride and alkaline was 10% and 0.6% respectively. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Efficient in situ separation and production of L-lactic acid by Bacillus coagulans using weak basic anion-exchange resin.

    Science.gov (United States)

    Zhang, Yitong; Qian, Zijun; Liu, Peng; Liu, Lei; Zheng, Zhaojuan; Ouyang, Jia

    2018-02-01

    To get rid of the dependence on lactic acid neutralizer, a simple and economical approach for efficient in situ separation and production of L-lactic acid was established by Bacillus coagulans using weak basic anion-exchange resin. During ten tested resins, the 335 weak basic anion-exchange resins demonstrated the highest adsorption capacity and selectivity for lactic acid recovery. The adsorption study of the 335 resins for lactic acid confirmed that it is an efficient adsorbent under fermentation condition. Langmuir models gave a good fit to the equilibrium data at 50 °C and the maximum adsorption capacity for lactic acid by 335 resins was about 402 mg/g. Adsorption kinetic experiments showed that pseudo-second-order kinetics model gave a good fit to the adsorption rate. When it was used for in situ fermentation, the yield of L-lactic acid by B. coagulans CC17 was close to traditional fermentation and still maintained at about 82% even after reuse by ten times. These results indicated that in situ separation and production of L-lactic acid using the 335 resins were efficient and feasible. This process could greatly reduce the dosage of neutralizing agent and potentially be used in industry.

  15. Anion exchange chromatography of 99mTc(Sn)-EHDP complexes: determination of the charge of the components and influence of pH and ligand concentration

    International Nuclear Information System (INIS)

    Huigen, Y.M.; Diender, M.; Gelsema, W.J.; De Ligny, C.L.

    1991-01-01

    The components of a 99m Tc(Sn)-EHDP complex mixture were separated by means of normal pressure and high-pressure anion exchange chromatography. Precautions were taken to prevent the dissociation of the complexes during chromatography. The charges of the components were determined according to the methods of Wilson and Pinkerton (1985) and Russell and Bischoff (1985). The values of the charges obtained with the two methods are not in agreement. Russell and Bischoff's method, in which a reference ion is used, must be preferred. However, even with this method the accuracy of the data obtained is probably limited, due to the difficulty of making corrections for activity coefficients of highly-charge ions at the rather high electrolyte concentrations that must be used in the ion exchange method. So, we think that it is only warranted to conclude that the mean charge of the components of 99m Tc(Sn)-EHDP is about -6 at pH 7, and that the charges of the individual components are in the range of -4 to -9. The influence of pH and ligand concentration in the reaction mixture was determined with high pressure anion exchange chromatography. It was found that a decrease in the pH of the reaction mixture favours the production of complexes with a long retention time, which leads to a slightly higher mean charge. The ligand concentration of the reaction mixture scarcely influenced the relative concentrations of the components. (author)

  16. Surface- vs Diffusion-Limited Mechanisms of Anion Exchange in CsPbBr3 Nanocrystal Cubes Revealed through Kinetic Studies.

    Science.gov (United States)

    Koscher, Brent A; Bronstein, Noah D; Olshansky, Jacob H; Bekenstein, Yehonadav; Alivisatos, A Paul

    2016-09-21

    Ion-exchange transformations allow access to nanocrystalline materials with compositions that are inaccessible via direct synthetic routes. However, additional mechanistic insight into the processes that govern these reactions is needed. We present evidence for the presence of two distinct mechanisms of exchange during anion exchange in CsPbX3 nanocrystals (NCs), ranging in size from 6.5 to 11.5 nm, for transformations from CsPbBr3 to CsPbCl3 or CsPbI3. These NCs exhibit bright luminescence throughout the exchange, allowing their optical properties to be observed in real time, in situ. The iodine exchange presents surface-reaction-limited exchanges allowing all anionic sites within the NC to appear chemically identical, whereas the chlorine exchange presents diffusion-limited exchanges proceeding through a more complicated exchange mechanism. Our results represent the first steps toward developing a microkinetic description of the anion exchange, with implications not only for understanding the lead halide perovskites but also for nanoscale ion exchange in general.

  17. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  18. Coupled atmosphere and land-surface assimilation of surface observations with a single column model and ensemble data assimilation

    Science.gov (United States)

    Rostkier-Edelstein, Dorita; Hacker, Joshua P.; Snyder, Chris

    2014-05-01

    Numerical weather prediction and data assimilation models are composed of coupled atmosphere and land-surface (LS) components. If possible, the assimilation procedure should be coupled so that observed information in one module is used to correct fields in the coupled module. There have been some attempts in this direction using optimal interpolation, nudging and 2/3DVAR data assimilation techniques. Aside from satellite remote sensed observations, reference height in-situ observations of temperature and moisture have been used in these studies. Among other problems, difficulties in coupled atmosphere and LS assimilation arise as a result of the different time scales characteristic of each component and the unsteady correlation between these components under varying flow conditions. Ensemble data-assimilation techniques rely on flow dependent observations-model covariances. Provided that correlations and covariances between land and atmosphere can be adequately simulated and sampled, ensemble data assimilation should enable appropriate assimilation of observations simultaneously into the atmospheric and LS states. Our aim is to explore assimilation of reference height in-situ temperature and moisture observations into the coupled atmosphere-LS modules(simultaneously) in NCAR's WRF-ARW model using the NCAR's DART ensemble data-assimilation system. Observing system simulation experiments (OSSEs) are performed using the single column model (SCM) version of WRF. Numerical experiments during a warm season are centered on an atmospheric and soil column in the South Great Plains. Synthetic observations are derived from "truth" WRF-SCM runs for a given date,initialized and forced using North American Regional Reanalyses (NARR). WRF-SCM atmospheric and LS ensembles are created by mixing the atmospheric and soil NARR profile centered on a given date with that from another day (randomly chosen from the same season) with weights drawn from a logit-normal distribution. Three

  19. Determination of selenite and selenate in human urine by ion chromatography and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jons, O.

    2000-01-01

    The selenium species selenite, selenate and selenomethionine were separated in aqueous solution by ion chromatography. The separation was performed on an IonPac AG11 in series with an AS11 anion exchange column by elution with 25 mM sodium hydroxide in 2% methanol. The Se-78 and Se-82 isotopes were...... monitored in the inductively coupled plasma mass spectrometry (ICP-MS) detector. When the chromatographic system was applied to analysis of urine samples diluted 1 + 1, the selenomethionine signal appeared in the front together with other unresolved selenium species, while the selenite and selenate signals...... and selenate, respectively, corresponding to absolute amounts of 8 and 16 pg, respectively. Calculations were based on peak height measurements of the Se-82 isotope. In 23 analysed urine samples, the concentration of selenite was in the range selenium...

  20. LAB-SCALE DEMONSTRATION OF PLUTONIUM PURIFICATION BY ANION EXCHANGE, PLUTONIUM (IV) OXALATE PRECIPITATION, AND CALCINATION TO PLUTONIUM OXIDE TO SUPPORT THE MOX FEED MISSION

    Energy Technology Data Exchange (ETDEWEB)

    Crowder, M.; Pierce, R.

    2012-08-22

    H-Canyon and HB-Line are tasked with the production of PuO{sub 2} from a feed of plutonium metal. The PuO{sub 2} will provide feed material for the MOX Fuel Fabrication Facility. After dissolution of the Pu metal in H-Canyon, the solution will be transferred to HB-Line for purification by anion exchange. Subsequent unit operations include Pu(IV) oxalate precipitation, filtration and calcination to form PuO{sub 2}. This report details the results from SRNL anion exchange, precipitation, filtration, calcination, and characterization tests, as requested by HB-Line1 and described in the task plan. This study involved an 80-g batch of Pu and employed test conditions prototypical of HB-Line conditions, wherever feasible. In addition, this study integrated lessons learned from earlier anion exchange and precipitation and calcination studies. H-Area Engineering selected direct strike Pu(IV) oxalate precipitation to produce a more dense PuO{sub 2} product than expected from Pu(III) oxalate precipitation. One benefit of the Pu(IV) approach is that it eliminates the need for reduction by ascorbic acid. The proposed HB-Line precipitation process involves a digestion time of 5 minutes after the time (44 min) required for oxalic acid addition. These were the conditions during HB-line production of neptunium oxide (NpO{sub 2}). In addition, a series of small Pu(IV) oxalate precipitation tests with different digestion times were conducted to better understand the effect of digestion time on particle size, filtration efficiency and other factors. To test the recommended process conditions, researchers performed two nearly-identical larger-scale precipitation and calcination tests. The calcined batches of PuO{sub 2} were characterized for density, specific surface area (SSA), particle size, moisture content, and impurities. Because the 3013 Standard requires that the calcination (or stabilization) process eliminate organics, characterization of PuO{sub 2} batches monitored the

  1. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: a review on instrumentation and chemistries.

    Science.gov (United States)

    Zacharis, Constantinos K; Tzanavaras, Paraskevas D

    2013-10-10

    Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular "chemistries" that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Ion exchange equilibrium for some uni-univalent and uni-divalent reaction systems using strongly basic anion exchange resin Duolite A-102 D

    Directory of Open Access Journals (Sweden)

    R.S. Lokhande

    2008-04-01

    Full Text Available The study on thermodynamics of ion exchange equilibrium for uni-univalent Cl-/I-, Cl-/Br-, and uni-divalent Cl-/SO42-, Cl-/C2O42- reaction systems was carried out using ion exchange resin Duolite A-102 D. The equilibrium constant K was calculated by taking into account the activity coefficient of ions both in solution as well as in the resin phase. The K values calculated for uni-univalent and uni-divalent anion exchange reaction systems was observed to increase with rise in temperature, indicating the endothermic exchange reactions having enthalpy values of 13.7, 38.0, 23.9, 22.9 kJ/mol, respectively.

  3. Determination of total ribonucleotide pool in plant materials by high-pH anion-exchange high-performance liquid chromatography following extraction with potassium hydroxide.

    Science.gov (United States)

    Riondet, Christophe; Morel, Sylvain; Alcaraz, Gérard

    2005-06-10

    A new, improved method that only requires a potassium hydroxide extraction procedure is presented for the analysis of a full nucleotide pool in plant materials. Quantification was performed by high-pH anion-exchange chromatography (HPAEC) with UV detection after a potassium hydroxide extraction, and allowed the quantification of 13 linear ribonucleotides in a single run. The method has been validated by comparison of six extraction methods and also by measurement of the intracellular nucleotide levels of three plant species (cell cultures and leaves). The evolution of the nucleotide pool of Nicotiana tabacum cell culture during growth has also been measured, and showed an increase in the pool until the fifth day, where the growth rate reaches a maximum, after which a decrease was observed.

  4. A study of ion exchange equilibrium for some uni-univalent and uni-divalent reaction systems using strongly basic anion exchange resin Indion-830 (Type 1)

    Science.gov (United States)

    Lokhande, R. S.; Singare, P. U.; Patil, A. B.

    2007-12-01

    A study of the thermodynamics of ion exchange equilibrium for uni-univalent Cl-/I-, Cl-/Br- and uni-divalent Cl-/SO{4/2-}, Cl-/C2O{4/2-} reaction systems was carried out using ion exchange resin Indion-830 (Type 1). The equilibrium constant K was calculated by taking into account the activity coefficients of ions both in solution and in the resin phase. For uni-univalent ion exchange reaction systems, the equilibrium constants K' were also calculated from the mole fraction of ions in the resin phase. The K values calculated for uni-univalent and uni-divalent anion exchange reaction systems increased as the temperature grew, indicating the endothermic character of the exchange reactions with enthalpies of 38.2, 32.3, 7.6, and 11.4 kJ/mol, respectively.

  5. Preparation and characterization of anion exchange resin decorated with magnetite nanoparticles for removal of p-toluic acid from aqueous solution

    Science.gov (United States)

    Davarpanah, Morteza; Ahmadpour, Ali; Rohani Bastami, Tahereh

    2015-02-01

    Polystyrene resin was covalently functionalized with diethanolamine and then decorated with magnetite nanoparticles by a novel and simple co-precipitation method using iron(II) sulfate as precursor. The products were characterized by Fourier transform infrared spectroscopy, elemental analysis, X-ray diffraction, Mössbauer spectroscopy, field-emission scanning electron microscopy and vibrating sample magnetometer. Adsorption of p-toluic acid (p-TA) onto magnetite-decorated polystyrene (MAG-PS) was studied and compared with that of diethanolamine-functionalized polystyrene and a commercial anion exchange resin. Results showed that the magnetite nanoparticles with an average size of 20.4 nm were successfully formed on the surface of polystyrene resin, and MAG-PS was exhibited high affinity for the removal of p-TA.

  6. Ethylene glycol dimethacrylate cross-linking anion exchange resin as phosphate binder: effects on rat gut and digestion by small intestine contents.

    Science.gov (United States)

    Inoue, H

    2001-06-01

    In the present study, ethylene glycol dimethacrylate cross-linking 4-vinylpyridinium anion exchange resin (EGDMA-4VP) effectively bound dietary phosphate in normal rats. However, EGDMA-4VP induced more adverse effects in rat gut than cellulose or Dowex 1X2 (both of which have higher water content), and caused damage to the intestine. In order to resolve this seeming paradox, digestion of EGDMA-4VP with rat small intestine content (S-9 fraction) and carboxyl esterase was investigated in vitro to examine the stability of the resin under conditions it would be subjected to as an orally administered medicine. EGDMA-4VP was digested by small intestinal enzymes, with the exception of carboxyl esterase, and the degradation product ethylene glycol (EG) caused reversible relaxation of longitudinal muscle (but not circular muscle) in rat small intestine. Degradation products increased uptake of 3H2O into primary cultured rat small intestinal muscle cells, but the increase was not significant.

  7. Use of serially coupled capillary columns with different polarity of stationary phases for the separation of the natural complex volatile mixture of the marine red alga Corallina elongata.

    Science.gov (United States)

    Dembitsky, V M; Srebnik, M

    2002-09-01

    Separation of a complex of natural volatile compounds using serially coupled capillary columns with different polarity of stationary phases by gas chromatography-mass spectrometry from the medicinal marine red alga Corallina elongata is reported. Nearly 200 hydrocarbons, halogen compounds, fatty acids, and other metabolites were found. Using this gas chromatography procedure we demonstrate the successful separation of different volatile organic compounds.

  8. Automation of column-based radiochemical separations. A comparison of fluidic, robotic, and hybrid architectures

    Energy Technology Data Exchange (ETDEWEB)

    Grate, J.W.; O' Hara, M.J.; Farawila, A.F.; Ozanich, R.M.; Owsley, S.L. [Pacific Northwest National Laboratory, Richland, WA (United States)

    2011-07-01

    Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on using disposable components so that no sample contacts any surface that any other sample has contacted, and setting up samples and columns in parallel for subsequent automated processing. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions one of four rows of six vials below the columns. The samples are delivered to each column via a manual 3-port disposable valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is a simpler more efficient approach for performing anion exchange procedures for the recovery and purification of plutonium from samples. The automation architectures described can also be adapted to column-based extraction chromatography separations. (orig.)

  9. Design and fabrication of enhanced corrosion resistance Zn-Al layered double hydroxides films based anion-exchange mechanism on magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Meng; Yan, Luchun; Ling, Hao; Diao, Yupeng; Pang, Xiaolu; Wang, Yanlin; Gao, Kewei, E-mail: kwgao@yahoo.com

    2017-05-15

    Highlights: • Zn-Al LDHs film loaded nitrate anions has been fabricated on a magnesium alloy substrate via a facile hydrothermal crystallization method. • The Zn-Al-Cl LDHs and Zn-Al-VO{sub x} LDHs film were obtained based on anion-exchange mechanism. • The Zn-Al-Cl LDHs and Zn-Al-VO{sub x} LDHs film could effectively protect magnesium alloy. - Abstract: Layered double hydroxides (LDHs) with brucite-like layer structure and the facile exchangeability of intercalated anions had attracted tremendous interest in many fields because of their great importance for both fundamental studies and practical applications. Herein zinc-aluminum layered double hydroxides (Zn-Al LDHs) films intercalated with nitrate anions on the magnesium alloy substrate were designed and fabricated via a facile hydrothermal crystallization method. In order to obtain better corrosion resistance, chloride and vanadate anions were intercalated into the LDHs interlayers via the anion-exchange reaction. X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electronic microscopy (SEM) were used to examine structure, composition and morphology of the Zn-Al-NO{sub 3} LDHs, Zn-Al-Cl LDHs and Zn-Al-VO{sub x} LDHs films. The corrosion resistance of the Zn-Al LDHs with different anion films was estimated by the electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization measurement. EIS and polarization curves measurements revealed that the magnesium alloy could be effectively protected by the Zn-Al-Cl LDHs and Zn-Al-VO{sub x} LDHs films due to the blocking effect of chloride anions and the control-release ability of vanadate anions.

  10. Feasibility of wavelength dispersive X-ray fluorescence spectrometry for a simplified analysis of bromine in water samples with the aid of a strong anion exchange disk

    International Nuclear Information System (INIS)

    An, Jinsung; Jung, Hyeyeon; Bae, Jo-Ri; Yoon, Hye-On; Seo, Jungju

    2014-01-01

    The feasibility of wavelength dispersive X-ray fluorescence spectrometry (WDXRF) for a simplified analysis of bromine (Br) in water samples with the aid of strong anion exchange (SAX) disk was assessed in this study. Dissolved Br in the water sample was pre-concentrated on the SAX disk and directly analyzed by WDXRF without an elution step. The SAX disk was capable of fully adsorbing both bromide (Br − ) and bromate (BrO 3 − ) on its surface owing to their anionic properties, regardless of the pH level of environmental samples. The SAX–WDXRF system was examined using calibration standards (i.e., SAX disks with specific amounts of Br retained; 1, 10, 50, 100 and 500 μg), and a determination coefficient of R 2 = 0.9999 was yielded. The system had a low detection limit for Br (limit of detection = 0.253 μg for Br on the SAX disk) with good reproducibility (relative standard error (RSE) = 4–7%). Spike and inter-comparison tests were performed to confirm the accuracy of the proposed SAX–WDXRF method. Both tests exhibited reasonable accuracy (RSE = 3–6%). The method is simple and easy, indicating a great possibility of application in various environmental sample types, especially for which a simplified analytical system for the determination of Br is urgently required. - Highlights: • Bromide and bromate were entirely retained on a strong anion exchange (SAX) disk. • The SAX disk was used to pre-concentrate dissolved Br species from water samples. • The SAX disk adsorbing dissolved Br was directly analyzed by WDXRF. • The accuracy of the SAX–WDXRF method was confirmed by spike and inter-comparison tests. • Rapid and sensitive Br analysis can be achieved using the proposed SAX–WDXRF method

  11. A New Hybrid BFOA-PSO Optimization Technique for Decoupling and Robust Control of Two-Coupled Distillation Column Process

    Directory of Open Access Journals (Sweden)

    Noha Abdelkarim

    2016-01-01

    Full Text Available The two-coupled distillation column process is a physically complicated system in many aspects. Specifically, the nested interrelationship between system inputs and outputs constitutes one of the significant challenges in system control design. Mostly, such a process is to be decoupled into several input/output pairings (loops, so that a single controller can be assigned for each loop. In the frame of this research, the Brain Emotional Learning Based Intelligent Controller (BELBIC forms the control structure for each decoupled loop. The paper’s main objective is to develop a parameterization technique for decoupling and control schemes, which ensures robust control behavior. In this regard, the novel optimization technique Bacterial Swarm Optimization (BSO is utilized for the minimization of summation of the integral time-weighted squared errors (ITSEs for all control loops. This optimization technique constitutes a hybrid between two techniques, which are the Particle Swarm and Bacterial Foraging algorithms. According to the simulation results, this hybridized technique ensures low mathematical burdens and high decoupling and control accuracy. Moreover, the behavior analysis of the proposed BELBIC shows a remarkable improvement in the time domain behavior and robustness over the conventional PID controller.

  12. Speciation of four selenium compounds using high performance liquid chromatography with on-line detection by inductively coupled plasma mass spectrometry or flame atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Pedersen, Gitte Alsing; Larsen, Erik Huusfeldt

    1997-01-01

    with an aqueous solution of 6 mmol L-1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass......An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination...... spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 sigma) achieved by the HPLC-FAAS system was 1 mg L-1 of selenium (100 mu L injections) for each of the four...

  13. Online micro-solid-phase extraction based on boronate affinity monolithic column coupled with high-performance liquid chromatography for the determination of monoamine neurotransmitters in human urine.

    Science.gov (United States)

    Yang, Xiaoting; Hu, Yufei; Li, Gongke

    2014-05-16

    Quantification of monoamine neurotransmitters is very important in diagnosing and monitoring of patients with neurological disorders. We developed an online analytical method to selectively determine urinary monoamine neurotransmitters, which coupled the boronate affinity monolithic column micro-solid-phase extraction with high-performance liquid chromatography (HPLC). The boronate affinity monolithic column was prepared by in situ polymerization of vinylphenylboronic acid (VPBA) and N,N'-methylenebisacrylamide (MBAA) in a stainless capillary column. The prepared monolithic column showed good permeability, high extraction selectivity and capacity. The column-to-column reproducibility was satisfactory and the enrichment factors were 17-243 for four monoamine neurotransmitters. Parameters that influence the online extraction efficiency, including pH of sample solution, flow rate of extraction and desorption, extraction volume and desorption volume were investigated. Under the optimized conditions, the developed method exhibited low limit of detection (0.06-0.80μg/L), good linearity (with R(2) between 0.9979 and 0.9993). The recoveries in urine samples were 81.0-105.5% for four monoamine neurotransmitters with intra- and inter-day RSDs of 2.1-8.2% and 3.7-10.6%, respectively. The online analytical method was sensitive, accurate, selective, reliable and applicable to analysis of trace monoamine neurotransmitters in human urine sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Separation and identification of uranium in the filtrates of diuranates by precipitation chromatography in the system anion exchange resin - hexacyanoferrate

    International Nuclear Information System (INIS)

    Seneda, Jose Antonio; Abrao, Alcidio

    1996-01-01

    The filtrates of sodium and ammonium diuranates usually have uranium at 5-20 mg/L concentration. In this work the separation of uranium (VI) in these filtrates was carried out, after adjusting the pH to 3.0 and percolating the solution on a strong-base anionic resin saturated with hexacyanoferrate (II). In this system the colored uranyl hexacyanoferrate (II) is precipitated in the top of the column and enables the visual observation of the uranium compound. The main operational factors of this process are studied, including the influent solution, formation of uranyl hexacyanoferrate (II) into the resin and uranium elution reagents. Results of the identification of uranium in the eluate and hexacyanoferrate (II)-resin system stability are discussed. (author)

  15. Column study of enhanced Cr(VI) removal and longevity by coupled abiotic and biotic processes using Fe0 and mixed anaerobic culture.

    Science.gov (United States)

    Zhong, Jiawei; Yin, Weizhao; Li, Yongtao; Li, Ping; Wu, Jinhua; Jiang, Gangbiao; Gu, Jingjing; Liang, Hao

    2017-10-01

    In this study, Fe 0 and mixed anaerobic culture were integrated in one column to investigate the coupled abiotic and biotic effects on hexa-valent chromium (Cr(VI)) removal and column longevity with an abiotic Fe 0 column in the control experiments. According to the breakthrough study, a slower Cr(VI) breakthrough rate of 0.19 cm/PV was observed in the biotic Fe 0 column whereas the value in the abiotic Fe 0 column was 0.30 cm/PV, resulting in 64% longer life-span and 62% higher Cr(VI) removal capacity in the biotic Fe 0 column than the abiotic one. The solid phase characterization by scanning electron microscopy (SEM), energy dispersive X-ray (EDX) and X-ray diffraction (XRD) confirmed that this enhancement was attributed to the higher consumption of iron and greater production of diverse reactive minerals (e.g., green rust, magnetite and lepidocrocite) induced by the synergistic interaction of Fe 0 and anaerobic culture, providing more reactive sites for Cr(VI) adsorption, reduction and co-precipitation. Furthermore, the decreasing breakthrough rates and growing iron corrosion along the biotic Fe 0 column demonstrated an inhomogeneous distribution of reactive zones in the column and its latter 3/5 section was considered to be the most reactive area for Cr(VI) removal. These results indicate that the inoculation of microorganisms in Fe 0 -based permeable reactive barriers will enable this technology a higher removal capacity and longer life-span for the remediation of Cr(VI)-contaminated groundwater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Coupling of column liquid chromatography and surface-enhanced resonance Raman spectroscopy via a thin-layer chromatographic plate.

    NARCIS (Netherlands)

    Coulter, S.K.; Gooijer, C.; Velthorst, N.H.; Brinkman, U.A.T.; Somsen, G.W.

    1997-01-01

    Surface-enhanced resonance Raman (SERR) spectroscopy was used to characterize compounds separated by column liquid chromatography (LC). Three percent of the effluent from a conventional-size LC column were immobilized on a moving thinlayer chromatography (TLC) plate using a spray-jet

  17. Application of a strong anion exchange material in electrostatic repulsion-hydrophilic interaction chromatography for selective enrichment of glycopeptides.

    Science.gov (United States)

    Cao, Liwei; Yu, Long; Guo, Zhimou; Li, Xiuling; Xue, Xinya; Liang, Xinmiao

    2013-07-19

    Glycoproteins are involved in various cellular activities, including inter- and extracellular signaling. However, glycopeptide signals are significantly suppressed by coeluting non-glycosylated peptides in mass spectrometry-based analysis. For detailed elucidation of the biological functions of glycoproteins, selective enrichment of glycopeptides from non-glycosylated peptides is crucial. In the present study, a SAX material, XCharge SAX, was used in a column in the ERLIC mode with the aim of specifically enriching glycopeptides. Enrichment conditions were initially optimized, and selectivity, glycosylation heterogeneity coverage and detection sensitivity of XCharge SAX were subsequently assessed. In the selectivity assessment, glycopeptides were effectively isolated from a peptide mixture (human serum immunoglobulin G (IgG) and human serum albumin digests) and a tryptic digest of human serum using XCharge SAX. In the evaluation of glycosylation heterogeneity coverage, five glycosites and eleven glycopeptides from horseradish peroxidase were identified after enrichment with XCharge SAX. In detection sensitivity assessment, glycopeptides within four orders of magnitude were identified after enrichment with XCharge SAX. In addition, volatile solvents were used in the loading and eluting buffers so that desalting was not necessary for ERLIC fractions. Our results collectively support the utility of XCharge SAX as a suitable chromatographic material for global glycosylation site analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled with LC-quadrupole/orbitrap high-resolution mass spectrometer.

    Science.gov (United States)

    Li, Hui; Ai, Lianfeng; Fan, Sufang; Wang, Yan; Sun, Dianxing

    2017-10-15

    A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS 2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R 2 ) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. High-performance liquid chromatography - Ultraviolet method for the determination of total specific migration of nine ultraviolet absorbers in food simulants based on 1,1,3,3-Tetramethylguanidine and organic phase anion exchange solid phase extraction to remove glyceride.

    Science.gov (United States)

    Wang, Jianling; Xiao, Xiaofeng; Chen, Tong; Liu, Tingfei; Tao, Huaming; He, Jun

    2016-06-17

    The glyceride in oil food simulant usually causes serious interferences to target analytes and leads to failure of the normal function of the RP-HPLC column. In this work, a convenient HPLC-UV method for the determination of the total specific migration of nine ultraviolet (UV) absorbers in food simulants was developed based on 1,1,3,3-tetramethylguanidine (TMG) and organic phase anion exchange (OPAE) SPE to efficiently remove glyceride in olive oil simulant. In contrast to the normal ion exchange carried out in an aqueous solution or aqueous phase environment, the OPAE SPE was performed in the organic phase environments, and the time-consuming and challenging extraction of the nine UV absorbers from vegetable oil with aqueous solution could be readily omitted. The method was proved to have good linearity (r≥0.99992), precision (intra-day RSD≤3.3%), and accuracy(91.0%≤recoveries≤107%); furthermore, the lower limit of quantifications (0.05-0.2mg/kg) in five types of food simulants(10% ethanol, 3% acetic acid, 20% ethanol, 50% ethanol and olive oil) was observed. The method was found to be well suited for quantitative determination of the total specific migration of the nine UV absorbers both in aqueous and vegetable oil simulant according to Commission Regulation (EU) No. 10/2011. Migration levels of the nine UV absorbers were determined in 31 plastic samples, and UV-24, UV-531, HHBP and UV-326 were frequently detected, especially in olive oil simulant for UV-326 in PE samples. In addition, the OPAE SPE procedure was also been applied to efficiently enrich or purify seven antioxidants in olive oil simulant. Results indicate that this procedure will have more extensive applications in the enriching or purification of the extremely weak acidic compounds with phenol hydroxyl group that are relatively stable in TMG n-hexane solution and that can be barely extracted from vegetable oil. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Ionic liquids monolithic columns for protein separation in capillary electrochromatography.

    Science.gov (United States)

    Liu, Cui-Cui; Deng, Qi-Liang; Fang, Guo-Zhen; Liu, Hui-Lin; Wu, Jian-Hua; Pan, Ming-Fei; Wang, Shuo

    2013-12-04

    A series of ionic liquids (ILs) monolithic capillary columns based on 1-vinyl-3-octylimidazolium (ViOcIm(+)) were prepared by two approaches ("one-pot" approach and "anion-exchange" approach). The effects of different anions (bromide, Br(-); tetrafluoroborate, BF4(-); hexafluorophosphate, PF6(-); and bis-trifluoromethanesulfonylimide, NTf2(-)) on chromatography performance of all the resulting columns were investigated systematically under capillary electrochromatography (CEC) mode. The results indicated that all these columns could generate a stable reversed electroosmotic flow (EOF) over a wide pH range from 2.0 to 12.0. For the columns prepared by "one-pot" approach, the EOF decreased in the order of ViOcIm(+)Br(-)>ViOcIm(+)BF4(-)>ViOcIm(+)PF6(-)>ViOcIm(+)NTf2(-) under the same CEC conditions; the ViOcIm(+)Br(-) based column exhibited highest column efficiencies for the test small molecules; the ViOcIm(+)NTf2(-) based column possessed the strongest retention for aromatic hydrocarbons; and baseline separation of four standard proteins was achieved on ViOcIm(+)NTf2(-) based column corresponding to the highest column efficiency of 479,000 N m(-1) for cytochrome c (Cyt c). These results indicated that the property of ILs based columns could be tuned successfully by changing anions, which gave these columns potential to separate both small molecules and macro biomolecules. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  1. Advanced treatment of textile dyeing secondary effluent using magnetic anion exchange resin and its effect on organic fouling in subsequent RO membrane.

    Science.gov (United States)

    Yang, Cheng; Li, Li; Shi, Jialu; Long, Chao; Li, Aimin

    2015-03-02

    Strict regulations are forcing dyeing factory to upgrade existing waste treatment system. In this study, advanced treatment of dyeing secondary effluent by magnetic anion exchange resin (NDMP) was investigated and compared with ultrafiltration (UF); NDMP as a pre-treatment of reverse osmosis (RO) was also studied. NDMP resin (20 mL/L) gave higher removal of dissolved organic carbon (DOC) (83.9%) and colority (94.9%) than UF with a cut-off of 10 kDa (only 48.6% and 44.1%, respectively), showing that NDMP treatment was effective to meet the stringent discharge limit of DOC and colority. Besides, NDMP resin (20 mL/L) as a pretreatment of RO increased the permeate flux by 12.5% and reduced irreversible membrane fouling by 6.6%, but UF pretreatment did not mitigate RO membrane fouling. The results of excitation-emission matrix fluorescence spectra and resin fractions showed that NDMP had more efficient removal than UF for transphilic acid and hydrophilic fraction, such as protein-like organic matters and soluble microbial products, which contributed to a significant proportion of RO membrane fouling. In sum, NDMP resin treatment not only gave effective removal of DOC and colority of dyeing secondary effluent, but exhibited some improvement for RO membrane flux and irreversible fouling. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Partially hydrolyzed guar gum characterization and sensitive quantification in food matrices by high performance anion exchange chromatography with pulsed amperometric detection--validation using accuracy profile.

    Science.gov (United States)

    Mercier, G; Campargue, C

    2012-11-02

    Interest concerning functional ingredients and especially dietary fibres has been growing in recent years. At the same time, the variety of ingredient accepted as dietary fibres and their mixing at low level in complex matrices have considerably complicated their quantitative analysis by approved AOAC methods. These reasons have led to the specific development of an innovative analytical method performed by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) to detect and quantify partially hydrolyzed guar gum (PHGG) in fruit preparation and dairy matrices. The analytical methodology was divided in two steps which could be deployed separately or in conjunction. The first, consists in a complete characterization of PHGG by size exclusion chromatography (SEC) with multi-angle light scattering and refractive index detection and HPAEC-PAD to determine its physico-chemical properties and galactomannans content, and the second step is the development of a new HPAEC-PAD method for PHGG direct quantification in complex matrices (dairy product). Validation in terms of detection and quantification limits, linearity of the analytical range, average accuracy (recovery, trueness) and average uncertainty were statistically carried out with accuracy profile. Overall, this new chromatographic method has considerably improved the possibility to quantify without fractionation treatment, low level of dietary fibres emerging from specific galactomannans, in complex matrices and many foodstuffs. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. The degradation of strong basic anion exchange resins and mixed-bed ion-exchange resins: Effect of degradation products on radionuclide speciation

    International Nuclear Information System (INIS)

    Loon, L.R. van; Hummel, W.

    1999-01-01

    The most important water-soluble products of the radiolytic degradation of anion exchange resins in a cementitious environment are ammonia and methylamines. These ligands do not form complexes with most radionuclides. Exceptions are Ni, Ag, and Pd, which form strong complexes with amines. Other degradation products of anion and mixed-bed ion-exchange resins are of no importance concerning the complexation of trivalent radionuclides. This is shown indirectly by adsorption experiments: The degradation products do not have a significant effect on the adsorption of Eu(III) on calcite. The effect of ammonia and methylamines on the complexation of Ni, Ag, and Pd is investigated by chemical modeling. For Ni and Ag, rather reliable predictions can be made using available thermodynamic data. In the case of Pd, large uncertainties are encountered due to unreliable data and gaps in the set of important species. The system Pd(II)-ammonia-water is explored in detail. Predominant species are inferred by chemical analogy, and their thermodynamic data are estimated. The uncertainty in these estimated and measured but unreliable data is bound by qualitative and quantitative chemical reasoning

  4. New inorganic (an)ion exchangers with a higher affinity for arsenate and a competitive removal capacity towards fluoride, bromate, bromide, selenate, selenite, arsenite and borate

    KAUST Repository

    Chubar, Natalia

    2011-12-01

    Highly selective materials and effective technologies are needed to meet the increasingly stronger drinking water standards for targeted ionic species. Inorganic ion exchangers based on individual and mixed-metal hydrous oxides (or mixed adsorbents that contain inorganic ion exchangers in their composition) are adsorptive materials that are capable of lowering the concentrations of anionic contaminants, such as H 2AsO 4 -, H 3AsO 3, F -, Br -, BrO 3 -, HSeO 4 -, HSeO 3 - and H 3BO 3, to 10 μg/L or less. To achieve a higher selectivity towards arsenate, a new ion exchanger based on Mg-Al hydrous oxides was developed by a novel, cost-effective and environmentally friendly synthesis method via a non-traditional (alkoxide-free) sol-gel approach. The exceptional adsorptive capacity of the Mg-Al hydrous oxides towards H 2AsO 4 - (up to 200 mg[As]/gdw) is due to the high affinity of this sorbent towards arsenate (steep equilibrium isotherms) and its fast adsorption kinetics. Because of the mesoporous (as determined by N 2 adsorption and SEM) and layered (as determined by XRD and FTIR) structure of the ion-exchange material as well as the abundance of anion exchange sites (as determined by XPS and potentiometric titration) on its surface the material demonstrated very competitive (or very high) removal capacity towards other targeted anions, including fluoride, bromide, bromate, selenate, selenite, and borate. © 2011 IWA Publishing.

  5. Durability and performance of polystyrene- b -poly(vinylbenzyl trimethylammonium) diblock copolymer and equivalent blend anion exchange membranes

    Energy Technology Data Exchange (ETDEWEB)

    Vandiver, Melissa A. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Caire, Benjamin R. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Poskin, Zach [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Li, Yifan [Department of Chemistry and Geochemistry, Colorado School of Mines, Golden Colorado 80401; Seifert, Sönke [X-Ray Science Division, Argonne National Laboratory, Argonne Illinois 60439; Knauss, Daniel M. [Department of Chemistry and Geochemistry, Colorado School of Mines, Golden Colorado 80401; Herring, Andrew M. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Liberatore, Matthew W. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401

    2014-11-01

    Anion exchange membranes (AEM) are solid polymer electrolytes that facilitate ion transport in fuel cells. In this study, a polystyrene-b-poly(vinylbenzyl trimethylammonium) diblock copolymer was evaluated as potential AEM and compared with the equivalent homopolymer blend. The diblock had a 92% conversion of reactive sites with an IEC of 1.72 ± 0.05 mmol g-1, while the blend had a 43% conversion for an IEC of 0.80 ± 0.03 mmol g-1. At 50°C and 95% relative humidity, the chloride conductivity of the diblock was higher, 24–33 mS cm-1, compared with the blend, 1–6 mS cm-1. The diblock displayed phase separation on the length scale of 100 nm, while the blend displayed microphase separation (~10 μm). Mechanical characterization of films from 40 to 90 microns thick found that elasticity and elongation decreased with the addition of cations to the films. At humidified conditions, water acted as a plasticizer to increase film elasticity and elongation. While the polystyrene-based diblock displayed sufficient ionic conductivity, the films' mechanical properties require improvement, i.e., greater elasticity and strength, before use in fuel cells. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41596.

  6. Analytical Method for Sugar Profile in Pet Food and Animal Feeds by High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection.

    Science.gov (United States)

    Ellingson, David J; Anderson, Phillip; Berg, Daniel P

    2016-01-01

    There is a need for a standardized, accurate, rugged, and consistent method to measure for sugars in pet foods and animal feeds. Many traditional standard sugar methods exist for other matrixes, but when applied in collaborative studies there was poor agreement and sources of error identified with those standard methods. The advancement in technology over the years has given us the ability to improve on these standard methods of analysis. A method is described here that addresses these common issues and was subjected to a single-laboratory validation to assess performance on a wide variety of pet foods and animal feeds. Of key importance to the method performance is the sample preparation before extraction, type of extraction solvent, postextraction cleanup, and, finally, optimized chromatography using high-performance anion exchange chromatography with pulsed amperometric detection. The results obtained from the validation demonstrate how typical issues seen with these matrixes can influence performance of sugar analysis. The results also demonstrate that this method is fit-for-purpose and can meet the challenges of sugar analysis in pet food and animal feeds to lay the foundation for a standardized method of analysis.

  7. La and Al co-doped CaMnO3 perovskite oxides: From interplay of surface properties to anion exchange membrane fuel cell performance

    Science.gov (United States)

    Dzara, Michael J.; Christ, Jason M.; Joghee, Prabhuram; Ngo, Chilan; Cadigan, Christopher A.; Bender, Guido; Richards, Ryan M.; O'Hayre, Ryan; Pylypenko, Svitlana

    2018-01-01

    This work reports the first account of perovskite oxide and carbon composite oxygen reduction reaction (ORR) catalysts integrated into anion exchange membrane fuel cells (AEMFCs). Perovskite oxides with a theoretical stoichiometry of Ca0.9La0.1Al0.1Mn0.9O3-δ are synthesized by an aerogel method and calcined at various temperatures, resulting in a set of materials with varied surface chemistry and surface area. Material composition is evaluated by X-ray diffraction, energy dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy. The perovskite oxide calcined at 800 °C shows the importance of balance between surface area, purity of the perovskite phase, and surface composition, resulting in the highest ORR mass activity when evaluated in rotating disk electrodes. Integration of this catalyst into AEMFCs reveals that the best AEMFC performance is obtained when using composites with 30:70 perovskite oxide:carbon composition. Doubling the loading leads to an increase in the power density from 30 to 76 mW cm-2. The AEMFC prepared with a composite based on perovskite oxide and N-carbon achieves a power density of 44 mW cm-2, demonstrating an ∼50% increase when compared to the highest performing composite with undoped carbon at the same loading.

  8. Recent Advances in Solid Catalysts Obtained by Metalloporphyrins Immobilization on Layered Anionic Exchangers: A Short Review and Some New Catalytic Results

    Directory of Open Access Journals (Sweden)

    Shirley Nakagaki

    2016-02-01

    Full Text Available Layered materials are a very interesting class of compounds obtained by stacking of two-dimensional layers along the basal axis. A remarkable property of these materials is their capacity to interact with a variety of chemical species, irrespective of their charge (neutral, cationic or anionic. These species can be grafted onto the surface of the layered materials or intercalated between the layers, to expand or contract the interlayer distance. Metalloporphyrins, which are typically soluble oxidation catalysts, are examples of molecules that can interact with layered materials. This work presents a short review of the studies involving metalloporphyrin immobilization on two different anionic exchangers, Layered Double Hydroxides (LDHs and Layered Hydroxide Salts (LHSs, published over the past year. After immobilization of anionic porphyrins, the resulting solids behave as reusable catalysts for heterogeneous oxidation processes. Although a large number of publications involving metalloporphyrin immobilization on LDHs exist, only a few papers have dealt with LHSs as supports, so metalloporphyrins immobilized on LHSs represent a new and promising research field. This work also describes new results on an anionic manganese porphyrin (MnP immobilized on Mg/Al-LDH solids with different nominal Mg/Al molar ratios (2:1, 3:1 and 4:1 and intercalated with different anions (CO32− or NO3−. The influence of the support composition on the MnP immobilization rates and the catalytic performance of the resulting solid in cyclooctene oxidation reactions will be reported.

  9. Impact of ozonation, anion exchange resin and UV/H2O2 pre-treatments to control fouling of ultrafiltration membrane for drinking water treatment.

    Science.gov (United States)

    Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Sarker, Dipok Chandra; Suja, Fatihah

    2017-06-01

    The effects of ozonation, anion exchange resin (AER) and UV/H 2 O 2 were investigated as a pre-treatment to control organic fouling (OF) of ultrafiltration membrane in the treatment of drinking water. It was found that high molecular weight (MW) organics such as protein and polysaccharide substances were majorly responsible for reversible fouling which contributed to 90% of total fouling. The decline rate increased with successive filtration cycles due to deposition of protein content over time. All pre-treatment could reduce the foulants of a Ultrafiltration membrane which contributed to the improvement in flux, and there was a greater improvement of flux by UV/H 2 O 2 (61%) than ozonation (43%) which in turn was greater than AER (23%) treatment. This was likely due to the effective removal/breakdown of high MW organic content. AER gave greater removal of biofouling potential components (such as biodegradable dissolved organic carbon and assimilable organic carbon contents) compared to UV/H 2 O 2 and ozonation treatment. Overall, this study demonstrated the potential of pre-treatments for reducing OF of ultrafiltration for the treatment of drinking water.

  10. Cross-Linked Quaternized Poly(styrene-b-(ethylene-co-butylene)-b-styrene) for Anion Exchange Membrane: Synthesis, Characterization and Properties.

    Science.gov (United States)

    Dai, Pei; Mo, Zhao-Hua; Xu, Ri-Wei; Zhang, Shu; Wu, Yi-Xian

    2016-08-10

    Poly(styrene-b-(ethylene-co-butylene)-b-styrene) triblock copolymer (SEBS) was selected for functionalization and cross-linking reaction to prepare the anion exchange membrane. The cross-linked quaternized SEBS (QSEBS-Cn) membranes were synthesized by simultaneous of quaternization and cross-linking of chloromethylated SEBS with α,ω-difunctional tertiary amines. The spacer groups of (-CH2-)n in diamines did affect the functionalization, micromorphology and properties of the resulting QSEBS-Cn membranes. The ionic conductivity of QSEBS-Cn membranes greatly increased and methanol resistance slightly decreased with increasing the length of spacer groups in the cross-linked structures from -(CH2)- to -(CH2)6-. Compared to the un-cross-linked QSEBS, the QSEBS-Cn membranes behaved much higher mechanical property, service temperature, chemical stability and thermal stability. Moreover, the hybrid composite membrane of QSEBS-C6 with 0.5% of graphene oxide could also be in situ prepared. This hybrid membrane had both relatively high ionic conductivity of 2.0 × 10(-2) S·cm(-1) and high selectivity of 7.6 × 10(4) S·s·cm(-3) at 60 °C due to its low methanol permeability.

  11. Improving the Energy Efficiency of Direct Formate Fuel Cells with a Pd/C-CeO2 Anode Catalyst and Anion Exchange Ionomer in the Catalyst Layer

    Directory of Open Access Journals (Sweden)

    Hamish Andrew Miller

    2018-02-01

    Full Text Available This article describes the development of a high power density Direct Formate Fuel Cell (DFFC fed with potassium formate (KCOOH. The membrane electrode assembly (MEA contains no platinum metal. The cathode catalyst is FeCo/C combined with a commercial anion exchange membrane (AEM. To enhance the power output and energy efficiency we have employed a nanostructured Pd/C-CeO2 anode catalyst. The activity for the formate oxidation reaction (FOR is enhanced when compared to a Pd/C catalyst with the same Pd loading. Fuel cell tests at 60 °C show a peak power density of almost 250 mW cm−2. The discharge energy (14 kJ, faradic efficiency (89% and energy efficiency (46% were determined for a single fuel charge (30 mL of 4 M KCOOH and 4 M KOH. Energy analysis demonstrates that removal of the expensive KOH electrolyte is essential for the future development of these devices. To compensate we apply for the first time a polymeric ionomer in the catalyst layer of the anode electrode. A homopolymer is synthesized by the radical polymerization of vinyl benzene chloride followed by amination with 1,4-diazabicyclo[2.2.2]octane (DABCO. The energy delivered, energy efficiency and fuel consumption efficiency of DFFCs fed with 4 M KCOOH are doubled with the use of the ionomer.

  12. Non Destructive Application of Radioactive Tracer Technique for Characterization of Industrial Grade Anion Exchange Resins Indio GS-300 and Indion-860

    International Nuclear Information System (INIS)

    Singare, P. U.

    2014-01-01

    The paper deals with the application of radio isotopic non-destructive technique in the characterization of two industrial grade anion exchange resins Indion GS-300 and Indion-860. For the characterization of the two resins, 131 I and 82 Br were used as tracer isotopes to trace the kinetics of iodide and bromide ion-isotopic exchange reactions. It was observed that the values of specific reaction rate (min -1 ), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log K d were calculated as 0.328, 0.577, 0.189 and 19.7 respectively for Indion GS-300 resin, which was higher than the respective values of 0.180, 0.386, 0.070 and 17.0 calculated for Indion-860 resins when measured under identical experimental conditions. Also at a constant temperature of 40.0 .deg. C, as the concentration of labeled iodide ion solution increases 0.001 M to 0.004 M, the percentage of iodide ions exchanged increases from 75.16 % to 78.36 % for Indion GS-300 resins, which was higher than the increases from 49.65 % to 52.36 % compared to that obtained for Indion-860 resins. The overall results indicate that under identical experimental conditions, Indion GS-300 resins show superior performance over Indion-860 resins

  13. Preparation and characterization of anion exchange resin decorated with magnetite nanoparticles for removal of p-toluic acid from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Davarpanah, Morteza, E-mail: Davarpanah.morteza@gmail.com; Ahmadpour, Ali; Rohani Bastami, Tahereh

    2015-02-01

    Polystyrene resin was covalently functionalized with diethanolamine and then decorated with magnetite nanoparticles by a novel and simple co-precipitation method using iron(II) sulfate as precursor. The products were characterized by Fourier transform infrared spectroscopy, elemental analysis, X-ray diffraction, Mössbauer spectroscopy, field-emission scanning electron microscopy and vibrating sample magnetometer. Adsorption of p-toluic acid (p-TA) onto magnetite-decorated polystyrene (MAG-PS) was studied and compared with that of diethanolamine-functionalized polystyrene and a commercial anion exchange resin. Results showed that the magnetite nanoparticles with an average size of 20.4 nm were successfully formed on the surface of polystyrene resin, and MAG-PS was exhibited high affinity for the removal of p-TA. - Highlights: • .Polystyrene resin was covalently functionalized with diethanolamine. • .The functionalized adsorbents were decorated with magnetite nanoparticles (∼20 nm). • .Proposed magnetization procedure was high-efficient and relatively simple. • .Magnetic adsorbent was presented high affinity for removal of p-toluic acid.

  14. Single particle electron microscopy analysis of the bovine anion exchanger 1 reveals a flexible linker connecting the cytoplasmic and membrane domains.

    Directory of Open Access Journals (Sweden)

    Jiansen Jiang

    Full Text Available Anion exchanger 1 (AE1 is the major erythrocyte membrane protein that mediates chloride/bicarbonate exchange across the erythrocyte membrane facilitating CO₂ transport by the blood, and anchors the plasma membrane to the spectrin-based cytoskeleton. This multi-protein cytoskeletal complex plays an important role in erythrocyte elasticity and membrane stability. An in-frame AE1 deletion of nine amino acids in the cytoplasmic domain in a proximity to the membrane domain results in a marked increase in membrane rigidity and ovalocytic red cells in the disease Southeast Asian Ovalocytosis (SAO. We hypothesized that AE1 has a flexible region connecting the cytoplasmic and membrane domains, which is partially deleted in SAO, thus causing the loss of erythrocyte elasticity. To explore this hypothesis, we developed a new non-denaturing method of AE1 purification from bovine erythrocyte membranes. A three-dimensional (3D structure of bovine AE1 at 2.4 nm resolution was obtained by negative staining electron microscopy, orthogonal tilt reconstruction and single particle analysis. The cytoplasmic and membrane domains are connected by two parallel linkers. Image classification demonstrated substantial flexibility in the linker region. We propose a mechanism whereby flexibility of the linker region plays a critical role in regulating red cell elasticity.

  15. Phenolphthalein-based Poly(arylene ether sulfone nitrile)s Multiblock Copolymers As Anion Exchange Membranes for Alkaline Fuel Cells.

    Science.gov (United States)

    Lai, Ao Nan; Wang, Li Sha; Lin, Chen Xiao; Zhuo, Yi Zhi; Zhang, Qiu Gen; Zhu, Ai Mei; Liu, Qing Lin

    2015-04-22

    A series of phenolphthalein-based poly(arylene ether sulfone nitrile)s (PESN) multiblock copolymers containing 1-methylimidazole groups (ImPESN) were synthesized to prepare anion exchange membranes (AEMs) for alkaline fuel cells. The ion groups were introduced selectively and densely on the unit of phenolphthalein as the hydrophilic segments, allowing for the formation of ion clusters. Strong polar nitrile groups were introduced into the hydrophobic segments with the intention of improving the dimensional stability of the AEMs. A well-controlled multiblock structure was responsible for the well-defined hydrophobic/hydrophilic phase separation and interconnected ion-transport channels, as confirmed by atomic force microscopy and small angle X-ray scattering. The ImPESN membranes with low swelling showed a relatively high water uptake, high hydroxide ion conductivity together with good mechanical, thermal and alkaline stability. The ionic conductivity of the membranes was in the range of 3.85-14.67×10(-2) S·cm(-1) from 30 to 80 °C. Moreover, a single H2/O2 fuel cell with the ImPESN membrane showed an open circuit voltage of 0.92 V and a maximum power density of 66.4 mW cm(-2) at 60 °C.

  16. Measurement of elemental speciation by liquid chromatography -- inductively coupled plasma mass spectrometry (LC-ICP-MS) with the direct injection nebulizer (DIN)

    Energy Technology Data Exchange (ETDEWEB)

    Shum, Sam [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    This thesis is divided into 4 parts: elemental speciation, speciation of mercury and lead compounds by microbore column LC-ICP-MS with direct injection nebulization, spatially resolved measurements of size and velocity distributions of aerosol droplets from a direct injection nebulizer, and elemental speciation by anion exchange and size exclusion chromatography with detection by ICP-MS with direct injection nebulization.

  17. Evaluation of column length and particle size effect on the untargeted profiling of a phytochemical mixture by using UHPLC coupled to high-resolution mass spectrometry.

    Science.gov (United States)

    Zenezini Chiozzi, Riccardo; Capriotti, Anna Laura; Cavaliere, Chiara; Ferraris, Francesca; La Barbera, Giorgia; Piovesana, Susy; Laganà, Aldo

    2017-06-01

    Liquid chromatography coupled to high-resolution mass spectrometry is the technique of choice for the untargeted profiling of food matrices. Despite the high potential of high-resolution mass spectrometry, when dealing with complex mixtures, an efficient separation technique is also needed. The novel core-shell chromatographic columns packed with sub-2 μm sized particles are claimed to show very good resolution. However, the analytes retention can be significantly altered when working under ultra-high performance chromatographic conditions. In this work, an evaluation of four chromatographic systems, with either a single or two in-series Kinetex™ C 18 columns, either packed with 2.6 or 1.7 μm particles, is presented for the targeted analysis of a standard mixture and the untargeted analysis of a strawberry extract. An ultra-high performance chromatographic system coupled via an electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer was used. From the extensive comparison, a surprising result was obtained, namely, that the system identifying the largest number of features was the one with two in-series connected columns with the larger particle size. The inconsistency among the theoretical assumptions and the applicative findings points out the importance of an extensive chromatographic evaluation for the comprehensive untargeted profiling of complex real samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Survey of inorganic arsenic in marine animals and marine certified reference materials by anion exchange high-performance liquid chromatography-inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Sloth, Jens Jørgen; Larsen, Erik Huusfeldt; Julshamn, Kåre

    2005-01-01

    , bivalves, and marine mammals as well as a range of marine certified reference materials, and the results were compared to values published in the literature. For fish and marine mammals, the results were in most cases below the limit of detection. For other sample types, inorganic arsenic concentrations up...

  19. Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Montone, Carmela Maria; Piovesana, Susy; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2018-03-01

    The untargeted profiling is a promising approach for the characterization of secondary metabolites in biological matrices. Thanks to the recent rapid development of high-resolution mass spectrometry (HRMS) instrumentations, the number of applications by untargeted approaches for biological samples profiling has widely increased in the recent years. Despite the high potentialities of HRMS, however, a major issue in natural products analysis often arises in the upstream process of compounds separation. A separation technique is necessary to avoid phenomena such as signal suppression, and it is especially needed in the presence of isomeric metabolites, which are otherwise indistinguishable. Glucosinolates (GLSs), a group of secondary metabolites widely distributed among plants, resulted to be associated to the prevention of some serious diseases, such as cancer. This led to the development of several methods for the analysis of GLSs in vegetables tissues. The issue of GLSs chromatographic separation has been widely studied in the past because of the difficulty in the analysis of this highly polar and variable class of compounds. Several alternatives to reversed phase (RP) chromatography, sometimes not compatible with the coupling of liquid chromatography with mass spectrometry, have been tested for the analysis of intact GLSs. However, the availability of new stationary phases, in the last years, could allow the re-evaluation of RP chromatography for the analysis of intact GLSs. In this work, a thorough evaluation of four RP chromatographic columns for the analysis of GLSs in cauliflower (Brassica oleracea L. var. botrytis) extracts by an ultra-high performance liquid chromatographic system coupled via electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer is presented. The columns tested were the following: one column Luna Omega polar C 18 , one column Kinetex Biphenyl, one column Kinetex core-shell XB-C 18 , two columns Kinetex core-shell XB-C 18

  20. A SLC4-like anion exchanger from renal tubules of the mosquito (Aedes aegypti): evidence for a novel role of stellate cells in diuretic fluid secretion.

    Science.gov (United States)

    Piermarini, Peter M; Grogan, Laura F; Lau, Kenneth; Wang, Li; Beyenbach, Klaus W

    2010-03-01

    Transepithelial fluid secretion across the renal (Malpighian) tubule epithelium of the mosquito (Aedes aegypti) is energized by the vacuolar-type (V-type) H(+)-ATPase and not the Na(+)-K(+)-ATPase. Located at the apical membrane of principal cells, the V-type H(+)-ATPase translocates protons from the cytoplasm to the tubule lumen. Secreted protons are likely to derive from metabolic H(2)CO(3), which raises questions about the handling of HCO(3)(-) by principal cells. Accordingly, we tested the hypothesis that a Cl/HCO(3) anion exchanger (AE) related to the solute-linked carrier 4 (SLC4) superfamily mediates the extrusion of HCO(3)(-) across the basal membrane of principal cells. We began by cloning from Aedes Malpighian tubules a full-length cDNA encoding an SLC4-like AE, termed AeAE. When expressed heterologously in Xenopus oocytes, AeAE is both N- and O-glycosylated and mediates Na(+)-independent intracellular pH changes that are sensitive to extracellular Cl(-) concentration and to DIDS. In Aedes Malpighian tubules, AeAE is expressed as two distinct forms: one is O-glycosylated, and the other is N-glycosylated. Significantly, AeAE immunoreactivity localizes to the basal regions of stellate cells but not principal cells. Concentrations of DIDS that inhibit AeAE activity in Xenopus oocytes have no effects on the unstimulated rates of fluid secretion mediated by Malpighian tubules as measured by the Ramsay assay. However, in Malpighian tubules stimulated with kinin or calcitonin-like diuretic peptides, DIDS reduces the diuretic rates of fluid secretion to basal levels. In conclusion, Aedes Malpighian tubules express AeAE in the basal region of stellate cells, where this transporter may participate in producing diuretic rates of transepithelial fluid secretion.

  1. Cholesterol concentrations in lipoprotein fractions separated by anion-exchange-high-performance liquid chromatography in healthy dogs and dogs with hypercholesterolemia.

    Science.gov (United States)

    Oda, Hitomi; Mori, Akihiro; Hirowatari, Yuji; Takoura, Toshie; Manita, Daisuke; Takahashi, Tomoya; Shono, Saori; Onozawa, Eri; Mizutani, Hisashi; Miki, Yohei; Itabashi, Yukiko; Sako, Toshinori

    2017-10-01

    Anion-exchange (AEX)-high-performance liquid chromatography (HPLC) for measurement of cholesterol can be used to separate serum lipoproteins (high-density lipoprotein (HDL); low-density lipoprotein (LDL); intermediate-density lipoprotein (IDL); very-low-density lipoprotein (VLDL)) in humans. However, AEX-HPLC has not been applied in veterinary practice. We had three objectives: (i) the validation of AEX-HPLC methods including the correlation of serum cholesterol concentration in lipoprotein fraction measured by AEX-HPLC and gel permeation-HPLC (GP-HPLC) in healthy dogs and those with hypercholesterolemia was investigated; (ii) the reference intervals of lipoprotein fractions measured by AEX-HPLC from healthy dogs (n=40) was established; (iii) lipoprotein fractions from the serum of healthy dogs (n=12) and dogs with hypercholesterolemia (n=23) were compared. Analytic reproducibility and precision of AEX-HPLC were acceptable. Positive correlation between serum concentrations of total cholesterol (Total-Chol), HDL cholesterol (HDL-Chol), LDL cholesterol (LDL-Chol)+IDL cholesterol (IDL-Chol), and VLDL cholesterol (VLDL-Chol) was noted for AEX-HPLC and GP-HPLC in healthy dogs and dogs with hypercholesterolemia. Reference intervals measured by AEX-HPLC for serum concentrations of Total-Chol, HDL-Chol, and LDL-Chol were determined to be 2.97-9.32, 2.79-6.57, 0.16-3.28mmol/L (2.5-97.5% interval), respectively. Furthermore, there was significant difference in lipoprotein profiles between healthy and dogs with hypercholesterolemia. These results suggest that AEX-HPLC can be used to evaluate lipoprotein profiles in dogs and could be a new useful indicator of hyperlipidemia in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Stability of a Cu0.7Co2.3O4 electrode during the oxygen evolution reaction for alkaline anion-exchange membrane water electrolysis

    Science.gov (United States)

    Kang, Kyoung Eun; Kim, Chi Ho; Lee, Myung Sup; Jung, Chang Wook; Kim, Yang Do; Lee, Jae Ho

    2018-01-01

    The electrode materials for oxygen evolution, especially non-platinum group metal oxides, have attracted increasing attention. Among the spinel-type transition metal oxides, Cu0.7Co2.3O4 powders were evaluated as a potential replacement for expensive dimensionally stabilized anode materials. Cu0.7Co2.3O4 powder for use as an electrode material for oxygen evolution in an alkaline anion-exchange membrane water electrolyzer was prepared using a thermal decomposition method. The Cu0.7Co2.3O4 powders heat-treated at 250 °C exhibited the same X-ray diffraction patterns without any secondary phases as the Co3O4 spinel structure did. The Cu0.7Co2.3O4 powders heat-treated at 250 °C for 30 minutes showed the smallest mean particle size of approximately 376 nm with the powders having a homogeneous shape and size distribution. The fine powders with a relatively homogeneous size distribution showed a higher current density during the oxygen evolution reaction. The lifetime of the Cu0.7Co2.3O4 electrode was relatively long at a low current density, but was quickly shortened due to physical detachment of the Cu0.7Co2.3O4 powders as the current density was increased. This study showed that the efficiency and the stability of Cu0.7Co2.3O4 powders during the oxygen evolution reaction were related directly to the active electrode area.

  3. Role of adaptor proteins and clathrin in the trafficking of human kidney anion exchanger 1 (kAE1) to the cell surface.

    Science.gov (United States)

    Junking, Mutita; Sawasdee, Nunghathai; Duangtum, Natapol; Cheunsuchon, Boonyarit; Limjindaporn, Thawornchai; Yenchitsomanus, Pa-thai

    2014-07-01

    Kidney anion exchanger 1 (kAE1) plays an important role in acid-base homeostasis by mediating chloride/bicarbornate (Cl-/HCO3-) exchange at the basolateral membrane of α-intercalated cells in the distal nephron. Impaired intracellular trafficking of kAE1 caused by mutations of SLC4A1 encoding kAE1 results in kidney disease - distal renal tubular acidosis (dRTA). However, it is not known how the intracellular sorting and trafficking of kAE1 from trans-Golgi network (TGN) to the basolateral membrane occurs. Here, we studied the role of basolateral-related sorting proteins, including the mu1 subunit of adaptor protein (AP) complexes, clathrin and protein kinase D, on kAE1 trafficking in polarized and non-polarized kidney cells. By using RNA interference, co-immunoprecipitation, yellow fluorescent protein-based protein fragment complementation assays and immunofluorescence staining, we demonstrated that AP-1 mu1A, AP-3 mu1, AP-4 mu1 and clathrin (but not AP-1 mu1B, PKD1 or PKD2) play crucial roles in intracellular sorting and trafficking of kAE1. We also demonstrated colocalization of kAE1 and basolateral-related sorting proteins in human kidney tissues by double immunofluorescence staining. These findings indicate that AP-1 mu1A, AP-3 mu1, AP-4 mu1 and clathrin are required for kAE1 sorting and trafficking from TGN to the basolateral membrane of acid-secreting α-intercalated cells. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Structure and protein adsorption mechanisms of clean and fouled tentacle-type anion exchangers used in a monoclonal antibody polishing step.

    Science.gov (United States)

    Corbett, Rachel; Carta, Giorgio; Iskra, Timothy; Gallo, Christopher; Godavarti, Ranga; Salm, Jeffrey R

    2013-02-22

    The properties of Fractogel(®) EMD TMAE HiCap (M), a tentacle-type anion exchange resin used for a polishing step in a monoclonal antibody (mAb) purification process, were investigated for both virgin and used samples to determine the influence of process related fouling. Inverse size exclusion chromatography indicated a bimodal distribution of pore sizes consisting mostly of small pores, 4-5 nm in radius and likely associated with the grafted tentacles. Similar results were obtained for resin samples fouled by process use, indicating that the core structure of these particles is unchanged. Transmission electron micrographs showed that the resin backbone matrix has a microgranular structure. However, a dense skin layer, 0.2-0.5 μm thick, was also seen at the exterior surface of the fouled particles. The binding capacity attained for BSA after 90 min of contact was 165 ± 4 mg/mL for both virgin and fouled samples, close to the equilibrium capacity of 178 ± 2 mg/mL attained after 24h. On the other hand, the capacities attained at 90 min for the much larger thyroglobulin were only 90 ± 4 and 25 ± 2 mg/mL, respectively, for virgin and fouled samples. The BSA adsorption kinetics was also slower for the fouled resin, but much larger kinetic differences between virgin and fouled resin were seen for thyroglobulin. Based on the shape of intraparticle protein concentration profiles determined by confocal laser scanning microscopy (CLSM), the protein transport mechanism is consistent with solid diffusion for both virgin and fouled resin samples and proteins. However, transport is hindered by the foulant layer to a much greater extent for thyroglobulin as a result of its larger size. Additional measurements indicated that the foulant layer is consistent with mAb aggregates irreversibly bound at the particle exterior surface. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Looking for new hybrid polymer fillers: synthesis of nanosized α-type Zr(IV) organophosphonates through an unconventional topotactic anion exchange reaction.

    Science.gov (United States)

    Pica, Monica; Donnadio, Anna; Troni, Elisabetta; Capitani, Donatella; Casciola, Mario

    2013-07-01

    Gels of α-type zirconium(IV) phosphate alkylphosphonates, ZP(Cn)x, were prepared by reacting, at room temperature, propanol intercalated nanosized α-zirconium phosphate (α-ZrP) with propanol solutions of alkylphosphonic acids (H2Cn, n = number of carbon atoms in the alkyl chain = 4, 5, 6), with (H2Cn/Zr) molar ratios in the range 0.4-4.0. (31)P MAS NMR showed the presence of resonances due to the phosphate and phosphonate groups bonded to the Zr atoms mainly by three oxygen atoms, as in the α-type layer. The composition of the ZP(Cn)x materials, obtained by thermogravimetric analysis, ranges from x ≈ 0.2 to x ≈ 1.1. On the basis of the NMR data and of the analysis of the X-ray patterns of gels and powders, it is inferred that the ZP(Cn)x compounds have an α-type layered structure and that the reaction between α-ZrP and H2Cn is a topotactic anion exchange process. The evolution of the X-ray patterns during propanol deintercalation is consistent with a random distribution of the alkylphosphonate groups on the α-type layers which gives rise to porous pathways in the interlayer region. To test the possibility of using ZP(Cn)x as mechanical reinforcement of a polymer matrix, a starch membrane filled with 5 wt % ZP(C6)0.54 was prepared and characterized by stress-strain mechanical tests. Besides an excellent flexibility, this membrane exhibited a proportional increase of the Young's modulus by 230% in comparison with neat starch.

  6. Separation of cannabinoids on three different mixed-mode columns containing carbon/nanodiamond/amine-polymer superficially porous particles.

    Science.gov (United States)

    Hung, Chuan-Hsi; Zukowski, Janusz; Jensen, David S; Miles, Andrew J; Sulak, Clayton; Dadson, Andrew E; Linford, Matthew R

    2015-09-01

    Three mixed-mode high-performance liquid chromatography columns packed with superficially porous carbon/nanodiamond/amine-polymer particles were used to separate mixtures of cannabinoids. Columns evaluated included: (i) reversed phase (C18 ), weak anion exchange, 4.6 × 33 mm, 3.6 μm, and 4.6 × 100 mm, 3.6 μm, (ii) reversed phase, strong anion exchange (quaternary amine), 4.6×33 mm, 3.6 μm, and (iii) hydrophilic interaction liquid chromatography, 4.6 × 150 mm, 3.6 μm. Different selectivities were achieved under various mobile phase and stationary phase conditions. Efficiencies and peak capacities were as high as 54 000 N/m and 56, respectively. The reversed phase mixed-mode column (C18 ) retained tetrahydrocannabinolic acid strongly under acidic conditions and weakly under basic conditions. Tetrahydrocannabinolic acid was retained strongly on the reversed phase, strong anion exchange mixed-mode column under basic polar organic mobile phase conditions. The hydrophilic interaction liquid chromatography column retained polar cannabinoids better than the (more) neutral ones under basic conditions. A longer reversed phase (C18 ) mixed-mode column (4.6 × 100 mm) showed better resolution for analytes (and a contaminant) than a shorter column. Fast separations were achieved in less than 5 min and sometimes 2 min. A real world sample (bubble hash extract) was also analyzed by gradient elution. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Novel room-temperature spin-valve-like magnetoresistance in magnetically coupled nano-column Fe3O4/Ni heterostructure.

    Science.gov (United States)

    Xiao, Wen; Song, Wendong; Herng, Tun Seng; Qin, Qing; Yang, Yong; Zheng, Ming; Hong, Xiaoliang; Feng, Yuan Ping; Ding, Jun

    2016-08-25

    Herein, we design a room-temperature spin-valve-like magnetoresistance in a nano-column Fe3O4/Ni heterostructure without using a non-magnetic spacer or pinning layer. An Fe3O4 nano-column film is self-assembled on a Ni underlayer by the thermal decomposition method. The wet-chemical self-assembly is facile, economical and scalable. The magnetoresistance (MR) response of the Ni underlayer in the heterostructure under positive and negative out-of-plane magnetic fields differ by ∼0.25 at room temperature and ∼0.43 at 100 K. We attribute the spin-valve-like magnetoresistance to the unidirectional magnetic anisotropy of the Ni underlayer when being magnetically coupled by the Fe3O4 nano-column film. The out-of-plane negative-field magnetization is higher than the positive-field magnetization, affirming the unidirectional magnetic anisotropy of the Fe3O4/Ni heterostructure. Temperature-dependent magnetic and resistivity studies illustrate a close correlation between the magnetization transition of Fe3O4 and resistivity transition of Ni and prove a magnetic coupling between the Fe3O4 and Ni. First-principles calculations reveal that the Fe3O4/Ni model under a negative magnetic field is energetically more stable than that under a positive magnetic field. Furthermore, partial density of states (PDOS) analysis demonstrates the unidirectional magnetic anisotropy of the Ni 3d orbital. This is induced by the strong ferromagnetic coupling between Fe3O4 and Ni via oxygen-mediated Fe 3d-O 2p-Ni 3d hybridizations.

  8. Separation of nucleobases, nucleosides, and nucleotides using two zwitterionic silica-based monolithic capillary columns coupled with tandem mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Haapala, M.; Planeta, Josef; Hyötyläinen, T.; Kostiainen, R.; Wiedmer, S. K.

    2014-01-01

    Roč. 1373, Dec (2014), s. 90-96 ISSN 0021-9673 R&D Projects: GA MV VG20112015021; GA ČR(CZ) GAP106/12/0522 Institutional support: RVO:68081715 Keywords : HILIC separation * ESI–MS * Monolithic silica column Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 4.169, year: 2014 http://hdl.handle.net/11104/0242051

  9. Comparison between an anionic exchanger of chitosan quaternary ammonium salt and a commercial exchanger in the extraction of available phosphorus in soils; Comparacao entre um trocador anionico de sal de amonio quaternario de quitosana e um trocador comercial na extracao de fosforo disponivel em solos

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves Junior, Affonso Celso; Nacke, Herbert, E-mail: herbertnacke@hotmail.co [Universidade Estadual do Oeste do Parana, Marechal Rondon, PR (Brazil). Centro de Ciencias Agrarias; Favere, Valfredo Tadeu de [Universidade Federal de Santa Catarina (DQ/UFSC), RS (Brazil). Dept. de Quimica; Gomes, Gilmar Divino [Faculdade de Tecnologia Internacional, Curitiba, PR (Brazil)

    2010-07-01

    The present work aimed modify chemically the chitosan (QTS) surface to obtain a reticulate chitosan quaternary ammonium salt (SAQQR), and compare this anionic exchanger with an commercial ion exchanger in the extraction of available phosphorus in soils. The results showed that the two exchangers are identical, extracting similar and proportional quantities of available phosphorus in the studied soils, and the anionic exchanger of SAQQR provides a high chemical stability, not affected by the pH difference of soils. (author)

  10. Acylhydrazone bond dynamic covalent polymer gel monolithic column online coupling to high-performance liquid chromatography for analysis of sulfonamides and fluorescent whitening agents in food.

    Science.gov (United States)

    Zhang, Chengjiang; Luo, Xialin; Wei, Tianfu; Hu, Yufei; Li, Gongke; Zhang, Zhuomin

    2017-10-13

    A new dynamic covalent polymer (DCP) gel was well designed and constructed based on imine chemistry. Polycondensation of 4,4'-biphenyldicarboxaldehyde and 1,3,5-benzenetricarbohydrazide via Schiff-base reaction resulted in an acylhydrazone bond gel (AB-gel) DCP. AB-gel DCP had three-dimensional network of interconnected nanoparticles with hierarchically porous structure. AB-gel DCP was successfully fabricated as a monolithic column by an in-situ chemical bonding method for online enrichment and separation purpose with excellent permeability. AB-gel DCP based monolithic column showed remarkable adsorption affinity towards target analytes including sulfonamides (SAs) and fluorescent whitening agents (FWAs) due to its strong π-π affinity, hydrophobic effect and hydrogen bonding interaction. Then, AB-gel DCP based monolithic column was applied for online separation and analysis of trace SAs and FWAs in food samples coupled with high-performance liquid chromatography (HPLC). Sulfathiazole (ST) and sulfadimidine (SM2) in one positive weever sample were actually found and determined with concentrations of 273.8 and 286.3μg/kg, respectively. 2,5-Bis(5-tert-butyl-2-benzoxazolyl) thiophene (FWA184) was actually quantified in one tea infusion sample with the concentration of 268.5ng/L. The spiked experiments suggested the good recoveries in range of 74.5-110% for SAs in weever and shrimp samples with relative standard deviations (RSDs) less than 9.7% and in range of 74.0-113% for FWAs in milk and tea infusion samples with RSDs less than 9.0%. AB-gel DCP monolithic column was proved to be a promising sample preparation medium for online separation and analysis of trace analytes in food samples with complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, S. E.; Freese, R.; Cornett, Claus

    2000-01-01

    by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...

  12. Basolateral chloride loading by the anion exchanger type 2: role in fluid secretion by the human airway epithelial cell line Calu-3.

    Science.gov (United States)

    Huang, Junwei; Shan, Jiajie; Kim, Dusik; Liao, Jie; Evagelidis, Alexandra; Alper, Seth L; Hanrahan, John W

    2012-11-01

    Anion exchanger type 2 (AE2 or SLC4A2) is an electroneutral Cl(-)/HCO(3)(-) exchanger expressed at the basolateral membrane of many epithelia. It is thought to participate in fluid secretion by airway epithelia. However, the role of AE2 in fluid secretion remains uncertain, due to the lack of specific pharmacological inhibitors, and because it is electrically silent and therefore does not contribute directly to short-circuit current (I(sc)). We have studied the role of AE2 in Cl(-) and fluid secretion by the airway epithelial cell line Calu-3. After confirming expression of its mRNA and protein, a knock-down cell line called AE2-KD was generated by lentivirus-mediated RNA interference in which AE2 mRNA and protein levels were reduced 90%. Suppressing AE2 increased the expression of the cystic fibrosis transmembrane conductance regulator (CFTR) by ∼70% without affecting the levels of NKCC1 (Na(+)-K(+)-2Cl(-) cotransporter) or NBCe1 (Na(+)-nHCO(3)(-) cotransporter). cAMP agonists stimulated fluid secretion by parental Calu-3 and scrambled shRNA cells >6.5-fold. In AE2-KD cells this response was reduced by ∼70%, and the secreted fluid exhibited elevated pH and [HCO(3)(-)] as compared with the control lines. Unstimulated equivalent short-circuit current (I(eq)) was elevated in AE2-KD cells, but the incremental response to forskolin was unaffected. The modest bumetanide-induced reductions in both I(eq) and fluid secretion were more pronounced in AE2-KD cells. Basolateral Cl(-)/HCO(3)(-) exchange measured by basolateral pH-stat in cells with permeabilized apical membranes was abolished in AE2-KD monolayers, and the intracellular alkalinization resulting from basolateral Cl(-) removal was reduced by ∼80% in AE2-KD cells. These results identify AE2 as a major pathway for basolateral Cl(-) loading during cAMP-stimulated secretion of Cl(-) and fluid by Calu-3 cells, and help explain the large bumetanide-insensitive component of fluid secretion reported previously in

  13. A simple and reliable anion-exchange resin method for sulfate extraction and purification suitable for multiple O- and S-isotope measurements.

    Science.gov (United States)

    Le Gendre, Erwann; Martin, Erwan; Villemant, Benoit; Cartigny, Pierre; Assayag, Nelly

    2017-01-15

    The O- and S-isotope compositions of sulfates can be used as key tracers of the fate and sink of sulfate in both terrestrial and extra-terrestrial environments. However, their application remains limited in those geological systems where sulfate occurs in low concentrations. Here we present a simple and reliable method to extract, purify and concentrate sulfate from natural samples. The method allows us to take into account the separation of nitrate, which is known to be an issue in O-isotope analysis. The separation and concentration of sulfate from other anions in any aqueous solution are performed within a few hours via anion-exchange resin. The possible O- (δ 18 O and Δ 17 O) and S- (δ 34 S, Δ 33 S and Δ 36 S) isotope exchanges, fractionations and/or contaminations are for the first time monitored during the whole procedure using initial O- and S-mass-dependent and mass-independent sulfate solutions. After elution in HCl, pure sulfate is fully retrieved and precipitated into BaSO 4 , which is suitable for O- and S-isotopic measurements using established techniques. The analysis of retrieved barite presents no variation within 2σ uncertainties: ±0.5‰ and ±0.1‰ in O- (δ 18 O, Δ 17 O) and ±0.2‰, ±0.02‰ and ±0.09‰ in S- (δ 34 S, Δ 33 S and Δ 36 S) isotope ratios, respectively. This study shows that the resin method for sulfate extraction and purification, in addition to being cheap, simple and quick, is applicable for the measurements of all O- and S-isotopic ratios in sulfates (including the Δ 17 O, Δ 33 S and Δ 36 S values). Therefore, this method can be easily used for a high range of natural samples in which sulfate occurs in low concentration including aerosols, ice cores, sediments, volcanic deposits, (paleo)soils and rainwater, and thus it can be a key to our understanding of the sulfur cycle on Earth. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Human kidney anion exchanger 1 interacts with adaptor-related protein complex 1 μ1A (AP-1 mu1A)

    International Nuclear Information System (INIS)

    Sawasdee, Nunghathai; Junking, Mutita; Ngaojanlar, Piengpaga; Sukomon, Nattakan; Ungsupravate, Duangporn; Limjindaporn, Thawornchai; Akkarapatumwong, Varaporn; Noisakran, Sansanee; Yenchitsomanus, Pa-thai

    2010-01-01

    Research highlights: → Trafficking defect of kAE1 is a cause of dRTA but trafficking pathway of kAE1 has not been clearly described. → Adaptor-related protein complex 1 μ1A (AP-1 mu1A) was firstly reported to interact with kAE1. → The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. → AP-1 mu1A knockdown showed a marked reduction of kAE1 on the cell membrane and its accumulation in endoplasmic reticulum. → AP-1 mu1A has a critical role in kAE1 trafficking to the plasma membrane. -- Abstract: Kidney anion exchanger 1 (kAE1) mediates chloride (Cl - ) and bicarbonate (HCO 3 - ) exchange at the basolateral membrane of kidney α-intercalated cells. Impaired trafficking of kAE1 leads to defect of the Cl - /HCO 3 - exchange at the basolateral membrane and failure of proton (H + ) secretion at the apical membrane, causing a kidney disease - distal renal tubular acidosis (dRTA). To gain a better insight into kAE1 trafficking, we searched for proteins physically interacting with the C-terminal region of kAE1 (Ct-kAE1), which contains motifs crucial for intracellular trafficking, by a yeast two-hybrid (Y2H) system. An adaptor-related protein complex 1 μ1A (AP-1 mu1A) subunit was found to interact with Ct-kAE1. The interaction between either Ct-kAE1 or full-length kAE1 and AP-1 mu1A were confirmed in human embryonic kidney (HEK) 293T by co-immunoprecipitation, affinity co-purification, co-localization, yellow fluorescent protein (YFP)-based protein fragment complementation assay (PCA) and GST pull-down assay. The interacting site for AP-1 mu1A on Ct-kAE1 was found to be Y904DEV907, a subset of YXXO motif. Interestingly, suppression of endogenous AP-1 mu1A in HEK 293T by small interfering RNA (siRNA) decreased membrane localization of kAE1 and increased its intracellular accumulation, suggesting for the first time that AP-1 mu1A is involved in the kAE1 trafficking of kidney α-intercalated cells.

  15. Determination of rare earth elements in seawater by inductively coupled plasma mass spectrometry with off-line column preconcentration using 2,6-diacetylpyridine functionalized Amberlite XAD-4

    International Nuclear Information System (INIS)

    Karadas, Cennet; Kara, Derya; Fisher, Andrew

    2011-01-01

    An off-line column preconcentration technique using a micro-column of 2,6 diacetylpyridine functionalized Amberlite XAD-4 with inductively coupled plasma mass spectrometry (ICP-MS) as a means of detection has been developed. The aim of the method was to determine rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) in seawater. Sample solutions (2-10 mL) were passed through the column which was then washed with ultra-pure water to remove residual matrix. The adsorbed cations on the resin were eluted by using 2 mL of 0.1 mol L -1 HNO 3 containing 10 ng mL -1 indium as an internal standard. The eluent was analyzed for the metal concentrations using ICP-MS. Sample pH as well as the sample and eluent flow rates were optimized. The sorption capacity of resin was determined by the batch process, by equilibrating 0.05 g of the resin with solutions of 50 mL of 25 mg L -1 of individual metal ions for 4 h at pH 6.0 at 26 deg. C. The sorption capacities for the resin were found to range between 47.3 μmol g -1 (for Lu) and 136.7 μmol g -1 (for Gd). Limits of detection (3σ), without any preconcentration, ranged from 2 ng L -1 to 10.3 ng L -1 (for Tm and Lu respectively). The proposed method was applied to the determination of REEs in seawater and tap water samples.

  16. Speciation of mercury by ion chromatography with post-column derivatization

    International Nuclear Information System (INIS)

    Foltin, M.; Megova, S.; Prochakova, T.; Steklac, M.

    1996-01-01

    The chromatographic behaviour of Hg(II), methylmercury, phenylmercury and Cu(II) on three different sorbents, strong acidic sulfobutyl cation-exchanger, weak basic aminopropyl anion-exchanger and silicagel has been studied. A dithizone solution in cetyltrimethylammonium hydrogensulfate water micellar medium was found as a useful post-column derivatization reagent for UV-VIS detection. The detection limits 1.1 ng, 2.2 ng, 6.2 ng and 1.6 ng were found in silicagel chromatographic system and dithizone detection system for Hg(II), methylmercury, phenylmercury and respectively for Cu(II). (author). 18 refs., 4 figs., 3 tabs

  17. Quality control of radiopharmaceuticals with HPLC using aqueous size exclusion spherogel column

    International Nuclear Information System (INIS)

    Vallabhajosula, S.; Goldsmith, S.J.; Lipszyc, H.

    1982-01-01

    The application of HPLC for the analysis and quality control of 99 Tc-radiopharmaceuticals, using a weakly basic anion exchange column, has been reported. This HPLC method for the separation of the components is based on molecular size. 99 Tc-MDP, 99 Tc-HDP and 99 Tc-DTPA were analysed and UV absorption studies carried out on the components. Components of the 99 Tc-MDP separation were injected into rabbits and renal excretion and serial images studied. (U.K.)

  18. Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater

    Science.gov (United States)

    Jiménez, María. S.; Velarte, Rosario; Castillo, Juan R.

    2002-03-01

    A simple, versatile and economical method of sequential injection analysis and inductively coupled plasma-mass spectrometry with matrix removal in two different ion-exchange resins for the determination of Al, As, Co, Cu, Mn, Mo, Ni, Pb and V is reported. The resins used, both of which contain the iminodiacetic acid functional group, were Chelex 100 and Metpac CC-1. With both resins, a matrix removal step (alkaline and alkaline-earth metals) with ammonium acetate is required before elution of the analytes with 2 M HNO 3. The procedure was validated by analyzing CASS-3 seawater reference material and good agreement was found with the certified values. Precision ( n=8) for the nine elements was in the range 0.8-4.9% for the Chelex 100 column and the recoveries ranged from 87.4 to 107.9%, except for Cu (78.7%) and Pb (74.9%), owing to the formation of hydroxides. For the Metpac CC-1 column, precision for the nine elements was in the range 1.2-7.1% and the recoveries between 91.7 and 109.3%, except for Al (127.2%), Co (118.5%) and Ni (127.5%) due to contamination problems.

  19. Separation and determination of 4-methylimidazole, 2-methylimidazole and 5-hydroxymethylfurfural in beverages by amino trap column coupled with pulsed amperometric detection.

    Science.gov (United States)

    Xu, Xian-Bing; Liu, Ding-Bo; Yu, Shu-Juan; Yu, Pei; Zhao, Zhen-Gang

    2015-02-15

    A method for simultaneous determination of 4-methylimidazole (4-MeI), 2-methylimidazole (2-MeI) and 5-hydroxymethylfurfural (HMF) in beverages was developed using solid-phase extraction (SPE) and amino trap column coupled with pulsed amperometric detection (AMTC-PAD). A single amino trap column (P/N: 046122) was first applied to separate the targeted analytes in samples after SPE pretreatment. This method demonstrated low limit of quantification (0.030mg/L for methylimidazoles and 0.300mg/L for HMF) and excellent linearity with correlation of determination (R(2)=0.999 for 2-MeI, 0.997 for 4-MeI and 0.998 for HMF). Nearly no 2-MeI was found in all soft drinks. However, 4-MeI could be detected in cola drinks and soft drinks containing caramel colour (ranging from 0.13 to 0.34mg/L), whereas HMF were only found in cola drinks (ranging from 1.07 to 4.47mg/L). Thus, AMTC-PAD technique would be a valid and inexpensive alternative to analysis of 4-MeI, 2-MeI and HMF. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Coupling of a Trivelpiece-Gould wave to a new type of electromagnetic wave observed around the electron cyclotron frequency in an inhomogeneous plasma column

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, J.A.C. (Instituto Superior Tecnico, Lisbon (Portugal). Centro de Electrodinamica)

    1989-02-01

    The coupling between a Trivelpiece-Gould wave with a frequency close to the electron cyclotron frequency to a fast wave, propagating with almost the light velocity in vacuum inside a metallic cylindrical waveguide much below cutoff, is observed along a magnetized plasma column with a strong axial density gradient. The fast wave is characterized by the experimental determination of its dispersion as well as by measurements of its electric and magnetic field radial structures and associated polarization. A preliminary theoretical description of this electromagnetic wave, consistent with all the relevant experimental observations, is presented, strongly suggesting that it belongs to a kind of radially evanescent modified cold plasma ''left-ordinary'' mode. (author).

  1. Coupling sequential injection on-line preconcentration using a PTFE beads packed column to direct injection nebulization inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes and chela......An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes...... and chelating reagent, diethyldithiophosphate (DDPA), are formed and adsorbed onto the surface of the PTFE beads. The adsorbed complexes are afterwards eluted with 20% nitric acid and the leading part of the eluate (40 mul) is stored in a sample loop (SL), the contents of which are subsequently transported, via...

  2. Numerical investigation with a coupled single-column lake-atmosphere model: An application to Western Switzerland

    Science.gov (United States)

    Goyette, Stéphane

    2017-04-01

    The potential of a novel atmospheric single-column model (SCM) developed in the framework of the Canadian Regional Climate Model, CRCM, driven by NCEP-NCAR reanalyses is investigated. The approach to solve the model equations and the technique described here may be implemented in any RCM system environment as a model option. The working hypothesis underlying this SCM formulation is that a substantial portion of the variability simulated in the column can be reproduced by processes operating in the vertical dimension and a lesser portion comes from processes operating in the horizontal dimension. This SCM offers interesting prospects as the horizontal and vertical resolution of the RCM is ever increasing. Due to its low computational cost, multiple simulations may be carried out in a short period of time. In this paper, a range of possible results from changing the lower boundary from land to open water surface, and varying model parameters are shown for western Switzerland. The benefit of using Newtonian relaxation, or "nudging", is demonstrated. Results show that air temperature, moisture and windspeed profiles are modified in a coherent manner in the lowest levels. Such changes are consistent with those of the surface vertical sensible, latent heat and momentum fluxes. Compared to atmospheric profiles over land, switching to and open water surface representative of Lake Geneva over the annual cycle of 1990, air temperature is increased by up to 1°C during the autumn and winter seasons, and by 0.5°C during the spring and summer seasons. Specific humidity is increased by up to 0.2 g kg-1 during the autumn and winter seasons and decreased by 0.3 g kg-1 during the spring and summer seasons. The increased windspeed at the surface, often more than 1.5 m s-1, is due to the smaller roughness height. The surface radiation and energy budgets are also modified subsequent to the different partionning of the latent end sensible heat fluxes, but also the solar and thermal

  3. Selective isolation of β-glucan from corn pericarp hemicelluloses by affinity chromatography on cellulose column.

    Science.gov (United States)

    Yoshida, Tomoki; Honda, Yoichi; Tsujimoto, Takashi; Uyama, Hiroshi; Azuma, Jun-ichi

    2014-10-13

    A combination of anion-exchange chromatography and affinity chromatography on a cellulose column was found to be effective for the isolation of β-(1,3;1,4)-glucan (BG) from corn pericarp hemicelluloses (CPHs). CPHs containing 6.6% BG were extracted from corn pericarp with 6M urea-2 wt% NaOH solution and initially fractionated into neutral and acidic parts by anion exchange chromatography to remove acidic arabinoxylan consisting of arabinose (35.6%) and xylose (50.9%). The neutral fraction (yield; 10.1% on the basis of CPHs) consisting of 1.0% arabinose, 10.1% xylose and 80.3% glucose containing 28.4% BG was then applied to a cellulose column of Whatman CF-11. BG could be recovered from the adsorbed fraction on the cellulose column by elution with 2% NaOH in a yield of 2.6% on the basis of CPHs with a purity of 84.7%. The chemical structure of the isolated corn pericarp BG was confirmed by (13)C NMR spectroscopic, methylation and lichenase treatment analyses. The results indicate that the ratios of (1,4)/(1,3) linkage and cellotriosyl/cellotetraosyl segments of the BG were 2.60 and 2.5, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Study of the leaching of heavy metals from waste water sludge and incinerator's ash, using coupled thermostated columns and DTPA as complex agent

    International Nuclear Information System (INIS)

    Vite T, J.; Vite T, M.; Guerrero D, J.; Carreno de Leon, M.C.

    2000-01-01

    We studied the metallic composition from waste water sludge and incinerators ashes of an incinerator located in Toluca, Mexico, the qualitative studies were made using the Activation Analysis technique, and fluorescence X-ray techniques. The quantitative analysis of heavy metals in the wastes were made using Inductively coupled plasma atomic emission spectrometry (Icp-Aes). For leaching the samples, we used four coupled thermostated columns, each one had a p H of 2,5, 7 and 10. The flux of the air was of 1600 cc/min. The temperature was maintain constant in 60 Centigrade using a thermostated system. For this study we used 100 g of wastes mixed with mineral acid or sodium hydroxide to reach p H 2,5,7 and 10. We added a reducing and tensoactive agents and finally DTPA as complex agent. With this method, we obtain a better leaching efficiency using a complex agent. However the high DTPA cost, make this process expansive that is why we recommend to work with another classes of complex agents, that be cheaper to leach metals of different chemistry matrix. (Author)

  5. Assessment of the aerosol optics component of the coupled WRF-CMAQ model using CARES field campaign data and a single column model

    Science.gov (United States)

    Gan, Chuen Meei; Binkowski, Francis; Pleim, Jonathan; Xing, Jia; Wong, David; Mathur, Rohit; Gilliam, Robert

    2015-08-01

    The Carbonaceous Aerosols and Radiative Effects Study (CARES), a field campaign held in central California in June 2010, provides a unique opportunity to assess the aerosol optics modeling component of the two-way coupled Weather Research and Forecasting (WRF) - Community Multiscale Air Quality (CMAQ) model. This campaign included comprehensive measurements of aerosol composition and optical properties at two ground sites and aloft from instrumentation on-board two aircraft. A single column model (SCM) was developed to evaluate the accuracy and consistency of the coupled model using both observation and model information. Two cases (June 14 and 24, 2010) are examined in this study. The results show that though the coupled WRF-CMAQ estimates of aerosol extinction were underestimated relative to these measurements, when measured concentrations and characteristics of ambient aerosols were used as input to constrain the SCM calculations, the estimated extinction profiles agreed well with aircraft observations. One of the possible causes of the WRF-CMAQ extinction errors is that the simulated sea-salt (SS) in the accumulation mode in WRF-CMAQ is very low in both cases while the observations indicate a considerable amount of SS. Also, a significant amount of organic carbon (OC) is present in the measurement. However, in the current WRF-CMAQ model all OC is considered to be insoluble whereas most secondary organic aerosol is water soluble. In addition, the model does not consider external mixing and hygroscopic effects of water soluble OC which can impact the extinction calculations. In conclusion, the constrained SCM results indicate that the scattering portion of the aerosol optics calculations is working well, although the absorption calculation could not be effectively evaluated. However, a few factors such as greatly underestimated accumulation mode SS, misrepresentation of water soluble OC, and incomplete mixing state representation in the full coupled model

  6. Affinity selection-based two-dimensional chromatography coupled with high-performance liquid chromatography-mass spectrometry for discovering xanthine oxidase inhibitors from Radix Salviae Miltiorrhizae.

    Science.gov (United States)

    Fu, Yu; Mo, Hua-Yan; Gao, Wen; Hong, Jia-Ying; Lu, Jun; Li, Ping; Chen, Jun

    2014-08-01

    Xanthine oxidase (XOD) is a key oxidative enzyme to the pathogenesis of hyperuricemia and certain diseases induced by excessive reactive oxygen species. XOD inhibitors could provide an important therapeutic approach to treat such diseases. A new method using affinity selection-based two-dimensional chromatography coupled with liquid chromatography-mass spectrometry was developed for the online screening of potential XOD inhibitors from Radix Salviae Miltiorrhizae. Based on our previous study, the two-dimensional, turbulent-flow chromatography (TFC) was changed to a mixed-mode anion-exchange/reversed-phase column and one reversed-phase column. The developed method was validated to be selective and sensitive for screening XOD-binding compounds, especially weak acidic ones, in the extracts. Three salvianolic acids were screened from the Radix Salviae Miltiorrhizae extract via the developed method. The XOD inhibitory activities of salvianolic acid C and salvianolic acid A were confirmed, and their inhibitory modes were measured. Salvianolic acid C exhibited potent XOD inhibitory activity with an IC(50) of 9.07 μM. This work demonstrated that the developed online, two-dimensional TFC/LC-MS method was effective in discovering the binding affinity of new compounds from natural extracts for target proteins, even at low concentrations.

  7. Determination of myo-inositol hexakisphosphate (phytate) in urine by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Grases, F.; Perello, J.; Isern, B.; Prieto, R.M

    2004-05-10

    Myo-inositol hexakisphosphate (phytate) is a substance present in urine with an important role in preventing calcium renal calculi development. In spite of this, the use of urinary phytate levels on stone-formers' evaluation and treatment is still notably restricted as a consequence of the enormous difficulty to analyze this substance in urine. In this paper, a simple procedure for routinary urinary phytate determination based on phosphorus determination through inductively coupled plasma atomic emission spectrometry is described. The method only requires a previous separation of phytate from other components by column anion exchange chromatography. The working linear range used was 0-2 mg l{sup -1} phosphorus (0-7 mg l{sup -1} phytate). The limit of detection was 64 {mu}g l{sup -1} of phytate and the limit of quantification was 213 {mu}g l{sup -1}. The relative standard deviation (R.S.D.) for 1.35 mg l{sup -1} phytate was 2.4%. Different urine samples were analyzed using an alternative analytical methodology based on gas chromatography (GC)/mass detection used for inositol determination (phytate was previously hydrolyzed), resulting both methods comparable using as criterion to assess statistical significance P<0.05.

  8. Numerical investigation with a coupled single-column lake-atmosphere model: using the Alpert-Stein factor separation methodology to assess the sensitivity of surface interactions

    Science.gov (United States)

    Goyette, Stéphane

    2017-04-01

    A coupled single-column atmosphere-lake model, along with the Stein-Alpert factor separation methodology, is used to explore some of the non-linear interactions in the vertical dimension between the lower atmosphere and the deep-Lake Geneva, Switzerland, during three selected periods in 1990. The first from the end of April to the end of May when Lake Geneva was building its stratification, the second from mid-August to mid-September during stable stratification, and the third from the end of November to the end of December during destratification. It is recognized that the large thermal inertia of Lake Geneva reduces the surface annual and diurnal temperature variations for neighbouring regions. However, the question of how the open water and the overlying atmosphere interact and which of these "factors" has the most influence needs much attention. The sole presence of the lake is shown to be a major feature with regard to the surface energy budget components whose contributions counteract those of the lower atmosphere, thus supporting the fact that Lake Geneva acts as a damping factor to the regional climate system. It is also shown that not only did the presence of the lake and the overlying atmosphere independently modulate the surface energy budget, but also the synergistic nonlinear interaction among them, either positive or negative, was often found non-negligible. Moreover, some processes may turn out to be important on short time scales while being negligible on the long term.

  9. In-situ ionic liquid dispersive liquid-liquid microextraction using a new anion-exchange reagent combined Fe3O4magnetic nanoparticles for determination of pyrethroid pesticides in water samples.

    Science.gov (United States)

    Fan, Chen; Liang, You; Dong, Hongqiang; Ding, Guanglong; Zhang, Wenbing; Tang, Gang; Yang, Jiale; Kong, Dandan; Wang, Deng; Cao, Yongsong

    2017-07-04

    In this work, in-situ ionic liquid dispersive liquid-liquid microextraction combined ultrasmall Fe 3 O 4 magnetic nanoparticles was developed as a kind of pretreatment method to detect pyrethroid pesticides in water samples. New anion-exchange reagents including Na[DDTC] and Na[N(CN) 2 ] were optimized for in-situ extraction pyrethroids, which showed enhanced microextraction performance. Pyrethroids were enriched by hydrophilic ionic liquid [P 4448 ][Br] (aqueous solution, 200 μL, 0.2 mmol mL -1 ) reaction in-situ with anion-exchange reagent Na[N(CN) 2 ] (aqueous solution, 300 μL, 0.2 mmol mL -1 ) forming hydrophobic ionic liquid as extraction agent in water sample (10 mL). Ultrasmall superparamagnetic iron oxide nanoparticles (30 mg) were used to collect the mixture of ionic liquid and pyrethroids followed by elution with acetonitrile. The extraction of ionic liquid strategies was unique and efficiently fulfilled with high enrichment factors (176-213) and good recoveries (80.20-117.31%). The method was successively applied to the determination of pyrethroid pesticides in different kinds of water samples with the limits of detection ranged from 0.16 to 0.21 μg L -1 . The proposed method is actually nanometer-level microextraction (average size 80 nm) with the advantages of simplicity, rapidity, and sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Distribution of 14 elements from two solutions simulating Hanford HLW Tank 102-SY (acid-dissolved sludge and acidified supernate) on four cation exchange resins and five anion exchange resins having different functional groups

    International Nuclear Information System (INIS)

    Marsh, S.F.; Svitra, Z.V.; Bowen, S.M.

    1995-01-01

    As part of the Tank Waste Remediation System program at Los Alamos, we evaluated a series of cation exchange and anion exchange resins for their ability to remove hazardous components from radioactive high-level waste (HLW). The anion exchangers were Reillex TM HPQ, a polyvinyl pyridine resin, and four strong-base polystyrene resins having trimethyl, tri ethyl, tri propyl, and tributyl amine as their respective functional groups. The cation exchange resins included Amberlyst TM 15 and Amberlyst tM XN-1010 with sulfonic acid functionality, Duolite TM C-467 with phosphonic acid functionality, and poly functional Diphonix TM with di phosphonic acid, sulfonic acid, and carboxylic acid functionalities. We measured the distributions of 14 elements on these resins from solutions simulating acid-dissolved sludge (pH 0.6) and acidified supernate (pH 3.5) from underground storage tank 102-SY at the Hanford Reservation near Richland, Washington, USA. To these simulants, we added the appropriate radionuclides and used gamma spectrometry to measure fission products (Ce, Cs, Sr, Tc, and Y), actinides (U, Pu, and Am), and matrix elements (Cr, Co, Fe, Mn, Zn, and Zr). For each of the 252 element/resin/solution combinations, distribution coefficients (Kds) were measured for dynamic contact periods of 30 minutes, 2 hours, and 6 hours to obtain information about sorption kinetics from these complex media. Because we measured the sorption of many different elements, the tabulated results indicate which unwanted elements are most likely to interfere with the sorption of elements of special interest. On the basis of these 756 measured Kd values, we conclude that some of the tested resins appear suitable for partitioning hazardous components from Hanford HLW. (author). 10 refs., 11 tabs

  11. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Freese, R.; Cornett, C.

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...... by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, it = 12). A subset of 10 urine samples from a human dietary intervention study...

  12. Fast Determination of Toxic Arsenic Species in Food Samples Using Narrow-bore High-Performance Liquid-Chromatography Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Terol, Amanda; Marcinkowska, Monika; Ardini, Francisco; Grotti, Marco

    2016-01-01

    A new method for the speciation analysis of arsenic in food using narrow-bore high-performance liquid-chromatography inductively coupled plasma mass spectrometry (HPLC-ICP-MS) has been developed. Fast separation of arsenite, arsenate, monomethylarsonic acid and dimethylarsinic acid was carried out in 7 min using an anion-exchange narrow-bore Nucleosil 100 SB column and 12 mM ammonium dihydrogen phosphate of pH 5.2 as the mobile phase, at a flow rate of 0.3 mL min(-1). A PFA-ST micronebulizer jointed to a cyclonic spray chamber was used for HPLC-ICP-MS coupling. Compared with standard-bore HPLC-ICP-MS, the new method has provided higher sensitivity, reduced mobile-phase consumption, a lower matrix plasma load and a shorter analysis time. The achieved instrumental limits of detection were in the 0.3 - 0.4 ng As mL(-1) range, and the precision was better than 3%. The arsenic compounds were efficiently (>80%) extracted from various food samples using a 1:5 methanol/water solution, with additional ultrasonic treatment for rice products. The applicability of this method was demonstrated by the analysis of several samples, such as seafood (fish, mussels, shrimps, edible algae) and rice-based products (Jasmine and Arborio rice, spaghetti, flour, crackers), including three certified reference materials.

  13. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  14. NEW METHOD FOR REMOVAL OF SPECTRAL INTERFERENCES FOR BERYLLIUM ASSAY USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S; Matthew Nelson, M; Linda Youmans, L; Maureen Bernard, M

    2008-01-14

    Beryllium has been used widely in specific areas of nuclear technology. Frequent monitoring of air and possible contaminated surfaces in U.S Department of Energy (DOE) facilities is required to identify potential health risks and to protect DOE workers from beryllium-contaminated dust. A new method has been developed to rapidly remove spectral interferences prior to beryllium (Be) measurement by inductively-coupled plasma atomic emission spectrometry (ICP-AES). The ion exchange separation removes uranium (U), thorium (Th), niobium (Nb), vanadium (V), molybdenum (Mo), zirconium (Zr), tungsten (W), iron (Fe), chromium (Cr), cerium (Ce), erbium (Er) and titanium (Ti). A stacked column consisting of Diphonix Resin{reg_sign} and TEVA Resin{reg_sign} reduces the levels of the spectral interferences so that low level Be measurements can be performed accurately. If necessary, an additional anion exchange separation can be used for further removal of interferences, particularly chromium. The method has been tested using spiked filters, spiked wipe samples and certified reference material standards with high levels of interferences added. The method provides very efficient removal of spectral interferences with very good accuracy and precision for beryllium on filters or wipes. A vacuum box system is employed to reduce analytical time and reduce labor costs.

  15. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  16. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  17. Anion-exchange and anthracene-encapsulation within copper(II) and manganese(II)-triazole metal-organic confined space in a single crystal-to-single crystal transformation fashion.

    Science.gov (United States)

    Liu, Ju-Yan; Wang, Qian; Zhang, Li-Jun; Yuan, Bin; Xu, Yao-Yao; Zhang, Xin; Zhao, Cong-Ying; Wang, Dan; Yuan, Yue; Wang, Ying; Ding, Bin; Zhao, Xiao-Jun; Yue, Min Min

    2014-06-16

    A new multidentate ligand 1-(9-(1H-1,2,4-triazol-1-yl)anthracen-10-yl)-1H-1,2,4-triazole (tatrz) was designed and synthesized. Using tatrz as a building block, three novel coordination frameworks, namely, {[Cu(tatrz)2(NO3)2]·(CH3OH)·4H2O}n (1), {[Cu(tatrz)2(H2O)2](BF4)2}n (2), and [Mn(tatrz)2(SCN)2(CH3OH)]·2H2O (3) can be isolated. Anion-exchange experiment indicates that NO3(-) anions in the two-dimensional (2D) copper framework of 1 can be completely exchanged by ClO4(-) in an irreversible single crystal-to-single crystal (SC-SC) transformation fashion, as evidenced by the anion-exchange products of {[Cu(tatrz)2(H2O)2](ClO4)2·4CH3OH} (1a). Further, if 1a was employed as a precursor in N,N-dimethylformamide (DMF), an isomorphic solvate of {[Cu(tatrz)2(DMF)2](ClO4)2·2H2O}n (1b) can be generated during the reversible dynamic transformation process. When 1 was immersed in CH3OH, a distinct 2D layer {[Cu(tatrz)2(NO3)2]·4.4CH3OH·0.6H2O}n (1c) was isolated. Interestingly, the solvent-exchange conversion is also invertible between 1 and 1c, which exhibits spongelike dynamic behavior with retention of crystalline integrity. If the 2-fold interpenetrating three-dimensional (3D) framework 2 is selected, it can be transformed into another 2-fold interpenetrating 3D framework {[Cu(tatrz)2(H2O)2](ClO4)2·5.56H2O}n (2a) in a reversible SC-SC transformation fashion. However, when the light yellow crystals of mononuclear complex 3 were exposed to trichloromethane containing aromatic organic anthracene (atan), through our careful observation, the crystals of 3 were dissolved and reassembled into dark brown crystals of 2D crystalline coordination framework {[Mn(tatrz)2(SCN)2]·(atan)}n (3a). X-ray diffraction revealed that in 3a, atan acting as an organic template was encapsulated in the confined space of the 2D grid. Luminescent measurements illustrate that 3a is the first report of multidimensional polymers based on triazole derivatives as luminescent probes of Mg(2+).

  18. APLIKASI PENGOLAHAN POLUTAN ANION KHROM(VI DENGAN MENGGUNAKAN AGEN PENUKAR ION HYDROTALCIT ZN-AI-SO4 (Synthesis of and its Application to Treat Chrom(VI Pollutant Using Hydrotalcite Zn-Al_SO4 as Anion Exchanger

    Directory of Open Access Journals (Sweden)

    Roto Roto

    2009-03-01

    Full Text Available ABSTRAK Keberadaan logam khrom di dalam sistem perairan bersifat polutan yang harus ditangani dengan baik, dan untuk khrom (Vl yang sering dijumpai dalam bentuk anion dapat diolah dengan menggunakan mekanisme pertukaran ion. Suatu agen penukar anion telah dibuat berupa senyawa hidrotalsit Zn-Al-SOa melalui proses sintesis, karakterisasi serta dilakukan pula pengujian aplikasinya untuk pengurangan polutant anion khrom (VI dalam bentuk ion dikromat. Sintesis hidrotalsit Zn-Al-SOa dilakukan dengan metode stoikiometri pada pH 8 dan perlakuan hidrotermal. Aplikasi pertukaran dikromat dengan anion sulfat dalam antar lapis hidrotalsit serta uji regenerasi bahan diamati dengan bantuan analisis struktur dan analisis kinetika reaksi pertukaran. Produk pertukaran ion dikarakterisasi dengan XRD, spektrofotometri IR dan spektrometri serapan atom. Rumus kimia hidrotalsit produk diketahui adalah Zn0,74Al0,26(OH1,74(SO40,13.0,52H2O. Anion dikromat dapat menukar sulfat dalam antarlapis hidrotalsit yang ditunjukkan dalam spektra IR dan pola XRD. Kapasitas pertukaran anion untuk dikromat diketahui 216,84 mek/100 g, sedangkan kinetika reaksi pertukaran ion mengikuti orde dua dengan k = 3 x 10-8 ppm-1.detik-1. Hasil menunjukkan Zn-Al-Cr2O7 dapat mudah diregenerasi.    ABSTRACT  Chrom as pollutant in aquatics system usually establishes as crom (VI and should be worked with special treatment and as an example is ion exchanger. Material Zn-Al-SO4 hydrotalcite product have been synthesized and its application as anion exchanger for dichromate have been studied. Synthesis of Zn-Al-SO4 hydrotalcite was carried out by stoichiometric method at pH 8 and hydrothermal treatment. Sulphate in hydrotalcite interlayer was exchanged by dichromate. Kinetics of ion exchange was also investigated. The product of ion exchange was characterized by XRD, IR spectrophotometry and atomic adsorption  spectrometry. The chemical formula of the  hydrotalcite is Zn0.74Al0.26(OH1.74(SO4 0

  19. Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

    Energy Technology Data Exchange (ETDEWEB)

    Luong, Elise [Iowa State Univ., Ames, IA (United States)

    1999-05-10

    This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 ± 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-trace concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 ± 0.4 ng/g, while the certified value is 11.5 ± 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 ± 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry (GC-combustion-IRMS). Trytophan, myoglobin, and β-cyclodextrin are chosen for the study, initial observation of spectral interference of 13C+ with 12C 1H+ comes from the incomplete dissociation of myoglobin and/or β-cyclodextrin.

  20. Development of rapid plutonium analysis for environmental samples by isotope dilution/inductively coupled plasma mass spectrometry with on-line column.

    Science.gov (United States)

    Ohtsuka, Yoshihito; Takaku, Yuichi; Kimura, Jyoji; Hisamatsu, Shun'ichi; Inaba, Jiro

    2005-03-01

    This paper describes our development of a rapid on-line column/ID-ICP-MS technique for the analysis of plutonium (Pu) in environmental samples using an UTEVA extraction chromatograph resin (UTEVA resin) column. It took only 40 min to separate and measure Pu in the sample solution, including the time for conditioning the resin column for the next analysis. In our method, Pu in a 3 M nitric acid solution was fed to the UTEVA resin, and then eluted from the resin by reducing Pu to Pu(III) with 3 M nitric acid mixed with 0.01 M ascorbic acid after washing the resin. The outflow from the resin column was directly introduced to an ICP-MS system. The low concentration of ascorbic acid and the small volume of the eluting solution (0.6 mL) made successive stable analysis possible without any skimmer cone clogging. The chemical recovery of Pu during column operation was 70%, and typical lower detection limits for 239Pu, 240Pu and 242Pu were 9.2, 4.3 and 7.5 fg (21, 36 and 1.1 microBq), respectively. We analyzed five international standard materials for Pu, and obtained good results.

  1. Np(V) transport in clayey porous medium: study of solution chemistry, sorption and flow coupling

    International Nuclear Information System (INIS)

    Andre, Christine

    1997-01-01

    To assess the safety of radioactive waste disposal, the behaviour of radionuclides in porous media has to be known. The solute transport is controlled by hydrodynamics, physicochemical interactions and aqueous chemistry. When each main term is known independently, their coupling can be predicted. The aim is to study the migration of Np(V). Experiments are carried out on chromatography columns packed with a mixture of sand and Fo-Ca-7 clay. Column hydrodynamics is characterised with RTD measurements and is modelled thanks to a cell network model. Sorption properties of the clay are determined thanks to sodium/calcium and sodium/caesium exchange experiments. The sorption is modelled with ion exchange on three sites. The Na + /H + , Na + /Ca 2+ and Na + /Cs + exchange constants have been determined. Transport experiments of Np(V) have been carried out in IM Na + bicarbonate/carbonate media and is interpreted with H + /NpO 2+ /Na + cationic exchanges on the third site of the clay, and NpO 2 CO 3- , NpO 2 (CO 3 ) 2 3- and NpO 2 (CO 3 ) 3 5- formation. This mechanism has been validated by varying pH and carbonate concentration. An anion exchange site of low exchange capacity has been found through 14 C experiments. A selective elimination of goethite contained in Fo-Ca-7 shows that this iron oxide is not responsible for the anions retention. As expected, temperature influence on calcium and neptunium migration is quite small. It is used to estimate entropy and enthalpy changes for the corresponding ionic exchange reactions. (author) [fr

  2. [Determination of five avermectins in bovine liver by on-line solid-phase extraction with hydrophobic monolithic column coupled with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Xin; Zhang, Yaoqin; Ai, Lianfeng; Wang, Xuesheng; Wang, Manman; Xu, Houjun; Hao, Yulan

    2015-06-01

    A method based on on-line solid-phase extraction (SPE) with hydrophobic monolithic column coupled with high performance liquid chromatography-tandem mass spectrometry was developed for the simultaneous determination of five avermectins in bovine liver. A poly(butyl methacrylate-co-ethylene dimethacrylate) monolithic column was used as the sorbent. The parameters influenced on on-line SPE and separation process such as the loading mobile phase, the eluting flow rate and the solvent for the separation were investigated in detail. Blank samples, spiked samples, matrix effect and recovery experiments were investigated to evaluate the extraction efficiency and potential interfering compounds originating from the matrix. Under the optimized conditions, the method showed a linear range of 1-100 µg/L and the quantification limit of 5 µg/kg for each analyte. The presented method gave recoveries of 77.4%-98.4%. The relative standard deviations of intra-day and inter-day were 4.46%-8.03% and 4.79%-8.68%, respectively. Moreover, no significant changes were found in the extraction performance after more than 400 usages on one monolithic column, and even on the monoliths with various batches. The feasibility of the developed poly (butyl methacrylate-coethylene dimethacrylate) monolithic column based on the on-line SPE method for the determination of avermectins was further demonstrated by the analysis of real samples.

  3. Separation and quantification of inulin in selected artichoke (Cynara scolymus L.) cultivars and dandelion (Taraxacum officinale WEB. ex WIGG.) roots by high-performance anion exchange chromatography with pulsed amperometric detection.

    Science.gov (United States)

    Schütz, Katrin; Muks, Erna; Carle, Reinhold; Schieber, Andreas

    2006-12-01

    The profile of fructooligosaccharides and fructopolysaccharides in artichoke heads and dandelion roots was investigated. For this purpose, a suitable method for high-performance anion exchange chromatography with pulsed amperometic detection was developed. The separation of monomers, oligomers and polymers up to a chain length of 79 sugar residues was achieved in one single run. Glucose, fructose, sucrose and individual fructooligosaccharides (kestose, nystose, fructofuranosylnystose) were quantified in six different artichoke cultivars and in dandelion roots. The contents ranged from 12.9 g/kg DM to 71.7 g/kg DM for glucose, from 15.8 g/kg DM to 67.2 g/kg DM for fructose, and from 16.8 g/kg DM to 55.2 g/kg DM for sucrose in the artichoke heads. Kestose was the predominant fructooligosaccharide, followed by nystose and fructofuranosylnystose. In four cultivars fructofuranosylnystose was only detectable in traces and reached its maximum value of 3.6 g/kg DM in the cultivar Le Castel. Furthermore, an average degree of polymerization of 5.3 to 16.7 was calculated for the individual artichoke cultivars, which is noticeably lower than hitherto reported. In contrast, the contents of kestose, nystose and fructofuranosylnystose in dandelion root exceeded that of artichoke, reflecting the short chain characteristic of the inulin, which was confirmed by chromatographic analysis. Copyright (c) 2006 John Wiley & Sons, Ltd.

  4. Method for immobilizing invertase by adsorption on Dowex® anionic exchange resin Método para a imobilização da invertase por adsorção em resinas trocadoras de ânions (DOWEX

    Directory of Open Access Journals (Sweden)

    Ester Junko Tomotani

    2006-06-01

    Full Text Available This communication describes a method for adsorbing the invertase (EC.3.2.1.26 on DOWEX® anion exchange resin. Among the types of DOWEX® resins studied (1x8:50-400; 1x4:50-400 and 1x2:100-400, 1X4-200 was the most suitable, because it adsorbed the invertase molecules completely and the complex 1X4-200/invertase retained 100% of the catalytic activity. Moreover, no leakage of enzyme from the support was noted at the end of the sucrose hydrolysis.O presente trabalho descreve um método de adsorção da invertase (EC. 3.2.1.26 na resina de troca aniônica do tipo Dowex®. Entre os tipos de resinas Dowex® estudados (1x8:50-400; 1x4:50-400 e 1x2:100-400, 1x4-200 foi a mais apropriada devido à completa adsorção das moléculas de invertase e a sua retenção de atividade catalítica de 100% do complexo 1x4-200/invertase. Salienta-se ainda a ausência do desprendimento da enzima do suporte após o término da hidrólise da sacarose.

  5. Investigation of patterned and non-patterned poly(2,6-dimethyl 1,4-phenylene) oxide based anion exchange membranes for enhanced desalination and power generation in a microbial desalination cell.

    Science.gov (United States)

    Moruno, Francisco Lopez; Rubio, Juan E; Santoro, Carlo; Atanassov, Plamen; Cerrato, José M; Arges, Christopher G

    2018-01-01

    Quaternary ammonium poly(2,6-dimethyl 1,4-phenylene oxide) (QAPPO) anion exchange membranes (AEMs) with topographically patterned surfaces were assessed in a microbial desalination cell (MDC) system. The MDC results with these QAPPO AEMs were benchmarked against a commercially available AEM. The MDC with the non-patterned QAPPO AEM (Q1) displayed the best desalination rate (a reduction of salinity by 53 ± 2.7%) and power generation (189 ± 5 mW m - 2 ) when compared against the commercially available AEM and the patterned AEMs. The enhanced performance with the Q1 AEM was attributed to its higher ionic conductivity and smaller thickness leading to a reduced area specific resistance. It is important to note that Real Pacific Ocean seawater and activated sludge were used into the desalination chamber and anode chamber respectively for the MDC - which mimicked realistic conditions. Although the non-patterned QAPPO AEM displayed better performance over the patterned QAPPO AEMs, it was observed that the anodic overpotential was smaller when the MDCs featured QAPPO AEMs with larger lateral feature sizes. The results from this study have important implications for the continuous improvements necessary for developing cheaper and better performing membranes in order to optimize the MDC.

  6. Serial mixed-mode cation- and anion-exchange solid-phase extraction for separation of basic, neutral and acidic pharmaceuticals in wastewater and analysis by high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lavén, Martin; Alsberg, Tomas; Yu, Yong; Adolfsson-Erici, Margaretha; Sun, Hongwen

    2009-01-02

    A novel solid-phase extraction (SPE) method is presented whereby 15 basic, neutral and acidic pharmaceuticals in wastewater were simultaneously extracted and subsequently separated into different fractions. This was achieved using mixed-mode cation- and anion-exchange SPE (Oasis MCX and MAX) in series. Analysis was performed by high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (HPLC/QTOF-MS). A fast separation was achieved, with all compounds eluting within 6min, narrow chromatographic peaks, with a peak base width of 6s on average, and a high mass accuracy of quantified wastewater sample ions, with average mass errors in absolute value of 0.7mDa or 2.7ppm. The recovery of the SPE method in the analysis of sewage treatment plant (STP) influent and effluent wastewater was on average 80% and the ion suppression 30%. For less demanding samples Oasis MCX used alone may be an alternative method, although for STP influent waters containing high loads of organic compounds the clean-up achieved using only Oasis MCX was insufficient, leading to unreliable quantitation. Furthermore, serial SPE separation according to molecular charge added an additional degree of analyte confirmation. For quantitation, an approach combining external standard calibration curves, isotopically labelled surrogate standards and single-point standard addition was used. The applicability of the method was demonstrated in the analysis of influent and effluent wastewater from an STP, using small sample volumes (25-50mL). The effluent wastewater had been subjected to three different treatments; activated sludge, activated sludge followed by ozonation, and a membrane bioreactor (MBR). Ozone treatment proved superior in removal of the analysed pharmaceuticals, while the MBR provided higher removal efficiencies than the activated sludge process.

  7. Performance of polyethylene based radiation grafted anion exchange membrane with polystyrene-b-poly (ethylene/butylene)-b-polystyrene based ionomer using NiCo2O4 catalyst for water electrolysis

    Science.gov (United States)

    Gupta, Gaurav; Scott, Keith; Mamlouk, Mohamed

    2018-01-01

    A soluble anion exchange ionomer with high OH- ion conductivity comparable to that of H+ conductivity of Nafion is synthesised by chloromethylation of polystyrene-b-poly (ethylene/butylene)-b-polystyrene (SEBS) and used with NiCo2O4 electro-catalyst for water electrolysis. The ionomer has an ion exchange capacity of 1.9 mmol g-1 and ionic conductivity of 0.14 S cm-2 at 50 °C. The cell voltage at 20 °C at 100 mA cm-2 is 1.77 and 1.72 V in, 0.1 and 1.0 M NaOH, respectively, for an optimum loading of 10 mg cm-2 NiCo2O4. At 10 mg cm-2 NiCo2O4 electrolyser cell performance is at least equal to or superior to that of IrO2 at 2 mg cm-2 with excellent stability over 1 h. When the catalyst is sprayed on the GDL instead of CCM, the performance is further improved to 1.65 V at 100 mA cm-2 at 60 °C & 0.1 M KOH. The limited AEM electrolyser performance when operating with deionised water in comparison to PEM and alkaline electrolyser arises from the sluggish OER in the AEM environment equivalent to pH of 11.5 and the two orders of magnitude lower HER activity with respect to acid medium combined with the high Tafel slope of 120 mV dec-1.

  8. Enantiomer separation of a powerful chiral auxiliary, 2-methoxy-2-(1-naphthyl)propionic acid by liquid chromatography using chiral anion exchanger-type stationary phases in polar-organic mode; investigation of molecular recognition aspects.

    Science.gov (United States)

    Gyimesi-Forrás, Krisztina; Akasaka, Kazuaki; Lämmerhofer, Michael; Maier, Norbert M; Fujita, Takuma; Watanabe, Masataka; Harada, Nobuyuki; Lindner, Wolfgang

    2005-01-01

    The enantiodiscriminating potential of the weak anion exchange-type quinine-based chiral stationary phases (CSPs) for direct enantiomer separation of racemic 2-methoxy-2-(1-naphthyl)propionic acid (selectand, SA) was studied. The influence of structure variations of the selector (SO) in the carbamate functional group and/or in the C6' position of quinoline moiety on retention and enantioselectivity was investigated. Systematic chromatographic studies were made to gain more insight into the overall chiral recognition mechanism for a given mobile phase. In this context, the tert-butylcarbamoyl quinine and the corresponding diisopropylphenyl-derived selector provided the highest resolution and enantioselectivity under polar-organic conditions with the elution order of (R) before the (S) enantiomer. When the bulkiness of the substituents in the C6' position of the SO was increased, the selectivity was decreased in all cases. Alkylation of the nitrogen atom in the carbamate functionality of the SO resulted in the complete loss of enantiomer separation, confirming the crucial importance of the hydrogen-bond formation involved in the stereodiscriminating events. In addition, ten different mono-, bi-, or trivalent acids, necessary as competitor molecules (counter-ions) of the mobile phase, were screened to judge their influence on retention and overall enantioselectivity. Among them, acetic acid, formic acid, N-acetylglycine, and glycolic acid proved to be the most promising counter-ions with R(S) values of 6.35, 6.81, 8.19, and 7.34, respectively. On the basis of chromatographic data, a tentative molecular recognition model was proposed. Simultaneous ion-pairing and hydrogen bonding, in concert with pi-pi stacking and steric interactions, were expected to be responsible for chiral recognition mechanism. This was partially corroborated by structural and/or conformational analysis of the tert-butylcarbamoyl quinine-2-methoxy-2-(1-naphthyl)propionic acid (SO-SA) complex

  9. Multifunctional column coupled with liquid chromatography for determination of aflatoxins B1, B2, G1, and G2 in corn, almonds, brazil nuts, peanuts, and pistachio nuts: collaborative study.

    Science.gov (United States)

    Trucksess, M W; Stack, M E; Nesheim, S; Albert, R H; Romer, T R

    1994-01-01

    An AOAC/IUPAC collaborative study was conducted to evaluate the effectiveness of a multifunctional column for the determination of aflatoxins. The test portion is extracted with acetonitrile-water (9 + 1), the extract is filtered, and the filtrate is passed through the column. The aflatoxins in the eluate are determined by reversed-phase liquid chromatography after derivatization with trifluoroacetic acid. Naturally contaminated corn, almonds, Brazil nuts, peanuts, and pistachio nuts spiked with total aflatoxins at 5, 10, 20, and 30 ng/g were sent to 12 collaborators in the United States, Denmark, France, Japan, and Switzerland. Eleven collaborators completed the study. Average recoveries of total aflatoxins for each spike level for the various commodities (excluding Brazil nuts at 5 ng/g) were 93, 97, 95, and 95%, respectively; the repeatability relative standard deviation (RSDr) ranged from 6.0 to 23.2% and the reproducibility relative standard deviation (RSDR) ranged from 12.0 to 69.4%. The multifunctional column coupled with a liquid chromatographic method for determination of aflatoxins in corn, almonds, Brazil nuts, peanuts, and pistachio nuts has been adopted first action by AOAC INTERNATIONAL.

  10. Two-dimensional HPLC coupled to ICP-MS and electrospray ionisation (ESI)-MS/MS for investigating the bioavailability in vitro of arsenic species from edible seaweed

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Sartal, Cristina; Barciela-Alonso, Maria del Carmen; Bermejo-Barrera, Pilar [University of Santiago de Compostela, Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Santiago de Compostela (Spain); Taebunpakul, Sutthinun [LGC Limited, Teddington, Middlesex (United Kingdom); Imperial College of Science, Technology and Medicine, South Kensington, Department of Materials, London (United Kingdom); National Institute of Metrology (Thailand), Pathumthani (Thailand); Stokes, Emma; Goenaga-Infante, Heidi [LGC Limited, Teddington, Middlesex (United Kingdom)

    2012-04-15

    Edible seaweed consumption is a route of exposure to arsenic. However, little attention has been paid to estimate the bioaccessibility and/or bioavailability of arsenosugars in edible seaweed and their possible degradation products during gastrointestinal digestion. This work presents first use of combined inductively coupled plasma mass spectroscopy (ICP-MS) with electrospray ionization tandem mass spectrometry (ESI-MS/MS) with two-dimensional HPLC (size exclusion followed by anion exchange) to compare the qualitative and quantitative arsenosugars speciation of different edible seaweed with that of their bioavailable fraction as obtained using an in vitro gastrointestinal digestion procedure. Optimal extraction conditions for As species from four seaweed namely kombu, wakame, nori and sea lettuce were selected as a compromise between As extraction efficiency and preservation of compound identity. For most investigated samples, the use of ammonium acetate buffer as extractant and 1 h sonication in a water bath followed by HPLC-ICP-MS resulted in 40-61% of the total As to be found in the buffered aqueous extract, of which 86-110% was present as arsenosugars (glycerol sugar, phosphate sugar and sulfonate sugar for wakame and kombu and glycerol sugar and phosphate sugar for nori). The exception was sea lettuce, for which the arsenosugar fraction (glycerol sugar, phosphate sugar) only comprised 44% of the total extracted As. Interestingly, the ratio of arsenobetaine and dimethylarsinic acid to arsenosugars in sea lettuce extracts seemed higher than that for the rest of investigated samples. After in vitro gastrointestinal digestion, approximately 11-16% of the total As in the solid sample was found in the dialyzates with arsenosugars comprising 93-120% and 41% of the dialyzable As fraction for kombu, wakame, nori and sea lettuce, respectively. Moreover, the relative As species distribution in seaweed-buffered extracts and dialyzates was found to be very similar

  11. Two-dimensional HPLC coupled to ICP-MS and electrospray ionisation (ESI)-MS/MS for investigating the bioavailability in vitro of arsenic species from edible seaweed.

    Science.gov (United States)

    Garcia-Sartal, Cristina; Taebunpakul, Sutthinun; Stokes, Emma; Barciela-Alonso, María del Carmen; Bermejo-Barrera, Pilar; Goenaga-Infante, Heidi

    2012-04-01

    Edible seaweed consumption is a route of exposure to arsenic. However, little attention has been paid to estimate the bioaccessibility and/or bioavailability of arsenosugars in edible seaweed and their possible degradation products during gastrointestinal digestion. This work presents first use of combined inductively coupled plasma mass spectroscopy (ICP-MS) with electrospray ionization tandem mass spectrometry (ESI-MS/MS) with two-dimensional HPLC (size exclusion followed by anion exchange) to compare the qualitative and quantitative arsenosugars speciation of different edible seaweed with that of their bioavailable fraction as obtained using an in vitro gastrointestinal digestion procedure. Optimal extraction conditions for As species from four seaweed namely kombu, wakame, nori and sea lettuce were selected as a compromise between As extraction efficiency and preservation of compound identity. For most investigated samples, the use of ammonium acetate buffer as extractant and 1 h sonication in a water bath followed by HPLC-ICP-MS resulted in 40-61% of the total As to be found in the buffered aqueous extract, of which 86-110% was present as arsenosugars (glycerol sugar, phosphate sugar and sulfonate sugar for wakame and kombu and glycerol sugar and phosphate sugar for nori). The exception was sea lettuce, for which the arsenosugar fraction (glycerol sugar, phosphate sugar) only comprised 44% of the total extracted As. Interestingly, the ratio of arsenobetaine and dimethylarsinic acid to arsenosugars in sea lettuce extracts seemed higher than that for the rest of investigated samples. After in vitro gastrointestinal digestion, approximately 11-16% of the total As in the solid sample was found in the dialyzates with arsenosugars comprising 93-120% and 41% of the dialyzable As fraction for kombu, wakame, nori and sea lettuce, respectively. Moreover, the relative As species distribution in seaweed-buffered extracts and dialyzates was found to be very similar

  12. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  13. A non-biological method for screening active components against influenza virus from traditional Chinese medicine by coupling a LC column with oseltamivir molecularly imprinted polymers.

    Directory of Open Access Journals (Sweden)

    Ya-Jun Yang

    Full Text Available To develop a non-biological method for screening active components against influenza virus from traditional Chinese medicine (TCM extraction, a liquid chromatography (LC column prepared with oseltamivir molecularly imprinted polymer (OSMIP was employed with LC-mass spectrometry (LC-MS. From chloroform extracts of compound TCM liquid preparation, we observed an affinitive component m/z 249, which was identified to be matrine following analysis of phytochemical literatures, OSMIP-LC column on-line of control compounds and MS/MS off-line. The results showed that matrine had similar bioactivities with OS against avian influenza virus H9N2 in vitro for both alleviating cytopathic effect and hemagglutination inhibition and that the stereostructures of these two compounds are similar while their two-dimensional structures were different. In addition, our results suggested that the bioactivities of those affinitive compounds were correlated with their chromatographic behaviors, in which less difference of the chromatographic behaviors might have more similar bioactivities. This indicates that matrine is a potential candidate drug to prevent or cure influenza for human or animal. In conclusion, the present study showed that molecularly imprinted polymers can be used as a non-biological method for screening active components against influenza virus from TCM.

  14. Sedimentary deposition and reflux of phosphorus (P in the Eastern Gotland Basin and their coupling with P concentrations in the water column

    Directory of Open Access Journals (Sweden)

    Sven Hille

    2005-12-01

    Full Text Available In order to describe the role of sedimentary processes for the phosphorus (P cycle in the open Baltic Proper, P deposition and reflux were quantified for the predominately anoxic sediments of the Eastern Gotland Basin. The study is based on investigations of 53 surface sediment samples and pore water samples from 8 sediment cores. The average P deposition rate was estimated at 0.20 g ± 0.18 g -2 yr-1, the fluctuation being due to variable bulk sediment deposition rates. P refluxes were estimated by applying Fick's First Law of Diffusion. A fairly good positive correlation between sedimentary P deposition and P release was obtained. P release from sediments by diffusion exceeds net P deposition by a factor of 2. This suggests that 2/3 of the deposited gross P is recycled in the sediments and released back into the water column; only 1/3 remains in the sediment permanently. A budget calculation demonstrates that the released dissolved inorganic phosphorus (DIP accounts for the observed increase in DIP concentrations in the deep water during periods of stagnation, which is noticeable even at the surface P concentrations. Under such conditions and with the present remediation conditions it is not possible to freely manage P concentrations in the water column on short time scales.

  15. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Hung-Ju Chen

    2011-12-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method (LC-MS/MS was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (± naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals.

  16. Assessment of the Aerosol Optics Component of the Coupled WRF-CMAQ Model usingCARES Field Campaign data and a Single Column Model

    Science.gov (United States)

    The Carbonaceous Aerosols and Radiative Effects Study (CARES), a field campaign held in central California in June 2010, provides a unique opportunity to assess the aerosol optics modeling component of the two-way coupled Weather Research and Forecasting (WRF) – Community Multisc...

  17. Batch and column adsorption behaviors of Se(IV) and Te(IV) on organic and inorganic ion exchangers from HCl solutions

    Energy Technology Data Exchange (ETDEWEB)

    El-Sweify, Fatma H.; Abdel-Fattah, Alaa El-Din A.; Aly, Shorouk M.; Ghamry, Mohamed A. [Atomic Energy Authority, Cairo (Egypt). Hot Laboratories Center; El-Sheikh, Ragaa [Zagazig Univ. (Egypt). Chemistry Dept.

    2017-07-01

    Adsorption behaviors of Se(IV) and Te(IV) on the inorganic ion exchanger ceric tungstate (CeW) was studied under static and dynamic conditions and compared with the adsorption on the organic cation and anion exchangers Dowex-50X8 and AG-2X8, respectively. The radioactive isotopes {sup 75}Se and {sup 123m}Te were used to trace the respective elements. Some parameters affecting the adsorption were investigated under static conditions. In the case of batch technique the adsorption was studied from slightly acidic HCl as well as slightly alkaline media, i.e. at two pH-ranges. Se(IV) and Te(IV) were adsorbed on both the inorganic ion exchanger (CeW) and on AG-2X8, from slightly alkaline solutions. From the similarity of adsorption on both ion exchangers it was clear that (CeW) acts as an anion exchanger. Moreover, the obtained K{sub d}-values for the adsorption on (CeW) were much higher than those for the adsorption on the organic anion exchanger AG-2X8. Se(IV) was not adsorbed on Dowex-50X8 all over the studied pH-range whereas Te(IV) was slightly adsorbed. Loading and elution behaviors of Se(IV) and Te(IV) on columns of AG-2X8 and (CeW) were studied using solutions of HCl of different concentrations. Some good separation alternatives of Se(IV) and Te(IV) under certain conditions were achieved.

  18. Liquid chromatography coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry and post-column addition of metal salt solutions as a powerful tool for the metabolic profiling of Fusarium oxysporum.

    Science.gov (United States)

    Cirigliano, Adriana M; Rodriguez, M Alejandra; Gagliano, M Laura; Bertinetti, Brenda V; Godeas, Alicia M; Cabrera, Gabriela M

    2016-03-25

    Fusarium oxysporum L11 is a non-pathogenic soil-borne fungal strain that yielded an extract that showed antifungal activity against phytopathogens. In this study, reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry (API-QTOF-MS) was applied for the comprehensive profiling of the metabolites from the extract. The employed sources were electrospray (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). Post-column addition of metal solutions of Ca, Cu and Zn(II) was also tested using ESI. A total of 137 compounds were identified or tentatively identified by matching their accurate mass signals, suggested molecular formulae and MS/MS analysis with previously reported data. Some compounds were isolated and identified by NMR. The extract was rich in cyclic peptides like cyclosporins, diketopiperazines and sansalvamides, most of which were new, and are reported here for the first time. The use of post-column addition of metals resulted in a useful strategy for the discrimination of compound classes since specific adducts were observed for the different compound families. This technique also allowed the screening for compounds with metal binding properties. Thus, the applied methodology is a useful choice for the metabolic profiling of extracts and also for the selection of metabolites with potential biological activities related to interactions with metal ions. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. A Cascade Disaster Caused by Geological and Coupled Hydro-Mechanical Factors—Water Inrush Mechanism from Karst Collapse Column under Confining Pressure

    Directory of Open Access Journals (Sweden)

    Hao Li

    2017-11-01

    Full Text Available The water inrush from karst collapse column (KCC is a cascading, vicious cycle disaster caused by geological and mining activities, that can cause serious casualties and property losses. The key to preventing this risk is to study the mechanism of water inrush under confining pressure. Aiming at the investigationg the characteristics of the KCC named X1 in Chensilou mine, a series of methods, including connectivity experiments, water pressure monitoring tests in two side-walls, and numerical simulations based on plastic damage-seepage (PD-S theory have been developed. The methods are used to test the security of the 2519 mining area, the damage thickness, pore water pressure, and seepage vector in the X1. The results indicate that the X1 has a certain water blocking capacity. In addition, with the decrease of confining pressure and increase of shear stress, deviatoric stress could cause the increase of permeability, the reduction of strength, and the reduction of pore water pressure in KCC. Therefore the increased effective stress in the rock will force the rock to become more fractured. Conversely, the broken rock could cause the change of stress, and further initiate new plastic strains, damage and pore water pressure until a new equilibrium is reached. This cascading water inrush mechanism will contribute to the exploitation of deep coal resources in complex geological and hydrogeological conditions.

  20. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Wu Shuchao [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Xu Wei [State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310028, Zhejiang (China); Yang Bingcheng [School of Pharmacy, East China University of Science and Technology, Shanghai 200237 (China); Ye Mingli [Thermofisher scientific (China), Shanghai 201203 (China); Zhang Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Shentu Chao [College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China)

    2012-07-20

    Highlight: Black-Right-Pointing-Pointer An electrolytic cell including ruthenium modified titanium electrode was fabricated. Black-Right-Pointing-Pointer Ion chromatography/electrochemical derivatization/fluorescence detection was developed. Black-Right-Pointing-Pointer Strong oxidation capacity of this EC was obtained by using the Ru/Ti electrode with large surface area. - Abstract: An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH{sub 2}PO{sub 4}) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L{sup -1} to 5 mg L{sup -1} for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 {mu}g L{sup -1}, and the relative standard deviations (RSD, n = 7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  1. Non-aqueous electrolytes for isotachophoresis of weak bases and its application to the comprehensive preconcentration of the 20 proteinogenic amino acids in column-coupling ITP/CE-MS.

    Science.gov (United States)

    Kler, Pablo A; Huhn, Carolin

    2014-11-01

    Isotachophoresis (ITP) has long been used alone but also as a preconcentration technique for capillary electrophoresis (CE). Unfortunately, up to now, its application is restricted to relatively strong acids and bases as either the degree of (de)protonation is too low or the water dissociation is too high, evoking zone electrophoresis. With the comprehensive ITP analysis of all 20 proteinogenic amino acids as model analytes, we, here, show that non-aqueous ITP using dimethylsulfoxide as a solvent solves this ITP shortcoming. Dimethylsulfoxide changes the pH regime of analytes and electrolytes but, more importantly, strongly reduces the proton mobility by prohibiting hydrogen bonds and thus, the so-called Zundel-Eigen-Zundel electrical conduction mechanism of flipping hydrogen bonds. The effects are demonstrated in an electrolyte system with taurine or H(+) as terminator, and imidazole as leader together with strong acids such as oxalic and even trifluoroacetic acid as counterions, both impossible to use in aqueous solution. Mass spectrometric as well as capacitively coupled contactless conductivity detection (C(4)D) are used to follow the ITP processes. To demonstrate the preconcentration capabilities of ITP in a two-dimensional set-up, we, here, also demonstrate that our non-aqueous ITP method can be combined with capillary electrophoresis-mass spectrometry in a column-coupling system using a hybrid approach of capillaries coupled to a microfluidic interface. For this, C(4)D was optimized for on-chip detection with the electrodes aligned on top of a thin glass lid of the microfluidic chip.

  2. Application of high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for determination of chromium compounds in the air at the workplace.

    Science.gov (United States)

    Stanislawska, Magdalena; Janasik, Beata; Wasowicz, Wojciech

    2013-12-15

    The toxicity and bioavailability of chromium species are highly dependable on the form or species, therefore determination of total chromium is insufficient for a complete toxicological evaluation and risk assessment. An analytical method for determination of soluble and insoluble Cr (III) and Cr (VI) compounds in welding fume at workplace air has been developed. The total chromium (Cr) was determined by using quadruple inductively coupled plasma mass spectrometry (ICP-MS) equipped with a dynamic reaction cell (DRC(®)). Soluble trivalent and hexavalent chromium compounds were determined by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A high-speed, reversed-phase CR C8 column (PerkinElmer, Inc., Shelton, CT, USA) was used for the speciation of soluble Cr (III) and soluble Cr (VI). The separation was accomplished by interaction of the chromium species with the different components of the mobile phase. Cr (III) formed a complex with EDTA, i.e. retained on the column, while Cr (VI) existed in the solutions as dichromate. Alkaline extraction (2% KOH and 3% Na2CO3) and anion exchange column (PRP-X100, PEEK, Hamilton) were used for the separation of the total Cr (VI). The results of the determination of Cr (VI) were confirmed by the analysis of the certified reference material BCR CRM 545 (Cr (VI) in welding dust). The results obtained for the certified material (40.2±0.6 g kg(-1)) and the values recorded in the examined samples (40.7±0.6 g kg(-1)) were highly consistent. This analytical method was applied for the determination of chromium in the samples in the workplace air collected onto glass (Whatman, Ø 37 mm) and membrane filters (Sartorius, 0.8 μm, Ø 37 mm). High performance liquid chromatography with inductively coupled plasma mass spectrometry is a remarkably powerful and versatile technique for determination of chromium species in welding fume at workplace air. Crown Copyright © 2013 Published by

  3. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    Science.gov (United States)

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Dennis, Gary R; Shalliker, R Andrew

    2015-08-19

    Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. Copyright © 2015. Published by Elsevier B.V.

  5. Development and application of a new in-line coupling of a miniaturized boronate affinity monolithic column with capillary zone electrophoresis for the selective enrichment and analysis of cis-diol-containing compounds.

    Science.gov (United States)

    Espina-Benitez, Maria Betzabeth; Randon, Jérôme; Demesmay, Claire; Dugas, Vincent

    2017-04-21

    An integrated, miniaturized and fully automated system was developed for the analysis (preconcentration/purification, separation and detection) of cis-diol containing molecules in complex matrices. This innovative in-line coupling system was achieved via the in-situ and localized synthesis of a short segment of silica-based monolith at the inlet of a 75-μm inner diameter fused silica capillary. The monolithic segment was locally functionalized with an acrylamide derivative of phenylboronic acid by free radical photopolymerization within 10min of irradiation time. Efficiency of the photopolymerization reaction was followed by frontal affinity chromatography of 1,2-dihydroxybenzene (catechol) as cis-diol model solute. An active-site amount of 0.43nmolcm -1 (9.8nmolμL -1 ) of phenylboronic acid moieties was obtained, with a K d value of about 290μM close to reported value for the phenyl boronate-catechol complex. The optimal conditions of use of the miniaturized boronate affinity monolithic column (μBAMC) were determined and adapted to the in-line coupling with capillary electrophoresis. Catechol was specifically preconcentrated in a pH 8.5 phosphate buffer/MeOH (80/20, v/v) mixture. A volume up to 20 times the monolith volume can be percolated with a quantitative recovery yield. Three catecholamines were purified, preconcentrated and in-line separated. Elution from the μBAMC was performed with a small plug of acidic solution, allowing field amplified sample stacking of solutes within the plug before their in-line electrophoretic separation at pH 8.75. This unique in-line coupling was successfully used for the fully automated analysis of catecholamines neurotransmitters in urine samples, highlighting the purification efficiency of the μBAMC and the potential of such a fully integrated approach. In addition to the low sample volume required (less than 2μL), the limits of detection (LOD) accomplished with this coupling were estimated at 9.0, 9.5 and 4.8ngmL -1

  6. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  7. ( Anogeissus leiocarpus ) timber columns

    African Journals Online (AJOL)

    A procedure for designing axially loaded Ayin (Anogeissus leiocarpus) wood column or strut has been investigated. Instead of the usual categorization of columns into short, intermediate and slender according to the value of slenderness ratio, a continuous column formula representing the three categories was derived.

  8. An investigation of the applicability of the new Reillex trademark-HPQ anion exchange resin system for technetium/rhenium and uranium in the Hanford waste tanks. Milestone 4 final report

    International Nuclear Information System (INIS)

    Ashley, K.R.; Ball, J.R.; Cobb, S.L.; Adams, J.M.; Young, D.A.

    1994-01-01

    Results of the measurements of the exchange capacity and K d values for ReO 4 - on Reillex trademark-HPQ as a function of nitric acid and hydroxide concentration, temperature, and ten months time will be reported. Results of the breakthrough volumes for UO 2 2+ on Reillex-HPQ chromatography columns as a function of carbonate ion concentration in high nitrate ion concentrations and various column sizes will be reported. Individual sections of this report describe the following: the sorption behavior of ReO 4 - on the Reillex-HPQ between pH 2 and 12 in 1.00 M NaNO 3 ; results of the measurements of the K d values for ReO 4 - on Reillex-HPQ and on Reillex-HP as a function of nitrate and hydroxide ion concentrations; the sorption behavior of ReO 4 - on Reillex-HPQ resin in base with time as a variable; the results of the early attempts at determining the K d values for Na 4 UO 2 (CO 3 ) 3 on Reillex-HPQ resin; and the breakthrough of UO 2 (NO 3 ) 2 in varying nitric acid solutions on Reillex-HPQ columns

  9. Technetium removal column flow testing with alkaline, high salt, radioactive tank waste

    International Nuclear Information System (INIS)

    Blanchard, D.L. Jr.; Kurath, D.E.; Golcar, G.R.; Conradson, S.D.

    1996-01-01

    This report describes two bench-scale column tests conducted to demonstrate the removal of Tc-99 from actual alkaline high salt radioactive waste. The waste used as feed for these tests was obtained from the Hanford double shell tank AW-101, which contains double shell slurry feed (DSSF). The tank sample was diluted to approximately 5 M Na with water, and most of the Cs-137 was removed using crystalline silicotitanates. The tests were conducted with two small columns connected in series, containing, 10 mL of either a sorbent, ABEC 5000 (Eichrom Industries, Inc.), or an anion exchanger Reillex trademark-HPQ (Reilly Industries, Inc.). Both materials are selective for pertechnetate anion (TcO 4 - ). The process steps generally followed those expected in a full-scale process and included (1) resin conditioning, (2) loading, (3) caustic wash to remove residual feed and prevent the precipitation of Al(OH) 3 , and (4) elution. A small amount of Tc-99m tracer was added as ammonium pertechnetate to the feed and a portable GEA counter was used to closely monitor the process. Analyses of the Tc-99 in the waste was performed using ICP-MS with spot checks using radiochemical analysis. Technetium x-ray absorption spectroscopy (XAS) spectra of 6 samples were also collected to determine the prevalence of non-pertechnetate species [e.g. Tc(IV)

  10. Dynamic effects of diabatization in distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    The dynamic effects of diabatization in distillation columns are investigated in simulation emphasizing the heat-integrated distillation column (HIDiC). A generic, dynamic, first-principle model has been formulated, which is flexible enough to describe various diabatic distillation configurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found and control...

  11. Dynamic Effects of Diabatization in Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2012-01-01

    The dynamic eects of diabatization in distillation columns are investigated in simulation with primary focus on the heat-integrated distillation column (HIDiC). A generic, dynamic, rst-principle model has been formulated, which is exible to describe various diabatic distillation congurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found. Control...

  12. Transport properties of anion exchange membranes in contact with organic ions. Part 2. Influence of the size of the aromatic chain; Proprietes de transport de membranes echangeuses d'anions en presence d'ions organiques. Partie 2. Influence de la taille de la chaine aromatique

    Energy Technology Data Exchange (ETDEWEB)

    Delimi, R. [Lab. de Traitement des eaux, Institut de Chimie, Universite de Badji Mokhtar, Annaba (Algeria); Sandeaux, J.; Sandeaux, R.; Pourcelly, G. [Montpellier-2 Univ., Institut Europeen des Mambranes, UMR 5635, 34 (France)

    2000-12-01

    Electrodialysis (process using ion exchange membranes and an electric field) is used for the treatment of waters and industrial effluents. In this work, the physico-chemical properties of an anion exchange membrane (ADS, Solvay) were studied in aqueous solutions containing both a mineral salt (10{sup -1} M NaCl) and an organic salt (10{sup -2} to 10{sup -1} M). The organic salt was a sodium carboxylate or sulfonate bearing one or two aromatic rings. Measurements of ion exchange, water content, electric resistance, self-diffusion and electro-diffusion fluxes were performed. According to the concentration, the organic anions with highly hydrophobic character can induce a poisoning of the membrane. (authors)

  13. Solid Phase Extraction of Trace Elements in Waterand Tissue Samples on a Mini Column with Diphenylcarbazone Impregnated Nano-TiO2 and Their Determination by Inductively Coupled Plasma Optical Emission Spectrometry

    Science.gov (United States)

    Baytak, Sıtkı; Arslan, Zikri

    2015-01-01

    This study presents a simple, robust and environmentally friendly solid phase preconcentration procedure for multielement determination by inductively coupled plasma optical emission spectrometry (ICP-OES) using diphenylcarbazone (DPC) impregnated TiO2 nanopowder (n-TiO2). DPC was successfully impregnated onto n-TiO2 in colloidal solution. A number of elements, including Co(II), Cr(III), Cu(II), Fe(III), Mn(II) and Zn(II) were quantitatively preconcentrated from aqueous solutions between pH 8 and 8.5 at a flow rate of 2 mL min−1, and then eluted with 2 mL of 5% (v/v) HNO3. A mini-column packed with 0.12 g DPC impregnated n-TiO2 retained all elements quantitatively from up to 250 mL multielement solution (2.5 μg per analyte) affording an enrichment factor of 125. The limits of detection (LOD) for preconcentration of 50 mL blank solutions (n = 12) were 0.28, 0.15, 0.25, 0.22, 0.12, and 0.10 μg L−1 for Co, Cr, Cu, Fe, Mn, and Zn, respectively. The relative standard deviation (RSD) for five replicate determinations was 0.8, 3.4, 2.6, 2.2, 1.2 and 3.3% for Co, Cr, Cu, Fe, Mn and Zn, respectively, at 5 μg L−1 level. The method was validated with analysis of Freshwater (SRM 1643e) and Lobster hepatopancreas (TORT-2) certified reference materials, and then applied to the determination of the elements from tap water and lake water samples by ICP-OES. PMID:26236403

  14. Radiotoxicological analyses of {sup 239+240}Pu and {sup 241}Am in biological samples by anion-exchange and extraction chromatography: a preliminary study for internal contamination evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Ridone, S.; Arginelli, D.; Bortoluzzi, S.; Canuto, G.; Montalto, M.; Nocente, M.; Vegro, M. [Italian National Agency for New Technologies, Energy and the Environment (ENEA), Research Centre of Saluggia, Radiation Protection Institute, Saluggia, VC (Italy)

    2006-07-01

    Many biological samples (urines and faeces) have been analysed by means of chromatographic extraction columns, utilising two different resins (AG 1-X2 resin chloride and T.R.U.), in order to detect the possible internal contamination of {sup 239{sup +}}{sup 240}Pu and {sup 241}Am, for some workers of a reprocessing nuclear plant in the decommissioning phase. The results obtained show on one hand the great suitability of the first resin for the determination of plutonium, and on the other the great selectivity of the second one for the determination of americium.

  15. Application of a simple column-switching ion chromatography technique for removal of matrix interferences and sensitive fluorescence determination of acidic compounds (pharmaceutical drugs) in complex samples.

    Science.gov (United States)

    Muhammad, Nadeem; Subhani, Qamar; Wang, Fenglian; Guo, Dandan; Zhao, Qiming; Wu, Shuchao; Zhu, Yan

    2017-09-15

    This work illustrates the introduction of a simple, rugged and flexible column-switching ion chromatography (IC) technique for an automated on-line QuEChERS extracted samples extracts washing followed by sensitive fluorescence (FLD) determination of five acidic pharmaceutical drugs namely; clofibric acid (CLO), ibuprofen (IBU), aspirin (ASP), naproxen (NAP) and flurobrofen (FLU) in three complex samples (spinach, apple and hospital sewage sludge). An old anion exchange column IonPac ® AS11-HC was utilized as a pre-treatment column for on-line washing of inorganic and organic interferences followed by isocratic separation of five acidic drugs with another anion exchange IonPac ® AS12A analytical column by exploiting the column-switching technique. This novel method exhibited good linearity with correlation coefficients (r 2 ) for all drugs were in the range 0.976-0.996. The limit of detection and quantification of all five acidic drugs were in the range 0.024μg/kg to 8.70μg/kg and 0.082μg/kg to 0.029mg/kg, respectively, and better recoveries in the range 81.17-112.5% with percentage relative standard deviations (RSDs) less than 17.8% were obtained. This on-line sample pre-treatment method showed minimum matrix effect in the range of 0.87-1.25 except for aspirin. This simple rugged and flexible column-switching system required only 28min for maximum elimination of matrices and interferences in three complex samples extracts, isocratic separation of five acidic drugs and for the continuous regeneration of pre-treatment column prior to every subsequent analysis. Finally, this simple automated IC system was appeared so rugged and flexible, which can eliminate and wash out most of interference, impurities and matrices in complex samples, simply by adjusting the NaOH and acetonitrile concentration in washing mobile phase with maximum recoveries of acidic analytes of interest. Copyright © 2017. Published by Elsevier B.V.

  16. Separation of mercury(II), methylmercury and phenylmercury by micellar high-performance liquid chromatography on short columns

    International Nuclear Information System (INIS)

    Hutta, M.; Megova, S.; Halko, R.

    1998-01-01

    Three environmentally and agrochemically important mercury species: methylmercury, phenylmercury and mercury(II) are separated within 4 minutes as bromocomplexes by micellar liquid chromatography using very short reversed-phase (RP) C18 columns (up to 30 mm). The micellar mobile phase containing 0.05M cetyltrimethylammonium bromide (CTMA + Br - ), 1% (v/v) 2-propanol, 0.001M cyclohexylenediaminetetraacetic acid (DCTA) and sulfuric acid (pH 2) showed good selectivity in mixed reversed-phase and anion-exchange mode. The above mentioned separation order in which organomercurials are eluted far behind the void volume of the column, but before the mercury(II) peak is advantageous in all instances where mercury(II) is present in real samples in great excess. Environmental and agrochemical samples contain humic material which does not interfere in this particular system. The low cost photometric detection at 500 nm after post-column derivatization by CTMA + Br - micellized dithizone is almost free from interferences and enables detection limits at the 1-3 ng level (e.g., 0.1 ppm Hg) for 20 μl samples. (author)

  17. Simultaneous determination of inorganic and organic anions by ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Soon; Joe, Ki Soo; Han, Sun Ho; Park, Soon Dal; Choi, Kwang Soon

    1999-06-01

    Four methods were investigated for the simultaneous determination of several inorganic and organic anions in aqueous solution by ion chromatography. The first is two columns coupled system. The second is the gradient elution system with an anion exchange column. The third is the system with a mixed-mode stationary phase. The fourth is the system with an anion exchange column and the eluant of low conductivity without ion suppressor. The advantages and disadvantages of individual systems were discussed. The suitable methods were proposed for the application to the samples of the nuclear power industry and the environment. (author)

  18. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  19. APPLICATION OF COLUMN EXTRACTION METHOD FOR IMPURITIES ANALYSIS ON HB-LINE PLUTONIUM OXIDE IN SUPPORT OF MOX FEED PRODUCT SPECIFICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M.; Diprete, D.; Wiedenman, B.

    2012-03-20

    The current mission at H-Canyon involves the dissolution of an Alternate Feedstocks 2 (AFS-2) inventory that contains plutonium metal. Once dissolved, HB-Line is tasked with purifying the plutonium solution via anion exchange, precipitating the Pu as oxalate, and calcining to form plutonium oxide (PuO{sub 2}). The PuO{sub 2} will provide feed product for the Mixed Oxide (MOX) Fuel Fabrication Facility, and the anion exchange raffinate will be transferred to H-Canyon. The results presented in this report document the potential success of the RE resin column extraction application on highly concentrated Pu samples to meet MOX feed product specifications. The original 'Hearts Cut' sample required a 10000x dilution to limit instrument drift on the ICP-MS method. The instrument dilution factors improved to 125x and 250x for the sample raffinate and sample eluent, respectively. As noted in the introduction, the significantly lower dilutions help to drop the total MRL for the analyte. Although the spike recoveries were half of expected in the eluent for several key elements, they were between 94-98% after Nd tracer correction. It is seen that the lower ICD limit requirements for the rare earths are attainable because of less dilution. Especially important is the extremely low Ga limit at 0.12 {mu}g/g Pu; an ICP-MS method is now available to accomplish this task on the sample raffinate. While B and V meet the column A limits, further development is needed to meet the column B limits. Even though V remained on the RE resin column, an analysis method is ready for investigation on the ICP-MS, but it does not mean that V cannot be measured on the ICP-ES at a low dilution to meet the column B limits. Furthermore, this column method can be applicable for ICP-ES as shown in Table 3-2, in that it trims the sample of Pu, decreasing and sometimes eliminating Pu spectral interferences.

  20. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  1. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  2. Nuclear reactor control column

    International Nuclear Information System (INIS)

    Bachovchin, D.M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest crosssectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor

  3. Novel on-line column extraction apparatus coupled with binary peak focusing for high-performance liquid chromatography determination of rifampicin in human plasma: a strategy for therapeutic drug monitoring.

    Science.gov (United States)

    Li, Wei; Peng, Min; Long, Minghui; Qiu, Ximin; Yang, Liping

    2014-12-01

    In order to develop a method that is completely suitable for the routine therapeutic drug monitoring, a sensitive and fully automated on-line column extraction apparatus in combination with high-performance liquid chromatography allowing binary peak focusing was developed and validated for the determination of rifampicin in human plasma. Rifapentine was used as an internal standard. The analytical cycle started with the injection of 100 μL of the sample pretreated by protein precipitation in a Venusil SCX extraction column. After the elution, the analytes were transferred and concentrated in an Xtimate C18 trap column. Finally, the trapped analytes were separated by an Xtimate C18 analytical column and were analyzed by an ultraviolet detector at 336 nm. With this new strategy, continuous on-line analysis of the compounds was successfully performed. The method showed excellent performance for the analysis of rifampicin in plasma samples, including calibration curve linearity (All r were larger than 0.9996), sensitivity (lowest limit of quantification was 0.12 μg/mL), method accuracy (within 6.6% in terms of relative error), and precision (relative standard deviations of intra- and interday precision were less than 7.8%). These results demonstrated that the simple, reliable, and automatic method based on on-line column extraction and binary peak focusing is a promising approach for therapeutic drug monitoring in complex biomatrix samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A novel application of methacrylate based short monolithic columns: concentrating Potato spindle tuber viroid from water samples.

    Science.gov (United States)

    Ruščić, Jelena; Gutiérrez-Aguirre, Ion; Urbas, Lidija; Kramberger, Petra; Mehle, Nataša; Škorić, Dijana; Barut, Miloš; Ravnikar, Maja; Krajačić, Mladen

    2013-01-25

    Potato spindle tuber viroid (PSTVd) is the causal agent of a number of agriculturally important diseases. It is a single-stranded, circular and unencapsidated RNA molecule with only 356-360 nucleotides and no coding capacity. Because of its peculiar structural features, it is very stable ex vivo and it is easily transmitted mechanically by contaminated hands, tools, machinery, etc. In this work, we describe the development and optimization of a method for concentrating PSTVd using Convective Interaction Media (CIM) monolithic columns. The ion-exchange chromatography on diethylamine (DEAE) monolithic analytical column (CIMac DEAE-0.1 mL) resulted in up to 30% PSTVd recovery whilst the hydrophobic interaction chromatography on C4 monolithic analytical column (CIMac C4-0.1 mL) improved it up to 60%. This was due to the fact that the binding of the viroid to the C4 matrix was less strong than to the highly charged anion-exchange matrix and could be easier and more completely eluted under the applied chromatographic conditions. Based on these preliminary results, a C4 HLD-1 (High Ligand Density) 1 mL monolithic tube column was selected for further experiments. One-litre-water samples were mixed with different viroid quantities and loaded onto the column. By using reverse transcription quantitative polymerase chain reaction (RT-qPCR), the viroid RNA was quantified in the elution fraction (≈5 mL) indicating that 70% of the viroid was recovered and concentrated by at least two orders of magnitude. This approach will be helpful in screening irrigation waters and/or hydroponic systems' nutrient solutions for the presence of even extremely low concentrations of PSTVd. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Mush Column Magma Chambers

    Science.gov (United States)

    Marsh, B. D.

    2002-12-01

    of the system, coupled with these processes, define the fundamental compositional and dynamic diversity of the Mush Column. In some ways it functions like a complex musical instrument. Entrainment, transport, and sorting of cumulate crystals as a function of repose time and the local flux intensity also contribute to the basic compositional diversity of the system. In the Ferrar dolerite system, about 104 km3 of dolerite is distributed throughout a fir-tree like stack of 4 or 5 extensive 300-750 m thick sills. The lowest sill contains a vast tongue of entrained orthopyroxene (opx) cumulates emplaced with the sill itself. The bulk sill composition varies from 20 pc MgO in the tongue center to 7 pc in the leading tip and margins of the sill, which itself defines the compositional spectrum of the whole complex and is remarkably similar to that exhibited by Hawaii. Relative sorting of large (1-50 mm) opx and small (1-3 mm) plagioclase due to kinetic sieving in the tongue produces pervasive anorthosite stringers. Through local ponding this has culminated in the formation of a small, well-formed layered intrusion consisting of alternating layers of orthopyroxenite and anorthosite. Upwards in the system the sills become progressively depleted in MgO and temporally and spatially contiguous flood basalts are low MgO tholeiites with no sign of opx cumulates. The size, extent, number of sills, and the internal structure of individual sills suggest a rhythm of injection similar to that of volcanic episodes. The continued horizontal stretching of a system of this type would lead to processes as recorded by ophiolites, and the repeated injection into a single reservoir would undoubtedly lead to a massive layered intrusion or to a series of high-level nested plutons.

  6. Buckling of liquid columns

    NARCIS (Netherlands)

    Habibi, M.; Rahmani, Y.; Bonn, D.; Ribe, N.M.

    2010-01-01

    Under appropriate conditions, a column of viscous liquid falling onto a rigid surface undergoes a buckling instability. Here we show experimentally and theoretically that liquid buckling exhibits a hitherto unsuspected complexity involving three different modes—viscous, gravitational, and

  7. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  8. [Plant drugs with residues of organochlorine compounds. 2. Identification of residues of DDT and its analogs by comparison of gas chromatography on packed and capillary columns and GC/MS coupling].

    Science.gov (United States)

    Benecke, R; Brotka, J; Wijsbeek, J; Franke, J P; Bruins, A P; de Zeeuw, R A

    1986-07-01

    For the GC analysis of DDT isomers and metabolites in extracts of Flores Chamomillae end Radix Valerianae the separation on a packed QF-1/OV-17 column was compared with various capillary columns of the CP-Sil type. Identification of the individual compounds could be achieved by comparing the retention behavior, chemical transformation of DDT and DDE, as well as by capillary GC-MS using single ion monitoring of substance-characteristic ion mass. In this way, residues of p,p'-DDT, o,p'-DDE and p,p'-TDE could be identified.

  9. [Analysis of residues of organochlorine compounds in plant drugs. 3. Identification of residues of polychlorobiphenyl compounds by comparison of gas chromatography on packed and capillary columns and GCMS coupling].

    Science.gov (United States)

    Benecke, R; Brotka, J; Wijsbeek, J; Franke, J P; Bruins, A P; de Zeeuw, R A

    1988-02-01

    The identification of residues of polychlorinated biphenyls in a test sample of Flores Chamomillae could be achieved by the retention behavior at gas chromatographic analyses on packed and capillary columns compared with reference standard Clophen A 60, respectively as well as well by capillary GC/MS using single ion monitoring of substance-characteristic ion mass.

  10. Five points on columns

    Directory of Open Access Journals (Sweden)

    Kathleen S Rockland

    2010-06-01

    Full Text Available Abstract “Column,” like “gene,” has both conceptual and linguistic shortcomings. The simple question “what is a column” is not easy to answer and the word itself is not easy to replace. In the present article, I have selected five points, in no way comprehensive or canonical, but which may nevertheless serve as a prompt and aid for further discussions and reevaluation. These are: that anatomical columns are not solid structures, that they are part of locally interdigitating systems, that any delimited column also participates in a widely distributed network, that columns are not an obligatory cortical feature, and that columns (as “modules” occur widely in the brain in non-cortical structures. I focus on the larger scale macrocolumns, mainly from an anatomical perspective. My position is that cortical organization is inherently dynamic and likely to incorporate multiple processing styles. One can speculate that the distributed mappings within areas like piriform cortex may resemble at least one mode of neocortical processing strategy.

  11. Decoding the Pantheon Columns

    Directory of Open Access Journals (Sweden)

    Gerd Grasshoff

    2014-06-01

    Full Text Available The goal of this study has been to reconstruct the design principles underlying the construction of the Pantheon’s portico columns as well as to demonstrate how digital investigation methods and models can be used to improve our understanding of ancient architectural knowledge. Thanks to the data of the Bern Digital Pantheon Model, a synthesis of all the scanned surface points obtained during a digitization campaign of the Karman Center for Advanced Studies in the Humanities of the University of Bern in 2005, we have been able to determine empirically the column profiles of the portico with unprecedented precision. A second stage of our investigation involved explaining the profile of the column shafts by a construction model that takes into account the parameters recommended by Vitruvius and design methods such as those that can be found in the construction drawings discovered at Didyma. Our analysis shows that the design principles of the portico’s columns can be successfully reconstructed, and has led to the surprising result that at least two different variants of a simple circle construction were used. Finally, we have been able to deduce from the distribution of the different profile types among the columns that the final profiles were designed and executed in Rome.

  12. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  13. Slender CRC Columns

    OpenAIRE

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which current design guides can be used. The columns tested had a slenderness varying from 1.11 to 12.76 and a reinforcement ratio (area of rebar to area of concrete) ranging from 0 to 8.8 %. A total of 77 te...

  14. Practical column design guide

    CERN Document Server

    Nitsche, M

    2017-01-01

    This book highlights the aspects that need to be considered when designing distillation columns in practice. It discusses the influencing parameters as well as the equations governing them, and presents several numerical examples. The book is intended both for experienced designers and for those who are new to the subject.

  15. Columns in Clay

    Science.gov (United States)

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  16. Steel column base classification

    OpenAIRE

    Jaspart, J.P.; Wald, F.; Weynand, K.; Gresnigt, A.M.

    2008-01-01

    The influence of the rotational characteristics of the column bases on the structural frame response is discussed and specific design criteria for stiffness classification into semi-rigid and rigid joints are derived. The particular case of an industrial portal frame is then considered. Peer reviewed

  17. European Analytical Column

    DEFF Research Database (Denmark)

    Karlberg, B.; Grasserbauer, M.; Andersen, Jens Enevold Thaulov

    2009-01-01

    The European Analytical Column has once more invited a guest columnist to give his views on various matters related to analytical chemistry in Europe. This year, we have invited Professor Manfred Grasserbauer of the Vienna University of Technology to present some of the current challenges for Eur...

  18. Pressure-dependent boron isotopic fractionation observed by column chromatography

    Science.gov (United States)

    Musashi, M.; Oi, T.; Matsuo, M.; Nomura, M.

    2007-12-01

    Boron isotopic fractionation factor ( S ) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25°C, using 0.1 mmol/L boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at atmospheric pressure at 25°C with the boron concentration of 10 mmol/L, but were larger than the values at the same condition with much higher concentration of 100 and 501 mmol/L, indicating that borate-polymerization reducing the isotopic fractionation was negligible. However, calculations based on the theory of isotope distribution between two phases estimated that 21% (5MPa) and 47% (17MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)3-form, instead of in the four-coordinated B(OH)4--form, at high pressures even with the very diluted solution. We discussed this discrepancy by introducing (1) hydration or (2) a partial molar volume difference between isotopic molecules. It was inferred that borate ions were partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Alternatively, it was likely that the S value decreased with increasing pressure, because the difference of the partial isotopic molar volumes between 10B(OH)3 and 11B(OH)3 was larger than that between 10B(OH)4- and 11B(OH)4-. If either will be the case, the influence of a pressure upon the isotope effect may not be negligible for boron isotopic exchange equilibrium. This knowledge is crucial for the principle of the boron isotopic pH-metry reconstructing a chemical variation at the paleo-deep oceanic environment where the early life may have been evolved.

  19. Nine Words - Nine Columns

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2016-01-01

    of computational and mechanical processes towards an anesthetic. Each team received a single word, translating and evolving that word first into a double-curved computational surface, next a ruled computational surface, and then a physically shaped foam mold via a 6-axis robot. The foam molds then operated...... as formwork for the shaping of wood veneer. The resulting columns ‘wear’ every aspect of this design pipeline process and display the power of process towards an architectural resolution....

  20. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    in standard fire conditions. The tests showed good correlation between test results and results calculated according to established deisgn guides. The fire tests demonstrate that the load capacity of slender columns can be reduced very quickly due to thermal stresses and a reduction of stiffness - also...... in cases where temperature at the rebar is still relatively low. However, guidelines for achieving acceptable fire resistance can be determined based on the test results....

  1. Nine Words - Nine Columns

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2016-01-01

    This book records the efforts of a one-week joint workshop between Master students from Studio 2B of Arkitektskolen Aarhus and Master students from the Harbin Institute of Technology in Harbin, China. The workshop employed nine action words to instigate team-based investigation into the effects o...... as formwork for the shaping of wood veneer. The resulting columns ‘wear’ every aspect of this design pipeline process and display the power of process towards an architectural resolution....

  2. Monolithic column in gas chromatography.

    Science.gov (United States)

    Kurganov, A

    2013-05-02

    Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Mechanical Characterization of Anion Exchange Membranes Under Controlled Environmental Conditions

    Science.gov (United States)

    2015-05-11

    supporting textiles and test the mechanical properties. Even though their films were only 10 microns, the SER fixture was used by applying double stick tape...aramid and stainless steel. The authors conclude that supporting textile has a large impact on mechanical properties due to the difference in...Elongation) are depicted. 2.2 Conductivity Ionic conductivity was measured by electrochemical impedance spectroscopy using a four- electrode in-plane

  4. Thin Robust Anion Exchange Membranes for Fuel Cell Applications

    Science.gov (United States)

    2014-01-01

    polymer concentration jumps between two co-existing phases. In the latter case, the dilute phase usually arranges into a slab centered around the...we expect a more encouraging durability in the alkaline condition by adding three 2,4,6- trimethoxyphenyl groups on a high basicity phosphine. The

  5. Evaluation of some anionic exchange resins as potential tablet ...

    African Journals Online (AJOL)

    The effect of resin concentration and compression force on the properties of tablets using the selected resin was investigated. In addition, the disintegrant efficacy of the selected resin in the tablet formulations containing either a basic drug, e.g., dextromethorphan hydrobromide (DMP), or an acidic drug, e.g., diclofenac ...

  6. Anion-exchange resin-based desulfurization process. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, A C; Dharmapurikar, R; Strevel, S D

    1994-01-01

    The following investigations were performed: (1) batch mode screening of eleven(11) commercially available resins and selection of three candidate resins for further evaluation in a fixed-bed setup. (2) Process variables study using three candidate resins in the fixed-bed setup and selection of the ``best`` resin for process economics development. (3) Exhaustion efficiency and solution concentration were found to be inversely related necessitating a trade-off between the resin cost versus the cost of evaporation/concentration of ensuing effluents. (4) Higher concentration of the HCO{sub 3}{sup {minus}} form of active sites over less active CO{sub 3}{sup 2{minus}} form of sites in the resin was believed to be the main reason for the observed increase in the equilibrium capacity of the resin at an elevated static CO{sub 2}-pressure. This Increase in capacity was found to level off around 80--120 psig range. The increase in CO{sub 2}-pressure, however, did not appear to affect the overall ion-exchange kinetics. (5) In the fixed-bed mode, the solution concentration was found to affect the equilibrium capacity of candidate resins. Their relationship was well satisfied by the Langmuir type non-linear equilibrium isotherm. Alternatively, the effect of solution concentration on overall ion-exchange kinetics varied from resin to resin. (6) Product inhibition effect on the resin was observed as an initial increase followed by a significant decrease in the resin`s equilibrium capacity for SO{sub 4}{sup 2{minus}} as the HCO{sub 3}{sup {minus}}/SO{sub 4}{sup 2{minus}} molar ratio in the solution was increased from 0 to 1.0. This ratio, however, did not affect the overall ion-exchange kinetics.

  7. Polypropylene based anion exchange fiber for enrichment and ...

    African Journals Online (AJOL)

    The fibers were soaked in 2 M sodium hydroxide sodium hydroxide solution for activation and were washed with distilled water at least thirty times until neutral for regeneration, The saturated capacity of the fiber for In(III) was 1.32 mg·g-1. The activation energy (Ea) of the fiber adsorption In(III) was 89.3 kJ·mol-1. The method ...

  8. Determination of trace inorganic anions in weak acids by single-pump column-switching ion chromatography.

    Science.gov (United States)

    Zhu, Haibao; Chen, Huadong; Zhong, Yingying; Ren, Dandan; Qian, Yaling; Tang, Hongfang; Zhu, Yan

    2010-08-01

    Ion chromatography has been proposed for the determination of three common inorganic anions (chloride, nitrate, and sulfate) in nine weak acids (tartaric acid, citric acid, formic acid, acetic acid, metacetonic acid, butyric acid, butanedioic acid, hexafluorophosphoric acid, and salicylic acid) using a single pump, two valves, a single eluent, and a single conductivity detector. The present system uses ion exclusion, concentrator, and anion-exchange columns connected in series via 6-port and 10-port valves in a Dionex ICS-2100 ion chromatograph. The valves were switched for the determination of three inorganic anions from weak acids in a single chromatographic run. Sample matrices of weak acids with a series of concentrations can be investigated. Complete separations of the previously mentioned anions are demonstrated within 40 min. Under the optimum conditions, the relative standard deviation values ranged from 1.3 to 3.8%. The detection limits of the three inorganic anions (S/N = 3) were in the range of 0.3-1.7 microg/L. The recoveries were in the range of 75.2-117.6%. With this system, automation for routine analysis, short analysis time, and low cost can be achieved.

  9. Liquid Chromatography with Post-Column Reagent Addition of Ammonia in Methanol Coupled to Negative Ion Electrospray Ionization Tandem Mass Spectrometry for Determination of Phenoxyacid Herbicides and their Degradation Products in Surface Water

    Directory of Open Access Journals (Sweden)

    Michele L. Etter

    2010-02-01

    Full Text Available A new liquid chromatography (LC-negative ion electrospray ionization (ESI–tandem mass spectrometry (MS/MS method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy ace- tic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxybutyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2- methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE with a polymeric sorbent and analyzed with LC ESI- with selected reaction monitoring (SRM using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 × 4.6 mm i.d., 1.8 µm with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the deg- radation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD were between 1 and 15 ng L-1 and method detection limits (MDL with strict criteria requiring

  10. Column: Every Last Byte

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-06-01

    Full Text Available Inheritance powder is the name that was given to poisons, especially arsenic, that were commonly used in the 17th and early 18th centuries to hasten the death of the elderly. For most of the 17th century, arsenic was deadly but undetectable, making it nearly impossible to prove that someone had been poisoned. The first arsenic test produced a gas—hardly something that a scientist could show to a judge. Faced with a growing epidemic of poisonings, doctors and chemists spent decades searching for something better.(see PDF for full column

  11. Synthesis of novel chitosan resin derivatized with serine moiety for the column collection/concentration of uranium and the determination of uranium by ICP-MS

    International Nuclear Information System (INIS)

    Oshita, Koji; Oshima, Mitsuko; Gao Yunhua; Lee, Kyue-Hyung; Motomizu, Shoji

    2003-01-01

    A chitosan resin derivatized with serine moiety (serine-type chitosan) was newly developed by using the cross-linked chitosan as a base material. The adsorption behavior of trace amounts of metal ions on the serine-type chitosan resin was systematically examined by packing it in a mini-column, passing a metal solution through it and measuring metal ions in the effluent by ICP-MS. The resin could adsorb a number of metal cations at pH from neutral to alkaline region, and several oxoanionic metals at acidic pH region by an anion exchange mechanism. Uranium and Cu could be adsorbed selectively at pH from acidic to alkaline region by a chelating mechanism; U could be adsorbed quantitatively even at pH 3-4. Uranium adsorbed on the resin was easily eluted with 1 M nitric acid: the preconcentration (5-, 10-, 50- and 100-fold) of U was possible. The column treatment method was used prior to the ICP-MS measurement of U in natural river, sea and tap waters; R.S.D. were 2.63, 1.13 and 1.37%, respectively. Uranium in tap water could be determined by 10-fold preconcentration: analytical result was 1.46±0.02 ppt. The resin also was applied to the recovery of U in sea water: the recovery tests for artificial and natural sea water were 97.1 and 93.0%, respectively

  12. Covalently bonded ionic liquid onto cellulose for fast adsorption and efficient separation of Cr(VI): Batch, column and mechanism investigation.

    Science.gov (United States)

    Dong, Zhen; Zhao, Long

    2018-06-01

    Combining the advantages of both cellulose and ionic liquid, ionic liquid functionalized cellulose (ILFC) as adsorbent was prepared through radiation grafting glycidyl methacrylate onto cellulose microsphere following by reaction with ionic liquid 1-aminopropyl-3-methyl imidazolium nitrate. Its adsorption properties towards Cr(VI) were investigated in batch and column experiments. In batch experiments, the adsorption kinetics was well fitted with pseudo-second-order mode with equilibrium time of 2 h and the adsorption capacity reached 181.8 mg/g at pH 2 calculated from Langmuir model. In fixed column, both Yoon-Nelson and Thomas models gave satisfactory fit to experimental data and breakthrough curves, and equilibrium adsorption capacity calculated by Thomas model was 161.0 mg/g. Moreover, ILFC exhibited high selectivity towards Cr(VI) even in synthetic chrome-plating wastewater. Besides, adsorption/desorption test revealed ILFC can be regenerated and reused several times without obvious decrease in adsorbed amount. The adsorption process was demonstrated to anion exchange-reduction mechanism via XPS analysis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  14. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  15. Regeneration of pilot-scale ion exchange columns for hexavalent chromium removal.

    Science.gov (United States)

    Korak, Julie A; Huggins, Richard; Arias-Paic, Miguel

    2017-07-01

    Due to stricter regulations, some drinking water utilities must implement additional treatment processes to meet potable water standards for hexavalent chromium (Cr(VI)), such as the California limit of 10 μg/L. Strong base anion exchange is effective for Cr(VI) removal, but efficient resin regeneration and waste minimization are important for operational, economic and environmental considerations. This study compared multiple regeneration methods on pilot-scale columns on the basis of regeneration efficiency, waste production and salt usage. A conventional 1-Stage regeneration using 2 N sodium chloride (NaCl) was compared to 1) a 2-Stage process with 0.2 N NaCl followed by 2 N NaCl and 2) a mixed regenerant solution with 2 N NaCl and 0.2 N sodium bicarbonate. All methods eluted similar cumulative amounts of chromium with 2 N NaCl. The 2-Stage process eluted an additional 20-30% of chromium in the 0.2 N fraction, but total resin capacity is unaffected if this fraction is recycled to the ion exchange headworks. The 2-Stage approach selectively eluted bicarbonate and sulfate with 0.2 N NaCl before regeneration using 2 N NaCl. Regeneration approach impacted the elution efficiency of both uranium and vanadium. Regeneration without co-eluting sulfate and bicarbonate led to incomplete uranium elution and potential formation of insoluble uranium hydroxides that could lead to long-term resin fouling, decreased capacity and render the resin a low-level radioactive solid waste. Partial vanadium elution occurred during regeneration due to co-eluting sulfate suppressing vanadium release. Waste production and salt usage were comparable for the 1- and 2-Stage regeneration processes with similar operational setpoints with respect to chromium or nitrate elution. Published by Elsevier Ltd.

  16. Column chromatographic boron isotope separation at 5 and 17 MPa with diluted boric acid solution.

    Science.gov (United States)

    Musashi, Masaaki; Oi, Takao; Matsuo, Motoyuki; Nomura, Masao

    2008-08-01

    Boron isotopic fractionation factor (S) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25 degrees C, using 0.1 mM boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at the atmospheric pressure at 25 degrees C with the boron concentration of 10mM, but were larger than the values under the same condition with much higher concentration of 100 and 501 mM. Calculations based on the theory of isotope distribution between two phases estimated that 21% (5 MPa) and 47% (17 MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)(3)-form, instead of in the four-coordinated B(OH)(4)-form, at high pressures even with a very diluted boric acid solution. We discussed the present results by introducing (1) hydration and (2) a partial molar volume difference between isotopic molecules. Borate may have been partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Instead, it may be possible that the difference in the isotopic partial molar volume difference between B(OH)(3) and B(OH)(4)(-) caused the S value to decrease with increasing pressure.

  17. Column: File Cabinet Forensics

    Directory of Open Access Journals (Sweden)

    Simson Garfinkel

    2011-12-01

    Full Text Available Researchers can spend their time reverse engineering, performing reverse analysis, or making substantive contributions to digital forensics science. Although work in all of these areas is important, it is the scientific breakthroughs that are the most critical for addressing the challenges that we face.Reverse Engineering is the traditional bread-and-butter of digital forensics research. Companies like Microsoft and Apple deliver computational artifacts (operating systems, applications and phones to the commercial market. These artifacts are bought and used by billions. Some have evil intent, and (if society is lucky, the computers end up in the hands of law enforcement. Unfortunately the original vendors rarely provide digital forensics tools that make their systems amenable to analysis by law enforcement. Hence the need for reverse engineering.(see PDF for full column

  18. Buckling of a holey column.

    Science.gov (United States)

    Pihler-Puzović, D; Hazel, A L; Mullin, T

    2016-09-14

    We report the results from a combined experimental and numerical investigation of buckling in a novel variant of an elastic column under axial load. We find that including a regular line of centred holes in the column can prevent conventional, global, lateral buckling. Instead, the local microstructure introduced by the holes allows the column to buckle in an entirely different, internal, mode in which the holes are compressed in alternate directions, but the column maintains the lateral reflection symmetry about its centreline. The internal buckling mode can be accommodated within a smaller external space than the global one; and it is the preferred buckling mode over an intermediate range of column lengths for sufficiently large holes. For very short or sufficiently long columns a modification of the classical, global, lateral buckling is dominant.

  19. Low-level bromate analysis in drinking water by ion chromatography with optimized suppressed conductivity cell current followed by a post-column reaction and UV/Vis detection.

    Science.gov (United States)

    Fotsing, Marcellin; Barbeau, Benoit; Prevost, Michele

    2011-01-01

    In the present work, a high capacity anion exchange column was used to efficiently and simultaneously separate traces of oxyhalide disinfection byproducts (DBP) anions and bromide by an ion chromatography system followed by a post-column reaction (PCR). The PCR generates in situ hydroiodic (HI) acid from the excess of potassium iodate that combines with bromate from the column effluent to form the triiodide anion detectable by UV/Vis absorbance at 352 nm. The suppressed conductivity cell current was optimized at 70 mA, with a flow rate of 1.0 mL/min and a 9 mM carbonate eluent. Its performance was investigated on a trace-level determination of bromate in ozonated municipal and bottled drinking water. Based on ozonated municipal drinking water matrix, the method detection limit of 0.27 μg BrO(-)(3)/L was evaluated with the Method Quantification Limit (MQL) of 0.89 μg BrO(-)(3)/L. However, in ultrapure water, a MDL of 0.015 μg BrO(-)(3)/L and a MRL of 0.052 μg BrO(-)(3)/L were achieved. The recovery for spiked municipal samples was in the range of 90%-115%.

  20. Cortical columns for quick brains

    OpenAIRE

    Stoop, Ralph L.; Saase, Victor; Wagner, Clemens; Stoop, Britta; Stoop, Ruedi

    2012-01-01

    It is widely believed that the particular wiring observed within cortical columns boosts neural computation. We use rewiring of neural networks performing real-world cognitive tasks to study the validity of this argument. In a vast survey of wirings within the column we detect, however, no traces of the proposed effect. It is on the mesoscopic inter-columnar scale that the existence of columns - largely irrespective of their inner organization - enhances the speed of information transfer and ...

  1. Preparation of a hyper-cross-linked polymer monolithic column and its application to the sensitive determination of genomic DNA methylation.

    Science.gov (United States)

    Chen, Ming-Luan; Liu, Yu-Li; Xing, Xi-Wen; Zhou, Xiang; Feng, Yu-Qi; Yuan, Bi-Feng

    2013-01-14

    A hyper-cross-linked polymer monolithic column, poly(methacrylatoethyl trimethyl ammonium-co-vinylbenzene chloride-co-divinylbenzene) (MATE-co-VBC-co-DVB) with phenyl and quaternary ammonium groups was successfully prepared in the current study. The prepared monolith possesses large specific surface area, narrow mesopore size distribution and high column efficiency. The poly(MATE-co-VBC-co-DVB) monolithic column was demonstrated to have strong anion exchange/reversed-phase (SAX/RP) mixed-mode retention for analytes on capillary liquid chromatography (cLC). By using this monolithic column, we developed a rapid and sensitive method for the detection of DNA methylation. Our results showed that six nucleobases (adenine, guanine, cytosine, thymine, uracil, and 5-methylcytosine (5-mC)) can be baseline separated within 15 min by electrostatic repulsion and hydrophobic interactions between nucleobases and the monolithic stationary phase. The limit of detection (LOD, signal/noise = 3) of 5-mC is 0.014 pmol and endogenous 5-mC can be distinctly detected by using only 10 ng genomic DNA, which is comparable to that obtained by mass spectrometry analysis. Furthermore, by using the method developed here, we found that DNA methylation inhibitor 5-azacytidine (5-aza-C) and 5-aza-2'-deoxycytidine (5-aza-CdR) could induce a significant decrease of genome-wide DNA methylation in human lung carcinoma cells (A549) and cervical carcinoma cells (HeLa). Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Coupling of an electrodialyzer with inductively coupled plasma mass spectrometry for the on-line determination of trace impurities in silicon wafers after surface metal extraction.

    Science.gov (United States)

    Chang, I-long; Hsu, I-hsiang; Yang, Mo-hsiung; Sun, Yun-chang

    2010-02-19

    Understanding the properties that determine the distribution and behavior of trace impurities in Si wafers is critical to defining and controlling the performance, reliability, and yields of integrated microelectronic devices. It remains, however, an intrinsically difficult task to determine trace impurities in Si because of the minute concentrations and extremely high levels of matrix involved. In this study, we used an electrodialyzer for the simultaneous on-line removal of the silicate and acid matrices through the neutralization of the excessive hydrogen ion and selectively separation of acid and silicate ions by the combination of electrode reaction as a source of hydroxide ions with the anion exchange membrane separation. To retain the analyte ions in the sample stream, we found that the presence of moderate amounts of nitric acid and hydrazine were necessary to improve the retention efficiency, not only for Zn(2+), Ni(2+), Cu(2+), and Co(2+) ions but also for CrO(4)(2-) ion. Under the optimized conditions, the interference that resulted from the sample matrix was suppressed significantly to provide satisfactory analytical signals. The precision of this method was ca. 5% when we used an electrodialyzer equipped with an anion exchange membrane to remove the sample matrix prior to performing inductively coupled plasma mass spectrometry (ICP-MS); the good agreement between the data obtained using our proposed method and those obtained using a batchwise wet chemical technique confirmed its accuracy. Our method permits the determination of Zn, Ni, Cu, Co, and Cr in Si wafers at detection limits within the range from 2.2 x 10(15) to 9.0 x 10(15) atoms cm(-3). Copyright 2009 Elsevier B.V. All rights reserved.

  3. Study of the leaching of heavy metals from waste water sludge and incinerator's ash, using coupled thermostated columns and DTPA as complex agent; Estudio de la extraccion de metales pesados de lodos y cenizas de aguas residuales usando columnas termostatizadas acopladas y DTPA como agente complejante

    Energy Technology Data Exchange (ETDEWEB)

    Vite T, J.; Vite T, M.; Guerrero D, J.; Carreno de Leon, M.C. [Departamento de Estudios del Ambiente, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    We studied the metallic composition from waste water sludge and incinerators ashes of an incinerator located in Toluca, Mexico, the qualitative studies were made using the Activation Analysis technique, and fluorescence X-ray techniques. The quantitative analysis of heavy metals in the wastes were made using Inductively coupled plasma atomic emission spectrometry (Icp-Aes). For leaching the samples, we used four coupled thermostated columns, each one had a p H of 2,5, 7 and 10. The flux of the air was of 1600 cc/min. The temperature was maintain constant in 60 Centigrade using a thermostated system. For this study we used 100 g of wastes mixed with mineral acid or sodium hydroxide to reach p H 2,5,7 and 10. We added a reducing and tensoactive agents and finally DTPA as complex agent. With this method, we obtain a better leaching efficiency using a complex agent. However the high DTPA cost, make this process expansive that is why we recommend to work with another classes of complex agents, that be cheaper to leach metals of different chemistry matrix. (Author)

  4. Technological and energetic improvement of a propylene distillation column

    Directory of Open Access Journals (Sweden)

    Ostrovski Nikolaj

    2005-01-01

    Full Text Available A multicomponent distillation column for propylene purification was optimized in order to increase its energetic effectively. The ©-method coupled with the Soave-Redlich-Kwong equation of state for generating K-values and enthalpies was used. The optimal combination of pressure, temperature and reflux flow provided the decrease of steam consumption and loss of propylene with bottom flow.

  5. Column-Oriented Database Systems (Tutorial)

    NARCIS (Netherlands)

    D. Abadi; P.A. Boncz (Peter); S. Harizopoulos

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as

  6. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  7. Behavior of Confined Columns under Different Techniques

    OpenAIRE

    Mostafa Osman; Ata El-Kareim Shoeib Soliman

    2015-01-01

    Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced concrete (RC) columns with different types of techniques are assessment. And also,...

  8. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  9. Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Junior, Ademario I da Silva; Marriott, Philip J

    2018-02-09

    A pressure tunable (PT) coupled column ensemble has been implemented for the second dimension ( 2 D) separation in comprehensive two dimensional gas chromatography (GC×PTGC). This process requires two columns to be connected by a pressure junction, as a replacement for a single narrow bore, short column in 2 D. Various 2 D 1 and 2 D 2 columns may be selected to provide complementary selectivity (polarity) compared to the 1 D column. The tunable residence time arising from differential pressure drop in each 2 D column results in a tunable fractional contribution of each column in the 2 D separation. A sample mixture comprising different chemical classes, including alkanes and alcohols, is used to identify the feasibility and extent of selectivity tuning possible in GC×PTGC. The column length is also varied due to the imposed challenge of wraparound in the PT coupled column system as pressures are adjusted in the 2 D separation. Different experimental parameters, stationary phase materials and column lengths have been applied to investigate and understand the separation behaviour of the 2 D PT coupled column GC×GC system. Results are discussed considering analyte retention time, peak width, linear velocity and the contribution of each 2 D column. A specific and unexpected example of GC×GC separation was demonstrated where the peak positions of polar and apolar compounds could almost swap their 2 D retention position by application of PT. Kerosene was analysed as an example of complex sample analysis by GC×PTGC system. This process is shown to be a practical approach for altering different stationary phase selectivities in a single 2 D arrangement in GC×GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Radiotracer Imaging of Sediment Columns

    Science.gov (United States)

    Moses, W. W.; O'Neil, J. P.; Boutchko, R.; Nico, P. S.; Druhan, J. L.; Vandehey, N. T.

    2010-12-01

    Nuclear medical PET and SPECT cameras routinely image radioactivity concentration of gamma ray emitting isotopes (PET - 511 keV; SPECT - 75-300 keV). We have used nuclear medical imaging technology to study contaminant transport in sediment columns. Specifically, we use Tc-99m (T1/2 = 6 h, Eγ = 140 keV) and a SPECT camera to image the bacteria mediated reduction of pertechnetate, [Tc(VII)O4]- + Fe(II) → Tc(IV)O2 + Fe(III). A 45 mL bolus of Tc-99m (32 mCi) labeled sodium pertechnetate was infused into a column (35cm x 10cm Ø) containing uranium-contaminated subsurface sediment from the Rifle, CO site. A flow rate of 1.25 ml/min of artificial groundwater was maintained in the column. Using a GE Millennium VG camera, we imaged the column for 12 hours, acquiring 44 frames. As the microbes in the sediment were inactive, we expected most of the iron to be Fe(III). The images were consistent with this hypothesis, and the Tc-99m pertechnetate acted like a conservative tracer. Virtually no binding of the Tc-99m was observed, and while the bolus of activity propagated fairly uniformly through the column, some inhomogeneity attributed to sediment packing was observed. We expect that after augmentation by acetate, the bacteria will metabolically reduce Fe(III) to Fe(II), leading to significant Tc-99m binding. Imaging sediment columns using nuclear medicine techniques has many attractive features. Trace quantities of the radiolabeled compounds are used (micro- to nano- molar) and the half-lives of many of these tracers are short (Image of Tc-99m distribution in a column containing Rifle sediment at four times.

  11. Performance evaluation of a rectifier column using gamma column scanning

    Directory of Open Access Journals (Sweden)

    Aquino Denis D.

    2017-12-01

    Full Text Available Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.

  12. Coupled buckling design of steel laced columns | Uziak | Botswana ...

    African Journals Online (AJOL)

    A new design method developed by the authors that gives an opportunity to account for the interaction of different modes of buckling is presented. Eurocode 3 model is used as the reference model. In the reference model, an equivalent geometric imperfection comprising of an initial bow being equal to the length divided by ...

  13. Benzene degradation coupled with chlorate reduction in soil column study

    NARCIS (Netherlands)

    Tan, N.C.G.; Doesburg, van W.C.J.; Langenhoff, A.A.M.; Stams, A.J.M.

    2006-01-01

    Perchlorate and chlorate are electron acceptors that during reduction result in the formation of molecular oxygen. The produced oxygen can be used for activation of anaerobic persistent pollutants, like benzene. In this study chlorate was tested as potential electron acceptor to stimulate benzene

  14. Avaliação da libertação de azoto a partir de correctivos orgânicos utilizando membranas de troca aniónica e um medidor de clorofila SPAD-502 Nitrogen release from organic amendments assessed by using anion exchange membranes and the SPAD-502 chlorophyll meter

    Directory of Open Access Journals (Sweden)

    A. Pereira

    2009-01-01

    senescência por falta de azoto.Results from pot experiments where anion exchange membranes (MTA were inserted into the soil to monitor soil nitrate levels over time, and the plant N nutritional status assessed with a SPAD-502 chlorophyll meter, are reported in this work. Maize was grown in the summer season and turnip and rye in the winter period. Maize was sown on June 5, 2004, and turnip and rye on September 23, 2004. The plants were subjected to the following treatments: Nutrisoil (Nut; Beiraadubo (Bei; Phenix (Phe; Vegethumus (Veg; cow manure (EB; chestnut fruit bark (CC; ammonium nitrate (NA; and control treatment, without N fertilization (T. Two weeks after the maize was sown, soil nitrate levels extracted by MTA ranged between 18.9 and 239.0 mg L-1 in the CC and Bei treatments, respectively. In the first week of August mean soil nitrate values ranged between 12.9 and 52.3 mg L-1 in the CC and Bei treatments. In September, the last sampling date, mean soil nitrate levels were found to be in the range of 9.7 and 67.9 mg L-1 in the CC and Nut treatments. Relationships between MTA and SPAD results with dry matter yield and N uptake were established. The MTA were able to differentiate well as the organic amendments released their N during the season and this aspect influenced N uptake and plant growth. SPAD readings were also a good index of plant N nutritional status. SPAD values were linearly related with dry matter yield and N uptake. In this study, where the pots were managed to avoid nitrate leaching and denitrification, winter grown species recovered the residual N of maize fertilization. At the end of experiment the plants showed senescent leaves with deep N deficiency symptoms.

  15. Bubble columns : Structures or stability?

    NARCIS (Netherlands)

    Harteveld, W.K.

    2005-01-01

    The aim of the thesis is to contribute to the understanding of the hydrodynamics of the gravity driven bubbly flow that can be found in bubble columns. Special attention is paid to the large scale structures that have a strong impact on several key parameters such as the degree of mixing, mass and

  16. Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation.

    Science.gov (United States)

    Lestremau, François; Wu, Di; Szücs, Roman

    2010-07-23

    The present study focuses on the evaluation of 1.0 mm i.d. (internal diameter) columns on a commercial Ultra-High Pressure system. These systems have been developed specifically to operate columns with small volumes, typically 2.1 mm i.d., by reducing extra-column volume dispersion. The use of columns with smaller i.d. results in a reduced solvent consumption and required sample volume. The evaluation of the columns was carried out with samples containing neutral and pharmaceutical compounds. In isocratic mode, the extra-column volume produced additional band broadening leading to poor performances compared to equivalent 2.1 mm i.d. columns. By increasing the length of the column, the influence of the extra-column bandspreading could be reduced and 75,000 plates were obtained when four columns were coupled. In gradient mode, the effect of the extra-column contribution on efficiency was limited and about 80% of the performance of the 2.1 mm i.d. columns was obtained. Optimum conditions in gradient mode were further investigated by changing flow rate, gradient time and column length. A different approach of the calculation of peak capacity was also considered for the comparison of the influence of these different parameters. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  17. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  18. Temperature programmable microfabricated gas chromatography column

    Science.gov (United States)

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  19. 29 CFR 1926.755 - Column anchorage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Column anchorage. 1926.755 Section 1926.755 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a) General requirements for erection stability. (1) All columns shall be anchored by a minimum of 4 anchor...

  20. Coupled transfers; Transferts couples

    Energy Technology Data Exchange (ETDEWEB)

    Nicolas, X.; Lauriat, G.; Jimenez-Rondan, J. [Universite de Marne-la-Vallee, Lab. d' Etudes des Transferts d' Energie et de Matiere (LETEM), 77 (France); Bouali, H.; Mezrhab, A. [Faculte des Sciences, Dept. de Physique, Lab. de Mecanique et Energetique, Oujda (Morocco); Abid, C. [Ecole Polytechnique Universitaire de Marseille, IUSTI UMR 6595, 13 Marseille (France); Stoian, M.; Rebay, M.; Lachi, M.; Padet, J. [Faculte des Sciences, Lab. de Thermomecanique, UTAP, 51 - Reims (France); Mladin, E.C. [Universitaire Polytechnique Bucarest, Faculte de Genie Mecanique, Bucarest (Romania); Mezrhab, A. [Faculte des Sciences, Lab. de Mecanique et Energetique, Dept. de Physique, Oujda (Morocco); Abid, C.; Papini, F. [Ecole Polytechnique, IUSTI, 13 - Marseille (France); Lorrette, C.; Goyheneche, J.M.; Boechat, C.; Pailler, R. [Laboratoire des Composites ThermoStructuraux, UMR 5801, 33 - Pessac (France); Ben Salah, M.; Askri, F.; Jemni, A.; Ben Nasrallah, S. [Ecole Nationale d' Ingenieurs de Monastir, Lab. d' Etudes des Systemes Thermiques et Energetiques (Tunisia); Grine, A.; Desmons, J.Y.; Harmand, S. [Laboratoire de Mecanique et d' Energetique, 59 - Valenciennes (France); Radenac, E.; Gressier, J.; Millan, P. [ONERA, 31 - Toulouse (France); Giovannini, A. [Institut de Mecanique des Fluides de Toulouse, 31 (France)

    2005-07-01

    This session about coupled transfers gathers 30 articles dealing with: numerical study of coupled heat transfers inside an alveolar wall; natural convection/radiant heat transfer coupling inside a plugged and ventilated chimney; finite-volume modeling of the convection-conduction coupling in non-stationary regime; numerical study of the natural convection/radiant heat transfer coupling inside a partitioned cavity; modeling of the thermal conductivity of textile reinforced composites: finite element homogenization on a full periodical pattern; application of the control volume method based on non-structured finite elements to the problems of axisymmetrical radiant heat transfers in any geometries; modeling of convective transfers in transient regime on a flat plate; a conservative method for the non-stationary coupling of aero-thermal engineering codes; measurement of coupled heat transfers (forced convection/radiant transfer) inside an horizontal duct; numerical simulation of the combustion of a water-oil emulsion droplet; numerical simulation study of heat and mass transfers inside a reactor for nano-powders synthesis; reduction of a combustion and heat transfer model of a direct injection diesel engine; modeling of heat transfers inside a knocking operated spark ignition engine; heat loss inside an internal combustion engine, thermodynamical and flamelet model, composition effects of CH{sub 4}H{sub 2} mixtures; experimental study and modeling of the evolution of a flame on a solid fuel; heat transfer for laminar subsonic jet of oxygen plasma impacting an obstacle; hydrogen transport through a A-Si:H layer submitted to an hydrogen plasma: temperature effects; thermal modeling of the CO{sub 2} laser welding of a magnesium alloy; radiant heat transfer inside a 3-D environment: application of the finite volume method in association with the CK model; optimization of the infrared baking of two types of powder paints; optimization of the emission power of an infrared

  1. Axisymmetric collapses of granular columns

    Science.gov (United States)

    Lube, Gert; Huppert, Herbert E.; Sparks, R. Stephen J.; Hallworth, Mark A.

    2004-06-01

    Experimental observations of the collapse of initially vertical columns of small grains are presented. The experiments were performed mainly with dry grains of salt or sand, with some additional experiments using couscous, sugar or rice. Some of the experimental flows were analysed using high-speed video. There are three different flow regimes, dependent on the value of the aspect ratio a {=} h_i/r_i, where h_i and r_i are the initial height and radius of the granular column respectively. The differing forms of flow behaviour are described for each regime. In all cases a central, conically sided region of angle approximately 59(°) , corresponding to an aspect ratio of 1.7, remains undisturbed throughout the motion. The main experimental results for the final extent of the deposit and the time for emplacement are systematically collapsed in a quantitative way independent of any friction coefficients. Along with the kinematic data for the rate of spread of the front of the collapsing column, this is interpreted as indicating that frictional effects between individual grains in the bulk of the moving flow only play a role in the last instant of the flow, as it comes to an abrupt halt. For a {reach r_infty is given by t_infty {=} 3(h_i/g)(1/2} {=} 3(r_i/g)({1/2}a^{1/2)) , where g is the gravitational acceleration. The insights and conclusions gained from these experiments can be applied to a wide range of industrial and natural flows of concentrated particles. For example, the observation of the rapid deposition of the grains can help explain details of the emplacement of pyroclastic flows resulting from the explosive eruption of volcanoes.

  2. The fractionation of dinucleoside monophosphate and some trinucleoside diphosphate isonicotinoyl hydrazones by column chromatography

    Science.gov (United States)

    Hunt, John A.

    1970-01-01

    A column-chromatographic system using DEAE-cellulose and gradient elution with triethylammonium formate at pH4.0–3.5 is described. It is capable of separating the oligonucleotide isonicotinoyl hydrazones that are produced by nuclease digestion of RNA oxidized with periodate and coupled with isonicotinic acid hydrazide. Fifteen dinucleoside monophosphate isonicotinoyl hydrazones were characterized by their elution positions on the columns, so that all but two of them could readily be identified. Twelve trinucleoside diphosphate hydrazones were also characterized by their elution positions on the column. The application of this method of fractionation to terminal-sequence studies of RNA is discussed. PMID:5414095

  3. Study on Fluid-Induced Vibration Power Harvesting of Square Columns under Different Attack Angles

    Directory of Open Access Journals (Sweden)

    Meng Zhang

    2017-01-01

    Full Text Available A model of the flow-vibration-electrical circuit multiphysical coupling system for solving square column vortex-induced vibration piezoelectric energy harvesting (VIVPEH is proposed in this paper. The quasi steady state theory is adopted to describe the fluid solid coupling process of vortex-induced vibration based on the finite volume method coupled Gauss equation. The vibrational response and the quasi steady state form of the output voltage are solved by means of the matrix coefficient method and interactive computing. The results show that attack angles play an important role in the performance of square column VIVPEH, of which α=45° is a relatively ideal attack angle of square column VIVPEH.

  4. Alumina column Rb-82 generator

    International Nuclear Information System (INIS)

    Yano, Y.; Roth, E.P.

    1977-10-01

    The use of an alumina column for the adsorption of radioactive Sr for the generator production of 75-sec 82 Rb was evaluated in both batches and column experiments using 85 Sr and cyclotron-produced 82 Sr. Comparisons of alumina, Bio-Rex 70 and Chelex 100 ion exchangers were made to determine Sr adsorption, 82 Rb elution yield and Sr breakthrough. The adsorption of Sr is similar for alumina and Chelex 100 but different for Bio-Rex 70. Alumina and Chelex 100 exhibit a small fraction of poorly bound Sr which appears as higher breakthrough in the early elution volumes. The remaining Sr activity is strongly bound to these ion exchangers and the breakthrough remains stable at a lower breakthrough value through a large number of elutions. Bio-Rex 70 on the other hand does not exhibit the poorly bound Sr fraction and the breakthrough of Sr remains the lowest of the three ion exchangers through a moderate number of elutions and then the Sr breakthrough gradually increases with each additional elution

  5. Separation of seven arsenic compounds by high performance liquid chromatography with on-line detection by hydrogen-argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, Erik Huusfeldt; Pritzl, G.

    1992-01-01

    the HPLC column to the nebulizer of the atomic absorption spectrometer. Arsenite, arsenate, monomethylarsonate (MMA) and dimethylarsinate (DMA) were separated from each other and from the co-injected cationic arsenic compounds, arsenobetaine (AsB), arsenocholine (AsC) and the tetramethylarsonium ion (TMAs......) on an organic polymeric anion-exchange column with 0.1 mol dm-3 carbonate at pH 10.3 as the mobile phase. The three cationic species were separated from each other and from the co-injected anionic species on a silica based cation-exchange column with pyridine at a pH of 2.65 as the mobile phase. The signal...... of mixtures of arsenic standards into the HPLC system were: arsenite, As(III) 1.1; arsenate, As(V) 1.4; MMA 1.4; DMA 0.7; AsB 0.3; AsC 0.5; and the TMAs 0.4. The HPLC-AAS system was used for the analysis of arsenic species in aqueous extracts of soil samples from a polluted land site. Only arsenate was found...

  6. Cross-column prediction of gas-chromatographic retention of polybrominated diphenyl ethers.

    Science.gov (United States)

    D'Archivio, Angelo Antonio; Giannitto, Andrea; Maggi, Maria Anna

    2013-07-12

    In this paper, we predict the retention of polybrominated diphenyl ethers (PBDEs) in capillary gas-chromatography (GC) within a useful range of separation conditions. In a first stage of this study, quantitative structure-retention relationships (QSRRs) of PBDEs in six stationary phases with different polarity are established. The single-column QSRR models are generated using the retention data of 126 PBDE congeners by multilinear regression (MLR) coupled to genetic algorithm variable selection applied to a large set of theoretical molecular descriptors of different classes. A quite accurate fitting of experimental retentions is obtained for each of the six GC columns adopting five molecular descriptors. In a further step of this work six molecular descriptors were extracted within the set of molecular descriptors (17 variables) involved in the various single-column QSRRs. The selected molecular descriptors are combined with observed retentions of ten representative PBDEs, adopted as descriptors of the GC system. These quantities are considered as the independent variables of a multiple-column retention model able to simultaneously relate GC retention to PBDE molecular structure and kind of column. The quantitative structure/column-retention relationship is established using a multi-layer artificial neural network (ANN) as regression tool. To optimise the ANN model, a validation set is generated by selecting two out of the six calibration columns. Splitting of columns between training and validation sets, as well as selection of PBDE congeners to be used as column descriptors, is performed with the help of a principal component analysis on the retention data. Cross-column predictive performance of the final model is tested on a large external set consisting of retention data of 180 PBDEs collected in four separation conditions different from those considered in model calibration (different columns and/or temperature program). Copyright © 2013 Elsevier B.V. All

  7. Evaluation of Packed Distillation Columns I - Atmospheric Pressure

    National Research Council Canada - National Science Library

    Reynolds, Thaine

    1951-01-01

    .... Four column-packing combinations of the glass columns and four column-packing combinations of the steel columns were investigated at atmospheric pressure using a test mixture of methylcyclohexane...

  8. Oscillating water column structural model

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Guild [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bull, Diana L [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jepsen, Richard Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gordon, Margaret Ellen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    An oscillating water column (OWC) wave energy converter is a structure with an opening to the ocean below the free surface, i.e. a structure with a moonpool. Two structural models for a non-axisymmetric terminator design OWC, the Backward Bent Duct Buoy (BBDB) are discussed in this report. The results of this structural model design study are intended to inform experiments and modeling underway in support of the U.S. Department of Energy (DOE) initiated Reference Model Project (RMP). A detailed design developed by Re Vision Consulting used stiffeners and girders to stabilize the structure against the hydrostatic loads experienced by a BBDB device. Additional support plates were added to this structure to account for loads arising from the mooring line attachment points. A simplified structure was designed in a modular fashion. This simplified design allows easy alterations to the buoyancy chambers and uncomplicated analysis of resulting changes in buoyancy.

  9. REDISTRIBUTOR FOR LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Bradley, J.G.

    1957-10-29

    An improved baffle plate construction to intimately mix immiscible liquid solvents for solvent extraction processes in a liquid-liquid pulse column is described. To prevent the light and heavy liquids from forming separate continuous homogeneous vertical channels through sections of the column, a baffle having radially placed rectangular louvers with deflection plates opening upon alternate sides of the baffle is placed in the column, normal to the axis. This improvement substantially completely reduces strippiig losses due to poor mixing.

  10. Structural design of isolated column footings

    Directory of Open Access Journals (Sweden)

    Fathi Abdrabbo

    2016-09-01

    The study showed that shear span to depth ratio of a footing and distributions of contact stress at footing–soil interface are key factors in the structural design of the footing. ECP203-11, ACI318-08, and EC2-2004 code provisions, underestimate the structural failure loads of isolated column footings, while BS 8110.1-1997 overpredicts the failure loads of isolated column footings, if punching provisions at perimeter of column are pulled out from the code.

  11. Thermally stable dexsil-400 glass capillary columns

    International Nuclear Information System (INIS)

    Maskarinec, M.P.; Olerich, G.

    1980-01-01

    The factors affecting efficiency, thermal stability, and reproducibility of Dexsil-400 glass capillary columns for gas chromatography in general, and for polycyclic aromatic hydrocarbons (PAHs) in particular were investigated. Columns were drawn from Kimble KG-6 (soda-lime) glass or Kimox (borosilicate) glass. All silylation was carried out at 200 0 C. Columns were coated according to the static method. Freshly prepared, degassed solutions of Dexsil-400 in pentane or methylene chloride were used. Thermal stability of the Dexsil 400 columns with respect to gas chromatography/mass spectrometry (GC/MS) were tested. Column-to-column variability is a function of each step in the fabrication of the columns. The degree of etching, extent of silylation, and stationary phase film thickness must be carefully controlled. The variability in two Dexsil-400 capillary column prepared by etching, silylation with solution of hexa methyl disilazone (HMDS), and static coating is shown and also indicates the excellent selectivity of Dexsil-400 for the separation of alkylated aromatic compounds. The wide temperature range of Dexsil-400 and the high efficiency of the capillary columns also allow the analysis of complex mixtures with minimal prefractionation. Direct injection of a coal liquefaction product is given. Analysis by GC/MS indicated the presence of parent PAHs, alkylated PAHs, nitrogen and sulfur heterocycles, and their alkylated derivatives. 4 figures

  12. Preparation and application of hydrophilic monolithic columns.

    Science.gov (United States)

    Jiang, Zhengjin; Smith, Norman William; Liu, Zhenghua

    2011-04-29

    Hydrophilic interaction chromatography (HILIC) has experienced increasing attention in recent years. Much research has been carried out in the area of HILIC separation mechanisms, column techniques and applications. Because of their good permeability, low resistance to mass transfer and easy preparation within capillaries, hydrophilic monolithic columns represent a trend among novel HILIC column techniques. This review attempts to present an overview of the preparation and applications of HILIC monolithic columns carried out in the past decade. The separation mechanism of various hydrophilic monolithic stationary phases is also reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Gaseous carbon dioxide absorbing column

    International Nuclear Information System (INIS)

    Harashina, Heihachi.

    1994-01-01

    The absorbing column of the present invention comprises a cyclone to which CO 2 gas and Ca(OH) 2 are blown to form CaCO 3 , a water supply means connected to an upper portion of the cyclone for forming a thin water membrane on the inner wall thereof, and a water processing means connected to a lower portion of the cyclone for draining water incorporating CaCO 3 . If a mixed fluid of CO 2 gas and Ca(OH) 2 is blown in a state where a flowing water membrane is formed on the inner wall of the cyclone, formation of CaCO 3 is promoted also in the inside of the cyclone in addition to the formation of CaCO 3 in the course of blowing. Then, formed CaCO 3 is discharged from the lower portion of the cyclone together with downwardly flowing water. With such procedures, solid contents such as CaCO 3 separated at the inner circumferential wall are sent into the thin water membrane, adsorbed and captured, and the solid contents are successively washed out, so that a phenomenon that the solid contents deposit and grow on the inner wall of the cyclone can be prevented effectively. (T.M.)

  14. Column: Factors Affecting Data Decay

    Directory of Open Access Journals (Sweden)

    Kevin Fairbanks

    2012-06-01

    Full Text Available In nuclear physics, the phrase decay rate is used to denote the rate that atoms and other particles spontaneously decompose. Uranium-235 famously decays into a variety of daughter isotopes including Thorium and Neptunium, which themselves decay to others. Decay rates are widely observed and wildly different depending on many factors, both internal and external. U-235 has a half-life of 703,800,000 years, for example, while free neutrons have a half-life of 611 seconds and neutrons in an atomic nucleus are stable.We posit that data in computer systems also experiences some kind of statistical decay process and thus also has a discernible decay rate. Like atomic decay, data decay fluctuates wildly. But unlike atomic decay, data decay rates are the result of so many different interplaying processes that we currently do not understand them well enough to come up with quantifiable numbers. Nevertheless, we believe that it is useful to discuss some of the factors that impact the data decay rate, for these factors frequently determine whether useful data about a subject can be recovered by forensic investigation.(see PDF for full column

  15. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  16. The general packed column : an analytical solution

    NARCIS (Netherlands)

    Gielen, J.L.W.

    2000-01-01

    The transient behaviour of a packed column is considered. The column, uniformly packed on a macroscopic scale, is multi-structured on the microscopic level: the solid phase consists of particles, which may differ in incidence, shape or size, and other relevant physical properties. Transport in the

  17. Interaction Buckling Experiments of Box columns

    OpenAIRE

    永藤, 寿宮

    1988-01-01

    Box sections present very interesting properties in the field of compressed elements. The purpose of this experiment is to supply experimental data of interaction buckling (overall and local buckling). Test columns are classified into 4 types according to those columns length. Support conditions are pin-ended type by using new developed bowl shoe.

  18. Fringing-field effects in acceleration columns

    International Nuclear Information System (INIS)

    Yavor, M.I.; Weick, H.; Wollnik, H.

    1999-01-01

    Fringing-field effects in acceleration columns are investigated, based on the fringing-field integral method. Transfer matrices at the effective boundaries of the acceleration column are obtained, as well as the general transfer matrix of the region separating two homogeneous electrostatic fields with different field strengths. The accuracy of the fringing-field integral method is investigated

  19. Center column design of the PLT

    International Nuclear Information System (INIS)

    Citrolo, J.; Frankenberg, J.

    1975-01-01

    The center column of the PLT machine is a secondary support member for the toroidal field coils. Its purpose is to decrease the bending moment at the nose of the coils. The center column design was to have been a stainless steel casting with the toroidal field coils grouped around the casting at installation, trapping it in place. However, the castings developed cracks during fabrication and were unsuitable for use. Installation of the coils proceeded without the center column. It then became necessary to redesign a center column which would be capable of installation with the toroidal field coils in place. The final design consists of three A-286 forgings. This paper discusses the final center column design and the influence that new knowledge, obtained during the power tests, had on the new design

  20. Three-dimensional motion pattern of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.

    Science.gov (United States)

    Benninger, Monika I; Seiler, Gabriela S; Robinson, Leanne E; Ferguson, Stephen J; Bonél, Harald M; Busato, André R; Lang, Johann

    2004-05-01

    To evaluate the 3-dimensional motion pattern including main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column of dogs. Vertebral columns of 9 German Shepherd Dogs (GSDs) and 16 dogs of other breeds with similar body weights and body conditions. Main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column (L4 to S1) were determined by use of a testing apparatus that permitted precise application of known pure moments to the vertebral column. Motion was compared between GSDs and dogs of other breeds. All specimens had a similar motion pattern consisting of main motion and a certain amount of coupled motion including translation. Vertebral columns of GSDs had significantly less main motion in all directions than that of dogs of other breeds. Translation was similar in GSDs and dogs of other breeds and was smallest at the lumbosacral motion segment. Results indicated that motion in the caudal lumbar and lumbosacral portions of the vertebral column of dogs is complex and provided a basis for further studies evaluating abnormal vertebral columns.